-- Juniper-UNI-ATM-MIB
|
|
--
|
|
-- Juniper Networks Enterprise MIB
|
|
-- ATM MIB
|
|
--
|
|
-- Copyright (c) 1999 Redstone Communications, Inc.
|
|
-- Copyright (c) 1999, 2002 Unisphere Networks, Inc.
|
|
-- Copyright (c) 2002, 2005 Juniper Networks, Inc.
|
|
-- All Rights Reserved.
|
|
-- *****************************************************************************
|
|
|
|
Juniper-UNI-ATM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32,
|
|
Unsigned32, Counter64, Counter32, IpAddress, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, RowStatus, TruthValue, TimeStamp, DisplayString
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
InterfaceIndex, InterfaceIndexOrZero, ifIndex
|
|
FROM IF-MIB
|
|
AtmVpIdentifier, AtmVcIdentifier, AtmVorXAdminStatus, AtmAddr
|
|
FROM ATM-TC-MIB
|
|
atmVplVpi, atmVclVpi, atmVclVci
|
|
FROM ATM-MIB
|
|
atmfM4VpTestObject, atmfM4VpTestId, atmfM4VpTestType, atmfM4VpTestResult,
|
|
atmfM4VcTestObject, atmfM4VcTestId, atmfM4VcTestType, atmfM4VcTestResult,
|
|
atmfM4VpTestCode, atmfM4VcTestCode
|
|
FROM ATM-FORUM-SNMP-M4-MIB
|
|
juniMibs
|
|
FROM Juniper-MIBs
|
|
JuniNextIfIndex, JuniEnable, JuniInterfaceLocationType,
|
|
JuniInterfaceLocationValue
|
|
FROM Juniper-TC;
|
|
|
|
juniAtmMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200511151133Z" -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
|
|
ORGANIZATION "Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
" Juniper Networks, Inc.
|
|
Postal: 10 Technology Park Drive
|
|
Westford, MA 01886-3146
|
|
USA
|
|
Tel: +1 978 589 5800
|
|
Email: mib@Juniper.net"
|
|
DESCRIPTION
|
|
"The ATM MIB for the Juniper enterprise."
|
|
REVISION "200511151133Z" -- 15-Nov-05 11:33 AM EST - JUNOSe 7.3
|
|
DESCRIPTION
|
|
"Added ATM VC Class support"
|
|
-- Revision History
|
|
REVISION "200508171726Z" -- 17-Aug-05 01:26 PM EDT - JUNOSe 7.3
|
|
DESCRIPTION
|
|
"Removed support for:
|
|
juniAtmIfSvcSignallingTable
|
|
juniAtmIfPnniRccTable
|
|
juniAtmSubIfAddress
|
|
juniAtmSubIfSvcConfigTable."
|
|
REVISION "200502172315Z" -- 17-Feb-05 06:15 PM EST - JUNOSe 7.1
|
|
DESCRIPTION
|
|
"Added the following to juniAtmCircuitOamTable:
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps
|
|
juniAtmCircuitOamUpCount
|
|
juniAtmCircuitOamDownCount
|
|
juniAtmCircuitOamRetryFrequency
|
|
juniAtmCircuitOamAlarmDownCount
|
|
juniAtmCircuitOamAlarmClearTimeout
|
|
Added the following to juniAtmF4FlowOamEndToEndStatsTable:
|
|
juniAtmF4FlowEndToEndInLoopbackCmds
|
|
juniAtmF4FlowEndToEndInLoopbackRsps
|
|
juniAtmF4FlowEndToEndOutLoopbackCmds
|
|
juniAtmF4FlowEndToEndOutLoopbackRsps
|
|
Added the following to juniAtmF4FlowOamSegmentStatsTable:
|
|
juniAtmF4FlowSegmentInLoopbackCmds
|
|
juniAtmF4FlowSegmentInLoopbackRsps
|
|
juniAtmF4FlowSegmentOutLoopbackCmds
|
|
juniAtmF4FlowSegmentOutLoopbackRsps"
|
|
REVISION "200412081522Z" -- 08-Dec-04 10:22 AM EST - JUNOSe 7.0
|
|
DESCRIPTION
|
|
"Added aal0 and aal5 values to juniAtmSubIfVccType enumeration.
|
|
Added ATM Martini cell aggregation configuration objects.
|
|
Added profile override support.
|
|
Added bulk-configuration modification support."
|
|
REVISION "200312301507Z" -- 25-Feb-04 03:23 PM EST - JUNOSe 6.0
|
|
DESCRIPTION
|
|
"Added second generation E-series platform support:
|
|
Imported JuniInterfaceLocationType and JuniInterfaceLocationValue
|
|
from Juniper-TC to replace JuniAtmLocationType and
|
|
JuniAtmLocationValue textual conventions, respectively."
|
|
REVISION "200402252023Z" -- 25-Feb-04 03:23 PM EST - JUNOSe 5.3
|
|
DESCRIPTION
|
|
"Added support to export the subinterface description to the line
|
|
cards. Added advisory receive support for subinterfaces."
|
|
REVISION "200309192201Z" -- 19-Sep-03 06:01 PM EDT - JUNOSe 5.2
|
|
DESCRIPTION
|
|
"Added JuniAtmLocationType and JuniAtmLocationValue textual conventions.
|
|
Added juniAtmSubIfLocationType and juniAtmSubIfLocationTable."
|
|
REVISION "200307141537Z" -- 14-Jul-03 11:37 AM EDT - JUNOSe 5.1
|
|
DESCRIPTION
|
|
"Added F4 flow OAM circuit support.
|
|
Added ATM VP description support.
|
|
Added bulk circuit configuration support.
|
|
Corrected enumeration values for UNI signalling versions."
|
|
REVISION "200301151932Z" -- 15-Jan-03 02:32 PM EST - JUNOSe 5.0
|
|
DESCRIPTION
|
|
"Replaced Unisphere names with Juniper names.
|
|
Changed the juniAtmVcPingProbeCount Range to match CLI.
|
|
Added null value for juniAtmSubIfVccType."
|
|
REVISION "200208091403Z" -- 09-Aug-02 10:03 AM EDT - JUNOSe 4.1
|
|
DESCRIPTION
|
|
"Added receive bandwith support to CAC.
|
|
Added E164 public addressing support.
|
|
Added PNNI RCC table support.
|
|
Added ATM1483 interface MTU config support."
|
|
REVISION "200208091340Z" -- 09-Aug-02 09:40 AM EDT - JUNOSe 4.0
|
|
DESCRIPTION
|
|
"Added support for CAC used bandwidth.
|
|
Added ATM switched virtual connection (SVC) support.
|
|
Added juniAtmSubIfAddress to the juniAtmSubIfTable."
|
|
REVISION "200201241400Z" -- 24-Jan-02 09:00 AM EST - JUNOSe 3.4
|
|
DESCRIPTION
|
|
"Added support for connection admission control (CAC)."
|
|
REVISION "200112141804Z" -- 14-Dec-01 01:04 PM EST - JUNOSe 3.3
|
|
DESCRIPTION
|
|
"Added support from ATM traffic shaping."
|
|
REVISION "200111261639Z" -- 26-Nov-01 11:39 AM EST - JUNOSe 3.2
|
|
DESCRIPTION
|
|
"Added support for NBMA map lists.
|
|
Added support for ATM ping.
|
|
Changed juniAtmSubIfVccVcd and juniAtmIfIlmiVcd ranges to
|
|
(0..2147483647).
|
|
Added range to juniAtmIfCapabilityMaxVcd.
|
|
Added rtVbr service catagory to juniAtmSubIfVccTable.
|
|
Added support for OAM cell filter.
|
|
Added PVC counter for reveived unknown protocol."
|
|
REVISION "200011271951Z" -- 27-Nov-00 02:51 PM EST - JUNOSe 3.0
|
|
DESCRIPTION
|
|
"Added autoconfig value for juniAtmSubIfVccType.
|
|
Added in/out summary cell counters.
|
|
Added juniVpTunnelServiceCategory to juniAtmVpTunnelTable.
|
|
Added support for atm interface capability traversal."
|
|
REVISION "200008020000Z" -- 02-Aug-00 - JUNOSe 2.3
|
|
DESCRIPTION
|
|
"Added the juniAtmCircuitOamTable."
|
|
REVISION "200005120000Z" -- 12-May-00 - JUNOSe 2.0
|
|
DESCRIPTION
|
|
"Added the juniAtmVpTunnelTable."
|
|
REVISION "200001130000Z" -- 13-Jan-00 - JUNOSe 1.3
|
|
DESCRIPTION
|
|
"Added the juniAtmPvcStatisticsTable."
|
|
REVISION "9908040000Z" -- 04-Aug-99 - JUNOSe 1.1
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { juniMibs 8 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Textual conventions
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
JuniAtmNbmaMapName ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "32a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administratively assigned map name. Represents textual information
|
|
taken from the NVT ASCII character set. The name must be unique per
|
|
system."
|
|
REFERENCE
|
|
"RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
|
|
DESCRIPTION for a summary."
|
|
SYNTAX OCTET STRING (SIZE(1..32))
|
|
|
|
JuniAtmNbmaMapNameOrNull ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "32a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administratively assigned map name. Represents textual information
|
|
taken from the NVT ASCII character set. The name must be unique per
|
|
system.
|
|
|
|
Differs from JuniAtmNbmaMapName in that it permits a zero-length
|
|
string."
|
|
REFERENCE
|
|
"RFC 854: NVT ASCII character set. See SNMPv2-TC.DisplayString
|
|
DESCRIPTION for a summary."
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
|
|
JuniAtmLocationType ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete description of the platform-dependent interpretation of a
|
|
JuniAtmLocationValue object. This textual convention has been relpaced
|
|
by Juniper-TC.JuniInterfaceLocationType."
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
slotPort(1) }
|
|
|
|
JuniAtmLocationValue ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete value of a platform-dependent interface location, represented
|
|
as an OCTET STRING. A corresponding JuniAtmLocationType object
|
|
identified the mapping of octets to location elements, e.g. 'slot.port'.
|
|
This textual convention has been replaced by
|
|
Juniper-TC.JuniInterfaceLocationValue."
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Managed objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniAtmObjects OBJECT IDENTIFIER ::= { juniAtmMIB 1 }
|
|
|
|
--
|
|
-- This MIB contains managed objects for each of three interface layers: ATM;
|
|
-- AAL5; and ATM Subinterface. For each of these layers, management objects are
|
|
-- provided to query for an available interface index, and to create/delete
|
|
-- interfaces of that type. Creating/deleting these interface types using this
|
|
-- MIB has the side effect of creating/deleting corresponding entries in the
|
|
-- Interface MIB ifTable/ifXTable, and in the Juniper Enterprise Interface MIB
|
|
-- juniIfTable.
|
|
--
|
|
juniAtmIfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 1 }
|
|
juniAtmAal5IfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 2 }
|
|
juniAtmSubIfLayer OBJECT IDENTIFIER ::= { juniAtmObjects 3 }
|
|
juniAtmNbma OBJECT IDENTIFIER ::= { juniAtmObjects 4 }
|
|
juniAtmPing OBJECT IDENTIFIER ::= { juniAtmObjects 5 }
|
|
juniAtmLocation OBJECT IDENTIFIER ::= { juniAtmObjects 6 }
|
|
juniAtmVcClass OBJECT IDENTIFIER ::= { juniAtmObjects 7}
|
|
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- ATM LAYER
|
|
--
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- IfIndex selection for creating new ATM interfaces
|
|
--
|
|
juniAtmNextIfIndex OBJECT-TYPE
|
|
SYNTAX JuniNextIfIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Coordinate ifIndex value allocation for entries in juniAtmIfTable.
|
|
|
|
A GET of this object returns the next available ifIndex value to be used
|
|
to create an entry in the associated interface table; or zero, if no
|
|
valid ifIndex value is available. This object also returns a value of
|
|
zero when it is the lexicographic successor of a varbind presented in an
|
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
|
that ifIndex allocation is unintended.
|
|
|
|
Successive GETs will typically return different values, thus avoiding
|
|
collisions among cooperating management clients seeking to create table
|
|
entries simultaneously."
|
|
::= { juniAtmIfLayer 1 }
|
|
|
|
--
|
|
-- The ATM Interface Table
|
|
--
|
|
juniAtmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM interfaces present in the system."
|
|
::= { juniAtmIfLayer 2 }
|
|
|
|
juniAtmIfEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM interface.
|
|
Creating/deleting entries in this table causes corresponding entries for
|
|
be created/deleted in ifTable/ifXTable/juniIfTable."
|
|
INDEX { juniAtmIfIndex }
|
|
::= { juniAtmIfTable 1 }
|
|
|
|
JuniAtmIfEntry ::= SEQUENCE {
|
|
juniAtmIfIndex InterfaceIndex,
|
|
juniAtmIfRowStatus RowStatus,
|
|
juniAtmIfLowerIfIndex InterfaceIndexOrZero,
|
|
juniAtmIfIlmiVpi AtmVpIdentifier,
|
|
juniAtmIfIlmiVci AtmVcIdentifier,
|
|
juniAtmIfIlmiVcd Integer32,
|
|
juniAtmIfIlmiPollFrequency Integer32,
|
|
juniAtmIfIlmiAdminState INTEGER,
|
|
juniAtmIfUniVersion INTEGER,
|
|
juniAtmIfOamCellRxAdminState INTEGER,
|
|
juniAtmIfInCells Counter64,
|
|
juniAtmIfOutCells Counter64,
|
|
juniAtmIfVcCount Integer32,
|
|
juniAtmIfMapGroup JuniAtmNbmaMapNameOrNull,
|
|
juniAtmIfCacAdminState JuniEnable,
|
|
juniAtmIfCacUbrWeight Integer32,
|
|
juniAtmIfCacSubscriptionBandwidth Integer32,
|
|
juniAtmIfCacAvailableBandwidth Integer32,
|
|
juniAtmIfCacAvailableBandwidthRx Integer32,
|
|
juniAtmIfE164Autoconversion INTEGER,
|
|
juniAtmIfE164Gateway INTEGER,
|
|
juniAtmIfE164OneToOneAddrTrans INTEGER,
|
|
juniAtmIfOamCellFilter INTEGER,
|
|
juniAtmIfCacUsedBandwidthUpper Unsigned32,
|
|
juniAtmIfCacUsedBandwidthLower Unsigned32,
|
|
juniAtmIfAssociatedVcClassId Unsigned32 }
|
|
|
|
juniAtmIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface. When creating entries in this table,
|
|
suitable values for this object are determined by reading
|
|
juniAtmNextIfIndex."
|
|
::= { juniAtmIfEntry 1 }
|
|
|
|
juniAtmIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create an entry in this table, the following entry objects MUST be
|
|
explicitly configured:
|
|
juniAtmIfRowStatus
|
|
juniAtmIfLowerIfIndex
|
|
|
|
In addition, when creating an entry the following condition must hold:
|
|
A value for juniAtmIfIndex must have been determined previously, by
|
|
reading juniAtmNextIfIndex.
|
|
|
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
|
|
destroyed as a result of creating/destroying an entry in this table."
|
|
::= { juniAtmIfEntry 2 }
|
|
|
|
juniAtmIfLowerIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of an interface over which this ATM interface is to be
|
|
layered. A value of zero indicates no layering. An implementation may
|
|
choose to require that a nonzero value be configured at entry creation."
|
|
::= { juniAtmIfEntry 3 }
|
|
|
|
juniAtmIfIlmiVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the ILMI of a major ATM interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfEntry 4 }
|
|
|
|
juniAtmIfIlmiVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the ILMI of a major ATM interface."
|
|
DEFVAL { 16 }
|
|
::= { juniAtmIfEntry 5 }
|
|
|
|
juniAtmIfIlmiVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer identifier for the ILMI, used in conjunction with the
|
|
command-line interface.
|
|
|
|
The value must be unique among VCs configured on the same ATM
|
|
interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfEntry 6 }
|
|
|
|
juniAtmIfIlmiPollFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time in seconds between successive transmissions of ILMI
|
|
messages on this interface for the purpose of detecting loss of ILMI
|
|
connectivity. The distinguished value zero disables ILMI connectivity
|
|
procedures on this interface."
|
|
::= { juniAtmIfEntry 7 }
|
|
|
|
juniAtmIfIlmiAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative status of ILMI in the ATM interface."
|
|
::= { juniAtmIfEntry 8 }
|
|
|
|
juniAtmIfUniVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uniVersionAutoConfig(0),
|
|
version3Dot0(1),
|
|
version3Dot1(2),
|
|
version4Dot0(3) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to specify the User Network Interface (UNI) the router should use
|
|
when ILMI link auto determination is unsuccesful or ILMI is disabled."
|
|
::= { juniAtmIfEntry 9 }
|
|
|
|
juniAtmIfOamCellRxAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamCellAdminStateDisabled(0),
|
|
oamCellAdminStateEnabled(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use to specify the OAM Cell Receive Administrative state on this
|
|
interface."
|
|
DEFVAL { oamCellAdminStateEnabled }
|
|
::= { juniAtmIfEntry 10 }
|
|
|
|
juniAtmIfInCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells received on this major interface."
|
|
::= { juniAtmIfEntry 11 }
|
|
|
|
juniAtmIfOutCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells transmitted on this major interface."
|
|
::= { juniAtmIfEntry 12 }
|
|
|
|
juniAtmIfVcCount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..268431360)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of circuits configured on this interface."
|
|
::= { juniAtmIfEntry 13 }
|
|
|
|
juniAtmIfMapGroup OBJECT-TYPE
|
|
SYNTAX JuniAtmNbmaMapNameOrNull
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NBMA map group this interface is associated with."
|
|
DEFVAL { "" }
|
|
::= { juniAtmIfEntry 14 }
|
|
|
|
juniAtmIfCacAdminState OBJECT-TYPE
|
|
SYNTAX JuniEnable
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative staus of CAC on this ATM major interface."
|
|
DEFVAL { disable }
|
|
::= { juniAtmIfEntry 15 }
|
|
|
|
juniAtmIfCacUbrWeight OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bandwidth associated with every UBR and UBR with PCR connection
|
|
configured on the ATM major interface. This value is used for CAC
|
|
computation. The units are kilo-bits per second (kbps)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfEntry 16 }
|
|
|
|
juniAtmIfCacSubscriptionBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The subscribed bandwidth of the ATM major interface. If this value is
|
|
not specified or set to 0, the effective port bandwidth is used. When a
|
|
Get operation is performed the current effective bandwidth is returned.
|
|
The units are kilo-bits per second (kbps)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfEntry 17 }
|
|
|
|
juniAtmIfCacAvailableBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The available bandwidth in Tx direction of the ATM major interface. As
|
|
connections are added or deleted on the interface, this value is
|
|
updated. The units are kilo-bits per second (kbps)."
|
|
::= { juniAtmIfEntry 18 }
|
|
|
|
juniAtmIfCacAvailableBandwidthRx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The available bandwidth in Rx direction of the ATM major interface. As
|
|
connections are added or deleted on the interface, this value is
|
|
updated. The units are kilo-bits per second (kbps)."
|
|
::= { juniAtmIfEntry 19 }
|
|
|
|
juniAtmIfE164Autoconversion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The status of E164 autoconversion feature in the ATM interface."
|
|
::= { juniAtmIfEntry 20 }
|
|
|
|
juniAtmIfE164Gateway OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The status of E164 gateway feature in the ATM interface."
|
|
::= { juniAtmIfEntry 21 }
|
|
|
|
juniAtmIfE164OneToOneAddrTrans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The status of E164 one-to-one address translation feature in the ATM
|
|
interface."
|
|
::= { juniAtmIfEntry 22 }
|
|
|
|
juniAtmIfOamCellFilter OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamCellFilterAll(0),
|
|
oamCellFilterAlarm(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of OAM cells to discard when juniAtmIfOamCellRxAdminState is
|
|
set to oamCellAdminStateDisabled. The value oamCellFilterAlarm discards
|
|
received OAM AIS and RDI cells. The value oamCellFilterAll discards all
|
|
received OAM cells. Note that when juniAtmIfOamCellRxAdminState is set
|
|
to oamCellAdminStateEnabled, this object has no effect."
|
|
DEFVAL { oamCellFilterAll }
|
|
::= { juniAtmIfEntry 23 }
|
|
|
|
juniAtmIfCacUsedBandwidthUpper OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The most significant 32 bits of the CAC used bandwidth on the ATM major
|
|
interface. The least significant 32 bits of the CAC used bandwidth are
|
|
specified by juniAtmIfCacUsedBandwidthLower."
|
|
::= { juniAtmIfEntry 24 }
|
|
|
|
juniAtmIfCacUsedBandwidthLower OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The least significant 32 bits of the CAC used bandwidth on the ATM
|
|
major interface. The most significant 32 bits of the CAC used bandwidth
|
|
are specified by juniAtmIfCacUsedBandwidthUpper."
