mibs/MIBS/huawei/HUAWEI-ERPS-MIB
2023-12-05 12:25:34 +01:00

1085 lines
37 KiB
Plaintext

-- =================================================================
-- Copyright (C) 2016 by HUAWEI TECHNOLOGIES. All rights reserved
--
-- Description: ITU-T G.8032 huawei mib define
-- Reference: ITU-T G.8032/Y.1344
-- Version: V2.13
-- History:
-- <fenghaisheng 61958>,<2011.07.05>,<create>
-- =================================================================
HUAWEI-ERPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
EnabledStatus
FROM P-BRIDGE-MIB
VlanId
FROM Q-BRIDGE-MIB
OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
InterfaceIndex, ifName
FROM IF-MIB
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY,
NOTIFICATION-TYPE,TimeTicks,Counter32
FROM SNMPv2-SMI
RowStatus,DisplayString
FROM SNMPv2-TC;
-- 1.3.6.1.4.1.2011.5.25.256
hwErpsMIB MODULE-IDENTITY
LAST-UPDATED "201610280000Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
"
DESCRIPTION
"The private mib file includes the general extent
information of the device.hwDatacomm(25).hwErpsMIB.
"
REVISION "201610280000Z"
DESCRIPTION
"fix the errors points of hwErpsNotifications."
REVISION "201308310000Z"
DESCRIPTION
"fix the errors checked by a tool."
REVISION "201306280001Z"
DESCRIPTION
"Add new node hwErpsNotifications"
::= { hwDatacomm 256 }
-- Node definitions
--
-- 1.3.6.1.4.1.2011.5.25.256.1
hwErpsObjects OBJECT IDENTIFIER ::= { hwErpsMIB 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.1
hwErpsGlobalResetRapsPktCnt OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
unused(65535)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the RAPS packets counter of all running ERPS ports.
The value is unused(65535) when it is read. And it must be clear(1) when it is set."
::= { hwErpsObjects 1 }
-- ring config table
-- 1.3.6.1.4.1.2011.5.25.256.1.2
hwErpsRingConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsRingConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the configurtion of ERPS rings."
::= { hwErpsObjects 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1
hwErpsRingConfigEntry OBJECT-TYPE
SYNTAX HwErpsRingConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the configurtion of ERPS rings.
The index of the table is ERPS ring id."
INDEX { hwConfigRingId }
::= { hwErpsRingConfigTable 1 }
HwErpsRingConfigEntry ::=
SEQUENCE {
hwConfigRingId
Integer32,
hwConfigRingRowStatus
RowStatus,
hwConfigDescription
DisplayString,
hwConfigControlVlanId
Integer32,
hwConfigProtectedInstanceList
OCTET STRING,
hwConfigWtrTimerSettingValue
Integer32,
hwConfigGuardTimerSettingValue
Integer32,
hwConfigHoldoffTimerSettingValue
Integer32,
hwConfigResetRapsPktCnt
INTEGER,
hwConfigRapsMel
Integer32,
hwConfigVersion
INTEGER,
hwConfigRevertiveMode
INTEGER,
hwConfigRingRole
INTEGER,
hwConfigRapsChannelMode
INTEGER,
hwConfigTcNotifyErpsRing
OCTET STRING,
hwConfigTcProtectionInterval
Integer32,
hwConfigTcProtectionThreshold
Integer32,
hwConfigProtectionSwitch
INTEGER
}
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.1
hwConfigRingId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"ERPS ring Identifier."
::= { hwErpsRingConfigEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.2
hwConfigRingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Operation of CreateAndGo can be used to create a new ERPS ring,
and operation of Destroy be used to destroy an existent ERPS ring."
::= { hwErpsRingConfigEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.3
hwConfigDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual description of the ERPS ring.
It is mandatory that this only contain no more than 80 printable ASCII characters."
::= { hwErpsRingConfigEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.4
hwConfigControlVlanId OBJECT-TYPE
SYNTAX Integer32 (0 | 1..4094)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The control VLAN identifier of the ERPS ring.
If the value of the object is set 0, the operation is to delete configuration."
DEFVAL { 0 }
::= { hwErpsRingConfigEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.5
hwConfigProtectedInstanceList OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..512))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The protected instance list of the ERPS ring."
::= { hwErpsRingConfigEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.6
hwConfigWtrTimerSettingValue OBJECT-TYPE
SYNTAX Integer32 (1..12)
UNITS "minutes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The setting value of the ring's wait to restore timer."
DEFVAL { 5 }
::= { hwErpsRingConfigEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.7
hwConfigGuardTimerSettingValue OBJECT-TYPE
SYNTAX Integer32 (1..200)
UNITS "centiseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The setting value of the ring's guard timer."
::= { hwErpsRingConfigEntry 7 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.8
hwConfigHoldoffTimerSettingValue OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "deciseconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The setting value of the ring's hold-off timer."
DEFVAL { 0 }
::= { hwErpsRingConfigEntry 8 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.9
hwConfigResetRapsPktCnt OBJECT-TYPE
SYNTAX INTEGER
{
clear(1),
unused(65535)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Reset the RAPS packets counter of the ERPS ring's ports.
The value is unused(65535) when it is read. And it must be clear(1) when it is set."
::= { hwErpsRingConfigEntry 9 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.10
hwConfigRapsMel OBJECT-TYPE
SYNTAX Integer32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The MEL is the maintenance entity group(MEG) level providing a communication channel for the ring RAPS information."
DEFVAL { 7 }
::= { hwErpsRingConfigEntry 10 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.11
hwConfigVersion OBJECT-TYPE
SYNTAX INTEGER
{
v1(1),
v2(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set protocol version of the ERPS ring. The default version is v1."
DEFVAL { 1 }
::= { hwErpsRingConfigEntry 11 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.12
hwConfigRevertiveMode OBJECT-TYPE
SYNTAX INTEGER
{
revertive(1),
nonRevertive(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set revertive mode of the ERPS ring. The default mode is revertive."
DEFVAL { 1 }
::= { hwErpsRingConfigEntry 12 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.13
hwConfigRingRole OBJECT-TYPE
SYNTAX INTEGER
{
majorRing(1),
subRing(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specify the ERPS ring as sub-ring."
DEFVAL { 1 }
::= { hwErpsRingConfigEntry 13 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.14
hwConfigRapsChannelMode OBJECT-TYPE
SYNTAX INTEGER
{
virtualChannel(1),
nonVirtualChannel(2),
unused(65535)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set RAPS channel of the sub-ring. By default, non-virtual channel is used.
unused(65535) is displayed when it is read if the ring is major ring."
::= { hwErpsRingConfigEntry 14 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.15
hwConfigTcNotifyErpsRing OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set the list of ERPS rings that will be notified when topology changes."
::= { hwErpsRingConfigEntry 15 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.16
hwConfigTcProtectionInterval OBJECT-TYPE
SYNTAX Integer32 (1..600)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Time interval for topology change protection, in seconds. The default value is 2."
DEFVAL { 2 }
::= { hwErpsRingConfigEntry 16 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.17
hwConfigTcProtectionThreshold OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Threshold of topology change protection. The default value is 3."
DEFVAL { 3 }
::= { hwErpsRingConfigEntry 17 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.18
hwConfigProtectionSwitch OBJECT-TYPE
SYNTAX INTEGER
{
clear(1),
idle(65535)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Cancel current configuration of the ERPS ring. The value is idle(65535) when it is read, and is clear(1) when the current configuration is canceled."
::= { hwErpsRingConfigEntry 18 }
--ring status table
-- 1.3.6.1.4.1.2011.5.25.256.1.3
hwErpsRingStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsRingStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the status of ERPS rings."
::= { hwErpsObjects 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1
hwErpsRingStatusEntry OBJECT-TYPE
SYNTAX HwErpsRingStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the status of ERPS rings.
The index of the table is ERPS ring id."
INDEX { hwConfigRingId }
::= { hwErpsRingStatusTable 1 }
HwErpsRingStatusEntry ::=
SEQUENCE {
hwStatusWtrTimerRunningValue
Integer32,
hwStatusGuardTimerRunningValue
Integer32,
hwStatusHoldoffTimerRunningValue
Integer32,
hwStatusMachineState
INTEGER,
hwStatusTopoLastChangeTime
TimeTicks,
hwStatusWtbTimerRunningValue
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.1
hwStatusWtrTimerRunningValue OBJECT-TYPE
SYNTAX Integer32 (0..720)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The running value of the ring's wait to restore timer."
::= { hwErpsRingStatusEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.2
hwStatusGuardTimerRunningValue OBJECT-TYPE
SYNTAX Integer32 (0..200)
UNITS "centiseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The running value of the ring's guard timer."
::= { hwErpsRingStatusEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.3
hwStatusHoldoffTimerRunningValue OBJECT-TYPE
SYNTAX Integer32 (0..100)
UNITS "deciseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The running value of the ring's hold-off timer."
::= { hwErpsRingStatusEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.4
hwStatusMachineState OBJECT-TYPE
SYNTAX INTEGER
{
idle(1),
protection(2),
manualSwitch(3),
forcedSwitch(4),
pending(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Finite-state machine's state of the ERPS ring.
state value
idle 1
protection 2
manualSwitch 3
forcedSwitch 4
pending 5
"
::= { hwErpsRingStatusEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.5
hwStatusTopoLastChangeTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time since last topology change of the ring."
::= { hwErpsRingStatusEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.2.1.6
hwStatusWtbTimerRunningValue OBJECT-TYPE
SYNTAX Integer32 (0..700)
UNITS "centiseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The running value of the ring's wait to block timer."
::= { hwErpsRingStatusEntry 6 }
--port config table
--1.3.6.1.4.1.2011.5.25.256.1.3
hwErpsPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the configuration of ERPS ports."
::= { hwErpsObjects 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1
hwErpsPortConfigEntry OBJECT-TYPE
SYNTAX HwErpsPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the configuration of ERPS ports.
The index of the table is ERPS ring identifier, port type, port identifier1, port identifier2, port identifier3, port identifier4.
If it is an ethernet port including fast ethernet/gigabit ethernet/eth-trunk, the port type is 1, the port identifier1 is the IfIndex of the ethernet port.
the other port identifier is for extension and not used currently, should be set 0."
INDEX { hwConfigRingId, hwConfigPortType, hwConfigPortId1, hwConfigPortId2, hwConfigPortId3,
hwConfigPortId4 }
::= { hwErpsPortConfigTable 1 }
HwErpsPortConfigEntry ::=
SEQUENCE {
hwConfigPortType
Unsigned32,
hwConfigPortId1
Unsigned32,
hwConfigPortId2
Unsigned32,
hwConfigPortId3
Unsigned32,
hwConfigPortId4
Unsigned32,
hwConfigPortRowStatus
RowStatus,
hwConfigPortConfigRole
Integer32,
hwConfigPortProtectionSwitch
INTEGER
}
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.1
hwConfigPortType OBJECT-TYPE
SYNTAX Unsigned32 (1)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port type.Currently ERPS just supports ethernet port and the value is 1."
::= { hwErpsPortConfigEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.2
hwConfigPortId1 OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port identifier1, when the hwConfigPortType is 1, the value of the object is the IfIndex of the port."
::= { hwErpsPortConfigEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.3
hwConfigPortId2 OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port identifier2, Currently it is not used and only for extension, should be set 0."
::= { hwErpsPortConfigEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.4
hwConfigPortId3 OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port identifier3, Currently it is not used and only for extension, should be set 0."
::= { hwErpsPortConfigEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.5
hwConfigPortId4 OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The port identifier4, Currently it is not used and only for extension, should be set 0."
::= { hwErpsPortConfigEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.6
hwConfigPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Operation of CreateAndGo can be used to have a port join the ERPS ring.
and operation of Destroy be used to have a port leave the ERPS ring."
::= { hwErpsPortConfigEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.7
hwConfigPortConfigRole OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The configued port role:
role value
common 0x10
rplOwner 0x21
rplNeighbour 0x22"
::= { hwErpsPortConfigEntry 7 }
-- 1.3.6.1.4.1.2011.5.25.256.1.4.1.8
hwConfigPortProtectionSwitch OBJECT-TYPE
SYNTAX INTEGER
{
forcedSwitch(1),
manualSwitch(2),
idle(65535)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set the protection switch mode, including forced switch and manual switch. If no mode is set, idle(65535) is displayed."
::= { hwErpsPortConfigEntry 8 }
--port status table
--1.3.6.1.4.1.2011.5.25.256.1.5
hwErpsPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the status of ERPS ports."
::= { hwErpsObjects 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.5.1
hwErpsPortStatusEntry OBJECT-TYPE
SYNTAX HwErpsPortStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the status of ERPS ports.
