-- Juniper Enterprise Specific MIB: Interface MIB Extension
--
-- Copyright (c) 1999-2012, Juniper Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
JUNIPER-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Gauge32, Integer32, Counter64, Counter32, Unsigned32, TimeTicks
FROM SNMPv2-SMI
CounterBasedGauge64
FROM HCNUM-TC
ifEntry,ifIndex
FROM IF-MIB
TimeStamp, TruthValue
FROM SNMPv2-TC
jnxMibs
FROM JUNIPER-SMI;
ifJnx MODULE-IDENTITY
LAST-UPDATED "201109221523Z" -- Thu Sept 22 15:23:51 2011 UTC
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Technical Assistance Center
Juniper Networks, Inc.
1133 Innovation Way
Sunnyvale, CA 94089
E-mail: support@juniper.net"
DESCRIPTION
"The MIB modules extends the ifTable as
defined in IF-MIB."
REVISION "201105100000Z" -- 10 May, 2011
DESCRIPTION
"New Layer2 Policer Counters Added to ifJnxTable for MX Series only"
REVISION "201109220000Z"
DESCRIPTION
"Added new OIDs Crc and Fcs Erros.
Added new Trap ifJnxErrors"
REVISION "200706050000Z" -- 05 June, 2007
DESCRIPTION
"New Time Domain Reflectometery Added"
REVISION "200210310000Z" -- 31 Oct, 2002
DESCRIPTION
"New error counters added to ifJnxTable"
REVISION "200106210000Z" -- 21 June, 2001
DESCRIPTION
"New objects ifHCIn1SecRate and
ifHCOut1SecRate added"
REVISION "200103150000Z" -- 15 March, 2001
DESCRIPTION
"New objects ifHCIn1SecOctets and
ifHCOut1SecOctets added"
REVISION "201510150000Z" -- 14 Oct, 2015
DESCRIPTION
"Initial Version"
REVISION "201510150000Z" -- 16 April, 2018
DESCRIPTION
"Adding table for ifJnxMediaTable"
REVISION "202001010000Z" -- 01 Jan, 2020
DESCRIPTION
"New object ifJnxInputErrors added"
::= { jnxMibs 3 }
--
-- This table augments ifTable
--
ifJnxTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJnxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table."
::= { ifJnx 1 }
ifJnxEntry OBJECT-TYPE
SYNTAX IfJnxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
AUGMENTS { ifEntry }
::= { ifJnxTable 1 }
IfJnxEntry ::=
SEQUENCE {
ifIn1SecRate Gauge32,
ifIn1SecOctets Gauge32,
ifIn1SecPkts Gauge32,
ifOut1SecRate Gauge32,
ifOut1SecOctets Gauge32,
ifOut1SecPkts Gauge32,
ifHCIn1SecRate CounterBasedGauge64,
ifHCOut1SecRate CounterBasedGauge64,
ifJnxInErrors Counter64,
ifJnxInFrameErrors Counter64,
ifJnxInQDrops Counter64,
ifJnxInRunts Counter64,
ifJnxInGiants Counter64,
ifJnxInDiscards Counter64,
ifJnxInHslCrcErrors Counter64,
ifJnxInHslFifoOverFlows Counter64,
ifJnxInL3Incompletes Counter64,
ifJnxInL2ChanErrors Counter64,
ifJnxInL2MismatchTimeouts Counter64,
ifJnxInInvalidVCs Counter64,
ifJnxInFifoErrors Counter32,
ifJnxBucketDrops Counter64,
ifJnxSramErrors Counter32,
ifJnxOutErrors Counter64,
ifJnxCollisions Counter64,
ifJnxCarrierTrans Counter64,
ifJnxOutQDrops Counter64,
ifJnxOutAgedErrors Counter64,
ifJnxOutFifoErrors Counter32,
ifJnxOutHslFifoUnderFlows Counter64,
ifJnxOutHslCrcErrors Counter32,
ifJnxCrcErrors Counter64,
ifJnxFcsErrors Counter64,
ifHCIn1SecOctets CounterBasedGauge64,
ifHCOut1SecOctets CounterBasedGauge64,
ifJnxInputErrors Counter64
}
ifIn1SecRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next higher (sub-)layer."
::= { ifJnxEntry 1 }
ifIn1SecOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets per second (Bps, Bytes per
second), delivered by this (sub-)layer to its next
higher (sub-)layer."
::= { ifJnxEntry 2 }
ifIn1SecPkts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second (pps), delivered
by this (sub-)layer to its next higher (sub-)layer."
::= { ifJnxEntry 3 }
ifOut1SecRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next lower (sub-)layer."