|
|
::= { juniAtmIfEntry 25 }
|
|
|
|
juniAtmIfAssociatedVcClassId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier of the ATM VC class associated with this ATM interface. A value for this identifier is determined by locating or creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0 means no VC class association exists for this interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfEntry 26 }
|
|
|
|
|
|
--
|
|
-- The ATM VPI/VCI Statistics Table
|
|
--
|
|
juniAtmPvcStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmPvcStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains statistics for PVC entries."
|
|
::= { juniAtmIfLayer 3 }
|
|
|
|
juniAtmPvcStatisticsEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmPvcStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides statistics on an ATM PVC."
|
|
INDEX { juniAtmPvcStatsIfIndex,
|
|
juniAtmPvcStatsVpi,
|
|
juniAtmPvcStatsVci }
|
|
::= { juniAtmPvcStatisticsTable 1 }
|
|
|
|
JuniAtmPvcStatisticsEntry ::= SEQUENCE {
|
|
juniAtmPvcStatsIfIndex InterfaceIndex,
|
|
juniAtmPvcStatsVpi AtmVpIdentifier,
|
|
juniAtmPvcStatsVci AtmVcIdentifier,
|
|
juniAtmPvcStatsInCells Counter64,
|
|
juniAtmPvcStatsInCellOctets Counter64,
|
|
juniAtmPvcStatsInPackets Counter64,
|
|
juniAtmPvcStatsInPacketOctets Counter64,
|
|
juniAtmPvcStatsOutCells Counter64,
|
|
juniAtmPvcStatsOutCellOctets Counter64,
|
|
juniAtmPvcStatsOutPackets Counter64,
|
|
juniAtmPvcStatsOutPacketOctets Counter64,
|
|
juniAtmPvcStatsInCellErrors Counter32,
|
|
juniAtmPvcStatsinPacketErrors Counter32,
|
|
juniAtmPvcStatsOutCellErrors Counter32,
|
|
juniAtmPvcStatsOutPacketErrors Counter32,
|
|
juniAtmPvcStatsInPacketDiscards Counter32,
|
|
juniAtmPvcStatsInPacketOctetDiscards Counter32,
|
|
juniAtmPvcStatsInPacketUnknownProtocol Counter32 }
|
|
|
|
juniAtmPvcStatsIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface."
|
|
::= { juniAtmPvcStatisticsEntry 1 }
|
|
|
|
juniAtmPvcStatsVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the ATM VCC used by this ATM interface and PVC."
|
|
::= { juniAtmPvcStatisticsEntry 2 }
|
|
|
|
juniAtmPvcStatsVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the ATM VCC used by this ATM interface and PVC."
|
|
::= { juniAtmPvcStatisticsEntry 3 }
|
|
|
|
juniAtmPvcStatsInCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received cells."
|
|
::= { juniAtmPvcStatisticsEntry 4 }
|
|
|
|
juniAtmPvcStatsInCellOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received cells octets."
|
|
::= { juniAtmPvcStatisticsEntry 5 }
|
|
|
|
juniAtmPvcStatsInPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received AAL PDUs."
|
|
::= { juniAtmPvcStatisticsEntry 6 }
|
|
|
|
juniAtmPvcStatsInPacketOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received AAL PDU octets."
|
|
::= { juniAtmPvcStatisticsEntry 7 }
|
|
|
|
juniAtmPvcStatsOutCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted cells."
|
|
::= { juniAtmPvcStatisticsEntry 8 }
|
|
|
|
juniAtmPvcStatsOutCellOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted cell octets."
|
|
::= { juniAtmPvcStatisticsEntry 9 }
|
|
|
|
juniAtmPvcStatsOutPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted AAL PDUs."
|
|
::= { juniAtmPvcStatisticsEntry 10 }
|
|
|
|
juniAtmPvcStatsOutPacketOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted AAL PDU octets."
|
|
::= { juniAtmPvcStatisticsEntry 11 }
|
|
|
|
juniAtmPvcStatsInCellErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received cells dropped due to errors."
|
|
::= { juniAtmPvcStatisticsEntry 12 }
|
|
|
|
juniAtmPvcStatsinPacketErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets dropped due to errors."
|
|
::= { juniAtmPvcStatisticsEntry 13 }
|
|
|
|
juniAtmPvcStatsOutCellErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cells not transmitted due to errors."
|
|
::= { juniAtmPvcStatisticsEntry 14 }
|
|
|
|
juniAtmPvcStatsOutPacketErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Packets not transmitted due to errors."
|
|
::= { juniAtmPvcStatisticsEntry 15 }
|
|
|
|
juniAtmPvcStatsInPacketDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets w/o errors discarded."
|
|
::= { juniAtmPvcStatisticsEntry 16 }
|
|
|
|
juniAtmPvcStatsInPacketOctetDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received bytes w/o errors discarded."
|
|
::= { juniAtmPvcStatisticsEntry 17 }
|
|
|
|
juniAtmPvcStatsInPacketUnknownProtocol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets that are discarded because the interface can not
|
|
discern or is not configured to support this protocol."
|
|
::= { juniAtmPvcStatisticsEntry 18 }
|
|
|
|
--
|
|
-- The ATM Virtual Path Tunnel Table
|
|
--
|
|
juniAtmVpTunnelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVpTunnelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM VP Tunnels present in the system."
|
|
::= { juniAtmIfLayer 4 }
|
|
|
|
juniAtmVpTunnelEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVpTunnelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM VP Tunnel."
|
|
INDEX { juniAtmVpTunnelIfIndex,
|
|
juniAtmVpTunnelVpi }
|
|
::= { juniAtmVpTunnelTable 1 }
|
|
|
|
JuniAtmVpTunnelEntry ::= SEQUENCE {
|
|
juniAtmVpTunnelIfIndex InterfaceIndex,
|
|
juniAtmVpTunnelVpi AtmVpIdentifier,
|
|
juniAtmVpTunnelKbps Integer32,
|
|
juniAtmVpTunnelRowStatus RowStatus,
|
|
juniAtmVpTunnelServiceCategory INTEGER }
|
|
|
|
juniAtmVpTunnelIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface. The value of this object is the same
|
|
as the juniAtmIfIndex object in the juniAtmIfTable.
|
|
|
|
Entries in this table cannot be created unless the underlying ATM
|
|
interface entry is created first in the juniAtmIfTable."
|
|
::= { juniAtmVpTunnelEntry 1 }
|
|
|
|
juniAtmVpTunnelVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI value for this VP tunnel entry."
|
|
::= { juniAtmVpTunnelEntry 2 }
|
|
|
|
juniAtmVpTunnelKbps OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tunnel rate in kilobits per second (kbps) for this entry."
|
|
::= { juniAtmVpTunnelEntry 3 }
|
|
|
|
juniAtmVpTunnelRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create an entry in this table, the following entry objects MUST be
|
|
explicitly configured:
|
|
juniAtmVpTunnelRowStatus
|
|
juniAtmVpTunnelKbps
|
|
|
|
In addition, when creating an entry the following condition must hold:
|
|
A correponding juniAtmVpTunnelIfIndex value must have been created
|
|
in the juniAtmIfTable previously."
|
|
::= { juniAtmVpTunnelEntry 4 }
|
|
|
|
juniAtmVpTunnelServiceCategory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nrtVbr(1),
|
|
cbr(2) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM service category for the tunnel."
|
|
::= { juniAtmVpTunnelEntry 5 }
|
|
|
|
|
|
--
|
|
-- The ATM Interface Capability Table
|
|
--
|
|
juniAtmIfCapabilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmIfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM interfaces present in the system."
|
|
::= { juniAtmIfLayer 5 }
|
|
|
|
juniAtmIfCapabilityEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmIfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the capabilities of an ATM interface. A
|
|
management client can use this table to determine differences in the
|
|
configurable level of support across entries in this table."
|
|
INDEX { juniAtmIfCapabilityIndex }
|
|
::= { juniAtmIfCapabilityTable 1 }
|
|
|
|
JuniAtmIfCapabilityEntry ::= SEQUENCE {
|
|
juniAtmIfCapabilityIndex InterfaceIndex,
|
|
juniAtmIfCapabilityTrafficShaping TruthValue,
|
|
juniAtmIfCapabilityOam TruthValue,
|
|
juniAtmIfCapabilityDefaultVcPerVp Integer32,
|
|
juniAtmIfCapabilityNumVpiVciBits Integer32,
|
|
juniAtmIfCapabilityMaxVcd Integer32,
|
|
juniAtmIfCapabilityMaxVpi AtmVpIdentifier,
|
|
juniAtmIfCapabilityMaxVci AtmVcIdentifier,
|
|
juniAtmIfCapabilityOamCellFilter TruthValue }
|
|
|
|
juniAtmIfCapabilityIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface. The value of this object is the same
|
|
as juniAtmIfIndex in the juniAtmIfTable."
|
|
::= { juniAtmIfCapabilityEntry 1 }
|
|
|
|
juniAtmIfCapabilityTrafficShaping OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether traffic shaping is supported on this interface;
|
|
true(1) indicates that it is, false(2) indicates that it is not."
|
|
::= { juniAtmIfCapabilityEntry 2 }
|
|
|
|
juniAtmIfCapabilityOam OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether OAM is supported on this interface; true(1) indicates
|
|
that it is, false(2) indicates that it is not."
|
|
::= { juniAtmIfCapabilityEntry 3 }
|
|
|
|
juniAtmIfCapabilityDefaultVcPerVp OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65536)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default number of VCs per VP for this interface."
|
|
::= { juniAtmIfCapabilityEntry 4 }
|
|
|
|
juniAtmIfCapabilityNumVpiVciBits OBJECT-TYPE
|
|
SYNTAX Integer32 (8..28)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total range of bits used for constructing VPI/VCI identifiers for
|
|
this interface."
|
|
::= { juniAtmIfCapabilityEntry 5 }
|
|
|
|
juniAtmIfCapabilityMaxVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum configurable value for a VCD on this interface."
|
|
::= { juniAtmIfCapabilityEntry 6 }
|
|
|
|
juniAtmIfCapabilityMaxVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum configurable value for a VPI on this interface."
|
|
::= { juniAtmIfCapabilityEntry 7 }
|
|
|
|
juniAtmIfCapabilityMaxVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum configurable value for a VCI on this interface."
|
|
::= { juniAtmIfCapabilityEntry 8 }
|
|
|
|
juniAtmIfCapabilityOamCellFilter OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether OAM cell filter is supported on this interface;
|
|
true(1) indicates that it is, false(2) indicates that it is not."
|
|
::= { juniAtmIfCapabilityEntry 9 }
|
|
|
|
|
|
--
|
|
-- The juniAtmIfSvcSignallingTable extends the juniAtmIfTable for ATM switched
|
|
-- virtual connections (SVCs).
|
|
--
|
|
juniAtmIfSvcSignallingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmIfSvcSignallingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This table contains entries for extending the juniAtmIfTable for
|
|
configuring signalling information for switched virtual connection
|
|
(SVC)."
|
|
::= { juniAtmIfLayer 6 }
|
|
|
|
juniAtmIfSvcSignallingEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmIfSvcSignallingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Each entry provides configuration parameters for ATM signalling on the
|
|
interface."
|
|
INDEX { juniAtmIfIndex }
|
|
::= { juniAtmIfSvcSignallingTable 1 }
|
|
|
|
JuniAtmIfSvcSignallingEntry ::= SEQUENCE {
|
|
juniAtmIfSvcSignallingVpi AtmVpIdentifier,
|
|
juniAtmIfSvcSignallingVci AtmVcIdentifier,
|
|
juniAtmIfSvcSignallingVcd Integer32,
|
|
juniAtmIfSvcSignallingAdminStatus AtmVorXAdminStatus }
|
|
|
|
juniAtmIfSvcSignallingVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The VPI identifier of the ATM circuit used for signalling for this
|
|
interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfSvcSignallingEntry 1 }
|
|
|
|
juniAtmIfSvcSignallingVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The VCI identifier of the ATM circuit used for signalling for this
|
|
interface."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmIfSvcSignallingEntry 2 }
|
|
|
|
juniAtmIfSvcSignallingVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An integer identifier for the ATM circuit used for signalling on this
|
|
interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfSvcSignallingEntry 3 }
|
|
|
|
juniAtmIfSvcSignallingAdminStatus OBJECT-TYPE
|
|
SYNTAX AtmVorXAdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The administrative status of signalling on the ATM interface."
|
|
::= { juniAtmIfSvcSignallingEntry 4 }
|
|
|
|
|
|
--
|
|
-- The juniAtmIfPnniRccTable extends the juniAtmIfTable for PNNI Routing
|
|
-- Control Channel
|
|
--
|
|
juniAtmIfPnniRccTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmIfPnniRccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This table contains entries for extending the juniAtmIfTable for
|
|
configuring PNNI RCC information."
|
|
::= { juniAtmIfLayer 7 }
|
|
|
|
juniAtmIfPnniRccEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmIfPnniRccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Each entry provides configuration parameters for PNNI RCC on the
|
|
interface."
|
|
INDEX { juniAtmIfIndex }
|
|
::= { juniAtmIfPnniRccTable 1 }
|
|
|
|
JuniAtmIfPnniRccEntry ::= SEQUENCE {
|
|
juniAtmIfPnniRccVpi AtmVpIdentifier,
|
|
juniAtmIfPnniRccVci AtmVcIdentifier,
|
|
juniAtmIfPnniRccVcd Integer32,
|
|
juniAtmIfPnniRccAdminStatus AtmVorXAdminStatus }
|
|
|
|
juniAtmIfPnniRccVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The VPI identifier of the ATM circuit used for PNNI RCC on this
|
|
interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfPnniRccEntry 1 }
|
|
|
|
juniAtmIfPnniRccVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The VCI identifier of the ATM circuit used for PNNI RCC on this
|
|
interface."
|
|
DEFVAL { 18 }
|
|
::= { juniAtmIfPnniRccEntry 2 }
|
|
|
|
juniAtmIfPnniRccVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"An integer identifier for the ATM circuit used for PNNI RCC on this
|
|
interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmIfPnniRccEntry 3 }
|
|
|
|
juniAtmIfPnniRccAdminStatus OBJECT-TYPE
|
|
SYNTAX AtmVorXAdminStatus
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The administrative status of PNNI on the ATM interface."
|
|
::= { juniAtmIfPnniRccEntry 4 }
|
|
|
|
|
|
--
|
|
-- The juniAtmOamF4FlowEndToEndConfigTable
|
|
--
|
|
juniAtmOamF4FlowEndToEndCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmOamF4FlowEndToEndCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for F4 OAM end-to-end flows configured."
|
|
::= { juniAtmIfLayer 8 }
|
|
|
|
juniAtmOamF4FlowEndToEndCfgEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmOamF4FlowEndToEndCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides configuration parameters for one F4 OAM end-to-end
|
|
flow configured for each VPI."
|
|
INDEX { juniAtmOamF4FlowEndToEndIfIndex,
|
|
juniAtmOamF4FlowEndToEndVpi }
|
|
::= { juniAtmOamF4FlowEndToEndCfgTable 1 }
|
|
|
|
JuniAtmOamF4FlowEndToEndCfgEntry ::= SEQUENCE {
|
|
juniAtmOamF4FlowEndToEndIfIndex InterfaceIndex,
|
|
juniAtmOamF4FlowEndToEndVpi Integer32,
|
|
juniAtmOamF4FlowEndToEndLoopbackTimer Integer32,
|
|
juniAtmOamF4FlowEndToEndCCSink TruthValue,
|
|
juniAtmOamF4FlowEndToEndCCSource TruthValue,
|
|
juniAtmOamF4FlowEndToEndRowStatus RowStatus }
|
|
|
|
juniAtmOamF4FlowEndToEndIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface to configure the F4 OAM end-to-end
|
|
flow."
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 1 }
|
|
|
|
juniAtmOamF4FlowEndToEndVpi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the VPI for F4 OAM end-to-end flow configuration."
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 2 }
|
|
|
|
juniAtmOamF4FlowEndToEndLoopbackTimer OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configure the timer for sending the F4 flow end-to-end loopback OAM
|
|
cells. Setting this value will enable sending the F4 end cells on the
|
|
circuit. It is not allowed to set the value to -1 and whenever it is
|
|
read as -1 that means sending end loopback is not enabled. Setting the
|
|
loopback timer, other than -1, will enable sending the end cells."
|
|
DEFVAL { -1 }
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 3 }
|
|
|
|
juniAtmOamF4FlowEndToEndCCSink OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable F4 flow end-to-end continuity check sink end point for
|
|
this VP."
|
|
DEFVAL { false }
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 4 }
|
|
|
|
juniAtmOamF4FlowEndToEndCCSource OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable F4 flow end-to-end continuity check source end point for
|
|
this VP."
|
|
DEFVAL { false }
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 5 }
|
|
|
|
juniAtmOamF4FlowEndToEndRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create/delete an entry in this table, the following entry objects
|
|
MUST be explicitly configured:
|
|
juniAtmOamF4FlowEndToEndRowStatus
|
|
|
|
F4 OAM end loopback and CC tests are mutually exclusive, enabling one
|
|
will disable the other automatically. So, it is not allowed either at
|
|
the circuit creation time or after the circuit creation to issue a
|
|
request to enable end-to-end loopback and CC tests simultaneouly.
|
|
Enabling/disabling CC sink and source is one time operation. To
|
|
re-enable either CC source and sink in way different to earlier, both
|
|
has to be disabled from the previous."
|
|
::= { juniAtmOamF4FlowEndToEndCfgEntry 6 }
|
|
|
|
|
|
--
|
|
-- The juniAtmOamF4FlowSegmentConfigTable
|
|
--
|
|
juniAtmOamF4FlowSegmentCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmOamF4FlowSegmentCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for F4 OAM Segment flows configured."
|
|
::= { juniAtmIfLayer 9 }
|
|
|
|
juniAtmOamF4FlowSegmentCfgEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmOamF4FlowSegmentCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides configuration parameters for one F4 OAM Segment
|
|
flow configured for each VPI."
|
|
INDEX { juniAtmOamF4FlowSegmentIfIndex,
|
|
juniAtmOamF4FlowSegmentVpi }
|
|
::= { juniAtmOamF4FlowSegmentCfgTable 1 }
|
|
|
|
JuniAtmOamF4FlowSegmentCfgEntry ::= SEQUENCE {
|
|
juniAtmOamF4FlowSegmentIfIndex InterfaceIndex,
|
|
juniAtmOamF4FlowSegmentVpi Integer32,
|
|
juniAtmOamF4FlowSegmentCCSink TruthValue,
|
|
juniAtmOamF4FlowSegmentCCSource TruthValue,
|
|
juniAtmOamF4FlowSegmentRowStatus RowStatus }
|
|
|
|
juniAtmOamF4FlowSegmentIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface to configure the F4 OAM segment flow."
|
|
::= { juniAtmOamF4FlowSegmentCfgEntry 1 }
|
|
|
|
juniAtmOamF4FlowSegmentVpi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the VPI for F4 OAM segment flow configuration."
|
|
::= { juniAtmOamF4FlowSegmentCfgEntry 2 }
|
|
|
|
juniAtmOamF4FlowSegmentCCSink OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable F4 flow segment continuity check sink end point for
|
|
this VP."
|
|
DEFVAL { false }
|
|
::= { juniAtmOamF4FlowSegmentCfgEntry 3 }
|
|
|
|
juniAtmOamF4FlowSegmentCCSource OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable F4 flow segment continuity check source end point for
|
|
this VP."
|
|
DEFVAL { false }
|
|
::= { juniAtmOamF4FlowSegmentCfgEntry 4 }
|
|
|
|
juniAtmOamF4FlowSegmentRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create/delete an entry in this table, the following entry objects
|
|
MUST be explicitly configured:
|
|
juniAtmOamF4FlowSegmentRowStatus
|
|
|
|
Enabling/disabling CC sink and source is one time operation. To
|
|
re-enable either CC source and sink in way different to earlier, both
|
|
has to be disabled from the previous. F4 OAM segment loopback test is
|
|
not supported."
|
|
::= { juniAtmOamF4FlowSegmentCfgEntry 5 }
|
|
|
|
|
|
--
|
|
-- juniAtmVpDescrTable
|
|
--
|
|
juniAtmVpDescrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVpDescrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM VP Description present in the
|
|
system. The user can configure a description of up to 32 characters for
|
|
every VP in the ATM interface. A row exists for every VP on the ATM
|
|
interface. These rows get created as soon as the ATM major interface
|
|
created."
|
|
::= { juniAtmIfLayer 10 }
|
|
|
|
juniAtmVpDescrEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVpDescrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains the description of the VP."
|
|
INDEX { ifIndex,
|
|
atmVplVpi }
|
|
::= { juniAtmVpDescrTable 1 }
|
|
|
|
JuniAtmVpDescrEntry ::= SEQUENCE {
|
|
juniAtmVpDescription SnmpAdminString }
|
|
|
|
juniAtmVpDescription OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description for this VP. The default value of this object is null
|
|
string."
