L-AM3440-A-Private DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Counter, Gauge
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215
Integer32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
OBJECT-TYPE
FROM RFC-1212;
--======================================================================--
-- General definition of Slot ID
GenSlotID ::= INTEGER {
no(0),
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
pw(18)
}
-- Chassis slot definition
ChassisSlot ::= INTEGER {
primary(1),
redundant(2),
slotA(3),
slotB(4),
slotC(5),
slotD(6),
slot1(7),
slot2(8),
slot3(9),
slot4(10),
slot5(11),
slot6(12),
slot7(13),
slot8(14),
slot9(15),
slot10(16),
slot11(17),
slot12(18)
}
-- General definition of Port ID
GenPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
port-9(9),
port-10(10),
port-11(11),
port-12(12),
port-13(13),
port-14(14),
port-15(15),
port-16(16),
port-17(17),
port-18(18),
port-19(19),
port-20(20),
port-21(21),
port-22(22),
port-23(23),
port-24(24),
port-25(25),
port-26(26),
port-27(27),
port-28(28),
port-29(29),
port-30(30),
port-31(31),
port-32(32),
port-33(33),
port-34(34),
port-35(35),
port-36(36),
port-37(37),
port-38(38),
port-39(39),
port-40(40),
port-41(41),
port-42(42),
port-43(43),
port-44(44),
port-45(45),
port-46(46),
port-47(47),
port-48(48),
port-49(49),
port-50(50),
port-51(51),
port-52(52),
port-53(53),
port-54(54),
port-55(55),
port-56(56),
port-57(57),
port-58(58),
port-59(59),
port-60(60),
port-61(61),
port-62(62),
port-63(63),
port-64(64),
ep1(101),
ep2(102),
cp1(103),
cp2(104),
gp1(121),
gp2(122),
gp3(123),
gp4(124),
gp5(125),
gp6(126),
gp7(127),
gp8(128),
gp9(129),
gp10(130),
gp11(131),
gp12(132),
gp13(133),
gp14(134),
gp15(135),
gp16(136),
gp17(137),
gp18(138),
gp19(139),
gp20(140),
gp21(141),
gp22(142),
gp23(143),
gp24(144),
gp25(145),
gp26(146),
gp27(147),
gp28(148),
gp29(149),
gp30(150),
gp31(151),
gp32(152),
gp33(153),
gp34(154),
gp35(155),
gp36(156),
gp37(157),
gp38(158),
gp39(159),
gp40(160),
gp41(161),
gp42(162),
none(254)
}
-- General definition of Alarm Port
AlarmPort ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
port-9(9),
port-10(10),
port-11(11),
port-12(12),
port-13(13),
port-14(14),
port-15(15),
port-16(16),
port-17(17),
port-18(18),
port-19(19),
port-20(20),
port-21(21),
port-22(22),
port-23(23),
port-24(24),
port-25(25),
port-26(26),
port-27(27),
port-28(28),
port-29(29),
port-30(30),
port-31(31),
port-32(32),
port-33(33),
port-34(34),
port-35(35),
port-36(36),
port-37(37),
port-38(38),
port-39(39),
port-40(40),
port-41(41),
port-42(42),
port-43(43),
port-44(44),
port-45(45),
port-46(46),
port-47(47),
port-48(48),
port-49(49),
port-50(50),
port-51(51),
port-52(52),
port-53(53),
port-54(54),
port-55(55),
port-56(56),
port-57(57),
port-58(58),
port-59(59),
port-60(60),
port-61(61),
port-62(62),
port-63(63),
port-64(64),
eth-1(101),
eth-2(102),
eth-3(103),
eth-4(104),
eth-5(105),
eth-6(106),
eth-7(107),
eth-8(108),
p1-1(111),
p1-2(112),
p1-3(113),
p2-1(114),
p2-2(115),
p2-3(116),
p3-1(117),
p3-2(118),
p3-3(119),
p4-1(120),
p4-2(121),
p4-3(122),
none(254)
}
-- General definition of Alarm Severity
AlarmSeverityDisp ::= INTEGER {
major(1),
critical(2),
minor(3),
indication(4),
clear(5),
na(6)
}
-- General definition of Alarm Link
AlarmLink ::= INTEGER {
ts01(1),
ts02(2),
ts03(3),
ts04(4),
ts05(5),
ts06(6),
ts07(7),
ts08(8),
ts09(9),
ts10(10),
ts11(11),
ts12(12),
ts13(13),
ts14(14),
ts15(15),
ts16(16),
ts17(17),
ts18(18),
ts19(19),
ts20(20),
ts21(21),
ts22(22),
ts23(23),
ts24(24),
ts25(25),
ts26(26),
ts27(27),
ts28(28),
ts29(29),
ts30(30),
ts31(31),
bundle-0(100),
bundle-1(101),
bundle-2(102),
bundle-3(103),
bundle-4(104),
bundle-5(105),
bundle-6(106),
bundle-7(107),
bundle-8(108),
bundle-9(109),
bundle-10(110),
bundle-11(111),
bundle-12(112),
bundle-13(113),
bundle-14(114),
bundle-15(115),
bundle-16(116),
bundle-17(117),
bundle-18(118),
bundle-19(119),
bundle-20(120),
bundle-21(121),
bundle-22(122),
bundle-23(123),
bundle-24(124),
bundle-25(125),
bundle-26(126),
bundle-27(127),
bundle-28(128),
bundle-29(129),
bundle-30(130),
bundle-31(131),
none(254)
}
-- General definition of Model Type
GenModelType ::= INTEGER {
empty(1),
fe1(2),
ft1(3),
v35(4),
x50(5),
dtu-10(6),
mdsl(7),
em(8),
dtu-6(9),
router(10),
fxs(11),
fxo(12),
afr-e1(14),
afr-t1(15),
magneto(16),
quad-e1(21),
quad-t1(22),
v35-b(23),
mdsl-a(24),
v35-a(25),
x21-a(26),
v36-a(27),
g703(28),
mquad-e1(29),
mquad-t1(30),
gshdsl-2(31),
gshdsl-4(32),
rs422-a(33),
dry-contact(34),
fom(35),
router-a(36),
eia530-rs449-a(37),
ls-optical(38),
ocudp(39),
oct-rt-b(40),
ts(41),
rs232-8(42),
qfxo(43),
qfxs(44),
q2wem(45),
q4wem(46),
conference(47),
tri-e1(48),
tri-t1(49),
sdte(50),
tdmoe(51),
oct-dbra(52),
socudp(53),
octDte(54),
plm(55),
eca(56),
rs232a(57),
abra(58),
tta(59),
m4te(60),
dte6(61),
cda6(62),
qmag(63),
voip(64),
tri-rs232a(65),
clka(66),
other(98),
unknown(99),
ctrl(100)
}
AlarmModelType ::= INTEGER {
fe1(0),
ft1(1),
rs232-8(2),
oct-rt-b(3),
v35(4),
x50(5),
dtu-6(6),
dtu-10(7),
mdsl(8),
ls-optical(9),
em(10),
fxs(11),
router(12),
fxo(13),
afr-e1(14),
afr-t1(15),
magneto(16),
ocudp(17),
quad-e1(18),
quad-t1(19),
mdsl-a(21),
v35-a(22),
gshdsl-4(23),
gshdsl-2(24),
g703(25),
mquad-e1(26),
mquad-t1(27),
dry-contact(28),
fom(29),
router-a(30),
controller(32),
pseudoWire(33),
conference(37),
octDte(38),
tri-e1(39),
tri-t1(40),
m4te(41),
sdte(42),
tdmoe(43),
oct-dbra(44),
socudp(45),
rs232a(48),
abra(49),
tta(50),
dte6(51),
cda6(52),
clka(58),
x21-a(91),
v36-a(92),
rs422-a(93),
eia530-rs449-a(94),
unknown(99)
}
GenClockIndex ::= INTEGER {
internal(1),
port-A(2),
port-B(3),
port-C(4),
port-D(5),
external(6),
slot-A-port-1(7),
slot-A-port-2(8),
slot-A-port-3(9),
slot-A-port-4(10),
slot-B-port-1(11),
slot-B-port-2(12),
slot-B-port-3(13),
slot-B-port-4(14),
slot-C-port-1(15),
slot-C-port-2(16),
slot-C-port-3(17),
slot-C-port-4(18),
slot-D-port-1(19),
slot-D-port-2(20),
slot-D-port-3(21),
slot-D-port-4(22),
slot-1-port-1(23),
slot-1-port-2(24),
slot-1-port-3(25),
slot-1-port-4(26),
slot-2-port-1(27),
slot-2-port-2(28),
slot-2-port-3(29),
slot-2-port-4(30),
slot-3-port-1(31),
slot-3-port-2(32),
slot-3-port-3(33),
slot-3-port-4(34),
slot-4-port-1(35),
slot-4-port-2(36),
slot-4-port-3(37),
slot-4-port-4(38),
slot-5-port-1(39),
slot-5-port-2(40),
slot-5-port-3(41),
slot-5-port-4(42),
slot-6-port-1(43),
slot-6-port-2(44),
slot-6-port-3(45),
slot-6-port-4(46),
slot-7-port-1(47),
slot-7-port-2(48),
slot-7-port-3(49),
slot-7-port-4(50),
slot-8-port-1(51),
slot-8-port-2(52),
slot-8-port-3(53),
slot-8-port-4(54),
slot-9-port-1(55),
slot-9-port-2(56),
slot-9-port-3(57),
slot-9-port-4(58),
slot-10-port-1(59),
slot-10-port-2(60),
slot-10-port-3(61),
slot-10-port-4(62),
slot-11-port-1(63),
slot-11-port-2(64),
slot-11-port-3(65),
slot-11-port-4(66),
slot-12-port-1(67),
slot-12-port-2(68),
slot-12-port-3(69),
slot-12-port-4(70)
}
SSMClockIndex ::= INTEGER {
none(1),
port-A(2),
port-B(3),
port-C(4),
port-D(5),
slot-A-port-1(6),
slot-A-port-2(7),
slot-A-port-3(8),
slot-A-port-4(9),
slot-B-port-1(10),
slot-B-port-2(11),
slot-B-port-3(12),
slot-B-port-4(13),
slot-C-port-1(14),
slot-C-port-2(15),
slot-C-port-3(16),
slot-C-port-4(17),
slot-D-port-1(18),
slot-D-port-2(19),
slot-D-port-3(20),
slot-D-port-4(21),
slot-1-port-1(22),
slot-1-port-2(23),
slot-1-port-3(24),
slot-1-port-4(25),
slot-2-port-1(26),
slot-2-port-2(27),
slot-2-port-3(28),
slot-2-port-4(29),
slot-3-port-1(30),
slot-3-port-2(31),
slot-3-port-3(32),
slot-3-port-4(33),
slot-4-port-1(34),
slot-4-port-2(35),
slot-4-port-3(36),
slot-4-port-4(37),
slot-5-port-1(38),
slot-5-port-2(39),
slot-5-port-3(40),
slot-5-port-4(41),
slot-6-port-1(42),
slot-6-port-2(43),
slot-6-port-3(44),
slot-6-port-4(45),
slot-7-port-1(46),
slot-7-port-2(47),
slot-7-port-3(48),
slot-7-port-4(49),
slot-8-port-1(50),
slot-8-port-2(51),
slot-8-port-3(52),
slot-8-port-4(53),
slot-9-port-1(54),
slot-9-port-2(55),
slot-9-port-3(56),
slot-9-port-4(57),
slot-10-port-1(58),
slot-10-port-2(59),
slot-10-port-3(60),
slot-10-port-4(61),
slot-11-port-1(62),
slot-11-port-2(63),
slot-11-port-3(64),
slot-11-port-4(65),
slot-12-port-1(66),
slot-12-port-2(67),
slot-12-port-3(68),
slot-12-port-4(69),
internal(70),
external(71)
}
AlarmSlotIndex ::= INTEGER {
none(0),
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
redundant(98),
external(99),
ctrl1(101),
ctrl2(102),
ctrl1-external(103),
ctrl2-external(104),
power1(111),
power2(112),
fan1(121),
fan2(122),
na(255)
}
MapSlotIndex ::= INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
slot-INBAND(17),
pw(18),
none(254),
idle(255)
}
MapSetSlot ::= INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
slot-INBAND(17),
pw(18),
none(254)
}
SmallSlotIndex ::= INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-E(5),
slot-F(6),
slot-H(7),
slot-J(8),
slot-K(9)
}
LargeSlotIndex ::= INTEGER {
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16)
}
BackupLink ::= INTEGER {
link-A(1),
link-B(2),
link-C(3),
link-D(4),
none(5)
}
NewBackupLink ::= INTEGER {
link-A(1),
link-B(2),
link-C(3),
link-D(4),
link-1(5),
link-2(6),
link-3(7),
link-4(8),
link-5(9),
link-6(10),
link-7(11),
link-8(12),
link-9(13),
link-10(14),
link-11(15),
link-12(16),
none(17)
}
MapPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
port-9(9),
port-10(10),
port-11(11),
port-12(12),
port-13(13),
port-14(14),
port-15(15),
port-16(16),
port-17(17),
port-18(18),
port-19(19),
port-20(20),
port-21(21),
port-22(22),
port-23(23),
port-24(24),
port-25(25),
port-26(26),
port-27(27),
port-28(28),
port-29(29),
port-30(30),
port-31(31),
port-32(32),
port-33(33),
port-34(34),
port-35(35),
port-36(36),
port-37(37),
port-38(38),
port-39(39),
port-40(40),
port-41(41),
port-42(42),
port-43(43),
port-44(44),
port-45(45),
port-46(46),
port-47(47),
port-48(48),
port-49(49),
port-50(50),
port-51(51),
port-52(52),
port-53(53),
port-54(54),
port-55(55),
port-56(56),
port-57(57),
port-58(58),
port-59(59),
port-60(60),
port-61(61),
port-62(62),
port-63(63),
port-64(64),
ep1(101),
ep2(102),
cp1(103),
cp2(104),
gp1(121),
gp2(122),
gp3(123),
gp4(124),
gp5(125),
gp6(126),
gp7(127),
gp8(128),
gp9(129),
gp10(130),
gp11(131),
gp12(132),
gp13(133),
gp14(134),
gp15(135),
gp16(136),
gp17(137),
gp18(138),
gp19(139),
gp20(140),
gp21(141),
gp22(142),
gp23(143),
gp24(144),
gp25(145),
gp26(146),
gp27(147),
gp28(148),
gp29(149),
gp30(150),
gp31(151),
gp32(152),
gp33(153),
gp34(154),
gp35(155),
gp36(156),
gp37(157),
gp38(158),
gp39(159),
gp40(160),
gp41(161),
gp42(162),
none(254),
idle(255)
}
G2PortID ::= INTEGER {
port-1(1),
port-3(2)
}
OnePortID ::= INTEGER {
port1(1)
}
ThreePortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3)
}
FourPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4)
}
SixPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6)
}
EightPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8)
}
TenPortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
port-9(9),
port-10(10)
}
TwelvePortID ::= INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
port-9(9),
port-10(10),
port-11(11),
port-12(12)
}
WanID ::= INTEGER {
xx(0),
wan-1(1),
wan-2(2),
wan-3(3),
wan-4(4),
wan-5(5),
wan-6(6),
wan-7(7),
wan-8(8),
wan-9(9),
wan-10(10),
wan-11(11),
wan-12(12),
wan-13(13),
wan-14(14),
wan-15(15),
wan-16(16),
wan-17(17),
wan-18(18),
wan-19(19),
wan-20(20),
wan-21(21),
wan-22(22),
wan-23(23),
wan-24(24),
wan-25(25),
wan-26(26),
wan-27(27),
wan-28(28),
wan-29(29),
wan-30(30),
wan-31(31),
wan-32(32),
wan-33(33),
wan-34(34),
wan-35(35),
wan-36(36),
wan-37(37),
wan-38(38),
wan-39(39),
wan-40(40),
wan-41(41),
wan-42(42),
wan-43(43),
wan-44(44),
wan-45(45),
wan-46(46),
wan-47(47),
wan-48(48),
wan-49(49),
wan-50(50),
wan-51(51),
wan-52(52),
wan-53(53),
wan-54(54),
wan-55(55),
wan-56(56),
wan-57(57),
wan-58(58),
wan-59(59),
wan-60(60),
wan-61(61),
wan-62(62),
wan-63(63),
wan-64(64)
}
TimeslotID ::= INTEGER {
ts-1(1),
ts-2(2),
ts-3(3),
ts-4(4),
ts-5(5),
ts-6(6),
ts-7(7),
ts-8(8),
ts-9(9),
ts-10(10),
ts-11(11),
ts-12(12),
ts-13(13),
ts-14(14),
ts-15(15),
ts-16(16),
ts-17(17),
ts-18(18),
ts-19(19),
ts-20(20),
ts-21(21),
ts-22(22),
ts-23(23),
ts-24(24),
ts-25(25),
ts-26(26),
ts-27(27),
ts-28(28),
ts-29(29),
ts-30(30),
ts-31(31),
ts-32(32)
}
EthportIndex ::= INTEGER {
eth-1(1),
eth-2(2),
eth-3(3),
eth-4(4)
}
Tributaryport ::= INTEGER{
trib-1(1),
trib-2(2),
trib-3(3),
trib-4(4)
}
Alarmtributaryport ::= INTEGER {
trib-1(1),
trib-2(2),
trib-3(3),
trib-4(4),
none (5)
}
Bundleid ::= INTEGER {
idle(1),
bundle0(2),
bundle1(3),
bundle2(4),
bundle3(5),
bundle4(6),
bundle5(7),
bundle6(8),
bundle7(9),
bundle8(10),
bundle9(11),
bundle10(12),
bundle11(13),
bundle12(14),
bundle13(15),
bundle14(16),
bundle15(17),
bundle16(18),
bundle17(19),
bundle18(20),
bundle19(21),
bundle20(22),
bundle21(23),
bundle22(24),
bundle23(25),
bundle24(26),
bundle25(27),
bundle26(28),
bundle27(29),
bundle28(30),
bundle29(31),
bundle30(32),
bundle31(33)
}
Bundleid2 ::= INTEGER {
bundle0(1),
bundle1(2),
bundle2(3),
bundle3(4),
bundle4(5),
bundle5(6),
bundle6(7),
bundle7(8),
bundle8(9),
bundle9(10),
bundle10(11),
bundle11(12),
bundle12(13),
bundle13(14),
bundle14(15),
bundle15(16),
bundle16(17),
bundle17(18),
bundle18(19),
bundle19(20),
bundle20(21),
bundle21(22),
bundle22(23),
bundle23(24),
bundle24(25),
bundle25(26),
bundle26(27),
bundle27(28),
bundle28(29),
bundle29(30),
bundle30(31),
bundle31(32)
}
AlarmSeverity ::= INTEGER {
disable(1),
major(2),
critical(3),
minor(4)
}
AlarmType ::= INTEGER {
alarm-cut-off(0),
slot-no-work(1),
slot-start(2),
slot-clock-loss(3),
primary-start(4),
redundant-loss(5),
backup-switch(6),
power-fail(7),
redundant-chksum-error(8),
fan-fail(9),
map-switch(10),
link-protection(11),
redundant-insert(12),
redundant-unsync(13),
redundant-to-primary(14),
card-type-mismatch(15),
link-id-mismatch(16),
power-consumption-alarm(17),
ssm-clock-switch(18),
management-alarm(19),
inbandSwitchAlarm(29), --//RIKER2021 SilverCreek
master-clock-loss(103),
second-clock-loss(104),
redundant-ext-clock-loss(105),
qe1t1-1for1-switch(106),
ds0-sncp-switch(111),
dbra-protection-alarm(112),
ring-id-fail-alarm(113),
card-sn-mismatch-alarm(116),
too-many-rtab-card(117),
sntp-alarm(121),
slotInactive(123),
redundantLoss(124),
redundantUnsync(125),
cardTypeMismatch(126),
externalAlarm(131),
pw-arp-alarm(140),
pw-rx-los-alarm(141),
pw-los-of-bundle-alarm(142),
pw-underrun-alarm(143),
pw-overrun-alarm(144),
pw-lbit-alarm(145),
pw-rbit-alarm(146),
pw-synce-clock-alarm(147),
pw-ip-conflict-alarm(148),
ctrl-port-link-alarm(149),
ctrl1-eth1-elec-link-alarm(160),
ctrl1-eth2-elec-link-alarm(161),
ctrl1-eth1-opt-link-alarm(162),
ctrl1-eth2-opt-link-alarm(163),
ctrl-eth1-looping-alarm(164),
ctrl-eth2-looping-alarm(165),
ctrl2-eth1-elec-link-alarm(166),
ctrl2-eth2-elec-link-alarm(167),
ctrl2-eth1-opt-link-alarm(168),
ctrl2-eth2-opt-link-alarm(169),
e1-rai(201),
e1-ais(202),
e1-los(203),
e1-lof(204),
e1-bpv(205),
e1-es (206),
e1-uas(207),
e1-css(208),
ais-ins(209),
e1-tcpa(210),
t1-yel(221),
t1-ais(222),
t1-los(223),
t1-lof(224),
t1-bpv(225),
t1-es (226),
t1-uas(227),
t1-css(228),
t1-ais-ins(229),
t1-tcpa(230),
atm-los(261),
atm-ais(262),
atm-rdi(263),
atm-loc(264),
fr-lkd (265),
gshdsl-htuc-los-loop1(301),
gshdsl-htuc-los-loop2(302),
gshdsl-htur-los-loop1(303),
gshdsl-htur-los-loop2(304),
gshdsl-htuc-e1t1-los-lof(305),
gshdsl-htur-e1t1-los-lof(306),
gshdsl-htuc-es-15m-loop1(307),
gshdsl-htuc-es-15m-loop2(308),
gshdsl-htur-es-15m-loop1(309),
gshdsl-htur-es-15m-loop2(310),
gshdsl-htuc-e1t1-es-15m(311),
gshdsl-htur-e1t1-es-15m(312),
gshdsl-htuc-ses-15m-loop1(313),
gshdsl-htuc-ses-15m-loop2(314),
gshdsl-htur-ses-15m-loop1(315),
gshdsl-htur-ses-15m-loop2(316),
gshdsl-htuc-e1t1-ses-15m(317),
gshdsl-htur-e1t1-ses-15m(318),
gshdsl-htuc-es-24h-loop1(319),
gshdsl-htuc-es-24h-loop2(320),
gshdsl-htur-es-24h-loop1(321),
gshdsl-htur-es-24h-loop2(322),
gshdsl-htuc-e1t1-es-24h(323),
gshdsl-htur-e1t1-es-24h(324),
gshdsl-htuc-ses-24h-loop1(325),
gshdsl-htuc-ses-24h-loop2(326),
gshdsl-htur-ses-24h-loop1(327),
gshdsl-htur-ses-24h-loop2(328),
gshdsl-htuc-e1t1-ses-24h(329),
gshdsl-htur-e1t1-ses-24h(330),
gshdsl-sealing-current(331),
gshdsl-mclk-loss(332),
gshdsl-htuc-dte-rts(333),
gshdsl-htur-dte-rts(334),
gshdsl-htuc-dte-extclk(335),
gshdsl-htur-dte-extclk(336),
gshdsl-dying-gasp-alarm(337),
gshdsl-loop-attenu-alarm(338),
gshdsl-low-noise-margin(339),
gshdsl-htur-link-down(340),
mdsl-master-los(361),
mdsl-slave-los(362),
mdsl-master-es-15m(363),
mdsl-slave-es-15m(364),
mdsl-master-ses-15m(365),
mdsl-slave-ses-15m(366),
mdsl-master-es-24h(367),
mdsl-slave-es-24h(368),
mdsl-master-ses-24h(369),
mdsl-slave-ses-24h(370),
mdsl-mclk-loss(371),
mdsl-sealing-current(372),
lan1-link-down(401),
lan2-link-down(402),
lan3-link-down(403),
lan4-link-down(404),
lan5-link-down(405),
lan6-link-down(406),
lan7-link-down(407),
lan8-link-down(408),
lso-los(441),
lso-yel(442),
lso-es (443),
lso-ses(444),
lso-uas(445),
ocudp-los(461),
ocudp-oos(462),
ocudp-es (465),
ocudp-ses(466),
ocudp-uas(467),
ocudp-loopbk(468),
ocudp-test(469),
ocudp-lof(470),
dte-unsync(501),
x50-unsync(502),
dtu-unsync(503),
dte-ext-clk-loss(511),
dte-rts-loss(512),
dte-remote-alarm(513),
fpga-fail(514),
rts-loss(521),
lolc(522),
loch(523),
cre(524),
term-conn(525),
term-disconn(526),
g703-los(541),
fom-opt-local-lof (601),
fom-opt-local-los (602),
fom-opt-local-rai (603),
fom-opt-remote-lof(604),
fom-opt-remote-los(605),
fom-opt-local-es (606),
fom-opt-local-ses (607),
fom-opt-local-uas (608),
fom-e1-local-lof (617),
fom-e1-remote-lof (618),
fom-e1-local-es (619),
fom-e1-local-ses (620),
fom-e1-local-uas (621),
fom-e1-local-bpv (622),
dc-n1-p1(701),
dc-n1-p2(702),
dc-n1-p3(703),
dc-n1-p4(704),
dc-n2-p1(705),
dc-n2-p2(706),
dc-n2-p3(707),
dc-n2-p4(708),
arbaCardProtection(780),
tdmoe-arp-lost(1001),
tdmoe-rx-lost(1002),
tdmoe-loss-of-bundle(1003),
tdmoe-jit-buf-underrun(1004),
tdmoe-jit-buf-overrun(1005),
tdmoe-eth1-link-down(1006),
tdmoe-eth2-link-down(1007),
tdmoe-eth3-link-down(1008),
tdmoe-eth4-link-down(1009),
tdmoe-sfp1-tx-power-high(1010),
tdmoe-sfp2-tx-power-high(1011),
tdmoe-sfp1-tx-power-low(1012),
tdmoe-sfp2-tx-power-low(1013),
tdmoe-sfp1-rx-power-high(1014),
tdmoe-sfp2-rx-power-high(1015),
tdmoe-sfp1-rx-power-low(1016),
tdmoe-sfp2-rx-power-low(1017),
tdmoe-sfp1-tx-bias-high(1018),
tdmoe-sfp2-tx-bias-high(1019),
tdmoe-sfp1-tx-bias-low(1020),
tdmoe-sfp2-tx-bias-low(1021),
tdmoe-bp-pri-hb-lost(1022),
tdmoe-bp-sec-hb-lost(1023),
tdmoe-bp-bundle-sw-to-pri(1024),
tdmoe-bp-bundle-sw-to-sec(1025),
tdmoe-bundle-l-bit(1026),
tdmoe-bundle-r-bit(1027),
tta-input-trigger(1101),
tta-output-trigger(1102),
tta-round-trip-time-range(1103),
tta-local-channel-lost(1104),
tta-remote-channel-lost(1105),
tta-IRIG-loss(1106),
tta-test-trigger(1107),
tta-test-Response(1108),
cda6-los(1121),
cda6-loo(1122),
cda6-tx-clk-loss(1123),
cda6-rx-clk-loss(1124),
wan1LinkDown(1201),
wan2LinkDown(1202),
wan3LinkDown(1203),
wan4LinkDown(1204),
wan5LinkDown(1205),
wan6LinkDown(1206),
wan7LinkDown(1207),
wan8LinkDown(1208),
wan9LinkDown(1209),
wan10LinkDown(1210),
wan11LinkDown(1211),
wan12LinkDown(1212),
wan13LinkDown(1213),
wan14LinkDown(1214),
wan15LinkDown(1215),
wan16LinkDown(1216),
wan17LinkDown(1217),
wan18LinkDown(1218),
wan19LinkDown(1219),
wan20LinkDown(1220),
wan21LinkDown(1221),
wan22LinkDown(1222),
wan23LinkDown(1223),
wan24LinkDown(1224),
wan25LinkDown(1225),
wan26LinkDown(1226),
wan27LinkDown(1227),
wan28LinkDown(1228),
wan29LinkDown(1229),
wan30LinkDown(1230),
wan31LinkDown(1231),
wan32LinkDown(1232),
wan33LinkDown(1233),
wan34LinkDown(1234),
wan35LinkDown(1235),
wan36LinkDown(1236),
wan37LinkDown(1237),
wan38LinkDown(1238),
wan39LinkDown(1239),
wan40LinkDown(1240),
wan41LinkDown(1241),
wan42LinkDown(1242),
wan43LinkDown(1243),
wan44LinkDown(1244),
wan45LinkDown(1245),
wan46LinkDown(1246),
wan47LinkDown(1247),
wan48LinkDown(1248),
wan49LinkDown(1249),
wan50LinkDown(1250),
wan51LinkDown(1251),
wan52LinkDown(1252),
wan53LinkDown(1253),
wan54LinkDown(1254),
wan55LinkDown(1255),
wan56LinkDown(1256),
wan57LinkDown(1257),
wan58LinkDown(1258),
wan59LinkDown(1259),
wan60LinkDown(1260),
wan61LinkDown(1261),
wan62LinkDown(1262),
wan63LinkDown(1263),
wan64LinkDown(1264),
na(9999)
}
GroupChannelID ::= INTEGER {
ch1master(1),
ch2master(2),
ch3slave(3),
ch4slave(4),
ch5slave(5),
ch6slave(6),
ch7slave(7),
ch8slave(8),
ch9slave(9),
ch10slave(10),
ch11slave(11),
ch12slave(12),
ch13slave(13),
ch14slave(14),
ch15slave(15),
ch16slave(16)
}
SignalingBit ::= INTEGER {
s0000(0),
s0001(1),
s0010(2),
s0011(3),
s0100(4),
s0101(5),
s0110(6),
s0111(7),
s1000(8),
s1001(9),
s1010(10),
s1011(11),
s1100(12),
s1101(13),
s1110(14),
s1111(15)
}
EMOffOn ::= INTEGER {
off(1),
on(2),
null(3)
}
SubSlot ::= INTEGER {
none(1)
}
SubCardType ::= INTEGER {
none(1)
}
SubChannel ::= INTEGER {
none(1)
}
AlmVC ::= INTEGER {
none(1)
}
AlmLocation ::= INTEGER {
local(1)
}
AlmGPInt1 ::= INTEGER {
none(1)
}
AlmPairing ::= INTEGER {
singleshot(1),
paired(2)
}
Anyds1Slot ::= INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
pw(18),
none(254)
}
--======================================================================--
--======================================================================--
loopTelecom OBJECT IDENTIFIER ::= { enterprises 823 }
loop-AM3440-CCPB-A OBJECT IDENTIFIER ::= { loopTelecom 34441 }
controller OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 1 }
e1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 2 }
t1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 3 }
dtu-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 4 }
dte-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 5 }
x50-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 6 }
dtu6-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 7 }
mdsl-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 11 }
em-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 12 }
fxs-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 13 }
rtr-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 14 }
afr-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 15 }
fxo-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 16 }
mag-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 17 }
qe1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 21 }
qt1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 22 }
g703-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 23 }
mqe1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 24 }
mqt1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 25 }
gdsl2-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 26 }
gdsl4-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 27 }
dc-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 28 }
fom-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 29 }
router-a-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 30 }
ls-optical-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 31 }
ocudp-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 32 }
oct-rt-b-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 33 }
ts-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 34 }
qfxo-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 35 }
qfxs-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 36 }
qem-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 37 }
conference-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 38 }
tri-e1-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 39 }
triT1card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 40 }
sdte-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 50 }
tdmoe-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 51 }
oct-dbra-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 52 }
socudp-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 53 }
octDte-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 54 }
eca-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 56 }
rs232a-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 57 }
abra-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 58 }
tta-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 59 }
m4teCard OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 60 }
dte6-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 61 }
cda6-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 62 }
qmag-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 63 }
voip-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 64 }
trirs232a-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 65 }
clka-card OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 66 }
--======================================================================--
--======================================================================--
--======================================================================--
-- Controller MIB
--======================================================================--
-- clockSourceTable OBJECT IDENTIFIER ::= { controller 1 }
-- alarmControlTable OBJECT IDENTIFIER ::= { controller 2 }
-- commandControlTable OBJECT IDENTIFIER ::= { controller 3 }
-- systemInformationTable OBJECT IDENTIFIER ::= { controller 4 }
-- alarmQueueSummaryTable OBJECT IDENTIFIER ::= { controller 5 }
-- ledStatus OBJECT IDENTIFIER ::= { controller 6 }
-- controllerLedTable OBJECT IDENTIFIER ::= { ledStatus 1 }
-- sCardLedTable OBJECT IDENTIFIER ::= { ledStatus 2 }
-- slotLedTable OBJECT IDENTIFIER ::= { ledStatus 3 }
-- dualControllerTable OBJECT IDENTIFIER ::= { controller 7 }
-- channelMap OBJECT IDENTIFIER ::= { controller 8 }
-- tsiMapNumber OBJECT IDENTIFIER ::= { channelMap 1 }
-- currentMapTable OBJECT IDENTIFIER ::= { channelMap 2 }
-- channelMapTable OBJECT IDENTIFIER ::= { channelMap 3 }
-- setMapTable OBJECT IDENTIFIER ::= { channelMap 4 }
-- slotModelTable OBJECT IDENTIFIER ::= { controller 9 }
-- dualPowerTable OBJECT IDENTIFIER ::= { controller 10 }
-- linkbackup OBJECT IDENTIFIER ::= { controller 11 }
-- fileTransferTable OBJECT IDENTIFIER ::= { controller 12 }
-- ctlBertTable OBJECT IDENTIFIER ::= { controller 14 }
-- ssmClockSourceTable OBJECT IDENTIFIER ::= { controller 15 }
-- portStateControl OBJECT IDENTIFIER ::= { controller 16 }
-- pdhRingProtection OBJECT IDENTIFIER ::= { controller 17 }
-- qe1PairProtection OBJECT IDENTIFIER ::= { controller 18 }
-- ds0sncpProtection OBJECT IDENTIFIER ::= { controller 19 }
-- CurrentActiveAlarmSummaryTable OBJECT IDENTIFIER ::= { controller 21 }
-- sntpInfoTable OBJECT IDENTIFIER ::= { controller 22 }
-- sysNetworkManagement OBJECT IDENTIFIER ::= { controller 23 }
-- remDevUpgradeTable OBJECT IDENTIFIER ::= { controller 24 }
-- syslogSetupTable OBJECT IDENTIFIER ::= { controller 25 }
-- inbandProtectionTable OBJECT IDENTIFIER ::= { controller 26 }
-- radiusSetupTable OBJECT IDENTIFIER ::= { controller 27 }
-- featureActivation OBJECT IDENTIFIER ::= { controller 28 }
-- ssmConversionTable OBJECT IDENTIFIER ::= { controller 29 } NFS-15000325 add by Bryan
-- externalAlarmTable OBJECT IDENTIFIER ::= { controller 30 }
-- ccbTimingSource OBJECT IDENTIFIER ::= { controller 31 }
-- consoleTelnetUser OBJECT IDENTIFIER ::= { controller 32 }
-- ethernetTable OBJECT IDENTIFIER ::= { controller 33 }
-- pwCtrlSetupTable OBJECT IDENTIFIER ::= { controller 34 }
-- pwCtrlStatusTable OBJECT IDENTIFIER ::= { controller 35 }
-- anyds1Protection OBJECT IDENTIFIER ::= { controller 36 }
-- uplinkInbandTable OBJECT IDENTIFIER ::= { controller 37 }
-- advancedStatusTable OBJECT IDENTIFIER ::= { controller 38 }
--======================================================================--
--
-- Clock Source Table
--
clockSourceTable OBJECT IDENTIFIER ::= { controller 1 }
ccClockIndicator OBJECT-TYPE
SYNTAX INTEGER {
master(1),
second(2),
internal(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock indicator"
::= { clockSourceTable 1 }
ccMasterClock OBJECT-TYPE
SYNTAX GenClockIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Master clock setting"
::= { clockSourceTable 2 }
ccSecondClock OBJECT-TYPE
SYNTAX GenClockIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Second clock setting"
::= { clockSourceTable 3 }
ccClkRecoverMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
automatic(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clk Recover Mode"
::= { clockSourceTable 4 }
ccClockStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
loss(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clock status indicate current clock status."
::= { clockSourceTable 5 }
ccExternalClockType OBJECT-TYPE
SYNTAX INTEGER {
t1(1),
e1(2),
e1-120ohm(3),
e1-75ohm(4),
ext-2048Khz-75ohm(5),
ext-2048Khz-120ohm(6),
na(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock Type."
::= { clockSourceTable 6 }
ccDualExtClkProtect OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Dual External Clock Protection"
::= { clockSourceTable 7 }
ccRedExtClkStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
loss(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant External Clock Status"
::= { clockSourceTable 8 }
ccClockHoldOver OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
not-support(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hold-over"
::= { clockSourceTable 11 }
ccHoldOverState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
hold-over(2),
not-support(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clock hold-over state"
::= { clockSourceTable 12 }
ccFramePulsePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frame Pulse Period: Hz"
::= { clockSourceTable 13 }
--
-- Alarm Control Table
--
alarmControlTable OBJECT IDENTIFIER ::= { controller 2 }
ccAlarmActive OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controller Alarm Setup"
::= { alarmControlTable 1 }
ccRelayActive OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
manual(2),
auto(3),
period(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controller Relay Setup:
manual - user press ACO or VT100 command to clear alarm;
auto - auto clear alarm when alarm remove occur;
period - auto clear after few second."
::= { alarmControlTable 2 }
ccAlarmCutOff OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Cut Off Setup"
::= { alarmControlTable 3 }
ccPortInactive OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for slot no work,
redundant loss, redundant checksum error,
and redundant unsync alarm"
::= { alarmControlTable 4 }
ccPortStartUp OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for slot start, primary start,
redundant insert, and redundant to primary alarm"
::= { alarmControlTable 5 }
ccClockLossAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for clock loss alarm"
::= { alarmControlTable 6 }
ccLinkSwitch OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for link back switch alarm"
::= { alarmControlTable 7 }
ccMapSwitch OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for map switch alarm"
::= { alarmControlTable 8 }
ccPowerAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for power fail and fan fail alarm"
::= { alarmControlTable 9 }
ccTypeMismatch OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for card type mismatch and link id mismatch alarm"
::= { alarmControlTable 10 }
ccDualCPUalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for dual-CPU alarm"
::= { alarmControlTable 11 }
ccManagementAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm setup for management alarm"
::= { alarmControlTable 12 }
ccRelayPeriod OBJECT-TYPE
SYNTAX INTEGER (1..86400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm relay period."
::= { alarmControlTable 13 }
ccSNMPLinkDownAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP port link down alarm"
::= { alarmControlTable 14 }
--
-- Command Control Table
--
commandControlTable OBJECT IDENTIFIER ::= { controller 3 }
ccStoreConfiguration OBJECT-TYPE
SYNTAX INTEGER {
store(1),
retrieve(2),
no(3),
in-storing(11),
in-retrieving(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Command:Store/Retrieve Controller Configuration"
::= { commandControlTable 1 }
ccAlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Reset Alarm Queue"
::= { commandControlTable 2 }
ccClearACO OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Clear ACO"
::= { commandControlTable 3 }
ccReturnToDefault OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Return to default"
::= { commandControlTable 4 }
ccSystemReset OBJECT-TYPE
SYNTAX INTEGER {
cold-restart-primary(1),
redundant-controller(2),
no(3),
warm-restart-primary(4),
reset-system(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Controller Reset"
::= { commandControlTable 5 }
ccClockMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
ssm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Change System Clock Mode"
::= { commandControlTable 6 }
ccIdleSignalling OBJECT-TYPE
SYNTAX INTEGER {
b0001(1),
b0010(2),
b0011(3),
b0100(4),
b0101(5),
b0110(6),
b0111(7),
b1000(8),
b1001(9),
b1010(10),
b1011(11),
b1100(12),
b1101(13),
b1110(14),
b1111(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command:Change Idle Signalling Code"
::= { commandControlTable 7 }
ccInitNewCard OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initial New Card"
::= { commandControlTable 8 }
ccUnregisterCard OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Un-register a card after un-plugged"
::= { commandControlTable 9 }
ccPasswordChecking OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..28))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Change stetting of password checking for console/telnet"
::= { commandControlTable 21 }
ccConsoleLockout OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..28))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Console lockout or unlock"
::= { commandControlTable 22 }
ccForceAllLEDFlashing OBJECT-TYPE
SYNTAX INTEGER {
allFlashing(1),
allNormal(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force all LED flashing on controller"
::= { commandControlTable 23 }
ccForceAllLEDTime OBJECT-TYPE
SYNTAX INTEGER (0..86400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Timer (seconds) to force all LED flashing on controller
0=forever"
::= { commandControlTable 24 }
ccTelnetLockout OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..28))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Telnet lockout or unlock"
::= { commandControlTable 25 }
--
-- SYSTEM Information Table
--
systemInformationTable OBJECT IDENTIFIER ::= { controller 4 }
ccSerialNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial Number "
::= { systemInformationTable 1 }
ccMainboardVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mainboard Version"
::= { systemInformationTable 2 }
ccPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version"
::= { systemInformationTable 3 }
ccSystemDateTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Date and Time"
::= { systemInformationTable 4 }
ccRedSerialNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant board Serial Number "
::= { systemInformationTable 11 }
ccRedBoardVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant board hardware Version"
::= { systemInformationTable 12 }
ccRedFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant board firmware Version"
::= { systemInformationTable 13 }
ccConsoleStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
-- password-check-enable(2),
console-lockout(3),
console-login(4),
telnet1-login(10),
telnet2-login(11),
telnet3-login(12),
telnet4-login(13),
telnet5-login(14),
ssh1-login(15),
ssh2-login(16),
ssh3-login(17),
ssh4-login(18),
ssh5-login(19)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Console/Telnet status"
::= { systemInformationTable 21 }
ccSupportSmallVoiceCard OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Support small voice card in this chassis?"
::= { systemInformationTable 31 }
ccControllerType OBJECT-TYPE
SYNTAX INTEGER {
cca(1),
ccb(2),
ccpa(3),
ccpswa(4),
ccpb(5),
ccpbdcs(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CCA, CCB, or CCPA"
::= { systemInformationTable 32 }
-- ccChassisType OBJECT-TYPE
-- SYNTAX INTEGER {
-- general(1),
-- chxL(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "chassis type"
-- ::= { systemInformationTable 33 }
ccConsoleLockoutState OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
unlocked(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Console lockout state"
::= { systemInformationTable 34 }
ccTelnetLockoutState OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
unlocked(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Telnet lockout state"
::= { systemInformationTable 35 }
--
-- Alarm Queue Summary Table
--
alarmQueueSummaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmQueueSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Alarm Queue."
::= { controller 5 }
alarmQueueSummaryEntry OBJECT-TYPE
SYNTAX AlarmQueueSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"alarm queue entry"
INDEX { ccAlarmQueueIndex }
::= { alarmQueueSummaryTable 1 }
AlarmQueueSummaryEntry ::= SEQUENCE {
ccAlarmQueueIndex INTEGER,
ccAlarmQueueString DisplayString,
ccAlarmType AlarmType,
ccAlarmModel AlarmModelType,
ccAlarmSlot AlarmSlotIndex,
ccAlarmPort AlarmPort,
ccAlarmSeverity AlarmSeverityDisp,
ccAlarmLink AlarmLink,
ccAlarmTimeStamp DisplayString,
ccAlarmSubrack INTEGER,
ccAlarmSubSlot SubSlot,
ccAlarmSubCardType SubCardType,
ccAlarmSubChannel SubChannel,
ccAlarmVC AlmVC,
ccAlarmLocation AlmLocation,
ccAlarmPairing AlmPairing,
ccAlarmGPInt1 AlmGPInt1,
ccAlarmGPStr1 DisplayString
}
ccAlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..10000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { alarmQueueSummaryEntry 1 }
ccAlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { alarmQueueSummaryEntry 2 }
ccAlarmType OBJECT-TYPE
SYNTAX AlarmType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type"
::= { alarmQueueSummaryEntry 3 }
ccAlarmModel OBJECT-TYPE
SYNTAX AlarmModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Model"
::= { alarmQueueSummaryEntry 4 }
ccAlarmSlot OBJECT-TYPE
SYNTAX AlarmSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Slot"
::= { alarmQueueSummaryEntry 5 }
ccAlarmPort OBJECT-TYPE
SYNTAX AlarmPort
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Port"
::= { alarmQueueSummaryEntry 6 }
ccAlarmSeverity OBJECT-TYPE
SYNTAX AlarmSeverityDisp
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Severity"
::= { alarmQueueSummaryEntry 7 }
ccAlarmLink OBJECT-TYPE
SYNTAX AlarmLink
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Link"
::= { alarmQueueSummaryEntry 8 }
ccAlarmTimeStamp OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Time Stamp"
::= { alarmQueueSummaryEntry 9 }
ccAlarmSubrack OBJECT-TYPE
SYNTAX INTEGER {
shelf1(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Subrack"
::= { alarmQueueSummaryEntry 10 }
ccAlarmSubSlot OBJECT-TYPE
SYNTAX SubSlot
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Sub Slot"
::= { alarmQueueSummaryEntry 11 }
ccAlarmSubCardType OBJECT-TYPE
SYNTAX SubCardType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Sub Card Type"
::= { alarmQueueSummaryEntry 12 }
ccAlarmSubChannel OBJECT-TYPE
SYNTAX SubChannel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Sub-Channel Number"
::= { alarmQueueSummaryEntry 13 }
ccAlarmVC OBJECT-TYPE
SYNTAX AlmVC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Virtual Channel Number"
::= { alarmQueueSummaryEntry 14 }
ccAlarmLocation OBJECT-TYPE
SYNTAX AlmLocation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Location"
::= { alarmQueueSummaryEntry 15 }
ccAlarmPairing OBJECT-TYPE
SYNTAX AlmPairing
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"To specify it is Single-shot or Paired alarm type"
::= { alarmQueueSummaryEntry 16 }
ccAlarmGPInt1 OBJECT-TYPE
SYNTAX AlmGPInt1
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"General-Purpose Integer field #1"
::= { alarmQueueSummaryEntry 17 }
ccAlarmGPStr1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm General Purpose field #1 for String type"
::= { alarmQueueSummaryEntry 18 }
--
-- LED Status Table
--
ledStatus OBJECT IDENTIFIER ::= { controller 6 }
--
-- Controller LED Status Table
--
controllerLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF ControllerLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Controller LED status table."
::= { ledStatus 1 }
controllerLedEntry OBJECT-TYPE
SYNTAX ControllerLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Controller LED status entry"
INDEX { ccLedIndex }
::= { controllerLedTable 1 }
ControllerLedEntry ::= SEQUENCE {
ccLedIndex INTEGER,
ccLedName DisplayString,
ccLedColor INTEGER
}
ccLedIndex OBJECT-TYPE
SYNTAX INTEGER (1..6)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controller Led Number Index"
::= { controllerLedEntry 1 }
ccLedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controller Led Name"
::= { controllerLedEntry 2 }
ccLedColor OBJECT-TYPE
SYNTAX INTEGER {
none(0),
off(1),
red(2),
green(3),
yellow(4),
redFlash(5),
greenFlash(6),
yellowFlash(7),
greenFlashRed(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Controller Led Color"
::= { controllerLedEntry 3 }
--
-- Small Card LED Status Table
--
sCardLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF SCardLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Small Card LED status table."
::= { ledStatus 2 }
sCardLedEntry OBJECT-TYPE
SYNTAX SCardLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Small Card LED status entry"
INDEX { sCardLedIndex }
::= { sCardLedTable 1 }
SCardLedEntry ::= SEQUENCE {
sCardLedIndex INTEGER,
sCardLedName DisplayString,
sCardLedColor INTEGER
}
sCardLedIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Small Card Led Number Index"
::= { sCardLedEntry 1 }
sCardLedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Small Card Led Name"
::= { sCardLedEntry 2 }
sCardLedColor OBJECT-TYPE
SYNTAX INTEGER {
none(0),
off(1),
red(2),
green(3),
yellow(4),
redFlash(5),
greenFlash(6),
yellowFlash(7),
greenFlashRed(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Small Card Led Color"
::= { sCardLedEntry 3 }
--
-- Slot LED Status Table
--
slotLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlotLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot LED status table."
::= { ledStatus 3 }
slotLedEntry OBJECT-TYPE
SYNTAX SlotLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot LED status entry"
INDEX { slotLedIndex ,
portLedIndex }
::= { slotLedTable 1 }
SlotLedEntry ::= SEQUENCE {
slotLedIndex GenSlotID,
portLedIndex INTEGER,
portLedColor INTEGER,
portLedName INTEGER
}
slotLedIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot Led Number Index"
::= { slotLedEntry 1 }
portLedIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Led Number Index"
::= { slotLedEntry 2 }
portLedColor OBJECT-TYPE
SYNTAX INTEGER {
none(0),
off(1),
red(2),
green(3),
yellow(4),
redFlash(5),
greenFlash(6),
yellowFlash(7),
greenFlashRed(8),
green-and-yellow(9),
greenFlash-1-hz(10),
greenFlash-4-hz(11),
greenFlash-8-hz(12),
greenFlash-32-hz(13),
redFlash-1-hz(14),
redFlash-4-hz(15),
redFlash-8-hz(16),
redFlash-32-hz(17)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Led Color"
::= { slotLedEntry 3 }
portLedName OBJECT-TYPE
SYNTAX INTEGER {
port(0),
a-law(1),
u-law(2),
freq-12K-hz(3),
freq-16K-hz(4),
imp-600-ohm(5),
imp-900-ohm(6),
side-a(7),
side-b(8),
with-2-WIRE(9),
with-4-WIRE(10),
ring-across-l1-l2(11),
ring-across-l1-gnd(12),
type-1(13),
type-2(14),
type-3(15),
type-4(16),
type-5(17),
setByDip(18),
active(19),
type(20),
los(21),
sync(22),
--12MAG
ring-active(23),
test-active(24),
--VoIP
alm(25),
voip(26),
test(27),
wan(28),
lan1(29),
lan2(30),
--8UDTE
omnibus(31),
ts(32),
oversampling(33),
throughclock(34),
--ECA
act(40),
s64ms(41),
s128ms(42),
--TTA
alarm(50),
outputPort1(51),
outputPort2(52),
outputPort3(53),
outputPort4(54),
inputPort1(55),
inputPort2(56),
inputPort3(57),
inputPort4(58),
--CDA
controlling(60),
subordinate(61),
port1(101),
port2(102),
port3(103),
port4(104),
port5(105),
port6(106),
port7(107),
port8(108),
act1(121),
act2(122),
act3(123),
act4(124),
act5(125),
act6(126),
act7(127),
act8(128)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Led Name"
::= { slotLedEntry 4 }
--
-- Remote LED Status Table
--
remoteLedTable OBJECT-TYPE
SYNTAX SEQUENCE OF RemoteLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote LED status table."
::= { ledStatus 4 }
remoteLedEntry OBJECT-TYPE
SYNTAX RemoteLedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot LED status entry"
INDEX { remoteSlotLedIndex ,
remotePortLedIndex ,
remoteNumLedIndex }
::= { remoteLedTable 1 }
RemoteLedEntry ::= SEQUENCE {
remoteSlotLedIndex GenSlotID,
remotePortLedIndex INTEGER,
remoteNumLedIndex INTEGER,
remotePortLedColor INTEGER,
remotePortLedName DisplayString
}
remoteSlotLedIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Slot Led Number Index"
::= { remoteLedEntry 1 }
remotePortLedIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Led Number Index"
::= { remoteLedEntry 2 }
remoteNumLedIndex OBJECT-TYPE
SYNTAX INTEGER {
led-1(1),
led-2(2),
led-3(3),
led-4(4),
led-5(5),
led-6(6),
led-7(7),
led-8(8),
led-9(9),
led-10(10),
led-11(11),
led-12(12),
led-13(13),
led-14(14),
led-15(15),
led-16(16),
led-17(17),
led-18(18),
led-19(19),
led-20(20)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Led Number Index"
::= { remoteLedEntry 3 }
remotePortLedColor OBJECT-TYPE
SYNTAX INTEGER {
xx(0),
off(1),
red(2),
green(3),
yellow(4),
redFlash(5),
greenFlash(6),
yellowFlash(7),
greenFlashRed(8),
green-and-yellow(9),
greenFlash-1-hz(10),
greenFlash-4-hz(11),
greenFlash-8-hz(12),
greenFlash-32-hz(13),
redFlash-1-hz(14),
redFlash-4-hz(15),
redFlash-8-hz(16),
redFlash-32-hz(17)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Led Color"
::= { remoteLedEntry 4 }
remotePortLedName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Led Name"
::= { remoteLedEntry 5 }
--
-- Dual Controller Table
--
dualControllerTable OBJECT IDENTIFIER ::= { controller 7 }
ccRedundantHWexist OBJECT-TYPE
SYNTAX INTEGER {
notExist(1),
exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant Controller Hardware Existence"
::= { dualControllerTable 1 }
ccRedundantSWconnect OBJECT-TYPE
SYNTAX INTEGER {
notExist(1),
exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant Controller Software Connection"
::= { dualControllerTable 2 }
ccRedundantSync OBJECT-TYPE
SYNTAX INTEGER {
notSync(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundant Controller Synchronized with Primary"
::= { dualControllerTable 3 }
ccSlotPrimary OBJECT-TYPE
SYNTAX INTEGER {
right-slot(1),
left-slot(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the Slot which Primary Controller Occupied"
::= { dualControllerTable 4 }
--
-- Channel Map Group
--
channelMap OBJECT IDENTIFIER ::= { controller 8 }
--
-- Select TSI map
--
tsiMapNumber OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Index for the TSI Map Used."
::= { channelMap 1 }
--
-- Current Map
--
currentMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Current TSI Map."
::= { channelMap 2 }
currentMapEntry OBJECT-TYPE
SYNTAX CurrentMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An Entry for Current TSI Map."
INDEX { currentChannelMapIndex ,
currentPortIndex ,
currentTimeSlotIndex }
::= { currentMapTable 1 }
CurrentMapEntry ::= SEQUENCE {
currentChannelMapIndex MapSlotIndex,
currentPortIndex GenPortID,
currentTimeSlotIndex INTEGER,
currentChannelType INTEGER,
currentMapToSlot MapSlotIndex,
currentMapToPort MapPortID,
currentMapToTS INTEGER,
currentMapCircuitInfo DisplayString
}
currentChannelMapIndex OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { currentMapEntry 1 }
currentPortIndex OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select port 1~10,
total 10 ports."
::= { currentMapEntry 2 }
currentTimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { currentMapEntry 3 }
currentChannelType OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
signal(3),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot type."
::= { currentMapEntry 4 }
currentMapToSlot OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port number."
::= { currentMapEntry 5 }
currentMapToPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port number."
::= { currentMapEntry 6 }
currentMapToTS OBJECT-TYPE
SYNTAX INTEGER {
ts00(0),
ts01(1),
ts02(2),
ts03(3),
ts04(4),
ts05(5),
ts06(6),
ts07(7),
ts08(8),
ts09(9),
ts10(10),
ts11(11),
ts12(12),
ts13(13),
ts14(14),
ts15(15),
ts16(16),
ts17(17),
ts18(18),
ts19(19),
ts20(20),
ts21(21),
ts22(22),
ts23(23),
ts24(24),
ts25(25),
ts26(26),
ts27(27),
ts28(28),
ts29(29),
ts30(30),
ts31(31),
ts32(32),
idle(33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port time slot."
::= { currentMapEntry 7 }
currentMapCircuitInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Circuit Info"
::= { currentMapEntry 8 }
--
-- Channel Map
--
channelMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Mapping for TSI."
::= { channelMap 3 }
channelMapEntry OBJECT-TYPE
SYNTAX ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Mapping for TSI."
INDEX { ccTsiMapIndex ,
ccChannelMapIndex ,
ccPortIndex ,
ccTimeSlotIndex }
::= { channelMapTable 1 }
ChannelMapEntry ::= SEQUENCE {
ccTsiMapIndex INTEGER,
ccChannelMapIndex MapSlotIndex,
ccPortIndex MapPortID,
ccTimeSlotIndex INTEGER,
ccChannelType INTEGER,
ccMapToSlot MapSlotIndex,
ccMapToPort MapPortID,
ccMapToTS INTEGER,
ccCircuitInfo DisplayString
}
ccTsiMapIndex OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TSI Map index."
::= { channelMapEntry 1 }
ccChannelMapIndex OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { channelMapEntry 2 }
ccPortIndex OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select port 1~10,
total 10 ports."
::= { channelMapEntry 3 }
ccTimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { channelMapEntry 4 }
ccChannelType OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
signal(3),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot type."
::= { channelMapEntry 5 }
ccMapToSlot OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port number."
::= { channelMapEntry 6 }
ccMapToPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port number."
::= { channelMapEntry 7 }
ccMapToTS OBJECT-TYPE
SYNTAX INTEGER {
ts00(0),
ts01(1),
ts02(2),
ts03(3),
ts04(4),
ts05(5),
ts06(6),
ts07(7),
ts08(8),
ts09(9),
ts10(10),
ts11(11),
ts12(12),
ts13(13),
ts14(14),
ts15(15),
ts16(16),
ts17(17),
ts18(18),
ts19(19),
ts20(20),
ts21(21),
ts22(22),
ts23(23),
ts24(24),
ts25(25),
ts26(26),
ts27(27),
ts28(28),
ts29(29),
ts30(30),
ts31(31),
ts32(32),
none(254),
idle(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map to other port time slot."
::= { channelMapEntry 8 }
ccCircuitInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Circuit Info"
::= { channelMapEntry 9 }
--
-- Set Channel Map
--
setMapTable OBJECT IDENTIFIER ::= { channelMap 4 }
setTsiMap OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"select TSI Map index."
::= { setMapTable 1 }
setTargetSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { setMapTable 2 }
setTargetPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Target Port."
::= { setMapTable 3 }
setTargetStartTimeSlot OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Target start time slot index."
::= { setMapTable 4 }
setChannelNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select map channel number."
::= { setMapTable 5 }
setChannelType OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select time slot type."
::= { setMapTable 6 }
setSourceSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map to Source slot number."
::= { setMapTable 7 }
setSourcePort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map to Source port number."
::= { setMapTable 8 }
setSourceStartTimeSlot OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map to Source port time slot."
::= { setMapTable 9 }
setCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
clearTarget(1),
clearAllAndSet(2),
setOnly(3),
forceSet(4),
clearStatus(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set command:
1: clear Target port, start from time slot x;
2: clear (all mapped channel) before set;
3: set olny, if channel not cleared, response error.
4: force clear target and source, then set."
::= { setMapTable 10 }
setMapResult OBJECT-TYPE
SYNTAX INTEGER {
na(1),
ok(2),
err-08(8),
err-09(9),
err-10(10),
err-11(11),
err-12(12),
err-13(13),
err-14(14),
err-15(15),
err-16(16),
err-17(17),
err-18(18),
err-19(19),
err-20(20),
err-21(21),
err-22(22),
err-23(23),
err-24(24),
err-25(25),
err-26(26),
err-27(27),
err-28(28),
err-29(29),
err-30(30),
err-31(31),
err-32(32),
err-33(33),
err-34(34),
err-35(35),
err-36(36),
err-37(37)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set result:
8 Somebody is in programming!
9 No channel is assigned to DTE port!
10 Incorrect total selected channels!
11 Time slot is not IDLE!
12 Time slot (TARGET slot/port) is out of range!
13 Time slot (SOURCE slot/port) is out of range!
14 TARGET slot/port is in CAS mode, Time slot 16 is for signaling!
15 SOURCE slot/port is in CAS mode, Time slot 16 is for signaling!
16 Time slot (TARGET slot/port) conflict!
17 Time slot (TARGET slot/port) is out of range!
18 Time slot (SOURCE. slot/port) is out of range!
19 Port N must be equal Time slot N(TARGET slot)!
20 Port N must be equal Time slot N(SOURCE slot)!
21 Only 1 time slot can be mapped to IN-BAND!
22 DTE only can map to 1 port!
23 Slot D Port 4 TS1 reserved for In-Band Channel!
24 SOURCE slot/port is unframed mode, TARGET slot/port must have full time slot!
25 TARGET slot/port is unframed mode, SOURCE slot/port must have full time slot!
26 TARGET TS should be same as TARGET port number!
27 SOURCE TS should be same as SOURCE port number!
28 TARGET port not exist!
29 SOURCE port not exist!
30 Slot 12 Port 4 TS1 reserved for In-Band Channel!
31 Slot 12 Port 4 can not map 32 TS!
32 Map can not set on 1+1 protection slave side!
33 SOURCE slot/port is unframed mode, can not map to ECA card.
34 TARGET slot/port is unframed mode, can not map to ECA card.
35 SOURCE slot/port is unframed mode, can not map to ABRA card.
36 TARGET slot/port is unframed mode, can not map to ABRA card.
37 ABRA card protection, secondary card can not setup map.
.. "
::= { setMapTable 11 }
setXCtype OBJECT-TYPE
SYNTAX INTEGER {
byTSIfunction(1),
bidirection(2),
multicast(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set TSI function as 1:1 bidirection or 1:N multicast."
::= { setMapTable 12 }
autoActivate OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Auto activate if using MAP match current map #."
::= { setMapTable 13 }
setCircuitInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Circuit Info"
::= { setMapTable 14 }
--
-- clear TSI map
--
clearMapTable OBJECT IDENTIFIER ::= { channelMap 5 }
clearMapNumber OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear for the TSI Map."
::= { clearMapTable 5 }
--
-- Copy TSI map
--
copyMapTable OBJECT IDENTIFIER ::= { channelMap 6 }
fromMapNumber OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Copy TSI Map from the Map"
::= { copyMapTable 1 }
toMapNumber OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Copy TSI Map to the Map"
::= { copyMapTable 2 }
--
-- TSI function
--
setTSIfunction OBJECT-TYPE
SYNTAX INTEGER {
bidirection(1),
multicast(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set TSI function as 1:1 bidirection or 1:N multicast."
::= { channelMap 7 }
--
-- TSI map auto-switch
--
switchMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwitchMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auto TSI map switching."
::= { channelMap 8 }
switchMapEntry OBJECT-TYPE
SYNTAX SwitchMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auto TSI map switching."
INDEX { ccSwMapIndex }
::= { switchMapTable 1 }
SwitchMapEntry ::= SEQUENCE {
ccSwMapIndex INTEGER,
ccSwMapEnable INTEGER,
ccSwMapHour INTEGER,
ccSwMapMinute INTEGER
}
ccSwMapIndex OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TSI Map index."
::= { switchMapEntry 1 }
ccSwMapEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"disable or enable this map switching"
::= { switchMapEntry 2 }
ccSwMapHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"hour for map switching"
::= { switchMapEntry 3 }
ccSwMapMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"minute for map switching"
::= { switchMapEntry 4 }
--
-- Batch command for TSI map
--
batchCommand OBJECT IDENTIFIER ::= { channelMap 9 }
batchSet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"batch set command"
::= { batchCommand 1 }
batchResponse OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"batch response"
::= { batchCommand 2 }
-- map display mode
mapDisplayMode OBJECT-TYPE
SYNTAX INTEGER {
from0(1),
from1(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For INMS only"
::= { channelMap 11 }
--
-- current map hex table
--
currentMapHexTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentMapHexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Current TSI Map by Hex."
::= { channelMap 12 }
currentMapHexEntry OBJECT-TYPE
SYNTAX CurrentMapHexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An Entry for Current TSI Map."
INDEX { currentMapHexSlot , currentMapHexPort }
::= { currentMapHexTable 1 }
CurrentMapHexEntry ::= SEQUENCE {
currentMapHexSlot MapSlotIndex,
currentMapHexPort GenPortID,
currentMapHexData OCTET STRING
}
currentMapHexSlot OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { currentMapHexEntry 1 }
currentMapHexPort OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~N"
::= { currentMapHexEntry 2 }
currentMapHexData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current map data in Hex"
::= { currentMapHexEntry 3 }
--
-- Channel Map Hex Table
--
channelMapHexTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelMapHexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Mapping for TSI in Hex."
::= { channelMap 13 }
channelMapHexEntry OBJECT-TYPE
SYNTAX ChannelMapHexEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel Mapping for TSI."
INDEX { ccMapHexIndex ,
ccMapHexSlot ,
ccMapHexPort }
::= { channelMapHexTable 1 }
ChannelMapHexEntry ::= SEQUENCE {
ccMapHexIndex INTEGER,
ccMapHexSlot MapSlotIndex,
ccMapHexPort MapPortID,
ccMapHexData OCTET STRING
}
ccMapHexIndex OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TSI Map index."
::= { channelMapHexEntry 1 }
ccMapHexSlot OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { channelMapHexEntry 2 }
ccMapHexPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~N"
::= { channelMapHexEntry 3 }
ccMapHexData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Map data in Hex"
::= { channelMapHexEntry 4 }
--
-- Signaling/Data Display Table
--
signalingDataDispTable OBJECT-TYPE
SYNTAX SEQUENCE OF SignalingDataDispEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Signaling/data display table."
::= { channelMap 14 }
signalingDataDispEntry OBJECT-TYPE
SYNTAX SignalingDataDispEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Signaling/data display entry."
INDEX { sigDataDispSlot , sigDataDispPort , sigDataDispTS }
::= { signalingDataDispTable 1 }
SignalingDataDispEntry ::= SEQUENCE {
sigDataDispSlot MapSlotIndex,
sigDataDispPort GenPortID,
sigDataDispTS INTEGER,
sigDataDispType INTEGER,
currentRxSignaling INTEGER
}
sigDataDispSlot OBJECT-TYPE
SYNTAX MapSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { signalingDataDispEntry 1 }
sigDataDispPort OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port"
::= { signalingDataDispEntry 2 }
sigDataDispTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { signalingDataDispEntry 3 }
sigDataDispType OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
signal(3),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot type."
::= { signalingDataDispEntry 4 }
currentRxSignaling OBJECT-TYPE
SYNTAX INTEGER {
s0000(0),
s0001(1),
s0010(2),
s0011(3),
s0100(4),
s0101(5),
s0110(6),
s0111(7),
s1000(8),
s1001(9),
s1010(10),
s1011(11),
s1100(12),
s1101(13),
s1110(14),
s1111(15),
na(16)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received signaling."
::= { signalingDataDispEntry 5 }
--
-- Signaling Convertion Setup Table
--
sigConvertSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigConvertSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Signaling convertion setup table."
::= { channelMap 15 }
sigConvertSetupEntry OBJECT-TYPE
SYNTAX SigConvertSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Signaling convertion setup entry."
INDEX { sigConvertTableIndex }
::= { sigConvertSetupTable 1 }
SigConvertSetupEntry ::= SEQUENCE {
sigConvertTableIndex INTEGER,
sigConvertTableName DisplayString,
sigc0000 SignalingBit,
sigc0001 SignalingBit,
sigc0010 SignalingBit,
sigc0011 SignalingBit,
sigc0100 SignalingBit,
sigc0101 SignalingBit,
sigc0110 SignalingBit,
sigc0111 SignalingBit,
sigc1000 SignalingBit,
sigc1001 SignalingBit,
sigc1010 SignalingBit,
sigc1011 SignalingBit,
sigc1100 SignalingBit,
sigc1101 SignalingBit,
sigc1110 SignalingBit,
sigc1111 SignalingBit
}
sigConvertTableIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Table Index."
::= { sigConvertSetupEntry 1 }
sigConvertTableName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Table Namee"
::= { sigConvertSetupEntry 2 }
sigc0000 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 3 }
sigc0001 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 4 }
sigc0010 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 5 }
sigc0011 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 6 }
sigc0100 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 7 }
sigc0101 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 8 }
sigc0110 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 9 }
sigc0111 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 10 }
sigc1000 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 11 }
sigc1001 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 12 }
sigc1010 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 13 }
sigc1011 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 14 }
sigc1100 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 15 }
sigc1101 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 16 }
sigc1110 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 17 }
sigc1111 OBJECT-TYPE
SYNTAX SignalingBit
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Signaling."
::= { sigConvertSetupEntry 18 }
--==============================================================
--
-- tsi Data Cas In Out Table
--
tsiDataCasInOutTable OBJECT IDENTIFIER ::= { channelMap 16 }
tsiDataCasInOutcommand OBJECT-TYPE
SYNTAX INTEGER {
indata(1),
incas(2),
outdata(3),
outcas(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tsi Data Cas In Out command."
::= {tsiDataCasInOutTable 1 }
tsiDataCasInOutset OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tsi Data Cas In Out set."
::= {tsiDataCasInOutTable 2 }
tsiDataCasInOutget OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tsi Data Cas In Out set."
::= {tsiDataCasInOutTable 3 }
--
-- slot Model Table
--
slotModelTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlotModelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display slot model type"
::= { controller 9 }
slotModelEntry OBJECT-TYPE
SYNTAX SlotModelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot model entry"
INDEX { ccSlotIndex }
::= { slotModelTable 1 }
SlotModelEntry ::= SEQUENCE {
ccSlotIndex GenSlotID,
ccModelType GenModelType,
ccComment DisplayString,
ccCardMode DisplayString,
ccRegisteredModel GenModelType,
ccCardSerial INTEGER,
ccCardState INTEGER
}
ccSlotIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { slotModelEntry 1 }
ccModelType OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of current plug-in card"
::= { slotModelEntry 2 }
ccComment OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Comment of current plug-in card"
::= { slotModelEntry 3 }
ccCardMode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card mode of current plug-in card"
::= { slotModelEntry 4 }
ccRegisteredModel OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Registered model in this slot"
::= { slotModelEntry 7 }
ccCardSerial OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card serial number"
::= { slotModelEntry 8 }
ccCardState OBJECT-TYPE
SYNTAX INTEGER {
empty(1),
initializing(2),
working(3),
unplugged(4),
failed(5),
unknownCard(6),
brandMismatch(11),
systemMismatch(12),
cardTypeMismatch(13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card state"
::= { slotModelEntry 9 }
--
-- Dual Power Table
--
dualPowerTable OBJECT IDENTIFIER ::= { controller 10 }
power1AC OBJECT-TYPE
SYNTAX INTEGER {
none(1),
exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power1 Hardware Existence"
::= { dualPowerTable 1 }
power2AC OBJECT-TYPE
SYNTAX INTEGER {
none(1),
exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power2 Hardware Existence"
::= { dualPowerTable 2 }
power1Status OBJECT-TYPE
SYNTAX INTEGER {
off(1),
dc-100w(2),
dc-150w(3),
fail(4),
ac(5),
none(6),
dc-125v(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Power1 Status"
::= { dualPowerTable 3 }
power2Status OBJECT-TYPE
SYNTAX INTEGER {
off(1),
dc-100w(2),
dc-150w(3),
fail(4),
ac(5),
none(6),
dc-125v(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Power2 Status"
::= { dualPowerTable 4 }
powerConsumption OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total (Maximum) power consumption (Estimation in Watt)"
::= { dualPowerTable 5 }
fan1Status OBJECT-TYPE
SYNTAX INTEGER {
good(1),
fail-or-not-exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fan 1 Status"
::= { dualPowerTable 6 }
fan2Status OBJECT-TYPE
SYNTAX INTEGER {
good(1),
fail-or-not-exist(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fan 1 Status"
::= { dualPowerTable 7 }
power1Setup OBJECT-TYPE
SYNTAX INTEGER {
pwr-48V-DC(1),
pwr-125V-DC(2),
pwr-AC(3),
pwr-24V-DC(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Power card 1 Setup"
::= { dualPowerTable 8 }
power2Setup OBJECT-TYPE
SYNTAX INTEGER {
pwr-48V-DC(1),
pwr-125V-DC(2),
pwr-AC(3),
pwr-24V-DC(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Power card 2 Setup"
::= { dualPowerTable 9 }
c1Temperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CTRL 1 (left) Temperature"
::= { dualPowerTable 11 }
c1RelativeHumidity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CTRL 1 (left) Relative Humidity"
::= { dualPowerTable 12 }
c2Temperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CTRL 2 (right) Temperature"
::= { dualPowerTable 13 }
c2RelativeHumidity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CTRL 2 (right) Relative Humidity"
::= { dualPowerTable 14 }
dpwmInputVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM input volatge"
::= { dualPowerTable 15 }
dpwmTemperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM Temperature"
::= { dualPowerTable 16 }
dpwmCH0Voltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch0 volatge"
::= { dualPowerTable 17 }
dpwmCH1Voltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch1 volatge"
::= { dualPowerTable 18 }
dpwmCH2Voltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch2 volatge"
::= { dualPowerTable 19 }
dpwmCH3Voltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch3 volatge"
::= { dualPowerTable 20 }
dpwmCH0Current OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch0 Current"
::= { dualPowerTable 21 }
dpwmCH1Current OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch1 Current"
::= { dualPowerTable 22 }
dpwmCH2Current OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch2 Current"
::= { dualPowerTable 23 }
dpwmCH3Current OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DPWM ch3 Current"
::= { dualPowerTable 24 }
--
-- LINK BACKUP
--
linkbackup OBJECT IDENTIFIER ::= { controller 11 }
--
-- Link Backup Table
--
backupTable OBJECT IDENTIFIER ::= { linkbackup 1 }
ccBackupfun OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on1for1(2),
on1plus1(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable Backup Function"
::= { backupTable 1 }
ccBackupMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup Function Mode"
::= { backupTable 2 }
ccLinkAbackup OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup Link Of Link A"
::= { backupTable 3 }
ccLinkBbackup OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup Link Of Link B"
::= { backupTable 4 }
ccLinkCbackup OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup Link Of Link C"
::= { backupTable 5 }
ccLinkDbackup OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup Link Of Link D"
::= { backupTable 6 }
ccLinkForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
none(0),
link-A(1),
link-B(2),
link-C(3),
link-D(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force switch for non-revertive mode"
::= { backupTable 7 }
--
-- backup status Table
--
backupStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF BackupStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display slot model type"
::= { linkbackup 2 }
backupStatusEntry OBJECT-TYPE
SYNTAX BackupStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link status entry"
INDEX { bkIndex }
::= { backupStatusTable 1 }
BackupStatusEntry ::= SEQUENCE {
bkIndex BackupLink,
bkModelType INTEGER,
bkBackupLink BackupLink,
bkBackupFun INTEGER,
bkStatus INTEGER
}
bkIndex OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { backupStatusEntry 1 }
bkModelType OBJECT-TYPE
SYNTAX INTEGER {
fe1(1),
ft1(2),
fom(30),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port model type"
::= { backupStatusEntry 2 }
bkBackupLink OBJECT-TYPE
SYNTAX BackupLink
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { backupStatusEntry 3 }
bkBackupFun OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"link backup function status"
::= { backupStatusEntry 4 }
bkStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
working(2),
stand-by(3),
normal(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"link backup function status"
::= { backupStatusEntry 5 }
--
-- New Backup Table
--
newBackupTable OBJECT-TYPE
SYNTAX SEQUENCE OF NewBackupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"New backup table"
::= { linkbackup 3 }
newBackupEntry OBJECT-TYPE
SYNTAX NewBackupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"New backup entry"
INDEX { newBackupIndex }
::= { newBackupTable 1 }
NewBackupEntry ::= SEQUENCE {
newBackupIndex NewBackupLink,
newBkModelType INTEGER,
newBackupLink NewBackupLink,
newBackupForce INTEGER,
newBkBackupFun INTEGER,
newBkStatus INTEGER
}
newBackupIndex OBJECT-TYPE
SYNTAX NewBackupLink
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Backup Index"
::= { newBackupEntry 1 }
newBkModelType OBJECT-TYPE
SYNTAX INTEGER {
fe1(1),
ft1(2),
fom(30),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"slot model type"
::= { newBackupEntry 2 }
newBackupLink OBJECT-TYPE
SYNTAX NewBackupLink
ACCESS read-write
STATUS mandatory
DESCRIPTION
"backup link"
::= { newBackupEntry 3 }
newBackupForce OBJECT-TYPE
SYNTAX INTEGER {
no(1),
force-switch(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"force switch"
::= { newBackupEntry 4 }
newBkBackupFun OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"link backup function status"
::= { newBackupEntry 5 }
newBkStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
working(2),
stand-by(3),
normal(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"link backup function status"
::= { newBackupEntry 6 }
--
-- upload/download file Table
--
fileTransferTable OBJECT IDENTIFIER ::= { controller 12 }
tftpServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of tftp server"
::= { fileTransferTable 1 }
tftpFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"File name for upload/download"
::= { fileTransferTable 2 }
fileTransferType OBJECT-TYPE
SYNTAX INTEGER {
clear-status(1),
copy-controller-firmware-to-redundant(2),
download-controller-firmware(11),
download-system-configugration(13),
-- download-bootup-code(14),
-- download-fae-package(15),
download-RTAB-config(16),
-- upload-controller-firmware1(21),
-- upload-controller-firmware2(22),
upload-system-configugration(23),
upload-fae-info(25),
upload-RTAB-startup-config(26),
upload-RTAB-working-config(27),
-- download-RTR-card(69),
-- download-TS-card(70),
download-ATM-card(71),
download-QE1-card(81),
download-MQE1-card(82),
download-GSHDSL-card(83),
download-HDSLA-card(84),
download-DTEA-card(85),
download-DTU-card(86),
download-X50-card(87),
download-8X50-card(88),
download-OMNIBUS-card(89),
download-3E1-card(90),
download-TDMoE-card(91),
download-8DBRA-card(94),
download-8UDTE-card(95),
download-RTA-firmware(96),
download-RTB-firmware(100),
download-FE1-firmware(102),
download-FT1-firmware(103),
download-M4TE-firmware(104),
download-QFXO-firmware(111),
download-QFXO-FPGA(112),
download-FXS-firmware(113),
download-FXO-firmware(114),
download-MAG-firmware(115),
download-EM-firmware(116),
download-QFXS-FPGA(117),
download-QFXS-firmware(118),
download-FXO-FPGA(119),
download-EM-FPGA(121),
download-MAG-FPGA(123),
download-ECA-card(129),
download-RS232A-card(130),
download-ABRA-card(131),
download-TTA-firmware(132),
download-TTA-FPGA(133),
download-SDTE-firmware(134),
download-SDTE-FPGA(135),
download-6UDTEA-card(138),
download-6CDA-firmware(139),
download-6CDA-FPGA(140),
download-QMAG-firmware(142),
download-QMAG-FPGA(143),
download-3RS232-card(145),
na(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upload/download type"
::= { fileTransferTable 3 }
uploadDownloadCard OBJECT-TYPE
SYNTAX INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
controller(32),
na(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upload/download card"
::= { fileTransferTable 4 }
transferCommand OBJECT-TYPE
SYNTAX INTEGER {
none(1),
start(2),
downloadFWandEnableUpgradeProtection(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upload/download command"
::= { fileTransferTable 5 }
transferPercentage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Upload/download percentage"
::= { fileTransferTable 6 }
transferErrorCode OBJECT-TYPE
SYNTAX INTEGER {
na(0),
ok(1),
in-transmit(2),
in-checksum(3),
in-write-flash(4),
in-send-to-card(5),
in-prepare-config-data(6),
in-enable-config(7),
in-sync-config(8),
other-see-message(9),
redundant-not-exist-or-sync(11),
redundant-no-response(12),
transmit-abort(13),
redundant-firmware-checksum-error(14),
other-transmit-in-progress(15),
program-flash-fail(16),
unmatched-version-or-structure(17),
fail-to-send-card(18),
redundant-model-not-correct(19),
image-too-large(21),
failed-to-erase-FLASH-memory(22),
failed-to-program-FLASH-memory(23),
unknow-TFTP-server-error(24),
checksum-error(25),
failed-to-read-data-in-FLASH-memory(26),
unable-to-download-configuration(27),
unmatch-firmware(28),
prepare-config-data-fail(29),
file-does-not-support-this-HW-version(30),
file-not-found(31),
access-violation(32),
disk-full-or-allocation-exceeded(33),
illegal-TFTP-operation(34),
unknown-transfer-ID(35),
file-already-exists(36),
no-such-user(37),
resources-not-available(38),
aborted-by-client-request(39),
timed-out(40),
connect-fail(41),
firmware-not-allow-copy-to-redundant(42),
firmware-serial-no-mismatch(43),
card-type-mismatch(51),
card-version-does-not-support-firmware-upgrade(52),
ptn-not-ready(53),
copy-to-standby-ptn(54),
irc2-transmit(55),
copy-to-working-ptn(56),
ok-need-cold-reset(101),
unknown-problem(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transfer percentage"
::= { fileTransferTable 7 }
transferMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Message of transfer process"
::= { fileTransferTable 8 }
--
-- Bit Error Rate Test Table
--
ctlBertTable OBJECT IDENTIFIER ::= { controller 14 }
ctlBertSlot OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT slot"
::= { ctlBertTable 1 }
ctlBertPort OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT port"
::= { ctlBertTable 2 }
ctlBertPattern OBJECT-TYPE
SYNTAX INTEGER {
-- off(1),
prbs2exp20-1(2),
prbs2exp15-1(3),
prbs2exp11-1(4),
prbs2exp9-1(5),
user-define(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT pattern"
::= { ctlBertTable 3 }
ctlSplitMode OBJECT-TYPE
SYNTAX INTEGER {
sendAIS(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT split mode"
::= { ctlBertTable 4 }
ctlBertChannel OBJECT-TYPE
SYNTAX INTEGER {
mapped(1),
full(2),
select(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT channel"
::= { ctlBertTable 5 }
ctlUserPattern OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT user pattern"
::= { ctlBertTable 6 }
ctlBertAction OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
start(2),
reset(3),
insert-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT action"
::= { ctlBertTable 7 }
ctlChannelInBert OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel in BERT"
::= { ctlBertTable 8 }
ctlBertStatus OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { ctlBertTable 9 }
ctlBertElapsedTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Elapsed Time (s)"
::= { ctlBertTable 10 }
ctlBertBitError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Bit Error"
::= { ctlBertTable 11 }
ctlBertErrorSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Error Seconds"
::= { ctlBertTable 12 }
ctlBertSeveralErrorSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT SES"
::= { ctlBertTable 13 }
ctlBertPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Period(in seconds) of BERT"
::= { ctlBertTable 14 }
ctlBertDirection OBJECT-TYPE
SYNTAX INTEGER {
to-line(1),
to-mapped(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT direction"
::= { ctlBertTable 15 }
ctlBertMap OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT map 32 chars, i=idle, 1=map. Ex:
i1111iiiiiiiiiiiiiiiiiiiiiiiiiii => send BERT in TS1~4"
::= { ctlBertTable 16 }
-- RIKER 2013 NFS-13000090
ctlBertUnsyncSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT US"
::= { ctlBertTable 17 }
--
-- SSM Clock Source Table
--
ssmClockSourceTable OBJECT IDENTIFIER ::= { controller 15 }
ssmFirstClock OBJECT-TYPE
SYNTAX SSMClockIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SSM First Clock setting"
::= { ssmClockSourceTable 1 }
ssmSecondClock OBJECT-TYPE
SYNTAX SSMClockIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SSM Second Clock setting"
::= { ssmClockSourceTable 2 }
ssmThirdClock OBJECT-TYPE
SYNTAX SSMClockIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SSM Third Clock setting"
::= { ssmClockSourceTable 3 }
ssmCurrentClock OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
internal(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Clock source"
::= { ssmClockSourceTable 4 }
ssmClockStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
loss(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clock status indicate current clock status."
::= { ssmClockSourceTable 5 }
ssmInternalSSMmsg OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internal Clock SSM Message"
::= { ssmClockSourceTable 6 }
ssmExternalSSMmsg OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock SSM Message"
::= { ssmClockSourceTable 7 }
ssmLineSSMmsg OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Clock SSM Message"
::= { ssmClockSourceTable 8 }
ssmExtClockType OBJECT-TYPE
SYNTAX INTEGER {
e1Crc(1),
e1Fas(2),
t1Esf(3),
t1D4(4),
ext2048Khz(5),
na(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock Type."
::= { ssmClockSourceTable 9 }
ssmExtClockImpedance OBJECT-TYPE
SYNTAX INTEGER {
ext75ohm(1),
ext120ohm(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock Impedance."
::= { ssmClockSourceTable 10 }
ssmExtClockSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
na(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock SSM Sa-bit."
::= { ssmClockSourceTable 11 }
ssmCurrentSSMmsg OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current (send out) SSM."
::= { ssmClockSourceTable 12 }
--
-- Port State Control Table
--
--
-- portStateControlTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF PortStateControlEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Port State Control Table"
-- ::= { controller 16 }
--
-- portStateControlEntry OBJECT-TYPE
-- SYNTAX PortStateControlEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Port State Control Entry"
-- INDEX { pscSlotIndex, pscPortIndex }
-- ::= { portStateControlTable 1 }
--
-- PortStateControlEntry ::=
-- SEQUENCE {
-- pscSlotIndex
-- GenSlotID,
-- pscPortIndex
-- GenPortID,
-- pscModelType
-- GenModelType,
-- pscPortState
-- INTEGER
-- }
--
-- pscSlotIndex OBJECT-TYPE
-- SYNTAX GenSlotID
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Port State Control: Slot Index"
-- ::= { portStateControlEntry 1 }
--
-- pscPortIndex OBJECT-TYPE
-- SYNTAX GenPortID
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Port State Control: Port Index"
-- ::= { portStateControlEntry 2 }
--
-- pscModelType OBJECT-TYPE
-- SYNTAX GenModelType
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Port State Control: Model Type"
-- ::= { portStateControlEntry 3 }
--
-- pscPortState OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(1),
-- enable(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Disable : no alarm, performance, protection;
-- Enable : normal work;
-- Diagnostic: in protection, allow test."
-- ::= { portStateControlEntry 4 }
--
-- PDH Ring Protection
--
pdhRingProtection OBJECT IDENTIFIER ::= { controller 17 }
pdhRingControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
deactivated(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable PDH Ring Protection Function"
::= { pdhRingProtection 1 }
pdhRingSwitchingInterval OBJECT-TYPE
SYNTAX INTEGER (5..180)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PDH Ring Protection Switching Interval (Seconds)"
::= { pdhRingProtection 2 }
pdhRingStation OBJECT-TYPE
SYNTAX INTEGER {
slave(1),
master(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Station type in the Ring"
::= { pdhRingProtection 3 }
pdhRingAlarmFiltering OBJECT-TYPE
SYNTAX INTEGER (0..180)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PDH Ring Protection Alarm Filtering (Seconds)"
::= { pdhRingProtection 4 }
--
-- PDH Ring Port Setup Table
--
pdhRingPortSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PDHRingPortSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PDH Ring Port Setup Table"
::= { pdhRingProtection 5 }
pdhRingPortSetupEntry OBJECT-TYPE
SYNTAX PDHRingPortSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PDH Ring Port Setup Entry"
INDEX { pdhRingSlotIndex , pdhRingPortIndex }
::= { pdhRingPortSetupTable 1 }
PDHRingPortSetupEntry ::= SEQUENCE {
pdhRingSlotIndex GenSlotID,
pdhRingPortIndex GenPortID,
pdhRingModelType GenModelType,
pdhRingPortProtection INTEGER,
pdhRingPortStatus INTEGER,
pdhRingPortDiagnostic INTEGER
}
pdhRingSlotIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PDH Ring Setup: Slot Index"
::= { pdhRingPortSetupEntry 1 }
pdhRingPortIndex OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PDH Ring Setup: Port Index"
::= { pdhRingPortSetupEntry 2 }
pdhRingModelType OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PDH Ring Setup: Model Type"
::= { pdhRingPortSetupEntry 3 }
pdhRingPortProtection OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
xxxxxx(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PDH Ring Setup: Enable/Disable"
::= { pdhRingPortSetupEntry 4 }
pdhRingPortStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
normal(2),
in-protect(3),
xxxxxx(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PDH Ring Port Status"
::= { pdhRingPortSetupEntry 5 }
pdhRingPortDiagnostic OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
diag1-send-ais(2),
diag2-test-mode(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PDH Ring Port Diagnostic"
::= { pdhRingPortSetupEntry 6 }
--
-- QE1/QT1/mQE1 1:1 Pair Protection
--
qe1PairProtectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF Qe1PairProtectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE1/QT1/mQE1 1:1 Pair Protection Table"
::= { controller 18 }
qe1PairProtectionEntry OBJECT-TYPE
SYNTAX Qe1PairProtectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE1/QT1/mQE1 1:1 Pair Protection Entry"
INDEX { qe1PairSlotIndex , qe1PairPortIndex }
::= { qe1PairProtectionTable 1 }
Qe1PairProtectionEntry ::= SEQUENCE {
qe1PairSlotIndex INTEGER,
qe1PairPortIndex FourPortID,
qe1PairModelType GenModelType,
qe1PairPortProtection INTEGER,
qe1PairPortStatus INTEGER,
qe1PairPortForceSwitch INTEGER
}
qe1PairSlotIndex OBJECT-TYPE
SYNTAX INTEGER {
slot-a-b(1),
slot-c-d(2),
slot-1-2(3),
slot-3-4(4),
slot-5-6(5),
slot-7-8(6),
slot-9-10(7),
slot-11-12(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection: Slot Index"
::= { qe1PairProtectionEntry 1 }
qe1PairPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection: Port Index"
::= { qe1PairProtectionEntry 2 }
qe1PairModelType OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection: Model Type"
::= { qe1PairProtectionEntry 3 }
qe1PairPortProtection OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line-non-revertive(3),
line-revertive(4),
one-plus-one-non-revertive(5),
one-plus-one-revertive(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection:
1 = disable,
2 = circuit (Y cable) protection,
3 = non revertible line protection,
4 = revertible line protection,
5 = 1+1 non revertible line protection,
6 = 1+1 revertible line protection
"
::= { qe1PairProtectionEntry 4 }
qe1PairPortStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
normal(2),
in-protect(3),
xxxxxx(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection: Status"
::= { qe1PairProtectionEntry 5 }
qe1PairPortForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
force-switch(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 1:1 Pair Protection: Force switch"
::= { qe1PairProtectionEntry 6 }
--
-- DS0-SNCP Protection
--
ds0sncpProtection OBJECT IDENTIFIER ::= { controller 19 }
ds0sncpEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
clear-performance(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP Enable/Disable."
::= { ds0sncpProtection 1 }
ds0sncpMap OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP Using TSI Map."
::= { ds0sncpProtection 2 }
ds0sncpActionResponse OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP action response."
::= { ds0sncpProtection 3 }
--
-- DS0-SNCP Creation
--
ds0sncpCreationTable OBJECT IDENTIFIER ::= { ds0sncpProtection 4 }
dsProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected Slot A~D, 1~12."
::= { ds0sncpCreationTable 1 }
dsProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected Port 1~12."
::= { ds0sncpCreationTable 2 }
dsProtectedStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected start time slot index."
::= { ds0sncpCreationTable 3 }
dsChannelNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Total channel number."
::= { ds0sncpCreationTable 4 }
dsPrimarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 slot number."
::= { ds0sncpCreationTable 5 }
dsPrimaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 port number."
::= { ds0sncpCreationTable 6 }
dsPrimaryStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 start time slot."
::= { ds0sncpCreationTable 9 }
dsSecondarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 slot number."
::= { ds0sncpCreationTable 11 }
dsSecondaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 port number."
::= { ds0sncpCreationTable 12 }
dsSecondaryStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 start time slot."
::= { ds0sncpCreationTable 15 }
dsSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { ds0sncpCreationTable 16 }
dsSetCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
check-set(1),
force-set(2),
force-switch(3),
delete-1(4),
delete-all(5),
clearAndSet(6),
lock-working(11),
lock-primary(12),
lock-secondary(13),
unlock(14),
change-switch-mode(21)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set command:
1: check and set DS0-SNCP;
2: force set DS0-SNCP;
3: force switch a DS0-SNCP;
4: delete a DS0-SNCP;
5: delete all;
11: lock on working;
12: lock on primary;
13: lock on secondary;
14: unlock"
::= { ds0sncpCreationTable 17 }
dsDataVoice OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Data or Voice"
::= { ds0sncpCreationTable 18 }
dsCircuitGroup OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"group number for protected port, 0 means individual."
::= { ds0sncpCreationTable 19 }
dsBackupEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
notSupported(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup disable/enable"
::= { ds0sncpCreationTable 20 }
dsBackupSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select backup Slot A~D, 1~12."
::= { ds0sncpCreationTable 21 }
dsBackupPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select backup Port 1~12."
::= { ds0sncpCreationTable 22 }
dsBackupStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select backup start time slot index."
::= { ds0sncpCreationTable 23 }
--
-- DS0-SNCP Information
--
ds0sncpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ds0sncpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP Protection Information Table"
::= { ds0sncpProtection 5 }
ds0sncpInfoEntry OBJECT-TYPE
SYNTAX Ds0sncpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP Protection Information Entry"
INDEX { ds0sncpInfoIndex }
::= { ds0sncpInfoTable 1 }
Ds0sncpInfoEntry ::= SEQUENCE {
ds0sncpInfoIndex INTEGER,
dsiProtectedSlot MapSetSlot,
dsiProtectedPort MapPortID,
dsiProtectedTS INTEGER,
dsiPrimarySlot LargeSlotIndex,
dsiPrimaryPort ThreePortID,
dsiPrimaryTS INTEGER,
dsiSecondarySlot LargeSlotIndex,
dsiSecondaryPort ThreePortID,
dsiSecondaryTS INTEGER,
dsiSwitchMode INTEGER,
dsiDataVoice INTEGER,
dsiWorkingOn INTEGER,
dsiForceSwitch INTEGER,
dsiDeleteProtection INTEGER
}
ds0sncpInfoIndex OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP Information Index."
::= { ds0sncpInfoEntry 1 }
dsiProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Slot A~D, 1~12."
::= { ds0sncpInfoEntry 2 }
dsiProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Port 1~12."
::= { ds0sncpInfoEntry 3 }
dsiProtectedTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected time slot."
::= { ds0sncpInfoEntry 4 }
dsiPrimarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 slot number."
::= { ds0sncpInfoEntry 5 }
dsiPrimaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 port number."
::= { ds0sncpInfoEntry 6 }
dsiPrimaryTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 time slot."
::= { ds0sncpInfoEntry 7 }
dsiSecondarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 slot number."
::= { ds0sncpInfoEntry 8 }
dsiSecondaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 port number."
::= { ds0sncpInfoEntry 9 }
dsiSecondaryTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 start time slot."
::= { ds0sncpInfoEntry 10 }
dsiSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { ds0sncpInfoEntry 11 }
dsiWorkingOn OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working on primary or secondary."
::= { ds0sncpInfoEntry 12 }
dsiForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
no(1),
force-switch(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force switch to standby TS."
::= { ds0sncpInfoEntry 13 }
dsiDeleteProtection OBJECT-TYPE
SYNTAX INTEGER {
no(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete protection."
::= { ds0sncpInfoEntry 14 }
dsiDataVoice OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Data or Voice"
::= { ds0sncpInfoEntry 15 }
--
-- DS0-SNCP Performance Table
--
ds0sncpPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ds0sncpPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP Performance Table"
::= { ds0sncpProtection 6 }
ds0sncpPerfEntry OBJECT-TYPE
SYNTAX Ds0sncpPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP Performance Entry"
INDEX { ds0sncpPerfIndex }
::= { ds0sncpPerfTable 1 }
Ds0sncpPerfEntry ::= SEQUENCE {
ds0sncpPerfIndex INTEGER,
dspProtectedSlot MapSetSlot,
dspProtectedPort MapPortID,
dspProtectedTS INTEGER,
dspCurrentDaySeconds INTEGER,
dspCurrentDayAS INTEGER,
dspCurrentDayUAS INTEGER,
dspValidDayInterval INTEGER
}
ds0sncpPerfIndex OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP Performance Index."
::= { ds0sncpPerfEntry 1 }
dspProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Slot A~D, 1~12."
::= { ds0sncpPerfEntry 2 }
dspProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Port 1~12."
::= { ds0sncpPerfEntry 3 }
dspProtectedTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected time slot."
::= { ds0sncpPerfEntry 4 }
dspCurrentDaySeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current day elapsed seconds"
::= { ds0sncpPerfEntry 5 }
dspCurrentDayAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current day available seconds"
::= { ds0sncpPerfEntry 6 }
dspCurrentDayUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current day unavailable seconds"
::= { ds0sncpPerfEntry 7 }
dspValidDayInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Valid days Interval number"
::= { ds0sncpPerfEntry 8 }
--
-- DS0-SNCP 7 Days Performance Table
--
ds0sncp7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ds0sncp7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP 7 days performance table."
::= { ds0sncpProtection 7 }
ds0sncp7DaysPerfEntry OBJECT-TYPE
SYNTAX Ds0sncp7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP 7 days performance entry."
INDEX { dsdPerfIndex , dsdDayIndex }
::= { ds0sncp7DaysPerfTable 1 }
Ds0sncp7DaysPerfEntry ::= SEQUENCE {
dsdPerfIndex INTEGER,
dsdDayIndex INTEGER,
dsdDateStrIndex DisplayString,
dsdProtectedSlot MapSetSlot,
dsdProtectedPort MapPortID,
dsdProtectedTS INTEGER,
dsdDayAS INTEGER,
dsdDayUAS INTEGER
}
dsdPerfIndex OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP Performance Index."
::= { ds0sncp7DaysPerfEntry 1 }
dsdDayIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP Performance Day Index."
::= { ds0sncp7DaysPerfEntry 2 }
dsdDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { ds0sncp7DaysPerfEntry 3 }
dsdProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Slot A~D, 1~12."
::= { ds0sncp7DaysPerfEntry 4 }
dsdProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Port 1~12."
::= { ds0sncp7DaysPerfEntry 5 }
dsdProtectedTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected time slot."
::= { ds0sncp7DaysPerfEntry 6 }
dsdDayAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day available seconds"
::= { ds0sncp7DaysPerfEntry 7 }
dsdDayUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day unavailable seconds"
::= { ds0sncp7DaysPerfEntry 8 }
--
-- New DS0-SNCP Information
--
newDs0sncpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF NewDs0sncpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"New DS0-SNCP Protection Information Table"
::= { ds0sncpProtection 8 }
newDs0sncpInfoEntry OBJECT-TYPE
SYNTAX NewDs0sncpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"New DS0-SNCP Protection Information Entry"
INDEX { ndsiProtectedSlot , ndsiProtectedPort , ndsiProtectedTS }
::= { newDs0sncpInfoTable 1 }
NewDs0sncpInfoEntry ::= SEQUENCE {
ndsiProtectedSlot MapSetSlot,
ndsiProtectedPort MapPortID,
ndsiProtectedTS INTEGER,
ndsiPrimarySlot LargeSlotIndex,
ndsiPrimaryPort ThreePortID,
ndsiPrimaryTS INTEGER,
ndsiSecondarySlot LargeSlotIndex,
ndsiSecondaryPort ThreePortID,
ndsiSecondaryTS INTEGER,
ndsiSwitchMode INTEGER,
ndsiDataVoice INTEGER,
ndsiWorkingOn INTEGER,
ndsiDispIndex INTEGER,
ndsiCircuitGroup INTEGER,
ndsiPrimaryStatus INTEGER,
ndsiSecondaryStatus INTEGER,
ndsiBackupSlot MapSetSlot,
ndsiBackupPort MapPortID,
ndsiBackupTS INTEGER
}
ndsiProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Slot A~D, 1~12."
::= { newDs0sncpInfoEntry 1 }
ndsiProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected Port 1~12."
::= { newDs0sncpInfoEntry 2 }
ndsiProtectedTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protected time slot."
::= { newDs0sncpInfoEntry 3 }
ndsiPrimarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 slot number."
::= { newDs0sncpInfoEntry 4 }
ndsiPrimaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 port number."
::= { newDs0sncpInfoEntry 5 }
ndsiPrimaryTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary 3E1/3T1 time slot."
::= { newDs0sncpInfoEntry 6 }
ndsiSecondarySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 slot number."
::= { newDs0sncpInfoEntry 7 }
ndsiSecondaryPort OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 port number."
::= { newDs0sncpInfoEntry 8 }
ndsiSecondaryTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary 3E1/3T1 start time slot."
::= { newDs0sncpInfoEntry 9 }
ndsiSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { newDs0sncpInfoEntry 10 }
ndsiDataVoice OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Data or Voice"
::= { newDs0sncpInfoEntry 11 }
ndsiWorkingOn OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working on primary or secondary."
::= { newDs0sncpInfoEntry 12 }
ndsiDispIndex OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0-SNCP Display Index."
::= { newDs0sncpInfoEntry 13 }
ndsiCircuitGroup OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"group number for protected port, 0 means individual."
::= { newDs0sncpInfoEntry 14 }
ndsiPrimaryStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary TS status."
::= { newDs0sncpInfoEntry 15 }
ndsiSecondaryStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary TS status."
::= { newDs0sncpInfoEntry 16 }
ndsiBackupSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Backup Slot A~D, 1~12."
::= { newDs0sncpInfoEntry 17 }
ndsiBackupPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Backup Port 1~12."
::= { newDs0sncpInfoEntry 18 }
ndsiBackupTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Backup time slot."
::= { newDs0sncpInfoEntry 19 }
--
-- Current Active Alarm Summary Table
--
currentActiveAlarmSummaryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CurrentActiveAlarmSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Current Active Alarm Summary"
::= {controller 21}
currentActiveAlarmSummaryEntry OBJECT-TYPE
SYNTAX CurrentActiveAlarmSummaryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Active Alarm Summary Entry"
INDEX { ccCurrentActiveAlarmSummaryIndex }
::= { currentActiveAlarmSummaryTable 1 }
CurrentActiveAlarmSummaryEntry ::= SEQUENCE{
ccCurrentActiveAlarmSummaryIndex INTEGER (1..40),
ccCaasAlarmDesString DisplayString (SIZE(0..255)),
ccCaasAlarmModel AlarmModelType,
ccCaasAlarmSlot AlarmSlotIndex,
ccCaasAlarmPort AlarmPort,
ccCaasAlarmType AlarmType,
ccCaasAlarmSeverity AlarmSeverityDisp,
ccCaasAlarmStatus INTEGER,
ccCaasAlarmLink AlarmLink
}
ccCurrentActiveAlarmSummaryIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Crrent Active Alarm Summary Index"
::= {currentActiveAlarmSummaryEntry 1 }
ccCaasAlarmDesString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Description String"
::= {currentActiveAlarmSummaryEntry 2 }
ccCaasAlarmModel OBJECT-TYPE
SYNTAX AlarmModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Model"
::= { currentActiveAlarmSummaryEntry 3 }
ccCaasAlarmSlot OBJECT-TYPE
SYNTAX AlarmSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Slot"
::= {currentActiveAlarmSummaryEntry 4 }
ccCaasAlarmPort OBJECT-TYPE
SYNTAX AlarmPort
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Port"
::= { currentActiveAlarmSummaryEntry 5 }
ccCaasAlarmType OBJECT-TYPE
SYNTAX AlarmType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Type"
::= {currentActiveAlarmSummaryEntry 6 }
ccCaasAlarmSeverity OBJECT-TYPE
SYNTAX AlarmSeverityDisp
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Severity"
::= { currentActiveAlarmSummaryEntry 7 }
ccCaasAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
cleared(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Status"
::= { currentActiveAlarmSummaryEntry 8 }
ccCaasAlarmLink OBJECT-TYPE
SYNTAX AlarmLink
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CAAS Alarm Link"
::= { currentActiveAlarmSummaryEntry 9 }
--
-- sntpInfoTable
--
sntpInfoTable OBJECT IDENTIFIER ::= { controller 22 }
sntpInfoCurrnetServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current NTP Server "
::= {sntpInfoTable 1}
sntpInfoServerIPAddress1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" NTP Server IP Address"
::= {sntpInfoTable 2}
sntpInfoServerIPAddress2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" NTP Server IP Address "
::= {sntpInfoTable 3}
sntpInfoTimeZone OBJECT-TYPE
SYNTAX INTEGER{
utc(0),
utc1(1),
utc2(2),
utc3(3),
utc4(4),
utc5(5),
utc6(6),
utc7(7),
utc8(8),
utc9(9),
utc10(10),
utc11(11),
utc12(12),
utc-12(-12),
utc-11(-11),
utc-10(-10),
utc-9(-9),
utc-8(-8),
utc-7(-7),
utc-6(-6),
utc-5(-5),
utc-4(-4),
utc-3(-3),
utc-2(-2),
utc-1(-1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" UTC Time Zone "
::= {sntpInfoTable 4}
sntpInfoUpdateInterval OBJECT-TYPE
SYNTAX INTEGER (5..1440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNTP Update Interval (5~1440 Minutes)"
::= { sntpInfoTable 5 }
sntpInfoLastUpdateTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNTP Last Update Time"
::= { sntpInfoTable 6 }
sntpInfoFunction OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNTP enable/disable"
::= { sntpInfoTable 7 }
--
-- sysNetworkManagement
--
sysNetworkManagement OBJECT IDENTIFIER ::= { controller 23 }
sysNetIntfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysNetIntfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Network Interface Table"
::= { sysNetworkManagement 1 }
sysNetIntfEntry OBJECT-TYPE
SYNTAX SysNetIntfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Network Interface Entry"
INDEX { sysNiIndex }
::= { sysNetIntfTable 1 }
SysNetIntfEntry ::= SEQUENCE {
sysNiIndex INTEGER,
sysNiEnable INTEGER,
sysNiIPaddress IpAddress,
sysNiSubnetMask IpAddress,
sysNiFrame INTEGER,
sysNiInterface INTEGER
}
sysNiIndex OBJECT-TYPE
SYNTAX INTEGER {
lan(1),
wan(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LAN(ethernet), WAN(PPP/HDLC)"
::= { sysNetIntfEntry 1 }
sysNiEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable this NI"
::= { sysNetIntfEntry 2 }
sysNiIPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address"
::= { sysNetIntfEntry 3 }
sysNiSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"subnet mask"
::= { sysNetIntfEntry 4 }
sysNiFrame OBJECT-TYPE
SYNTAX INTEGER {
na(1),
hdlc(2),
ppp(3),
slip(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN: HDLC/PPP"
::= { sysNetIntfEntry 5 }
sysNiInterface OBJECT-TYPE
SYNTAX INTEGER {
rjElectric(1),
optical(2),
inband(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface"
::= { sysNetIntfEntry 6 }
-- system Network Management
sysGatewayIntf OBJECT-TYPE
SYNTAX INTEGER {
lan(1),
wan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway Interface"
::= { sysNetworkManagement 2 }
sysGatewayIPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"gateway IP"
::= { sysNetworkManagement 3 }
sysTelnetEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable Telnet"
::= { sysNetworkManagement 4 }
sysSSHEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable SSH"
::= { sysNetworkManagement 5 }
sysSSHStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
build-key(2),
normal(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SSH status"
::= { sysNetworkManagement 6 }
trapSystemIP OBJECT-TYPE
SYNTAX INTEGER {
-- auto(1),
lan(2),
wan(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap System IP"
::= { sysNetworkManagement 7 }
inbandUsesSlot OBJECT-TYPE
SYNTAX INTEGER {
slot-D(1),
slot-12(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Inband Uses Slot:
Slot-D : slot-D port 4 can not use unframe mode.
Slot-12: slot-12 port 4 can not use unframe mode, 4GH port 4 TS0 can not use."