::= { ifJnxEntry 4 }
ifOut1SecOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets per second (Bps, Bytes per
second), delivered by this (sub-)layer to its next
lower (sub-)layer."
::= { ifJnxEntry 5 }
ifOut1SecPkts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second (pps), delivered
by this (sub-)layer to its next lower (sub-)layer."
::= { ifJnxEntry 6 }
ifHCIn1SecRate OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next higher (sub-)layer.
This object is a 64 bit version of ifIn1SecRate."
::= { ifJnxEntry 7 }
ifHCOut1SecRate OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next lower (sub-)layer.
This object is a 64 bit version of ifOut1SecRate."
::= { ifJnxEntry 8 }
ifJnxInErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errors: The sum of the incoming frame aborts and FCS errors."
::= { ifJnxEntry 9 }
ifJnxInFrameErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Framing Errors: The number of input packets which were
misaligned."
::= { ifJnxEntry 10 }
ifJnxInQDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Drops: The number of packets dropped by the input queue of
the I/O Manager ASIC."
::= { ifJnxEntry 11 }
ifJnxInRunts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Runts: Frames received that are smaller than the runt
threshold."
::= { ifJnxEntry 12 }
ifJnxInGiants OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Giants: Frames received that are larger than the giant
threshold."
::= { ifJnxEntry 13 }
ifJnxInDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Policed Discards: Frames that the incoming packet match code
discarded because they were not recognized or of interest."
::= { ifJnxEntry 14 }
ifJnxInHslCrcErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS Link CRC Errors: The number of CRC errors on the
high-speed links between the ASICs responsible for handling
the router interfaces while receiving packets."
::= { ifJnxEntry 15 }
ifJnxInHslFifoOverFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS link FIFO overflows: The number of FIFO overflows on the
high-speed links between the ASICs responsible for handling
the router interfaces."
::= { ifJnxEntry 16 }
ifJnxInL3Incompletes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L3 incompletes: The number of incoming packets that fail
Layer 3 sanity checks of the header."
::= { ifJnxEntry 17 }
ifJnxInL2ChanErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L2 channel errors: the number of incoming packets for which
the sofware could not find a valid logical interface."
::= { ifJnxEntry 18 }
ifJnxInL2MismatchTimeouts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L2 mismatch timeouts: The count of malformed or short packets
that cause the incoming packet handler to discard the frame
as unreadable."
::= { ifJnxEntry 19 }
ifJnxInInvalidVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Invalid VCs: Number of cells that arrived for a nonexistent
virtual circuit."
::= { ifJnxEntry 20 }
ifJnxInFifoErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FIFO errors: The number of FIFO errors in the receive
direction as reported by the ASIC on the PIC."
::= { ifJnxEntry 21 }
ifJnxBucketDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bucket drops: Drops due to traffic load exceeding the
interface transmit/receive leaky bucket configuration."
::= { ifJnxEntry 22 }
ifJnxSramErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SRAM errors: This counter increments when a hardware error
has occurred in the SRAM on the PIC."
::= { ifJnxEntry 23 }
ifJnxOutErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errors: The sum of the outgoing frame aborts and FCS errors."
::= { ifJnxEntry 24 }
ifJnxCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Collisions: The number of output collisions detected on this
interface."
::= { ifJnxEntry 25 }
ifJnxCarrierTrans OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier transitions: The number of times the interface saw
the carrier signal transition."
::= { ifJnxEntry 26 }
ifJnxOutQDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Drops: The number of packets dropped by the output queue of
the I/O Manager ASIC."
::= { ifJnxEntry 27 }
ifJnxOutAgedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Aged packets: The number of packets that remained in shared
packet SDRAM for so long that the system automatically purged
them."
::= { ifJnxEntry 28 }
ifJnxOutFifoErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FIFO errors: The number of FIFO errors in the transmit
direction as reported by the ASIC on the PIC."
::= { ifJnxEntry 29 }
ifJnxOutHslFifoUnderFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS link FIFO underflows: The number of FIFO underflows on the
high-speed links between the ASICs responsible for handling
the router interfaces."
::= { ifJnxEntry 30 }
ifJnxOutHslCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS Link CRC Errors: The number of CRC errors on the
high-speed links between the ASICs responsible for handling
the router interfaces while transmitting packets."
::= { ifJnxEntry 31 }
ifJnxCrcErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CRC Errors: The number of CRC errors"
::= { ifJnxEntry 32 }
ifJnxFcsErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FCS Errors: The number of FCS errors"
::= { ifJnxEntry 33 }
ifHCIn1SecOctets OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes per second (Bps), delivered by
this (sub-)layer to its next higher (sub-)layer.
