mibs/MIBS/huawei/HUAWEI-EPON-MIB
2023-12-05 12:25:34 +01:00

4275 lines
107 KiB
Plaintext

-- ==================================================================
-- Copyright (C) 2002 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 349
-- Reference:
-- Version: V1.0
-- History:
-- V1.0
-- ==================================================================
HUAWEI-EPON-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm, huaweiUtility
FROM HUAWEI-MIB
ifIndex
FROM IF-MIB
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
FROM SNMPv2-CONF
IpAddress, Integer32, Counter64, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
MacAddress, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC
EnabledStatus
FROM P-BRIDGE-MIB;
hwEponMIB MODULE-IDENTITY
LAST-UPDATED "200904240000Z"
ORGANIZATION
"Research & Development Dept, AN, Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Block 4, R&D Building,
Huawei Longgang Production Base,
Shenzhen, P.R.C.
http://www.huawei.com
Zip:518129"
DESCRIPTION
"Epon MIB, contain Epon."
::= { hwDatacomm 179 }
--
-- Type definitions
--
DisplayString ::= OCTET STRING
--
-- Textual conventions
--
PortList ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Each octet within this value specifies a set of eight
ports, with the first octet specifying ports 1 through
8, the second octet specifying ports 9 through 16 and others.
Within each octet, the most significant bit represents
the lowest numbered port, and the least significant bit
represents the highest numbered port. Thus, each port
of the bridge is represented by a single bit within the
value of this object. If that bit has a value of '1'
then that port is included in the set of ports; the port
is not included if its bit has a value of '0'."
SYNTAX OCTET STRING
--
-- Node definitions
--
hwEponObjects OBJECT IDENTIFIER ::= { hwEponMIB 1 }
hwEponGlobalObjects OBJECT IDENTIFIER ::= { hwEponObjects 1 }
hwEponAutoFindOnuAge OBJECT-TYPE
SYNTAX Integer32 (100..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The aging time of the auto-found ONU, ranging from 100(s) to 300(s)"
DEFVAL { 300 }
::= { hwEponGlobalObjects 1 }
hwEponCtcOuiId OBJECT-TYPE
SYNTAX Integer32(0..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OUI identifier"
DEFVAL { 111111 }
::= { hwEponGlobalObjects 2 }
hwEponChangePasswordAge OBJECT-TYPE
SYNTAX Integer32 (1..254)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval time of ONU's password renew, ranging from 1(s) to 254(s)"
DEFVAL { 10 }
::= { hwEponGlobalObjects 3 }
hwEponControlObjects OBJECT IDENTIFIER ::= { hwEponObjects 2 }
hwEponOltControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The control table of the EPON OLT."
::= { hwEponControlObjects 1 }
hwEponOltControlEntry OBJECT-TYPE
SYNTAX HwEponOltControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the control table of the EPON OLT."
INDEX { ifIndex }
::= { hwEponOltControlTable 1 }
HwEponOltControlEntry ::=
SEQUENCE {
hwEponOltControlfarthest
Integer32,
hwEponOltControlAutofindOnuEnable
EnabledStatus,
hwEponOltControlStatus
INTEGER,
hwEponOltControlUpStreamBandWidth
Counter64,
hwEponOltControlDownStreamBandWidth
Counter64
}
hwEponOltControlfarthest OBJECT-TYPE
SYNTAX Integer32(0..40)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the distance of the fiber between the OLT and the farthest ONU,
ranging from 0km to 40km."
DEFVAL { 20 }
::= { hwEponOltControlEntry 1 }
hwEponOltControlAutofindOnuEnable OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ONU auto-find is enabled."
::= { hwEponOltControlEntry 2 }
hwEponOltControlStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Epon port status in the OLT.
up (1): normal
down (2): fault"
::= { hwEponOltControlEntry 3 }
hwEponOltControlUpStreamBandWidth OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The up-stream bandwidth of the OLT port."
::= { hwEponOltControlEntry 4 }
hwEponOltControlDownStreamBandWidth OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The down-stream bandwidth of the OLT port."
::= { hwEponOltControlEntry 5 }
hwEponOnuConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to create, modify, delete or query an ONU."
::= { hwEponControlObjects 2 }
hwEponOnuConfigEntry OBJECT-TYPE
SYNTAX HwEponOnuConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU configuration entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuConfigTable 1 }
HwEponOnuConfigEntry ::=
SEQUENCE {
hwEponOnuIndex
Integer32,
hwEponOnuId
Integer32,
hwEponOnuAuthMode
INTEGER,
hwEponOnuMacAddress
MacAddress,
hwEponOnuPassword
DisplayString,
hwEponOnuTimeout
Integer32,
hwEponOnuManagementMode
INTEGER,
hwEponOnuLineProfName
DisplayString,
hwEponOnuServiceProfName
DisplayString,
hwEponOnuSnmpProfName
DisplayString,
hwEponOnuDescription
DisplayString,
hwEponOnuActiveStatus
INTEGER,
hwEponOnuRowStatus
RowStatus
}
hwEponOnuIndex OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the index."
::= { hwEponOnuConfigEntry 1 }
hwEponOnuId OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ONU ID."
::= { hwEponOnuConfigEntry 2 }
hwEponOnuAuthMode OBJECT-TYPE
SYNTAX INTEGER
{
sn(1),
alwaysOn(3),
onceOn(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The authentication mode for the ONU."
::= { hwEponOnuConfigEntry 3 }
hwEponOnuMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the MAC address of the ONU."
::= { hwEponOnuConfigEntry 4 }
hwEponOnuPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the password of the ONU ."
::= { hwEponOnuConfigEntry 5 }
hwEponOnuTimeout OBJECT-TYPE
SYNTAX Integer32 (1..168)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The online duration of the ONU, ranging from 1 to 168 hours."
::= { hwEponOnuConfigEntry 6 }
hwEponOnuManagementMode OBJECT-TYPE
SYNTAX INTEGER
{
oam(1),
snmp(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ONU managemet mode, including OAM mode and SNMP mode."
DEFVAL { 1 }
::= { hwEponOnuConfigEntry 7 }
hwEponOnuLineProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The line profile name, which is bound to ONU."
::= { hwEponOnuConfigEntry 8 }
hwEponOnuServiceProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The service profile name, which is bound to ONU."
::= { hwEponOnuConfigEntry 9 }
hwEponOnuSnmpProfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SNMP profile name, which is bound to ONU."
::= { hwEponOnuConfigEntry 10 }
hwEponOnuDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The description of the ONU."
::= { hwEponOnuConfigEntry 11 }
hwEponOnuActiveStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
deactive(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to activate or deactivate an ONU. "
DEFVAL { 1 }
::= { hwEponOnuConfigEntry 12 }
hwEponOnuRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row."
::= { hwEponOnuConfigEntry 51 }
hwEponOnuVersionTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuVersionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the ONU version information table."
::= { hwEponControlObjects 3 }
hwEponOnuVersionEntry OBJECT-TYPE
SYNTAX HwEponOnuVersionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU version information entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuVersionTable 1 }
HwEponOnuVersionEntry ::=
SEQUENCE {
hwEponOnuVendorId
DisplayString,
hwEponOnuModel
Integer32,
hwEponOnuOnuIdentifier
DisplayString,
hwEponOnuHardwareVersion
DisplayString,
hwEponOnuSoftwareVersion
DisplayString,
hwEponOnuChipVenderId
DisplayString,
hwEponOnuChipModel
Integer32,
hwEponOnuChipVersion
Integer32,
hwEponOnuChipDesignDate
DisplayString,
hwEponOnuFirmwareVersion
Integer32
}
hwEponOnuVendorId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the ONU vendor ID."
::= { hwEponOnuVersionEntry 1 }
hwEponOnuModel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ONU model."
::= { hwEponOnuVersionEntry 2 }
hwEponOnuOnuIdentifier OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ONU identifier."
::= { hwEponOnuVersionEntry 3 }
hwEponOnuHardwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The hardware version of the ONU."
::= { hwEponOnuVersionEntry 4 }
hwEponOnuSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version of the ONU."
::= { hwEponOnuVersionEntry 5 }
hwEponOnuChipVenderId OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The verder ID of the ONU's chip."
::= { hwEponOnuVersionEntry 6 }
hwEponOnuChipModel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The model of the ONU's chip."
::= { hwEponOnuVersionEntry 7 }
hwEponOnuChipVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The verion of the ONU's chip."
::= { hwEponOnuVersionEntry 8 }
hwEponOnuChipDesignDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The production date of the ONU's chip."
::= { hwEponOnuVersionEntry 9 }
hwEponOnuFirmwareVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware version of the ONU's chip."
::= { hwEponOnuVersionEntry 10 }
hwEponOnuControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the control table of the ONU. The indexes are IF index and ONU ID."
::= { hwEponControlObjects 4 }
hwEponOnuControlEntry OBJECT-TYPE
SYNTAX HwEponOnuControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU control entry, including a set of operations performed on the ONU."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuControlTable 1 }
HwEponOnuControlEntry ::=
SEQUENCE {
hwEponOnuReset
Integer32,
hwEponOnuReRegister
Integer32,
hwEponOnuReDiscovery
Integer32,
hwEponOnuRunStatus
INTEGER,
hwEponOnuDistance
Integer32,
hwEponOnuRtt
Integer32,
hwEponOnuLastUpTime
DisplayString,
hwEponOnuLastDownTime
DisplayString,
hwEponOnuLastDownCause
Integer32
}
hwEponOnuReset OBJECT-TYPE
SYNTAX Integer32 (1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset an ONU."
DEFVAL { 1 }
::= { hwEponOnuControlEntry 1 }
hwEponOnuReRegister OBJECT-TYPE
SYNTAX Integer32 (1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to re-register an ONU."
DEFVAL { 1 }
::= { hwEponOnuControlEntry 2 }
hwEponOnuReDiscovery OBJECT-TYPE
SYNTAX Integer32 (1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to reset the discovery status of an ONU.
If the authentication mode is once-on(4),
after performing the rediscovery operation,
the online duration is re-timed."
DEFVAL { 1 }
::= { hwEponOnuControlEntry 3 }
hwEponOnuRunStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The running status of the ONU: up means normal and down means faulty."
::= { hwEponOnuControlEntry 4 }
hwEponOnuDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance of the ONU (km)."
::= { hwEponOnuControlEntry 5 }
hwEponOnuRtt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RTT of the ONU (TQ)."
::= { hwEponOnuControlEntry 6 }
hwEponOnuLastUpTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last online time of the ONU, including the year (2 bytes),
month (1 byte), date (1 byte), hour (1 byte), minute (1 byte),
second (1 byte) and week (1 byte)."
::= { hwEponOnuControlEntry 7 }
hwEponOnuLastDownTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Last offline time of the ONU, including the year (2 bytes),
month (1 byte), date (1 byte), hour (1 byte), minute (1 byte),
second (1 byte), and the week (1 byte)."
::= { hwEponOnuControlEntry 8 }
hwEponOnuLastDownCause OBJECT-TYPE
SYNTAX Integer32 (1 | 7..10 | 13)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last offline reason."
::= { hwEponOnuControlEntry 9 }
hwEponAutoFindOnuInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponAutoFindOnuInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the auto find table of the ONU."
::= { hwEponControlObjects 5 }
hwEponAutoFindOnuInfoEntry OBJECT-TYPE
SYNTAX HwEponAutoFindOnuInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU auto-find entry, including a set of operations of the ONU auto-find."
