292 lines
8.7 KiB
Plaintext
292 lines
8.7 KiB
Plaintext
-- MIB created 10/11/99 20:28:35, by
|
|
-- SMIC (the next generation) version 1.6.29, November 22, 1994.
|
|
|
|
IBM-INTERFACE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- From file: "ibminterface.mi2"
|
|
-- Compile options "G A T M"
|
|
|
|
IMPORTS
|
|
Counter32, IpAddress
|
|
FROM SNMPv2-SMI-v1
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM SNMPv2-TC-v1
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
ifIndex
|
|
FROM RFC1213-MIB;
|
|
|
|
ibmIROCroutinginterface OBJECT IDENTIFIER ::= { enterprises ibm(2) ibmProd(6) ibmIROC(119) ibmIROCrouting(4) 17 }
|
|
-- MODULE-IDENTITY
|
|
-- LastUpdated
|
|
-- 9902171200Z
|
|
-- OrgName
|
|
-- IBM
|
|
-- ContactInfo
|
|
-- Randy Worzella
|
|
-- IBM Corporation
|
|
-- 800 Park Offices Drive
|
|
-- FBWA/664
|
|
-- P.O. Box 12195
|
|
-- Research Triangle Park, NC 27709, USA
|
|
-- Tel: 1 919 254 2202
|
|
-- E-mail: worzella@us.ibm.com
|
|
-- Descr
|
|
-- This MIB module contains enterprise specific definitions for
|
|
-- generic interface management.
|
|
|
|
ibminterfaceClearTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IbminterfaceClearEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table allowing interface counters to be cleared."
|
|
::= { ibmIROCroutinginterface 1 }
|
|
|
|
ibminterfaceClearEntry OBJECT-TYPE
|
|
SYNTAX IbminterfaceClearEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entry identifying a particular interface whose counters
|
|
are to be cleared."
|
|
INDEX { ifIndex }
|
|
::= { ibminterfaceClearTable 1 }
|
|
|
|
IbminterfaceClearEntry ::= SEQUENCE {
|
|
ibminterfaceClearInOctets INTEGER,
|
|
ibminterfaceClearInUcastPkts INTEGER,
|
|
ibminterfaceClearInMulticastPkts INTEGER,
|
|
ibminterfaceClearInErrors INTEGER,
|
|
ibminterfaceClearInAll INTEGER,
|
|
ibminterfaceClearOutOctets INTEGER,
|
|
ibminterfaceClearOutUcastPkts INTEGER,
|
|
ibminterfaceClearOutMulticastPkts INTEGER,
|
|
ibminterfaceClearOutErrors INTEGER,
|
|
ibminterfaceClearOutAll INTEGER,
|
|
ibminterfaceClearMaintTest INTEGER,
|
|
ibminterfaceClearDeviceSpecific INTEGER,
|
|
ibminterfaceClearAll INTEGER
|
|
}
|
|
|
|
ibminterfaceClearInOctets OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of bytes
|
|
received over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 1 }
|
|
|
|
ibminterfaceClearInUcastPkts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of unicast
|
|
packets received over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 2 }
|
|
|
|
ibminterfaceClearInMulticastPkts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of multicast
|
|
packets received over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 3 }
|
|
|
|
ibminterfaceClearInErrors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counters for all
|
|
types of input errors are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 4 }
|
|
|
|
ibminterfaceClearInAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counters for all
|
|
input counters (byte, packet, error) are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 5 }
|
|
|
|
ibminterfaceClearOutOctets OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of bytes
|
|
sent over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 6 }
|
|
|
|
ibminterfaceClearOutUcastPkts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of unicast
|
|
packets sent over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 7 }
|
|
|
|
ibminterfaceClearOutMulticastPkts OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counter of multicast
|
|
packets sent over this interface is reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 8 }
|
|
|
|
ibminterfaceClearOutErrors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counters for all
|
|
types of output errors are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 9 }
|
|
|
|
ibminterfaceClearOutAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counters for all
|
|
output counters (byte, packet, error) are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 10 }
|
|
|
|
ibminterfaceClearMaintTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), the counters for
|
|
self test pass, self test fail and maintenance
|
|
fail are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 11 }
|
|
|
|
ibminterfaceClearDeviceSpecific OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), all the device specific
|
|
counters are reset. For example, for an Ethernet
|
|
interface, all the counters provided in the
|
|
dot3StatsTable are reset.
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 12 }
|
|
|
|
ibminterfaceClearAll OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noaction(0),
|
|
clear(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When SET to a value of clear(1), all the reset actions
|
|
performed by the MIB objects defined above are executed
|
|
at once.
|
|
|
|
This action has the same behavior as executing the
|
|
CLEAR command from the T5 console prompt (+).
|
|
|
|
When READ, this object always returns a value of noaction(0),
|
|
since this object is intended as a trigger, rather than
|
|
providing information."
|
|
::= { ibminterfaceClearEntry 13 }
|
|
|
|
|
|
END
|
|
|