::= { sysNetworkManagement 9 }
alarmTrapType OBJECT-TYPE
SYNTAX INTEGER {
vendor-spec(1),
assigned(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm/Trap type"
::= { sysNetworkManagement 10 }
trapObjectType OBJECT-TYPE
SYNTAX INTEGER {
vendor-spec(1),
individual(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap Object Type"
::= { sysNetworkManagement 11 }
-- RIKER 2013 NFS-13000080
networkMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap System IP"
::= { sysNetworkManagement 12 }
trapCompWindow OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"trap compress window: 0=disable, or 1~15 min"
::= { sysNetworkManagement 13 }
setMgmtIPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address"
::= { sysNetworkManagement 14 }
setMgmtSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"subnet mask"
::= { sysNetworkManagement 15 }
mgmtLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
na(0),
linkDown(1),
linkUp(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mgmt port link status"
::= { sysNetworkManagement 16 }
mgmtLinkSpeed OBJECT-TYPE
SYNTAX INTEGER {
na(0),
link10M(1),
link100M(2),
link1000M(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mgmt port link speed"
::= { sysNetworkManagement 17 }
redMgmtLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
na(0),
linkDown(1),
linkUp(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"redundant mgmt port link status"
::= { sysNetworkManagement 18 }
redMgmtLinkSpeed OBJECT-TYPE
SYNTAX INTEGER {
na(0),
link10M(1),
link100M(2),
link1000M(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"redundant mgmt port link speed"
::= { sysNetworkManagement 19 }
sysHTTPEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable HTTP"
::= { sysNetworkManagement 20 }
sysHTTPSEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable HTTPS"
::= { sysNetworkManagement 21 }
sysHTTPStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HTTP status"
::= { sysNetworkManagement 22 }
sysHTTPSStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HTTPS status"
::= { sysNetworkManagement 23 }
--
-- V1 Trap and community
--
v1TrapCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF V1TrapCommunityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SNMP V1 Trap and Community Table"
::= { sysNetworkManagement 8 }
v1TrapCommunityEntry OBJECT-TYPE
SYNTAX V1TrapCommunityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SNMP V1 Trap and Community Entry"
INDEX { trapIndex }
::= { v1TrapCommunityTable 1 }
V1TrapCommunityEntry ::= SEQUENCE {
trapIndex INTEGER,
trapIPaddress IpAddress,
trapCommunity DisplayString
}
trapIndex OBJECT-TYPE
SYNTAX INTEGER (1..5)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Trap Index 1-5"
::= { v1TrapCommunityEntry 1 }
trapIPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap IP address"
::= { v1TrapCommunityEntry 2 }
trapCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..12))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap Community"
::= { v1TrapCommunityEntry 3 }
--
-- Remote Device upgrade
--
remDevUpgradeTable OBJECT IDENTIFIER ::= { controller 24 }
remTftpServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of tftp server"
::= { remDevUpgradeTable 1 }
remTftpFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"File name for download"
::= { remDevUpgradeTable 2 }
remFileTransferType OBJECT-TYPE
SYNTAX INTEGER {
clear-status(1),
download-GSHDSL-remote-device(11),
na(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upgrade device"
::= { remDevUpgradeTable 3 }
remUpgradeSlot OBJECT-TYPE
SYNTAX INTEGER {
slot-A(1),
slot-B(2),
slot-C(3),
slot-D(4),
slot-1(5),
slot-2(6),
slot-3(7),
slot-4(8),
slot-5(9),
slot-6(10),
slot-7(11),
slot-8(12),
slot-9(13),
slot-10(14),
slot-11(15),
slot-12(16),
na(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upgrade slot"
::= { remDevUpgradeTable 4 }
remUpgradePort OBJECT-TYPE
SYNTAX GenPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upgrade port"
::= { remDevUpgradeTable 5 }
remUpgradeCommand OBJECT-TYPE
SYNTAX INTEGER {
none(1),
upgrade(2),
upgrade-and-reset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upgrade command"
::= { remDevUpgradeTable 6 }
remUpgradePrograss OBJECT-TYPE
SYNTAX INTEGER {
na(0),
ok(1),
in-tftp-download(2),
in-send-to-card(3),
in-send-to-remote(4),
completed(5),
other-see-message(9),
card-model-error(11),
card-version-error(12),
port-unsync(13),
remote-device-error(14),
port-not-exist(15),
tftp-error(16),
fail-to-send-card(18),
check-fail(20),
check-ok(21),
rs485-loss(22),
checksum-error(23),
incorrect-file(24),
firmware-error(25),
unmatch-model(33),
other-in-send(35),
eoc-fail(36),
time-out(99),
unknown-problem(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transfer percentage"
::= { remDevUpgradeTable 7 }
remUpgradePercentage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"upgrade percentage"
::= { remDevUpgradeTable 8 }
remUpgradeMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Message of upgrade process"
::= { remDevUpgradeTable 9 }
--
-- syslogSetupTable
--
syslogSetupTable OBJECT IDENTIFIER ::= { controller 25 }
syslogSetupFunction OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SYSLOG enable/disable"
::= { syslogSetupTable 1 }
syslogServerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SYSLOG server address"
::= { syslogSetupTable 2 }
syslogServer2Address OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SYSLOG server 2 address"
::= { syslogSetupTable 3 }
--
-- inbandProtectionTable
--
-- RIKER 2013 NFS-12000476
inbandProtectionTable OBJECT IDENTIFIER ::= { controller 26 }
inbProtEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Inband protection enable/disable"
::= { inbandProtectionTable 1 }
inbProtMap OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Inband Protection Using TSI Map."
::= { inbandProtectionTable 2 }
inbProtPrimarySlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary slot number."
::= { inbandProtectionTable 3 }
inbProtPrimaryPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary port number."
::= { inbandProtectionTable 4 }
inbProtPrimaryStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary start time slot."
::= { inbandProtectionTable 5 }
inbProtSecondSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary slot number."
::= { inbandProtectionTable 6 }
inbProtSecondPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary port number."
::= { inbandProtectionTable 7 }
inbProtSecondStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary start time slot."
::= { inbandProtectionTable 8 }
inbProtSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { inbandProtectionTable 9 }
inbProtSetCommand OBJECT-TYPE
SYNTAX INTEGER {
na(0),
check-set(1),
clear(2),
force-set(3),
force-switch(4),
ok(11),
fail(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set command:
1: check and set inband map;
2: clear map;
2: force set inband map;
3: force switch"
::= { inbandProtectionTable 10 }
inbProtStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
workingPrimary(2),
workingSecondary(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inband protection status"
::= { inbandProtectionTable 11 }
--
-- radiusSetupTable
--
-- RIKER 2013 NFS-13000078
radiusSetupTable OBJECT IDENTIFIER ::= { controller 27 }
radiusServer1Enable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server1 Enable or Disable"
::= { radiusSetupTable 1 }
radiusServer1IPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server1 IP address"
::= { radiusSetupTable 2 }
radiusServer1Key OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server1 Key"
::= { radiusSetupTable 3 }
radiusServer1Port OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server1 Port"
::= { radiusSetupTable 4 }
radiusServer2Enable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server2 Enable or Disable"
::= { radiusSetupTable 5 }
radiusServer2IPaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server2 IP address"
::= { radiusSetupTable 6 }
radiusServer2Key OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) ) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server2 Key"
::= { radiusSetupTable 7 }
radiusServer2Port OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius Server2 Port"
::= { radiusSetupTable 8 }
operatorPrivilegeLevel OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Operator Privilege Level"
::= { radiusSetupTable 9 }
adminPrivilegeLevel OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Admin Privilege Level"
::= { radiusSetupTable 10 }
radiusAuthConsole OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Auth. console via Radius"
::= { radiusSetupTable 11 }
featureActivation OBJECT IDENTIFIER ::= { controller 28 }
hwInfoDisplayTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwInfoDisplayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HW info display Table"
::= { featureActivation 1 }
hwInfoDisplayEntry OBJECT-TYPE
SYNTAX HwInfoDisplayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HW info display Entry"
INDEX { hwSlotIndex }
::= { hwInfoDisplayTable 1 }
HwInfoDisplayEntry ::= SEQUENCE {
hwSlotIndex ChassisSlot,
hwCardModel GenModelType,
hwInfoJSON DisplayString
}
hwSlotIndex OBJECT-TYPE
SYNTAX ChassisSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW info slot"
::= { hwInfoDisplayEntry 1 }
hwCardModel OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW info card model"
::= { hwInfoDisplayEntry 2 }
hwInfoJSON OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HW info display in JSON format"
::= { hwInfoDisplayEntry 3 }
--============================
licenseImport OBJECT IDENTIFIER ::= { featureActivation 2 }
licenseDataImport OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..1024) ) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"License file import"
::= { licenseImport 1 }
importStatus OBJECT-TYPE
SYNTAX INTEGER {
none(1),
ok(2),
decodeFail(3),
fileFormatIncorrect(4),
noMatchCard(5),
noMatchSN(6),
unknownError(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Import status"
::= { licenseImport 2 }
--============================
faTftp OBJECT IDENTIFIER ::= { featureActivation 3 }
faServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of tftp server"
::= { faTftp 1 }
faFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"File name for upload/download"
::= { faTftp 2 }
faSlot OBJECT-TYPE
SYNTAX ChassisSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upload/download slot"
::= { faTftp 3 }
faAction OBJECT-TYPE
SYNTAX INTEGER {
none(1),
uploadHWinfo(2),
downloadLicenseFile(3),
clearStatus(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"upload/download command"
::= { faTftp 4 }
faResult OBJECT-TYPE
SYNTAX INTEGER {
na(1),
ok(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Result"
::= { faTftp 5 }
faMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Message of transfer process"
::= { faTftp 6 }
--============================
activationStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ActivationStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"activation status table"
::= { featureActivation 4 }
activationStatusEntry OBJECT-TYPE
SYNTAX ActivationStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"activation status entry"
INDEX { actSlotIndex , actItemIndex }
::= { activationStatusTable 1 }
ActivationStatusEntry ::= SEQUENCE {
actSlotIndex ChassisSlot,
actItemIndex INTEGER,
actItemName DisplayString,
actCardModel GenModelType,
actStatus DisplayString
}
actSlotIndex OBJECT-TYPE
SYNTAX ChassisSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"activation slot"
::= { activationStatusEntry 1 }
actItemIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"activation item"
::= { activationStatusEntry 2 }
actItemName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"activation name"
::= { activationStatusEntry 3 }
actCardModel OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"model of slot"
::= { activationStatusEntry 4 }
actStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"activation status"
::= { activationStatusEntry 5 }
--============================
iXC3440ActivationStatus OBJECT IDENTIFIER ::= { featureActivation 5 }
iXC3440PriCTRL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"iXC3440 is enabled for Primary controller"
::= { iXC3440ActivationStatus 1 }
iXC3440RedCTRL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
unsyncOrNotExist(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"iXC3440 is enabled for Redundant controller"
::= { iXC3440ActivationStatus 2 }
iNETLCTActivationStatus OBJECT IDENTIFIER ::= { featureActivation 6 }
iNETLCTPriCTRL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"iNET-LCT is enabled for Primary controller"
::= { iNETLCTActivationStatus 1 }
iNETLCTRedCTRL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
unsyncOrNotExist(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"iNET-LCT is enabled for Redundant controller"
::= { iNETLCTActivationStatus 2 }
--
-- SSM conversion Table , NFS-15000325, add by Bryan
--
ssmConversionTable OBJECT-TYPE
SYNTAX SEQUENCE OF SsmConvTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SSM conversion table"
::= { controller 29 }
ssmConvTableEntry OBJECT-TYPE
SYNTAX SsmConvTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SSM conversion table entry"
INDEX { ssmQualityLevel }
::= { ssmConversionTable 1 }
SsmConvTableEntry ::= SEQUENCE {
ssmQualityLevel INTEGER,
ssmDS1-SSM INTEGER,
ssmE1-SSM INTEGER
}
ssmQualityLevel OBJECT-TYPE
SYNTAX INTEGER {
levelPRS(1),
levelSTU(2),
levelST2(3),
-- levelTNC(4),
-- levelST3E(5),
levelST3(4),
levelSMC(5),
levelST4(6),
levelDUS(7),
levelRES(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Quality Level"
::= { ssmConvTableEntry 1 }
ssmDS1-SSM OBJECT-TYPE
SYNTAX INTEGER {
ssm000010(1),
ssm000100(2),
ssm000110(3),
ssm111100(4),
ssm111110(5),
ssm001000(6),
ssm010001(7),
ssm010100(8),
ssm011000(9),
ssm100000(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS1 SSM value"
::= { ssmConvTableEntry 2 }
ssmE1-SSM OBJECT-TYPE
SYNTAX INTEGER {
ssm0000(1),
ssm0001(2),
ssm0010(3),
ssm0011(4),
ssm0100(5),
ssm0101(6),
ssm0110(7),
ssm0111(8),
ssm1000(9),
ssm1001(10),
ssm1010(11),
ssm1011(12),
ssm1100(13),
ssm1101(14),
ssm1110(15),
ssm1111(16)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 SSM value
0000 Internal
1111 Not Used"
::= { ssmConvTableEntry 3 }
--
-- external alarm table
--
externalAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF ExternalAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SSM conversion table"
::= { controller 30 }
externalAlarmEntry OBJECT-TYPE
SYNTAX ExternalAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SSM conversion table entry"
INDEX { extAlarmIndex }
::= { externalAlarmTable 1 }
ExternalAlarmEntry ::= SEQUENCE {
extAlarmIndex INTEGER,
extAlarmSeverity AlarmSeverity,
extAlarmMessage DisplayString
}
extAlarmIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"external alarm index"
::= { externalAlarmEntry 1 }
extAlarmSeverity OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Severity"
::= { externalAlarmEntry 2 }
extAlarmMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Message"
::= { externalAlarmEntry 3 }
--
-- new timing source (CCB)
--
ccbTimingSource OBJECT IDENTIFIER ::= { controller 31 }
ccbClockMode OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
ssm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Clock Mode"
::= { ccbTimingSource 1 }
ccbCurrentClock OBJECT-TYPE
SYNTAX INTEGER {
first(1),
second(2),
third(3),
internal(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current clock source"
::= { ccbTimingSource 2 }
ccbClockHoldOverEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
notSupport(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock Hold-over Mode"
::= { ccbTimingSource 3 }
ccbNormalClockRecover OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
automatic(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Normal Clock Recover Mode"
::= { ccbTimingSource 4 }
ccbStaticInternalSSM OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"static internal ssm message"
::= { ccbTimingSource 5 }
ccbStaticExternalSSM OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"static external ssm message"
::= { ccbTimingSource 6 }
ccbStaticLineSSM OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"static line ssm message"
::= { ccbTimingSource 7 }
ccbHoldOverState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
holdOver(2),
notSupport(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clock hold-over state"
::= { ccbTimingSource 8 }
ccbFramePulsePeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frame Pulse Period: Hz"
::= { ccbTimingSource 9 }
ccbSSMHoldTime OBJECT-TYPE
SYNTAX INTEGER (0..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SSM hold time"
::= { ccbTimingSource 10 }
ccbDpllClockState OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
normal-m(2),
normal-s(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clock dpll state"
::= { ccbTimingSource 13 }
-- external clock input
-- CCB clock source setup
ccbClockSourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcbClockSourceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"CCB clock source"
::= { ccbTimingSource 12 }
ccbClockSourceEntry OBJECT-TYPE
SYNTAX CcbClockSourceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ccb clock source"
INDEX { ccbClockIndex }
::= { ccbClockSourceTable 1 }
CcbClockSourceEntry ::= SEQUENCE {
ccbClockIndex INTEGER,
ccbClockSource INTEGER,
ccbClockPort INTEGER,
ccbClockState INTEGER
}
ccbClockIndex OBJECT-TYPE
SYNTAX INTEGER (1..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"clock index"
::= { ccbClockSourceEntry 1 }
ccbClockSource OBJECT-TYPE
SYNTAX INTEGER {
none(0),
internal(1),
-- external(2),
slotA(3),
slotB(4),
slotC(5),
slotD(6),
slot1(7),
slot2(8),
slot3(9),
slot4(10),
slot5(11),
slot6(12),
slot7(13),
slot8(14),
slot9(15),
slot10(16),
slot11(17),
slot12(18),
acr1(19),
acr2(20),
acr3(21),
acr4(22),
ctrl1eth1(23),
ctrl1eth2(24),
ctrl2eth1(31),
ctrl2eth2(32)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clock source slot"
::= { ccbClockSourceEntry 2 }
ccbClockPort OBJECT-TYPE
SYNTAX INTEGER {
none(0),
port1(1),
port2(2),
port3(3),
port4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clock source port"
::= { ccbClockSourceEntry 3 }
ccbClockState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
lossOrNotStable(2),
signalDetected(3),
rxSSM0000(10),
rxSSM0001(11),
rxSSM0010(12),
rxSSM0011(13),
rxSSM0100(14),
rxSSM0101(15),
rxSSM0110(16),
rxSSM0111(17),
rxSSM1000(18),
rxSSM1001(19),
rxSSM1010(20),
rxSSM1011(21),
rxSSM1100(22),
rxSSM1101(23),
rxSSM1110(24),
rxSSM1111(25)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"clock state"
::= { ccbClockSourceEntry 4 }
--
-- console/telnet user list and password change
--
consoleTelnetUser OBJECT IDENTIFIER ::= { controller 32 }
userListTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"user list table"
::= { consoleTelnetUser 1 }
userListEntry OBJECT-TYPE
SYNTAX UserListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"user list entry"
INDEX { userIndex }
::= { userListTable 1 }
UserListEntry ::= SEQUENCE {
userIndex INTEGER,
userName DisplayString,
userLevel INTEGER
}
userIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"user index"
::= { userListEntry 1 }
userName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"user name"
::= { userListEntry 2 }
userLevel OBJECT-TYPE
SYNTAX INTEGER {
operator(1),
admin(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"user level"
::= { userListEntry 3 }
userPasswordChange OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (10..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"password change by NMS"
::= { consoleTelnetUser 2 }
userPwChangeResponse OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"password change response:
USERNAME password changed!
Format not correct!
Password too long!
User name not exist!"
::= { consoleTelnetUser 3 }
userLoginTimeout OBJECT-TYPE
SYNTAX INTEGER (60..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"timeout in seconds"
::= { consoleTelnetUser 4 }
userLoginAttempts OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"login attempts"
::= { consoleTelnetUser 5 }
lockoutDuration OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"log fail (lockout) recovery timer in minutes, 0=infinite"
::= { consoleTelnetUser 6 }
unlockLogOn OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..28))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Console/telnet/SSH unlock (for user login failure attempts)"
::= { consoleTelnetUser 7 }
ethernetTable OBJECT IDENTIFIER ::= { controller 33 }
ethernetCopperSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetCopperSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Copper Set table"
::= { ethernetTable 1 }
ethernetCopperSetEntry OBJECT-TYPE
SYNTAX EthernetCopperSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Copper Setup entry"
INDEX { ethernetCopperIndex }
::= { ethernetCopperSetTable 1 }
EthernetCopperSetEntry ::= SEQUENCE {
ethernetCopperIndex INTEGER,
ethernetCopperName DisplayString,
ethernetCopperState INTEGER,
ethernetCopperSpeed INTEGER
}
ethernetCopperIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CopperSet index"
::= { ethernetCopperSetEntry 1 }
ethernetCopperName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CopperSet name"
::= { ethernetCopperSetEntry 2 }
ethernetCopperState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CopperSet state"
::= { ethernetCopperSetEntry 3 }
ethernetCopperSpeed OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
s1000full(2),
s1000half(3),
s100full(4),
s100half(5),
s10full(6),
s10half(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CopperSet speed"
::= { ethernetCopperSetEntry 4 }
ethernetOpticalSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetOpticalSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Optical Set table"
::= { ethernetTable 2 }
ethernetOpticalSetEntry OBJECT-TYPE
SYNTAX EthernetOpticalSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Fiber Setup entry"
INDEX { ethernetOpticalIndex }
::= { ethernetOpticalSetTable 1 }
EthernetOpticalSetEntry ::= SEQUENCE {
ethernetOpticalIndex INTEGER,
ethernetOpticalName DisplayString,
ethernetOpticalState INTEGER,
ethernetOpticalSpeed INTEGER,
ethernetOpticalUnidirectional INTEGER
}
ethernetOpticalIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical index"
::= { ethernetOpticalSetEntry 1 }
ethernetOpticalName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical name"
::= { ethernetOpticalSetEntry 2 }
ethernetOpticalState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical state"
::= { ethernetOpticalSetEntry 3 }
ethernetOpticalSpeed OBJECT-TYPE
SYNTAX INTEGER {
s1000(1),
s100(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical speed"
::= { ethernetOpticalSetEntry 4 }
ethernetOpticalUnidirectional OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unidirectional mode"
::= { ethernetOpticalSetEntry 5 }
ethernetStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Optical Set table"
::= { ethernetTable 3 }
ethernetStatusEntry OBJECT-TYPE
SYNTAX EthernetStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Status entry"
INDEX { ethernetStatusIndex }
::= { ethernetStatusTable 1 }
EthernetStatusEntry ::= SEQUENCE {
ethernetStatusIndex INTEGER,
ethernetStatusName DisplayString,
ethernetStatusMode INTEGER,
ethernetStatusLink INTEGER,
ethernetStatusSpeed INTEGER,
ethernetStatusUnidirectional INTEGER
}
ethernetStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical index"
::= { ethernetStatusEntry 1 }
ethernetStatusName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical name"
::= { ethernetStatusEntry 2 }
ethernetStatusMode OBJECT-TYPE
SYNTAX INTEGER {
copper(1),
optical(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical state"
::= { ethernetStatusEntry 3 }
ethernetStatusLink OBJECT-TYPE
SYNTAX INTEGER {
linkup(1),
linkdown(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical state"
::= { ethernetStatusEntry 4 }
ethernetStatusSpeed OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
s1000full(2),
s1000half(3),
s100full(4),
s100half(5),
s10full(6),
s10half(7),
none(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical speed"
::= { ethernetStatusEntry 5 }
ethernetStatusUnidirectional OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unidirectional state"
::= { ethernetStatusEntry 6 }
ethernetCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthernetCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ethernet Count table"
::= { ethernetTable 4 }
ethernetCountEntry OBJECT-TYPE
SYNTAX EthernetCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Count entry"
INDEX { ethernetCountIndex }
::= { ethernetCountTable 1 }
EthernetCountEntry ::= SEQUENCE {
ethernetCountIndex INTEGER,
ethernetCountName DisplayString,
ethernetTxGoodPkt INTEGER,
ethernetTxMultiPkt INTEGER,
ethernetTxBroadcastPkt INTEGER,
ethernetTxLength INTEGER,
ethernetRxGoodPkt INTEGER,
ethernetRxFCSerror INTEGER,
ethernetRxBadCount INTEGER,
ethernetRxLength INTEGER
}
ethernetCountIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ethernet index"
::= { ethernetCountEntry 1 }
ethernetCountName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ethernet Count name"
::= { ethernetCountEntry 2 }
ethernetTxGoodPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 3 }
ethernetTxMultiPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 4 }
ethernetTxBroadcastPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 5 }
ethernetTxLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 6 }
ethernetRxGoodPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 7 }
ethernetRxFCSerror OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 8 }
ethernetRxBadCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 9 }
ethernetRxLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count ethernetTxGoodPkt"
::= { ethernetCountEntry 10 }
ctrl2CopperSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ctrl2CopperSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Copper Set table"
::= { ethernetTable 5 }
ctrl2CopperSetEntry OBJECT-TYPE
SYNTAX Ctrl2CopperSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Copper Setup entry"
INDEX { ctrl2CopperIndex }
::= { ctrl2CopperSetTable 1 }
Ctrl2CopperSetEntry ::= SEQUENCE {
ctrl2CopperIndex INTEGER,
ctrl2CopperName DisplayString,
ctrl2CopperState INTEGER,
ctrl2CopperSpeed INTEGER
}
ctrl2CopperIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CopperSet index"
::= { ctrl2CopperSetEntry 1 }
ctrl2CopperName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CopperSet name"
::= { ctrl2CopperSetEntry 2 }
ctrl2CopperState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CopperSet state"
::= { ctrl2CopperSetEntry 3 }
ctrl2CopperSpeed OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
s1000full(2),
s1000half(3),
s100full(4),
s100half(5),
s10full(6),
s10half(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CopperSet speed"
::= { ctrl2CopperSetEntry 4 }
ctrl2OpticalSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ctrl2OpticalSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Optical Set table"
::= { ethernetTable 6 }
ctrl2OpticalSetEntry OBJECT-TYPE
SYNTAX Ctrl2OpticalSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet Fiber Setup entry"
INDEX { ctrl2OpticalIndex }
::= { ctrl2OpticalSetTable 1 }
Ctrl2OpticalSetEntry ::= SEQUENCE {
ctrl2OpticalIndex INTEGER,
ctrl2OpticalName DisplayString,
ctrl2OpticalState INTEGER,
ctrl2OpticalSpeed INTEGER,
ctrl2OpticalUnidirectional INTEGER
}
ctrl2OpticalIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical index"
::= { ctrl2OpticalSetEntry 1 }
ctrl2OpticalName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical name"
::= { ctrl2OpticalSetEntry 2 }
ctrl2OpticalState OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical state"
::= { ctrl2OpticalSetEntry 3 }
ctrl2OpticalSpeed OBJECT-TYPE
SYNTAX INTEGER {
s1000(1),
s100(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical speed"
::= { ctrl2OpticalSetEntry 4 }
ctrl2OpticalUnidirectional OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unidirectional mode"
::= { ctrl2OpticalSetEntry 5 }
--
-- PseudWire Setup Table
--
pwCtrlSetupTable OBJECT IDENTIFIER ::= { controller 34 }
pwSourceSetupTable OBJECT IDENTIFIER ::= { pwCtrlSetupTable 1 }
pwPriSourceIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire Source IP"
::= { pwSourceSetupTable 1 }
pwPriSourceNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP netmask"
::= { pwSourceSetupTable 2 }
pwPriSourceGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP Gateway"
::= { pwSourceSetupTable 3 }
pwPriSourceMac OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire source mac address"
::= { pwSourceSetupTable 4 }
pwSecSourceIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire 2nd Source IP"
::= { pwSourceSetupTable 5 }
pwSecSourceNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire 2nd IP netmask"
::= { pwSourceSetupTable 6 }
pwSecSourceGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire 2nd IP Gateway"
::= { pwSourceSetupTable 7 }
pwSecSourceMac OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire 2nd source mac address"
::= { pwSourceSetupTable 8 }
pwActiveTimer OBJECT-TYPE
SYNTAX INTEGER (1..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire active timer 1~99"
::= { pwSourceSetupTable 17 }
pwRemoteLoss OBJECT-TYPE
SYNTAX INTEGER{
continue(1),
stop(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire source mac address"
::= { pwSourceSetupTable 18 }
pwSVlanTPID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire svlan tpid"
::= { pwSourceSetupTable 19 }
--
-- PseudWire Alarm Setup Table
--
pwAlarmSetupTable OBJECT IDENTIFIER ::= { pwCtrlSetupTable 3 }
pwArpLost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"arp-bundle alarm severity type"
::= { pwAlarmSetupTable 1 }
pwRxLost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rx lost alarm severity type"
::= { pwAlarmSetupTable 2 }
pwLostOfBundle OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"lost of bundle alarm "
::= { pwAlarmSetupTable 3 }
pwUnderRun OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"underrun alarm severity type"
::= { pwAlarmSetupTable 4 }
pwOverRun OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"overrun alarm severity type"
::= { pwAlarmSetupTable 5 }
pwLBitAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LBit alarm severity type"
::= { pwAlarmSetupTable 6 }
pwRBitAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RBit alarm severity type"
::= { pwAlarmSetupTable 7 }
pwIPConflictAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Conflictalarm severity type"
::= { pwAlarmSetupTable 8 }
ctrl1ETH1ELECAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 1 Eth 1 electrical Link down alarm"
::= { pwAlarmSetupTable 9 }
ctrl1ETH2ELECAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 1 Eth 2 electrical Link down alarm"
::= { pwAlarmSetupTable 10 }
ctrl1ETH1OPTIAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 1 Eth 1 optical Link down alarm"
::= { pwAlarmSetupTable 11 }
ctrl1ETH2OPTIAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 1 Eth 2 optical Link down alarm"
::= { pwAlarmSetupTable 12 }
ctrl2ETH1ELECAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 2 Eth 1 electrical Link down alarm"
::= { pwAlarmSetupTable 15 }
ctrl2ETH2ELECAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 2 Eth 2 electrical Link down alarm"
::= { pwAlarmSetupTable 16 }
ctrl2ETH1OPTIAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 2 Eth 1 optical Link down alarm"
::= { pwAlarmSetupTable 17 }
ctrl2ETH2OPTIAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"controller 2 Eth 2 optical Link down alarm"
::= { pwAlarmSetupTable 18 }
eth1LOOPAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Eth 1 looping alarm"
::= { pwAlarmSetupTable 13 }
eth2LOOPAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Eth 2 looping alarm"
::= { pwAlarmSetupTable 14 }
--
-- PseudWire Clock Setup Table
--
pwClockSetupTable OBJECT IDENTIFIER ::= { pwCtrlSetupTable 4 }
pwACRConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWACRConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw ACR Config Table."
::= { pwClockSetupTable 1 }
pwACRConfigEntry OBJECT-TYPE
SYNTAX PWACRConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Pw ACR Config Entry"
INDEX { pwACRIndex }
::= { pwACRConfigTable 1 }
PWACRConfigEntry ::= SEQUENCE {
pwACRIndex INTEGER,
pwACRPortID INTEGER,
pwACREnable INTEGER,
pwACRStatus INTEGER
}
pwACRIndex OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { pwACRConfigEntry 1 }
pwACRPortID OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { pwACRConfigEntry 2 }
pwACREnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { pwACRConfigEntry 3 }
pwACRStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
acquisition(2),
tracking1(3),
tracking2(4),
tracking3(5),
tracking4(6),
tracking5(7),
none(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { pwACRConfigEntry 4 }
timeStampUploadTable OBJECT IDENTIFIER ::= { pwClockSetupTable 2 }
pwTftpServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload TFTP server IP."
::= { timeStampUploadTable 1 }
pwAcrNum OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload ACR Number."
::= { timeStampUploadTable 2 }
pwEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload Enable/Disable."
::= { timeStampUploadTable 3 }
--
-- PseudWire Mode Setup Table
--
pwProtectModeSetupTable OBJECT IDENTIFIER ::= { pwCtrlSetupTable 5 }
pwModeSelect OBJECT-TYPE
SYNTAX INTEGER {
-- mode0(1),
mode1(2),
mode2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw protect mode select"
::= { pwProtectModeSetupTable 1 }
-- pwModeAction OBJECT-TYPE
-- SYNTAX INTEGER {
-- nonrevertible(1),
-- revertible(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "pw protect mode action"
-- ::= { pwProtectModeSetupTable 2 }
pwCascadePort OBJECT-TYPE
SYNTAX INTEGER {
eth1LinkUp(1),
eth2LinkUp(2),
eth1LinkDown(3),
eth2LinkDown(4),
na(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw protect cascade port"
::= { pwProtectModeSetupTable 3 }
pwCascadeChannel OBJECT-TYPE
SYNTAX INTEGER {
notReady(1),
ready(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw protect cascade channel"
::= { pwProtectModeSetupTable 4 }
--
-- New PseudWire Bundle Setup Table
--
-- primary
pwProtectBundleSetup OBJECT IDENTIFIER ::= { pwCtrlSetupTable 6 }
pwPriPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle port 1~64"
::= { pwProtectBundleSetup 1 }
pwPriFormat OBJECT-TYPE
SYNTAX INTEGER{
cesopsn(2),
satop(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle format"
::= { pwProtectBundleSetup 2 }
pwPriType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
-- ipwithRTP(3),
-- cesoEthwithRTP(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle Type"
::= { pwProtectBundleSetup 3 }
pwPriTos OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle TOS"
::= { pwProtectBundleSetup 4 }
pwPriUdpEcid OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle udp/ecid"
::= { pwProtectBundleSetup 5 }
pwPriFrame OBJECT-TYPE
SYNTAX INTEGER {
nonCAS(1),
e1CAS(3),
t1CAS(4),
e1unframe(5),
t1unframe(6),
t1unframe192(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle frame item"
::= { pwProtectBundleSetup 6 }
pwPriDestIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle ip item"
::= { pwProtectBundleSetup 7 }
pwPriStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Stratum Setup"
::= { pwProtectBundleSetup 8 }
pwPriNumofTimeslot OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw number of timeslot"
::= { pwProtectBundleSetup 9 }
pwPriNumofFrame OBJECT-TYPE
SYNTAX INTEGER (1..1500)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw number of Frame"
::= { pwProtectBundleSetup 10 }
pwPriJitterDelay OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw jitter delay"
::= { pwProtectBundleSetup 11 }
pwPriJitterSize OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw jitter size"
::= { pwProtectBundleSetup 12 }
pwPriVlanSetup OBJECT-TYPE
SYNTAX INTEGER{
off(1),
cvlan(2),
svlan(3),
qinq(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw vlan"
::= { pwProtectBundleSetup 13 }
pwPriCVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { pwProtectBundleSetup 14 }
pwPriCVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { pwProtectBundleSetup 15 }
pwPriSVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { pwProtectBundleSetup 16 }
pwPriSVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { pwProtectBundleSetup 17 }
-- Secondary
pwSecFormat OBJECT-TYPE
SYNTAX INTEGER{
cesopsn(2),
satop(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle format"
::= { pwProtectBundleSetup 18 }
pwSecType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
-- ipwithRTP(3),
-- cesoEthwithRTP(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle Type"
::= { pwProtectBundleSetup 19 }
pwSecTos OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle TOS"
::= { pwProtectBundleSetup 20 }
pwSecUdpEcid OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle udp/ecid"
::= { pwProtectBundleSetup 21 }
pwSecFrame OBJECT-TYPE
SYNTAX INTEGER {
nonCAS(1),
e1CAS(3),
t1CAS(4),
e1unframe(5),
t1unframe(6),
t1unframe192(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle frame item"
::= { pwProtectBundleSetup 22 }
pwSecDestIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle ip item"
::= { pwProtectBundleSetup 23 }
pwSecStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Stratum Setup"
::= { pwProtectBundleSetup 24 }
pwSecNumofTimeslot OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw number of timeslot"
::= { pwProtectBundleSetup 25 }
pwSecNumofFrame OBJECT-TYPE
SYNTAX INTEGER (1..1500)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw number of Frame"
::= { pwProtectBundleSetup 26 }
pwSecJitterDelay OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw jitter delay"
::= { pwProtectBundleSetup 27 }
pwSecJitterSize OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw jitter size"
::= { pwProtectBundleSetup 28 }
-- pwSecVlanSetup OBJECT-TYPE
-- SYNTAX INTEGER{
-- off(1),
-- cvlan(2),
-- svlan(3)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "pw vlan"
-- ::= { pwProtectBundleSetup 29 }
pwSecCVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { pwProtectBundleSetup 30 }
pwSecCVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { pwProtectBundleSetup 31 }
pwSecSVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { pwProtectBundleSetup 32 }
pwSecSVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { pwProtectBundleSetup 33 }
pwProtectAction OBJECT-TYPE
SYNTAX INTEGER {
activateBundle(1),
deleteBundle(2),
deleteAll(3),
-- activeAll(4),
changeBundle(5),
stopBundleTx(6),
addPriPath(7),
add2ndPath(8),
delPriPath(9),
del2ndPath(10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle action"
::= { pwProtectBundleSetup 34}
pwProtectConfirm OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"pw Confirm Setup"
::= { pwProtectBundleSetup 35}
pwProtectCfgStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle cfg status"
::= { pwProtectBundleSetup 36 }
--
-- New PseudWire Bundle Setup Table
--
pwPerfClearSetup OBJECT IDENTIFIER ::= { pwCtrlSetupTable 7 }
pwPerfStatistClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo perf clear"
::= { pwPerfClearSetup 1 }
pwBundleStatistClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo bundle statistics perf clear"
::= { pwPerfClearSetup 2 }
pwArrivalTimeClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo arrival time statistics clear"
::= { pwPerfClearSetup 3 }
pwRoundTripStatistClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo bundle round trip statistics perf clear"
::= { pwPerfClearSetup 4 }
pwProtectStatistClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo bundle Protect statistics perf clear"
::= { pwPerfClearSetup 5 }
dpllStickyClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Dpll sticky clear"
::= { pwPerfClearSetup 6 }
acrStatusClear OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"acr status clear"
::= { pwPerfClearSetup 7 }
pwPerPerfStatistClear OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"per Pseudo perf clear"
::= { pwPerfClearSetup 8 }
--
-- PseudWire Round Trip Delay Table
--
pwRoundTripDelay OBJECT IDENTIFIER ::= { pwCtrlSetupTable 8 }
pwRoundTripBid OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo round trip delay bid 0~64"
::= { pwRoundTripDelay 1 }
pwRoundTripAction OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo bundle round trip action"
::= { pwRoundTripDelay 2 }
--
-- PseudWire Jitter Buffer Recenter Table
--
pwJitterBufRecenter OBJECT IDENTIFIER ::= { pwCtrlSetupTable 9 }
pwJitterBufBid OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo jitter buf bid 0~64"
::= { pwJitterBufRecenter 1 }
pwJitterBufAction OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Pseudo jitter buf action"
::= { pwJitterBufRecenter 2 }
--
-- PseudWire Status Table
--
pwCtrlStatusTable OBJECT IDENTIFIER ::= { controller 35 }
pwSourceStatusTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 1 }
pwPriSrcIPInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Source IP"
::= { pwSourceStatusTable 1 }
pwPriSubnetMaskInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP netmask"
::= { pwSourceStatusTable 2 }
pwPriGatewayIPInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP Gateway"
::= { pwSourceStatusTable 3 }
pwPriMacAddrInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire source mac address"
::= { pwSourceStatusTable 4 }
pwSecSrcIPInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Source IP"
::= { pwSourceStatusTable 5 }
pwSecSubnetMaskInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP netmask"
::= { pwSourceStatusTable 6 }
pwSecGatewayIPInfo OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire IP Gateway"
::= { pwSourceStatusTable 7 }
pwSecMacAddrInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire source mac address"
::= { pwSourceStatusTable 8 }
pwActiveTimerInfo OBJECT-TYPE
SYNTAX INTEGER (1..99)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire active timer 1~99"
::= { pwSourceStatusTable 17 }
pwRemoteLossInfo OBJECT-TYPE
SYNTAX INTEGER{
continue(1),
stop(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire source mac address"
::= { pwSourceStatusTable 18 }
pwSVlanTPIDInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire svlan tpid"
::= { pwSourceStatusTable 19 }
--
-- PseudWire Status Table
--
pwBundleStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWBundleStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw status table"
::= { pwCtrlStatusTable 2 }
pwBundleStatusEntry OBJECT-TYPE
SYNTAX PWBundleStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw status entry"
INDEX { pwStatusIndex }
::= { pwBundleStatusTable 1 }
PWBundleStatusEntry ::= SEQUENCE {
pwStatusIndex INTEGER,
pwStatusPort INTEGER,
pwStatusFormat INTEGER,
pwStatusType INTEGER,
pwStatusTos INTEGER,
pwStatusUdpEcid INTEGER,
pwStatusFrame INTEGER,
pwStatusPriDestIP DisplayString,
pwStatusStratum INTEGER,
pwStatusNumofTimeslot INTEGER,
pwStatusNumofFrame INTEGER,
pwStatusJitterDelay INTEGER,
pwStatusJitterSize INTEGER,
pwStatusVlanSetup INTEGER,
pwStatusCVlanID INTEGER,
pwStatusCVlanPriority INTEGER,
pwStatusSVlanID INTEGER,
pwStatusSVlanPriority INTEGER,
pwStatusAction INTEGER,
pwSecStatusPort INTEGER,
pwSecStatusFormat INTEGER,
pwSecStatusType INTEGER,
pwSecStatusTos INTEGER,
pwSecStatusUdpEcid INTEGER,
pwSecStatusFrame INTEGER,
pwSecStatusPriDestIP DisplayString,
pwSecStatusStratum INTEGER,
pwSecStatusNumofTimeslot INTEGER,
pwSecStatusNumofFrame INTEGER,
pwSecStatusJitterDelay INTEGER,
pwSecStatusJitterSize INTEGER,
pwSecStatusVlanSetup INTEGER,
pwSecStatusCVlanID INTEGER,
pwSecStatusCVlanPriority INTEGER,
pwSecStatusSVlanID INTEGER,
pwSecStatusSVlanPriority INTEGER,
pwSecStatusAction INTEGER
}
pwStatusIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Index 1~64"
::= { pwBundleStatusEntry 1 }
pwStatusPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle port 1~64"
::= { pwBundleStatusEntry 2 }
pwStatusFormat OBJECT-TYPE
SYNTAX INTEGER{
cesopsn(2),
satop(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle format"
::= { pwBundleStatusEntry 3 }
pwStatusType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
-- ipwithRTP(3),
-- cesoEthwithRTP(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle Type"
::= { pwBundleStatusEntry 4 }
pwStatusTos OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle TOS"
::= { pwBundleStatusEntry 5 }
pwStatusUdpEcid OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle udp/ecid"
::= { pwBundleStatusEntry 6 }
pwStatusFrame OBJECT-TYPE
SYNTAX INTEGER {
nonCAS(1),
e1CAS(3),
t1CAS(4),
e1unframe(5),
t1unframe(6),
t1unframe192(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle cas item"
::= { pwBundleStatusEntry 7 }
pwStatusPriDestIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle cas item"
::= { pwBundleStatusEntry 8 }
pwStatusStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stratum Setup"
::= { pwBundleStatusEntry 12 }
pwStatusNumofTimeslot OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw number of timeslot"
::= { pwBundleStatusEntry 13 }
pwStatusNumofFrame OBJECT-TYPE
SYNTAX INTEGER (1..1500)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw number of Frame"
::= { pwBundleStatusEntry 14 }
pwStatusJitterDelay OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw jitter delay"
::= { pwBundleStatusEntry 15 }
pwStatusJitterSize OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw jitter delay"
::= { pwBundleStatusEntry 16 }
pwStatusVlanSetup OBJECT-TYPE
SYNTAX INTEGER{
off(1),
cvlan(2),
svlan(3),
qinq(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw vlan"
::= { pwBundleStatusEntry 17 }
pwStatusCVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { pwBundleStatusEntry 18 }
pwStatusCVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { pwBundleStatusEntry 19 }
pwStatusSVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { pwBundleStatusEntry 20 }
pwStatusSVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { pwBundleStatusEntry 21 }
pwStatusAction OBJECT-TYPE
SYNTAX INTEGER {
active(1),
-- deleteBundle(2),
-- deleteAll(3),
-- activeAll(4),
-- changeBundle(5)
standby(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle action"
::= { pwBundleStatusEntry 22}
pwSecStatusPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pseudo Wire bundle port 1~64"
::= { pwBundleStatusEntry 23 }
pwSecStatusFormat OBJECT-TYPE
SYNTAX INTEGER{
cesopsn(2),
satop(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle format"
::= { pwBundleStatusEntry 24 }
pwSecStatusType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
-- ipwithRTP(3),
-- cesoEthwithRTP(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle Type"
::= { pwBundleStatusEntry 25 }
pwSecStatusTos OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle TOS"
::= { pwBundleStatusEntry 26 }
pwSecStatusUdpEcid OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle udp/ecid"
::= { pwBundleStatusEntry 27 }
pwSecStatusFrame OBJECT-TYPE
SYNTAX INTEGER {
nonCAS(1),
e1CAS(3),
t1CAS(4),
e1unframe(5),
t1unframe(6),
t1unframe192(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle cas item"
::= { pwBundleStatusEntry 28 }
pwSecStatusPriDestIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pseudo Wire bundle cas item"
::= { pwBundleStatusEntry 29 }
pwSecStatusStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Stratum Setup"
::= { pwBundleStatusEntry 30 }
pwSecStatusNumofTimeslot OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw number of timeslot"
::= { pwBundleStatusEntry 31 }
pwSecStatusNumofFrame OBJECT-TYPE
SYNTAX INTEGER (1..1500)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secpw number of Frame"
::= { pwBundleStatusEntry 32 }
pwSecStatusJitterDelay OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw jitter delay"
::= { pwBundleStatusEntry 33 }
pwSecStatusJitterSize OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec pw jitter delay"
::= { pwBundleStatusEntry 34 }
pwSecStatusVlanSetup OBJECT-TYPE
SYNTAX INTEGER{
off(1),
cvlan(2),
svlan(3),
qinq(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec pw vlan"
::= { pwBundleStatusEntry 35 }
pwSecStatusCVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec customer VLAN ID"
::= { pwBundleStatusEntry 36 }
pwSecStatusCVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec customer VLAN Priority"
::= { pwBundleStatusEntry 37 }
pwSecStatusSVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec provider VLAN ID"
::= { pwBundleStatusEntry 38 }
pwSecStatusSVlanPriority OBJECT-TYPE
SYNTAX INTEGER {
p0(1),
p1(2),
p2(3),
p3(4),
p4(5),
p5(6),
p6(7),
p7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec provider VLAN Priority"
::= { pwBundleStatusEntry 39 }
pwSecStatusAction OBJECT-TYPE
SYNTAX INTEGER {
active(1),
standby(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"sec bundle action"
::= { pwBundleStatusEntry 40}
--
-- PseudWire Statics Table
--
pwBundleStaticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWBundleStaticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw statics table"
::= { pwCtrlStatusTable 3 }
pwBundleStaticsEntry OBJECT-TYPE
SYNTAX PWBundleStaticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw statics entry"
INDEX { pwStaticsIndex }
::= { pwBundleStaticsTable 1 }
PWBundleStaticsEntry ::= SEQUENCE {
pwStaticsIndex INTEGER,
pwStaticsPort INTEGER,
pwJitBufUnderRun INTEGER,
pwJitBufOverRun INTEGER,
pwJitBufMin INTEGER,
pwJitBufMax INTEGER,
pwJitBufDepth INTEGER,
pwLBitCount INTEGER,
pwRBitCount INTEGER,
pwTxGoodCount INTEGER,
pwRxGoodCount INTEGER,
pwRxLostCount INTEGER,
pwLink INTEGER,
pwSizeError INTEGER,
pwRxAISAlm INTEGER,
pwPath INTEGER,
pwMisOrderCount INTEGER,
pwRxDuplicateCount INTEGER
}
pwStaticsIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Index 1~64"
::= { pwBundleStaticsEntry 1 }
pwStaticsPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle port 1~64"
::= { pwBundleStaticsEntry 2 }
pwJitBufUnderRun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter uv"
::= { pwBundleStaticsEntry 3 }
pwJitBufOverRun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter ov"
::= { pwBundleStaticsEntry 4 }
pwJitBufMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter min"
::= { pwBundleStaticsEntry 5 }
pwJitBufMax OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter max"
::= { pwBundleStaticsEntry 6 }
pwJitBufDepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter depth"
::= { pwBundleStaticsEntry 7 }
pwLBitCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw l-bit error"
::= { pwBundleStaticsEntry 8 }
pwRBitCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw r-bit error"
::= { pwBundleStaticsEntry 9 }
pwTxGoodCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw tx good pkt"
::= { pwBundleStaticsEntry 10 }
pwRxGoodCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx good pkt"
::= { pwBundleStaticsEntry 11 }
pwRxLostCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx lost count"
::= { pwBundleStaticsEntry 12 }
pwLink OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw link status"
::= { pwBundleStaticsEntry 13 }
pwSizeError OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2),
cas(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw size error"
::= { pwBundleStaticsEntry 14 }
pwRxAISAlm OBJECT-TYPE
SYNTAX INTEGER{
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx ais alm"
::= { pwBundleStaticsEntry 15 }
pwPath OBJECT-TYPE
SYNTAX INTEGER{
pri(1),
sec(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw path"
::= { pwBundleStaticsEntry 16 }
pwMisOrderCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw miss-order count"
::= { pwBundleStaticsEntry 17 }
pwRxDuplicateCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx duplicate count"
::= { pwBundleStaticsEntry 18 }
--
-- PseudWire Delay Info Table
--
pwBundleDelayInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw delay info table"
::= { pwCtrlStatusTable 4 }
pwBundleDelayInfoEntry OBJECT-TYPE
SYNTAX PWBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw Delay Info entry"
INDEX { pwInfoIndex }
::= { pwBundleDelayInfoTable 1 }
PWBundleDelayInfoEntry ::= SEQUENCE {
pwInfoIndex INTEGER,
pwInfoPort INTEGER,
pwCellNum INTEGER,
pwJitterDelaySt INTEGER,
pwJitterSizeSt INTEGER,
pwPropDelay DisplayString,
pwPktSize DisplayString,
pwOverHead DisplayString,
pwEthernetBW DisplayString,
pwTotalBW DisplayString
}
pwInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Index 1~64"
::= { pwBundleDelayInfoEntry 1 }
pwInfoPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle port 1~64"
::= { pwBundleDelayInfoEntry 2 }
pwCellNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw cell number"
::= { pwBundleDelayInfoEntry 3 }
pwJitterDelaySt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter delay"
::= { pwBundleDelayInfoEntry 4 }
pwJitterSizeSt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter size"
::= { pwBundleDelayInfoEntry 5 }
pwPropDelay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter prop delay"
::= { pwBundleDelayInfoEntry 6 }
pwPktSize OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw pkt size"
::= { pwBundleDelayInfoEntry 7 }
pwOverHead OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw over head"
::= { pwBundleDelayInfoEntry 8 }
pwEthernetBW OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw ethernet bw"
::= { pwBundleDelayInfoEntry 9 }
pwTotalBW OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw total bw"
::= { pwBundleDelayInfoEntry 10 }
pwAlarmStatusTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 5 }
pwArpLostStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"arp-bundle alarm severity type"
::= { pwAlarmStatusTable 1 }
pwRxLostStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"rx lost alarm severity type"
::= { pwAlarmStatusTable 2 }
pwLostOfBundleStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"lost of bundle alarm "
::= { pwAlarmStatusTable 3 }
pwUnderRunStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"underrun alarm severity type"
::= { pwAlarmStatusTable 4 }
pwOverRunStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"overrun alarm severity type"
::= { pwAlarmStatusTable 5 }
pwLBitStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LBit alarm severity type"
::= { pwAlarmStatusTable 6 }
pwRBitStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RBit alarm severity type"
::= { pwAlarmStatusTable 7 }
pwIPConflictStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Conflictalarm severity type"
::= { pwAlarmStatusTable 8 }
ctrl1ETH1ELECAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 1 Eth 1 electrical Link down alarm"
::= { pwAlarmStatusTable 9 }
ctrl1ETH2ELECAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 1 Eth 2 electrical Link down alarm"
::= { pwAlarmStatusTable 10 }
ctrl1ETH1OPTIAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 1 Eth 1 optical Link down alarm"
::= { pwAlarmStatusTable 11 }
ctrl1ETH2OPTIAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 1 Eth 2 optical Link down alarm"
::= { pwAlarmStatusTable 12 }
eth1LOOPAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Eth 1 Looping alram"
::= { pwAlarmStatusTable 13 }
eth2LOOPAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Eth 2 Looping alram"
::= { pwAlarmStatusTable 14 }
ctrl2ETH1ELECAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 2 Eth 1 electrical Link down alarm"
::= { pwAlarmStatusTable 15 }
ctrl2ETH2ELECAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 2 Eth 2 electrical Link down alarm"
::= { pwAlarmStatusTable 16 }
ctrl2ETH1OPTIAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 2 Eth 1 optical Link down alarm"
::= { pwAlarmStatusTable 17 }
ctrl2ETH2OPTIAlarmStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"controller 2 Eth 2 optical Link down alarm"
::= { pwAlarmStatusTable 18 }
--
-- PW SFP Info Table
--
pwSfpInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSfpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"sfp information table"
::= {pwCtrlStatusTable 6}
pwSfpInfoEntry OBJECT-TYPE
SYNTAX PWSfpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in sfp information table."
INDEX { sfpIndex }
::= { pwSfpInfoTable 1 }
PWSfpInfoEntry ::= SEQUENCE {
sfpIndex INTEGER,
sfpEthIndex INTEGER,
sfpConnector INTEGER,
sfpTransceiver DisplayString,
sfpLinkLength DisplayString,
sfpTechnology DisplayString,
sfpEncoding DisplayString,
sfpLength9to125mm DisplayString,
sfpLength50to125mm DisplayString,
sfpLength62p5to125mm DisplayString,
sfpLength DisplayString,
sfpTemperature DisplayString,
sfpVcc DisplayString,
sfpTxBias DisplayString,
sfpTxPower DisplayString,
sfpRxPower DisplayString,
sfpDate DisplayString,
sfpVendorName DisplayString,
sfpOUI DisplayString,
sfpPN DisplayString,
sfpRev DisplayString,
sfpWavelength DisplayString
}
sfpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1~2, "
::= { pwSfpInfoEntry 1 }
sfpEthIndex OBJECT-TYPE
SYNTAX INTEGER {
eth1 (1),
eth2 (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"optical port"
::= { pwSfpInfoEntry 2 }
sfpConnector OBJECT-TYPE
SYNTAX INTEGER {
notavailable(1),
sc(2),
fiberchannelstyle1copper(3),
fiberchannelstyle2copper(4),
bnctnc(5),
fibrechannelcoaxialheader(6),
fiberJack(7),
lc(8),
mtrj(9),
mu(10),
sg(11),
optcalpigtail(12),
hssdcii(13),
copperpigtail(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP connector"
::= { pwSfpInfoEntry 3 }
sfpTransceiver OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP transceiver"
::= { pwSfpInfoEntry 4 }
sfpLinkLength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP link length"
::= { pwSfpInfoEntry 5 }
sfpTechnology OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP technology"
::= { pwSfpInfoEntry 6 }
sfpEncoding OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP encoding"
::= { pwSfpInfoEntry 7 }
sfpLength9to125mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 9/125 mm fiber"
::= { pwSfpInfoEntry 8 }
sfpLength50to125mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 50/125 mm fiber"
::= { pwSfpInfoEntry 9 }
sfpLength62p5to125mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 62.5/125 mm fiber"
::= { pwSfpInfoEntry 10 }
sfpLength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Length"
::= { pwSfpInfoEntry 11 }
sfpTemperature OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Temperature"
::= { pwSfpInfoEntry 12 }
sfpVcc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Vcc"
::= { pwSfpInfoEntry 13 }
sfpTxBias OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Tx Bias current"
::= { pwSfpInfoEntry 14 }
sfpTxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Tx power"
::= { pwSfpInfoEntry 15 }
sfpRxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 16 }
sfpDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 17 }
sfpVendorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 18 }
sfpOUI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 19 }
sfpPN OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 20 }
sfpRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 21 }
sfpWavelength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { pwSfpInfoEntry 22 }
--
-- PW ACR Status Table
--
pwACRStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWACRStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw ACR status Table."
::= { pwCtrlStatusTable 7 }
pwACRStatusEntry OBJECT-TYPE
SYNTAX PWACRStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Pw ACR Status Entry"
INDEX { pwACRIndex }
::= { pwACRStatusTable 1 }
PWACRStatusEntry ::= SEQUENCE {
pwACRStatusIndex INTEGER,
pwACRStatusPortID INTEGER,
pwACRStatusEnable INTEGER,
pwACRStatusStatus INTEGER,
pwACRDisconCnt INTEGER,
pwACRRestartCnt INTEGER,
pwACRCovariance DisplayString,
pwACRFreq DisplayString
}
pwACRStatusIndex OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR status Index."
::= { pwACRStatusEntry 1 }
pwACRStatusPortID OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR port id."
::= { pwACRStatusEntry 2 }
pwACRStatusEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
none(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The acr enable status."
::= { pwACRStatusEntry 3 }
pwACRStatusStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
acquisition(2),
tracking1(3),
tracking2(4),
tracking3(5),
tracking4(6),
tracking5(7),
none(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The acr tracking status."
::= { pwACRStatusEntry 4 }
pwACRDisconCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR discountinue count."
::= { pwACRStatusEntry 5 }
pwACRRestartCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR restart count."
::= { pwACRStatusEntry 6 }
pwACRCovariance OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR covariance."
::= { pwACRStatusEntry 7 }
pwACRFreq OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ACR Freq."
::= { pwACRStatusEntry 8 }
--
-- Current Performance Table
--
pwPerformanceTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 8}
pwCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Performance Table"
::= { pwPerformanceTable 1}
pwCurrentPerfEntry OBJECT-TYPE
SYNTAX PWCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { pwPortIndex }
::= { pwCurrentPerfTable 1 }
PWCurrentPerfEntry ::= SEQUENCE {
pwPortIndex INTEGER,
pwCurrentRxLost INTEGER,
pwCurrentJitBufUnderrun INTEGER,
pwCurrentJitBufOverrun INTEGER,
pwCurr15MinTimeElapsed INTEGER,
pwValid15MinInterval INTEGER,
pwCurrentEth1Loss INTEGER,
pwCurrentEth2Loss INTEGER
}
pwPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw perf portIndex 1-64"
::= { pwCurrentPerfEntry 1 }
pwCurrentRxLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Rx-Lost Counter. Rx-Lost is count for a boundle about ethernet Lost/ jump events Packets."
::= { pwCurrentPerfEntry 2 }
pwCurrentJitBufUnderrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current J-UR Counter. Underrun is count of jitter buffer underrun events."
::= { pwCurrentPerfEntry 3 }
pwCurrentJitBufOverrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current J-OR Counter. Overrun is count of jitter buffer overrun events."
::= { pwCurrentPerfEntry 4 }
pwCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { pwCurrentPerfEntry 5}
pwValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { pwCurrentPerfEntry 6}
pwCurrentEth1Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current eth1 los Counter."
::= { pwCurrentPerfEntry 7 }
pwCurrentEth2Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current eth2 los Counter."
::= { pwCurrentPerfEntry 8 }
--
-- Interval Performance Table
--
pwIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval Performance Table"
::= { pwPerformanceTable 2 }
pwIntervalPerfEntry OBJECT-TYPE
SYNTAX PWIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval performance entry"
INDEX { pwIntPortIndex, pwIntervalPerfNum }
::= { pwIntervalPerfTable 1 }
PWIntervalPerfEntry ::= SEQUENCE {
pwIntPortIndex INTEGER,
pwIntervalPerfNum INTEGER,
pwIntervalRxLost INTEGER,
pwIntervalJitBufUnderrun INTEGER,
pwIntervalJitBufOverrun INTEGER,
pwIntervalEth1Loss INTEGER,
pwIntervalEth2Loss INTEGER
}
pwIntPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { pwIntervalPerfEntry 1 }
pwIntervalPerfNum OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { pwIntervalPerfEntry 2 }
pwIntervalRxLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" interval rx-lost counter "
::= { pwIntervalPerfEntry 3}
pwIntervalJitBufUnderrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer underrun Counter "
::= { pwIntervalPerfEntry 4}
pwIntervalJitBufOverrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer overrun Counter "
::= { pwIntervalPerfEntry 5}
pwIntervalEth1Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth1 Loss Counter "
::= { pwIntervalPerfEntry 6}
pwIntervalEth2Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth2 Loss Counter "
::= { pwIntervalPerfEntry 7}
--
-- Total Performance Table
--
pwTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Performance Table"
::= { pwPerformanceTable 3 }
pwTotalPerfEntry OBJECT-TYPE
SYNTAX PWTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { pwTotalPortIndex }
::= { pwTotalPerfTable 1 }
PWTotalPerfEntry ::= SEQUENCE {
pwTotalPortIndex INTEGER,
pwTotalRxLost INTEGER,
pwTotalJitBufUnderrun INTEGER,
pwTotalJitBufOverrun INTEGER,
pwTotalEth1Loss INTEGER,
pwTotalEth2Loss INTEGER
}
pwTotalPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" total Counter in current 24 hours"
::= { pwTotalPerfEntry 1 }
pwTotalRxLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Rx-lost Counter in current 24 hours"
::= { pwTotalPerfEntry 2 }
pwTotalJitBufUnderrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Jitter buffer underrun Counter in current 24 hours"
::= { pwTotalPerfEntry 3}
pwTotalJitBufOverrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Jitter buffer overrun Counter in current 24 hours"
::= { pwTotalPerfEntry 4}
pwTotalEth1Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth1Loss Counter in current 24 hours"
::= { pwTotalPerfEntry 5}
pwTotalEth2Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth2Loss Counter in current 24 hours"
::= { pwTotalPerfEntry 6}
--
-- Seven Days Performance Table
--
pwSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { pwPerformanceTable 4}
pwSevenDaysPerfEntry OBJECT-TYPE
SYNTAX PWSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance table"
INDEX { pw7DaysPortIndex ,pwDaysIndex }
::= { pwSevenDaysPerfTable 1 }
PWSevenDaysPerfEntry ::= SEQUENCE {
pw7DaysPortIndex INTEGER,
pwDaysIndex INTEGER,
pwDateString DisplayString,
pw7DaysRxLost INTEGER,
pw7DaysJitBufUnderrun INTEGER,
pw7DaysJitBufOverrun INTEGER,
pw7DaysEth1Loss INTEGER,
pw7DaysEth2Loss INTEGER
}
pw7DaysPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..63)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days port index "
::= { pwSevenDaysPerfEntry 1 }
pwDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { pwSevenDaysPerfEntry 2 }
pwDateString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { pwSevenDaysPerfEntry 3 }
pw7DaysRxLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Rx-lost Counter in seven days"
::= { pwSevenDaysPerfEntry 4}
pw7DaysJitBufUnderrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer underrun Counter in seven days"
::= { pwSevenDaysPerfEntry 5}
pw7DaysJitBufOverrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer overrun Counter in seven days"
::= { pwSevenDaysPerfEntry 6}
pw7DaysEth1Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth1Loss Counter in seven days"
::= { pwSevenDaysPerfEntry 7}
pw7DaysEth2Loss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Eth2Loss Counter in seven days"
::= { pwSevenDaysPerfEntry 8}
--
-- bundle arp status table
--
pwBundleArpStatusTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 9 }
pwArpPrimaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWArpPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwBundleArpStatusTable 1}
pwArpPrimaryStatusEntry OBJECT-TYPE
SYNTAX PWArpPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwarpPrimaryNumIndex }
::= { pwArpPrimaryStatusTable 1 }
PWArpPrimaryStatusEntry ::= SEQUENCE {
pwarpPrimaryNumIndex INTEGER (1..64),
pwarpPrimarySrcIpAddress IpAddress,
pwarpPrimaryMacAddress DisplayString,
pwarpPrimarySVLANId INTEGER,
pwarpPrimaryCVLANId INTEGER,
pwarpPrimaryRxRequest Counter,
pwarpPrimaryTxReply Counter,
pwarpPrimaryTxRequest Counter,
pwarpPrimaryRxReply Counter,
pwisPrimaryBundleIp INTEGER
}
pwarpPrimaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~64) "
::= { pwArpPrimaryStatusEntry 1 }
pwarpPrimarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { pwArpPrimaryStatusEntry 2 }
pwarpPrimaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwArpPrimaryStatusEntry 3 }
pwarpPrimarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwArpPrimaryStatusEntry 4 }
pwarpPrimaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwArpPrimaryStatusEntry 5 }
pwarpPrimaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { pwArpPrimaryStatusEntry 6 }
pwarpPrimaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Reply counter"
::= { pwArpPrimaryStatusEntry 7 }
pwarpPrimaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Request counter"
::= { pwArpPrimaryStatusEntry 8 }
pwarpPrimaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { pwArpPrimaryStatusEntry 9 }
pwisPrimaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { pwArpPrimaryStatusEntry 10 }
--arp other
pwArpOtherStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWArpOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth phy electric Config Table."
::= { pwBundleArpStatusTable 2 }
pwArpOtherStatusEntry OBJECT-TYPE
SYNTAX PWArpOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { pwarpOtherNumIndex }
::= { pwArpOtherStatusTable 1 }
PWArpOtherStatusEntry ::= SEQUENCE {
pwarpOtherNumIndex INTEGER (1..8),
pwarpOtherSrcIpAddress IpAddress,
pwarpOtherMacAddress DisplayString,
pwarpOtherSVLANId INTEGER,
pwarpOtherCVLANId INTEGER,
pwarpOtherRxRequest Counter,
pwarpOtherRxReply Counter
}
pwarpOtherNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~8) "
::= { pwArpOtherStatusEntry 1 }
pwarpOtherSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { pwArpOtherStatusEntry 2 }
pwarpOtherMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwArpOtherStatusEntry 3 }
pwarpOtherSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwArpOtherStatusEntry 4 }
pwarpOtherCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwArpOtherStatusEntry 5 }
pwarpOtherRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { pwArpOtherStatusEntry 6 }
pwarpOtherRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { pwArpOtherStatusEntry 7 }
--arp Secondary
pwArpSecondaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWArpSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwBundleArpStatusTable 3}
pwArpSecondaryStatusEntry OBJECT-TYPE
SYNTAX PWArpSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwarpSecondaryNumIndex }
::= { pwArpSecondaryStatusTable 1 }
PWArpSecondaryStatusEntry ::= SEQUENCE {
pwarpSecondaryNumIndex INTEGER (1..64),
pwarpSecondarySrcIpAddress IpAddress,
pwarpSecondaryMacAddress DisplayString,
pwarpSecondarySVLANId INTEGER,
pwarpSecondaryCVLANId INTEGER,
pwarpSecondaryRxRequest Counter,
pwarpSecondaryTxReply Counter,
pwarpSecondaryTxRequest Counter,
pwarpSecondaryRxReply Counter,
pwisSecondaryBundleIp INTEGER
}
pwarpSecondaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~64) "
::= { pwArpSecondaryStatusEntry 1 }
pwarpSecondarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { pwArpSecondaryStatusEntry 2 }
pwarpSecondaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwArpSecondaryStatusEntry 3 }
pwarpSecondarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwArpSecondaryStatusEntry 4 }
pwarpSecondaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwArpSecondaryStatusEntry 5 }
pwarpSecondaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { pwArpSecondaryStatusEntry 6 }
pwarpSecondaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Reply counter"
::= { pwArpSecondaryStatusEntry 7 }
pwarpSecondaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Request counter"
::= { pwArpSecondaryStatusEntry 8 }
pwarpSecondaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { pwArpSecondaryStatusEntry 9 }
pwisSecondaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { pwArpSecondaryStatusEntry 10 }
--
-- bundle ping status table
--
pwBundlePingStatusTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 10}
pwPingPrimaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPingPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {pwBundlePingStatusTable 1}
pwPingPrimaryStatusEntry OBJECT-TYPE
SYNTAX PWPingPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pwpingPrimaryNumIndex }
::= { pwPingPrimaryStatusTable 1 }
PWPingPrimaryStatusEntry ::= SEQUENCE {
pwpingPrimaryNumIndex INTEGER (1..64),
pwpingPrimarySrcIpAddress IpAddress,
pwpingPrimaryMacAddress DisplayString,
pwpingPrimarySVLANId INTEGER,
pwpingPrimaryCVLANId INTEGER,
pwpingPrimaryRxRequest Counter,
pwpingPrimaryTxReply Counter,
pwpingPrimaryTxRequest Counter,
pwpingPrimaryRxReply Counter,
pwisPingPrimaryBundleIp INTEGER
}
pwpingPrimaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~64) "
::= { pwPingPrimaryStatusEntry 1 }
pwpingPrimarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { pwPingPrimaryStatusEntry 2 }
pwpingPrimaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwPingPrimaryStatusEntry 3 }
pwpingPrimarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwPingPrimaryStatusEntry 4 }
pwpingPrimaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwPingPrimaryStatusEntry 5 }
pwpingPrimaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { pwPingPrimaryStatusEntry 6 }
pwpingPrimaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Reply counter"
::= { pwPingPrimaryStatusEntry 7 }
pwpingPrimaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Request counter"
::= { pwPingPrimaryStatusEntry 8 }
pwpingPrimaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { pwPingPrimaryStatusEntry 9 }
pwisPingPrimaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { pwPingPrimaryStatusEntry 10 }
-- other
pwPingOtherStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPingOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {pwBundlePingStatusTable 2}
pwPingOtherStatusEntry OBJECT-TYPE
SYNTAX PWPingOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pwpingOtherNumIndex }
::= { pwPingOtherStatusTable 1 }
PWPingOtherStatusEntry ::= SEQUENCE {
pwpingOtherNumIndex INTEGER (1..8),
pwpingOtherSrcIpAddress IpAddress,
pwpingOtherMacAddress DisplayString,
pwpingOtherSVLANId INTEGER,
pwpingOtherCVLANId INTEGER,
pwpingOtherRxRequest Counter,
pwpingOtherRxReply Counter
}
pwpingOtherNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~8) "
::= { pwPingOtherStatusEntry 1 }
pwpingOtherSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { pwPingOtherStatusEntry 2 }
pwpingOtherMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwPingOtherStatusEntry 3 }
pwpingOtherSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwPingOtherStatusEntry 4 }
pwpingOtherCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwPingOtherStatusEntry 5 }
pwpingOtherRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { pwPingOtherStatusEntry 6 }
pwpingOtherRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { pwPingOtherStatusEntry 7 }
--ping Secondary
pwPingSecondaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPingSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {pwBundlePingStatusTable 3}
pwPingSecondaryStatusEntry OBJECT-TYPE
SYNTAX PWPingSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pwpingSecondaryNumIndex }
::= { pwPingSecondaryStatusTable 1 }
PWPingSecondaryStatusEntry ::= SEQUENCE {
pwpingSecondaryNumIndex INTEGER (1..64),
pwpingSecondarySrcIpAddress IpAddress,
pwpingSecondaryMacAddress DisplayString,
pwpingSecondarySVLANId INTEGER,
pwpingSecondaryCVLANId INTEGER,
pwpingSecondaryRxRequest Counter,
pwpingSecondaryTxReply Counter,
pwpingSecondaryTxRequest Counter,
pwpingSecondaryRxReply Counter,
pwisPingSecondaryBundleIp INTEGER
}
pwpingSecondaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~64) "
::= { pwPingSecondaryStatusEntry 1 }
pwpingSecondarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { pwPingSecondaryStatusEntry 2 }
pwpingSecondaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwPingSecondaryStatusEntry 3 }
pwpingSecondarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwPingSecondaryStatusEntry 4 }
pwpingSecondaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwPingSecondaryStatusEntry 5 }
pwpingSecondaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { pwPingSecondaryStatusEntry 6 }
pwpingSecondaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Reply counter"
::= { pwPingSecondaryStatusEntry 7 }
pwpingSecondaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Request counter"
::= { pwPingSecondaryStatusEntry 8 }
pwpingSecondaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { pwPingSecondaryStatusEntry 9 }
pwisPingSecondaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { pwPingSecondaryStatusEntry 10 }
--
-- IP Conflict
--
pwIpConflictTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWIpConflictEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle IP Conflict status table."
::= {pwCtrlStatusTable 11}
pwIpConflictEntry OBJECT-TYPE
SYNTAX PWIpConflictEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle IP Conflict status table."
INDEX { pwipConflictNumIndex }
::= { pwIpConflictTable 1 }
PWIpConflictEntry ::= SEQUENCE {
pwipConflictNumIndex INTEGER (1..16),
pwipConflictSrcIpAddress IpAddress,
pwipConflictMacAddress DisplayString,
pwipConflictSVLANId INTEGER,
pwipConflictCVLANId INTEGER
}
pwipConflictNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle IP Conflict Number Index(1~64) "
::= { pwIpConflictEntry 1 }
pwipConflictSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle IP Conflict Source IP."
::= { pwIpConflictEntry 2 }
pwipConflictMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bundle IP Conflict Source Mac (xx:xx:xx:xx:xx:xx)"
::= { pwIpConflictEntry 3 }
pwipConflictSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { pwIpConflictEntry 4 }
pwipConflictCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { pwIpConflictEntry 5 }
--
-- PseudWire Mode status Table
--
pwProtectModeStatusTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 12 }
pwModeSelectStatus OBJECT-TYPE
SYNTAX INTEGER {
mode0(1),
mode1(2),
mode2(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw protect mode select"
::= { pwProtectModeStatusTable 1 }
-- pwModeActionStatus OBJECT-TYPE
-- SYNTAX INTEGER {
-- nonrevertible(1),
-- revertible(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "pw protect mode action"
-- ::= { pwProtectModeStatusTable 2 }
pwCascadePortStatus OBJECT-TYPE
SYNTAX INTEGER {
eth1LinkUp(1),
eth2LinkUp(2),
eth1LinkDown(3),
eth2LinkDown(4),
na(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw protect cascade port"
::= { pwProtectModeStatusTable 3 }
pwCascadeChannelStatus OBJECT-TYPE
SYNTAX INTEGER {
notReady(1),
ready(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw protect cascade channel"
::= { pwProtectModeStatusTable 4 }
--
-- pw arival time statist table
--
pwArrivalTimeStatistTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 14 }
pwPriArrivalTimeStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPriArrivalTimeStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwArrivalTimeStatistTable 1}
pwPriArrivalTimeStatistEntry OBJECT-TYPE
SYNTAX PWPriArrivalTimeStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwPriEthStatistIndex }
::= { pwPriArrivalTimeStatistTable 1 }
PWPriArrivalTimeStatistEntry ::= SEQUENCE {
pwPriEthStatistIndex INTEGER (1..64),
pwPriEth1ReOrder DisplayString,
pwPriEth1RxLoss DisplayString,
pwPriEth1IPGMax DisplayString,
pwPriEth1IPGMin DisplayString,
pwPriEth1IPGCur DisplayString,
pwPriEth2ReOrder DisplayString,
pwPriEth2RxLoss DisplayString,
pwPriEth2IPGMax DisplayString,
pwPriEth2IPGMin DisplayString,
pwPriEth2IPGCur DisplayString
}
pwPriEthStatistIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist Index(1~64) "
::= { pwPriArrivalTimeStatistEntry 1 }
pwPriEth1ReOrder OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist reorder"
::= { pwPriArrivalTimeStatistEntry 2 }
pwPriEth1RxLoss OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist rx los"
::= { pwPriArrivalTimeStatistEntry 3 }
pwPriEth1IPGMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG MAX"
::= { pwPriArrivalTimeStatistEntry 4 }
pwPriEth1IPGMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG MIN"
::= { pwPriArrivalTimeStatistEntry 5 }
pwPriEth1IPGCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG Cur"
::= { pwPriArrivalTimeStatistEntry 6 }
pwPriEth2ReOrder OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth2 pri statist reorder"
::= { pwPriArrivalTimeStatistEntry 7 }
pwPriEth2RxLoss OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth2 pri statist rx los"
::= { pwPriArrivalTimeStatistEntry 8 }
pwPriEth2IPGMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG MAX"
::= { pwPriArrivalTimeStatistEntry 9 }
pwPriEth2IPGMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG MIN"
::= { pwPriArrivalTimeStatistEntry 10 }
pwPriEth2IPGCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG Cur"
::= { pwPriArrivalTimeStatistEntry 11 }
-- secondary
pwSecArrivalTimeStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSecArrivalTimeStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwArrivalTimeStatistTable 2}
pwSecArrivalTimeStatistEntry OBJECT-TYPE
SYNTAX PWSecArrivalTimeStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwSecEthStatistIndex }
::= { pwSecArrivalTimeStatistTable 1 }
PWSecArrivalTimeStatistEntry ::= SEQUENCE {
pwSecEthStatistIndex INTEGER (1..64),
pwSecEth1ReOrder DisplayString,
pwSecEth1RxLoss DisplayString,
pwSecEth1IPGMax DisplayString,
pwSecEth1IPGMin DisplayString,
pwSecEth1IPGCur DisplayString,
pwSecEth2ReOrder DisplayString,
pwSecEth2RxLoss DisplayString,
pwSecEth2IPGMax DisplayString,
pwSecEth2IPGMin DisplayString,
pwSecEth2IPGCur DisplayString
}
pwSecEthStatistIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist Index(1~64) "
::= { pwSecArrivalTimeStatistEntry 1 }
pwSecEth1ReOrder OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist reorder"
::= { pwSecArrivalTimeStatistEntry 2 }
pwSecEth1RxLoss OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth pri statist rx los"
::= { pwSecArrivalTimeStatistEntry 3 }
pwSecEth1IPGMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG MAX"
::= { pwSecArrivalTimeStatistEntry 4 }
pwSecEth1IPGMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG MIN"
::= { pwSecArrivalTimeStatistEntry 5 }
pwSecEth1IPGCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth1 statist IPG Cur"
::= { pwSecArrivalTimeStatistEntry 6 }
pwSecEth2ReOrder OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth2 pri statist reorder"
::= { pwSecArrivalTimeStatistEntry 7 }
pwSecEth2RxLoss OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle eth2 pri statist rx los"
::= { pwSecArrivalTimeStatistEntry 8 }
pwSecEth2IPGMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG MAX"
::= { pwSecArrivalTimeStatistEntry 9 }
pwSecEth2IPGMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG MIN"
::= { pwSecArrivalTimeStatistEntry 10 }
pwSecEth2IPGCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW eth2 statist IPG Cur"
::= { pwSecArrivalTimeStatistEntry 11 }
--
-- bundle Round Trip statist table
--
pwRoundTripStatistTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 15 }
pwPriRoundTripStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPriRoundTripStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwRoundTripStatistTable 1}
pwPriRoundTripStatistEntry OBJECT-TYPE
SYNTAX PWPriRoundTripStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwPriRoundTripIndex }
::= { pwPriRoundTripStatistTable 1 }
PWPriRoundTripStatistEntry ::= SEQUENCE {
pwPriRoundTripIndex INTEGER (1..64),
pwPriRoundTripSeq INTEGER,
pwPriRoundTripSeqLoss INTEGER,
pwPriRoundTripIP DisplayString,
pwPriRoundTripCur DisplayString,
pwPriRoundTripMin DisplayString,
pwPriRoundTripMax DisplayString
}
pwPriRoundTripIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri Round Trip Index(1~64) "
::= { pwPriRoundTripStatistEntry 1 }
pwPriRoundTripSeq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri Round Trip Seq "
::= { pwPriRoundTripStatistEntry 2 }
pwPriRoundTripSeqLoss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri Round Trip Seq los"
::= { pwPriRoundTripStatistEntry 3 }
pwPriRoundTripIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bundle Pri Round Trip IP Address"
::= { pwPriRoundTripStatistEntry 4 }
pwPriRoundTripCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Pri Round Trip Cur"
::= { pwPriRoundTripStatistEntry 5 }
pwPriRoundTripMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Pri Round Trip MIN"
::= { pwPriRoundTripStatistEntry 6 }
pwPriRoundTripMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Pri Round Trip Max"
::= { pwPriRoundTripStatistEntry 7 }
-- secondary
pwSecRoundTripStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSecRoundTripStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwRoundTripStatistTable 2}
pwSecRoundTripStatistEntry OBJECT-TYPE
SYNTAX PWSecRoundTripStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwSecRoundTripIndex }
::= { pwSecRoundTripStatistTable 1 }
PWSecRoundTripStatistEntry ::= SEQUENCE {
pwSecRoundTripIndex INTEGER (1..64),
pwSecRoundTripSeq INTEGER,
pwSecRoundTripSeqLoss INTEGER,
pwSecRoundTripIP DisplayString,
pwSecRoundTripCur DisplayString,
pwSecRoundTripMin DisplayString,
pwSecRoundTripMax DisplayString
}
pwSecRoundTripIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec Round Trip Index(1~64) "
::= { pwSecRoundTripStatistEntry 1 }
pwSecRoundTripSeq OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec Round Trip Seq "
::= { pwSecRoundTripStatistEntry 2 }
pwSecRoundTripSeqLoss OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec Round Trip Seq los"
::= { pwSecRoundTripStatistEntry 3 }
pwSecRoundTripIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bundle Sec Round Trip IP Address"
::= { pwSecRoundTripStatistEntry 4 }
pwSecRoundTripCur OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Sec Round Trip Cur"
::= { pwSecRoundTripStatistEntry 5 }
pwSecRoundTripMin OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Sec Round Trip MIN"
::= { pwSecRoundTripStatistEntry 6 }
pwSecRoundTripMax OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PW Sec Round Trip Max"
::= { pwSecRoundTripStatistEntry 7 }
--
-- bundle Protect statist table
--
pwProtectStatistTable OBJECT IDENTIFIER ::= { pwCtrlStatusTable 16 }
pwPriProtectStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWPriProtectStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwProtectStatistTable 1}
pwPriProtectStatistEntry OBJECT-TYPE
SYNTAX PWPriProtectStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwPriProtectIndex }
::= { pwPriProtectStatistTable 1 }
PWPriProtectStatistEntry ::= SEQUENCE {
pwPriProtectIndex INTEGER (1..64),
pwPriEth1Linkstat INTEGER,
pwPriEth2Linkstat INTEGER,
pwPriEth1RxSeqNum INTEGER,
pwPriEth2RxSeqNum INTEGER,
pwPriEth1RxSeqLos INTEGER,
pwPriEth2RxSeqLos INTEGER,
pwPriEth1RxJBLos INTEGER,
pwPriEth2RxJBLos INTEGER,
pwPriDiffDelay DisplayString
}
pwPriProtectIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri protect Index(1~64) "
::= { pwPriProtectStatistEntry 1 }
pwPriEth1Linkstat OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth1 Round Trip Seq "
::= { pwPriProtectStatistEntry 2 }
pwPriEth2Linkstat OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth2 Round Trip Seq "
::= { pwPriProtectStatistEntry 3 }
pwPriEth1RxSeqNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth1 Seq Num"
::= { pwPriProtectStatistEntry 4 }
pwPriEth2RxSeqNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth2 Seq Num "
::= { pwPriProtectStatistEntry 5 }
pwPriEth1RxSeqLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth1 Seq los"
::= { pwPriProtectStatistEntry 6 }
pwPriEth2RxSeqLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth2 Seq Los "
::= { pwPriProtectStatistEntry 7 }
pwPriEth1RxJBLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth1 jb los"
::= { pwPriProtectStatistEntry 8 }
pwPriEth2RxJBLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri eth2 jb Los "
::= { pwPriProtectStatistEntry 9 }
pwPriDiffDelay OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Pri diff delay "
::= { pwPriProtectStatistEntry 10 }
-- secondary
pwSecProtectStatistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSecProtectStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {pwProtectStatistTable 2}
pwSecProtectStatistEntry OBJECT-TYPE
SYNTAX PWSecProtectStatistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { pwSecProtectIndex }
::= { pwSecProtectStatistTable 1 }
PWSecProtectStatistEntry ::= SEQUENCE {
pwSecProtectIndex INTEGER (1..64),
pwSecEth1Linkstat INTEGER,
pwSecEth2Linkstat INTEGER,
pwSecEth1RxSeqNum INTEGER,
pwSecEth2RxSeqNum INTEGER,
pwSecEth1RxSeqLos INTEGER,
pwSecEth2RxSeqLos INTEGER,
pwSecEth1RxJBLos INTEGER,
pwSecEth2RxJBLos INTEGER,
pwSecDiffDelay DisplayString
}
pwSecProtectIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec protect Index(1~64) "
::= { pwSecProtectStatistEntry 1 }
pwSecEth1Linkstat OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth1 Round Trip Seq "
::= { pwSecProtectStatistEntry 2 }
pwSecEth2Linkstat OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth2 Round Trip Seq "
::= { pwSecProtectStatistEntry 3 }
pwSecEth1RxSeqNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth1 Seq Num"
::= { pwSecProtectStatistEntry 4 }
pwSecEth2RxSeqNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth2 Seq Num "
::= { pwSecProtectStatistEntry 5 }
pwSecEth1RxSeqLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth1 Seq los"
::= { pwSecProtectStatistEntry 6 }
pwSecEth2RxSeqLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth2 Seq Los "
::= { pwSecProtectStatistEntry 7 }
pwSecEth1RxJBLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth1 jb los"
::= { pwSecProtectStatistEntry 8 }
pwSecEth2RxJBLos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec eth2 jb Los "
::= { pwSecProtectStatistEntry 9 }
pwSecDiffDelay OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Sec diff delay "
::= { pwSecProtectStatistEntry 10 }
--
-- Sec PseudWire Delay Info Table
--
pwSecBundleDelayInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWSecBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"sec pw delay info table"
::= { pwCtrlStatusTable 18 }
pwSecBundleDelayInfoEntry OBJECT-TYPE
SYNTAX PWSecBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw Delay Info entry"
INDEX { pwSecInfoIndex }
::= { pwSecBundleDelayInfoTable 1 }
PWSecBundleDelayInfoEntry ::= SEQUENCE {
pwSecInfoIndex INTEGER,
pwSecInfoPort INTEGER,
pwSecCellNum INTEGER,
pwSecJitterDelaySt INTEGER,
pwSecJitterSizeSt INTEGER,
pwSecPropDelay DisplayString,
pwSecPktSize DisplayString,
pwSecOverHead DisplayString,
pwSecEthernetBW DisplayString,
pwSecTotalBW DisplayString
}
pwSecInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pseudo Wire Index 1~64"
::= { pwSecBundleDelayInfoEntry 1 }
pwSecInfoPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pseudo Wire bundle port 1~64"
::= { pwSecBundleDelayInfoEntry 2 }
pwSecCellNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw cell number"
::= { pwSecBundleDelayInfoEntry 3 }
pwSecJitterDelaySt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw jitter delay"
::= { pwSecBundleDelayInfoEntry 4 }
pwSecJitterSizeSt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw jitter size"
::= { pwSecBundleDelayInfoEntry 5 }
pwSecPropDelay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw jitter prop delay"
::= { pwSecBundleDelayInfoEntry 6 }
pwSecPktSize OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw pkt size"
::= { pwSecBundleDelayInfoEntry 7 }
pwSecOverHead OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec Pw over head"
::= { pwSecBundleDelayInfoEntry 8 }
pwSecEthernetBW OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec pw ethernet bw"
::= { pwSecBundleDelayInfoEntry 9 }
pwSecTotalBW OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sec pw total bw"
::= { pwSecBundleDelayInfoEntry 10 }
--
-- Standby PseudWire Statics Table
--
pwStandbyStaticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PWStandbyStaticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw Standby statics table"
::= { pwCtrlStatusTable 20 }
pwStandbyStaticsEntry OBJECT-TYPE
SYNTAX PWStandbyStaticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"pw statics entry"
INDEX { pwStandbyIndex }
::= { pwStandbyStaticsTable 1 }
PWStandbyStaticsEntry ::= SEQUENCE {
pwStandbyIndex INTEGER,
pwStandbyStaticsPort INTEGER,
pwStandbyJitBufUnderRun INTEGER,
pwStandbyJitBufOverRun INTEGER,
pwStandbyJitBufMin INTEGER,
pwStandbyJitBufMax INTEGER,
pwStandbyJitBufDepth INTEGER,
pwStandbyLBitCount INTEGER,
pwStandbyRBitCount INTEGER,
pwStandbyTxGoodCount INTEGER,
pwStandbyRxGoodCount INTEGER,
pwStandbyRxLostCount INTEGER,
pwStandbyLink INTEGER,
pwStandbySizeError INTEGER,
pwStandbyRxAISAlm INTEGER,
pwStandbyPath INTEGER,
pwStandbyReOrderCount INTEGER
}
pwStandbyIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire Index 1~64"
::= { pwStandbyStaticsEntry 1 }
pwStandbyStaticsPort OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pseudo Wire bundle port 1~64"
::= { pwStandbyStaticsEntry 2 }
pwStandbyJitBufUnderRun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter uv"
::= { pwStandbyStaticsEntry 3 }
pwStandbyJitBufOverRun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter ov"
::= { pwStandbyStaticsEntry 4 }
pwStandbyJitBufMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter min"
::= { pwStandbyStaticsEntry 5 }
pwStandbyJitBufMax OBJECT-TYPE
SYNTAX INTEGER (1..1048575)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter max"
::= { pwStandbyStaticsEntry 6 }
pwStandbyJitBufDepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw jitter depth"
::= { pwStandbyStaticsEntry 7 }
pwStandbyLBitCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pw l-bit error"
::= { pwStandbyStaticsEntry 8 }
pwStandbyRBitCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw r-bit error"
::= { pwStandbyStaticsEntry 9 }
pwStandbyTxGoodCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw tx good pkt"
::= { pwStandbyStaticsEntry 10 }
pwStandbyRxGoodCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx good pkt"
::= { pwStandbyStaticsEntry 11 }
pwStandbyRxLostCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx lost count"
::= { pwStandbyStaticsEntry 12 }
pwStandbyLink OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw link status"
::= { pwStandbyStaticsEntry 13 }
pwStandbySizeError OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2),
cas(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw size error"
::= { pwStandbyStaticsEntry 14 }
pwStandbyRxAISAlm OBJECT-TYPE
SYNTAX INTEGER{
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw rx ais alm"
::= { pwStandbyStaticsEntry 15 }
pwStandbyPath OBJECT-TYPE
SYNTAX INTEGER{
pri(1),
sec(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw path"
::= { pwStandbyStaticsEntry 16 }
pwStandbyReOrderCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"pw re order count"
::= { pwStandbyStaticsEntry 17 }
--======================================================================--
--
-- Any-Ds1 Protection
--
anyds1Protection OBJECT IDENTIFIER ::= { controller 36 }
anyds1Enable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Any-Ds1 Enable/Disable."
::= { anyds1Protection 1 }
anyds1Map OBJECT-TYPE
SYNTAX INTEGER {
tsimap1(1),
tsimap2(2),
tsimap3(3),
tsimap4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Any-Ds1 Using TSI Map."
::= { anyds1Protection 2 }
anyds1ActionResponse OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Any-Ds1 action response."
::= { anyds1Protection 3 }
--
-- Any-Ds1 Creation
--
anyds1CreationTable OBJECT IDENTIFIER ::= { anyds1Protection 4 }
ds1CircuitGroup OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"group number for protected port, 0 means individual."
::= { anyds1CreationTable 1 }
ds1PrimarySlot OBJECT-TYPE
SYNTAX Anyds1Slot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary slot number."
::= { anyds1CreationTable 2 }
ds1PrimaryPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary port number."
::= { anyds1CreationTable 3 }
ds1PrimaryStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary start time slot."
::= { anyds1CreationTable 4 }
ds1SecondarySlot OBJECT-TYPE
SYNTAX Anyds1Slot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary slot number."
::= { anyds1CreationTable 5 }
ds1SecondaryPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary port number."
::= { anyds1CreationTable 6 }
ds1SecondaryStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary start time slot."
::= { anyds1CreationTable 7 }
ds1ProtectedSlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected Slot A~D, 1~12."
::= { anyds1CreationTable 8 }
ds1ProtectedPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected Port 1~12."
::= { anyds1CreationTable 9 }
ds1ProtectedStartTS OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Protected start time slot index."
::= { anyds1CreationTable 10 }
ds1ProtectCount OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Total channel number."
::= { anyds1CreationTable 11 }
ds1SwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { anyds1CreationTable 12 }
ds1DataVoice OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Data or Voice"
::= { anyds1CreationTable 13 }
ds1SetCommand OBJECT-TYPE
SYNTAX INTEGER {
check-set(1),
force-set(2),
force-switch(3),
delete-1(4),
-- delete-all(5),
-- clearAndSet(6),
lock-working(11),
lock-primary(12),
lock-secondary(13),
unlock(14),
change-switch-mode(21)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set command:
1: check and set Any-Ds1;
2: force set Any-Ds1;
3: force switch a Any-Ds1;
4: delete a Any-Ds1;
5: delete all;
11: lock on working;
12: lock on primary;
13: lock on secondary;
14: unlock"
::= { anyds1CreationTable 14 }
--
-- Any-Ds1 Information
--
anyds1InfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Anyds1InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DS0-SNCP Protection Information Table"
::= { anyds1Protection 5 }
anyds1InfoEntry OBJECT-TYPE
SYNTAX Anyds1InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Any-Ds1 Protection Information Entry"
INDEX { anyds1Index }
::= { anyds1InfoTable 1 }
Anyds1InfoEntry ::= SEQUENCE {
anyds1Index INTEGER,
anyds1Group INTEGER,
anyds1PrimarySlot Anyds1Slot,
anyds1PrimaryPort MapPortID,
anyds1SecondarySlot Anyds1Slot,
anyds1SecondaryPort MapPortID,
anyds1WorkingOn INTEGER,
anyds1DataVoice INTEGER,
anyds1SwitchMode INTEGER,
anyds1ForceSwitch INTEGER,
anyds1DeleteProtection INTEGER
}
anyds1Index OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Any-ds1 Index."
::= { anyds1InfoEntry 1 }
anyds1Group OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Any-ds1 Gruop number"
::= { anyds1InfoEntry 2 }
anyds1PrimarySlot OBJECT-TYPE
SYNTAX Anyds1Slot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary slot number."
::= { anyds1InfoEntry 3 }
anyds1PrimaryPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary port number."
::= { anyds1InfoEntry 4 }
anyds1SecondarySlot OBJECT-TYPE
SYNTAX Anyds1Slot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary slot number."
::= { anyds1InfoEntry 5 }
anyds1SecondaryPort OBJECT-TYPE
SYNTAX MapPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary port number."
::= { anyds1InfoEntry 6 }
anyds1WorkingOn OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working on primary or secondary."
::= { anyds1InfoEntry 7 }
anyds1DataVoice OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2),
voiceWithoutAu(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Data or Voice"
::= { anyds1InfoEntry 8 }
anyds1SwitchMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch mode"
::= { anyds1InfoEntry 9 }
anyds1ForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
no(1),
force-switch(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force switch to standby TS."
::= { anyds1InfoEntry 10 }
anyds1DeleteProtection OBJECT-TYPE
SYNTAX INTEGER {
no(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete protection."
::= { anyds1InfoEntry 11 }
--
-- Any-Ds1 Total Group Counter
--
anyds1TotalCountTable OBJECT IDENTIFIER ::= { anyds1Protection 6 }
ds1TotalGroup OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"group number counter."
::= { anyds1TotalCountTable 1 }
--======================================================================--
--
-- Uplink inband
--
uplinkInbandTable OBJECT IDENTIFIER ::= { controller 37 }
uplinkEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Uplink Enable/Disable."
::= { uplinkInbandTable 1 }
uplinkVlan OBJECT-TYPE
SYNTAX INTEGER {
off(1),
cvlan(2),
svlan(3),
qinq(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN SWITCH."
::= { uplinkInbandTable 2 }
uplinkCvlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"C VLAN ID (1..4094)"
::= { uplinkInbandTable 3 }
uplinkSvlanId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"S VLAN ID(1..4094) "
::= { uplinkInbandTable 4 }
uplinkTpidId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SPlease Input: 0~9, A~F"
::= { uplinkInbandTable 5 }
--======================================================================--
--
-- AdvancedStatus
--
advancedStatusTable OBJECT IDENTIFIER ::= { controller 38 }
--
-- DPLL status Display Table
--
dpllStatusTable OBJECT IDENTIFIER ::= { advancedStatusTable 1 }
dpllPriStatusTable OBJECT IDENTIFIER ::= { dpllStatusTable 1 }
deviceCalibration OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"device calibration"
::= { dpllPriStatusTable 1 }
signalatXAXB OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll signal at xaxb pins"
::= { dpllPriStatusTable 2 }
lockingtoXAXB OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll locking to xaxb pins"
::= { dpllPriStatusTable 3 }
smbustimeoutError OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll smbus timeout error"
::= { dpllPriStatusTable 4 }
dpllInput1Status OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
ooflos(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input1 status"
::= { dpllPriStatusTable 5 }
dpllInput2Status OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
ooflos(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 status"
::= { dpllPriStatusTable 6 }
dpllLockStatus OBJECT-TYPE
SYNTAX INTEGER {
lock(1),
freerun(2),
unlock(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 lock status"
::= { dpllPriStatusTable 7 }
dpllCalStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 calibration"
::= { dpllPriStatusTable 8 }
dpllInputSticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input status Sticky"
::= { dpllPriStatusTable 9 }
dpllLockSticky OBJECT-TYPE
SYNTAX INTEGER {
lock(1),
freerun(2),
unlock(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input lock Sticky"
::= { dpllPriStatusTable 10 }
dpllCalSticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 calibration"
::= { dpllPriStatusTable 11 }
dpllInput2Sticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 status Sticky"
::= { dpllPriStatusTable 12 }
-- standby
dpllStandbyStatusTable OBJECT IDENTIFIER ::= { dpllStatusTable 2 }
standbydeviceCalibration OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"device calibration"
::= { dpllStandbyStatusTable 1 }
standbysignalatXAXB OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll signal at xaxb pins"
::= { dpllStandbyStatusTable 2 }
standbylockingtoXAXB OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll locking to xaxb pins"
::= { dpllStandbyStatusTable 3 }
standbysmbustimeoutError OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll smbus timeout error"
::= { dpllStandbyStatusTable 4 }
standbydpllInput1Status OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
ooflos(4),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input1 status"
::= { dpllStandbyStatusTable 5 }
standbydpllInput2Status OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
ooflos(4),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input1 status"
::= { dpllStandbyStatusTable 6 }
standbydpllLockStatus OBJECT-TYPE
SYNTAX INTEGER {
lock(1),
freerun(2),
unlock(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 lock status"
::= { dpllStandbyStatusTable 7 }
standbydpllCalStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 calibration"
::= { dpllStandbyStatusTable 8 }
standbydpllInputSticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input status Sticky"
::= { dpllStandbyStatusTable 9 }
standbydpllLockSticky OBJECT-TYPE
SYNTAX INTEGER {
lock(1),
freerun(2),
unlock(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input lock Sticky"
::= { dpllStandbyStatusTable 10 }
standbydpllCalSticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
yes(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 calibration"
::= { dpllStandbyStatusTable 11 }
standbydpllInput2Sticky OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
los(2),
oof(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dpll input2 status Sticky"
::= { dpllStandbyStatusTable 12 }
--
-- backplane Sync status table
--
backPlaneSyncStatusTable OBJECT IDENTIFIER ::= { advancedStatusTable 2 }
bpTxJBSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Tx JB sync status"
::= { backPlaneSyncStatusTable 1 }
bpTxSyncWordError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Tx syncword error"
::= { backPlaneSyncStatusTable 2 }
bpTx1stframeError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Tx 1st frame error"
::= { backPlaneSyncStatusTable 3 }
bpTxseqNumError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Tx seq number error"
::= { backPlaneSyncStatusTable 4 }
bpTxFPSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Tx frame pulse sync status"
::= { backPlaneSyncStatusTable 5 }
bpRxJBSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx JB sync status"
::= { backPlaneSyncStatusTable 6 }
bpRxSyncWordDone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx syncword done"
::= { backPlaneSyncStatusTable 7 }
bpRxSyncWordDoneError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx syncword doneerror"
::= { backPlaneSyncStatusTable 8 }
bpRxSyncWordError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx syncword error"
::= { backPlaneSyncStatusTable 9 }
bpRxseqNumError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx seq number error"
::= { backPlaneSyncStatusTable 10 }
bpRxPCMError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx PCM error"
::= { backPlaneSyncStatusTable 11 }
bpRxBDError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP Rx bd error"
::= { backPlaneSyncStatusTable 12 }
bpModeChnageCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BP mode change count"
::= { backPlaneSyncStatusTable 13 }
--
-- HDLC status Display Table
--
hdlcStatusTable OBJECT IDENTIFIER ::= { advancedStatusTable 3 }
--pri
hdlcPriStatusTable OBJECT IDENTIFIER ::= { hdlcStatusTable 1 }
priFpgaRxFCSOk OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx FCS_ok(0x400e1008)"
::= { hdlcPriStatusTable 1 }
priFpgaRxFCSerr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx FCS_err(0x400e100c)"
::= { hdlcPriStatusTable 2 }
priFpgaRxFifoWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx fifo_w(0x400e2000)"
::= { hdlcPriStatusTable 3 }
priFpgaRxFifoRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx fifo_r(0x400e2004)"
::= { hdlcPriStatusTable 4 }
priFpgaTxFifoWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary tx fifo_w_pkt8q(0x400e0000)"
::= { hdlcPriStatusTable 5 }
priFpgaTxFifoRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary tx fifo_r_pkt8q(0x400e0004)"
::= { hdlcPriStatusTable 6 }
priFpgaRxFlagCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx Flag_cnt(0x400e1000)"
::= { hdlcPriStatusTable 7 }
priFpgaRxFlagAbort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx Flag_abort(0x400e1004)"
::= { hdlcPriStatusTable 8 }
priFpgaRxLink OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary rx Link(0x400e1010)"
::= { hdlcPriStatusTable 9 }
priCpuInbandIsr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary cpu inband_isr"
::= { hdlcPriStatusTable 10 }
priCpuHdlcRxTadk OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary cpu hdlc_rx_task"
::= { hdlcPriStatusTable 11 }
priCpuHdlcRxPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary cpu hdlc_rx_pkt"
::= { hdlcPriStatusTable 12 }
priCpuHdlcTxPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary cpu hdlc_tx_inband_pkt"
::= { hdlcPriStatusTable 13 }
--sec
hdlcSecStatusTable OBJECT IDENTIFIER ::= { hdlcStatusTable 2 }
secFpgaRxFCSOk OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx FCS_ok(0x400e1008)"
::= { hdlcSecStatusTable 1 }
secFpgaRxFCSerr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx FCS_err(0x400e100c)"
::= { hdlcSecStatusTable 2 }
secFpgaRxFifoWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx fifo_w(0x400e2000)"
::= { hdlcSecStatusTable 3 }
secFpgaRxFifoRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx fifo_r(0x400e2004)"
::= { hdlcSecStatusTable 4 }
secFpgaTxFifoWrite OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary tx fifo_w_pkt8q(0x400e0000)"
::= { hdlcSecStatusTable 5 }
secFpgaTxFifoRead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary tx fifo_r_pkt8q(0x400e0004)"
::= { hdlcSecStatusTable 6 }
secFpgaRxFlagCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx Flag_cnt(0x400e1000)"
::= { hdlcSecStatusTable 7 }
secFpgaRxFlagAbort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx Flag_abort(0x400e1004)"
::= { hdlcSecStatusTable 8 }
secFpgaRxLink OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary rx Link(0x400e1010)"
::= { hdlcSecStatusTable 9 }
secCpuInbandIsr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary cpu inband_isr"
::= { hdlcSecStatusTable 10 }
secCpuHdlcRxTadk OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary cpu hdlc_rx_task"
::= { hdlcSecStatusTable 11 }
secCpuHdlcRxPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary cpu hdlc_rx_pkt"
::= { hdlcSecStatusTable 12 }
secCpuHdlcTxPkt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary cpu hdlc_tx_inband_pkt"
::= { hdlcSecStatusTable 13 }
--
-- rs485 max delay
--
rs485StatusTable OBJECT IDENTIFIER ::= { advancedStatusTable 4 }
rs485MaxDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs485MaxDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display slot rs485 max delay"
::= { rs485StatusTable 1 }
rs485MaxDelayEntry OBJECT-TYPE
SYNTAX Rs485MaxDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot model entry"
INDEX { rs485SlotIndex }
::= { rs485MaxDelayTable 1 }
Rs485MaxDelayEntry ::= SEQUENCE {
rs485SlotIndex GenSlotID,
rs485MaxDelay DisplayString,
rs485NoRxCnt INTEGER,
rs485ModelType GenModelType
}
rs485SlotIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { rs485MaxDelayEntry 1 }
rs485MaxDelay OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card max delay"
::= { rs485MaxDelayEntry 2 }
rs485NoRxCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card no rx counter"
::= { rs485MaxDelayEntry 3 }
rs485ModelType OBJECT-TYPE
SYNTAX GenModelType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of current plug-in card"
::= { rs485MaxDelayEntry 4 }
--
-- rs485 TX/RX overlap
--
rs485TxRxOverlapTable OBJECT IDENTIFIER ::= { rs485StatusTable 2 }
rs485TxRxOverlap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"rs485 tx/rx overlap."
::= { rs485TxRxOverlapTable 1 }
--
-- advanced status cmd
--
advancedCmdTable OBJECT IDENTIFIER ::= { advancedStatusTable 5 }
--
-- rs485 max delay clean
--
rs485MaxDelayClearTable OBJECT IDENTIFIER ::= { advancedCmdTable 1 }
delayClearAll OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Uplink Enable/Disable."
::= { rs485MaxDelayClearTable 1 }
delayClearBySlot OBJECT-TYPE
SYNTAX MapSetSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Slot A~D and 1~12, total 16 slots."
::= { rs485MaxDelayClearTable 2 }
--
-- rs485 tx rx debug enable
--
rs485DebugCmdTable OBJECT IDENTIFIER ::= { advancedCmdTable 2 }
rs485txRxDebug OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tx rx debug Enable/Disable."
::= { rs485DebugCmdTable 1 }
rs485txRxDebugStClear OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tx rx debug Enable/Disable."
::= { rs485DebugCmdTable 2 }
debugCmd3 OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tx rx debug Enable/Disable."
::= { rs485DebugCmdTable 3 }
debugCmd4 OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tx rx debug Enable/Disable."
::= { rs485DebugCmdTable 4 }
debugCmd5 OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tx rx debug Enable/Disable."
::= { rs485DebugCmdTable 5 }
--
-- debug table
--
debugStatesTable OBJECT IDENTIFIER ::= { advancedStatusTable 6 }
debugList OBJECT IDENTIFIER ::= { debugStatesTable 1 }
bufferFull1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug1"
::= { debugList 1 }
bufferFull2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug2"
::= { debugList 2 }
irc1IntcMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug3"
::= { debugList 3 }
irc2TimeOut OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug4"
::= { debugList 4 }
irc2RemoteTimeOut OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug5"
::= { debugList 5 }
irc2Ready OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug6"
::= { debugList 6 }
debug7 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug7"
::= { debugList 7 }
debug8 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug8"
::= { debugList 8 }
debug9 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug9"
::= { debugList 9 }
debug10 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug10"
::= { debugList 10 }
debug11 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug11"
::= { debugList 11 }
debug12 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug12"
::= { debugList 12 }
debug13 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug13"
::= { debugList 13 }
debug14 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug14"
::= { debugList 14 }
debug15 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug15"
::= { debugList 15 }
debug16 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug16"
::= { debugList 16 }
debug17 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug17"
::= { debugList 17 }
debug18 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug18"
::= { debugList 18 }
debug19 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug19"
::= { debugList 19 }
debug20 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug20"
::= { debugList 20 }
debug21 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug21"
::= { debugList 21 }
debug22 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug22"
::= { debugList 22 }
debug23 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug23"
::= { debugList 23 }
debug24 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug24"
::= { debugList 24 }
debug25 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug25"
::= { debugList 25 }
debug26 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug26"
::= { debugList 26 }
debug27 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug27"
::= { debugList 27 }
debug28 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug28"
::= { debugList 28 }
debug29 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug29"
::= { debugList 29 }
debug30 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..65) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"debug30"
::= { debugList 30 }
--======================================================================--
--======================================================================--
-- trap MIB
--======================================================================--
--======================================================================--
localTrap TRAP-TYPE
ENTERPRISE loop-AM3440-CCPB-A
VARIABLES { ccAlarmQueueString,
ccAlarmType,
ccAlarmModel,
ccAlarmSlot,
ccAlarmPort,
ccAlarmSeverity,
ccAlarmLink ,
ccAlarmSubrack}
DESCRIPTION
"Local alarm trap"
::= 3
remoteTrap TRAP-TYPE
ENTERPRISE loop-AM3440-CCPB-A
VARIABLES {ccAlarmQueueString}
DESCRIPTION
"remote alarm trap"
::= 4
remove2Trap TRAP-TYPE
ENTERPRISE loop-AM3440-CCPB-A
VARIABLES { ccAlarmQueueString,
ccAlarmType,
ccAlarmModel,
ccAlarmSlot,
ccAlarmPort,
ccAlarmSeverity,
ccAlarmLink ,
ccAlarmSubrack}
DESCRIPTION
"Local alarm trap remove for old version"
::= 5
removeTrap TRAP-TYPE
ENTERPRISE loop-AM3440-CCPB-A
VARIABLES { ccAlarmQueueString,
ccAlarmType,
ccAlarmModel,
ccAlarmSlot,
ccAlarmPort,
ccAlarmSeverity,
ccAlarmLink ,
ccAlarmSubrack}
DESCRIPTION
"Local alarm trap remove"
::= 9
ccNotification OBJECT IDENTIFIER ::= { loop-AM3440-CCPB-A 0 }
v3LocalTrap NOTIFICATION-TYPE
OBJECTS { ccAlarmQueueString,
ccAlarmType,
ccAlarmModel,
ccAlarmSlot,
ccAlarmPort,
ccAlarmSeverity,
ccAlarmLink ,
ccAlarmSubrack}
STATUS current
DESCRIPTION
"Local alarm trap"
::= { ccNotification 1 }
v3RemoveTrap NOTIFICATION-TYPE
OBJECTS { ccAlarmQueueString,
ccAlarmType,
ccAlarmModel,
ccAlarmSlot,
ccAlarmPort,
ccAlarmSeverity,
ccAlarmLink ,
ccAlarmSubrack}
STATUS current
DESCRIPTION
"Local alarm trap"
::= { ccNotification 2 }
--======================================================================--
--======================================================================--
-- e1-card MIB
--======================================================================--
-- E1
-- lineControlTable OBJECT IDENTIFIER ::= { e1-card 1 }
-- userCurrentPerfTable OBJECT IDENTIFIER ::= { e1-card 2 }
-- userIntervalPerfTable OBJECT IDENTIFIER ::= { e1-card 3 }
-- userTotalPerfTable OBJECT IDENTIFIER ::= { e1-card 4 }
-- userSevenDayPerfTable OBJECT IDENTIFIER ::= { e1-card 5 }
-- remoteCurrentPerfTable OBJECT IDENTIFIER ::= { e1-card 6 }
-- remoteIntervalPerfTable OBJECT IDENTIFIER ::= { e1-card 7 }
-- remoteTotalPerfTable OBJECT IDENTIFIER ::= { e1-card 8 }
-- remoteSevenDayPerfTable OBJECT IDENTIFIER ::= { e1-card 9 }
-- lineCurrentPerfTable OBJECT IDENTIFIER ::= { e1-card 10 }
-- lineIntervalPerfTable OBJECT IDENTIFIER ::= { e1-card 11 }
-- lineTotalPerfTable OBJECT IDENTIFIER ::= { e1-card 12 }
-- lineSevenDayPerfTable OBJECT IDENTIFIER ::= { e1-card 13 }
-- alarmQueueTable OBJECT IDENTIFIER ::= { e1-card 14 }
-- alarmHistoryTable OBJECT IDENTIFIER ::= { e1-card 15 }
-- lineAvailabilityTable OBJECT IDENTIFIER ::= { e1-card 16 }
-- alarmControlTable OBJECT IDENTIFIER ::= { e1-card 17 }
-- thresholdControlTable OBJECT IDENTIFIER ::= { e1-card 18 }
-- lineDiagControlTable OBJECT IDENTIFIER ::= { e1-card 19 }
-- commandControlTable OBJECT IDENTIFIER ::= { e1-card 20 }
-- systemInformationTable OBJECT IDENTIFIER ::= { e1-card 21 }
--======================================================================--
--
-- Line Control Table
--
e1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { e1-card 1 }
e1LineControlEntry OBJECT-TYPE
SYNTAX E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { e1Index }
::= { e1LineControlTable 1 }
E1LineControlEntry ::= SEQUENCE {
e1Index SmallSlotIndex,
e1LineFrame INTEGER,
e1LineCoding INTEGER,
e1Interface INTEGER,
e1FDL INTEGER,
e1FDLSabit INTEGER,
e1AIS INTEGER,
e1RAI INTEGER,
e1CRC INTEGER,
e1IdleCode INTEGER,
e1CASMode INTEGER,
e1SignallingMode INTEGER,
e1CGA INTEGER,
e1OutOfService INTEGER
}
e1Index OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { e1LineControlEntry 1 }
e1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { e1LineControlEntry 2 }
e1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { e1LineControlEntry 3 }
e1Interface OBJECT-TYPE
SYNTAX INTEGER {
twisted-pair(1),
coaxial-cable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that E1 line use 75/120 Ohm Cable."