INDEX { ifIndex, hwEponAutoFindOnuOrder }
::= { hwEponAutoFindOnuInfoTable 1 }
HwEponAutoFindOnuInfoEntry ::=
SEQUENCE {
hwEponAutoFindOnuOrder
Integer32,
hwEponAutoFindOnuInfoMacAddress
MacAddress,
hwEponAutoFindOnuInfoPasswordValue
DisplayString
}
hwEponAutoFindOnuOrder OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SN of the auto-found ONU."
::= { hwEponAutoFindOnuInfoEntry 1 }
hwEponAutoFindOnuInfoMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the auto-found ONU."
::= { hwEponAutoFindOnuInfoEntry 2 }
hwEponAutoFindOnuInfoPasswordValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The password of the auto-found ONU."
::= { hwEponAutoFindOnuInfoEntry 3 }
hwEponOnuCapabilityInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuCapabilityInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The capability table of the ONU."
::= { hwEponControlObjects 6 }
hwEponOnuCapabilityInfoEntry OBJECT-TYPE
SYNTAX HwEponOnuCapabilityInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the entry of the ONU capbility."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuCapabilityInfoTable 1 }
HwEponOnuCapabilityInfoEntry ::=
SEQUENCE {
hwEponOnuPotsPortNum
Integer32,
hwEponOnuFePortsNum
Integer32,
hwEponOnuGePortsNum
Integer32,
hwEponOnuTdmPortsNum
Integer32,
hwEponOnuFecSupport
Integer32,
hwEponOnuSupportBackupBattery
Integer32,
hwEponOnuUpQueueNum
Integer32,
hwEponOnuUpQueueNumPerPort
Integer32,
hwEponOnuDownQueueNum
Integer32,
hwEponOnuDownQueueNumPerPort
Integer32,
hwEponOnuFePortList
PortList,
hwEponOnuGePortList
PortList,
hwEponOnuSupportMulticastQuickLeave
Integer32
}
hwEponOnuPotsPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of POTS ports of the ONU."
::= { hwEponOnuCapabilityInfoEntry 1 }
hwEponOnuFePortsNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of FE ports of the ONU."
::= { hwEponOnuCapabilityInfoEntry 2 }
hwEponOnuGePortsNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of GE ports of the ONU."
::= { hwEponOnuCapabilityInfoEntry 3 }
hwEponOnuTdmPortsNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of TDM ports of the ONU."
::= { hwEponOnuCapabilityInfoEntry 4 }
hwEponOnuFecSupport OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Does the ONU support FEC."
::= { hwEponOnuCapabilityInfoEntry 5 }
hwEponOnuSupportBackupBattery OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Does the ONU support backup batter."
::= { hwEponOnuCapabilityInfoEntry 6 }
hwEponOnuUpQueueNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of upstream queues of the ONU."
::= { hwEponOnuCapabilityInfoEntry 7 }
hwEponOnuUpQueueNumPerPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of queues on the upstream port of the ONU."
::= { hwEponOnuCapabilityInfoEntry 8 }
hwEponOnuDownQueueNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of downstram queues of the ONU."
::= { hwEponOnuCapabilityInfoEntry 9 }
hwEponOnuDownQueueNumPerPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of queues on the downstream port of the ONU."
::= { hwEponOnuCapabilityInfoEntry 10 }
hwEponOnuFePortList OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bit-map of FE port."
::= { hwEponOnuCapabilityInfoEntry 11 }
hwEponOnuGePortList OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The bit-map of GE port."
::= { hwEponOnuCapabilityInfoEntry 12 }
hwEponOnuSupportMulticastQuickLeave OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Does the ONU support multicast quick-leave."
::= { hwEponOnuCapabilityInfoEntry 13 }
hwEponOnuIpConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuIpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the ONU IP configuration table.
This table is used to configure and query
the IP configuration mode and IP address of an ONU."
::= { hwEponControlObjects 7 }
hwEponOnuIpConfigEntry OBJECT-TYPE
SYNTAX HwEponOnuIpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU IP config entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuIpConfigTable 1 }
HwEponOnuIpConfigEntry ::=
SEQUENCE {
hwEponOnuIpAddress
IpAddress,
hwEponOnuNetMask
IpAddress,
hwEponOnuNetGateway
IpAddress,
hwEponOnuIpManageVlan
Integer32,
hwEponOnuIpRowStates
RowStatus
}
hwEponOnuIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP address."
::= { hwEponOnuIpConfigEntry 1 }
hwEponOnuNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sub-net mask."
::= { hwEponOnuIpConfigEntry 2 }
hwEponOnuNetGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ONU NMS gateway."
::= { hwEponOnuIpConfigEntry 3 }
hwEponOnuIpManageVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The management VLAN of the ONU."
::= { hwEponOnuIpConfigEntry 4 }
hwEponOnuIpRowStates OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row."
::= { hwEponOnuIpConfigEntry 51 }
hwEponOnuEthObjectCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuEthObjectCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU ETH port config table."
::= { hwEponControlObjects 8 }
hwEponOnuEthObjectCfgEntry OBJECT-TYPE
SYNTAX HwEponOnuEthObjectCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU ETH port config entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuEthPortId }
::= { hwEponOnuEthObjectCfgTable 1 }
HwEponOnuEthObjectCfgEntry ::=
SEQUENCE {
hwEponOnuEthPortId
Integer32,
hwEponOnuEthOperateStatus
INTEGER,
hwEponOnuEthFlowcontrolSwitch
INTEGER
}
hwEponOnuEthPortId OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ETH port number of the ONU."
::= { hwEponOnuEthObjectCfgEntry 1 }
hwEponOnuEthOperateStatus OBJECT-TYPE
SYNTAX INTEGER
{
undoshutdown(1),
shutdown(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The operation status of the port."
DEFVAL { 1 }
::= { hwEponOnuEthObjectCfgEntry 2 }
hwEponOnuEthFlowcontrolSwitch OBJECT-TYPE
SYNTAX INTEGER
{
open(1),
close(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling or disabling flow control on the ONU port."
::= { hwEponOnuEthObjectCfgEntry 3 }
hwEponOnuTdmPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuTdmPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU TDM port config table."
::= { hwEponControlObjects 9 }
hwEponOnuTdmPortCfgEntry OBJECT-TYPE
SYNTAX HwEponOnuTdmPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU TDM port config entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuTdmPortId }
::= { hwEponOnuTdmPortCfgTable 1 }
HwEponOnuTdmPortCfgEntry ::=
SEQUENCE {
hwEponOnuTdmPortId
Integer32,
hwEponOnuTdmPortOperateStatus
INTEGER
}
hwEponOnuTdmPortId OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU TDM port ID."
::= { hwEponOnuTdmPortCfgEntry 1 }
hwEponOnuTdmPortOperateStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The enable switch of the port."
::= { hwEponOnuTdmPortCfgEntry 2 }
hwEponOnuPotsPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuPotsPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU POTS port config table."
::= { hwEponControlObjects 10 }
hwEponOnuPotsPortCfgEntry OBJECT-TYPE
SYNTAX HwEponOnuPotsPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU POTS port config entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuPotsPortId }
::= { hwEponOnuPotsPortCfgTable 1 }
HwEponOnuPotsPortCfgEntry ::=
SEQUENCE {
hwEponOnuPotsPortId
Integer32,
hwEponOnuPotsPortOperateStatus
INTEGER
}
hwEponOnuPotsPortId OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU POTS port number."
::= { hwEponOnuPotsPortCfgEntry 1 }
hwEponOnuPotsPortOperateStatus OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operation status of the ONU POTS port."
::= { hwEponOnuPotsPortCfgEntry 2 }
hwEponOnuCfgCarTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuCfgCarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU CAR config table."
::= { hwEponControlObjects 11 }
hwEponOnuCfgCarEntry OBJECT-TYPE
SYNTAX HwEponOnuCfgCarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU CAR config entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuCfgCarDirection }
::= { hwEponOnuCfgCarTable 1 }
HwEponOnuCfgCarEntry ::=
SEQUENCE {
hwEponOnuCfgCarDirection
INTEGER,
hwEponOnuCarProfileNameIndex
DisplayString,
hwEponOnuTrafficPolicyNameIndex
DisplayString,
hwEponOnuCfgCarRowStatus
RowStatus
}
hwEponOnuCfgCarDirection OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The direction of packets where CAR is performed."
::= { hwEponOnuCfgCarEntry 1 }
hwEponOnuCarProfileNameIndex OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"CAR profile name."
::= { hwEponOnuCfgCarEntry 2 }
hwEponOnuTrafficPolicyNameIndex OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Traffic policy name."
::= { hwEponOnuCfgCarEntry 3 }
hwEponOnuCfgCarRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row."
::= { hwEponOnuCfgCarEntry 51 }
hwEponOltPortDefaultVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltPortDefaultVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT default VLAN config table."
::= { hwEponControlObjects 12 }
hwEponOltPortDefaultVlanEntry OBJECT-TYPE
SYNTAX HwEponOltPortDefaultVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT default VLAN config entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOltPortDefaultVlanTable 1 }
HwEponOltPortDefaultVlanEntry ::=
SEQUENCE {
hwEponOltPortDefaultVlanId
Integer32,
hwEponOltPortDefaultVlanBatch
INTEGER,
hwEponOltPortDefaultVlanOnuStartId
Integer32,
hwEponOltPortDefaultVlanOnuEndId
Integer32,
hwEponOltPortDefaultVlanRowStatus
RowStatus
}
hwEponOltPortDefaultVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN ID on the port."
::= { hwEponOltPortDefaultVlanEntry 1 }
hwEponOltPortDefaultVlanBatch OBJECT-TYPE
SYNTAX INTEGER
{
batch(1),
notBatch(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Batch config."
::= { hwEponOltPortDefaultVlanEntry 2 }
hwEponOltPortDefaultVlanOnuStartId OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Start ONU ID in batch configuration."
::= { hwEponOltPortDefaultVlanEntry 3 }
hwEponOltPortDefaultVlanOnuEndId OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"End ONU ID in batch configuration."
::= { hwEponOltPortDefaultVlanEntry 4 }
hwEponOltPortDefaultVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row."
::= { hwEponOltPortDefaultVlanEntry 51 }
hwEponVlanStackingAndMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponVlanStackingAndMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU stacking and mapping config table."
::= { hwEponControlObjects 13 }
hwEponVlanStackingAndMappingEntry OBJECT-TYPE
SYNTAX HwEponVlanStackingAndMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU stacking and mapping config entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuExtSVlanId, hwEponOnuIntSStartVlanId, hwEponOnuIntSEndVlanId}
::= { hwEponVlanStackingAndMappingTable 1 }
HwEponVlanStackingAndMappingEntry ::=
SEQUENCE {
hwEponOnuExtSVlanId
Integer32,
hwEponOnuIntSStartVlanId
Integer32,
hwEponOnuIntSEndVlanId
Integer32,
hwEponVlanStackingOrMapping
INTEGER,
hwEponOnuDextVlanId
Integer32,
hwEponOnuDintVlanId
Integer32,
hwEponOnuPopExtVlanId
INTEGER,
hwEponOnuVlanCopyPri
INTEGER,
hwEponOnuIntVlanRemarkPri
INTEGER,
hwEponOnuExtVlanRemarkPri
INTEGER,
hwEponOnuIntVlanPri
Integer32,
hwEponOnuExtVlanPri
Integer32,
hwEponVlanMappingBatch
INTEGER,
hwEponVlanMappingOnuStartId
Integer32,
hwEponVlanMappingOnuEndId
Integer32,
hwEponVlanMappingRowStatus
RowStatus
}
hwEponOnuExtSVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Source VLAN ID."
