484 lines
13 KiB
Plaintext
484 lines
13 KiB
Plaintext
IGNITENET-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Counter64, IpAddress,
|
|
enterprises FROM SNMPv2-SMI
|
|
DisplayString, TruthValue, MacAddress FROM SNMPv2-TC
|
|
OBJECT-GROUP FROM SNMPv2-CONF;
|
|
|
|
ignitenetMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201602240000Z"
|
|
ORGANIZATION "IgniteNet"
|
|
CONTACT-INFO "support@ignitenet.com"
|
|
DESCRIPTION "The MIB module for IgniteNet entities"
|
|
REVISION "201602240000Z"
|
|
DESCRIPTION "Initial revision"
|
|
::= { ignitenet 1 }
|
|
|
|
ignitenet OBJECT IDENTIFIER ::= { enterprises 47307 }
|
|
|
|
product OBJECT IDENTIFIER ::= { ignitenetMIB 1 }
|
|
ethernetPorts OBJECT IDENTIFIER ::= { ignitenetMIB 2 }
|
|
radios OBJECT IDENTIFIER ::= { ignitenetMIB 3 }
|
|
metrolinqRadios OBJECT IDENTIFIER ::= { ignitenetMIB 4 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- IgniteNet product descriptions
|
|
-- ===========================================================
|
|
|
|
model OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model of the IgniteNet product"
|
|
::= { product 1 }
|
|
|
|
hwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware version of the IgniteNet product"
|
|
::= { product 2 }
|
|
|
|
|
|
fwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version of the IgniteNet product"
|
|
::= { product 3 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- IgniteNet ethernet ports info descriptions
|
|
-- ===========================================================
|
|
|
|
ethNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ethernet ports (regardless of their
|
|
current state) present on this system."
|
|
::= { ethernetPorts 1 }
|
|
|
|
|
|
-- Ethernet Info Table
|
|
|
|
ethInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of ethernet ports. The number of entries is
|
|
given by the value of ethNumber."
|
|
::= { ethernetPorts 2 }
|
|
|
|
ethInfoEntry OBJECT-TYPE
|
|
SYNTAX EthInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing ethernet port status information."
|
|
INDEX { ethNumber }
|
|
::= { ethInfoTable 1 }
|
|
|
|
EthInfoEntry ::=
|
|
SEQUENCE {
|
|
ethInfoIndex EthernetIndex,
|
|
ethDescr DisplayString,
|
|
ethInfoSpeed Integer32,
|
|
ethInfoDuplex INTEGER
|
|
}
|
|
|
|
ethInfoIndex OBJECT-TYPE
|
|
SYNTAX EthernetIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each radio, starting from one."
|
|
::= { ethInfoEntry 1 }
|
|
|
|
ethDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet speed in MB/s"
|
|
::= { ethInfoEntry 2 }
|
|
|
|
ethInfoSpeed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet speed in MB/s"
|
|
::= { ethInfoEntry 3 }
|
|
|
|
ethInfoDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
half(1),
|
|
full(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet speed in MB/s"
|
|
::= { ethInfoEntry 4 }
|
|
|
|
|
|
|
|
-- ===========================================================
|
|
-- IgniteNet MetroLinq radio info descriptions
|
|
-- ===========================================================
|
|
|
|
mlRadioNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of radios (regardless of their
|
|
current state) present on this system."
|
|
::= { metrolinqRadios 1 }
|
|
|
|
-- Radio info table
|
|
|
|
mlRadioInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MlRadioInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of radio entries. The number of entries is
|
|
given by the value of radioNumber."
|
|
::= { metrolinqRadios 2 }
|
|
|
|
mlRadioInfoEntry OBJECT-TYPE
|
|
SYNTAX MlRadioInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular interface."
|
|
INDEX { mlRadioNumber }
|
|
::= { mlRadioInfoTable 1 }
|
|
|
|
MlRadioInfoEntry ::=
|
|
SEQUENCE {
|
|
mlRadioInfoIndex RadioIndex,
|
|
mlRadioInfoEnabled INTEGER,
|
|
mlRadioInfoRegDomain DisplayString,
|
|
mlRadioInfoFrequency FrequencyGHz,
|
|
mlRadioInfomcs RadioMcsRate,
|
|
mlRadioInfoAckTimeout Integer32,
|
|
mlRadioInfoTxPower Integer32,
|
|
mlRadioInfoAMSDU INTEGER,
|
|
mlRadioInfoAMPDU INTEGER,
|
|
mlRadioInfoRSSILocal Integer32,
|
|
mlRadioInfoRSSIRemote Integer32,
|
|
mlRadioInfoEncryption INTEGER,
|
|
mlRadioInfoSSID DisplayString,
|
|
mlRadioInfoFailover INTEGER
|
|
}
|
|
|
|
mlRadioInfoIndex OBJECT-TYPE
|
|
SYNTAX RadioIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each radio, starting from one."
|
|
::= { mlRadioInfoEntry 1 }
|
|
|
|
mlRadioInfoEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1) -- ready to pass packets
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The enabled or disabled state of the radio."
|
|
::= { mlRadioInfoEntry 2 }
|
|
|
|
mlRadioInfoRegDomain OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regulation domain set for the radio."