::= { e1LineControlEntry 4 }
e1FDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link ON/OFF"
::= { e1LineControlEntry 5 }
e1FDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5)
-- sa4-5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link use Sax bit"
::= { e1LineControlEntry 6 }
e1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 line Alarm Indication Signal."
::= { e1LineControlEntry 7 }
e1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { e1LineControlEntry 8 }
e1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Cycle Redundancy Check ON/OFF"
::= { e1LineControlEntry 9 }
e1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { e1LineControlEntry 10 }
e1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { e1LineControlEntry 11 }
e1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
cd01(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS or CD01"
::= { e1LineControlEntry 12 }
e1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1),
trans(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { e1LineControlEntry 13 }
e1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2)
-- busy-idle(3),
-- idle-busy(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { e1LineControlEntry 14 }
--
-- User Current Performance Table
--
e1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { e1-card 2 }
e1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX E1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { e1Index }
::= { e1UserCurrentPerfTable 1 }
E1UserCurrentPerfEntry ::= SEQUENCE {
e1UserCurrentPerfES INTEGER,
e1UserCurrentPerfSES INTEGER,
e1UserCurrentPerfBES INTEGER,
e1UserCurrentPerfUAS INTEGER,
e1UserCurrentPerfCSS INTEGER,
e1UserCurrentPerfBPV INTEGER,
e1UserCurrentPerfDMs INTEGER,
e1UserCurr15MinTimeElapsed INTEGER,
e1UserValid15MinInterval INTEGER
}
e1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1UserCurrentPerfEntry 2 }
e1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1UserCurrentPerfEntry 3 }
e1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1UserCurrentPerfEntry 4 }
e1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1UserCurrentPerfEntry 5 }
e1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { e1UserCurrentPerfEntry 6 }
e1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1UserCurrentPerfEntry 7 }
e1UserCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1UserCurrentPerfEntry 8 }
e1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { e1UserCurrentPerfEntry 11 }
e1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { e1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
e1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { e1-card 3 }
e1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX E1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { e1Index ,
e1UserIntervalPerfNumber }
::= { e1UserIntervalPerfTable 1 }
E1UserIntervalPerfEntry ::= SEQUENCE {
e1UserIntervalPerfNumber INTEGER (1..96),
e1UserIntervalPerfES INTEGER,
e1UserIntervalPerfSES INTEGER,
e1UserIntervalPerfBES INTEGER,
e1UserIntervalPerfUAS INTEGER,
e1UserIntervalPerfCSS INTEGER,
e1UserIntervalPerfBPV INTEGER,
e1UserIntervalPerfDMs INTEGER
}
e1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { e1UserIntervalPerfEntry 2 }
e1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1UserIntervalPerfEntry 3 }
e1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1UserIntervalPerfEntry 4 }
e1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1UserIntervalPerfEntry 5 }
e1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1UserIntervalPerfEntry 6 }
e1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1UserIntervalPerfEntry 7 }
e1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1UserIntervalPerfEntry 8 }
e1UserIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
e1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { e1-card 4 }
e1UserTotalPerfEntry OBJECT-TYPE
SYNTAX E1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { e1Index }
::= { e1UserTotalPerfTable 1 }
E1UserTotalPerfEntry ::= SEQUENCE {
e1UserTotalPerfES INTEGER,
e1UserTotalPerfSES INTEGER,
e1UserTotalPerfBES INTEGER,
e1UserTotalPerfUAS INTEGER,
e1UserTotalPerfCSS INTEGER,
e1UserTotalPerfBPV INTEGER,
e1UserTotalPerfDMs INTEGER
}
e1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1UserTotalPerfEntry 2 }
e1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1UserTotalPerfEntry 3 }
e1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1UserTotalPerfEntry 4 }
e1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1UserTotalPerfEntry 5 }
e1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1UserTotalPerfEntry 6 }
e1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1UserTotalPerfEntry 7 }
e1UserTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
e1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { e1-card 5 }
e1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX E1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { e1Index ,
e1UserDaysIndex }
::= { e1UserSevenDaysPerfTable 1 }
E1UserSevenDaysPerfEntry ::= SEQUENCE {
e1UserDaysIndex INTEGER (1..7),
e1UserDateStrIndex DisplayString (SIZE (0..255) ),
e1UserSevenDaysPerfES INTEGER,
e1UserSevenDaysPerfSES INTEGER,
e1UserSevenDaysPerfBES INTEGER,
e1UserSevenDaysPerfUAS INTEGER,
e1UserSevenDaysPerfCSS INTEGER,
e1UserSevenDaysPerfDMs INTEGER
}
e1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { e1UserSevenDaysPerfEntry 2 }
e1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { e1UserSevenDaysPerfEntry 3 }
e1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1UserSevenDaysPerfEntry 4 }
e1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1UserSevenDaysPerfEntry 5 }
e1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1UserSevenDaysPerfEntry 6 }
e1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1UserSevenDaysPerfEntry 7 }
e1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1UserSevenDaysPerfEntry 8 }
e1UserSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1UserSevenDaysPerfEntry 9 }
--
-- Line Current Performance Table
--
e1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { e1-card 10 }
e1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX E1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { e1Index }
::= { e1LineCurrentPerfTable 1 }
E1LineCurrentPerfEntry ::= SEQUENCE {
e1LineCurrentPerfES INTEGER,
e1LineCurrentPerfSES INTEGER,
e1LineCurrentPerfBES INTEGER,
e1LineCurrentPerfUAS INTEGER,
e1LineCurrentPerfCSS INTEGER,
e1LineCurrentPerfBPV INTEGER,
e1LineCurrentPerfDMs INTEGER,
e1LineCurr15MinTimeElapsed INTEGER,
e1LineValid15MinInterval INTEGER
}
e1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { e1LineCurrentPerfEntry 2 }
e1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1LineCurrentPerfEntry 3 }
e1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1LineCurrentPerfEntry 4 }
e1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1LineCurrentPerfEntry 5 }
e1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1LineCurrentPerfEntry 6 }
e1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1LineCurrentPerfEntry 7 }
e1LineCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1LineCurrentPerfEntry 8 }
e1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { e1LineCurrentPerfEntry 11 }
e1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { e1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
e1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { e1-card 11 }
e1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX E1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { e1Index ,
e1LineIntervalPerfNumber }
::= { e1LineIntervalPerfTable 1 }
E1LineIntervalPerfEntry ::= SEQUENCE {
e1LineIntervalPerfNumber INTEGER (1..96),
e1LineIntervalPerfES INTEGER,
e1LineIntervalPerfSES INTEGER,
e1LineIntervalPerfBES INTEGER,
e1LineIntervalPerfUAS INTEGER,
e1LineIntervalPerfCSS INTEGER,
e1LineIntervalPerfBPV INTEGER,
e1LineIntervalPerfDMs INTEGER,
e1LineIntvAvailable INTEGER
}
e1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { e1LineIntervalPerfEntry 2 }
e1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1LineIntervalPerfEntry 3 }
e1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1LineIntervalPerfEntry 4 }
e1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1LineIntervalPerfEntry 5 }
e1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1LineIntervalPerfEntry 6 }
e1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1LineIntervalPerfEntry 7 }
e1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1LineIntervalPerfEntry 8 }
e1LineIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1LineIntervalPerfEntry 9 }
e1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { e1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
e1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { e1-card 12 }
e1LineTotalPerfEntry OBJECT-TYPE
SYNTAX E1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { e1Index }
::= { e1LineTotalPerfTable 1 }
E1LineTotalPerfEntry ::= SEQUENCE {
e1LineTotalPerfES INTEGER,
e1LineTotalPerfSES INTEGER,
e1LineTotalPerfBES INTEGER,
e1LineTotalPerfUAS INTEGER,
e1LineTotalPerfCSS INTEGER,
e1LineTotalPerfBPV INTEGER,
e1LineTotalPerfDMs INTEGER
}
e1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1LineTotalPerfEntry 2 }
e1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1LineTotalPerfEntry 3 }
e1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1LineTotalPerfEntry 4 }
e1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1LineTotalPerfEntry 5 }
e1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1LineTotalPerfEntry 6 }
e1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { e1LineTotalPerfEntry 7 }
e1LineTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
e1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { e1-card 13 }
e1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX E1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { e1Index ,
e1LineDaysIndex }
::= { e1LineSevenDaysPerfTable 1 }
E1LineSevenDaysPerfEntry ::= SEQUENCE {
e1LineDaysIndex INTEGER (1..7),
e1LineDateStrIndex DisplayString (SIZE (0..255) ),
e1LineSevenDaysPerfES INTEGER,
e1LineSevenDaysPerfSES INTEGER,
e1LineSevenDaysPerfBES INTEGER,
e1LineSevenDaysPerfUAS INTEGER,
e1LineSevenDaysPerfCSS INTEGER,
e1LineSevenDaysPerfDMs INTEGER
}
e1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { e1LineSevenDaysPerfEntry 2 }
e1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { e1LineSevenDaysPerfEntry 3 }
e1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { e1LineSevenDaysPerfEntry 4 }
e1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { e1LineSevenDaysPerfEntry 5 }
e1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { e1LineSevenDaysPerfEntry 6 }
e1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { e1LineSevenDaysPerfEntry 7 }
e1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { e1LineSevenDaysPerfEntry 8 }
e1LineSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { e1LineSevenDaysPerfEntry 9 }
--
-- Alarm Queue Table
--
e1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { e1-card 14 }
e1AlarmQueueEntry OBJECT-TYPE
SYNTAX E1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { e1Index ,
e1AlarmQueueIndex }
::= { e1AlarmQueueTable 1 }
E1AlarmQueueEntry ::= SEQUENCE {
e1AlarmQueueIndex INTEGER (1..40),
e1AlarmQueueString DisplayString (SIZE(0..255))
}
e1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { e1AlarmQueueEntry 2 }
e1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { e1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
e1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { e1-card 15 }
e1AlarmHistoryEntry OBJECT-TYPE
SYNTAX E1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { e1Index ,
e1AlarmHistoryIndex }
::= { e1AlarmHistoryTable 1 }
E1AlarmHistoryEntry ::= SEQUENCE {
e1AlarmHistoryIndex INTEGER,
e1Threshold INTEGER,
e1CurrentState INTEGER,
e1CurrentCount INTEGER,
e1Alarm AlarmSeverity
}
e1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { e1AlarmHistoryEntry 2 }
e1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { e1AlarmHistoryEntry 3 }
e1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { e1AlarmHistoryEntry 4 }
e1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { e1AlarmHistoryEntry 5 }
e1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { e1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
e1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { e1-card 16 }
e1LineAvailabilityEntry OBJECT-TYPE
SYNTAX E1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { e1Index }
::= { e1LineAvailabilityTable 1 }
E1LineAvailabilityEntry ::= SEQUENCE {
e1AvailableSeconds DisplayString,
e1UnavailableSeconds DisplayString,
e1LineAvailability DisplayString
}
e1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { e1LineAvailabilityEntry 2 }
e1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { e1LineAvailabilityEntry 3 }
e1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { e1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
e1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { e1-card 17 }
e1AlarmControlEntry OBJECT-TYPE
SYNTAX E1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { e1Index }
::= { e1AlarmControlTable 1 }
E1AlarmControlEntry ::= SEQUENCE {
e1RAI-Line AlarmSeverity,
e1AIS-Line AlarmSeverity,
e1LOS-Line AlarmSeverity,
e1LOF-Line AlarmSeverity,
e1BPV-Line AlarmSeverity,
e1ESS-Line AlarmSeverity,
e1UAS-Line AlarmSeverity,
e1CSS-Line AlarmSeverity
}
e1RAI-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { e1AlarmControlEntry 2 }
e1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { e1AlarmControlEntry 3 }
e1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { e1AlarmControlEntry 4 }
e1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { e1AlarmControlEntry 5 }
e1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { e1AlarmControlEntry 6 }
e1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { e1AlarmControlEntry 7 }
e1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { e1AlarmControlEntry 8 }
e1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { e1AlarmControlEntry 9 }
--
-- Threshold Control Table
--
e1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { e1-card 18 }
e1ThresholdControlEntry OBJECT-TYPE
SYNTAX E1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { e1Index }
::= { e1ThresholdControlTable 1 }
E1ThresholdControlEntry ::= SEQUENCE {
e1ThresholdBPV-Line INTEGER,
e1ThresholdESS-Line INTEGER,
e1ThresholdUAS-Line INTEGER,
e1ThresholdCSS-Line INTEGER
}
e1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line "
::= { e1ThresholdControlEntry 2 }
e1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { e1ThresholdControlEntry 3 }
e1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { e1ThresholdControlEntry 4 }
e1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { e1ThresholdControlEntry 5 }
--
-- Line Diagnostic Control Table
--
e1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { e1-card 19 }
e1LineDiagControlEntry OBJECT-TYPE
SYNTAX E1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { e1Index }
::= { e1LineDiagControlTable 1 }
E1LineDiagControlEntry ::= SEQUENCE {
e1LoopbackType INTEGER,
e1LoopbackStatus INTEGER,
e1PRBSControl INTEGER,
e1PRBSStatus INTEGER,
e1PRBSElapseSeconds INTEGER,
e1PRBSErrorSeconds INTEGER,
e1PRBSErrorCounts INTEGER,
e1InbandLoopbackPeriod INTEGER
}
e1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-PLB-Active(5),
remote-LLB-Active(6),
remote-PLB-Deactive(7),
remote-LLB-Deactive(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"e1 Loopback Type"
::= { e1LineDiagControlEntry 2 }
e1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"e1 Loopback Status"
::= { e1LineDiagControlEntry 3 }
e1PRBSControl OBJECT-TYPE
SYNTAX INTEGER {
prbs-deactive(1),
prbs-active-full(2),
prbs-reset-error-count(3),
prbs-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"e1 PRBS Control"
::= { e1LineDiagControlEntry 4 }
e1PRBSStatus OBJECT-TYPE
SYNTAX INTEGER {
prbs-sync(1),
prbs-unsync(2),
prbs-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"e1 PRBS Status"
::= { e1LineDiagControlEntry 5 }
e1PRBSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"e1 PRBS Elapse Seconds"
::= { e1LineDiagControlEntry 6 }
e1PRBSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"e1 PRBS Error Seconds"
::= { e1LineDiagControlEntry 7 }
e1PRBSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"e1 PRBS Error Counts"
::= { e1LineDiagControlEntry 8 }
e1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of E1 inband local, payload, or line loopback"
::= { e1LineDiagControlEntry 9 }
--
-- Command Control Table
--
e1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { e1-card 20 }
e1CommandControlEntry OBJECT-TYPE
SYNTAX E1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { e1Index }
::= { e1CommandControlTable 1 }
E1CommandControlEntry ::= SEQUENCE {
e1AlarmQueueReset INTEGER,
e1UserPerfReset INTEGER,
e1AlarmHistoryReset INTEGER,
e1PortReset INTEGER,
e1PortLoadDefault INTEGER
}
e1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { e1CommandControlEntry 2 }
e1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { e1CommandControlEntry 3 }
e1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { e1CommandControlEntry 4 }
e1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset E1 Port"
::= { e1CommandControlEntry 5 }
e1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default E1 Port"
::= { e1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
e1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { e1-card 21 }
e1SystemInformationEntry OBJECT-TYPE
SYNTAX E1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { e1Index }
::= { e1SystemInformationTable 1 }
E1SystemInformationEntry ::= SEQUENCE {
e1PROMVersion DisplayString,
e1HWVersion DisplayString
}
e1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" e1 PROM Version"
::= { e1SystemInformationEntry 2 }
e1HWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" e1 HW Version"
::= { e1SystemInformationEntry 3 }
--
-- Remote Link Identification Table
--
e1RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification Table"
::= { e1-card 22 }
e1RemoteLinkIDEntry OBJECT-TYPE
SYNTAX E1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification entry"
INDEX { e1Index }
::= { e1RemoteLinkIDTable 1 }
E1RemoteLinkIDEntry ::= SEQUENCE {
e1RemoteLinkIDType INTEGER,
e1RemoteLinkIDRack INTEGER,
e1RemoteLinkIDSlotNumber INTEGER,
e1RemoteLinkIDPort INTEGER,
e1RemoteLinkIDSerialNumber INTEGER,
e1RemoteLinkIDBackupSlotNUM INTEGER,
e1RemoteLinkIDBackupPort INTEGER
}
e1RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of remote site."
::= { e1RemoteLinkIDEntry 2 }
e1RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { e1RemoteLinkIDEntry 3 }
e1RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { e1RemoteLinkIDEntry 4 }
e1RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { e1RemoteLinkIDEntry 5 }
e1RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { e1RemoteLinkIDEntry 6 }
e1RemoteLinkIDBackupSlotNUM OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Slot Number"
::= { e1RemoteLinkIDEntry 7 }
e1RemoteLinkIDBackupPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Port"
::= { e1RemoteLinkIDEntry 8 }
--
-- E1 Customer Information Table
--
e1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF E1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { e1-card 99 }
e1CustomerInfoEntry OBJECT-TYPE
SYNTAX E1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { e1CISlotIndex , e1CIPortIndex }
::= { e1CustomerInfoTable 1 }
E1CustomerInfoEntry ::= SEQUENCE {
e1CISlotIndex SmallSlotIndex,
e1CIPortIndex FourPortID,
e1CICustomerInfo DisplayString (SIZE(0..64))
}
e1CISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { e1CustomerInfoEntry 1 }
e1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { e1CustomerInfoEntry 2 }
e1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { e1CustomerInfoEntry 3 }
e1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of FE1"
::= { e1-card 100 }
--======================================================================--
--======================================================================--
-- t1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
t1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { t1-card 1 }
t1LineControlEntry OBJECT-TYPE
SYNTAX T1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { t1Index }
::= { t1LineControlTable 1 }
T1LineControlEntry ::= SEQUENCE {
t1Index SmallSlotIndex,
t1LineFrame INTEGER,
t1LineCoding INTEGER,
t1Interface INTEGER,
t1LineBuildOut INTEGER,
t1Equalizer INTEGER,
t1AIS INTEGER,
t1YEL INTEGER,
t1Inband INTEGER,
t1IdleCode INTEGER,
t1CASMode INTEGER,
t1SignallingMode INTEGER,
t1CGA INTEGER,
t1OutOfService INTEGER
}
t1Index OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { t1LineControlEntry 1 }
t1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esf-t1-403(3),
g802(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { t1LineControlEntry 2 }
t1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { t1LineControlEntry 3 }
t1Interface OBJECT-TYPE
SYNTAX INTEGER {
long-haul(1),
short-haul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that T1 line use Long/Short haul."
::= { t1LineControlEntry 4 }
t1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo-0-0dB(1),
lbo-7-5dB(2),
lbo-15dB(3)
-- lbo-0.0dB(1),
-- lbo-7.5dB(2),
-- lbo-15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line build out."
::= { t1LineControlEntry 5 }
t1Equalizer OBJECT-TYPE
SYNTAX INTEGER {
equ-0-133Ft(1),
equ-133-266ft(2),
equ-266-399ft(3),
equ-399-533ft(4),
equ-533-655ft(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line equalizer."
::= { t1LineControlEntry 6 }
t1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line Alarm Indication Signal."
::= { t1LineControlEntry 7 }
t1YEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { t1LineControlEntry 8 }
t1Inband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line inband ON/OFF"
::= { t1LineControlEntry 9 }
t1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { t1LineControlEntry 10 }
t1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { t1LineControlEntry 11 }
t1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS"
::= { t1LineControlEntry 12 }
t1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
-- trans(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { t1LineControlEntry 13 }
t1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2)
-- busy-idle(3),
-- idle-busy(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { t1LineControlEntry 14 }
--
-- User Current Performance Table
--
t1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { t1-card 2 }
t1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX T1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { t1Index }
::= { t1UserCurrentPerfTable 1 }
T1UserCurrentPerfEntry ::= SEQUENCE {
t1UserCurrentPerfES INTEGER,
t1UserCurrentPerfSES INTEGER,
t1UserCurrentPerfBES INTEGER,
t1UserCurrentPerfUAS INTEGER,
t1UserCurrentPerfCSS INTEGER,
t1UserCurrentPerfBPV INTEGER,
t1UserCurrentPerfLOFC INTEGER,
t1UserCurr15MinTimeElapsed INTEGER,
t1UserValid15MinInterval INTEGER
}
t1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1UserCurrentPerfEntry 2 }
t1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1UserCurrentPerfEntry 3 }
t1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1UserCurrentPerfEntry 4 }
t1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1UserCurrentPerfEntry 5 }
t1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { t1UserCurrentPerfEntry 6 }
t1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1UserCurrentPerfEntry 7 }
t1UserCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1UserCurrentPerfEntry 8 }
t1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { t1UserCurrentPerfEntry 11 }
t1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { t1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
t1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { t1-card 3 }
t1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX T1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { t1Index ,
t1UserIntervalPerfNumber }
::= { t1UserIntervalPerfTable 1 }
T1UserIntervalPerfEntry ::= SEQUENCE {
t1UserIntervalPerfNumber INTEGER (1..96),
t1UserIntervalPerfES INTEGER,
t1UserIntervalPerfSES INTEGER,
t1UserIntervalPerfBES INTEGER,
t1UserIntervalPerfUAS INTEGER,
t1UserIntervalPerfCSS INTEGER,
t1UserIntervalPerfBPV INTEGER,
t1UserIntervalPerfLOFC INTEGER
}
t1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { t1UserIntervalPerfEntry 2 }
t1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1UserIntervalPerfEntry 3 }
t1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1UserIntervalPerfEntry 4 }
t1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1UserIntervalPerfEntry 5 }
t1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1UserIntervalPerfEntry 6 }
t1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1UserIntervalPerfEntry 7 }
t1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1UserIntervalPerfEntry 8 }
t1UserIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
t1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { t1-card 4 }
t1UserTotalPerfEntry OBJECT-TYPE
SYNTAX T1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { t1Index }
::= { t1UserTotalPerfTable 1 }
T1UserTotalPerfEntry ::= SEQUENCE {
t1UserTotalPerfES INTEGER,
t1UserTotalPerfSES INTEGER,
t1UserTotalPerfBES INTEGER,
t1UserTotalPerfUAS INTEGER,
t1UserTotalPerfCSS INTEGER,
t1UserTotalPerfBPV INTEGER,
t1UserTotalPerfLOFC INTEGER
}
t1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1UserTotalPerfEntry 2 }
t1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1UserTotalPerfEntry 3 }
t1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1UserTotalPerfEntry 4 }
t1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1UserTotalPerfEntry 5 }
t1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1UserTotalPerfEntry 6 }
t1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1UserTotalPerfEntry 7 }
t1UserTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
t1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { t1-card 22 }
t1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX T1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance entry"
INDEX { t1Index ,
t1UserDaysIndex }
::= { t1UserSevenDaysPerfTable 1 }
T1UserSevenDaysPerfEntry ::= SEQUENCE {
t1UserDaysIndex INTEGER (1..7),
t1UserDateStrIndex DisplayString (SIZE (0..255) ),
t1UserSevenDaysPerfES INTEGER,
t1UserSevenDaysPerfSES INTEGER,
t1UserSevenDaysPerfBES INTEGER,
t1UserSevenDaysPerfUAS INTEGER,
t1UserSevenDaysPerfCSS INTEGER
-- t1UserSevenDaysPerfLOFC INTEGER
}
t1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { t1UserSevenDaysPerfEntry 2 }
t1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { t1UserSevenDaysPerfEntry 3 }
t1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1UserSevenDaysPerfEntry 4 }
t1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1UserSevenDaysPerfEntry 5 }
t1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1UserSevenDaysPerfEntry 6 }
t1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1UserSevenDaysPerfEntry 7 }
t1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1UserSevenDaysPerfEntry 8 }
-- t1UserSevenDaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { t1UserSevenDaysPerfEntry 9 }
--
-- Line Current Performance Table
--
t1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { t1-card 8 }
t1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX T1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { t1Index }
::= { t1LineCurrentPerfTable 1 }
T1LineCurrentPerfEntry ::= SEQUENCE {
t1LineCurrentPerfES INTEGER,
t1LineCurrentPerfSES INTEGER,
t1LineCurrentPerfBES INTEGER,
t1LineCurrentPerfUAS INTEGER,
t1LineCurrentPerfCSS INTEGER,
t1LineCurrentPerfBPV INTEGER,
t1LineCurrentPerfLOFC INTEGER,
t1LineCurr15MinTimeElapsed INTEGER,
t1LineValid15MinInterval INTEGER
}
t1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { t1LineCurrentPerfEntry 2 }
t1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1LineCurrentPerfEntry 3 }
t1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1LineCurrentPerfEntry 4 }
t1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1LineCurrentPerfEntry 5 }
t1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1LineCurrentPerfEntry 6 }
t1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1LineCurrentPerfEntry 7 }
t1LineCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1LineCurrentPerfEntry 8 }
t1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { t1LineCurrentPerfEntry 11 }
t1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { t1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
t1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { t1-card 9 }
t1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX T1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { t1Index ,
t1LineIntervalPerfNumber }
::= { t1LineIntervalPerfTable 1 }
T1LineIntervalPerfEntry ::= SEQUENCE {
t1LineIntervalPerfNumber INTEGER (1..96),
t1LineIntervalPerfES INTEGER,
t1LineIntervalPerfSES INTEGER,
t1LineIntervalPerfBES INTEGER,
t1LineIntervalPerfUAS INTEGER,
t1LineIntervalPerfCSS INTEGER,
t1LineIntervalPerfBPV INTEGER,
t1LineIntervalPerfLOFC INTEGER,
t1LineIntvAvailable INTEGER
}
t1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index "
::= { t1LineIntervalPerfEntry 2 }
t1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1LineIntervalPerfEntry 3 }
t1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1LineIntervalPerfEntry 4 }
t1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1LineIntervalPerfEntry 5 }
t1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1LineIntervalPerfEntry 6 }
t1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1LineIntervalPerfEntry 7 }
t1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1LineIntervalPerfEntry 8 }
t1LineIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1LineIntervalPerfEntry 9 }
t1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { t1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
t1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { t1-card 10 }
t1LineTotalPerfEntry OBJECT-TYPE
SYNTAX T1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance entry"
INDEX { t1Index }
::= { t1LineTotalPerfTable 1 }
T1LineTotalPerfEntry ::= SEQUENCE {
t1LineTotalPerfES INTEGER,
t1LineTotalPerfSES INTEGER,
t1LineTotalPerfBES INTEGER,
t1LineTotalPerfUAS INTEGER,
t1LineTotalPerfCSS INTEGER,
t1LineTotalPerfBPV INTEGER,
t1LineTotalPerfLOFC INTEGER
}
t1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1LineTotalPerfEntry 2 }
t1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1LineTotalPerfEntry 3 }
t1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1LineTotalPerfEntry 4 }
t1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1LineTotalPerfEntry 5 }
t1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1LineTotalPerfEntry 6 }
t1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { t1LineTotalPerfEntry 7 }
t1LineTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { t1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
t1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { t1-card 21 }
t1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX T1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { t1Index ,
t1LineDaysIndex }
::= { t1LineSevenDaysPerfTable 1 }
T1LineSevenDaysPerfEntry ::= SEQUENCE {
t1LineDaysIndex INTEGER (1..7),
t1LineDateStrIndex DisplayString (SIZE (0..255) ),
t1LineSevenDaysPerfES INTEGER,
t1LineSevenDaysPerfSES INTEGER,
t1LineSevenDaysPerfBES INTEGER,
t1LineSevenDaysPerfUAS INTEGER,
t1LineSevenDaysPerfCSS INTEGER
-- t1LineSevenDaysPerfLOFC INTEGER
}
t1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { t1LineSevenDaysPerfEntry 2 }
t1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { t1LineSevenDaysPerfEntry 3 }
t1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { t1LineSevenDaysPerfEntry 4 }
t1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { t1LineSevenDaysPerfEntry 5 }
t1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { t1LineSevenDaysPerfEntry 6 }
t1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { t1LineSevenDaysPerfEntry 7 }
t1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { t1LineSevenDaysPerfEntry 8 }
-- t1LineSevenDaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { t1LineSevenDaysPerfEntry 9 }
--
-- Alarm Queue Table
--
t1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Queue Table"
::= { t1-card 11 }
t1AlarmQueueEntry OBJECT-TYPE
SYNTAX T1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { t1Index ,
t1AlarmQueueIndex }
::= { t1AlarmQueueTable 1 }
T1AlarmQueueEntry ::= SEQUENCE {
t1AlarmQueueIndex INTEGER (1..40),
t1AlarmQueueString DisplayString (SIZE(0..255))
}
t1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { t1AlarmQueueEntry 2 }
t1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { t1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
t1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { t1-card 12 }
t1AlarmHistoryEntry OBJECT-TYPE
SYNTAX T1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { t1Index ,
t1AlarmHistoryIndex }
::= { t1AlarmHistoryTable 1 }
T1AlarmHistoryEntry ::= SEQUENCE {
t1AlarmHistoryIndex INTEGER,
t1Threshold INTEGER,
t1CurrentState INTEGER,
t1CurrentCount INTEGER,
t1Alarm AlarmSeverity
}
t1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
yel-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { t1AlarmHistoryEntry 2 }
t1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { t1AlarmHistoryEntry 3 }
t1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { t1AlarmHistoryEntry 4 }
t1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { t1AlarmHistoryEntry 5 }
t1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { t1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
t1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { t1-card 13 }
t1LineAvailabilityEntry OBJECT-TYPE
SYNTAX T1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { t1Index }
::= { t1LineAvailabilityTable 1 }
T1LineAvailabilityEntry ::= SEQUENCE {
t1AvailableSeconds DisplayString,
t1UnavailableSeconds DisplayString,
t1LineAvailability DisplayString
}
t1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { t1LineAvailabilityEntry 2 }
t1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { t1LineAvailabilityEntry 3 }
t1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { t1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
t1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { t1-card 14 }
t1AlarmControlEntry OBJECT-TYPE
SYNTAX T1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { t1Index }
::= { t1AlarmControlTable 1 }
T1AlarmControlEntry ::= SEQUENCE {
t1YEL-Line AlarmSeverity,
t1AIS-Line AlarmSeverity,
t1LOS-Line AlarmSeverity,
t1LOF-Line AlarmSeverity,
t1BPV-Line AlarmSeverity,
t1ESS-Line AlarmSeverity,
t1UAS-Line AlarmSeverity,
t1CSS-Line AlarmSeverity
}
t1YEL-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-Line State"
::= { t1AlarmControlEntry 2 }
t1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { t1AlarmControlEntry 3 }
t1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { t1AlarmControlEntry 4 }
t1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { t1AlarmControlEntry 5 }
t1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { t1AlarmControlEntry 6 }
t1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { t1AlarmControlEntry 7 }
t1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { t1AlarmControlEntry 8 }
t1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { t1AlarmControlEntry 9 }
--
-- Threshold Control Table
--
t1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { t1-card 15 }
t1ThresholdControlEntry OBJECT-TYPE
SYNTAX T1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { t1Index }
::= { t1ThresholdControlTable 1 }
T1ThresholdControlEntry ::= SEQUENCE {
t1ThresholdBPV-Line INTEGER,
t1ThresholdESS-Line INTEGER,
t1ThresholdUAS-Line INTEGER,
t1ThresholdCSS-Line INTEGER
}
t1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line "
::= { t1ThresholdControlEntry 2 }
t1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { t1ThresholdControlEntry 3 }
t1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { t1ThresholdControlEntry 4 }
t1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { t1ThresholdControlEntry 5 }
--
-- Line Diagnostic Control Table
--
t1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { t1-card 16 }
t1LineDiagControlEntry OBJECT-TYPE
SYNTAX T1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { t1Index }
::= { t1LineDiagControlTable 1 }
T1LineDiagControlEntry ::= SEQUENCE {
t1LoopbackType INTEGER,
t1LoopbackStatus INTEGER,
t1QRSSControl INTEGER,
t1QRSSStatus INTEGER,
t1QRSSElapseSeconds INTEGER,
t1QRSSErrorSeconds INTEGER,
t1QRSSErrorCounts INTEGER,
t1InbandLoopbackPeriod INTEGER
}
t1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-LLB-Inband-Active(5),
remote-PLB-ATT-Active(6),
remote-PLB-ANSI-Active(7),
remote-LLB-ANSI-Active(8),
remote-LLB-Inband-Deactive(9),
remote-PLB-ATT-Deactive(10),
remote-PLB-ANSI-Deactive(11),
remote-LLB-ANSI-Deactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"t1 Loopback Type"
::= { t1LineDiagControlEntry 2 }
t1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"t1 Loopback Status"
::= { t1LineDiagControlEntry 3 }
t1QRSSControl OBJECT-TYPE
SYNTAX INTEGER {
qrss-deactive(1),
qrss-active-full(2),
qrss-reset-error-count(3),
qrss-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"t1 QRSS Control"
::= { t1LineDiagControlEntry 4 }
t1QRSSStatus OBJECT-TYPE
SYNTAX INTEGER {
qrss-sync(1),
qrss-unsync(2),
qrss-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"t1 QRSS Status"
::= { t1LineDiagControlEntry 5 }
t1QRSSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"t1 QRSS Elapse Seconds"
::= { t1LineDiagControlEntry 6 }
t1QRSSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"t1 QRSS Error Seconds"
::= { t1LineDiagControlEntry 7 }
t1QRSSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"t1 QRSS Error Counts"
::= { t1LineDiagControlEntry 8 }
t1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of T1 inband local, payload, or line loopback"
::= { t1LineDiagControlEntry 9 }
--
-- Command Control Table
--
t1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { t1-card 17 }
t1CommandControlEntry OBJECT-TYPE
SYNTAX T1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { t1Index }
::= { t1CommandControlTable 1 }
T1CommandControlEntry ::= SEQUENCE {
t1AlarmQueueReset INTEGER,
t1UserPerfReset INTEGER,
t1AlarmHistoryReset INTEGER,
t1PortReset INTEGER,
t1PortLoadDefault INTEGER
}
t1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { t1CommandControlEntry 2 }
t1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { t1CommandControlEntry 3 }
t1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { t1CommandControlEntry 4 }
t1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset T1 Port"
::= { t1CommandControlEntry 5 }
t1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default T1 Port"
::= { t1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
t1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { t1-card 18 }
t1SystemInformationEntry OBJECT-TYPE
SYNTAX T1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { t1Index }
::= { t1SystemInformationTable 1 }
T1SystemInformationEntry ::= SEQUENCE {
t1PROMVersion DisplayString,
t1HWVersion DisplayString
}
t1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" t1 PROM Version"
::= { t1SystemInformationEntry 2 }
t1HWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" t1 HW Version"
::= { t1SystemInformationEntry 3 }
--
-- T1 Customer Information Table
--
t1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { t1-card 99 }
t1CustomerInfoEntry OBJECT-TYPE
SYNTAX T1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { t1CISlotIndex , t1CIPortIndex }
::= { t1CustomerInfoTable 1 }
T1CustomerInfoEntry ::= SEQUENCE {
t1CISlotIndex SmallSlotIndex,
t1CIPortIndex FourPortID,
t1CICustomerInfo DisplayString (SIZE(0..64))
}
t1CISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { t1CustomerInfoEntry 1 }
t1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { t1CustomerInfoEntry 2 }
t1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { t1CustomerInfoEntry 3 }
t1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of FT1"
::= { t1-card 100 }
--======================================================================--
--======================================================================--
-- dtu-card MIB
--======================================================================--
--======================================================================--
--
-- DTU Command Control Table
--
dtuCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU command control table."
::= { dtu-card 1 }
dtuCommandControlEntry OBJECT-TYPE
SYNTAX DtuCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU command control table."
INDEX { dtuCommandSlotIndex , dtuCommandPortIndex }
::= { dtuCommandControlTable 1 }
DtuCommandControlEntry ::= SEQUENCE {
dtuCommandSlotIndex LargeSlotIndex,
dtuCommandPortIndex TenPortID,
dtuClearPerformanceData INTEGER,
dtuPortReset INTEGER,
dtuPortClearCRC INTEGER,
dtuCardReset INTEGER
}
dtuCommandSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuCommandControlEntry 1 }
dtuCommandPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-10"
::= { dtuCommandControlEntry 2 }
dtuClearPerformanceData OBJECT-TYPE
SYNTAX INTEGER {
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear DTU performance data"
::= { dtuCommandControlEntry 3 }
dtuPortReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTU port"
::= { dtuCommandControlEntry 4 }
dtuPortClearCRC OBJECT-TYPE
SYNTAX INTEGER {
clear-local-crc(1),
clear-remote-crc(2),
clear-all-port-crc(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear DTU port CRC Error Counter."
::= { dtuCommandControlEntry 5 }
dtuCardReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTU Card"
::= { dtuCommandControlEntry 6 }
--
-- Remote DTE Config Table
--
dtuRdteConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRdteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU remote DTE configuration."
::= { dtu-card 2 }
dtuRdteConfigEntry OBJECT-TYPE
SYNTAX DtuRdteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU remote DTE configuration."
INDEX { dtuRdteSlotIndex , dtuRdtePortIndex }
::= { dtuRdteConfigTable 1 }
DtuRdteConfigEntry ::= SEQUENCE {
dtuRdteSlotIndex LargeSlotIndex,
dtuRdtePortIndex TenPortID,
dtuSyncMode INTEGER,
dtuRdteSpeed INTEGER,
dtuRdteChannel INTEGER,
dtuRdteClock INTEGER,
dtuRdteData INTEGER,
dtuRdteRTS INTEGER,
dtuRdteTTM INTEGER,
dtuRdteInterface INTEGER,
dtuRdteX50IdleCode INTEGER,
dtuRdteX50Map DisplayString,
dtuRdteX50Status DisplayString
}
dtuRdteSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRdteConfigEntry 1 }
dtuRdtePortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-10"
::= { dtuRdteConfigEntry 2 }
dtuSyncMode OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
async(2),
async-8(3),
async-9(4),
async-10(5),
async-11(6),
n-a(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote SYNC mode"
::= { dtuRdteConfigEntry 3 }
dtuRdteSpeed OBJECT-TYPE
SYNTAX INTEGER {
nx64K(1),
nx56K(2),
nx128K(3),
nx112K(4),
nx0K(5),
nx1-2K(6),
nx2-4K(7),
nx4-8K(8),
nx9-6K(9),
nx19-2K(10),
nx38-4K(11),
nx48-0K(12),
-- async1-2K(13),
-- async2-4K(14),
-- async4-8K(15),
-- async9-6K(16),
-- async19-2K(17),
-- async38-4K(18),
n-a(13)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE Speed"
::= { dtuRdteConfigEntry 4 }
dtuRdteChannel OBJECT-TYPE
SYNTAX INTEGER {
iDLE(1),
b1(2),
b2(3),
b1-b2(4),
n-a(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE channel"
::= { dtuRdteConfigEntry 5 }
dtuRdteClock OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE clock type"
::= { dtuRdteConfigEntry 6 }
dtuRdteData OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE data type"
::= { dtuRdteConfigEntry 7 }
dtuRdteRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE RTS type"
::= { dtuRdteConfigEntry 8 }
dtuRdteTTM OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE TTM type"
::= { dtuRdteConfigEntry 9 }
dtuRdteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
rs449-eia530(2),
x21(3),
rs232(4),
rs232-SubRate(8),
g-703(11),
na(16),
other(18),
router(20),
rs232-x50(24)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote DTE card interface"
::= { dtuRdteConfigEntry 10 }
dtuRdteX50IdleCode OBJECT-TYPE
SYNTAX INTEGER (0..47)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 idle code"
::= { dtuRdteConfigEntry 11 }
dtuRdteX50Map OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..21) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 Map"
::= { dtuRdteConfigEntry 12 }
dtuRdteX50Status OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..21) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 Status"
::= { dtuRdteConfigEntry 13 }
--
-- Diagnostic Control Table
--
dtuDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU diagnostics control table."
::= { dtu-card 3 }
dtuDiagControlEntry OBJECT-TYPE
SYNTAX DtuDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU diagnostics control table."
INDEX { dtuDiagSlotIndex , dtuDiagPortIndex }
::= { dtuDiagControlTable 1 }
DtuDiagControlEntry ::= SEQUENCE {
dtuDiagSlotIndex LargeSlotIndex,
dtuDiagPortIndex TenPortID,
dtuNearLoopback INTEGER,
dtuRemoteLoopback INTEGER,
dtuBertControl INTEGER,
dtuBertStatus INTEGER,
dtuQrssElapseSeconds INTEGER,
dtuQrssErrorSeconds INTEGER,
dtuQrssErrorBits INTEGER,
dtuRemBertControl INTEGER,
dtuRemBertStatus INTEGER,
dtuRemQrssElapseSeconds INTEGER,
dtuRemQrssErrorSeconds INTEGER,
dtuRemQrssErrorBits INTEGER,
dtuRemQrssPatternUnsyncSeconds INTEGER
}
dtuDiagSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuDiagControlEntry 1 }
dtuDiagPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-10"
::= { dtuDiagControlEntry 2 }
dtuNearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payLoadLoopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Near loopback type"
::= { dtuDiagControlEntry 3 }
dtuRemoteLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
remotePayLoad(2),
remoteDTE-or-remoteROUTER(3),
remoteDTE-DTE(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote loopback type"
::= { dtuDiagControlEntry 4 }
dtuBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-ON(2),
reset(3),
inject-Error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT control"
::= { dtuDiagControlEntry 5 }
dtuBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-Sync(1),
bert-Unsync(2),
bert-Not-Active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { dtuDiagControlEntry 6 }
dtuQrssElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss elapse seconds"
::= { dtuDiagControlEntry 7 }
dtuQrssErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error seconds"
::= { dtuDiagControlEntry 8 }
dtuQrssErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error bits"
::= { dtuDiagControlEntry 9 }
dtuRemBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-FULL(2),
bert-DTE1(3),
-- bert-DTE2(4),
reset(5),
inject-Error(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT control"
::= { dtuDiagControlEntry 10 }
dtuRemBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-Sync(1),
bert-Unsync(2),
bert-Not-Active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { dtuDiagControlEntry 11 }
dtuRemQrssElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss elapse seconds"
::= { dtuDiagControlEntry 12 }
dtuRemQrssErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error seconds"
::= { dtuDiagControlEntry 13 }
dtuRemQrssErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error bits"
::= { dtuDiagControlEntry 14 }
dtuRemQrssPatternUnsyncSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss pattern unsync seconds"
::= { dtuDiagControlEntry 15 }
--
-- Alarm History Table
--
dtuAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The dtu alarm history table."
::= { dtu-card 4 }
dtuAlarmHistoryEntry OBJECT-TYPE
SYNTAX DtuAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU alarm history table."
INDEX { dtuAlmhisSlotIndex , dtuAlmhisPortIndex }
::= { dtuAlarmHistoryTable 1 }
DtuAlarmHistoryEntry ::= SEQUENCE {
dtuAlmhisSlotIndex LargeSlotIndex,
dtuAlmhisPortIndex TenPortID,
dtuUnsyncAlarmState INTEGER,
dtuUnsyncAlarmCount INTEGER
}
dtuAlmhisSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuAlarmHistoryEntry 1 }
dtuAlmhisPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuAlarmHistoryEntry 2 }
dtuUnsyncAlarmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm history : unsync alarm state"
::= { dtuAlarmHistoryEntry 3 }
dtuUnsyncAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm history : unsync alarm count"
::= { dtuAlarmHistoryEntry 4 }
--
-- Alarm Control Table
--
dtuAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU alarm control table."
::= { dtu-card 5 }
dtuAlarmControlEntry OBJECT-TYPE
SYNTAX DtuAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU alarm control table."
INDEX { dtuAlarmSlotIndex , dtuAlarmPortIndex }
::= { dtuAlarmControlTable 1 }
DtuAlarmControlEntry ::= SEQUENCE {
dtuAlarmSlotIndex LargeSlotIndex,
dtuAlarmPortIndex TenPortID,
dtuLineUnsync AlarmSeverity
}
dtuAlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuAlarmControlEntry 1 }
dtuAlarmPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuAlarmControlEntry 2 }
dtuLineUnsync OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm : Line Unsync"
::= { dtuAlarmControlEntry 3 }
--
-- Current Line Performance Table
--
dtuCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU current line performance table."
::= { dtu-card 6 }
dtuCurrentPerfEntry OBJECT-TYPE
SYNTAX DtuCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU current line performance table."
INDEX { dtuCurrSlotIndex , dtuCurrPortIndex }
::= { dtuCurrentPerfTable 1 }
DtuCurrentPerfEntry ::= SEQUENCE {
dtuCurrSlotIndex LargeSlotIndex,
dtuCurrPortIndex TenPortID,
dtuCurrentAS INTEGER,
dtuCurrentUAS INTEGER,
dtuCurrent24hAS INTEGER,
dtuCurrent24hUAS INTEGER,
dtuValid15minInterval INTEGER,
dtuValid1dayInterval INTEGER
}
dtuCurrSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuCurrentPerfEntry 1 }
dtuCurrPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuCurrentPerfEntry 2 }
dtuCurrentAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"15m Performance available seconds"
::= { dtuCurrentPerfEntry 3 }
dtuCurrentUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"15m Performance unavailable seconds"
::= { dtuCurrentPerfEntry 4 }
dtuCurrent24hAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24h Performance available seconds"
::= { dtuCurrentPerfEntry 5 }
dtuCurrent24hUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24h Performance unavailable seconds"
::= { dtuCurrentPerfEntry 6 }
dtuValid15minInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Valid 15 minutes Interval number"
::= { dtuCurrentPerfEntry 7 }
dtuValid1dayInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Valid 1 day Interval number"
::= { dtuCurrentPerfEntry 8 }
--
-- Interval Line Performance Table
--
dtuIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU interval line performance table."
::= { dtu-card 7 }
dtuIntervalPerfEntry OBJECT-TYPE
SYNTAX DtuIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU interval line performance table."
INDEX { dtuPerfSlotIndex ,
dtuPerfPortIndex ,
dtuItvIndex }
::= { dtuIntervalPerfTable 1 }
DtuIntervalPerfEntry ::= SEQUENCE {
dtuPerfSlotIndex LargeSlotIndex,
dtuPerfPortIndex TenPortID,
dtuItvIndex INTEGER,
dtuIntervalAS INTEGER,
dtuIntervalUAS INTEGER
}
dtuPerfSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuIntervalPerfEntry 1 }
dtuPerfPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuIntervalPerfEntry 2 }
dtuItvIndex OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance interval index"
::= { dtuIntervalPerfEntry 3 }
dtuIntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance available seconds"
::= { dtuIntervalPerfEntry 4 }
dtuIntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance unavailable seconds"
::= { dtuIntervalPerfEntry 5 }
--
-- Total Line Performance Table
--
dtuTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU total line performance table."
::= { dtu-card 8 }
dtuTotalPerfEntry OBJECT-TYPE
SYNTAX DtuTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU total line performance table."
INDEX { dtuTPerfSlotIndex ,
dtuTPerfPortIndex ,
dtuTotalIndex }
::= { dtuTotalPerfTable 1 }
DtuTotalPerfEntry ::= SEQUENCE {
dtuTPerfSlotIndex LargeSlotIndex,
dtuTPerfPortIndex TenPortID,
dtuTotalIndex INTEGER,
dtuTotalAS INTEGER,
dtuTotalUAS INTEGER
}
dtuTPerfSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuTotalPerfEntry 1 }
dtuTPerfPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuTotalPerfEntry 2 }
dtuTotalIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance interval index"
::= { dtuTotalPerfEntry 3 }
dtuTotalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day performance available seconds"
::= { dtuTotalPerfEntry 4 }
dtuTotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day performance unavailable seconds"
::= { dtuTotalPerfEntry 5 }
--
-- LED Status Table
--
dtuRemLedStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRemLedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTU remote LED status table."
::= { dtu-card 9 }
dtuRemLedStatusEntry OBJECT-TYPE
SYNTAX DtuRemLedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LED status entry"
INDEX { dtuLedSlotIndex , dtuLedPortIndex }
::= { dtuRemLedStatusTable 1 }
DtuRemLedStatusEntry ::= SEQUENCE {
dtuLedSlotIndex LargeSlotIndex,
dtuLedPortIndex TenPortID,
dtuLedColor INTEGER
}
dtuLedSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRemLedStatusEntry 1 }
dtuLedPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuRemLedStatusEntry 2 }
dtuLedColor OBJECT-TYPE
SYNTAX INTEGER {
none(0),
off(1),
red(2),
green(3),
flashing-green(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Led Color"
::= { dtuRemLedStatusEntry 3 }
--
-- DTU Line Config Table
--
dtuLineConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuLineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU line configuration."
::= { dtu-card 10 }
dtuLineConfigEntry OBJECT-TYPE
SYNTAX DtuLineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU line configuration."
INDEX { dtuConfigSlotIndex , dtuConfigPortIndex }
::= { dtuLineConfigTable 1 }
DtuLineConfigEntry ::= SEQUENCE {
dtuConfigSlotIndex LargeSlotIndex,
dtuConfigPortIndex TenPortID,
dtuLineMode INTEGER,
dtuLineProtocol INTEGER,
dtuClockSource INTEGER
}
dtuConfigSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuLineConfigEntry 1 }
dtuConfigPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-10"
::= { dtuLineConfigEntry 2 }
dtuLineMode OBJECT-TYPE
SYNTAX INTEGER {
lT(1),
nT(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU Line Mode"
::= { dtuLineConfigEntry 3 }
dtuLineProtocol OBJECT-TYPE
SYNTAX INTEGER {
d-channel(1),
m-channel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU Line protocol channel"
::= { dtuLineConfigEntry 4 }
dtuClockSource OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
dTE-1(2),
dTE-2(3),
line(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU master clock source"
::= { dtuLineConfigEntry 5 }
--
-- 15 minutes Interval Performance Table
--
dtu15minIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu15minIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU 15 minutes interval performance table."
::= { dtu-card 17 }
dtu15minIntervalPerfEntry OBJECT-TYPE
SYNTAX Dtu15minIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU 15 minutes interval performance table."
INDEX { dtuPerfSlotIndex ,
dtuPerfPortIndex ,
dtuItvIndex }
::= { dtu15minIntervalPerfTable 1 }
Dtu15minIntervalPerfEntry ::= SEQUENCE {
dtu15minIntervalAS INTEGER,
dtu15minIntervalUAS INTEGER
}
dtu15minIntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Available Seconds"
::= { dtu15minIntervalPerfEntry 4 }
dtu15minIntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UnAvailable Seconds"
::= { dtu15minIntervalPerfEntry 5 }
--
-- 1 Day Interval Performance Table
--
dtu1dayIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu1dayIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU total line performance table."
::= { dtu-card 18 }
dtu1dayIntervalPerfEntry OBJECT-TYPE
SYNTAX Dtu1dayIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU total line performance table."
INDEX { dtuTPerfSlotIndex ,
dtuTPerfPortIndex ,
dtuTotalIndex }
::= { dtu1dayIntervalPerfTable 1 }
Dtu1dayIntervalPerfEntry ::= SEQUENCE {
dtu1dayIntervalAS INTEGER,
dtu1dayIntervalUAS INTEGER
}
dtu1dayIntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Available Seconds"
::= { dtu1dayIntervalPerfEntry 4 }
dtu1dayIntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UnAvailable Seconds"
::= { dtu1dayIntervalPerfEntry 5 }
--
-- Remote Router Table
--
dtuRouterConfig OBJECT IDENTIFIER ::= { dtu-card 11 }
--
-- NI Control Table
--
dtuRtrNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Table"
::= { dtuRouterConfig 1 }
dtuRouterNiControlEntry OBJECT-TYPE
SYNTAX DtuRtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Entry"
INDEX { dtuRtrNiUnitIndex ,
dtuRtrNiPortIndex ,
dtuRtrNiIndex }
::= { dtuRtrNiControlTable 1 }
DtuRtrNiControlEntry ::= SEQUENCE {
dtuRtrNiUnitIndex LargeSlotIndex,
dtuRtrNiPortIndex TenPortID,
dtuRtrNiIndex INTEGER,
dtuRtrIPAddr IpAddress,
dtuRtrSubnetMask IpAddress,
dtuRtrFrame INTEGER,
dtuRtrRIP1 INTEGER,
dtuRtrRIP2 INTEGER,
dtuRtrMode INTEGER
}
dtuRtrNiUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRouterNiControlEntry 1 }
dtuRtrNiPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~10, total 10 ports."
::= { dtuRouterNiControlEntry 2 }
dtuRtrNiIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
-- wan2(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Ni index"
::= { dtuRouterNiControlEntry 3 }
dtuRtrIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR IP Address"
::= { dtuRouterNiControlEntry 4 }
dtuRtrSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR net mask"
::= { dtuRouterNiControlEntry 5 }
dtuRtrFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
ethernet(4),
na(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Layer2 frame"
::= { dtuRouterNiControlEntry 6 }
dtuRtrRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP1"
::= { dtuRouterNiControlEntry 7 }
dtuRtrRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP2"
::= { dtuRouterNiControlEntry 8 }
dtuRtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR mode"
::= { dtuRouterNiControlEntry 9 }
--
-- Route Table
--
dtuRtrRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Table"
::= { dtuRouterConfig 2 }
dtuRouterRouteControlEntry OBJECT-TYPE
SYNTAX DtuRtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Entry"
INDEX { dtuRtrRUnitIndex ,
dtuRtrRPortIndex ,
dtuRtrEntry }
::= { dtuRtrRouteControlTable 1 }
DtuRtrRouteControlEntry ::= SEQUENCE {
dtuRtrRUnitIndex LargeSlotIndex,
dtuRtrRPortIndex TenPortID,
dtuRtrEntry INTEGER (1..16),
dtuRtrNetAddr IpAddress,
dtuRtrNetMask IpAddress,
dtuRtrGatewayAddr IpAddress,
dtuRtrNIAddr IpAddress,
dtuRtrMetric INTEGER
}
dtuRtrRUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRouterRouteControlEntry 1 }
dtuRtrRPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~10, total 10 ports."
::= { dtuRouterRouteControlEntry 2 }
dtuRtrEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Route Entry"
::= { dtuRouterRouteControlEntry 3 }
dtuRtrNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net Address"
::= { dtuRouterRouteControlEntry 4 }
dtuRtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net mask"
::= { dtuRouterRouteControlEntry 5 }
dtuRtrGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route gateway Address"
::= { dtuRouterRouteControlEntry 6 }
dtuRtrNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route NI Address"
::= { dtuRouterRouteControlEntry 7 }
dtuRtrMetric OBJECT-TYPE
SYNTAX INTEGER {
na(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Route metric"
::= { dtuRouterRouteControlEntry 8 }
--
-- Router Command
--
dtuRtrCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command(reset & load-default) Table"
::= { dtuRouterConfig 3 }
dtuRtrCommandEntry OBJECT-TYPE
SYNTAX DtuRtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Entry"
INDEX { dtuRtrCmdUnitIndex ,
dtuRtrCmdPortIndex }
::= { dtuRtrCommandTable 1 }
DtuRtrCmdEntry ::= SEQUENCE {
dtuRtrCmdUnitIndex LargeSlotIndex,
dtuRtrCmdPortIndex TenPortID,
dtuRtrCommand INTEGER,
dtuCrcMode INTEGER
}
dtuRtrCmdUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRtrCommandEntry 1 }
dtuRtrCmdPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~10, total 10 ports."
::= { dtuRtrCommandEntry 2 }
dtuRtrCommand OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
load-default(2),
none(3),
re-get-map-cfg(11),
re-get-ni-cfg(12),
re-get-rtr-cfg(13),
re-get-crc-cfg(14),
re-get-all-cfg(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Command(reset or load-default)"
::= { dtuRtrCommandEntry 3 }
dtuCrcMode OBJECT-TYPE
SYNTAX INTEGER {
no-padding(1),
padding(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CRC mode"
::= { dtuRtrCommandEntry 4 }
--
-- Router Map
--
dtuRtrMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Table"
::= { dtuRouterConfig 4 }
dtuRtrMapEntry OBJECT-TYPE
SYNTAX DtuRtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Entry"
INDEX { dtuRtrMapUnitIndex ,
dtuRtrMapPortIndex }
::= { dtuRtrMapTable 1 }
DtuRtrMappingEntry ::= SEQUENCE {
dtuRtrMapUnitIndex LargeSlotIndex,
dtuRtrMapPortIndex TenPortID,
dtuRtrChB1 INTEGER,
dtuRtrChB2 INTEGER
}
dtuRtrMapUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRtrMapEntry 1 }
dtuRtrMapPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~10, total 10 ports."
::= { dtuRtrMapEntry 2 }
dtuRtrChB1 OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
-- wan2(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" U channel B1 map data"
::= { dtuRtrMapEntry 3 }
dtuRtrChB2 OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
-- wan2(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" U channel B2 map data"
::= { dtuRtrMapEntry 4 }
--
-- DTU Remote DTU Information Table
--
dtuRemoteDTUInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuRemoteDTUInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote DTU Information Table."
::= { dtu-card 12 }
dtuRemoteDTUInfoEntry OBJECT-TYPE
SYNTAX DtuRemoteDTUInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Remote DTU Information Table."
INDEX { dtuRemoteDTUInfoSlotIndex ,
dtuRemoteDTUInfoPortIndex }
::= { dtuRemoteDTUInfoTable 1 }
DtuRemoteDTUInfoEntry ::= SEQUENCE {
dtuRemoteDTUInfoSlotIndex LargeSlotIndex,
dtuRemoteDTUInfoPortIndex TenPortID,
dtuRemoteDTUInfoDate DisplayString,
dtuRemoteDTUInfoSerialNumber DisplayString,
dtuRemoteDTUInfoSWVersion DisplayString,
dtuRemoteDTUInfoConfiguration DisplayString
}
dtuRemoteDTUInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuRemoteDTUInfoEntry 1 }
dtuRemoteDTUInfoPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-6"
::= { dtuRemoteDTUInfoEntry 2 }
dtuRemoteDTUInfoDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote DTU Date "
::= { dtuRemoteDTUInfoEntry 3 }
dtuRemoteDTUInfoSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Serial Number"
::= { dtuRemoteDTUInfoEntry 4 }
dtuRemoteDTUInfoSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Software Version"
::= { dtuRemoteDTUInfoEntry 5 }
dtuRemoteDTUInfoConfiguration OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Configuration"
::= { dtuRemoteDTUInfoEntry 6 }
--
-- DTU Line Status Table
--
dtuLineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DtuLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTU line status table."
::= { dtu-card 13 }
dtuLineStatusEntry OBJECT-TYPE
SYNTAX DtuLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU line status table."
INDEX { dtuLineStatusSlotIndex ,
dtuLineStatusPortIndex }
::= { dtuLineStatusTable 1 }
DtuLineStatusEntry ::= SEQUENCE {
dtuLineStatusSlotIndex LargeSlotIndex,
dtuLineStatusPortIndex TenPortID,
dtuLineLocalCRC INTEGER,
dtuLineLocalIntervalAVG DisplayString,
dtuLineRemoteCRC INTEGER,
dtuLineRemoteIntervalAVG DisplayString
}
dtuLineStatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtuLineStatusEntry 1 }
dtuLineStatusPortIndex OBJECT-TYPE
SYNTAX TenPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-10"
::= { dtuLineStatusEntry 2 }
dtuLineLocalCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port Local CRC Error."
::= { dtuLineStatusEntry 3 }
dtuLineLocalIntervalAVG OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTU port local CRC Interval Average."
::= { dtuLineStatusEntry 4 }
dtuLineRemoteCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port Remote CRC Error."
::= { dtuLineStatusEntry 5 }
dtuLineRemoteIntervalAVG OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTU port remote CRC Interval Average."
::= { dtuLineStatusEntry 6 }
dtuTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of DTU"
::= { dtu-card 100 }
--======================================================================--
--======================================================================--
-- dte card MIB
--======================================================================--
--======================================================================--
--
-- DTE Control Table
--
dteConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTEConfigControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Configuration Control Table"
::= { dte-card 1 }
dteConfigCtrlEntry OBJECT-TYPE
SYNTAX DTEConfigControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE configuration control entry"
INDEX {
dteIndex ,
dtePortIndex
}
::= { dteConfigControlTable 1 }
DTEConfigControl ::= SEQUENCE {
dteIndex LargeSlotIndex,
dtePortIndex SixPortID,
dteRate INTEGER,
dteChannel INTEGER,
dteClock INTEGER,
dteData INTEGER,
dteInterface INTEGER,
dteRTS INTEGER,
dteTTM INTEGER,
dteV54 INTEGER
}
dteIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dteConfigCtrlEntry 1 }
dtePortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports"
::= { dteConfigCtrlEntry 2 }
dteRate OBJECT-TYPE
SYNTAX INTEGER {
rate64k(1),
rate56k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Rate "
::= { dteConfigCtrlEntry 3 }
dteChannel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Channel: channel numbers designed by MAP."
::= { dteConfigCtrlEntry 4 }
dteClock OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Clock Polarity "
::= { dteConfigCtrlEntry 5 }
dteData OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Data Polarity "
::= { dteConfigCtrlEntry 6 }
dteInterface OBJECT-TYPE
SYNTAX INTEGER {
eia530(1),
x21(2),
rs232(3),
v35(4),
v36(5),
rs422(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Interface Type "
::= { dteConfigCtrlEntry 7 }
dteRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE RTS Permanent "
::= { dteConfigCtrlEntry 8 }
dteTTM OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Terminal Timing Mode "
::= { dteConfigCtrlEntry 9 }
dteV54 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE V54 control "
::= { dteConfigCtrlEntry 10 }
--
-- Alarm Queue Table
--
dteAlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTEAlarmQueue
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Alarm Queue Table"
::= { dte-card 2 }
dteAlarmQueueEntry OBJECT-TYPE
SYNTAX DTEAlarmQueue
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE alarm queue entry"
INDEX { dteIndex ,
dtePortIndex ,
dteAlarmQIndex }
::= { dteAlarmQueueTable 1 }
DTEAlarmQueue ::= SEQUENCE {
dteAlarmQIndex INTEGER (1..40),
alarmQStr DisplayString (SIZE(0..255))
}
dteAlarmQIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { dteAlarmQueueEntry 2 }
alarmQStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { dteAlarmQueueEntry 3 }
--
-- Alarm History Table
--
dteAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTEAlarmHistory
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Alarm History Table"
::= { dte-card 3 }
dteAlarmHistoryEntry OBJECT-TYPE
SYNTAX DTEAlarmHistory
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE alarm history entry"
INDEX { dteIndex ,
dtePortIndex ,
dteAlarmHIndex }
::= { dteAlarmHistoryTable 1 }
DTEAlarmHistory ::= SEQUENCE {
dteAlarmHIndex INTEGER,
currentHState INTEGER,
countH INTEGER,
alarmH AlarmSeverity
}
dteAlarmHIndex OBJECT-TYPE
SYNTAX INTEGER {
dte-alarm(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { dteAlarmHistoryEntry 2 }
currentHState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { dteAlarmHistoryEntry 3 }
countH OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { dteAlarmHistoryEntry 4 }
alarmH OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { dteAlarmHistoryEntry 5 }
--
-- Alarm Control Table
--
dteAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTEAlarmControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { dte-card 4 }
dteAlarmCtrlEntry OBJECT-TYPE
SYNTAX DTEAlarmControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE alarm control table."
INDEX { dteIndex ,
dtePortIndex
}
::= { dteAlarmControlTable 1 }
DTEAlarmControl ::= SEQUENCE {
alarmDte AlarmSeverity,
alarmHistoryReset INTEGER
-- alarmQueueReset
-- INTEGER
}
alarmDte OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm State"
::= { dteAlarmCtrlEntry 2 }
alarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { dteAlarmCtrlEntry 3 }
-- alarmQueueReset OBJECT-TYPE
-- SYNTAX INTEGER {
-- reset(1)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Command: Reset Alarm Queue "
-- ::= { dteCommandCtrlEntry 2 }
--
-- Line Diagnostic Control Table
--
dteLineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTELineDiagControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Diagnostic Control Table."
::= { dte-card 5 }
dteDiagCtrlEntry OBJECT-TYPE
SYNTAX DTELineDiagControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of DTE diagnostic control table."
INDEX { dteIndex ,
dtePortIndex
}
::= { dteLineDiagControlTable 1 }
DTELineDiagControl ::= SEQUENCE {
loopbacktype INTEGER,
loopbackstatus INTEGER,
bertctrl INTEGER,
bertstatus INTEGER,
elapseseconds INTEGER,
errorseconds INTEGER,
errorcounts INTEGER
}
loopbacktype OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
loopback-To-DTE(2),
loopback-To-Line(3),
remoteV54-active(4),
remoteV54-deactive(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE Loopback Type"
::= { dteDiagCtrlEntry 2 }
loopbackstatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE Loopback Status"
::= { dteDiagCtrlEntry 3 }
bertctrl OBJECT-TYPE
SYNTAX INTEGER {
bert-DEACTIVE(1),
prbs-ACTIVE-DTE(2),
qrss-ACTIVE-DTE(3),
bert-RESET-ERROR-COUNT(4),
bert-INJECT-ERROR(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE PRBS/QRSS Control"
::= { dteDiagCtrlEntry 4 }
bertstatus OBJECT-TYPE
SYNTAX INTEGER {
bert-SYNC(1),
bert-UNSYNC(2),
bert-NOT-ACTIVE(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE PRBS/QRSS Status"
::= { dteDiagCtrlEntry 5 }
elapseseconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte PRBS/QRSS Elapse Seconds"
::= { dteDiagCtrlEntry 6 }
errorseconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte PRBS/QRSS Error Seconds"
::= { dteDiagCtrlEntry 7 }
errorcounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte PRBS/QRSS Error Counts"
::= { dteDiagCtrlEntry 8 }
--
-- Command Control Table
--
dteCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTECommandControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { dte-card 6 }
dteCommandCtrlEntry OBJECT-TYPE
SYNTAX DTECommandControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { dteIndex
-- dtePortIndex
}
::= { dteCommandControlTable 1 }
DTECommandControl ::= SEQUENCE {
portReset INTEGER,
portLoadDefault INTEGER
}
portReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset DTE Port"
::= { dteCommandCtrlEntry 3 }
portLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
loadDefault(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default DTE Port"
::= { dteCommandCtrlEntry 4 }
--
-- SYSTEM Information Table
--
dteSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTESystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { dte-card 7 }
dteSystemInfoEntry OBJECT-TYPE
SYNTAX DTESystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { dteIndex
}
::= { dteSystemInformationTable 1 }
DTESystemInformation ::= SEQUENCE {
promVersion DisplayString
}
promVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE EPROM Version"
::= { dteSystemInfoEntry 2 }
--
-- DTE Status Table
--
dteStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF DTEStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE status table."
::= { dte-card 8 }
dteStatusEntry OBJECT-TYPE
SYNTAX DTEStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE status table."
INDEX { dteIndex ,
dtePortIndex
}
::= { dteStatusTable 1 }
DTEStatus ::= SEQUENCE {
statusRTS INTEGER,
statusCTS INTEGER,
statusDSR INTEGER,
statusDCD INTEGER,
extclkloss INTEGER
}
statusRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE RTS status "
::= { dteStatusEntry 2 }
statusCTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE CTS status "
::= { dteStatusEntry 3 }
statusDSR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE DSR status "
::= { dteStatusEntry 4 }
statusDCD OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE DCD status "
::= { dteStatusEntry 5 }
extclkloss OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
loss(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE external clock loss "
::= { dteStatusEntry 6 }
dteTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of DTE"
::= { dte-card 100 }
--======================================================================--
--======================================================================--
-- x50-card MIB
--======================================================================--
--======================================================================--
--
-- X50 Configuartion
--
x50ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The X50 Interface Configuration table."
::= { x50-card 1 }
x50ConfigEntry OBJECT-TYPE
SYNTAX X50ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the X50 Configuration table."
INDEX { x50ConfigSlotIndex , x50ConfigPortIndex }
::= { x50ConfigTable 1 }
X50ConfigEntry ::= SEQUENCE {
x50ConfigSlotIndex LargeSlotIndex,
x50ConfigPortIndex EightPortID,
x50Channel INTEGER,
x50Mux INTEGER,
x50SyncMode INTEGER,
x50Rate INTEGER,
x50Phase INTEGER,
x5048k-sel INTEGER,
x50ClockPolarity INTEGER,
x50DataPolarity INTEGER,
x50RTS INTEGER,
x50TTM INTEGER,
x50Interface INTEGER,
x50Warrning INTEGER,
x50DCD INTEGER
}
x50ConfigSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50ConfigEntry 1 }
x50ConfigPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 port 1-5"
::= { x50ConfigEntry 2 }
x50Channel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 Used channel"
::= { x50ConfigEntry 3 }
x50Mux OBJECT-TYPE
SYNTAX INTEGER {
noMux(1),
mux(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 MUX mode"
::= { x50ConfigEntry 4 }
x50SyncMode OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
async8(2),
async9(3),
async10(4),
async11(5),
async12(6),
na(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Sync mode"
::= { x50ConfigEntry 5 }
x50Rate OBJECT-TYPE
SYNTAX INTEGER {
r0-6K(0),
r1-2K(1),
r2-4K(2),
r4-8K(3),
r9-6K(4),
r19-2K(5),
r38-4K(6),
r48K(7),
r64K(8),
na(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Base Rate"
::= { x50ConfigEntry 6 }
x50Phase OBJECT-TYPE
SYNTAX INTEGER {
ph1(1),
ph2(2),
ph3(3),
ph4(4),
ph5(5),
na(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Phase select"
::= { x50ConfigEntry 7 }
x5048k-sel OBJECT-TYPE
SYNTAX INTEGER {
firstHalf(1),
lastHalf(2),
oddPair(3),
evenPair(4),
na(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 4.8k map select"
::= { x50ConfigEntry 8 }
x50ClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Clock Polarity"
::= { x50ConfigEntry 9 }
x50DataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Data Polarity"
::= { x50ConfigEntry 10 }
x50RTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 RTS Mode"
::= { x50ConfigEntry 11 }
x50TTM OBJECT-TYPE
SYNTAX INTEGER {
ttmOff(1),
ttmOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 TTM Mode"
::= { x50ConfigEntry 12 }
x50Interface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
rs449-eia530(2),
x21(3),
rs232(4),
na(16),
rs232-x50(24),
db25-rj(41),
rj-only(42)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 Interface Type"
::= { x50ConfigEntry 13 }
x50Warrning OBJECT-TYPE
SYNTAX INTEGER {
no(1),
overlap(2),
na(3)
}
-- SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 map setup warrning"
::= { x50ConfigEntry 14 }
x50DCD OBJECT-TYPE
SYNTAX INTEGER {
remote-all-1-forward(1),
permanent-ON(2),
remote-X50-forward(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 DCD setup"
::= { x50ConfigEntry 15 }
--
-- X50 Status
--
x50StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The X50 Interface Status table."
::= { x50-card 2 }
x50StatusEntry OBJECT-TYPE
SYNTAX X50StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the X50 Status table."
INDEX { x50StatusSlotIndex , x50StatusPortIndex }
::= { x50StatusTable 1 }
X50StatusEntry ::= SEQUENCE {
x50StatusSlotIndex LargeSlotIndex,
x50StatusPortIndex EightPortID,
x50Existed INTEGER,
x50RTSloss INTEGER,
x50EXTCLKloss INTEGER,
x50DSRstatus INTEGER,
x50CTSstatus INTEGER,
x50DCDstatus INTEGER,
x50DTRstatus INTEGER,
x50RTSstatus INTEGER,
x50RemoteAlarm INTEGER
}
x50StatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50StatusEntry 1 }
x50StatusPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 port 1-5"
::= { x50StatusEntry 2 }
x50Existed OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 Existed"
::= { x50StatusEntry 3 }
x50RTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 RTS loss"
::= { x50StatusEntry 4 }
x50EXTCLKloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 EXT-CLK loss"
::= { x50StatusEntry 5 }
x50DSRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 DSR"
::= { x50StatusEntry 6 }
x50CTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 CTS"
::= { x50StatusEntry 7 }
x50DCDstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 DCD"
::= { x50StatusEntry 8 }
x50DTRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 DTR"
::= { x50StatusEntry 9 }
x50RTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 RTS"
::= { x50StatusEntry 10 }
x50RemoteAlarm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 RTS"
::= { x50StatusEntry 11 }
--
-- Alarm History Table
--
x50AlmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: x50AlmHistoryUnitIndex "
::= { x50-card 3 }
x50AlmHistoryEntry OBJECT-TYPE
SYNTAX X50AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { x50AlmHistorySlotIndex , x50AlmHistoryPortIndex }
::= { x50AlmHistoryTable 1 }
X50AlmHistoryEntry ::= SEQUENCE {
x50AlmHistorySlotIndex LargeSlotIndex,
x50AlmHistoryPortIndex EightPortID,
x50AlmHistoryState INTEGER,
x50AlmHistoryCount INTEGER,
x50AlmHistoryEnable AlarmSeverity
}
x50AlmHistorySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50AlmHistoryEntry 1 }
x50AlmHistoryPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 port 1-5"
::= { x50AlmHistoryEntry 2 }
x50AlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { x50AlmHistoryEntry 3 }
x50AlmHistoryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { x50AlmHistoryEntry 4 }
x50AlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { x50AlmHistoryEntry 5 }
--
-- Alarm Control Table
--
x50AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The x50 alarm control table."
::= { x50-card 4 }
x50AlarmControlEntry OBJECT-TYPE
SYNTAX X50AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the x50 alarm control table."
INDEX { x50AlarmSlotIndex , x50AlarmPortIndex }
::= { x50AlarmControlTable 1 }
X50AlarmControlEntry ::= SEQUENCE {
x50AlarmSlotIndex LargeSlotIndex,
x50AlarmPortIndex EightPortID,
x50AlarmSetup AlarmSeverity
}
x50AlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50AlarmControlEntry 1 }
x50AlarmPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 port 1-5"
::= { x50AlarmControlEntry 2 }
x50AlarmSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { x50AlarmControlEntry 3 }
--
-- Diagnostic Control Table
--
x50DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { x50-card 5 }
x50DiagControlEntry OBJECT-TYPE
SYNTAX X50DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { x50DiagControlSlotIndex , x50DiagControlPortIndex }
::= { x50DiagControlTable 1 }
X50DiagControlEntry ::= SEQUENCE {
x50DiagControlSlotIndex LargeSlotIndex,
x50DiagControlPortIndex EightPortID,
x50NearLoopback INTEGER,
-- x50V54Loopback
-- INTEGER,
x50BERTControl INTEGER,
x50BERTStatus INTEGER,
x50BERTElapsedSeconds INTEGER,
x50BERTErrorSeconds INTEGER,
x50BERTErrorCounts INTEGER
}
x50DiagControlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50DiagControlEntry 1 }
x50DiagControlPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"X50 port 1-5"
::= { x50DiagControlEntry 2 }
x50NearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
x50-TO-DTE(2),
x50-TO-DS1(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"X50 Loopback Type"
::= { x50DiagControlEntry 3 }
x50BERTControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-ON(2),
reset(3),
inject-Error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Control"
::= { x50DiagControlEntry 4 }
x50BERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-SYNC(1),
bert-UNSYNC(2),
bert-NOT-ACTIVE(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { x50DiagControlEntry 5 }
x50BERTElapsedSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Elapsed Time"
::= { x50DiagControlEntry 6 }
x50BERTErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Error Seconds"
::= { x50DiagControlEntry 7 }
x50BERTErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Error Counter"
::= { x50DiagControlEntry 8 }
--
-- Card Control Table
--
x50CardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The x50 Card control table."
::= { x50-card 7 }
x50CardControlEntry OBJECT-TYPE
SYNTAX X50CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the x50 Card control table."
INDEX { x50CardIndex }
::= { x50CardControlTable 1 }
X50CardControlEntry ::= SEQUENCE {
x50CardIndex LargeSlotIndex,
x50Reset INTEGER,
x50LoadDefault INTEGER
}
x50CardIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50CardControlEntry 1 }
x50Reset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset x50 card"
::= { x50CardControlEntry 2 }
x50LoadDefault OBJECT-TYPE
SYNTAX INTEGER {
default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { x50CardControlEntry 3 }
--
-- Card Information Table
--
x50CardInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF X50CardInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The x50 Card information."
::= { x50-card 8 }
x50CardInformationEntry OBJECT-TYPE
SYNTAX X50CardInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the x50 Card Information."
INDEX { x50CardInformationIndex }
::= { x50CardInformationTable 1 }
X50CardInformationEntry ::= SEQUENCE {
x50CardInformationIndex LargeSlotIndex,
x50SoftwareVersion DisplayString
}
x50CardInformationIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { x50CardInformationEntry 1 }
x50SoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"x50 card software version"
::= { x50CardInformationEntry 2 }
x50TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of X50"
::= { x50-card 100 }
--======================================================================--
--======================================================================--
-- mdsl MIB
--======================================================================--
--======================================================================--
--
-- MDSL SYSTEM Table
--
xdslSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system control table."
::= { mdsl-card 1 }
xdslSystemEntry OBJECT-TYPE
SYNTAX XdslSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system table."
INDEX { xdslIndex ,
xdslPortIndex ,
xdslSysHTUIndex }
::= { xdslSystemTable 1 }
XdslSystemEntry ::= SEQUENCE {
xdslIndex LargeSlotIndex,
xdslPortIndex ThreePortID,
xdslSysHTUIndex INTEGER,
xdslMode INTEGER,
xdslServiceType INTEGER,
xdslClockSource INTEGER,
xdslSWVersion DisplayString,
xdslClearPerformance INTEGER,
xdslSerialNumber INTEGER
}
xdslIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { xdslSystemEntry 1 }
xdslPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~3, total 3 slots."
::= { xdslSystemEntry 2 }
xdslSysHTUIndex OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote"
::= { xdslSystemEntry 3 }
xdslMode OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"xDSL mode (Master or Slave)"
::= { xdslSystemEntry 4 }
xdslServiceType OBJECT-TYPE
SYNTAX INTEGER {
one-pair(1),
two-pairs(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Service Configuration"
::= { xdslSystemEntry 5 }
xdslClockSource OBJECT-TYPE
SYNTAX INTEGER {
line(1),
internal(2),
dte(3),
e1(4),
t1(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" System Master Clock Source"
::= { xdslSystemEntry 6 }
xdslSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Software Version"
::= { xdslSystemEntry 7 }
xdslClearPerformance OBJECT-TYPE
SYNTAX INTEGER {
none(1),
clear(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear Performance"
::= { xdslSystemEntry 8 }
xdslSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
none(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number of remote site"
::= { xdslSystemEntry 9 }
--
-- xDSL Line Configuartion for Loop-1, Loop-2
--
xdslLineConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslLineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The xDSL Line Configuration table."
::= { mdsl-card 2 }
xdslLineConfigEntry OBJECT-TYPE
SYNTAX XdslLineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the xDSL Line Configuration table."
INDEX { xdslIndex ,
xdslPortIndex ,
xdslLineLoopNumber }
::= { xdslLineConfigTable 1 }
XdslLineConfigEntry ::= SEQUENCE {
xdslLineLoopNumber INTEGER,
xdslLineRate INTEGER,
xdslLineCode INTEGER
}
xdslLineLoopNumber OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit Loop Number"
::= { xdslLineConfigEntry 2 }
xdslLineRate OBJECT-TYPE
SYNTAX INTEGER {
r272Kbps(1),
r400Kbps(2),
r528Kbps(3),
r784Kbps(4),
r1168Kbps(5),
r1552Kbps(6),
r2064Kbps(8),
r2320Kbps(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To describe xDSL Line Rate of specified loop,
for an example: 784Kbps"
::= { xdslLineConfigEntry 3 }
xdslLineCode OBJECT-TYPE
SYNTAX INTEGER {
xdsl-2b1q(1),
xdsl-cap(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xDSL Line Coding"
::= { xdslLineConfigEntry 4 }
--
-- xDSL AI Configuartion
--
xdslAIConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslAIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The xDSL Application Interface Configuration table."
::= { mdsl-card 3 }
xdslAIConfigEntry OBJECT-TYPE
SYNTAX XdslAIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the xDSL AI Configuration table."
INDEX { xdslIndex ,
xdslPortIndex ,
xdslAiNumber }
::= { xdslAIConfigTable 1 }
XdslAIConfigEntry ::= SEQUENCE {
xdslAiNumber INTEGER,
xdslDteReady INTEGER,
xdslDteRate INTEGER,
xdslDteClockPolarity INTEGER,
xdslDteDataPolarity INTEGER,
xdslDteRTS INTEGER,
xdslDteTTM INTEGER,
xdslDteV54 INTEGER,
xdslDteInterface INTEGER,
xdslDS1Ready INTEGER,
xdslDS1Framing INTEGER,
xdslDS1Code INTEGER
}
xdslAiNumber OBJECT-TYPE
SYNTAX INTEGER {
-- local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote unit"
::= { xdslAIConfigEntry 2 }
xdslDteReady OBJECT-TYPE
SYNTAX INTEGER {
dte-ready(1),
dte-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE port is present or not"
::= { xdslAIConfigEntry 3 }
xdslDteRate OBJECT-TYPE
SYNTAX INTEGER {
dte64K(1),
dte128K(2),
dte192K(3),
dte256K(4),
dte320K(5),
dte384K(6),
dte448K(7),
dte512K(8),
dte576K(9),
dte640K(10),
dte704K(11),
dte768K(12),
dte832K(13),
dte896K(14),
dte960K(15),
dte1024K(16),
dte1088K(17),
dte1152K(18),
dte1216K(19),
dte1280K(20),
dte1344K(21),
dte1408K(22),
dte1472K(23),
dte1536K(24),
dte1600K(25),
dte1664K(26),
dte1728K(27),
dte1792K(28),
dte1856K(29),
dte1920K(30),
dte1984K(31),
dte2048K(32),
none(33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xDSL DTE Base Rate"
::= { xdslAIConfigEntry 4 }
xdslDteClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clock-normal(1),
clock-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DTE Clock Polarity"
::= { xdslAIConfigEntry 5 }
xdslDteDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
data-normal(1),
data-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DTE Data Polarity"
::= { xdslAIConfigEntry 6 }
xdslDteRTS OBJECT-TYPE
SYNTAX INTEGER {
rts-active(1),
rts-permanent(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DTE RTS Mode"
::= { xdslAIConfigEntry 7 }
xdslDteTTM OBJECT-TYPE
SYNTAX INTEGER {
ttm-off(1),
ttm-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DTE TTM Mode"
::= { xdslAIConfigEntry 8 }
xdslDteV54 OBJECT-TYPE
SYNTAX INTEGER {
v54-off(1),
v54-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DTE V.54 Loopback Mode"
::= { xdslAIConfigEntry 9 }
xdslDteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
eia530-rs449(2),
x21(3),
rs232(4),
none(5),
other(18),
router(19)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xDSL DTE Interface Type"
::= { xdslAIConfigEntry 10 }
xdslDS1Ready OBJECT-TYPE
SYNTAX INTEGER {
ds1-ready(1),
ds1-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"xDSL DS1 unit is present or not"
::= { xdslAIConfigEntry 11 }
xdslDS1Framing OBJECT-TYPE
SYNTAX INTEGER {
unframe(1),
d4(2),
esf(3),
crc-off(4),
crc-on(5),
cas-crc-off(6),
cas-crc-on(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DS1 Framing"
::= { xdslAIConfigEntry 12 }
xdslDS1Code OBJECT-TYPE
SYNTAX INTEGER {
b8zs(1),
ami(2),
hdb3(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" xDSL DS1 Coding"
::= { xdslAIConfigEntry 13 }
--
-- Current Performance Table
--
xdslCurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mdsl-card 4 }
xdslCurrPerfEntry OBJECT-TYPE
SYNTAX XdslCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslCurrPerfTypeIndex }
::= { xdslCurrPerfTable 1 }
XdslCurrPerfEntry ::= SEQUENCE {
xdslCurrPerfTypeIndex INTEGER,
xdslCurrES INTEGER,
xdslCurrSES INTEGER,
xdslCurrUAS INTEGER,
xdslCurr15MinTimeElapsed INTEGER,
xdslValid15MinInterval INTEGER
}
xdslCurrPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { xdslCurrPerfEntry 2 }
xdslCurrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { xdslCurrPerfEntry 3 }
xdslCurrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { xdslCurrPerfEntry 4 }
xdslCurrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { xdslCurrPerfEntry 5 }
xdslCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { xdslCurrPerfEntry 6 }
xdslValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { xdslCurrPerfEntry 7 }
--
-- Total Performance Table
--
xdslTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mdsl-card 5 }
xdslTotalPerfEntry OBJECT-TYPE
SYNTAX XdslTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslTotalPerfTypeIndex }
::= { xdslTotalPerfTable 1 }
XdslTotalPerfEntry ::= SEQUENCE {
xdslTotalPerfTypeIndex INTEGER,
xdslTotalES INTEGER,
xdslTotalSES INTEGER,
xdslTotalUAS INTEGER,
xdslLineAvailableSeconds INTEGER,
xdslLineUnavailableSeconds INTEGER
}
xdslTotalPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { xdslTotalPerfEntry 2 }
xdslTotalES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { xdslTotalPerfEntry 3 }
xdslTotalSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { xdslTotalPerfEntry 4 }
xdslTotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { xdslTotalPerfEntry 5 }
xdslLineAvailableSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Line Available Seconds "
::= { xdslTotalPerfEntry 6 }
xdslLineUnavailableSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Line Unavailable Seconds "
::= { xdslTotalPerfEntry 7 }
--
-- Interval Performance Table
--
xdslIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mdsl-card 6 }
xdslIntvPerfEntry OBJECT-TYPE
SYNTAX XdslIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslIntvPerfTypeIndex ,
xdslIntvPerfPeriod }
::= { xdslIntvPerfTable 1 }
XdslIntvPerfEntry ::= SEQUENCE {
xdslIntvPerfTypeIndex INTEGER,
xdslIntvPerfPeriod INTEGER,
xdslIntvES INTEGER,
xdslIntvSES INTEGER,
xdslIntvUAS INTEGER,
xdslIntvAvailable INTEGER
}
xdslIntvPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { xdslIntvPerfEntry 2 }
xdslIntvPerfPeriod OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Interval Period Number"
::= { xdslIntvPerfEntry 3 }
xdslIntvES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { xdslIntvPerfEntry 4 }
xdslIntvSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { xdslIntvPerfEntry 5 }
xdslIntvUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { xdslIntvPerfEntry 6 }
xdslIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { xdslIntvPerfEntry 7 }
--
-- xDSL FRACTIONAL TABLE
--
xdslFracTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: xdslFracUnitIndex.xdslFracNumber"
::= { mdsl-card 7 }
xdslFracEntry OBJECT-TYPE
SYNTAX XdslFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslFracNumber }
::= { xdslFracTable 1 }
XdslFracEntry ::= SEQUENCE {
xdslFracNumber INTEGER (1..32),
xdslFracIfIndex INTEGER
}
xdslFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"xdslFracNumber "
::= { xdslFracEntry 2 }
xdslFracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-dte(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"xdslFracIfIndex "
::= { xdslFracEntry 3 }
--
-- Diagnostic Control Table
--
xdslDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { mdsl-card 8 }
xdslDiagEntry OBJECT-TYPE
SYNTAX XdslDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { xdslIndex ,
xdslPortIndex }
::= { xdslDiagTable 1 }
XdslDiagEntry ::= SEQUENCE {
xdslLocalXdslLoopback INTEGER,
xdslRemoteXdslLoopback INTEGER,
xdslRemoteDteLoopback INTEGER,
xdslBERTControl INTEGER,
xdslBERTReset INTEGER,
xdslBERTStatus INTEGER,
xdslBERTCounter INTEGER,
xdslBERTElapsed INTEGER,
xdslremBERTControl INTEGER,
xdslremBERTReset INTEGER,
xdslremBERTStatus INTEGER,
xdslremBERTCounter INTEGER,
xdslremBERTElapsed INTEGER,
xdslremBERTErrorSeconds INTEGER,
xdslremBERTPatternUnsyncSeconds INTEGER
}
xdslLocalXdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
-- xdsl-to-line(2),
xdsl-to-local(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { xdslDiagEntry 2 }
xdslRemoteXdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-xdsl-to-line(2),
slave-xdsl-to-local(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { xdslDiagEntry 4 }
xdslRemoteDteLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-t1-to-line(2),
slave-t1-to-local(3),
slave-e1-to-line(4),
slave-e1-to-local(5),
slave-dte-to-line(6),
slave-dte-to-local(7),
slave-router-to-line(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE/T1/E1 Loopback Type"
::= { xdslDiagEntry 5 }
xdslBERTControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
-- bert-2-15-1(2),
bert-on(3),
bert-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Control"
::= { xdslDiagEntry 6 }
xdslBERTReset OBJECT-TYPE
SYNTAX INTEGER {
bert-no-action(1),
bert-restart(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Restart"
::= { xdslDiagEntry 7 }
xdslBERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { xdslDiagEntry 8 }
xdslBERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Counter"
::= { xdslDiagEntry 9 }
xdslBERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Elapsed Time"
::= { xdslDiagEntry 10 }
xdslremBERTControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
-- bert-2-15-1(2),
bert-on(3)
-- bert-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"remBert Control"
::= { xdslDiagEntry 11 }
xdslremBERTReset OBJECT-TYPE
SYNTAX INTEGER {
bert-no-action(1),
bert-restart(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"remBert Restart"
::= { xdslDiagEntry 12 }
xdslremBERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Status"
::= { xdslDiagEntry 13 }
xdslremBERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Counter"
::= { xdslDiagEntry 14 }
xdslremBERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Elapsed Time"
::= { xdslDiagEntry 15 }
xdslremBERTErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Error Seconds"
::= { xdslDiagEntry 16 }
xdslremBERTPatternUnsyncSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Pattern Unsync Seconds"
::= { xdslDiagEntry 17 }
--
-- Alarm Queue Table
--
xdslAlmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: xdslAlmQueueUnitIndex "
::= { mdsl-card 9 }
xdslAlmQueueEntry OBJECT-TYPE
SYNTAX XdslAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslAlmQueueNumber }
::= { xdslAlmQueueTable 1 }
XdslAlmQueueEntry ::= SEQUENCE {
xdslAlmQueueNumber INTEGER (1..40),
xdslAlmQueueString DisplayString (SIZE(0..80))
}
xdslAlmQueueNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Latest Alarm Queue number (1-40)"
::= { xdslAlmQueueEntry 2 }
xdslAlmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { xdslAlmQueueEntry 3 }
--
-- Alarm Status Table
--
xdslAlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: xdslAlmStatusUnitIndex "
::= { mdsl-card 10 }
xdslAlmStatusEntry OBJECT-TYPE
SYNTAX XdslAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex ,
xdslAlmStatusNumber }
::= { xdslAlmStatusTable 1 }
XdslAlmStatusEntry ::= SEQUENCE {
xdslAlmStatusNumber INTEGER (1..40),
xdslAlmStatusString DisplayString,
xdslAlmStatusThreshold INTEGER,
xdslAlmStatusState INTEGER,
xdslAlmStatusCount INTEGER,
xdslAlmStatusEnable AlarmSeverity
}
xdslAlmStatusNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Status Index "
::= { xdslAlmStatusEntry 2 }
xdslAlmStatusString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { xdslAlmStatusEntry 3 }
xdslAlmStatusThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm Threshold Value "
::= { xdslAlmStatusEntry 4 }
xdslAlmStatusState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { xdslAlmStatusEntry 5 }
xdslAlmStatusCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { xdslAlmStatusEntry 6 }
xdslAlmStatusEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { xdslAlmStatusEntry 7 }
--
-- Remote Router Table
--
xdslRouterConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslRtrConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Remote Router Configuration "
::= { mdsl-card 11 }
xdslRtrConfigEntry OBJECT-TYPE
SYNTAX XdslRtrConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslRtrUnitIndex ,
xdslRtrPortIndex }
::= { xdslRouterConfigTable 1 }
XdslRtrConfigTableEntry ::= SEQUENCE {
xdslRtrUnitIndex LargeSlotIndex,
xdslRtrPortIndex ThreePortID,
xdslRtrNetIP IpAddress,
xdslRtrNetMask IpAddress,
xdslRtrWanIP IpAddress,
xdslRtrWanMask IpAddress,
xdslRtrGatewayIP IpAddress,
xdslRtrMode INTEGER
}
xdslRtrUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { xdslRtrConfigEntry 1 }
xdslRtrPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~3, total 3 ports."
::= { xdslRtrConfigEntry 2 }
xdslRtrNetIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Net Address"
::= { xdslRtrConfigEntry 3 }
xdslRtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Net mask"
::= { xdslRtrConfigEntry 4 }
xdslRtrWanIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router WAN Address"
::= { xdslRtrConfigEntry 5 }
xdslRtrWanMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router WAN mask"
::= { xdslRtrConfigEntry 6 }
xdslRtrGatewayIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Gateway Address"
::= { xdslRtrConfigEntry 7 }
xdslRtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Mode(router or bridge)"
::= { xdslRtrConfigEntry 8 }
--
-- xdsl Status Config Table
--
xdslStatusConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslStatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" xdsl Status Config Configuration "
::= { mdsl-card 12 }
xdslStatusConfigEntry OBJECT-TYPE
SYNTAX XdslStatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { xdslIndex ,
xdslPortIndex }
::= { xdslStatusConfigTable 1 }
XdslStatusConfigTableEntry ::= SEQUENCE {
xdsle1SYNC INTEGER,
xdsle1TxAIS INTEGER,
xdsle1TxRAI INTEGER,
xdsle1RxAIS INTEGER,
xdsle1RxRAI INTEGER,
xdsle1LOS INTEGER,
xdsle1LOF INTEGER,
xdsldteDSR INTEGER,
xdsldteCTS INTEGER,
xdsldteDCD INTEGER,
xdsldteDTR INTEGER,
xdsldteRTS INTEGER
}
xdsle1SYNC OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line status."
::= { xdslStatusConfigEntry 1 }
xdsle1TxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line Tx Alarm Indication Signal."
::= { xdslStatusConfigEntry 2 }
xdsle1TxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line Tx Remote Alarm Indication."
::= { xdslStatusConfigEntry 3 }
xdsle1RxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line Rx Alarm Indication Signal."
::= { xdslStatusConfigEntry 4 }
xdsle1RxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line Rx Remote Alarm Indication."
::= { xdslStatusConfigEntry 5 }
xdsle1LOS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line LOS Status."
::= { xdslStatusConfigEntry 6 }
xdsle1LOF OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl e1 line LOF Status."
::= { xdslStatusConfigEntry 7 }
xdsldteDSR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl dte line DSR Status."
::= { xdslStatusConfigEntry 8 }
xdsldteCTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl dte line CTS Status."
::= { xdslStatusConfigEntry 9 }
xdsldteDCD OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl dte line DCD Status."
::= { xdslStatusConfigEntry 10 }
xdsldteDTR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl dte line DTR Status."
::= { xdslStatusConfigEntry 11 }
xdsldteRTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" xdsl dte line RTS Status."
::= { xdslStatusConfigEntry 12 }
--
-- Seven Days Performance Table
--
xdslSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { mdsl-card 13 }
xdslSevenDaysPerfEntry OBJECT-TYPE
SYNTAX XdslSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance entry"
INDEX { xdslIndex ,
xdslPortIndex ,
xdslDaysPerfTypeIndex ,
xdslDaysIndex }
::= { xdslSevenDaysPerfTable 1 }
XdslSevenDaysPerfEntry ::= SEQUENCE {
xdslDaysPerfTypeIndex INTEGER,
xdslDaysIndex INTEGER (1..7),
xdslDateStrIndex DisplayString (SIZE (0..255) ),
xdslSevenDaysPerfES INTEGER,
xdslSevenDaysPerfSES INTEGER,
xdslSevenDaysPerfUAS INTEGER
}
xdslDaysPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { xdslSevenDaysPerfEntry 3 }
xdslDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { xdslSevenDaysPerfEntry 4 }
xdslDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { xdslSevenDaysPerfEntry 5 }
xdslSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { xdslSevenDaysPerfEntry 6 }
xdslSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { xdslSevenDaysPerfEntry 7 }
xdslSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { xdslSevenDaysPerfEntry 8 }
--
-- Command Control Table
--
xdslCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF XdslCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { mdsl-card 14 }
xdslCommandControlEntry OBJECT-TYPE
SYNTAX XdslCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { xdslIndex ,
xdslPortIndex }
::= { xdslCommandControlTable 1 }
XdslCommandControlEntry ::= SEQUENCE {
xdslUnitReset INTEGER,
xdslPortLoadDefault INTEGER
}
xdslUnitReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Unit"
::= { xdslCommandControlEntry 1 }
xdslPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Port Load Default"
::= { xdslCommandControlEntry 2 }
mdslTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of MDSL"
::= { mdsl-card 100 }
--======================================================================--
--======================================================================--
-- dtu6-card MIB
--======================================================================--
--======================================================================--
--
-- DTU Command Control Table
--
dtu6CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU command control table."
::= { dtu6-card 1 }
dtu6CommandControlEntry OBJECT-TYPE
SYNTAX Dtu6CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU command control table."
INDEX { dtu6CommandSlotIndex , dtu6CommandPortIndex }
::= { dtu6CommandControlTable 1 }
Dtu6CommandControlEntry ::= SEQUENCE {
dtu6CommandSlotIndex LargeSlotIndex,
dtu6CommandPortIndex SixPortID,
dtu6ClearPerformanceData INTEGER,
dtu6PortReset INTEGER,
dtu6PortClearCRC INTEGER,
dtu6CardReset INTEGER
}
dtu6CommandSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6CommandControlEntry 1 }
dtu6CommandPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-6"
::= { dtu6CommandControlEntry 2 }
dtu6ClearPerformanceData OBJECT-TYPE
SYNTAX INTEGER {
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear DTU performance data"
::= { dtu6CommandControlEntry 3 }
dtu6PortReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTU port"
::= { dtu6CommandControlEntry 4 }
dtu6PortClearCRC OBJECT-TYPE
SYNTAX INTEGER {
clear-local-crc(1),
clear-remote-crc(2),
clear-all-port-crc(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear DTU port CRC Error Counter."
::= { dtu6CommandControlEntry 5 }
dtu6CardReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTU Card"
::= { dtu6CommandControlEntry 6 }
--
-- Remote DTE Config Table
--
dtu6RdteConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RdteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU remote DTE configuration."
::= { dtu6-card 2 }
dtu6RdteConfigEntry OBJECT-TYPE
SYNTAX Dtu6RdteConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU remote DTE configuration."
INDEX { dtu6RdteSlotIndex , dtu6RdtePortIndex }
::= { dtu6RdteConfigTable 1 }
Dtu6RdteConfigEntry ::= SEQUENCE {
dtu6RdteSlotIndex LargeSlotIndex,
dtu6RdtePortIndex SixPortID,
dtu6SyncMode INTEGER,
dtu6RdteSpeed INTEGER,
dtu6RdteChannel INTEGER,
dtu6RdteClock INTEGER,
dtu6RdteData INTEGER,
dtu6RdteRTS INTEGER,
dtu6RdteTTM INTEGER,
dtu6RdteInterface INTEGER,
dtu6RdteX50IdleCode INTEGER,
dtu6RdteX50Map DisplayString,
dtu6RdteX50Status DisplayString
}
dtu6RdteSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RdteConfigEntry 1 }
dtu6RdtePortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-6"
::= { dtu6RdteConfigEntry 2 }
dtu6SyncMode OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
async(2),
async-8(3),
async-9(4),
async-10(5),
async-11(6),
n-a(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote SYNC mode"
::= { dtu6RdteConfigEntry 3 }
dtu6RdteSpeed OBJECT-TYPE
SYNTAX INTEGER {
nx64K(1),
nx56K(2),
nx128K(3),
nx112K(4),
nx0K(5),
nx1-2K(6),
nx2-4K(7),
nx4-8K(8),
nx9-6K(9),
nx19-2K(10),
nx38-4K(11),
nx48-0K(12),
-- async1-2K(13),
-- async2-4K(14),
-- async4-8K(15),
-- async9-6K(16),
-- async19-2K(17),
-- async38-4K(18),
n-a(13)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE Speed"
::= { dtu6RdteConfigEntry 4 }
dtu6RdteChannel OBJECT-TYPE
SYNTAX INTEGER {
iDLE(1),
b1(2),
b2(3),
b1-b2(4),
n-a(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE channel"
::= { dtu6RdteConfigEntry 5 }
dtu6RdteClock OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE clock type"
::= { dtu6RdteConfigEntry 6 }
dtu6RdteData OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE data type"
::= { dtu6RdteConfigEntry 7 }
dtu6RdteRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE RTS type"
::= { dtu6RdteConfigEntry 8 }
dtu6RdteTTM OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
n-a(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE TTM type"
::= { dtu6RdteConfigEntry 9 }
dtu6RdteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
rs449-eia530(2),
x21(3),
rs232(4),
rs232-SubRate(8),
g-703(11),
na(16),
other(18),
router(20),
rs232-x50(24)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote DTE card interface"
::= { dtu6RdteConfigEntry 10 }
dtu6RdteX50IdleCode OBJECT-TYPE
SYNTAX INTEGER (0..47)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 idle code"
::= { dtu6RdteConfigEntry 11 }
dtu6RdteX50Map OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..21) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 Map"
::= { dtu6RdteConfigEntry 12 }
dtu6RdteX50Status OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..21) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote DTE card X50 Status"
::= { dtu6RdteConfigEntry 13 }
--
-- Diagnostic Control Table
--
dtu6DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU diagnostics control table."
::= { dtu6-card 3 }
dtu6DiagControlEntry OBJECT-TYPE
SYNTAX Dtu6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU diagnostics control table."
INDEX { dtu6DiagSlotIndex , dtu6DiagPortIndex }
::= { dtu6DiagControlTable 1 }
Dtu6DiagControlEntry ::= SEQUENCE {
dtu6DiagSlotIndex LargeSlotIndex,
dtu6DiagPortIndex SixPortID,
dtu6NearLoopback INTEGER,
dtu6RemoteLoopback INTEGER,
dtu6BertControl INTEGER,
dtu6BertStatus INTEGER,
dtu6QrssElapseSeconds INTEGER,
dtu6QrssErrorSeconds INTEGER,
dtu6QrssErrorBits INTEGER,
dtu6RemBertControl INTEGER,
dtu6RemBertStatus INTEGER,
dtu6RemQrssElapseSeconds INTEGER,
dtu6RemQrssErrorSeconds INTEGER,
dtu6RemQrssErrorBits INTEGER,
dtu6RemQrssPatternUnsyncSeconds INTEGER
}
dtu6DiagSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6DiagControlEntry 1 }
dtu6DiagPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-6"
::= { dtu6DiagControlEntry 2 }
dtu6NearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payLoadLoopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Near loopback type"
::= { dtu6DiagControlEntry 3 }
dtu6RemoteLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
remotePayLoad(2),
remoteDTE-or-remoteROUTER(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote loopback type"
::= { dtu6DiagControlEntry 4 }
dtu6BertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-ON(2),
reset(3),
inject-Error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT control"
::= { dtu6DiagControlEntry 5 }
dtu6BertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-Sync(1),
bert-Unsync(2),
bert-Not-Active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { dtu6DiagControlEntry 6 }
dtu6QrssElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss elapse seconds"
::= { dtu6DiagControlEntry 7 }
dtu6QrssErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error seconds"
::= { dtu6DiagControlEntry 8 }
dtu6QrssErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error bits"
::= { dtu6DiagControlEntry 9 }
dtu6RemBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-FULL(2),
bert-DTE1(3),
-- bert-DTE2(4),
reset(5),
inject-Error(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT control"
::= { dtu6DiagControlEntry 10 }
dtu6RemBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-Sync(1),
bert-Unsync(2),
bert-Not-Active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { dtu6DiagControlEntry 11 }
dtu6RemQrssElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss elapse seconds"
::= { dtu6DiagControlEntry 12 }
dtu6RemQrssErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error seconds"
::= { dtu6DiagControlEntry 13 }
dtu6RemQrssErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss error bits"
::= { dtu6DiagControlEntry 14 }
dtu6RemQrssPatternUnsyncSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Qrss pattern unsync seconds"
::= { dtu6DiagControlEntry 15 }
--
-- Alarm History Table
--
dtu6AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The dtu6 alarm history table."
::= { dtu6-card 4 }
dtu6AlarmHistoryEntry OBJECT-TYPE
SYNTAX Dtu6AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU alarm history table."
INDEX { dtu6AlmhisSlotIndex , dtu6AlmhisPortIndex }
::= { dtu6AlarmHistoryTable 1 }
Dtu6AlarmHistoryEntry ::= SEQUENCE {
dtu6AlmhisSlotIndex LargeSlotIndex,
dtu6AlmhisPortIndex SixPortID,
dtu6UnsyncAlarmState INTEGER,
dtu6UnsyncAlarmCount INTEGER
}
dtu6AlmhisSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6AlarmHistoryEntry 1 }
dtu6AlmhisPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6AlarmHistoryEntry 2 }
dtu6UnsyncAlarmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm history : unsync alarm state"
::= { dtu6AlarmHistoryEntry 3 }
dtu6UnsyncAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm history : unsync alarm count"
::= { dtu6AlarmHistoryEntry 4 }
--
-- Alarm Control Table
--
dtu6AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU alarm control table."
::= { dtu6-card 5 }
dtu6AlarmControlEntry OBJECT-TYPE
SYNTAX Dtu6AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU alarm control table."
INDEX { dtu6AlarmSlotIndex , dtu6AlarmPortIndex }
::= { dtu6AlarmControlTable 1 }
Dtu6AlarmControlEntry ::= SEQUENCE {
dtu6AlarmSlotIndex LargeSlotIndex,
dtu6AlarmPortIndex SixPortID,
dtu6LineUnsync AlarmSeverity
}
dtu6AlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6AlarmControlEntry 1 }
dtu6AlarmPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6AlarmControlEntry 2 }
dtu6LineUnsync OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm : Line Unsync"
::= { dtu6AlarmControlEntry 3 }
--
-- Current Line Performance Table
--
dtu6CurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU current line performance table."
