-- Copyright (C) 2015 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: HUAWEI DATASYNC MIB
|
|
-- Reference:
|
|
-- Version: V2.02
|
|
-- History:
|
|
-- <author>, <date>, <contents>
|
|
-- fengchong 2009-03-17
|
|
-- ==================================================================
|
|
|
|
-- ==================================================================
|
|
--
|
|
-- Variables and types are imported
|
|
--
|
|
-- ==================================================================
|
|
|
|
HUAWEI-DATASYNC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TimeTicks, Integer32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString, RowStatus, TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC;
|
|
|
|
hwDataSync MODULE-IDENTITY
|
|
LAST-UPDATED "201507161349Z"
|
|
ORGANIZATION
|
|
"Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"Modified hwCfgChgTerminalID."
|
|
REVISION "201507161349Z"
|
|
DESCRIPTION
|
|
"Add hwCfgLastSaveFailNotify ."
|
|
REVISION "201409041710Z"
|
|
DESCRIPTION
|
|
"The MIB module for Data sync between host and netmanager."
|
|
REVISION "200903171027Z"
|
|
DESCRIPTION
|
|
"The initial revision of this MIB module ."
|
|
::= { hwDatacomm 191 }
|
|
|
|
DateAndTime ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "2d-1d-1d,1d:1d:1d.1d,1a1d:1d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A date-time specification.
|
|
|
|
field octets contents range
|
|
----- ------ -------- -----
|
|
1 1-2 year* 0..65536
|
|
2 3 month 1..12
|
|
3 4 day 1..31
|
|
4 5 hour 0..23
|
|
5 6 minutes 0..59
|
|
6 7 seconds 0..60
|
|
(use 60 for leap-second)
|
|
7 8 deci-seconds 0..9
|
|
8 9 direction from UTC '+' / '-'
|
|
9 10 hours from UTC* 0..13
|
|
10 11 minutes from UTC 0..59
|
|
|
|
* Notes:
|
|
- the value of year is in network-byte order
|
|
- daylight saving time in New Zealand is +13
|
|
|
|
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be
|
|
displayed as:
|
|
|
|
1992-5-26,13:30:15.0,-4:0
|
|
Note that if only local time is known, then timezone
|
|
information (fields 8-10) is not present."
|
|
SYNTAX OCTET STRING (SIZE (8 | 11))
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- ==================================================================
|
|
--
|
|
-- ======================= definition begin =========================
|
|
--
|
|
-- ==================================================================
|
|
hwDataSyncScalarObjects OBJECT IDENTIFIER ::= { hwDataSync 1 }
|
|
hwDataSyncTableObjects OBJECT IDENTIFIER ::= { hwDataSync 2 }
|
|
hwDataSyncNotifications OBJECT IDENTIFIER ::= { hwDataSync 3 }
|
|
hwDataSyncConformance OBJECT IDENTIFIER ::= { hwDataSync 4 }
|
|
|
|
hwCurrentCfgChgSeqID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the ID of the current configuration change.
|
|
The value ranges from 0 to 65535. After the ID of the configuration change reaches
|
|
the maximum value, the value of the ID starts from 1 again.
|
|
After the device is restarted, the value of the ID becomes 0."
|
|
::= { hwDataSyncScalarObjects 1 }
|
|
|
|
hwCfgChgSeqIDReveralCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the cycle count of the index of configuration change table."
|
|
::= { hwDataSyncScalarObjects 2 }
|
|
|
|
hwCfgChgTableMaxItem OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the maximum number of entries in hwCfgChgTable. "
|
|
::= { hwDataSyncScalarObjects 3 }
|
|
|
|
|
|
hwCfgBaselineTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time of system confiuration was baseline."
|
|
::= { hwDataSyncScalarObjects 4 }
|
|
|
|
hwDataSyncGroups OBJECT IDENTIFIER ::= { hwDataSyncConformance 1 }
|
|
|
|
hwDataSyncScalarObjectsGroup OBJECT-GROUP
|
|
OBJECTS { hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount, hwCfgChgTableMaxItem, hwCfgBaselineTime}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects on DataSync ScalarObjects Information."
|
|
::= { hwDataSyncGroups 1 }
|
|
|
|
hwCfgChgNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { hwCfgChgNotify}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects on Configuration Change Information."
|
|
::= { hwDataSyncGroups 2 }
|
|
|
|
hwDataSyncNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { hwCfgLastSaveFailNotify }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects on synchronization Configuration Notify Information."
|
|
::= { hwDataSyncGroups 3 }
|
|
|
|
hwDataSyncCompliances OBJECT IDENTIFIER ::= { hwDataSyncConformance 2 }
|
|
|
|
hwDataSyncCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for
|
|
entities that support the huawei DataSync MIB."
|
|
MODULE -- this module
|
|
::= { hwDataSyncCompliances 1 }
|
|
|
|
hwCfgChgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwCfgChgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is used to record configuration changes.
|
|
In this table, you can find the configuration change based on the specific index."
|
|
::= { hwDataSyncTableObjects 1 }
|
|
|
|
|
|
hwCfgChgEntry OBJECT-TYPE
|
|
SYNTAX HwCfgChgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of hwCfgChgTable."
