223 lines
7.2 KiB
Plaintext
223 lines
7.2 KiB
Plaintext
LINKSYS-PHY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: LINKSYS PHY MIB
|
|
-- Version: 7.38
|
|
-- Date: 10 Sep 2004
|
|
--
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI
|
|
ifIndex FROM IF-MIB
|
|
TimeStamp, DisplayString FROM SNMPv2-TC
|
|
rnd FROM LINKSYS-MIB
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
|
|
|
rlPhy MODULE-IDENTITY
|
|
LAST-UPDATED "200209300024Z" -- September 30, 2002
|
|
ORGANIZATION "Linksys Computer Communication Ltd."
|
|
CONTACT-INFO
|
|
"www.linksys.com/business/support"
|
|
DESCRIPTION
|
|
"The MIB module describes the private MIB for testing Layer1 interfaces supported
|
|
by Linksys's software and products."
|
|
REVISION "200209300024Z" -- September 30, 2002
|
|
DESCRIPTION
|
|
"Initial revision"
|
|
REVISION "200309210024Z" -- September 21, 2003
|
|
DESCRIPTION
|
|
"Added MODULE-IDENTITY and TEXTUAL-CONVENTION IMPORTS."
|
|
::= { rnd 90 }
|
|
|
|
|
|
RlPhyTestType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the test to perform."
|
|
SYNTAX INTEGER {
|
|
rlPhyTestTableNoTest(1),
|
|
rlPhyTestTableCableStatus(2),
|
|
rlPhyTestTableCableFault(3),
|
|
rlPhyTestTableCableLength(4),
|
|
rlPhyTestTableTransceiverTemp(5),
|
|
rlPhyTestTableTransceiverSupply(6),
|
|
rlPhyTestTableTxBias(7),
|
|
rlPhyTestTableTxOutput(8),
|
|
rlPhyTestTableRxOpticalPower(9),
|
|
rlPhyTestTableDataReady(10),
|
|
rlPhyTestTableLOS(11),
|
|
rlPhyTestTableTxFault(12),
|
|
rlPhyTestTableCableChannel1(13),
|
|
rlPhyTestTableCableChannel2(14),
|
|
rlPhyTestTableCableChannel3(15),
|
|
rlPhyTestTableCableChannel4(16),
|
|
rlPhyTestTableCablePolarity1(17),
|
|
rlPhyTestTableCablePolarity2(18),
|
|
rlPhyTestTableCablePolarity3(19),
|
|
rlPhyTestTableCablePolarity4(20),
|
|
rlPhyTestTableCablePairSkew1(21),
|
|
rlPhyTestTableCablePairSkew2(22),
|
|
rlPhyTestTableCablePairSkew3(23),
|
|
rlPhyTestTableCablePairSkew4(24)
|
|
}
|
|
|
|
rlPhyTest OBJECT IDENTIFIER ::= { rlPhy 1 }
|
|
|
|
rlPhyTestSetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPhyTestSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { rlPhyTest 1}
|
|
|
|
rlPhyTestSetEntry OBJECT-TYPE
|
|
SYNTAX RlPhyTestSetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for invoking tests on an interface."
|
|
INDEX {ifIndex }
|
|
::= { rlPhyTestSetTable 1 }
|
|
|
|
RlPhyTestSetEntry ::=
|
|
SEQUENCE {
|
|
rlPhyTestSetType RlPhyTestType
|
|
}
|
|
|
|
rlPhyTestSetType OBJECT-TYPE
|
|
SYNTAX RlPhyTestType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A control variable used to start operator initiated interface
|
|
tests.1 indicates that no test has been initiated. Only
|
|
operator initiated interface tests can be set to this variable."
|
|
::= { rlPhyTestSetEntry 1 }
|
|
|
|
rlPhyTestGetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPhyTestGetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { rlPhyTest 2 }
|
|
|
|
rlPhyTestGetEntry OBJECT-TYPE
|
|
SYNTAX RlPhyTestGetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing results of tests on an interface."
|
|
INDEX {ifIndex, rlPhyTestGetType}
|
|
::= { rlPhyTestGetTable 1 }
|
|
|
|
RlPhyTestGetEntry ::=
|
|
SEQUENCE {
|
|
rlPhyTestGetType RlPhyTestType,
|
|
rlPhyTestGetStatus INTEGER,
|
|
rlPhyTestGetResult INTEGER,
|
|
rlPhyTestGetUnits INTEGER,
|
|
rlPhyTestGetAlarm INTEGER,
|
|
rlPhyTestGetTimeStamp DisplayString
|
|
}
|
|
|
|
rlPhyTestGetType OBJECT-TYPE
|
|
SYNTAX RlPhyTestType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A control variable used to, 1 to indicate that this test can be
|
|
done on the specified port, 2 to initiate the test whenever the
|
|
user wishes"
|
|
::= { rlPhyTestGetEntry 1 }
|
|
|
|
rlPhyTestGetStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1), -- no test yet requested
|
|
success(2),
|
|
inProgress(3),
|
|
notSupported(4),
|
|
unAbleToRun(5), -- due to state of system
|
|
aborted(6),
|
|
failed(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object contains the status of the most recently
|
|
requested test for operator initiated tests or the value
|
|
none(1) if no tests have been requested since the last
|
|
reset. For non operator initiated tests the value is always
|
|
none(1).
|
|
Note that this facility provides no provision for saving
|
|
the results of one test when starting another, as could
|
|
be required if used by multiple managers concurrently."
|
|
::= { rlPhyTestGetEntry 2 }
|
|
|
|
rlPhyTestGetResult OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object holds the test result"
|
|
::= { rlPhyTestGetEntry 3 }
|
|
|
|
rlPhyTestGetUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
integer(1),
|
|
boolean(2),
|
|
downUP(3),
|
|
reverseNormal(4),
|
|
mdiMdix(5),
|
|
meter(6),
|
|
degree(7), -- Celsius
|
|
microVolt(8),
|
|
microOham(9),
|
|
microAmper(10),
|
|
microWatt(11),
|
|
millisecond(12),
|
|
alaskaPhyLength(13),
|
|
alaskaPhyStatus(14),
|
|
dbm(15),
|
|
decidbm(16),
|
|
milidbm(17),
|
|
abcd(18),
|
|
nanosecond(19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test result unit of measure. The units can be standard unit or special units
|
|
that are designed for special test.
|
|
|
|
The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
|
|
less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).
|
|
|
|
The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
|
|
4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
|
|
::= { rlPhyTestGetEntry 4 }
|
|
|
|
rlPhyTestGetAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notRelevant(1),
|
|
noAlarmSet(2),
|
|
lowWarning(3),
|
|
highWarning(4),
|
|
lowAlarm(5),
|
|
highAlarm(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object hold the Alarm for this Entry. only Test that have can have alarms
|
|
use this field, other holds the Value notRelevant(1) "
|
|
::= { rlPhyTestGetEntry 5 }
|
|
|
|
rlPhyTestGetTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in string (formated DD-MMM-YYYY HH:MM:SS e.g
|
|
14-Apr-2002 10:33:31)"
|
|
::= { rlPhyTestGetEntry 6 }
|
|
|
|
END
|