::= { hwEponVlanStackingAndMappingEntry 1 }
hwEponOnuIntSStartVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Source inner start VLAN ID."
::= { hwEponVlanStackingAndMappingEntry 2 }
hwEponOnuIntSEndVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Source inner end VLAN ID."
::= { hwEponVlanStackingAndMappingEntry 3 }
hwEponVlanStackingOrMapping OBJECT-TYPE
SYNTAX INTEGER
{
singleMapping(1),
doubleMapping(2),
stacking(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Stacking or mapping."
::= { hwEponVlanStackingAndMappingEntry 4 }
hwEponOnuDextVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Mapping the outer VLAN ID of destination."
::= { hwEponVlanStackingAndMappingEntry 5 }
hwEponOnuDintVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Mapping the inner VLAN ID of destination."
::= { hwEponVlanStackingAndMappingEntry 6 }
hwEponOnuPopExtVlanId OBJECT-TYPE
SYNTAX INTEGER
{
pop(1),
notPop(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Whether to remove the outer VLAN ID."
::= { hwEponVlanStackingAndMappingEntry 7 }
hwEponOnuVlanCopyPri OBJECT-TYPE
SYNTAX INTEGER
{
copy(1),
notCopy(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Copy VLAN COS value."
::= { hwEponVlanStackingAndMappingEntry 8 }
hwEponOnuIntVlanRemarkPri OBJECT-TYPE
SYNTAX INTEGER
{
remark(1),
notRemark(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Remark inner VLAN COS value."
::= { hwEponVlanStackingAndMappingEntry 9 }
hwEponOnuExtVlanRemarkPri OBJECT-TYPE
SYNTAX INTEGER
{
remark(1),
notRemark(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Remark outer VLAN COS value."
::= { hwEponVlanStackingAndMappingEntry 10 }
hwEponOnuIntVlanPri OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The inner VLAN COS vlaue."
::= { hwEponVlanStackingAndMappingEntry 11 }
hwEponOnuExtVlanPri OBJECT-TYPE
SYNTAX Integer32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The outer VLAN COS vlaue."
::= { hwEponVlanStackingAndMappingEntry 12 }
hwEponVlanMappingBatch OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Batch config."
::= { hwEponVlanStackingAndMappingEntry 13 }
hwEponVlanMappingOnuStartId OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Start ONU ID."
::= { hwEponVlanStackingAndMappingEntry 14 }
hwEponVlanMappingOnuEndId OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"End ONU ID."
::= { hwEponVlanStackingAndMappingEntry 15 }
hwEponVlanMappingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row. "
::= { hwEponVlanStackingAndMappingEntry 51 }
hwEponOltPortStaticMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltPortStaticMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT static MAC address table."
::= { hwEponControlObjects 14 }
hwEponOltPortStaticMacEntry OBJECT-TYPE
SYNTAX HwEponOltPortStaticMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT static MAC address entry"
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuUserMacAddressOrder }
::= { hwEponOltPortStaticMacTable 1 }
HwEponOltPortStaticMacEntry ::=
SEQUENCE {
hwEponOnuUserMacAddressOrder
Integer32,
hwEponOnuUserMacAddress
MacAddress,
hwEponOltPortStaticMacRowStatus
RowStatus
}
hwEponOnuUserMacAddressOrder OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of the static MAC address."
::= { hwEponOltPortStaticMacEntry 1 }
hwEponOnuUserMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MAC address."
::= { hwEponOltPortStaticMacEntry 2 }
hwEponOltPortStaticMacRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row. "
::= { hwEponOltPortStaticMacEntry 51 }
hwEponOltPortMacLimitTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltPortMacLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MAC address learning limit table."
::= { hwEponControlObjects 15 }
hwEponOltPortMacLimitEntry OBJECT-TYPE
SYNTAX HwEponOltPortMacLimitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MAC address learning limit entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOltPortMacLimitTable 1 }
HwEponOltPortMacLimitEntry ::=
SEQUENCE {
hwEponOnuUserMacAddressNumber
Integer32,
hwEponOnuForwardAction
INTEGER,
hwEponOnuAlarmAction
INTEGER,
hwEponOnuMacLimitRowStatus
RowStatus
}
hwEponOnuUserMacAddressNumber OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum number of MAC addresses that can be learned."
DEFVAL { 4094 }
::= { hwEponOltPortMacLimitEntry 1 }
hwEponOnuForwardAction OBJECT-TYPE
SYNTAX INTEGER
{
forward(1),
discard(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Forwarding action."
DEFVAL { 2 }
::= { hwEponOltPortMacLimitEntry 2 }
hwEponOnuAlarmAction OBJECT-TYPE
SYNTAX INTEGER
{
warning(1),
notWarning(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Alarm action."
DEFVAL { 1 }
::= { hwEponOltPortMacLimitEntry 3 }
hwEponOnuMacLimitRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status, which is used to differentiate the creation, modification and deletion of a row. "
::= { hwEponOltPortMacLimitEntry 51 }
hwEponProfileObjects OBJECT IDENTIFIER ::= { hwEponObjects 3 }
hwEponLineProfileInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponLineProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the EPON line profile table. This table is
used to create a EPON line profile."
::= { hwEponProfileObjects 1 }
hwEponLineProfileInfoEntry OBJECT-TYPE
SYNTAX HwEponLineProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The EPON line profile entry."
INDEX { hwEponLineProfileNameIndex }
::= { hwEponLineProfileInfoTable 1 }
HwEponLineProfileInfoEntry ::=
SEQUENCE {
hwEponLineProfileNameIndex
DisplayString,
hwEponLineProfileBindNum
Integer32,
hwEponLineProfileDbaProfileName
DisplayString,
hwEponLineProfileEncryptMode
INTEGER,
hwEponLineProfileQueueSetIndex1Threshold
DisplayString,
hwEponLineProfileQueueSetIndex2Threshold
DisplayString,
hwEponLineProfileQueueSetIndex3Threshold
DisplayString,
hwEponLineProfileRowStatus
RowStatus
}
hwEponLineProfileNameIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the EPON line profile."
::= { hwEponLineProfileInfoEntry 1 }
hwEponLineProfileBindNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of EPON line profiles bound to the ONU."
::= { hwEponLineProfileInfoEntry 2 }
hwEponLineProfileDbaProfileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the EPON line DBA profile."
::= { hwEponLineProfileInfoEntry 3 }
hwEponLineProfileEncryptMode OBJECT-TYPE
SYNTAX INTEGER
{
aes(1),
tripleChurining(2),
off(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Encryption mode of the EPON line profile."
::= { hwEponLineProfileInfoEntry 4 }
hwEponLineProfileQueueSetIndex1Threshold OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..500))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold of queue set 1 in the EPON line profile."
::= { hwEponLineProfileInfoEntry 5 }
hwEponLineProfileQueueSetIndex2Threshold OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..500))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold of queue set 2 in the EPON line profile."
::= { hwEponLineProfileInfoEntry 6 }
hwEponLineProfileQueueSetIndex3Threshold OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..500))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold of queue set 3 in the EPON line profile."
::= { hwEponLineProfileInfoEntry 7 }
hwEponLineProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponLineProfileInfoEntry 51 }
hwEponOnuSrvProfileInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuSrvProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the EPON service profile table."
::= { hwEponProfileObjects 2 }
hwEponOnuSrvProfileInfoEntry OBJECT-TYPE
SYNTAX HwEponOnuSrvProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The EPON service profile entry."
INDEX { hwEponOnuSrvProfNameIndex }
::= { hwEponOnuSrvProfileInfoTable 1 }
HwEponOnuSrvProfileInfoEntry ::=
SEQUENCE {
hwEponOnuSrvProfNameIndex
DisplayString,
hwEponOnuSrvProfileBindNum
Integer32,
hwEponOnuSrvProfileRowStatus
RowStatus
}
hwEponOnuSrvProfNameIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the EPON service profile."
::= { hwEponOnuSrvProfileInfoEntry 1 }
hwEponOnuSrvProfileBindNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of EPON service profiles bound to the ONU."
::= { hwEponOnuSrvProfileInfoEntry 2 }
hwEponOnuSrvProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponOnuSrvProfileInfoEntry 51 }
hwEponSrvProfileOnuCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfileOnuCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the EPON service profile ONU config table."
::= { hwEponProfileObjects 3 }
hwEponSrvProfileOnuCfgEntry OBJECT-TYPE
SYNTAX HwEponSrvProfileOnuCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The EPON service profile ONU config entry."
INDEX { hwEponOnuSrvProfNameIndex }
::= { hwEponSrvProfileOnuCfgTable 1 }
HwEponSrvProfileOnuCfgEntry ::=
SEQUENCE {
hwEponSrvProfileFecMode
EnabledStatus,
hwEponSrvProfileMulticastMode
INTEGER,
hwEponSrvProfileMulticastQuickLeaveSwitch
EnabledStatus
}
hwEponSrvProfileFecMode OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FEC mode of the EPON service profile."
::= { hwEponSrvProfileOnuCfgEntry 4 }
hwEponSrvProfileMulticastMode OBJECT-TYPE
SYNTAX INTEGER
{
ctc(1),
igmpsnooping(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Multicast mode of the EPON service profile."
::= { hwEponSrvProfileOnuCfgEntry 5 }
hwEponSrvProfileMulticastQuickLeaveSwitch OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enabling or disabling multicast quickleave of the EPON service profile."
::= { hwEponSrvProfileOnuCfgEntry 6 }
hwEponSrvProfOnuPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfOnuPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the EPON service profile ONU port config table."
::= { hwEponProfileObjects 4 }
hwEponSrvProfOnuPortCfgEntry OBJECT-TYPE
SYNTAX HwEponSrvProfOnuPortCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The EPON service profile ONU port config entry."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuPortTypeIndex, hwEponOnuPortIdIndex }
::= { hwEponSrvProfOnuPortCfgTable 1 }
HwEponSrvProfOnuPortCfgEntry ::=
SEQUENCE {
hwEponOnuPortTypeIndex
INTEGER,
hwEponOnuPortIdIndex
Integer32,
hwEponSrvProfOnuPortCfgMaxMacAddressNum
Integer32,
hwEponSrvProfOnuPortCfgMulticastStripSwitch
INTEGER
}
hwEponOnuPortTypeIndex OBJECT-TYPE
SYNTAX INTEGER
{
eth1(1),
eth2(2),
eth3(3),
eth4(48)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port type of the ONU."
::= { hwEponSrvProfOnuPortCfgEntry 1 }
hwEponOnuPortIdIndex OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port index of the ONU."
::= { hwEponSrvProfOnuPortCfgEntry 2 }
hwEponSrvProfOnuPortCfgMaxMacAddressNum OBJECT-TYPE
SYNTAX Integer32 (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max number of MAC addresses that can be learned on an ONU port."
::= { hwEponSrvProfOnuPortCfgEntry 3 }
hwEponSrvProfOnuPortCfgMulticastStripSwitch OBJECT-TYPE
SYNTAX INTEGER
{
strip(1),
notStrip(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Whether to remove VLAN tags from multicast packets on an ONU port."