This object is a 64 bit version of ifIn1SecOctets."
::= { ifJnxEntry 34 }
ifHCOut1SecOctets OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes per second (Bps), delivered by
this (sub-)layer to its next lower (sub-)layer.
This object is a 64 bit version of ifOut1SecOctets."
::= { ifJnxEntry 35 }
ifJnxInputErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errors: Includes all the input errors except the L3 incompletes
Same as ifJnxInErrors - ifJnxInL3Incompletes"
::= { ifJnxEntry 36 }
--
-- This table augments ifTable to map to Chassis MIB tables
--
ifChassisTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table to facilitate the identification of interfaces and
its mapping into the Chassis MIB tables."
::= { ifJnx 2 }
ifChassisEntry OBJECT-TYPE
SYNTAX IfChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
AUGMENTS { ifEntry }
::= { ifChassisTable 1 }
IfChassisEntry ::=
SEQUENCE {
ifChassisFpc Integer32,
ifChassisPic Integer32,
ifChassisPort Integer32,
ifChassisChannel Integer32,
ifChassisLogicalUnit Unsigned32,
ifChassisPicIndex OCTET STRING
}
ifChassisFpc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the FPC card on which the interface
is located in the chassis. It is the chassis slot
in which the FPC card is installed for the specified
interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical FPC associated with the specified interface."
::= { ifChassisEntry 1 }
ifChassisPic OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the PIC card on which the interface
is located in the chassis. It is the PIC location
on the FPC card for the specified interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical PIC associated with the specified interface."
::= { ifChassisEntry 2 }
ifChassisPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port on the PIC card on which the
interface is located in the chassis. It is the port
number on the PIC card for the specified interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical port associated with the specified interface."
::= { ifChassisEntry 3 }
ifChassisChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel identifier for the specified interface
if and only if it is part of a channelized interface.
Although the channel is numbered from 0 and up in the
interface naming, the return value for this object
always starts from 1 according to Network Management
convention. For the interface which could not be
channelized, this object returns zero."
::= { ifChassisEntry 4 }
ifChassisLogicalUnit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logical unit number of the specified interface.
It is the logical part of the interface that is
configured on the physical or channel part if any.
Although the logical unit number is numbered from 0 and
up in the interface naming, the return value for this
object always starts from 1 according to Network
Management convention. For the interface which is
really a physical device, this value returns zero."
::= { ifChassisEntry 5 }
ifChassisPicIndex OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index or indices for the Chassis MIB tables.
This is the instance index which keys into the
jnxContentsTable in Chassis MIB.
For example, it could return an octet string of
'8.1.2.0' - meaning a PIC ('8', first digit)
at FPC slot 0 ('1-1', second digit minus one if nonzero)
PIC number 1 ('2-1', third digit minus one if nonzero)
port number whatever (fourth digit currently unused)
- which in turn could be plugged in by NMS directly
after any MIB objects in the jnxContentsTable, say
'jnxContentsDescr.8.1.2.0', so NMS could get that
PIC object for the specified interface.
This object is valid only for those interfaces having
real and physical PIC cards. Otherwise, it returns
an octet string of four zeros '0.0.0.0.'"
::= { ifChassisEntry 6 }
--
-- This branch contains all Interface Level PFE Notifications data.
--
ifJnxNotification OBJECT IDENTIFIER ::= { ifJnx 3 }
ifJnxNotificationPrefix OBJECT IDENTIFIER ::= { ifJnxNotification 0}
ifJnxErrors NOTIFICATION-TYPE
OBJECTS {
ifJnxCrcErrors,
ifJnxFcsErrors
}
STATUS current
DESCRIPTION
"A ifJnxErrors notification is sent when the value
of ifJnxCrcErrors or ifJnxFcsErrors increases."
::= { ifJnxNotificationPrefix 1 }
--
-- This table augments ifTable
--
ifJnxPolTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJnxPolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table."