::= { dtu6-card 6 }
dtu6CurrentPerfEntry OBJECT-TYPE
SYNTAX Dtu6CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU current line performance table."
INDEX { dtu6CurrSlotIndex , dtu6CurrPortIndex }
::= { dtu6CurrentPerfTable 1 }
Dtu6CurrentPerfEntry ::= SEQUENCE {
dtu6CurrSlotIndex LargeSlotIndex,
dtu6CurrPortIndex SixPortID,
dtu6CurrentAS INTEGER,
dtu6CurrentUAS INTEGER,
dtu6Current24hAS INTEGER,
dtu6Current24hUAS INTEGER,
dtu6Valid15minInterval INTEGER,
dtu6Valid1dayInterval INTEGER
}
dtu6CurrSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6CurrentPerfEntry 1 }
dtu6CurrPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6CurrentPerfEntry 2 }
dtu6CurrentAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"15m Performance available seconds"
::= { dtu6CurrentPerfEntry 3 }
dtu6CurrentUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"15m Performance unavailable seconds"
::= { dtu6CurrentPerfEntry 4 }
dtu6Current24hAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24h Performance available seconds"
::= { dtu6CurrentPerfEntry 5 }
dtu6Current24hUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"24h Performance unavailable seconds"
::= { dtu6CurrentPerfEntry 6 }
dtu6Valid15minInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Valid 15 minutes Interval number"
::= { dtu6CurrentPerfEntry 7 }
dtu6Valid1dayInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Valid 1 day Interval number"
::= { dtu6CurrentPerfEntry 8 }
--
-- Interval Line Performance Table
--
dtu6IntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6IntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU interval line performance table."
::= { dtu6-card 7 }
dtu6IntervalPerfEntry OBJECT-TYPE
SYNTAX Dtu6IntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU interval line performance table."
INDEX { dtu6PerfSlotIndex ,
dtu6PerfPortIndex ,
dtu6ItvIndex }
::= { dtu6IntervalPerfTable 1 }
Dtu6IntervalPerfEntry ::= SEQUENCE {
dtu6PerfSlotIndex LargeSlotIndex,
dtu6PerfPortIndex SixPortID,
dtu6ItvIndex INTEGER,
dtu6IntervalAS INTEGER,
dtu6IntervalUAS INTEGER
}
dtu6PerfSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6IntervalPerfEntry 1 }
dtu6PerfPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6IntervalPerfEntry 2 }
dtu6ItvIndex OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance interval index"
::= { dtu6IntervalPerfEntry 3 }
dtu6IntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance available seconds"
::= { dtu6IntervalPerfEntry 4 }
dtu6IntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance unavailable seconds"
::= { dtu6IntervalPerfEntry 5 }
--
-- Total Line Performance Table
--
dtu6TotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU total line performance table."
::= { dtu6-card 8 }
dtu6TotalPerfEntry OBJECT-TYPE
SYNTAX Dtu6TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU total line performance table."
INDEX { dtu6TPerfSlotIndex ,
dtu6TPerfPortIndex ,
dtu6TotalIndex }
::= { dtu6TotalPerfTable 1 }
Dtu6TotalPerfEntry ::= SEQUENCE {
dtu6TPerfSlotIndex LargeSlotIndex,
dtu6TPerfPortIndex SixPortID,
dtu6TotalIndex INTEGER,
dtu6TotalAS INTEGER,
dtu6TotalUAS INTEGER
}
dtu6TPerfSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6TotalPerfEntry 1 }
dtu6TPerfPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6TotalPerfEntry 2 }
dtu6TotalIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance interval index"
::= { dtu6TotalPerfEntry 3 }
dtu6TotalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day performance available seconds"
::= { dtu6TotalPerfEntry 4 }
dtu6TotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Day performance unavailable seconds"
::= { dtu6TotalPerfEntry 5 }
--
-- LED Status Table
--
dtu6RemLedStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RemLedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTU remote LED status table."
::= { dtu6-card 9 }
dtu6RemLedStatusEntry OBJECT-TYPE
SYNTAX Dtu6RemLedStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LED status entry"
INDEX { dtu6LedSlotIndex , dtu6LedPortIndex }
::= { dtu6RemLedStatusTable 1 }
Dtu6RemLedStatusEntry ::= SEQUENCE {
dtu6LedSlotIndex LargeSlotIndex,
dtu6LedPortIndex SixPortID,
dtu6LedColor INTEGER
}
dtu6LedSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RemLedStatusEntry 1 }
dtu6LedPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6RemLedStatusEntry 2 }
dtu6LedColor OBJECT-TYPE
SYNTAX INTEGER {
none(0),
off(1),
red(2),
green(3),
flashing-green(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Led Color"
::= { dtu6RemLedStatusEntry 3 }
--
-- DTU Line Config Table
--
dtu6LineConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU line configuration."
::= { dtu6-card 10 }
dtu6LineConfigEntry OBJECT-TYPE
SYNTAX Dtu6LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU line configuration."
INDEX { dtu6ConfigSlotIndex , dtu6ConfigPortIndex }
::= { dtu6LineConfigTable 1 }
Dtu6LineConfigEntry ::= SEQUENCE {
dtu6ConfigSlotIndex LargeSlotIndex,
dtu6ConfigPortIndex SixPortID,
dtu6LineMode INTEGER,
dtu6LineProtocol INTEGER,
dtu6ClockSource INTEGER
}
dtu6ConfigSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6LineConfigEntry 1 }
dtu6ConfigPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port 1-6"
::= { dtu6LineConfigEntry 2 }
dtu6LineMode OBJECT-TYPE
SYNTAX INTEGER {
lT(1),
nT(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU Line Mode"
::= { dtu6LineConfigEntry 3 }
dtu6LineProtocol OBJECT-TYPE
SYNTAX INTEGER {
d-channel(1),
m-channel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU Line protocol channel"
::= { dtu6LineConfigEntry 4 }
dtu6ClockSource OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
dTE-1(2),
dTE-2(3),
line(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU master clock source"
::= { dtu6LineConfigEntry 5 }
--
-- 15 minutes Interval Performance Table
--
dtu6-15minIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6-15minIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU 15 minutes interval performance table."
::= { dtu6-card 17 }
dtu6-15minIntervalPerfEntry OBJECT-TYPE
SYNTAX Dtu6-15minIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU 15 minutes interval performance table."
INDEX { dtu6PerfSlotIndex ,
dtu6PerfPortIndex ,
dtu6ItvIndex }
::= { dtu6-15minIntervalPerfTable 1 }
Dtu6-15minIntervalPerfEntry ::= SEQUENCE {
dtu6-15minIntervalAS INTEGER,
dtu6-15minIntervalUAS INTEGER
}
dtu6-15minIntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Available Seconds"
::= { dtu6-15minIntervalPerfEntry 4 }
dtu6-15minIntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UnAvailable Seconds"
::= { dtu6-15minIntervalPerfEntry 5 }
--
-- 1 Day Interval Performance Table
--
dtu6-1dayIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6-1dayIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTU total line performance table."
::= { dtu6-card 18 }
dtu6-1dayIntervalPerfEntry OBJECT-TYPE
SYNTAX Dtu6-1dayIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU total line performance table."
INDEX { dtu6TPerfSlotIndex ,
dtu6TPerfPortIndex ,
dtu6TotalIndex }
::= { dtu6-1dayIntervalPerfTable 1 }
Dtu6-1dayIntervalPerfEntry ::= SEQUENCE {
dtu6-1dayIntervalAS INTEGER,
dtu6-1dayIntervalUAS INTEGER
}
dtu6-1dayIntervalAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Available Seconds"
::= { dtu6-1dayIntervalPerfEntry 4 }
dtu6-1dayIntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UnAvailable Seconds"
::= { dtu6-1dayIntervalPerfEntry 5 }
--
-- Remote Router Table
--
dtu6RouterConfig OBJECT IDENTIFIER ::= { dtu6-card 11 }
--
-- NI Control Table
--
dtu6RtrNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Table"
::= { dtu6RouterConfig 1 }
dtu6RouterNiControlEntry OBJECT-TYPE
SYNTAX Dtu6RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Entry"
INDEX { dtu6RtrNiUnitIndex ,
dtu6RtrNiPortIndex ,
dtu6RtrNiIndex }
::= { dtu6RtrNiControlTable 1 }
Dtu6RtrNiControlEntry ::= SEQUENCE {
dtu6RtrNiUnitIndex LargeSlotIndex,
dtu6RtrNiPortIndex SixPortID,
dtu6RtrNiIndex INTEGER,
dtu6RtrIPAddr IpAddress,
dtu6RtrSubnetMask IpAddress,
dtu6RtrFrame INTEGER,
dtu6RtrRIP1 INTEGER,
dtu6RtrRIP2 INTEGER,
dtu6RtrMode INTEGER
}
dtu6RtrNiUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RouterNiControlEntry 1 }
dtu6RtrNiPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~6, total 6 ports."
::= { dtu6RouterNiControlEntry 2 }
dtu6RtrNiIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2),
wan2(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Ni index"
::= { dtu6RouterNiControlEntry 3 }
dtu6RtrIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR IP Address"
::= { dtu6RouterNiControlEntry 4 }
dtu6RtrSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR net mask"
::= { dtu6RouterNiControlEntry 5 }
dtu6RtrFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
ethernet(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Layer2 frame"
::= { dtu6RouterNiControlEntry 6 }
dtu6RtrRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP1"
::= { dtu6RouterNiControlEntry 7 }
dtu6RtrRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP2"
::= { dtu6RouterNiControlEntry 8 }
dtu6RtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR mode"
::= { dtu6RouterNiControlEntry 9 }
--
-- Route Table
--
dtu6RtrRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Table"
::= { dtu6RouterConfig 2 }
dtu6RouterRouteControlEntry OBJECT-TYPE
SYNTAX Dtu6RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Entry"
INDEX { dtu6RtrRUnitIndex ,
dtu6RtrRPortIndex ,
dtu6RtrEntry }
::= { dtu6RtrRouteControlTable 1 }
Dtu6RtrRouteControlEntry ::= SEQUENCE {
dtu6RtrRUnitIndex LargeSlotIndex,
dtu6RtrRPortIndex SixPortID,
dtu6RtrEntry INTEGER (1..16),
dtu6RtrNetAddr IpAddress,
dtu6RtrNetMask IpAddress,
dtu6RtrGatewayAddr IpAddress,
dtu6RtrNIAddr IpAddress,
dtu6RtrMetric INTEGER
}
dtu6RtrRUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RouterRouteControlEntry 1 }
dtu6RtrRPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~6, total 6 ports."
::= { dtu6RouterRouteControlEntry 2 }
dtu6RtrEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Route Entry"
::= { dtu6RouterRouteControlEntry 3 }
dtu6RtrNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net Address"
::= { dtu6RouterRouteControlEntry 4 }
dtu6RtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net mask"
::= { dtu6RouterRouteControlEntry 5 }
dtu6RtrGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route gateway Address"
::= { dtu6RouterRouteControlEntry 6 }
dtu6RtrNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route NI Address"
::= { dtu6RouterRouteControlEntry 7 }
dtu6RtrMetric OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Route metric"
::= { dtu6RouterRouteControlEntry 8 }
--
-- Router Command
--
dtu6RtrCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command(reset & load-default) Table"
::= { dtu6RouterConfig 3 }
dtu6RtrCommandEntry OBJECT-TYPE
SYNTAX Dtu6RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Entry"
INDEX { dtu6RtrCmdUnitIndex ,
dtu6RtrCmdPortIndex }
::= { dtu6RtrCommandTable 1 }
Dtu6RtrCmdEntry ::= SEQUENCE {
dtu6RtrCmdUnitIndex LargeSlotIndex,
dtu6RtrCmdPortIndex SixPortID,
dtu6RtrCommand INTEGER
}
dtu6RtrCmdUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RtrCommandEntry 1 }
dtu6RtrCmdPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~6, total 6 ports."
::= { dtu6RtrCommandEntry 2 }
dtu6RtrCommand OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
load-default(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Command(reset or load-default)"
::= { dtu6RtrCommandEntry 3 }
--
-- Router Map
--
dtu6RtrMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Table"
::= { dtu6RouterConfig 4 }
dtu6RtrMapEntry OBJECT-TYPE
SYNTAX Dtu6RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Entry"
INDEX { dtu6RtrMapUnitIndex ,
dtu6RtrMapPortIndex }
::= { dtu6RtrMapTable 1 }
Dtu6RtrMappingEntry ::= SEQUENCE {
dtu6RtrMapUnitIndex LargeSlotIndex,
dtu6RtrMapPortIndex SixPortID,
dtu6RtrChB1 INTEGER,
dtu6RtrChB2 INTEGER
}
dtu6RtrMapUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RtrMapEntry 1 }
dtu6RtrMapPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~6, total 6 ports."
::= { dtu6RtrMapEntry 2 }
dtu6RtrChB1 OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
wan2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" U channel B1 map data"
::= { dtu6RtrMapEntry 3 }
dtu6RtrChB2 OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
wan2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" U channel B2 map data"
::= { dtu6RtrMapEntry 4 }
--
-- DTU Remote DTU Information Table
--
dtu6RemoteDTUInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6RemoteDTUInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote DTU Information Table."
::= { dtu6-card 12 }
dtu6RemoteDTUInfoEntry OBJECT-TYPE
SYNTAX Dtu6RemoteDTUInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Remote DTU Information Table."
INDEX { dtu6RemoteDTUInfoSlotIndex ,
dtu6RemoteDTUInfoPortIndex }
::= { dtu6RemoteDTUInfoTable 1 }
Dtu6RemoteDTUInfoEntry ::= SEQUENCE {
dtu6RemoteDTUInfoSlotIndex LargeSlotIndex,
dtu6RemoteDTUInfoPortIndex SixPortID,
dtu6RemoteDTUInfoDate DisplayString,
dtu6RemoteDTUInfoSerialNumber DisplayString,
dtu6RemoteDTUInfoSWVersion DisplayString,
dtu6RemoteDTUInfoConfiguration DisplayString
}
dtu6RemoteDTUInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6RemoteDTUInfoEntry 1 }
dtu6RemoteDTUInfoPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-6"
::= { dtu6RemoteDTUInfoEntry 2 }
dtu6RemoteDTUInfoDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote DTU Date "
::= { dtu6RemoteDTUInfoEntry 3 }
dtu6RemoteDTUInfoSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Serial Number"
::= { dtu6RemoteDTUInfoEntry 4 }
dtu6RemoteDTUInfoSWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Software Version"
::= { dtu6RemoteDTUInfoEntry 5 }
dtu6RemoteDTUInfoConfiguration OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Configuration"
::= { dtu6RemoteDTUInfoEntry 6 }
--
-- DTU6 Line Status Table
--
dtu6LineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dtu6LineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTU line status table."
::= { dtu6-card 13 }
dtu6LineStatusEntry OBJECT-TYPE
SYNTAX Dtu6LineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTU line status table."
INDEX { dtu6LineStatusSlotIndex ,
dtu6LineStatusPortIndex }
::= { dtu6LineStatusTable 1 }
Dtu6LineStatusEntry ::= SEQUENCE {
dtu6LineStatusSlotIndex LargeSlotIndex,
dtu6LineStatusPortIndex SixPortID,
dtu6LineLocalCRC INTEGER,
dtu6LineLocalIntervalAVG DisplayString,
dtu6LineRemoteCRC INTEGER,
dtu6LineRemoteIntervalAVG DisplayString
}
dtu6LineStatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dtu6LineStatusEntry 1 }
dtu6LineStatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU sport 1-10"
::= { dtu6LineStatusEntry 2 }
dtu6LineLocalCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port Local CRC Error."
::= { dtu6LineStatusEntry 3 }
dtu6LineLocalIntervalAVG OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTU port local CRC Interval Average."
::= { dtu6LineStatusEntry 4 }
dtu6LineRemoteCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTU port Remote CRC Error."
::= { dtu6LineStatusEntry 5 }
dtu6LineRemoteIntervalAVG OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTU port remote CRC Interval Average."
::= { dtu6LineStatusEntry 6 }
dtu6TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of DTU6"
::= { dtu6-card 100 }
--======================================================================--
--======================================================================--
-- em-card MIB
--======================================================================--
-- E&M Card
-- emConfigControlTable OBJECT IDENTIFIER ::= { em-card 1 }
-- emDiagControlTable OBJECT IDENTIFIER ::= { em-card 3 }
-- emCommandControlTable OBJECT IDENTIFIER ::= { em-card 4 }
-- emAllPortConfigControlTable OBJECT IDENTIFIER ::= { em-card 5 }
-- emPerPortConfigControlTable OBJECT IDENTIFIER ::= { em-card 6 }
-- emALLPortSigConfigControlTable OBJECT IDENTIFIER ::= { em-card 7 }
--======================================================================--
EMGain ::= INTEGER {
gain-neg-16-0-db(1),
gain-neg-15-5-db(2),
gain-neg-15-0-db(3),
gain-neg-14-5-db(4),
gain-neg-14-0-db(5),
gain-neg-13-5-db(6),
gain-neg-13-0-db(7),
gain-neg-12-5-db(8),
gain-neg-12-0-db(9),
gain-neg-11-5-db(10),
gain-neg-11-0-db(11),
gain-neg-10-5-db(12),
gain-neg-10-0-db(13),
gain-neg-9-5-db(14),
gain-neg-9-0-db(15),
gain-neg-8-5-db(16),
gain-neg-8-0-db(17),
gain-neg-7-5-db(18),
gain-neg-7-0-db(19),
gain-neg-6-5-db(20),
gain-neg-6-0-db(21),
gain-neg-5-5-db(22),
gain-neg-5-0-db(23),
gain-neg-4-5-db(24),
gain-neg-4-0-db(25),
gain-neg-3-5-db(26),
gain-neg-3-0-db(27),
gain-neg-2-5-db(28),
gain-neg-2-0-db(29),
gain-neg-1-5-db(30),
gain-neg-1-0-db(31),
gain-neg-0-5-db(32),
gain-0-0-db(33),
gain-0-5-db(34),
gain-1-0-db(35),
gain-1-5-db(36),
gain-2-0-db(37),
gain-2-5-db(38),
gain-3-0-db(39),
gain-3-5-db(40),
gain-4-0-db(41),
gain-4-5-db(42),
gain-5-0-db(43),
gain-5-5-db(44),
gain-6-0-db(45),
gain-6-5-db(46),
gain-7-0-db(47),
not-available(255)
}
--
-- EM Control Table
--
emConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Configuration Control Table"
::= { em-card 1 }
emConfigControlEntry OBJECT-TYPE
SYNTAX EmConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&m configuration control entry"
INDEX { emConfigControlIndex }
::= { emConfigControlTable 1 }
EmConfigControlEntry ::= SEQUENCE {
emConfigControlIndex LargeSlotIndex,
emConfigControlSide INTEGER,
emConfigControlLine INTEGER,
emConfigControlImpedance INTEGER,
emConfigControlSignaling INTEGER,
-- emConfigControlAB-bit
-- INTEGER,
emConfigControlA-u-law INTEGER,
emConfigControlTx-gain EMGain,
emConfigControlRx-gain EMGain,
emConfigControlHW-SW-Control INTEGER
}
emConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emConfigControlEntry 1 }
emConfigControlSide OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
-- a-b(3),
error(4),
not-available(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M Side "
::= { emConfigControlEntry 2 }
emConfigControlLine OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2),
not-available(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { emConfigControlEntry 3 }
emConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2),
not-available(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { emConfigControlEntry 4 }
emConfigControlSignaling OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7),
not-available(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { emConfigControlEntry 5 }
-- emConfigControlAB-bit OBJECT-TYPE
-- SYNTAX INTEGER {
-- normal(1),
-- invert(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " AB-BIT "
-- ::= { emConfigControlEntry 6 }
emConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2),
not-available(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { emConfigControlEntry 7 }
emConfigControlTx-gain OBJECT-TYPE
SYNTAX EMGain
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TX-GAIN "
::= { emConfigControlEntry 8 }
emConfigControlRx-gain OBJECT-TYPE
SYNTAX EMGain
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RX-GAIN "
::= { emConfigControlEntry 9 }
emConfigControlHW-SW-Control OBJECT-TYPE
SYNTAX INTEGER {
hw-control(1),
sw-control(2),
not-available(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M HW/SW Control Mode "
::= { emConfigControlEntry 10 }
--
-- Line Diagnostic Control Table
--
emDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Diagnostic Control Table."
::= { em-card 3 }
emDiagControlEntry OBJECT-TYPE
SYNTAX EmDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of E&M diagnostic control table."
INDEX { emDiagControlIndex }
::= { emDiagControlTable 1 }
EmDiagControlEntry ::= SEQUENCE {
emDiagControlIndex LargeSlotIndex,
emDiagControlTEST INTEGER,
emDiagControlE1 EMOffOn,
emDiagControlE2 EMOffOn,
emDiagControlE3 EMOffOn,
emDiagControlE4 EMOffOn,
emDiagControlE5 EMOffOn,
emDiagControlE6 EMOffOn,
emDiagControlE7 EMOffOn,
emDiagControlE8 EMOffOn,
emDiagControlM1 EMOffOn,
emDiagControlM2 EMOffOn,
emDiagControlM3 EMOffOn,
emDiagControlM4 EMOffOn,
emDiagControlM5 EMOffOn,
emDiagControlM6 EMOffOn,
emDiagControlM7 EMOffOn,
emDiagControlM8 EMOffOn,
emDiagControl-48V-Power INTEGER,
emUpLinkStatus INTEGER,
emTestButton INTEGER
}
emDiagControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emDiagControlEntry 1 }
emDiagControlTEST OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
start(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { emDiagControlEntry 2 }
emDiagControlE1 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E1"
::= { emDiagControlEntry 3 }
emDiagControlE2 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E2"
::= { emDiagControlEntry 4 }
emDiagControlE3 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E3"
::= { emDiagControlEntry 5 }
emDiagControlE4 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E4"
::= { emDiagControlEntry 6 }
emDiagControlE5 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E5"
::= { emDiagControlEntry 7 }
emDiagControlE6 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E6"
::= { emDiagControlEntry 8 }
emDiagControlE7 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E7"
::= { emDiagControlEntry 9 }
emDiagControlE8 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M E8"
::= { emDiagControlEntry 10 }
emDiagControlM1 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M1"
::= { emDiagControlEntry 11 }
emDiagControlM2 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M2"
::= { emDiagControlEntry 12 }
emDiagControlM3 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M3"
::= { emDiagControlEntry 13 }
emDiagControlM4 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M4"
::= { emDiagControlEntry 14 }
emDiagControlM5 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M5"
::= { emDiagControlEntry 15 }
emDiagControlM6 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M6"
::= { emDiagControlEntry 16 }
emDiagControlM7 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M7"
::= { emDiagControlEntry 17 }
emDiagControlM8 OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M M8"
::= { emDiagControlEntry 18 }
emDiagControl-48V-Power OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
failure(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"<V5.0: -48V Power OK/Failure
>V5.0: M,SB Lead 48V status"
::= { emDiagControlEntry 19 }
emUpLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
failure(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UpLink Status"
::= { emDiagControlEntry 20 }
emTestButton OBJECT-TYPE
SYNTAX INTEGER {
available(1),
unavailable(2),
old-version(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test button available"
::= { emDiagControlEntry 21 }
--
-- Command Control Table
--
emCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { em-card 4 }
emCommandControlEntry OBJECT-TYPE
SYNTAX EmCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { emCommandControlIndex }
::= { emCommandControlTable 1 }
EmCommandControlEntry ::= SEQUENCE {
emCommandControlIndex LargeSlotIndex,
emCommandControlReset INTEGER,
emCommandControlLoadDefault INTEGER
}
emCommandControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emCommandControlEntry 1 }
emCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default E&M CONF"
::= { emCommandControlEntry 2 }
emCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: E&M Card Reset"
::= { emCommandControlEntry 3 }
--
-- EM All Port Control Table
--
emAllPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M All Port Configuration Control Table"
::= { em-card 5 }
emAllPortConfigControlEntry OBJECT-TYPE
SYNTAX EmAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&m All Port configuration control entry"
INDEX { emAllPortConfigControlIndex }
::= { emAllPortConfigControlTable 1 }
EmAllPortConfigControlEntry ::= SEQUENCE {
emAllPortConfigControlIndex LargeSlotIndex,
emAllPortConfigControlSide INTEGER,
emAllPortConfigControlLine INTEGER,
emAllPortConfigControlImpedance INTEGER,
emAllPortConfigControlSignaling INTEGER,
emAllPortConfigControlA-u-law INTEGER,
emAllPortConfigControlHW-SW-Control INTEGER,
emAllPortConfigControlTrunk-Condition INTEGER
}
emAllPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emAllPortConfigControlEntry 1 }
emAllPortConfigControlSide OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M Side "
::= { emAllPortConfigControlEntry 2 }
emAllPortConfigControlLine OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { emAllPortConfigControlEntry 3 }
emAllPortConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { emAllPortConfigControlEntry 4 }
emAllPortConfigControlSignaling OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { emAllPortConfigControlEntry 5 }
emAllPortConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { emAllPortConfigControlEntry 7 }
emAllPortConfigControlHW-SW-Control OBJECT-TYPE
SYNTAX INTEGER {
hw-control(1),
sw-control(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M HW/SW Control Mode "
::= { emAllPortConfigControlEntry 8 }
emAllPortConfigControlTrunk-Condition OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { emAllPortConfigControlEntry 9 }
--
-- E&M Per Port Config Control Table
--
emPerPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Per Port Configuration Control Table"
::= { em-card 6 }
emPerPortConfigControlEntry OBJECT-TYPE
SYNTAX EmPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Per Port Configuration control entry"
INDEX { emPerPortConfigControlIndex ,
emPerPortConfigControlPortIndex }
::= { emPerPortConfigControlTable 1 }
EmPerPortConfigControlEntry ::= SEQUENCE {
emPerPortConfigControlIndex LargeSlotIndex,
emPerPortConfigControlPortIndex EightPortID,
-- emPerPortConfigControlPLAR
-- INTEGER,
emPerPortConfigControlTx-gain DisplayString,
emPerPortConfigControlRx-gain DisplayString
}
emPerPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emPerPortConfigControlEntry 1 }
emPerPortConfigControlPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { emPerPortConfigControlEntry 2 }
-- emPerPortConfigControlPLAR OBJECT-TYPE
-- SYNTAX INTEGER {
-- off(1),
-- on(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Per port PLAR setting "
-- ::= { emPerPortConfigControlEntry 3 }
emPerPortConfigControlTx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { emPerPortConfigControlEntry 4 }
emPerPortConfigControlRx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { emPerPortConfigControlEntry 5 }
--
-- E&M All Port Signaling Config Control Table
--
emALLPortSigConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M All Port Signaling Configuration Control Table"
::= { em-card 7 }
emAllPortSigConfigControlEntry OBJECT-TYPE
SYNTAX EmAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M all port signaling configuration control entry"
INDEX { emAllPortSigConfigControlIndex ,
emAllPortSigConfigControlItemIndex ,
emAllPortSigConfigControlSigBitIndex }
::= { emALLPortSigConfigControlTable 1 }
EmAllPortSigConfigControlEntry ::= SEQUENCE {
emAllPortSigConfigControlIndex LargeSlotIndex,
emAllPortSigConfigControlItemIndex INTEGER,
emAllPortSigConfigControlSigBitIndex INTEGER,
emAllPortSigConfigControlSigBit INTEGER
}
emAllPortSigConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emAllPortSigConfigControlEntry 1 }
emAllPortSigConfigControlItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-on-hook(1),
tx-off-hook(2),
rx-relay-open(3),
rx-relay-close(4),
tx-ring-back(5),
rx-oos-alm(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"on-hook, off-hook, relay-open, relay-close"
::= { emAllPortSigConfigControlEntry 2 }
emAllPortSigConfigControlSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { emAllPortSigConfigControlEntry 3 }
emAllPortSigConfigControlSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { emAllPortSigConfigControlEntry 4 }
--
-- EM6 All Port Control Table
--
em6AllPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6AllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M6 All Port Configuration Control Table"
::= { em-card 8 }
em6AllPortConfigControlEntry OBJECT-TYPE
SYNTAX Em6AllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&m6 All Port configuration control entry"
INDEX { em6AllPortConfigControlIndex }
::= { em6AllPortConfigControlTable 1 }
Em6AllPortConfigControlEntry ::= SEQUENCE {
em6AllPortConfigControlIndex LargeSlotIndex,
em6AllPortConfigControlSide14 INTEGER,
em6AllPortConfigControlSide58 INTEGER,
em6AllPortConfigControlLine INTEGER,
em6AllPortConfigControlImpedance INTEGER,
em6AllPortConfigControlSignaling INTEGER,
em6AllPortConfigControlA-u-law INTEGER,
em6AllPortConfigControlHW-SW-Control INTEGER,
em6AllPortConfigControlTrunk14 INTEGER,
em6AllPortConfigControlTrunk58 INTEGER,
em6AllPortConfigControlRingBackSW INTEGER,
em6AllPortConfigControlTestButton INTEGER
}
em6AllPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6AllPortConfigControlEntry 1 }
em6AllPortConfigControlSide14 OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M6 Side "
::= { em6AllPortConfigControlEntry 2 }
em6AllPortConfigControlSide58 OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M6 Side "
::= { em6AllPortConfigControlEntry 3 }
em6AllPortConfigControlLine OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { em6AllPortConfigControlEntry 4 }
em6AllPortConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { em6AllPortConfigControlEntry 5 }
em6AllPortConfigControlSignaling OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line "
::= { em6AllPortConfigControlEntry 6 }
em6AllPortConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { em6AllPortConfigControlEntry 7 }
em6AllPortConfigControlHW-SW-Control OBJECT-TYPE
SYNTAX INTEGER {
hw-control(1),
sw-control(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M HW/SW Control Mode "
::= { em6AllPortConfigControlEntry 8 }
em6AllPortConfigControlTrunk14 OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortConfigControlEntry 9 }
em6AllPortConfigControlTrunk58 OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortConfigControlEntry 10 }
em6AllPortConfigControlRingBackSW OBJECT-TYPE
SYNTAX INTEGER {
available(1),
unavailable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortConfigControlEntry 11 }
em6AllPortConfigControlTestButton OBJECT-TYPE
SYNTAX INTEGER {
available(1),
unavailable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortConfigControlEntry 12 }
--
-- E&M All Port Signaling Config Set Table
--
em6ALLPortSigConfigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6AllPortSigConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M All Port Signaling Configuration Set Table"
::= { em-card 9 }
em6AllPortSigConfigSetEntry OBJECT-TYPE
SYNTAX Em6AllPortSigConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M all port signaling configuration control entry"
INDEX { em6AllPortSigConfigSetIndex ,
em6AllPortSigConfigSetItemIndex ,
em6AllPortSigConfigSetSigBitIndex }
::= { em6ALLPortSigConfigSetTable 1 }
Em6AllPortSigConfigSetEntry ::= SEQUENCE {
em6AllPortSigConfigSetIndex LargeSlotIndex,
em6AllPortSigConfigSetItemIndex INTEGER,
em6AllPortSigConfigSetSigBitIndex INTEGER,
em6AllPortSigConfigSetSigBit INTEGER
}
em6AllPortSigConfigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6AllPortSigConfigSetEntry 1 }
em6AllPortSigConfigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-on-hook(1),
tx-off-hook(2),
rx-relay-open(3),
rx-relay-close(4),
tx-ring-back(5),
rx-oos-alm(6),
txRemoteLB(7),
rxVocalLB(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"on-hook, off-hook, relay-open, relay-close"
::= { em6AllPortSigConfigSetEntry 2 }
em6AllPortSigConfigSetSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { em6AllPortSigConfigSetEntry 3 }
em6AllPortSigConfigSetSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { em6AllPortSigConfigSetEntry 4 }
--
-- E&M Per Port Diag InfoTable
--
em6DiagInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6DiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Diag Info Table"
::= { em-card 10 }
em6DiagInfoEntry OBJECT-TYPE
SYNTAX Em6DiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Diag Infoentry"
INDEX { em6DiagInfoIndex ,
em6DiagInfoPortIndex }
::= { em6DiagInfoTable 1 }
Em6DiagInfoEntry ::= SEQUENCE {
em6DiagInfoIndex LargeSlotIndex,
em6DiagInfoPortIndex EightPortID,
em6DiagInfoSide INTEGER,
em6DiagInfoType INTEGER,
em6DiagInfoElead EMOffOn,
em6DiagInfoMlead EMOffOn,
em6DiagInfoAIS EMOffOn,
em6DiagInfoOOS EMOffOn,
em6DiagInfoInputPW INTEGER,
em6DiagInfoEleadPW INTEGER,
em6DiagInfoPWStatus INTEGER,
em6DiagInfoTx DisplayString,
em6DiagInfoRx DisplayString,
em6DiagInfoAuLaw INTEGER,
em6DiagInfoImp INTEGER,
em6DiagInfoLine INTEGER,
em6DiagInfoTrunk INTEGER,
em6DiagInfoVocalLB EMOffOn
}
em6DiagInfoIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6DiagInfoEntry 1 }
em6DiagInfoPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { em6DiagInfoEntry 2 }
em6DiagInfoSide OBJECT-TYPE
SYNTAX INTEGER {
side-a(1),
side-b(2),
error(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { em6DiagInfoEntry 3}
em6DiagInfoType OBJECT-TYPE
SYNTAX INTEGER {
tx-only(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" signaling type"
::= { em6DiagInfoEntry 4}
em6DiagInfoElead OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E lead "
::= { em6DiagInfoEntry 5}
em6DiagInfoMlead OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" M lead "
::= { em6DiagInfoEntry 6}
em6DiagInfoAIS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" AIS "
::= { em6DiagInfoEntry 7}
em6DiagInfoOOS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OOS "
::= { em6DiagInfoEntry 8}
em6DiagInfoInputPW OBJECT-TYPE
SYNTAX INTEGER {
plusMinus48v(1),
plusMinus24v(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Input power module"
::= { em6DiagInfoEntry 9}
em6DiagInfoEleadPW OBJECT-TYPE
SYNTAX INTEGER {
minus48v(1),
plus24v(2),
plus5v(3),
fail(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" e lead power "
::= { em6DiagInfoEntry 10}
em6DiagInfoPWStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Input power status"
::= { em6DiagInfoEntry 11}
em6DiagInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { em6DiagInfoEntry 12 }
em6DiagInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { em6DiagInfoEntry 13}
em6DiagInfoAuLaw OBJECT-TYPE
SYNTAX INTEGER {
uLaw(1),
aLaw(2),
error(3),
noSupport(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" a u Law "
::= { em6DiagInfoEntry 14}
em6DiagInfoImp OBJECT-TYPE
SYNTAX INTEGER {
imp900ohm(1),
imp600ohm(2),
error(3),
noSupport(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Impdance "
::= { em6DiagInfoEntry 15}
em6DiagInfoLine OBJECT-TYPE
SYNTAX INTEGER {
with2Wire(1),
with4Wire(2),
error(3),
noSupport(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Line "
::= { em6DiagInfoEntry 16}
em6DiagInfoTrunk OBJECT-TYPE
SYNTAX INTEGER {
offHook(1),
onHook(2),
na(3),
noSupport(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Trunk condition "
::= { em6DiagInfoEntry 17}
em6DiagInfoVocalLB OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Vocal LB "
::= { em6DiagInfoEntry 18}
--
-- EM6 Line Diagnostic Control Table
--
em6DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M6 Diagnostic Control Table."
::= { em-card 11 }
em6DiagControlEntry OBJECT-TYPE
SYNTAX Em6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of E&M diagnostic control table."
INDEX { em6DiagControlSlot }
::= { em6DiagControlTable 1 }
Em6DiagControlEntry ::= SEQUENCE {
em6DiagControlSlot LargeSlotIndex,
em6DiagControlTest INTEGER,
em6DiagControlRemain INTEGER
}
em6DiagControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6DiagControlEntry 1 }
em6DiagControlTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
e-lead(2),
voice-loopback(3),
channel-swap(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { em6DiagControlEntry 2 }
em6DiagControlRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { em6DiagControlEntry 3 }
--
-- EM6 All Port Control Table for Phase 4
--
em6AllPortP4CfgSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6AllPortP4CfgSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M6 All Port Configuration Control Table"
::= { em-card 12 }
em6AllPortP4CfgSetEntry OBJECT-TYPE
SYNTAX Em6AllPortP4CfgSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&m6 All Port configuration control entry"
INDEX { em6AllPortP4CfgSetIndex }
::= { em6AllPortP4CfgSetTable 1 }
Em6AllPortP4CfgSetEntry ::= SEQUENCE {
em6AllPortP4CfgSetIndex LargeSlotIndex,
em6AllPortP4CfgSetSide14 INTEGER,
em6AllPortP4CfgSetSide58 INTEGER,
em6AllPortP4CfgSetLine14 INTEGER,
em6AllPortP4CfgSetLine58 INTEGER,
em6AllPortP4CfgSetImp14 INTEGER,
em6AllPortP4CfgSetImp58 INTEGER,
em6AllPortP4CfgSetType14 INTEGER,
em6AllPortP4CfgSetType58 INTEGER,
em6AllPortP4CfgSetAuLaw INTEGER,
-- em6AllPortP4CfgSetAuLaw58 INTEGER,
em6AllPortP4CfgSetTrunk14 INTEGER,
em6AllPortP4CfgSetTrunk58 INTEGER,
em6AllPortP4CfgSetRingBackSW INTEGER,
em6AllPortP4CfgSetTestButton INTEGER,
em6AllPortP4CfgSetRemoteLBbit INTEGER,
em6AllPortP4CfgSetVocalLB INTEGER
}
em6AllPortP4CfgSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6AllPortP4CfgSetEntry 1 }
em6AllPortP4CfgSetSide14 OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M6 Side "
::= { em6AllPortP4CfgSetEntry 2 }
em6AllPortP4CfgSetSide58 OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&M6 Side "
::= { em6AllPortP4CfgSetEntry 3 }
em6AllPortP4CfgSetLine14 OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line L1~ L4"
::= { em6AllPortP4CfgSetEntry 4 }
em6AllPortP4CfgSetLine58 OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Line L5~L8"
::= { em6AllPortP4CfgSetEntry 5 }
em6AllPortP4CfgSetImp14 OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE L1~L4"
::= { em6AllPortP4CfgSetEntry 6 }
em6AllPortP4CfgSetImp58 OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE L5~L8"
::= { em6AllPortP4CfgSetEntry 7 }
em6AllPortP4CfgSetType14 OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Type L1~L4 "
::= { em6AllPortP4CfgSetEntry 8 }
em6AllPortP4CfgSetType58 OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Type L5~L8 "
::= { em6AllPortP4CfgSetEntry 9 }
em6AllPortP4CfgSetAuLaw OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { em6AllPortP4CfgSetEntry 10 }
-- em6AllPortP4CfgSetAuLaw58 OBJECT-TYPE
-- SYNTAX INTEGER {
-- u-law(1),
-- a-law(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " A/u LAW L5~L8"
-- ::= { em6AllPortP4CfgSetEntry 11 }
em6AllPortP4CfgSetTrunk14 OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode L1~L4 "
::= { em6AllPortP4CfgSetEntry 12 }
em6AllPortP4CfgSetTrunk58 OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode L5~L8"
::= { em6AllPortP4CfgSetEntry 13 }
em6AllPortP4CfgSetRingBackSW OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortP4CfgSetEntry 14 }
em6AllPortP4CfgSetTestButton OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { em6AllPortP4CfgSetEntry 15 }
em6AllPortP4CfgSetRemoteLBbit OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Remote Loopback "
::= { em6AllPortP4CfgSetEntry 16 }
em6AllPortP4CfgSetVocalLB OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Loopback Signaling Switch"
::= { em6AllPortP4CfgSetEntry 17 }
--
-- EM6 Line Diagnostic Control Table for Phase4
--
em6P4DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Em6P4DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M6 Diagnostic Control Table."
::= { em-card 13 }
em6P4DiagControlEntry OBJECT-TYPE
SYNTAX Em6P4DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of E&M diagnostic control table."
INDEX { em6P4DiagControlSlot }
::= { em6P4DiagControlTable 1 }
Em6P4DiagControlEntry ::= SEQUENCE {
em6P4DiagControlSlot LargeSlotIndex,
em6P4DiagControlTest INTEGER,
em6P4DiagControlRemain INTEGER,
em6P4DiagControlPeriod INTEGER
}
em6P4DiagControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { em6P4DiagControlEntry 1 }
em6P4DiagControlTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
e-lead(2),
voice-loopback(3),
channel-swap(4),
remote-loopback(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { em6P4DiagControlEntry 2 }
em6P4DiagControlRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { em6P4DiagControlEntry 3 }
em6P4DiagControlPeriod OBJECT-TYPE
SYNTAX INTEGER {
sec10(1),
sec60(2),
sec240(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { em6P4DiagControlEntry 4 }
--
-- EMA Per Port Enable/Disable Control Table
--
emaPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmaPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EMA Per Port Enable Table"
::= { em-card 14 }
emaPortEnableEntry OBJECT-TYPE
SYNTAX EmaPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EMA Per Port Enable entry"
INDEX { emaPortEnableIndex ,
emaPortEnablePort }
::= { emaPortEnableTable 1 }
EmaPortEnableEntry ::= SEQUENCE {
emaPortEnableIndex LargeSlotIndex,
emaPortEnablePort EightPortID,
emaPortEnable INTEGER
}
emaPortEnableIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emaPortEnableEntry 1 }
emaPortEnablePort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { emaPortEnableEntry 2 }
emaPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" port enable/disable"
::= { emaPortEnableEntry 3 }
-- EM Per Port Signaling Config Control Table
emPortSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EM Per Port Signaling Configuration Control Table"
::= { em-card 15 }
emPortSigSetEntry OBJECT-TYPE
SYNTAX EmPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EM Per port signaling configuration control entry"
INDEX { emPortSigSetIndex ,
emPortSigSetPort ,
emPortSigSetItemIndex }
::= { emPortSigSetTable 1 }
EmPortSigSetEntry ::= SEQUENCE {
emPortSigSetIndex LargeSlotIndex,
emPortSigSetPort EightPortID,
emPortSigSetItemIndex INTEGER,
emPortSigSetSigBit DisplayString
}
emPortSigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emPortSigSetEntry 1 }
emPortSigSetPort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-8"
::= { emPortSigSetEntry 2 }
emPortSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-on-hook(1),
tx-off-hook(2),
rx-relay-open(3),
rx-relay-close(4),
tx-ring-back(5),
rx-oos-alm(6),
txRemoteLB(7),
rxVocalLB(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ringing, no-ring, batt-rev, pulse-on, tip-open, off-hook, oos-on, ring-gnd "
::= { emPortSigSetEntry 3 }
emPortSigSetSigBit OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { emPortSigSetEntry 4 }
--
-- EM SetupMode Control Table
--
emSetupModeSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Setup Mode control table."
::= { em-card 16 }
emSetupModeSetEntry OBJECT-TYPE
SYNTAX EmSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Setup Mode control table."
INDEX { emSetupModeSetIndex }
::= { emSetupModeSetTable 1 }
EmSetupModeSetEntry ::= SEQUENCE {
emSetupModeSetIndex LargeSlotIndex,
emSetupModeSetSigMode INTEGER
}
emSetupModeSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emSetupModeSetEntry 1 }
emSetupModeSetSigMode OBJECT-TYPE
SYNTAX INTEGER {
perCard(1),
perPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SigMode Mode"
::= { emSetupModeSetEntry 2 }
--
-- EMA Line Diagnostic Control Table
--
emBertControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMA Bert Control Table."
::= { em-card 17 }
emBertControlEntry OBJECT-TYPE
SYNTAX EmBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of EMA Bert control table."
INDEX { emBertControlSlot }
::= { emBertControlTable 1 }
EmBertControlEntry ::= SEQUENCE {
emBertControlSlot LargeSlotIndex,
emBertControlMode INTEGER,
emBertControlPort INTEGER,
emBertControlType INTEGER,
-- emBertControlSpilt INTEGER,
emBertControlPattern DisplayString,
emBertControlPeriod INTEGER,
emBertControlStatus INTEGER,
emBertControlSync INTEGER,
emBertControlError INTEGER,
emBertControlTime INTEGER,
emBertControlES INTEGER,
emBertControlSES INTEGER,
emBertControlUS INTEGER
}
emBertControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emBertControlEntry 1 }
emBertControlMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
bert(2),
loopback(3),
reset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Mode Select"
::= { emBertControlEntry 2 }
emBertControlPort OBJECT-TYPE
SYNTAX INTEGER{
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
p9(9),
p10(10),
p11(11),
p12(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Port"
::= { emBertControlEntry 3 }
emBertControlType OBJECT-TYPE
SYNTAX INTEGER {
--off(1),
prbs2exp20of1(2),
prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5),
userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { emBertControlEntry 4 }
-- emBertControlSpilt OBJECT-TYPE
-- SYNTAX INTEGER {
-- sendAIS(1),
-- no(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert Spilt Mode"
-- ::= { emBertControlEntry 5 }
emBertControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert User Pattern"
::= { emBertControlEntry 6 }
emBertControlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { emBertControlEntry 7 }
emBertControlStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bert(2),
loopback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { emBertControlEntry 8 }
emBertControlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { emBertControlEntry 9 }
emBertControlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { emBertControlEntry 10 }
emBertControlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { emBertControlEntry 11 }
emBertControlES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Error Second"
::= { emBertControlEntry 12 }
emBertControlSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert SES"
::= { emBertControlEntry 13 }
emBertControlUS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Unsync time"
::= { emBertControlEntry 14 }
--
-- EMA Self Test Control Table
--
emSelfTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EM SelfTest Control Table."
::= { em-card 18 }
emSelfTestControlEntry OBJECT-TYPE
SYNTAX EmSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of EM SelfTest control table."
INDEX { emSelfTestSlot }
::= { emSelfTestControlTable 1 }
EmSelfTestControlEntry ::= SEQUENCE {
emSelfTestSlot LargeSlotIndex,
emSelfTestP1 INTEGER,
emSelfTestP2 INTEGER,
emSelfTestP3 INTEGER,
emSelfTestP4 INTEGER,
emSelfTestP5 INTEGER,
emSelfTestP6 INTEGER,
emSelfTestP7 INTEGER,
emSelfTestP8 INTEGER,
emSelfTestConfirm INTEGER,
emSelfTestStatus INTEGER,
emSelfTestResult DisplayString,
emSelfTestTestType1 INTEGER,
emSelfTestTestRes1 DisplayString,
emSelfTestTestType2 INTEGER,
emSelfTestTestRes2 DisplayString,
emSelfTestTestType3 INTEGER,
emSelfTestTestRes3 DisplayString
}
emSelfTestSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { emSelfTestControlEntry 1 }
emSelfTestP1 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Select"
::= { emSelfTestControlEntry 2 }
emSelfTestP2 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Select"
::= { emSelfTestControlEntry 3 }
emSelfTestP3 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Select"
::= { emSelfTestControlEntry 4 }
emSelfTestP4 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Select"
::= { emSelfTestControlEntry 5 }
emSelfTestP5 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Port Select"
::= { emSelfTestControlEntry 6 }
emSelfTestP6 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Port Select"
::= { emSelfTestControlEntry 7 }
emSelfTestP7 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Port Select"
::= { emSelfTestControlEntry 8 }
emSelfTestP8 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Port Select"
::= { emSelfTestControlEntry 9 }
emSelfTestConfirm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Port Select"
::= { emSelfTestControlEntry 10 }
emSelfTestStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
testing(2),
finish(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Port Select"
::= { emSelfTestControlEntry 11 }
emSelfTestResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Result"
::= { emSelfTestControlEntry 12 }
emSelfTestTestType1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Port Select"
::= { emSelfTestControlEntry 13 }
emSelfTestTestRes1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Result"
::= { emSelfTestControlEntry 14 }
emSelfTestTestType2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Port Select"
::= { emSelfTestControlEntry 15 }
emSelfTestTestRes2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Result"
::= { emSelfTestControlEntry 16 }
emSelfTestTestType3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Port Select"
::= { emSelfTestControlEntry 17 }
emSelfTestTestRes3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Result"
::= { emSelfTestControlEntry 18 }
--
-- EMB Config Control Table
--
embConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&MB Port Configuration Control Table"
::= { em-card 19 }
embConfigControlEntry OBJECT-TYPE
SYNTAX EmbConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&mB Port configuration control entry"
INDEX { embConfigControlSlot ,embConfigControlPort}
::= { embConfigControlTable 1 }
EmbConfigControlEntry ::= SEQUENCE {
embConfigControlSlot LargeSlotIndex,
embConfigControlPort EightPortID,
embConfigControlSide INTEGER,
embConfigControlTxGain DisplayString,
embConfigControlRxGain DisplayString,
embConfigControlLine INTEGER,
embConfigControlImp INTEGER,
embConfigControlAuLaw INTEGER,
embConfigControlSigType INTEGER,
embConfigControlTrunk INTEGER
}
embConfigControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embConfigControlEntry 1 }
embConfigControlPort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&MB Port "
::= { embConfigControlEntry 2 }
embConfigControlSide OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
error(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&MB Side "
::= { embConfigControlEntry 3 }
embConfigControlTxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { embConfigControlEntry 4 }
embConfigControlRxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { embConfigControlEntry 5 }
embConfigControlLine OBJECT-TYPE
SYNTAX INTEGER {
with-2-WIRE(1),
with-4-WIRE(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Line "
::= { embConfigControlEntry 6 }
embConfigControlImp OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2),
followP5(97),
followP1(98)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { embConfigControlEntry 7 }
embConfigControlAuLaw OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2),
followP5(97),
followP1(98)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { embConfigControlEntry 8 }
embConfigControlSigType OBJECT-TYPE
SYNTAX INTEGER {
tx-ONLY(1),
type-1(2),
type-2(3),
type-3(4),
type-4(5),
type-5(6),
error(7),
followP5(97),
followP1(98)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling Type "
::= { embConfigControlEntry 9 }
embConfigControlTrunk OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
on-hook(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&M Trunk Condition Control Mode "
::= { embConfigControlEntry 10 }
--
-- EMB Signaling Control Table
--
embSignalingControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbSignalingControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&MB Port Signaling Control Table"
::= { em-card 20 }
embSignalingControlEntry OBJECT-TYPE
SYNTAX EmbSignalingControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&mB Port Signaling control entry"
INDEX { embSigControlSlot ,embSigControlPort}
::= { embSignalingControlTable 1 }
EmbSignalingControlEntry ::= SEQUENCE {
embSigControlSlot LargeSlotIndex,
embSigControlPort EightPortID,
embSigCtrlRingBackEnable INTEGER,
embSigControlOnHook DisplayString,
embSigControlOffHook DisplayString,
embSigControlRingBack DisplayString,
embSigControlRelayOpen DisplayString,
embSigControlRelayClose DisplayString,
embSigControlOosAlarm DisplayString
}
embSigControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embSignalingControlEntry 1 }
embSigControlPort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E&MB Port "
::= { embSignalingControlEntry 2 }
embSigCtrlRingBackEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling Ring Back enable"
::= { embSignalingControlEntry 3 }
embSigControlOnHook OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling ON HOOK "
::= { embSignalingControlEntry 6 }
embSigControlOffHook OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling OFF HOOK "
::= { embSignalingControlEntry 7 }
embSigControlRingBack OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling RingBack "
::= { embSignalingControlEntry 8 }
embSigControlRelayOpen OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling Relay Open "
::= { embSignalingControlEntry 10 }
embSigControlRelayClose OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling Relay Close "
::= { embSignalingControlEntry 11 }
embSigControlOosAlarm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" E&MB Signaling OOS Alarm"
::= { embSignalingControlEntry 12 }
--
-- E&MB Diag InfoTable
--
embDiagInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&MB Diag Info Table"
::= { em-card 21 }
embDiagInfoEntry OBJECT-TYPE
SYNTAX EmbDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&MB Diag Infoentry"
INDEX { embDiagInfoSlot ,
embDiagInfoPort }
::= { embDiagInfoTable 1 }
EmbDiagInfoEntry ::= SEQUENCE {
embDiagInfoSlot LargeSlotIndex,
embDiagInfoPort EightPortID,
embDiagInfoElead EMOffOn,
embDiagInfoMlead EMOffOn,
-- embDiagInfoVocalLB EMOffOn,
embDiagInfoAisAlm EMOffOn,
embDiagInfoOosAlm EMOffOn,
embDiagInfoTsiAlm EMOffOn,
embDiagInfoTx DisplayString,
embDiagInfoRx DisplayString,
embDiagInfoInputPW INTEGER,
embDiagInfoEleadPW INTEGER,
embDiagInfoPWStatus INTEGER
}
embDiagInfoSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embDiagInfoEntry 1 }
embDiagInfoPort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-8"
::= { embDiagInfoEntry 2 }
embDiagInfoElead OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E lead "
::= { embDiagInfoEntry 3}
embDiagInfoMlead OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" M lead "
::= { embDiagInfoEntry 4}
-- embDiagInfoVocalLB OBJECT-TYPE
-- SYNTAX EMOffOn
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " Vocal LB "
-- ::= { embDiagInfoEntry 5}
embDiagInfoAisAlm OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" AIS "
::= { embDiagInfoEntry 6}
embDiagInfoOosAlm OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OOS "
::= { embDiagInfoEntry 7}
embDiagInfoTsiAlm OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OOS "
::= { embDiagInfoEntry 8}
embDiagInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { embDiagInfoEntry 9 }
embDiagInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { embDiagInfoEntry 10}
embDiagInfoInputPW OBJECT-TYPE
SYNTAX INTEGER {
plusMinus48v(1),
plusMinus24v(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Input power module"
::= { embDiagInfoEntry 11}
embDiagInfoEleadPW OBJECT-TYPE
SYNTAX INTEGER {
minus48v(1),
plus24v(2),
plus5v(3),
fail(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" e lead power "
::= { embDiagInfoEntry 12}
embDiagInfoPWStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Input power status"
::= { embDiagInfoEntry 13}
--
-- EMB Diagnostic Control Table
--
embDiagCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&MB Diagnostic Control Table."
::= { em-card 22 }
embDiagCtrlEntry OBJECT-TYPE
SYNTAX EmbDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of E&M diagnostic control table."
INDEX { embDiagCtrlSlot }
::= { embDiagCtrlTable 1 }
EmbDiagCtrlEntry ::= SEQUENCE {
embDiagCtrlSlot LargeSlotIndex,
embDiagCtrlTestType INTEGER,
embDiagCtrlPort INTEGER,
embDiagCtrlPeriod INTEGER,
embDiagCtrlTxSig DisplayString,
embDiagCtrlStatus INTEGER,
embDiagCtrlRemain INTEGER
}
embDiagCtrlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embDiagCtrlEntry 1 }
embDiagCtrlTestType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
e-lead(2),
voice-loopback(3),
channel-swap(4),
signalingTx(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { embDiagCtrlEntry 2 }
embDiagCtrlPort OBJECT-TYPE
SYNTAX INTEGER {
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
all(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select Port"
::= { embDiagCtrlEntry 3 }
embDiagCtrlPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set test time"
::= { embDiagCtrlEntry 4 }
embDiagCtrlTxSig OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Tx Bit"
::= { embDiagCtrlEntry 5 }
embDiagCtrlStatus OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
e-lead(2),
voice-loopback(3),
channel-swap(4),
signalingTx(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { embDiagCtrlEntry 11 }
embDiagCtrlRemain OBJECT-TYPE
SYNTAX INTEGER {
none(4294967295)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { embDiagCtrlEntry 12 }
--
-- EMB Bert Control Table
--
embBertControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EMA Bert Control Table."
::= { em-card 23 }
embBertControlEntry OBJECT-TYPE
SYNTAX EmbBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of EMA Bert control table."
INDEX { embBertControlSlot }
::= { embBertControlTable 1 }
EmbBertControlEntry ::= SEQUENCE {
embBertControlSlot LargeSlotIndex,
embBertControlMode INTEGER,
embBertControlPort INTEGER,
embBertControlType INTEGER,
-- embBertControlSpilt INTEGER,
embBertControlPattern DisplayString,
embBertControlPeriod INTEGER,
embBertControlStatus INTEGER,
embBertControlSync INTEGER,
embBertControlError INTEGER,
embBertControlTime INTEGER,
embBertControlES INTEGER,
embBertControlSES INTEGER,
embBertControlUS INTEGER
}
embBertControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embBertControlEntry 1 }
embBertControlMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
bert(2),
loopback(3),
reset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Mode Select"
::= { embBertControlEntry 2 }
embBertControlPort OBJECT-TYPE
SYNTAX INTEGER{
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
p9(9),
p10(10),
p11(11),
p12(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Port"
::= { embBertControlEntry 3 }
embBertControlType OBJECT-TYPE
SYNTAX INTEGER {
--off(1),
prbs2exp20of1(2),
prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5),
userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { embBertControlEntry 4 }
-- embBertControlSpilt OBJECT-TYPE
-- SYNTAX INTEGER {
-- sendAIS(1),
-- no(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert Spilt Mode"
-- ::= { embBertControlEntry 5 }
embBertControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert User Pattern"
::= { embBertControlEntry 6 }
embBertControlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { embBertControlEntry 7 }
embBertControlStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bert(2),
loopback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { embBertControlEntry 8 }
embBertControlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { embBertControlEntry 9 }
embBertControlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { embBertControlEntry 10 }
embBertControlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { embBertControlEntry 11 }
embBertControlES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Second"
::= { embBertControlEntry 12 }
embBertControlSES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert SES"
::= { embBertControlEntry 13 }
embBertControlUS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Unsync time"
::= { embBertControlEntry 14 }
--
-- EMB Self Test Control Table
--
embSelfTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"EM SelfTest Control Table."
::= { em-card 24 }
embSelfTestControlEntry OBJECT-TYPE
SYNTAX EmbSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of EM SelfTest control table."
INDEX { embSelfTestSlot }
::= { embSelfTestControlTable 1 }
EmbSelfTestControlEntry ::= SEQUENCE {
embSelfTestSlot LargeSlotIndex,
embSelfTestP1 INTEGER,
embSelfTestP2 INTEGER,
embSelfTestP3 INTEGER,
embSelfTestP4 INTEGER,
embSelfTestP5 INTEGER,
embSelfTestP6 INTEGER,
embSelfTestP7 INTEGER,
embSelfTestP8 INTEGER,
embSelfTestConfirm INTEGER,
embSelfTestStatus INTEGER,
embSelfTestResult DisplayString,
embSelfTestTestType1 INTEGER,
embSelfTestTestRes1 DisplayString,
embSelfTestTestType2 INTEGER,
embSelfTestTestRes2 DisplayString,
embSelfTestTestType3 INTEGER,
embSelfTestTestRes3 DisplayString
}
embSelfTestSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embSelfTestControlEntry 1 }
embSelfTestP1 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { embSelfTestControlEntry 2 }
embSelfTestP2 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { embSelfTestControlEntry 3 }
embSelfTestP3 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { embSelfTestControlEntry 4 }
embSelfTestP4 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { embSelfTestControlEntry 5 }
embSelfTestP5 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { embSelfTestControlEntry 6 }
embSelfTestP6 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { embSelfTestControlEntry 7 }
embSelfTestP7 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { embSelfTestControlEntry 8 }
embSelfTestP8 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { embSelfTestControlEntry 9 }
embSelfTestConfirm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { embSelfTestControlEntry 10 }
embSelfTestStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
testing(2),
finish(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { embSelfTestControlEntry 11 }
embSelfTestResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { embSelfTestControlEntry 12 }
embSelfTestTestType1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { embSelfTestControlEntry 13 }
embSelfTestTestRes1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { embSelfTestControlEntry 14 }
embSelfTestTestType2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { embSelfTestControlEntry 15 }
embSelfTestTestRes2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { embSelfTestControlEntry 16 }
embSelfTestTestType3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
relayTest(2),
nw1034(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { embSelfTestControlEntry 17 }
embSelfTestTestRes3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { embSelfTestControlEntry 18 }
--
-- EMB Per Port Enable/Disable Control Table
--
embPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EMB Per Port Enable Table"
::= { em-card 25 }
embPortEnableEntry OBJECT-TYPE
SYNTAX EmbPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"EMB Per Port Enable entry"
INDEX { embPortEnableIndex ,
embPortEnablePort }
::= { embPortEnableTable 1 }
EmbPortEnableEntry ::= SEQUENCE {
embPortEnableIndex LargeSlotIndex,
embPortEnablePort EightPortID,
embPortEnable INTEGER
}
embPortEnableIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embPortEnableEntry 1 }
embPortEnablePort OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { embPortEnableEntry 2 }
embPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" port enable/disable"
::= { embPortEnableEntry 3 }
--
-- EMB Command Control Table
--
embCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EmbCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { em-card 26 }
embCommandControlEntry OBJECT-TYPE
SYNTAX EmbCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { embCommandControlIndex }
::= { embCommandControlTable 1 }
EmbCommandControlEntry ::= SEQUENCE {
embCommandControlIndex LargeSlotIndex,
embCommandControlReset INTEGER,
embCommandControlLoadDefault INTEGER
}
embCommandControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { embCommandControlEntry 1 }
embCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default E&M CONF"
::= { embCommandControlEntry 2 }
embCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: E&M Card Reset"
::= { embCommandControlEntry 3 }
emTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 8EM"
::= { em-card 100 }
--======================================================================--
--======================================================================--
-- fxs-card MIB
--======================================================================--
-- FXS Card
-- fxsAllPortConfigControlTable OBJECT IDENTIFIER ::= { fxs-card 1 }
-- fxsAllPortSigConfigControlTable OBJECT IDENTIFIER ::= { fxs-card 2 }
-- fxsPerPortConfigControlTable OBJECT IDENTIFIER ::= { fxs-card 3 }
-- fxsPortStatusTable OBJECT IDENTIFIER ::= { fxs-card 4 }
-- fxsDiagTestControlTable OBJECT IDENTIFIER ::= { fxs-card 5 }
-- fxsCommandControlTable OBJECT IDENTIFIER ::= { fxs-card 6 }
-- fxsPerPortEnableTable OBJECT IDENTIFIER ::= { fxs-card 7 }
--======================================================================--
--
-- FXS All Port Config Control Table
--
fxsAllPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS All Port Configuration Control Table"
::= { fxs-card 1 }
fxsAllPortConfigControlEntry OBJECT-TYPE
SYNTAX FxsAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS all port configuration control entry"
INDEX { fxsAllPortConfigControlIndex }
::= { fxsAllPortConfigControlTable 1 }
FxsAllPortConfigControlEntry ::= SEQUENCE {
fxsAllPortConfigControlIndex LargeSlotIndex,
fxsAllPortConfigControlA-u-law INTEGER,
fxsAllPortConfigControlImpedance INTEGER,
-- fxsAllPortConfigControlTx-gain
-- DisplayString,
-- fxsAllPortConfigControlRx-gain
-- DisplayString,
fxsAllPortConfigControlRing-cadence INTEGER,
fxsAllPortConfigControlRing-Freq INTEGER,
fxsAllPortConfigControlMetering-pulse INTEGER,
fxsAllPortConfigControlMetering-freq INTEGER,
fxsAllPortConfigControlMetering-level INTEGER
}
fxsAllPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsAllPortConfigControlEntry 1 }
fxsAllPortConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { fxsAllPortConfigControlEntry 2 }
fxsAllPortConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { fxsAllPortConfigControlEntry 3 }
-- fxsAllPortConfigControlTx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " TX-GAIN "
-- ::= { fxsAllPortConfigControlEntry 4 }
-- fxsAllPortConfigControlRx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " RX-GAIN "
-- ::= { fxsAllPortConfigControlEntry 5 }
fxsAllPortConfigControlRing-cadence OBJECT-TYPE
SYNTAX INTEGER {
cadence-1-on-2-off(1),
cadence-2-on-4-off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ring Cadence "
::= { fxsAllPortConfigControlEntry 6 }
fxsAllPortConfigControlRing-Freq OBJECT-TYPE
SYNTAX INTEGER {
freq-20-hz(1),
freq-25-hz(2),
freq-16-7-hz(3),
freq-50-hz(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ring Frequency "
::= { fxsAllPortConfigControlEntry 7 }
fxsAllPortConfigControlMetering-pulse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Pulse "
::= { fxsAllPortConfigControlEntry 8 }
fxsAllPortConfigControlMetering-freq OBJECT-TYPE
SYNTAX INTEGER {
freq-16k-hz(1),
freq-12k-hz(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Frequency "
::= { fxsAllPortConfigControlEntry 9 }
fxsAllPortConfigControlMetering-level OBJECT-TYPE
SYNTAX INTEGER {
level-2-4-vrms(1),
level-1-vrms(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Level "
::= { fxsAllPortConfigControlEntry 10 }
--
-- FXS All Port Signaling Config Control Table
--
fxsAllPortSigConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS All Port Signaling Configuration Control Table"
::= { fxs-card 2 }
fxsAllPortSigConfigControlEntry OBJECT-TYPE
SYNTAX FxsAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS all port signaling configuration control entry"
INDEX { fxsAllPortSigConfigControlIndex ,
fxsAllPortSigConfigControlItemIndex ,
fxsAllPortSigConfigControlSigBitIndex }
::= { fxsAllPortSigConfigControlTable 1 }
FxsAllPortSigConfigControlEntry ::= SEQUENCE {
fxsAllPortSigConfigControlIndex LargeSlotIndex,
fxsAllPortSigConfigControlItemIndex INTEGER,
fxsAllPortSigConfigControlSigBitIndex INTEGER,
fxsAllPortSigConfigControlSigBit INTEGER
}
fxsAllPortSigConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsAllPortSigConfigControlEntry 1 }
fxsAllPortSigConfigControlItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-on-hook(1),
tx-off-hook(2),
tx-ring-gnd(3),
plar-tx-off-hook(4),
rx-ring-on(5),
rx-batt-rev-and-pulse-on(6),
rx-oos-alarm(7),
rx-tip-open(8),
rx-plar-rx-ring-on(9),
tx-plar-on-hook(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"on-hook, off-hook, ring-gnd, ring-on, batt-rev-pulse-on, oos-on, tip-open"
::= { fxsAllPortSigConfigControlEntry 2 }
fxsAllPortSigConfigControlSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { fxsAllPortSigConfigControlEntry 3 }
fxsAllPortSigConfigControlSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { fxsAllPortSigConfigControlEntry 4 }
--
-- FXS Per Port Config Control Table
--
fxsPerPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per Port Configuration Control Table"
::= { fxs-card 3 }
fxsPerPortConfigControlEntry OBJECT-TYPE
SYNTAX FxsPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per Port Configuration control entry"
INDEX { fxsPerPortConfigControlIndex ,
fxsPerPortConfigControlPortIndex }
::= { fxsPerPortConfigControlTable 1 }
FxsPerPortConfigControlEntry ::= SEQUENCE {
fxsPerPortConfigControlIndex LargeSlotIndex,
fxsPerPortConfigControlPortIndex TwelvePortID,
fxsPerPortConfigControlPLAR INTEGER,
fxsPerPortConfigControlTx-gain DisplayString,
fxsPerPortConfigControlRx-gain DisplayString
}
fxsPerPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsPerPortConfigControlEntry 1 }
fxsPerPortConfigControlPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxsPerPortConfigControlEntry 2 }
fxsPerPortConfigControlPLAR OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
a60(3),
a30(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port PLAR setting "
::= { fxsPerPortConfigControlEntry 3 }
fxsPerPortConfigControlTx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { fxsPerPortConfigControlEntry 4 }
fxsPerPortConfigControlRx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { fxsPerPortConfigControlEntry 5 }
--
-- FXS Port Status Table
--
fxsPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Port Status Table"
::= { fxs-card 4 }
fxsPortStatusEntry OBJECT-TYPE
SYNTAX FxsPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Port Status entry"
INDEX { fxsPortStatusIndex ,
fxsPortStatusItemIndex ,
fxsPortStatusPortIndex }
::= { fxsPortStatusTable 1 }
FxsPortStatusEntry ::= SEQUENCE {
fxsPortStatusIndex LargeSlotIndex,
fxsPortStatusItemIndex INTEGER,
fxsPortStatusPortIndex TwelvePortID,
fxsPortStatusStatus INTEGER
}
fxsPortStatusIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsPortStatusEntry 1 }
fxsPortStatusItemIndex OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
metering-pulse(2),
tip-open(3),
ring-gnd(4),
plar-on(5),
ringing(6),
alarm-on(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"off-hook, ring-on, metering-pulse, tip-open, ring-gnd, plar-on, alarm-on"
::= { fxsPortStatusEntry 2 }
fxsPortStatusPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" port index 1-12 "
::= { fxsPortStatusEntry 3 }
fxsPortStatusStatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Status "
::= { fxsPortStatusEntry 4 }
--
-- FXS Line Diagnostic Control Table
--
fxsDiagTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Diagnostic Control Table."
::= { fxs-card 5 }
fxsDiagTestControlEntry OBJECT-TYPE
SYNTAX FxsDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of FXS diagnostic control table."
INDEX { fxsDiagTestControlIndex }
::= { fxsDiagTestControlTable 1 }
FxsDiagTestControlEntry ::= SEQUENCE {
fxsDiagTestControlIndex LargeSlotIndex,
fxsDiagTestControlType INTEGER,
fxsDiagTestControlRemainTime INTEGER,
fxsDiagTestControlTone INTEGER,
fxsDiagTestControlToneResult DisplayString
}
fxsDiagTestControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsDiagTestControlEntry 1 }
fxsDiagTestControlType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
ring-test(2),
-- metering-pulse-test(3),
battery-reverse(4),
-- fxs dtmf
tone-test(5),
loopback(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Test Button"
::= { fxsDiagTestControlEntry 2 }
fxsDiagTestControlRemainTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remain time (sec)"
::= { fxsDiagTestControlEntry 3 }
fxsDiagTestControlTone OBJECT-TYPE
SYNTAX INTEGER {
n1(2),
n2(3),
n3(4),
n4(5),
n5(6),
n6(7),
n7(8),
n8(9),
n9(10),
n0(11),
asterisk(12),
pound(13),
a(14),
b(15),
c(16),
d(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Test Tone"
::= { fxsDiagTestControlEntry 4 }
fxsDiagTestControlToneResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS Test Tone Result"
::= { fxsDiagTestControlEntry 5 }
--
-- FXS Command Control Table
--
fxsCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { fxs-card 6 }
fxsCommandControlEntry OBJECT-TYPE
SYNTAX FxsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { fxsCommandControlIndex }
::= { fxsCommandControlTable 1 }
FxsCommandControlEntry ::= SEQUENCE {
fxsCommandControlIndex LargeSlotIndex,
fxsCommandControlReset INTEGER,
fxsCommandControlLoadDefault INTEGER
}
fxsCommandControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsCommandControlEntry 1 }
fxsCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default FXS CONF"
::= { fxsCommandControlEntry 2 }
fxsCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: FXS Card Reset"
::= { fxsCommandControlEntry 3 }
--
-- FXS Per Port Enable/Disable Control Table
--
fxsPerPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsPerPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per Port Enable Table"
::= { fxs-card 7 }
fxsPerPortEnableEntry OBJECT-TYPE
SYNTAX FxsPerPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per Port Enable entry"
INDEX { fxsPerPortEnableIndex ,
fxsPerPortEnablePortIndex }
::= { fxsPerPortEnableTable 1 }
FxsPerPortEnableEntry ::= SEQUENCE {
fxsPerPortEnableIndex LargeSlotIndex,
fxsPerPortEnablePortIndex TwelvePortID,
fxsPerPortEnable INTEGER
}
fxsPerPortEnableIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsPerPortEnableEntry 1 }
fxsPerPortEnablePortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxsPerPortEnableEntry 2 }
fxsPerPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS port enable/disable"
::= { fxsPerPortEnableEntry 3 }
--
-- FXS SetupMode Control Table
--
fxsSetupModeSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Setup Mode control table."
::= { fxs-card 8 }
fxsSetupModeSetEntry OBJECT-TYPE
SYNTAX FxsSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Setup Mode control table."
INDEX { fxsSetupModeSetIndex }
::= { fxsSetupModeSetTable 1 }
FxsSetupModeSetEntry ::= SEQUENCE {
fxsSetupModeSetIndex LargeSlotIndex,
fxsSetupModeSetSigMode INTEGER
}
fxsSetupModeSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsSetupModeSetEntry 1 }
fxsSetupModeSetSigMode OBJECT-TYPE
SYNTAX INTEGER {
perCard(1),
perPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SigMode Mode"
::= { fxsSetupModeSetEntry 2 }
-- FXS Per Port Signaling Config Control Table
fxsPortSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per Port Signaling Configuration Control Table"
::= { fxs-card 9}
fxsPortSigSetEntry OBJECT-TYPE
SYNTAX FxsPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXS Per port signaling configuration control entry"
INDEX { fxsPortSigSetIndex ,
fxsPortSigSetPort ,
fxsPortSigSetItemIndex }
::= { fxsPortSigSetTable 1 }
FxsPortSigSetEntry ::= SEQUENCE {
fxsPortSigSetIndex LargeSlotIndex,
fxsPortSigSetPort TwelvePortID,
fxsPortSigSetItemIndex INTEGER,
fxsPortSigSetSigBit DisplayString
}
fxsPortSigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsPortSigSetEntry 1 }
fxsPortSigSetPort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxsPortSigSetEntry 2 }
fxsPortSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
txOnHook(1),
txOffHook(2),
txRingGnd(3),
plarTxOnHook(4),
plarTxOffHook(5),
rxRingOn(6),
rxBattRevAndPulseOn(7),
rxOosAlarm(8),
rxTipOpen(9),
rxPlarRxRingOn(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FXS signaling setup "
::= { fxsPortSigSetEntry 3 }
fxsPortSigSetSigBit OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { fxsPortSigSetEntry 4 }
--
-- FXS Line Diagnostic Control Table
--
fxsBertControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FXS Bert Control Table."
::= { fxs-card 10 }
fxsBertControlEntry OBJECT-TYPE
SYNTAX FxsBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of FXS Bert control table."
INDEX { fxsBertControlSlot }
::= { fxsBertControlTable 1 }
FxsBertControlEntry ::= SEQUENCE {
fxsBertControlSlot LargeSlotIndex,
fxsBertControlMode INTEGER,
fxsBertControlPort INTEGER,
fxsBertControlType INTEGER,
-- fxsBertControlSpilt INTEGER,
fxsBertControlPattern DisplayString,
fxsBertControlPeriod INTEGER,
fxsBertControlStatus INTEGER,
fxsBertControlSync INTEGER,
fxsBertControlError INTEGER,
fxsBertControlTime INTEGER,
fxsBertControlES INTEGER,
fxsBertControlSES INTEGER,
fxsBertControlUS INTEGER
}
fxsBertControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsBertControlEntry 1 }
fxsBertControlMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
bert(2),
loopback(3),
reset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Mode Select"
::= { fxsBertControlEntry 2 }
fxsBertControlPort OBJECT-TYPE
SYNTAX INTEGER{
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
p9(9),
p10(10),
p11(11),
p12(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Port"
::= { fxsBertControlEntry 3 }
fxsBertControlType OBJECT-TYPE
SYNTAX INTEGER {
--off(1),
prbs2exp20of1(2),
prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5),
userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { fxsBertControlEntry 4 }
-- fxsBertControlSpilt OBJECT-TYPE
-- SYNTAX INTEGER {
-- sendAIS(1),
-- no(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert Spilt Mode"
-- ::= { fxsBertControlEntry 5 }
fxsBertControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert User Pattern"
::= { fxsBertControlEntry 6 }
fxsBertControlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { fxsBertControlEntry 7 }
fxsBertControlStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bert(2),
loopback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { fxsBertControlEntry 8 }
fxsBertControlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= {fxsBertControlEntry 9 }
fxsBertControlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { fxsBertControlEntry 10 }
fxsBertControlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { fxsBertControlEntry 11 }
fxsBertControlES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Error Second"
::= { fxsBertControlEntry 12 }
fxsBertControlSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert SES"
::= { fxsBertControlEntry 13 }
fxsBertControlUS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Unsync Second"
::= { fxsBertControlEntry 14 }
--
-- FXS Self Test Control Table
--
fxsSelfTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxsSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FXS SelfTest Control Table."
::= { fxs-card 11 }
fxsSelfTestControlEntry OBJECT-TYPE
SYNTAX FxsSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of FXS SelfTest control table."
INDEX { fxsSelfTestSlot }
::= { fxsSelfTestControlTable 1 }
FxsSelfTestControlEntry ::= SEQUENCE {
fxsSelfTestSlot LargeSlotIndex,
fxsSelfTestP1 INTEGER,
fxsSelfTestP2 INTEGER,
fxsSelfTestP3 INTEGER,
fxsSelfTestP4 INTEGER,
fxsSelfTestP5 INTEGER,
fxsSelfTestP6 INTEGER,
fxsSelfTestP7 INTEGER,
fxsSelfTestP8 INTEGER,
fxsSelfTestP9 INTEGER,
fxsSelfTestP10 INTEGER,
fxsSelfTestP11 INTEGER,
fxsSelfTestP12 INTEGER,
fxsSelfTestConfirm INTEGER,
fxsSelfTestStatus INTEGER,
fxsSelfTestResult DisplayString,
fxsSelfTestTestType1 INTEGER,
fxsSelfTestTestRes1 DisplayString,
fxsSelfTestTestType2 INTEGER,
fxsSelfTestTestRes2 DisplayString,
fxsSelfTestTestType3 INTEGER,
fxsSelfTestTestRes3 DisplayString
}
fxsSelfTestSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxsSelfTestControlEntry 1 }
fxsSelfTestP1 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 2 }
fxsSelfTestP2 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 3 }
fxsSelfTestP3 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 4 }
fxsSelfTestP4 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 5 }
fxsSelfTestP5 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 6 }
fxsSelfTestP6 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 7 }
fxsSelfTestP7 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 8 }
fxsSelfTestP8 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 9 }
fxsSelfTestP9 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 10 }
fxsSelfTestP10 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxsSelfTestControlEntry 11 }
fxsSelfTestP11 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 12 }
fxsSelfTestP12 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 13 }
fxsSelfTestConfirm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxsSelfTestControlEntry 14 }
fxsSelfTestStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
testing(2),
finish(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxsSelfTestControlEntry 15 }
fxsSelfTestResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxsSelfTestControlEntry 16 }
fxsSelfTestTestType1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
dcfeedTest(2),
ringingTest(3),
audioTest(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxsSelfTestControlEntry 17 }
fxsSelfTestTestRes1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxsSelfTestControlEntry 18 }
fxsSelfTestTestType2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
dcfeedTest(2),
ringingTest(3),
audioTest(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxsSelfTestControlEntry 19 }
fxsSelfTestTestRes2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxsSelfTestControlEntry 20 }
fxsSelfTestTestType3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
dcfeedTest(2),
ringingTest(3),
audioTest(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxsSelfTestControlEntry 21 }
fxsSelfTestTestRes3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxsSelfTestControlEntry 22 }
fxsTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 12FXS"
::= { fxs-card 100 }
--======================================================================--
--======================================================================--
-- rtr-card MIB
--======================================================================--
--======================================================================--
--
-- RTR Control Table
-- the IP address table
-- The IP address table contains this entity's IP addressing information.
rtrNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RTR NI Configuration Control Table"
::= { rtr-card 1 }
rtrNiControlEntry OBJECT-TYPE
SYNTAX RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RTR NI configuration control entry"
INDEX { rtrPortNiIndex ,
rtrNetindex }
::= { rtrNiControlTable 1 }
RtrNiControlEntry ::= SEQUENCE {
rtrPortNiIndex SmallSlotIndex,
rtrNetindex INTEGER ,
rtrIPAddr IpAddress,
rtrSubnetMask IpAddress,
rtrFrame INTEGER,
rtrRIP1 INTEGER,
rtrRIP2 INTEGER,
rtrMode INTEGER
}
rtrPortNiIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrNiControlEntry 1 }
rtrNetindex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
lan2(2),
wan1(3),
wan2(4),
wan3(5),
wan4(6),
wan5(7),
wan6(8),
wan7(9),
wan8(10),
wan9(11),
wan10(12),
wan11(13),
wan12(14),
wan13(15),
wan14(16),
wan15(17),
wan16(18),
wan17(19),
wan18(20),
wan19(21),
wan20(22),
wan21(23),
wan22(24),
wan23(25),
wan24(26),
wan25(27),
wan26(28),
wan27(29),
wan28(30),
wan29(31),
wan30(32),
wan31(33),
wan32(34)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" RTR Ni index"
::= { rtrNiControlEntry 2}
rtrIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR IP Address"
::= { rtrNiControlEntry 3}
rtrSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR net mask"
::= { rtrNiControlEntry 4}
rtrFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
ethernet(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Layer2 frame"
::= { rtrNiControlEntry 5}
rtrRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP1"
::= { rtrNiControlEntry 6}
rtrRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP2"
::= { rtrNiControlEntry 7}
rtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR mode"
::= { rtrNiControlEntry 8}
--
-- Route Table
--
rtrRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RTR Route Control Table."
::= { rtr-card 2 }
rtrRouteControlEntry OBJECT-TYPE
SYNTAX RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RTR Route control entry."
INDEX { rtrPortRouteIndex ,
rtrEntry }
::= { rtrRouteControlTable 1 }
RtrRouteControlEntry ::= SEQUENCE {
rtrPortRouteIndex SmallSlotIndex,
rtrEntry INTEGER (1..16),
rtrNetAddr IpAddress,
rtrNetMask IpAddress,
rtrGatewayAddr IpAddress,
rtrNIAddr IpAddress,
rtrMetric INTEGER
}
rtrPortRouteIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrRouteControlEntry 1 }
rtrEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" RTR routeentry"
::= { rtrRouteControlEntry 2}
rtrNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net Address"
::= { rtrRouteControlEntry 3}
rtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net mask"
::= { rtrRouteControlEntry 4}
rtrGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route gateway Address"
::= { rtrRouteControlEntry 5}
rtrNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route NI Address"
::= { rtrRouteControlEntry 6}
rtrMetric OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Route metric"
::= { rtrRouteControlEntry 7}
--
-- RTR Frac Map Table
--
rtrFracCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFracCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Assignment Table."
::= { rtr-card 3 }
rtrFracCtrlEntry OBJECT-TYPE
SYNTAX RtrFracCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Index."
INDEX { rtrPortFracIndex ,
rtrTSIndex }
::= { rtrFracCtrlTable 1 }
RtrFracCtrlEntry ::= SEQUENCE {
rtrPortFracIndex SmallSlotIndex,
rtrTSIndex INTEGER (1..32),
rtrInterface INTEGER
}
rtrPortFracIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrFracCtrlEntry 1 }
rtrTSIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { rtrFracCtrlEntry 2 }
rtrInterface OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
wan2(3),
wan3(4),
wan4(5),
wan5(6),
wan6(7),
wan7(8),
wan8(9),
wan9(10),
wan10(11),
wan11(12),
wan12(13),
wan13(14),
wan14(15),
wan15(16),
wan16(17),
wan17(18),
wan18(19),
wan19(20),
wan20(21),
wan21(22),
wan22(23),
wan23(24),
wan24(25),
wan25(26),
wan26(27),
wan27(28),
wan28(29),
wan29(30),
wan30(31),
wan31(32),
wan32(33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frac ni if index."
::= { rtrFracCtrlEntry 3 }
--
-- Command Control Table
--
rtrCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { rtr-card 4}
rtrCommandControlEntry OBJECT-TYPE
SYNTAX RtrCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { rtrCommandControlIndex }
::= { rtrCommandControlTable 1 }
RtrCommandControlEntry ::= SEQUENCE {
rtrCommandControlIndex SmallSlotIndex,
rtrPortReset INTEGER,
rtrPortLoadDefault INTEGER
}
rtrCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrCommandControlEntry 1 }
rtrPortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset RTR Port"
::= { rtrCommandControlEntry 2 }
rtrPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default RTR Port"
::= { rtrCommandControlEntry 3 }
--
-- SYSTEM Information Table
--
rtrSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { rtr-card 5}
rtrSystemInformationEntry OBJECT-TYPE
SYNTAX RtrSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { rtrSystemInfoIndex }
::= { rtrSystemInformationTable 1 }
RtrSystemInformationEntry ::= SEQUENCE {
rtrSystemInfoIndex SmallSlotIndex,
rtrPROMVersion DisplayString
}
rtrSystemInfoIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrSystemInformationEntry 1 }
rtrPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" RTR EPROM Version"
::= { rtrSystemInformationEntry 2 }
--
-- Ethernet CRC Setup Table
--
rtrCRCSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrCRCSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ethernet CRC Setup table."
::= { rtr-card 6}
rtrCRCSetupEntry OBJECT-TYPE
SYNTAX RtrCRCSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet CRC Setup table."
INDEX { rtrPortIndex }
::= { rtrCRCSetupTable 1 }
RtrCRCSetupEntry ::= SEQUENCE {
rtrPortIndex SmallSlotIndex,
rtrCRCSetup INTEGER
}
rtrPortIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrCRCSetupEntry 1 }
rtrCRCSetup OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR CRC Status and Setup"
::= { rtrCRCSetupEntry 2}
--
-- RTR Alarm Setup Table
--
rtrAlarmSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrAlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Setup Table "
::= { rtr-card 7 }
rtrAlarmSetupEntry OBJECT-TYPE
SYNTAX RtrAlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { rtrAlmSlotIndex }
::= { rtrAlarmSetupTable 1 }
RtrAlarmSetupEntry ::= SEQUENCE {
rtrAlmSlotIndex SmallSlotIndex,
rtrLan1LinkAlarm AlarmSeverity,
rtrLan2LinkAlarm AlarmSeverity
}
rtrAlmSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { rtrAlarmSetupEntry 1 }
rtrLan1LinkAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan 1 Alarm"
::= { rtrAlarmSetupEntry 2 }
rtrLan2LinkAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan 2 Alarm"
::= { rtrAlarmSetupEntry 3 }
rtrTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of RTR"
::= { rtr-card 100 }
--======================================================================--
--======================================================================--
-- atm-card MIB
--======================================================================--
-- ATM/FR
--
-- afr-system OBJECT IDENTIFIER ::= { afr-card 1 }
-- afr-sys-command OBJECT IDENTIFIER ::= { afr-system 1 }
-- afrCommandControlTable OBJECT-TYPE ::= { afr-sys-command 1 }
-- afrSystemInformationTable OBJECT-TYPE ::= { afr-sys-command 2 }
--
-- afr-e1-alm-control OBJECT IDENTIFIER ::= { afr-system 2 }
-- afrE1AlarmControlTable OBJECT-TYPE ::= { afr-e1-alm-control 1 }
-- afrE1ThresholdControlTable OBJECT-TYPE ::= { afr-e1-alm-control 2 }
-- afrE1AlarmQueueTable OBJECT-TYPE ::= { afr-e1-alm-control 3 }
-- afrE1AlarmHistoryTable OBJECT-TYPE ::= { afr-e1-alm-control 4 }
--
-- afr-t1-alm-control OBJECT IDENTIFIER ::= { afr-system 3 }
-- afrT1AlarmControlTable OBJECT-TYPE ::= { afr-t1-alm-control 1 }
-- afrT1ThresholdControlTable OBJECT-TYPE ::= { afr-t1-alm-control 2 }
-- afrT1AlarmQueueTable OBJECT-TYPE ::= { afr-t1-alm-control 3 }
-- afrT1AlarmHistoryTable OBJECT-TYPE ::= { afr-t1-alm-control 4 }
--
-- afr-if OBJECT IDENTIFIER ::= { afr-card 2 }
-- afrFrChMapTable OBJECT-TYPE ::= { afr-if 1 }
-- afrFrMgmtTable OBJECT-TYPE ::= { afr-if 2 }
-- afrVcTable OBJECT-TYPE ::= { afr-if 3 }
-- afrFrStatTable OBJECT-TYPE ::= { afr-if 4 }
-- afrAtmStatTable OBJECT-TYPE ::= { afr-if 5 }
-- afrFrStatusTable OBJECT-TYPE ::= { afr-if 6 }
-- afrAtmStatusTable OBJECT-TYPE ::= { afr-if 7 }
-- afrCsuChannelMapTable OBJECT-TYPE ::= { afr-if 8 }
-- afrDLCITable OBJECT-TYPE ::= { afr-if 9 }
--
-- afr-e1-if OBJECT IDENTIFIER ::= { afr-card 3 }
-- afrE1LineControlTable OBJECT-TYPE ::= { afr-e1-if 1 }
-- afrE1UserCurrentPerfTable OBJECT-TYPE ::= { afr-e1-if 2 }
-- afrE1UserIntervalPerfTable OBJECT-TYPE ::= { afr-e1-if 3 }
-- afrE1UserTotalPerfTable OBJECT-TYPE ::= { afr-e1-if 4 }
-- afrE1UserSevenDaysPerfTable OBJECT-TYPE ::= { afr-e1-if 5 }
-- afrE1LineCurrentPerfTable OBJECT-TYPE ::= { afr-e1-if 10 }
-- afrE1LineIntervalPerfTable OBJECT-TYPE ::= { afr-e1-if 11 }
-- afrE1LineTotalPerfTable OBJECT-TYPE ::= { afr-e1-if 12 }
-- afrE1LineSevenDaysPerfTable OBJECT-TYPE ::= { afr-e1-if 13 }
-- afrE1LineAvailabilityTable OBJECT-TYPE ::= { afr-e1-if 14 }
-- afrE1LineDiagControlTable OBJECT-TYPE ::= { afr-e1-if 15 }
--
-- afr-t1-if OBJECT IDENTIFIER ::= { afr-card 4 }
-- afrT1LineControlTable OBJECT-TYPE ::= { afr-t1-if 1 }
-- afrT1UserCurrentPerfTable OBJECT-TYPE ::= { afr-t1-if 2 }
-- afrT1UserIntervalPerfTable OBJECT-TYPE ::= { afr-t1-if 3 }
-- afrT1UserTotalPerfTable OBJECT-TYPE ::= { afr-t1-if 4 }
-- afrT1LineCurrentPerfTable OBJECT-TYPE ::= { afr-t1-if 8 }
-- afrT1LineIntervalPerfTable OBJECT-TYPE ::= { afr-t1-if 9 }
-- afrT1LineTotalPerfTable OBJECT-TYPE ::= { afr-t1-if 10 }
-- afrT1LineAvailabilityTable OBJECT-TYPE ::= { afr-t1-if 11 }
-- afrT1LineDiagControlTable OBJECT-TYPE ::= { afr-t1-if 12 }
--======================================================================--
--
-- ATM Command Control Table
--
afr-system OBJECT IDENTIFIER ::= { afr-card 1 }
afr-sys-command OBJECT IDENTIFIER ::= { afr-system 1 }
afr-e1-alm-control OBJECT IDENTIFIER ::= { afr-system 2 }
afr-t1-alm-control OBJECT IDENTIFIER ::= { afr-system 3 }
afr-if OBJECT IDENTIFIER ::= { afr-card 2 }
afr-e1-if OBJECT IDENTIFIER ::= { afr-card 3 }
afr-t1-if OBJECT IDENTIFIER ::= { afr-card 4 }
afrCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { afr-sys-command 1 }
afrCommandControlEntry OBJECT-TYPE
SYNTAX AfrCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { afrCommandControlIndex }
::= { afrCommandControlTable 1 }
AfrCommandControlEntry ::= SEQUENCE {
afrCommandControlIndex SmallSlotIndex,
afrAlarmQueueReset INTEGER,
afrUserPerfReset INTEGER,
afrAlarmHistoryReset INTEGER,
afrAtmStatReset INTEGER,
afrFrStatReset INTEGER,
afrPortReset INTEGER,
afrPortLoadDefault INTEGER
}
afrCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrCommandControlEntry 1 }
afrAlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { afrCommandControlEntry 2 }
afrUserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { afrCommandControlEntry 3 }
afrAlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { afrCommandControlEntry 4 }
afrAtmStatReset OBJECT-TYPE
SYNTAX INTEGER (0..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset ATM Statistic History
yyy for pvc, 0 for all"
::= { afrCommandControlEntry 5 }
afrFrStatReset OBJECT-TYPE
SYNTAX INTEGER (0..31128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset FRAMERELAY Statistic History
xxyyy, xx for channel, yyy for pvc, 0 for all"
::= { afrCommandControlEntry 6 }
afrPortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Port"
::= { afrCommandControlEntry 7 }
afrPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-Default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default "
::= { afrCommandControlEntry 8 }
--
-- ATM SYSTEM Information Table
--
afrSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { afr-sys-command 2 }
afrSystemInformationEntry OBJECT-TYPE
SYNTAX AfrSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { afrSystemInfoIndex }
::= { afrSystemInformationTable 1 }
AfrSystemInformationEntry ::= SEQUENCE {
afrSystemInfoIndex SmallSlotIndex,
afrPROMVersion DisplayString
}
afrSystemInfoIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrSystemInformationEntry 1 }
afrPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ATM PROM Version"
::= { afrSystemInformationEntry 2 }
--
-- ATM E1 Alarm Control Table
--
afrE1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-e1-alm-control 1 }
afrE1AlarmControlEntry OBJECT-TYPE
SYNTAX AfrE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the alarm control table."
INDEX { afrE1AlarmControlIndex }
::= { afrE1AlarmControlTable 1 }
AfrE1AlarmControlEntry ::= SEQUENCE {
afrE1AlarmControlIndex SmallSlotIndex,
afrE1RAI-Line AlarmSeverity,
afrE1AIS-Line AlarmSeverity,
afrE1LOS-Line AlarmSeverity,
afrE1LOF-Line AlarmSeverity,
afrE1BPV-Line AlarmSeverity,
afrE1ESS-Line AlarmSeverity,
afrE1UAS-Line AlarmSeverity,
afrE1CSS-Line AlarmSeverity,
afrE1ATM-LOS AlarmSeverity,
afrE1ATM-AIS AlarmSeverity,
afrE1ATM-RDI AlarmSeverity,
afrE1ATM-LOC AlarmSeverity,
afrE1FR-LKD AlarmSeverity
}
afrE1AlarmControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1AlarmControlEntry 1 }
afrE1RAI-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { afrE1AlarmControlEntry 2 }
afrE1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { afrE1AlarmControlEntry 3 }
afrE1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { afrE1AlarmControlEntry 4 }
afrE1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { afrE1AlarmControlEntry 5 }
afrE1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { afrE1AlarmControlEntry 6 }
afrE1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { afrE1AlarmControlEntry 7 }
afrE1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { afrE1AlarmControlEntry 8 }
afrE1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { afrE1AlarmControlEntry 9 }
afrE1ATM-LOS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM Loss Of Sync(delination)
This alarm is only available when ATM protocol is
active"
::= { afrE1AlarmControlEntry 10 }
afrE1ATM-AIS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM AIS State
This alarm is only available when ATM protocol is
active"
::= { afrE1AlarmControlEntry 11 }
afrE1ATM-RDI OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM RDI State
This alarm is only available when ATM protocol is
active"
::= { afrE1AlarmControlEntry 12 }
afrE1ATM-LOC OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM LOC State
This alarm is only available when ATM protocol is
active"
::= { afrE1AlarmControlEntry 13 }
afrE1FR-LKD OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Relay Link Down"
::= { afrE1AlarmControlEntry 14 }
--
-- Threshold Control Table
--
afrE1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-e1-alm-control 2 }
afrE1ThresholdControlEntry OBJECT-TYPE
SYNTAX AfrE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { afrE1ThresholdControlIndex }
::= { afrE1ThresholdControlTable 1 }
AfrE1ThresholdControlEntry ::= SEQUENCE {
afrE1ThresholdControlIndex SmallSlotIndex,
afrE1ThresholdBPV-Line INTEGER,
afrE1ThresholdESS-Line INTEGER,
afrE1ThresholdUAS-Line INTEGER,
afrE1ThresholdCSS-Line INTEGER
}
afrE1ThresholdControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1ThresholdControlEntry 1 }
afrE1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line "
::= { afrE1ThresholdControlEntry 2 }
afrE1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { afrE1ThresholdControlEntry 3 }
afrE1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { afrE1ThresholdControlEntry 4 }
afrE1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { afrE1ThresholdControlEntry 5 }
--
-- Alarm Queue Table
--
afrE1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { afr-e1-alm-control 3 }
afrE1AlarmQueueEntry OBJECT-TYPE
SYNTAX AfrE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { afrE1PortAlarmQIndex ,
afrE1AlarmQueueIndex }
::= { afrE1AlarmQueueTable 1 }
AfrE1AlarmQueueEntry ::= SEQUENCE {
afrE1PortAlarmQIndex SmallSlotIndex,
afrE1AlarmQueueIndex INTEGER (1..40),
afrE1AlarmQueueString DisplayString (SIZE(0..255))
}
afrE1PortAlarmQIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1AlarmQueueEntry 1 }
afrE1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { afrE1AlarmQueueEntry 2 }
afrE1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { afrE1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
afrE1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { afr-e1-alm-control 4 }
afrE1AlarmHistoryEntry OBJECT-TYPE
SYNTAX AfrE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { afrE1PortAlarmHIndex ,
afrE1AlarmHistoryIndex }
::= { afrE1AlarmHistoryTable 1 }
AfrE1AlarmHistoryEntry ::= SEQUENCE {
afrE1PortAlarmHIndex SmallSlotIndex,
afrE1AlarmHistoryIndex INTEGER,
afrE1Threshold INTEGER,
afrE1CurrentState INTEGER,
afrE1CurrentCount INTEGER,
afrE1Alarm AlarmSeverity
}
afrE1PortAlarmHIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1AlarmHistoryEntry 1 }
afrE1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
atm-los(9),
atm-ais(10),
atm-rdi(11),
atm-loc(12),
fr-lkd(13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index
atm-los, atm-ais, atm-rdi, and atm-loc are
only available when the ATM is selected"
::= { afrE1AlarmHistoryEntry 2 }
afrE1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { afrE1AlarmHistoryEntry 3 }
afrE1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { afrE1AlarmHistoryEntry 4 }
afrE1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { afrE1AlarmHistoryEntry 5 }
afrE1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { afrE1AlarmHistoryEntry 6 }
--
-- ATM T1 Alarm Control Table
--
afrT1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-t1-alm-control 1 }
afrT1AlarmControlEntry OBJECT-TYPE
SYNTAX AfrT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the alarm control table."
INDEX { afrT1AlarmControlIndex }
::= { afrT1AlarmControlTable 1 }
AfrT1AlarmControlEntry ::= SEQUENCE {
afrT1AlarmControlIndex SmallSlotIndex,
afrT1YEL-Line AlarmSeverity,
afrT1AIS-Line AlarmSeverity,
afrT1LOS-Line AlarmSeverity,
afrT1LOF-Line AlarmSeverity,
afrT1BPV-Line AlarmSeverity,
afrT1ESS-Line AlarmSeverity,
afrT1UAS-Line AlarmSeverity,
afrT1CSS-Line AlarmSeverity,
afrT1atm-los AlarmSeverity,
afrT1atm-ais AlarmSeverity,
afrT1atm-rdi AlarmSeverity,
afrT1atm-loc AlarmSeverity,
afrT1fr-lkd AlarmSeverity
}
afrT1AlarmControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1AlarmControlEntry 1 }
afrT1YEL-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { afrT1AlarmControlEntry 2 }
afrT1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { afrT1AlarmControlEntry 3 }
afrT1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { afrT1AlarmControlEntry 4 }
afrT1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { afrT1AlarmControlEntry 5 }
afrT1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { afrT1AlarmControlEntry 6 }
afrT1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { afrT1AlarmControlEntry 7 }
afrT1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { afrT1AlarmControlEntry 8 }
afrT1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { afrT1AlarmControlEntry 9 }
afrT1atm-los OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM Loss Of Sync(delination)
This alarm is only available when ATM protocol is
active"
::= { afrT1AlarmControlEntry 10 }
afrT1atm-ais OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM AIS State
This alarm is only available when ATM protocol is
active"
::= { afrT1AlarmControlEntry 11 }
afrT1atm-rdi OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM RDI State
This alarm is only available when ATM protocol is
active"
::= { afrT1AlarmControlEntry 12 }
afrT1atm-loc OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM LOC State
This alarm is only available when ATM protocol is
active"
::= { afrT1AlarmControlEntry 13 }
afrT1fr-lkd OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Relay Link Down"
::= { afrT1AlarmControlEntry 14 }
--
-- ATM T1 Threshold Control Table
--
afrT1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-t1-alm-control 2 }
afrT1ThresholdControlEntry OBJECT-TYPE
SYNTAX AfrT1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { afrT1ThresholdControlIndex }
::= { afrT1ThresholdControlTable 1 }
AfrT1ThresholdControlEntry ::= SEQUENCE {
afrT1ThresholdControlIndex SmallSlotIndex,
afrT1ThresholdBPV-Line INTEGER,
afrT1ThresholdESS-Line INTEGER,
afrT1ThresholdUAS-Line INTEGER,
afrT1ThresholdCSS-Line INTEGER
}
afrT1ThresholdControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1ThresholdControlEntry 1 }
afrT1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line "
::= { afrT1ThresholdControlEntry 2 }
afrT1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { afrT1ThresholdControlEntry 3 }
afrT1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { afrT1ThresholdControlEntry 4 }
afrT1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { afrT1ThresholdControlEntry 5 }
--
-- ATM T1 Alarm Queue Table
--
afrT1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { afr-t1-alm-control 3 }
afrT1AlarmQueueEntry OBJECT-TYPE
SYNTAX AfrT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { afrT1PortAlarmQIndex ,
afrT1AlarmQueueIndex }
::= { afrT1AlarmQueueTable 1 }
AfrT1AlarmQueueEntry ::= SEQUENCE {
afrT1PortAlarmQIndex SmallSlotIndex,
afrT1AlarmQueueIndex INTEGER (1..40),
afrT1AlarmQueueString DisplayString (SIZE(0..255))
}
afrT1PortAlarmQIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1AlarmQueueEntry 1 }
afrT1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { afrT1AlarmQueueEntry 2 }
afrT1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { afrT1AlarmQueueEntry 3 }
--
-- ATM T1 Alarm History Table
--
afrT1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { afr-t1-alm-control 4 }
afrT1AlarmHistoryEntry OBJECT-TYPE
SYNTAX AfrT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { afrT1PortAlarmHIndex ,
afrT1AlarmHistoryIndex }
::= { afrT1AlarmHistoryTable 1 }
AfrT1AlarmHistoryEntry ::= SEQUENCE {
afrT1PortAlarmHIndex SmallSlotIndex,
afrT1AlarmHistoryIndex INTEGER,
afrT1Threshold INTEGER,
afrT1CurrentState INTEGER,
afrT1CurrentCount INTEGER,
afrT1Alarm AlarmSeverity
}
afrT1PortAlarmHIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1AlarmHistoryEntry 1 }
afrT1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
atm-los(9),
atm-ais(10),
atm-rdi(11),
atm-loc(12),
fr-lkd(13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index
atm-los, atm-ais, atm-rdi, and atm-loc are
only available when the ATM is selected"
::= { afrT1AlarmHistoryEntry 2 }
afrT1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { afrT1AlarmHistoryEntry 3 }
afrT1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { afrT1AlarmHistoryEntry 4 }
afrT1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { afrT1AlarmHistoryEntry 5 }
afrT1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { afrT1AlarmHistoryEntry 6 }
--
-- ATM Frme Relay channel Map Table
--
afrFrChMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrFrChMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Assignment Table."
::= { afr-if 1 }
afrFrChMapEntry OBJECT-TYPE
SYNTAX AfrFrChMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Index."
INDEX { afrchmapIndex ,
afrTimeSlotIndex }
::= { afrFrChMapTable 1 }
AfrFrChMapEntry ::= SEQUENCE {
afrchmapIndex SmallSlotIndex,
afrTimeSlotIndex INTEGER,
afrMapToFR INTEGER
}
afrchmapIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrFrChMapEntry 1 }
afrTimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { afrFrChMapEntry 2 }
afrMapToFR OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR index."
::= { afrFrChMapEntry 3 }
--
-- ATM Fr Mgmt Table
--
afrFrMgmtTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrFrMgmtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR management Table."
::= { afr-if 2 }
afrFrMgmtEntry OBJECT-TYPE
SYNTAX AfrFrMgmtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR management Index."
INDEX { afrFrMgmtIndex ,
afrFrIndex }
::= { afrFrMgmtTable 1 }
AfrFrMgmtEntry ::= SEQUENCE {
afrFrMgmtIndex SmallSlotIndex,
afrFrIndex INTEGER,
frActive INTEGER,
frProtocol INTEGER,
frDirection INTEGER,
frT391 INTEGER,
frT392 INTEGER,
frN391 INTEGER,
frN392 INTEGER,
frN393 INTEGER
}
afrFrMgmtIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrFrMgmtEntry 1 }
afrFrIndex OBJECT-TYPE
SYNTAX INTEGER {
ch1(1),
ch2(2),
ch3(3),
ch4(4),
ch5(5),
ch6(6),
ch7(7),
ch8(8),
ch9(9),
ch10(10),
ch11(11),
ch12(12),
ch13(13),
ch14(14),
ch15(15),
ch16(16),
ch17(17),
ch18(18),
ch19(19),
ch20(20),
ch21(21),
ch22(22),
ch23(23),
ch24(24),
ch25(25),
ch26(26),
ch27(27),
ch28(28),
ch29(29),
ch30(30),
ch31(31),
ch-line(33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CH1~CH31: logical FR index.
When Frame Relay is active on T1/E1 port, CH-LINE
identifies the frame relay channel on the T1/E1 port."
::= { afrFrMgmtEntry 2 }
frActive OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When afrFrIndex is 33, this field is read only"
::= { afrFrMgmtEntry 3 }
frProtocol OBJECT-TYPE
SYNTAX INTEGER {
fr-ansi(1),
fr-itu(3),
hdlc(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" FR Protocol"
::= { afrFrMgmtEntry 4 }
frDirection OBJECT-TYPE
SYNTAX INTEGER {
network(1),
user(2),
bidirection(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Direction"
::= { afrFrMgmtEntry 5 }
frT391 OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR T391"
::= { afrFrMgmtEntry 6 }
frT392 OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR T392"
::= { afrFrMgmtEntry 7 }
frN391 OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR N391"
::= { afrFrMgmtEntry 8 }
frN392 OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR N392"
::= { afrFrMgmtEntry 9 }
frN393 OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR N393"
::= { afrFrMgmtEntry 10 }
--
-- ATM VC Table
--
afrVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrVcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FrameRelay-to-ATM virtual connection table
This table is only available when ATM is active"
::= { afr-if 3 }
afrVcEntry OBJECT-TYPE
SYNTAX AfrVcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VC management Index."
INDEX { afrVcTabIndex ,
afrVcVcIndex }
::= { afrVcTable 1 }
AfrVcEntry ::= SEQUENCE {
afrVcTabIndex SmallSlotIndex,
afrVcVcIndex INTEGER,
vcChannel INTEGER,
vcDLCI INTEGER,
vcVPI INTEGER,
vcVCI INTEGER,
vcBR INTEGER,
vcALBR INTEGER,
vcInterworking INTEGER,
vcTranslation INTEGER,
vcDECLP INTEGER
}
afrVcTabIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrVcEntry 1 }
afrVcVcIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VC index."
::= { afrVcEntry 2 }
vcChannel OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR channel index."
::= { afrVcEntry 3 }
vcDLCI OBJECT-TYPE
SYNTAX INTEGER (16..991)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FR DLCI"
::= { afrVcEntry 4 }
vcVPI OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM VPI"
::= { afrVcEntry 5 }
vcVCI OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM VCI"
::= { afrVcEntry 6 }
vcBR OBJECT-TYPE
SYNTAX INTEGER (1..1920)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit Rate"
::= { afrVcEntry 7 }
vcALBR OBJECT-TYPE
SYNTAX INTEGER (1..1920)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"allocated Bit Rate"
::= { afrVcEntry 8 }
vcInterworking OBJECT-TYPE
SYNTAX INTEGER {
network(1),
svc-mode1(2),
svc-mode2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"interworking mode"
::= { afrVcEntry 9 }
vcTranslation OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
null(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"translation mode"
::= { afrVcEntry 10 }
vcDECLP OBJECT-TYPE
SYNTAX INTEGER {
map(1),
zero(2),
one(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DECLP mode"
::= { afrVcEntry 11 }
--
-- ATM Fr STAT Table
--
afrFrStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrFrStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR statistics Table."