::= { hwEponSrvProfOnuPortCfgEntry 4 }
hwEponSrvProfMulticastVlanCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfMulticastVlanCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the EPON service profile multicast VLAN config table."
::= { hwEponProfileObjects 5 }
hwEponSrvProfMulticastVlanCfgEntry OBJECT-TYPE
SYNTAX HwEponSrvProfMulticastVlanCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The EPON service profile multi-cast VLAN config entry."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuPortTypeIndex, hwEponOnuPortIdIndex, hwEponSrvProfMulticastVlanCfgMulticastVlan }
::= { hwEponSrvProfMulticastVlanCfgTable 1 }
HwEponSrvProfMulticastVlanCfgEntry ::=
SEQUENCE {
hwEponSrvProfMulticastVlanCfgMulticastVlan
Integer32,
hwEponSrvProfMulticastVlanCfgRowStatus
RowStatus
}
hwEponSrvProfMulticastVlanCfgMulticastVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Multicast VLAN ID in the EPON service profile."
::= { hwEponSrvProfMulticastVlanCfgEntry 1 }
hwEponSrvProfMulticastVlanCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponSrvProfMulticastVlanCfgEntry 51 }
hwEponSrvProfOnuPortVlanCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfOnuPortVlanCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port's remote native VLAN info table."
::= { hwEponProfileObjects 6 }
hwEponSrvProfOnuPortVlanCfgEntry OBJECT-TYPE
SYNTAX HwEponSrvProfOnuPortVlanCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port's remote native VLAN info entry."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuPortType, hwEponOnuPortId }
::= { hwEponSrvProfOnuPortVlanCfgTable 1 }
HwEponSrvProfOnuPortVlanCfgEntry ::=
SEQUENCE {
hwEponOnuPortType
INTEGER,
hwEponOnuPortId
Integer32,
hwEponSrvProfOnuPortVlanMode
INTEGER,
hwEponSrvProfOnuPortAddToVlanId
Integer32,
hwEponSrvProfOnuPortDefaultVlanId
Integer32,
hwEponSrvProfOnuPortVlanRowStatus
RowStatus
}
hwEponOnuPortType OBJECT-TYPE
SYNTAX INTEGER { eth(1) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port type."
::= { hwEponSrvProfOnuPortVlanCfgEntry 1 }
hwEponOnuPortId OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port ID."
::= { hwEponSrvProfOnuPortVlanCfgEntry 2 }
hwEponSrvProfOnuPortVlanMode OBJECT-TYPE
SYNTAX INTEGER
{
transparent(1),
translation(2),
transmit(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN mode of an ONU port, 0, 2, or 3."
::= { hwEponSrvProfOnuPortVlanCfgEntry 3 }
hwEponSrvProfOnuPortAddToVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN IDs allowed by the ONU port."
::= { hwEponSrvProfOnuPortVlanCfgEntry 4 }
hwEponSrvProfOnuPortDefaultVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN ID of the ONU port."
::= { hwEponSrvProfOnuPortVlanCfgEntry 5 }
hwEponSrvProfOnuPortVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponSrvProfOnuPortVlanCfgEntry 51 }
hwEponSrvProfOnuPortVlanTranslationTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfOnuPortVlanTranslationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port's remote VLAN translation information table."
::= { hwEponProfileObjects 7 }
hwEponSrvProfOnuPortVlanTranslationEntry OBJECT-TYPE
SYNTAX HwEponSrvProfOnuPortVlanTranslationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ONU port's remote VLAN translation information entry."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuPortType, hwEponOnuPortId, hwEponSrvProfOnuPortVlanTranslationCvlanId }
::= { hwEponSrvProfOnuPortVlanTranslationTable 1 }
HwEponSrvProfOnuPortVlanTranslationEntry ::=
SEQUENCE {
hwEponSrvProfOnuPortVlanTranslationCvlanId
Integer32,
hwEponSrvProfOnuPortVlanTranslationSVlanId
Integer32,
hwEponSrvProfOnuPortVlanTranslationRowStatus
RowStatus
}
hwEponSrvProfOnuPortVlanTranslationCvlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"C-VLAN ID on the ONU port."
::= { hwEponSrvProfOnuPortVlanTranslationEntry 1 }
hwEponSrvProfOnuPortVlanTranslationSVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"S-VLAN ID on the ONU port."
::= { hwEponSrvProfOnuPortVlanTranslationEntry 2 }
hwEponSrvProfOnuPortVlanTranslationRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponSrvProfOnuPortVlanTranslationEntry 51 }
hwEponDbaProfileInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponDbaProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the DBA profile table. This table is
used to create a DBA profile,
and is used to modify or delete a DBA profile
which is not bound."
::= { hwEponProfileObjects 8 }
hwEponDbaProfileInfoEntry OBJECT-TYPE
SYNTAX HwEponDbaProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DBA profile entry."
INDEX { hwEponDbaProfileInfoNameIndex }
::= { hwEponDbaProfileInfoTable 1 }
HwEponDbaProfileInfoEntry ::=
SEQUENCE {
hwEponDbaProfileInfoNameIndex
DisplayString,
hwEponDbaTypeIndex
INTEGER,
hwEponDbaProfileFixedRate
Integer32,
hwEponDbaProfileAssuredRate
Integer32,
hwEponDbaProfileMaxRate
Integer32,
hwEponDbaProfileReferenceNum
Integer32,
hwEponDbaProfileEntryStatus
RowStatus
}
hwEponDbaProfileInfoNameIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"DBA profile name."
::= { hwEponDbaProfileInfoEntry 1 }
hwEponDbaTypeIndex OBJECT-TYPE
SYNTAX INTEGER
{
fix(1),
assure(2),
assureAndmax(3),
max(4),
fixAndassureAndMax(5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The DBA type index."
::= { hwEponDbaProfileInfoEntry 2 }
hwEponDbaProfileFixedRate OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Fixed bandwidth of the profile."
::= { hwEponDbaProfileInfoEntry 3 }
hwEponDbaProfileAssuredRate OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Assured bandwidth of the profile."
::= { hwEponDbaProfileInfoEntry 4 }
hwEponDbaProfileMaxRate OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Max bandwidth of the profile."
::= { hwEponDbaProfileInfoEntry 5 }
hwEponDbaProfileReferenceNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bound DBA profiles."
::= { hwEponDbaProfileInfoEntry 6 }
hwEponDbaProfileEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponDbaProfileInfoEntry 51 }
hwEponOnuSnmpProfileInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuSnmpProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EPON SNMP profile config table."
::= { hwEponProfileObjects 9 }
hwEponOnuSnmpProfileInfoEntry OBJECT-TYPE
SYNTAX HwEponOnuSnmpProfileInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EPON SNMP profile config table entry."
INDEX { hwEponOnuSnmpProfileInfoNameIndex }
::= { hwEponOnuSnmpProfileInfoTable 1 }
HwEponOnuSnmpProfileInfoEntry ::=
SEQUENCE {
hwEponOnuSnmpProfileInfoNameIndex
DisplayString,
hwEponOnuSnmpProfileVersion
INTEGER,
hwEponOnuSnmpProfileReadCommunityName
DisplayString,
hwEponOnuSnmpProfileWriteCommunityName
DisplayString,
hwEponOnuSnmpProfileTrapHostIp
IpAddress,
hwEponOnuSnmpProfileTrapHostSrcUdpPort
Integer32,
hwEponOnuSnmpProfileSecurityName
DisplayString,
hwEponOnuSnmpProfileRowStatus
RowStatus
}
hwEponOnuSnmpProfileInfoNameIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..31))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"SNMP profile name."
::= { hwEponOnuSnmpProfileInfoEntry 1 }
hwEponOnuSnmpProfileVersion OBJECT-TYPE
SYNTAX INTEGER
{
v1(1),
v2(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"SNMP version of the profile."
DEFVAL { 2 }
::= { hwEponOnuSnmpProfileInfoEntry 2 }
hwEponOnuSnmpProfileReadCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the read community."
::= { hwEponOnuSnmpProfileInfoEntry 3 }
hwEponOnuSnmpProfileWriteCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Name of the write community."
::= { hwEponOnuSnmpProfileInfoEntry 4 }
hwEponOnuSnmpProfileTrapHostIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP address of the host sending the trap."
::= { hwEponOnuSnmpProfileInfoEntry 5 }
hwEponOnuSnmpProfileTrapHostSrcUdpPort OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"UDP port number, ranging from 1 to 65535."
::= { hwEponOnuSnmpProfileInfoEntry 6 }
hwEponOnuSnmpProfileSecurityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The securityname of SNMP message."
::= { hwEponOnuSnmpProfileInfoEntry 7 }
hwEponOnuSnmpProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponOnuSnmpProfileInfoEntry 51 }
hwEponSrvProfOnuPortClassTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfOnuPortClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The configuration table of the EPON classification."
::= { hwEponProfileObjects 10 }
hwEponSrvProfOnuPortClassEntry OBJECT-TYPE
SYNTAX HwEponSrvProfOnuPortClassEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry of the configuration table of the Epon classification."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuClassifEthPortIndex, hwEponOnuPortClassRuleIndexId }
::= { hwEponSrvProfOnuPortClassTable 1 }
HwEponSrvProfOnuPortClassEntry ::=
SEQUENCE {
hwEponOnuClassifEthPortIndex
Integer32,
hwEponOnuPortClassRuleIndexId
Integer32,
hwEponOnuPortClassConditionNum
INTEGER,
hwEponOnuPortClassQueueIndexId
Integer32,
hwEponOnuPortClassPriMark
Integer32,
hwEponOnuPortClassFieldSelect1
INTEGER,
hwEponOnuPortClassOperator1
INTEGER,
hwEponOnuPortClassMatchValue1
DisplayString,
hwEponOnuPortClassFieldSelect2
INTEGER,
hwEponOnuPortClassOperator2
INTEGER,
hwEponOnuPortClassMatchValue2
DisplayString,
hwEponOnuPortClassFieldSelect3
INTEGER,
hwEponOnuPortClassOperator3
INTEGER,
hwEponOnuPortClassMatchValue3
DisplayString,
hwEponOnuPortClassFieldSelect4
INTEGER,
hwEponOnuPortClassOperator4
INTEGER,
hwEponOnuPortClassMatchValue4
DisplayString,
hwEponOnuPortClassProfileRowStatus
RowStatus
}
hwEponOnuClassifEthPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ETH port ID of the ONU ."
::= { hwEponSrvProfOnuPortClassEntry 1 }
hwEponOnuPortClassRuleIndexId OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the traffic classification rule."
::= { hwEponSrvProfOnuPortClassEntry 2 }
hwEponOnuPortClassConditionNum OBJECT-TYPE
SYNTAX INTEGER
{
one(1),
two(2),
three(3),
four(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of conditions in a rule"
::= { hwEponSrvProfOnuPortClassEntry 3 }
hwEponOnuPortClassQueueIndexId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ID of the queue."
::= { hwEponSrvProfOnuPortClassEntry 4 }
hwEponOnuPortClassPriMark OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the remark priority of the rule."
::= { hwEponSrvProfOnuPortClassEntry 5 }
hwEponOnuPortClassFieldSelect1 OBJECT-TYPE
SYNTAX INTEGER
{
dstMac(1),
srcMac(2),
ethPri(3),
vlanId(4),
ethType(5),
dstIp(6),
srcIp(7),
ipType(8),
ipTosDscp(9),
ipPrecedence(10),
srcPort(11),
dstPort(12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The field selector of the first condition."