::= { ifJnx 4 }
ifJnxPolEntry OBJECT-TYPE
SYNTAX IfJnxPolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
INDEX { ifIndex }
::= { ifJnxPolTable 1 }
IfJnxPolEntry ::=
SEQUENCE {
ifJnxInPolLowOctets Counter64,
ifJnxInPolLowPkts Counter64,
ifJnxInPolLow1SecRate Counter64,
ifJnxInPolMLowOctets Counter64,
ifJnxInPolMLowPkts Counter64,
ifJnxInPolMLow1SecRate Counter64,
ifJnxInPolMHighOctets Counter64,
ifJnxInPolMHighPkts Counter64,
ifJnxInPolMHigh1SecRate Counter64,
ifJnxInPolHighOctets Counter64,
ifJnxInPolHighPkts Counter64,
ifJnxInPolHigh1SecRate Counter64,
ifJnxInPolDropOctets Counter64,
ifJnxInPolDropPkts Counter64,
ifJnxInPolDrop1SecRate Counter64,
ifJnxOutPolLowOctets Counter64,
ifJnxOutPolLowPkts Counter64,
ifJnxOutPolLow1SecRate Counter64,
ifJnxOutPolMLowOctets Counter64,
ifJnxOutPolMLowPkts Counter64,
ifJnxOutPolMLow1SecRate Counter64,
ifJnxOutPolMHighOctets Counter64,
ifJnxOutPolMHighPkts Counter64,
ifJnxOutPolMHigh1SecRate Counter64,
ifJnxOutPolHighOctets Counter64,
ifJnxOutPolHighPkts Counter64,
ifJnxOutPolHigh1SecRate Counter64,
ifJnxOutPolDropOctets Counter64,
ifJnxOutPolDropPkts Counter64,
ifJnxOutPolDrop1SecRate Counter64
}
ifJnxInPolLowOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Low Bytes"
::= { ifJnxPolEntry 1 }
ifJnxInPolLowPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Low Pkts"
::= { ifJnxPolEntry 2 }
ifJnxInPolLow1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Low 1 Sec Rate"
::= { ifJnxPolEntry 3 }
ifJnxInPolMLowOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium Low Bytes"
::= { ifJnxPolEntry 4 }
ifJnxInPolMLowPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium Low Pkts"
::= { ifJnxPolEntry 5 }
ifJnxInPolMLow1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium Low 1 Sec Rate"
::= { ifJnxPolEntry 6 }
ifJnxInPolMHighOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium High Bytes"
::= { ifJnxPolEntry 7 }
ifJnxInPolMHighPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium High Pkts"
::= { ifJnxPolEntry 8 }
ifJnxInPolMHigh1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium High 1 Sec Rate"
::= { ifJnxPolEntry 9 }
ifJnxInPolHighOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input High Bytes"
::= { ifJnxPolEntry 10 }
ifJnxInPolHighPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input High Pkts"
::= { ifJnxPolEntry 11 }
ifJnxInPolHigh1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input High 1 Sec Rate"
::= { ifJnxPolEntry 12 }
ifJnxInPolDropOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Drop Bytes"
::= { ifJnxPolEntry 13 }
ifJnxInPolDropPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Drop Pkts"
::= { ifJnxPolEntry 14 }
ifJnxInPolDrop1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Drop 1 Sec Rate"
::= { ifJnxPolEntry 15 }
ifJnxOutPolLowOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Low Bytes"
::= { ifJnxPolEntry 16 }
ifJnxOutPolLowPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Low Pkts"
::= { ifJnxPolEntry 17 }
ifJnxOutPolLow1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Low 1 Sec Rate"
::= { ifJnxPolEntry 18 }
ifJnxOutPolMLowOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Medium Low Bytes"
::= { ifJnxPolEntry 19 }
ifJnxOutPolMLowPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Input Medium Low Pkts"
::= { ifJnxPolEntry 20 }
ifJnxOutPolMLow1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Medium Low 1 Sec Rate"
::= { ifJnxPolEntry 21 }
ifJnxOutPolMHighOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Medium High Bytes"
::= { ifJnxPolEntry 22 }
ifJnxOutPolMHighPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Medium High Pkts"
::= { ifJnxPolEntry 23 }
ifJnxOutPolMHigh1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Medium High 1 Sec Rate"
::= { ifJnxPolEntry 24 }
ifJnxOutPolHighOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output High Bytes"
::= { ifJnxPolEntry 25 }
ifJnxOutPolHighPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output High Pkts"
::= { ifJnxPolEntry 26 }
ifJnxOutPolHigh1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output High 1 Sec Rate"
::= { ifJnxPolEntry 27 }
ifJnxOutPolDropOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Drop Bytes"
::= { ifJnxPolEntry 28 }
ifJnxOutPolDropPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Drop Pkts"
::= { ifJnxPolEntry 29 }
ifJnxOutPolDrop1SecRate OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Logical Interface Policer Output Drop 1 Sec Rate"
::= { ifJnxPolEntry 30 }
--
-- This table augments ifTable
--
ifJnxMediaTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJnxMediaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface media entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table."
