129 lines
4.8 KiB
Plaintext
129 lines
4.8 KiB
Plaintext
-- =================================================================
|
|
-- Copyright (C) 2009 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: HUAWEI SYS CLOCK MIB
|
|
-- Reference: huawei enterprise mib
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- initial version 2009-07-25
|
|
-- =================================================================
|
|
|
|
HUAWEI-SYS-CLOCK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hwDatacomm
|
|
FROM HUAWEI-MIB
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TimeTicks, Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TimeStamp, TruthValue, RowStatus, TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
hwSysClockMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200907250000Z" -- July 25, 2009 at 00:00 GMT
|
|
ORGANIZATION
|
|
"Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"HUAWEI-SYS-CLOCK-MIB is used to configure and query time information,
|
|
such as the system time, time zone, and daylight saving time.
|
|
Root object: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).
|
|
huawei(2011).huaweiMgmt(5).hwDatacomm(25).hwSysClockMIB(205) "
|
|
REVISION "200907250000Z" -- July 25, 2009 at 00:00 GMT
|
|
DESCRIPTION
|
|
"The initial revision of this MIB module ."
|
|
::= { hwDatacomm 205 }
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- Huawei SYS Clock set mib object
|
|
|
|
huaweiClockObjects OBJECT IDENTIFIER ::= { hwSysClockMIB 1 }
|
|
|
|
hwLocalClock OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set and query the local time that is in the format of
|
|
'YYYY-MM-DD,HH:MM:SS'. "
|
|
::= { huaweiClockObjects 1 }
|
|
|
|
hwUTCClock OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to configure and query the system UTC time that is in the
|
|
format of 'YYYY-MM-DD,HH:MM:SS'. "
|
|
::= { huaweiClockObjects 2 }
|
|
|
|
-- -------------------------------------------------------------
|
|
-- HUAWEI-SYS-CLOCK-MIB MIB - Notification Information
|
|
-- -------------------------------------------------------------
|
|
|
|
huaweiClockNotifications OBJECT IDENTIFIER ::= { hwSysClockMIB 2 }
|
|
|
|
hwClockChanged NOTIFICATION-TYPE
|
|
OBJECTS { hwUTCClock }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the alarm reported when the system time changes.
|
|
In addition, the new system time is recorded."
|
|
::= { huaweiClockNotifications 1 }
|
|
|
|
-- -------------------------------------------------------------
|
|
-- HUAWEI-SYS-CLOCK-MIB MIB - Conformance Information
|
|
-- -------------------------------------------------------------
|
|
|
|
huaweiClockMIBConformance OBJECT IDENTIFIER ::= { hwSysClockMIB 3 }
|
|
|
|
hwClockMIBCompliances OBJECT IDENTIFIER ::= { huaweiClockMIBConformance 1 }
|
|
|
|
hwClockMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The compliance statement for
|
|
entities that support the huawei Clock MIB.
|
|
"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { hwClockSetGroup, hwClockNotificationGroup }
|
|
::= { hwClockMIBCompliances 1 }
|
|
|
|
huaweiClockMIBGroups OBJECT IDENTIFIER ::= { huaweiClockMIBConformance 2 }
|
|
|
|
hwClockSetGroup OBJECT-GROUP
|
|
OBJECTS { hwLocalClock, hwUTCClock }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects on Clock setting level information.
|
|
"
|
|
::= { huaweiClockMIBGroups 1 }
|
|
|
|
hwClockNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { hwClockChanged }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of notifications in the module"
|
|
::= { huaweiClockMIBGroups 2 }
|
|
|
|
|
|
END
|
|
|
|
--
|
|