|
|
DEFVAL { "" }
|
|
::= { juniAtmVpDescrEntry 1 }
|
|
|
|
|
|
--
|
|
-- The juniAtmF4FlowOamEndToEndStatsTable
|
|
--
|
|
juniAtmF4FlowOamEndToEndStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmF4FlowOamEndToEndStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for F4 flow EndToEnd OAM circuits stats."
|
|
::= { juniAtmIfLayer 11 }
|
|
|
|
juniAtmF4FlowOamEndToEndStatsEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmF4FlowOamEndToEndStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides stats for one F4 OAM circuit for each VPI."
|
|
INDEX { juniAtmOamF4FlowEndToEndIfIndex,
|
|
juniAtmOamF4FlowEndToEndVpi }
|
|
::= { juniAtmF4FlowOamEndToEndStatsTable 1 }
|
|
|
|
JuniAtmF4FlowOamEndToEndStatsEntry ::= SEQUENCE {
|
|
juniAtmF4FlowInOamEndAisCells Counter32,
|
|
juniAtmF4FlowInOamEndRdiCells Counter32,
|
|
juniAtmF4FlowInOamEndCCCells Counter32,
|
|
juniAtmF4FlowInOamEndCCActDeActCells Counter32,
|
|
juniAtmF4FlowInOamEndLoopbackCells Counter32,
|
|
juniAtmF4FlowOutEndRdiCells Counter32,
|
|
juniAtmF4FlowOutEndCCCells Counter32,
|
|
juniAtmF4FlowOutEndCCActDeActCells Counter32,
|
|
juniAtmF4FlowOutEndToEndLoopbackCells Counter32,
|
|
juniAtmF4FlowEndActualLoopbackFreq Integer32,
|
|
juniAtmF4FlowEndLastTimeChanged TimeTicks,
|
|
juniAtmF4FlowOamEndVpOperationState INTEGER,
|
|
juniAtmF4FlowOamEndVpAdminState INTEGER,
|
|
juniAtmF4FlowEndInOamCells Counter32,
|
|
juniAtmF4FlowEndOutOamCells Counter32,
|
|
juniAtmF4FlowEndInOamCellsDropped Counter32,
|
|
juniAtmF4FlowEndToEndInLoopbackCmds Counter32,
|
|
juniAtmF4FlowEndToEndInLoopbackRsps Counter32,
|
|
juniAtmF4FlowEndToEndOutLoopbackCmds Counter32,
|
|
juniAtmF4FlowEndToEndOutLoopbackRsps Counter32 }
|
|
|
|
juniAtmF4FlowInOamEndAisCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 AIS cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 1 }
|
|
|
|
juniAtmF4FlowInOamEndRdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 RDI cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 2 }
|
|
|
|
juniAtmF4FlowInOamEndCCCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 CC cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 3 }
|
|
|
|
juniAtmF4FlowInOamEndCCActDeActCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 activation/de-activation cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 4 }
|
|
|
|
juniAtmF4FlowInOamEndLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total received OAM F4 end-to-end loopback cells. Aggregate of
|
|
juniAtmF4FlowEndToEndInLoopbackCmds and
|
|
juniAtmF4FlowEndToEndInLoopbackRsps"
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 5 }
|
|
|
|
juniAtmF4FlowOutEndRdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 RDI cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 6 }
|
|
|
|
juniAtmF4FlowOutEndCCCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 CC cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 7 }
|
|
|
|
juniAtmF4FlowOutEndCCActDeActCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 activation/de-activation cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 8 }
|
|
|
|
juniAtmF4FlowOutEndToEndLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total transmitted OAM F4 end-to-end loopback cells. Aggregate of
|
|
juniAtmF4FlowEndToEndOutLoopbackCmds and
|
|
juniAtmF4FlowEndToEndOutLoopbackRsps"
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 9 }
|
|
|
|
juniAtmF4FlowEndActualLoopbackFreq OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual end-to-end loopback Frequecy calculated for OAM cells
|
|
transmission."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 10 }
|
|
|
|
juniAtmF4FlowEndLastTimeChanged OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last time end-to-end F4 OAM flow got changed."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 11 }
|
|
|
|
juniAtmF4FlowOamEndVpOperationState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vcAisState(0),
|
|
vcRdiState(1),
|
|
vcDownRetry(2),
|
|
vcUpRetry(3),
|
|
vcUp(4),
|
|
vcDown(5),
|
|
vcNotManaged(6),
|
|
vpAisState(7),
|
|
vpRdiState(8),
|
|
vcInVpRdiState(9),
|
|
vcInVpAisState(10),
|
|
vcSegmentAisState(11),
|
|
vcSegRdiState(12) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the F4 end-to-end OAM flow VP operation states. It can take
|
|
one of the following operational state values:
|
|
vcAisState - AIS cell received or underlying physical layer
|
|
reporting transmission path AIS.
|
|
vcRdiState - RDI cell received.
|
|
vcDownRetry - OAM loopback failed, using retry frequency to
|
|
verify that the VC is really down.
|
|
vcUpRetry - OAM loopback successful, using retry frequency
|
|
to verify that the VC is really up.
|
|
vcUp - OAM loopback successful after up retry
|
|
verification.
|
|
vcDown - OAM loopback failed after down retry
|
|
verification.
|
|
vcNotManaged - No verification via loopback cells being
|
|
performed.
|
|
vpAisState - State when F4 AIS cell is received.
|
|
vpRdiState - State when F4 RDI cell is received.
|
|
vcInVpRdiState - The data vc is down as a result of VP failure
|
|
thorugh F4 Rdi oam cell.
|
|
vcInVpAisState - The data vc is down as a result of VP failure
|
|
through F4 Ais oam cell.
|
|
vcSegmentAisState - Segment AIS cell received.
|
|
vcSegRdiState - Segment RDI cell received."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 12 }
|
|
|
|
juniAtmF4FlowOamEndVpAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End-to-end VP admin state."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 13 }
|
|
|
|
juniAtmF4FlowEndInOamCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 loopback cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 14 }
|
|
|
|
juniAtmF4FlowEndOutOamCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 loopback cells."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 15 }
|
|
|
|
juniAtmF4FlowEndInOamCellsDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM cells that were dropped."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 16 }
|
|
|
|
juniAtmF4FlowEndToEndInLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F4 end-to-end loopback commands."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 17 }
|
|
|
|
juniAtmF4FlowEndToEndInLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F4 end-to-end loopback responses."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 18 }
|
|
|
|
juniAtmF4FlowEndToEndOutLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F4 end-to-end loopback commands."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 19 }
|
|
|
|
juniAtmF4FlowEndToEndOutLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F4 end-to-end loopback responses."
|
|
::= { juniAtmF4FlowOamEndToEndStatsEntry 20 }
|
|
|
|
|
|
--
|
|
-- The juniAtmF4FlowOamSegmentStatsTable
|
|
--
|
|
juniAtmF4FlowOamSegmentStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmF4FlowOamSegmentStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for F4 flow Segment OAM circuits stats."
|
|
::= { juniAtmIfLayer 12 }
|
|
|
|
juniAtmF4FlowOamSegmentStatsEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmF4FlowOamSegmentStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides stats for one F4 OAM circuit for each VPI."
|
|
INDEX { juniAtmOamF4FlowSegmentIfIndex,
|
|
juniAtmOamF4FlowSegmentVpi }
|
|
::= { juniAtmF4FlowOamSegmentStatsTable 1 }
|
|
|
|
JuniAtmF4FlowOamSegmentStatsEntry ::= SEQUENCE {
|
|
juniAtmF4FlowInOamSegmentAisCells Counter32,
|
|
juniAtmF4FlowInOamSegmentRdiCells Counter32,
|
|
juniAtmF4FlowInOamSegmentCCCells Counter32,
|
|
juniAtmF4FlowInOamSegmentCCActDeActCells Counter32,
|
|
juniAtmF4FlowInOamSegmentLoopbackCells Counter32,
|
|
juniAtmF4FlowOutSegmentRdiCells Counter32,
|
|
juniAtmF4FlowOutSegmentCCCells Counter32,
|
|
juniAtmF4FlowOutSegmentCCActDeActCells Counter32,
|
|
juniAtmF4FlowOutSegmentLoopbackCells Counter32,
|
|
juniAtmF4FlowSegmentLastTimeChanged TimeTicks,
|
|
juniAtmF4FlowOamSegmentVpOperationState INTEGER,
|
|
juniAtmF4FlowOamSegmentVpAdminState INTEGER,
|
|
juniAtmF4FlowSegmentInOamCells Counter32,
|
|
juniAtmF4FlowSegmentOutOamCells Counter32,
|
|
juniAtmF4FlowSegmentInOamCellsDropped Counter32,
|
|
juniAtmF4FlowSegmentInLoopbackCmds Counter32,
|
|
juniAtmF4FlowSegmentInLoopbackRsps Counter32,
|
|
juniAtmF4FlowSegmentOutLoopbackCmds Counter32,
|
|
juniAtmF4FlowSegmentOutLoopbackRsps Counter32 }
|
|
|
|
juniAtmF4FlowInOamSegmentAisCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 AIS cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 1 }
|
|
|
|
juniAtmF4FlowInOamSegmentRdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 RDI cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 2 }
|
|
|
|
juniAtmF4FlowInOamSegmentCCCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 CC cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 3 }
|
|
|
|
juniAtmF4FlowInOamSegmentCCActDeActCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 activation/de-activation cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 4 }
|
|
|
|
juniAtmF4FlowInOamSegmentLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total received OAM F4 segment loopback cells. Aggregate of
|
|
juniAtmF4FlowSegmentInLoopbackCmds and
|
|
juniAtmF4FlowSegmentInLoopbackRsps"
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 5 }
|
|
|
|
juniAtmF4FlowOutSegmentRdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 RDI cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 6 }
|
|
|
|
juniAtmF4FlowOutSegmentCCCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 CC cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 7 }
|
|
|
|
juniAtmF4FlowOutSegmentCCActDeActCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 activation/de-activation cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 8 }
|
|
|
|
juniAtmF4FlowOutSegmentLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total transmitted OAM F4 segment loopback cells. Aggregate of
|
|
juniAtmF4FlowSegmentOutLoopbackCmds and
|
|
juniAtmF4FlowSegmentOutLoopbackRsps"
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 9 }
|
|
|
|
juniAtmF4FlowSegmentLastTimeChanged OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last time end-to-end F4 OAM flow got changed."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 10 }
|
|
|
|
juniAtmF4FlowOamSegmentVpOperationState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
vcAisState(0),
|
|
vcRdiState(1),
|
|
vcDownRetry(2),
|
|
vcUpRetry(3),
|
|
vcUp(4),
|
|
vcDown(5),
|
|
vcNotManaged(6),
|
|
vpAisState(7),
|
|
vpRdiState(8),
|
|
vcInVpRdiState(9),
|
|
vcInVpAisState(10),
|
|
vcSegmentAisState(11),
|
|
vcSegRdiState(12) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the F4 end-to-end OAM flow VP operation states. It can take
|
|
one of the following operational state values:
|
|
vcAisState - AIS cell received or underlying physical layer
|
|
reporting transmission path AIS.
|
|
vcRdiState - RDI cell received.
|
|
vcDownRetry - OAM loopback failed, using retry frequency to
|
|
verify that the VC is really down.
|
|
vcUpRetry - OAM loopback successful, using retry frequency
|
|
to verify that the VC is really up.
|
|
vcUp - OAM loopback successful after up retry
|
|
verification.
|
|
vcDown - OAM loopback failed after down retry
|
|
verification.
|
|
vcNotManaged - No verification via loopback cells being
|
|
performed.
|
|
vpAisState - State when F4 AIS cell is received.
|
|
vpRdiState - State when F4 RDI cell is received.
|
|
vcInVpRdiState - The data vc is down as a result of VP failure
|
|
thorugh F4 Rdi oam cell.
|
|
vcInVpAisState - The data vc is down as a result of VP failure
|
|
through F4 Ais oam cell.
|
|
vcSegmentAisState - Segment AIS cell received.
|
|
vcSegRdiState - Segment RDI cell received."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 11 }
|
|
|
|
juniAtmF4FlowOamSegmentVpAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
up(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Segment VP admin state."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 12 }
|
|
|
|
juniAtmF4FlowSegmentInOamCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM F4 loopback cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 13 }
|
|
|
|
juniAtmF4FlowSegmentOutOamCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted end-to-end OAM F4 loopback cells."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 14 }
|
|
|
|
juniAtmF4FlowSegmentInOamCellsDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received end-to-end OAM cells that were dropped."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 15 }
|
|
|
|
juniAtmF4FlowSegmentInLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F4 segment loopback commands."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 16 }
|
|
|
|
juniAtmF4FlowSegmentInLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F4 segment loopback responses."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 17 }
|
|
|
|
juniAtmF4FlowSegmentOutLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F4 segment loopback commands."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 18 }
|
|
|
|
juniAtmF4FlowSegmentOutLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F4 segment loopback responses."
|
|
::= { juniAtmF4FlowOamSegmentStatsEntry 19 }
|
|
|
|
|
|
--
|
|
-- juniAtmMartiniTimeoutTimerTable
|
|
--
|
|
juniAtmMartiniTimeoutTimerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmMartiniTimeoutTimerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM Martini cell aggregation timeout
|
|
detection. The user can configure timeout values for three timers.
|
|
A row exists for every separate timer supported. These rows get
|
|
created as soon as the ERX system comes up."
|
|
::= { juniAtmIfLayer 13 }
|
|
|
|
juniAtmMartiniTimeoutTimerEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmMartiniTimeoutTimerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains the timeout value of ATM Martini
|
|
cell aggregation timer."
|
|
INDEX { juniAtmMartiniTimeoutTimerIndex }
|
|
::= { juniAtmMartiniTimeoutTimerTable 1 }
|
|
|
|
JuniAtmMartiniTimeoutTimerEntry ::= SEQUENCE {
|
|
juniAtmMartiniTimeoutTimerIndex INTEGER,
|
|
juniAtmMartiniTimeoutTimerValue Integer32 }
|
|
|
|
juniAtmMartiniTimeoutTimerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
timer1(1),
|
|
timer2(2),
|
|
timer3(3) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Martini cell aggregation timeout timer identifier."
|
|
::= { juniAtmMartiniTimeoutTimerEntry 1 }
|
|
|
|
juniAtmMartiniTimeoutTimerValue OBJECT-TYPE
|
|
SYNTAX Integer32 (100..4095)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM Martini cell aggregation timeout timer value in microseconds."
|
|
DEFVAL { 100 }
|
|
::= { juniAtmMartiniTimeoutTimerEntry 2 }
|
|
|
|
-- ///////////////////
|
|
-- ATM VP Statistics
|
|
--
|
|
-- //////////////////
|
|
--
|
|
-- juniAtmVpStatsTable
|
|
--
|
|
juniAtmVpStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVpStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM VP statistics present in the
|
|
system. A row exists for every VP on the ATM
|
|
interface. These rows get created as soon as the ATM major interface
|
|
created."
|
|
::= { juniAtmIfLayer 14 }
|
|
|
|
juniAtmVpStatsEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVpStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contain the VP statistics."
|
|
INDEX { ifIndex,
|
|
atmVplVpi }
|
|
::= { juniAtmVpStatsTable 1 }
|
|
|
|
JuniAtmVpStatsEntry ::= SEQUENCE {
|
|
juniAtmVpStatsIfIndex InterfaceIndex,
|
|
juniAtmVpStatsVpi AtmVpIdentifier,
|
|
juniAtmVpStatsInCells Counter64,
|
|
juniAtmVpStatsInPackets Counter64,
|
|
juniAtmVpStatsInPacketOctets Counter64,
|
|
juniAtmVpStatsOutCells Counter64,
|
|
juniAtmVpStatsOutPackets Counter64,
|
|
juniAtmVpStatsOutPacketOctets Counter64,
|
|
juniAtmVpStatsInPacketErrors Counter32,
|
|
juniAtmVpStatsOutPacketErrors Counter32,
|
|
juniAtmVpStatsInPacketDiscards Counter32,
|
|
juniAtmVpStatsInPacketOctetDiscards Counter32,
|
|
juniAtmVpStatsInPacketUnknownProtocol Counter32,
|
|
juniAtmVpStatsCrcErrors Counter32,
|
|
juniAtmVpStatsSarTimeouts Counter32,
|
|
juniAtmVpStatsOverSizedPackets Counter32
|
|
}
|
|
|
|
juniAtmVpStatsIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM interface."
|
|
::= { juniAtmVpStatsEntry 1 }
|
|
|
|
juniAtmVpStatsVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI value of the virtual path for which statistics are retrieved."
|
|
::= { juniAtmVpStatsEntry 2 }
|
|
|
|
|
|
juniAtmVpStatsInCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received cells."
|
|
::= { juniAtmVpStatsEntry 3 }
|
|
|
|
juniAtmVpStatsInPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received AAL5 PDUs."
|
|
::= { juniAtmVpStatsEntry 4 }
|
|
|
|
juniAtmVpStatsInPacketOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received AAL5 PDU octets."
|
|
::= { juniAtmVpStatsEntry 5 }
|
|
|
|
juniAtmVpStatsOutCells OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted cells."
|
|
::= { juniAtmVpStatsEntry 6 }
|
|
|
|
juniAtmVpStatsOutPackets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted AAL5 PDUs"
|
|
::= { juniAtmVpStatsEntry 7 }
|
|
|
|
juniAtmVpStatsOutPacketOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted AAL5 PDU octets."
|
|
::= { juniAtmVpStatsEntry 8 }
|
|
|
|
juniAtmVpStatsInPacketErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets dropped due to errors."
|
|
::= { juniAtmVpStatsEntry 9 }
|
|
|
|
|
|
juniAtmVpStatsOutPacketErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Packets not transmitted due to errors."
|
|
::= { juniAtmVpStatsEntry 10 }
|
|
juniAtmVpStatsInPacketDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets without errors discarded."
|
|
::= { juniAtmVpStatsEntry 11 }
|
|
|
|
juniAtmVpStatsInPacketOctetDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received bytes without errors discarded."
|
|
::= { juniAtmVpStatsEntry 12 }
|
|
|
|
juniAtmVpStatsInPacketUnknownProtocol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets that are discarded because the interface can not
|
|
discern or is not configured to support this protocol."
|
|
::= { juniAtmVpStatsEntry 13 }
|
|
|
|
juniAtmVpStatsCrcErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets that are discarded because of check sum erros"
|
|
::= { juniAtmVpStatsEntry 14 }
|
|
|
|
juniAtmVpStatsSarTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received packets that are discarded because of SAR timeout"
|
|
::= { juniAtmVpStatsEntry 15 }
|
|
|
|
juniAtmVpStatsOverSizedPackets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Over sized packets that are received on this VP."
|
|
::= { juniAtmVpStatsEntry 16 }
|
|
|
|
|
|
|
|
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- AAL5 LAYER
|
|
--
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- IfIndex selection for creating new ATM AAL5 interfaces
|
|
--
|
|
juniAtmAal5NextIfIndex OBJECT-TYPE
|
|
SYNTAX JuniNextIfIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Coordinate ifIndex value allocation for entries in juniAtmAal5IfTable.
|
|
|
|
A GET of this object returns the next available ifIndex value to be used
|
|
to create an entry in the associated interface table; or zero, if no
|
|
valid ifIndex value is available. This object also returns a value of
|
|
zero when it is the lexicographic successor of a varbind presented in an
|
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
|
that ifIndex allocation is unintended.
|
|
|
|
Successive GETs will typically return different values, thus avoiding
|
|
collisions among cooperating management clients seeking to create table
|
|
entries simultaneously."
|
|
::= { juniAtmAal5IfLayer 1 }
|
|
|
|
|
|
--
|
|
-- The ATM AAL5 Interface Table
|
|
--
|
|
juniAtmAal5IfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmAal5IfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM AAL5 interfaces present in the
|
|
system."
|
|
::= { juniAtmAal5IfLayer 2 }
|
|
|
|
juniAtmAal5IfEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmAal5IfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM AAL5 interface.
|
|
Creating/deleting entries in this table causes corresponding entries for
|
|
be created/deleted in ifTable/ifXTable/juniIfTable."
|
|
INDEX { juniAtmAal5IfIndex }
|
|
::= { juniAtmAal5IfTable 1 }
|
|
|
|
JuniAtmAal5IfEntry ::= SEQUENCE {
|
|
juniAtmAal5IfIndex InterfaceIndex,
|
|
juniAtmAal5IfRowStatus RowStatus,
|
|
juniAtmAal5IfLowerIfIndex InterfaceIndexOrZero }
|
|
|
|
juniAtmAal5IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM AAL5 interface. When creating entries in this
|
|
table, suitable values for this object are determined by reading
|
|
juniAtmAal5NextIfIndex."
