mibs/MIBS/hp/NETSWITCH-MIB
2023-12-05 12:25:34 +01:00

488 lines
16 KiB
Plaintext

-- HP Enterprise Switch MIB
NETSWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
hpSwitch
FROM HP-ICF-OID;
-- Icf Switch Specific
hpOpSystem OBJECT IDENTIFIER ::= { hpSwitch 1 }
MacAddress ::= OCTET STRING (SIZE (6)) -- a 6 octet address
-- in the
-- "canonical"
-- order
-- HP Buffer group
-- The buffers group contains variables that describe the switch's use
-- of two types of global memory buffers: message buffers, which
-- facilitate internal process-to-process communication, and packet
-- buffers, which facilitate external communications by temporarily
-- storing incoming or outgoing data packets.
hpBuf OBJECT IDENTIFIER ::= { hpOpSystem 1 }
hpMsgBuf OBJECT IDENTIFIER ::= { hpBuf 1 }
hpPktBuf OBJECT IDENTIFIER ::= { hpBuf 2 }
hpMsgBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpMsgBufEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information on all the
Message buffers for each slot."
::= { hpMsgBuf 1 }
hpMsgBufEntry OBJECT-TYPE
SYNTAX HpMsgBufEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a slot in a chassis"
INDEX { hpMsgBufSlotIndex }
::= { hpMsgBufTable 1 }
HpMsgBufEntry ::=
SEQUENCE {
hpMsgBufSlotIndex INTEGER,
hpMsgBufInit INTEGER,
hpMsgBufFree INTEGER,
hpMsgBufMin INTEGER,
hpMsgBufMiss Counter,
hpMsgBufSize INTEGER,
hpMsgBufCorrupted Counter
}
hpMsgBufSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number within the box for which this
entry contains information."
::= { hpMsgBufEntry 1 }
hpMsgBufCorrupted OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a corrupted buffer was deleted."
::= { hpMsgBufEntry 2 }
hpMsgBufFree OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of message buffers available for
internal VME transfers or external transfers,
respectively. Because switch operations and application
software modules impose some overhead on global memory
buffers, the number of buffers available for data
transfers is less than the total number of buffers
allocated when the switch boots."
::= { hpMsgBufEntry 3 }
hpMsgBufInit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of message buffers allocated when
the switch booted."
::= { hpMsgBufEntry 4 }
hpMsgBufMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The smallest number of message buffers
available since the switch booted."
::= { hpMsgBufEntry 5 }
hpMsgBufMiss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times that the switch was unable to obtain
a message buffer. Failure to obtain a buffer indicates
that buffers were busy. This parameter is directly
related to hpMsgBufMin. If hpMsgBufMiss is greater than 0,
hpMsgBufMin must equal 0. Conversely, if hpMsgBufMiss
equals 0, then hpMsgBufMin must be greater than 0."
::= { hpMsgBufEntry 6 }
hpMsgBufSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the message buffer in bytes."
::= { hpMsgBufEntry 7 }
hpPktBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpPktBufEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information on all the
Packet buffers for each slot."
::= { hpPktBuf 1 }
hpPktBufEntry OBJECT-TYPE
SYNTAX HpPktBufEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a slot in a chassis"
INDEX { hpPktBufSlotIndex }
::= { hpPktBufTable 1 }
HpPktBufEntry ::=
SEQUENCE {
hpPktBufSlotIndex INTEGER,
hpPktBufInit INTEGER,
hpPktBufFree INTEGER,
hpPktBufMin INTEGER,
hpPktBufMiss Counter,
hpPktBufSize INTEGER,
hpPktBufCorrupted Counter
}
hpPktBufSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number within the box for which this
entry contains information."
::= { hpPktBufEntry 1 }
hpPktBufCorrupted OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a corrupted buffer was deleted."
::= { hpPktBufEntry 2 }
hpPktBufFree OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packet buffers available for
internal VME transfers or external transfers,
respectively. Because switch operations and application
software modules impose some overhead on global memory
buffers, the number of buffers available for data
transfers is less than the total number of buffers
allocated when the switch boots."
::= { hpPktBufEntry 3 }
hpPktBufInit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packet buffers allocated when
the switch booted."
::= { hpPktBufEntry 4 }
hpPktBufMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The smallest number of packet buffers
available since the switch booted."
::= { hpPktBufEntry 5 }
hpPktBufMiss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times that the switch was unable to obtain
a packet buffer. Failure to obtain a buffer indicates
that buffers were busy. This parameter is directly
related to hpPktBufMin. If hpPktBufMiss is greater than 0,
hpPktBufMin must equal 0. Conversely, if hpPktBufMiss
equals 0, then hpPktBufMin must be greater than 0."
::= { hpPktBufEntry 6 }
hpPktBufSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the packet buffer in bytes."
