mibs/MIBS/hp/HP-SwitchStack-MIB
2023-12-05 12:25:34 +01:00

524 lines
20 KiB
Plaintext

HP-SwitchStack-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Integer32, IpAddress
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
RowStatus, MacAddress
FROM SNMPv2-TC
hpSwitch
FROM HP-ICF-OID;
hpSwitchVirtualStackMib MODULE-IDENTITY
LAST-UPDATED "200011032344Z" -- November 3, 2000
ORGANIZATION "Hewlett Packard Company,
Network Infrastructure Solutions"
CONTACT-INFO "Hewlett Packard Company
8000 Foothills Blvd.
Roseville, CA 95747"
DESCRIPTION "This MIB module describes objects for managing
the Stacking features of devices in the HP
Integrated Communication Facility product line."
REVISION "200011032344Z" -- November 3, 2000
DESCRIPTION "Initial version of this MIB module."
::= { hpSwitch 10 }
-- Configuration support for Stacking
hpSwitchStackConfig OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 1 }
hpSwitchStackAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
candidate(1),
disabled(2),
member(3),
command(4),
pending(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The operational status of the stacking feature."
::= { hpSwitchStackConfig 1 }
hpSwitchStackCommandAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This variable is only valid if
'hpSwitchStackAdminStatus' has been set 'member'.
This is the MAC address of the command switch for
this member."
::= { hpSwitchStackConfig 2 }
hpSwitchStackName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This variable is only valid if
'hpSwitchStackAdminStatus' has been set
'command-switch'. This is the name of the stack for
which this switch is serving as the command switch
(maximum length of 20 characters)."
::= { hpSwitchStackConfig 3 }
hpSwitchStackPropagate OBJECT-TYPE
SYNTAX INTEGER{
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable SNMP community propagation. This
variable is only valid if 'hpSwitchStackAdminStatus'
has been set to 'command-switch'."
::= { hpSwitchStackConfig 4 }
hpSwitchStackAutoJoin OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable auto join on stack. This variable
is only valid for candidate switch."
::= { hpSwitchStackConfig 5 }
hpSwitchStackAutoGrab OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable auto grab on stack. This variable
is only valid if 'hpSwitchStackAdminStatus' has been
set to 'command-switch'."
::= { hpSwitchStackConfig 6 }
hpSwitchStackConfigMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpSwitchStackConfigMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains a group of member switches
configured to be in this switch's stack."
::= { hpSwitchVirtualStackMib 2 }
hpSwitchStackConfigMemberEntry OBJECT-TYPE
SYNTAX HpSwitchStackConfigMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A group of member switches configured to be in this
switch's stack."
INDEX { hpSwitchStackMemberSwitchNum }
::= { hpSwitchStackConfigMemberTable 1 }
HpSwitchStackConfigMemberEntry ::=
SEQUENCE {
hpSwitchStackMemberSwitchNum Integer32,
hpSwitchStackMemberMacAddr MacAddress,
hpSwitchStackMemberPassword OCTET STRING,
hpSwitchStackMemberEntryStatus RowStatus
}
hpSwitchStackMemberSwitchNum OBJECT-TYPE
SYNTAX Integer32 (1..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index that uniquely identifies the member switch
associated with this row entry."
::= { hpSwitchStackConfigMemberEntry 1 }
hpSwitchStackMemberMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The MAC Address that identifies the member switch."
::= { hpSwitchStackConfigMemberEntry 2 }
hpSwitchStackMemberPassword OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..17))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The manager password configured on the member switch.
This object always returns a 0 length octet string
when read."
::= { hpSwitchStackConfigMemberEntry 3 }
hpSwitchStackMemberEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of a stack member entry."
::= { hpSwitchStackConfigMemberEntry 4 }
-- Status support for Stacking
hpStackStats OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 3 }
hpStackStatsName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The stack name of this switch."
::= { hpStackStats 1 }
hpStackStatsMembersNum OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of members switches that have joined this
switch's stack. This variable is only valid if this
switch has been set as a 'command-switch'."
::= { hpStackStats 2 }
hpStackStatsMembersUnreachable OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of unreachable member switches. This
variable is only valid if this switch has been set as
a 'command-switch'."
::= { hpStackStats 3 }
hpStackStatsMemberID OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number by which member switch is known on the
stack."
::= { hpStackStats 4 }
hpStackStatsMgmtIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of the Stack manager switch (command
switch). This variable is only valid if this switch
has been set as a 'member-switch'."
