-- Copyright (C) 2017 by HUAWEI TECHNOLOGIES. All rights reserved
|
|
--
|
|
-- Description:HUAWEI ERRORDOWN MIB
|
|
-- Reference:
|
|
-- Version: V2.01
|
|
-- History:
|
|
-- V1.00 W55319, 2011-08-08, publish
|
|
-- ===========================================================
|
|
|
|
HUAWEI-ERRORDOWN-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
EnabledStatus
|
|
FROM P-BRIDGE-MIB
|
|
ifIndex, ifName
|
|
FROM IF-MIB
|
|
DisplayString, RowStatus
|
|
FROM SNMPv2-TC
|
|
Integer32, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
--
|
|
-- Module Identifier
|
|
--
|
|
hwErrordownMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201108081000Z" -- Aug 8, 2011 at 10:00 GMT
|
|
ORGANIZATION
|
|
"Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"The HUAWEI-ERRORDOWN-MIB contains objects to
|
|
Manage configuration and Monitor running state
|
|
for ERROR-DOWN feature."
|
|
REVISION "201108081000Z" -- Aug 8, 2011 at 10:00 GMT
|
|
DESCRIPTION
|
|
"The initial revision of this MIB module."
|
|
::= { hwDatacomm 257 }
|
|
--
|
|
-- Objects Identifier
|
|
--
|
|
hwErrordownObjects OBJECT IDENTIFIER ::= { hwErrordownMIB 1 }
|
|
hwErrordownNotifications OBJECT IDENTIFIER ::= { hwErrordownMIB 2 }
|
|
hwErrordownConformance OBJECT IDENTIFIER ::= { hwErrordownMIB 3 }
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
hwErrordownCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cause of error-down."
|
|
::= { hwErrordownObjects 1 }
|
|
|
|
hwErrordownRecoverType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of error-down recovery."
|
|
::= { hwErrordownObjects 2 }
|
|
|
|
--
|
|
-- Notification Identifier
|
|
--
|
|
hwErrordown NOTIFICATION-TYPE
|
|
OBJECTS { ifName, hwErrordownCause }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event is reported when error-down occur."
|
|
::= { hwErrordownNotifications 1 }
|
|
|
|
hwErrordownRecovery NOTIFICATION-TYPE
|
|
OBJECTS { ifName, hwErrordownCause, hwErrordownRecoverType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event is reported when error-down recover."
|
|
::= { hwErrordownNotifications 2 }
|
|
|
|
--
|
|
-- Conformance Identifier
|
|
--
|
|
hwErrordownCompliances OBJECT IDENTIFIER ::= { hwErrordownConformance 1 }
|
|
|
|
hwErrordowFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Error-down compliance."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hwErrordownObjectGroup, hwErrordownNotificationGroup }
|
|
::= { hwErrordownCompliances 1 }
|
|
|
|
hwErrordownGroups OBJECT IDENTIFIER ::= { hwErrordownConformance 2 }
|
|
|
|
hwErrordownObjectGroup OBJECT-GROUP
|
|
OBJECTS { hwErrordownCause, hwErrordownRecoverType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Error-down object group."
|
|
::= { hwErrordownGroups 1 }
|
|
|
|
hwErrordownNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { hwErrordown, hwErrordownRecovery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Error-down notification group."
|
|
::= { hwErrordownGroups 2 }
|
|
|
|
END
|