|
|
INDEX { hwCfgChgSeqID }
|
|
::= { hwCfgChgTable 1 }
|
|
|
|
|
|
HwCfgChgEntry::=
|
|
SEQUENCE {
|
|
hwCfgChgSeqID
|
|
Integer32,
|
|
hwCfgChgTime
|
|
DateAndTime,
|
|
hwCfgChgTerminalType
|
|
INTEGER,
|
|
hwCfgChgTerminalID
|
|
Integer32,
|
|
hwCfgChgType
|
|
INTEGER,
|
|
hwCfgChgViewName
|
|
OCTET STRING,
|
|
hwCfgChgCmdID
|
|
Integer32,
|
|
hwCfgChgDetailInfo
|
|
OCTET STRING
|
|
}
|
|
|
|
|
|
hwCfgChgSeqID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the configuration change ID.
|
|
When configuration is changed, the sequence id will plus 1."
|
|
::= { hwCfgChgEntry 1 }
|
|
|
|
hwCfgChgTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the configuration change time."
|
|
::= { hwCfgChgEntry 2 }
|
|
|
|
hwCfgChgTerminalType OBJECT-TYPE
|
|
SYNTAX INTEGER {snmp(1),telnet(2),netconf(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the type of the terminal."
|
|
::= { hwCfgChgEntry 3 }
|
|
|
|
hwCfgChgTerminalID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the terminal ID."
|
|
::= { hwCfgChgEntry 4 }
|
|
|
|
hwCfgChgType OBJECT-TYPE
|
|
SYNTAX INTEGER {create(1),modify(2),delete(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the configuration change type."
|
|
::= { hwCfgChgEntry 5 }
|
|
|
|
hwCfgChgViewName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the name of the view in which the configuration change occurs.
|
|
For the command operation, the object is the name of the view in which the command is run.
|
|
For the SNMP operation, the object is the OID of the MIB table or the scalar object."
|
|
::= { hwCfgChgEntry 6 }
|
|
|
|
|
|
hwCfgChgCmdID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the ID of the configuration change command.
|
|
For the SNMP operation, the value is 0."
|
|
::= { hwCfgChgEntry 7 }
|
|
|
|
hwCfgChgDetailInfo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates detailed configuration change information.
|
|
For the command operation, the object is the command line.
|
|
For the SNMP operation, the object is the index of the MIB table.
|
|
When there are multiple indexes, the format of index1.index2.index3 is adopted."
|
|
::= { hwCfgChgEntry 8 }
|
|
|
|
hwCollectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwCollectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is used to enable the NMS to send the collecting script to the device to trigger the collection,
|
|
and then monitor the collection status."
|
|
::= { hwDataSyncTableObjects 2 }
|
|
|
|
hwCollectEntry OBJECT-TYPE
|
|
SYNTAX HwCollectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of hwCollectTable."
|
|
INDEX { hwCollectIndex }
|
|
::= { hwCollectTable 1 }
|
|
|
|
HwCollectEntry ::=
|
|
SEQUENCE {
|
|
hwCollectIndex
|
|
Integer32,
|
|
hwCollectNetManageId
|
|
Integer32,
|
|
hwCollectOperation
|
|
INTEGER,
|
|
hwCollectInScriptFile
|
|
OCTET STRING,
|
|
hwCollectInResultFile
|
|
OCTET STRING,
|
|
hwCollectState
|
|
INTEGER,
|
|
hwCollectRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwCollectIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the collection index."
|
|
::= { hwCollectEntry 1 }
|
|
|
|
hwCollectNetManageId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object identifies the NMS ID."
|
|
::= { hwCollectEntry 2 }
|
|
|
|
hwCollectOperation OBJECT-TYPE
|
|
SYNTAX INTEGER {begin(1),stop(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the instruction for the collection operation.
|
|
Default value is stop."
|
|
::= { hwCollectEntry 3 }
|
|
|
|
hwCollectInScriptFile OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the name of the script file. T
|
|
he length of the file name ranges from 1 character to 255 characters."
|
|
::= { hwCollectEntry 4 }
|
|
|
|
hwCollectInResultFile OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the name of the result file.
|
|
The length of the file name ranges from 1 character to 255 characters."
|
|
::= { hwCollectEntry 5 }
|
|
|
|
|
|
hwCollectState OBJECT-TYPE
|
|
SYNTAX INTEGER {idle(1),collecting(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the collection status."
|
|
::= { hwCollectEntry 6 }
|
|
|
|
hwCollectRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the row status."
|
|
::= { hwCollectEntry 7 }
|
|
|
|
hwCfgChgNotify NOTIFICATION-TYPE
|
|
OBJECTS {hwCurrentCfgChgSeqID, hwCfgChgSeqIDReveralCount, hwCfgChgTableMaxItem, hwCfgBaselineTime}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is generated when a configuration change occurs
|
|
on the device within a specified period."
|
|
::= { hwDataSyncNotifications 1 }
|
|
|
|
hwCfgLastSaveFailNotify NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last save operation failed, please check the configuration."
|
|
::= { hwDataSyncNotifications 2 }
|
|
|
|
|
|
END
|
|
|
|
--
|
|