::= { hwEponSrvProfOnuPortClassEntry 6 }
hwEponOnuPortClassOperator1 OBJECT-TYPE
SYNTAX INTEGER
{
neverMatch(1),
equal(2),
notEqual(3),
lessOrEqual(4),
greaterOrEqual(5),
exists(6),
notExists(7),
alwaysMatch(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The operator of the first condition."
::= { hwEponSrvProfOnuPortClassEntry 7 }
hwEponOnuPortClassMatchValue1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The match value of the first condition."
::= { hwEponSrvProfOnuPortClassEntry 8 }
hwEponOnuPortClassFieldSelect2 OBJECT-TYPE
SYNTAX INTEGER
{
dstMac(1),
srcMac(2),
ethPri(3),
vlanId(4),
ethType(5),
dstIp(6),
srcIp(7),
ipType(8),
ipTosDscp(9),
ipPrecedence(10),
srcPort(11),
dstPort(12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The field selector of the second condition."
::= { hwEponSrvProfOnuPortClassEntry 9 }
hwEponOnuPortClassOperator2 OBJECT-TYPE
SYNTAX INTEGER
{
neverMatch(1),
equal(2),
notEqual(3),
lessOrEqual(4),
greaterOrEqual(5),
exists(6),
notExists(7),
alwaysMatch(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The operator of the second condition."
::= { hwEponSrvProfOnuPortClassEntry 10 }
hwEponOnuPortClassMatchValue2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The match value of the second condition."
::= { hwEponSrvProfOnuPortClassEntry 11 }
hwEponOnuPortClassFieldSelect3 OBJECT-TYPE
SYNTAX INTEGER
{
dstMac(1),
srcMac(2),
ethPri(3),
vlanId(4),
ethType(5),
dstIp(6),
srcIp(7),
ipType(8),
ipTosDscp(9),
ipPrecedence(10),
srcPort(11),
dstPort(12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The field selector of the third condtion."
::= { hwEponSrvProfOnuPortClassEntry 12 }
hwEponOnuPortClassOperator3 OBJECT-TYPE
SYNTAX INTEGER
{
neverMatch(1),
equal(2),
notEqual(3),
lessOrEqual(4),
greaterOrEqual(5),
exists(6),
notExists(7),
alwaysMatch(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The operator of the third conditon."
::= { hwEponSrvProfOnuPortClassEntry 13 }
hwEponOnuPortClassMatchValue3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The match value of the third conditon."
::= { hwEponSrvProfOnuPortClassEntry 14 }
hwEponOnuPortClassFieldSelect4 OBJECT-TYPE
SYNTAX INTEGER
{
dstMac(1),
srcMac(2),
ethPri(3),
vlanId(4),
ethType(5),
dstIp(6),
srcIp(7),
ipType(8),
ipTosDscp(9),
ipPrecedence(10),
srcPort(11),
dstPort(12)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The field select of the fourth conditon."
::= { hwEponSrvProfOnuPortClassEntry 15 }
hwEponOnuPortClassOperator4 OBJECT-TYPE
SYNTAX INTEGER
{
neverMatch(1),
equal(2),
notEqual(3),
lessOrEqual(4),
greaterOrEqual(5),
exists(6),
notExists(7),
alwaysMatch(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The operator of the fourth conditon."
::= { hwEponSrvProfOnuPortClassEntry 16 }
hwEponOnuPortClassMatchValue4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The match value the fourth conditon."
::= { hwEponSrvProfOnuPortClassEntry 17 }
hwEponOnuPortClassProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponSrvProfOnuPortClassEntry 51 }
hwEponSrvProfOnuPortCfgCarTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponSrvProfOnuPortCfgCarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The service profile CAR config table."
::= { hwEponProfileObjects 11 }
hwEponSrvProfOnuPortCfgCarEntry OBJECT-TYPE
SYNTAX HwEponSrvProfOnuPortCfgCarEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service profile CAR config entry."
INDEX { hwEponOnuSrvProfNameIndex, hwEponOnuPortTypeIndex, hwEponOnuPortIdIndex, hwEponSrvProfOnuPortCarCfgDirection }
::= { hwEponSrvProfOnuPortCfgCarTable 1 }
HwEponSrvProfOnuPortCfgCarEntry ::=
SEQUENCE {
hwEponSrvProfOnuPortCarCfgDirection
INTEGER,
hwEponSrvProfOnuPortCarCfgCir
Integer32,
hwEponSrvProfOnuPortCarCfgPir
Integer32,
hwEponSrvProfOnuPortCarCfgCbs
Integer32,
hwEponSrvProfOnuPortCarCfgEbs
Integer32,
hwEponSrvProfOnuPortCarCfgRowStatus
RowStatus
}
hwEponSrvProfOnuPortCarCfgDirection OBJECT-TYPE
SYNTAX INTEGER
{
up(1),
down(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The direction of the CAR."
::= { hwEponSrvProfOnuPortCfgCarEntry 1 }
hwEponSrvProfOnuPortCarCfgCir OBJECT-TYPE
SYNTAX Integer32 (640..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The CIR on the ONU port."
::= { hwEponSrvProfOnuPortCfgCarEntry 2 }
hwEponSrvProfOnuPortCarCfgPir OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The PIR on the ONU port."
::= { hwEponSrvProfOnuPortCfgCarEntry 3 }
hwEponSrvProfOnuPortCarCfgCbs OBJECT-TYPE
SYNTAX Integer32 (1568..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The CBS on the ONU port."
::= { hwEponSrvProfOnuPortCfgCarEntry 4 }
hwEponSrvProfOnuPortCarCfgEbs OBJECT-TYPE
SYNTAX Integer32 (0..1000000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The EBS on the ONU port."
::= { hwEponSrvProfOnuPortCfgCarEntry 5 }
hwEponSrvProfOnuPortCarCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row status. This object is used to differentiate the creation, modification and deletion operations for an object."
::= { hwEponSrvProfOnuPortCfgCarEntry 51 }
hwEponStatisticObjects OBJECT IDENTIFIER ::= { hwEponObjects 4 }
hwEponOltStatisticTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OLT statisitcs table."
::= { hwEponStatisticObjects 1 }
hwEponOltStatisticEntry OBJECT-TYPE
SYNTAX HwEponOltStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OLT statistics entry."
INDEX { ifIndex , hwEponOnuIndex}
::= { hwEponOltStatisticTable 1 }
HwEponOltStatisticEntry ::=
SEQUENCE {
hwEponOltStatisticRecvDataFrames
Counter64,
hwEponOltStatisticRecvDataBytes
Counter64,
hwEponOltStatisticRecvMulticastFrames
Counter64,
hwEponOltStatisticRecvBoardcastFrames
Counter64,
hwEponOltStatisticRecvErrorFrames
Counter64,
hwEponOltStatisticRecvErrorBytes
Counter64,
hwEponOltStatisticRecv64ByteFrames
Counter64,
hwEponOltStatisticRecv65To127ByteFrames
Counter64,
hwEponOltStatisticRecv128To255ByteFrames
Counter64,
hwEponOltStatisticRecv256To511ByteFrames
Counter64,
hwEponOltStatisticRecv512To1023ByteFrames
Counter64,
hwEponOltStatisticRecv1024To1518ByteFrames
Counter64,
hwEponOltStatisticRecvOver1518ByteFrames
Counter64,
hwEponOltStatisticRecvUndersizeFrames
Counter64,
hwEponOltStatisticRecvOversizeFrames
Counter64,
hwEponOltStatisticRecvFcsErrorFrames
Counter64,
hwEponOltStatisticUniCastFrames
Counter64,
hwEponOltStatisticRecvOkFrameCnt
Counter64,
hwEponOltStatisticRecvOkByteCnt
Counter64,
hwEponOltStatisticTransDataFrames
Counter64,
hwEponOltStatisticTransDataBytes
Counter64,
hwEponOltStatisticTransUnicastFrames
Counter64,
hwEponOltStatisticTransMulticastFrames
Counter64,
hwEponOltStatisticTransBoardcastFrames
Counter64,
hwEponOltStatisticTrans64ByteFrames
Counter64,
hwEponOltStatisticTrans65To127ByteFrames
Counter64,
hwEponOltStatisticTrans128To255ByteFrames
Counter64,
hwEponOltStatisticTrans256To511ByteFrames
Counter64,
hwEponOltStatisticTrans512To1023ByteFrames
Counter64,
hwEponOltStatisticTrans1024To1518ByteFrames
Counter64,
hwEponOltStatisticTransOver1518ByteFrames
Counter64,
hwEponOltStatisticTransFcsErrorFrames
Counter64,
hwEponOltStatisticClear
INTEGER
}
hwEponOltStatisticRecvDataFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received data frames."
::= { hwEponOltStatisticEntry 1 }
hwEponOltStatisticRecvDataBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received data bytes."
::= { hwEponOltStatisticEntry 2 }
hwEponOltStatisticRecvMulticastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received multi-cast frames."
::= { hwEponOltStatisticEntry 3 }
hwEponOltStatisticRecvBoardcastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received board cast frames."
::= { hwEponOltStatisticEntry 4 }
hwEponOltStatisticRecvErrorFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received errored frames."
::= { hwEponOltStatisticEntry 5 }
hwEponOltStatisticRecvErrorBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received errored bytes."
::= { hwEponOltStatisticEntry 6 }
hwEponOltStatisticRecv64ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 64 bytes frames."
::= { hwEponOltStatisticEntry 7 }
hwEponOltStatisticRecv65To127ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 65-127 bytes frames."
::= { hwEponOltStatisticEntry 8 }
hwEponOltStatisticRecv128To255ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 128-255 bytes frames."
::= { hwEponOltStatisticEntry 9 }
hwEponOltStatisticRecv256To511ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 256~511 bytes frames."
::= { hwEponOltStatisticEntry 10 }
hwEponOltStatisticRecv512To1023ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 512-1023 bytes frames."
::= { hwEponOltStatisticEntry 11 }
hwEponOltStatisticRecv1024To1518ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 1024-1518 bytes frames."
::= { hwEponOltStatisticEntry 12 }
hwEponOltStatisticRecvOver1518ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames containing more than 1518 bytes."
::= { hwEponOltStatisticEntry 13 }
hwEponOltStatisticRecvUndersizeFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received undersize frames."
::= { hwEponOltStatisticEntry 14 }
hwEponOltStatisticRecvOversizeFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received oversize frames."
::= { hwEponOltStatisticEntry 15 }
hwEponOltStatisticRecvFcsErrorFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received FCS errored frames."
::= { hwEponOltStatisticEntry 16 }
hwEponOltStatisticUniCastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received unicast frames."
::= { hwEponOltStatisticEntry 17 }
hwEponOltStatisticRecvOkFrameCnt OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received correct frames."
::= { hwEponOltStatisticEntry 18 }
hwEponOltStatisticRecvOkByteCnt OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received correct bytes."
::= { hwEponOltStatisticEntry 19 }
hwEponOltStatisticTransDataFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent data frames."
::= { hwEponOltStatisticEntry 20 }
hwEponOltStatisticTransDataBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent data bytes."
::= { hwEponOltStatisticEntry 21 }
hwEponOltStatisticTransUnicastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent uni cast frames."
::= { hwEponOltStatisticEntry 22 }
hwEponOltStatisticTransMulticastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent multicast frames."