The index of the table is ERPS ring identifier, port type, port identifier1, port identifier2, port identifier3, port identifier4.
If it is an ethernet port including fast ethernet/gigabit ethernet/eth-trunk, the port type is 1, the port identifier1 is the IfIndex of the ethernet port.
the other port identifier is for extension and not used currently, should be set 0."
INDEX { hwConfigRingId, hwConfigPortType, hwConfigPortId1, hwConfigPortId2, hwConfigPortId3,
hwConfigPortId4 }
::= { hwErpsPortStatusTable 1 }
HwErpsPortStatusEntry ::=
SEQUENCE {
hwPortStatusActiveRole
Integer32,
hwPortStatusSignalStatus
INTEGER,
hwPortStatusFwdStatus
INTEGER
}
-- 1.3.6.1.4.1.2011.5.25.256.1.5.1.1
hwPortStatusActiveRole OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The active port role:
role value
common 0x10
rplOwner 0x21
rplNeighbour 0x22"
::= { hwErpsPortStatusEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.5.1.7
hwPortStatusSignalStatus OBJECT-TYPE
SYNTAX INTEGER
{
failed(1),
nonFailed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The signal status of the port:
state value
failed 1
nonFailed 2"
::= { hwErpsPortStatusEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.5.1.8
hwPortStatusFwdStatus OBJECT-TYPE
SYNTAX INTEGER
{
discarding(1),
forwarding(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The forwarding status of the port:
state value
discarding 1
forwarding 2"
::= { hwErpsPortStatusEntry 3 }
--port Statistics table
--1.3.6.1.4.1.2011.5.25.256.1.6
hwErpsPortStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the statistics of ERPS ports."
::= { hwErpsObjects 6 }
-- 1.3.6.1.4.1.2011.5.25.256.1.6.1
hwErpsPortStatisticsEntry OBJECT-TYPE
SYNTAX HwErpsPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the Statistics of ERPS ports.
The index of the table is ERPS ring identifier, port type, port identifier1, port identifier2, port identifier3, port identifier4.
If it is an ethernet port including fast ethernet/gigabit ethernet/eth-trunk, the port type is 1, the port identifier1 is the IfIndex of the ethernet port.
the other port identifier is for extension and not used currently, should be set 0."
INDEX { hwConfigRingId, hwConfigPortType, hwConfigPortId1, hwConfigPortId2, hwConfigPortId3, hwConfigPortId4}
::= { hwErpsPortStatisticsTable 1 }
HwErpsPortStatisticsEntry ::=
SEQUENCE {
hwRxRapsSfPktCnt
Counter32,
hwTxRapsSfPktCnt
Counter32,
hwRxRapsNrPktCnt
Counter32,
hwTxRapsNrPktCnt
Counter32,
hwRxRapsNrRbPktCnt
Counter32,
hwTxRapsNrRbPktCnt
Counter32,
hwRxRapsFsPktCnt
Counter32,
hwTxRapsFsPktCnt
Counter32,
hwRxRapsMsPktCnt
Counter32,
hwTxRapsMsPktCnt
Counter32,
hwRxRapsEventPktCnt
Counter32,
hwTxRapsEventPktCnt
Counter32
}
-- 1.3.6.1.4.1.2011.5.25.256.1.6.1.1
hwRxRapsSfPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS SF packets."
::= { hwErpsPortStatisticsEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.2
hwTxRapsSfPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS SF packets."
::= { hwErpsPortStatisticsEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.3
hwRxRapsNrPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS NR packets."
::= { hwErpsPortStatisticsEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.4
hwTxRapsNrPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS NR packets."
::= { hwErpsPortStatisticsEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.5
hwRxRapsNrRbPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS NRRB packets."
::= { hwErpsPortStatisticsEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.6
hwTxRapsNrRbPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS NRRB packets."
::= { hwErpsPortStatisticsEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.7
hwRxRapsFsPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS FS packets."
::= { hwErpsPortStatisticsEntry 7 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.8
hwTxRapsFsPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS FS packets."
::= { hwErpsPortStatisticsEntry 8 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.9
hwRxRapsMsPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS MS packets."
::= { hwErpsPortStatisticsEntry 9 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.10
hwTxRapsMsPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS MS packets."
