NSCRTV-HFCEMS-OPTICALTRANSMITTERDIRECTLY-MIB DEFINITIONS ::= BEGIN
|
||
-- *****************************************************************************
|
||
-- 附录H 直接调制光发射机MIB
|
||
-- *****************************************************************************
|
||
|
||
IMPORTS
|
||
OBJECT-TYPE
|
||
FROM RFC-1212
|
||
DisplayString
|
||
FROM RFC1213-MIB
|
||
otdIdent
|
||
FROM NSCRTV-ROOT;
|
||
|
||
otdVendorOID OBJECT-TYPE
|
||
SYNTAX OBJECT IDENTIFIER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"此对象提供厂商对直接调制光发送机MIB的扩充,无扩充时此对象应指向直接调制光发送
|
||
机节点otdIdent。"
|
||
::= { otdIdent 1 }
|
||
|
||
otdSlotNumber OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"下行光发送机数量或机架插槽数量。"
|
||
::= { otdIdent 2 }
|
||
|
||
otdOptDeviceTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF OtdOptDeviceEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"下行光发送机信息表。"
|
||
::= { otdIdent 3 }
|
||
|
||
otdOptDeviceEntry OBJECT-TYPE
|
||
SYNTAX OtdOptDeviceEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"下行光发送机信息表目。"
|
||
INDEX { otdIndex }
|
||
::= { otdOptDeviceTable 1 }
|
||
|
||
OtdOptDeviceEntry ::= SEQUENCE
|
||
{
|
||
otdIndex
|
||
INTEGER,
|
||
otdLaserWavelength
|
||
DisplayString,
|
||
otdLaserType
|
||
DisplayString,
|
||
otdDriveLevel
|
||
INTEGER,
|
||
otdInputRFLevel
|
||
INTEGER,
|
||
otdInputRFAttenuationRange
|
||
INTEGER,
|
||
otdInputRFAttenuation
|
||
INTEGER,
|
||
otdLaserTemp
|
||
INTEGER,
|
||
otdLaserCurrent
|
||
INTEGER,
|
||
otdOpicalOutputPower
|
||
INTEGER,
|
||
otdTecCurrent
|
||
INTEGER,
|
||
otdAGCControl
|
||
INTEGER,
|
||
otdConfigurationDriveLevel
|
||
INTEGER,
|
||
otdConfigurationRFAttenuation
|
||
INTEGER,
|
||
otdConfigurationRFChannels
|
||
INTEGER
|
||
}
|
||
|
||
|
||
otdIndex OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"下行光发送机索引,可以是光发送机编号或机架插槽号。"
|
||
::= { otdOptDeviceEntry 1 }
|
||
|
||
otdLaserWavelength OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"激光器波长。"
|
||
::= { otdOptDeviceEntry 2 }
|
||
|
||
otdLaserType OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"激光器类型,有效值为unisolated FP, isolated FP, uncooled DFB, cooled DFB,ITU
|
||
等。"
|
||
::= { otdOptDeviceEntry 3 }
|
||
|
||
otdDriveLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127 )
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"光模块激励电平,单位为dBuV/ch。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 4 }
|
||
|
||
otdInputRFLevel OBJECT-TYPE
|
||
SYNTAX INTEGER (0..127 )
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"输入射频信号电平,单位为dBuV/ch。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 5 }
|
||
|
||
otdInputRFAttenuationRange OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..32767 )
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"输入射频信号衰减量范围,单位为0.1dB。"
|
||
::= { otdOptDeviceEntry 6 }
|
||
|
||
otdInputRFAttenuation OBJECT-TYPE
|
||
SYNTAX INTEGER ( -32768..32767 )
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"输入射频信号衰减量,单位为0.1dB。"
|
||
::= { otdOptDeviceEntry 7 }
|
||
|
||
otdLaserTemp OBJECT-TYPE
|
||
SYNTAX INTEGER ( -32768..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"激光器工作温度,单位为0.1摄氏度。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 8 }
|
||
|
||
otdLaserCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER (-32768..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"激光器工作电流,单位为0.1mA。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 9 }
|
||
|
||
otdOpicalOutputPower OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"输出光功率,单位为0.1mW。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 10 }
|
||
|
||
otdTecCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER ( -32768..32767 )
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"激光器制冷电流,单位为0.01A。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdOptDeviceEntry 11 }
|
||
|
||
otdAGCControl OBJECT-TYPE
|
||
SYNTAX INTEGER {off(1),on(2)}
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"AGC控制使能。"
|
||
::= { otdOptDeviceEntry 12 }
|
||
|
||
otdConfigurationDriveLevel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"设定激光器RF驱动电平偏移量,单位为0.1dB。该参数仅在AGC模式为打开时起作用。