::= { hpStackStats 5 }
hpStackStatsStackingStatus OBJECT-TYPE
SYNTAX INTEGER {
joined(1), -- joined successfully
pending(2), -- join pending
noReponse(3), -- No response from command switch
notCommand(4), -- Not a command switch
stackFull(5), -- Stack full on command switch
remoteFailure(6), -- Unknown remote failure
unknownFailure(7), -- Unknown failure
evicted(8), -- Evicted by command switch
commandUp(9), -- command switch is up
commandDown(10), -- command switch is down
unusedStatus(11), -- Status not currently used
undiscovered(12) -- Undiscovered switch
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of this switch. This variable is only
valid if this switch has been set as a 'member-switch'."
::= { hpStackStats 6 }
hpStackStatsMembersTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpStackStatsMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the member switches that have
joined this switch's stack."
::= { hpSwitchVirtualStackMib 4 }
hpStackStatsMemberEntry OBJECT-TYPE
SYNTAX HpStackStatsMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The information assosiated with each row in the
member table."
INDEX { hpStackStatsMemberSwitchIndx }
::= { hpStackStatsMembersTable 1 }
HpStackStatsMemberEntry ::=
SEQUENCE {
hpStackStatsMemberSwitchIndx Integer32,
hpStackStatsMemberMacAddr MacAddress,
hpStackStatsMemberSystemName OCTET STRING,
hpStackStatsMemberDeviceType OCTET STRING,
hpStackStatsMemberOperStatus INTEGER
}
hpStackStatsMemberSwitchIndx OBJECT-TYPE
SYNTAX Integer32 (0..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index identifying the member switch."
::= { hpStackStatsMemberEntry 1 }
hpStackStatsMemberMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the member switch."
::= { hpStackStatsMemberEntry 2 }
hpStackStatsMemberSystemName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The system name of the member switch."
::= { hpStackStatsMemberEntry 3 }
hpStackStatsMemberDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The device type of the member switch."
::= { hpStackStatsMemberEntry 4 }
hpStackStatsMemberOperStatus OBJECT-TYPE
SYNTAX INTEGER {
pending(1), -- join pending
joined(2), -- joined
noReponse(3), -- No response from
-- member switch
stackingDisabled(4), -- Stacking disabled
invalidPassword(5), -- Invalid password
commanderAnotherStack(6), -- Commander of another
-- stack
remoteFailure(7), -- Remote failure
unknownFailure(8), -- Unknown failure
rejected(9), -- rejected by command
-- switch
memberUp(10), -- member switch is up
memberDown(11), -- member switch is down
commanderThisStack(12), -- Commander of this stack
unusedStatus(13), -- Status not currently
-- being used
undiscovered(14) -- Undiscovered switch
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current state of the member switch."
::= { hpStackStatsMemberEntry 5 }
-- Configuration support for Discovery Protocol
hpSwitchDiscoveryConfig OBJECT IDENTIFIER ::=
{ hpSwitchVirtualStackMib 5 }
hpSwitchDiscoveryAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The operational status of the discovery protocol."
::= { hpSwitchDiscoveryConfig 1 }
hpSwitchDiscoveryTransmissionInterval OBJECT-TYPE
SYNTAX Integer32 (1..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The interval between the sending out of new
discovery packets."
::= { hpSwitchDiscoveryConfig 2 }
-- Status support for Discovery Protocol
hpDiscoverStatsCandidatesTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpDiscoverStatsCandidateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the switches that have been
discovered as a candidates to form a stack."
::= { hpSwitchVirtualStackMib 6 }
hpDiscoverStatsCandidateEntry OBJECT-TYPE
SYNTAX HpDiscoverStatsCandidateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The information assosiated with each row in the
candidate table."
INDEX { hpDiscoverStatsCandidateMacAddr }
::= { hpDiscoverStatsCandidatesTable 1 }
HpDiscoverStatsCandidateEntry ::=
SEQUENCE {
hpDiscoverStatsCandidateMacAddr MacAddress,
hpDiscoverStatsCandidateSystemName OCTET STRING,
hpDiscoverStatsCandidateDeviceType OCTET STRING
}
hpDiscoverStatsCandidateMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the candidate switch. Used as
an index identifying row in the table."
::= { hpDiscoverStatsCandidateEntry 1 }
hpDiscoverStatsCandidateSystemName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The system name of the candidate switch."