|
|
::= { mlRadioInfoEntry 3 }
|
|
|
|
mlRadioInfoFrequency OBJECT-TYPE
|
|
SYNTAX FrequencyGHz
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency, raw value expressed in MHz, displayed in GHz"
|
|
::= { mlRadioInfoEntry 4 }
|
|
|
|
mlRadioInfomcs OBJECT-TYPE
|
|
SYNTAX RadioMcsRate
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value of the radio Modulation and Coding Scheme"
|
|
::= { mlRadioInfoEntry 5 }
|
|
|
|
mlRadioInfoAckTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio ack timeout in µs"
|
|
::= { mlRadioInfoEntry 6 }
|
|
|
|
mlRadioInfoTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio transmission power in dBm"
|
|
::= { mlRadioInfoEntry 7 }
|
|
|
|
mlRadioInfoAMSDU OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio frame aggregation with MAC Service Data Unit"
|
|
::= { mlRadioInfoEntry 8 }
|
|
|
|
mlRadioInfoAMPDU OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio frame aggregation with MAC Protocol Data Unit"
|
|
::= { mlRadioInfoEntry 9 }
|
|
|
|
mlRadioInfoRSSILocal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio received signal strength indicator of the local site"
|
|
::= { mlRadioInfoEntry 10 }
|
|
|
|
mlRadioInfoRSSIRemote OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Radio received signal strength indicator of the remote site"
|
|
::= { mlRadioInfoEntry 11 }
|
|
|
|
mlRadioInfoEncryption OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Encryption use on the radio"
|
|
::= { mlRadioInfoEntry 12 }
|
|
|
|
mlRadioInfoSSID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting to failover to 5 GHz radio if 60 GHz is not available or out of range."
|
|
::= { mlRadioInfoEntry 13 }
|
|
|
|
|
|
mlRadioInfoFailover OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting to failover to 5 GHz radio if 60 GHz is not available or out of range."
|
|
::= { mlRadioInfoEntry 14 }
|
|
|
|
-- Radio Status table
|
|
|
|
mlRadioStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MlRadioStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of radio entries. The number of entries is
|
|
given by the value of radioNumber."
|
|
::= { metrolinqRadios 3 }
|
|
|
|
mlRadioStatusEntry OBJECT-TYPE
|
|
SYNTAX MlRadioStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing radio status information."
|
|
INDEX { mlRadioNumber }
|
|
::= { mlRadioStatusTable 1 }
|
|
|
|
MlRadioStatusEntry ::=
|
|
SEQUENCE {
|
|
mlRadioStatusIndex RadioIndex,
|
|
mlRadioStatusFailoverStatus INTEGER,
|
|
mlRadioStatusFailoverStats Integer32,
|
|
mlRadioStatusCRCErrors Integer32,
|
|
mlRadioStatusDrops Integer32,
|
|
mlRadioStatusRetries Integer32
|
|
}
|
|
|
|
mlRadioStatusIndex OBJECT-TYPE
|
|
SYNTAX RadioIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater or equal to zero, for each radio, starting from zero."
|
|
::= { mlRadioStatusEntry 1 }
|
|
|
|
mlRadioStatusFailoverStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indication whether or not 60 GHz radio is failovered to 5 GHz radio."
|
|
::= { mlRadioStatusEntry 2 }
|
|
|
|
mlRadioStatusFailoverStats OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of radio failovers."
|
|
::= { mlRadioStatusEntry 3 }
|
|
|
|
mlRadioStatusCRCErrors OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of CRC errors."
|
|
::= { mlRadioStatusEntry 4 }
|
|
|
|
mlRadioStatusDrops OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of radio packet drops."
|
|
::= { mlRadioStatusEntry 5 }
|
|
|
|
|
|
mlRadioStatusRetries OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of radio retries."
|
|
::= { mlRadioStatusEntry 6 }
|
|
|
|
-- ===========================================================
|
|
-- Textual Conventions
|
|
-- ===========================================================
|
|
|
|
RadioIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each radio, starting from one."
|
|
SYNTAX Integer32 (1..2147483647)
|
|
|
|
EthernetIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each ethernet port, starting from one."
|
|
SYNTAX Integer32 (1..2147483647)
|
|
|
|
EthernetIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater or equal to zero, for each radio, starting from zero."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
FrequencyGHz ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-3"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency, raw value expressed in MHz, displayed in GHz"
|
|
SYNTAX Integer32 (0..100000000)
|
|
|
|
RadioMcsRate ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value of the radio Modulation and Coding Scheme"
|
|
SYNTAX INTEGER {
|
|
auto(0),
|
|
mcs-6m(4),
|
|
mcs-9M(5),
|
|
mcs-12M(6),
|
|
mcs-18M(7),
|
|
mcs-24M(8),
|
|
mcs-36M(9),
|
|
mcs-48M(10),
|
|
mcs-54M(11),
|
|
mcs0(12),
|
|
mcs1(13),
|
|
mcs2(14),
|
|
mcs3(15),
|
|
mcs4(16),
|
|
mcs5(17),
|
|
mcs6(18),
|
|
mcs7(19),
|
|
mcs8(20),
|
|
mcs9(21),
|
|
mcs10(22),
|
|
mcs11(23),
|
|
mcs12(24),
|
|
mcs13(25),
|
|
mcs14(26),
|
|
mcs15(27),
|
|
nss1-mcs0(30),
|
|
nss1-mcs1(31),
|
|
nss1-mcs2(32),
|
|
nss1-mcs3(33),
|
|
nss1-mcs4(34),
|
|
nss1-mcs5(35),
|
|
nss1-mcs6(36),
|
|
nss1-mcs7(37),
|
|
nss1-mcs8(38),
|
|
nss1-mcs9(39),
|
|
nss2-mcs1(40),
|
|
nss2-mcs2(41),
|
|
nss2-mcs3(42),
|
|
nss2-mcs4(43),
|
|
nss2-mcs5(44),
|
|
nss2-mcs6(45),
|
|
nss2-mcs7(46),
|
|
nss2-mcs8(47),
|
|
nss2-mcs9(49)
|
|
}
|
|
|
|
END
|
|
|
|
|