::= { afr-if 4 }
afrFrStatEntry OBJECT-TYPE
SYNTAX AfrFrStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR statistics Index."
INDEX { afrFrstatIndex ,
afrFrstatFrIndex ,
afrFrstatPVCIndex }
::= { afrFrStatTable 1 }
AfrFrStatEntry ::= SEQUENCE {
afrFrstatIndex SmallSlotIndex,
afrFrstatFrIndex INTEGER,
afrFrstatPVCIndex INTEGER,
afrFrstatDLCI INTEGER,
afrFrstatRX-Bytes INTEGER,
afrFrstatRX-Frames INTEGER,
afrFrstatRX-Discards INTEGER,
afrFrstatRX-Drops INTEGER,
afrFrstatTX-Bytes INTEGER,
afrFrstatTX-Frames INTEGER,
afrFrstatTX-Discards INTEGER,
afrFrstatTX-Drops INTEGER
}
afrFrstatIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrFrStatEntry 1 }
afrFrstatFrIndex OBJECT-TYPE
SYNTAX INTEGER {
ch1(1),
ch2(2),
ch3(3),
ch4(4),
ch5(5),
ch6(6),
ch7(7),
ch8(8),
ch9(9),
ch10(10),
ch11(11),
ch12(12),
ch13(13),
ch14(14),
ch15(15),
ch16(16),
ch17(17),
ch18(18),
ch19(19),
ch20(20),
ch21(21),
ch22(22),
ch23(23),
ch24(24),
ch25(25),
ch26(26),
ch27(27),
ch28(28),
ch29(29),
ch30(30),
ch31(31),
ch-line(33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CH1~CH31: logical FR index.
When Frame Relay is active on T1/E1 port, CH-LINE
identifies the frame relay channel on the T1/E1 port."
::= { afrFrStatEntry 2 }
afrFrstatPVCIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PVC index."
::= { afrFrStatEntry 3 }
afrFrstatDLCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FR DLCI"
::= { afrFrStatEntry 4 }
afrFrstatRX-Bytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX-Bytes"
::= { afrFrStatEntry 5 }
afrFrstatRX-Frames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX-Frames"
::= { afrFrStatEntry 6 }
afrFrstatRX-Discards OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX-Discards"
::= { afrFrStatEntry 7 }
afrFrstatRX-Drops OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX-Drops"
::= { afrFrStatEntry 8 }
afrFrstatTX-Bytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX-Bytes"
::= { afrFrStatEntry 9 }
afrFrstatTX-Frames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX-Frames"
::= { afrFrStatEntry 10 }
afrFrstatTX-Discards OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX-Discards"
::= { afrFrStatEntry 11 }
afrFrstatTX-Drops OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX-Drops"
::= { afrFrStatEntry 12 }
--
-- ATM VC STAT Table
--
afrAtmStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrAtmStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ATM statistics Table
This table is only available when ATM is active"
::= { afr-if 5 }
afrAtmStatEntry OBJECT-TYPE
SYNTAX AfrAtmStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VC statistics Index."
INDEX { afrAtmStatTabIndex ,
afrAtmStatVcIndex }
::= { afrAtmStatTable 1 }
AfrAtmStatEntry ::= SEQUENCE {
afrAtmStatTabIndex SmallSlotIndex,
afrAtmStatVcIndex INTEGER,
afrAtmStatVPI INTEGER,
afrAtmStatVCI INTEGER,
afrAtmStatRX-Frames INTEGER,
afrAtmStatTX-Frames INTEGER,
afrAtmStatCongestion INTEGER,
-- afrAtmStatBAD-HEC
-- INTEGER,
afrAtmStatBAD-CRC INTEGER,
afrAtmStatBAD-Length INTEGER
}
afrAtmStatTabIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrAtmStatEntry 1 }
afrAtmStatVcIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VC index."
::= { afrAtmStatEntry 2 }
afrAtmStatVPI OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VPI"
::= { afrAtmStatEntry 3 }
afrAtmStatVCI OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VCI"
::= { afrAtmStatEntry 4 }
afrAtmStatRX-Frames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RX-Frames"
::= { afrAtmStatEntry 5 }
afrAtmStatTX-Frames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TX-Frames"
::= { afrAtmStatEntry 6 }
afrAtmStatCongestion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"congestion"
::= { afrAtmStatEntry 7 }
-- afrAtmStatBAD-HEC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "bad header CRC"
-- ::= { afrAtmStatEntry 8 }
afrAtmStatBAD-CRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bad CRC"
::= { afrAtmStatEntry 9 }
afrAtmStatBAD-Length OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bad length "
::= { afrAtmStatEntry 10 }
--
-- ATM Fr STATUS Table
--
afrFrStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrFrStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR status Table."
::= { afr-if 6 }
afrFrStatusEntry OBJECT-TYPE
SYNTAX AfrFrStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FR status Index."
INDEX { afrFrStatusIndex ,
afrFrStatusFrIndex }
::= { afrFrStatusTable 1 }
AfrFrStatusEntry ::= SEQUENCE {
afrFrStatusIndex SmallSlotIndex,
afrFrStatusFrIndex INTEGER,
afrFrStatusStatus INTEGER
}
afrFrStatusIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrFrStatusEntry 1 }
afrFrStatusFrIndex OBJECT-TYPE
SYNTAX INTEGER {
ch1(1),
ch2(2),
ch3(3),
ch4(4),
ch5(5),
ch6(6),
ch7(7),
ch8(8),
ch9(9),
ch10(10),
ch11(11),
ch12(12),
ch13(13),
ch14(14),
ch15(15),
ch16(16),
ch17(17),
ch18(18),
ch19(19),
ch20(20),
ch21(21),
ch22(22),
ch23(23),
ch24(24),
ch25(25),
ch26(26),
ch27(27),
ch28(28),
ch29(29),
ch30(30),
ch31(31),
ch-line(33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CH1~CH31: logical FR index.
When Frame Relay is active on T1/E1 port, CH-LINE
identifies the frame relay channel on the T1/E1 port."
::= { afrFrStatusEntry 2 }
afrFrStatusStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
inactive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FR status"
::= { afrFrStatusEntry 3 }
--
-- ATM VC STATUS Table
--
afrAtmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrAtmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ATM VC status Table.
This table is only available when ATM is active"
::= { afr-if 7 }
afrAtmStatusEntry OBJECT-TYPE
SYNTAX AfrAtmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VC status Index."
INDEX { afrAtmStatusTabIndex ,
afrAtmStatusVcIndex }
::= { afrAtmStatusTable 1 }
AfrAtmStatusEntry ::= SEQUENCE {
afrAtmStatusTabIndex SmallSlotIndex,
afrAtmStatusVcIndex INTEGER,
afrAtmStatusActive INTEGER,
afrAtmStatusAIS INTEGER,
afrAtmStatusRDI INTEGER,
afrAtmStatusLOC INTEGER
}
afrAtmStatusTabIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrAtmStatusEntry 1 }
afrAtmStatusVcIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VC index."
::= { afrAtmStatusEntry 2 }
afrAtmStatusActive OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VC active"
::= { afrAtmStatusEntry 3 }
afrAtmStatusAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { afrAtmStatusEntry 4 }
afrAtmStatusRDI OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RDI"
::= { afrAtmStatusEntry 5 }
afrAtmStatusLOC OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOC"
::= { afrAtmStatusEntry 6 }
--
-- E1 Line Control Table
--
afrE1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { afr-e1-if 1 }
afrE1LineControlEntry OBJECT-TYPE
SYNTAX AfrE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { afrE1csuLineControlIndex }
::= { afrE1LineControlTable 1 }
AfrE1LineControlEntry ::= SEQUENCE {
afrE1csuLineControlIndex SmallSlotIndex,
afrE1csuLineFrame INTEGER,
afrE1csuLineCoding INTEGER,
afrE1csuInterface INTEGER,
afrE1csuFDL INTEGER,
afrE1csuFDLSabit INTEGER,
afrE1csuAIS INTEGER,
afrE1csuRAI INTEGER,
afrE1csuCRC INTEGER,
afrE1csuCAS INTEGER,
afrE1csuProtocol INTEGER
}
afrE1csuLineControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineControlEntry 1 }
afrE1csuLineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { afrE1LineControlEntry 2 }
afrE1csuLineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { afrE1LineControlEntry 3 }
afrE1csuInterface OBJECT-TYPE
SYNTAX INTEGER {
twisted-Pair(1),
coaxial-Cable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that E1 line use 75/120 Ohm Cable."
::= { afrE1LineControlEntry 4 }
afrE1csuFDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link ON/OFF"
::= { afrE1LineControlEntry 5 }
afrE1csuFDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
sa4-5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link use Sax bit"
::= { afrE1LineControlEntry 6 }
afrE1csuAIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 line Alarm Indication Signal."
::= { afrE1LineControlEntry 7 }
afrE1csuRAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
on-A(3),
on-B(4),
on-C(5),
on-D(6),
on-E(7),
on-F(8),
on-H(9),
on-J(10),
on-K(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { afrE1LineControlEntry 8 }
afrE1csuCRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Cycle Redundancy Check ON/OFF"
::= { afrE1LineControlEntry 9 }
afrE1csuCAS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Line CAS ON/OFF"
::= { afrE1LineControlEntry 11 }
afrE1csuProtocol OBJECT-TYPE
SYNTAX INTEGER {
atm(1),
frameRelay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protocol running on E1 port
Notice:
To activate new selected protocol, the plug-in card will
automatically reboot itself when protocol on T1 port is
changed. (All configurations stored in this card will be
returned to default.)"
::= { afrE1LineControlEntry 16 }
--
-- ATM E1 User Current Performance Table
--
afrE1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { afr-e1-if 2 }
afrE1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX AfrE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { afrE1csuUserCurrentPerfIndex }
::= { afrE1UserCurrentPerfTable 1 }
AfrE1UserCurrentPerfEntry ::= SEQUENCE {
afrE1csuUserCurrentPerfIndex SmallSlotIndex,
afrE1csuUserCurrentPerfES INTEGER,
afrE1csuUserCurrentPerfSES INTEGER,
afrE1csuUserCurrentPerfBES INTEGER,
afrE1csuUserCurrentPerfUAS INTEGER,
afrE1csuUserCurrentPerfCSS INTEGER,
afrE1csuUserCurrentPerfBPV INTEGER,
afrE1csuUserCurrentPerfDM INTEGER
}
afrE1csuUserCurrentPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1UserCurrentPerfEntry 1 }
afrE1csuUserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1UserCurrentPerfEntry 2 }
afrE1csuUserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1UserCurrentPerfEntry 3 }
afrE1csuUserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1UserCurrentPerfEntry 4 }
afrE1csuUserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1UserCurrentPerfEntry 5 }
afrE1csuUserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { afrE1UserCurrentPerfEntry 6 }
afrE1csuUserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1UserCurrentPerfEntry 7 }
afrE1csuUserCurrentPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1UserCurrentPerfEntry 8 }
--
-- ATM E1 User Interval Performance Table
--
afrE1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { afr-e1-if 3 }
afrE1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX AfrE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { afrE1csuUserIntervalPerfIndex ,
afrE1csuUserIntervalPerfNumber }
::= { afrE1UserIntervalPerfTable 1 }
AfrE1UserIntervalPerfEntry ::= SEQUENCE {
afrE1csuUserIntervalPerfIndex SmallSlotIndex,
afrE1csuUserIntervalPerfNumber INTEGER (1..96),
afrE1csuUserIntervalPerfES INTEGER,
afrE1csuUserIntervalPerfSES INTEGER,
afrE1csuUserIntervalPerfBES INTEGER,
afrE1csuUserIntervalPerfUAS INTEGER,
afrE1csuUserIntervalPerfCSS INTEGER,
afrE1csuUserIntervalPerfBPV INTEGER,
afrE1csuUserIntervalPerfDM INTEGER
}
afrE1csuUserIntervalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1UserIntervalPerfEntry 1 }
afrE1csuUserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { afrE1UserIntervalPerfEntry 2 }
afrE1csuUserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1UserIntervalPerfEntry 3 }
afrE1csuUserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1UserIntervalPerfEntry 4 }
afrE1csuUserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1UserIntervalPerfEntry 5 }
afrE1csuUserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1UserIntervalPerfEntry 6 }
afrE1csuUserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1UserIntervalPerfEntry 7 }
afrE1csuUserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1UserIntervalPerfEntry 8 }
afrE1csuUserIntervalPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
afrE1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { afr-e1-if 4 }
afrE1UserTotalPerfEntry OBJECT-TYPE
SYNTAX AfrE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { afrE1csuUserTotalPerfIndex }
::= { afrE1UserTotalPerfTable 1 }
AfrE1UserTotalPerfEntry ::= SEQUENCE {
afrE1csuUserTotalPerfIndex SmallSlotIndex,
afrE1csuUserTotalPerfES INTEGER,
afrE1csuUserTotalPerfSES INTEGER,
afrE1csuUserTotalPerfBES INTEGER,
afrE1csuUserTotalPerfUAS INTEGER,
afrE1csuUserTotalPerfCSS INTEGER,
afrE1csuUserTotalPerfBPV INTEGER,
afrE1csuUserTotalPerfDM INTEGER
}
afrE1csuUserTotalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1UserTotalPerfEntry 1 }
afrE1csuUserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1UserTotalPerfEntry 2 }
afrE1csuUserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1UserTotalPerfEntry 3 }
afrE1csuUserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1UserTotalPerfEntry 4 }
afrE1csuUserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1UserTotalPerfEntry 5 }
afrE1csuUserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1UserTotalPerfEntry 6 }
afrE1csuUserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1UserTotalPerfEntry 7 }
afrE1csuUserTotalPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
afrE1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { afr-e1-if 5 }
afrE1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX AfrE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { afrE1csuUser7DaysPerfIndex ,
afrE1csuUserDaysIndex }
::= { afrE1UserSevenDaysPerfTable 1 }
AfrE1UserSevenDaysPerfEntry ::= SEQUENCE {
afrE1csuUser7DaysPerfIndex SmallSlotIndex,
afrE1csuUserDaysIndex INTEGER (1..7),
afrE1csuUserDateStrIndex DisplayString (SIZE (0..255) ),
afrE1csuUserSevenDaysPerfES INTEGER,
afrE1csuUserSevenDaysPerfSES INTEGER,
afrE1csuUserSevenDaysPerfBES INTEGER,
afrE1csuUserSevenDaysPerfUAS INTEGER,
afrE1csuUserSevenDaysPerfCSS INTEGER,
afrE1csuUserSevenDaysPerfDM INTEGER
}
afrE1csuUser7DaysPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1UserSevenDaysPerfEntry 1 }
afrE1csuUserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { afrE1UserSevenDaysPerfEntry 2 }
afrE1csuUserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { afrE1UserSevenDaysPerfEntry 3 }
afrE1csuUserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1UserSevenDaysPerfEntry 4 }
afrE1csuUserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1UserSevenDaysPerfEntry 5 }
afrE1csuUserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1UserSevenDaysPerfEntry 6 }
afrE1csuUserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1UserSevenDaysPerfEntry 7 }
afrE1csuUserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1UserSevenDaysPerfEntry 8 }
afrE1csuUserSevenDaysPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1UserSevenDaysPerfEntry 9 }
--
-- Line Current Performance Table
--
afrE1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { afr-e1-if 10 }
afrE1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX AfrE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { afrE1csuLineCurrentPerfIndex }
::= { afrE1LineCurrentPerfTable 1 }
AfrE1LineCurrentPerfEntry ::= SEQUENCE {
afrE1csuLineCurrentPerfIndex SmallSlotIndex,
afrE1csuLineCurrentPerfES INTEGER,
afrE1csuLineCurrentPerfSES INTEGER,
afrE1csuLineCurrentPerfBES INTEGER,
afrE1csuLineCurrentPerfUAS INTEGER,
afrE1csuLineCurrentPerfCSS INTEGER,
afrE1csuLineCurrentPerfBPV INTEGER,
afrE1csuLineCurrentPerfDM INTEGER
}
afrE1csuLineCurrentPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineCurrentPerfEntry 1 }
afrE1csuLineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { afrE1LineCurrentPerfEntry 2 }
afrE1csuLineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1LineCurrentPerfEntry 3 }
afrE1csuLineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1LineCurrentPerfEntry 4 }
afrE1csuLineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1LineCurrentPerfEntry 5 }
afrE1csuLineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1LineCurrentPerfEntry 6 }
afrE1csuLineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1LineCurrentPerfEntry 7 }
afrE1csuLineCurrentPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1LineCurrentPerfEntry 8 }
--
-- Line Interval Performance Table
--
afrE1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { afr-e1-if 11 }
afrE1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX AfrE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { afrE1csuLineIntervalPerfIndex ,
afrE1csuLineIntervalPerfNumber }
::= { afrE1LineIntervalPerfTable 1 }
AfrE1LineIntervalPerfEntry ::= SEQUENCE {
afrE1csuLineIntervalPerfIndex SmallSlotIndex,
afrE1csuLineIntervalPerfNumber INTEGER (1..96),
afrE1csuLineIntervalPerfES INTEGER,
afrE1csuLineIntervalPerfSES INTEGER,
afrE1csuLineIntervalPerfBES INTEGER,
afrE1csuLineIntervalPerfUAS INTEGER,
afrE1csuLineIntervalPerfCSS INTEGER,
afrE1csuLineIntervalPerfBPV INTEGER,
afrE1csuLineIntervalPerfDM INTEGER
}
afrE1csuLineIntervalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineIntervalPerfEntry 1 }
afrE1csuLineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { afrE1LineIntervalPerfEntry 2 }
afrE1csuLineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1LineIntervalPerfEntry 3 }
afrE1csuLineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1LineIntervalPerfEntry 4 }
afrE1csuLineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1LineIntervalPerfEntry 5 }
afrE1csuLineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1LineIntervalPerfEntry 6 }
afrE1csuLineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1LineIntervalPerfEntry 7 }
afrE1csuLineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1LineIntervalPerfEntry 8 }
afrE1csuLineIntervalPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1LineIntervalPerfEntry 9 }
--
-- Line Total Performance Table
--
afrE1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { afr-e1-if 12 }
afrE1LineTotalPerfEntry OBJECT-TYPE
SYNTAX AfrE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { afrE1csuLineTotalPerfIndex }
::= { afrE1LineTotalPerfTable 1 }
AfrE1LineTotalPerfEntry ::= SEQUENCE {
afrE1csuLineTotalPerfIndex SmallSlotIndex,
afrE1csuLineTotalPerfES INTEGER,
afrE1csuLineTotalPerfSES INTEGER,
afrE1csuLineTotalPerfBES INTEGER,
afrE1csuLineTotalPerfUAS INTEGER,
afrE1csuLineTotalPerfCSS INTEGER,
afrE1csuLineTotalPerfBPV INTEGER,
afrE1csuLineTotalPerfDM INTEGER
}
afrE1csuLineTotalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineTotalPerfEntry 1 }
afrE1csuLineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1LineTotalPerfEntry 2 }
afrE1csuLineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1LineTotalPerfEntry 3 }
afrE1csuLineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1LineTotalPerfEntry 4 }
afrE1csuLineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1LineTotalPerfEntry 5 }
afrE1csuLineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1LineTotalPerfEntry 6 }
afrE1csuLineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrE1LineTotalPerfEntry 7 }
afrE1csuLineTotalPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
afrE1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { afr-e1-if 13 }
afrE1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX AfrE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { afrE1csuLine7DaysPerfIndex ,
afrE1csuLineDaysIndex }
::= { afrE1LineSevenDaysPerfTable 1 }
AfrE1LineSevenDaysPerfEntry ::= SEQUENCE {
afrE1csuLine7DaysPerfIndex SmallSlotIndex,
afrE1csuLineDaysIndex INTEGER (1..7),
afrE1csuLineDateStrIndex DisplayString (SIZE (0..255) ),
afrE1csuLineSevenDaysPerfES INTEGER,
afrE1csuLineSevenDaysPerfSES INTEGER,
afrE1csuLineSevenDaysPerfBES INTEGER,
afrE1csuLineSevenDaysPerfUAS INTEGER,
afrE1csuLineSevenDaysPerfCSS INTEGER,
afrE1csuLineSevenDaysPerfDM INTEGER
}
afrE1csuLine7DaysPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineSevenDaysPerfEntry 1 }
afrE1csuLineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { afrE1LineSevenDaysPerfEntry 2 }
afrE1csuLineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { afrE1LineSevenDaysPerfEntry 3 }
afrE1csuLineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrE1LineSevenDaysPerfEntry 4 }
afrE1csuLineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrE1LineSevenDaysPerfEntry 5 }
afrE1csuLineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrE1LineSevenDaysPerfEntry 6 }
afrE1csuLineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrE1LineSevenDaysPerfEntry 7 }
afrE1csuLineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrE1LineSevenDaysPerfEntry 8 }
afrE1csuLineSevenDaysPerfDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { afrE1LineSevenDaysPerfEntry 9 }
--
-- Line Availability Table
--
afrE1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { afr-e1-if 14 }
afrE1LineAvailabilityEntry OBJECT-TYPE
SYNTAX AfrE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { afrE1csuPortAvailabilityIndex }
::= { afrE1LineAvailabilityTable 1 }
AfrE1LineAvailabilityEntry ::= SEQUENCE {
afrE1csuPortAvailabilityIndex SmallSlotIndex,
afrE1csuAvailableSeconds DisplayString,
afrE1csuUnavailableSeconds DisplayString,
afrE1csuLineAvailability DisplayString
}
afrE1csuPortAvailabilityIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineAvailabilityEntry 1 }
afrE1csuAvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { afrE1LineAvailabilityEntry 2 }
afrE1csuUnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { afrE1LineAvailabilityEntry 3 }
afrE1csuLineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { afrE1LineAvailabilityEntry 4 }
--
-- Line Diagnostic Control Table
--
afrE1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-e1-if 15 }
afrE1LineDiagControlEntry OBJECT-TYPE
SYNTAX AfrE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { afrE1csuLineDiagControlIndex }
::= { afrE1LineDiagControlTable 1 }
AfrE1LineDiagControlEntry ::= SEQUENCE {
afrE1csuLineDiagControlIndex SmallSlotIndex,
afrE1csuLoopbackType INTEGER,
afrE1csuLoopbackStatus INTEGER,
afrE1csuPRBSControl INTEGER,
afrE1csuPRBSStatus INTEGER,
afrE1csuPRBSElapseSeconds INTEGER,
afrE1csuPRBSErrorSeconds INTEGER,
afrE1csuPRBSErrorCounts INTEGER,
afrE1csuInbandLoopbackPeriod INTEGER
}
afrE1csuLineDiagControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrE1LineDiagControlEntry 1 }
afrE1csuLoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payLoadLoopback(3),
lineLoopback(4),
remotePayLoadLB-Active(5),
remoteLineLB-Active(6),
remotePayLoadLb-Deactive(7),
remoteLineLB-Deactive(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"atm-e1csu Loopback Type"
::= { afrE1LineDiagControlEntry 2 }
afrE1csuLoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
lb-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-e1csu Loopback Status"
::= { afrE1LineDiagControlEntry 3 }
afrE1csuPRBSControl OBJECT-TYPE
SYNTAX INTEGER {
prbs-DEACTIVE(1),
prbs-ACTIVE-FULL(2),
prbs-RESET-ERROR-COUNT(3),
prbs-INJECT-ERROR(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"atm-e1csu PRBS Control"
::= { afrE1LineDiagControlEntry 4 }
afrE1csuPRBSStatus OBJECT-TYPE
SYNTAX INTEGER {
prbs-SYNC(1),
prbs-UNSYNC(2),
prbs-NOT-ACTIVE(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-e1csu PRBS Status"
::= { afrE1LineDiagControlEntry 5 }
afrE1csuPRBSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-e1csu PRBS Elapse Seconds"
::= { afrE1LineDiagControlEntry 6 }
afrE1csuPRBSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-e1csu PRBS Error Seconds"
::= { afrE1LineDiagControlEntry 7 }
afrE1csuPRBSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-e1csu PRBS Error Counts"
::= { afrE1LineDiagControlEntry 8 }
afrE1csuInbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of E1 inband local, payload, or line loopback"
::= { afrE1LineDiagControlEntry 9 }
--
-- ATM T1 Line Control Table
--
afrT1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { afr-t1-if 1 }
afrT1LineControlEntry OBJECT-TYPE
SYNTAX AfrT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { afrT1csuLineControlIndex }
::= { afrT1LineControlTable 1 }
AfrT1LineControlEntry ::= SEQUENCE {
afrT1csuLineControlIndex SmallSlotIndex,
afrT1csuLineFrame INTEGER,
afrT1csuLineCoding INTEGER,
afrT1csuInterface INTEGER,
afrT1csuLineBuildOut INTEGER,
afrT1csuEQUalizer INTEGER,
afrT1csuAIS INTEGER,
afrT1csuYEL INTEGER,
afrT1csuInband INTEGER,
afrT1csuProtocol INTEGER
}
afrT1csuLineControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineControlEntry 1 }
afrT1csuLineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esf-T1-403(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { afrT1LineControlEntry 2 }
afrT1csuLineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { afrT1LineControlEntry 3 }
afrT1csuInterface OBJECT-TYPE
SYNTAX INTEGER {
long-Haul(1),
short-Haul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that T1 line use Long/Short haul."
::= { afrT1LineControlEntry 4 }
afrT1csuLineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo-0-0dB(1),
lbo-7-5dB(2),
lbo-15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line build out."
::= { afrT1LineControlEntry 5 }
afrT1csuEQUalizer OBJECT-TYPE
SYNTAX INTEGER {
equ-0-133Ft(1),
equ-133-266Ft(2),
equ-266-399Ft(3),
equ-399-533Ft(4),
equ-533-655Ft(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line equalizer."
::= { afrT1LineControlEntry 6 }
afrT1csuAIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line Alarm Indication Signal."
::= { afrT1LineControlEntry 7 }
afrT1csuYEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
on-A(3),
on-B(4),
on-C(5),
on-D(6),
on-E(7),
on-F(8),
on-H(9),
on-J(10),
on-K(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { afrT1LineControlEntry 8 }
afrT1csuInband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line inband ON/OFF"
::= { afrT1LineControlEntry 9 }
afrT1csuProtocol OBJECT-TYPE
SYNTAX INTEGER {
atm(1),
frameRelay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protocol running on T1 port
Notice:
To activate new selected protocol, the plug-in card will
automatically reboot itself when protocol on T1 port is
changed. (All configurations stored in this card will be
returned to default.)"
::= { afrT1LineControlEntry 16 }
--
-- User Current Performance Table
--
afrT1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { afr-t1-if 2 }
afrT1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX AfrT1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { afrT1csuUserCurrentPerfIndex }
::= { afrT1UserCurrentPerfTable 1 }
AfrT1UserCurrentPerfEntry ::= SEQUENCE {
afrT1csuUserCurrentPerfIndex SmallSlotIndex,
afrT1csuUserCurrentPerfES INTEGER,
afrT1csuUserCurrentPerfSES INTEGER,
afrT1csuUserCurrentPerfBES INTEGER,
afrT1csuUserCurrentPerfUAS INTEGER,
afrT1csuUserCurrentPerfCSS INTEGER,
afrT1csuUserCurrentPerfBPV INTEGER,
afrT1csuUserCurrentPerfLOFC INTEGER
}
afrT1csuUserCurrentPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1UserCurrentPerfEntry 1 }
afrT1csuUserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrT1UserCurrentPerfEntry 2 }
afrT1csuUserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1UserCurrentPerfEntry 3 }
afrT1csuUserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1UserCurrentPerfEntry 4 }
afrT1csuUserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1UserCurrentPerfEntry 5 }
afrT1csuUserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { afrT1UserCurrentPerfEntry 6 }
afrT1csuUserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1UserCurrentPerfEntry 7 }
afrT1csuUserCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1UserCurrentPerfEntry 8 }
--
-- User Interval Performance Table
--
afrT1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { afr-t1-if 3 }
afrT1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX AfrT1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { afrT1csuUserIntervalPerfIndex ,
afrT1csuUserIntervalPerfNumber }
::= { afrT1UserIntervalPerfTable 1 }
AfrT1UserIntervalPerfEntry ::= SEQUENCE {
afrT1csuUserIntervalPerfIndex SmallSlotIndex,
afrT1csuUserIntervalPerfNumber INTEGER (1..96),
afrT1csuUserIntervalPerfES INTEGER,
afrT1csuUserIntervalPerfSES INTEGER,
afrT1csuUserIntervalPerfBES INTEGER,
afrT1csuUserIntervalPerfUAS INTEGER,
afrT1csuUserIntervalPerfCSS INTEGER,
afrT1csuUserIntervalPerfBPV INTEGER,
afrT1csuUserIntervalPerfLOFC INTEGER
}
afrT1csuUserIntervalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1UserIntervalPerfEntry 1 }
afrT1csuUserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { afrT1UserIntervalPerfEntry 2 }
afrT1csuUserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrT1UserIntervalPerfEntry 3 }
afrT1csuUserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1UserIntervalPerfEntry 4 }
afrT1csuUserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1UserIntervalPerfEntry 5 }
afrT1csuUserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1UserIntervalPerfEntry 6 }
afrT1csuUserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrT1UserIntervalPerfEntry 7 }
afrT1csuUserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1UserIntervalPerfEntry 8 }
afrT1csuUserIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
afrT1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { afr-t1-if 4 }
afrT1UserTotalPerfEntry OBJECT-TYPE
SYNTAX AfrT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { afrT1csuUserTotalPerfIndex }
::= { afrT1UserTotalPerfTable 1 }
AfrT1UserTotalPerfEntry ::= SEQUENCE {
afrT1csuUserTotalPerfIndex SmallSlotIndex,
afrT1csuUserTotalPerfES INTEGER,
afrT1csuUserTotalPerfSES INTEGER,
afrT1csuUserTotalPerfBES INTEGER,
afrT1csuUserTotalPerfUAS INTEGER,
afrT1csuUserTotalPerfCSS INTEGER,
afrT1csuUserTotalPerfBPV INTEGER,
afrT1csuUserTotalPerfLOFC INTEGER
}
afrT1csuUserTotalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1UserTotalPerfEntry 1 }
afrT1csuUserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrT1UserTotalPerfEntry 2 }
afrT1csuUserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1UserTotalPerfEntry 3 }
afrT1csuUserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1UserTotalPerfEntry 4 }
afrT1csuUserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1UserTotalPerfEntry 5 }
afrT1csuUserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrT1UserTotalPerfEntry 6 }
afrT1csuUserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1UserTotalPerfEntry 7 }
afrT1csuUserTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1UserTotalPerfEntry 8 }
--
-- Line Current Performance Table
--
afrT1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { afr-t1-if 8 }
afrT1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX AfrT1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { afrT1csuLineCurrentPerfIndex }
::= { afrT1LineCurrentPerfTable 1 }
AfrT1LineCurrentPerfEntry ::= SEQUENCE {
afrT1csuLineCurrentPerfIndex SmallSlotIndex,
afrT1csuLineCurrentPerfES INTEGER,
afrT1csuLineCurrentPerfSES INTEGER,
afrT1csuLineCurrentPerfBES INTEGER,
afrT1csuLineCurrentPerfUAS INTEGER,
afrT1csuLineCurrentPerfCSS INTEGER,
afrT1csuLineCurrentPerfBPV INTEGER,
afrT1csuLineCurrentPerfLOFC INTEGER
}
afrT1csuLineCurrentPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineCurrentPerfEntry 1 }
afrT1csuLineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { afrT1LineCurrentPerfEntry 2 }
afrT1csuLineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1LineCurrentPerfEntry 3 }
afrT1csuLineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1LineCurrentPerfEntry 4 }
afrT1csuLineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1LineCurrentPerfEntry 5 }
afrT1csuLineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrT1LineCurrentPerfEntry 6 }
afrT1csuLineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1LineCurrentPerfEntry 7 }
afrT1csuLineCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1LineCurrentPerfEntry 8 }
--
-- Line Interval Performance Table
--
afrT1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { afr-t1-if 9 }
afrT1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX AfrT1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { afrT1csuLineIntervalPerfIndex ,
afrT1csuLineIntervalPerfNumber }
::= { afrT1LineIntervalPerfTable 1 }
AfrT1LineIntervalPerfEntry ::= SEQUENCE {
afrT1csuLineIntervalPerfIndex SmallSlotIndex,
afrT1csuLineIntervalPerfNumber INTEGER (1..96),
afrT1csuLineIntervalPerfES INTEGER,
afrT1csuLineIntervalPerfSES INTEGER,
afrT1csuLineIntervalPerfBES INTEGER,
afrT1csuLineIntervalPerfUAS INTEGER,
afrT1csuLineIntervalPerfCSS INTEGER,
afrT1csuLineIntervalPerfBPV INTEGER,
afrT1csuLineIntervalPerfLOFC INTEGER
}
afrT1csuLineIntervalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineIntervalPerfEntry 1 }
afrT1csuLineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index "
::= { afrT1LineIntervalPerfEntry 2 }
afrT1csuLineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrT1LineIntervalPerfEntry 3 }
afrT1csuLineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1LineIntervalPerfEntry 4 }
afrT1csuLineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1LineIntervalPerfEntry 5 }
afrT1csuLineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1LineIntervalPerfEntry 6 }
afrT1csuLineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrT1LineIntervalPerfEntry 7 }
afrT1csuLineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1LineIntervalPerfEntry 8 }
afrT1csuLineIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1LineIntervalPerfEntry 9 }
--
-- Line Total Performance Table
--
afrT1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { afr-t1-if 10 }
afrT1LineTotalPerfEntry OBJECT-TYPE
SYNTAX AfrT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance entry"
INDEX { afrT1csuLineTotalPerfIndex }
::= { afrT1LineTotalPerfTable 1 }
AfrT1LineTotalPerfEntry ::= SEQUENCE {
afrT1csuLineTotalPerfIndex SmallSlotIndex,
afrT1csuLineTotalPerfES INTEGER,
afrT1csuLineTotalPerfSES INTEGER,
afrT1csuLineTotalPerfBES INTEGER,
afrT1csuLineTotalPerfUAS INTEGER,
afrT1csuLineTotalPerfCSS INTEGER,
afrT1csuLineTotalPerfBPV INTEGER,
afrT1csuLineTotalPerfLOFC INTEGER
}
afrT1csuLineTotalPerfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineTotalPerfEntry 1 }
afrT1csuLineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { afrT1LineTotalPerfEntry 2 }
afrT1csuLineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { afrT1LineTotalPerfEntry 3 }
afrT1csuLineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { afrT1LineTotalPerfEntry 4 }
afrT1csuLineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { afrT1LineTotalPerfEntry 5 }
afrT1csuLineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { afrT1LineTotalPerfEntry 6 }
afrT1csuLineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { afrT1LineTotalPerfEntry 7 }
afrT1csuLineTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { afrT1LineTotalPerfEntry 8 }
--
-- Line Availability Table
--
afrT1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { afr-t1-if 11 }
afrT1LineAvailabilityEntry OBJECT-TYPE
SYNTAX AfrT1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { afrT1csuPortAvailabilityIndex }
::= { afrT1LineAvailabilityTable 1 }
AfrT1LineAvailabilityEntry ::= SEQUENCE {
afrT1csuPortAvailabilityIndex SmallSlotIndex,
afrT1csuAvailableSeconds DisplayString,
afrT1csuUnavailableSeconds DisplayString,
afrT1csuLineAvailability DisplayString
}
afrT1csuPortAvailabilityIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineAvailabilityEntry 1 }
afrT1csuAvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { afrT1LineAvailabilityEntry 2 }
afrT1csuUnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { afrT1LineAvailabilityEntry 3 }
afrT1csuLineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { afrT1LineAvailabilityEntry 4 }
--
-- ATM T1 line Diagnostic Control Table
--
afrT1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrT1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { afr-t1-if 12 }
afrT1LineDiagControlEntry OBJECT-TYPE
SYNTAX AfrT1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { afrT1csuLineDiagControlIndex }
::= { afrT1LineDiagControlTable 1 }
AfrT1LineDiagControlEntry ::= SEQUENCE {
afrT1csuLineDiagControlIndex SmallSlotIndex,
afrT1csuLoopbackType INTEGER,
afrT1csuLoopbackStatus INTEGER,
afrT1csuQRSSControl INTEGER,
afrT1csuQRSSStatus INTEGER,
afrT1csuQRSSElapseSeconds INTEGER,
afrT1csuQRSSErrorSeconds INTEGER,
afrT1csuQRSSErrorCounts INTEGER,
afrT1csuInbandLoopbackPeriod INTEGER
}
afrT1csuLineDiagControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrT1LineDiagControlEntry 1 }
afrT1csuLoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payLoadLoopback(3),
lineLoopback(4),
remoteLineLB-Inband-Active(5),
remotePayLoadLB-ATT-Active(6),
remotePayLoadLB-ANSI-Active(7),
remoteLineLB-ANSI-Active(8),
remoteLineLB-Inband-Deactive(9),
remotePayLoadLB-ATT-Deactive(10),
remotePayLoadLB-ANSI-Deactive(11),
remoteLineLB-ANSI-Deactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"atm-t1csu Loopback Type"
::= { afrT1LineDiagControlEntry 2 }
afrT1csuLoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
lb-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-t1csu Loopback Status"
::= { afrT1LineDiagControlEntry 3 }
afrT1csuQRSSControl OBJECT-TYPE
SYNTAX INTEGER {
qrss-DEACTIVE(1),
qrss-ACTIVE-FULL(2),
qrss-RESET-ERROR-COUNT(3),
qrss-INJECT-ERROR(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"atm-t1csu QRSS Control"
::= { afrT1LineDiagControlEntry 4 }
afrT1csuQRSSStatus OBJECT-TYPE
SYNTAX INTEGER {
qrss-SYNC(1),
qrss-UNSYNC(2),
qrss-NOT-ACTIVE(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-t1csu QRSS Status"
::= { afrT1LineDiagControlEntry 5 }
afrT1csuQRSSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-t1csu QRSS Elapse Seconds"
::= { afrT1LineDiagControlEntry 6 }
afrT1csuQRSSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-t1csu QRSS Error Seconds"
::= { afrT1LineDiagControlEntry 7 }
afrT1csuQRSSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"atm-t1csu QRSS Error Counts"
::= { afrT1LineDiagControlEntry 8 }
afrT1csuInbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of T1 inband local, payload, or line loopback"
::= { afrT1LineDiagControlEntry 9 }
--
-- ATM CSU DS0 Map Table
--
afrCsuChannelMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrCsuChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Channel map on T1/E1"
::= { afr-if 8 }
afrCsuChannelMapEntry OBJECT-TYPE
SYNTAX AfrCsuChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of channel map table"
INDEX { afrCsuChannelMapTableIndex ,
afrCsuChannelMapEntryIndex }
::= { afrCsuChannelMapTable 1 }
AfrCsuChannelMapEntry ::= SEQUENCE {
afrCsuChannelMapTableIndex SmallSlotIndex,
afrCsuChannelMapEntryIndex INTEGER,
afrCsuChannelMapTo INTEGER
}
afrCsuChannelMapTableIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrCsuChannelMapEntry 1 }
afrCsuChannelMapEntryIndex OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index.
T1: 1~24
E1: 1~31"
::= { afrCsuChannelMapEntry 2 }
afrCsuChannelMapTo OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
map(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"0: this time slot is idle
1: this time slot carries user data"
::= { afrCsuChannelMapEntry 3 }
--
-- FR-to-FR DLCI mapping table
--
afrDLCITable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrDLCIEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FrameRelay-to-FrameRelay DLCI mapping table
This table is only available when FR on T1/E1 is active"
::= { afr-if 9 }
afrDLCIEntry OBJECT-TYPE
SYNTAX AfrDLCIEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VC management Index."
INDEX { afrDlciTableIndex ,
afrDlciEntryIndex }
::= { afrDLCITable 1 }
AfrDLCIEntry ::= SEQUENCE {
afrDlciTableIndex SmallSlotIndex,
afrDlciEntryIndex INTEGER,
logicalChannel INTEGER,
logicalDLCI INTEGER,
dlci INTEGER,
cir INTEGER,
allocatedBandwidth INTEGER,
bc INTEGER,
be INTEGER
}
afrDlciTableIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrDLCIEntry 1 }
afrDlciEntryIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Entry index."
::= { afrDLCIEntry 2 }
logicalChannel OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Which logical frame relay channel"
::= { afrDLCIEntry 3 }
logicalDLCI OBJECT-TYPE
SYNTAX INTEGER (1..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DLCI in this logical frame relay channel"
::= { afrDLCIEntry 4 }
dlci OBJECT-TYPE
SYNTAX INTEGER (1..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DLCI in T1/E1 channel"
::= { afrDLCIEntry 5 }
cir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Information Rate"
::= { afrDLCIEntry 6 }
allocatedBandwidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Really allocated bandwidth for this virtual connection.
In normal case, AllocatedBandwidth is same as CIR"
::= { afrDLCIEntry 7 }
bc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Burst size"
::= { afrDLCIEntry 8 }
be OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Excess Burst size"
::= { afrDLCIEntry 9 }
--
-- ATM LINE STAT Table
--
afrAtmLineStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AfrAtmLineStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ATM Line statistics Table
This table is only available when ATM is active"
::= { afr-if 10 }
afrAtmLineStatEntry OBJECT-TYPE
SYNTAX AfrAtmLineStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VC statistics Index."
INDEX { afrAtmLineStatTabIndex }
::= { afrAtmLineStatTable 1 }
AfrAtmLineStatEntry ::= SEQUENCE {
afrAtmLineStatTabIndex SmallSlotIndex,
afrAtmLINE-STAT INTEGER,
afrAtmBAD-HEC INTEGER
}
afrAtmLineStatTabIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { afrAtmLineStatEntry 1 }
afrAtmBAD-HEC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bad header CRC"
::= { afrAtmLineStatEntry 2 }
afrAtmLINE-STAT OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ATM Line Sync/unsync"
::= { afrAtmLineStatEntry 3 }
afrTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of ATM/FR"
::= { afr-card 100 }
--======================================================================--
--======================================================================--
-- fxo-card MIB
--======================================================================--
-- FXO Card
-- fxoAllPortConfigControlTable OBJECT IDENTIFIER ::= { fxo-card 1 }
-- fxoAllPortSigConfigControlTable OBJECT IDENTIFIER ::= { fxo-card 2 }
-- fxoPerPortConfigControlTable OBJECT IDENTIFIER ::= { fxo-card 3 }
-- fxoPortStatusTable OBJECT IDENTIFIER ::= { fxo-card 4 }
-- fxoDiagTestControlTable OBJECT IDENTIFIER ::= { fxo-card 5 }
-- fxoCommandControlTable OBJECT IDENTIFIER ::= { fxo-card 6 }
--======================================================================--
FXOPulseDecodeLevel ::= INTEGER {
na(0),
-- neg-18-dbm(18),
neg-19-dbm(19),
neg-20-dbm(20),
neg-21-dbm(21),
neg-22-dbm(22),
neg-23-dbm(23),
neg-24-dbm(24),
neg-25-dbm(25),
neg-26-dbm(26),
neg-27-dbm(27),
neg-28-dbm(28),
neg-29-dbm(29),
neg-30-dbm(30),
neg-31-dbm(31),
neg-32-dbm(32),
neg-33-dbm(33),
neg-34-dbm(34),
neg-35-dbm(35),
neg-36-dbm(36),
neg-37-dbm(37),
neg-38-dbm(38),
neg-39-dbm(39),
neg-40-dbm(40),
neg-41-dbm(41),
neg-42-dbm(42),
neg-43-dbm(43),
neg-44-dbm(44),
neg-45-dbm(45),
neg-46-dbm(46),
neg-47-dbm(47)
}
--
-- FXO All Port Config Control Table
--
fxoAllPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO All Port Configuration Control Table"
::= { fxo-card 1 }
fxoAllPortConfigControlEntry OBJECT-TYPE
SYNTAX FxoAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO all port configuration control entry"
INDEX { fxoAllPortConfigControlIndex }
::= { fxoAllPortConfigControlTable 1 }
FxoAllPortConfigControlEntry ::= SEQUENCE {
fxoAllPortConfigControlIndex LargeSlotIndex,
fxoAllPortConfigControlA-u-law INTEGER,
fxoAllPortConfigControlImpedance INTEGER,
-- fxoAllPortConfigControlTx-gain
-- DisplayString,
-- fxoAllPortConfigControlRx-gain
-- DisplayString,
fxoAllPortConfigControlTrunk-condition INTEGER,
fxoAllPortConfigControlLine-polarity INTEGER,
fxoAllPortConfigControlMetering-pulse-frequency INTEGER,
fxoAllPortConfigControlPulse-detect-mode INTEGER
}
fxoAllPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoAllPortConfigControlEntry 1 }
fxoAllPortConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { fxoAllPortConfigControlEntry 2 }
fxoAllPortConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { fxoAllPortConfigControlEntry 3 }
-- fxoAllPortConfigControlTx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " TX-GAIN "
-- ::= { fxoAllPortConfigControlEntry 4 }
-- fxoAllPortConfigControlRx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " RX-GAIN "
-- ::= { fxoAllPortConfigControlEntry 5 }
fxoAllPortConfigControlTrunk-condition OBJECT-TYPE
SYNTAX INTEGER {
on-hook(1),
off-hook(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Trunk Condition "
::= { fxoAllPortConfigControlEntry 6 }
fxoAllPortConfigControlLine-polarity OBJECT-TYPE
SYNTAX INTEGER {
reverse(1),
normal(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Line Polarity "
::= { fxoAllPortConfigControlEntry 7 }
fxoAllPortConfigControlMetering-pulse-frequency OBJECT-TYPE
SYNTAX INTEGER {
freq-16k-hz(1),
freq-12k-hz(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Pulse Frequency "
::= { fxoAllPortConfigControlEntry 8 }
fxoAllPortConfigControlPulse-detect-mode OBJECT-TYPE
SYNTAX INTEGER {
packet(1),
normal(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Pulse Detect Mode "
::= { fxoAllPortConfigControlEntry 9 }
--
-- FXO All Port Signaling Config Control Table
--
fxoAllPortSigConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO All Port Signaling Configuration Control Table"
::= { fxo-card 2 }
fxoAllPortSigConfigControlEntry OBJECT-TYPE
SYNTAX FxoAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO all port signaling configuration control entry"
INDEX { fxoAllPortSigConfigControlIndex ,
fxoAllPortSigConfigControlItemIndex ,
fxoAllPortSigConfigControlSigBitIndex }
::= { fxoAllPortSigConfigControlTable 1 }
FxoAllPortSigConfigControlEntry ::= SEQUENCE {
fxoAllPortSigConfigControlIndex LargeSlotIndex,
fxoAllPortSigConfigControlItemIndex INTEGER,
fxoAllPortSigConfigControlSigBitIndex INTEGER,
fxoAllPortSigConfigControlSigBit INTEGER
}
fxoAllPortSigConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoAllPortSigConfigControlEntry 1 }
fxoAllPortSigConfigControlItemIndex OBJECT-TYPE
SYNTAX INTEGER {
ringing(1),
no-ring(2),
batt-rev(3),
pulse-on(4),
tip-open(5),
off-hook(6),
oos-alarm(7),
ring-gnd(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ringing, no-ring, batt-rev, pulse-on, tip-open, off-hook, oos-on, ring-gnd "
::= { fxoAllPortSigConfigControlEntry 2 }
fxoAllPortSigConfigControlSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { fxoAllPortSigConfigControlEntry 3 }
fxoAllPortSigConfigControlSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { fxoAllPortSigConfigControlEntry 4 }
--
-- FXO Per Port Config Control Table
--
fxoPerPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Configuration Control Table"
::= { fxo-card 3 }
fxoPerPortConfigControlEntry OBJECT-TYPE
SYNTAX FxoPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Configuration control entry"
INDEX { fxoPerPortConfigControlIndex ,
fxoPerPortConfigControlPortIndex }
::= { fxoPerPortConfigControlTable 1 }
FxoPerPortConfigControlEntry ::= SEQUENCE {
fxoPerPortConfigControlIndex LargeSlotIndex,
fxoPerPortConfigControlPortIndex TwelvePortID,
fxoPerPortConfigControlPulse-Decode-Level FXOPulseDecodeLevel,
fxoPerPortConfigControlDetected-Pulse-Decode-Level FXOPulseDecodeLevel,
fxoPerPortConfigControlTx-gain DisplayString,
fxoPerPortConfigControlRx-gain DisplayString
}
fxoPerPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoPerPortConfigControlEntry 1 }
fxoPerPortConfigControlPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxoPerPortConfigControlEntry 2 }
fxoPerPortConfigControlPulse-Decode-Level OBJECT-TYPE
SYNTAX FXOPulseDecodeLevel
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port Pulse Decode Level setting "
::= { fxoPerPortConfigControlEntry 3 }
fxoPerPortConfigControlDetected-Pulse-Decode-Level OBJECT-TYPE
SYNTAX FXOPulseDecodeLevel
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Detected Pulse Decode Level by Pulse Decode Level Scan "
::= { fxoPerPortConfigControlEntry 4 }
fxoPerPortConfigControlTx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { fxoPerPortConfigControlEntry 5 }
fxoPerPortConfigControlRx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { fxoPerPortConfigControlEntry 6 }
--
-- FXO Port Status Table
--
fxoPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Port Status Table"
::= { fxo-card 4 }
fxoPortStatusEntry OBJECT-TYPE
SYNTAX FxoPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Port Status entry"
INDEX { fxoPortStatusIndex ,
fxoPortStatusItemIndex ,
fxoPortStatusPortIndex }
::= { fxoPortStatusTable 1 }
FxoPortStatusEntry ::= SEQUENCE {
fxoPortStatusIndex LargeSlotIndex,
fxoPortStatusItemIndex INTEGER,
fxoPortStatusPortIndex TwelvePortID,
fxoPortStatusStatus INTEGER
}
fxoPortStatusIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoPortStatusEntry 1 }
fxoPortStatusItemIndex OBJECT-TYPE
SYNTAX INTEGER {
ringing(1),
off-hook(2),
tip-open(3),
line-broken(4),
ring-gnd(5),
batt-rev(6),
pulse-on(7),
alarm-on(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ringing, off-hook, tip-open, line-broken, ring-gnd, batt-rev, pulse-on, alarm-on"
::= { fxoPortStatusEntry 2 }
fxoPortStatusPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" port index 1-12 "
::= { fxoPortStatusEntry 3 }
fxoPortStatusStatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Status "
::= { fxoPortStatusEntry 4 }
--
-- FXO Line Diagnostic Control Table
--
fxoDiagTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Diagnostic Control Table."
::= { fxo-card 5 }
fxoDiagTestControlEntry OBJECT-TYPE
SYNTAX FxoDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of FXO diagnostic control table."
INDEX { fxoDiagTestControlIndex }
::= { fxoDiagTestControlTable 1 }
FxoDiagTestControlEntry ::= SEQUENCE {
fxoDiagTestControlIndex LargeSlotIndex,
fxoDiagTestControlType INTEGER,
fxoDiagTestControlRemainTime INTEGER
}
fxoDiagTestControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoDiagTestControlEntry 1 }
fxoDiagTestControlType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
off-hook-test(2),
pulse-decode-level-scan(3),
apply-detected-pulse-decode-level(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXO Test Button"
::= { fxoDiagTestControlEntry 2 }
fxoDiagTestControlRemainTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remain time (sec)"
::= { fxoDiagTestControlEntry 3 }
--
-- FXO Command Control Table
--
fxoCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { fxo-card 6 }
fxoCommandControlEntry OBJECT-TYPE
SYNTAX FxoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { fxoCommandControlIndex }
::= { fxoCommandControlTable 1 }
FxoCommandControlEntry ::= SEQUENCE {
fxoCommandControlIndex LargeSlotIndex,
fxoCommandControlReset INTEGER,
fxoCommandControlLoadDefault INTEGER
}
fxoCommandControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoCommandControlEntry 1 }
fxoCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default FXO CONF"
::= { fxoCommandControlEntry 2 }
fxoCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: FXO Card Reset"
::= { fxoCommandControlEntry 3 }
-- FXO Per Port Signaling Config Control Table
fxoNewPerPortSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoNewPerPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Signaling Configuration Control Table"
::= { fxo-card 7 }
fxoNewPerPortSigSetEntry OBJECT-TYPE
SYNTAX FxoNewPerPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per port signaling configuration control entry"
INDEX { fxoNewPerPortSigSetIndex ,
fxoNewPerPortSigSetPort ,
fxoNewPerPortSigSetItemIndex }
::= { fxoNewPerPortSigSetTable 1 }
FxoNewPerPortSigSetEntry ::= SEQUENCE {
fxoNewPerPortSigSetIndex LargeSlotIndex,
fxoNewPerPortSigSetPort TwelvePortID,
fxoNewPerPortSigSetItemIndex INTEGER,
fxoNewPerPortSigSetSigBit DisplayString
}
fxoNewPerPortSigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoNewPerPortSigSetEntry 1 }
fxoNewPerPortSigSetPort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxoNewPerPortSigSetEntry 2 }
fxoNewPerPortSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
ringing(1),
no-ring(2),
batt-rev(3),
pulse-on(4),
tip-open(5),
off-hook(6),
oos-alarm(7),
ring-gnd(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ringing, no-ring, batt-rev, pulse-on, tip-open, off-hook, oos-on, ring-gnd "
::= { fxoNewPerPortSigSetEntry 3 }
fxoNewPerPortSigSetSigBit OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { fxoNewPerPortSigSetEntry 4 }
--
-- FXO SigMode Control Table
--
fxoNewSigModeControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoNewSigModeControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SigMode control table."
::= { fxo-card 8 }
fxoNewSigModeControlEntry OBJECT-TYPE
SYNTAX FxoNewSigModeControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the SigMode control table."
INDEX { fxoNewSigModeControlIndex }
::= { fxoNewSigModeControlTable 1 }
FxoNewSigModeControlEntry ::= SEQUENCE {
fxoNewSigModeControlIndex LargeSlotIndex,
fxoNewSigModeControlMode INTEGER
}
fxoNewSigModeControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoNewSigModeControlEntry 1 }
fxoNewSigModeControlMode OBJECT-TYPE
SYNTAX INTEGER {
perCard(1),
perPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SigMode Mode"
::= { fxoNewSigModeControlEntry 2 }
--
-- FXO NEW Per Port Config Control Table
--
fxoNewPerPortSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoNewPerPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO New Per Port Configuration Control Table"
::= { fxo-card 9 }
fxoNewPerPortSetEntry OBJECT-TYPE
SYNTAX FxoNewPerPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Configuration control entry"
INDEX { fxoNewPerPortSetIndex ,
fxoNewPerPortSetPortIndex }
::= { fxoNewPerPortSetTable 1 }
FxoNewPerPortSetEntry ::= SEQUENCE {
fxoNewPerPortSetIndex LargeSlotIndex,
fxoNewPerPortSetPortIndex TwelvePortID,
fxoNewPerPortSetTrunk INTEGER,
fxoNewPerPortSetPolarity INTEGER
}
fxoNewPerPortSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoNewPerPortSetEntry 1 }
fxoNewPerPortSetPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxoNewPerPortSetEntry 2 }
fxoNewPerPortSetTrunk OBJECT-TYPE
SYNTAX INTEGER {
onHook(1),
offHook(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port Trunk Condition "
::= { fxoNewPerPortSetEntry 3 }
fxoNewPerPortSetPolarity OBJECT-TYPE
SYNTAX INTEGER {
reverse(1),
normal(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per Port Line polarity "
::= { fxoNewPerPortSetEntry 4 }
--
-- FXOA Per Port Diag InfoTable
--
fxoNewInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoNewInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"E&M Diag Info Table"
::= { fxo-card 10 }
fxoNewInfoEntry OBJECT-TYPE
SYNTAX FxoNewInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Diag Infoentry"
INDEX { fxoNewInfoIndex ,
fxoNewInfoPortIndex }
::= { fxoNewInfoTable 1 }
FxoNewInfoEntry ::= SEQUENCE {
fxoNewInfoIndex LargeSlotIndex,
fxoNewInfoPortIndex TwelvePortID,
fxoNewInfoRing EMOffOn,
fxoNewInfoOffHook EMOffOn,
fxoNewInfoLine EMOffOn,
fxoNewInfoRingGND EMOffOn,
fxoNewInfoBattRev EMOffOn,
fxoNewInfoPulseOn EMOffOn,
fxoNewInfoAlarm EMOffOn,
fxoNewInfoTx DisplayString,
fxoNewInfoRx DisplayString,
fxoNewInfoVoltage DisplayString
}
fxoNewInfoIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoNewInfoEntry 1 }
fxoNewInfoPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxoNewInfoEntry 2 }
fxoNewInfoRing OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ring "
::= { fxoNewInfoEntry 3}
fxoNewInfoOffHook OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" off hook "
::= { fxoNewInfoEntry 4}
fxoNewInfoLine OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" line broken "
::= { fxoNewInfoEntry 5}
fxoNewInfoRingGND OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ring ground "
::= { fxoNewInfoEntry 6}
fxoNewInfoBattRev OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Battery reverse "
::= { fxoNewInfoEntry 7}
fxoNewInfoPulseOn OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Pulse On "
::= { fxoNewInfoEntry 8}
fxoNewInfoAlarm OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm"
::= { fxoNewInfoEntry 9}
fxoNewInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { fxoNewInfoEntry 10 }
fxoNewInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { fxoNewInfoEntry 11}
fxoNewInfoVoltage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port Line Voltage"
::= { fxoNewInfoEntry 12}
--
-- FXOA Line Diagnostic Control Table
--
fxoNewDiagSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoNewDiagSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXOA Diagnostic Control Table."
::= { fxo-card 11 }
fxoNewDiagSetEntry OBJECT-TYPE
SYNTAX FxoNewDiagSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of FXO diagnostic control table."
INDEX { fxoNewDiagSetSlot }
::= { fxoNewDiagSetTable 1 }
FxoNewDiagSetEntry ::= SEQUENCE {
fxoNewDiagSetSlot LargeSlotIndex,
fxoNewDiagSetTest INTEGER,
fxoNewDiagSetPeriod INTEGER,
fxoNewDiagSetRemain INTEGER
}
fxoNewDiagSetSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoNewDiagSetEntry 1 }
fxoNewDiagSetTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
offHookTest(2),
ringTest(3),
battRevTest(4),
pulseOnTest(5),
tipOpenTest(6),
loopback(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { fxoNewDiagSetEntry 2 }
fxoNewDiagSetPeriod OBJECT-TYPE
SYNTAX INTEGER {
sec10(1),
sec60(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Test Button"
::= { fxoNewDiagSetEntry 3 }
fxoNewDiagSetRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { fxoNewDiagSetEntry 4 }
--
-- FXO Per Port Enable/Disable Control Table
--
fxoPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Enable Table"
::= { fxo-card 12 }
fxoPortEnableEntry OBJECT-TYPE
SYNTAX FxoPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FXO Per Port Enable entry"
INDEX { fxoPortEnableIndex ,
fxoPortEnablePort }
::= { fxoPortEnableTable 1 }
FxoPortEnableEntry ::= SEQUENCE {
fxoPortEnableIndex LargeSlotIndex,
fxoPortEnablePort TwelvePortID,
fxoPortEnable INTEGER
}
fxoPortEnableIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoPortEnableEntry 1 }
fxoPortEnablePort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { fxoPortEnableEntry 2 }
fxoPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" port enable/disable"
::= { fxoPortEnableEntry 3 }
--
-- FXOA Line Diagnostic Control Table
--
fxoBertControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FXOA Bert Control Table."
::= { fxo-card 13 }
fxoBertControlEntry OBJECT-TYPE
SYNTAX FxoBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of FXO Bert control table."
INDEX { fxoBertControlSlot }
::= { fxoBertControlTable 1 }
FxoBertControlEntry ::= SEQUENCE {
fxoBertControlSlot LargeSlotIndex,
fxoBertControlMode INTEGER,
fxoBertControlPort INTEGER,
fxoBertControlType INTEGER,
-- fxoBertControlSpilt INTEGER,
fxoBertControlPattern DisplayString,
fxoBertControlPeriod INTEGER,
fxoBertControlStatus INTEGER,
fxoBertControlSync INTEGER,
fxoBertControlError INTEGER,
fxoBertControlTime INTEGER,
fxoBertControlES INTEGER,
fxoBertControlSES INTEGER,
fxoBertControlUS INTEGER
}
fxoBertControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoBertControlEntry 1 }
fxoBertControlMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
bert(2),
loopback(3),
reset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Mode Select"
::= { fxoBertControlEntry 2 }
fxoBertControlPort OBJECT-TYPE
SYNTAX INTEGER{
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
p9(9),
p10(10),
p11(11),
p12(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Port"
::= { fxoBertControlEntry 3 }
fxoBertControlType OBJECT-TYPE
SYNTAX INTEGER {
--off(1),
prbs2exp20of1(2),
prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5),
userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { fxoBertControlEntry 4 }
-- fxoBertControlSpilt OBJECT-TYPE
-- SYNTAX INTEGER {
-- sendAIS(1),
-- no(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert Spilt Mode"
-- ::= { fxoBertControlEntry 5 }
fxoBertControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert User Pattern"
::= { fxoBertControlEntry 6 }
fxoBertControlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { fxoBertControlEntry 7 }
fxoBertControlStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bert(2),
loopback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { fxoBertControlEntry 8 }
fxoBertControlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { fxoBertControlEntry 9 }
fxoBertControlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { fxoBertControlEntry 10 }
fxoBertControlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { fxoBertControlEntry 11 }
fxoBertControlES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Error Second"
::= { fxoBertControlEntry 12 }
fxoBertControlSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert SES"
::= { fxoBertControlEntry 13 }
fxoBertControlUS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Unsync Second"
::= { fxoBertControlEntry 14 }
--
-- FXOA Self Test Control Table
--
fxoSelfTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FxoSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"FXO SelfTest Control Table."
::= { fxo-card 14 }
fxoSelfTestControlEntry OBJECT-TYPE
SYNTAX FxoSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of FXO SelfTest control table."
INDEX { fxoSelfTestSlot }
::= { fxoSelfTestControlTable 1 }
FxoSelfTestControlEntry ::= SEQUENCE {
fxoSelfTestSlot LargeSlotIndex,
fxoSelfTestP1 INTEGER,
fxoSelfTestP2 INTEGER,
fxoSelfTestP3 INTEGER,
fxoSelfTestP4 INTEGER,
fxoSelfTestP5 INTEGER,
fxoSelfTestP6 INTEGER,
fxoSelfTestP7 INTEGER,
fxoSelfTestP8 INTEGER,
fxoSelfTestP9 INTEGER,
fxoSelfTestP10 INTEGER,
fxoSelfTestP11 INTEGER,
fxoSelfTestP12 INTEGER,
fxoSelfTestConfirm INTEGER,
fxoSelfTestStatus INTEGER,
fxoSelfTestResult DisplayString,
fxoSelfTestTestType1 INTEGER,
fxoSelfTestTestRes1 DisplayString,
fxoSelfTestTestType2 INTEGER,
fxoSelfTestTestRes2 DisplayString,
fxoSelfTestTestType3 INTEGER,
fxoSelfTestTestRes3 DisplayString
}
fxoSelfTestSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fxoSelfTestControlEntry 1 }
fxoSelfTestP1 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 2 }
fxoSelfTestP2 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 3 }
fxoSelfTestP3 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 4 }
fxoSelfTestP4 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 5 }
fxoSelfTestP5 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 6 }
fxoSelfTestP6 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 7 }
fxoSelfTestP7 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 8 }
fxoSelfTestP8 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 9 }
fxoSelfTestP9 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 10 }
fxoSelfTestP10 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { fxoSelfTestControlEntry 11 }
fxoSelfTestP11 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 12 }
fxoSelfTestP12 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 13 }
fxoSelfTestConfirm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { fxoSelfTestControlEntry 14 }
fxoSelfTestStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
testing(2),
finish(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxoSelfTestControlEntry 15 }
fxoSelfTestResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxoSelfTestControlEntry 16 }
fxoSelfTestTestType1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
onHookVoltTest(2),
offHookVoltTest(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxoSelfTestControlEntry 17 }
fxoSelfTestTestRes1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxoSelfTestControlEntry 18 }
fxoSelfTestTestType2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
onHookVoltTest(2),
offHookVoltTest(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxoSelfTestControlEntry 19 }
fxoSelfTestTestRes2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxoSelfTestControlEntry 20 }
fxoSelfTestTestType3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
onHookVoltTest(2),
offHookVoltTest(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { fxoSelfTestControlEntry 21 }
fxoSelfTestTestRes3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { fxoSelfTestControlEntry 22 }
fxoTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of FXO"
::= { fxo-card 100 }
--======================================================================--
--======================================================================--
-- mag-card MIB
--======================================================================--
-- Magneto Card
-- magAllPortConfigControlTable OBJECT IDENTIFIER ::= { mag-card 1 }
-- magAllPortSigConfigControlTable OBJECT IDENTIFIER ::= { mag-card 2 }
-- magPerPortConfigControlTable OBJECT IDENTIFIER ::= { mag-card 3 }
-- magPortStatusTable OBJECT IDENTIFIER ::= { mag-card 4 }
-- magDiagTestControlTable OBJECT IDENTIFIER ::= { mag-card 5 }
-- magCommandControlTable OBJECT IDENTIFIER ::= { mag-card 6 }
--======================================================================--
--
-- MAG All Port Config Control Table
--
magAllPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG All Port Configuration Control Table"
::= { mag-card 1 }
magAllPortConfigControlEntry OBJECT-TYPE
SYNTAX MagAllPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG all port configuration control entry"
INDEX { magAllPortConfigControlIndex }
::= { magAllPortConfigControlTable 1 }
MagAllPortConfigControlEntry ::= SEQUENCE {
magAllPortConfigControlIndex LargeSlotIndex,
magAllPortConfigControlRing-Mode INTEGER,
magAllPortConfigControlA-u-law INTEGER,
magAllPortConfigControlImpedance INTEGER,
magAllPortConfigControlTx-gain DisplayString,
magAllPortConfigControlRx-gain DisplayString,
magAllPortConfigControlRing-cadence INTEGER
}
magAllPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magAllPortConfigControlEntry 1 }
magAllPortConfigControlRing-Mode OBJECT-TYPE
SYNTAX INTEGER {
ring-across-l1-l2-only(2),
ring-across-l1-gnd-only(3),
ring-across-l1-l2-and-l1-gnd(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Ring Mode "
::= { magAllPortConfigControlEntry 2 }
magAllPortConfigControlA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { magAllPortConfigControlEntry 3 }
magAllPortConfigControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { magAllPortConfigControlEntry 4 }
magAllPortConfigControlTx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TX-GAIN "
::= { magAllPortConfigControlEntry 5 }
magAllPortConfigControlRx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RX-GAIN "
::= { magAllPortConfigControlEntry 6 }
magAllPortConfigControlRing-cadence OBJECT-TYPE
SYNTAX INTEGER {
cadence-1-on-2-off(1),
cadence-2-on-4-off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ring Cadence "
::= { magAllPortConfigControlEntry 7 }
--
-- MAG All Port Signaling Config Control Table
--
magAllPortSigConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG All Port Signaling Configuration Control Table"
::= { mag-card 2 }
magAllPortSigConfigControlEntry OBJECT-TYPE
SYNTAX MagAllPortSigConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG all port signaling configuration control entry"
INDEX { magAllPortSigConfigControlIndex ,
magAllPortSigConfigControlItemIndex ,
magAllPortSigConfigControlSigBitIndex }
::= { magAllPortSigConfigControlTable 1 }
MagAllPortSigConfigControlEntry ::= SEQUENCE {
magAllPortSigConfigControlIndex LargeSlotIndex,
magAllPortSigConfigControlItemIndex INTEGER,
magAllPortSigConfigControlSigBitIndex INTEGER,
magAllPortSigConfigControlSigBit INTEGER
}
magAllPortSigConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magAllPortSigConfigControlEntry 1 }
magAllPortSigConfigControlItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-ring-l1-l2(1),
tx-ring-l1-gnd(2),
plar-tx-ring-l1-l2(3),
plar-tx-ring-l1-gnd(4),
no-tx-ring(5),
rx-ring-l1-l2(6),
rx-ring-l1-gnd(7),
plar-rx-ring-l1-l2(8),
plar-rx-ring-l1-gnd(9),
oos-alarm(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { magAllPortSigConfigControlEntry 2 }
magAllPortSigConfigControlSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { magAllPortSigConfigControlEntry 3 }
magAllPortSigConfigControlSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { magAllPortSigConfigControlEntry 4 }
--
-- MAG Per Port Config Control Table
--
magPerPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Per Port Configuration Control Table"
::= { mag-card 3 }
magPerPortConfigControlEntry OBJECT-TYPE
SYNTAX MagPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Per Port Configuration control entry"
INDEX { magPerPortConfigControlIndex ,
magPerPortConfigControlPortIndex }
::= { magPerPortConfigControlTable 1 }
MagPerPortConfigControlEntry ::= SEQUENCE {
magPerPortConfigControlIndex LargeSlotIndex,
magPerPortConfigControlPortIndex TwelvePortID,
magPerPortConfigControlPLAR INTEGER
}
magPerPortConfigControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magPerPortConfigControlEntry 1 }
magPerPortConfigControlPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { magPerPortConfigControlEntry 2 }
magPerPortConfigControlPLAR OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port PLAR setting "
::= { magPerPortConfigControlEntry 3 }
--
-- MAG Port Status Table
--
magPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Port Status Table"
::= { mag-card 4 }
magPortStatusEntry OBJECT-TYPE
SYNTAX MagPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Port Status entry"
INDEX { magPortStatusIndex ,
magPortStatusItemIndex ,
magPortStatusPortIndex }
::= { magPortStatusTable 1 }
MagPortStatusEntry ::= SEQUENCE {
magPortStatusIndex LargeSlotIndex,
magPortStatusItemIndex INTEGER,
magPortStatusPortIndex TwelvePortID,
magPortStatusStatus INTEGER
}
magPortStatusIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magPortStatusEntry 1 }
magPortStatusItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-ring-l1-l2(1),
tx-ring-l1-gnd(2),
rx-ring-l1-l2(3),
rx-ring-l1-gnd(4),
plar-on(5),
alarm-on(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { magPortStatusEntry 2 }
magPortStatusPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" port index 1-12 "
::= { magPortStatusEntry 3 }
magPortStatusStatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Status "
::= { magPortStatusEntry 4 }
--
-- MAG Line Diagnostic Control Table
--
magDiagTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Diagnostic Control Table."
::= { mag-card 5 }
magDiagTestControlEntry OBJECT-TYPE
SYNTAX MagDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of MAG diagnostic control table."
INDEX { magDiagTestControlIndex }
::= { magDiagTestControlTable 1 }
MagDiagTestControlEntry ::= SEQUENCE {
magDiagTestControlIndex LargeSlotIndex,
magDiagTestControlType INTEGER,
magDiagTestControlRemainTime INTEGER
}
magDiagTestControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magDiagTestControlEntry 1 }
magDiagTestControlType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
rx-ring-l1-l2-test(2),
rx-ring-l1-gnd-test(3),
tx-ring-test(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAG Test"
::= { magDiagTestControlEntry 2 }
magDiagTestControlRemainTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remain time (sec)"
::= { magDiagTestControlEntry 3 }
--
-- MAG Command Control Table
--
magCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { mag-card 6 }
magCommandControlEntry OBJECT-TYPE
SYNTAX MagCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { magCommandControlIndex }
::= { magCommandControlTable 1 }
MagCommandControlEntry ::= SEQUENCE {
magCommandControlIndex LargeSlotIndex,
magCommandControlReset INTEGER,
magCommandControlLoadDefault INTEGER
}
magCommandControlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magCommandControlEntry 1 }
magCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default MAG CONF"
::= { magCommandControlEntry 2 }
magCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: MAG Card Reset"
::= { magCommandControlEntry 3 }
--
-- MAG-A All Port Config Control Table
--
magaAllPortSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaAllPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A All Port Configuration Control Table"
::= { mag-card 7 }
magaAllPortSetEntry OBJECT-TYPE
SYNTAX MagaAllPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A all port configuration control entry"
INDEX { magaAllPortSetIndex }
::= { magaAllPortSetTable 1 }
MagaAllPortSetEntry ::= SEQUENCE {
magaAllPortSetIndex LargeSlotIndex,
magaAllPortSetAuLaw INTEGER,
magaAllPortSetImpedance INTEGER
}
magaAllPortSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaAllPortSetEntry 1 }
magaAllPortSetAuLaw OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { magaAllPortSetEntry 2 }
magaAllPortSetImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { magaAllPortSetEntry 3 }
--
-- MAG-A All Port Signaling Config Control Table
--
magaSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A All Port Signaling Configuration Control Table"
::= { mag-card 8 }
magaSigSetEntry OBJECT-TYPE
SYNTAX MagaSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" MAG-A all port signaling configuration control entry"
INDEX { magaSigSetIndex ,
magaSigSetItemIndex ,
magaSigSetSigBitIndex }
::= { magaSigSetTable 1 }
MagaSigSetEntry ::= SEQUENCE {
magaSigSetIndex LargeSlotIndex,
magaSigSetItemIndex INTEGER,
magaSigSetSigBitIndex INTEGER,
magaSigSetSigBit INTEGER
}
magaSigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaSigSetEntry 1 }
magaSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
crankStop(1),
crankStart(2),
crankStartPLAR(3),
noRing(4),
ringing(5),
plarRinging(6),
oosAlarm(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MAG-A signaling setup "
::= { magaSigSetEntry 2 }
magaSigSetSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { magaSigSetEntry 3 }
magaSigSetSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { magaSigSetEntry 4 }
--
-- MAG-A Per Port Config Control Table
--
magaPortSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A Per Port Configuration Control Table"
::= { mag-card 9 }
magaPortSetEntry OBJECT-TYPE
SYNTAX MagaPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A Per Port Configuration control entry"
INDEX { magaPortSetIndex ,
magaPortSetPortIndex }
::= { magaPortSetTable 1 }
MagaPortSetEntry ::= SEQUENCE {
magaPortSetIndex LargeSlotIndex,
magaPortSetPortIndex TwelvePortID ,
magaPortSetTxGain DisplayString,
magaPortSetRxGain DisplayString,
magaPortSetPLAR INTEGER,
magaPortStopWatch INTEGER,
magaPortPLARStopWatch INTEGER,
magaPortSetRingerLine INTEGER
}
magaPortSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaPortSetEntry 1 }
magaPortSetPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { magaPortSetEntry 2 }
magaPortSetTxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { magaPortSetEntry 3 }
magaPortSetRxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { magaPortSetEntry 4 }
magaPortSetPLAR OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port PLAR setting "
::= { magaPortSetEntry 5 }
magaPortStopWatch OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" StopWatch N/A, 0.7s, 1.0s, 1.5s, 2.0s "
::= { magaPortSetEntry 6 }
magaPortPLARStopWatch OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" StopWatch Plar N/A, 0.7s, 1.0s, 1.5s, 2.0s "
::= { magaPortSetEntry 7 }
magaPortSetRingerLine OBJECT-TYPE
SYNTAX INTEGER {
l1-l2(1),
l1-gnd(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ringer Across Line "
::= { magaPortSetEntry 8 }
--
-- MAG-A Per Port Diag InfoTable
--
magaDiagInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A Diag Info Table"
::= { mag-card 10 }
magaDiagInfoEntry OBJECT-TYPE
SYNTAX MagaDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A Diag Infoentry"
INDEX { magaDiagInfoIndex ,
magaDiagInfoPort }
::= { magaDiagInfoTable 1 }
MagaDiagInfoEntry ::= SEQUENCE {
magaDiagInfoIndex LargeSlotIndex,
magaDiagInfoPort TwelvePortID ,
magaDiagInfoAuLaw INTEGER,
magaDiagInfoIMP INTEGER,
magaDiagInfoCrank EMOffOn,
magaDiagInfoRingSig EMOffOn,
magaDiagInfoAIS EMOffOn,
magaDiagInfoOOS EMOffOn,
magaDiagInfoRingerLine INTEGER,
magaDiagInfoRingDuration INTEGER,
magaDiagInfoPlar INTEGER,
magaDiagInfoInputPW INTEGER,
magaDiagInfoPWStatus INTEGER,
magaDiagInfoRingerGen INTEGER,
magaDiagInfoRingerStatus INTEGER,
magaDiagInfoTx DisplayString,
magaDiagInfoRx DisplayString
}
magaDiagInfoIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaDiagInfoEntry 1 }
magaDiagInfoPort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { magaDiagInfoEntry 2 }
magaDiagInfoAuLaw OBJECT-TYPE
SYNTAX INTEGER {
aLaw(1),
uLaw(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" A u Law"
::= { magaDiagInfoEntry 3}
magaDiagInfoIMP OBJECT-TYPE
SYNTAX INTEGER {
imp900(1),
imp600(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Impedance"
::= { magaDiagInfoEntry 4}
magaDiagInfoCrank OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Crank "
::= { magaDiagInfoEntry 5}
magaDiagInfoRingSig OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Ring Signal "
::= { magaDiagInfoEntry 6}
magaDiagInfoAIS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" AIS alarm"
::= { magaDiagInfoEntry 7}
magaDiagInfoOOS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OOS alarm "
::= { magaDiagInfoEntry 8}
magaDiagInfoRingerLine OBJECT-TYPE
SYNTAX INTEGER {
l1-l2(1),
l1-gnd(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { magaDiagInfoEntry 9}
magaDiagInfoRingDuration OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Ring Duration"
::= { magaDiagInfoEntry 10}
magaDiagInfoPlar OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" PLAR "
::= { magaDiagInfoEntry 11}
magaDiagInfoInputPW OBJECT-TYPE
SYNTAX INTEGER {
plusMinus48v(1),
plusMinus24v(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" INPUT POWER"
::= { magaDiagInfoEntry 12}
magaDiagInfoPWStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { magaDiagInfoEntry 13}
magaDiagInfoRingerGen OBJECT-TYPE
SYNTAX INTEGER {
vac-76-and-16-7Hz(1),
vac-76-and-20-0Hz(2),
vac-76-and-50-0Hz(3),
vac-76-and-25-0Hz(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" RingerGen"
::= { magaDiagInfoEntry 14}
magaDiagInfoRingerStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { magaDiagInfoEntry 15}
magaDiagInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { magaDiagInfoEntry 16 }
magaDiagInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { magaDiagInfoEntry 17}
--
-- MAG-A Line Diagnostic Control Table
--
magaDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG-A Diagnostic Control Table."
::= { mag-card 11 }
magaDiagControlEntry OBJECT-TYPE
SYNTAX MagaDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of MAG-A diagnostic control table."
INDEX { magaDiagControlSlot }
::= { magaDiagControlTable 1 }
MagaDiagControlEntry ::= SEQUENCE {
magaDiagControlSlot LargeSlotIndex,
magaDiagControlTest INTEGER,
magaDiagControlRemain INTEGER
}
magaDiagControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaDiagControlEntry 1 }
magaDiagControlTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
crank-test(2),
ring-test(3),
channel-swap(4),
loopback(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAG-A Test Button"
::= { magaDiagControlEntry 2 }
magaDiagControlRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { magaDiagControlEntry 3 }
--
-- MAGA Per Port Enable/Disable Control Table
--
magaPortEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagaPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAGA Per Port Enable Table"
::= { mag-card 12 }
magaPortEnableEntry OBJECT-TYPE
SYNTAX MagaPortEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAGA Per Port Enable entry"
INDEX { magaPortEnableIndex ,
magaPortEnablePort }
::= { magaPortEnableTable 1 }
MagaPortEnableEntry ::= SEQUENCE {
magaPortEnableIndex LargeSlotIndex,
magaPortEnablePort TwelvePortID,
magaPortEnable INTEGER
}
magaPortEnableIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magaPortEnableEntry 1 }
magaPortEnablePort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { magaPortEnableEntry 2 }
magaPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" port enable/disable"
::= { magaPortEnableEntry 3 }
-- MAG Per Port Signaling Config Control Table
magPortSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Per Port Signaling Configuration Control Table"
::= { mag-card 13}
magPortSigSetEntry OBJECT-TYPE
SYNTAX MagPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAG Per port signaling configuration control entry"
INDEX { magPortSigSetIndex ,
magPortSigSetPort ,
magPortSigSetItemIndex }
::= { magPortSigSetTable 1 }
MagPortSigSetEntry ::= SEQUENCE {
magPortSigSetIndex LargeSlotIndex,
magPortSigSetPort TwelvePortID,
magPortSigSetItemIndex INTEGER,
magPortSigSetSigBit DisplayString
}
magPortSigSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magPortSigSetEntry 1 }
magPortSigSetPort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { magPortSigSetEntry 2 }
magPortSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
crankStop(1),
crankStart(2),
crankStartPLAR(3),
noRing(4),
ringing(5),
plarRinging(6),
oosAlarm(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" MAG-A signaling setup "
::= { magPortSigSetEntry 3 }
magPortSigSetSigBit OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { magPortSigSetEntry 4 }
--
-- MAG SetupMode Control Table
--
magSetupModeSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Setup Mode control table."
::= { mag-card 14 }
magSetupModeSetEntry OBJECT-TYPE
SYNTAX MagSetupModeSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Setup Mode control table."
INDEX { magSetupModeSetIndex }
::= { magSetupModeSetTable 1 }
MagSetupModeSetEntry ::= SEQUENCE {
magSetupModeSetIndex LargeSlotIndex,
magSetupModeSetSigMode INTEGER
}
magSetupModeSetIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magSetupModeSetEntry 1 }
magSetupModeSetSigMode OBJECT-TYPE
SYNTAX INTEGER {
perCard(1),
perPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SigMode Mode"
::= { magSetupModeSetEntry 2 }
--
-- MAG-A Bert Control Table
--
magBertControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MAG-A Bert Control Table."
::= { mag-card 15 }
magBertControlEntry OBJECT-TYPE
SYNTAX MagBertControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of MAG-A Bert control table."
INDEX { magBertControlSlot }
::= { magBertControlTable 1 }
MagBertControlEntry ::= SEQUENCE {
magBertControlSlot LargeSlotIndex,
magBertControlMode INTEGER,
magBertControlPort INTEGER,
magBertControlType INTEGER,
-- magBertControlSpilt INTEGER,
magBertControlPattern DisplayString,
magBertControlPeriod INTEGER,
magBertControlStatus INTEGER,
magBertControlSync INTEGER,
magBertControlError INTEGER,
magBertControlTime INTEGER,
magBertControlES INTEGER,
magBertControlSES INTEGER,
magBertControlUS INTEGER
}
magBertControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magBertControlEntry 1 }
magBertControlMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
bert(2),
loopback(3),
reset(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Mode Select"
::= { magBertControlEntry 2 }
magBertControlPort OBJECT-TYPE
SYNTAX INTEGER{
p1(1),
p2(2),
p3(3),
p4(4),
p5(5),
p6(6),
p7(7),
p8(8),
p9(9),
p10(10),
p11(11),
p12(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Port"
::= { magBertControlEntry 3 }
magBertControlType OBJECT-TYPE
SYNTAX INTEGER {
na(1), --//RIKER2021 SilverCreek
prbs2exp20of1(2),
prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5),
userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { magBertControlEntry 4 }
-- magBertControlSpilt OBJECT-TYPE
-- SYNTAX INTEGER {
-- sendAIS(1),
-- no(2)
-- }
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert Spilt Mode"
-- ::= { magBertControlEntry 5 }
magBertControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert User Pattern"
::= { magBertControlEntry 6 }
magBertControlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { magBertControlEntry 7 }
magBertControlStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bert(2),
loopback(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { magBertControlEntry 8 }
magBertControlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { magBertControlEntry 9 }
magBertControlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { magBertControlEntry 10 }
magBertControlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { magBertControlEntry 11 }
magBertControlES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Error Second"
::= { magBertControlEntry 12 }
magBertControlSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert SES"
::= { magBertControlEntry 13 }
magBertControlUS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bert Unsync Second"
::= { magBertControlEntry 14 }
--
-- MAG-A Self Test Control Table
--
magSelfTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MagSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MAG-A SelfTest Control Table."
::= { mag-card 16 }
magSelfTestControlEntry OBJECT-TYPE
SYNTAX MagSelfTestControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of MAG-A SelfTest control table."
INDEX { magSelfTestSlot }
::= { magSelfTestControlTable 1 }
MagSelfTestControlEntry ::= SEQUENCE {
magSelfTestSlot LargeSlotIndex,
magSelfTestP1 INTEGER,
magSelfTestP2 INTEGER,
magSelfTestP3 INTEGER,
magSelfTestP4 INTEGER,
magSelfTestP5 INTEGER,
magSelfTestP6 INTEGER,
magSelfTestP7 INTEGER,
magSelfTestP8 INTEGER,
magSelfTestP9 INTEGER,
magSelfTestP10 INTEGER,
magSelfTestP11 INTEGER,
magSelfTestP12 INTEGER,
magSelfTestConfirm INTEGER,
magSelfTestStatus INTEGER,
magSelfTestResult DisplayString,
magSelfTestTestType1 INTEGER,
magSelfTestTestRes1 DisplayString,
magSelfTestTestType2 INTEGER,
magSelfTestTestRes2 DisplayString,
magSelfTestTestType3 INTEGER,
magSelfTestTestRes3 DisplayString
}
magSelfTestSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { magSelfTestControlEntry 1 }
magSelfTestP1 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 2 }
magSelfTestP2 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 3 }
magSelfTestP3 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 4 }
magSelfTestP4 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 5 }
magSelfTestP5 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 6 }
magSelfTestP6 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 7 }
magSelfTestP7 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 8 }
magSelfTestP8 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 9 }
magSelfTestP9 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 10 }
magSelfTestP10 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Select"
::= { magSelfTestControlEntry 11 }
magSelfTestP11 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 12 }
magSelfTestP12 OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 13 }
magSelfTestConfirm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port Select"
::= { magSelfTestControlEntry 14 }
magSelfTestStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
testing(2),
finish(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { magSelfTestControlEntry 15 }
magSelfTestResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { magSelfTestControlEntry 16 }
magSelfTestTestType1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
powerTest(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { magSelfTestControlEntry 17 }
magSelfTestTestRes1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { magSelfTestControlEntry 18 }
magSelfTestTestType2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
powerTest(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { magSelfTestControlEntry 19 }
magSelfTestTestRes2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { magSelfTestControlEntry 20 }
magSelfTestTestType3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
powerTest(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port Select"
::= { magSelfTestControlEntry 21 }
magSelfTestTestRes3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Test Result"
::= { magSelfTestControlEntry 22 }
magTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 12MAG"
::= { mag-card 100 }
--======================================================================--
--======================================================================--
-- quad-e1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
qe1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { qe1-card 1 }
qe1LineControlEntry OBJECT-TYPE
SYNTAX QE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1LineControlTable 1 }
QE1LineControlEntry ::= SEQUENCE {
qe1Index LargeSlotIndex,
qe1PortIndex FourPortID,
qe1LineFrame INTEGER,
qe1LineCoding INTEGER,
qe1Interface INTEGER,
qe1FDL INTEGER,
qe1FDLSabit INTEGER,
qe1AIS INTEGER,
qe1RAI INTEGER,
qe1CRC INTEGER,
qe1IdleCode INTEGER,
qe1CASMode INTEGER,
qe1SignallingMode INTEGER,
qe1CGA INTEGER,
qe1OutOfService INTEGER,
qe1Protect INTEGER,
qe1Master INTEGER,
qe1SSMSabit INTEGER,
qe1PortEnable INTEGER
}
qe1Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qe1LineControlEntry 1 }
qe1PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { qe1LineControlEntry 2 }
qe1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { qe1LineControlEntry 3 }
qe1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { qe1LineControlEntry 4 }
qe1Interface OBJECT-TYPE
SYNTAX INTEGER {
twisted-pair(1),
coaxial-cable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that QE1 line use 75/120 Ohm Cable."
::= { qe1LineControlEntry 5 }
qe1FDL OBJECT-TYPE
SYNTAX INTEGER {
fdl(1),
off(2),
hdlc(3),
ssm(4),
ssmHdlc(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 Facility Data Link ON/OFF"
::= { qe1LineControlEntry 6 }
qe1FDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
sa4-5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 Facility Data Link use Sax bit"
::= { qe1LineControlEntry 7 }
qe1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 line Alarm Indication Signal."
::= { qe1LineControlEntry 8 }
qe1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { qe1LineControlEntry 9 }
qe1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 Cycle Redundancy Check ON/OFF"
::= { qe1LineControlEntry 10 }
qe1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { qe1LineControlEntry 11 }
qe1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { qe1LineControlEntry 12 }
qe1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
cd01(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS or CD01"
::= { qe1LineControlEntry 13 }
qe1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { qe1LineControlEntry 14 }
qe1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { qe1LineControlEntry 15 }
qe1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { qe1LineControlEntry 16 }
qe1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { qe1LineControlEntry 17 }
qe1SSMSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
na(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 SSM Sax bit"
::= { qe1LineControlEntry 18 }
qe1PortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE1 port enable/disable"
::= { qe1LineControlEntry 19 }
--
-- User Current Performance Table
--
qe1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { qe1-card 2 }
qe1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX QE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { qe1Index , qe1PortIndex }
::= { qe1UserCurrentPerfTable 1 }
QE1UserCurrentPerfEntry ::= SEQUENCE {
qe1UserCurrentPerfES INTEGER,
qe1UserCurrentPerfSES INTEGER,
qe1UserCurrentPerfBES INTEGER,
qe1UserCurrentPerfUAS INTEGER,
qe1UserCurrentPerfCSS INTEGER,
qe1UserCurrentPerfBPV INTEGER,
qe1UserCurrentPerfDMs INTEGER,
qe1UserCurr15MinTimeElapsed INTEGER,
qe1UserValid15MinInterval INTEGER
}
qe1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1UserCurrentPerfEntry 2 }
qe1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1UserCurrentPerfEntry 3 }
qe1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1UserCurrentPerfEntry 4 }
qe1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1UserCurrentPerfEntry 5 }
qe1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { qe1UserCurrentPerfEntry 6 }
qe1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1UserCurrentPerfEntry 7 }
qe1UserCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1UserCurrentPerfEntry 8 }
qe1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { qe1UserCurrentPerfEntry 11 }
qe1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { qe1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
qe1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { qe1-card 3 }
qe1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX QE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { qe1Index , qe1PortIndex ,
qe1UserIntervalPerfNumber }
::= { qe1UserIntervalPerfTable 1 }
QE1UserIntervalPerfEntry ::= SEQUENCE {
qe1UserIntervalPerfNumber INTEGER (1..96),
qe1UserIntervalPerfES INTEGER,
qe1UserIntervalPerfSES INTEGER,
qe1UserIntervalPerfBES INTEGER,
qe1UserIntervalPerfUAS INTEGER,
qe1UserIntervalPerfCSS INTEGER,
qe1UserIntervalPerfBPV INTEGER,
qe1UserIntervalPerfDMs INTEGER
}
qe1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { qe1UserIntervalPerfEntry 2 }
qe1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1UserIntervalPerfEntry 3 }
qe1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1UserIntervalPerfEntry 4 }
qe1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1UserIntervalPerfEntry 5 }
qe1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1UserIntervalPerfEntry 6 }
qe1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1UserIntervalPerfEntry 7 }
qe1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1UserIntervalPerfEntry 8 }
qe1UserIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
qe1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { qe1-card 4 }
qe1UserTotalPerfEntry OBJECT-TYPE
SYNTAX QE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { qe1Index , qe1PortIndex }
::= { qe1UserTotalPerfTable 1 }
QE1UserTotalPerfEntry ::= SEQUENCE {
qe1UserTotalPerfES INTEGER,
qe1UserTotalPerfSES INTEGER,
qe1UserTotalPerfBES INTEGER,
qe1UserTotalPerfUAS INTEGER,
qe1UserTotalPerfCSS INTEGER,
qe1UserTotalPerfBPV INTEGER,
qe1UserTotalPerfDMs INTEGER
}
qe1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1UserTotalPerfEntry 2 }
qe1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1UserTotalPerfEntry 3 }
qe1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1UserTotalPerfEntry 4 }
qe1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1UserTotalPerfEntry 5 }
qe1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1UserTotalPerfEntry 6 }
qe1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1UserTotalPerfEntry 7 }
qe1UserTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
qe1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { qe1-card 5 }
qe1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX QE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { qe1Index , qe1PortIndex ,
qe1UserDaysIndex }
::= { qe1UserSevenDaysPerfTable 1 }
QE1UserSevenDaysPerfEntry ::= SEQUENCE {
qe1UserDaysIndex INTEGER (1..7),
qe1UserDateStrIndex DisplayString (SIZE (0..255) ),
qe1UserSevenDaysPerfES INTEGER,
qe1UserSevenDaysPerfSES INTEGER,
qe1UserSevenDaysPerfBES INTEGER,
qe1UserSevenDaysPerfUAS INTEGER,
qe1UserSevenDaysPerfCSS INTEGER,
qe1UserSevenDaysPerfDMs INTEGER,
qe1UserSevenDaysPerfBPV INTEGER
}
qe1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { qe1UserSevenDaysPerfEntry 2 }
qe1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { qe1UserSevenDaysPerfEntry 3 }
qe1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1UserSevenDaysPerfEntry 4 }
qe1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1UserSevenDaysPerfEntry 5 }
qe1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1UserSevenDaysPerfEntry 6 }
qe1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1UserSevenDaysPerfEntry 7 }
qe1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1UserSevenDaysPerfEntry 8 }
qe1UserSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1UserSevenDaysPerfEntry 9 }
qe1UserSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1UserSevenDaysPerfEntry 10 }
--
-- Line Current Performance Table
--
qe1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { qe1-card 10 }
qe1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX QE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { qe1Index , qe1PortIndex }
::= { qe1LineCurrentPerfTable 1 }
QE1LineCurrentPerfEntry ::= SEQUENCE {
qe1LineCurrentPerfES INTEGER,
qe1LineCurrentPerfSES INTEGER,
qe1LineCurrentPerfBES INTEGER,
qe1LineCurrentPerfUAS INTEGER,
qe1LineCurrentPerfCSS INTEGER,
qe1LineCurrentPerfBPV INTEGER,
qe1LineCurrentPerfDMs INTEGER,
qe1LineCurr15MinTimeElapsed INTEGER,
qe1LineValid15MinInterval INTEGER
}
qe1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { qe1LineCurrentPerfEntry 2 }
qe1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1LineCurrentPerfEntry 3 }
qe1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1LineCurrentPerfEntry 4 }
qe1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1LineCurrentPerfEntry 5 }
qe1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1LineCurrentPerfEntry 6 }
qe1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1LineCurrentPerfEntry 7 }
qe1LineCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1LineCurrentPerfEntry 8 }
qe1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { qe1LineCurrentPerfEntry 11 }
qe1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { qe1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
qe1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { qe1-card 11 }
qe1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX QE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { qe1Index , qe1PortIndex ,
qe1LineIntervalPerfNumber }
::= { qe1LineIntervalPerfTable 1 }
QE1LineIntervalPerfEntry ::= SEQUENCE {
qe1LineIntervalPerfNumber INTEGER (1..96),
qe1LineIntervalPerfES INTEGER,
qe1LineIntervalPerfSES INTEGER,
qe1LineIntervalPerfBES INTEGER,
qe1LineIntervalPerfUAS INTEGER,
qe1LineIntervalPerfCSS INTEGER,
qe1LineIntervalPerfBPV INTEGER,
qe1LineIntervalPerfDMs INTEGER,
qe1LineIntvAvailable INTEGER
}
qe1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { qe1LineIntervalPerfEntry 2 }
qe1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1LineIntervalPerfEntry 3 }
qe1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1LineIntervalPerfEntry 4 }
qe1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1LineIntervalPerfEntry 5 }
qe1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1LineIntervalPerfEntry 6 }
qe1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1LineIntervalPerfEntry 7 }
qe1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1LineIntervalPerfEntry 8 }
qe1LineIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1LineIntervalPerfEntry 9 }
qe1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { qe1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
qe1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { qe1-card 12 }
qe1LineTotalPerfEntry OBJECT-TYPE
SYNTAX QE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { qe1Index , qe1PortIndex }
::= { qe1LineTotalPerfTable 1 }
QE1LineTotalPerfEntry ::= SEQUENCE {
qe1LineTotalPerfES INTEGER,
qe1LineTotalPerfSES INTEGER,
qe1LineTotalPerfBES INTEGER,
qe1LineTotalPerfUAS INTEGER,
qe1LineTotalPerfCSS INTEGER,
qe1LineTotalPerfBPV INTEGER,
qe1LineTotalPerfDMs INTEGER
}
qe1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1LineTotalPerfEntry 2 }
qe1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1LineTotalPerfEntry 3 }
qe1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1LineTotalPerfEntry 4 }
qe1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1LineTotalPerfEntry 5 }
qe1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1LineTotalPerfEntry 6 }
qe1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1LineTotalPerfEntry 7 }
qe1LineTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
qe1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { qe1-card 13 }
qe1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX QE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { qe1Index , qe1PortIndex ,
qe1LineDaysIndex }
::= { qe1LineSevenDaysPerfTable 1 }
QE1LineSevenDaysPerfEntry ::= SEQUENCE {
qe1LineDaysIndex INTEGER (1..7),
qe1LineDateStrIndex DisplayString (SIZE (0..255) ),
qe1LineSevenDaysPerfES INTEGER,
qe1LineSevenDaysPerfSES INTEGER,
qe1LineSevenDaysPerfBES INTEGER,
qe1LineSevenDaysPerfUAS INTEGER,
qe1LineSevenDaysPerfCSS INTEGER,
qe1LineSevenDaysPerfDMs INTEGER,
qe1LineSevenDaysPerfBPV INTEGER
}
qe1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { qe1LineSevenDaysPerfEntry 2 }
qe1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { qe1LineSevenDaysPerfEntry 3 }
qe1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qe1LineSevenDaysPerfEntry 4 }
qe1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qe1LineSevenDaysPerfEntry 5 }
qe1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qe1LineSevenDaysPerfEntry 6 }
qe1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qe1LineSevenDaysPerfEntry 7 }
qe1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qe1LineSevenDaysPerfEntry 8 }
qe1LineSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { qe1LineSevenDaysPerfEntry 9 }
qe1LineSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qe1LineSevenDaysPerfEntry 10 }
--
-- Alarm Queue Table
--
qe1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { qe1-card 14 }
qe1AlarmQueueEntry OBJECT-TYPE
SYNTAX QE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { qe1Index , qe1PortIndex ,
qe1AlarmQueueIndex }
::= { qe1AlarmQueueTable 1 }
QE1AlarmQueueEntry ::= SEQUENCE {
qe1AlarmQueueIndex INTEGER (1..40),
qe1AlarmQueueString DisplayString (SIZE(0..255))
}
qe1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { qe1AlarmQueueEntry 2 }
qe1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { qe1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
qe1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { qe1-card 15 }
qe1AlarmHistoryEntry OBJECT-TYPE
SYNTAX QE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { qe1Index , qe1PortIndex ,
qe1AlarmHistoryIndex }
::= { qe1AlarmHistoryTable 1 }
QE1AlarmHistoryEntry ::= SEQUENCE {
qe1AlarmHistoryIndex INTEGER,
qe1Threshold INTEGER,
qe1CurrentState INTEGER,
qe1CurrentCount INTEGER,
qe1Alarm AlarmSeverity
}
qe1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
tpca(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { qe1AlarmHistoryEntry 2 }
qe1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { qe1AlarmHistoryEntry 3 }
qe1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
portDisabled(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { qe1AlarmHistoryEntry 4 }
qe1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { qe1AlarmHistoryEntry 5 }
qe1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { qe1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
qe1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { qe1-card 16 }
qe1LineAvailabilityEntry OBJECT-TYPE
SYNTAX QE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1LineAvailabilityTable 1 }
QE1LineAvailabilityEntry ::= SEQUENCE {
qe1AvailableSeconds DisplayString,
qe1UnavailableSeconds DisplayString,
qe1LineAvailability DisplayString
}
qe1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { qe1LineAvailabilityEntry 2 }
qe1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { qe1LineAvailabilityEntry 3 }
qe1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { qe1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
qe1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qe1-card 17 }
qe1AlarmControlEntry OBJECT-TYPE
SYNTAX QE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1AlarmControlTable 1 }
QE1AlarmControlEntry ::= SEQUENCE {
qe1RAI-Line AlarmSeverity,
qe1AIS-Line AlarmSeverity,
qe1LOS-Line AlarmSeverity,
qe1LOF-Line AlarmSeverity,
qe1BPV-Line AlarmSeverity,
qe1ESS-Line AlarmSeverity,
qe1UAS-Line AlarmSeverity,
qe1CSS-Line AlarmSeverity,
qe1TCPA AlarmSeverity
}
qe1RAI-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { qe1AlarmControlEntry 2 }
qe1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { qe1AlarmControlEntry 3 }
qe1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { qe1AlarmControlEntry 4 }
qe1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { qe1AlarmControlEntry 5 }
qe1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { qe1AlarmControlEntry 6 }
qe1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { qe1AlarmControlEntry 7 }
qe1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { qe1AlarmControlEntry 8 }
qe1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { qe1AlarmControlEntry 9 }
-- RIKER 2013 NFS-13000027
qe1TCPA OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold Crossing Performance Alarm"
::= { qe1AlarmControlEntry 10 }
--
-- Threshold Control Table
--
qe1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qe1-card 18 }
qe1ThresholdControlEntry OBJECT-TYPE
SYNTAX QE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1ThresholdControlTable 1 }
QE1ThresholdControlEntry ::= SEQUENCE {
qe1ThresholdBPV-Line INTEGER,
qe1ThresholdESS-Line INTEGER,
qe1ThresholdUAS-Line INTEGER,
qe1ThresholdCSS-Line INTEGER,
qe1ThresholdTCPA INTEGER
}
qe1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line: 10exp-N "
::= { qe1ThresholdControlEntry 2 }
qe1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { qe1ThresholdControlEntry 3 }
qe1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { qe1ThresholdControlEntry 4 }
qe1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { qe1ThresholdControlEntry 5 }
-- RIKER 2013 NFS-13000027
qe1ThresholdTCPA OBJECT-TYPE
SYNTAX INTEGER (1..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of TCPA "
::= { qe1ThresholdControlEntry 6 }
--
-- Line Diagnostic Control Table
--
qe1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qe1-card 19 }
qe1LineDiagControlEntry OBJECT-TYPE
SYNTAX QE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1LineDiagControlTable 1 }
QE1LineDiagControlEntry ::= SEQUENCE {
qe1LoopbackType INTEGER,
qe1LoopbackStatus INTEGER,
qe1PRBSControl INTEGER,
qe1PRBSStatus INTEGER,
qe1PRBSElapseSeconds INTEGER,
qe1PRBSErrorSeconds INTEGER,
qe1PRBSErrorCounts INTEGER,
qe1InbandLoopbackPeriod INTEGER,
qe1remBERTControl INTEGER,
qe1remBERTStatus INTEGER,
qe1remBERTCounter INTEGER,
qe1remBERTElapsed INTEGER,
qe1remBERTErrorSeconds INTEGER,
qe1remBERTPatternUnsyncSeconds INTEGER,
qe1PatternSend INTEGER,
qe1PatternMap DisplayString
}
qe1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-PLB-Active(5),
remote-LLB-Active(6),
remote-PLB-Deactive(7),
remote-LLB-Deactive(8),
remote-DTE1-Active(9),
remote-DTE1-Deactive(10),
remote-DTE2-Active(11),
remote-DTE2-Deactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qe1 Loopback Type"
::= { qe1LineDiagControlEntry 2 }
qe1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qe1 Loopback Status"
::= { qe1LineDiagControlEntry 3 }
qe1PRBSControl OBJECT-TYPE
SYNTAX INTEGER {
prbs-deactive(1),
prbs-active-full(2),
prbs-reset-error-count(3),
prbs-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qe1 PRBS Control"
::= { qe1LineDiagControlEntry 4 }
qe1PRBSStatus OBJECT-TYPE
SYNTAX INTEGER {
prbs-sync(1),
prbs-unsync(2),
prbs-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qe1 PRBS Status"
::= { qe1LineDiagControlEntry 5 }
qe1PRBSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qe1 PRBS Elapse Seconds"
::= { qe1LineDiagControlEntry 6 }
qe1PRBSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qe1 PRBS Error Seconds"
::= { qe1LineDiagControlEntry 7 }
qe1PRBSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qe1 PRBS Error Counts"
::= { qe1LineDiagControlEntry 8 }
qe1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of QE1 inband local, payload, or line loopback"
::= { qe1LineDiagControlEntry 9 }
qe1remBERTControl OBJECT-TYPE
SYNTAX INTEGER {
na(0), --//RIKER2021 SilverCreek
bert-off(1),
bert-full(2),
bert-dte1(3),
bert-dte2(4),
bert-inject-error(5),
bert-reset(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"remBert Control"
::= { qe1LineDiagControlEntry 11 }
qe1remBERTStatus OBJECT-TYPE
SYNTAX INTEGER {
na(0), --//RIKER2021 SilverCreek
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Status"
::= { qe1LineDiagControlEntry 13 }
qe1remBERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Counter"
::= { qe1LineDiagControlEntry 14 }
qe1remBERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Elapsed Time"
::= { qe1LineDiagControlEntry 15 }
qe1remBERTErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Error Seconds"
::= { qe1LineDiagControlEntry 16 }
qe1remBERTPatternUnsyncSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Pattern Unsync Seconds"
::= { qe1LineDiagControlEntry 17 }
qe1PatternSend OBJECT-TYPE
SYNTAX INTEGER {
pat1kHzMilliwattOff(1),
pat1kHzMilliwattUlaw(2),
pat1kHzMilliwattAlaw(3),
oldVersionNotSupport(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qe1 Pattern"
::= { qe1LineDiagControlEntry 18 }
qe1PatternMap OBJECT-TYPE
SYNTAX DisplayString (SIZE (31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAP has 31 chars, i=idle, 1=map. Ex:
1111iiiiiiiiiiiiiiiiiiiiiiiiiii => send PATTERN in TS1~4"
::= { qe1LineDiagControlEntry 19 }
--
-- Port Status Table
--
qe1PortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Qe1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status table."