::= { hpDiscoverStatsCandidateEntry 2 }
hpDiscoverStatsCandidateDeviceType OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The device type of the candidate switch."
::= { hpDiscoverStatsCandidateEntry 3 }
hpDiscoverStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpDiscoverStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the switches that have been
discovered on the network."
::= { hpSwitchVirtualStackMib 7 }
hpDiscoverStatsEntry OBJECT-TYPE
SYNTAX HpDiscoverStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The information assosiated with each row in the
discover table."
INDEX { hpDiscoverStatsSwitchIndex }
::= { hpDiscoverStatsTable 1 }
HpDiscoverStatsEntry ::=
SEQUENCE {
hpDiscoverStatsSwitchIndex Integer32,
hpDiscoverStatsSwitchStackName OCTET STRING,
hpDiscoverStatsSwitchMacAddr MacAddress,
hpDiscoverStatsSwitchSystemName OCTET STRING,
hpDiscoverStatsSwitchStatus OCTET STRING
}
hpDiscoverStatsSwitchIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index identifying the row in the table."
::= { hpDiscoverStatsEntry 1 }
hpDiscoverStatsSwitchStackName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The stack name of the discovered switch."
::= { hpDiscoverStatsEntry 2 }
hpDiscoverStatsSwitchMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the discovered switch."
::= { hpDiscoverStatsEntry 3 }
hpDiscoverStatsSwitchSystemName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The system name of the discovered switch."
::= { hpDiscoverStatsEntry 4 }
hpDiscoverStatsSwitchStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..35))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of the discovered switch."
::= { hpDiscoverStatsEntry 5 }
hpSwitchVirtualStackMibConformance
OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 8 }
hpSwitchVirtualStackMibCompliances
OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMibConformance 1}
hpSwitchVirtualStackMibGroups
OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMibConformance 2}
hpSwitchVirtualStackMibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for devices implementing the
HP Stack Mib."
MODULE
MANDATORY-GROUPS { hpSwitchStackConfigGroup,
hpSwitchStackStatsGroup,
hpSwitchDiscoverConfigGroup,
hpDiscoverStatsGroup }
::= { hpSwitchVirtualStackMibCompliances 1 }
hpSwitchStackConfigGroup OBJECT-GROUP
OBJECTS { hpSwitchStackAdminStatus,
hpSwitchStackCommandAddr,
hpSwitchStackName,
hpSwitchStackPropagate,
hpSwitchStackAutoJoin,
hpSwitchStackAutoGrab,
hpSwitchStackMemberSwitchNum,
hpSwitchStackMemberMacAddr,
hpSwitchStackMemberPassword,
hpSwitchStackMemberEntryStatus
}
STATUS current
DESCRIPTION "A collection of objects for configuring a stack."
::= { hpSwitchVirtualStackMibGroups 1 }
hpSwitchStackStatsGroup OBJECT-GROUP
OBJECTS { hpStackStatsName,
hpStackStatsMembersNum,
hpStackStatsMembersUnreachable,
hpStackStatsMemberID,
hpStackStatsMgmtIpAddr,
hpStackStatsStackingStatus,
hpStackStatsMemberSwitchIndx,
hpStackStatsMemberMacAddr,
hpStackStatsMemberSystemName,
hpStackStatsMemberDeviceType,
hpStackStatsMemberOperStatus
}
STATUS current
DESCRIPTION "A collection of objects for determining state
and status of a stack."
::= { hpSwitchVirtualStackMibGroups 2 }
hpSwitchDiscoverConfigGroup OBJECT-GROUP
OBJECTS { hpSwitchDiscoveryAdminStatus,
hpSwitchDiscoveryTransmissionInterval
}
STATUS current
DESCRIPTION "A collection of objects for configuring the
state of the stack discovery protocol."
::= { hpSwitchVirtualStackMibGroups 3 }
hpDiscoverStatsGroup OBJECT-GROUP
OBJECTS { hpDiscoverStatsCandidateMacAddr,
hpDiscoverStatsCandidateSystemName,
hpDiscoverStatsCandidateDeviceType,
hpDiscoverStatsSwitchIndex,
hpDiscoverStatsSwitchStackName,
hpDiscoverStatsSwitchMacAddr,
hpDiscoverStatsSwitchSystemName,
hpDiscoverStatsSwitchStatus
}
STATUS current
DESCRIPTION "A collection of objects for viewing the
discovered devices by the stack discovery
protocol."
::= { hpSwitchVirtualStackMibGroups 4 }
END