::= { hpPktBufEntry 7 }
-- HP Memory group
-- The memory group contains variables that describe the switch's use
-- of two types of memory : local memory and global memory. Depending
-- on the hardware platform these can have different meanings.
-- Typically local memory can be accessed by the network interface
-- chips and the main processor, while global memory can be accessed
-- by one or more main processors.
hpMem OBJECT IDENTIFIER ::= { hpOpSystem 2 }
hpLocalMem OBJECT IDENTIFIER ::= { hpMem 1 }
hpGlobalMem OBJECT IDENTIFIER ::= { hpMem 2 }
hpLocalMemTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpLocalMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information on all the
local memory for each slot."
::= { hpLocalMem 1 }
hpLocalMemEntry OBJECT-TYPE
SYNTAX HpLocalMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a slot in a chassis"
INDEX { hpLocalMemSlotIndex }
::= { hpLocalMemTable 1 }
HpLocalMemEntry ::=
SEQUENCE {
hpLocalMemSlotIndex INTEGER,
hpLocalMemSlabCnt Counter,
hpLocalMemFreeSegCnt Counter,
hpLocalMemAllocSegCnt Counter,
hpLocalMemTotalBytes INTEGER,
hpLocalMemFreeBytes INTEGER,
hpLocalMemAllocBytes INTEGER
}
hpLocalMemSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number within the box for which this
entry contains information."
::= { hpLocalMemEntry 1 }
hpLocalMemSlabCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of discretely managed memory areas.
Each slab is further broken down into smaller contiguous
areas called segments."
::= { hpLocalMemEntry 2 }
hpLocalMemFreeSegCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of free memory segments. A free memory
segment is an unused contiguous memory block of greater
than 16 bytes. Generally, an increase in the number of
free memory segments indicates an increase in memory
fragmentation."
::= { hpLocalMemEntry 3 }
hpLocalMemAllocSegCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently allocated memory segments."
::= { hpLocalMemEntry 4 }
hpLocalMemTotalBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently installed bytes."
::= { hpLocalMemEntry 5 }
hpLocalMemFreeBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of available (unallocated) bytes."
::= { hpLocalMemEntry 6 }
hpLocalMemAllocBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently allocated bytes."
::= { hpLocalMemEntry 7 }
hpGlobalMemTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpGlobalMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information on all the
local memory for each slot."
::= { hpGlobalMem 1 }
hpGlobalMemEntry OBJECT-TYPE
SYNTAX HpGlobalMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a slot in a chassis"
INDEX { hpGlobalMemSlotIndex }
::= { hpGlobalMemTable 1 }
HpGlobalMemEntry ::=
SEQUENCE {
hpGlobalMemSlotIndex INTEGER,
hpGlobalMemSlabCnt Counter,
hpGlobalMemFreeSegCnt Counter,
hpGlobalMemAllocSegCnt Counter,
hpGlobalMemTotalBytes INTEGER,
hpGlobalMemFreeBytes INTEGER,
hpGlobalMemAllocBytes INTEGER
}
hpGlobalMemSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number within the box for which this
entry contains information."
::= { hpGlobalMemEntry 1 }
hpGlobalMemSlabCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of discretely managed memory areas.
Each slab is further broken down into smaller contiguous
areas called segments."
::= { hpGlobalMemEntry 2 }
hpGlobalMemFreeSegCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of free memory segments. A free memory
segment is an unused contiguous memory block of greater
than 16 bytes. Generally, an increase in the number of
free memory segments indicates an increase in memory
fragmentation."
::= { hpGlobalMemEntry 3 }
hpGlobalMemAllocSegCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently allocated memory segments."
::= { hpGlobalMemEntry 4 }
hpGlobalMemTotalBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently installed bytes."
::= { hpGlobalMemEntry 5 }
hpGlobalMemFreeBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of available (unallocated) bytes."
::= { hpGlobalMemEntry 6 }
hpGlobalMemAllocBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently allocated bytes."
::= { hpGlobalMemEntry 7 }
hpSwitchOsVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the operating code version number (also
known as software or firmware). For example, a
software version such as A.08.01 is described as
follows:
A the function set available in your router
08 the common release number
01 updates to the current common release"
::= { hpOpSystem 3 }
hpSwitchRomVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the ROM version number (such as A.08.01
is described as follows:
A the function set available in your router
08 the common release number
01 updates to the current common release"
::= { hpOpSystem 4 }
hpSwitchSmartCardType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
fddi(2),
atm(3),
fddiAndATM(4),
other(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Return the type of Smart Cards in the system.
Some system may contains more than one types
of smart cards, such as FDDI and ATM"
::= { hpOpSystem 5 }
hpSwitchBaseMACAddress OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Return the base MAC address of the switch. This is
also the MAC address of the default vlan. "
::= { hpOpSystem 6 }
END