::= { qe1-card 23 }
qe1PortStatusEntry OBJECT-TYPE
SYNTAX Qe1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status entry"
INDEX { qe1PSSlotIndex , qe1PSPortIndex }
::= { qe1PortStatusTable 1 }
Qe1PortStatusEntry ::= SEQUENCE {
qe1PSSlotIndex LargeSlotIndex,
qe1PSPortIndex FourPortID,
qe1PortLOS INTEGER,
qe1PortLOF INTEGER,
qe1PortRcvAIS INTEGER,
qe1PortRcvRAI INTEGER,
qe1PortXmtAIS INTEGER,
qe1PortXmtRAI INTEGER,
qe1PortBPVcount Integer32,
qe1PortEScount Integer32
}
qe1PSSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"slot index"
::= { qe1PortStatusEntry 1 }
qe1PSPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port index"
::= { qe1PortStatusEntry 2 }
qe1PortLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOS State"
::= { qe1PortStatusEntry 3 }
qe1PortLOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
loFAS(2),
loCAS(3),
loFASandCAS(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOF State"
::= { qe1PortStatusEntry 4 }
qe1PortRcvAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received AIS State"
::= { qe1PortStatusEntry 5 }
qe1PortRcvRAI OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received RAI State"
::= { qe1PortStatusEntry 6 }
qe1PortXmtAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit AIS State"
::= { qe1PortStatusEntry 7 }
qe1PortXmtRAI OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit RAI State"
::= { qe1PortStatusEntry 8 }
qe1PortBPVcount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BPV count"
::= { qe1PortStatusEntry 9 }
qe1PortEScount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES count"
::= { qe1PortStatusEntry 10 }
--
-- Command Control Table
--
qe1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qe1-card 20 }
qe1CommandControlEntry OBJECT-TYPE
SYNTAX QE1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qe1Index , qe1PortIndex }
::= { qe1CommandControlTable 1 }
QE1CommandControlEntry ::= SEQUENCE {
qe1AlarmQueueReset INTEGER,
qe1UserPerfReset INTEGER,
qe1AlarmHistoryReset INTEGER,
qe1PortReset INTEGER,
qe1PortLoadDefault INTEGER
}
qe1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { qe1CommandControlEntry 2 }
qe1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { qe1CommandControlEntry 3 }
qe1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { qe1CommandControlEntry 4 }
qe1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset QE1 Port"
::= { qe1CommandControlEntry 5 }
qe1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QE1 Port"
::= { qe1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
qe1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { qe1-card 21 }
qe1SystemInformationEntry OBJECT-TYPE
SYNTAX QE1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { qe1Index }
::= { qe1SystemInformationTable 1 }
QE1SystemInformationEntry ::= SEQUENCE {
qe1PROMVersion DisplayString,
qe1HardwareVersion DisplayString
}
qe1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" qe1 PROM Version"
::= { qe1SystemInformationEntry 2 }
qe1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" qe1 Hardware Version"
::= { qe1SystemInformationEntry 3 }
--
-- QE1 Customer Information Table
--
qe1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { qe1-card 99 }
qe1CustomerInfoEntry OBJECT-TYPE
SYNTAX QE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { qe1CISlotIndex , qe1CIPortIndex }
::= { qe1CustomerInfoTable 1 }
QE1CustomerInfoEntry ::= SEQUENCE {
qe1CISlotIndex LargeSlotIndex,
qe1CIPortIndex FourPortID,
qe1CICustomerInfo DisplayString (SIZE(0..64))
}
qe1CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qe1CustomerInfoEntry 1 }
qe1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { qe1CustomerInfoEntry 2 }
qe1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { qe1CustomerInfoEntry 3 }
--
-- Remote Link Identification Table
--
qe1RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF QE1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification Table"
::= { qe1-card 22 }
qe1RemoteLinkIDEntry OBJECT-TYPE
SYNTAX QE1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification entry"
INDEX { qe1Index ,
qe1PortIndex }
::= { qe1RemoteLinkIDTable 1 }
QE1RemoteLinkIDEntry ::= SEQUENCE {
qe1RemoteLinkIDType INTEGER,
qe1RemoteLinkIDRack INTEGER,
qe1RemoteLinkIDSlotNumber INTEGER,
qe1RemoteLinkIDPort INTEGER,
qe1RemoteLinkIDSerialNumber INTEGER,
qe1RemoteLinkIDBackupSlotNUM INTEGER,
qe1RemoteLinkIDBackupPort INTEGER
}
qe1RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of remote site."
::= { qe1RemoteLinkIDEntry 3 }
qe1RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { qe1RemoteLinkIDEntry 4 }
qe1RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { qe1RemoteLinkIDEntry 5 }
qe1RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { qe1RemoteLinkIDEntry 6 }
qe1RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { qe1RemoteLinkIDEntry 7 }
qe1RemoteLinkIDBackupSlotNUM OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Slot Number"
::= { qe1RemoteLinkIDEntry 8 }
qe1RemoteLinkIDBackupPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Port"
::= { qe1RemoteLinkIDEntry 9 }
--======================================================================--
remote-e1500-2s OBJECT IDENTIFIER ::= { qe1-card 31 }
--======================================================================--
--
-- Far End Current Performance Table
--
re1CurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 current performance table."
::= { remote-e1500-2s 1 }
re1CurrentPerfEntry OBJECT-TYPE
SYNTAX RE1CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the remote E1 current performance table."
INDEX { re1SlotIndex , re1PortIndex }
::= { re1CurrentPerfTable 1 }
RE1CurrentPerfEntry ::= SEQUENCE {
re1SlotIndex LargeSlotIndex,
re1PortIndex FourPortID,
re1CurrentES INTEGER,
re1CurrentSES INTEGER,
re1CurrentBES INTEGER,
re1CurrentUAS INTEGER,
re1CurrentCSS INTEGER,
re1CurrentDM INTEGER
}
re1SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { re1CurrentPerfEntry 1 }
re1PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { re1CurrentPerfEntry 2 }
re1CurrentES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { re1CurrentPerfEntry 3 }
re1CurrentSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { re1CurrentPerfEntry 4 }
re1CurrentBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { re1CurrentPerfEntry 5 }
re1CurrentUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { re1CurrentPerfEntry 6 }
re1CurrentCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { re1CurrentPerfEntry 7 }
re1CurrentDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { re1CurrentPerfEntry 8 }
--
-- Far End Interval Performance Table
--
re1IntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1IntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 interval performance table."
::= { remote-e1500-2s 2 }
re1IntervalPerfEntry OBJECT-TYPE
SYNTAX RE1IntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the remote E1 interval performance table."
INDEX { re1SlotIndex , re1PortIndex , re1IntervalIndex }
::= { re1IntervalPerfTable 1 }
RE1IntervalPerfEntry ::= SEQUENCE {
re1IntervalIndex INTEGER (1..96),
re1IntervalES INTEGER,
re1IntervalSES INTEGER,
re1IntervalBES INTEGER,
re1IntervalUAS INTEGER,
re1IntervalCSS INTEGER,
re1IntervalDM INTEGER
}
re1IntervalIndex OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FarInterval Index "
::= { re1IntervalPerfEntry 3 }
re1IntervalES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { re1IntervalPerfEntry 4 }
re1IntervalSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { re1IntervalPerfEntry 5 }
re1IntervalBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { re1IntervalPerfEntry 6 }
re1IntervalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { re1IntervalPerfEntry 7 }
re1IntervalCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { re1IntervalPerfEntry 8 }
re1IntervalDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { re1IntervalPerfEntry 9 }
--
-- Far End Total Performance
--
re1TotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 Total performance table."
::= { remote-e1500-2s 3 }
re1TotalPerfEntry OBJECT-TYPE
SYNTAX RE1TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the remote E1 total performance table."
INDEX { re1SlotIndex , re1PortIndex }
::= { re1TotalPerfTable 1 }
RE1TotalPerfEntry ::= SEQUENCE {
re1TotalES INTEGER,
re1TotalSES INTEGER,
re1TotalBES INTEGER,
re1TotalUAS INTEGER,
re1TotalCSS INTEGER,
re1TotalDM INTEGER
}
re1TotalES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { re1TotalPerfEntry 3 }
re1TotalSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { re1TotalPerfEntry 4 }
re1TotalBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { re1TotalPerfEntry 5 }
re1TotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { re1TotalPerfEntry 6 }
re1TotalCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { re1TotalPerfEntry 7 }
re1TotalDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { re1TotalPerfEntry 8 }
--
-- Far End Seven Day Performance Table
--
re1SevenDayPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1SevenDayPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 7 days performance table."
::= { remote-e1500-2s 4 }
re1SevenDayPerfEntry OBJECT-TYPE
SYNTAX RE1SevenDayPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the remote E1 7 days performance table."
INDEX { re1SlotIndex , re1PortIndex , re1SevenDayIndex }
::= { re1SevenDayPerfTable 1 }
RE1SevenDayPerfEntry ::= SEQUENCE {
re1SevenDayIndex INTEGER (1..7),
re1SevenDayDate DisplayString (SIZE (0..255) ),
re1SevenDayES INTEGER,
re1SevenDaySES INTEGER,
re1SevenDayBES INTEGER,
re1SevenDayUAS INTEGER,
re1SevenDayCSS INTEGER,
re1SevenDayDM INTEGER
}
re1SevenDayIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU SevenDay Index "
::= { re1SevenDayPerfEntry 3 }
re1SevenDayDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU SevenDay String "
::= { re1SevenDayPerfEntry 4 }
re1SevenDayES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { re1SevenDayPerfEntry 5 }
re1SevenDaySES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { re1SevenDayPerfEntry 6 }
re1SevenDayBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { re1SevenDayPerfEntry 7 }
re1SevenDayUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { re1SevenDayPerfEntry 8 }
re1SevenDayCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { re1SevenDayPerfEntry 9 }
re1SevenDayDM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { re1SevenDayPerfEntry 10 }
--
-- Remote Line Control
--
re1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote line control table."
::= { remote-e1500-2s 5 }
re1LineControlEntry OBJECT-TYPE
SYNTAX RE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the remote E1 line control table."
INDEX { re1SlotIndex , re1PortIndex }
::= { re1LineControlTable 1 }
RE1LineControlEntry ::= SEQUENCE {
re1ActiveMAP INTEGER,
re1MAP1SwitchTime DisplayString,
re1MAP2SwitchTime DisplayString,
re1LineCRCFrameFormat INTEGER,
re1LineCoding INTEGER,
re1RaiAlarmTx INTEGER,
re1FDL INTEGER,
re1IdleCode INTEGER,
re1LineFrame INTEGER,
re1LineEbit INTEGER,
re1LineCAS INTEGER
}
re1ActiveMAP OBJECT-TYPE
SYNTAX INTEGER {
map1(1),
map2(2),
swmap(3),
swmap2(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Active MAP1 or MAP2 or SWMAP1"
::= { re1LineControlEntry 3 }
re1MAP1SwitchTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map1 Switch Time.Format= hh:mm"
::= { re1LineControlEntry 4 }
re1MAP2SwitchTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map2 Switch Time.Format= hh:mm"
::= { re1LineControlEntry 5 }
re1LineCRCFrameFormat OBJECT-TYPE
SYNTAX INTEGER {
crc-on(1),
crc-off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line CRC Frame Format"
::= { re1LineControlEntry 6 }
re1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
hdb3(1),
ami(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { re1LineControlEntry 7 }
re1RaiAlarmTx OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Remote Alarm Indication Tx ON/OFF"
::= { re1LineControlEntry 8 }
re1FDL OBJECT-TYPE
SYNTAX INTEGER {
fdl(1),
off(2),
hdlc(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line FDL ON/OFF"
::= { re1LineControlEntry 9 }
re1IdleCode OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { re1LineControlEntry 10 }
re1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Frame Type "
::= { re1LineControlEntry 11 }
re1LineEbit OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line E-bit option "
::= { re1LineControlEntry 12 }
re1LineCAS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line CAS Type "
::= { re1LineControlEntry 13 }
--
-- Remote Channel Map
--
re1ChannelMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote channel map table"
::= { remote-e1500-2s 6 }
re1ChannelMapEntry OBJECT-TYPE
SYNTAX RE1ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex , re1MapIndex , re1ChannelIndex }
::= { re1ChannelMapTable 1 }
RE1ChannelMapEntry ::= SEQUENCE {
re1MapIndex INTEGER,
re1ChannelIndex INTEGER (1..32),
re1MapTo INTEGER
}
re1MapIndex OBJECT-TYPE
SYNTAX INTEGER {
map1(1),
map2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CSU Map Index "
::= { re1ChannelMapEntry 3 }
re1ChannelIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Index "
::= { re1ChannelMapEntry 4 }
re1MapTo OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
dte1(2),
dte2(3),
dte3(4),
dte4(5),
dropandinsert(6),
s(7),
inband(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Channel map to"
::= { re1ChannelMapEntry 5 }
--
-- Remote DTE Control
--
re1DTEControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1DTEControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 - DTE control table"
::= { remote-e1500-2s 7 }
re1DTEControlEntry OBJECT-TYPE
SYNTAX RE1DTEControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex , re1DTEIndex }
::= { re1DTEControlTable 1 }
RE1DTEControlEntry ::= SEQUENCE {
re1DTEIndex INTEGER,
re1DTERate INTEGER,
re1DTEClockPolarity INTEGER,
re1DTEDataPolarity INTEGER,
re1DTEInterfaceType INTEGER,
re1DTERTSMode INTEGER,
re1DTETerminalTimingMode INTEGER,
re1DTEV54 INTEGER,
re1DTEV54RL INTEGER,
re1DTEV54LL INTEGER
}
re1DTEIndex OBJECT-TYPE
SYNTAX INTEGER {
dte1(1),
dte2(2),
dte3(3),
dte4(4),
not-exist(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Index (1..4)"
::= { re1DTEControlEntry 3 }
re1DTERate OBJECT-TYPE
SYNTAX INTEGER {
rate-64k(1),
rate-56k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Rate "
::= { re1DTEControlEntry 4 }
re1DTEClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Clock Polarity "
::= { re1DTEControlEntry 5 }
re1DTEDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Data Polarity "
::= { re1DTEControlEntry 6 }
re1DTEInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
eia530-rs449(1),
v35(2),
x21(3),
rs232(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Interface Type "
::= { re1DTEControlEntry 7 }
re1DTERTSMode OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE RTS Permanent "
::= { re1DTEControlEntry 8 }
re1DTETerminalTimingMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Terminal Timing Mode "
::= { re1DTEControlEntry 9 }
re1DTEV54 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
ansi(2),
itu(3),
na(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" V.54 Setup "
::= { re1DTEControlEntry 10 }
re1DTEV54RL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Remote Loopback Setup "
::= { re1DTEControlEntry 11 }
re1DTEV54LL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Local Loopback Setup "
::= { re1DTEControlEntry 12 }
--
-- Remote System Control
--
re1SystemControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1SystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 - System control table"
::= { remote-e1500-2s 8 }
re1SystemControlEntry OBJECT-TYPE
SYNTAX RE1SystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex }
::= { re1SystemControlTable 1 }
RE1SystemControlEntry ::= SEQUENCE {
re1MasterClock INTEGER,
re1SecondClock INTEGER,
re1ClockIndicator INTEGER,
re1DeviceName DisplayString,
re1PortConfiguration DisplayString,
re1SerialNumber INTEGER,
re1MainboardVersion INTEGER,
re1FirmwareVersion DisplayString
}
re1MasterClock OBJECT-TYPE
SYNTAX INTEGER {
line(1),
internal(2),
dropinsert(3),
dte1(4),
dte2(5),
dte3(6),
dte4(7),
external56k(8),
external64k(9),
external112k(10),
external128k(11),
external168k(12),
external192k(13),
external224k(14),
external256k(15),
external280k(16),
external320k(17),
external336k(18),
external384k(19),
external392k(20),
external448k(21),
external504k(22),
external512k(23),
external560k(24),
external576k(25),
external616k(26),
external640k(27),
external672k(28),
external704k(29),
external728k(30),
external768k(31),
external784k(32),
external832k(33),
external840k(34),
external896k(35),
external952k(36),
external960k(37),
external1008k(38),
external1024k(39),
external1064k(40),
external1088k(41),
external1120k(42),
external1152k(43),
external1176k(44),
external1216k(45),
external1232k(46),
external1280k(47),
external1288k(48),
external1344k(49),
external1400k(50),
external1408k(51),
external1456k(52),
external1472k(53),
external1512k(54),
external1536k(55),
external1568k(56),
external1600k(57),
external1624k(58),
external1664k(59),
external1680k(60),
external1728k(61),
external1736k(62),
external1792k(63),
external1848k(64),
external1856k(65),
external1904k(66),
external1920k(67),
external1960k(68),
external1984k(69),
external2016k(70),
external2048k(71),
external8192k(72)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CSU Master Clock Setting"
::= { re1SystemControlEntry 3 }
re1SecondClock OBJECT-TYPE
SYNTAX INTEGER {
line(1),
internal(2),
dropinsert(3),
dte1(4),
dte2(5),
dte3(6),
dte4(7),
external56k(8),
external64k(9),
external112k(10),
external128k(11),
external168k(12),
external192k(13),
external224k(14),
external256k(15),
external280k(16),
external320k(17),
external336k(18),
external384k(19),
external392k(20),
external448k(21),
external504k(22),
external512k(23),
external560k(24),
external576k(25),
external616k(26),
external640k(27),
external672k(28),
external704k(29),
external728k(30),
external768k(31),
external784k(32),
external832k(33),
external840k(34),
external896k(35),
external952k(36),
external960k(37),
external1008k(38),
external1024k(39),
external1064k(40),
external1088k(41),
external1120k(42),
external1152k(43),
external1176k(44),
external1216k(45),
external1232k(46),
external1280k(47),
external1288k(48),
external1344k(49),
external1400k(50),
external1408k(51),
external1456k(52),
external1472k(53),
external1512k(54),
external1536k(55),
external1568k(56),
external1600k(57),
external1624k(58),
external1664k(59),
external1680k(60),
external1728k(61),
external1736k(62),
external1792k(63),
external1848k(64),
external1856k(65),
external1904k(66),
external1920k(67),
external1960k(68),
external1984k(69),
external2016k(70),
external2048k(71),
external8192k(72)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CSU Remote Second Clock Setting"
::= { re1SystemControlEntry 4 }
re1ClockIndicator OBJECT-TYPE
SYNTAX INTEGER {
master(1),
second(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Remote Clock Indicator"
::= { re1SystemControlEntry 5 }
re1DeviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CSU Device Name "
::= { re1SystemControlEntry 6 }
re1PortConfiguration OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Port Configuration"
::= { re1SystemControlEntry 7 }
re1SerialNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Serial Number "
::= { re1SystemControlEntry 8 }
re1MainboardVersion OBJECT-TYPE
SYNTAX INTEGER {
a(65),
b(66),
c(67),
d(68),
e(69),
f(70),
g(71),
h(73),
i(74),
j(75)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Mainboard Version"
::= { re1SystemControlEntry 9 }
re1FirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Firmware Version"
::= { re1SystemControlEntry 10 }
--
-- Remote Alarm Control
--
re1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote alarm control table"
::= { remote-e1500-2s 9 }
re1AlarmControlEntry OBJECT-TYPE
SYNTAX RE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex , re1AlarmControlIndex }
::= { re1AlarmControlTable 1 }
RE1AlarmControlEntry ::= SEQUENCE {
re1AlarmControlIndex INTEGER,
re1Alarm-dialout INTEGER
}
re1AlarmControlIndex OBJECT-TYPE
SYNTAX INTEGER {
alarm-master-clcok-loss(1),
alarm-rai-line(2),
alarm-ais-line(3),
alarm-los-line(4),
alarm-lof-line(5),
alarm-bpv-line(6),
alarm-es-line(7),
alarm-uas-line(8),
alarm-css-line(9),
alarm-dte1-dte(10),
alarm-dte2-dte(11),
alarm-lan-alm-router1(12),
alarm-lan-alm-router2(13),
alarm-yel-DI(14),
alarm-ais-DI(15),
alarm-los-DI(16),
alarm-lof-DI(17),
alarm-bpv-DI(18),
alarm-es-DI(19),
alarm-uas-DI(20),
alarm-rai-dte1-e1(21),
alarm-ais-dte1-e1(22),
alarm-los-dte1-e1(23),
alarm-lof-dte1-e1(24),
alarm-bpv-dte1-e1(25),
alarm-es-dte1-e1(26),
alarm-uas-dte1-e1(27),
alarm-css-dte1-e1(28),
alarm-rai-dte2-e1(29),
alarm-ais-dte2-e1(30),
alarm-los-dte2-e1(31),
alarm-lof-dte2-e1(32),
alarm-bpv-dte2-e1(33),
alarm-es-dte2-e1(34),
alarm-uas-dte2-e1(35),
alarm-css-dte2-e1(36)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Alarm Control Index "
::= { re1AlarmControlEntry 3 }
re1Alarm-dialout OBJECT-TYPE
SYNTAX INTEGER {
disable(5),
enable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Remote Alarm Control "
::= { re1AlarmControlEntry 4 }
--
-- Remote Threshold Control
--
re1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote alarm threshold control table"
::= { remote-e1500-2s 10 }
re1ThresholdControlEntry OBJECT-TYPE
SYNTAX RE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex }
::= { re1ThresholdControlTable 1 }
RE1ThresholdControlEntry ::= SEQUENCE {
re1ThresholdBPV-Line INTEGER,
re1ThresholdES-Line INTEGER,
re1ThresholdUAS-Line INTEGER,
re1ThresholdCSS-Line INTEGER,
re1ThresholdBPV-DTE1-E1 INTEGER,
re1ThresholdES-DTE1-E1 INTEGER,
re1ThresholdUAS-DTE1-E1 INTEGER,
re1ThresholdCSS-DTE1-E1 INTEGER,
re1ThresholdBPV-DTE2-E1 INTEGER,
re1ThresholdES-DTE2-E1 INTEGER,
re1ThresholdUAS-DTE2-E1 INTEGER,
re1ThresholdCSS-DTE2-E1 INTEGER,
re1ThresholdBPV-Drop-Insert INTEGER,
re1ThresholdES-Drop-Insert INTEGER,
re1ThresholdUAS-Drop-Insert INTEGER
}
re1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line "
::= { re1ThresholdControlEntry 3 }
re1ThresholdES-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ES-Line "
::= { re1ThresholdControlEntry 4 }
re1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { re1ThresholdControlEntry 5 }
re1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CSS-Line "
::= { re1ThresholdControlEntry 6 }
re1ThresholdBPV-DTE1-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-EQU1 "
::= { re1ThresholdControlEntry 7 }
re1ThresholdES-DTE1-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ES-EQU1 "
::= { re1ThresholdControlEntry 8 }
re1ThresholdUAS-DTE1-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-EQU1 "
::= { re1ThresholdControlEntry 9 }
re1ThresholdCSS-DTE1-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-EQU1 "
::= { re1ThresholdControlEntry 10 }
re1ThresholdBPV-DTE2-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-EQU2 "
::= { re1ThresholdControlEntry 11 }
re1ThresholdES-DTE2-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ES-EQU2 "
::= { re1ThresholdControlEntry 12 }
re1ThresholdUAS-DTE2-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-EQU2 "
::= { re1ThresholdControlEntry 13 }
re1ThresholdCSS-DTE2-E1 OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-EQU2 "
::= { re1ThresholdControlEntry 14 }
re1ThresholdBPV-Drop-Insert OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of D&I "
::= { re1ThresholdControlEntry 15 }
re1ThresholdES-Drop-Insert OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of D&I "
::= { re1ThresholdControlEntry 16 }
re1ThresholdUAS-Drop-Insert OBJECT-TYPE
SYNTAX INTEGER {
na(65535)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of D&I "
::= { re1ThresholdControlEntry 17 }
--
-- REMOTE Model Type Table
--
re1ModelTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1ModelTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote model type table"
::= { remote-e1500-2s 11 }
re1ModelTypeEntry OBJECT-TYPE
SYNTAX RE1ModelTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex }
::= { re1ModelTypeTable 1 }
RE1ModelTypeEntry ::= SEQUENCE {
re1ModelType INTEGER
}
re1ModelType OBJECT-TYPE
SYNTAX INTEGER {
loop-E-1201-1(1),
loop-E-1201-2(2),
loop-E-1201-3(3),
loop-E-1201-4(4),
loop-E-1202-1(5),
loop-E-1202-2(6),
loop-E-1202-3(7),
loop-E-1202-4(8),
loop-E-1300(9),
loop-E-1500(10),
loop-E-1700(11),
loop-E-1500-IR(16),
loop-E-1500-2S(20),
loop-T-2500-2S(21),
fdl-off(253),
unsync(254),
unknow(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSU Remote Mode Type"
::= { re1ModelTypeEntry 1 }
--
-- Remote Alarm History Performance Table
--
re1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote alarm status table"
::= { remote-e1500-2s 12 }
re1AlarmHistoryEntry OBJECT-TYPE
SYNTAX RE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex , re1AlarmHistoryIndex }
::= { re1AlarmHistoryTable 1 }
RE1AlarmHistoryEntry ::= SEQUENCE {
re1AlarmHistoryIndex INTEGER,
-- re1StartTime
-- DisplayString (SIZE (0..255) ),
re1Threshold INTEGER,
re1CurrentState INTEGER,
re1CurrentCount INTEGER,
re1Alarm INTEGER,
re1Trap INTEGER,
re1Bell INTEGER
}
re1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
master-clcok(1),
rai-line(2),
ais-line(3),
los-line(4),
lof-line(5),
bpv-line(6),
es-line(7),
uas-line(8),
css-line(9),
dte1-dte(10),
dte2-dte(11),
lan-alm-router1(12),
lan-alm-router2(13),
yel-DI(14),
ais-DI(15),
los-DI(16),
lof-DI(17),
bpv-DI(18),
es-DI(19),
uas-DI(20),
rai-dte1-e1(21),
ais-dte1-e1(22),
los-dte1-e1(23),
lof-dte1-e1(24),
bpv-dte1-e1(25),
es-dte1-e1(26),
uas-dte1-e1(27),
css-dte1-e1(28),
rai-dte2-e1(29),
ais-dte2-e1(30),
los-dte2-e1(31),
lof-dte2-e1(32),
bpv-dte2-e1(33),
es-dte2-e1(34),
uas-dte2-e1(35),
css-dte2-e1(36)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { re1AlarmHistoryEntry 3 }
-- re1StartTime OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255) )
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Alarm History Start Time"
-- ::= { re1AlarmHistoryEntry 4 }
re1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { re1AlarmHistoryEntry 5 }
re1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { re1AlarmHistoryEntry 6 }
re1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { re1AlarmHistoryEntry 7 }
re1Alarm OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { re1AlarmHistoryEntry 8 }
re1Trap OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Trap State "
::= { re1AlarmHistoryEntry 9 }
re1Bell OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Bell State"
::= { re1AlarmHistoryEntry 10 }
--
-- Remote E1 Card Control Table
--
re1E1CardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1E1CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote E1 card control table."
::= { remote-e1500-2s 13 }
re1E1CardControlEntry OBJECT-TYPE
SYNTAX RE1E1CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { re1SlotIndex , re1PortIndex , re1E1CardIndex }
::= { re1E1CardControlTable 1 }
RE1E1CardControlEntry ::= SEQUENCE {
re1E1CardIndex INTEGER,
re1E1LineFrame INTEGER,
re1E1LineCoding INTEGER,
--re1E1FDL
--INTEGER,
--re1E1FDLSabit
--INTEGER,
re1E1RAI INTEGER,
re1E1CRC INTEGER,
re1E1IdleCode INTEGER,
re1E1Ebit INTEGER,
re1E1CASMode INTEGER
}
re1E1CardIndex OBJECT-TYPE
SYNTAX INTEGER {
dte1(1),
dte2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte1 & dte2, total 2 ports."
::= { re1E1CardControlEntry 3 }
re1E1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { re1E1CardControlEntry 4 }
re1E1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
hdb3(1),
ami(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { re1E1CardControlEntry 5 }
-- re1E1FDL OBJECT-TYPE
-- SYNTAX INTEGER {
-- on(1),
-- off(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "E1 Facility Data Link ON/OFF"
-- ::= { re1E1CardControlEntry 6 }
--re1E1FDLSabit OBJECT-TYPE
-- SYNTAX INTEGER {
-- sa4(1),
-- sa5(2),
-- sa6(3),
-- sa7(4),
-- sa8(5),
-- sa4-sa5(6)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "E1 Facility Data Link use Sax bit"
-- ::= { re1E1CardControlEntry 7 }
re1E1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { re1E1CardControlEntry 8 }
re1E1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Cycle Redundancy Check ON/OFF"
::= { re1E1CardControlEntry 9 }
re1E1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { re1E1CardControlEntry 10 }
re1E1Ebit OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-bit "
::= { re1E1CardControlEntry 11 }
re1E1CASMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { re1E1CardControlEntry 12 }
--
-- Remote COD Control
--
re1CODControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1CODEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote co-direction control table"
::= { remote-e1500-2s 14 }
re1CODEntry OBJECT-TYPE
SYNTAX RE1CODEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex , re1CODIndex }
::= { re1CODControlTable 1 }
RE1CODEntry ::= SEQUENCE {
re1CODIndex INTEGER,
re1CODRate INTEGER,
re1CODInterfaceType INTEGER
}
re1CODIndex OBJECT-TYPE
SYNTAX INTEGER {
dte1(1),
dte2(2),
dte3(3),
dte4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Index (1..4)"
::= { re1CODEntry 3 }
re1CODRate OBJECT-TYPE
SYNTAX INTEGER {
rate-64k(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Rate "
::= { re1CODEntry 4 }
re1CODInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
g703(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interface Type "
::= { re1CODEntry 5 }
--
-- REMOTE D&I Control MIBs
--
re1DropInsertTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1DropInsertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote drop and insert table"
::= { remote-e1500-2s 15 }
re1DropInsertEntry OBJECT-TYPE
SYNTAX RE1DropInsertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex }
::= { re1DropInsertTable 1 }
RE1DropInsertEntry ::= SEQUENCE {
re1DICRCFrameFormat INTEGER,
re1DILineCode INTEGER
}
re1DICRCFrameFormat OBJECT-TYPE
SYNTAX INTEGER {
crc-on(1),
crc-off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" D&I CRC Frame Format "
::= { re1DropInsertEntry 3 }
re1DILineCode OBJECT-TYPE
SYNTAX INTEGER {
hdb3(1),
ami(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" D&I Line Code "
::= { re1DropInsertEntry 4 }
--
-- REMOTE Channel Map Setup
--
re1MapSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF RE1MapSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote channel map setup table"
::= { remote-e1500-2s 16 }
re1MapSetupEntry OBJECT-TYPE
SYNTAX RE1MapSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { re1SlotIndex , re1PortIndex }
::= { re1MapSetupTable 1 }
RE1MapSetupEntry ::= SEQUENCE {
re1Map1 DisplayString (SIZE(31)),
re1Map2 DisplayString (SIZE(31))
}
re1Map1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mpa 1"
::= { re1MapSetupEntry 3 }
re1Map2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mpa 2"
::= { re1MapSetupEntry 4 }
qe1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of QE1"
::= { qe1-card 100 }
--======================================================================--
--======================================================================--
-- quad-t1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
qt1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { qt1-card 1 }
qt1LineControlEntry OBJECT-TYPE
SYNTAX QT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1LineControlTable 1 }
QT1LineControlEntry ::= SEQUENCE {
qt1Index LargeSlotIndex,
qt1PortIndex FourPortID,
qt1LineFrame INTEGER,
qt1LineCoding INTEGER,
qt1Interface INTEGER,
qt1LineBuildOut INTEGER,
qt1Equalizer INTEGER,
qt1AIS INTEGER,
qt1YEL INTEGER,
qt1Inband INTEGER,
qt1IdleCode INTEGER,
qt1CASMode INTEGER,
qt1SignallingMode INTEGER,
qt1CGA INTEGER,
qt1OutOfService INTEGER,
qt1FDL INTEGER,
qt1Protect INTEGER,
qt1Master INTEGER,
qt1PortEnable INTEGER
}
qt1Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qt1LineControlEntry 1 }
qt1PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { qt1LineControlEntry 2 }
qt1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esf-t1-403(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { qt1LineControlEntry 3 }
qt1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { qt1LineControlEntry 4 }
qt1Interface OBJECT-TYPE
SYNTAX INTEGER {
long-haul(1),
short-haul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that QT1 line use Long/Short haul."
::= { qt1LineControlEntry 5 }
qt1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo-0-0dB(1),
lbo-7-5dB(2),
lbo-15dB(3)
-- lbo-0.0dB(1),
-- lbo-7.5dB(2),
-- lbo-15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 line build out."
::= { qt1LineControlEntry 6 }
qt1Equalizer OBJECT-TYPE
SYNTAX INTEGER {
equ-0-110Ft(1),
equ-110-220ft(2),
equ-220-330ft(3),
equ-330-440ft(4),
equ-440-550ft(5),
equ-550-660ft(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 line equalizer."
::= { qt1LineControlEntry 7 }
qt1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 line Alarm Indication Signal."
::= { qt1LineControlEntry 8 }
qt1YEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { qt1LineControlEntry 9 }
qt1Inband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 line inband ON/OFF"
::= { qt1LineControlEntry 10 }
qt1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { qt1LineControlEntry 11 }
qt1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { qt1LineControlEntry 12 }
qt1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS"
::= { qt1LineControlEntry 13 }
qt1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { qt1LineControlEntry 14 }
qt1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { qt1LineControlEntry 15 }
qt1FDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 Facility Data Link ON/OFF"
::= { qt1LineControlEntry 16 }
qt1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { qt1LineControlEntry 17 }
qt1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { qt1LineControlEntry 18 }
qt1PortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QT1 port enable/disable"
::= { qt1LineControlEntry 19 }
--
-- User Current Performance Table
--
qt1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { qt1-card 2 }
qt1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX QT1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { qt1Index , qt1PortIndex }
::= { qt1UserCurrentPerfTable 1 }
QT1UserCurrentPerfEntry ::= SEQUENCE {
qt1UserCurrentPerfES INTEGER,
qt1UserCurrentPerfSES INTEGER,
qt1UserCurrentPerfBES INTEGER,
qt1UserCurrentPerfUAS INTEGER,
qt1UserCurrentPerfCSS INTEGER,
qt1UserCurrentPerfBPV INTEGER,
qt1UserCurrentPerfLOFC INTEGER,
qt1UserCurr15MinTimeElapsed INTEGER,
qt1UserValid15MinInterval INTEGER
}
qt1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1UserCurrentPerfEntry 2 }
qt1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1UserCurrentPerfEntry 3 }
qt1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1UserCurrentPerfEntry 4 }
qt1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1UserCurrentPerfEntry 5 }
qt1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { qt1UserCurrentPerfEntry 6 }
qt1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1UserCurrentPerfEntry 7 }
qt1UserCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1UserCurrentPerfEntry 8 }
qt1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { qt1UserCurrentPerfEntry 11 }
qt1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { qt1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
qt1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { qt1-card 3 }
qt1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX QT1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { qt1Index , qt1PortIndex ,
qt1UserIntervalPerfNumber }
::= { qt1UserIntervalPerfTable 1 }
QT1UserIntervalPerfEntry ::= SEQUENCE {
qt1UserIntervalPerfNumber INTEGER (1..96),
qt1UserIntervalPerfES INTEGER,
qt1UserIntervalPerfSES INTEGER,
qt1UserIntervalPerfBES INTEGER,
qt1UserIntervalPerfUAS INTEGER,
qt1UserIntervalPerfCSS INTEGER,
qt1UserIntervalPerfBPV INTEGER,
qt1UserIntervalPerfLOFC INTEGER
}
qt1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { qt1UserIntervalPerfEntry 2 }
qt1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1UserIntervalPerfEntry 3 }
qt1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1UserIntervalPerfEntry 4 }
qt1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1UserIntervalPerfEntry 5 }
qt1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1UserIntervalPerfEntry 6 }
qt1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1UserIntervalPerfEntry 7 }
qt1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1UserIntervalPerfEntry 8 }
qt1UserIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
qt1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { qt1-card 4 }
qt1UserTotalPerfEntry OBJECT-TYPE
SYNTAX QT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { qt1Index , qt1PortIndex }
::= { qt1UserTotalPerfTable 1 }
QT1UserTotalPerfEntry ::= SEQUENCE {
qt1UserTotalPerfES INTEGER,
qt1UserTotalPerfSES INTEGER,
qt1UserTotalPerfBES INTEGER,
qt1UserTotalPerfUAS INTEGER,
qt1UserTotalPerfCSS INTEGER,
qt1UserTotalPerfBPV INTEGER,
qt1UserTotalPerfLOFC INTEGER
}
qt1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1UserTotalPerfEntry 2 }
qt1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1UserTotalPerfEntry 3 }
qt1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1UserTotalPerfEntry 4 }
qt1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1UserTotalPerfEntry 5 }
qt1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1UserTotalPerfEntry 6 }
qt1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1UserTotalPerfEntry 7 }
qt1UserTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
qt1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { qt1-card 22 }
qt1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX QT1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance entry"
INDEX { qt1Index , qt1PortIndex ,
qt1UserDaysIndex }
::= { qt1UserSevenDaysPerfTable 1 }
QT1UserSevenDaysPerfEntry ::= SEQUENCE {
qt1UserDaysIndex INTEGER (1..7),
qt1UserDateStrIndex DisplayString (SIZE (0..255) ),
qt1UserSevenDaysPerfES INTEGER,
qt1UserSevenDaysPerfSES INTEGER,
qt1UserSevenDaysPerfBES INTEGER,
qt1UserSevenDaysPerfUAS INTEGER,
qt1UserSevenDaysPerfCSS INTEGER
-- qt1UserSevenDaysPerfLOFC INTEGER
}
qt1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { qt1UserSevenDaysPerfEntry 2 }
qt1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { qt1UserSevenDaysPerfEntry 3 }
qt1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1UserSevenDaysPerfEntry 4 }
qt1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1UserSevenDaysPerfEntry 5 }
qt1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1UserSevenDaysPerfEntry 6 }
qt1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1UserSevenDaysPerfEntry 7 }
qt1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1UserSevenDaysPerfEntry 8 }
-- qt1UserSevenDaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { qt1UserSevenDaysPerfEntry 9 }
--
-- Line Current Performance Table
--
qt1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { qt1-card 8 }
qt1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX QT1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { qt1Index , qt1PortIndex }
::= { qt1LineCurrentPerfTable 1 }
QT1LineCurrentPerfEntry ::= SEQUENCE {
qt1LineCurrentPerfES INTEGER,
qt1LineCurrentPerfSES INTEGER,
qt1LineCurrentPerfBES INTEGER,
qt1LineCurrentPerfUAS INTEGER,
qt1LineCurrentPerfCSS INTEGER,
qt1LineCurrentPerfBPV INTEGER,
qt1LineCurrentPerfLOFC INTEGER,
qt1LineCurr15MinTimeElapsed INTEGER,
qt1LineValid15MinInterval INTEGER
}
qt1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { qt1LineCurrentPerfEntry 2 }
qt1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1LineCurrentPerfEntry 3 }
qt1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1LineCurrentPerfEntry 4 }
qt1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1LineCurrentPerfEntry 5 }
qt1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1LineCurrentPerfEntry 6 }
qt1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1LineCurrentPerfEntry 7 }
qt1LineCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1LineCurrentPerfEntry 8 }
qt1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { qt1LineCurrentPerfEntry 11 }
qt1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { qt1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
qt1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { qt1-card 9 }
qt1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX QT1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { qt1Index , qt1PortIndex ,
qt1LineIntervalPerfNumber }
::= { qt1LineIntervalPerfTable 1 }
QT1LineIntervalPerfEntry ::= SEQUENCE {
qt1LineIntervalPerfNumber INTEGER (1..96),
qt1LineIntervalPerfES INTEGER,
qt1LineIntervalPerfSES INTEGER,
qt1LineIntervalPerfBES INTEGER,
qt1LineIntervalPerfUAS INTEGER,
qt1LineIntervalPerfCSS INTEGER,
qt1LineIntervalPerfBPV INTEGER,
qt1LineIntervalPerfLOFC INTEGER,
qt1LineIntvAvailable INTEGER
}
qt1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index "
::= { qt1LineIntervalPerfEntry 2 }
qt1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1LineIntervalPerfEntry 3 }
qt1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1LineIntervalPerfEntry 4 }
qt1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1LineIntervalPerfEntry 5 }
qt1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1LineIntervalPerfEntry 6 }
qt1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1LineIntervalPerfEntry 7 }
qt1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1LineIntervalPerfEntry 8 }
qt1LineIntervalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1LineIntervalPerfEntry 9 }
qt1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { qt1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
qt1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { qt1-card 10 }
qt1LineTotalPerfEntry OBJECT-TYPE
SYNTAX QT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance entry"
INDEX { qt1Index , qt1PortIndex }
::= { qt1LineTotalPerfTable 1 }
QT1LineTotalPerfEntry ::= SEQUENCE {
qt1LineTotalPerfES INTEGER,
qt1LineTotalPerfSES INTEGER,
qt1LineTotalPerfBES INTEGER,
qt1LineTotalPerfUAS INTEGER,
qt1LineTotalPerfCSS INTEGER,
qt1LineTotalPerfBPV INTEGER,
qt1LineTotalPerfLOFC INTEGER
}
qt1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1LineTotalPerfEntry 2 }
qt1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1LineTotalPerfEntry 3 }
qt1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1LineTotalPerfEntry 4 }
qt1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1LineTotalPerfEntry 5 }
qt1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1LineTotalPerfEntry 6 }
qt1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { qt1LineTotalPerfEntry 7 }
qt1LineTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { qt1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
qt1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { qt1-card 21 }
qt1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX QT1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { qt1Index , qt1PortIndex ,
qt1LineDaysIndex }
::= { qt1LineSevenDaysPerfTable 1 }
QT1LineSevenDaysPerfEntry ::= SEQUENCE {
qt1LineDaysIndex INTEGER (1..7),
qt1LineDateStrIndex DisplayString (SIZE (0..255) ),
qt1LineSevenDaysPerfES INTEGER,
qt1LineSevenDaysPerfSES INTEGER,
qt1LineSevenDaysPerfBES INTEGER,
qt1LineSevenDaysPerfUAS INTEGER,
qt1LineSevenDaysPerfCSS INTEGER
-- qt1LineSevenDaysPerfLOFC INTEGER
}
qt1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { qt1LineSevenDaysPerfEntry 2 }
qt1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { qt1LineSevenDaysPerfEntry 3 }
qt1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { qt1LineSevenDaysPerfEntry 4 }
qt1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { qt1LineSevenDaysPerfEntry 5 }
qt1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { qt1LineSevenDaysPerfEntry 6 }
qt1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { qt1LineSevenDaysPerfEntry 7 }
qt1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { qt1LineSevenDaysPerfEntry 8 }
-- qt1LineSevenDaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { qt1LineSevenDaysPerfEntry 9 }
--
-- Alarm Queue Table
--
qt1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Queue Table"
::= { qt1-card 11 }
qt1AlarmQueueEntry OBJECT-TYPE
SYNTAX QT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { qt1Index , qt1PortIndex ,
qt1AlarmQueueIndex }
::= { qt1AlarmQueueTable 1 }
QT1AlarmQueueEntry ::= SEQUENCE {
qt1AlarmQueueIndex INTEGER (1..40),
qt1AlarmQueueString DisplayString (SIZE(0..255))
}
qt1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { qt1AlarmQueueEntry 2 }
qt1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { qt1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
qt1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { qt1-card 12 }
qt1AlarmHistoryEntry OBJECT-TYPE
SYNTAX QT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { qt1Index , qt1PortIndex ,
qt1AlarmHistoryIndex }
::= { qt1AlarmHistoryTable 1 }
QT1AlarmHistoryEntry ::= SEQUENCE {
qt1AlarmHistoryIndex INTEGER,
qt1Threshold INTEGER,
qt1CurrentState INTEGER,
qt1CurrentCount INTEGER,
qt1Alarm AlarmSeverity
}
qt1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
yel-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
tpca(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { qt1AlarmHistoryEntry 2 }
qt1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { qt1AlarmHistoryEntry 3 }
qt1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { qt1AlarmHistoryEntry 4 }
qt1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { qt1AlarmHistoryEntry 5 }
qt1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { qt1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
qt1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { qt1-card 13 }
qt1LineAvailabilityEntry OBJECT-TYPE
SYNTAX QT1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1LineAvailabilityTable 1 }
QT1LineAvailabilityEntry ::= SEQUENCE {
qt1AvailableSeconds DisplayString,
qt1UnavailableSeconds DisplayString,
qt1LineAvailability DisplayString
}
qt1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { qt1LineAvailabilityEntry 2 }
qt1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { qt1LineAvailabilityEntry 3 }
qt1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { qt1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
qt1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qt1-card 14 }
qt1AlarmControlEntry OBJECT-TYPE
SYNTAX QT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1AlarmControlTable 1 }
QT1AlarmControlEntry ::= SEQUENCE {
qt1YEL-Line AlarmSeverity,
qt1AIS-Line AlarmSeverity,
qt1LOS-Line AlarmSeverity,
qt1LOF-Line AlarmSeverity,
qt1BPV-Line AlarmSeverity,
qt1ESS-Line AlarmSeverity,
qt1UAS-Line AlarmSeverity,
qt1CSS-Line AlarmSeverity,
qt1TCPA AlarmSeverity
}
qt1YEL-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-Line State"
::= { qt1AlarmControlEntry 2 }
qt1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { qt1AlarmControlEntry 3 }
qt1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { qt1AlarmControlEntry 4 }
qt1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { qt1AlarmControlEntry 5 }
qt1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { qt1AlarmControlEntry 6 }
qt1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { qt1AlarmControlEntry 7 }
qt1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { qt1AlarmControlEntry 8 }
qt1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { qt1AlarmControlEntry 9 }
-- RIKER 2013 NFS-13000027
qt1TCPA OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold Crossing Performance Alarm"
::= { qt1AlarmControlEntry 10 }
--
-- Threshold Control Table
--
qt1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qt1-card 15 }
qt1ThresholdControlEntry OBJECT-TYPE
SYNTAX QT1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1ThresholdControlTable 1 }
QT1ThresholdControlEntry ::= SEQUENCE {
qt1ThresholdBPV-Line INTEGER,
qt1ThresholdESS-Line INTEGER,
qt1ThresholdUAS-Line INTEGER,
qt1ThresholdCSS-Line INTEGER,
qt1ThresholdTCPA INTEGER
}
qt1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line: 10exp-N"
::= { qt1ThresholdControlEntry 2 }
qt1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { qt1ThresholdControlEntry 3 }
qt1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { qt1ThresholdControlEntry 4 }
qt1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { qt1ThresholdControlEntry 5 }
-- RIKER 2013 NFS-13000027
qt1ThresholdTCPA OBJECT-TYPE
SYNTAX INTEGER (1..1544)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of TCPA "
::= { qt1ThresholdControlEntry 6 }
--
-- Line Diagnostic Control Table
--
qt1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { qt1-card 16 }
qt1LineDiagControlEntry OBJECT-TYPE
SYNTAX QT1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1LineDiagControlTable 1 }
QT1LineDiagControlEntry ::= SEQUENCE {
qt1LoopbackType INTEGER,
qt1LoopbackStatus INTEGER,
qt1QRSSControl INTEGER,
qt1QRSSStatus INTEGER,
qt1QRSSElapseSeconds INTEGER,
qt1QRSSErrorSeconds INTEGER,
qt1QRSSErrorCounts INTEGER,
qt1InbandLoopbackPeriod INTEGER,
qt1PatternSend INTEGER,
qt1PatternMap DisplayString
}
qt1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-LLB-Inband-Active(5),
remote-PLB-ATT-Active(6),
remote-PLB-ANSI-Active(7),
remote-LLB-ANSI-Active(8),
remote-LLB-Inband-Deactive(9),
remote-PLB-ATT-Deactive(10),
remote-PLB-ANSI-Deactive(11),
remote-LLB-ANSI-Deactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qt1 Loopback Type"
::= { qt1LineDiagControlEntry 2 }
qt1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qt1 Loopback Status"
::= { qt1LineDiagControlEntry 3 }
qt1QRSSControl OBJECT-TYPE
SYNTAX INTEGER {
qrss-deactive(1),
qrss-active-full(2),
qrss-reset-error-count(3),
qrss-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qt1 QRSS Control"
::= { qt1LineDiagControlEntry 4 }
qt1QRSSStatus OBJECT-TYPE
SYNTAX INTEGER {
qrss-sync(1),
qrss-unsync(2),
qrss-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qt1 QRSS Status"
::= { qt1LineDiagControlEntry 5 }
qt1QRSSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qt1 QRSS Elapse Seconds"
::= { qt1LineDiagControlEntry 6 }
qt1QRSSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qt1 QRSS Error Seconds"
::= { qt1LineDiagControlEntry 7 }
qt1QRSSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"qt1 QRSS Error Counts"
::= { qt1LineDiagControlEntry 8 }
qt1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of QT1 inband local, payload, or line loopback"
::= { qt1LineDiagControlEntry 9 }
qt1PatternSend OBJECT-TYPE
SYNTAX INTEGER {
pat1kHzMilliwattOff(1),
pat1kHzMilliwattUlaw(2),
oldVersionNotSupport(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qt1 Pattern"
::= { qt1LineDiagControlEntry 18 }
qt1PatternMap OBJECT-TYPE
SYNTAX DisplayString (SIZE (24))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MAP has 24 chars, i=idle, 1=map. Ex:
1111iiiiiiiiiiiiiiiiiiiiii => send PATTERN in TS1~4"
::= { qt1LineDiagControlEntry 19 }
--
-- Port Status Table
--
qt1PortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Qt1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status table."
::= { qt1-card 23 }
qt1PortStatusEntry OBJECT-TYPE
SYNTAX Qt1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status entry"
INDEX { qt1PSSlotIndex , qt1PSPortIndex }
::= { qt1PortStatusTable 1 }
Qt1PortStatusEntry ::= SEQUENCE {
qt1PSSlotIndex LargeSlotIndex,
qt1PSPortIndex FourPortID,
qt1PortLOS INTEGER,
qt1PortLOF INTEGER,
qt1PortRcvAIS INTEGER,
qt1PortRcvYEL INTEGER,
qt1PortXmtAIS INTEGER,
qt1PortXmtYEL INTEGER,
qt1PortBPVcount Integer32,
qt1PortEScount Integer32
}
qt1PSSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"slot index"
::= { qt1PortStatusEntry 1 }
qt1PSPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port index"
::= { qt1PortStatusEntry 2 }
qt1PortLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOS State"
::= { qt1PortStatusEntry 3 }
qt1PortLOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOF State"
::= { qt1PortStatusEntry 4 }
qt1PortRcvAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received AIS State"
::= { qt1PortStatusEntry 5 }
qt1PortRcvYEL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received YEL State"
::= { qt1PortStatusEntry 6 }
qt1PortXmtAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit AIS State"
::= { qt1PortStatusEntry 7 }
qt1PortXmtYEL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit YEL State"
::= { qt1PortStatusEntry 8 }
qt1PortBPVcount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BPV count"
::= { qt1PortStatusEntry 9 }
qt1PortEScount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES count"
::= { qt1PortStatusEntry 10 }
--
-- Command Control Table
--
qt1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qt1-card 17 }
qt1CommandControlEntry OBJECT-TYPE
SYNTAX QT1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qt1Index , qt1PortIndex }
::= { qt1CommandControlTable 1 }
QT1CommandControlEntry ::= SEQUENCE {
qt1AlarmQueueReset INTEGER,
qt1UserPerfReset INTEGER,
qt1AlarmHistoryReset INTEGER,
qt1PortReset INTEGER,
qt1PortLoadDefault INTEGER
}
qt1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { qt1CommandControlEntry 2 }
qt1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { qt1CommandControlEntry 3 }
qt1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { qt1CommandControlEntry 4 }
qt1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset QT1 Port"
::= { qt1CommandControlEntry 5 }
qt1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QT1 Port"
::= { qt1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
qt1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { qt1-card 18 }
qt1SystemInformationEntry OBJECT-TYPE
SYNTAX QT1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { qt1Index }
::= { qt1SystemInformationTable 1 }
QT1SystemInformationEntry ::= SEQUENCE {
qt1PROMVersion DisplayString,
qt1HardwareVersion DisplayString
}
qt1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" qt1 PROM Version"
::= { qt1SystemInformationEntry 2 }
qt1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" qt1 Hardware Version"
::= { qt1SystemInformationEntry 3 }
--
-- QT1 Customer Information Table
--
qt1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF QT1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { qt1-card 99 }
qt1CustomerInfoEntry OBJECT-TYPE
SYNTAX QT1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { qt1CISlotIndex , qt1CIPortIndex }
::= { qt1CustomerInfoTable 1 }
QT1CustomerInfoEntry ::= SEQUENCE {
qt1CISlotIndex LargeSlotIndex,
qt1CIPortIndex FourPortID,
qt1CICustomerInfo DisplayString (SIZE(0..64))
}
qt1CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qt1CustomerInfoEntry 1 }
qt1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { qt1CustomerInfoEntry 2 }
qt1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { qt1CustomerInfoEntry 3 }
qt1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of QT1"
::= { qt1-card 100 }
--======================================================================--
--======================================================================--
-- g703 Card MIB
--======================================================================--
--======================================================================--
--
-- Alarm History Table
--
g703AlmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" G.703 Alarm History Table"
::= { g703-card 1 }
g703AlmHistoryEntry OBJECT-TYPE
SYNTAX G703AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX {
g703AlmHistorySlotIndex ,
g703AlmHistoryPortIndex }
::= { g703AlmHistoryTable 1 }
G703AlmHistoryEntry ::= SEQUENCE {
g703AlmHistorySlotIndex LargeSlotIndex,
g703AlmHistoryPortIndex EightPortID,
g703AlmHistoryState INTEGER,
g703AlmHistoryCount INTEGER,
g703AlmHistoryEnable AlarmSeverity
}
g703AlmHistorySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { g703AlmHistoryEntry 1 }
g703AlmHistoryPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.703 port 1-8"
::= { g703AlmHistoryEntry 2 }
g703AlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { g703AlmHistoryEntry 3 }
g703AlmHistoryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { g703AlmHistoryEntry 4 }
g703AlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { g703AlmHistoryEntry 5 }
--
-- Alarm Control Table
--
g703AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"G.703 Alarm Control Table."
::= { g703-card 2 }
g703AlarmControlEntry OBJECT-TYPE
SYNTAX G703AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.703 Alarm Control Table."
INDEX {
g703AlarmSlotIndex ,
g703AlarmPortIndex }
::= { g703AlarmControlTable 1 }
G703AlarmControlEntry ::= SEQUENCE {
g703AlarmSlotIndex LargeSlotIndex,
g703AlarmPortIndex EightPortID,
g703AlarmType INTEGER,
g703AlarmSetup AlarmSeverity
}
g703AlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { g703AlarmControlEntry 1 }
g703AlarmPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.703 port 1-8"
::= { g703AlarmControlEntry 2 }
g703AlarmType OBJECT-TYPE
SYNTAX INTEGER {
los(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type"
::= { g703AlarmControlEntry 3 }
g703AlarmSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { g703AlarmControlEntry 4 }
--
-- Line Diagnostic Control Table
--
g703LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"G.703 Diagnostic Control Table."
::= { g703-card 3 }
g703LineDiagControlEntry OBJECT-TYPE
SYNTAX G703LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of G.703 diagnostic control table."
INDEX {
g703Index ,
g703PortIndex
}
::= { g703LineDiagControlTable 1 }
G703LineDiagControlEntry ::= SEQUENCE {
g703Index LargeSlotIndex,
g703PortIndex EightPortID,
g703LoopbackType INTEGER,
g703BertControl INTEGER,
g703BertStatus INTEGER,
g703ElapseSeconds INTEGER,
g703ErrorSeconds INTEGER,
g703ErrorBits INTEGER
}
g703Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { g703LineDiagControlEntry 1 }
g703PortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 8, Total 8 ports"
::= { g703LineDiagControlEntry 2 }
g703LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-Loopback(2),
payLoad-Loopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G703 Loopback Type"
::= { g703LineDiagControlEntry 3 }
g703BertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-OFF(1),
bert-ON(2),
reset(3),
inject-Error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT control"
::= { g703LineDiagControlEntry 4 }
g703BertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-Sync(1),
bert-Unsync(2),
bert-Not-Active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT status"
::= { g703LineDiagControlEntry 5 }
g703ElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapse seconds"
::= { g703LineDiagControlEntry 6 }
g703ErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error seconds"
::= { g703LineDiagControlEntry 7 }
g703ErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error bits"
::= { g703LineDiagControlEntry 8 }
--
-- G703 Status Table
--
g703StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703Status
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.703 status table."
::= { g703-card 4 }
g703StatusEntry OBJECT-TYPE
SYNTAX G703Status
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.703 status table."
INDEX {
g703Index ,
g703PortIndex
}
::= { g703StatusTable 1 }
G703Status ::= SEQUENCE {
statusLOS INTEGER
}
statusLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.703 LOS status "
::= { g703StatusEntry 2 }
--
-- SYSTEM Information Table
--
g703SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703SystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { g703-card 5 }
g703SystemInfoEntry OBJECT-TYPE
SYNTAX G703SystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX {
g703Index
}
::= { g703SystemInformationTable 1 }
G703SystemInformation ::= SEQUENCE {
fpgaVersion DisplayString
}
fpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.703 FPGA Version"
::= { g703SystemInfoEntry 2 }
--
-- Command Control Table
--
g703CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF G703CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { g703-card 6 }
g703CommandControlEntry OBJECT-TYPE
SYNTAX G703CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { g703Index }
::= { g703CommandControlTable 1 }
G703CommandControlEntry ::= SEQUENCE {
g703AlarmHistoryReset INTEGER
}
g703AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { g703CommandControlEntry 1 }
g703TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of G703"
::= { g703-card 100 }
--======================================================================--
--======================================================================--
-- G.SHDSL-4 MIB
--======================================================================--
--======================================================================--
--
-- GDSL4 SYSTEM Table
--
gdsl4SystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4SystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system control table."
::= { gdsl4-card 1 }
gdsl4SystemEntry OBJECT-TYPE
SYNTAX Gdsl4SystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system table."
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4SysHTUIndex }
::= { gdsl4SystemTable 1 }
Gdsl4SystemEntry ::= SEQUENCE {
gdsl4Index LargeSlotIndex,
gdsl4PortIndex FourPortID,
gdsl4SysHTUIndex INTEGER,
gdsl4Mode INTEGER,
gdsl4ServiceType INTEGER,
gdsl4ClockSource INTEGER,
gdsl4Model INTEGER
}
gdsl4Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4SystemEntry 1 }
gdsl4PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1~4."
::= { gdsl4SystemEntry 2 }
gdsl4SysHTUIndex OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote"
::= { gdsl4SystemEntry 3 }
gdsl4Mode OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL mode (Master or Slave)"
::= { gdsl4SystemEntry 4 }
gdsl4ServiceType OBJECT-TYPE
SYNTAX INTEGER {
one-pair(1),
two-pairs(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Service Configuration"
::= { gdsl4SystemEntry 5 }
gdsl4ClockSource OBJECT-TYPE
SYNTAX INTEGER {
line(1),
system(2),
dte(3),
e1t1(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" System Master Clock Source"
::= { gdsl4SystemEntry 6 }
gdsl4Model OBJECT-TYPE
SYNTAX INTEGER {
rack(1),
h3300-3s(2),
h3300(3),
h3310(4),
h3304(5),
h3310-e1-brg(8),
h3310-brg(9),
other(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.shdsl model"
::= { gdsl4SystemEntry 7 }
--
-- GDSL4 Line Configuartion for Loop-1, Loop-2
--
gdsl4LineConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Line Configuration table."
::= { gdsl4-card 2 }
gdsl4LineConfigEntry OBJECT-TYPE
SYNTAX Gdsl4LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL Line Configuration table."
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4LineLoopNumber }
::= { gdsl4LineConfigTable 1 }
Gdsl4LineConfigEntry ::= SEQUENCE {
gdsl4LineLoopNumber INTEGER,
gdsl4LineRate INTEGER,
gdsl4LineCode INTEGER,
gdsl4LineNx64 INTEGER,
gdsl4CAS INTEGER,
gdsl4OOS INTEGER
}
gdsl4LineLoopNumber OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit Loop Number"
::= { gdsl4LineConfigEntry 2 }
gdsl4LineRate OBJECT-TYPE
SYNTAX INTEGER {
r0Kbps(0),
r72Kbps(1),
r136Kbps(2),
r200Kbps(3),
r264Kbps(4),
r328Kbps(5),
r392Kbps(6),
r456Kbps(7),
r520Kbps(8),
r584Kbps(9),
r648Kbps(10),
r712Kbps(11),
r776Kbps(12),
r840Kbps(13),
r904Kbps(14),
r968Kbps(15),
r1032Kbps(16),
r1096Kbps(17),
r1160Kbps(18),
r1224Kbps(19),
r1288Kbps(20),
r1352Kbps(21),
r1416Kbps(22),
r1480Kbps(23),
r1544Kbps(24),
r1608Kbps(25),
r1672Kbps(26),
r1736Kbps(27),
r1800Kbps(28),
r1864Kbps(29),
r1928Kbps(30),
r1992Kbps(31),
r2056Kbps(32)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"To describe G.SHDSL Line Rate of specified loop,
for an example: 776Kbps"
::= { gdsl4LineConfigEntry 3 }
gdsl4LineCode OBJECT-TYPE
SYNTAX INTEGER {
code-2b1q(1),
code-cap(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL Line Coding"
::= { gdsl4LineConfigEntry 4 }
gdsl4LineNx64 OBJECT-TYPE
SYNTAX INTEGER (3..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of N*64 Kbps"
::= { gdsl4LineConfigEntry 5 }
gdsl4CAS OBJECT-TYPE
SYNTAX INTEGER {
e1-cas(1),
off(2),
t1-d4-cas(3),
t1-esf-cas(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL CAS"
::= { gdsl4LineConfigEntry 6 }
gdsl4OOS OBJECT-TYPE
SYNTAX INTEGER {
b0001(1),
b0010(2),
b0011(3),
b0100(4),
b0101(5),
b0110(6),
b0111(7),
b1000(8),
b1001(9),
b1010(10),
b1011(11),
b1100(12),
b1101(13),
b1110(14),
b1111(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OOS"
::= { gdsl4LineConfigEntry 7 }
--
-- GDSL4 AI Configuartion
--
gdsl4AIConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4AIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Application Interface Configuration table."
::= { gdsl4-card 3 }
gdsl4AIConfigEntry OBJECT-TYPE
SYNTAX Gdsl4AIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL AI Configuration table."
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4AiNumber }
::= { gdsl4AIConfigTable 1 }
Gdsl4AIConfigEntry ::= SEQUENCE {
gdsl4AiNumber INTEGER,
gdsl4DteReady INTEGER,
gdsl4DteRate INTEGER,
gdsl4DteClockPolarity INTEGER,
gdsl4DteDataPolarity INTEGER,
gdsl4DteRTS INTEGER,
gdsl4DteTTM INTEGER,
gdsl4DteV54 INTEGER,
gdsl4DteInterface INTEGER,
gdsl4DS1Ready INTEGER,
gdsl4DS1Framing INTEGER,
gdsl4DS1Code INTEGER,
gdsl4DS1CAS INTEGER,
gdsl4DS1Idle INTEGER,
gdsl4T1Interf INTEGER,
gdsl4T1EquLbo INTEGER,
gdsl4DS1Map DisplayString (SIZE(32)),
gdsl4E1T1Mode INTEGER,
gdsl4AISetResponse INTEGER
}
gdsl4AiNumber OBJECT-TYPE
SYNTAX INTEGER {
-- local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote unit"
::= { gdsl4AIConfigEntry 2 }
gdsl4DteReady OBJECT-TYPE
SYNTAX INTEGER {
dte-ready(1),
dte-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE port is present or not"
::= { gdsl4AIConfigEntry 3 }
gdsl4DteRate OBJECT-TYPE
SYNTAX INTEGER {
dte64K(1),
dte128K(2),
dte192K(3),
dte256K(4),
dte320K(5),
dte384K(6),
dte448K(7),
dte512K(8),
dte576K(9),
dte640K(10),
dte704K(11),
dte768K(12),
dte832K(13),
dte896K(14),
dte960K(15),
dte1024K(16),
dte1088K(17),
dte1152K(18),
dte1216K(19),
dte1280K(20),
dte1344K(21),
dte1408K(22),
dte1472K(23),
dte1536K(24),
dte1600K(25),
dte1664K(26),
dte1728K(27),
dte1792K(28),
dte1856K(29),
dte1920K(30),
dte1984K(31),
dte2048K(32),
none(33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Base Rate"
::= { gdsl4AIConfigEntry 4 }
gdsl4DteClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clock-normal(1),
clock-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Clock Polarity"
::= { gdsl4AIConfigEntry 5 }
gdsl4DteDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
data-normal(1),
data-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Data Polarity"
::= { gdsl4AIConfigEntry 6 }
gdsl4DteRTS OBJECT-TYPE
SYNTAX INTEGER {
rts-active(1),
rts-permanent(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE RTS Mode"
::= { gdsl4AIConfigEntry 7 }
gdsl4DteTTM OBJECT-TYPE
SYNTAX INTEGER {
ttm-off(1),
ttm-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE TTM Mode"
::= { gdsl4AIConfigEntry 8 }
gdsl4DteV54 OBJECT-TYPE
SYNTAX INTEGER {
v54-off(1),
v54-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE V.54 Loopback Mode"
::= { gdsl4AIConfigEntry 9 }
gdsl4DteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
eia530-rs449(2),
x21(3),
rs232(4),
router(7),
subrate(8),
dte-e1(9),
dte-t1(10),
bridge(12),
n64-v35(17),
n64-eia530(18),
n64-x21(19),
n64-e1(25),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Interface Type"
::= { gdsl4AIConfigEntry 10 }
gdsl4DS1Ready OBJECT-TYPE
SYNTAX INTEGER {
ds1-ready(1),
ds1-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.SHDSL DS1 unit is present or not"
::= { gdsl4AIConfigEntry 11 }
gdsl4DS1Framing OBJECT-TYPE
SYNTAX INTEGER {
unframe(1),
d4(2),
esf(3),
esf-t1-403(9),
crc-off(4),
crc-on(5),
cas-crc-off(6),
cas-crc-on(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Framing"
::= { gdsl4AIConfigEntry 12 }
gdsl4DS1Code OBJECT-TYPE
SYNTAX INTEGER {
b8zs(1),
ami(2),
hdb3(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Coding"
::= { gdsl4AIConfigEntry 13 }
gdsl4DS1CAS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
none(3),
auto(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 CAS"
::= { gdsl4AIConfigEntry 14 }
gdsl4DS1Idle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Idle code"
::= { gdsl4AIConfigEntry 15 }
gdsl4T1Interf OBJECT-TYPE
SYNTAX INTEGER {
short-haul(1),
long-haul(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL T1 Interface"
::= { gdsl4AIConfigEntry 16 }
gdsl4T1EquLbo OBJECT-TYPE
SYNTAX INTEGER {
equ-0-133-feet(1),
equ-133-266-feet(2),
equ-266-399-feet(3),
equ-399-533-feet(4),
equ-533-655-feet(5),
none(6),
lbo-0db(11),
lbo-75db(12),
lbo-15db(13),
lbo-225db(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL T1 EQU/LBO"
::= { gdsl4AIConfigEntry 17 }
gdsl4DS1Map OBJECT-TYPE
SYNTAX DisplayString (SIZE(32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Map"
::= { gdsl4AIConfigEntry 19 }
gdsl4E1T1Mode OBJECT-TYPE
SYNTAX INTEGER {
e1(1),
t1(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL E1/T1 Mode"
::= { gdsl4AIConfigEntry 20 }
gdsl4AISetResponse OBJECT-TYPE
SYNTAX INTEGER {
na(1),
ok(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL Config Set response"
::= { gdsl4AIConfigEntry 99 }
--
-- GDSL4 Current Performance Table
--
gdsl4CurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4CurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl4-card 4 }
gdsl4CurrPerfEntry OBJECT-TYPE
SYNTAX Gdsl4CurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4CurrPerfTypeIndex }
::= { gdsl4CurrPerfTable 1 }
Gdsl4CurrPerfEntry ::= SEQUENCE {
gdsl4CurrPerfTypeIndex INTEGER,
gdsl4CurrES INTEGER,
gdsl4CurrSES INTEGER,
gdsl4CurrUAS INTEGER,
gdsl4Curr15MinTimeElapsed INTEGER,
gdsl4Valid15MinInterval INTEGER
}
gdsl4CurrPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl4CurrPerfEntry 2 }
gdsl4CurrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl4CurrPerfEntry 3 }
gdsl4CurrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl4CurrPerfEntry 4 }
gdsl4CurrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl4CurrPerfEntry 5 }
gdsl4Curr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { gdsl4CurrPerfEntry 6 }
gdsl4Valid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { gdsl4CurrPerfEntry 7 }
--
-- GDSL4 Total Performance Table
--
gdsl4TotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl4-card 5 }
gdsl4TotalPerfEntry OBJECT-TYPE
SYNTAX Gdsl4TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4TotalPerfTypeIndex }
::= { gdsl4TotalPerfTable 1 }
Gdsl4TotalPerfEntry ::= SEQUENCE {
gdsl4TotalPerfTypeIndex INTEGER,
gdsl4TotalES INTEGER,
gdsl4TotalSES INTEGER,
gdsl4TotalUAS INTEGER
}
gdsl4TotalPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl4TotalPerfEntry 2 }
gdsl4TotalES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl4TotalPerfEntry 3 }
gdsl4TotalSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl4TotalPerfEntry 4 }
gdsl4TotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl4TotalPerfEntry 5 }
--
-- Interval Performance Table
--
gdsl4IntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4IntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl4-card 6 }
gdsl4IntvPerfEntry OBJECT-TYPE
SYNTAX Gdsl4IntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4IntvPerfTypeIndex ,
gdsl4IntvPerfPeriod }
::= { gdsl4IntvPerfTable 1 }
Gdsl4IntvPerfEntry ::= SEQUENCE {
gdsl4IntvPerfTypeIndex INTEGER,
gdsl4IntvPerfPeriod INTEGER,
gdsl4IntvES INTEGER,
gdsl4IntvSES INTEGER,
gdsl4IntvUAS INTEGER,
gdsl4IntvAvailable INTEGER
}
gdsl4IntvPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl4IntvPerfEntry 2 }
gdsl4IntvPerfPeriod OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Interval Period Number"
::= { gdsl4IntvPerfEntry 3 }
gdsl4IntvES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl4IntvPerfEntry 4 }
gdsl4IntvSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl4IntvPerfEntry 5 }
gdsl4IntvUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl4IntvPerfEntry 6 }
gdsl4IntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { gdsl4IntvPerfEntry 7 }
--
-- GDSL4 FRACTIONAL TABLE
--
gdsl4FracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4FracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl4FracUnitIndex.gdsl4FracNumber"
::= { gdsl4-card 7 }
gdsl4FracEntry OBJECT-TYPE
SYNTAX Gdsl4FracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4FracNumber }
::= { gdsl4FracTable 1 }
Gdsl4FracEntry ::= SEQUENCE {
gdsl4FracNumber INTEGER (1..32),
gdsl4FracIfIndex INTEGER
}
gdsl4FracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"gdsl4FracNumber "
::= { gdsl4FracEntry 2 }
gdsl4FracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-dte(3),
chan-x(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"gdsl4FracIfIndex "
::= { gdsl4FracEntry 3 }
--
-- Diagnostic Control Table
--
gdsl4DiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4DiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl4-card 8 }
gdsl4DiagEntry OBJECT-TYPE
SYNTAX Gdsl4DiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4DiagTable 1 }
Gdsl4DiagEntry ::= SEQUENCE {
gdsl4LocalGshdslLoopback INTEGER,
gdsl4RemoteGshdslLoopback INTEGER,
gdsl4RemoteDteLoopback INTEGER,
gdsl4BERTControl INTEGER,
gdsl4BERTReset INTEGER,
gdsl4BERTStatus INTEGER,
gdsl4BERTCounter INTEGER,
gdsl4BERTElapsed INTEGER,
gdsl4InbandLoopbackPeriod INTEGER
}
gdsl4LocalGshdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
gshdsl-to-line(2),
gshdsl-to-local(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { gdsl4DiagEntry 2 }
gdsl4RemoteGshdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-gshdsl-to-line(2),
slave-gshdsl-to-local(3),
slave-gshdsl-to-bridge(4),
slave-gshdsl-to-dte1(82),
slave-gshdsl-to-dte2(83),
slave-gshdsl-to-dte3(84)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { gdsl4DiagEntry 4 }
gdsl4RemoteDteLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-t1-to-line(2),
slave-t1-to-local(3),
slave-e1-to-line(4),
slave-e1-to-local(5),
slave-dte-to-line(6),
slave-dte-to-local(7),
slave-router-to-line(8),
other(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE/T1/E1 Loopback Type"
::= { gdsl4DiagEntry 5 }
gdsl4BERTControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
-- bert-2-15-1(2),
bert-on(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Control"
::= { gdsl4DiagEntry 6 }
gdsl4BERTReset OBJECT-TYPE
SYNTAX INTEGER {
bert-no-action(1),
bert-restart(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Restart"
::= { gdsl4DiagEntry 7 }
gdsl4BERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { gdsl4DiagEntry 8 }
gdsl4BERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Counter"
::= { gdsl4DiagEntry 9 }
gdsl4BERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Elapsed Time"
::= { gdsl4DiagEntry 10 }
gdsl4InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of loopback"
::= { gdsl4DiagEntry 11 }
--
-- Alarm Queue Table
--
gdsl4AlmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4AlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl4AlmQueueUnitIndex "
::= { gdsl4-card 9 }
gdsl4AlmQueueEntry OBJECT-TYPE
SYNTAX Gdsl4AlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4AlmQueueNumber }
::= { gdsl4AlmQueueTable 1 }
Gdsl4AlmQueueEntry ::= SEQUENCE {
gdsl4AlmQueueNumber INTEGER (1..40),
gdsl4AlmQueueString DisplayString (SIZE(0..80))
}
gdsl4AlmQueueNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Latest Alarm Queue number (1-40)"
::= { gdsl4AlmQueueEntry 2 }
gdsl4AlmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { gdsl4AlmQueueEntry 3 }
--
-- Alarm Status Table
--
gdsl4AlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: xdslAlmStatusUnitIndex "
::= { gdsl4-card 10 }
gdsl4AlmStatusEntry OBJECT-TYPE
SYNTAX Gdsl4AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4AlmStatusNumber }
::= { gdsl4AlmStatusTable 1 }
Gdsl4AlmStatusEntry ::= SEQUENCE {
gdsl4AlmStatusNumber INTEGER (1..40),
gdsl4AlmStatusString DisplayString,
gdsl4AlmStatusThreshold INTEGER,
gdsl4AlmStatusState INTEGER,
gdsl4AlmStatusCount INTEGER,
gdsl4AlmStatusEnable AlarmSeverity
}
gdsl4AlmStatusNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Status Index "
::= { gdsl4AlmStatusEntry 2 }
gdsl4AlmStatusString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { gdsl4AlmStatusEntry 3 }
gdsl4AlmStatusThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm Threshold Value "
::= { gdsl4AlmStatusEntry 4 }
gdsl4AlmStatusState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { gdsl4AlmStatusEntry 5 }
gdsl4AlmStatusCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { gdsl4AlmStatusEntry 6 }
gdsl4AlmStatusEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { gdsl4AlmStatusEntry 7 }
--
-- Gdsl4 Status Config Table
--
gdsl4StatusConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4StatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Gdsl Status Config Configuration "
::= { gdsl4-card 11 }
gdsl4StatusConfigEntry OBJECT-TYPE
SYNTAX Gdsl4StatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4StatusConfigTable 1 }
Gdsl4StatusConfigTableEntry ::= SEQUENCE {
gdsl4DS1SYNC INTEGER,
gdsl4DS1TxAIS INTEGER,
gdsl4DS1TxRAI INTEGER,
gdsl4DS1RxAIS INTEGER,
gdsl4DS1RxRAI INTEGER,
gdsl4DS1LOS INTEGER,
gdsl4DS1LOF INTEGER,
gdsl4dteDSR INTEGER,
gdsl4dteCTS INTEGER,
gdsl4dteDCD INTEGER,
gdsl4dteDTR INTEGER,
gdsl4dteRTS INTEGER,
gdsl4PortCAS INTEGER,
gdsl4LAN1Status INTEGER,
gdsl4WAN1Status INTEGER
}
gdsl4DS1SYNC OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line status."
::= { gdsl4StatusConfigEntry 1 }
gdsl4DS1TxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gshdsl DS1 line Tx Alarm Indication Signal."
::= { gdsl4StatusConfigEntry 2 }
gdsl4DS1TxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Tx Remote Alarm Indication."
::= { gdsl4StatusConfigEntry 3 }
gdsl4DS1RxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Rx Alarm Indication Signal."
::= { gdsl4StatusConfigEntry 4 }
gdsl4DS1RxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Rx Remote Alarm Indication."
::= { gdsl4StatusConfigEntry 5 }
gdsl4DS1LOS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line LOS Status."
::= { gdsl4StatusConfigEntry 6 }
gdsl4DS1LOF OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line LOF Status."
::= { gdsl4StatusConfigEntry 7 }
gdsl4dteDSR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DSR Status."
::= { gdsl4StatusConfigEntry 8 }
gdsl4dteCTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line CTS Status."
::= { gdsl4StatusConfigEntry 9 }
gdsl4dteDCD OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DCD Status."
::= { gdsl4StatusConfigEntry 10 }
gdsl4dteDTR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DTR Status."
::= { gdsl4StatusConfigEntry 11 }
gdsl4dteRTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line RTS Status."
::= { gdsl4StatusConfigEntry 12 }
gdsl4PortCAS OBJECT-TYPE
SYNTAX INTEGER {
loss(1),
sync(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl CAS Status."
::= { gdsl4StatusConfigEntry 13 }
gdsl4LAN1Status OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LAN1 Status."
::= { gdsl4StatusConfigEntry 14 }
gdsl4WAN1Status OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" WAN1 Status."
::= { gdsl4StatusConfigEntry 15 }
--
-- GDSL4 Info Table
--
gdsl4InfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl4InfoUnitIndex "
::= { gdsl4-card 12 }
gdsl4InfoEntry OBJECT-TYPE
SYNTAX Gdsl4InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4InfoTable 1 }
Gdsl4InfoEntry ::= SEQUENCE {
gdsl4MasterNoiseMarginString DisplayString (SIZE(0..80)),
gdsl4MasterMaxNMRString DisplayString (SIZE(0..80)),
gdsl4MasterMinNMRString DisplayString (SIZE(0..80)),
gdsl4SlaveNoiseMarginString DisplayString (SIZE(0..80)),
gdsl4SlaveMaxNMRString DisplayString (SIZE(0..80)),
gdsl4SlaveMinNMRString DisplayString (SIZE(0..80))
}
gdsl4MasterNoiseMarginString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Noise Margin String"
::= { gdsl4InfoEntry 2 }
gdsl4MasterMaxNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max Noise Margin String"
::= { gdsl4InfoEntry 3 }
gdsl4MasterMinNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Min Margin String"
::= { gdsl4InfoEntry 4 }
gdsl4SlaveNoiseMarginString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Noise Margin String"
::= { gdsl4InfoEntry 5 }
gdsl4SlaveMaxNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max Noise Margin String"
::= { gdsl4InfoEntry 6 }
gdsl4SlaveMinNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Min Margin String"
::= { gdsl4InfoEntry 7 }
--
-- Command Control Table
--
gdsl4CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { gdsl4-card 13 }
gdsl4CommandControlEntry OBJECT-TYPE
SYNTAX Gdsl4CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4CommandControlTable 1 }
Gdsl4CommandControlEntry ::= SEQUENCE {
gdsl4ClearAlarmQueue INTEGER,
gdsl4ClearPerformance INTEGER,
gdsl4ClearAlarmHistory INTEGER,
gdsl4UnitReset INTEGER,
gdsl4UnitLoadDefault INTEGER,
gdsl4FarEndReset INTEGER,
gdsl4CardMode INTEGER
}
gdsl4ClearAlarmQueue OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm Queue "
::= { gdsl4CommandControlEntry 2 }
gdsl4ClearPerformance OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear User Performance"
::= { gdsl4CommandControlEntry 3 }
gdsl4ClearAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm History"
::= { gdsl4CommandControlEntry 4 }
gdsl4UnitReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset G.SHDSL-4"
::= { gdsl4CommandControlEntry 5 }
gdsl4UnitLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default G.SHDSL-4"
::= { gdsl4CommandControlEntry 6 }
gdsl4FarEndReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Far End System"
::= { gdsl4CommandControlEntry 7 }
gdsl4CardMode OBJECT-TYPE
SYNTAX INTEGER {
e1Mode(1),
t1Mode(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Set card to E1 or T1 mode, will reset card"
::= { gdsl4CommandControlEntry 8 }
--
-- SYSTEM Information Table
--
gdsl4SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { gdsl4-card 14 }
gdsl4SystemInformationEntry OBJECT-TYPE
SYNTAX Gdsl4SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { gdsl4Index }
::= { gdsl4SystemInformationTable 1 }
Gdsl4SystemInformationEntry ::= SEQUENCE {
gdsl4SoftwareVersion DisplayString,
gdsl4HardwareVersion DisplayString
}
gdsl4SoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-4 Software Version"
::= { gdsl4SystemInformationEntry 2 }
gdsl4HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-4 Hardware Version"
::= { gdsl4SystemInformationEntry 3 }
--
-- G.SHDSL-4 Customer Information Table
--
gdsl4CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { gdsl4-card 99 }
gdsl4CustomerInfoEntry OBJECT-TYPE
SYNTAX Gdsl4CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { gdsl4CISlotIndex , gdsl4CIPortIndex }
::= { gdsl4CustomerInfoTable 1 }
Gdsl4CustomerInfoEntry ::= SEQUENCE {
gdsl4CISlotIndex LargeSlotIndex,
gdsl4CIPortIndex FourPortID,
gdsl4CICustomerInfo DisplayString (SIZE(0..64))
}
gdsl4CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4CustomerInfoEntry 1 }
gdsl4CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { gdsl4CustomerInfoEntry 2 }
gdsl4CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { gdsl4CustomerInfoEntry 3 }
--
-- Daughter Card Information Table
--
gdsl4DaughterCardInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4DaughterCardInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Daughter Card Information table."
::= { gdsl4-card 15 }
gdsl4DaughterCardInfoEntry OBJECT-TYPE
SYNTAX Gdsl4DaughterCardInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the daughter card information table."
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4DaughterCardInfoTable 1 }
Gdsl4DaughterCardInfoEntry ::= SEQUENCE {
gdsl4DaughterCard INTEGER
}
gdsl4DaughterCard OBJECT-TYPE
SYNTAX INTEGER {
no-daughter-card(1),
sealing-current-single(2),
sealing-current-daul(3),
line-power-single(4),
line-power-daul(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-4 Daughter Card "
::= { gdsl4DaughterCardInfoEntry 2 }
--
-- GDSL4 ADVANCE SYSTEM Table
--
gdsl4AdvanceSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4AdvanceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system control table."
::= { gdsl4-card 16 }
gdsl4AdvanceSystemEntry OBJECT-TYPE
SYNTAX Gdsl4AdvanceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Advance system table."
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4SysHTUIndex }
::= { gdsl4AdvanceSystemTable 1 }
Gdsl4AdvanceSystemEntry ::= SEQUENCE {
gdsl4AnnexType INTEGER,
gdsl4ClockMode INTEGER,
gdsl4PSDMask INTEGER,
gdsl4PBOMode INTEGER
}
gdsl4AnnexType OBJECT-TYPE
SYNTAX INTEGER {
type-A(1),
type-B(2),
not-support(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL Annex Type"
::= { gdsl4AdvanceSystemEntry 4 }
gdsl4ClockMode OBJECT-TYPE
SYNTAX INTEGER {
plesiochronous(1),
synchronous(2),
hybrid(3),
not-support(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL Clock Mode"
::= { gdsl4AdvanceSystemEntry 5 }
gdsl4PSDMask OBJECT-TYPE
SYNTAX INTEGER {
symmetric(1),
asymmetric(2),
not-support(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL PSD Mask"
::= { gdsl4AdvanceSystemEntry 6 }
gdsl4PBOMode OBJECT-TYPE
SYNTAX INTEGER {
automatic(1),
pbo-0-db(2),
pbo-1-db(3),
pbo-2-db(4),
pbo-3-db(5),
pbo-4-db(6),
pbo-5-db(7),
pbo-6-db(8),
pbo-7-db(9),
pbo-8-db(10),
pbo-9-db(11),
pbo-10-db(12),
pbo-11-db(13),
pbo-12-db(14),
pbo-13-db(15),
pbo-14-db(16),
pbo-15-db(17),
pbo-16-db(18),
pbo-17-db(19),
pbo-18-db(20),
pbo-19-db(21),
pbo-20-db(22),
pbo-21-db(23),
pbo-22-db(24),
pbo-23-db(25),
pbo-24-db(26),
pbo-25-db(27),
pbo-26-db(28),
pbo-27-db(29),
pbo-28-db(30),
pbo-29-db(31),
pbo-30-db(32),
pbo-31-db(33),
not-support(34)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL PBO Mode"
::= { gdsl4AdvanceSystemEntry 7 }
--
-- GDSL4 Remote Link Identification Table
--
gdsl4RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Remote Link Identification Table."
::= { gdsl4-card 17 }
gdsl4RemoteLinkIDEntry OBJECT-TYPE
SYNTAX Gdsl4RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL Remote Link Identification table."
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4RemoteLinkIDTable 1 }
Gdsl4RemoteLinkIDEntry ::= SEQUENCE {
gdsl4RemoteLinkIDType INTEGER,
gdsl4RemoteLinkIDRack INTEGER,
gdsl4RemoteLinkIDSlotNumber INTEGER,
gdsl4RemoteLinkIDPort INTEGER,
gdsl4RemoteLinkIDSerialNumber INTEGER
}
gdsl4RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of remote site."
::= { gdsl4RemoteLinkIDEntry 3 }
gdsl4RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { gdsl4RemoteLinkIDEntry 4 }
gdsl4RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { gdsl4RemoteLinkIDEntry 5 }
gdsl4RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { gdsl4RemoteLinkIDEntry 6 }
gdsl4RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { gdsl4RemoteLinkIDEntry 7 }
--
-- Seven Days Performance Table
--
gdsl4SevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { gdsl4-card 18 }
gdsl4SevenDaysPerfEntry OBJECT-TYPE
SYNTAX Gdsl4SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance entry"
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4DaysPerfTypeIndex ,
gdsl4DaysIndex }
::= { gdsl4SevenDaysPerfTable 1 }
Gdsl4SevenDaysPerfEntry ::= SEQUENCE {
gdsl4DaysPerfTypeIndex INTEGER,
gdsl4DaysIndex INTEGER (1..7),
gdsl4DateStrIndex DisplayString (SIZE (0..255) ),
gdsl4SevenDaysPerfES INTEGER,
gdsl4SevenDaysPerfSES INTEGER,
gdsl4SevenDaysPerfUAS INTEGER
}
gdsl4DaysPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl4SevenDaysPerfEntry 3 }
gdsl4DaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { gdsl4SevenDaysPerfEntry 4 }
gdsl4DateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { gdsl4SevenDaysPerfEntry 5 }
gdsl4SevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl4SevenDaysPerfEntry 6 }
gdsl4SevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl4SevenDaysPerfEntry 7 }
gdsl4SevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl4SevenDaysPerfEntry 8 }
--
-- GDSL4 Remote Fractional TABLE
--
gdsl4RemoteFracTable OBJECT IDENTIFIER ::= { gdsl4-card 19 }
--
-- GDSL4 Remote Fractional Config TABLE
--
gdsl4RemoteFracConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemoteFracConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Fractional Config Table"
::= { gdsl4RemoteFracTable 1 }
gdsl4RemoteFracConfigEntry OBJECT-TYPE
SYNTAX Gdsl4RemoteFracConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Fractional Config Entry "
INDEX { gdsl4Index ,
gdsl4PortIndex ,
gdsl4RemoteFracNumber }
::= { gdsl4RemoteFracConfigTable 1 }
Gdsl4RemoteFracConfigEntry ::= SEQUENCE {
gdsl4RemoteFracNumber INTEGER,
gdsl4RemoteFracIfIndex INTEGER
}
gdsl4RemoteFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Fractional Number "
::= { gdsl4RemoteFracConfigEntry 3 }
gdsl4RemoteFracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-x(3),
chan-dte(4),
chan-ethernet(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Fractional IfIndex"
::= { gdsl4RemoteFracConfigEntry 4 }
--
-- GDSL4 Set Remote Fractional TABLE
--
gdsl4SetRemoteFracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4SetRemoteFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Set Remote Fractional Table"
::= { gdsl4RemoteFracTable 2 }
gdsl4SetRemoteFracEntry OBJECT-TYPE
SYNTAX Gdsl4SetRemoteFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Set Remote Fractional Entry "
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4SetRemoteFracTable 1 }
Gdsl4SetRemoteFracEntry ::= SEQUENCE {
gdsl4StartFracNumber INTEGER,
gdsl4FracNumbers INTEGER,
gdsl4E1T1ClearStartFracNumber INTEGER,
gdsl4SetFracIfIndex INTEGER
}
gdsl4StartFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Start Fractional Number "
::= { gdsl4SetRemoteFracEntry 3 }
gdsl4FracNumbers OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of Fractional"
::= { gdsl4SetRemoteFracEntry 4 }
gdsl4E1T1ClearStartFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote E1/T1 Clear Start Fractional Number"
::= { gdsl4SetRemoteFracEntry 5 }
gdsl4SetFracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-x(3),
chan-dte(4),
chan-ethernet(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Fractional IfIndex"
::= { gdsl4SetRemoteFracEntry 6 }
--
-- Remote Bert Control Table
--
gdsl4RemoteBertTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemoteBertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl4-card 20 }
gdsl4RemoteBertEntry OBJECT-TYPE
SYNTAX Gdsl4RemoteBertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { gdsl4Index ,
gdsl4PortIndex }
::= { gdsl4RemoteBertTable 1 }
Gdsl4RemoteBertEntry ::= SEQUENCE {
gdsl4RemBertPatternType INTEGER,
gdsl4RemBertTestChannel INTEGER,
gdsl4RemBertTestControl INTEGER,
gdsl4RemBertStatus INTEGER,
gdsl4RemBertErrSecond INTEGER,
gdsl4RemBertErrCounter INTEGER,
gdsl4RemBertElapsedSecond INTEGER,
gdsl4RemBertUnsyncSecond INTEGER
}
gdsl4RemBertPatternType OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
-- off(1),
bert-2-15-1(2),
bert-qrss(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Pattern Type"
::= { gdsl4RemoteBertEntry 3 }
gdsl4RemBertTestChannel OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
full(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Test Channel Type"
::= { gdsl4RemoteBertEntry 4 }
gdsl4RemBertTestControl OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
disable(1),
enable(2),
reset(3),
insert-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Test Control"
::= { gdsl4RemoteBertEntry 5 }
gdsl4RemBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-unsync(1),
bert-sync(2),
bert-not-active(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Status"
::= { gdsl4RemoteBertEntry 6 }
gdsl4RemBertErrSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Error Seconds"
::= { gdsl4RemoteBertEntry 7 }
gdsl4RemBertErrCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Error Counter"
::= { gdsl4RemoteBertEntry 8 }
gdsl4RemBertElapsedSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Elapsed Time"
::= { gdsl4RemoteBertEntry 9 }
gdsl4RemBertUnsyncSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Unsync Time"
::= { gdsl4RemoteBertEntry 10 }
--
-- G.shdsl card Remote Router Table
--
gdsl4RouterConfig OBJECT IDENTIFIER ::= { gdsl4-card 21 }
--
-- G.shdsl card remote NI Control Table
--
gdsl4RtrNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Table"
::= { gdsl4RouterConfig 1 }
gdsl4RouterNiControlEntry OBJECT-TYPE
SYNTAX Gdsl4RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Entry"
INDEX { gdsl4RtrNiUnitIndex ,
gdsl4RtrNiPortIndex ,
gdsl4RtrNiIndex }
::= { gdsl4RtrNiControlTable 1 }
Gdsl4RtrNiControlEntry ::= SEQUENCE {
gdsl4RtrNiUnitIndex LargeSlotIndex,
gdsl4RtrNiPortIndex FourPortID,
gdsl4RtrNiIndex INTEGER,
gdsl4RtrIPAddr IpAddress,
gdsl4RtrSubnetMask IpAddress,
gdsl4RtrFrame INTEGER,
gdsl4RtrRIP1 INTEGER,
gdsl4RtrRIP2 INTEGER,
gdsl4RtrMode INTEGER
}
gdsl4RtrNiUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RouterNiControlEntry 1 }
gdsl4RtrNiPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RouterNiControlEntry 2 }
gdsl4RtrNiIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Ni index"
::= { gdsl4RouterNiControlEntry 3 }
gdsl4RtrIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR IP Address"
::= { gdsl4RouterNiControlEntry 4 }
gdsl4RtrSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR net mask"
::= { gdsl4RouterNiControlEntry 5 }
gdsl4RtrFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
ethernet(4),
na(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Layer2 frame"
::= { gdsl4RouterNiControlEntry 6 }
gdsl4RtrRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP1"
::= { gdsl4RouterNiControlEntry 7 }
gdsl4RtrRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP2"
::= { gdsl4RouterNiControlEntry 8 }
gdsl4RtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR mode"
::= { gdsl4RouterNiControlEntry 9 }
--
-- G.shdsl card remote Route Table
--
gdsl4RtrRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Table"
::= { gdsl4RouterConfig 2 }
gdsl4RouterRouteControlEntry OBJECT-TYPE
SYNTAX Gdsl4RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Entry"
INDEX { gdsl4RtrRUnitIndex ,
gdsl4RtrRPortIndex ,
gdsl4RtrEntry }
::= { gdsl4RtrRouteControlTable 1 }
Gdsl4RtrRouteControlEntry ::= SEQUENCE {
gdsl4RtrRUnitIndex LargeSlotIndex,
gdsl4RtrRPortIndex FourPortID,
gdsl4RtrEntry INTEGER (1..16),
gdsl4RtrNetAddr IpAddress,
gdsl4RtrNetMask IpAddress,
gdsl4RtrGatewayAddr IpAddress,
gdsl4RtrNIAddr IpAddress,
gdsl4RtrMetric INTEGER,
gdsl4RtrInterface INTEGER
}
gdsl4RtrRUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RouterRouteControlEntry 1 }
gdsl4RtrRPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RouterRouteControlEntry 2 }
gdsl4RtrEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Route Entry"
::= { gdsl4RouterRouteControlEntry 3 }
gdsl4RtrNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net Address"
::= { gdsl4RouterRouteControlEntry 4 }
gdsl4RtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net mask"
::= { gdsl4RouterRouteControlEntry 5 }
gdsl4RtrGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route gateway Address"
::= { gdsl4RouterRouteControlEntry 6 }
gdsl4RtrNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route NI Address"
::= { gdsl4RouterRouteControlEntry 7 }
gdsl4RtrMetric OBJECT-TYPE
SYNTAX INTEGER {
na(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Route metric"
::= { gdsl4RouterRouteControlEntry 8 }
gdsl4RtrInterface OBJECT-TYPE
SYNTAX INTEGER {
na(1),
lan(2),
wan(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Router Interface"
::= { gdsl4RouterRouteControlEntry 9 }
--
-- G.shdsl card remote Router Command
--
gdsl4RtrCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Table"
::= { gdsl4RouterConfig 3 }
gdsl4RtrCommandEntry OBJECT-TYPE
SYNTAX Gdsl4RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Entry"
INDEX { gdsl4RtrCmdUnitIndex ,
gdsl4RtrCmdPortIndex }
::= { gdsl4RtrCommandTable 1 }
Gdsl4RtrCmdEntry ::= SEQUENCE {
gdsl4RtrCmdUnitIndex LargeSlotIndex,
gdsl4RtrCmdPortIndex FourPortID,
gdsl4RtrCommand INTEGER,
gdsl4CRCtransparency INTEGER
}
gdsl4RtrCmdUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RtrCommandEntry 1 }
gdsl4RtrCmdPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RtrCommandEntry 2 }
gdsl4RtrCommand OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
load-default(2),
none(3),
re-get-map-cfg(11),
re-get-ni-cfg(12),
re-get-rtr-cfg(13),
re-get-crc-cfg(14),
re-get-all-cfg(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Command(reset or load-default)"
::= { gdsl4RtrCommandEntry 3 }
gdsl4CRCtransparency OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CRC transparency"
::= { gdsl4RtrCommandEntry 4 }
--
-- G.shdsl card remote Router Map
--
gdsl4RtrMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Table"
::= { gdsl4RouterConfig 4 }
gdsl4RtrMapEntry OBJECT-TYPE
SYNTAX Gdsl4RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Entry"
INDEX { gdsl4RtrMapUnitIndex ,
gdsl4RtrMapPortIndex ,
gdsl4RtrMapTsIndex }
::= { gdsl4RtrMapTable 1 }
Gdsl4RtrMappingEntry ::= SEQUENCE {
gdsl4RtrMapUnitIndex LargeSlotIndex,
gdsl4RtrMapPortIndex FourPortID,
gdsl4RtrMapTsIndex TimeslotID,
gdsl4RtrCh INTEGER
}
gdsl4RtrMapUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RtrMapEntry 1 }
gdsl4RtrMapPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RtrMapEntry 2 }
gdsl4RtrMapTsIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Timeslot 1~32, total 32 timeslots."
::= { gdsl4RtrMapEntry 3 }
gdsl4RtrCh OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"channel map data"
::= { gdsl4RtrMapEntry 4 }
--
-- G.shdsl card remote Bridge Config
--
gdsl4RemoteBridgeConfig OBJECT IDENTIFIER ::= { gdsl4-card 22 }
-- G.shdsl card remote Bridge: config table
gdsl4RemBridgeTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Bridge Table"
::= { gdsl4RemoteBridgeConfig 1 }
gdsl4RemBridgeEntry OBJECT-TYPE
SYNTAX Gdsl4RemBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Bridge Entry"
INDEX { gdsl4RBSlotIndex ,
gdsl4RBPortIndex }
::= { gdsl4RemBridgeTable 1 }
Gdsl4RemBridgeEntry ::= SEQUENCE {
gdsl4RBSlotIndex LargeSlotIndex,
gdsl4RBPortIndex FourPortID,
gdsl4RemBrgAgeTime INTEGER (10..1000000),
gdsl4RemBrgCRC INTEGER,
gdsl4RemBrgLanSpeed INTEGER
-- gdsl4RemBrgLan2Speed INTEGER
}
gdsl4RBSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RemBridgeEntry 1 }
gdsl4RBPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RemBridgeEntry 2 }
gdsl4RemBrgAgeTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: Age time 10~1000000 seconds."
::= { gdsl4RemBridgeEntry 3 }
gdsl4RemBrgCRC OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: CRC"
::= { gdsl4RemBridgeEntry 4 }
gdsl4RemBrgLanSpeed OBJECT-TYPE
SYNTAX INTEGER {
no(0),
half-duplex-10M(1),
full-duplex-10M(2),
half-duplex-100M(3),
full-duplex-100M(4),
auto-negotiation(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: LAN1 speed"
::= { gdsl4RemBridgeEntry 5 }
-- gdsl4RemBrgLan2Speed OBJECT-TYPE
-- SYNTAX INTEGER {
-- no(0),
-- half-duplex-10M(1),
-- full-duplex-10M(2),
-- half-duplex-100M(3),
-- full-duplex-100M(4),
-- auto-negotiation(5)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Remote Bridge: LAN2 speed"
-- ::= { gdsl4RemBridgeEntry 6 }
-- G.shdsl card remote VLAN: VLAN State Table
gdsl4RemVlanStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemVlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN State Table"
::= { gdsl4RemoteBridgeConfig 2 }
gdsl4RemVlanStateEntry OBJECT-TYPE
SYNTAX Gdsl4RemVlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN State Entry"
INDEX { gdsl4RVSSlotIndex ,
gdsl4RVSPortIndex }
::= { gdsl4RemVlanStateTable 1 }
Gdsl4RemVlanStateEntry ::= SEQUENCE {
gdsl4RVSSlotIndex LargeSlotIndex,
gdsl4RVSPortIndex FourPortID,
gdsl4RemVlanEnable INTEGER,
gdsl4RemVlanMgmtVID INTEGER (1..4095),
gdsl4RemVlanRegenCRC INTEGER
}
gdsl4RVSSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RemVlanStateEntry 1 }
gdsl4RVSPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RemVlanStateEntry 2 }
gdsl4RemVlanEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: disable or enable"
::= { gdsl4RemVlanStateEntry 3 }
gdsl4RemVlanMgmtVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Magement VID"
::= { gdsl4RemVlanStateEntry 4 }
gdsl4RemVlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: regenate CRC"
::= { gdsl4RemVlanStateEntry 5 }
-- G.shdsl card remote Bridge: VLAN Control Table
gdsl4RemVlanControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemVlanControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Control Table"
::= { gdsl4RemoteBridgeConfig 3 }
gdsl4RemVlanControlEntry OBJECT-TYPE
SYNTAX Gdsl4RemVlanControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Control Entry"
INDEX { gdsl4RVCSlotIndex ,
gdsl4RVCPortIndex }
::= { gdsl4RemVlanControlTable 1 }
Gdsl4RemVlanControlEntry ::= SEQUENCE {
gdsl4RVCSlotIndex LargeSlotIndex,
gdsl4RVCPortIndex FourPortID,
gdsl4RemVlanVID INTEGER (1..4095),
gdsl4RemVlanTAG INTEGER,
gdsl4RemVlanMember INTEGER,
gdsl4RemVlanCommand INTEGER,
gdsl4RemVlanResponse INTEGER
}
gdsl4RVCSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RemVlanControlEntry 1 }
gdsl4RVCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RemVlanControlEntry 2 }
gdsl4RemVlanVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl4RemVlanControlEntry 4 }
gdsl4RemVlanTAG OBJECT-TYPE
SYNTAX INTEGER {
untag(1),
tag(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: UNTAG or TAG"
::= { gdsl4RemVlanControlEntry 5 }
gdsl4RemVlanMember OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Member is LAN1 or WAN1"
::= { gdsl4RemVlanControlEntry 6 }
gdsl4RemVlanCommand OBJECT-TYPE
SYNTAX INTEGER {
create-vid(1),
add-member(2),
deactive-vid(3),
remove-member(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: command"
::= { gdsl4RemVlanControlEntry 11 }
gdsl4RemVlanResponse OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
vid-created-before(2),
vid-not-created-before(3),
not-empty(4),
no-response(11),
not-available(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: Set response"
::= { gdsl4RemVlanControlEntry 12 }
-- G.shdsl card remote Bridge: VLAN List Table
gdsl4RemVlanListTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemVlanListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN List Table"
::= { gdsl4RemoteBridgeConfig 4 }
gdsl4RemVlanListEntry OBJECT-TYPE
SYNTAX Gdsl4RemVlanListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN List Entry"
INDEX { gdsl4RVLSlotIndex ,
gdsl4RVLPortIndex ,
gdsl4RVLVLanIndex }
::= { gdsl4RemVlanListTable 1 }
Gdsl4RemVlanListEntry ::= SEQUENCE {
gdsl4RVLSlotIndex LargeSlotIndex,
gdsl4RVLPortIndex FourPortID,
gdsl4RVLVLanIndex INTEGER,
gdsl4RVLVlanVID INTEGER (1..4095),
gdsl4RVLVlanTAGmember DisplayString,
gdsl4RVLVlanUNTAGmember DisplayString
}
gdsl4RVLSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RemVlanListEntry 1 }
gdsl4RVLPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RemVlanListEntry 2 }
gdsl4RVLVLanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VLAN list index"
::= { gdsl4RemVlanListEntry 3 }
gdsl4RVLVlanVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl4RemVlanListEntry 4 }
gdsl4RVLVlanTAGmember OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: TAG member"
::= { gdsl4RemVlanListEntry 5 }
gdsl4RVLVlanUNTAGmember OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: UNTAG member"
::= { gdsl4RemVlanListEntry 6 }
-- G.shdsl card remote Bridge: VLAN Port Table
gdsl4RemVlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl4RemVlanPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Port Table"
::= { gdsl4RemoteBridgeConfig 5 }
gdsl4RemVlanPortEntry OBJECT-TYPE
SYNTAX Gdsl4RemVlanPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Port Entry"
INDEX { gdsl4RVPSlotIndex ,
gdsl4RVPPortIndex ,
gdsl4RVPVPIndex }
::= { gdsl4RemVlanPortTable 1 }
Gdsl4RemVlanPortEntry ::= SEQUENCE {
gdsl4RVPSlotIndex LargeSlotIndex,
gdsl4RVPPortIndex FourPortID,
gdsl4RVPVPIndex INTEGER,
gdsl4RVPVlanPVID INTEGER (1..4095),
gdsl4RVPVlanFrameType INTEGER,
gdsl4RVPVlanIngressFilter INTEGER,
gdsl4RVPSetResponse INTEGER
}
gdsl4RVPSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl4RemVlanPortEntry 1 }
gdsl4RVPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl4RemVlanPortEntry 2 }
gdsl4RVPVPIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VLAN Port index"
::= { gdsl4RemVlanPortEntry 3 }
gdsl4RVPVlanPVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl4RemVlanPortEntry 4 }
gdsl4RVPVlanFrameType OBJECT-TYPE
SYNTAX INTEGER {
all(1),
tag-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Frame Type"
::= { gdsl4RemVlanPortEntry 5 }
gdsl4RVPVlanIngressFilter OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Ingress Filter"
::= { gdsl4RemVlanPortEntry 6 }
gdsl4RVPSetResponse OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
vid-not-created-before(3),
no-response(11),
not-available(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: Set response"
::= { gdsl4RemVlanPortEntry 7 }
gdsl4TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 4GH"
::= { gdsl4-card 100 }
--======================================================================--
--======================================================================--
-- G.SHDSL-2 MIB
--======================================================================--
--======================================================================--
--
-- GDSL2 SYSTEM Table
--
gdsl2SystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2SystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system control table."
::= { gdsl2-card 1 }
gdsl2SystemEntry OBJECT-TYPE
SYNTAX Gdsl2SystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system table."
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2SysHTUIndex }
::= { gdsl2SystemTable 1 }
Gdsl2SystemEntry ::= SEQUENCE {
gdsl2Index LargeSlotIndex,
gdsl2PortIndex G2PortID,
gdsl2SysHTUIndex INTEGER,
gdsl2Mode INTEGER,
gdsl2ServiceType INTEGER,
gdsl2ClockSource INTEGER,
gdsl2Model INTEGER
}
gdsl2Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2SystemEntry 1 }
gdsl2PortIndex OBJECT-TYPE
SYNTAX G2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1/3, total 2 ports."
::= { gdsl2SystemEntry 2 }
gdsl2SysHTUIndex OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote"
::= { gdsl2SystemEntry 3 }
gdsl2Mode OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL mode (Master or Slave)"
::= { gdsl2SystemEntry 4 }
gdsl2ServiceType OBJECT-TYPE
SYNTAX INTEGER {
one-pair(1),
two-pairs(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Service Configuration"
::= { gdsl2SystemEntry 5 }
gdsl2ClockSource OBJECT-TYPE
SYNTAX INTEGER {
line(1),
system(2),
dte(3),
e1t1(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" System Master Clock Source"
::= { gdsl2SystemEntry 6 }
gdsl2Model OBJECT-TYPE
SYNTAX INTEGER {
rack(1),
h3300-3s(2),
h3300(3),
h3310(4),
h3304(5),
h3310-e1-brg(8),
h3310-brg(9),
other(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.shdsl model"
::= { gdsl2SystemEntry 7 }
--
-- GDSL2 Line Configuartion for Loop-1, Loop-2
--
gdsl2LineConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Line Configuration table."
::= { gdsl2-card 2 }
gdsl2LineConfigEntry OBJECT-TYPE
SYNTAX Gdsl2LineConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL Line Configuration table."
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2LineLoopIndex }
::= { gdsl2LineConfigTable 1 }
Gdsl2LineConfigEntry ::= SEQUENCE {
gdsl2LineLoopIndex INTEGER,
gdsl2LineRate INTEGER,
gdsl2LineCode INTEGER,
gdsl2LineLoopNum INTEGER,
gdsl2LineNx64 INTEGER,
gdsl2CAS INTEGER,
gdsl2OOS INTEGER
}
gdsl2LineLoopIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit Loop Number"
::= { gdsl2LineConfigEntry 2 }
gdsl2LineRate OBJECT-TYPE
SYNTAX INTEGER {
r0Kbps(0),
r72Kbps(1),
r136Kbps(2),
r200Kbps(3),
r264Kbps(4),
r328Kbps(5),
r392Kbps(6),
r456Kbps(7),
r520Kbps(8),
r584Kbps(9),
r648Kbps(10),
r712Kbps(11),
r776Kbps(12),
r840Kbps(13),
r904Kbps(14),
r968Kbps(15),
r1032Kbps(16),
r1096Kbps(17),
r1160Kbps(18),
r1224Kbps(19),
r1288Kbps(20),
r1352Kbps(21),
r1416Kbps(22),
r1480Kbps(23),
r1544Kbps(24),
r1608Kbps(25),
r1672Kbps(26),
r1736Kbps(27),
r1800Kbps(28),
r1864Kbps(29),
r1928Kbps(30),
r1992Kbps(31),
r2056Kbps(32)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"To describe G.SHDSL Line Rate of specified loop,
for an example: 776Kbps"
::= { gdsl2LineConfigEntry 3 }
gdsl2LineCode OBJECT-TYPE
SYNTAX INTEGER {
code-2b1q(1),
code-cap(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL Line Coding"
::= { gdsl2LineConfigEntry 4 }
gdsl2LineLoopNum OBJECT-TYPE
SYNTAX INTEGER {
loop-one(1),
loop-two(2),
two-loops(3),
one-one(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" gdsl Loop number"
::= { gdsl2LineConfigEntry 5 }
gdsl2LineNx64 OBJECT-TYPE
SYNTAX INTEGER (3..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of N*64 Kbps"
::= { gdsl2LineConfigEntry 6 }
gdsl2CAS OBJECT-TYPE
SYNTAX INTEGER {
e1-cas(1),
off(2),
t1-d4-cas(3),
t1-esf-cas(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL CAS"
::= { gdsl2LineConfigEntry 7 }
gdsl2OOS OBJECT-TYPE
SYNTAX INTEGER {
b0001(1),
b0010(2),
b0011(3),
b0100(4),
b0101(5),
b0110(6),
b0111(7),
b1000(8),
b1001(9),
b1010(10),
b1011(11),
b1100(12),
b1101(13),
b1110(14),
b1111(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OOS"
::= { gdsl2LineConfigEntry 8 }
--
-- GDSL2 AI Configuartion
--
gdsl2AIConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2AIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Application Interface Configuration table."