|
|
::= { juniAtmAal5IfEntry 1 }
|
|
|
|
juniAtmAal5IfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create an entry in this table, the following entry objects MUST be
|
|
explicitly configured:
|
|
juniAtmAal5IfRowStatus
|
|
juniAtmAal5IfLowerIfIndex
|
|
|
|
In addition, when creating an entry the following condition must hold:
|
|
A value for juniAtmAal5IfIndex must have been determined previously,
|
|
by reading juniAtmAal5NextIfIndex.
|
|
|
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
|
|
destroyed as a result of creating/destroying an entry in this table."
|
|
::= { juniAtmAal5IfEntry 2 }
|
|
|
|
juniAtmAal5IfLowerIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of an ATM interface over which this ATM AAL5 interface is
|
|
to be layered. A value of zero indicates no layering. An
|
|
implementation may choose to require that a nonzero value be configured
|
|
at entry creation."
|
|
::= { juniAtmAal5IfEntry 3 }
|
|
|
|
|
|
--
|
|
-- ATM Bulk Circuites Name Table
|
|
--
|
|
juniAtmBulkCircuitsNameTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries in this table provide mappings of ATM bulk virtual circuit
|
|
range names to local integer identifiers for those profiles. These
|
|
integers are used as indexes into other MIB tables containing profile
|
|
configuration parameters associated with the same profile name."
|
|
::= { juniAtmAal5IfLayer 3 }
|
|
|
|
juniAtmBulkCircuitsNameEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmBulkCircuitsNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mapping of a ATM bulk virtual circuit range name to an integer
|
|
identifier for that name."
|
|
INDEX { juniAtmBulkCircuitsNameAal5IfIndex,
|
|
juniAtmBulkCircuitsNameName }
|
|
::= { juniAtmBulkCircuitsNameTable 1 }
|
|
|
|
JuniAtmBulkCircuitsNameEntry ::= SEQUENCE {
|
|
juniAtmBulkCircuitsNameAal5IfIndex InterfaceIndex,
|
|
juniAtmBulkCircuitsNameName DisplayString,
|
|
juniAtmBulkCircuitsNameRowStatus RowStatus,
|
|
juniAtmBulkCircuitsNameId Unsigned32 }
|
|
|
|
juniAtmBulkCircuitsNameAal5IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM AAL5 interface."
|
|
::= { juniAtmBulkCircuitsNameEntry 1 }
|
|
|
|
juniAtmBulkCircuitsNameName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..80))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM bulk virtual circuit range name uniquely identifying this
|
|
entry."
|
|
::= { juniAtmBulkCircuitsNameEntry 2 }
|
|
|
|
juniAtmBulkCircuitsNameRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table. Only the values
|
|
'createAndGo' and 'destroy' may be SET.
|
|
|
|
Creating an entry in this table creates corresponding entry in
|
|
juniAtmBulkCircuitsIdTable. Deleting an entry in this table deletes
|
|
corresponding entries in juniAtmBulkCircuitsIdTable,
|
|
juniAtmBulkCircuitsTable and
|
|
juniAtmProfileOverrideAssignIfCircuitTable."
|
|
::= { juniAtmBulkCircuitsNameEntry 3 }
|
|
|
|
juniAtmBulkCircuitsNameId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this ATM bulk virtual circuit
|
|
range name.
|
|
|
|
This value of this identifier is assigned by the device when an entry in
|
|
this table is created."
|
|
::= { juniAtmBulkCircuitsNameEntry 4 }
|
|
|
|
|
|
--
|
|
-- ATM Bulk Circuits ID Table
|
|
--
|
|
juniAtmBulkCircuitsIdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides inverse mapping of ATM bulk virtual circuit IDs to ATM bulk
|
|
virtual circuit names."
|
|
::= { juniAtmAal5IfLayer 4 }
|
|
|
|
juniAtmBulkCircuitsIdEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmBulkCircuitsIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mapping of an integer identifier to a ATM bulk virtual circuit name."
|
|
INDEX { juniAtmBulkCircuitsIdAal5IfIndex,
|
|
juniAtmBulkCircuitsIdId }
|
|
::= { juniAtmBulkCircuitsIdTable 1 }
|
|
|
|
JuniAtmBulkCircuitsIdEntry ::= SEQUENCE {
|
|
juniAtmBulkCircuitsIdAal5IfIndex InterfaceIndex,
|
|
juniAtmBulkCircuitsIdId Unsigned32,
|
|
juniAtmBulkCircuitsIdName DisplayString,
|
|
juniAtmBulkCircuitsIdNextInstance Unsigned32 }
|
|
|
|
juniAtmBulkCircuitsIdAal5IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM AAL5 interface."
|
|
::= { juniAtmBulkCircuitsIdEntry 1 }
|
|
|
|
juniAtmBulkCircuitsIdId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this ATM bulk virtual circuit
|
|
name."
|
|
::= { juniAtmBulkCircuitsIdEntry 2 }
|
|
|
|
juniAtmBulkCircuitsIdName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM bulk virtual circuit name having the associated identifier."
|
|
::= { juniAtmBulkCircuitsIdEntry 3 }
|
|
|
|
juniAtmBulkCircuitsIdNextInstance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The next available instance value for juniAtmBulkCircuitsEntry."
|
|
::= { juniAtmBulkCircuitsIdEntry 4 }
|
|
|
|
|
|
--
|
|
-- ATM Bulk Circuits Table
|
|
--
|
|
juniAtmBulkCircuitsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmBulkCircuitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains bulk virtual circuit range parameters."
|
|
::= { juniAtmAal5IfLayer 5 }
|
|
|
|
juniAtmBulkCircuitsEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmBulkCircuitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of VC range."
|
|
INDEX { juniAtmBulkCircuitsAal5IfIndex,
|
|
juniAtmBulkCircuitsId,
|
|
juniAtmBulkCircuitsInstance }
|
|
::= { juniAtmBulkCircuitsTable 1 }
|
|
|
|
JuniAtmBulkCircuitsEntry ::= SEQUENCE {
|
|
juniAtmBulkCircuitsAal5IfIndex InterfaceIndex,
|
|
juniAtmBulkCircuitsId Unsigned32,
|
|
juniAtmBulkCircuitsInstance Unsigned32,
|
|
juniAtmBulkCircuitsRowStatus RowStatus,
|
|
juniAtmBulkCircuitsMinVpi AtmVpIdentifier,
|
|
juniAtmBulkCircuitsMaxVpi AtmVpIdentifier,
|
|
juniAtmBulkCircuitsMinVci AtmVcIdentifier,
|
|
juniAtmBulkCircuitsMaxVci AtmVcIdentifier,
|
|
juniAtmBulkCircuitsAdminState JuniEnable }
|
|
|
|
juniAtmBulkCircuitsAal5IfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM AAL5 interface on which this bulk virtual
|
|
circuit sub-range is created."
|
|
::= { juniAtmBulkCircuitsEntry 1 }
|
|
|
|
juniAtmBulkCircuitsId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this ATM bulk virtual circuit
|
|
name."
|
|
::= { juniAtmBulkCircuitsEntry 2 }
|
|
|
|
juniAtmBulkCircuitsInstance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique identifier of the ATM bulk virtual circuit sub-range."
|
|
::= { juniAtmBulkCircuitsEntry 3 }
|
|
|
|
juniAtmBulkCircuitsRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table. Only the values
|
|
'createAndGo' and 'destroy' may be SET.
|
|
|
|
Since none of the VPI/VCI minimum and maximum values have default
|
|
values, all these values must be specified before setting RowStatus to
|
|
'createAndGo'. The VPI/VCI minimum and maximum values can only be
|
|
configured upon creation.
|
|
|
|
Deleting an entry in this table deletes corresponding entries in
|
|
juniAtmProfileOverrideAssignIfCircuitTable."
|
|
::= { juniAtmBulkCircuitsEntry 4 }
|
|
|
|
juniAtmBulkCircuitsMinVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum value of VPI for this circuit sub-range. This value must
|
|
be less than or equal to the value of juniAtmBulkCircuitsMaxVpi."
|
|
::= { juniAtmBulkCircuitsEntry 5 }
|
|
|
|
juniAtmBulkCircuitsMaxVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum value of VPI for this cicuit sub-range. This value must
|
|
be equal to or greater than the value of juniAtmBulkCircuitsMinVpi."
|
|
::= { juniAtmBulkCircuitsEntry 6 }
|
|
|
|
juniAtmBulkCircuitsMinVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum value of VCI for this circuit sub-range. This value must
|
|
be less than or equal to the value of juniAtmBulkCircuitsMaxVci."
|
|
::= { juniAtmBulkCircuitsEntry 7 }
|
|
|
|
juniAtmBulkCircuitsMaxVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum value of VCI for this circuit sub-range. This value must
|
|
be equal to or greater than the value of juniAtmBulkCircuitsMinVci."
|
|
::= { juniAtmBulkCircuitsEntry 8 }
|
|
|
|
juniAtmBulkCircuitsAdminState OBJECT-TYPE
|
|
SYNTAX JuniEnable
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative status of this circuit sub-range."
|
|
DEFVAL { enable }
|
|
::= { juniAtmBulkCircuitsEntry 9 }
|
|
|
|
|
|
|
|
--
|
|
-- Assign overriding profile to interface/vpi/vci.
|
|
--
|
|
juniAtmProfileOverrideAssignIfCircuitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmProfileOverrideAssignIfCircuitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table providing overriding profile assignment to a circuit configured
|
|
as part of bulk-configuration. Circuit is identified by interface index
|
|
and vpi, vci.
|
|
|
|
The entries in this table specify which profile to use when creating and
|
|
configuring a dynamic interface above a circuit specified by vpi and
|
|
vci.
|
|
|
|
This entry is effective when the circuit specified by
|
|
juniAtmProfileOverrideAssignIfCircuitAal5Index,
|
|
juniAtmProfileOverrideAssignIfCircuitRangeId,
|
|
juniAtmProfileOverrideAssignIfCircuitVpi,
|
|
juniAtmProfileOverrideAssignIfCircuitVci
|
|
is part of bulk-configuration."
|
|
::= { juniAtmAal5IfLayer 6 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmProfileOverrideAssignIfCircuitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An assignment of a profile to a circuit configured as part of
|
|
bulk-configuration on an AAL5 interface."
|
|
INDEX { juniAtmProfileOverrideAssignIfCircuitAal5Index,
|
|
juniAtmProfileOverrideAssignIfCircuitRangeId,
|
|
juniAtmProfileOverrideAssignIfCircuitVpi,
|
|
juniAtmProfileOverrideAssignIfCircuitVci }
|
|
::= { juniAtmProfileOverrideAssignIfCircuitTable 1 }
|
|
|
|
JuniAtmProfileOverrideAssignIfCircuitEntry ::= SEQUENCE {
|
|
juniAtmProfileOverrideAssignIfCircuitAal5Index InterfaceIndex,
|
|
juniAtmProfileOverrideAssignIfCircuitRangeId Unsigned32,
|
|
juniAtmProfileOverrideAssignIfCircuitVpi AtmVpIdentifier,
|
|
juniAtmProfileOverrideAssignIfCircuitVci AtmVcIdentifier,
|
|
juniAtmProfileOverrideAssignIfCircuitRowStatus RowStatus,
|
|
juniAtmProfileOverrideAssignIfCircuitProfileId Unsigned32,
|
|
juniAtmProfileOverrideAssignIfCircuitOperStatus INTEGER }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitAal5Index OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the AAL5 interface to which the profile is assigned."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 1 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitRangeId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with the ATM bulk circuit
|
|
configuration."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 2 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI value of the circuit to which the profile is assigned."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 3 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI value of the circuit to which the profile is assigned."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 4 }
|
|
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table. Only the values
|
|
'createAndGo' and 'destroy' may be SET.
|
|
|
|
Since the VPI, VCI and profileId values do not have any default
|
|
values, all these values must be specified before setting RowStatus to
|
|
'createAndGo'. The VPI, VCI and profileId values can only be
|
|
configured upon creation. None of these values can be modified except
|
|
by deleting the entry."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 5 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitProfileId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of the profile assigned to the circuit configured as part of
|
|
bulk-configuration. Circuit is identified by interface index and vpi,
|
|
vci."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 6 }
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inactive(0),
|
|
active(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational status of the profile override assignment identified
|
|
by this entry.
|
|
|
|
It returns inactive(0), if a static ATM circuit with identical VPI/VCI
|
|
values is present on the same ATM interface. In this case, this
|
|
profile override will not be used to configure upper dynamic
|
|
interfaces.
|
|
|
|
It returns active(1), if no static ATM circuit with identical VPI/VCI
|
|
values is present on the same ATM interface. In this case, this
|
|
profile override will be used to configure upper dynamic interfaces."
|
|
::= { juniAtmProfileOverrideAssignIfCircuitEntry 7 }
|
|
|
|
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- ATM SUBINTERFACE LAYER
|
|
--
|
|
-- /////////////////////////////////////////////////////////////////////////////
|
|
--
|
|
-- IfIndex selection for creating new ATM Subinterfaces
|
|
--
|
|
juniAtmSubIfNextIfIndex OBJECT-TYPE
|
|
SYNTAX JuniNextIfIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Coordinate ifIndex value allocation for entries in juniAtmSubIfTable.
|
|
|
|
A GET of this object returns the next available ifIndex value to be used
|
|
to create an entry in the associated interface table; or zero, if no
|
|
valid ifIndex value is available. This object also returns a value of
|
|
zero when it is the lexicographic successor of a varbind presented in an
|
|
SNMP GETNEXT or GETBULK request, for which circumstance it is assumed
|
|
that ifIndex allocation is unintended.
|
|
|
|
Successive GETs will typically return different values, thus avoiding
|
|
collisions among cooperating management clients seeking to create table
|
|
entries simultaneously."
|
|
::= { juniAtmSubIfLayer 1 }
|
|
|
|
--
|
|
-- The ATM Subinterface Table
|
|
--
|
|
juniAtmSubIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmSubIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM Subinterfaces present in the
|
|
system."
|
|
::= { juniAtmSubIfLayer 2 }
|
|
|
|
juniAtmSubIfEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmSubIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM Subinterface.
|
|
Creating/deleting entries in this table causes corresponding entries for
|
|
be created/deleted in ifTable/ifXTable/juniIfTable."
|
|
INDEX { juniAtmSubIfIndex }
|
|
::= { juniAtmSubIfTable 1 }
|
|
|
|
JuniAtmSubIfEntry ::= SEQUENCE {
|
|
juniAtmSubIfIndex InterfaceIndex,
|
|
juniAtmSubIfRowStatus RowStatus,
|
|
juniAtmSubIfDistinguisher Integer32,
|
|
juniAtmSubIfLowerIfIndex InterfaceIndexOrZero,
|
|
juniAtmSubIfNbma TruthValue,
|
|
juniAtmSubIfAddress AtmAddr,
|
|
juniAtmSubIfMtu Integer32,
|
|
juniAtmSubIfAdvisoryRxSpeed Integer32,
|
|
juniAtmSubIfMartiniMaxCellsPerPacket Integer32,
|
|
juniAtmSubIfMartiniTimeoutTimerId Integer32,
|
|
juniAtmSubIfAssociatedVcClassId Unsigned32
|
|
}
|
|
|
|
juniAtmSubIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM Subinterface. When creating entries in this
|
|
table, suitable values for this object are determined by reading
|
|
juniAtmSubNextIfIndex."
|
|
::= { juniAtmSubIfEntry 1 }
|
|
|
|
juniAtmSubIfRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create an entry in this table, the following entry objects MUST be
|
|
explicitly configured:
|
|
juniAtmSubIfRowStatus
|
|
juniAtmSubIfLowerIndex
|
|
|
|
In addition, when creating an entry the following condition must hold:
|
|
A value for juniAtmSubIfIndex must have been determined previously,
|
|
by reading juniAtmSubIfNextIfIndex.
|
|
|
|
A corresponding entry in ifTable/ifXTable/juniIfTable is created or
|
|
destroyed as a result of creating/destroying an entry in this table."
|
|
::= { juniAtmSubIfEntry 2 }
|
|
|
|
juniAtmSubIfDistinguisher OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer identifier for the subinterface, used in conjunction with
|
|
the command-line interface. It is provided here for cross-reference
|
|
purposes only.
|
|
|
|
The value must be unique among subinterfaces configured on the same
|
|
underlying ATM adaptation layer. The upper bound for the value is
|
|
further constrained to be identical with the maximum number of
|
|
subinterfaces supported by the lower interface.
|
|
|
|
If this object is not configured, a value will be allocated internally
|
|
and can be queried after table entry creation has succeeded."
|
|
::= { juniAtmSubIfEntry 3 }
|
|
|
|
juniAtmSubIfLowerIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of an ATM AAL5 interface over which this ATM subinterface
|
|
is to be layered. A value of zero indicates no layering. An
|
|
implementation may choose to require that a nonzero value be configured
|
|
at entry creation."
|
|
::= { juniAtmSubIfEntry 4 }
|
|
|
|
juniAtmSubIfNbma OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NBMA administrative setting. Setting this value of this object to
|
|
true(1) will enable multipoint access on this interface. Setting the
|
|
value to false(2), will enable point to point access on this interface."
|
|
DEFVAL { false }
|
|
::= { juniAtmSubIfEntry 5 }
|
|
|
|
juniAtmSubIfAddress OBJECT-TYPE
|
|
SYNTAX AtmAddr (SIZE(0|7|20))
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the local ATM NSAP address of the circuit. A GET operation
|
|
returns a full 20-octet NSAP. A SET operation only requires 7 octets,
|
|
since the prefix can be implied."
|
|
DEFVAL { ''H }
|
|
::= { juniAtmSubIfEntry 6 }
|
|
|
|
juniAtmSubIfMtu OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the largest packet which can be sent/received on the
|
|
interface, specified in octets."
|
|
DEFVAL { 9180 }
|
|
::= { juniAtmSubIfEntry 7 }
|
|
|
|
juniAtmSubIfAdvisoryRxSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Advisory receive speed, in kilobits per second (kbps),
|
|
of this subinterface. This object has no impact on
|
|
forwarding performance but may be used as a hint for
|
|
underlying circuit receive speed."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfEntry 8 }
|
|
|
|
juniAtmSubIfMartiniMaxCellsPerPacket OBJECT-TYPE
|
|
SYNTAX Integer32 (1..190)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of cells that can be aggregated in a single ATM Martini
|
|
packet in cell-relay mode."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmSubIfEntry 9 }
|
|
|
|
juniAtmSubIfMartiniTimeoutTimerId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..3)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timer identifier used to abandon cell aggregation when no
|
|
cells are supplied for transmission in ATM Martini cell-relay mode."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmSubIfEntry 10 }
|
|
|
|
juniAtmSubIfAssociatedVcClassId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier of the ATM VC class associated with this ATM
|
|
sub interface. A value for this identifier is determined by locating or
|
|
creating an ATM VC class name in the juniAtmVcClassNameTable. A value of 0
|
|
means no VC class association exists for this interface."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfEntry 11 }
|
|
|
|
|
|
--
|
|
-- The ATM Subinterface VCC Table
|
|
--
|
|
juniAtmSubIfVccTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmSubIfVccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM VCCs configured on ATM
|
|
subinterfaces present in the system.
|
|
|
|
An implementation may constrain the number of VCCs permitted to be
|
|
configured per ATM Subinterface; in particular, an implementation may
|
|
restrict each ATM Subinterface to have a single VCC.
|
|
|
|
Attributes in this entry can only be configured at entry creation, and
|
|
remain fixed for the lifetime of the entry."
|
|
::= { juniAtmSubIfLayer 3 }
|
|
|
|
juniAtmSubIfVccEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmSubIfVccEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM subinterface VCC."
|
|
INDEX { juniAtmSubIfIndex,
|
|
juniAtmSubIfVccVpi,
|
|
juniAtmSubIfVccVci }
|
|
::= { juniAtmSubIfVccTable 1 }
|
|
|
|
JuniAtmSubIfVccEntry ::= SEQUENCE {
|
|
juniAtmSubIfVccVpi AtmVpIdentifier,
|
|
juniAtmSubIfVccVci AtmVcIdentifier,
|
|
juniAtmSubIfVccRowStatus RowStatus,
|
|
juniAtmSubIfVccVcd Integer32,
|
|
juniAtmSubIfVccType INTEGER,
|
|
juniAtmSubIfVccServiceCategory INTEGER,
|
|
juniAtmSubIfVccPcr Integer32,
|
|
juniAtmSubIfVccScr Integer32,
|
|
juniAtmSubIfVccMbs Integer32,
|
|
juniAtmSubIfInverseArp TruthValue,
|
|
juniAtmSubIfInverseArpRefresh Integer32,
|
|
juniAtmSubIfVccAssociatedVcClassId Unsigned32 }
|
|
|
|
juniAtmSubIfVccVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the ATM VCC used by this subinterface."