::= { ifJnx 5 }
ifJnxMediaEntry OBJECT-TYPE
SYNTAX IfJnxMediaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
INDEX { ifIndex }
::= { ifJnxMediaTable 1 }
IfJnxMediaEntry ::=
SEQUENCE {
ifJnxMediaType INTEGER,
ifJnxMediaConfigSpeed Gauge32,
ifJnxMediaSpeed Gauge32,
ifJnxMediaMaxSpeed Gauge32,
ifJnxMediaMode INTEGER,
ifJnxMediaConfigMode INTEGER,
ifJnxMediaAutoNegotiationEnabled TruthValue,
ifJnxMediaLastFlap TimeTicks,
ifJnxMediaLastUpdate TimeTicks,
ifJnxMediaConfigHighSpeed Gauge32,
ifJnxMediaConfigSpeedMap BITS,
ifJnxMediaHighSpeed Gauge32
}
ifJnxMediaType OBJECT-TYPE
SYNTAX INTEGER {
copper(1),
fiber(2),
others(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Media type of an interface."
::= { ifJnxMediaEntry 1 }
ifJnxMediaConfigSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's configured bandwidth in bits
per second. If the bandwidth of the interface is greater than the
maximum value reportable by this object then this object should
report its maximum value (4,294,967,295) and
ifJnxMediaConfigHighSpeed must be used to report the interface's
config speed. An interface which is configured to auto-negotiate,
this speed will be zero. An interface which is configured to
auto-negotiate with 10m-100m, this speed will be one."
::= { ifJnxMediaEntry 2 }
ifJnxMediaSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's current bandwidth in bits
per second. If the bandwidth of the interface is greater than the
maximum value reportable by this object then this object should
report its maximum value (4,294,967,295). For a sub-layer which has
no concept of bandwidth, this object should be zero."
::= { ifJnxMediaEntry 3 }
ifJnxMediaMaxSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of maximum Speed that an interface can support in units
of Gbps."
::= { ifJnxMediaEntry 4 }
ifJnxMediaMode OBJECT-TYPE
SYNTAX INTEGER {
halfDuplex(1),
fullDuplex(2),
others(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An interface's current link mode."
::= { ifJnxMediaEntry 5 }
ifJnxMediaConfigMode OBJECT-TYPE
SYNTAX INTEGER {
halfDuplex(1),
fullDuplex(2),
auto(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An interface's configured link mode."
::= { ifJnxMediaEntry 6 }
ifJnxMediaAutoNegotiationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The truth value used to indicate whether port Auto-negotiation
is enabled on the given physical port."
::= { ifJnxMediaEntry 7 }
ifJnxMediaLastFlap OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of time from the last flap of interface state."
::= { ifJnxMediaEntry 8 }
ifJnxMediaLastUpdate OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of time from the last update of interface state."
::= { ifJnxMediaEntry 9 }
ifJnxMediaConfigHighSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's configured bandwidth in units
of 1,000,000 bits per second. For interfaces
which do not vary in bandwidth or for those where no
accurate estimation can be made, this object should contain
the nominal bandwidth."
::= { ifJnxMediaEntry 10 }
ifJnxMediaConfigSpeedMap OBJECT-TYPE
SYNTAX BITS {
auto(0),
mbps10(1),
mbps100(2),
mbps1000(3),
mbps2500(4),
mbps5000(5),
mbps10000(6),
mbps25000(7),
mbps40000(8),
mbps50000(9),
mbps100000(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's configured bandwidth.
The bit 'auto(0)' indicates that the speed configured is
auto-negotiation.
The bit 'mbps10(1)' indicates that the speed configured is
10mbps.
The bit 'mbps100(2)' indicates that the speed configured is
100mbps.
The bit 'mbps1000(3)' indicates that the speed configured is
1000mbps.
The bit 'mbps2500(4)' indicates that the speed configured is
2500mbps.
The bit 'mbps5000(5)' indicates that the speed configured is
5000mbps.
The bit 'mbps10000(6)' indicates that the speed configured is
10000mbps.
The bit 'mbps25000(7)' indicates that the speed configured is
25000mbps.
The bit 'mbps40000(8)' indicates that the speed configured is
40000mbps.
The bit 'mbps50000(9)' indicates that the speed configured is
50000mbps.
The bit 'mbps100000(10)' indicates that the speed configured is
100000mbps."
::= { ifJnxMediaEntry 11 }
ifJnxMediaHighSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's current bandwidth in units
of 1,000,000 bits per second. For interfaces
which do not vary in bandwidth or for those where no
accurate estimation can be made, this object should contain
the nominal bandwidth."
::= { ifJnxMediaEntry 12 }
END