::= { gdsl2-card 3 }
gdsl2AIConfigEntry OBJECT-TYPE
SYNTAX Gdsl2AIConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL AI Configuration table."
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2AiNumber }
::= { gdsl2AIConfigTable 1 }
Gdsl2AIConfigEntry ::= SEQUENCE {
gdsl2AiNumber INTEGER,
gdsl2DteReady INTEGER,
gdsl2DteRate INTEGER,
gdsl2DteClockPolarity INTEGER,
gdsl2DteDataPolarity INTEGER,
gdsl2DteRTS INTEGER,
gdsl2DteTTM INTEGER,
gdsl2DteV54 INTEGER,
gdsl2DteInterface INTEGER,
gdsl2DS1Ready INTEGER,
gdsl2DS1Framing INTEGER,
gdsl2DS1Code INTEGER,
gdsl2DS1CAS INTEGER,
gdsl2DS1Idle INTEGER,
gdsl2T1Interf INTEGER,
gdsl2T1EquLbo INTEGER,
gdsl2DS1Map DisplayString (SIZE(32)),
gdsl2E1T1Mode INTEGER,
gdsl2AISetResponse INTEGER
}
gdsl2AiNumber OBJECT-TYPE
SYNTAX INTEGER {
-- local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Local or Remote unit"
::= { gdsl2AIConfigEntry 2 }
gdsl2DteReady OBJECT-TYPE
SYNTAX INTEGER {
dte-ready(1),
dte-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE port is present or not"
::= { gdsl2AIConfigEntry 3 }
gdsl2DteRate OBJECT-TYPE
SYNTAX INTEGER {
dte64K(1),
dte128K(2),
dte192K(3),
dte256K(4),
dte320K(5),
dte384K(6),
dte448K(7),
dte512K(8),
dte576K(9),
dte640K(10),
dte704K(11),
dte768K(12),
dte832K(13),
dte896K(14),
dte960K(15),
dte1024K(16),
dte1088K(17),
dte1152K(18),
dte1216K(19),
dte1280K(20),
dte1344K(21),
dte1408K(22),
dte1472K(23),
dte1536K(24),
dte1600K(25),
dte1664K(26),
dte1728K(27),
dte1792K(28),
dte1856K(29),
dte1920K(30),
dte1984K(31),
dte2048K(32),
none(33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Base Rate"
::= { gdsl2AIConfigEntry 4 }
gdsl2DteClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clock-normal(1),
clock-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Clock Polarity"
::= { gdsl2AIConfigEntry 5 }
gdsl2DteDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
data-normal(1),
data-inverted(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Data Polarity"
::= { gdsl2AIConfigEntry 6 }
gdsl2DteRTS OBJECT-TYPE
SYNTAX INTEGER {
rts-active(1),
rts-permanent(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE RTS Mode"
::= { gdsl2AIConfigEntry 7 }
gdsl2DteTTM OBJECT-TYPE
SYNTAX INTEGER {
ttm-off(1),
ttm-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE TTM Mode"
::= { gdsl2AIConfigEntry 8 }
gdsl2DteV54 OBJECT-TYPE
SYNTAX INTEGER {
v54-off(1),
v54-on(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE V.54 Loopback Mode"
::= { gdsl2AIConfigEntry 9 }
gdsl2DteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
eia530-rs449(2),
x21(3),
rs232(4),
router(7),
subrate(8),
dte-e1(9),
dte-t1(10),
bridge(12),
n64-v35(17),
n64-eia530(18),
n64-x21(19),
n64-e1(25),
none(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL DTE Interface Type"
::= { gdsl2AIConfigEntry 10 }
gdsl2DS1Ready OBJECT-TYPE
SYNTAX INTEGER {
ds1-ready(1),
ds1-not-ready(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"G.SHDSL DS1 unit is present or not"
::= { gdsl2AIConfigEntry 11 }
gdsl2DS1Framing OBJECT-TYPE
SYNTAX INTEGER {
unframe(1),
d4(2),
esf(3),
esf-t1-403(9),
crc-off(4),
crc-on(5),
cas-crc-off(6),
cas-crc-on(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Framing"
::= { gdsl2AIConfigEntry 12 }
gdsl2DS1Code OBJECT-TYPE
SYNTAX INTEGER {
b8zs(1),
ami(2),
hdb3(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Coding"
::= { gdsl2AIConfigEntry 13 }
gdsl2DS1CAS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
none(3),
auto(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 CAS"
::= { gdsl2AIConfigEntry 14 }
gdsl2DS1Idle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Idle code"
::= { gdsl2AIConfigEntry 15 }
gdsl2T1Interf OBJECT-TYPE
SYNTAX INTEGER {
short-haul(1),
long-haul(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL T1 Interface"
::= { gdsl2AIConfigEntry 16 }
gdsl2T1EquLbo OBJECT-TYPE
SYNTAX INTEGER {
equ-0-133-feet(1),
equ-133-266-feet(2),
equ-266-399-feet(3),
equ-399-533-feet(4),
equ-533-655-feet(5),
none(6),
lbo-0db(11),
lbo-75db(12),
lbo-15db(13),
lbo-225db(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL T1 EQU/LBO"
::= { gdsl2AIConfigEntry 17 }
gdsl2DS1Map OBJECT-TYPE
SYNTAX DisplayString (SIZE(32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL DS1 Map"
::= { gdsl2AIConfigEntry 19 }
gdsl2E1T1Mode OBJECT-TYPE
SYNTAX INTEGER {
e1(1),
t1(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL E1/T1 Mode"
::= { gdsl2AIConfigEntry 20 }
gdsl2AISetResponse OBJECT-TYPE
SYNTAX INTEGER {
na(1),
ok(2),
fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL Config Set response"
::= { gdsl2AIConfigEntry 99 }
--
-- GDSL2 Current Performance Table
--
gdsl2CurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2CurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl2-card 4 }
gdsl2CurrPerfEntry OBJECT-TYPE
SYNTAX Gdsl2CurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2CurrPerfTypeIndex }
::= { gdsl2CurrPerfTable 1 }
Gdsl2CurrPerfEntry ::= SEQUENCE {
gdsl2CurrPerfTypeIndex INTEGER,
gdsl2CurrES INTEGER,
gdsl2CurrSES INTEGER,
gdsl2CurrUAS INTEGER,
gdsl2Curr15MinTimeElapsed INTEGER,
gdsl2Valid15MinInterval INTEGER
}
gdsl2CurrPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl2CurrPerfEntry 2 }
gdsl2CurrES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl2CurrPerfEntry 3 }
gdsl2CurrSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl2CurrPerfEntry 4 }
gdsl2CurrUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl2CurrPerfEntry 5 }
gdsl2Curr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { gdsl2CurrPerfEntry 6 }
gdsl2Valid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { gdsl2CurrPerfEntry 7 }
--
-- GDSL2 Total Performance Table
--
gdsl2TotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl2-card 5 }
gdsl2TotalPerfEntry OBJECT-TYPE
SYNTAX Gdsl2TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2TotalPerfTypeIndex }
::= { gdsl2TotalPerfTable 1 }
Gdsl2TotalPerfEntry ::= SEQUENCE {
gdsl2TotalPerfTypeIndex INTEGER,
gdsl2TotalES INTEGER,
gdsl2TotalSES INTEGER,
gdsl2TotalUAS INTEGER
}
gdsl2TotalPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl2TotalPerfEntry 2 }
gdsl2TotalES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl2TotalPerfEntry 3 }
gdsl2TotalSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl2TotalPerfEntry 4 }
gdsl2TotalUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl2TotalPerfEntry 5 }
--
-- Interval Performance Table
--
gdsl2IntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2IntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl2-card 6 }
gdsl2IntvPerfEntry OBJECT-TYPE
SYNTAX Gdsl2IntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2IntvPerfTypeIndex ,
gdsl2IntvPerfPeriod }
::= { gdsl2IntvPerfTable 1 }
Gdsl2IntvPerfEntry ::= SEQUENCE {
gdsl2IntvPerfTypeIndex INTEGER,
gdsl2IntvPerfPeriod INTEGER,
gdsl2IntvES INTEGER,
gdsl2IntvSES INTEGER,
gdsl2IntvUAS INTEGER,
gdsl2IntvAvailable INTEGER
}
gdsl2IntvPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl2IntvPerfEntry 2 }
gdsl2IntvPerfPeriod OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Interval Period Number"
::= { gdsl2IntvPerfEntry 3 }
gdsl2IntvES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl2IntvPerfEntry 4 }
gdsl2IntvSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl2IntvPerfEntry 5 }
gdsl2IntvUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl2IntvPerfEntry 6 }
gdsl2IntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { gdsl2IntvPerfEntry 7 }
--
-- GDSL2 FRACTIONAL TABLE
--
gdsl2FracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2FracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl2FracUnitIndex.gdsl2FracNumber"
::= { gdsl2-card 7 }
gdsl2FracEntry OBJECT-TYPE
SYNTAX Gdsl2FracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2FracNumber }
::= { gdsl2FracTable 1 }
Gdsl2FracEntry ::= SEQUENCE {
gdsl2FracNumber INTEGER (1..32),
gdsl2FracIfIndex INTEGER
}
gdsl2FracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"gdsl2FracNumber "
::= { gdsl2FracEntry 2 }
gdsl2FracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-dte(3),
chan-x(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"gdsl2FracIfIndex "
::= { gdsl2FracEntry 3 }
--
-- Diagnostic Control Table
--
gdsl2DiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2DiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl2-card 8 }
gdsl2DiagEntry OBJECT-TYPE
SYNTAX Gdsl2DiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2DiagTable 1 }
Gdsl2DiagEntry ::= SEQUENCE {
gdsl2LocalGshdslLoopback INTEGER,
gdsl2RemoteGshdslLoopback INTEGER,
gdsl2RemoteDteLoopback INTEGER,
gdsl2BERTControl INTEGER,
gdsl2BERTReset INTEGER,
gdsl2BERTStatus INTEGER,
gdsl2BERTCounter INTEGER,
gdsl2BERTElapsed INTEGER,
gdsl2InbandLoopbackPeriod INTEGER
}
gdsl2LocalGshdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
gshdsl-to-line(2),
gshdsl-to-local(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { gdsl2DiagEntry 2 }
gdsl2RemoteGshdslLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-gshdsl-to-line(2),
slave-gshdsl-to-local(3),
slave-gshdsl-to-bridge(4),
slave-gshdsl-to-dte1(82),
slave-gshdsl-to-dte2(83),
slave-gshdsl-to-dte3(84)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSU Loopback Type"
::= { gdsl2DiagEntry 4 }
gdsl2RemoteDteLoopback OBJECT-TYPE
SYNTAX INTEGER {
slave-no-loopback(1),
slave-t1-to-line(2),
slave-t1-to-local(3),
slave-e1-to-line(4),
slave-e1-to-local(5),
slave-dte-to-line(6),
slave-dte-to-local(7),
slave-router-to-line(8),
other(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE/T1/E1 Loopback Type"
::= { gdsl2DiagEntry 5 }
gdsl2BERTControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
-- bert-2-15-1(2),
bert-on(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Control"
::= { gdsl2DiagEntry 6 }
gdsl2BERTReset OBJECT-TYPE
SYNTAX INTEGER {
bert-no-action(1),
bert-restart(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Restart"
::= { gdsl2DiagEntry 7 }
gdsl2BERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { gdsl2DiagEntry 8 }
gdsl2BERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Counter"
::= { gdsl2DiagEntry 9 }
gdsl2BERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Elapsed Time"
::= { gdsl2DiagEntry 10 }
gdsl2InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of loopback"
::= { gdsl2DiagEntry 11 }
--
-- Alarm Queue Table
--
gdsl2AlmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2AlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl2AlmQueueUnitIndex "
::= { gdsl2-card 9 }
gdsl2AlmQueueEntry OBJECT-TYPE
SYNTAX Gdsl2AlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2AlmQueueNumber }
::= { gdsl2AlmQueueTable 1 }
Gdsl2AlmQueueEntry ::= SEQUENCE {
gdsl2AlmQueueNumber INTEGER (1..40),
gdsl2AlmQueueString DisplayString (SIZE(0..80))
}
gdsl2AlmQueueNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Latest Alarm Queue number (1-40)"
::= { gdsl2AlmQueueEntry 2 }
gdsl2AlmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { gdsl2AlmQueueEntry 3 }
--
-- Alarm Status Table
--
gdsl2AlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: xdslAlmStatusUnitIndex "
::= { gdsl2-card 10 }
gdsl2AlmStatusEntry OBJECT-TYPE
SYNTAX Gdsl2AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2AlmStatusNumber }
::= { gdsl2AlmStatusTable 1 }
Gdsl2AlmStatusEntry ::= SEQUENCE {
gdsl2AlmStatusNumber INTEGER (1..40),
gdsl2AlmStatusString DisplayString,
gdsl2AlmStatusThreshold INTEGER,
gdsl2AlmStatusState INTEGER,
gdsl2AlmStatusCount INTEGER,
gdsl2AlmStatusEnable AlarmSeverity
}
gdsl2AlmStatusNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Status Index "
::= { gdsl2AlmStatusEntry 2 }
gdsl2AlmStatusString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { gdsl2AlmStatusEntry 3 }
gdsl2AlmStatusThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm Threshold Value "
::= { gdsl2AlmStatusEntry 4 }
gdsl2AlmStatusState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { gdsl2AlmStatusEntry 5 }
gdsl2AlmStatusCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { gdsl2AlmStatusEntry 6 }
gdsl2AlmStatusEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { gdsl2AlmStatusEntry 7 }
--
-- Gdsl2 Status Config Table
--
gdsl2StatusConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2StatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Gdsl Status Config Configuration "
::= { gdsl2-card 11 }
gdsl2StatusConfigEntry OBJECT-TYPE
SYNTAX Gdsl2StatusConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2StatusConfigTable 1 }
Gdsl2StatusConfigTableEntry ::= SEQUENCE {
gdsl2DS1SYNC INTEGER,
gdsl2DS1TxAIS INTEGER,
gdsl2DS1TxRAI INTEGER,
gdsl2DS1RxAIS INTEGER,
gdsl2DS1RxRAI INTEGER,
gdsl2DS1LOS INTEGER,
gdsl2DS1LOF INTEGER,
gdsl2dteDSR INTEGER,
gdsl2dteCTS INTEGER,
gdsl2dteDCD INTEGER,
gdsl2dteDTR INTEGER,
gdsl2dteRTS INTEGER,
gdsl2PortCAS INTEGER,
gdsl2LAN1Status INTEGER,
gdsl2WAN1Status INTEGER
}
gdsl2DS1SYNC OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line status."
::= { gdsl2StatusConfigEntry 1 }
gdsl2DS1TxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gshdsl DS1 line Tx Alarm Indication Signal."
::= { gdsl2StatusConfigEntry 2 }
gdsl2DS1TxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Tx Remote Alarm Indication."
::= { gdsl2StatusConfigEntry 3 }
gdsl2DS1RxAIS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Rx Alarm Indication Signal."
::= { gdsl2StatusConfigEntry 4 }
gdsl2DS1RxRAI OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line Rx Remote Alarm Indication."
::= { gdsl2StatusConfigEntry 5 }
gdsl2DS1LOS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line LOS Status."
::= { gdsl2StatusConfigEntry 6 }
gdsl2DS1LOF OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl DS1 line LOF Status."
::= { gdsl2StatusConfigEntry 7 }
gdsl2dteDSR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DSR Status."
::= { gdsl2StatusConfigEntry 8 }
gdsl2dteCTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line CTS Status."
::= { gdsl2StatusConfigEntry 9 }
gdsl2dteDCD OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DCD Status."
::= { gdsl2StatusConfigEntry 10 }
gdsl2dteDTR OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line DTR Status."
::= { gdsl2StatusConfigEntry 11 }
gdsl2dteRTS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl dte line RTS Status."
::= { gdsl2StatusConfigEntry 12 }
gdsl2PortCAS OBJECT-TYPE
SYNTAX INTEGER {
loss(1),
sync(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Gshdsl CAS Status."
::= { gdsl2StatusConfigEntry 13 }
gdsl2LAN1Status OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LAN1 Status."
::= { gdsl2StatusConfigEntry 14 }
gdsl2WAN1Status OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" WAN1 Status."
::= { gdsl2StatusConfigEntry 15 }
--
-- GDSL2 Info Table
--
gdsl2InfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: gdsl2InfoUnitIndex "
::= { gdsl2-card 12 }
gdsl2InfoEntry OBJECT-TYPE
SYNTAX Gdsl2InfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2LoopNum }
::= { gdsl2InfoTable 1 }
Gdsl2InfoEntry ::= SEQUENCE {
gdsl2LoopNum INTEGER,
gdsl2MasterNoiseMarginString DisplayString (SIZE(0..80)),
gdsl2MasterMaxNMRString DisplayString (SIZE(0..80)),
gdsl2MasterMinNMRString DisplayString (SIZE(0..80)),
gdsl2SlaveNoiseMarginString DisplayString (SIZE(0..80)),
gdsl2SlaveMaxNMRString DisplayString (SIZE(0..80)),
gdsl2SlaveMinNMRString DisplayString (SIZE(0..80))
}
gdsl2LoopNum OBJECT-TYPE
SYNTAX INTEGER {
loop-1(1),
loop-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Loop-1 or Loop-2"
::= { gdsl2InfoEntry 2 }
gdsl2MasterNoiseMarginString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Noise Margin String"
::= { gdsl2InfoEntry 3 }
gdsl2MasterMaxNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max Noise Margin String"
::= { gdsl2InfoEntry 4 }
gdsl2MasterMinNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Min Margin String"
::= { gdsl2InfoEntry 5 }
gdsl2SlaveNoiseMarginString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Noise Margin String"
::= { gdsl2InfoEntry 6 }
gdsl2SlaveMaxNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Max Noise Margin String"
::= { gdsl2InfoEntry 7 }
gdsl2SlaveMinNMRString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Min Margin String"
::= { gdsl2InfoEntry 8 }
--
-- Command Control Table
--
gdsl2CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { gdsl2-card 13 }
gdsl2CommandControlEntry OBJECT-TYPE
SYNTAX Gdsl2CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2CommandControlTable 1 }
Gdsl2CommandControlEntry ::= SEQUENCE {
gdsl2ClearAlarmQueue INTEGER,
gdsl2ClearPerformance INTEGER,
gdsl2ClearAlarmHistory INTEGER,
gdsl2UnitReset INTEGER,
gdsl2UnitLoadDefault INTEGER,
gdsl2FarEndReset INTEGER,
gdsl2CardMode INTEGER
}
gdsl2ClearAlarmQueue OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm Queue "
::= { gdsl2CommandControlEntry 2 }
gdsl2ClearPerformance OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear User Performance"
::= { gdsl2CommandControlEntry 3 }
gdsl2ClearAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm History"
::= { gdsl2CommandControlEntry 4 }
gdsl2UnitReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset G.SHDSL-2"
::= { gdsl2CommandControlEntry 5 }
gdsl2UnitLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default G.SHDSL-2"
::= { gdsl2CommandControlEntry 6 }
gdsl2FarEndReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Far End System"
::= { gdsl2CommandControlEntry 7 }
gdsl2CardMode OBJECT-TYPE
SYNTAX INTEGER {
e1Mode(1),
t1Mode(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Set card to E1 or T1 mode, will reset card"
::= { gdsl2CommandControlEntry 8 }
--
-- SYSTEM Information Table
--
gdsl2SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { gdsl2-card 14 }
gdsl2SystemInformationEntry OBJECT-TYPE
SYNTAX Gdsl2SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { gdsl2Index }
::= { gdsl2SystemInformationTable 1 }
Gdsl2SystemInformationEntry ::= SEQUENCE {
gdsl2SoftwareVersion DisplayString,
gdsl2HardwareVersion DisplayString
}
gdsl2SoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-2 Software Version"
::= { gdsl2SystemInformationEntry 2 }
gdsl2HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-2 Hardware Version"
::= { gdsl2SystemInformationEntry 3 }
--
-- G.SHDSL-2 Customer Information Table
--
gdsl2CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { gdsl2-card 99 }
gdsl2CustomerInfoEntry OBJECT-TYPE
SYNTAX Gdsl2CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { gdsl2CISlotIndex , gdsl2CIPortIndex }
::= { gdsl2CustomerInfoTable 1 }
Gdsl2CustomerInfoEntry ::= SEQUENCE {
gdsl2CISlotIndex LargeSlotIndex,
gdsl2CIPortIndex INTEGER,
gdsl2CICustomerInfo DisplayString (SIZE(0..64))
}
gdsl2CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2CustomerInfoEntry 1 }
gdsl2CIPortIndex OBJECT-TYPE
SYNTAX INTEGER {
port-1(1),
port-3(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { gdsl2CustomerInfoEntry 2 }
gdsl2CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { gdsl2CustomerInfoEntry 3 }
--
-- Daughter Card Information Table
--
gdsl2DaughterCardInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2DaughterCardInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Daughter Card Information table."
::= { gdsl2-card 15 }
gdsl2DaughterCardInfoEntry OBJECT-TYPE
SYNTAX Gdsl2DaughterCardInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the daughter card information table."
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2DaughterCardInfoTable 1 }
Gdsl2DaughterCardInfoEntry ::= SEQUENCE {
gdsl2DaughterCard INTEGER
}
gdsl2DaughterCard OBJECT-TYPE
SYNTAX INTEGER {
no-daughter-card(1),
sealing-current-single(2),
sealing-current-daul(3),
line-power-single(4),
line-power-daul(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" G.SHDSL-2 Daughter Card "
::= { gdsl2DaughterCardInfoEntry 2 }
--
-- GDSL2 ADVANCE SYSTEM Table
--
gdsl2AdvanceSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2AdvanceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system control table."
::= { gdsl2-card 16 }
gdsl2AdvanceSystemEntry OBJECT-TYPE
SYNTAX Gdsl2AdvanceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Advance system table."
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2SysHTUIndex }
::= { gdsl2AdvanceSystemTable 1 }
Gdsl2AdvanceSystemEntry ::= SEQUENCE {
gdsl2AnnexType INTEGER,
gdsl2ClockMode INTEGER,
gdsl2PSDMask INTEGER,
gdsl2PBOMode INTEGER
}
gdsl2AnnexType OBJECT-TYPE
SYNTAX INTEGER {
type-A(1),
type-B(2),
not-support(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.SHDSL Annex Type"
::= { gdsl2AdvanceSystemEntry 4 }
gdsl2ClockMode OBJECT-TYPE
SYNTAX INTEGER {
plesiosynchronous(1),
synchronous(2),
hybrid(3),
not-support(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL Clock Mode"
::= { gdsl2AdvanceSystemEntry 5 }
gdsl2PSDMask OBJECT-TYPE
SYNTAX INTEGER {
symmetric(1),
asymmetric(2),
not-support(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL PSD Mask"
::= { gdsl2AdvanceSystemEntry 6 }
gdsl2PBOMode OBJECT-TYPE
SYNTAX INTEGER {
automatic(1),
pbo-0-db(2),
pbo-1-db(3),
pbo-2-db(4),
pbo-3-db(5),
pbo-4-db(6),
pbo-5-db(7),
pbo-6-db(8),
pbo-7-db(9),
pbo-8-db(10),
pbo-9-db(11),
pbo-10-db(12),
pbo-11-db(13),
pbo-12-db(14),
pbo-13-db(15),
pbo-14-db(16),
pbo-15-db(17),
pbo-16-db(18),
pbo-17-db(19),
pbo-18-db(20),
pbo-19-db(21),
pbo-20-db(22),
pbo-21-db(23),
pbo-22-db(24),
pbo-23-db(25),
pbo-24-db(26),
pbo-25-db(27),
pbo-26-db(28),
pbo-27-db(29),
pbo-28-db(30),
pbo-29-db(31),
pbo-30-db(32),
pbo-31-db(33),
not-support(34)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" G.SHDSL PBO Mode"
::= { gdsl2AdvanceSystemEntry 7 }
--
-- GDSL2 Remote Link Identification Table
--
gdsl2RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The G.SHDSL Remote Link Identification Table."
::= { gdsl2-card 17 }
gdsl2RemoteLinkIDEntry OBJECT-TYPE
SYNTAX Gdsl2RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the G.SHDSL Remote Link Identification table."
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2RemoteLinkIDTable 1 }
Gdsl2RemoteLinkIDEntry ::= SEQUENCE {
gdsl2RemoteLinkIDType INTEGER,
gdsl2RemoteLinkIDRack INTEGER,
gdsl2RemoteLinkIDSlotNumber INTEGER,
gdsl2RemoteLinkIDPort INTEGER,
gdsl2RemoteLinkIDSerialNumber INTEGER
}
gdsl2RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of remote site."
::= { gdsl2RemoteLinkIDEntry 3 }
gdsl2RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { gdsl2RemoteLinkIDEntry 4 }
gdsl2RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { gdsl2RemoteLinkIDEntry 5 }
gdsl2RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { gdsl2RemoteLinkIDEntry 6 }
gdsl2RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { gdsl2RemoteLinkIDEntry 7 }
--
-- Seven Days Performance Table
--
gdsl2SevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { gdsl2-card 18 }
gdsl2SevenDaysPerfEntry OBJECT-TYPE
SYNTAX Gdsl2SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance entry"
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2DaysPerfTypeIndex ,
gdsl2DaysIndex }
::= { gdsl2SevenDaysPerfTable 1 }
Gdsl2SevenDaysPerfEntry ::= SEQUENCE {
gdsl2DaysPerfTypeIndex INTEGER,
gdsl2DaysIndex INTEGER (1..7),
gdsl2DateStrIndex DisplayString (SIZE (0..255) ),
gdsl2SevenDaysPerfES INTEGER,
gdsl2SevenDaysPerfSES INTEGER,
gdsl2SevenDaysPerfUAS INTEGER
}
gdsl2DaysPerfTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
master-loop-1(1),
master-loop-2(2),
master-ds1(3),
slave-loop-1(4),
slave-loop-2(5),
slave-ds1(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Performance Type"
::= { gdsl2SevenDaysPerfEntry 3 }
gdsl2DaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { gdsl2SevenDaysPerfEntry 4 }
gdsl2DateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { gdsl2SevenDaysPerfEntry 5 }
gdsl2SevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { gdsl2SevenDaysPerfEntry 6 }
gdsl2SevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { gdsl2SevenDaysPerfEntry 7 }
gdsl2SevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { gdsl2SevenDaysPerfEntry 8 }
--
-- GDSL2 Remote Fractional TABLE
--
gdsl2RemoteFracTable OBJECT IDENTIFIER ::= { gdsl2-card 19 }
--
-- GDSL2 Remote Fractional Config TABLE
--
gdsl2RemoteFracConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemoteFracConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Fractional Config Table"
::= { gdsl2RemoteFracTable 1 }
gdsl2RemoteFracConfigEntry OBJECT-TYPE
SYNTAX Gdsl2RemoteFracConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Fractional Config Entry "
INDEX { gdsl2Index ,
gdsl2PortIndex ,
gdsl2RemoteFracNumber }
::= { gdsl2RemoteFracConfigTable 1 }
Gdsl2RemoteFracConfigEntry ::= SEQUENCE {
gdsl2RemoteFracNumber INTEGER,
gdsl2RemoteFracIfIndex INTEGER
}
gdsl2RemoteFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Fractional Number "
::= { gdsl2RemoteFracConfigEntry 3 }
gdsl2RemoteFracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-x(3),
chan-dte(4),
chan-ethernet(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Fractional IfIndex"
::= { gdsl2RemoteFracConfigEntry 4 }
--
-- GDSL2 Set Remote Fractional TABLE
--
gdsl2SetRemoteFracTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2SetRemoteFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Set Remote Fractional Table"
::= { gdsl2RemoteFracTable 2 }
gdsl2SetRemoteFracEntry OBJECT-TYPE
SYNTAX Gdsl2SetRemoteFracEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Set Remote Fractional Entry "
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2SetRemoteFracTable 1 }
Gdsl2SetRemoteFracEntry ::= SEQUENCE {
gdsl2StartFracNumber INTEGER,
gdsl2FracNumbers INTEGER,
gdsl2E1T1ClearStartFracNumber INTEGER,
gdsl2SetFracIfIndex INTEGER
}
gdsl2StartFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Start Fractional Number "
::= { gdsl2SetRemoteFracEntry 3 }
gdsl2FracNumbers OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of Fractional"
::= { gdsl2SetRemoteFracEntry 4 }
gdsl2E1T1ClearStartFracNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote E1/T1 Clear Start Fractional Number"
::= { gdsl2SetRemoteFracEntry 5 }
gdsl2SetFracIfIndex OBJECT-TYPE
SYNTAX INTEGER {
chan-idle(1),
chan-ds1(2),
chan-x(3),
chan-dte(4),
chan-ethernet(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Fractional IfIndex"
::= { gdsl2SetRemoteFracEntry 6 }
--
-- Remote Bert Control Table
--
gdsl2RemoteBertTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemoteBertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { gdsl2-card 20 }
gdsl2RemoteBertEntry OBJECT-TYPE
SYNTAX Gdsl2RemoteBertEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { gdsl2Index ,
gdsl2PortIndex }
::= { gdsl2RemoteBertTable 1 }
Gdsl2RemoteBertEntry ::= SEQUENCE {
gdsl2RemBertPatternType INTEGER,
gdsl2RemBertTestChannel INTEGER,
gdsl2RemBertTestControl INTEGER,
gdsl2RemBertStatus INTEGER,
gdsl2RemBertErrSecond INTEGER,
gdsl2RemBertErrCounter INTEGER,
gdsl2RemBertElapsedSecond INTEGER,
gdsl2RemBertUnsyncSecond INTEGER
}
gdsl2RemBertPatternType OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
-- off(1),
bert-2-15-1(2),
bert-qrss(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Pattern Type"
::= { gdsl2RemoteBertEntry 3 }
gdsl2RemBertTestChannel OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
full(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Test Channel Type"
::= { gdsl2RemoteBertEntry 4 }
gdsl2RemBertTestControl OBJECT-TYPE
SYNTAX INTEGER {
un-support(0),
disable(1),
enable(2),
reset(3),
insert-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Test Control"
::= { gdsl2RemoteBertEntry 5 }
gdsl2RemBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-unsync(1),
bert-sync(2),
bert-not-active(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Status"
::= { gdsl2RemoteBertEntry 6 }
gdsl2RemBertErrSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Error Seconds"
::= { gdsl2RemoteBertEntry 7 }
gdsl2RemBertErrCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Error Counter"
::= { gdsl2RemoteBertEntry 8 }
gdsl2RemBertElapsedSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Elapsed Time"
::= { gdsl2RemoteBertEntry 9 }
gdsl2RemBertUnsyncSecond OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote BERT Unsync Time"
::= { gdsl2RemoteBertEntry 10 }
--
-- G.shdsl card Remote Router Table
--
gdsl2RouterConfig OBJECT IDENTIFIER ::= { gdsl2-card 21 }
--
-- G.shdsl card remote NI Control Table
--
gdsl2RtrNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Table"
::= { gdsl2RouterConfig 1 }
gdsl2RouterNiControlEntry OBJECT-TYPE
SYNTAX Gdsl2RtrNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router NI Configuration Control Entry"
INDEX { gdsl2RtrNiUnitIndex ,
gdsl2RtrNiPortIndex ,
gdsl2RtrNiIndex }
::= { gdsl2RtrNiControlTable 1 }
Gdsl2RtrNiControlEntry ::= SEQUENCE {
gdsl2RtrNiUnitIndex LargeSlotIndex,
gdsl2RtrNiPortIndex G2PortID,
gdsl2RtrNiIndex INTEGER,
gdsl2RtrIPAddr IpAddress,
gdsl2RtrSubnetMask IpAddress,
gdsl2RtrFrame INTEGER,
gdsl2RtrRIP1 INTEGER,
gdsl2RtrRIP2 INTEGER,
gdsl2RtrMode INTEGER
}
gdsl2RtrNiUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RouterNiControlEntry 1 }
gdsl2RtrNiPortIndex OBJECT-TYPE
SYNTAX G2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1/3, total 2 ports."
::= { gdsl2RouterNiControlEntry 2 }
gdsl2RtrNiIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Ni index"
::= { gdsl2RouterNiControlEntry 3 }
gdsl2RtrIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR IP Address"
::= { gdsl2RouterNiControlEntry 4 }
gdsl2RtrSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR net mask"
::= { gdsl2RouterNiControlEntry 5 }
gdsl2RtrFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
ethernet(4),
na(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Layer2 frame"
::= { gdsl2RouterNiControlEntry 6 }
gdsl2RtrRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP1"
::= { gdsl2RouterNiControlEntry 7 }
gdsl2RtrRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR RIP2"
::= { gdsl2RouterNiControlEntry 8 }
gdsl2RtrMode OBJECT-TYPE
SYNTAX INTEGER {
router(1),
bridge(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR mode"
::= { gdsl2RouterNiControlEntry 9 }
--
-- G.shdsl card remote Route Table
--
gdsl2RtrRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Table"
::= { gdsl2RouterConfig 2 }
gdsl2RouterRouteControlEntry OBJECT-TYPE
SYNTAX Gdsl2RtrRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Route Control Entry"
INDEX { gdsl2RtrRUnitIndex ,
gdsl2RtrRPortIndex ,
gdsl2RtrEntry }
::= { gdsl2RtrRouteControlTable 1 }
Gdsl2RtrRouteControlEntry ::= SEQUENCE {
gdsl2RtrRUnitIndex LargeSlotIndex,
gdsl2RtrRPortIndex G2PortID,
gdsl2RtrEntry INTEGER (1..16),
gdsl2RtrNetAddr IpAddress,
gdsl2RtrNetMask IpAddress,
gdsl2RtrGatewayAddr IpAddress,
gdsl2RtrNIAddr IpAddress,
gdsl2RtrMetric INTEGER,
gdsl2RtrInterface INTEGER
}
gdsl2RtrRUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RouterRouteControlEntry 1 }
gdsl2RtrRPortIndex OBJECT-TYPE
SYNTAX G2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1/3, total 2 ports."
::= { gdsl2RouterRouteControlEntry 2 }
gdsl2RtrEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Router Route Entry"
::= { gdsl2RouterRouteControlEntry 3 }
gdsl2RtrNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net Address"
::= { gdsl2RouterRouteControlEntry 4 }
gdsl2RtrNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route net mask"
::= { gdsl2RouterRouteControlEntry 5 }
gdsl2RtrGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route gateway Address"
::= { gdsl2RouterRouteControlEntry 6 }
gdsl2RtrNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR route NI Address"
::= { gdsl2RouterRouteControlEntry 7 }
gdsl2RtrMetric OBJECT-TYPE
SYNTAX INTEGER {
na(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Route metric"
::= { gdsl2RouterRouteControlEntry 8 }
gdsl2RtrInterface OBJECT-TYPE
SYNTAX INTEGER {
na(1),
lan(2),
wan(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RTR Router Interface"
::= { gdsl2RouterRouteControlEntry 9 }
--
-- G.shdsl card remote Router Command
--
gdsl2RtrCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Table"
::= { gdsl2RouterConfig 3 }
gdsl2RtrCommandEntry OBJECT-TYPE
SYNTAX Gdsl2RtrCmdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Command Entry"
INDEX { gdsl2RtrCmdUnitIndex ,
gdsl2RtrCmdPortIndex }
::= { gdsl2RtrCommandTable 1 }
Gdsl2RtrCmdEntry ::= SEQUENCE {
gdsl2RtrCmdUnitIndex LargeSlotIndex,
gdsl2RtrCmdPortIndex G2PortID,
gdsl2RtrCommand INTEGER,
gdsl2CRCtransparency INTEGER
}
gdsl2RtrCmdUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RtrCommandEntry 1 }
gdsl2RtrCmdPortIndex OBJECT-TYPE
SYNTAX G2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1/3, total 2 ports."
::= { gdsl2RtrCommandEntry 2 }
gdsl2RtrCommand OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
load-default(2),
none(3),
re-get-map-cfg(11),
re-get-ni-cfg(12),
re-get-rtr-cfg(13),
re-get-crc-cfg(14),
re-get-all-cfg(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Router Command(reset or load-default)"
::= { gdsl2RtrCommandEntry 3 }
gdsl2CRCtransparency OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CRC transparency"
::= { gdsl2RtrCommandEntry 4 }
--
-- G.shdsl card remote Router Map
--
gdsl2RtrMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Table"
::= { gdsl2RouterConfig 4 }
gdsl2RtrMapEntry OBJECT-TYPE
SYNTAX Gdsl2RtrMappingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Router Map Entry"
INDEX { gdsl2RtrMapUnitIndex ,
gdsl2RtrMapPortIndex ,
gdsl2RtrMapTsIndex }
::= { gdsl2RtrMapTable 1 }
Gdsl2RtrMappingEntry ::= SEQUENCE {
gdsl2RtrMapUnitIndex LargeSlotIndex,
gdsl2RtrMapPortIndex G2PortID,
gdsl2RtrMapTsIndex TimeslotID,
gdsl2RtrCh INTEGER
}
gdsl2RtrMapUnitIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RtrMapEntry 1 }
gdsl2RtrMapPortIndex OBJECT-TYPE
SYNTAX G2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1/3, total 2 ports."
::= { gdsl2RtrMapEntry 2 }
gdsl2RtrMapTsIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Timeslot 1~32, total 32 timeslots."
::= { gdsl2RtrMapEntry 3 }
gdsl2RtrCh OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"channel map data"
::= { gdsl2RtrMapEntry 4 }
--
-- G.shdsl card remote Bridge Config
--
gdsl2RemoteBridgeConfig OBJECT IDENTIFIER ::= { gdsl2-card 22 }
-- G.shdsl card remote Bridge: config table
gdsl2RemBridgeTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Bridge Table"
::= { gdsl2RemoteBridgeConfig 1 }
gdsl2RemBridgeEntry OBJECT-TYPE
SYNTAX Gdsl2RemBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Bridge Entry"
INDEX { gdsl2RBSlotIndex ,
gdsl2RBPortIndex }
::= { gdsl2RemBridgeTable 1 }
Gdsl2RemBridgeEntry ::= SEQUENCE {
gdsl2RBSlotIndex LargeSlotIndex,
gdsl2RBPortIndex FourPortID,
gdsl2RemBrgAgeTime INTEGER (10..1000000),
gdsl2RemBrgCRC INTEGER,
gdsl2RemBrgLanSpeed INTEGER
-- gdsl2RemBrgLan2Speed INTEGER
}
gdsl2RBSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RemBridgeEntry 1 }
gdsl2RBPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl2RemBridgeEntry 2 }
gdsl2RemBrgAgeTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: Age time 10~1000000 seconds."
::= { gdsl2RemBridgeEntry 3 }
gdsl2RemBrgCRC OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: CRC"
::= { gdsl2RemBridgeEntry 4 }
gdsl2RemBrgLanSpeed OBJECT-TYPE
SYNTAX INTEGER {
no(0),
half-duplex-10M(1),
full-duplex-10M(2),
half-duplex-100M(3),
full-duplex-100M(4),
auto-negotiation(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Bridge: LAN1 speed"
::= { gdsl2RemBridgeEntry 5 }
-- gdsl2RemBrgLan2Speed OBJECT-TYPE
-- SYNTAX INTEGER {
-- no(0),
-- half-duplex-10M(1),
-- full-duplex-10M(2),
-- half-duplex-100M(3),
-- full-duplex-100M(4),
-- auto-negotiation(5)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Remote Bridge: LAN2 speed"
-- ::= { gdsl2RemBridgeEntry 6 }
-- G.shdsl card remote VLAN: VLAN State Table
gdsl2RemVlanStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemVlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN State Table"
::= { gdsl2RemoteBridgeConfig 2 }
gdsl2RemVlanStateEntry OBJECT-TYPE
SYNTAX Gdsl2RemVlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN State Entry"
INDEX { gdsl2RVSSlotIndex ,
gdsl2RVSPortIndex }
::= { gdsl2RemVlanStateTable 1 }
Gdsl2RemVlanStateEntry ::= SEQUENCE {
gdsl2RVSSlotIndex LargeSlotIndex,
gdsl2RVSPortIndex FourPortID,
gdsl2RemVlanEnable INTEGER,
gdsl2RemVlanMgmtVID INTEGER (1..4095),
gdsl2RemVlanRegenCRC INTEGER
}
gdsl2RVSSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RemVlanStateEntry 1 }
gdsl2RVSPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl2RemVlanStateEntry 2 }
gdsl2RemVlanEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: disable or enable"
::= { gdsl2RemVlanStateEntry 3 }
gdsl2RemVlanMgmtVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Magement VID"
::= { gdsl2RemVlanStateEntry 4 }
gdsl2RemVlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: regenate CRC"
::= { gdsl2RemVlanStateEntry 5 }
-- G.shdsl card remote Bridge: VLAN Control Table
gdsl2RemVlanControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemVlanControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Control Table"
::= { gdsl2RemoteBridgeConfig 3 }
gdsl2RemVlanControlEntry OBJECT-TYPE
SYNTAX Gdsl2RemVlanControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Control Entry"
INDEX { gdsl2RVCSlotIndex ,
gdsl2RVCPortIndex }
::= { gdsl2RemVlanControlTable 1 }
Gdsl2RemVlanControlEntry ::= SEQUENCE {
gdsl2RVCSlotIndex LargeSlotIndex,
gdsl2RVCPortIndex FourPortID,
gdsl2RemVlanVID INTEGER (1..4095),
gdsl2RemVlanTAG INTEGER,
gdsl2RemVlanMember INTEGER,
gdsl2RemVlanCommand INTEGER,
gdsl2RemVlanResponse INTEGER
}
gdsl2RVCSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RemVlanControlEntry 1 }
gdsl2RVCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl2RemVlanControlEntry 2 }
gdsl2RemVlanVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl2RemVlanControlEntry 4 }
gdsl2RemVlanTAG OBJECT-TYPE
SYNTAX INTEGER {
untag(1),
tag(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: UNTAG or TAG"
::= { gdsl2RemVlanControlEntry 5 }
gdsl2RemVlanMember OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Member is LAN1 or WAN1"
::= { gdsl2RemVlanControlEntry 6 }
gdsl2RemVlanCommand OBJECT-TYPE
SYNTAX INTEGER {
create-vid(1),
add-member(2),
deactive-vid(3),
remove-member(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: command"
::= { gdsl2RemVlanControlEntry 11 }
gdsl2RemVlanResponse OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
vid-created-before(2),
vid-not-created-before(3),
not-empty(4),
no-response(11),
not-available(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: Set response"
::= { gdsl2RemVlanControlEntry 12 }
-- G.shdsl card remote Bridge: VLAN List Table
gdsl2RemVlanListTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemVlanListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN List Table"
::= { gdsl2RemoteBridgeConfig 4 }
gdsl2RemVlanListEntry OBJECT-TYPE
SYNTAX Gdsl2RemVlanListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN List Entry"
INDEX { gdsl2RVLSlotIndex ,
gdsl2RVLPortIndex ,
gdsl2RVLVLanIndex }
::= { gdsl2RemVlanListTable 1 }
Gdsl2RemVlanListEntry ::= SEQUENCE {
gdsl2RVLSlotIndex LargeSlotIndex,
gdsl2RVLPortIndex FourPortID,
gdsl2RVLVLanIndex INTEGER,
gdsl2RVLVlanVID INTEGER (1..4095),
gdsl2RVLVlanTAGmember DisplayString,
gdsl2RVLVlanUNTAGmember DisplayString
}
gdsl2RVLSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RemVlanListEntry 1 }
gdsl2RVLPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl2RemVlanListEntry 2 }
gdsl2RVLVLanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VLAN list index"
::= { gdsl2RemVlanListEntry 3 }
gdsl2RVLVlanVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl2RemVlanListEntry 4 }
gdsl2RVLVlanTAGmember OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: TAG member"
::= { gdsl2RemVlanListEntry 5 }
gdsl2RVLVlanUNTAGmember OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: UNTAG member"
::= { gdsl2RemVlanListEntry 6 }
-- G.shdsl card remote Bridge: VLAN Port Table
gdsl2RemVlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Gdsl2RemVlanPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Port Table"
::= { gdsl2RemoteBridgeConfig 5 }
gdsl2RemVlanPortEntry OBJECT-TYPE
SYNTAX Gdsl2RemVlanPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote VLAN Port Entry"
INDEX { gdsl2RVPSlotIndex ,
gdsl2RVPPortIndex ,
gdsl2RVPVPIndex }
::= { gdsl2RemVlanPortTable 1 }
Gdsl2RemVlanPortEntry ::= SEQUENCE {
gdsl2RVPSlotIndex LargeSlotIndex,
gdsl2RVPPortIndex FourPortID,
gdsl2RVPVPIndex INTEGER,
gdsl2RVPVlanPVID INTEGER (1..4095),
gdsl2RVPVlanFrameType INTEGER,
gdsl2RVPVlanIngressFilter INTEGER,
gdsl2RVPSetResponse INTEGER
}
gdsl2RVPSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { gdsl2RemVlanPortEntry 1 }
gdsl2RVPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~4, total 4 ports."
::= { gdsl2RemVlanPortEntry 2 }
gdsl2RVPVPIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
wan1(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VLAN Port index"
::= { gdsl2RemVlanPortEntry 3 }
gdsl2RVPVlanPVID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: VLAN ID"
::= { gdsl2RemVlanPortEntry 4 }
gdsl2RVPVlanFrameType OBJECT-TYPE
SYNTAX INTEGER {
all(1),
tag-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Frame Type"
::= { gdsl2RemVlanPortEntry 5 }
gdsl2RVPVlanIngressFilter OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote VLAN: Ingress Filter"
::= { gdsl2RemVlanPortEntry 6 }
gdsl2RVPSetResponse OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
vid-not-created-before(3),
no-response(11),
not-available(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote VLAN: Set response"
::= { gdsl2RemVlanPortEntry 7 }
gdsl2TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 2GH"
::= { gdsl2-card 100 }
--======================================================================--
--======================================================================--
-- mini quad-e1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
mqe1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { mqe1-card 1 }
mqe1LineControlEntry OBJECT-TYPE
SYNTAX MQE1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1LineControlTable 1 }
MQE1LineControlEntry ::= SEQUENCE {
mqe1Index SmallSlotIndex,
mqe1PortIndex FourPortID,
mqe1LineFrame INTEGER,
mqe1LineCoding INTEGER,
mqe1Interface INTEGER,
mqe1FDL INTEGER,
mqe1FDLSabit INTEGER,
mqe1AIS INTEGER,
mqe1RAI INTEGER,
mqe1CRC INTEGER,
mqe1IdleCode INTEGER,
mqe1CASMode INTEGER,
mqe1SignallingMode INTEGER,
mqe1CGA INTEGER,
mqe1OutOfService INTEGER,
mqe1Protect INTEGER,
mqe1Master INTEGER
}
mqe1Index OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { mqe1LineControlEntry 1 }
mqe1PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqe1LineControlEntry 2 }
mqe1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { mqe1LineControlEntry 3 }
mqe1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { mqe1LineControlEntry 4 }
mqe1Interface OBJECT-TYPE
SYNTAX INTEGER {
twisted-pair(1),
coaxial-cable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that MQE1 line use 75/120 Ohm Cable."
::= { mqe1LineControlEntry 5 }
mqe1FDL OBJECT-TYPE
SYNTAX INTEGER {
fdl(1),
off(2),
hdlc(3),
ssm(4)
-- ssm-hdlc(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQE1 Facility Data Link ON/OFF"
::= { mqe1LineControlEntry 6 }
mqe1FDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
sa4-5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQE1 Facility Data Link use Sax bit"
::= { mqe1LineControlEntry 7 }
mqe1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQE1 line Alarm Indication Signal."
::= { mqe1LineControlEntry 8 }
mqe1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { mqe1LineControlEntry 9 }
mqe1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MQE1 Cycle Redundancy Check ON/OFF"
::= { mqe1LineControlEntry 10 }
mqe1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { mqe1LineControlEntry 11 }
mqe1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { mqe1LineControlEntry 12 }
mqe1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
cd01(2) --//RIKER2021 SilverCreek
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS or CD01"
::= { mqe1LineControlEntry 13 }
mqe1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { mqe1LineControlEntry 14 }
mqe1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { mqe1LineControlEntry 15 }
mqe1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { mqe1LineControlEntry 16 }
mqe1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { mqe1LineControlEntry 17 }
--
-- User Current Performance Table
--
mqe1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { mqe1-card 2 }
mqe1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX MQE1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1UserCurrentPerfTable 1 }
MQE1UserCurrentPerfEntry ::= SEQUENCE {
mqe1UserCurrentPerfES INTEGER,
mqe1UserCurrentPerfSES INTEGER,
mqe1UserCurrentPerfBES INTEGER,
mqe1UserCurrentPerfUAS INTEGER,
mqe1UserCurrentPerfCSS INTEGER,
mqe1UserCurrentPerfBPV INTEGER,
mqe1UserCurrentPerfDMs INTEGER,
mqe1UserCurr15MinTimeElapsed INTEGER,
mqe1UserValid15MinInterval INTEGER
}
mqe1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1UserCurrentPerfEntry 2 }
mqe1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1UserCurrentPerfEntry 3 }
mqe1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1UserCurrentPerfEntry 4 }
mqe1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1UserCurrentPerfEntry 5 }
mqe1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { mqe1UserCurrentPerfEntry 6 }
mqe1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1UserCurrentPerfEntry 7 }
mqe1UserCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1UserCurrentPerfEntry 8 }
mqe1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { mqe1UserCurrentPerfEntry 11 }
mqe1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { mqe1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
mqe1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { mqe1-card 3 }
mqe1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX MQE1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1UserIntervalPerfNumber }
::= { mqe1UserIntervalPerfTable 1 }
MQE1UserIntervalPerfEntry ::= SEQUENCE {
mqe1UserIntervalPerfNumber INTEGER (1..96),
mqe1UserIntervalPerfES INTEGER,
mqe1UserIntervalPerfSES INTEGER,
mqe1UserIntervalPerfBES INTEGER,
mqe1UserIntervalPerfUAS INTEGER,
mqe1UserIntervalPerfCSS INTEGER,
mqe1UserIntervalPerfBPV INTEGER,
mqe1UserIntervalPerfDMs INTEGER
}
mqe1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { mqe1UserIntervalPerfEntry 2 }
mqe1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1UserIntervalPerfEntry 3 }
mqe1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1UserIntervalPerfEntry 4 }
mqe1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1UserIntervalPerfEntry 5 }
mqe1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1UserIntervalPerfEntry 6 }
mqe1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1UserIntervalPerfEntry 7 }
mqe1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1UserIntervalPerfEntry 8 }
mqe1UserIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
mqe1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { mqe1-card 4 }
mqe1UserTotalPerfEntry OBJECT-TYPE
SYNTAX MQE1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1UserTotalPerfTable 1 }
MQE1UserTotalPerfEntry ::= SEQUENCE {
mqe1UserTotalPerfES INTEGER,
mqe1UserTotalPerfSES INTEGER,
mqe1UserTotalPerfBES INTEGER,
mqe1UserTotalPerfUAS INTEGER,
mqe1UserTotalPerfCSS INTEGER,
mqe1UserTotalPerfBPV INTEGER,
mqe1UserTotalPerfDMs INTEGER
}
mqe1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1UserTotalPerfEntry 2 }
mqe1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1UserTotalPerfEntry 3 }
mqe1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1UserTotalPerfEntry 4 }
mqe1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1UserTotalPerfEntry 5 }
mqe1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1UserTotalPerfEntry 6 }
mqe1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1UserTotalPerfEntry 7 }
mqe1UserTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
mqe1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { mqe1-card 5 }
mqe1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX MQE1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1UserDaysIndex }
::= { mqe1UserSevenDaysPerfTable 1 }
MQE1UserSevenDaysPerfEntry ::= SEQUENCE {
mqe1UserDaysIndex INTEGER (1..7),
mqe1UserDateStrIndex DisplayString (SIZE (0..255) ),
mqe1UserSevenDaysPerfES INTEGER,
mqe1UserSevenDaysPerfSES INTEGER,
mqe1UserSevenDaysPerfBES INTEGER,
mqe1UserSevenDaysPerfUAS INTEGER,
mqe1UserSevenDaysPerfCSS INTEGER,
mqe1UserSevenDaysPerfDMs INTEGER,
mqe1UserSevenDaysPerfBPV INTEGER
}
mqe1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { mqe1UserSevenDaysPerfEntry 2 }
mqe1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { mqe1UserSevenDaysPerfEntry 3 }
mqe1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1UserSevenDaysPerfEntry 4 }
mqe1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1UserSevenDaysPerfEntry 5 }
mqe1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1UserSevenDaysPerfEntry 6 }
mqe1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1UserSevenDaysPerfEntry 7 }
mqe1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1UserSevenDaysPerfEntry 8 }
mqe1UserSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1UserSevenDaysPerfEntry 9 }
mqe1UserSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1UserSevenDaysPerfEntry 10 }
--
-- Line Current Performance Table
--
mqe1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { mqe1-card 10 }
mqe1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX MQE1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1LineCurrentPerfTable 1 }
MQE1LineCurrentPerfEntry ::= SEQUENCE {
mqe1LineCurrentPerfES INTEGER,
mqe1LineCurrentPerfSES INTEGER,
mqe1LineCurrentPerfBES INTEGER,
mqe1LineCurrentPerfUAS INTEGER,
mqe1LineCurrentPerfCSS INTEGER,
mqe1LineCurrentPerfBPV INTEGER,
mqe1LineCurrentPerfDMs INTEGER,
mqe1LineCurr15MinTimeElapsed INTEGER,
mqe1LineValid15MinInterval INTEGER
}
mqe1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { mqe1LineCurrentPerfEntry 2 }
mqe1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1LineCurrentPerfEntry 3 }
mqe1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1LineCurrentPerfEntry 4 }
mqe1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1LineCurrentPerfEntry 5 }
mqe1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1LineCurrentPerfEntry 6 }
mqe1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1LineCurrentPerfEntry 7 }
mqe1LineCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1LineCurrentPerfEntry 8 }
mqe1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { mqe1LineCurrentPerfEntry 11 }
mqe1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { mqe1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
mqe1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { mqe1-card 11 }
mqe1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX MQE1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1LineIntervalPerfNumber }
::= { mqe1LineIntervalPerfTable 1 }
MQE1LineIntervalPerfEntry ::= SEQUENCE {
mqe1LineIntervalPerfNumber INTEGER (1..96),
mqe1LineIntervalPerfES INTEGER,
mqe1LineIntervalPerfSES INTEGER,
mqe1LineIntervalPerfBES INTEGER,
mqe1LineIntervalPerfUAS INTEGER,
mqe1LineIntervalPerfCSS INTEGER,
mqe1LineIntervalPerfBPV INTEGER,
mqe1LineIntervalPerfDMs INTEGER,
mqe1LineIntvAvailable INTEGER
}
mqe1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { mqe1LineIntervalPerfEntry 2 }
mqe1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1LineIntervalPerfEntry 3 }
mqe1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1LineIntervalPerfEntry 4 }
mqe1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1LineIntervalPerfEntry 5 }
mqe1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1LineIntervalPerfEntry 6 }
mqe1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1LineIntervalPerfEntry 7 }
mqe1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1LineIntervalPerfEntry 8 }
mqe1LineIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1LineIntervalPerfEntry 9 }
mqe1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { mqe1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
mqe1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { mqe1-card 12 }
mqe1LineTotalPerfEntry OBJECT-TYPE
SYNTAX MQE1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1LineTotalPerfTable 1 }
MQE1LineTotalPerfEntry ::= SEQUENCE {
mqe1LineTotalPerfES INTEGER,
mqe1LineTotalPerfSES INTEGER,
mqe1LineTotalPerfBES INTEGER,
mqe1LineTotalPerfUAS INTEGER,
mqe1LineTotalPerfCSS INTEGER,
mqe1LineTotalPerfBPV INTEGER,
mqe1LineTotalPerfDMs INTEGER
}
mqe1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1LineTotalPerfEntry 2 }
mqe1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1LineTotalPerfEntry 3 }
mqe1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1LineTotalPerfEntry 4 }
mqe1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1LineTotalPerfEntry 5 }
mqe1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1LineTotalPerfEntry 6 }
mqe1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1LineTotalPerfEntry 7 }
mqe1LineTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
mqe1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { mqe1-card 13 }
mqe1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX MQE1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1LineDaysIndex }
::= { mqe1LineSevenDaysPerfTable 1 }
MQE1LineSevenDaysPerfEntry ::= SEQUENCE {
mqe1LineDaysIndex INTEGER (1..7),
mqe1LineDateStrIndex DisplayString (SIZE (0..255) ),
mqe1LineSevenDaysPerfES INTEGER,
mqe1LineSevenDaysPerfSES INTEGER,
mqe1LineSevenDaysPerfBES INTEGER,
mqe1LineSevenDaysPerfUAS INTEGER,
mqe1LineSevenDaysPerfCSS INTEGER,
mqe1LineSevenDaysPerfDMs INTEGER,
mqe1LineSevenDaysPerfBPV INTEGER
}
mqe1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { mqe1LineSevenDaysPerfEntry 2 }
mqe1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { mqe1LineSevenDaysPerfEntry 3 }
mqe1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqe1LineSevenDaysPerfEntry 4 }
mqe1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqe1LineSevenDaysPerfEntry 5 }
mqe1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqe1LineSevenDaysPerfEntry 6 }
mqe1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqe1LineSevenDaysPerfEntry 7 }
mqe1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqe1LineSevenDaysPerfEntry 8 }
mqe1LineSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { mqe1LineSevenDaysPerfEntry 9 }
mqe1LineSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqe1LineSevenDaysPerfEntry 10 }
--
-- Alarm Queue Table
--
mqe1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { mqe1-card 14 }
mqe1AlarmQueueEntry OBJECT-TYPE
SYNTAX MQE1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1AlarmQueueIndex }
::= { mqe1AlarmQueueTable 1 }
MQE1AlarmQueueEntry ::= SEQUENCE {
mqe1AlarmQueueIndex INTEGER (1..40),
mqe1AlarmQueueString DisplayString (SIZE(0..255))
}
mqe1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { mqe1AlarmQueueEntry 2 }
mqe1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { mqe1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
mqe1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { mqe1-card 15 }
mqe1AlarmHistoryEntry OBJECT-TYPE
SYNTAX MQE1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { mqe1Index , mqe1PortIndex ,
mqe1AlarmHistoryIndex }
::= { mqe1AlarmHistoryTable 1 }
MQE1AlarmHistoryEntry ::= SEQUENCE {
mqe1AlarmHistoryIndex INTEGER,
mqe1Threshold INTEGER,
mqe1CurrentState INTEGER,
mqe1CurrentCount INTEGER,
mqe1Alarm AlarmSeverity
}
mqe1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
tpca(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { mqe1AlarmHistoryEntry 2 }
mqe1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { mqe1AlarmHistoryEntry 3 }
mqe1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { mqe1AlarmHistoryEntry 4 }
mqe1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { mqe1AlarmHistoryEntry 5 }
mqe1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { mqe1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
mqe1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { mqe1-card 16 }
mqe1LineAvailabilityEntry OBJECT-TYPE
SYNTAX MQE1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1LineAvailabilityTable 1 }
MQE1LineAvailabilityEntry ::= SEQUENCE {
mqe1AvailableSeconds DisplayString,
mqe1UnavailableSeconds DisplayString,
mqe1LineAvailability DisplayString
}
mqe1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { mqe1LineAvailabilityEntry 2 }
mqe1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { mqe1LineAvailabilityEntry 3 }
mqe1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { mqe1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
mqe1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqe1-card 17 }
mqe1AlarmControlEntry OBJECT-TYPE
SYNTAX MQE1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1AlarmControlTable 1 }
MQE1AlarmControlEntry ::= SEQUENCE {
mqe1RAI-Line AlarmSeverity,
mqe1AIS-Line AlarmSeverity,
mqe1LOS-Line AlarmSeverity,
mqe1LOF-Line AlarmSeverity,
mqe1BPV-Line AlarmSeverity,
mqe1ESS-Line AlarmSeverity,
mqe1UAS-Line AlarmSeverity,
mqe1CSS-Line AlarmSeverity,
mqe1TCPA AlarmSeverity
}
mqe1RAI-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { mqe1AlarmControlEntry 2 }
mqe1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { mqe1AlarmControlEntry 3 }
mqe1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { mqe1AlarmControlEntry 4 }
mqe1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { mqe1AlarmControlEntry 5 }
mqe1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { mqe1AlarmControlEntry 6 }
mqe1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { mqe1AlarmControlEntry 7 }
mqe1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { mqe1AlarmControlEntry 8 }
mqe1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { mqe1AlarmControlEntry 9 }
-- RIKER 2013 NFS-13000027
mqe1TCPA OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold Crossing Performance Alarm"
::= { mqe1AlarmControlEntry 10 }
--
-- Threshold Control Table
--
mqe1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqe1-card 18 }
mqe1ThresholdControlEntry OBJECT-TYPE
SYNTAX MQE1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1ThresholdControlTable 1 }
MQE1ThresholdControlEntry ::= SEQUENCE {
mqe1ThresholdBPV-Line INTEGER,
mqe1ThresholdESS-Line INTEGER,
mqe1ThresholdUAS-Line INTEGER,
mqe1ThresholdCSS-Line INTEGER,
mqe1ThresholdTCPA INTEGER
}
mqe1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line: 10exp-N"
::= { mqe1ThresholdControlEntry 2 }
mqe1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { mqe1ThresholdControlEntry 3 }
mqe1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { mqe1ThresholdControlEntry 4 }
mqe1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { mqe1ThresholdControlEntry 5 }
-- RIKER 2013 NFS-13000027
mqe1ThresholdTCPA OBJECT-TYPE
SYNTAX INTEGER (1..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of TCPA "
::= { mqe1ThresholdControlEntry 6 }
--
-- Line Diagnostic Control Table
--
mqe1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqe1-card 19 }
mqe1LineDiagControlEntry OBJECT-TYPE
SYNTAX MQE1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1LineDiagControlTable 1 }
MQE1LineDiagControlEntry ::= SEQUENCE {
mqe1LoopbackType INTEGER,
mqe1LoopbackStatus INTEGER,
mqe1PRBSControl INTEGER,
mqe1PRBSStatus INTEGER,
mqe1PRBSElapseSeconds INTEGER,
mqe1PRBSErrorSeconds INTEGER,
mqe1PRBSErrorCounts INTEGER,
mqe1InbandLoopbackPeriod INTEGER
}
mqe1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-PLB-Active(5),
remote-LLB-Active(6),
remote-PLB-Deactive(7),
remote-LLB-Deactive(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mqe1 Loopback Type"
::= { mqe1LineDiagControlEntry 2 }
mqe1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqe1 Loopback Status"
::= { mqe1LineDiagControlEntry 3 }
mqe1PRBSControl OBJECT-TYPE
SYNTAX INTEGER {
prbs-deactive(1),
prbs-active-full(2),
prbs-reset-error-count(3),
prbs-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mqe1 PRBS Control"
::= { mqe1LineDiagControlEntry 4 }
mqe1PRBSStatus OBJECT-TYPE
SYNTAX INTEGER {
prbs-sync(1),
prbs-unsync(2),
prbs-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqe1 PRBS Status"
::= { mqe1LineDiagControlEntry 5 }
mqe1PRBSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqe1 PRBS Elapse Seconds"
::= { mqe1LineDiagControlEntry 6 }
mqe1PRBSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqe1 PRBS Error Seconds"
::= { mqe1LineDiagControlEntry 7 }
mqe1PRBSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqe1 PRBS Error Counts"
::= { mqe1LineDiagControlEntry 8 }
mqe1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of MQE1 inband local, payload, or line loopback"
::= { mqe1LineDiagControlEntry 9 }
--
-- Command Control Table
--
mqe1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { mqe1-card 20 }
mqe1CommandControlEntry OBJECT-TYPE
SYNTAX MQE1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { mqe1Index , mqe1PortIndex }
::= { mqe1CommandControlTable 1 }
MQE1CommandControlEntry ::= SEQUENCE {
mqe1AlarmQueueReset INTEGER,
mqe1UserPerfReset INTEGER,
mqe1AlarmHistoryReset INTEGER,
mqe1PortReset INTEGER,
mqe1PortLoadDefault INTEGER
}
mqe1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { mqe1CommandControlEntry 2 }
mqe1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { mqe1CommandControlEntry 3 }
mqe1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { mqe1CommandControlEntry 4 }
mqe1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset MQE1 Port"
::= { mqe1CommandControlEntry 5 }
mqe1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default MQE1 Port"
::= { mqe1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
mqe1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { mqe1-card 21 }
mqe1SystemInformationEntry OBJECT-TYPE
SYNTAX MQE1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { mqe1Index }
::= { mqe1SystemInformationTable 1 }
MQE1SystemInformationEntry ::= SEQUENCE {
mqe1PROMVersion DisplayString,
mqe1HardwareVersion DisplayString
}
mqe1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" mqe1 PROM Version"
::= { mqe1SystemInformationEntry 2 }
mqe1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" mqe1 Hardware Version"
::= { mqe1SystemInformationEntry 3 }
--
-- Remote Link Identification Table
--
mqe1RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification Table"
::= { mqe1-card 22 }
mqe1RemoteLinkIDEntry OBJECT-TYPE
SYNTAX MQE1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification entry"
INDEX { mqe1Index ,
mqe1PortIndex }
::= { mqe1RemoteLinkIDTable 1 }
MQE1RemoteLinkIDEntry ::= SEQUENCE {
mqe1RemoteLinkIDType INTEGER,
mqe1RemoteLinkIDRack INTEGER,
mqe1RemoteLinkIDSlotNumber INTEGER,
mqe1RemoteLinkIDPort INTEGER,
mqe1RemoteLinkIDSerialNumber INTEGER,
mqe1RemoteLinkIDBackupSlotNUM INTEGER,
mqe1RemoteLinkIDBackupPort INTEGER
}
mqe1RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Type"
::= { mqe1RemoteLinkIDEntry 3 }
mqe1RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { mqe1RemoteLinkIDEntry 4 }
mqe1RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { mqe1RemoteLinkIDEntry 5 }
mqe1RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { mqe1RemoteLinkIDEntry 6 }
mqe1RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { mqe1RemoteLinkIDEntry 7 }
mqe1RemoteLinkIDBackupSlotNUM OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Slot Number"
::= { mqe1RemoteLinkIDEntry 8 }
mqe1RemoteLinkIDBackupPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Port"
::= { mqe1RemoteLinkIDEntry 9 }
--
-- QE1 Customer Information Table
--
mqe1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF MQE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { mqe1-card 99 }
mqe1CustomerInfoEntry OBJECT-TYPE
SYNTAX MQE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { mqe1CISlotIndex , mqe1CIPortIndex }
::= { mqe1CustomerInfoTable 1 }
MQE1CustomerInfoEntry ::= SEQUENCE {
mqe1CISlotIndex SmallSlotIndex,
mqe1CIPortIndex FourPortID,
mqe1CICustomerInfo DisplayString (SIZE(0..64))
}
mqe1CISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { mqe1CustomerInfoEntry 1 }
mqe1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { mqe1CustomerInfoEntry 2 }
mqe1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { mqe1CustomerInfoEntry 3 }
mqe1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of MQE1"
::= { mqe1-card 100 }
--======================================================================--
--======================================================================--
-- mini quad-t1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
mqt1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { mqt1-card 1 }
mqt1LineControlEntry OBJECT-TYPE
SYNTAX Mqt1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { mqt1LCSlotIndex , mqt1LCPortIndex }
::= { mqt1LineControlTable 1 }
Mqt1LineControlEntry ::= SEQUENCE {
mqt1LCSlotIndex SmallSlotIndex,
mqt1LCPortIndex FourPortID,
mqt1LineFrame INTEGER,
mqt1LineCoding INTEGER,
mqt1Interface INTEGER,
mqt1LineBuildOut INTEGER,
mqt1Equalizer INTEGER,
mqt1AIS INTEGER,
mqt1YEL INTEGER,
mqt1Inband INTEGER,
mqt1IdleCode INTEGER,
mqt1CASMode INTEGER,
mqt1SignallingMode INTEGER,
mqt1CGA INTEGER,
mqt1OutOfService INTEGER,
mqt1FDL INTEGER,
mqt1Protect INTEGER,
mqt1Master INTEGER
}
mqt1LCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineControlEntry 1 }
mqt1LCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineControlEntry 2 }
mqt1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esfT1403(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { mqt1LineControlEntry 3 }
mqt1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { mqt1LineControlEntry 4 }
mqt1Interface OBJECT-TYPE
SYNTAX INTEGER {
longHaul(1),
shortHaul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that Mqt1 line use Long/Short haul."
::= { mqt1LineControlEntry 5 }
mqt1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo0dB(1),
lboNeg7p5dB(2),
lboNeg15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mqt1 line build out."
::= { mqt1LineControlEntry 6 }
mqt1Equalizer OBJECT-TYPE
SYNTAX INTEGER {
equ0to110Ft(1),
equ110to220ft(2),
equ220to330ft(3),
equ330to440ft(4),
equ440to550ft(5),
equ550to660ft(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mqt1 line equalizer."
::= { mqt1LineControlEntry 7 }
mqt1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mqt1 line Alarm Indication Signal."
::= { mqt1LineControlEntry 8 }
mqt1YEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { mqt1LineControlEntry 9 }
mqt1Inband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mqt1 line inband ON/OFF"
::= { mqt1LineControlEntry 10 }
mqt1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { mqt1LineControlEntry 11 }
mqt1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { mqt1LineControlEntry 12 }
mqt1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS"
::= { mqt1LineControlEntry 13 }
mqt1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { mqt1LineControlEntry 14 }
mqt1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { mqt1LineControlEntry 15 }
mqt1FDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mqt1 Facility Data Link ON/OFF"
::= { mqt1LineControlEntry 16 }
mqt1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { mqt1LineControlEntry 17 }
mqt1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { mqt1LineControlEntry 18 }
--
-- User Current Performance Table
--
mqt1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { mqt1-card 2 }
mqt1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX Mqt1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { mqt1UCPSlotIndex , mqt1UCPPortIndex }
::= { mqt1UserCurrentPerfTable 1 }
Mqt1UserCurrentPerfEntry ::= SEQUENCE {
mqt1UCPSlotIndex SmallSlotIndex,
mqt1UCPPortIndex FourPortID,
mqt1UserCurrentPerfES INTEGER,
mqt1UserCurrentPerfSES INTEGER,
mqt1UserCurrentPerfBES INTEGER,
mqt1UserCurrentPerfUAS INTEGER,
mqt1UserCurrentPerfCSS INTEGER,
mqt1UserCurrentPerfBPV INTEGER,
mqt1UserCurrentPerfLOFC INTEGER,
mqt1UserCurr15MinTimeElapsed INTEGER,
mqt1UserValid15MinInterval INTEGER
}
mqt1UCPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1UserCurrentPerfEntry 1 }
mqt1UCPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1UserCurrentPerfEntry 2 }
mqt1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1UserCurrentPerfEntry 3 }
mqt1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1UserCurrentPerfEntry 4 }
mqt1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1UserCurrentPerfEntry 5 }
mqt1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1UserCurrentPerfEntry 6 }
mqt1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { mqt1UserCurrentPerfEntry 7 }
mqt1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1UserCurrentPerfEntry 8 }
mqt1UserCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1UserCurrentPerfEntry 9 }
mqt1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { mqt1UserCurrentPerfEntry 10 }
mqt1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { mqt1UserCurrentPerfEntry 11 }
--
-- User Interval Performance Table
--
mqt1UserIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1UserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { mqt1-card 3 }
mqt1UserIntvPerfEntry OBJECT-TYPE
SYNTAX Mqt1UserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { mqt1UIPSlotIndex , mqt1UIPPortIndex , mqt1UserIntvPerfNumber }
::= { mqt1UserIntvPerfTable 1 }
Mqt1UserIntvPerfEntry ::= SEQUENCE {
mqt1UIPSlotIndex SmallSlotIndex,
mqt1UIPPortIndex FourPortID,
mqt1UserIntvPerfNumber INTEGER (1..96),
mqt1UserIntvPerfES INTEGER,
mqt1UserIntvPerfSES INTEGER,
mqt1UserIntvPerfBES INTEGER,
mqt1UserIntvPerfUAS INTEGER,
mqt1UserIntvPerfCSS INTEGER,
mqt1UserIntvPerfBPV INTEGER,
mqt1UserIntvPerfLOFC INTEGER
}
mqt1UIPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1UserIntvPerfEntry 1 }
mqt1UIPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1UserIntvPerfEntry 2 }
mqt1UserIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { mqt1UserIntvPerfEntry 3 }
mqt1UserIntvPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1UserIntvPerfEntry 4 }
mqt1UserIntvPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1UserIntvPerfEntry 5 }
mqt1UserIntvPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1UserIntvPerfEntry 6 }
mqt1UserIntvPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1UserIntvPerfEntry 7 }
mqt1UserIntvPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1UserIntvPerfEntry 8 }
mqt1UserIntvPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1UserIntvPerfEntry 9 }
mqt1UserIntvPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1UserIntvPerfEntry 10 }
--
-- User Total Performance Table
--
mqt1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { mqt1-card 4 }
mqt1UserTotalPerfEntry OBJECT-TYPE
SYNTAX Mqt1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { mqt1UTPSlotIndex , mqt1UTPPortIndex }
::= { mqt1UserTotalPerfTable 1 }
Mqt1UserTotalPerfEntry ::= SEQUENCE {
mqt1UTPSlotIndex SmallSlotIndex,
mqt1UTPPortIndex FourPortID,
mqt1UserTotalPerfES INTEGER,
mqt1UserTotalPerfSES INTEGER,
mqt1UserTotalPerfBES INTEGER,
mqt1UserTotalPerfUAS INTEGER,
mqt1UserTotalPerfCSS INTEGER,
mqt1UserTotalPerfBPV INTEGER,
mqt1UserTotalPerfLOFC INTEGER
}
mqt1UTPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1UserTotalPerfEntry 1 }
mqt1UTPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1UserTotalPerfEntry 2 }
mqt1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1UserTotalPerfEntry 3 }
mqt1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1UserTotalPerfEntry 4 }
mqt1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1UserTotalPerfEntry 5 }
mqt1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1UserTotalPerfEntry 6 }
mqt1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1UserTotalPerfEntry 7 }
mqt1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1UserTotalPerfEntry 8 }
mqt1UserTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1UserTotalPerfEntry 9 }
--
-- User Seven Days Performance Table
--
mqt1User7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1User7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { mqt1-card 22 }
mqt1User7DaysPerfEntry OBJECT-TYPE
SYNTAX Mqt1User7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance entry"
INDEX { mqt1USPSlotIndex , mqt1USPPortIndex , mqt1UserDaysIndex }
::= { mqt1User7DaysPerfTable 1 }
Mqt1User7DaysPerfEntry ::= SEQUENCE {
mqt1USPSlotIndex SmallSlotIndex,
mqt1USPPortIndex FourPortID,
mqt1UserDaysIndex INTEGER (1..7),
mqt1UserDateStrIndex DisplayString (SIZE (0..255) ),
mqt1User7DaysPerfES INTEGER,
mqt1User7DaysPerfSES INTEGER,
mqt1User7DaysPerfBES INTEGER,
mqt1User7DaysPerfUAS INTEGER,
mqt1User7DaysPerfCSS INTEGER
-- mqt1User7DaysPerfLOFC INTEGER
}
mqt1USPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1User7DaysPerfEntry 1 }
mqt1USPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1User7DaysPerfEntry 2 }
mqt1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { mqt1User7DaysPerfEntry 3 }
mqt1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { mqt1User7DaysPerfEntry 4 }
mqt1User7DaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1User7DaysPerfEntry 5 }
mqt1User7DaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1User7DaysPerfEntry 6 }
mqt1User7DaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1User7DaysPerfEntry 7 }
mqt1User7DaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1User7DaysPerfEntry 8 }
mqt1User7DaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1User7DaysPerfEntry 9 }
-- mqt1User7DaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { mqt1User7DaysPerfEntry 10 }
--
-- Line Current Performance Table
--
mqt1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { mqt1-card 8 }
mqt1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX Mqt1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { mqt1LCPSlotIndex , mqt1LCPPortIndex }
::= { mqt1LineCurrentPerfTable 1 }
Mqt1LineCurrentPerfEntry ::= SEQUENCE {
mqt1LCPSlotIndex SmallSlotIndex,
mqt1LCPPortIndex FourPortID,
mqt1LineCurrentPerfES INTEGER,
mqt1LineCurrentPerfSES INTEGER,
mqt1LineCurrentPerfBES INTEGER,
mqt1LineCurrentPerfUAS INTEGER,
mqt1LineCurrentPerfCSS INTEGER,
mqt1LineCurrentPerfBPV INTEGER,
mqt1LineCurrentPerfLOFC INTEGER,
mqt1LineCurr15MinTimeElapsed INTEGER,
mqt1LineValid15MinInterval INTEGER
}
mqt1LCPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineCurrentPerfEntry 1 }
mqt1LCPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineCurrentPerfEntry 2 }
mqt1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { mqt1LineCurrentPerfEntry 3 }
mqt1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1LineCurrentPerfEntry 4 }
mqt1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1LineCurrentPerfEntry 5 }
mqt1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1LineCurrentPerfEntry 6 }
mqt1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1LineCurrentPerfEntry 7 }
mqt1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1LineCurrentPerfEntry 8 }
mqt1LineCurrentPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1LineCurrentPerfEntry 9 }
mqt1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { mqt1LineCurrentPerfEntry 10 }
mqt1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { mqt1LineCurrentPerfEntry 11 }
--
-- Line Interval Performance Table
--
mqt1LineIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { mqt1-card 9 }
mqt1LineIntvPerfEntry OBJECT-TYPE
SYNTAX Mqt1LineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { mqt1LIPSlotIndex , mqt1LIPPortIndex , mqt1LineIntvPerfNumber }
::= { mqt1LineIntvPerfTable 1 }
Mqt1LineIntvPerfEntry ::= SEQUENCE {
mqt1LIPSlotIndex SmallSlotIndex,
mqt1LIPPortIndex FourPortID,
mqt1LineIntvPerfNumber INTEGER (1..96),
mqt1LineIntvPerfES INTEGER,
mqt1LineIntvPerfSES INTEGER,
mqt1LineIntvPerfBES INTEGER,
mqt1LineIntvPerfUAS INTEGER,
mqt1LineIntvPerfCSS INTEGER,
mqt1LineIntvPerfBPV INTEGER,
mqt1LineIntvPerfLOFC INTEGER,
mqt1LineIntvAvailable INTEGER
}
mqt1LIPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineIntvPerfEntry 1 }
mqt1LIPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineIntvPerfEntry 2 }
mqt1LineIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index "
::= { mqt1LineIntvPerfEntry 3 }
mqt1LineIntvPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1LineIntvPerfEntry 4 }
mqt1LineIntvPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1LineIntvPerfEntry 5 }
mqt1LineIntvPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1LineIntvPerfEntry 6 }
mqt1LineIntvPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1LineIntvPerfEntry 7 }
mqt1LineIntvPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1LineIntvPerfEntry 8 }
mqt1LineIntvPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1LineIntvPerfEntry 9 }
mqt1LineIntvPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1LineIntvPerfEntry 10 }
mqt1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { mqt1LineIntvPerfEntry 11 }
--
-- Line Total Performance Table
--
mqt1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { mqt1-card 10 }
mqt1LineTotalPerfEntry OBJECT-TYPE
SYNTAX Mqt1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance entry"
INDEX { mqt1LTPSlotIndex , mqt1LTPPortIndex }
::= { mqt1LineTotalPerfTable 1 }
Mqt1LineTotalPerfEntry ::= SEQUENCE {
mqt1LTPSlotIndex SmallSlotIndex,
mqt1LTPPortIndex FourPortID,
mqt1LineTotalPerfES INTEGER,
mqt1LineTotalPerfSES INTEGER,
mqt1LineTotalPerfBES INTEGER,
mqt1LineTotalPerfUAS INTEGER,
mqt1LineTotalPerfCSS INTEGER,
mqt1LineTotalPerfBPV INTEGER,
mqt1LineTotalPerfLOFC INTEGER
}
mqt1LTPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineTotalPerfEntry 1 }
mqt1LTPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineTotalPerfEntry 2 }
mqt1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1LineTotalPerfEntry 3 }
mqt1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1LineTotalPerfEntry 4 }
mqt1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1LineTotalPerfEntry 5 }
mqt1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1LineTotalPerfEntry 6 }
mqt1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1LineTotalPerfEntry 7 }
mqt1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { mqt1LineTotalPerfEntry 8 }
mqt1LineTotalPerfLOFC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { mqt1LineTotalPerfEntry 9 }
--
-- Line Seven Days Performance Table
--
mqt1Line7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1Line7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { mqt1-card 21 }
mqt1Line7DaysPerfEntry OBJECT-TYPE
SYNTAX Mqt1Line7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { mqt1LSPSlotIndex , mqt1LSPPortIndex , mqt1LineDaysIndex }
::= { mqt1Line7DaysPerfTable 1 }
Mqt1Line7DaysPerfEntry ::= SEQUENCE {
mqt1LSPSlotIndex SmallSlotIndex,
mqt1LSPPortIndex FourPortID,
mqt1LineDaysIndex INTEGER (1..7),
mqt1LineDateStrIndex DisplayString (SIZE (0..255) ),
mqt1Line7DaysPerfES INTEGER,
mqt1Line7DaysPerfSES INTEGER,
mqt1Line7DaysPerfBES INTEGER,
mqt1Line7DaysPerfUAS INTEGER,
mqt1Line7DaysPerfCSS INTEGER
-- mqt1Line7DaysPerfLOFC INTEGER
}
mqt1LSPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1Line7DaysPerfEntry 1 }
mqt1LSPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1Line7DaysPerfEntry 2 }
mqt1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { mqt1Line7DaysPerfEntry 3 }
mqt1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { mqt1Line7DaysPerfEntry 4 }
mqt1Line7DaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { mqt1Line7DaysPerfEntry 5 }
mqt1Line7DaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { mqt1Line7DaysPerfEntry 6 }
mqt1Line7DaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { mqt1Line7DaysPerfEntry 7 }
mqt1Line7DaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { mqt1Line7DaysPerfEntry 8 }
mqt1Line7DaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { mqt1Line7DaysPerfEntry 9 }
-- mqt1Line7DaysPerfLOFC OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " LOFC Counter "
-- ::= { mqt1Line7DaysPerfEntry 9 }
--
-- Alarm Queue Table
--
mqt1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Queue Table"
::= { mqt1-card 11 }
mqt1AlarmQueueEntry OBJECT-TYPE
SYNTAX Mqt1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { mqt1AQSlotIndex , mqt1AlarmQueueIndex }
::= { mqt1AlarmQueueTable 1 }
Mqt1AlarmQueueEntry ::= SEQUENCE {
mqt1AQSlotIndex SmallSlotIndex,
mqt1AlarmQueueIndex INTEGER (1..40),
mqt1AlarmQueueString DisplayString (SIZE(0..255))
}
mqt1AQSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1AlarmQueueEntry 1 }
mqt1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { mqt1AlarmQueueEntry 2 }
mqt1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { mqt1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
mqt1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { mqt1-card 12 }
mqt1AlarmHistoryEntry OBJECT-TYPE
SYNTAX Mqt1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { mqt1AHSlotIndex , mqt1AHPortIndex , mqt1AlarmHistoryIndex }
::= { mqt1AlarmHistoryTable 1 }
Mqt1AlarmHistoryEntry ::= SEQUENCE {
mqt1AHSlotIndex SmallSlotIndex,
mqt1AHPortIndex FourPortID,
mqt1AlarmHistoryIndex INTEGER,
mqt1Threshold INTEGER,
mqt1CurrentState INTEGER,
mqt1CurrentCount INTEGER,
mqt1Alarm AlarmSeverity
}
mqt1AHSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1AlarmHistoryEntry 1 }
mqt1AHPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1AlarmHistoryEntry 2 }
mqt1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
yelLine(1),
aisLine(2),
losLine(3),
lofLine(4),
bpvLine(5),
essLine(6),
uasLine(7),
cssLine(8),
tpca(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { mqt1AlarmHistoryEntry 3 }
mqt1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { mqt1AlarmHistoryEntry 4 }
mqt1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { mqt1AlarmHistoryEntry 5 }
mqt1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { mqt1AlarmHistoryEntry 6 }
mqt1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { mqt1AlarmHistoryEntry 7 }
--
-- Line Availability Table
--
mqt1LineAvailTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { mqt1-card 13 }
mqt1LineAvailEntry OBJECT-TYPE
SYNTAX Mqt1LineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { mqt1LASlotIndex , mqt1LAPortIndex }
::= { mqt1LineAvailTable 1 }
Mqt1LineAvailEntry ::= SEQUENCE {
mqt1LASlotIndex SmallSlotIndex,
mqt1LAPortIndex FourPortID,
mqt1AvailableSeconds DisplayString,
mqt1UnavailableSeconds DisplayString,
mqt1LineAvailability DisplayString
}
mqt1LASlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineAvailEntry 1 }
mqt1LAPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineAvailEntry 2 }
mqt1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { mqt1LineAvailEntry 3 }
mqt1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { mqt1LineAvailEntry 4 }
mqt1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { mqt1LineAvailEntry 5 }
--
-- Alarm Control Table
--
mqt1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqt1-card 14 }
mqt1AlarmControlEntry OBJECT-TYPE
SYNTAX Mqt1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { mqt1ACSlotIndex , mqt1ACPortIndex }
::= { mqt1AlarmControlTable 1 }
Mqt1AlarmControlEntry ::= SEQUENCE {
mqt1ACSlotIndex SmallSlotIndex,
mqt1ACPortIndex FourPortID,
mqt1YELalarm AlarmSeverity,
mqt1AISalarm AlarmSeverity,
mqt1LOSalarm AlarmSeverity,
mqt1LOFalarm AlarmSeverity,
mqt1BPValarm AlarmSeverity,
mqt1ESSalarm AlarmSeverity,
mqt1UASalarm AlarmSeverity,
mqt1CSSalarm AlarmSeverity,
mqt1TCPAalarm AlarmSeverity
}
mqt1ACSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1AlarmControlEntry 1 }
mqt1ACPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1AlarmControlEntry 2 }
mqt1YELalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL State"
::= { mqt1AlarmControlEntry 3 }
mqt1AISalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS State"
::= { mqt1AlarmControlEntry 4 }
mqt1LOSalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS State"
::= { mqt1AlarmControlEntry 5 }
mqt1LOFalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF State"
::= { mqt1AlarmControlEntry 6 }
mqt1BPValarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV State"
::= { mqt1AlarmControlEntry 7 }
mqt1ESSalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS State"
::= { mqt1AlarmControlEntry 8 }
mqt1UASalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS State"
::= { mqt1AlarmControlEntry 9 }
mqt1CSSalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS State"
::= { mqt1AlarmControlEntry 10 }
-- RIKER 2013 NFS-13000027
mqt1TCPAalarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold Crossing Performance Alarm"
::= { mqt1AlarmControlEntry 11 }
--
-- Threshold Control Table
--
mqt1ThresholdCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1ThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqt1-card 15 }
mqt1ThresholdCtrlEntry OBJECT-TYPE
SYNTAX Mqt1ThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { mqt1TCSlotIndex , mqt1TCPortIndex }
::= { mqt1ThresholdCtrlTable 1 }
Mqt1ThresholdCtrlEntry ::= SEQUENCE {
mqt1TCSlotIndex SmallSlotIndex,
mqt1TCPortIndex FourPortID,
mqt1ThresholdBPV INTEGER,
mqt1ThresholdESS INTEGER,
mqt1ThresholdUAS INTEGER,
mqt1ThresholdCSS INTEGER,
mqt1ThresholdTCPA INTEGER
}
mqt1TCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1ThresholdCtrlEntry 1 }
mqt1TCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1ThresholdCtrlEntry 2 }
mqt1ThresholdBPV OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV: 10exp-N"
::= { mqt1ThresholdCtrlEntry 3 }
mqt1ThresholdESS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS "
::= { mqt1ThresholdCtrlEntry 4 }
mqt1ThresholdUAS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS "
::= { mqt1ThresholdCtrlEntry 5 }
mqt1ThresholdCSS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS "
::= { mqt1ThresholdCtrlEntry 6 }
-- RIKER 2013 NFS-13000027
mqt1ThresholdTCPA OBJECT-TYPE
SYNTAX INTEGER (1..1544)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of TCPA "
::= { mqt1ThresholdCtrlEntry 7 }
--
-- Line Diagnostic Control Table
--
mqt1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { mqt1-card 16 }
mqt1LineDiagControlEntry OBJECT-TYPE
SYNTAX Mqt1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { mqt1LDSlotIndex , mqt1LDPortIndex }
::= { mqt1LineDiagControlTable 1 }
Mqt1LineDiagControlEntry ::= SEQUENCE {
mqt1LDSlotIndex SmallSlotIndex,
mqt1LDPortIndex FourPortID,
mqt1LoopbackType INTEGER,
mqt1LoopbackStatus INTEGER,
mqt1QRSSControl INTEGER,
mqt1QRSSStatus INTEGER,
mqt1QRSSElapseSeconds INTEGER,
mqt1QRSSErrorSeconds INTEGER,
mqt1QRSSErrorCounts INTEGER,
mqt1InbandLoopbackPeriod INTEGER
}
mqt1LDSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1LineDiagControlEntry 1 }
mqt1LDPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1LineDiagControlEntry 2 }
mqt1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payloadLoopback(3),
lineLoopback(4),
remoteLlbInbandActive(5),
remotePlbAttActive(6),
remotePlbAnsiActive(7),
remoteLlbAnsiActive(8),
remoteLlbInbandDeactive(9),
remotePlbAttDeactive(10),
remotePlbAnsiDeactive(11),
remoteLlbAnsiDeactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mqt1 Loopback Type"
::= { mqt1LineDiagControlEntry 3 }
mqt1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopbackNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqt1 Loopback Status"
::= { mqt1LineDiagControlEntry 4 }
mqt1QRSSControl OBJECT-TYPE
SYNTAX INTEGER {
qrssDeactive(1),
qrssActiveFull(2),
qrssResetErrorCount(3),
qrssInjectError(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mqt1 QRSS Control"
::= { mqt1LineDiagControlEntry 5 }
mqt1QRSSStatus OBJECT-TYPE
SYNTAX INTEGER {
qrssSync(1),
qrssUnsync(2),
qrssNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqt1 QRSS Status"
::= { mqt1LineDiagControlEntry 6 }
mqt1QRSSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqt1 QRSS Elapse Seconds"
::= { mqt1LineDiagControlEntry 7 }
mqt1QRSSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqt1 QRSS Error Seconds"
::= { mqt1LineDiagControlEntry 8 }
mqt1QRSSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mqt1 QRSS Error Counts"
::= { mqt1LineDiagControlEntry 9 }
mqt1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of Mqt1 inband local, payload, or line loopback"
::= { mqt1LineDiagControlEntry 10 }
--
-- Port Status Table
--
mqt1PortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status table."
::= { mqt1-card 23 }
mqt1PortStatusEntry OBJECT-TYPE
SYNTAX Mqt1PortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"port status entry"
INDEX { mqt1PSSlotIndex , mqt1PSPortIndex }
::= { mqt1PortStatusTable 1 }
Mqt1PortStatusEntry ::= SEQUENCE {
mqt1PSSlotIndex SmallSlotIndex,
mqt1PSPortIndex FourPortID,
mqt1PortLOS INTEGER,
mqt1PortLOF INTEGER,
mqt1PortRcvAIS INTEGER,
mqt1PortRcvYEL INTEGER,
mqt1PortXmtAIS INTEGER,
mqt1PortXmtYEL INTEGER,
mqt1PortBPVcount Integer32,
mqt1PortEScount Integer32
}
mqt1PSSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"slot index"
::= { mqt1PortStatusEntry 1 }
mqt1PSPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port index"
::= { mqt1PortStatusEntry 2 }
mqt1PortLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOS State"
::= { mqt1PortStatusEntry 3 }
mqt1PortLOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LOF State"
::= { mqt1PortStatusEntry 4 }
mqt1PortRcvAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received AIS State"
::= { mqt1PortStatusEntry 5 }
mqt1PortRcvYEL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Received YEL State"
::= { mqt1PortStatusEntry 6 }
mqt1PortXmtAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit AIS State"
::= { mqt1PortStatusEntry 7 }
mqt1PortXmtYEL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Transmit YEL State"
::= { mqt1PortStatusEntry 8 }
mqt1PortBPVcount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BPV count"
::= { mqt1PortStatusEntry 9 }
mqt1PortEScount OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ES count"
::= { mqt1PortStatusEntry 10 }
--
-- Command Control Table
--
mqt1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { mqt1-card 17 }
mqt1CommandControlEntry OBJECT-TYPE
SYNTAX Mqt1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { mqt1CCSlotIndex , mqt1CCPortIndex }
::= { mqt1CommandControlTable 1 }
Mqt1CommandControlEntry ::= SEQUENCE {
mqt1CCSlotIndex SmallSlotIndex,
mqt1CCPortIndex FourPortID,
mqt1AlarmQueueReset INTEGER,
mqt1UserPerfReset INTEGER,
mqt1AlarmHistoryReset INTEGER,
mqt1PortReset INTEGER,
mqt1PortLoadDefault INTEGER
}
mqt1CCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1CommandControlEntry 1 }
mqt1CCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { mqt1CommandControlEntry 2 }
mqt1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { mqt1CommandControlEntry 3 }
mqt1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { mqt1CommandControlEntry 4 }
mqt1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { mqt1CommandControlEntry 5 }
mqt1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Mqt1 Port"
::= { mqt1CommandControlEntry 6 }
mqt1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
loadDefault(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Mqt1 Port"
::= { mqt1CommandControlEntry 7 }
--
-- SYSTEM Information Table
--
mqt1SystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { mqt1-card 18 }
mqt1SystemInfoEntry OBJECT-TYPE
SYNTAX Mqt1SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { mqt1SISlotIndex }
::= { mqt1SystemInfoTable 1 }
Mqt1SystemInfoEntry ::= SEQUENCE {
mqt1SISlotIndex SmallSlotIndex,
mqt1PROMVersion DisplayString,
mqt1HardwareVersion DisplayString
}
mqt1SISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1SystemInfoEntry 1 }
mqt1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" mqt1 PROM Version"
::= { mqt1SystemInfoEntry 2 }
mqt1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" mqt1 Hardware Version"
::= { mqt1SystemInfoEntry 3 }
--
-- Mqt1 Customer Information Table
--
mqt1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Mqt1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { mqt1-card 99 }
mqt1CustomerInfoEntry OBJECT-TYPE
SYNTAX Mqt1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { mqt1CISlotIndex , mqt1CIPortIndex }
::= { mqt1CustomerInfoTable 1 }
Mqt1CustomerInfoEntry ::= SEQUENCE {
mqt1CISlotIndex SmallSlotIndex,
mqt1CIPortIndex FourPortID,
mqt1CICustomerInfo DisplayString (SIZE(0..64))
}
mqt1CISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { mqt1CustomerInfoEntry 1 }
mqt1CIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { mqt1CustomerInfoEntry 2 }
mqt1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { mqt1CustomerInfoEntry 3 }
mqt1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of Mqt1"
::= { mqt1-card 100 }
--======================================================================--
--======================================================================--
-- Dry Contact MIB
--======================================================================--
--======================================================================--
--
-- INPUTS SYSTEM Table
--
dcInputSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF DCInputSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Dry Contact Inputs system control table."
::= { dc-card 1 }
dcInputSystemEntry OBJECT-TYPE
SYNTAX DCInputSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dc inputs system table."
INDEX { dcIndex , dcInputPairIndex }
::= { dcInputSystemTable 1 }
DCInputSystemEntry ::= SEQUENCE {
dcIndex LargeSlotIndex,
dcInputPairIndex INTEGER,
dcAlarmStatus INTEGER,
dcAlarmTrigger AlarmSeverity,
dcAlarmMessage DisplayString (SIZE(0..255))
}
dcIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dcInputSystemEntry 1 }
dcInputPairIndex OBJECT-TYPE
SYNTAX INTEGER {
n1-pair1(1),
n1-pair2(2),
n1-pair3(3),
n1-pair4(4),
n2-pair1(5),
n2-pair2(6),
n2-pair3(7),
n2-pair4(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" N1 Pair 1~4 & N2 Pair 1~4."
::= { dcInputSystemEntry 2 }
dcAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Normal or Alarm."
::= { dcInputSystemEntry 3 }
dcAlarmTrigger OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send Alarm Trap ON or OFF"
::= { dcInputSystemEntry 4 }
dcAlarmMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Message."
::= { dcInputSystemEntry 5 }
--
-- OUTPUTS SYSTEM Table
--
dcOutputSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF DCOutputSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Dry Contact Outputs system control table."
::= { dc-card 2 }
dcOutputSystemEntry OBJECT-TYPE
SYNTAX DCOutputSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dc outputs system table."
INDEX { dcIndex , dcOutputPairIndex }
::= { dcOutputSystemTable 1 }
DCOutputSystemEntry ::= SEQUENCE {
dcOutputPairIndex INTEGER,
dcRelayStatus INTEGER,
dcRelaySetup INTEGER
}
dcOutputPairIndex OBJECT-TYPE
SYNTAX INTEGER {
u1(1),
u2(2),
u3(3),
u4(4),
u5(5),
u6(6),
u7(7),
u8(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" U1~U8."
::= { dcOutputSystemEntry 2 }
dcRelayStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
operated(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Normal or Operated."
::= { dcOutputSystemEntry 3 }
dcRelaySetup OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
operated(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Relay Open or Short."
::= { dcOutputSystemEntry 4 }
--
-- Command Control Table
--
dcCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DCCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { dc-card 3 }
dcCommandControlEntry OBJECT-TYPE
SYNTAX DCCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { dcIndex }
::= { dcCommandControlTable 1 }
DCCommandControlEntry ::= SEQUENCE {
dcUnitLoadDefault INTEGER,
dcChannel INTEGER,
dcCtrlRelayOutput INTEGER
}
dcUnitLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Dry Contact"
::= { dcCommandControlEntry 2 }
dcChannel OBJECT-TYPE
SYNTAX INTEGER {
controller(1),
ds0x2(2),
ds0x16(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Dry Contact Channel"
::= { dcCommandControlEntry 3 }
dcCtrlRelayOutput OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CTRL relay output"
::= { dcCommandControlEntry 4 }
--
-- SYSTEM Information Table
--
dcSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DCSystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { dc-card 4 }
dcSystemInfoEntry OBJECT-TYPE
SYNTAX DCSystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX {
dcIndex
}
::= { dcSystemInformationTable 1 }
DCSystemInformation ::= SEQUENCE {
dcFPGAVersion DisplayString
}
dcFPGAVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Dry Contact FPGA Version"
::= { dcSystemInfoEntry 2 }
--
-- Input Relay Control Table
--
dcInputRelayCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcInputRelayCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { dc-card 5 }
dcInputRelayCtrlEntry OBJECT-TYPE
SYNTAX DcInputRelayCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Input Relay Control Table."
INDEX { dcnIndex , dcnInputPairIndex }
::= { dcInputRelayCtrlTable 1 }
DcInputRelayCtrlEntry ::= SEQUENCE {
dcnIndex LargeSlotIndex,
dcnInputPairIndex INTEGER,
dcTrigger INTEGER
}
dcnIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dcInputRelayCtrlEntry 1 }
dcnInputPairIndex OBJECT-TYPE
SYNTAX INTEGER {
n1-pair1(1),
n1-pair2(2),
n1-pair3(3),
n1-pair4(4),
n2-pair1(5),
n2-pair2(6),
n2-pair3(7),
n2-pair4(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" N1 Pair 1~4 & N2 Pair 1~4."
::= { dcInputRelayCtrlEntry 2 }
dcTrigger OBJECT-TYPE
SYNTAX INTEGER {
normal-close(1),
normal-open(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Dry Contact normal(0/1)"
::= { dcInputRelayCtrlEntry 3 }
dcTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 8DC"
::= { dc-card 100 }
--======================================================================--
--======================================================================--
-- FOM MIB
--======================================================================--
--======================================================================--
--
-- SYSTEM Control Table
--
fomSystemControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FOMSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 control table."
::= { fom-card 1 }
fomSystemControlEntry OBJECT-TYPE
SYNTAX FOMSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the FOM control table."
INDEX { fomIndex , fomPortIndex }
::= { fomSystemControlTable 1 }
FOMSystemControlEntry ::= SEQUENCE {
fomIndex GenSlotID,
fomPortIndex FourPortID,
fomFrame INTEGER,
fomCRC INTEGER,
fomRAI INTEGER,
fomCAS INTEGER,
fomAIS INTEGER,
fomIdleCode INTEGER,
fomSabit INTEGER,
fomSSM INTEGER,
fomOOS INTEGER
}
fomIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { fomSystemControlEntry 1 }
fomPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { fomSystemControlEntry 2 }
fomFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FOM E1 frame format"
::= { fomSystemControlEntry 3 }
fomCRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FOM E1 Cycle Redundancy Check OFF/ON"
::= { fomSystemControlEntry 4 }
fomRAI OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { fomSystemControlEntry 5 }
fomCAS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { fomSystemControlEntry 6 }
fomAIS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
unframe(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS OFF/UNFRAME"
::= { fomSystemControlEntry 7 }
fomIdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Idle Code Value"
::= { fomSystemControlEntry 8 }
fomSabit OBJECT-TYPE
SYNTAX INTEGER {
not-support(0),
sa4(4),
sa5(5),
sa6(6),
sa7(7),
sa8(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Sa bit"
::= { fomSystemControlEntry 9 }
fomSSM OBJECT-TYPE
SYNTAX INTEGER {
not-support(0),
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SSM OFF/ON"
::= { fomSystemControlEntry 10 }
fomOOS OBJECT-TYPE
SYNTAX INTEGER {
b0001(1),
b0010(2),
b0011(3),
b0100(4),
b0101(5),
b0110(6),
b0111(7),
b1000(8),
b1001(9),
b1010(10),
b1011(11),
b1100(12),
b1101(13),
b1110(14),
b1111(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OOS"
::= { fomSystemControlEntry 11 }
--
-- FOM Status Table
--
fomStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The FOM status table."
::= { fom-card 2 }
fomStatusEntry OBJECT-TYPE
SYNTAX FomStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the FOM status table."
INDEX {
fomIndex ,
fomPortIndex ,
fomStatusNumIndex
}
::= { fomStatusTable 1 }
FomStatusEntry ::= SEQUENCE {
fomStatusNumIndex INTEGER,
fomType INTEGER,
fomOpticalLOS INTEGER,
fomOpticalLOF INTEGER,
fomOpticalFE INTEGER,
fomOpticalFCS INTEGER,
fomOpticalEOC INTEGER,
fomE1LOF INTEGER,
fomE1CRC INTEGER,
fomE1RxAIS INTEGER,
fomE1RxRAI INTEGER,
fomE1TxAIS INTEGER,
fomE1TxRAI INTEGER,
fomE1LOS INTEGER,
fomE1BPVCRC INTEGER
}
fomStatusNumIndex OBJECT-TYPE
SYNTAX INTEGER {
local(1),
remote(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" local or Remote Status "
::= { fomStatusEntry 2 }
fomType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
fom-8M-Stand-Alone-With-CPU(2),
fom-8M-Stand-Alone-Without-CPU(4),
fom-8M-Card(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Type "
::= { fomStatusEntry 3 }
fomOpticalLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical LOS "
::= { fomStatusEntry 4 }
fomOpticalLOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical LOF "
::= { fomStatusEntry 5 }
fomOpticalFE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical Framing Error Counter "
::= { fomStatusEntry 6 }
fomOpticalFCS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical Frame Checksum Error Counter "
::= { fomStatusEntry 7 }
fomOpticalEOC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical EOC-M Frame Checksum Error Counter "
::= { fomStatusEntry 8 }
fomE1LOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
xx(3),
lossOfCas(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom E1 LOF "
::= { fomStatusEntry 9 }
fomE1CRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom E1 CRC Error Counter "
::= { fomStatusEntry 10 }
fomE1RxAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FOM E1 line Rx Alarm Indication Signal."
::= { fomStatusEntry 11 }
fomE1RxRAI OBJECT-TYPE
SYNTAX INTEGER {
no(1),
rai(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FOM E1 line Rx Remote Alarm Indication."
::= { fomStatusEntry 12 }
fomE1TxAIS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
ais(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FOM E1 line Tx Alarm Indication Signal."
::= { fomStatusEntry 13 }
fomE1TxRAI OBJECT-TYPE
SYNTAX INTEGER {
no(1),
rai(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FOM E1 line Tx Remote Alarm Indication."