::= { hwEponOltStatisticEntry 23 }
hwEponOltStatisticTransBoardcastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent broadcast frames."
::= { hwEponOltStatisticEntry 24 }
hwEponOltStatisticTrans64ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 64 bytes frames."
::= { hwEponOltStatisticEntry 25 }
hwEponOltStatisticTrans65To127ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 65-127 bytes frames."
::= { hwEponOltStatisticEntry 26 }
hwEponOltStatisticTrans128To255ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 128-255 bytes frames."
::= { hwEponOltStatisticEntry 27 }
hwEponOltStatisticTrans256To511ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 256-511 bytes frames."
::= { hwEponOltStatisticEntry 28 }
hwEponOltStatisticTrans512To1023ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 512-1023 bytes frames."
::= { hwEponOltStatisticEntry 29 }
hwEponOltStatisticTrans1024To1518ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 1024-1518 bytes frames."
::= { hwEponOltStatisticEntry 30 }
hwEponOltStatisticTransOver1518ByteFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent frames containing more than 1518 bytes."
::= { hwEponOltStatisticEntry 31 }
hwEponOltStatisticTransFcsErrorFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent FCS errored bytes."
::= { hwEponOltStatisticEntry 32 }
hwEponOltStatisticClear OBJECT-TYPE
SYNTAX INTEGER { clear(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the statistics."
::= { hwEponOltStatisticEntry 33 }
hwEponOnuPonStatisticTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuPonStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT LLID statistics table."
::= { hwEponStatisticObjects 2 }
hwEponOnuPonStatisticEntry OBJECT-TYPE
SYNTAX HwEponOnuPonStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT LLID statistics entry."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuPonStatisticTable 1 }
HwEponOnuPonStatisticEntry ::=
SEQUENCE {
hwEponOnuPonStatisticRcv1024To1518byteFrm
Counter64,
hwEponOnuPonStatisticRcv128To255byteFrm
Counter64,
hwEponOnuPonStatisticRcv256To511byteFrm
Counter64,
hwEponOnuPonStatisticRcv512To1023byteFrm
Counter64,
hwEponOnuPonStatisticRcv64byteFrm
Counter64,
hwEponOnuPonStatisticRcv65To127byteFrm
Counter64,
hwEponOnuPonStatisticRcvBcFrame
Counter64,
hwEponOnuPonStatisticRcvByte
Counter64,
hwEponOnuPonStatisticRcvCrc8Err
Counter64,
hwEponOnuPonStatisticRcvDelayByte
Counter64,
hwEponOnuPonStatisticRcvDelayMax
Counter64,
hwEponOnuPonStatisticRcvDelayThreshold
Counter64,
hwEponOnuPonStatisticRcvDropByte
Counter64,
hwEponOnuPonStatisticRcvDropFrm
Counter64,
hwEponOnuPonStatisticRcvErrFrm
Counter64,
hwEponOnuPonStatisticRcvErrOntDestinedByte
Counter64,
hwEponOnuPonStatisticRcvFcsErr
Counter64,
hwEponOnuPonStatisticRcvFrame
Counter64,
hwEponOnuPonStatisticRcvGreatThan1518byteFrm
Counter64,
hwEponOnuPonStatisticRcvInvalidSldFrm
Counter64,
hwEponOnuPonStatisticRcvLaserPower
Counter64,
hwEponOnuPonStatisticRcvLineCodeErr
Counter64,
hwEponOnuPonStatisticRcvMcFrame
Counter64,
hwEponOnuPonStatisticRcvOntDestinedByte
Counter64,
hwEponOnuPonStatisticRcvUcFrame
Counter64,
hwEponOnuPonStatisticRcvUndersizeFrm
Counter64,
hwEponOnuPonStatisticSend1024To1518byteFrm
Counter64,
hwEponOnuPonStatisticSend128To255byteFrm
Counter64,
hwEponOnuPonStatisticSend256To511byteFrm
Counter64,
hwEponOnuPonStatisticSend512To1023byteFrm
Counter64,
hwEponOnuPonStatisticSend64byteFrm
Counter64,
hwEponOnuPonStatisticSend65To127byteFrm
Counter64,
hwEponOnuPonStatisticSendBcFrame
Counter64,
hwEponOnuPonStatisticSendByte
Counter64,
hwEponOnuPonStatisticSendDelayByte
Counter64,
hwEponOnuPonStatisticSendDelayMax
Counter64,
hwEponOnuPonStatisticSendDelayThreshold
Counter64,
hwEponOnuPonStatisticSendDropByte
Counter64,
hwEponOnuPonStatisticSendDropFrm
Counter64,
hwEponOnuPonStatisticSendFrame
Counter64,
hwEponOnuPonStatisticSendGreatThan1518byteFrm
Counter64,
hwEponOnuPonStatisticSendMcFrame
Counter64,
hwEponOnuPonStatisticSendUcFrame
Counter64,
hwEponOnuPonStatisticSendUnusedByte
Counter64,
hwEponOnuPonStatisticClear
INTEGER
}
hwEponOnuPonStatisticRcv1024To1518byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 1024-1518 bytes frames."
::= { hwEponOnuPonStatisticEntry 1 }
hwEponOnuPonStatisticRcv128To255byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 128-255 bytes frames."
::= { hwEponOnuPonStatisticEntry 2 }
hwEponOnuPonStatisticRcv256To511byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 256-511 bytes frames."
::= { hwEponOnuPonStatisticEntry 3 }
hwEponOnuPonStatisticRcv512To1023byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 512-1023 bytes frames."
::= { hwEponOnuPonStatisticEntry 4 }
hwEponOnuPonStatisticRcv64byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 64 bytes frames."
::= { hwEponOnuPonStatisticEntry 5 }
hwEponOnuPonStatisticRcv65To127byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 65-127 bytes frames."
::= { hwEponOnuPonStatisticEntry 6 }
hwEponOnuPonStatisticRcvBcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received broad cast frames."
::= { hwEponOnuPonStatisticEntry 7 }
hwEponOnuPonStatisticRcvByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received bytes."
::= { hwEponOnuPonStatisticEntry 8 }
hwEponOnuPonStatisticRcvCrc8Err OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received CRC errored bytes."
::= { hwEponOnuPonStatisticEntry 9 }
hwEponOnuPonStatisticRcvDelayByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received delayed bytes."
::= { hwEponOnuPonStatisticEntry 10 }
hwEponOnuPonStatisticRcvDelayMax OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received delayed MAX bytes."
::= { hwEponOnuPonStatisticEntry 11 }
hwEponOnuPonStatisticRcvDelayThreshold OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received delayed threshold bytes."
::= { hwEponOnuPonStatisticEntry 12 }
hwEponOnuPonStatisticRcvDropByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received dropped bytes."
::= { hwEponOnuPonStatisticEntry 13 }
hwEponOnuPonStatisticRcvDropFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received dropped frames."
::= { hwEponOnuPonStatisticEntry 14 }
hwEponOnuPonStatisticRcvErrFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received errored frames."
::= { hwEponOnuPonStatisticEntry 15 }
hwEponOnuPonStatisticRcvErrOntDestinedByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received errored destined bytes."
::= { hwEponOnuPonStatisticEntry 16 }
hwEponOnuPonStatisticRcvFcsErr OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received FEC errored frames."
::= { hwEponOnuPonStatisticEntry 17 }
hwEponOnuPonStatisticRcvFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames."
::= { hwEponOnuPonStatisticEntry 18 }
hwEponOnuPonStatisticRcvGreatThan1518byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames containing more than 1518 bytes."
::= { hwEponOnuPonStatisticEntry 19 }
hwEponOnuPonStatisticRcvInvalidSldFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received invalid SID frames."
::= { hwEponOnuPonStatisticEntry 20 }
hwEponOnuPonStatisticRcvLaserPower OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received laser power frames."
::= { hwEponOnuPonStatisticEntry 21 }
hwEponOnuPonStatisticRcvLineCodeErr OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames incorrectly coded."
::= { hwEponOnuPonStatisticEntry 22 }
hwEponOnuPonStatisticRcvMcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received multicast frames."
::= { hwEponOnuPonStatisticEntry 23 }
hwEponOnuPonStatisticRcvOntDestinedByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received ONU destined bytes."
::= { hwEponOnuPonStatisticEntry 24 }
hwEponOnuPonStatisticRcvUcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received unicast frames."
::= { hwEponOnuPonStatisticEntry 25 }
hwEponOnuPonStatisticRcvUndersizeFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received under size frames."
::= { hwEponOnuPonStatisticEntry 26 }
hwEponOnuPonStatisticSend1024To1518byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 1024-1518 bytes frames."
::= { hwEponOnuPonStatisticEntry 27 }
hwEponOnuPonStatisticSend128To255byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 128-255 bytes frames."
::= { hwEponOnuPonStatisticEntry 28 }
hwEponOnuPonStatisticSend256To511byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 256-511 bytes frames."
::= { hwEponOnuPonStatisticEntry 29 }
hwEponOnuPonStatisticSend512To1023byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 512-1023 bytes frames."
::= { hwEponOnuPonStatisticEntry 30 }
hwEponOnuPonStatisticSend64byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 64 bytes frames."
::= { hwEponOnuPonStatisticEntry 31 }
hwEponOnuPonStatisticSend65To127byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent 65-127 bytes frames."
::= { hwEponOnuPonStatisticEntry 32 }
hwEponOnuPonStatisticSendBcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent broadcast frames."
::= { hwEponOnuPonStatisticEntry 33 }
hwEponOnuPonStatisticSendByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent bytes."
::= { hwEponOnuPonStatisticEntry 34 }
hwEponOnuPonStatisticSendDelayByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent delayed bytes."
::= { hwEponOnuPonStatisticEntry 35 }
hwEponOnuPonStatisticSendDelayMax OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent delayed MAX bytes."
::= { hwEponOnuPonStatisticEntry 36 }
hwEponOnuPonStatisticSendDelayThreshold OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent delayed threshold bytes."
::= { hwEponOnuPonStatisticEntry 37 }
hwEponOnuPonStatisticSendDropByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent dropped bytes."
::= { hwEponOnuPonStatisticEntry 38 }
hwEponOnuPonStatisticSendDropFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent dropped frames."
::= { hwEponOnuPonStatisticEntry 39 }
hwEponOnuPonStatisticSendFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent delayed bytes."
::= { hwEponOnuPonStatisticEntry 40 }
hwEponOnuPonStatisticSendGreatThan1518byteFrm OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent frames containing more than 1518 bytes."
::= { hwEponOnuPonStatisticEntry 41 }
hwEponOnuPonStatisticSendMcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent multicast frames."
::= { hwEponOnuPonStatisticEntry 42 }
hwEponOnuPonStatisticSendUcFrame OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent unicast frames."
::= { hwEponOnuPonStatisticEntry 43 }
hwEponOnuPonStatisticSendUnusedByte OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent unused bytes."
::= { hwEponOnuPonStatisticEntry 44 }
hwEponOnuPonStatisticClear OBJECT-TYPE
SYNTAX INTEGER { clear(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the statistics."
::= { hwEponOnuPonStatisticEntry 45 }
hwEponOnuUniStatisticTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuUniStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU ETH port statistics table."