|
|
::= { juniAtmSubIfVccEntry 1 }
|
|
|
|
juniAtmSubIfVccVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the ATM VCC used by this subinterface."
|
|
::= { juniAtmSubIfVccEntry 2 }
|
|
|
|
juniAtmSubIfVccRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
To create an entry in this table, the following entry objects MUST be
|
|
explicitly configured:
|
|
juniAtmSubIfVccRowStatus
|
|
|
|
In addition, when creating an entry the following conditions must hold:
|
|
The ATM Subinterface identified by juniAtmSubIfIndex must exist.
|
|
|
|
A positive value configured for juniAtmSubIfVccVcd must not already
|
|
be assigned to an existing VCC.
|
|
|
|
For each value of juniAtmSubIfVccServiceCategory, additional
|
|
dependent objects in the entry require configuration as identified
|
|
here:
|
|
|
|
juniAtmSubIfVccServiceCategory Requires configuration of:
|
|
------------------------------------------------------------
|
|
ubr <none>
|
|
|
|
ubrPcr juniAtmSubIfVccPcr
|
|
|
|
nrtVbr juniAtmSubIfVccPcr
|
|
juniAtmSubIfVccScr
|
|
juniAtmSubIfVccMbs
|
|
|
|
cbr juniAtmSubIfVccPcr
|
|
|
|
rtVbr juniAtmSubIfVccPcr
|
|
juniAtmSubIfVccScr
|
|
juniAtmSubIfVccMbs
|
|
------------------------------------------------------------
|
|
|
|
Attributes in this entry can only be configured at entry creation,
|
|
and remain fixed for the lifetime of the entry."
|
|
::= { juniAtmSubIfVccEntry 3 }
|
|
|
|
juniAtmSubIfVccVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer identifier for the circuit, used in conjunction with the
|
|
command-line interface. It is provided here for cross-reference
|
|
purposes only.
|
|
|
|
The value must be unique among VCCs configured on the same underlying
|
|
ATM interface.
|
|
|
|
If this object is not configured, or is configured with a value of zero,
|
|
a value will be allocated internally and can be queried after table
|
|
entry creation has succeeded."
|
|
::= { juniAtmSubIfVccEntry 4 }
|
|
|
|
juniAtmSubIfVccType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rfc1483VcMux(0),
|
|
rfc1483Llc(1),
|
|
autoconfig(2),
|
|
aal5(3),
|
|
aal0(4) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the encapsulation used by the circuit to carry IP datagrams.
|
|
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
|
|
over ATM. The 'autoconfig' value will recognize both VcMux and LLC
|
|
formats. The 'aal5' and 'aal0' values are used for encapsulation
|
|
methods for transport of ATM frames and cells over IP and MPLS networks
|
|
when no encapsulation method is specified."
|
|
DEFVAL { rfc1483VcMux }
|
|
::= { juniAtmSubIfVccEntry 5 }
|
|
|
|
juniAtmSubIfVccServiceCategory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ubr(0),
|
|
ubrPcr(1),
|
|
nrtVbr(2),
|
|
cbr(3),
|
|
rtVbr(4) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service category for this circuit:
|
|
ubr Unspecified Bit Rate (best effort).
|
|
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
|
|
nrtVbr Non-RealTime Variable Bit Rate.
|
|
cbr Constant Bit Rate.
|
|
rtVbr Realtime Variable Bit Rate."
|
|
DEFVAL { ubr }
|
|
::= { juniAtmSubIfVccEntry 6 }
|
|
|
|
juniAtmSubIfVccPcr OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peak Cell Rate, in kilobits per second (kbps), of this circuit.
|
|
|
|
This parameter is only required when juniAtmSubIfVccServiceCategory is
|
|
configured to have one of the following values:
|
|
ubrPcr
|
|
nrtVbr
|
|
cbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfVccEntry 7 }
|
|
|
|
juniAtmSubIfVccScr OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sustained Cell Rate, in kilobits per second (kbps), of this circuit.
|
|
|
|
This parameter is only required when juniAtmSubIfVccServiceCategory is
|
|
configured to have the following value:
|
|
nrtVbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfVccEntry 8 }
|
|
|
|
juniAtmSubIfVccMbs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16777215)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Burst Size, in cells, of this circuit.
|
|
|
|
This parameter is only required when juniAtmSubIfVccServiceCategory is
|
|
configured to have the following value:
|
|
nrtVbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfVccEntry 9 }
|
|
|
|
juniAtmSubIfInverseArp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables the inverse ARP protocol on this VCC; true(1) enables the
|
|
protocol, false(2) disables it."
|
|
::= { juniAtmSubIfVccEntry 10 }
|
|
|
|
juniAtmSubIfInverseArpRefresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..60)
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The refresh rate in minutes between inverse ARP protocol messages."
|
|
::= { juniAtmSubIfVccEntry 11 }
|
|
|
|
juniAtmSubIfVccAssociatedVcClassId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier of the ATM VC class associated with this ATM
|
|
sub interface. A value for this identifier is determined by locating or
|
|
creating an ATM VC class name in the juniAtmVcClassNameTable. A value
|
|
of 0 means no VC class association exists for this VC."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfVccEntry 12 }
|
|
|
|
|
|
--
|
|
-- The ATM OAM Table
|
|
--
|
|
juniAtmCircuitOamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmCircuitOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains circuit OAM data for a PVC."
|
|
::= { juniAtmSubIfLayer 4 }
|
|
|
|
juniAtmCircuitOamEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmCircuitOamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry provides OAM data on an ATM PVC."
|
|
INDEX { juniAtmCircuitOamIfIndex,
|
|
juniAtmCircuitOamVpi,
|
|
juniAtmCircuitOamVci }
|
|
::= { juniAtmCircuitOamTable 1 }
|
|
|
|
JuniAtmCircuitOamEntry ::= SEQUENCE {
|
|
juniAtmCircuitOamIfIndex InterfaceIndex,
|
|
juniAtmCircuitOamVpi AtmVpIdentifier,
|
|
juniAtmCircuitOamVci AtmVcIdentifier,
|
|
juniAtmCircuitOamAdminStatus INTEGER,
|
|
juniAtmCircuitOamLoopbackOperStatus INTEGER,
|
|
juniAtmCircuitVcOamOperStatus INTEGER,
|
|
juniAtmCircuitOamLoopbackFrequency Integer32,
|
|
juniAtmCircuitInOamF5Cells Counter32,
|
|
juniAtmCircuitInOamCellsDropped Counter32,
|
|
juniAtmCircuitOutOamF5Cells Counter32,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells Counter32,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells Counter32,
|
|
juniAtmCircuitInOamF5AisCells Counter32,
|
|
juniAtmCircuitInOamF5RdiCells Counter32,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells Counter32,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells Counter32,
|
|
juniAtmCircuitOutOamF5RdiCells Counter32,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds Counter32,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps Counter32,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds Counter32,
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps Counter32,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds Counter32,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps Counter32,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds Counter32,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps Counter32,
|
|
juniAtmCircuitOamUpCount Integer32,
|
|
juniAtmCircuitOamDownCount Integer32,
|
|
juniAtmCircuitOamRetryFrequency Integer32,
|
|
juniAtmCircuitOamAlarmDownCount Integer32,
|
|
juniAtmCircuitOamAlarmClearTimeout Integer32 }
|
|
|
|
juniAtmCircuitOamIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM subinterface."
|
|
::= { juniAtmCircuitOamEntry 1 }
|
|
|
|
juniAtmCircuitOamVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI of the ATM VCC used by this ATM interface and PVC."
|
|
::= { juniAtmCircuitOamEntry 2 }
|
|
|
|
juniAtmCircuitOamVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI of the ATM VCC used by this ATM interface and PVC."
|
|
::= { juniAtmCircuitOamEntry 3 }
|
|
|
|
juniAtmCircuitOamAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamAdminStateDisabled(1),
|
|
oamAdminStateEnabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative state of OAM for the interface identified by this
|
|
entry."
|
|
DEFVAL { oamAdminStateDisabled }
|
|
::= { juniAtmCircuitOamEntry 4 }
|
|
|
|
juniAtmCircuitOamLoopbackOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamOperStatusNotSupported(0),
|
|
oamOperStatusDisabled(1),
|
|
oamOperStatusSent(2),
|
|
oamOperStatusReceived(3),
|
|
oamOperStatusFailed(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational status of OAM for the interface identified by this
|
|
entry.
|
|
oamOperStatusNotSupported(0) - OAM not supported on this interface
|
|
oamOperStatusDisabled(1) - VC integrity disabled
|
|
oamOperStatusSent(2) - Loopback sent, awaiting response
|
|
oamOperStatusReceived(3) - Loopback response received, awaiting
|
|
frequency
|
|
oamOperStatusFailed(4) - Loopback response not received, or
|
|
invalid response received"
|
|
::= { juniAtmCircuitOamEntry 5 }
|
|
|
|
juniAtmCircuitVcOamOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamVcOperStateAisState(0),
|
|
oamVcOperStateRdiState(1),
|
|
oamVcOperStateDownRetry(2),
|
|
oamVcOperStateUpRetry(3),
|
|
oamVcOperStateUp(4),
|
|
oamVcOperStateDown(5),
|
|
oamVcOperStateNotManaged(6),
|
|
oamVcOperStateVpAis(7),
|
|
oamVcOperStateVpRdi(8),
|
|
oamVcOperStateVcInVpRdi(9),
|
|
oamVcoperStateVcInVpAis(10),
|
|
oamVcOperStateSegAis(11),
|
|
oamVcOperStateSegRdi(12),
|
|
oamVcOperStateGenAis(13)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM VC operational status of this entry.
|
|
oamVcOperStateAisState(0) - AIS cell received or underlying
|
|
physical layer reporting transmission
|
|
path AIS
|
|
oamVcOperStateRdiState(1) - RDI cell received
|
|
oamVcOperStateDownRetry(2) - OAM loopback failed, using retry
|
|
frequency to verify that the VC is
|
|
really down
|
|
oamVcOperStateUpRetry(3) - OAM loopback successful, using retry
|
|
frequency to verify that the VC is
|
|
really up
|
|
oamVcOperStateUp(4) - OAM loopback successful after up retry
|
|
verification
|
|
oamVcOperStateDown(5) - OAM loopback failed after down retry
|
|
verification
|
|
oamVcOperStateNotManaged(6)- No verification via loopback cells
|
|
being performed
|
|
oamVcOperStateVpAis(7) - F4 AIS cell received
|
|
oamVcOperStateVpRdi(8) - F4 RDI cell received
|
|
oamVcOperStateVcInVpRdi(9) - F4 RDI cell received; path failure
|
|
oamVcOperStateVcInVpAis(10)- F4 AIS cell received; path failure
|
|
oamVcOperStateSegAis(11) - Segment AIS cell received
|
|
oamVcOperStateSegRdi(12) - Segment RDI cell received
|
|
oamVcOperStateGenAis(13) - Connection failure; generating AIS
|
|
cells."
|
|
::= { juniAtmCircuitOamEntry 6 }
|
|
|
|
juniAtmCircuitOamLoopbackFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM loopback frequency in seconds."
|
|
DEFVAL { 10 }
|
|
::= { juniAtmCircuitOamEntry 7 }
|
|
|
|
juniAtmCircuitInOamF5Cells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 cells."
|
|
::= { juniAtmCircuitOamEntry 8 }
|
|
|
|
juniAtmCircuitInOamCellsDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM cells that were dropped."
|
|
::= { juniAtmCircuitOamEntry 9 }
|
|
|
|
juniAtmCircuitOutOamF5Cells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 cells."
|
|
::= { juniAtmCircuitOamEntry 10 }
|
|
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total received OAM F5 end-to-end loopback cells. Aggregate of
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds and
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps"
|
|
::= { juniAtmCircuitOamEntry 11 }
|
|
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total received OAM F5 segment loopback cells. Aggregate of
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds and
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps"
|
|
::= { juniAtmCircuitOamEntry 12 }
|
|
|
|
juniAtmCircuitInOamF5AisCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 AIS cells."
|
|
::= { juniAtmCircuitOamEntry 13 }
|
|
|
|
juniAtmCircuitInOamF5RdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 RDI cells."
|
|
::= { juniAtmCircuitOamEntry 14 }
|
|
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total transmitted OAM F5 end-to-end loopback cells. Aggregate of
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds and
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps"
|
|
::= { juniAtmCircuitOamEntry 15 }
|
|
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total transmitted OAM F5 segment loopback cells. Aggregate of
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds and
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps"
|
|
::= { juniAtmCircuitOamEntry 16 }
|
|
|
|
juniAtmCircuitOutOamF5RdiCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 RDI cells."
|
|
::= { juniAtmCircuitOamEntry 17 }
|
|
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 end-to-end loopback commands."
|
|
::= { juniAtmCircuitOamEntry 18 }
|
|
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 end-to-end loopback responses."
|
|
::= { juniAtmCircuitOamEntry 19 }
|
|
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 segment loopback commands."
|
|
::= { juniAtmCircuitOamEntry 20 }
|
|
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Received OAM F5 segment loopback responses."
|
|
::= { juniAtmCircuitOamEntry 21 }
|
|
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 end-to-end loopback commands."
|
|
::= { juniAtmCircuitOamEntry 22 }
|
|
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 end-to-end loopback responses."
|
|
::= { juniAtmCircuitOamEntry 23 }
|
|
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 segment loopback commands."
|
|
::= { juniAtmCircuitOamEntry 24 }
|
|
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmitted OAM F5 segment loopback responses."
|
|
::= { juniAtmCircuitOamEntry 25 }
|
|
|
|
juniAtmCircuitOamUpCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive loopback cell responses to receive
|
|
before a PVC is up for connectivity verification."
|
|
DEFVAL { 3 }
|
|
::= { juniAtmCircuitOamEntry 26 }
|
|
|
|
juniAtmCircuitOamDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive loopback cell responses not received
|
|
before declaring a PVC down for connectivity verification."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmCircuitOamEntry 27 }
|
|
|
|
juniAtmCircuitOamRetryFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the frequency (in seconds) to transmit loopback cells when
|
|
verifying PVC state (up or down) for connectivity verification."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmCircuitOamEntry 28 }
|
|
|
|
juniAtmCircuitOamAlarmDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive alarm (AIS or RDI) cells to receive
|
|
before declaring a PVC down."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmCircuitOamEntry 29 }
|
|
|
|
juniAtmCircuitOamAlarmClearTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (3..60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies how long to wait (in seconds) before declaring a PVC up after
|
|
it has stopped receiving alarm cells."
|
|
DEFVAL { 3 }
|
|
::= { juniAtmCircuitOamEntry 30 }
|
|
|
|
--
|
|
-- The ATM Subinterface VCC Traffic Shaping Table
|
|
--
|
|
juniAtmSubIfVccTrafficShapingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmSubIfVccTrafficShapingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for traffic shaping of ATM VCCs configured
|
|
on ATM subinterfaces present in the system. This table augments the
|
|
juniAtmSubIfVccTable only for VCCs that support traffic shapping.
|
|
|
|
Attributes in this entry can only be configured at entry creation, and
|
|
remain fixed for the lifetime of the entry."
|
|
::= { juniAtmSubIfLayer 5 }
|
|
|
|
juniAtmSubIfVccTrafficShapingEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmSubIfVccTrafficShapingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the traffic shping characteristics of an ATM
|
|
subinterface VCC."
|
|
AUGMENTS { juniAtmSubIfVccEntry }
|
|
::= { juniAtmSubIfVccTrafficShapingTable 1 }
|
|
|
|
JuniAtmSubIfVccTrafficShapingEntry ::= SEQUENCE {
|
|
juniAtmSubIfVccTrafficShapingCdvt Unsigned32,
|
|
juniAtmSubIfVccTrafficShapingClp0 TruthValue,
|
|
juniAtmSubIfVccTrafficShapingTagging TruthValue,
|
|
juniAtmSubIfVccTrafficShapingPoliceObserve TruthValue,
|
|
juniAtmSubIfVccTrafficShapingPacketShaping TruthValue }
|
|
|
|
juniAtmSubIfVccTrafficShapingCdvt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "tenths of a microsecond"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The network cell delay variation tolerance (CDVT) in tenths of a
|
|
microsecond."
|
|
::= { juniAtmSubIfVccTrafficShapingEntry 1 }
|
|
|
|
juniAtmSubIfVccTrafficShapingClp0 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether or not only CLP0 cells are to be policed according to
|
|
the traffic contract. CLP1 cells are forwarded on a best-effort basis
|
|
CLP-significant model for (VBR.2, VBR.3 conformance). Applicable only
|
|
for VBR circuits."
|
|
::= { juniAtmSubIfVccTrafficShapingEntry 2 }
|
|
|
|
juniAtmSubIfVccTrafficShapingTagging OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether or not CLP0 cells should be tagged for SCR policing
|
|
(VBR.3 conformance). Applicable only for VBR circuits."
|
|
::= { juniAtmSubIfVccTrafficShapingEntry 3 }
|
|
|
|
juniAtmSubIfVccTrafficShapingPoliceObserve OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether of not no policing action is to be taken (note the
|
|
double negative; if true(1) then no policing action will be taken; if
|
|
false(2) then policing action will be taken). Regardless of the state
|
|
of this object, all counters will be incremented."
|
|
::= { juniAtmSubIfVccTrafficShapingEntry 4 }
|
|
|
|
juniAtmSubIfVccTrafficShapingPacketShaping OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether of not to shape output traffic on a packet boundary."
|
|
::= { juniAtmSubIfVccTrafficShapingEntry 5 }
|
|
|
|
|
|
--
|
|
-- The juniAtmSubIfSvcConfigTable for ATM switched
|
|
-- virtual connections (SVCs).
|
|
--
|
|
juniAtmSubIfSvcConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmSubIfSvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This table contains entries for extending the juniAtmSubIfTable to
|
|
configure switched virtual connection (SVC) on the subinterfaces."
|
|
::= { juniAtmSubIfLayer 6 }
|
|
|
|
juniAtmSubIfSvcConfigEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmSubIfSvcConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Each entry provides configuration parameters for an ATM SVC on the
|
|
subinterface."
|
|
INDEX { juniAtmSubIfIndex }
|
|
::= { juniAtmSubIfSvcConfigTable 1 }
|
|
|
|
JuniAtmSubIfSvcConfigEntry ::= SEQUENCE {
|
|
juniAtmSubIfSvcRowStatus RowStatus,
|
|
juniAtmSubIfSvcConfigDestAtmAddress AtmAddr,
|
|
juniAtmSubIfSvcConfigCircuitType INTEGER,
|
|
juniAtmSubIfSvcConfigServiceCategory INTEGER,
|
|
juniAtmSubIfSvcConfigPcr Unsigned32,
|
|
juniAtmSubIfSvcConfigScr Unsigned32,
|
|
juniAtmSubIfSvcConfigMbs Unsigned32,
|
|
juniAtmSubIfSvcConfigCdvt Unsigned32,
|
|
juniAtmSubIfSvcConfigClp0 TruthValue,
|
|
juniAtmSubIfSvcConfigTagging TruthValue,
|
|
juniAtmSubIfSvcConfigObserve TruthValue,
|
|
juniAtmSubIfSvcConfigPacketDiscard TruthValue,
|
|
juniAtmSubIfSvcConfigDestE164Address AtmAddr }
|
|
|
|
juniAtmSubIfSvcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy "
|
|
::= { juniAtmSubIfSvcConfigEntry 1 }
|
|
|
|
juniAtmSubIfSvcConfigDestAtmAddress OBJECT-TYPE
|
|
SYNTAX AtmAddr (SIZE(20))
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the destination ATM NSAP address of the circuit."
|
|
::= { juniAtmSubIfSvcConfigEntry 2 }
|
|
|
|
juniAtmSubIfSvcConfigCircuitType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rfc1483VcMux(0),
|
|
rfc1483Llc(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specifies the encapsulation used by the circuit to carry IP datagrams.
|
|
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
|
|
over ATM."
|
|
DEFVAL { rfc1483VcMux }
|
|
::= { juniAtmSubIfSvcConfigEntry 3 }
|
|
|
|
juniAtmSubIfSvcConfigServiceCategory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ubr(0),
|
|
ubrPcr(1),
|
|
nrtVbr(2),
|
|
cbr(3),
|
|
rtVbr(4) }
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Service category for this circuit:
|
|
ubr Unspecified Bit Rate (best effort).
|
|
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
|
|
nrtVbr Non-RealTime Variable Bit Rate.
|
|
cbr Constant Bit Rate.
|
|
rtVbr Realtime Variable Bit Rate."