::= { hwErpsPortStatisticsEntry 10 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.11
hwRxRapsEventPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received RAPS Event packets."
::= { hwErpsPortStatisticsEntry 11 }
-- 1.3.6.1.4.1.2011.5.25.256.1.3.1.12
hwTxRapsEventPktCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of transmitted RAPS Event packets."
::= { hwErpsPortStatisticsEntry 12 }
--ERPS port tracking information table
--1.3.6.1.4.1.2011.5.25.256.1.7
hwErpsPortTrackTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwErpsPortTrackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the information of ERPS ports track."
::= { hwErpsObjects 7 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1
hwErpsPortTrackEntry OBJECT-TYPE
SYNTAX HwErpsPortTrackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table includes the information of ERPS ports track.
The index of the table is ERPS ring identifier, port type, port identifier1, port identifier2, port identifier3, port identifier4, protocol type.
If it is an ethernet port including fast ethernet/gigabit ethernet/eth-trunk, the port type is 1, the port identifier1 is the IfIndex of the ethernet port.
the other port identifier is for extension and not used currently, should be set 0."
INDEX { hwConfigRingId, hwConfigPortType, hwConfigPortId1, hwConfigPortId2, hwConfigPortId3, hwConfigPortId4, hwErpsPortTrackProtocolType}
::= { hwErpsPortTrackTable 1 }
HwErpsPortTrackEntry ::=
SEQUENCE {
hwErpsPortTrackProtocolType
INTEGER,
hwErpsPortTrackRowStatus
RowStatus,
hwErpsPortTrackCfmMdName
OCTET STRING,
hwErpsPortTrackCfmMaName
OCTET STRING,
hwErpsPortTrackCfmMepId
Integer32,
hwErpsPortTrackCfmRmepId
Integer32
}
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.1
hwErpsPortTrackProtocolType OBJECT-TYPE
SYNTAX INTEGER
{
cfm(1)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The protocol type that ERPS port tracks. Currently ERPS port just supports tracking CFM."
::= { hwErpsPortTrackEntry 1 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.2
hwErpsPortTrackRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The CreateAndGo operation enables an ERPS port to track the protocol. The Destroy operation disables an ERPS port from tracking the protocol."
::= { hwErpsPortTrackEntry 2 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.3
hwErpsPortTrackCfmMdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..43))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of maintenance domain."
::= { hwErpsPortTrackEntry 3 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.4
hwErpsPortTrackCfmMaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..43))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of maintenance association."
::= { hwErpsPortTrackEntry 4 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.5
hwErpsPortTrackCfmMepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"MEP ID."
::= { hwErpsPortTrackEntry 5 }
-- 1.3.6.1.4.1.2011.5.25.256.1.7.1.6
hwErpsPortTrackCfmRmepId OBJECT-TYPE
SYNTAX Integer32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Remote MEP ID."
::= { hwErpsPortTrackEntry 6 }
-- 1.3.6.1.4.1.2011.5.25.256.4
hwErpsNotifications OBJECT IDENTIFIER ::= { hwErpsMIB 4 }
-- 1.3.6.1.4.1.2011.5.25.256.4.1
hwErpsFwStateForwarding NOTIFICATION-TYPE
OBJECTS { hwConfigRingId , ifName }
STATUS current
DESCRIPTION
"Trap message is generated by ERPS node when
it detects that the state of ERPS port changes to forwarding."
::= { hwErpsNotifications 1 }
-- 1.3.6.1.4.1.2011.5.25.256.4.2
hwErpsFwStateDiscarding NOTIFICATION-TYPE
OBJECTS { hwConfigRingId , ifName }
STATUS current
DESCRIPTION
"Trap message is generated by ERPS node when
it detects that the state of ERPS port changes to discarding."
::= { hwErpsNotifications 2 }
-- 1.3.6.1.4.1.2011.5.25.256.2
hwErpsGroups OBJECT IDENTIFIER ::= { hwErpsMIB 2 }
-- 1.3.6.1.4.1.2011.5.25.256.2.1
hwErpsGlobalInfoGroup OBJECT-GROUP
OBJECTS { hwErpsGlobalResetRapsPktCnt }
STATUS current
DESCRIPTION
"The group of global information."