::= { hwEponStatisticObjects 3 }
hwEponOnuUniStatisticEntry OBJECT-TYPE
SYNTAX HwEponOnuUniStatisticEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU ETH port statistics entry."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuEthPortId }
::= { hwEponOnuUniStatisticTable 1 }
HwEponOnuUniStatisticEntry ::=
SEQUENCE {
hwEponOnuUniStatisticRecvFrames
Counter64,
hwEponOnuUniStatisticRecvMulticastFrames
Counter64,
hwEponOnuUniStatisticRecvBroadcastFrames
Counter64,
hwEponOnuUniStatisticRecv64OctetFrames
Counter64,
hwEponOnuUniStatisticRecv65To127OctetFrames
Counter64,
hwEponOnuUniStatisticRecv128To255OctetFrames
Counter64,
hwEponOnuUniStatisticRecv256To511OctetFrames
Counter64,
hwEponOnuUniStatisticRecv512To1023OctetFrames
Counter64,
hwEponOnuUniStatisticRecv1024To1518OctetFrames
Counter64,
hwEponOnuUniStatisticRecvUndersizeFrames
Counter64,
hwEponOnuUniStatisticRecvTooLongFrames
Counter64,
hwEponOnuUniStatisticTransDropFrames
Counter64,
hwEponOnuUniStatisticTransFrames
Counter64,
hwEponOnuUniStatisticTransMtuExceededDiscardFrames
Counter64,
hwEponOnuUniStatisticClear
INTEGER
}
hwEponOnuUniStatisticRecvFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received frames."
::= { hwEponOnuUniStatisticEntry 1 }
hwEponOnuUniStatisticRecvMulticastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received multicast frames."
::= { hwEponOnuUniStatisticEntry 2 }
hwEponOnuUniStatisticRecvBroadcastFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received boardcast frames."
::= { hwEponOnuUniStatisticEntry 3 }
hwEponOnuUniStatisticRecv64OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 64 bytes frames."
::= { hwEponOnuUniStatisticEntry 4 }
hwEponOnuUniStatisticRecv65To127OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 65-127 bytes frames."
::= { hwEponOnuUniStatisticEntry 5 }
hwEponOnuUniStatisticRecv128To255OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 128-255 bytes frames."
::= { hwEponOnuUniStatisticEntry 6 }
hwEponOnuUniStatisticRecv256To511OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 256-511 bytes frames."
::= { hwEponOnuUniStatisticEntry 7 }
hwEponOnuUniStatisticRecv512To1023OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 512-1023 bytes frames."
::= { hwEponOnuUniStatisticEntry 8 }
hwEponOnuUniStatisticRecv1024To1518OctetFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received 1024-1518 bytes frames."
::= { hwEponOnuUniStatisticEntry 9 }
hwEponOnuUniStatisticRecvUndersizeFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received undersize frames."
::= { hwEponOnuUniStatisticEntry 10 }
hwEponOnuUniStatisticRecvTooLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received oversize frames."
::= { hwEponOnuUniStatisticEntry 11 }
hwEponOnuUniStatisticTransDropFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received discarded frames."
::= { hwEponOnuUniStatisticEntry 12 }
hwEponOnuUniStatisticTransFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sent frames."
::= { hwEponOnuUniStatisticEntry 13 }
hwEponOnuUniStatisticTransMtuExceededDiscardFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frames failed to be sent due to oversize."
::= { hwEponOnuUniStatisticEntry 14 }
hwEponOnuUniStatisticClear OBJECT-TYPE
SYNTAX INTEGER { clear(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the statistics."
::= { hwEponOnuUniStatisticEntry 15 }
hwEponDisplayAlarmObjects OBJECT IDENTIFIER ::= { hwEponObjects 5 }
hwEponOnuAlarmStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the ONU alarm state table.
This table is used to query the alarm state of an ONU."
::= { hwEponDisplayAlarmObjects 1 }
hwEponOnuAlarmStateEntry OBJECT-TYPE
SYNTAX HwEponOnuAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU alarm state."
INDEX { ifIndex, hwEponOnuIndex }
::= { hwEponOnuAlarmStateTable 1 }
HwEponOnuAlarmStateEntry ::=
SEQUENCE {
hwEponOnuAlarmStateKeyExchangeFail
INTEGER,
hwEponOnuAlarmStateDyingGasp
INTEGER,
hwEponOnuAlarmStateLinkFault
INTEGER,
hwEponOnuFirmWareLoadStateSucc
INTEGER,
hwEponOnuFirmWareLoadStateFault
INTEGER
}
hwEponOnuAlarmStateKeyExchangeFail OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fail to exchange key."
::= { hwEponOnuAlarmStateEntry 1 }
hwEponOnuAlarmStateDyingGasp OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The dying-gasp of ONU is generated."
::= { hwEponOnuAlarmStateEntry 2 }
hwEponOnuAlarmStateLinkFault OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link fault occurs at OLT."
::= { hwEponOnuAlarmStateEntry 3 }
hwEponOnuFirmWareLoadStateSucc OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loading ONU firmware successfully."
::= { hwEponOnuAlarmStateEntry 4 }
hwEponOnuFirmWareLoadStateFault OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fail to load ONU firmwar."
::= { hwEponOnuAlarmStateEntry 5 }
hwEponOnuUniAlarmStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOnuUniAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the UNI of an ONU alarm state table.
This table is used to query the alarm state of the UNI of an ONU."
::= { hwEponDisplayAlarmObjects 2 }
hwEponOnuUniAlarmStateEntry OBJECT-TYPE
SYNTAX HwEponOnuUniAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ONU alarm state."
INDEX { ifIndex, hwEponOnuIndex, hwEponOnuPortId }
::= { hwEponOnuUniAlarmStateTable 1 }
HwEponOnuUniAlarmStateEntry ::=
SEQUENCE {
hwEponOnuUniAlarmStateTransmitFail
INTEGER,
hwEponOnuUniAlarmStateLos
INTEGER
}
hwEponOnuUniAlarmStateTransmitFail OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fail to transmit."
::= { hwEponOnuUniAlarmStateEntry 2 }
hwEponOnuUniAlarmStateLos OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The loss of frame of ONU occurs."
::= { hwEponOnuUniAlarmStateEntry 3 }
hwEponOltAlarmStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEponOltAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the OLT alarm state table.
This table is used to query the alarm state of an OLT."
::= { hwEponDisplayAlarmObjects 3 }
hwEponOltAlarmStateEntry OBJECT-TYPE
SYNTAX HwEponOltAlarmStateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OLT alarm state entry."
INDEX { ifIndex }
::= { hwEponOltAlarmStateTable 1 }
HwEponOltAlarmStateEntry ::=
SEQUENCE {
hwEponOltAlarmStateDegrade
INTEGER
}
hwEponOltAlarmStateDegrade OBJECT-TYPE
SYNTAX INTEGER
{
yes(1),
no(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The dying-gasp of ONU is generated."
::= { hwEponOltAlarmStateEntry 1 }
hwEponTrapObjects OBJECT IDENTIFIER ::= { hwEponObjects 6 }
hwEponSlotIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Slot ID of the EPON interface."
::= { hwEponTrapObjects 1 }
hwEponCardIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Card ID of the EPON interface."
::= { hwEponTrapObjects 2 }
hwEponPortIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Port ID of the EPON interface."
::= { hwEponTrapObjects 3 }
hwEponTrapOnuId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ONU ID."
::= { hwEponTrapObjects 4 }
hwEponTrapMac OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"MAC address of the ONU."
::= { hwEponTrapObjects 5 }
hwEponTrapPwd OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ONU password."
::= { hwEponTrapObjects 6 }
hwEponTrap OBJECT IDENTIFIER ::= { hwEponObjects 7 }
hwEponOltAlarmLosTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex }
STATUS current
DESCRIPTION
"Los alarm."
::= { hwEponTrap 1 }
hwEponOltAlarmLosResumeTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex }
STATUS current
DESCRIPTION
"Los alarm resume alarm."
::= { hwEponTrap 2 }
hwEponOltAutoFindTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex, hwEponTrapMac, hwEponTrapPwd
}
STATUS current
DESCRIPTION
"ONU auto finded alarm."
::= { hwEponTrap 3 }
hwEponOltAlarmTransmitFaultTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex }
STATUS current
DESCRIPTION
"OLT send failed."
::= { hwEponTrap 4 }
hwEponOnuAlarmPwdConlictTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex, hwEponTrapOnuId }
STATUS current
DESCRIPTION
"Regist conflicted by password alarm."
::= { hwEponTrap 5 }
hwEponOnuOnlineTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex, hwEponTrapOnuId, hwEponTrapMac,
hwEponTrapPwd }
STATUS current
DESCRIPTION
"ONU on line alarm."
::= { hwEponTrap 6 }
hwEponOnuOfflineTrap NOTIFICATION-TYPE
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex, hwEponTrapOnuId, hwEponTrapMac,
hwEponTrapPwd }
STATUS current
DESCRIPTION
"ONU off line alarm."
::= { hwEponTrap 7 }
hwEponConformance OBJECT IDENTIFIER ::= { hwEponObjects 8 }
hwEponCompliances OBJECT IDENTIFIER ::= { hwEponConformance 1 }
hwEponCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP entities which implement
the HUAWEI-EPON-MIB."
MODULE -- this module
MANDATORY-GROUPS { hwEponGlobalGroup, hwEponControlGroup, hwEponProfileGroup, hwEponStatisticGroup, hwEponDisplayAlarmObjectsGroup,
hwEponTrapObjectsGroup, hwEponTrapGroup }
::= { hwEponCompliances 1 }
hwEponGroups OBJECT IDENTIFIER ::= { hwEponConformance 2 }
hwEponGlobalGroup OBJECT-GROUP
OBJECTS { hwEponAutoFindOnuAge, hwEponCtcOuiId, hwEponChangePasswordAge }
STATUS current
DESCRIPTION
"The collection of objects which are used to configure the
EPON implementation behavior.
This group is mandatory for agents which implement the EPON."