|
|
DEFVAL { ubr }
|
|
::= { juniAtmSubIfSvcConfigEntry 4 }
|
|
|
|
juniAtmSubIfSvcConfigPcr OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Peak Cell Rate, in kilo-bits per second (kbps), of this circuit."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfSvcConfigEntry 5 }
|
|
|
|
juniAtmSubIfSvcConfigScr OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Sustained Cell Rate, in kilo-bits per second (kbps), of this circuit."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfSvcConfigEntry 6 }
|
|
|
|
juniAtmSubIfSvcConfigMbs OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "cells"
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Maximum Burst Size, in cells, of this circuit."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmSubIfSvcConfigEntry 7 }
|
|
|
|
juniAtmSubIfSvcConfigCdvt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "100us"
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Specify the network Cell Delay Variation Tolerance."
|
|
::= { juniAtmSubIfSvcConfigEntry 8 }
|
|
|
|
juniAtmSubIfSvcConfigClp0 OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specify that only CLP0 cells are to be policed according to the traffic
|
|
contract. CLP1 cells are forwarded on a best-effort basis
|
|
CLP-significant model for (VBR.2, VBR.3 conformance)."
|
|
::= { juniAtmSubIfSvcConfigEntry 9 }
|
|
|
|
juniAtmSubIfSvcConfigTagging OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Specify that CLP0 cells should be tagged for SCR policing (VBR.3
|
|
conformance)."
|
|
::= { juniAtmSubIfSvcConfigEntry 10 }
|
|
|
|
juniAtmSubIfSvcConfigObserve OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Specify that no policing action is to be taken; only counters are
|
|
incremented."
|
|
::= { juniAtmSubIfSvcConfigEntry 11 }
|
|
|
|
juniAtmSubIfSvcConfigPacketDiscard OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable early packet Discard for this circuit."
|
|
::= { juniAtmSubIfSvcConfigEntry 12 }
|
|
|
|
juniAtmSubIfSvcConfigDestE164Address OBJECT-TYPE
|
|
SYNTAX AtmAddr (SIZE(0|8))
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Specifies the destination ATM E164 address of the circuit."
|
|
::= { juniAtmSubIfSvcConfigEntry 13 }
|
|
|
|
--
|
|
-- The ATM subinterface description export object
|
|
--
|
|
juniAtmSubIfDescriptionExport OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling of this object will program the subinterface description down
|
|
to the applicable line card. Note, the subinterface description sent
|
|
down to the line card is a truncated version (32 bytes) of the ifAlias."
|
|
DEFVAL { false }
|
|
::= { juniAtmSubIfLayer 7 }
|
|
|
|
|
|
--
|
|
-- The ATM NBMA table
|
|
--
|
|
juniAtmNbmaMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmNbmaMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM NBMA maps."
|
|
::= { juniAtmNbma 1 }
|
|
|
|
juniAtmNbmaMapEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmNbmaMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM NBMA map."
|
|
INDEX { juniAtmNbmaMapName,
|
|
juniAtmNbmaMapVcd }
|
|
::= { juniAtmNbmaMapTable 1 }
|
|
|
|
JuniAtmNbmaMapEntry ::= SEQUENCE {
|
|
juniAtmNbmaMapName JuniAtmNbmaMapName,
|
|
juniAtmNbmaMapVcd Integer32,
|
|
juniAtmNbmaMapIpAddress IpAddress,
|
|
juniAtmNbmaMapVpi AtmVpIdentifier,
|
|
juniAtmNbmaMapVci AtmVcIdentifier,
|
|
juniAtmNbmaMapIfIndex InterfaceIndexOrZero,
|
|
juniAtmNbmaMapBroadcast TruthValue,
|
|
juniAtmNbmaMapRowStatus RowStatus }
|
|
|
|
juniAtmNbmaMapName OBJECT-TYPE
|
|
SYNTAX JuniAtmNbmaMapName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NBMA map name."
|
|
::= { juniAtmNbmaMapEntry 1 }
|
|
|
|
juniAtmNbmaMapVcd OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer identifier for the ATM circuit, used in conjunction with the
|
|
command-line interface.
|
|
|
|
The value must be unique among VCs configured on the same ATM
|
|
interface."
|
|
::= { juniAtmNbmaMapEntry 2 }
|
|
|
|
juniAtmNbmaMapIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address associated with this entry."
|
|
::= { juniAtmNbmaMapEntry 3 }
|
|
|
|
juniAtmNbmaMapVpi OBJECT-TYPE
|
|
SYNTAX AtmVpIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VPI identifier of the ATM circuit."
|
|
::= { juniAtmNbmaMapEntry 4 }
|
|
|
|
juniAtmNbmaMapVci OBJECT-TYPE
|
|
SYNTAX AtmVcIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VCI identifier of the ATM circuit."
|
|
::= { juniAtmNbmaMapEntry 5 }
|
|
|
|
juniAtmNbmaMapIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex of the ATM major interface associated with this entry.
|
|
The value of this object will be zero when the map is not applied
|
|
to an interface. "
|
|
::= { juniAtmNbmaMapEntry 6 }
|
|
|
|
juniAtmNbmaMapBroadcast OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The broadcast enable/disable setting for this entry. The value true(1)
|
|
enable broadcast support; disable(2) disabled broadcast support for this
|
|
entry."
|
|
::= { juniAtmNbmaMapEntry 7 }
|
|
|
|
juniAtmNbmaMapRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy
|
|
|
|
Additional notes to aid the network manager:
|
|
- NBMA maps are not supported on dynamic interface.
|
|
- NBMA maps can only be applied to a single major ATM interface at a
|
|
time.
|
|
- NBMA maps cannot be deleted unless the map is removed from the ATM
|
|
interface (juniAtmNbmaMapIfIndex = 0).
|
|
- The values of juniAtmNbmaMapVpi, juniAtmNbmaMapVci and
|
|
juniAtmNbmaMapIfIndex are zero until the map is applied to a major
|
|
ATM interface.
|
|
- To create an entry in this table, the following objects must be
|
|
present in the set PDU:
|
|
juniAtmNbmaMapIpAddress
|
|
juniAtmNbmaMapBroadcast
|
|
juniAtmNbmaMapRowStatus
|
|
- Once created, only the following objects can be modified:
|
|
juniAtmNbmaMapBroadcast "
|
|
::= { juniAtmNbmaMapEntry 8 }
|
|
|
|
juniAtmNbmaMapListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmNbmaMapListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for ATM NBMA map lists."
|
|
::= { juniAtmNbma 2 }
|
|
|
|
juniAtmNbmaMapListEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmNbmaMapListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics of an ATM NBMA map."
|
|
INDEX { IMPLIED juniAtmNbmaMapListName }
|
|
::= { juniAtmNbmaMapListTable 1 }
|
|
|
|
JuniAtmNbmaMapListEntry ::= SEQUENCE {
|
|
juniAtmNbmaMapListName JuniAtmNbmaMapName,
|
|
juniAtmNbmaMapListRowStatus RowStatus }
|
|
|
|
juniAtmNbmaMapListName OBJECT-TYPE
|
|
SYNTAX JuniAtmNbmaMapName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NBMA Map List name."
|
|
::= { juniAtmNbmaMapListEntry 1 }
|
|
|
|
juniAtmNbmaMapListRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table according to the
|
|
RowStatus textual convention, constrained to support the following
|
|
values only:
|
|
createAndGo
|
|
destroy "
|
|
::= { juniAtmNbmaMapListEntry 2 }
|
|
|
|
|
|
--
|
|
-- The ATM ping tests.
|
|
--
|
|
|
|
--
|
|
-- ATM ping test types.
|
|
--
|
|
juniAtmPingTestTypes OBJECT IDENTIFIER
|
|
::= { juniAtmPing 1 }
|
|
|
|
juniAtmPingTestOamSeg OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
|
|
VCL, or VCC termination point, using segment OAM cells.
|
|
|
|
The test type must have appended to it a code that uniquely identifies
|
|
an intermediate point responsible for looping back each cell. If this
|
|
is absent, the loopbacks are performed at the end of the segment or
|
|
connection.
|
|
|
|
E.g., the OID { juniAtmPingTestOamSeg 5 } identifies that the loopbacks
|
|
should be performed at the intermediate point labeled 5."
|
|
::= { juniAtmPingTestTypes 1 }
|
|
|
|
juniAtmPingTestOamE2E OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This identifies an OAM Ping (multiple loopbacks) Test on a VPL, VPC,
|
|
VCL, or VCC termination point, using end-to-end OAM cells."
|
|
::= { juniAtmPingTestTypes 2 }
|
|
|
|
|
|
--
|
|
-- The juniAtmVpPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VpTestTable.
|
|
--
|
|
juniAtmVpPingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVpPingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
|
|
atmM4VpTestTable to do ping (multiple loopback) type testing."
|
|
::= { juniAtmPing 2 }
|
|
|
|
juniAtmVpPingEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVpPingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics, status and results of the
|
|
most recent ATM ping test."
|
|
INDEX { ifIndex,
|
|
atmVplVpi,
|
|
atmfM4VpTestObject }
|
|
::= { juniAtmVpPingTable 1 }
|
|
|
|
JuniAtmVpPingEntry ::= SEQUENCE {
|
|
juniAtmVpPingProbeCount Unsigned32,
|
|
juniAtmVpPingTimeOut Unsigned32,
|
|
juniAtmVpPingCtlTrapGeneration BITS,
|
|
juniAtmVpPingSentProbes Unsigned32,
|
|
juniAtmVpPingProbeResponses Unsigned32,
|
|
juniAtmVpPingStartTime TimeStamp,
|
|
juniAtmVpPingMinRtt Unsigned32,
|
|
juniAtmVpPingMaxRtt Unsigned32,
|
|
juniAtmVpPingAverageRtt Unsigned32 }
|
|
|
|
juniAtmVpPingProbeCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..32)
|
|
UNITS "probes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping probes (OAM cells) to be sent to complete the test."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmVpPingEntry 1 }
|
|
|
|
juniAtmVpPingTimeOut OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..5)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time-out value, in seconds, for a remote ping operation."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmVpPingEntry 2 }
|
|
|
|
juniAtmVpPingCtlTrapGeneration OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
testCompletion(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object determines when and if to generate a
|
|
notification for this entry:
|
|
|
|
testCompletion(0) - Generate a juniPingTestCompleted notification.
|
|
|
|
The value of this object defaults to zero, indicating that no
|
|
notification has been selected."
|
|
DEFVAL { { } }
|
|
::= { juniAtmVpPingEntry 3 }
|
|
|
|
juniAtmVpPingSentProbes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "probes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping probes (OAM cells) that have been sent thus far for
|
|
this test. The value of this object MUST be set to zero when the
|
|
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVpPingEntry 4 }
|
|
|
|
juniAtmVpPingProbeResponses OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "probes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping responses that have been received thus far for this
|
|
test. The value of this object MUST be set to zero when the
|
|
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVpPingEntry 5 }
|
|
|
|
juniAtmVpPingStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (sysUpTime) when the test started."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVpPingEntry 6 }
|
|
|
|
juniAtmVpPingMinRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shortest round-trip-time (RTT) for the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVpPingEntry 7 }
|
|
|
|
juniAtmVpPingMaxRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The longest round-trip-time (RTT) for the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVpPingEntry 8 }
|
|
|
|
juniAtmVpPingAverageRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average round-trip-time (RTT) for all the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VpTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVpPingEntry 9 }
|
|
|
|
|
|
--
|
|
-- The juniAtmVcPingTable extends the ATM-FORUM-SNMP-M4-MIB.atmM4VcTestTable.
|
|
--
|
|
juniAtmVcPingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVcPingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains entries for extending the ATM-FORUM-SNMP-M4-MIB
|
|
atmM4VcTestTable to do ping (multiple loopback) type testing."
|
|
::= { juniAtmPing 3 }
|
|
|
|
juniAtmVcPingEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVcPingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry describes the characteristics, status and results of the
|
|
most recent ATM ping test."
|
|
INDEX { ifIndex,
|
|
atmVclVpi,
|
|
atmVclVci,
|
|
atmfM4VcTestObject }
|
|
::= { juniAtmVcPingTable 1 }
|
|
|
|
JuniAtmVcPingEntry ::= SEQUENCE {
|
|
juniAtmVcPingProbeCount Unsigned32,
|
|
juniAtmVcPingTimeOut Unsigned32,
|
|
juniAtmVcPingCtlTrapGeneration BITS,
|
|
juniAtmVcPingSentProbes Unsigned32,
|
|
juniAtmVcPingProbeResponses Unsigned32,
|
|
juniAtmVcPingStartTime TimeStamp,
|
|
juniAtmVcPingMinRtt Unsigned32,
|
|
juniAtmVcPingMaxRtt Unsigned32,
|
|
juniAtmVcPingAverageRtt Unsigned32 }
|
|
|
|
juniAtmVcPingProbeCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..32)
|
|
UNITS "probes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping probes (OAM cells) to be sent to complete the test."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmVcPingEntry 1 }
|
|
|
|
juniAtmVcPingTimeOut OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..5)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time-out value, in seconds, for a remote ping operation."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmVcPingEntry 2 }
|
|
|
|
juniAtmVcPingCtlTrapGeneration OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
testCompletion(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object determines when and if to generate a
|
|
notification for this entry:
|
|
testCompletion(0) - Generate a juniPingTestCompleted notification.
|
|
|
|
The value of this object defaults to zero, indicating that no
|
|
notification has been selected."
|
|
DEFVAL { { } }
|
|
::= { juniAtmVcPingEntry 3 }
|
|
|
|
juniAtmVcPingSentProbes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "probes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping probes (OAM cells) that have been sent thus far for
|
|
this test. The value of this object MUST be set to zero when the
|
|
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcPingEntry 4 }
|
|
|
|
juniAtmVcPingProbeResponses OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "probes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of ping responses that have been received thus far for this
|
|
test. The value of this object MUST be set to zero when the
|
|
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1)."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcPingEntry 5 }
|
|
|
|
juniAtmVcPingStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (sysUpTime) when the test started."
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcPingEntry 6 }
|
|
|
|
juniAtmVcPingMinRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shortest round-trip-time (RTT) for the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVcPingEntry 7 }
|
|
|
|
juniAtmVcPingMaxRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The longest round-trip-time (RTT) for the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVcPingEntry 8 }
|
|
|
|
juniAtmVcPingAverageRtt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average round-trip-time (RTT) for all the pings that have received
|
|
responses. The value of this object MUST be set to zero when the
|
|
atmfM4VcTestStatus object transitions from notInUse(0) to inUse(1). A
|
|
value of zero for this object implies that no ping responses have been
|
|
received for the current test."
|
|
::= { juniAtmVcPingEntry 9 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- ATM ping test codes.
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniAtmPingTestCode OBJECT IDENTIFIER ::= { juniAtmPing 4 }
|
|
|
|
juniAtmPingTestCodeOamDisabled OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test code indicates that the ATM ping operation cannot be
|
|
initiated or is aborted because the juniAtmIfOamCellRxAdminState is set
|
|
to disabled."
|
|
::= { juniAtmPingTestCode 1 }
|
|
|
|
juniAtmPingTestCodeCircuitDown OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test code indicates that the ATM ping operation cannot be
|
|
initiated or is aborted because the operational status of the ATM
|
|
circuit is down."
|
|
::= { juniAtmPingTestCode 2 }
|
|
|
|
juniAtmPingTestCodeStopped OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test code indicates that the ATM ping operation is
|
|
administratively stopped by an External Management."
|
|
::= { juniAtmPingTestCode 3 }
|
|
|
|
juniAtmPingTestCodeOamVcOperState OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test code indicates that the ATM ping operation cannot be
|
|
initiated or is aborted because the circuit is down because of a OAM
|
|
fault condition. This is possible if juniAtmCircuitVcOamOperStatus is
|
|
one of the following:
|
|
oamVcOperStateAisState(0) - AIS cell received or underlying
|
|
physical layer reporting transmission
|
|
path AIS.
|
|
oamVcOperStateRdiState(1) - RDI cell received."
|
|
::= { juniAtmPingTestCode 4 }
|
|
|
|
juniAtmPingTestCodeMaxPingCountReached OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This test code indicates that the ping operation cannot be initiated as
|
|
the maximum number of ping possible on this interfaces exceeds the
|
|
allowable limit."
|
|
::= { juniAtmPingTestCode 5 }
|
|
|
|
juniAtmPingTestCodeInvalidParams OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Test Code identities the Ping operation cannot be initiated as one
|
|
or more of the Ping Parameters is Invalid."
|
|
::= { juniAtmPingTestCode 6 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- ATM Subinterface information by interface location
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniAtmSubIfLocationType OBJECT-TYPE
|
|
SYNTAX JuniInterfaceLocationType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the interpretation of JuniInterfaceLocationValue object
|
|
values into platform-dependent interface location components, e.g.,
|
|
'slot.port' on an ERX."
|
|
::= { juniAtmLocation 1 }
|
|
|
|
juniAtmSubIfLocationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmSubIfLocationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries in this table report the ifIndex of ATM Subinterfaces by
|
|
location."
|
|
::= { juniAtmLocation 2 }
|
|
|
|
juniAtmSubIfLocationEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmSubIfLocationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A specification of ATM subinterfaces by location."
|
|
INDEX { juniAtmSubIfLocationIndex,
|
|
juniAtmSubIfDistinguisher }
|
|
::= { juniAtmSubIfLocationTable 1 }
|
|
|
|
JuniAtmSubIfLocationEntry ::= SEQUENCE {
|
|
juniAtmSubIfLocationIndex JuniInterfaceLocationValue,
|
|
juniAtmSubIfLocationIfIndex InterfaceIndex }
|
|
|
|
juniAtmSubIfLocationIndex OBJECT-TYPE
|
|
SYNTAX JuniInterfaceLocationValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of a platform interface location."
|
|
::= { juniAtmSubIfLocationEntry 1 }
|
|
|
|
juniAtmSubIfLocationIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ifIndex value of this subinterface."
|
|
::= { juniAtmSubIfLocationEntry 2 }
|
|
|
|
|
|
juniAtmVcClassNameTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVcClassNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entries in this table provide mappings of ATM VC class names to
|
|
local integer identifiers. These integers are used as indexes into other
|
|
MIB tables containing ATM VC attributes associated with the same VC class name."
|
|
::= { juniAtmVcClass 1 }
|
|
|
|
juniAtmVcClassNameEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVcClassNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mapping of ATM VC class name to an integer identifier for the ATM VC class."
|
|
INDEX { IMPLIED juniAtmVcClassName }
|
|
::= { juniAtmVcClassNameTable 1 }
|
|
|
|
JuniAtmVcClassNameEntry ::= SEQUENCE {
|
|
juniAtmVcClassName DisplayString,
|
|
juniAtmVcClassNameRowStatus RowStatus,
|
|
juniAtmVcClassNameId Unsigned32 }
|
|
|
|
juniAtmVcClassName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC class name uniquely identifying this entry."
|
|
::= { juniAtmVcClassNameEntry 1 }
|
|
|
|
juniAtmVcClassNameRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls creation/deletion of entries in this table. Only the values
|
|
'createAndGo' ,'destroy', 'active' and 'notInService' may be SET.
|
|
The SNMP manager would set the row status to notInService before making
|
|
any VC class attribute changes explained in juniAtmVcClassTable. Once the
|
|
VC class attribute changes are complete, the SNMP manager would set the
|
|
row status to active, upon which the VC class attribute changes would
|
|
be committed. Any ATM VC class attribute changes that are made when the
|
|
row status is 'active' are committed right away."
|
|
::= { juniAtmVcClassNameEntry 2 }
|
|
|
|
juniAtmVcClassNameId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this VC class name. The value of
|
|
this identifier is assigned by the device when an entry in this table
|
|
is created."
|
|
::= { juniAtmVcClassNameEntry 3 }
|
|
|
|
juniAtmVcClassIdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVcClassIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides inverse mapping of ATM VC class IDs to ATM VC class names."
|
|
::= { juniAtmVcClass 2 }
|
|
|
|
juniAtmVcClassIdEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVcClassIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mapping of an integer identifier to an ATM VC class name."
|
|
INDEX { juniAtmVcClassIdId }
|
|
::= { juniAtmVcClassIdTable 1 }
|
|
|
|
JuniAtmVcClassIdEntry ::= SEQUENCE {
|
|
juniAtmVcClassIdId Unsigned32,
|
|
juniAtmVcClassIdName DisplayString }
|
|
|
|
juniAtmVcClassIdId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this ATM VC class name."
|
|
::= { juniAtmVcClassIdEntry 1 }
|
|
|
|
juniAtmVcClassIdName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ATM VC class name having the associated identifier."
|
|
::= { juniAtmVcClassIdEntry 2 }
|
|
|
|
--
|
|
--ATM VC class table
|
|
--
|
|
juniAtmVcClassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF JuniAtmVcClassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains Juniper ATM VC Class entries which can be used
|
|
to specify the ATM PVC attributes either at creation or modification
|
|
time. A row in this table with default values is created when an entry
|
|
in juniAtmVcClassNameTable is created."