::= { hwErpsGroups 1 }
-- 1.3.6.1.4.1.2011.5.25.256.2.2
hwErpsRingConfigInfoGroup OBJECT-GROUP
OBJECTS { hwConfigRingRowStatus, hwConfigDescription, hwConfigControlVlanId, hwConfigProtectedInstanceList,
hwConfigWtrTimerSettingValue, hwConfigGuardTimerSettingValue, hwConfigHoldoffTimerSettingValue,
hwConfigResetRapsPktCnt, hwConfigRapsMel, hwConfigVersion, hwConfigRevertiveMode, hwConfigRingRole, hwConfigRapsChannelMode, hwConfigTcNotifyErpsRing,
hwConfigTcProtectionInterval, hwConfigTcProtectionThreshold, hwConfigProtectionSwitch }
STATUS current
DESCRIPTION
"The group of ring configuration."
::= { hwErpsGroups 2 }
-- 1.3.6.1.4.1.2011.5.25.256.2.3
hwErpsRingStatusInfoGroup OBJECT-GROUP
OBJECTS { hwStatusWtrTimerRunningValue, hwStatusGuardTimerRunningValue, hwStatusHoldoffTimerRunningValue,
hwStatusMachineState, hwStatusTopoLastChangeTime, hwStatusWtbTimerRunningValue }
STATUS current
DESCRIPTION
"The group of ring status."
::= { hwErpsGroups 3 }
-- 1.3.6.1.4.1.2011.5.25.256.2.4
hwErpsPortConfigInfoGroup OBJECT-GROUP
OBJECTS { hwConfigPortRowStatus, hwConfigPortConfigRole, hwConfigPortProtectionSwitch }
STATUS current
DESCRIPTION
"The group of port configuration."
::= { hwErpsGroups 4 }
-- 1.3.6.1.4.1.2011.5.25.256.2.5
hwErpsPortStatusInfoGroup OBJECT-GROUP
OBJECTS { hwPortStatusActiveRole, hwPortStatusSignalStatus, hwPortStatusFwdStatus }
STATUS current
DESCRIPTION
"The group of port status."
::= { hwErpsGroups 5 }
-- 1.3.6.1.4.1.2011.5.25.256.2.6
hwErpsPortStatisticsInfoGroup OBJECT-GROUP
OBJECTS { hwRxRapsSfPktCnt, hwTxRapsSfPktCnt, hwRxRapsNrPktCnt, hwTxRapsNrPktCnt,
hwRxRapsNrRbPktCnt, hwTxRapsNrRbPktCnt, hwRxRapsFsPktCnt, hwTxRapsFsPktCnt, hwRxRapsMsPktCnt, hwTxRapsMsPktCnt, hwRxRapsEventPktCnt, hwTxRapsEventPktCnt }
STATUS current
DESCRIPTION
"The group of port information."
::= { hwErpsGroups 6 }
-- 1.3.6.1.4.1.2011.5.25.256.2.7
hwErpsPortTrackInfoGroup OBJECT-GROUP
OBJECTS { hwErpsPortTrackProtocolType, hwErpsPortTrackRowStatus, hwErpsPortTrackCfmMdName, hwErpsPortTrackCfmMaName, hwErpsPortTrackCfmMepId, hwErpsPortTrackCfmRmepId }
STATUS current
DESCRIPTION
"The group of ERPS port tracking information."
::= { hwErpsGroups 7 }
-- 1.3.6.1.4.1.2011.5.25.256.2.8
hwErpsNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { hwErpsFwStateForwarding, hwErpsFwStateDiscarding }
STATUS current
DESCRIPTION
"The notification group."
::= { hwErpsGroups 8 }
-- compliance statements
hwErpsConformance OBJECT IDENTIFIER ::= { hwErpsMIB 3 }
hwErpsCompliances OBJECT IDENTIFIER ::= { hwErpsConformance 1 }
hwErpsCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The core compliance statement for all implementations."
MODULE -- this module
MANDATORY-GROUPS {
hwErpsGlobalInfoGroup,
hwErpsRingConfigInfoGroup,
hwErpsRingStatusInfoGroup,
hwErpsPortConfigInfoGroup,
hwErpsPortStatusInfoGroup,
hwErpsPortStatisticsInfoGroup,
hwErpsNotificationGroup
}
::= { hwErpsCompliances 1 }
END
--
-- HUAWEI-ERPS-MIBv2.my
--