|
||
系统根据该设定自动调整RF增益(衰减),从而达到设定的激光器RF驱动电平偏移量。
|
||
"
|
||
::= { otdOptDeviceEntry 13 }
|
||
|
||
otdConfigurationRFAttenuation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"设定激光器RF驱动信号增益(衰减)的偏移量,单位为0.1dB。该参数仅在AGC模式为
|
||
关闭时起作用(MGC)。系统根据该设定调整RF信道的增益(衰减),从而达到手动
|
||
控制激光器RF驱动电平的目的。"
|
||
::= { otdOptDeviceEntry 14 }
|
||
|
||
otdConfigurationRFChannels OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"RF信号中输入的电视信号频道数。"
|
||
::= { otdOptDeviceEntry 15 }
|
||
|
||
otdFansNumber OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"表示内部散热风扇的数量,'0'表示设备不支持散热风扇的监测或没有散热风扇。"
|
||
::= { otdIdent 4 }
|
||
|
||
otdFansTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF OtdFansEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇信息表。"
|
||
::= { otdIdent 5 }
|
||
|
||
otdFansEntry OBJECT-TYPE
|
||
SYNTAX OtdFansEntry
|
||
ACCESS not-accessible
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇信息表目。"
|
||
INDEX { otdFansIndex }
|
||
::= { otdFansTable 1 }
|
||
|
||
OtdFansEntry ::= SEQUENCE {
|
||
otdFansIndex
|
||
INTEGER,
|
||
otdFansState
|
||
INTEGER,
|
||
otdFansSpeed
|
||
INTEGER,
|
||
otdFansControl
|
||
INTEGER,
|
||
otdFansName
|
||
DisplayString
|
||
}
|
||
|
||
|
||
otdFansIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇信息表索引。"
|
||
::= { otdFansEntry 1 }
|
||
|
||
otdFansState OBJECT-TYPE
|
||
SYNTAX INTEGER {normal (1), fault (2), off (3) }
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇工作状态,normal 表示正常,fault表示失效,off表示关闭。此对象要求在离散属性MIB中登
|
||
记一个条目。"
|
||
::= { otdFansEntry 2 }
|
||
|
||
otdFansSpeed OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇工作时的转速,单位为转/分,不支持转速检测时可置为'0'。此对象要求在
|
||
离散属性MIB中登记一个条目。"
|
||
::= { otdFansEntry 3 }
|
||
|
||
otdFansControl OBJECT-TYPE
|
||
SYNTAX INTEGER { on(1), off(2) }
|
||
ACCESS read-write
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇工作控制。 "
|
||
::= { otdFansEntry 4 }
|
||
|
||
otdFansName OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"散热风扇名称。"
|
||
::= { otdFansEntry 5 }
|
||
|
||
--*
|
||
--* 直流电源
|
||
--*
|
||
otdNumberDCPowerSupply OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..16 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"直流电源数量,'0'表示应答器不支持此功能。"
|
||
::= { otdIdent 6 }
|
||
|
||
otdDCPowerSupplyMode OBJECT-TYPE
|
||
SYNTAX INTEGER { loadsharing(1), switchedredundant(2),alonesupply(3) }
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"供电电源工作模式。"
|
||
::= { otdIdent 7 }
|
||
|
||
otdDCPowerTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF OtdDCPowerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"直流电源信息表。"
|
||
::= { otdIdent 8 }
|
||
|
||
otdDCPowerEntry OBJECT-TYPE
|
||
SYNTAX OtdDCPowerEntry
|
||
ACCESS not-accessible
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"直流电源信息表目。"
|
||
INDEX { otdDCPowerIndex }
|
||
::= { otdDCPowerTable 1 }
|
||
|
||
OtdDCPowerEntry ::= SEQUENCE
|
||
{
|
||
otdDCPowerIndex
|
||
INTEGER,
|
||
otdDCPowerVoltage
|
||
INTEGER,
|
||
otdDCPowerCurrent
|
||
INTEGER,
|
||
otdDCPowerName
|
||
DisplayString
|
||
}
|
||
|
||
otdDCPowerIndex OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"直流电源索引。"
|
||
::= { otdDCPowerEntry 1 }
|
||
|
||
otdDCPowerVoltage OBJECT-TYPE
|
||
SYNTAX INTEGER (-32768..32767 )
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"电源电压,单位为0.1V。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdDCPowerEntry 2 }
|
||
|
||
otdDCPowerCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER ( 0..65535 )
|
||
ACCESS read-only
|
||
STATUS optional
|
||
DESCRIPTION
|
||
"电源电流,单位为0.1A。此对象要求在属性MIB中登记一个条目。"
|
||
::= { otdDCPowerEntry 3 }
|
||
|
||
otdDCPowerName OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
ACCESS read-only
|
||
STATUS mandatory
|
||
DESCRIPTION
|
||
"标明电源的名称,例如:24V直流电源。
|
||
此字段值由用户规定,至少应标明工作电压并将多个电源相互区分开。
|
||
当表中的对象产生告警时,此对象名称应放进hfcAlarmEvent陷阱的alarmText对象里(见
|
||
附录D)。"
|
||
::= { otdDCPowerEntry 4 }
|
||
|
||
-- *****************************************************************************
|
||
END |