|
|
::= { juniAtmVcClass 3 }
|
|
juniAtmVcClassEntry OBJECT-TYPE
|
|
SYNTAX JuniAtmVcClassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains the attributes of the ATM VC which would be
|
|
applied to the VC either at creation or modification time when this
|
|
ATM VC class is associated to it."
|
|
INDEX { juniAtmVcClassId }
|
|
|
|
::= { juniAtmVcClassTable 1 }
|
|
|
|
|
|
JuniAtmVcClassEntry ::= SEQUENCE {
|
|
juniAtmVcClassId Unsigned32,
|
|
juniAtmVcClassVccType INTEGER,
|
|
juniAtmVcClassVccServiceCategory INTEGER,
|
|
juniAtmVcClassVccPcr Integer32,
|
|
juniAtmVcClassVccScr Integer32,
|
|
juniAtmVcClassVccMbs Integer32,
|
|
juniAtmVcClassVccOamAdminStatus INTEGER,
|
|
juniAtmVcClassVccOamLoopbackFrequency Integer32,
|
|
juniAtmVcClassVccOamUpCount Integer32,
|
|
juniAtmVcClassVccOamDownCount Integer32,
|
|
juniAtmVcClassVccOamRetryFrequency Integer32,
|
|
juniAtmVcClassVccOamAlarmDownCount Integer32,
|
|
juniAtmVcClassVccOamAlarmClearTimeout Integer32,
|
|
juniAtmVcClassVccInverseArp TruthValue,
|
|
juniAtmVcClassVccInverseArpRefresh Integer32 }
|
|
|
|
juniAtmVcClassId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer identifier associated with this ATM VC class. A value
|
|
for this identifier is determined by locating or creating an ATM VC
|
|
class name in the juniAtmVcClassNameTable."
|
|
::= { juniAtmVcClassEntry 1 }
|
|
|
|
juniAtmVcClassVccType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rfc1483VcMux(0),
|
|
rfc1483Llc(1),
|
|
autoconfig(2),
|
|
aal5(3),
|
|
aal0(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the encapsulation used by the circuit to carry IP datagrams.
|
|
Encapsulations are as specified in RFC1483 Multiprotocol Interconnect
|
|
over ATM. The 'autoconfig' value will recognize both VC Mux and LLC
|
|
formats. The 'aal5' and 'aal0' values are used for encapsulation
|
|
methods for transport of ATM frames and cells over IP and MPLS networks
|
|
when no encapsulation method is specified."
|
|
DEFVAL { rfc1483VcMux }
|
|
|
|
::= { juniAtmVcClassEntry 2 }
|
|
|
|
juniAtmVcClassVccServiceCategory OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ubr(0),
|
|
ubrPcr(1),
|
|
nrtVbr(2),
|
|
cbr(3),
|
|
rtVbr(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service category for this circuit:
|
|
ubr Unspecified Bit Rate (best effort).
|
|
ubrPcr Unspecified Bit Rate with Peak Cell Rate limit.
|
|
nrtVbr Non-RealTime Variable Bit Rate.
|
|
cbr Constant Bit Rate.
|
|
rtVbr Realtime Variable Bit Rate."
|
|
DEFVAL { ubr }
|
|
::= { juniAtmVcClassEntry 3 }
|
|
|
|
juniAtmVcClassVccPcr OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Peak Cell Rate, in kilobits per second (kbps), of this circuit.
|
|
|
|
This parameter is only required when juniAtmVcClassVccServiceCategory is
|
|
configured to have one of the following values:
|
|
ubrPcr
|
|
nrtVbr
|
|
cbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcClassEntry 4 }
|
|
|
|
juniAtmVcClassVccScr OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
UNITS "kbps"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sustained Cell Rate, in kilobits per second (kbps), of this circuit.
|
|
This parameter is only required when juniAtmVcClassVccServiceCategory
|
|
is configured to have the following value:
|
|
nrtVbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcClassEntry 5 }
|
|
|
|
|
|
juniAtmVcClassVccMbs OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16777215)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Burst Size, in cells, of this circuit.
|
|
This parameter is only required when juniAtmVcClassVccServiceCategory
|
|
is configured to have the following value:
|
|
nrtVbr
|
|
rtVbr "
|
|
DEFVAL { 0 }
|
|
::= { juniAtmVcClassEntry 6 }
|
|
|
|
juniAtmVcClassVccOamAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oamAdminStateDisabled(1),
|
|
oamAdminStateEnabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM VC integrity administrative state of the ATM VC associated
|
|
with this class."
|
|
DEFVAL { oamAdminStateDisabled }
|
|
::= { juniAtmVcClassEntry 7 }
|
|
|
|
juniAtmVcClassVccOamLoopbackFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OAM loopback frequency in seconds."
|
|
DEFVAL { 10 }
|
|
::= { juniAtmVcClassEntry 8 }
|
|
|
|
juniAtmVcClassVccOamUpCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive loopback cell responses to
|
|
receive before the ATM VC associated with this class is declared
|
|
up for connectivity verification."
|
|
DEFVAL { 3 }
|
|
::= { juniAtmVcClassEntry 9 }
|
|
|
|
juniAtmVcClassVccOamDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive loopback cell responses not
|
|
received before declaring the ATM VC associated with this class
|
|
as down for connectivity verification."
|
|
DEFVAL { 5 }
|
|
::= { juniAtmVcClassEntry 10 }
|
|
|
|
juniAtmVcClassVccOamRetryFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the frequency (in seconds) to transmit loopback cells
|
|
when verifying the ATM VC operational state associated with this
|
|
class (up or down) for connectivity verification."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmVcClassEntry 11 }
|
|
|
|
juniAtmVcClassVccOamAlarmDownCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..60)
|
|
UNITS "cells"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the number of successive alarm (AIS or RDI) cells to
|
|
receive before declaring the ATM VC associated with class as down."
|
|
DEFVAL { 1 }
|
|
::= { juniAtmVcClassEntry 12 }
|
|
|
|
juniAtmVcClassVccOamAlarmClearTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (3..60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies how long to wait (in seconds) before declaring the ATM VC
|
|
associated with class as up after it has stopped receiving alarm cells."
|
|
DEFVAL { 3 }
|
|
::= { juniAtmVcClassEntry 13 }
|
|
|
|
|
|
juniAtmVcClassVccInverseArp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables the inverse ARP protocol on the ATM VC associated with this
|
|
class; true(1) enables the protocol, false(2) disables it."
|
|
::= { juniAtmVcClassEntry 14 }
|
|
|
|
juniAtmVcClassVccInverseArpRefresh OBJECT-TYPE
|
|
SYNTAX Integer32 (0..60)
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The refresh rate in minutes between inverse ARP protocol messages."
|
|
::= { juniAtmVcClassEntry 15 }
|
|
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Notification control objects
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- No global notification controls are defined. Placeholder follows.
|
|
-- juniAtmTrapControl OBJECT IDENTIFIER ::= { juniAtmMIB 2 }
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Notifications
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- The following two OBJECT IDENTIFIERS are used to define SNMPv2
|
|
-- Notifications that are easily translated into SNMPv1 Traps.
|
|
|
|
juniAtmTraps OBJECT IDENTIFIER ::= { juniAtmMIB 3 }
|
|
juniAtmTrapPrefix OBJECT IDENTIFIER ::= { juniAtmTraps 0 }
|
|
|
|
juniAtmVpPingTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
atmfM4VpTestId,
|
|
atmfM4VpTestType,
|
|
atmfM4VpTestResult,
|
|
juniAtmVpPingProbeCount,
|
|
juniAtmVpPingSentProbes,
|
|
juniAtmVpPingProbeResponses,
|
|
juniAtmVpPingMinRtt,
|
|
juniAtmVpPingMaxRtt,
|
|
juniAtmVpPingAverageRtt,
|
|
atmfM4VpTestCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated at the completion of a AtmfM4VpTest when the corresponding
|
|
juniAtmVpPingCtlTrapGeneration object has the testCompletion(0) bit
|
|
set."
|
|
::= { juniAtmTrapPrefix 1 }
|
|
|
|
juniAtmVcPingTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
atmfM4VcTestId,
|
|
atmfM4VcTestType,
|
|
atmfM4VcTestResult,
|
|
juniAtmVcPingProbeCount,
|
|
juniAtmVcPingSentProbes,
|
|
juniAtmVcPingProbeResponses,
|
|
juniAtmVcPingMinRtt,
|
|
juniAtmVcPingMaxRtt,
|
|
juniAtmVcPingAverageRtt,
|
|
atmfM4VcTestCode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated at the completion of a AtmfM4VcTest when the corresponding
|
|
juniAtmVcPingCtlTrapGeneration object has the testCompletion(0) bit
|
|
set."
|
|
::= { juniAtmTrapPrefix 2 }
|
|
|
|
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
-- Conformance information
|
|
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
|
|
juniAtmConformance OBJECT IDENTIFIER ::= { juniAtmMIB 4 }
|
|
juniAtmCompliances OBJECT IDENTIFIER ::= { juniAtmConformance 1 }
|
|
juniAtmGroups OBJECT IDENTIFIER ::= { juniAtmConformance 2 }
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
juniAtmCompliance MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when support was added for NBMA
|
|
map lists and ATM ping."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
::= { juniAtmCompliances 1 } -- JUNOSe 3.0
|
|
|
|
juniAtmCompliance2 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when support was added for
|
|
traffic shapping on VCC subinterfaces."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup2,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup2,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
::= { juniAtmCompliances 2 } -- JUNOSe 3.2
|
|
|
|
juniAtmCompliance3 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when support was added for
|
|
connection admission control (CAC)."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup2,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup2,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
::= { juniAtmCompliances 3 } -- JUNOSe 3.3
|
|
|
|
juniAtmCompliance4 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when ATM SVC, CAC used
|
|
bandwidth and sub-interface address objects were added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup3,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup2,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
::= { juniAtmCompliances 4 } -- JUNOSe 3.4
|
|
|
|
juniAtmCompliance5 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when CAC recieve bandwith and
|
|
E164 public addressing support was added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup4,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup3,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
::= { juniAtmCompliances 5 } -- JUNOSe 4.0
|
|
|
|
juniAtmCompliance6 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when F4 flow OAM circuit config
|
|
and stats tables were added to the Juniper ATM MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup5,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup4,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2 }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
::= { juniAtmCompliances 6 } -- JUNOSe 4.1
|
|
|
|
juniAtmCompliance7 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when the juniAtmLocationGroup
|
|
was added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup6,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup4,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
::= { juniAtmCompliances 7 } -- JUNOSe 5.1
|
|
|
|
juniAtmCompliance8 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when support was added to
|
|
export the subinterface description to the line cards."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup6,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup4,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
::= { juniAtmCompliances 8 } -- JUNOSe 5.2
|
|
|
|
juniAtmCompliance9 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement was obsoleted when the juniAtmMartiniGroup was
|
|
added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup6,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup5,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
::= { juniAtmCompliances 9 } -- JUNOSe 5.3
|
|
|
|
juniAtmCompliance10 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when
|
|
juniAtmIfCacAvailableBandwidthRx, juniAtmIfE164Autoconversion,
|
|
juniAtmIfE164Gateway, and juniAtmIfE164OneToOneAddrTrans were
|
|
deprecated."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup6,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup5,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
GROUP juniAtmMartiniGroup
|
|
DESCRIPTION
|
|
"The juniAtmMartiniGroup is mandatory only for entities that
|
|
support ATM Martini cell aggregation configuration"
|
|
::= { juniAtmCompliances 10 } -- JUNOSe 6.0
|
|
|
|
juniAtmCompliance11 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete compliance statement for entities which implement the Juniper
|
|
ATM MIB. This statement became obsolete when juniAtmGroup8 was
|
|
added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup7,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup5,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
GROUP juniAtmMartiniGroup
|
|
DESCRIPTION
|
|
"The juniAtmMartiniGroup is mandatory only for entities that
|
|
support ATM Martini cell aggregation configuration"
|
|
::= { juniAtmCompliances 11 } -- JUNOSe 6.1
|
|
|
|
juniAtmCompliance12 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the Juniper ATM
|
|
MIB. This statement became obsolete when juniAtmVpStatsGroup was added."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup8,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup5,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
GROUP juniAtmMartiniGroup
|
|
DESCRIPTION
|
|
"The juniAtmMartiniGroup is mandatory only for entities that
|
|
support ATM Martini cell aggregation configuration"
|
|
::= { juniAtmCompliances 12 } -- JUNOSe 7.0
|
|
|
|
juniAtmCompliance13 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the Juniper ATM
|
|
MIB. This statement became obsolete when SVC support was removed."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup8,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup6,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup2,
|
|
juniAtmVpStatsGroup }
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
GROUP juniAtmMartiniGroup
|
|
DESCRIPTION
|
|
"The juniAtmMartiniGroup is mandatory only for entities that
|
|
support ATM Martini cell aggregation configuration"
|
|
::= { juniAtmCompliances 13 } -- JUNOSe 7.1
|
|
|
|
juniAtmCompliance14 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement the Juniper ATM
|
|
MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
juniAtmGroup9,
|
|
juniAtmAal5Group,
|
|
juniAtmSubIfGroup7,
|
|
juniAtmVpPingControlGroup,
|
|
juniAtmVcPingControlGroup,
|
|
juniAtmPingTrapGroup,
|
|
juniAtmSvcGroup2,
|
|
juniAtmF4OamCircuitGroup2,
|
|
juniAtmVpStatsGroup,
|
|
juniAtmVcClassGroup}
|
|
GROUP juniAtmVpTunnelGroup
|
|
DESCRIPTION
|
|
"The juniAtmVpTunnelGroup is mandatory only for entities that
|
|
support a VP Tunnel functionality."
|
|
GROUP juniAtmNbmaMapGroup
|
|
DESCRIPTION
|
|
"The juniAtmNbmaMapGroup is mandatory only for entities that
|
|
support NBMA interfaces over ATM."
|
|
GROUP juniAtmTrafficShapingGroup
|
|
DESCRIPTION
|
|
"The juniAtmTrafficShapingGroup is mandatory only for entities
|
|
that support ATM traffic shaping."
|
|
GROUP juniAtmPnniGroup
|
|
DESCRIPTION
|
|
"The juniAtmPnniGroup is mandatory only for entities that
|
|
support PNNI routing for ATM networks."
|
|
GROUP juniAtmLocationGroup
|
|
DESCRIPTION
|
|
"The juniAtmLocationGroup is mandatory only for entities that
|
|
support slot and port interface location information"
|
|
GROUP juniAtmMartiniGroup
|
|
DESCRIPTION
|
|
"The juniAtmMartiniGroup is mandatory only for entities that
|
|
support ATM Martini cell aggregation configuration"
|
|
GROUP juniAtmVcClassGroup
|
|
DESCRIPTION
|
|
"The juniAtmVcClassGroup is mandatory only for entities that
|
|
support ATM VC class configuration"
|
|
::= { juniAtmCompliances 14 } -- JUNOSe 7.3
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
juniAtmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when the
|
|
juniAtmIfMapGroup object was added."
|
|
::= { juniAtmGroups 1 } -- JUNOSe 3.0
|
|
|
|
juniAtmAal5Group OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmAal5NextIfIndex,
|
|
|
|
juniAtmAal5IfRowStatus,
|
|
juniAtmAal5IfLowerIfIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of AAL5 interfaces in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 2 } -- JUNOSe 3.0
|
|
|
|
juniAtmSubIfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product. This group became obsolete when
|
|
juniAtmSubIfNbma, juniAtmSubIfInverseArp, and
|
|
juniAtmSubIfInverseArpRefresh were added."
|
|
::= { juniAtmGroups 3 } -- JUNOSe 3.0
|
|
|
|
juniAtmVpTunnelGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmVpTunnelKbps,
|
|
juniAtmVpTunnelRowStatus,
|
|
juniAtmVpTunnelServiceCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of VP tunnels in a Juniper
|
|
product."
|
|
::= { juniAtmGroups 4 } -- JUNOSe 3.0
|
|
|
|
juniAtmNbmaMapGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNbmaMapIpAddress,
|
|
juniAtmNbmaMapVpi,
|
|
juniAtmNbmaMapVci,
|
|
juniAtmNbmaMapIfIndex,
|
|
juniAtmNbmaMapBroadcast,
|
|
juniAtmNbmaMapRowStatus,
|
|
juniAtmNbmaMapListRowStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object providing management of NBMA in a Juniper
|
|
product."
|
|
::= { juniAtmGroups 5 } -- JUNOSe 3.2
|
|
|
|
juniAtmSubIfGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product. This group became obsolete when
|
|
juniAtmSubIfAddress was added."
|
|
::= { juniAtmGroups 6 } -- JUNOSe 3.2
|
|
|
|
juniAtmVpPingControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmVpPingProbeCount,
|
|
juniAtmVpPingTimeOut,
|
|
juniAtmVpPingCtlTrapGeneration,
|
|
juniAtmVpPingSentProbes,
|
|
juniAtmVpPingProbeResponses,
|
|
juniAtmVpPingStartTime,
|
|
juniAtmVpPingMinRtt,
|
|
juniAtmVpPingMaxRtt,
|
|
juniAtmVpPingAverageRtt }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object providing management of ATM VPL Ping testing in
|
|
a Juniper product."
|
|
::= { juniAtmGroups 7 } -- JUNOSe 3.2
|
|
|
|
juniAtmVcPingControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmVcPingProbeCount,
|
|
juniAtmVcPingTimeOut,
|
|
juniAtmVcPingCtlTrapGeneration,
|
|
juniAtmVcPingSentProbes,
|
|
juniAtmVcPingProbeResponses,
|
|
juniAtmVcPingStartTime,
|
|
juniAtmVcPingMinRtt,
|
|
juniAtmVcPingMaxRtt,
|
|
juniAtmVcPingAverageRtt }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of object providing management of ATM VCL Ping testing in
|
|
a Juniper product."
|
|
::= { juniAtmGroups 8 } -- JUNOSe 3.2
|
|
|
|
juniAtmPingTrapGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
juniAtmVpPingTestCompleted,
|
|
juniAtmVcPingTestCompleted }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of notifications supporting ATM Ping testing in a Juniper
|
|
product."
|
|
::= { juniAtmGroups 9 } -- JUNOSe 3.2
|
|
|
|
juniAtmGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfOamCellFilter,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
juniAtmIfCapabilityOamCellFilter }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when support was
|
|
added for connection admission control (CAC)."
|
|
::= { juniAtmGroups 10 } -- JUNOSe 3.2
|
|
|
|
juniAtmTrafficShapingGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfVccTrafficShapingCdvt,
|
|
juniAtmSubIfVccTrafficShapingClp0,
|
|
juniAtmSubIfVccTrafficShapingTagging,
|
|
juniAtmSubIfVccTrafficShapingPoliceObserve,
|
|
juniAtmSubIfVccTrafficShapingPacketShaping }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM traffic shaping in
|
|
a Juniper product."
|
|
::= { juniAtmGroups 11 } -- JUNOSe 3.3
|
|
|
|
juniAtmGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfOamCellFilter,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
juniAtmIfCapabilityOamCellFilter }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when support was added
|
|
for connection admission control (CAC) used bandwidth."
|
|
::= { juniAtmGroups 12 } -- JUNOSe 3.4
|
|
|
|
juniAtmGroup4 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfOamCellFilter,
|
|
juniAtmIfCacUsedBandwidthUpper,
|
|
juniAtmIfCacUsedBandwidthLower,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
juniAtmIfCapabilityOamCellFilter }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when CAC recieve
|
|
bandwith and E164 public addressing objects were added."
|
|
::= { juniAtmGroups 13 } -- JUNOSe 4.0
|
|
|
|
juniAtmSvcGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmIfSvcSignallingVpi,
|
|
juniAtmIfSvcSignallingVci,
|
|
juniAtmIfSvcSignallingVcd,
|
|
juniAtmIfSvcSignallingAdminStatus,
|
|
|
|
juniAtmSubIfSvcRowStatus,
|
|
juniAtmSubIfSvcConfigDestAtmAddress,
|
|
juniAtmSubIfSvcConfigCircuitType,
|
|
juniAtmSubIfSvcConfigServiceCategory,
|
|
juniAtmSubIfSvcConfigPcr,
|
|
juniAtmSubIfSvcConfigScr,
|
|
juniAtmSubIfSvcConfigMbs,
|
|
juniAtmSubIfSvcConfigCdvt,
|
|
juniAtmSubIfSvcConfigClp0,
|
|
juniAtmSubIfSvcConfigTagging,
|
|
juniAtmSubIfSvcConfigObserve,
|
|
juniAtmSubIfSvcConfigPacketDiscard }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM SVC
|
|
interfaces in a Juniper product. This group became obsolete when E164
|
|
public addressing support was added."
|
|
::= { juniAtmGroups 14 } -- JUNOSe 4.0
|
|
|
|
juniAtmSubIfGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
juniAtmSubIfAddress,
|
|
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product. This group became obsolete when
|
|
juniAtmSubIfMtu was added."