::= { hwEponGroups 1 }
hwEponControlGroup OBJECT-GROUP
OBJECTS { hwEponOltControlfarthest, hwEponOltControlAutofindOnuEnable, hwEponOltControlStatus, hwEponOltControlUpStreamBandWidth,
hwEponOltControlDownStreamBandWidth, hwEponOnuId, hwEponOnuAuthMode, hwEponOnuMacAddress, hwEponOnuPassword, hwEponOnuTimeout,
hwEponOnuManagementMode, hwEponOnuLineProfName, hwEponOnuServiceProfName, hwEponOnuActiveStatus,hwEponOnuDescription, hwEponOnuVendorId,
hwEponOnuModel, hwEponOnuOnuIdentifier, hwEponOnuHardwareVersion, hwEponOnuSoftwareVersion, hwEponOnuChipVenderId,
hwEponOnuChipModel, hwEponOnuChipVersion, hwEponOnuChipDesignDate, hwEponOnuFirmwareVersion,
hwEponOnuReset, hwEponOnuReRegister, hwEponOnuReDiscovery, hwEponOnuRunStatus, hwEponOnuDistance,
hwEponOnuRtt, hwEponOnuLastUpTime, hwEponOnuLastDownTime,
hwEponOnuLastDownCause, hwEponAutoFindOnuInfoMacAddress, hwEponAutoFindOnuInfoPasswordValue, hwEponOnuPotsPortNum, hwEponOnuFePortsNum,
hwEponOnuGePortsNum, hwEponOnuTdmPortsNum, hwEponOnuFecSupport, hwEponOnuSupportBackupBattery, hwEponOnuUpQueueNum,
hwEponOnuUpQueueNumPerPort, hwEponOnuDownQueueNum, hwEponOnuDownQueueNumPerPort, hwEponOnuFePortList, hwEponOnuGePortList,
hwEponOnuSupportMulticastQuickLeave, hwEponOnuIpAddress, hwEponOnuNetMask, hwEponOnuNetGateway, hwEponOnuEthOperateStatus,
hwEponOnuEthFlowcontrolSwitch, hwEponOnuTdmPortOperateStatus, hwEponOnuPotsPortOperateStatus, hwEponOltPortDefaultVlanId, hwEponOltPortDefaultVlanBatch,
hwEponOltPortDefaultVlanOnuStartId, hwEponOltPortDefaultVlanOnuEndId, hwEponOnuCarProfileNameIndex, hwEponOnuTrafficPolicyNameIndex, hwEponVlanStackingOrMapping,hwEponOnuDextVlanId,
hwEponOnuDintVlanId, hwEponOnuPopExtVlanId, hwEponOnuVlanCopyPri, hwEponOnuIntVlanRemarkPri, hwEponOnuExtVlanRemarkPri,
hwEponOnuIntVlanPri, hwEponOnuExtVlanPri, hwEponVlanMappingBatch, hwEponVlanMappingOnuStartId, hwEponVlanMappingOnuEndId,
hwEponOnuUserMacAddress, hwEponOnuUserMacAddressNumber, hwEponOnuForwardAction, hwEponOnuAlarmAction, hwEponOnuRowStatus,
hwEponOnuCfgCarRowStatus, hwEponOltPortDefaultVlanRowStatus, hwEponVlanMappingRowStatus, hwEponOnuIpRowStates, hwEponOltPortStaticMacRowStatus,
hwEponOnuMacLimitRowStatus, hwEponOnuIpManageVlan }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON implementation behavior."
::= { hwEponGroups 2 }
hwEponProfileGroup OBJECT-GROUP
OBJECTS { hwEponLineProfileBindNum, hwEponLineProfileDbaProfileName, hwEponLineProfileEncryptMode, hwEponLineProfileQueueSetIndex1Threshold, hwEponLineProfileQueueSetIndex2Threshold,
hwEponLineProfileQueueSetIndex3Threshold, hwEponOnuSrvProfileBindNum, hwEponSrvProfileMulticastMode, hwEponSrvProfileFecMode, hwEponSrvProfileMulticastQuickLeaveSwitch,
hwEponSrvProfOnuPortCfgMaxMacAddressNum, hwEponSrvProfOnuPortCfgMulticastStripSwitch, hwEponDbaProfileFixedRate, hwEponDbaProfileAssuredRate, hwEponDbaProfileMaxRate,
hwEponDbaProfileReferenceNum, hwEponDbaProfileEntryStatus, hwEponOnuSnmpProfileVersion, hwEponOnuSnmpProfileReadCommunityName, hwEponOnuSnmpProfileWriteCommunityName,
hwEponOnuSnmpProfileTrapHostIp, hwEponOnuSnmpProfileTrapHostSrcUdpPort, hwEponOnuSnmpProfileSecurityName, hwEponOnuPortClassPriMark, hwEponOnuPortClassConditionNum,
hwEponOnuPortClassFieldSelect1, hwEponOnuPortClassOperator1, hwEponOnuPortClassMatchValue1, hwEponOnuPortClassFieldSelect2, hwEponOnuPortClassOperator2,
hwEponOnuPortClassMatchValue2, hwEponSrvProfOnuPortCarCfgCir, hwEponOnuPortClassFieldSelect3, hwEponOnuPortClassOperator3, hwEponOnuPortClassMatchValue3,
hwEponSrvProfOnuPortCarCfgPir, hwEponSrvProfOnuPortCarCfgCbs, hwEponSrvProfOnuPortCarCfgEbs, hwEponOnuPortClassQueueIndexId, hwEponLineProfileRowStatus,
hwEponOnuSrvProfileRowStatus, hwEponOnuSnmpProfileRowStatus, hwEponSrvProfOnuPortCarCfgRowStatus, hwEponOnuPortClassProfileRowStatus, hwEponSrvProfMulticastVlanCfgRowStatus,
hwEponOnuSnmpProfName, hwEponDbaTypeIndex, hwEponOnuPortClassFieldSelect4, hwEponOnuPortClassOperator4, hwEponOnuPortClassMatchValue4,
hwEponSrvProfOnuPortVlanMode, hwEponSrvProfOnuPortVlanTranslationRowStatus, hwEponSrvProfOnuPortDefaultVlanId, hwEponSrvProfOnuPortVlanRowStatus, hwEponSrvProfOnuPortVlanTranslationSVlanId,
hwEponSrvProfOnuPortAddToVlanId }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON profile behavior."
::= { hwEponGroups 3 }
hwEponStatisticGroup OBJECT-GROUP
OBJECTS {hwEponOltStatisticRecvDataFrames,hwEponOltStatisticRecvDataBytes,hwEponOltStatisticRecvMulticastFrames,hwEponOltStatisticRecvBoardcastFrames
,hwEponOltStatisticRecvErrorFrames,hwEponOltStatisticRecvErrorBytes,hwEponOltStatisticRecv64ByteFrames,hwEponOltStatisticRecv65To127ByteFrames
,hwEponOltStatisticRecv128To255ByteFrames,hwEponOltStatisticRecv256To511ByteFrames,hwEponOltStatisticRecv512To1023ByteFrames,
hwEponOltStatisticRecv1024To1518ByteFrames,hwEponOltStatisticRecvOver1518ByteFrames,hwEponOltStatisticRecvUndersizeFrames,hwEponOltStatisticRecvOversizeFrames,
hwEponOltStatisticRecvFcsErrorFrames,hwEponOltStatisticUniCastFrames, hwEponOltStatisticRecvOkFrameCnt,hwEponOltStatisticRecvOkByteCnt,
hwEponOltStatisticTransDataFrames,hwEponOltStatisticTransDataBytes,hwEponOltStatisticTransUnicastFrames,hwEponOltStatisticTransMulticastFrames,
hwEponOltStatisticTransBoardcastFrames,hwEponOltStatisticTrans64ByteFrames,hwEponOltStatisticTrans65To127ByteFrames,hwEponOltStatisticTrans128To255ByteFrames,
hwEponOltStatisticTrans256To511ByteFrames,hwEponOltStatisticTrans512To1023ByteFrames,hwEponOltStatisticTrans1024To1518ByteFrames,
hwEponOltStatisticTransOver1518ByteFrames, hwEponOltStatisticTransFcsErrorFrames,hwEponOltStatisticClear,hwEponOnuPonStatisticRcv1024To1518byteFrm,
hwEponOnuPonStatisticRcv128To255byteFrm,hwEponOnuPonStatisticRcv256To511byteFrm,hwEponOnuPonStatisticRcv512To1023byteFrm,hwEponOnuPonStatisticRcv64byteFrm,
hwEponOnuPonStatisticRcv65To127byteFrm,hwEponOnuPonStatisticRcvBcFrame,hwEponOnuPonStatisticRcvByte,hwEponOnuPonStatisticRcvCrc8Err,
hwEponOnuPonStatisticRcvDelayByte ,hwEponOnuPonStatisticRcvDelayMax ,hwEponOnuPonStatisticRcvDelayThreshold,hwEponOnuPonStatisticRcvDropByte,
hwEponOnuPonStatisticRcvDropFrm,hwEponOnuPonStatisticRcvErrFrm,hwEponOnuPonStatisticRcvErrOntDestinedByte ,hwEponOnuPonStatisticRcvFcsErr ,
hwEponOnuPonStatisticRcvFrame, hwEponOnuPonStatisticRcvGreatThan1518byteFrm , hwEponOnuPonStatisticRcvInvalidSldFrm, hwEponOnuPonStatisticRcvLaserPower,
hwEponOnuPonStatisticRcvLineCodeErr,hwEponOnuPonStatisticRcvMcFrame, hwEponOnuPonStatisticRcvOntDestinedByte,hwEponOnuPonStatisticRcvUcFrame,
hwEponOnuPonStatisticRcvUndersizeFrm, hwEponOnuPonStatisticSend1024To1518byteFrm,hwEponOnuPonStatisticSend128To255byteFrm ,hwEponOnuPonStatisticSend256To511byteFrm,
hwEponOnuPonStatisticSend512To1023byteFrm , hwEponOnuPonStatisticSend64byteFrm ,hwEponOnuPonStatisticSend65To127byteFrm ,hwEponOnuPonStatisticSendBcFrame,
hwEponOnuPonStatisticSendByte , hwEponOnuPonStatisticSendDelayByte,hwEponOnuPonStatisticSendDelayMax ,hwEponOnuPonStatisticSendDelayThreshold,
hwEponOnuPonStatisticSendDropByte,hwEponOnuPonStatisticSendDropFrm ,hwEponOnuPonStatisticSendFrame ,hwEponOnuPonStatisticSendGreatThan1518byteFrm,
hwEponOnuPonStatisticSendMcFrame ,hwEponOnuPonStatisticSendUcFrame,hwEponOnuPonStatisticSendUnusedByte , hwEponOnuPonStatisticClear,
hwEponOnuUniStatisticRecvFrames,hwEponOnuUniStatisticRecvMulticastFrames,hwEponOnuUniStatisticRecvBroadcastFrames,hwEponOnuUniStatisticRecv64OctetFrames,
hwEponOnuUniStatisticRecv65To127OctetFrames,hwEponOnuUniStatisticRecv128To255OctetFrames,hwEponOnuUniStatisticRecv256To511OctetFrames,
hwEponOnuUniStatisticRecv512To1023OctetFrames,hwEponOnuUniStatisticRecv1024To1518OctetFrames,hwEponOnuUniStatisticRecvUndersizeFrames,
hwEponOnuUniStatisticRecvTooLongFrames,hwEponOnuUniStatisticTransDropFrames,hwEponOnuUniStatisticTransFrames,hwEponOnuUniStatisticTransMtuExceededDiscardFrames,
hwEponOnuUniStatisticClear }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON Statistic behavior."
::= { hwEponGroups 4 }
hwEponDisplayAlarmObjectsGroup OBJECT-GROUP
OBJECTS {hwEponOnuAlarmStateKeyExchangeFail,hwEponOnuAlarmStateDyingGasp, hwEponOnuAlarmStateLinkFault, hwEponOnuFirmWareLoadStateSucc, hwEponOnuFirmWareLoadStateFault,
hwEponOltAlarmStateDegrade, hwEponOnuUniAlarmStateTransmitFail, hwEponOnuUniAlarmStateLos }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON alarm behavior."
::= { hwEponGroups 5 }
hwEponTrapObjectsGroup OBJECT-GROUP
OBJECTS { hwEponSlotIndex, hwEponCardIndex, hwEponPortIndex, hwEponTrapOnuId, hwEponTrapMac,
hwEponTrapPwd }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON trap object behavior."
::= { hwEponGroups 6 }
hwEponTrapGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwEponOltAlarmLosTrap, hwEponOltAlarmLosResumeTrap, hwEponOltAutoFindTrap, hwEponOltAlarmTransmitFaultTrap,
hwEponOnuAlarmPwdConlictTrap, hwEponOnuOnlineTrap, hwEponOnuOfflineTrap }
STATUS current
DESCRIPTION
"The collection of objects which are used to control the EPON trap behavior."
::= { hwEponGroups 7 }
END
--