|
|
::= { juniAtmGroups 15 } -- JUNOSe 4.0
|
|
|
|
juniAtmGroup5 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfCacAvailableBandwidthRx,
|
|
juniAtmIfE164Autoconversion,
|
|
juniAtmIfE164Gateway,
|
|
juniAtmIfE164OneToOneAddrTrans,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when ATM VP
|
|
description support was added."
|
|
::= { juniAtmGroups 16 } -- JUNOSe 4.1
|
|
|
|
juniAtmSvcGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmIfSvcSignallingVpi,
|
|
juniAtmIfSvcSignallingVci,
|
|
juniAtmIfSvcSignallingVcd,
|
|
juniAtmIfSvcSignallingAdminStatus,
|
|
|
|
juniAtmSubIfSvcRowStatus,
|
|
juniAtmSubIfSvcConfigDestAtmAddress,
|
|
juniAtmSubIfSvcConfigCircuitType,
|
|
juniAtmSubIfSvcConfigServiceCategory,
|
|
juniAtmSubIfSvcConfigPcr,
|
|
juniAtmSubIfSvcConfigScr,
|
|
juniAtmSubIfSvcConfigMbs,
|
|
juniAtmSubIfSvcConfigClp0,
|
|
juniAtmSubIfSvcConfigTagging,
|
|
juniAtmSubIfSvcConfigPacketDiscard,
|
|
juniAtmSubIfSvcConfigDestE164Address }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM SVC interfaces in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 17 } -- JUNOSe 4.1
|
|
|
|
juniAtmPnniGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmIfPnniRccVpi,
|
|
juniAtmIfPnniRccVci,
|
|
juniAtmIfPnniRccVcd,
|
|
juniAtmIfPnniRccAdminStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of PNNI Routing Control
|
|
Channels in a Juniper product."
|
|
::= { juniAtmGroups 18 } -- JUNOSe 4.1
|
|
|
|
juniAtmSubIfGroup4 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
juniAtmSubIfAddress,
|
|
juniAtmSubIfMtu,
|
|
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product. This group became obsolete when
|
|
support was added to export the subinterface description to the line
|
|
cards."
|
|
::= { juniAtmGroups 19 } -- JUNOSe 4.1
|
|
|
|
juniAtmF4OamCircuitGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- End-to-end configs
|
|
juniAtmOamF4FlowEndToEndLoopbackTimer,
|
|
juniAtmOamF4FlowEndToEndCCSink,
|
|
juniAtmOamF4FlowEndToEndCCSource,
|
|
juniAtmOamF4FlowEndToEndRowStatus,
|
|
-- Segment configs
|
|
juniAtmOamF4FlowSegmentCCSink,
|
|
juniAtmOamF4FlowSegmentCCSource,
|
|
juniAtmOamF4FlowSegmentRowStatus,
|
|
|
|
-- End-to-end stats
|
|
juniAtmF4FlowInOamEndAisCells,
|
|
juniAtmF4FlowInOamEndRdiCells,
|
|
juniAtmF4FlowInOamEndCCCells,
|
|
juniAtmF4FlowInOamEndCCActDeActCells,
|
|
juniAtmF4FlowInOamEndLoopbackCells,
|
|
juniAtmF4FlowOutEndRdiCells,
|
|
juniAtmF4FlowOutEndCCCells,
|
|
juniAtmF4FlowOutEndCCActDeActCells,
|
|
juniAtmF4FlowOutEndToEndLoopbackCells,
|
|
juniAtmF4FlowEndActualLoopbackFreq,
|
|
juniAtmF4FlowEndLastTimeChanged,
|
|
juniAtmF4FlowOamEndVpOperationState,
|
|
juniAtmF4FlowOamEndVpAdminState,
|
|
juniAtmF4FlowEndInOamCells,
|
|
juniAtmF4FlowEndOutOamCells,
|
|
juniAtmF4FlowEndInOamCellsDropped,
|
|
-- Segment stats
|
|
juniAtmF4FlowInOamSegmentAisCells,
|
|
juniAtmF4FlowInOamSegmentRdiCells,
|
|
juniAtmF4FlowInOamSegmentCCCells,
|
|
juniAtmF4FlowInOamSegmentCCActDeActCells,
|
|
juniAtmF4FlowInOamSegmentLoopbackCells,
|
|
juniAtmF4FlowOutSegmentRdiCells,
|
|
juniAtmF4FlowOutSegmentCCCells,
|
|
juniAtmF4FlowOutSegmentCCActDeActCells,
|
|
juniAtmF4FlowOutSegmentLoopbackCells,
|
|
juniAtmF4FlowSegmentLastTimeChanged,
|
|
juniAtmF4FlowOamSegmentVpOperationState,
|
|
juniAtmF4FlowOamSegmentVpAdminState,
|
|
juniAtmF4FlowSegmentInOamCells,
|
|
juniAtmF4FlowSegmentOutOamCells,
|
|
juniAtmF4FlowSegmentInOamCellsDropped }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM F4 flow OAM
|
|
circuits in a Juniper product."
|
|
::= { juniAtmGroups 20 } -- JUNOSe 4.1
|
|
|
|
juniAtmGroup6 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfCacAvailableBandwidthRx,
|
|
juniAtmIfE164Autoconversion,
|
|
juniAtmIfE164Gateway,
|
|
juniAtmIfE164OneToOneAddrTrans,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
|
|
juniAtmVpDescription,
|
|
juniAtmBulkCircuitsNameRowStatus,
|
|
juniAtmBulkCircuitsNameId,
|
|
juniAtmBulkCircuitsIdName,
|
|
juniAtmBulkCircuitsIdNextInstance,
|
|
juniAtmBulkCircuitsRowStatus,
|
|
juniAtmBulkCircuitsMinVpi,
|
|
juniAtmBulkCircuitsMaxVpi,
|
|
juniAtmBulkCircuitsMinVci,
|
|
juniAtmBulkCircuitsMaxVci }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM interfaces
|
|
in a Juniper product. This group became obsolete when bulk-configuration
|
|
profile override support was added."
|
|
::= { juniAtmGroups 21 } -- JUNOSe 5.1
|
|
|
|
juniAtmLocationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfLocationType,
|
|
juniAtmSubIfLocationIfIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing interface location information in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 22 } -- JUNOSe 5.2
|
|
|
|
juniAtmSubIfGroup5 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
juniAtmSubIfAddress,
|
|
juniAtmSubIfMtu,
|
|
juniAtmSubIfAdvisoryRxSpeed,
|
|
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells,
|
|
|
|
juniAtmSubIfDescriptionExport }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product."
|
|
::= { juniAtmGroups 23 }
|
|
|
|
juniAtmMartiniGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmMartiniTimeoutTimerValue,
|
|
|
|
juniAtmSubIfMartiniMaxCellsPerPacket,
|
|
juniAtmSubIfMartiniTimeoutTimerId }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing ATM Martini cell aggregation
|
|
configuration."
|
|
::= { juniAtmGroups 24 }
|
|
|
|
juniAtmGroup7 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfCacAvailableBandwidthRx,
|
|
juniAtmIfE164Autoconversion,
|
|
juniAtmIfE164Gateway,
|
|
juniAtmIfE164OneToOneAddrTrans,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
|
|
juniAtmVpDescription,
|
|
juniAtmBulkCircuitsNameRowStatus,
|
|
juniAtmBulkCircuitsNameId,
|
|
juniAtmBulkCircuitsIdName,
|
|
juniAtmBulkCircuitsIdNextInstance,
|
|
juniAtmBulkCircuitsRowStatus,
|
|
juniAtmBulkCircuitsMinVpi,
|
|
juniAtmBulkCircuitsMaxVpi,
|
|
juniAtmBulkCircuitsMinVci,
|
|
juniAtmBulkCircuitsMaxVci,
|
|
juniAtmBulkCircuitsAdminState,
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitRowStatus,
|
|
juniAtmProfileOverrideAssignIfCircuitProfileId,
|
|
juniAtmProfileOverrideAssignIfCircuitOperStatus }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
interfaces in a Juniper product."
|
|
::= { juniAtmGroups 25 } -- JUNOSe 6.1
|
|
|
|
juniAtmGroup8 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
|
|
juniAtmVpDescription,
|
|
juniAtmBulkCircuitsNameRowStatus,
|
|
juniAtmBulkCircuitsNameId,
|
|
juniAtmBulkCircuitsIdName,
|
|
juniAtmBulkCircuitsIdNextInstance,
|
|
juniAtmBulkCircuitsRowStatus,
|
|
juniAtmBulkCircuitsMinVpi,
|
|
juniAtmBulkCircuitsMaxVpi,
|
|
juniAtmBulkCircuitsMinVci,
|
|
juniAtmBulkCircuitsMaxVci,
|
|
juniAtmBulkCircuitsAdminState,
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitRowStatus,
|
|
juniAtmProfileOverrideAssignIfCircuitProfileId,
|
|
juniAtmProfileOverrideAssignIfCircuitOperStatus }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM interfaces in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 26 } -- JUNOSe 7.0
|
|
|
|
|
|
juniAtmVpStatsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmVpStatsInCells,
|
|
juniAtmVpStatsInPackets,
|
|
juniAtmVpStatsInPacketOctets,
|
|
juniAtmVpStatsOutCells,
|
|
juniAtmVpStatsOutPackets,
|
|
juniAtmVpStatsOutPacketOctets,
|
|
juniAtmVpStatsInPacketErrors,
|
|
juniAtmVpStatsOutPacketErrors,
|
|
juniAtmVpStatsInPacketDiscards,
|
|
juniAtmVpStatsInPacketOctetDiscards,
|
|
juniAtmVpStatsInPacketUnknownProtocol,
|
|
juniAtmVpStatsCrcErrors,
|
|
juniAtmVpStatsSarTimeouts,
|
|
juniAtmVpStatsOverSizedPackets}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing ATM VP level statistics."
|
|
::= { juniAtmGroups 27 } -- JUNOSe 7.1
|
|
|
|
juniAtmSubIfGroup6 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
juniAtmSubIfAddress,
|
|
juniAtmSubIfMtu,
|
|
juniAtmSubIfAdvisoryRxSpeed,
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds,
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps,
|
|
juniAtmCircuitOamUpCount,
|
|
juniAtmCircuitOamDownCount,
|
|
juniAtmCircuitOamRetryFrequency,
|
|
juniAtmCircuitOamAlarmDownCount,
|
|
juniAtmCircuitOamAlarmClearTimeout,
|
|
juniAtmSubIfDescriptionExport }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Obsolete collection of objects providing management of ATM
|
|
subinterfaces in a Juniper product. This group became obsolete
|
|
when ATM SVC support was removed."
|
|
|
|
::= { juniAtmGroups 28 } -- JUNOSe 7.1
|
|
|
|
juniAtmF4OamCircuitGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmOamF4FlowEndToEndLoopbackTimer,
|
|
juniAtmOamF4FlowEndToEndCCSink,
|
|
juniAtmOamF4FlowEndToEndCCSource,
|
|
juniAtmOamF4FlowEndToEndRowStatus,
|
|
juniAtmOamF4FlowSegmentCCSink,
|
|
juniAtmOamF4FlowSegmentCCSource,
|
|
juniAtmOamF4FlowSegmentRowStatus,
|
|
juniAtmF4FlowInOamEndAisCells,
|
|
juniAtmF4FlowInOamEndRdiCells,
|
|
juniAtmF4FlowInOamEndCCCells,
|
|
juniAtmF4FlowInOamEndCCActDeActCells,
|
|
juniAtmF4FlowInOamEndLoopbackCells,
|
|
juniAtmF4FlowOutEndRdiCells,
|
|
juniAtmF4FlowOutEndCCCells,
|
|
juniAtmF4FlowOutEndCCActDeActCells,
|
|
juniAtmF4FlowOutEndToEndLoopbackCells,
|
|
juniAtmF4FlowEndActualLoopbackFreq,
|
|
juniAtmF4FlowEndLastTimeChanged,
|
|
juniAtmF4FlowOamEndVpOperationState,
|
|
juniAtmF4FlowOamEndVpAdminState,
|
|
juniAtmF4FlowEndInOamCells,
|
|
juniAtmF4FlowEndOutOamCells,
|
|
juniAtmF4FlowEndInOamCellsDropped,
|
|
juniAtmF4FlowInOamSegmentAisCells,
|
|
juniAtmF4FlowInOamSegmentRdiCells,
|
|
juniAtmF4FlowInOamSegmentCCCells,
|
|
juniAtmF4FlowInOamSegmentCCActDeActCells,
|
|
juniAtmF4FlowInOamSegmentLoopbackCells,
|
|
juniAtmF4FlowOutSegmentRdiCells,
|
|
juniAtmF4FlowOutSegmentCCCells,
|
|
juniAtmF4FlowOutSegmentCCActDeActCells,
|
|
juniAtmF4FlowOutSegmentLoopbackCells,
|
|
juniAtmF4FlowSegmentLastTimeChanged,
|
|
juniAtmF4FlowOamSegmentVpOperationState,
|
|
juniAtmF4FlowOamSegmentVpAdminState,
|
|
juniAtmF4FlowSegmentInOamCells,
|
|
juniAtmF4FlowSegmentOutOamCells,
|
|
juniAtmF4FlowSegmentInOamCellsDropped,
|
|
juniAtmF4FlowEndToEndInLoopbackCmds,
|
|
juniAtmF4FlowEndToEndInLoopbackRsps,
|
|
juniAtmF4FlowSegmentInLoopbackCmds,
|
|
juniAtmF4FlowSegmentInLoopbackRsps,
|
|
juniAtmF4FlowEndToEndOutLoopbackCmds,
|
|
juniAtmF4FlowEndToEndOutLoopbackRsps,
|
|
juniAtmF4FlowSegmentOutLoopbackCmds,
|
|
juniAtmF4FlowSegmentOutLoopbackRsps }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM F4 flow OAM
|
|
circuits in a Juniper product."
|
|
::= { juniAtmGroups 29 } -- JUNOSe 7.1
|
|
|
|
juniAtmGroup9 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmNextIfIndex,
|
|
juniAtmIfRowStatus,
|
|
juniAtmIfLowerIfIndex,
|
|
juniAtmIfIlmiVpi,
|
|
juniAtmIfIlmiVci,
|
|
juniAtmIfIlmiVcd,
|
|
juniAtmIfIlmiPollFrequency,
|
|
juniAtmIfIlmiAdminState,
|
|
juniAtmIfUniVersion,
|
|
juniAtmIfOamCellRxAdminState,
|
|
juniAtmIfInCells,
|
|
juniAtmIfOutCells,
|
|
juniAtmIfVcCount,
|
|
juniAtmIfMapGroup,
|
|
juniAtmIfCacAdminState,
|
|
juniAtmIfCacUbrWeight,
|
|
juniAtmIfCacSubscriptionBandwidth,
|
|
juniAtmIfCacAvailableBandwidth,
|
|
juniAtmIfAssociatedVcClassId,
|
|
|
|
juniAtmPvcStatsInCells,
|
|
juniAtmPvcStatsInCellOctets,
|
|
juniAtmPvcStatsInPackets,
|
|
juniAtmPvcStatsInPacketOctets,
|
|
juniAtmPvcStatsOutCells,
|
|
juniAtmPvcStatsOutCellOctets,
|
|
juniAtmPvcStatsOutPackets,
|
|
juniAtmPvcStatsOutPacketOctets,
|
|
juniAtmPvcStatsInCellErrors,
|
|
juniAtmPvcStatsinPacketErrors,
|
|
juniAtmPvcStatsOutCellErrors,
|
|
juniAtmPvcStatsOutPacketErrors,
|
|
juniAtmPvcStatsInPacketDiscards,
|
|
juniAtmPvcStatsInPacketOctetDiscards,
|
|
juniAtmPvcStatsInPacketUnknownProtocol,
|
|
|
|
juniAtmIfCapabilityTrafficShaping,
|
|
juniAtmIfCapabilityOam,
|
|
juniAtmIfCapabilityDefaultVcPerVp,
|
|
juniAtmIfCapabilityNumVpiVciBits,
|
|
juniAtmIfCapabilityMaxVcd,
|
|
juniAtmIfCapabilityMaxVpi,
|
|
juniAtmIfCapabilityMaxVci,
|
|
|
|
juniAtmVpDescription,
|
|
juniAtmBulkCircuitsNameRowStatus,
|
|
juniAtmBulkCircuitsNameId,
|
|
juniAtmBulkCircuitsIdName,
|
|
juniAtmBulkCircuitsIdNextInstance,
|
|
juniAtmBulkCircuitsRowStatus,
|
|
juniAtmBulkCircuitsMinVpi,
|
|
juniAtmBulkCircuitsMaxVpi,
|
|
juniAtmBulkCircuitsMinVci,
|
|
juniAtmBulkCircuitsMaxVci,
|
|
juniAtmBulkCircuitsAdminState,
|
|
|
|
juniAtmProfileOverrideAssignIfCircuitRowStatus,
|
|
juniAtmProfileOverrideAssignIfCircuitProfileId,
|
|
juniAtmProfileOverrideAssignIfCircuitOperStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM interfaces in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 30 } -- JUNOSe 7.3
|
|
|
|
juniAtmSubIfGroup7 OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmSubIfNextIfIndex,
|
|
juniAtmSubIfRowStatus,
|
|
juniAtmSubIfDistinguisher,
|
|
juniAtmSubIfLowerIfIndex,
|
|
juniAtmSubIfNbma,
|
|
juniAtmSubIfAddress,
|
|
juniAtmSubIfMtu,
|
|
juniAtmSubIfAdvisoryRxSpeed,
|
|
juniAtmSubIfAssociatedVcClassId,
|
|
juniAtmSubIfVccRowStatus,
|
|
juniAtmSubIfVccVcd,
|
|
juniAtmSubIfVccType,
|
|
juniAtmSubIfVccServiceCategory,
|
|
juniAtmSubIfVccPcr,
|
|
juniAtmSubIfVccScr,
|
|
juniAtmSubIfVccMbs,
|
|
juniAtmSubIfInverseArp,
|
|
juniAtmSubIfInverseArpRefresh,
|
|
juniAtmSubIfVccAssociatedVcClassId,
|
|
juniAtmCircuitOamAdminStatus,
|
|
juniAtmCircuitOamLoopbackOperStatus,
|
|
juniAtmCircuitVcOamOperStatus,
|
|
juniAtmCircuitOamLoopbackFrequency,
|
|
juniAtmCircuitInOamF5Cells,
|
|
juniAtmCircuitInOamCellsDropped,
|
|
juniAtmCircuitOutOamF5Cells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitInOamF5AisCells,
|
|
juniAtmCircuitInOamF5RdiCells,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCells,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCells,
|
|
juniAtmCircuitOutOamF5RdiCells,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackCmds,
|
|
juniAtmCircuitInOamF5EndToEndLoopbackRsps,
|
|
juniAtmCircuitInOamF5SegmentLoopbackCmds,
|
|
juniAtmCircuitInOamF5SegmentLoopbackRsps,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackCmds,
|
|
juniAtmCircuitOutOamF5EndToEndLoopbackRsps,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackCmds,
|
|
juniAtmCircuitOutOamF5SegmentLoopbackRsps,
|
|
juniAtmCircuitOamUpCount,
|
|
juniAtmCircuitOamDownCount,
|
|
juniAtmCircuitOamRetryFrequency,
|
|
juniAtmCircuitOamAlarmDownCount,
|
|
juniAtmCircuitOamAlarmClearTimeout,
|
|
juniAtmSubIfDescriptionExport }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM subinterfaces in a
|
|
Juniper product."
|
|
::= { juniAtmGroups 31 } -- JUNOSe 7.3
|
|
|
|
juniAtmVcClassGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
juniAtmVcClassName,
|
|
juniAtmVcClassNameRowStatus,
|
|
juniAtmVcClassNameId,
|
|
juniAtmVcClassIdName,
|
|
juniAtmVcClassVccType,
|
|
juniAtmVcClassVccServiceCategory,
|
|
juniAtmVcClassVccPcr,juniAtmVcClassVccScr,
|
|
juniAtmVcClassVccMbs,
|
|
juniAtmVcClassVccOamAdminStatus,
|
|
juniAtmVcClassVccOamLoopbackFrequency,
|
|
juniAtmVcClassVccOamUpCount,
|
|
juniAtmVcClassVccOamDownCount,
|
|
juniAtmVcClassVccOamRetryFrequency,
|
|
juniAtmVcClassVccOamAlarmDownCount,
|
|
juniAtmVcClassVccOamAlarmClearTimeout,
|
|
juniAtmVcClassVccInverseArp,
|
|
juniAtmVcClassVccInverseArpRefresh}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing management of ATM VC class in a
|
|
Juniper product." -- JUNOSe7.3
|
|
::= { juniAtmGroups 32 }
|
|
END
|