::= { fomStatusEntry 14 }
fomE1LOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
xx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote O9310 E1 LOS "
::= { fomStatusEntry 15 }
fomE1BPVCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote E1 BPV or CRC Error Counter "
::= { fomStatusEntry 16 }
--
-- Diagnostic Control Table
--
fomDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { fom-card 3 }
fomDiagEntry OBJECT-TYPE
SYNTAX FomDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { fomIndex ,
fomPortIndex }
::= { fomDiagTable 1 }
FomDiagEntry ::= SEQUENCE {
fomLocalOpticalLoopback INTEGER,
fomLocalE1Loopback INTEGER,
fomRemoteOpticalLoopback INTEGER,
fomRemoteE1Loopback INTEGER,
fomBertControl INTEGER,
fomBertStatus INTEGER,
fomElapseSeconds INTEGER,
fomErrorSeconds INTEGER,
fomErrorBits INTEGER,
fomAccessRemoteLB INTEGER,
fomRemoteCallLocalOpticalLB INTEGER,
fomRemoteCallLocalE1LB INTEGER
}
fomLocalOpticalLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
-- local-loopback(2),
line-loopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom Local Optical Loopback Type"
::= { fomDiagEntry 2 }
fomLocalE1Loopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payLoad-loopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom Local E1 Loopback Type"
::= { fomDiagEntry 3 }
fomRemoteOpticalLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
-- local-loopback(2),
payLoad-loopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom Remote Optical Loopback Type"
::= { fomDiagEntry 4 }
fomRemoteE1Loopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payLoad-loopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom Remote E1 Loopback Type"
::= { fomDiagEntry 5 }
fomBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
bert-on(2),
reset(3),
inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Control"
::= { fomDiagEntry 6 }
fomBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { fomDiagEntry 7 }
fomElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapse seconds"
::= { fomDiagEntry 8 }
fomErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error seconds"
::= { fomDiagEntry 9 }
fomErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error bits"
::= { fomDiagEntry 10 }
fomAccessRemoteLB OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FOM Access Remote Loopback Control"
::= { fomDiagEntry 11 }
fomRemoteCallLocalOpticalLB OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payLoad-loopback(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Called Local Optical Loopback Type"
::= { fomDiagEntry 12 }
fomRemoteCallLocalE1LB OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payLoad-loopback(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Called Local E1 Loopback Type"
::= { fomDiagEntry 13 }
--
-- Alarm Status Table
--
fomAlmStatusTable OBJECT IDENTIFIER ::= { fom-card 4 }
--
-- FOM Optical Alarm Status Table
--
fomOpticalAlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Fom Optical Alarm Status Table "
::= { fomAlmStatusTable 1 }
fomOpticalAlmStatusEntry OBJECT-TYPE
SYNTAX FomOpticalAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { fomIndex ,
fomOpticalAlmNumber }
::= { fomOpticalAlmStatusTable 1 }
FomOpticalAlmStatusEntry ::= SEQUENCE {
fomOpticalAlmNumber INTEGER (1..40),
fomOpticalAlmString DisplayString,
fomOpticalAlmState INTEGER,
fomOpticalAlmCount INTEGER,
fomOpticalAlmThreshold INTEGER,
fomOpticalAlmEnable AlarmSeverity
}
fomOpticalAlmNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom optical Alarm Status Index "
::= { fomOpticalAlmStatusEntry 2 }
fomOpticalAlmString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fom optical Alarm Type String"
::= { fomOpticalAlmStatusEntry 3 }
fomOpticalAlmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom optical Alarm Current State"
::= { fomOpticalAlmStatusEntry 4 }
fomOpticalAlmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom optical Alarm Count which happened "
::= { fomOpticalAlmStatusEntry 5 }
fomOpticalAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Fom optical Alarm Threshold "
::= { fomOpticalAlmStatusEntry 6 }
fomOpticalAlmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom optical Alarm is enabled or not"
::= { fomOpticalAlmStatusEntry 7 }
--
-- FOM E1 Alarm Status Table
--
fomE1AlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomE1AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Fom E1 Alarm Status Table "
::= { fomAlmStatusTable 2 }
fomE1AlmStatusEntry OBJECT-TYPE
SYNTAX FomE1AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { fomIndex ,
fomPortIndex ,
fomE1AlmNumber }
::= { fomE1AlmStatusTable 1 }
FomE1AlmStatusEntry ::= SEQUENCE {
fomE1AlmNumber INTEGER (1..40),
fomE1AlmString DisplayString,
fomE1AlmState INTEGER,
fomE1AlmCount INTEGER,
fomE1AlmThreshold INTEGER,
fomE1AlmEnable AlarmSeverity
}
fomE1AlmNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom E1 Alarm Status Index "
::= { fomE1AlmStatusEntry 3 }
fomE1AlmString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fom E1 Alarm Type String"
::= { fomE1AlmStatusEntry 4 }
fomE1AlmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom E1 Alarm Current State"
::= { fomE1AlmStatusEntry 5 }
fomE1AlmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom E1 Alarm Count which happened "
::= { fomE1AlmStatusEntry 6 }
fomE1AlmThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Fom E1 Alarm Threshold "
::= { fomE1AlmStatusEntry 7 }
fomE1AlmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Fom E1 Alarm is enabled or not"
::= { fomE1AlmStatusEntry 8 }
--
-- Command Control Table
--
fomCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { fom-card 5 }
fomCommandControlEntry OBJECT-TYPE
SYNTAX FomCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { fomIndex ,
fomPortIndex }
::= { fomCommandControlTable 1 }
FomCommandControlEntry ::= SEQUENCE {
fomClearAlarmHistory INTEGER,
fomClearOpticalError INTEGER,
fomClearE1CRCError INTEGER,
fomClearAllErrorCounters INTEGER,
fomUnitLoadDefault INTEGER,
fomClearPerformanceData INTEGER
}
fomClearAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm History"
::= { fomCommandControlEntry 2 }
fomClearOpticalError OBJECT-TYPE
SYNTAX INTEGER {
no(0),
all-counters(1),
fe-counter(2),
fcs-counter(3),
eoc-counter(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Optical Error Counter"
::= { fomCommandControlEntry 3 }
fomClearE1CRCError OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear E1 CRC Error Counter"
::= { fomCommandControlEntry 4 }
fomClearAllErrorCounters OBJECT-TYPE
SYNTAX INTEGER {
no(0),
local(1),
remote(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear All Local or Remote Error Counters"
::= { fomCommandControlEntry 5 }
fomUnitLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Fom"
::= { fomCommandControlEntry 6 }
fomClearPerformanceData OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear performance data"
::= { fomCommandControlEntry 7 }
--
-- SYSTEM Information Table
--
fomSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomSystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= {fom-card 6 }
fomSystemInfoEntry OBJECT-TYPE
SYNTAX FomSystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX {
fomIndex
}
::= { fomSystemInformationTable 1 }
FomSystemInformation ::= SEQUENCE {
fomFPGAVersion DisplayString,
fomPCBVersion DisplayString,
fomLinkID INTEGER,
fomRemoteLinkID INTEGER
}
fomFPGAVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom FPGA Version"
::= { fomSystemInfoEntry 2 }
fomPCBVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom PCB Version"
::= { fomSystemInfoEntry 3 }
fomLinkID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Local Link ID or Serial Number "
::= { fomSystemInfoEntry 4 }
fomRemoteLinkID OBJECT-TYPE
SYNTAX INTEGER{
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Remote Link ID or Serial Number "
::= { fomSystemInfoEntry 5 }
--
-- FOM Optical Type Table
--
fomOpticalTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The FOM Optical Type table."
::= { fom-card 7 }
fomOpticalTypeEntry OBJECT-TYPE
SYNTAX FomOpticalTypeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the FOM Optical Type table."
INDEX {
fomIndex }
::= { fomOpticalTypeTable 1 }
FomOpticalTypeEntry ::= SEQUENCE {
fomOpticalOutline INTEGER,
fomOpticalType INTEGER,
fomOpticalXMTDistance INTEGER
}
fomOpticalOutline OBJECT-TYPE
SYNTAX INTEGER {
sc(1),
fc(2),
unknown(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Optical Outline "
::= { fomOpticalTypeEntry 2 }
fomOpticalType OBJECT-TYPE
SYNTAX INTEGER {
dual-1310(1),
dual-1550(2),
single-m(3),
single-s(4),
unknown(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical Type "
::= { fomOpticalTypeEntry 3 }
fomOpticalXMTDistance OBJECT-TYPE
SYNTAX INTEGER {
small(1),
middle(2),
large(3),
other(4),
unknown(15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Fom Optical XMT Distance "
::= { fomOpticalTypeEntry 4 }
--
-- FOM APSD Setup
--
fomApsdSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomApsdSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The FOM APSD Setup table."
::= { fom-card 8 }
fomApsdSetupEntry OBJECT-TYPE
SYNTAX FomApsdSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the FOM APSD Setup table."
INDEX { fomIndex }
::= { fomApsdSetupTable 1 }
FomApsdSetupEntry ::= SEQUENCE {
fomApsdEnable INTEGER,
fomPulseRepeatTime INTEGER,
fomManualRestart INTEGER,
fomLaserStatus INTEGER
}
fomApsdEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Optical APSD Enable "
::= { fomApsdSetupEntry 2 }
fomPulseRepeatTime OBJECT-TYPE
SYNTAX INTEGER (100..300)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Laser Pulse repetition time for automatic restart(sec) "
::= { fomApsdSetupEntry 3 }
fomManualRestart OBJECT-TYPE
SYNTAX INTEGER {
off(1),
start(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Laser Manual Restart "
::= { fomApsdSetupEntry 4 }
fomLaserStatus OBJECT-TYPE
SYNTAX INTEGER {
laser-on(1),
laser-off(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Laser Status "
::= { fomApsdSetupEntry 5 }
--
-- FOM Current Performance Table
--
fomCurrentPerfTable OBJECT IDENTIFIER ::= { fom-card 9 }
--
-- FOM Optical Current Performance Table
--
fomOpticalCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical Current Performance Table"
::= { fomCurrentPerfTable 1 }
fomOpticalCurrentPerfEntry OBJECT-TYPE
SYNTAX FomOpticalCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical current performance entry"
INDEX { fomIndex }
::= { fomOpticalCurrentPerfTable 1 }
FomOpticalCurrentPerfEntry ::= SEQUENCE {
fomOpticalCurrentPerfES INTEGER,
fomOpticalCurrentPerfSES INTEGER,
fomOpticalCurrentPerfUAS INTEGER,
fomOpticalCurr15MinTimeElapsed INTEGER,
fomOpticalValid15MinInterval INTEGER
}
fomOpticalCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { fomOpticalCurrentPerfEntry 2 }
fomOpticalCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomOpticalCurrentPerfEntry 3 }
fomOpticalCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomOpticalCurrentPerfEntry 4 }
fomOpticalCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { fomOpticalCurrentPerfEntry 5 }
fomOpticalValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { fomOpticalCurrentPerfEntry 6 }
--
-- FOM E1 Current Performance Table
--
fomE1CurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomE1CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 Current Performance Table"
::= { fomCurrentPerfTable 2 }
fomE1CurrentPerfEntry OBJECT-TYPE
SYNTAX FomE1CurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 current performance entry"
INDEX { fomIndex ,
fomPortIndex }
::= { fomE1CurrentPerfTable 1 }
FomE1CurrentPerfEntry ::= SEQUENCE {
fomE1CurrentPerfES INTEGER,
fomE1CurrentPerfSES INTEGER,
fomE1CurrentPerfUAS INTEGER,
fomE1CurrentPerfCRC INTEGER,
fomE1Curr15MinTimeElapsed INTEGER,
fomE1Valid15MinInterval INTEGER
}
fomE1CurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { fomE1CurrentPerfEntry 3 }
fomE1CurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomE1CurrentPerfEntry 4 }
fomE1CurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomE1CurrentPerfEntry 5 }
fomE1CurrentPerfCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CRC Error Counter "
::= { fomE1CurrentPerfEntry 6 }
fomE1Curr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { fomE1CurrentPerfEntry 7 }
fomE1Valid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { fomE1CurrentPerfEntry 8 }
--
-- FOM Interval Performance Table
--
fomIntervalPerfTable OBJECT IDENTIFIER ::= { fom-card 10 }
--
-- FOM Optical Interval Performance Table
--
fomOpticalIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalIntervalPerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical Interval Performance Table"
::= { fomIntervalPerfTable 1 }
fomOpticalIntervalPerEntry OBJECT-TYPE
SYNTAX FomOpticalIntervalPerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical interval performance entry"
INDEX { fomIndex ,
fomIntervalPerfNumber }
::= { fomOpticalIntervalPerfTable 1 }
FomOpticalIntervalPerEntry ::= SEQUENCE {
fomIntervalPerfNumber INTEGER (1..96),
fomOpticalIntervalPerfES INTEGER,
fomOpticalIntervalPerfSES INTEGER,
fomOpticalIntervalPerfUAS INTEGER
}
fomIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { fomOpticalIntervalPerEntry 2 }
fomOpticalIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomOpticalIntervalPerEntry 3 }
fomOpticalIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomOpticalIntervalPerEntry 4 }
fomOpticalIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomOpticalIntervalPerEntry 5 }
--
-- FOM E1 Interval Performance Table
--
fomE1IntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomE1IntervalPerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 Interval Performance Table"
::= { fomIntervalPerfTable 2 }
fomE1IntervalPerEntry OBJECT-TYPE
SYNTAX FomE1IntervalPerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 interval performance entry"
INDEX { fomIndex ,
fomPortIndex ,
fomIntervalPerfNumber }
::= { fomE1IntervalPerfTable 1 }
FomE1IntervalPerEntry ::= SEQUENCE {
fomE1IntervalPerfES INTEGER,
fomE1IntervalPerfSES INTEGER,
fomE1IntervalPerfUAS INTEGER,
fomE1IntervalPerfCRC INTEGER
}
fomE1IntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomE1IntervalPerEntry 4 }
fomE1IntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomE1IntervalPerEntry 5 }
fomE1IntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomE1IntervalPerEntry 6 }
fomE1IntervalPerfCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CRC Error Counter "
::= { fomE1IntervalPerEntry 7 }
--
-- FOM Total Performance Table
--
fomTotalPerfTable OBJECT IDENTIFIER ::= { fom-card 11 }
--
-- FOM Optical Total Performance Table
--
fomOpticalTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical Total Performance Table"
::= { fomTotalPerfTable 1 }
fomOpticalTotalPerfEntry OBJECT-TYPE
SYNTAX FomOpticalTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical Total performance table"
INDEX { fomIndex }
::= { fomOpticalTotalPerfTable 1 }
FomOpticalTotalPerfEntry ::= SEQUENCE {
fomOpticalTotalPerfES INTEGER,
fomOpticalTotalPerfSES INTEGER,
fomOpticalTotalPerfUAS INTEGER
}
fomOpticalTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomOpticalTotalPerfEntry 2 }
fomOpticalTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomOpticalTotalPerfEntry 3 }
fomOpticalTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomOpticalTotalPerfEntry 4 }
--
-- FOM E1 Total Performance Table
--
fomE1TotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomE1TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 Total Performance Table"
::= { fomTotalPerfTable 2 }
fomE1TotalPerfEntry OBJECT-TYPE
SYNTAX FomE1TotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 Total performance table"
INDEX { fomIndex ,
fomPortIndex }
::= { fomE1TotalPerfTable 1 }
FomE1TotalPerfEntry ::= SEQUENCE {
fomE1TotalPerfES INTEGER,
fomE1TotalPerfSES INTEGER,
fomE1TotalPerfUAS INTEGER,
fomE1TotalPerfCRC INTEGER
}
fomE1TotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomE1TotalPerfEntry 3 }
fomE1TotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomE1TotalPerfEntry 4 }
fomE1TotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomE1TotalPerfEntry 5 }
fomE1TotalPerfCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CRC Error Counter "
::= { fomE1TotalPerfEntry 6 }
--
-- FOM Seven Days Performance Table
--
fomSevenDaysPerfTable OBJECT IDENTIFIER ::= { fom-card 12 }
--
-- FOM Optical Seven Days Performance Table
--
fomOpticalSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomOpticalSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical 7 Days Performance Table"
::= { fomSevenDaysPerfTable 1 }
fomOpticalSevenDaysPerfEntry OBJECT-TYPE
SYNTAX FomOpticalSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical 7 days performance entry"
INDEX { fomIndex ,
fomDaysIndex }
::= { fomOpticalSevenDaysPerfTable 1 }
FomOpticalSevenDaysPerfEntry ::= SEQUENCE {
fomDaysIndex INTEGER (1..7),
fomOpticalDateStrIndex DisplayString (SIZE (0..255) ),
fomOpticalSevenDaysPerfES INTEGER,
fomOpticalSevenDaysPerfSES INTEGER,
fomOpticalSevenDaysPerfUAS INTEGER
}
fomDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { fomOpticalSevenDaysPerfEntry 2 }
fomOpticalDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { fomOpticalSevenDaysPerfEntry 3 }
fomOpticalSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomOpticalSevenDaysPerfEntry 4 }
fomOpticalSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomOpticalSevenDaysPerfEntry 5 }
fomOpticalSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomOpticalSevenDaysPerfEntry 6 }
--
-- FOM E1 Seven Days Performance Table
--
fomE1SevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FomE1SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 7 Days Performance Table"
::= { fomSevenDaysPerfTable 2 }
fomE1SevenDaysPerfEntry OBJECT-TYPE
SYNTAX FomE1SevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM E1 7 days performance entry"
INDEX { fomIndex ,
fomPortIndex ,
fomDaysIndex }
::= { fomE1SevenDaysPerfTable 1 }
FomE1SevenDaysPerfEntry ::= SEQUENCE {
fomE1DateStrIndex DisplayString (SIZE (0..255) ),
fomE1SevenDaysPerfES INTEGER,
fomE1SevenDaysPerfSES INTEGER,
fomE1SevenDaysPerfUAS INTEGER,
fomE1SevenDaysPerfCRC INTEGER
}
fomE1DateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { fomE1SevenDaysPerfEntry 4 }
fomE1SevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { fomE1SevenDaysPerfEntry 5 }
fomE1SevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { fomE1SevenDaysPerfEntry 6 }
fomE1SevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { fomE1SevenDaysPerfEntry 7 }
fomE1SevenDaysPerfCRC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CRC Error Counter "
::= { fomE1SevenDaysPerfEntry 8 }
--
-- FOM Remote Led Status Table
--
-- fomRemoteLedStatusTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF FomRemoteLedStatusEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "FOM remote led status Table"
-- ::= { fom-card 13 }
--
-- fomRemoteLedStatusEntry OBJECT-TYPE
-- SYNTAX FomRemoteLedStatusEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "FOM remote led status entry"
-- INDEX { fomIndex,
-- fomRemLedIndex }
-- ::= { fomRemoteLedStatusTable 1 }
--
-- FomRemoteLedStatusEntry ::=
-- SEQUENCE {
-- fomRemLedIndex
-- INTEGER,
-- fomRemLedName
-- DisplayString,
-- fomRemLedColor
-- INTEGER
-- }
--
-- fomRemLedIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Remote Led Index"
-- ::= { fomRemoteLedStatusEntry 2 }
--
-- fomRemLedName OBJECT-TYPE
-- SYNTAX DisplayString
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Remote Led Name"
-- ::= { fomRemoteLedStatusEntry 3 }
--
-- fomRemLedColor OBJECT-TYPE
-- SYNTAX INTEGER {
-- none(0),
-- off(1),
-- red(2),
-- green(3),
-- yellow(4),
-- redFlash(5),
-- greenFlash(6),
-- yellowFlash(7),
-- greenFlashRed(8),
-- not_available(255)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Remote Led Color"
-- ::= { fomRemoteLedStatusEntry 4 }
fomTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of FOM"
::= { fom-card 100 }
--======================================================================--
--======================================================================--
-- Router-A MIB
--======================================================================--
--======================================================================--
--
-- Alarm Status Table
--
r2AlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Status Table "
::= { router-a-card 1 }
r2AlmStatusEntry OBJECT-TYPE
SYNTAX R2AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { r2Index ,
r2AlmStatusNumber }
::= { r2AlmStatusTable 1 }
R2AlmStatusEntry ::= SEQUENCE {
r2Index SmallSlotIndex,
r2AlmStatusNumber INTEGER (1..40),
r2AlmStatusString DisplayString,
r2AlmStatusState INTEGER,
r2AlmStatusCount INTEGER,
r2AlmStatusEnable AlarmSeverity
}
r2Index OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2AlmStatusEntry 1 }
r2AlmStatusNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Status Index "
::= { r2AlmStatusEntry 2 }
r2AlmStatusString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { r2AlmStatusEntry 3 }
r2AlmStatusState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { r2AlmStatusEntry 4 }
r2AlmStatusCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { r2AlmStatusEntry 5 }
r2AlmStatusEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { r2AlmStatusEntry 6 }
--
-- Command Control Table
--
r2CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { router-a-card 2 }
r2CommandControlEntry OBJECT-TYPE
SYNTAX R2CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { r2Index }
::= { r2CommandControlTable 1 }
R2CommandControlEntry ::= SEQUENCE {
r2ClearAlarmHistory INTEGER,
r2LoadDefaultAlarmCfg INTEGER,
r2Reset INTEGER,
r2ReturnToDefault INTEGER,
r2SaveConfig INTEGER
}
r2ClearAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm History"
::= { r2CommandControlEntry 2 }
r2LoadDefaultAlarmCfg OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Alarm Config"
::= { r2CommandControlEntry 3 }
r2Reset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Card"
::= { r2CommandControlEntry 4 }
r2ReturnToDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
return-to-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Return to default"
::= { r2CommandControlEntry 5 }
r2SaveConfig OBJECT-TYPE
SYNTAX INTEGER {
no(0),
save-config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Save config"
::= { r2CommandControlEntry 6 }
--
-- R2 Bridge
--
r2Bridge OBJECT IDENTIFIER ::= { router-a-card 3 }
--
-- R2 Create and Destroy Bridge
--
r2CreateDestroyBridge OBJECT-TYPE
SYNTAX SEQUENCE OF R2CreateDestroyBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R2 Create and Destroy Bridge Table."
::= { r2Bridge 1 }
r2CreateDestroyBridgeEntry OBJECT-TYPE
SYNTAX R2CreateDestroyBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R2 Create and Destroy Bridge Entry"
INDEX { r2Index }
::= { r2CreateDestroyBridge 1 }
R2CreateDestroyBridgeEntry ::= SEQUENCE {
r2BridgeName DisplayString,
r2BridgeMacAddr DisplayString,
r2BridgeCMD INTEGER
}
r2BridgeName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Name"
::= { r2CreateDestroyBridgeEntry 2 }
r2BridgeMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Management Mac (xx:xx:xx:xx:xx:xx)"
::= { r2CreateDestroyBridgeEntry 3 }
r2BridgeCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
create(1),
destroy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Index"
::= { r2CreateDestroyBridgeEntry 4 }
--
-- R2 Bridge Config Table
--
r2BridgeCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2BridgeCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R2 Bridge Config Table."
::= { r2Bridge 2 }
r2BridgeCFGEntry OBJECT-TYPE
SYNTAX R2BridgeCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R2 Bridge Config Entry"
INDEX { r2Index ,
r2BrgGroupID }
::= { r2BridgeCFG 1 }
R2BridgeCFGEntry ::= SEQUENCE {
r2BrgGroupID INTEGER,
r2BrgName DisplayString,
r2BrgManagementAddr DisplayString,
r2BrgManagementMac DisplayString,
r2BrgMacAgingTime INTEGER,
r2BrgCRC INTEGER,
r2BrgManageState INTEGER,
r2BrgInboundPolicy DisplayString,
r2BrgOutboundPolicy DisplayString,
r2BrgSTPState INTEGER,
r2BrgSTPProtocolVersion INTEGER,
r2BrgSTPHelloTime INTEGER,
r2BrgSTPMacAgingTime INTEGER,
r2BrgSTPForwardDelay INTEGER,
r2BrgSTPPriority INTEGER,
r2BrgL2PDUtunneling INTEGER,
r2BrgRoutingProtocol INTEGER
}
r2BrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group ID"
::= { r2BridgeCFGEntry 2 }
r2BrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group Name"
::= { r2BridgeCFGEntry 3 }
r2BrgManagementAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Management IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2BridgeCFGEntry 4 }
r2BrgManagementMac OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Management Mac (xx:xx:xx:xx:xx:xx)"
::= { r2BridgeCFGEntry 5 }
r2BrgMacAgingTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge MAC Aging Time(10-1000000 Sec)"
::= { r2BridgeCFGEntry 6 }
r2BrgCRC OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Disable/Enable CRC"
::= { r2BridgeCFGEntry 7 }
r2BrgManageState OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicated whether the mgmt attached with epilogue"
::= { r2BridgeCFGEntry 8 }
r2BrgInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Inbound policy"
::= { r2BridgeCFGEntry 9 }
r2BrgOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Inbound policy"
::= { r2BridgeCFGEntry 10 }
r2BrgSTPState OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree disable/enable"
::= { r2BridgeCFGEntry 11 }
r2BrgSTPProtocolVersion OBJECT-TYPE
SYNTAX INTEGER {
stp(1),
rstp(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Protocol Version"
::= { r2BridgeCFGEntry 12 }
r2BrgSTPHelloTime OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Hello Time(1-10 Sec)"
::= { r2BridgeCFGEntry 13 }
r2BrgSTPMacAgingTime OBJECT-TYPE
SYNTAX INTEGER (6..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Aging Time(6-40 Sec)"
::= { r2BridgeCFGEntry 14 }
r2BrgSTPForwardDelay OBJECT-TYPE
SYNTAX INTEGER (4..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Forward Delay Time(4-30 Sec)"
::= { r2BridgeCFGEntry 15 }
r2BrgSTPPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Priority (0-65535)"
::= { r2BridgeCFGEntry 16 }
r2BrgL2PDUtunneling OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Disable/Enable BPDU"
::= { r2BridgeCFGEntry 17 }
r2BrgRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
ripV1(1),
ripV2(2),
disable(4),
notSupport(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Bridge routing protocol"
::= { r2BridgeCFGEntry 18 }
--
-- R2 Bridge STP Info
--
r2BrgSTPInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R2BrgSTPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree information Table."
::= { r2Bridge 3 }
r2BrgSTPInfoEntry OBJECT-TYPE
SYNTAX R2BrgSTPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree information Entry"
INDEX { r2Index ,
r2BrgGroupID ,
r2STPIndex }
::= { r2BrgSTPInfo 1 }
R2BrgSTPInfoEntry ::= SEQUENCE {
r2STPIndex INTEGER,
r2STPName DisplayString,
r2STPBridgeID DisplayString,
r2STPHelloTime INTEGER,
r2STPMaxAgingTime INTEGER,
r2STPForwardDelay INTEGER,
r2STPRootCost INTEGER
}
r2STPIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"STP index"
::= { r2BrgSTPInfoEntry 3 }
r2STPName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning tree Name"
::= { r2BrgSTPInfoEntry 4 }
r2STPBridgeID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning tree Bridge Id"
::= { r2BrgSTPInfoEntry 5 }
r2STPHelloTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Hello Time interval"
::= { r2BrgSTPInfoEntry 6 }
r2STPMaxAgingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Maximum Aging Time interval"
::= { r2BrgSTPInfoEntry 7 }
r2STPForwardDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Forward Delay Time interval"
::= { r2BrgSTPInfoEntry 8 }
r2STPRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Post Cost"
::= { r2BrgSTPInfoEntry 9 }
--
-- R2 STP Port Info
--
r2BrgStpPortInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R2BrgStpPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Spanning Tree Port information Table."
::= { r2Bridge 4 }
r2BrgStpPortInfoEntry OBJECT-TYPE
SYNTAX R2BrgStpPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Spanning Tree Port information Entry"
INDEX { r2Index ,
r2BrgGroupID ,
r2StpPortIndex }
::= { r2BrgStpPortInfo 1 }
R2BrgStpPortInfoEntry ::= SEQUENCE {
r2StpPortIndex INTEGER,
r2StpPortName DisplayString,
r2StpState INTEGER,
r2StpPriority INTEGER,
r2StpCost INTEGER,
r2StpEdgePort INTEGER,
r2StpLinkType INTEGER,
r2StpRootPort INTEGER
}
r2StpPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"STP Port Number Index"
::= { r2BrgStpPortInfoEntry 3 }
r2StpPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port Name"
::= { r2BrgStpPortInfoEntry 4 }
r2StpState OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
listen(2),
learn(3),
forward(4),
block(5),
down(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port state"
::= { r2BrgStpPortInfoEntry 5 }
r2StpPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r2BrgStpPortInfoEntry 6 }
r2StpCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r2BrgStpPortInfoEntry 7 }
r2StpEdgePort OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r2BrgStpPortInfoEntry 8 }
r2StpLinkType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
shared(1),
p-to-p(2),
auto(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r2BrgStpPortInfoEntry 9 }
r2StpRootPort OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port root status"
::= { r2BrgStpPortInfoEntry 10 }
--
-- R2 Bridge Add or Delete Interface Table
--
r2BrgAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R2BrgAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or delete interface to bridge group Table."
::= { r2Bridge 5 }
r2BrgAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R2BrgAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or delete interface to bridge group Entry"
INDEX { r2Index }
::= { r2BrgAddDelInterface 1 }
R2BrgAddDelInterfaceEntry ::= SEQUENCE {
r2BrgAddDelBrgName DisplayString,
r2BrgAddDelInterfaceName DisplayString,
r2BrgAddDelInterfaceCMD INTEGER
}
r2BrgAddDelBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Group Name"
::= { r2BrgAddDelInterfaceEntry 2 }
r2BrgAddDelInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1-2/wan1-64/wanX pvc1-16)"
::= { r2BrgAddDelInterfaceEntry 3 }
r2BrgAddDelInterfaceCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add interface to Bridge Mode or (delete)add interface
to router mode"
::= { r2BrgAddDelInterfaceEntry 4 }
--
-- R2 Interface Control Table
--
r2Interface OBJECT IDENTIFIER ::= { router-a-card 4 }
--
-- R2 LAN
--
r2IntfLAN OBJECT IDENTIFIER ::= { r2Interface 1 }
--
-- R2 LAN Config Table
--
r2LanCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2LanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LAN Config Table."
::= { r2IntfLAN 1 }
r2LanCFGEntry OBJECT-TYPE
SYNTAX R2LanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LAN Config Entry"
INDEX { r2Index ,
r2LanIndex }
::= { r2LanCFG 1 }
R2LanCFGEntry ::= SEQUENCE {
r2LanIndex INTEGER,
r2LanIPAddr DisplayString,
r2LanAliasIPAddr1 DisplayString,
r2LanAliasIPAddr2 DisplayString,
r2LanAliasIPAddr3 DisplayString,
r2LanAliasIPAddr4 DisplayString,
r2LanAliasIPAddr5 DisplayString,
r2LanRoutingProtocol INTEGER,
r2LanLayer2Protocol INTEGER,
r2LanSpeed INTEGER,
r2LanInterfaceMode INTEGER,
r2LanInboundPolicy DisplayString,
r2LanOutboundPolicy DisplayString,
r2LanStatus DisplayString
}
r2LanIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
lan2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Index"
::= { r2LanCFGEntry 2 }
r2LanIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 3 }
r2LanAliasIPAddr1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 4 }
r2LanAliasIPAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 5 }
r2LanAliasIPAddr3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 6 }
r2LanAliasIPAddr4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 7 }
r2LanAliasIPAddr5 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2LanCFGEntry 8 }
r2LanRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table)"
::= { r2LanCFGEntry 9 }
r2LanLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
no(0),
ethernet(1),
fast-ethernet(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Layer2 Protocol"
::= { r2LanCFGEntry 10 }
r2LanSpeed OBJECT-TYPE
SYNTAX INTEGER {
no(0),
half-duplex-10M(1),
full-duplex-10M(2),
half-duplex-100M(3),
full-duplex-100M(4),
auto-negotiation(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Speed(10/100Mb ; half/full)"
::= { r2LanCFGEntry 11 }
r2LanInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Interface Mode"
::= { r2LanCFGEntry 12 }
r2LanInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan inbound policy (off to disable access control)"
::= { r2LanCFGEntry 13 }
r2LanOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan outbound policy (off to disable access control)"
::= { r2LanCFGEntry 14 }
r2LanStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Status"
::= { r2LanCFGEntry 15 }
--
-- R2 Add or Delete Lan Alias IP Table
--
r2AddDelAliasIP OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelAliasIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Lan Alias IP Table."
::= { r2IntfLAN 2 }
r2AddDelAliasIPEntry OBJECT-TYPE
SYNTAX R2AddDelAliasIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Lan Alias IP Entry"
INDEX { r2Index }
::= { r2AddDelAliasIP 1 }
R2AddDelAliasIPEntry ::= SEQUENCE {
r2AliasIPLanIndex INTEGER,
r2AliasIPAddr DisplayString,
r2AliasIPAddrCMD INTEGER
}
r2AliasIPLanIndex OBJECT-TYPE
SYNTAX INTEGER{
lan1(1),
lan2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Index"
::= { r2AddDelAliasIPEntry 2 }
r2AliasIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alias IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2AddDelAliasIPEntry 3 }
r2AliasIPAddrCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or Delete Alias IP Address"
::= { r2AddDelAliasIPEntry 4 }
--
-- R2 WAN
--
r2IntfWAN OBJECT IDENTIFIER ::= { r2Interface 2 }
--
-- R2 WAN Config Table
--
r2WanCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface WAN(1-64) Config Table."
::= { r2IntfWAN 1 }
r2WanCFGEntry OBJECT-TYPE
SYNTAX R2WanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface WAN(1-64) Config Entry"
INDEX { r2Index ,
r2WanIndex }
::= { r2WanCFG 1 }
R2WanCFGEntry ::= SEQUENCE {
r2WanIndex INTEGER,
r2WanIPAddr DisplayString,
r2WanRoutingProtocol INTEGER,
r2WanNatNapt INTEGER,
r2WanNumberOfTimeSlots INTEGER,
r2WanLayer2Protocol INTEGER,
r2WanInterfaceMode INTEGER,
r2WanInboundPolicy DisplayString,
r2WanOutboundPolicy DisplayString,
r2WanStatus INTEGER
}
r2WanIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface WAN1-WAN2"
::= { r2WanCFGEntry 2 }
r2WanIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2WanCFGEntry 3 }
r2WanRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table)"
::= { r2WanCFGEntry 4 }
r2WanNatNapt OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
nat(2),
napt(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN NAT/NAPT Function"
::= { r2WanCFGEntry 5 }
r2WanNumberOfTimeSlots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of TimeSlots for this WAN"
::= { r2WanCFGEntry 6 }
r2WanLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
no(0),
ppp(3),
hdlc(4),
frame-relay(5),
cisco-hdlc(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Layer2 Protocol"
::= { r2WanCFGEntry 7 }
r2WanInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Interface Mode"
::= { r2WanCFGEntry 8 }
r2WanInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan inbound policy (off to disable access control)"
::= { r2WanCFGEntry 9 }
r2WanOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan outbound policy (off to disable access control)"
::= { r2WanCFGEntry 10 }
r2WanStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Status"
::= { r2WanCFGEntry 11 }
--
-- R2 WAN Cisco Hdlc Config Table
--
r2WanCiscoHdlc OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanCiscoHdlcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Cisco Hdlc Config Table."
::= { r2IntfWAN 2 }
r2WanCiscoHdlcEntry OBJECT-TYPE
SYNTAX R2WanCiscoHdlcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Cisco Hdlc Config Entry"
INDEX { r2Index ,
r2WanIndex }
::= { r2WanCiscoHdlc 1 }
R2WanCiscoHdlcEntry ::= SEQUENCE {
r2WanChdlcInterval INTEGER,
r2WanChdlcTimeout INTEGER,
r2WanChdlcCMD INTEGER
}
r2WanChdlcInterval OBJECT-TYPE
SYNTAX INTEGER (0 | 1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Keepalive interval (1-3600, default is 10 secs)"
::= { r2WanCiscoHdlcEntry 3 }
r2WanChdlcTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface restart timeout(secs, should be multiple of interval)"
::= { r2WanCiscoHdlcEntry 4 }
r2WanChdlcCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
set(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Cisco Hdlc"
::= { r2WanCiscoHdlcEntry 5 }
--
-- R2 WAN Frame Relay Config Table
--
r2WanFrameRelay OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanFrameRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Frame Relay Config Table."
::= { r2IntfWAN 3 }
r2WanFrameRelayEntry OBJECT-TYPE
SYNTAX R2WanFrameRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Frame Relay Config Entry"
INDEX { r2Index ,
r2WanIndex }
::= { r2WanFrameRelay 1 }
R2WanFrameRelayEntry ::= SEQUENCE {
r2WanFRLMIType INTEGER,
r2WanFRN391 INTEGER,
r2WanFRN392 INTEGER,
r2WanFRN393 INTEGER,
r2WanFRT391 INTEGER
}
r2WanFRLMIType OBJECT-TYPE
SYNTAX INTEGER {
na(0),
q933(1),
ansi(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Relay LMI protocol (ansi/q933)"
::= { r2WanFrameRelayEntry 3 }
r2WanFRN391 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI full-status polling interval (1~255)"
::= { r2WanFrameRelayEntry 4 }
r2WanFRN392 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI error threshold (1~10)"
::= { r2WanFrameRelayEntry 5 }
r2WanFRN393 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI monitored event threshold (1~10)"
::= { r2WanFrameRelayEntry 6 }
r2WanFRT391 OBJECT-TYPE
SYNTAX INTEGER (0 | 5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI link integrity polling interval (5~30)"
::= { r2WanFrameRelayEntry 7 }
--
-- R2 WAN PVC
--
r2WanPVC OBJECT IDENTIFIER ::= { r2IntfWAN 4 }
--
-- R2 WAN PVC Function Table
--
r2WanAddDelPVC OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanAddDelPVCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC Table"
::= { r2WanPVC 1 }
r2WanAddDelPVCEntry OBJECT-TYPE
SYNTAX R2WanAddDelPVCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC Entry"
INDEX { r2Index }
::= { r2WanAddDelPVC 1 }
R2WanAddDelPVCEntry ::= SEQUENCE {
r2PvcWanIndex INTEGER,
r2PvcNum INTEGER,
r2PvcDLCI INTEGER,
r2PvcCIR INTEGER,
r2PvcBc INTEGER,
r2PvcBe INTEGER,
r2PvcQdepth INTEGER,
r2WanPvcCMD INTEGER
}
r2PvcWanIndex OBJECT-TYPE
SYNTAX INTEGER (0 | 1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Wan number (wan1-wan64)"
::= { r2WanAddDelPVCEntry 2 }
r2PvcNum OBJECT-TYPE
SYNTAX INTEGER (0 | 1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC number (pvc1-pvc16)"
::= { r2WanAddDelPVCEntry 3 }
r2PvcDLCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC's DLCI (16~991)"
::= { r2WanAddDelPVCEntry 4 }
r2PvcCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Information Rate (kbps)"
::= { r2WanAddDelPVCEntry 5 }
r2PvcBc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Burst Size (kbits)"
::= { r2WanAddDelPVCEntry 6 }
r2PvcBe OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Excess Burst Size (kbits)"
::= { r2WanAddDelPVCEntry 7 }
r2PvcQdepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max. queue length"
::= { r2WanAddDelPVCEntry 8 }
r2WanPvcCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
add-pvc(1),
delete-pvc(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC for this wan interface"
::= { r2WanAddDelPVCEntry 9 }
--
-- R2 WAN PVC Config Table
--
r2WanPvcCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanPvcCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN PVC Config Table"
::= { r2WanPVC 2 }
r2WanPvcCFGEntry OBJECT-TYPE
SYNTAX R2WanPvcCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN PVC Config Entry"
INDEX { r2Index ,
r2WanIndex ,
r2PvcIndex }
::= { r2WanPvcCFG 1 }
R2WanPvcCFGEntry ::= SEQUENCE {
r2PvcIndex INTEGER,
r2WanPvcState INTEGER,
r2WanPvcIPAddr DisplayString,
r2WanPvcRoutingProtocol INTEGER,
r2WanPvcNatNapt INTEGER,
r2WanPvcInterfaceMode INTEGER,
r2WanPvcDLCI INTEGER,
r2WanPvcCIR INTEGER,
r2WanPvcBc INTEGER,
r2WanPvcBe INTEGER,
r2WanPvcQdepth INTEGER,
r2WanPvcInboundPolicy DisplayString,
r2WanPvcOutboundPolicy DisplayString
}
r2PvcIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PVC number (pvc1-pvc16)"
::= { r2WanPvcCFGEntry 3 }
r2WanPvcState OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN PVC State"
::= { r2WanPvcCFGEntry 4 }
r2WanPvcIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC IP address (xxx.xxx.xxx.xxx/xx)"
::= { r2WanPvcCFGEntry 5 }
r2WanPvcRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table)"
::= { r2WanPvcCFGEntry 6 }
r2WanPvcNatNapt OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
nat(2),
napt(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC NAT/NAPT Function"
::= { r2WanPvcCFGEntry 7 }
r2WanPvcInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN PVC Interface Mode"
::= { r2WanPvcCFGEntry 8 }
r2WanPvcDLCI OBJECT-TYPE
SYNTAX INTEGER (16..991)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC's DLCI (16~991)"
::= { r2WanPvcCFGEntry 9 }
r2WanPvcCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Information Rate (kbps)"
::= { r2WanPvcCFGEntry 10 }
r2WanPvcBc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Burst Size (kbits)"
::= { r2WanPvcCFGEntry 11 }
r2WanPvcBe OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Excess Burst Size (kbits)"
::= { r2WanPvcCFGEntry 12 }
r2WanPvcQdepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max. queue length"
::= { r2WanPvcCFGEntry 13 }
r2WanPvcInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Pvc inbound policy (off to disable access control)"
::= { r2WanPvcCFGEntry 14 }
r2WanPvcOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Pvc outbound policy (off to disable access control)"
::= { r2WanPvcCFGEntry 15 }
--
-- R2 WAN Channel Map
--
r2WanChannelMap OBJECT IDENTIFIER ::= { r2IntfWAN 5 }
--
-- R2 WAN Set Channel Map Control
--
r2WanSetMap OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanSetMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Set Channel Map Table"
::= { r2WanChannelMap 1 }
r2WanSetMapEntry OBJECT-TYPE
SYNTAX R2WanSetMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Set Channel Map Entry"
INDEX { r2Index }
::= { r2WanSetMap 1 }
R2WanSetMapEntry ::= SEQUENCE {
r2MapWanNumber INTEGER,
r2StartTimeSlot INTEGER,
r2ChannelNumber INTEGER,
r2MapCommand INTEGER
}
r2MapWanNumber OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Index(wan1~wan64)"
::= { r2WanSetMapEntry 2 }
r2StartTimeSlot OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set start time slot number"
::= { r2WanSetMapEntry 3 }
r2ChannelNumber OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set channel number"
::= { r2WanSetMapEntry 4 }
r2MapCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1),
set(2),
clrSet(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map Command"
::= { r2WanSetMapEntry 5 }
--
-- R2 WAN Channel Map Info Table
--
r2ChannelMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Channel Map Config Table"
::= { r2WanChannelMap 2 }
r2ChannelMapEntry OBJECT-TYPE
SYNTAX R2ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Channel Map Config Entry"
INDEX { r2Index ,
r2TimeSlotIndex }
::= { r2ChannelMapTable 1 }
R2ChannelMapEntry ::= SEQUENCE {
r2TimeSlotIndex INTEGER,
r2MapToWanNum WanID
}
r2TimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot number"
::= { r2ChannelMapEntry 2 }
r2MapToWanNum OBJECT-TYPE
SYNTAX WanID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot number"
::= { r2ChannelMapEntry 3 }
--
-- R2 WAN QoS Table
--
r2WanQoS OBJECT IDENTIFIER ::= { r2IntfWAN 6 }
--
-- R2 WAN Qos Policy Table
--
r2WanQosPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanQosPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Table."
::= { r2WanQoS 1 }
r2WanQosPolicyEntry OBJECT-TYPE
SYNTAX R2WanQosPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Entry"
INDEX { r2Index ,
r2WanIndex ,
r2WanQosPolicyNumber }
::= { r2WanQosPolicyTable 1 }
R2WanQosPolicyEntry ::= SEQUENCE {
r2WanQosPolicyNumber INTEGER,
r2WanQosPolicySrcIP DisplayString,
r2WanQosPolicyDstIP DisplayString,
r2WanQosPolicyProtocol DisplayString,
r2WanQosPolicyRate DisplayString,
r2WanQosPolicySrcPort DisplayString,
r2WanQosPolicyDstPort DisplayString
}
r2WanQosPolicyNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Qos Policy Number"
::= { r2WanQosPolicyEntry 3 }
r2WanQosPolicySrcIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Source IP/Perfix"
::= { r2WanQosPolicyEntry 4 }
r2WanQosPolicyDstIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Destination IP/Perfix"
::= { r2WanQosPolicyEntry 5 }
r2WanQosPolicyProtocol OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Qos Policy Protocol"
::= { r2WanQosPolicyEntry 6 }
r2WanQosPolicyRate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Rate"
::= { r2WanQosPolicyEntry 7 }
r2WanQosPolicySrcPort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Source Port"
::= { r2WanQosPolicyEntry 8 }
r2WanQosPolicyDstPort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Destination Port"
::= { r2WanQosPolicyEntry 9 }
--
-- R2 WAN Qos Policy Control Table
--
r2WanQosPolicyControl OBJECT IDENTIFIER ::= { r2WanQoS 2 }
--
-- R2 WAN Qos Append and Insert Policy Table
--
r2WanQosAppendAndInsertPolicy OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanQosAppendAndInsertPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append od Insert a traffic control policy Table."
::= { r2WanQosPolicyControl 1 }
r2WanQosAppendAndInsertPolicyEntry OBJECT-TYPE
SYNTAX R2WanQosAppendAndInsertPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append od Insert a traffic control policy Entry"
INDEX { r2Index }
::= { r2WanQosAppendAndInsertPolicy 1 }
R2WanQosAppendAndInsertPolicyEntry ::= SEQUENCE {
r2WanAppInstPolicyWanNum INTEGER (1..64),
r2WanAppInstPolicySrcIP DisplayString (SIZE (0..20)),
r2WanAppInstPolicySrcIPPrefix DisplayString (SIZE (0..2)),
r2WanAppInstPolicyDstIP DisplayString (SIZE (0..20)),
r2WanAppInstPolicyDstIPPrefix DisplayString (SIZE (0..2)),
r2WanAppInstPolicySrcPort DisplayString (SIZE (0..25)),
r2WanAppInstPolicyDstPort DisplayString (SIZE (0..25)),
r2WanAppInstPolicyProtocol DisplayString (SIZE (0..10)),
r2WanAppInstPolicyRate DisplayString (SIZE (0..25)),
r2WanAppInstPolicyRateType INTEGER,
r2WanInstPolicyNum INTEGER (0..32),
r2WanAppInstPolicyCommand INTEGER
}
r2WanAppInstPolicyWanNum OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Number(Wan 1~64)"
::= { r2WanQosAppendAndInsertPolicyEntry 2 }
r2WanAppInstPolicySrcIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source IP(xxx.xxx.xxx.xxx)"
::= { r2WanQosAppendAndInsertPolicyEntry 3 }
r2WanAppInstPolicySrcIPPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source IP Prefix(skip if src_ip is 'any')"
::= { r2WanQosAppendAndInsertPolicyEntry 4 }
r2WanAppInstPolicyDstIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination IP(xxx.xxx.xxx.xxx)"
::= { r2WanQosAppendAndInsertPolicyEntry 5 }
r2WanAppInstPolicyDstIPPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination IP Prefix(skip if dst_ip is 'any')"
::= { r2WanQosAppendAndInsertPolicyEntry 6 }
r2WanAppInstPolicySrcPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source Port(any or min[-max] only for TCP/UDP, (no space before and after '-')"
::= { r2WanQosAppendAndInsertPolicyEntry 7 }
r2WanAppInstPolicyDstPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination Port(any or min[-max] only for TCP/UDP, (no space before and after '-')"
::= { r2WanQosAppendAndInsertPolicyEntry 8 }
r2WanAppInstPolicyProtocol OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Protocol(TCP or UDP or ICMP or Any or 0~255)"
::= { r2WanQosAppendAndInsertPolicyEntry 9 }
r2WanAppInstPolicyRate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Rate(Committed access rate in min[-max] format, (no space before and after '-') )"
::= { r2WanQosAppendAndInsertPolicyEntry 10 }
r2WanAppInstPolicyRateType OBJECT-TYPE
SYNTAX INTEGER {
kbps(1),
mbps(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Rate Type(type of bandwidth for rate in bits per sec)"
::= { r2WanQosAppendAndInsertPolicyEntry 11 }
r2WanInstPolicyNum OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy number before which new policy will be inserted"
::= { r2WanQosAppendAndInsertPolicyEntry 12 }
r2WanAppInstPolicyCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
append(1),
insert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Command"
::= { r2WanQosAppendAndInsertPolicyEntry 13 }
--
-- R2 WAN Qos Delete Policy Table
--
r2WanQosDeletePolicy OBJECT-TYPE
SYNTAX SEQUENCE OF R2WanQosDeletePolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete a traffic control policy Table."
::= { r2WanQosPolicyControl 2 }
r2WanQosDeletePolicyEntry OBJECT-TYPE
SYNTAX R2WanQosDeletePolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete a traffic control policy Entry"
INDEX { r2Index }
::= { r2WanQosDeletePolicy 1 }
R2WanQosDeletePolicyEntry ::= SEQUENCE {
r2WanDelPolicyWanNum INTEGER (1..64),
r2WanDelPolicyNumber INTEGER (1..32),
r2WanDelPolicyCommand INTEGER
}
r2WanDelPolicyWanNum OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Number(Wan 1~64)"
::= { r2WanQosDeletePolicyEntry 2 }
r2WanDelPolicyNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Number(1~32)"
::= { r2WanQosDeletePolicyEntry 3 }
r2WanDelPolicyCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete Policy Command"
::= { r2WanQosDeletePolicyEntry 4 }
--
-- R2 Virtual Interface
--
r2IntfVirtual OBJECT IDENTIFIER ::= { r2Interface 3 }
--
-- R2 Virtual Interface Config
--
r2VirtualIntfCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2VirtualIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Configuration Table."
::= { r2IntfVirtual 1 }
r2VirtualIntfCFGEntry OBJECT-TYPE
SYNTAX R2VirtualIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Configuration Entry"
INDEX { r2Index ,
r2VIntfIndex }
::= { r2VirtualIntfCFG 1 }
R2VirtualIntfCFGEntry ::= SEQUENCE {
r2VIntfIndex INTEGER,
r2VIntfName DisplayString,
r2VIntfRoutingProtocol INTEGER,
r2VIntfLayer2Protocol INTEGER,
r2VIntfInterfaceMode INTEGER,
r2VIntfInboundPolicy DisplayString,
r2VIntfOutboundPolicy DisplayString,
r2VIntfStatus INTEGER
}
r2VIntfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual interface index"
::= { r2VirtualIntfCFGEntry 2 }
r2VIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual interface name"
::= { r2VirtualIntfCFGEntry 3 }
r2VIntfRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table)"
::= { r2VirtualIntfCFGEntry 4 }
r2VIntfLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
ppp(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Layer2 Protocol"
::= { r2VirtualIntfCFGEntry 5 }
r2VIntfInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Mode of Virtual Interface"
::= { r2VirtualIntfCFGEntry 6 }
r2VIntfInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface inbound policy (off to disable access control)"
::= { r2VirtualIntfCFGEntry 7 }
r2VIntfOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface outbound policy (off to disable access control)"
::= { r2VirtualIntfCFGEntry 8 }
r2VIntfStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Status"
::= { r2VirtualIntfCFGEntry 9 }
--
-- R2 Policy
--
r2Policy OBJECT IDENTIFIER ::= { router-a-card 5 }
--
-- R2 Filter Info
--
r2FilterInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R2FilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"filter information Table"
::= { r2Policy 1 }
r2FilterInfoEntry OBJECT-TYPE
SYNTAX R2FilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"filter information Entry"
INDEX { r2Index ,
r2FilterIndex ,
r2RuleIndex }
::= { r2FilterInfo 1 }
R2FilterInfoEntry ::= SEQUENCE {
r2FilterIndex INTEGER,
r2RuleIndex INTEGER,
r2FilterName DisplayString,
r2FilterAction INTEGER,
r2FilterSrcAddr DisplayString,
r2FilterDestAddr DisplayString,
r2FilterProtocol INTEGER,
r2FilterPortLow INTEGER,
r2FilterPortHigh INTEGER
}
r2FilterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Filter List Index "
::= { r2FilterInfoEntry 2 }
r2RuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"filter rule index"
::= { r2FilterInfoEntry 3 }
r2FilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"filter list Name"
::= { r2FilterInfoEntry 4 }
r2FilterAction OBJECT-TYPE
SYNTAX INTEGER{
deny(1),
permit(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Filter action"
::= { r2FilterInfoEntry 5 }
r2FilterSrcAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"source address of filter action (xx.xx.xx.xx/xx)"
::= { r2FilterInfoEntry 6 }
r2FilterDestAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"destination address of filter action (xx.xx.xx.xx/xx)"
::= { r2FilterInfoEntry 7 }
r2FilterProtocol OBJECT-TYPE
SYNTAX INTEGER{
tcp(1),
udp(2),
icmp(3),
any(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"protocol of filter action"
::= { r2FilterInfoEntry 8 }
r2FilterPortLow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low port of the port range for TCP/UDP"
::= { r2FilterInfoEntry 9 }
r2FilterPortHigh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"High port of the port range for TCP/UDP"
::= { r2FilterInfoEntry 10 }
--
-- R2 Mac Filter Info
--
r2MacFilterInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R2MacFilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Mac filter information Table"
::= { r2Policy 2 }
r2MacFilterInfoEntry OBJECT-TYPE
SYNTAX R2MacFilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Mac filter information Entry"
INDEX { r2Index ,
r2MacFilterIndex ,
r2MacFilterRuleIndex }
::= { r2MacFilterInfo 1 }
R2MacFilterInfoEntry ::= SEQUENCE {
r2MacFilterIndex INTEGER,
r2MacFilterRuleIndex INTEGER,
r2MacFilterName DisplayString,
r2MacFilterMacAddress DisplayString
}
r2MacFilterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter List Index "
::= { r2MacFilterInfoEntry 2 }
r2MacFilterRuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MAc Filter rule index"
::= { r2MacFilterInfoEntry 3 }
r2MacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter list Name"
::= { r2MacFilterInfoEntry 4 }
r2MacFilterMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter Mac Address"
::= { r2MacFilterInfoEntry 5 }
--
-- R2 Filter Control
--
r2FilterControl OBJECT IDENTIFIER ::= { r2Policy 3 }
--
-- R2 Create & Destroy Filter list Table
--
r2CreateDestroyFilter OBJECT-TYPE
SYNTAX SEQUENCE OF R2CreateDestroyFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Filter List Table"
::= { r2FilterControl 1 }
r2CreateDestroyFilterEntry OBJECT-TYPE
SYNTAX R2CreateDestroyFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Filter List Entry"
INDEX { r2Index }
::= { r2CreateDestroyFilter 1 }
R2CreateDestroyFilterEntry ::= SEQUENCE {
r2CreDesFilterName DisplayString,
r2CreDesFilterCMD INTEGER
}
r2CreDesFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filter List Name"
::= { r2CreateDestroyFilterEntry 2 }
r2CreDesFilterCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
create-filter(1),
destroy-filter(2),
create-mac-filter(3),
destroy-mac-filter(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Filter List Command"
::= { r2CreateDestroyFilterEntry 3 }
--
-- R2 Add Filter Rule
--
r2AddFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append filter rule Table"
::= { r2FilterControl 2 }
r2AddFilterRuleEntry OBJECT-TYPE
SYNTAX R2AddFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append filter rule Entry"
INDEX { r2Index }
::= { r2AddFilterRule 1 }
R2AddFilterRuleEntry ::= SEQUENCE {
r2AddFilterName DisplayString,
r2AddFilterAction INTEGER,
r2AddFilterSrcAddr DisplayString,
r2AddFilterDestAddr DisplayString,
r2AddFilterProtocol INTEGER,
r2AddFilterPortLow INTEGER,
r2AddFilterPortHigh INTEGER,
r2AddFilterRuleCMD INTEGER
}
r2AddFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filter List Name"
::= { r2AddFilterRuleEntry 2 }
r2AddFilterAction OBJECT-TYPE
SYNTAX INTEGER{
deny(1),
permit(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Filter action"
::= { r2AddFilterRuleEntry 3 }
r2AddFilterSrcAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"source address of filter action (xx.xx.xx.xx/xx)"
::= { r2AddFilterRuleEntry 4 }
r2AddFilterDestAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"destination address of filter action (xx.xx.xx.xx/xx)"
::= { r2AddFilterRuleEntry 5 }
r2AddFilterProtocol OBJECT-TYPE
SYNTAX INTEGER{
tcp(1),
udp(2),
icmp(3),
any(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"protocol of filter action"
::= { r2AddFilterRuleEntry 6 }
r2AddFilterPortLow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low port of the port range for TCP/UDP"
::= { r2AddFilterRuleEntry 7 }
r2AddFilterPortHigh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"High port of the port range for TCP/UDP"
::= { r2AddFilterRuleEntry 8 }
r2AddFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
append(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Append Filter rule"
::= { r2AddFilterRuleEntry 9 }
--
-- R2 Add Mac Filter Rule
--
r2AddMacFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append Mac filter rule Table"
::= { r2FilterControl 3 }
r2AddMacFilterRuleEntry OBJECT-TYPE
SYNTAX R2AddMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append Mac filter rule Entry"
INDEX { r2Index }
::= { r2AddMacFilterRule 1 }
R2AddMacFilterRuleEntry ::= SEQUENCE {
r2AddMacFilterName DisplayString,
r2AddMacFilterMacAddr DisplayString,
r2AddMacFilterRuleCMD INTEGER
}
r2AddMacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mac Filter List Name"
::= { r2AddMacFilterRuleEntry 2 }
r2AddMacFilterMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mac Filter Mac address"
::= { r2AddMacFilterRuleEntry 3 }
r2AddMacFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
append(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Append Mac Filter rule"
::= { r2AddMacFilterRuleEntry 4 }
--
-- R2 Delete Filter Rule
--
r2DelFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R2DelFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete filter rule Table"
::= { r2FilterControl 4 }
r2DelFilterRuleEntry OBJECT-TYPE
SYNTAX R2DelFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete filter rule Entry"
INDEX { r2Index }
::= { r2DelFilterRule 1 }
R2DelFilterRuleEntry ::= SEQUENCE {
r2DelFilterName DisplayString,
r2DelStartIndex INTEGER,
r2DelEndIndex INTEGER,
r2DelFilterRuleCMD INTEGER
}
r2DelFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"filter list Name"
::= { r2DelFilterRuleEntry 2 }
r2DelStartIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"start index of list which will be deleted"
::= { r2DelFilterRuleEntry 3 }
r2DelEndIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"end index of list which will be deleted"
::= { r2DelFilterRuleEntry 4 }
r2DelFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"delete filter rule command"
::= { r2DelFilterRuleEntry 5 }
--
-- R2 Delete Mac Filter Rule
--
r2DelMacFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R2DelMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete Mac filter rule Table"
::= { r2FilterControl 5 }
r2DelMacFilterRuleEntry OBJECT-TYPE
SYNTAX R2DelMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete Mac filter rule Entry"
INDEX { r2Index }
::= { r2DelMacFilterRule 1 }
R2DelMacFilterRuleEntry ::= SEQUENCE {
r2DelMacFilterName DisplayString,
r2DelMacFilterMacAddr DisplayString,
r2DelMacFilterRuleCMD INTEGER
}
r2DelMacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac filter list Name"
::= { r2DelMacFilterRuleEntry 2 }
r2DelMacFilterMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac address"
::= { r2DelMacFilterRuleEntry 3 }
r2DelMacFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"delete mac filter rule command"
::= { r2DelMacFilterRuleEntry 4 }
--
-- R2 Route
--
r2Route OBJECT IDENTIFIER ::= { router-a-card 6 }
--
-- R2 Static Route Table
--
r2StaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Static Route Table"
::= { r2Route 1 }
r2StaticRouteEntry OBJECT-TYPE
SYNTAX R2StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Static Route Entry"
INDEX { r2Index ,
r2RouteIndex }
::= { r2StaticRouteTable 1 }
R2StaticRouteEntry ::= SEQUENCE {
r2RouteIndex INTEGER,
r2StaticRouteNetAddr DisplayString,
r2StaticRouteNetMask DisplayString,
r2StaticRouteGatewayAddr DisplayString,
r2StaticRouteInterface DisplayString
}
r2RouteIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"routing table entry index"
::= { r2StaticRouteEntry 2 }
r2StaticRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route net Address"
::= { r2StaticRouteEntry 3 }
r2StaticRouteNetMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route net mask"
::= { r2StaticRouteEntry 4 }
r2StaticRouteGatewayAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route gateway Address"
::= { r2StaticRouteEntry 5 }
r2StaticRouteInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route output interface"
::= { r2StaticRouteEntry 6 }
--
-- R2 Add Static Route
--
r2AddStaticRoute OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add static route Table"
::= { r2Route 2 }
r2AddStaticRouteEntry OBJECT-TYPE
SYNTAX R2AddStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add static route Entry"
INDEX { r2Index }
::= { r2AddStaticRoute 1 }
R2AddStaticRouteEntry ::= SEQUENCE {
r2AddRouteNetAddr DisplayString,
r2AddRouteGatewayAddr DisplayString,
r2AddRouteInterface DisplayString,
r2AddSataicRouteCMD INTEGER
}
r2AddRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route net Address(xxx.xxx.xxx.xxx/xx)"
::= { r2AddStaticRouteEntry 2 }
r2AddRouteGatewayAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route gateway Address(xxx.xxx.xxx.xxx)"
::= { r2AddStaticRouteEntry 3 }
r2AddRouteInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route output interface(lan1~2/wan1~wan64/wanX pvc1-16/brg_group)"
::= { r2AddStaticRouteEntry 4 }
r2AddSataicRouteCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" add static route "
::= { r2AddStaticRouteEntry 5 }
--
-- R2 Delete Static Route
--
r2DelStaticRoute OBJECT-TYPE
SYNTAX SEQUENCE OF R2DelStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete static route Table"
::= { r2Route 3 }
r2DelStaticRouteEntry OBJECT-TYPE
SYNTAX R2DelStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete static route Entry"
INDEX { r2Index }
::= { r2DelStaticRoute 1 }
R2DelStaticRouteEntry ::= SEQUENCE {
r2DelRouteNetAddr DisplayString,
r2DelSataicRouteCMD INTEGER
}
r2DelRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route net Address(xxx.xxx.xxx.xxx/xx)"
::= { r2DelStaticRouteEntry 2 }
r2DelSataicRouteCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete static route"
::= { r2DelStaticRouteEntry 3 }
--
-- R2 OSPF
--
r2OSPF OBJECT IDENTIFIER ::= { r2Route 4 }
--
-- R2 OSPF General Table
--
r2OspfGereralTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2OspfGereralEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Route OSPF General Config Table"
::= { r2OSPF 1 }
r2OspfGereralEntry OBJECT-TYPE
SYNTAX R2OspfGereralEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Route OSPF General Config Entry"
INDEX { r2Index }
::= { r2OspfGereralTable 1 }
R2OspfGereralEntry ::= SEQUENCE {
r2OspfRedistribute DisplayString (SIZE (1..50)),
r2OspfRouterID DisplayString (SIZE (1..20))
}
r2OspfRedistribute OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..50))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Redistributes (kernel | static | connected | rip | default | none)"
::= { r2OspfGereralEntry 2 }
r2OspfRouterID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address(xxx.xxx.xxx.xxx) that identifies this OSPF router"
::= { r2OspfGereralEntry 3 }
--
-- R2 OSPF Area
--
r2OspfArea OBJECT IDENTIFIER ::= { r2OSPF 2 }
--
-- R2 OSPF Area Config
--
r2OspfAreaCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2OspfAreaCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Area Config"
::= { r2OspfArea 1 }
r2OspfAreaCFGEntry OBJECT-TYPE
SYNTAX R2OspfAreaCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Area Config Entry"
INDEX { r2Index ,
r2OspfAreaCfgIndex }
::= { r2OspfAreaCFG 1 }
R2OspfAreaCFGEntry ::= SEQUENCE {
r2OspfAreaCfgIndex INTEGER,
r2OspfAreaCfgAreaID INTEGER,
r2OspfAreaCfgAuthenticationType INTEGER,
r2OspfAreaCfgAreaType INTEGER,
r2OspfAreaCfgCost INTEGER (0..16777215)
}
r2OspfAreaCfgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OSPF Area Config Index"
::= { r2OspfAreaCFGEntry 2 }
r2OspfAreaCfgAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OSPF Area Config Area ID"
::= { r2OspfAreaCFGEntry 3 }
r2OspfAreaCfgAuthenticationType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
password(2),
md5(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication for an OSPF area"
::= { r2OspfAreaCFGEntry 4 }
r2OspfAreaCfgAreaType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
stub(2),
stub-no-summary(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Designates an area as a stub area"
::= { r2OspfAreaCFGEntry 5 }
r2OspfAreaCfgCost OBJECT-TYPE
SYNTAX INTEGER (0..16777215)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Assign a specific cost to the default summary route used"
::= { r2OspfAreaCFGEntry 6 }
--
-- R2 OSPF Add & Delete Area
--
r2OspfAddDelArea OBJECT-TYPE
SYNTAX SEQUENCE OF R2OspfAddDelAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area"
::= { r2OspfArea 2 }
r2OspfAddDelAreaEntry OBJECT-TYPE
SYNTAX R2OspfAddDelAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area Entry"
INDEX { r2Index }
::= { r2OspfAddDelArea 1 }
R2OspfAddDelAreaEntry ::= SEQUENCE {
r2OspfAddDelAreaID INTEGER,
r2OspfAddDelAreaCommand INTEGER
}
r2OspfAddDelAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area ID"
::= { r2OspfAddDelAreaEntry 2 }
r2OspfAddDelAreaCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area ID Command"
::= { r2OspfAddDelAreaEntry 3 }
--
-- R2 OSPF Interface Table
--
r2OspfInterface OBJECT IDENTIFIER ::= { r2OSPF 3 }
--
-- R2 OSPF Interface Config Table
--
r2OspfIntfCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2OspfIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Config"
::= { r2OspfInterface 1 }
r2OspfIntfCFGEntry OBJECT-TYPE
SYNTAX R2OspfIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Config Entry"
INDEX { r2Index ,
r2OspfIntfIndex }
::= { r2OspfIntfCFG 1 }
R2OspfIntfCFGEntry ::= SEQUENCE {
r2OspfIntfIndex INTEGER,
r2OspfIntfName DisplayString (SIZE (0..20)),
r2OspfIntfAdminStatus INTEGER,
r2OspfIntfAreaID INTEGER,
r2OspfIntfNetworkType INTEGER,
r2OspfIntfLinkCost INTEGER (1..65535),
r2OspfIntfTransmitDelay INTEGER (1..65535),
r2OspfIntfRouterPriority INTEGER (0..255),
r2OspfIntfHelloInterval INTEGER (1..65535),
r2OspfIntfRouterDeadInterval INTEGER (1..65535),
r2OspfIntfRetransmitInterval INTEGER (1..65535),
r2OspfIntfAuthMD5KeyID-Key DisplayString (SIZE (0..20)),
r2OspfIntfAuthPasswordTextKey DisplayString (SIZE (0..8))
}
r2OspfIntfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Index"
::= { r2OspfIntfCFGEntry 2 }
r2OspfIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name(Lan1~2/Wan1~64/Wanxx Pvc1~16)"
::= { r2OspfIntfCFGEntry 3 }
r2OspfIntfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
dsiable(1),
enable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The OSPF interface's administrative status"
::= { r2OspfIntfCFGEntry 4 }
r2OspfIntfAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 32-bit integer uniquely identifying the area to which the interface connects."
::= { r2OspfIntfCFGEntry 5 }
r2OspfIntfNetworkType OBJECT-TYPE
SYNTAX INTEGER {
broadcast(1),
point-to-point(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The OSPF interface type."
::= { r2OspfIntfCFGEntry 6 }
r2OspfIntfLinkCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Explicitly specify the link cost of sending a packet"
::= { r2OspfIntfCFGEntry 7 }
r2OspfIntfTransmitDelay OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for InfTransDelay value."
::= { r2OspfIntfCFGEntry 8 }
r2OspfIntfRouterPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RouterPriority integer value."
::= { r2OspfIntfCFGEntry 9 }
r2OspfIntfHelloInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds between hello packets sent."
::= { r2OspfIntfCFGEntry 10 }
r2OspfIntfRouterDeadInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for RouterDeadInterval timer."
::= { r2OspfIntfCFGEntry 11 }
r2OspfIntfRetransmitInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for RxmtInterval timer value."
::= { r2OspfIntfCFGEntry 12 }
r2OspfIntfAuthMD5KeyID-Key OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface MD5 Authentication KeyID/Key(KeyID:1~255, Key:up to 16 chars)"
::= { r2OspfIntfCFGEntry 13 }
r2OspfIntfAuthPasswordTextKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Password Authentication Key"
::= { r2OspfIntfCFGEntry 14 }
--
-- R2 OSPF Interface Admin Setup Table
--
r2OspfIntfAdminSetup OBJECT-TYPE
SYNTAX SEQUENCE OF R2OspfIntfAdminSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Admin Setup Table"
::= { r2OspfInterface 2 }
r2OspfIntfAdminSetupEntry OBJECT-TYPE
SYNTAX R2OspfIntfAdminSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Admin Setup Entry"
INDEX { r2Index }
::= { r2OspfIntfAdminSetup 1 }
R2OspfIntfAdminSetupEntry ::= SEQUENCE {
r2OspfIntfAdminSetupIntfName DisplayString (SIZE (0..20)),
r2OspfIntfAdminSetupAreaID INTEGER,
r2OspfIntfAdminSetupCMD INTEGER
}
r2OspfIntfAdminSetupIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1~2/wan1~64/wanXX pvcXX)"
::= { r2OspfIntfAdminSetupEntry 2 }
r2OspfIntfAdminSetupAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface OSPF Area ID"
::= { r2OspfIntfAdminSetupEntry 3 }
r2OspfIntfAdminSetupCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0),
disable-intf-ospf(1),
enable-intf-ospf(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface OSPF Admin Setup Command(Disable/Enable)"
::= { r2OspfIntfAdminSetupEntry 4 }
--
-- R2 NAT
--
r2NAT OBJECT IDENTIFIER ::= { router-a-card 7 }
--
-- R2 NAT Interface Mode
--
r2NatIFMode OBJECT-TYPE
SYNTAX SEQUENCE OF R2NatIFModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT interface mode status Table"
::= { r2NAT 1 }
r2NatIFModeEntry OBJECT-TYPE
SYNTAX R2NatIFModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT interface mode status Entry"
INDEX { r2Index ,
r2NatIFIndex }
::= { r2NatIFMode 1 }
R2NatIFModeEntry ::= SEQUENCE {
r2NatIFIndex INTEGER,
r2NatIFName DisplayString,
r2NatMode INTEGER
}
r2NatIFIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT index"
::= { r2NatIFModeEntry 2 }
r2NatIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r2NatIFModeEntry 3 }
r2NatMode OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
nat(2),
napt(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT mode of interface"
::= { r2NatIFModeEntry 4 }
--
-- R2 NAT IP Pool
--
r2NatIPPool OBJECT-TYPE
SYNTAX SEQUENCE OF R2NatIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP Pool Table"
::= { r2NAT 2 }
r2NatIPPoolEntry OBJECT-TYPE
SYNTAX R2NatIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP Pool Entry"
INDEX { r2Index ,
r2NatIFIndex ,
r2NatPoolIndex }
::= { r2NatIPPool 1 }
R2NatIPPoolEntry ::= SEQUENCE {
r2NatPoolIndex INTEGER,
r2NatPoolIFName DisplayString,
r2NatStartAddress DisplayString,
r2NatEndAddress DisplayString
}
r2NatPoolIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Pool index"
::= { r2NatIPPoolEntry 3 }
r2NatPoolIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanX pvc1-16)"
::= { r2NatIPPoolEntry 4 }
r2NatStartAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT start address"
::= { r2NatIPPoolEntry 5 }
r2NatEndAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT end address"
::= { r2NatIPPoolEntry 6 }
--
-- R2 NAT Add or Delete IP Pool
--
r2NatAddDelIPPool OBJECT-TYPE
SYNTAX SEQUENCE OF R2NatAddDelIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete NAT IP Pool Table"
::= { r2NAT 3 }
r2NatAddDelIPPoolEntry OBJECT-TYPE
SYNTAX R2NatAddDelIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete NAT IP Pool Entry"
INDEX { r2Index }
::= { r2NatAddDelIPPool 1 }
R2NatAddDelIPPoolEntry ::= SEQUENCE {
r2NatAddDelPoolIFName DisplayString,
r2NatAddDelPoolIndex INTEGER,
r2NatAddDelStartAddr DisplayString,
r2NatAddDelEndAddr DisplayString,
r2NatAddDelIPPoolCMD INTEGER
}
r2NatAddDelPoolIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanx pvc1-16)"
::= { r2NatAddDelIPPoolEntry 2 }
r2NatAddDelPoolIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete IP Pool index"
::= { r2NatAddDelIPPoolEntry 3 }
r2NatAddDelStartAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT start address(xxx.xxx.xxx.xxx)"
::= { r2NatAddDelIPPoolEntry 4 }
r2NatAddDelEndAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT end address(xxx.xxx.xxx.xxx)"
::= { r2NatAddDelIPPoolEntry 5 }
r2NatAddDelIPPoolCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete IP Pool command"
::= { r2NatAddDelIPPoolEntry 6 }
--
-- R2 NAT IP Static
--
r2NatIPStatic OBJECT-TYPE
SYNTAX SEQUENCE OF R2NatIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP static status Table"
::= { r2NAT 4 }
r2NatIPStaticEntry OBJECT-TYPE
SYNTAX R2NatIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP static status Entry"
INDEX { r2Index ,
r2NatIFIndex ,
r2NatIPStaticIndex }
::= { r2NatIPStatic 1 }
R2NatIPStaticEntry ::= SEQUENCE {
r2NatIPStaticIndex INTEGER,
r2NatIPStaticIFName DisplayString,
r2NatIPStaticPublicAddr DisplayString,
r2NatIPStaticPrivateAddr DisplayString
}
r2NatIPStaticIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static index"
::= { r2NatIPStaticEntry 2 }
r2NatIPStaticIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface name(wan1-64/wanx pvc1-16)"
::= { r2NatIPStaticEntry 3 }
r2NatIPStaticPublicAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static public Address"
::= { r2NatIPStaticEntry 4 }
r2NatIPStaticPrivateAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static private Address"
::= { r2NatIPStaticEntry 5 }
--
-- R2 NAT Add or Delete IP Static
--
r2NatAddDelIPStatic OBJECT-TYPE
SYNTAX SEQUENCE OF R2NatAddDelIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static Table"
::= { r2NAT 5 }
r2NatAddDelIPStaticEntry OBJECT-TYPE
SYNTAX R2NatAddDelIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static Entry"
INDEX { r2Index }
::= { r2NatAddDelIPStatic 1 }
R2NatAddDelIPStaticEntry ::= SEQUENCE {
r2NatAddDelIPStaticIFName DisplayString,
r2NatAddDelPublicAddr DisplayString,
r2NatAddDelPrivateAddr DisplayString,
r2NatAddDelIPStaticCMD INTEGER
}
r2NatAddDelIPStaticIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanx pvc1-16)"
::= { r2NatAddDelIPStaticEntry 2 }
r2NatAddDelPublicAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP static public Address(xxx.xxx.xxx.xxx)"
::= { r2NatAddDelIPStaticEntry 3 }
r2NatAddDelPrivateAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP static private Address(xxx.xxx.xxx.xxx)"
::= { r2NatAddDelIPStaticEntry 4 }
r2NatAddDelIPStaticCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static command"
::= { r2NatAddDelIPStaticEntry 5 }
--
-- R2 NAPT Port Forwarding
--
r2NaptPortForwarding OBJECT-TYPE
SYNTAX SEQUENCE OF R2NaptPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding Table"
::= { r2NAT 6 }
r2NaptPortForwardingEntry OBJECT-TYPE
SYNTAX R2NaptPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding Entry"
INDEX { r2Index ,
r2NaptIFIndex ,
r2NaptPortFwdIndex }
::= { r2NaptPortForwarding 1 }
R2NaptPortForwardingEntry ::= SEQUENCE {
r2NaptIFIndex INTEGER,
r2NaptPortFwdIndex INTEGER,
r2NaptIFName DisplayString,
r2NaptPortFwdName DisplayString,
r2NaptPortFwdStartPort INTEGER,
r2NaptPortFwdEndPort INTEGER,
r2NaptPortFwdServerIP DisplayString
}
r2NaptIFIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface index"
::= { r2NaptPortForwardingEntry 2 }
r2NaptPortFwdIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding entry index"
::= { r2NaptPortForwardingEntry 3 }
r2NaptIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r2NaptPortForwardingEntry 4 }
r2NaptPortFwdName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NAPT entry name"
::= { r2NaptPortForwardingEntry 5 }
r2NaptPortFwdStartPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Start Port number"
::= { r2NaptPortForwardingEntry 6 }
r2NaptPortFwdEndPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"End Port number"
::= { r2NaptPortForwardingEntry 7 }
r2NaptPortFwdServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the service(xxx.xxx.xxx.xxx)"
::= { r2NaptPortForwardingEntry 8 }
--
-- R2 NAPT Add or Delete Port Forwarding
--
r2NaptAddDelPortForwarding OBJECT-TYPE
SYNTAX SEQUENCE OF R2NaptAddDelPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Add or Delete Port Forwarding Table"
::= { r2NAT 7 }
r2NaptAddDelPortForwardingEntry OBJECT-TYPE
SYNTAX R2NaptAddDelPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Add or Delete Port Forwarding Entry"
INDEX { r2Index }
::= { r2NaptAddDelPortForwarding 1 }
R2NaptAddDelPortForwardingEntry ::= SEQUENCE {
r2NaptAddDelIFName DisplayString,
r2NaptAddDelName DisplayString,
r2NaptAddDelStartPort INTEGER,
r2NaptAddDelEndPort INTEGER,
r2NaptAddDelServerIP DisplayString,
r2NaptAddDelPortFwdCMD INTEGER
}
r2NaptAddDelIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r2NaptAddDelPortForwardingEntry 2 }
r2NaptAddDelName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NAPT entry name"
::= { r2NaptAddDelPortForwardingEntry 3 }
r2NaptAddDelStartPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Start Port number"
::= { r2NaptAddDelPortForwardingEntry 4 }
r2NaptAddDelEndPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"End Port number"
::= { r2NaptAddDelPortForwardingEntry 5 }
r2NaptAddDelServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the service(xxx.xxx.xxx.xxx)"
::= { r2NaptAddDelPortForwardingEntry 6 }
r2NaptAddDelPortFwdCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAPT add or delete port forwarding command"
::= { r2NaptAddDelPortForwardingEntry 7 }
--
-- R2 VLAN
--
r2VLAN OBJECT IDENTIFIER ::= { router-a-card 8 }
--
-- R2 VLAN State
--
r2VlanState OBJECT-TYPE
SYNTAX SEQUENCE OF R2VlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Table"
::= { r2VLAN 1 }
r2VlanStateEntry OBJECT-TYPE
SYNTAX R2VlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Entry"
INDEX { r2Index ,
r2BrgGroupID }
::= { r2VlanState 1 }
R2VlanStateEntry ::= SEQUENCE {
r2VlanBrgName DisplayString,
r2VlanEnable INTEGER,
r2VlanMgmtVID INTEGER,
r2VlanRegenCRC INTEGER
}
r2VlanBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2VlanStateEntry 3 }
r2VlanEnable OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan state enable/disable"
::= { r2VlanStateEntry 4 }
r2VlanMgmtVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN ID for the bridge management interface"
::= { r2VlanStateEntry 5 }
r2VlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable CRC regenerating on WAN interfaces for VLAN frames"
::= { r2VlanStateEntry 6 }
--
-- R2 VLAN Table
--
r2VlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2VlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan Table"
::= { r2VLAN 2 }
r2VlanTableEntry OBJECT-TYPE
SYNTAX R2VlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan Table Tag Member Entry"
INDEX { r2Index ,
r2BrgGroupID ,
r2VlanID ,
r2VlanTableIndex }
::= { r2VlanTable 1 }
R2VlanTableEntry ::= SEQUENCE {
r2VlanID INTEGER,
r2VlanTableIndex INTEGER,
r2VlanTagMember DisplayString,
r2VlanUnTagMember DisplayString
}
r2VlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan Index"
::= { r2VlanTableEntry 3 }
r2VlanTableIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan Tag Index"
::= { r2VlanTableEntry 4 }
r2VlanTagMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r2VlanTableEntry 5 }
r2VlanUnTagMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r2VlanTableEntry 6 }
--
-- R2 VLAN Table Control
--
r2VlanTableControl OBJECT IDENTIFIER ::= { r2VLAN 3 }
--
-- R2 VLAN Create and Destroy VLAN
--
r2VlanCreateDestroyVlan OBJECT-TYPE
SYNTAX SEQUENCE OF R2VlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy vlan Table"
::= { r2VlanTableControl 1 }
r2VlanCreateDestroyVlanEntry OBJECT-TYPE
SYNTAX R2VlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy vlan Entry"
INDEX { r2Index }
::= { r2VlanCreateDestroyVlan 1 }
R2VlanCreateDestroyVlanEntry ::= SEQUENCE {
r2VlanCreateDestroyBrgName DisplayString,
r2VlanCreateDestroyVidNum INTEGER,
r2ValnCreateDestroyCMD INTEGER
}
r2VlanCreateDestroyBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2VlanCreateDestroyVlanEntry 2 }
r2VlanCreateDestroyVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan VID"
::= { r2VlanCreateDestroyVlanEntry 3 }
r2ValnCreateDestroyCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
create-vlan(1),
destroy-vlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create and destroy vlan command"
::= { r2VlanCreateDestroyVlanEntry 4 }
--
-- R2 VLAN Add and Delete Port
--
r2VlanAddDelPort OBJECT-TYPE
SYNTAX SEQUENCE OF R2VlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan add and del port Table"
::= { r2VlanTableControl 2 }
r2VlanAddDelPortEntry OBJECT-TYPE
SYNTAX R2VlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan add and del port Entry"
INDEX { r2Index }
::= { r2VlanAddDelPort 1 }
R2VlanAddDelPortEntry ::= SEQUENCE {
r2VlanAddDelPortBrgName DisplayString,
r2VlanAddDelPortVidNum INTEGER,
r2VlanAddDelPortTag INTEGER,
r2VlanAddDelPortInterface DisplayString,
r2VlanAddDelPortCMD INTEGER
}
r2VlanAddDelPortBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2VlanAddDelPortEntry 2 }
r2VlanAddDelPortVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan VID"
::= { r2VlanAddDelPortEntry 3 }
r2VlanAddDelPortTag OBJECT-TYPE
SYNTAX INTEGER{
untag(1),
tag(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r2VlanAddDelPortEntry 4 }
r2VlanAddDelPortInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name (lan1~2/wan1~wan64/wanX pvc1-16)"
::= { r2VlanAddDelPortEntry 5 }
r2VlanAddDelPortCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add-port-to-vlan(1),
delete-port-from-vlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan add and delete port command"
::= { r2VlanAddDelPortEntry 6 }
--
-- R2 VLAN Port Table
--
r2VlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2VlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Table"
::= { r2VLAN 4 }
r2VlanPortTableEntry OBJECT-TYPE
SYNTAX R2VlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Entry"
INDEX { r2Index ,
r2VlanPortIndex }
::= { r2VlanPortTable 1 }
R2VlanPortTableEntry ::= SEQUENCE {
r2VlanPortIndex INTEGER,
r2VlanPortIFName DisplayString,
r2VlanPortPVID INTEGER,
r2VlanPortFrameType INTEGER,
r2VlanPortIngressFilter INTEGER
}
r2VlanPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan port index"
::= { r2VlanPortTableEntry 2 }
r2VlanPortIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port type(lan1~2/wan1~wan64/wanX pvc1-16)"
::= { r2VlanPortTableEntry 3 }
r2VlanPortPVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface PVID"
::= { r2VlanPortTableEntry 4 }
r2VlanPortFrameType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
all(1),
tag-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the acceptable frame type"
::= { r2VlanPortTableEntry 5 }
r2VlanPortIngressFilter OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable ingress filtering"
::= { r2VlanPortTableEntry 6 }
--
-- R2 DHCP
--
r2DHCP OBJECT IDENTIFIER ::= { router-a-card 9 }
--
-- R2 DHCP Server
--
r2DHCPServer OBJECT IDENTIFIER ::= { r2DHCP 1 }
--
-- R2 DHCP Server Config
--
r2DhcpServerCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpServerCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Server Config Table"
::= { r2DHCPServer 1 }
r2DhcpServerCFGEntry OBJECT-TYPE
SYNTAX R2DhcpServerCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Server Config Entry"
INDEX { r2Index }
::= { r2DhcpServerCFG 1 }
R2DhcpServerCFGEntry ::= SEQUENCE {
r2DhcpServer INTEGER,
r2DhcpServerInterface DisplayString,
r2DhcpServerBridgeMgmt DisplayString
}
r2DhcpServer OBJECT-TYPE
SYNTAX INTEGER{
na(0),
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP function disable/enable"
::= { r2DhcpServerCFGEntry 2 }
r2DhcpServerInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP interface config"
::= { r2DhcpServerCFGEntry 3 }
r2DhcpServerBridgeMgmt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP bridge mgmt"
::= { r2DhcpServerCFGEntry 4 }
--
-- R2 Add or Delete DHCP Server Interface
--
r2DhcpServerAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpServerAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP interface Table"
::= { r2DHCPServer 2 }
r2DhcpServerAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R2DhcpServerAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP interface Entry"
INDEX { r2Index }
::= { r2DhcpServerAddDelInterface 1 }
R2DhcpServerAddDelInterfaceEntry ::= SEQUENCE {
r2DhcpServerAddDelIntfName DisplayString,
r2DhcpServerAddDelIntfCMD INTEGER
}
r2DhcpServerAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1/lan2/bridge group name)"
::= { r2DhcpServerAddDelInterfaceEntry 2 }
r2DhcpServerAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete interface command"
::= { r2DhcpServerAddDelInterfaceEntry 3 }
--
-- R2 DHCP Server Host Table
--
r2DHCPHost OBJECT IDENTIFIER ::= { r2DHCPServer 3 }
--
-- R2 DHCP Server Host Config Table
--
r2DhcpHostCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpHostCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host config Table"
::= { r2DHCPHost 1 }
r2DhcpHostCFGEntry OBJECT-TYPE
SYNTAX R2DhcpHostCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host config Entry"
INDEX { r2Index ,
r2DhcpHostIndex }
::= { r2DhcpHostCFG 1 }
R2DhcpHostCFGEntry ::= SEQUENCE {
r2DhcpHostIndex INTEGER,
r2DhcpHostName DisplayString,
r2DhcpHostHWType INTEGER,
r2DhcpHostHWAddr DisplayString,
r2DhcpHostFixedAddr DisplayString,
r2DhcpHostBootStrapFile DisplayString,
r2DhcpHostNextServer DisplayString,
r2DhcpHostClientIdentifier DisplayString,
r2DhcpHostDefLeaseTime INTEGER
}
r2DhcpHostIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host configuration index"
::= { r2DhcpHostCFGEntry 2 }
r2DhcpHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host configuration name"
::= { r2DhcpHostCFGEntry 3 }
r2DhcpHostHWType OBJECT-TYPE
SYNTAX INTEGER{
null(0),
ethernet(1),
token-ring(2),
fddi(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host hardware type"
::= { r2DhcpHostCFGEntry 4 }
r2DhcpHostHWAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host hardware address"
::= { r2DhcpHostCFGEntry 5 }
r2DhcpHostFixedAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host address"
::= { r2DhcpHostCFGEntry 6 }
r2DhcpHostBootStrapFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host bootstrap file"
::= { r2DhcpHostCFGEntry 7 }
r2DhcpHostNextServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP next server in boot process"
::= { r2DhcpHostCFGEntry 8 }
r2DhcpHostClientIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..9))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host client identifier"
::= { r2DhcpHostCFGEntry 9 }
r2DhcpHostDefLeaseTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host default duration of the lease"
::= { r2DhcpHostCFGEntry 10 }
--
-- R2 Add or Delete DHCP Server Host
--
r2AddDelDhcpHost OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelDhcpHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host control Table"
::= { r2DHCPHost 2 }
r2AddDelDhcpHostEntry OBJECT-TYPE
SYNTAX R2AddDelDhcpHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host control Entry"
INDEX { r2Index }
::= { r2AddDelDhcpHost 1 }
R2AddDelDhcpHostEntry ::= SEQUENCE {
r2AddDelDhcpHostName DisplayString,
r2DhcpHostCMD INTEGER
}
r2AddDelDhcpHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host configuration name"
::= { r2AddDelDhcpHostEntry 2 }
r2DhcpHostCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP host configuration"
::= { r2AddDelDhcpHostEntry 3 }
--
-- R2 DHCP Host Option
--
r2DhcpHostOption OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option Table"
::= { r2DHCPHost 3 }
r2DhcpHostOptionEntry OBJECT-TYPE
SYNTAX R2DhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option Entry"
INDEX { r2Index ,
r2DhcpHostIndex ,
r2DhcpHostOptionIndex }
::= { r2DhcpHostOption 1 }
R2DhcpHostOptionEntry ::= SEQUENCE {
r2DhcpHostOptionIndex INTEGER,
r2DhcpHostOptionHostName DisplayString,
r2DhcpHostOptionCode INTEGER,
r2DhcpHostOptionValue DisplayString
}
r2DhcpHostOptionIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host Option index"
::= { r2DhcpHostOptionEntry 3 }
r2DhcpHostOptionHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host name"
::= { r2DhcpHostOptionEntry 4 }
r2DhcpHostOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host option code"
::= { r2DhcpHostOptionEntry 5 }
r2DhcpHostOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host option value"
::= { r2DhcpHostOptionEntry 6 }
--
-- R2 Add or Delete DHCP Host Option
--
r2AddDelDhcpHostOption OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelDhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option control Table"
::= { r2DHCPHost 4 }
r2AddDelDhcpHostOptionEntry OBJECT-TYPE
SYNTAX R2AddDelDhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option control Entry"
INDEX { r2Index }
::= { r2AddDelDhcpHostOption 1 }
R2AddDelDhcpHostOptionEntry ::= SEQUENCE {
r2AddDelHostOptionHostName DisplayString,
r2AddDelHostOptionCode INTEGER,
r2AddDelHostOptionValue DisplayString,
r2AddDelHostOptionCMD INTEGER
}
r2AddDelHostOptionHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host name"
::= { r2AddDelDhcpHostOptionEntry 2 }
r2AddDelHostOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host option code"
::= { r2AddDelDhcpHostOptionEntry 3 }
r2AddDelHostOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host option value"
::= { r2AddDelDhcpHostOptionEntry 4 }
r2AddDelHostOptionCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete DHCP host option command"
::= { r2AddDelDhcpHostOptionEntry 5 }
--
-- R2 DHCP Server Subnet Table
--
r2DHCPSubnet OBJECT IDENTIFIER ::= { r2DHCPServer 4 }
--
-- R2 DHCP Server Subnet Config-1 Table
--
r2DhcpSubnetCFG1 OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpSubnetCFG1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Table"
::= { r2DHCPSubnet 1 }
r2DhcpSubnetCFG1Entry OBJECT-TYPE
SYNTAX R2DhcpSubnetCFG1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Entry"
INDEX { r2Index ,
r2DhcpSubnetIndex }
::= { r2DhcpSubnetCFG1 1 }
R2DhcpSubnetCFG1Entry ::= SEQUENCE {
r2DhcpSubnetIndex INTEGER,
r2DhcpCfg1SubnetName DisplayString,
r2DhcpSubnetNetworkAddr DisplayString,
r2DhcpSubnetStartAddr DisplayString,
r2DhcpSubnetEndAddr DisplayString,
r2DhcpSubnetBootp INTEGER,
r2DhcpSubnetDefLeaseTime INTEGER,
r2DhcpSubnetBootStrapFile DisplayString,
r2DhcpSubnetNextServer DisplayString
}
r2DhcpSubnetIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet index"
::= { r2DhcpSubnetCFG1Entry 2 }
r2DhcpCfg1SubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2DhcpSubnetCFG1Entry 3 }
r2DhcpSubnetNetworkAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet address/netmask(xxx.xxx.xxx.xxx/xx)"
::= { r2DhcpSubnetCFG1Entry 4 }
r2DhcpSubnetStartAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet ip range(start)"
::= { r2DhcpSubnetCFG1Entry 5 }
r2DhcpSubnetEndAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet ip range(end)"
::= { r2DhcpSubnetCFG1Entry 6 }
r2DhcpSubnetBootp OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet bootp support"
::= { r2DhcpSubnetCFG1Entry 7 }
r2DhcpSubnetDefLeaseTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet default duration of the lease"
::= { r2DhcpSubnetCFG1Entry 8 }
r2DhcpSubnetBootStrapFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet bootstrap file"
::= { r2DhcpSubnetCFG1Entry 9 }
r2DhcpSubnetNextServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet next server in boot process"
::= { r2DhcpSubnetCFG1Entry 10 }
--
-- R2 DHCP Server Subnet Config-2 Table
--
r2DhcpSubnetCFG2 OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpSubnetCFG2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Table"
::= { r2DHCPSubnet 2 }
r2DhcpSubnetCFG2Entry OBJECT-TYPE
SYNTAX R2DhcpSubnetCFG2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Entry"
INDEX { r2Index ,
r2DhcpSubnetIndex }
::= { r2DhcpSubnetCFG2 1 }
R2DhcpSubnetCFG2Entry ::= SEQUENCE {
r2DhcpCfg2SubnetName DisplayString,
r2DhcpSubnetDomainName DisplayString,
r2DhcpSubnetDNSServer1 DisplayString,
r2DhcpSubnetDNSServer2 DisplayString,
r2DhcpSubnetDNSServer3 DisplayString,
r2DhcpSubnetDNSServer4 DisplayString,
r2DhcpSubnetDefRouter1 DisplayString,
r2DhcpSubnetDefRouter2 DisplayString,
r2DhcpSubnetDefRouter3 DisplayString,
r2DhcpSubnetDefRouter4 DisplayString,
r2DhcpSubnetNetbiosServer1 DisplayString,
r2DhcpSubnetNetbiosServer2 DisplayString,
r2DhcpSubnetNetbiosServer3 DisplayString,
r2DhcpSubnetNetbiosServer4 DisplayString,
r2DhcpSubnetNetbiosNode INTEGER
}
r2DhcpCfg2SubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2DhcpSubnetCFG2Entry 3 }
r2DhcpSubnetDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name"
::= { r2DhcpSubnetCFG2Entry 4 }
r2DhcpSubnetDNSServer1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 1"
::= { r2DhcpSubnetCFG2Entry 5 }
r2DhcpSubnetDNSServer2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 2"
::= { r2DhcpSubnetCFG2Entry 6 }
r2DhcpSubnetDNSServer3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 3"
::= { r2DhcpSubnetCFG2Entry 7 }
r2DhcpSubnetDNSServer4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 4"
::= { r2DhcpSubnetCFG2Entry 8 }
r2DhcpSubnetDefRouter1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 1"
::= { r2DhcpSubnetCFG2Entry 9 }
r2DhcpSubnetDefRouter2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 2"
::= { r2DhcpSubnetCFG2Entry 10 }
r2DhcpSubnetDefRouter3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 3"
::= { r2DhcpSubnetCFG2Entry 11 }
r2DhcpSubnetDefRouter4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 4"
::= { r2DhcpSubnetCFG2Entry 12 }
r2DhcpSubnetNetbiosServer1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 1"
::= { r2DhcpSubnetCFG2Entry 13 }
r2DhcpSubnetNetbiosServer2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 2"
::= { r2DhcpSubnetCFG2Entry 14 }
r2DhcpSubnetNetbiosServer3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 3"
::= { r2DhcpSubnetCFG2Entry 15 }
r2DhcpSubnetNetbiosServer4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 4"
::= { r2DhcpSubnetCFG2Entry 16 }
r2DhcpSubnetNetbiosNode OBJECT-TYPE
SYNTAX INTEGER{
null(0),
b-node(1),
p-node(2),
m-node(4),
h-node(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios node type"
::= { r2DhcpSubnetCFG2Entry 17 }
--
-- R2 Add or Delete DHCP Subnet
--
r2AddDelDhcpSubnet OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelDhcpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet control Table"
::= { r2DHCPSubnet 3 }
r2AddDelDhcpSubnetEntry OBJECT-TYPE
SYNTAX R2AddDelDhcpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet control Entry"
INDEX { r2Index }
::= { r2AddDelDhcpSubnet 1 }
R2AddDelDhcpSubnetEntry ::= SEQUENCE {
r2AddDelDhcpSubnetName DisplayString,
r2DhcpSubnetCMD INTEGER
}
r2AddDelDhcpSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name"
::= { r2AddDelDhcpSubnetEntry 2 }
r2DhcpSubnetCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet configuration"
::= { r2AddDelDhcpSubnetEntry 3 }
--
-- R2 Add or Delete DHCP Subnet DNS Server
--
r2AddDelSubnetDNSServer OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelSubnetDNSServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server control Table"
::= { r2DHCPSubnet 4 }
r2AddDelSubnetDNSServerEntry OBJECT-TYPE
SYNTAX R2AddDelSubnetDNSServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server control Entry"
INDEX { r2Index }
::= { r2AddDelSubnetDNSServer 1 }
R2AddDelSubnetDNSServerEntry ::= SEQUENCE {
r2AddDelDNSServerSubnetName DisplayString,
r2AddDelDNSServerAddr DisplayString,
r2AddDelDNSSeverCMD INTEGER
}
r2AddDelDNSServerSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2AddDelSubnetDNSServerEntry 2 }
r2AddDelDNSServerAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server Address"
::= { r2AddDelSubnetDNSServerEntry 3 }
r2AddDelDNSSeverCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet DNS Server"
::= { r2AddDelSubnetDNSServerEntry 4 }
--
-- R2 Add or Delete DHCP Subnet Default Routers
--
r2AddDelSubnetDefRouter OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelSubnetDefRouterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet default router control Table"
::= { r2DHCPSubnet 5 }
r2AddDelSubnetDefRouterEntry OBJECT-TYPE
SYNTAX R2AddDelSubnetDefRouterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet default router control Entry"
INDEX { r2Index }
::= { r2AddDelSubnetDefRouter 1 }
R2AddDelSubnetDefRouterEntry ::= SEQUENCE {
r2AddDelDefRTRSubnetName DisplayString,
r2AddDelDefRouterAddr DisplayString,
r2AddDelDefRouterCMD INTEGER
}
r2AddDelDefRTRSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2AddDelSubnetDefRouterEntry 2 }
r2AddDelDefRouterAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet default router address"
::= { r2AddDelSubnetDefRouterEntry 3 }
r2AddDelDefRouterCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet default router"
::= { r2AddDelSubnetDefRouterEntry 4 }
--
-- R2 Add or Delete DHCP Subnet Netbios Server
--
r2AddDelSubnetNetbiosServer OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelSubnetNetbiosServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server control Table"
::= { r2DHCPSubnet 6 }
r2AddDelSubnetNetbiosServerEntry OBJECT-TYPE
SYNTAX R2AddDelSubnetNetbiosServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server control Entry"
INDEX { r2Index }
::= { r2AddDelSubnetNetbiosServer 1 }
R2AddDelSubnetNetbiosServerEntry ::= SEQUENCE {
r2AddDelNetbSubnetName DisplayString,
r2AddDelNetbServerAddr DisplayString,
r2AddDelNetbServerCMD INTEGER
}
r2AddDelNetbSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2AddDelSubnetNetbiosServerEntry 2 }
r2AddDelNetbServerAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server address"
::= { r2AddDelSubnetNetbiosServerEntry 3 }
r2AddDelNetbServerCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet netbios server"
::= { r2AddDelSubnetNetbiosServerEntry 4 }
--
-- R2 DHCP Subnet Option
--
r2DhcpSubnetOption OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option Table"
::= { r2DHCPSubnet 7 }
r2DhcpSubnetOptionEntry OBJECT-TYPE
SYNTAX R2DhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option Entry"
INDEX { r2Index ,
r2DhcpSubnetIndex ,
r2DhcpSubnetOptionIndex }
::= { r2DhcpSubnetOption 1 }
R2DhcpSubnetOptionEntry ::= SEQUENCE {
r2DhcpSubnetOptionIndex INTEGER,
r2DhcpSubnetOptSubnetName DisplayString,
r2DhcpSubnetOptionCode INTEGER,
r2DhcpSubnetOptionValue DisplayString
}
r2DhcpSubnetOptionIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet Option index"
::= { r2DhcpSubnetOptionEntry 3 }
r2DhcpSubnetOptSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2DhcpSubnetOptionEntry 4 }
r2DhcpSubnetOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet option code"
::= { r2DhcpSubnetOptionEntry 5 }
r2DhcpSubnetOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet option value"
::= { r2DhcpSubnetOptionEntry 6 }
--
-- R2 Add or Delete DHCP Subnet Option
--
r2AddDelDhcpSubnetOption OBJECT-TYPE
SYNTAX SEQUENCE OF R2AddDelDhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option control Table"
::= { r2DHCPSubnet 8 }
r2AddDelDhcpSubnetOptionEntry OBJECT-TYPE
SYNTAX R2AddDelDhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option control Entry"
INDEX { r2Index }
::= { r2AddDelDhcpSubnetOption 1 }
R2AddDelDhcpSubnetOptionEntry ::= SEQUENCE {
r2AddDelSubnetOptSubnetName DisplayString,
r2AddDelSubnetOptionCode INTEGER,
r2AddDelSubnetOptionValue DisplayString,
r2AddDelSubnetOptionCMD INTEGER
}
r2AddDelSubnetOptSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r2AddDelDhcpSubnetOptionEntry 2 }
r2AddDelSubnetOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet option code"
::= { r2AddDelDhcpSubnetOptionEntry 3 }
r2AddDelSubnetOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet option value"
::= { r2AddDelDhcpSubnetOptionEntry 4 }
r2AddDelSubnetOptionCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete DHCP subnet option"
::= { r2AddDelDhcpSubnetOptionEntry 5 }
--
-- R2 DHCP Relay
--
r2DHCPRelay OBJECT IDENTIFIER ::= { r2DHCP 2 }
--
-- R2 DHCP Relay Config
--
r2DhcpRelayCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpRelayCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Relay Config Table"
::= { r2DHCPRelay 1 }
r2DhcpRelayCFGEntry OBJECT-TYPE
SYNTAX R2DhcpRelayCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Relay Config Entry"
INDEX { r2Index }
::= { r2DhcpRelayCFG 1 }
R2DhcpRelayCFGEntry ::= SEQUENCE {
r2DhcpRelay INTEGER,
r2DhcpRelayServerIP DisplayString,
r2DhcpRelayInterface DisplayString,
r2DhcpRelayBridgeMgmt DisplayString
}
r2DhcpRelay OBJECT-TYPE
SYNTAX INTEGER{
na(0),
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP relay function disable/enable"
::= { r2DhcpRelayCFGEntry 2 }
r2DhcpRelayServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP Relay Server IP"
::= { r2DhcpRelayCFGEntry 3 }
r2DhcpRelayInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP relay interface"
::= { r2DhcpRelayCFGEntry 4 }
r2DhcpRelayBridgeMgmt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP relay bridge mgmt"
::= { r2DhcpRelayCFGEntry 5 }
--
-- R2 Add or Delete DHCP Relay Interface
--
r2DhcpRelayAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R2DhcpRelayAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP Relay interface Table"
::= { r2DHCPRelay 2 }
r2DhcpRelayAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R2DhcpRelayAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP Relay interface Entry"
INDEX { r2Index }
::= { r2DhcpRelayAddDelInterface 1 }
R2DhcpRelayAddDelInterfaceEntry ::= SEQUENCE {
r2DhcpRelayAddDelIntfName DisplayString,
r2DhcpRelayAddDelIntfCMD INTEGER
}
r2DhcpRelayAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r2DhcpRelayAddDelInterfaceEntry 2 }
r2DhcpRelayAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete interface command"
::= { r2DhcpRelayAddDelInterfaceEntry 3 }
--
-- R2 MultiLink
--
r2MultiLink OBJECT IDENTIFIER ::= { router-a-card 10 }
--
-- R2 MultiLink Config Table
--
r2MultiLinkCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R2MultiLinkCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MultiLink Config Table."
::= { r2MultiLink 1 }
r2MultiLinkCFGEntry OBJECT-TYPE
SYNTAX R2MultiLinkCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MultiLink Config Entry"
INDEX { r2Index ,
r2MLinkIndex }
::= { r2MultiLinkCFG 1 }
R2MultiLinkCFGEntry ::= SEQUENCE {
r2MLinkIndex INTEGER,
r2MLinkName DisplayString,
r2MLinkIPAddr DisplayString,
r2MLinkBundles DisplayString,
r2MLinkInterval INTEGER,
r2MLinkTimes INTEGER
}
r2MLinkIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Index"
::= { r2MultiLinkCFGEntry 2 }
r2MLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Virtual Name"
::= { r2MultiLinkCFGEntry 3 }
r2MLinkIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r2MultiLinkCFGEntry 4 }
r2MLinkBundles OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Boundles Interface"
::= { r2MultiLinkCFGEntry 5 }
r2MLinkInterval OBJECT-TYPE
SYNTAX INTEGER (5..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink The Retry Interval"
::= { r2MultiLinkCFGEntry 6 }
r2MLinkTimes OBJECT-TYPE
SYNTAX INTEGER (6..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink The Retry Times"
::= { r2MultiLinkCFGEntry 7 }
--
-- R2 Create and Destroy Multilink
--
r2CreateDestroyMultiLink OBJECT-TYPE
SYNTAX SEQUENCE OF R2CreateDestroyMultiLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy MultiLink Table."
::= { r2MultiLink 2 }
r2CreateDestroyMultiLinkEntry OBJECT-TYPE
SYNTAX R2CreateDestroyMultiLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Multilin Entry"
INDEX { r2Index }
::= { r2CreateDestroyMultiLink 1 }
R2CreateDestroyMultiLinkEntry ::= SEQUENCE {
r2CreateDestroyMLinkName DisplayString,
r2CreateDestroyMLinkCMD INTEGER
}
r2CreateDestroyMLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Destroy Multilink Name"
::= { r2CreateDestroyMultiLinkEntry 2 }
r2CreateDestroyMLinkCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0),
create(1),
destroy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Destory Multilink Command"
::= { r2CreateDestroyMultiLinkEntry 3 }
--
-- R2 MultiLink Add/Delete Interface Table
--
r2MultiLinkAddDeleteInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R2MultiLinkAddDeleteInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add/Delete Interfaces To Multilink Bundle Table"
::= { r2MultiLink 3 }
r2MultiLinkAddDeleteInterfaceEntry OBJECT-TYPE
SYNTAX R2MultiLinkAddDeleteInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add/Delete Interfaces To Multilink Bundle Entry"
INDEX { r2Index }
::= { r2MultiLinkAddDeleteInterface 1 }
R2MultiLinkAddDeleteInterfaceEntry ::= SEQUENCE {
r2MLinkAddDelMLinkName DisplayString,
r2MLinkAddDelIntfName DisplayString,
r2MLinkAddDelIntfCMD INTEGER
}
r2MLinkAddDelMLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"R2 Add/Delete Interface MultiLink Name"
::= { r2MultiLinkAddDeleteInterfaceEntry 2 }
r2MLinkAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"R2 Add/Delete Interfaces(wan1~wan64) to Multilink Bundle"
::= { r2MultiLinkAddDeleteInterfaceEntry 3 }
r2MLinkAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete interfaces To/From Multilink Bundle"
::= { r2MultiLinkAddDeleteInterfaceEntry 4 }
--==================================================
-- SVLAN
--==================================================
r2svlan OBJECT IDENTIFIER ::= { router-a-card 11 }
--==================================================
-- SVLAN State
--==================================================
r2svlanState OBJECT-TYPE
SYNTAX SEQUENCE OF R2SvlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Table"
::= { r2svlan 1 }
r2svlanStateEntry OBJECT-TYPE
SYNTAX R2SvlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Svlan state Entry"
INDEX { r2ssIndex , r2svlanBrgGroupID }
::= { r2svlanState 1 }
R2SvlanStateEntry ::= SEQUENCE {
r2ssIndex SmallSlotIndex,
r2svlanBrgGroupID INTEGER,
r2svlanBrgName DisplayString,
r2svlanEnable INTEGER,
r2svlanMgmtSVID INTEGER,
r2svlanRegenCRC INTEGER,
r2svlanTPID DisplayString,
r2svlanPCP INTEGER,
r2svlanDEI INTEGER
}
r2ssIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2svlanStateEntry 1 }
r2svlanBrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group ID"
::= { r2svlanStateEntry 2 }
r2svlanBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2svlanStateEntry 3 }
r2svlanEnable OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan state enable/disable"
::= { r2svlanStateEntry 4 }
r2svlanMgmtSVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVLAN ID for the bridge management interface"
::= { r2svlanStateEntry 5 }
r2svlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable CRC regenerating on WAN interfaces for SVLAN frames"
::= { r2svlanStateEntry 6 }
r2svlanTPID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TPID "
::= { r2svlanStateEntry 7 }
r2svlanPCP OBJECT-TYPE
SYNTAX INTEGER(0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Priority Code Point"
::= { r2svlanStateEntry 8 }
r2svlanDEI OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Drop Eligible Indicato"
::= { r2svlanStateEntry 9 }
--==================================================
-- SVLAN Table
--==================================================
r2svlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2SvlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan Table"
::= { r2svlan 2 }
r2svlanTableEntry OBJECT-TYPE
SYNTAX R2SvlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Svlan Table Tag Member Entry"
INDEX { r2stIndex ,
r2svlanTableBrgGroupID ,
r2svlanID ,
r2svlanTableIndex
}
::= { r2svlanTable 1 }
R2SvlanTableEntry ::= SEQUENCE {
r2stIndex SmallSlotIndex,
r2svlanTableBrgGroupID INTEGER,
r2svlanID INTEGER,
r2svlanTableIndex INTEGER,
r2svlanMember DisplayString
}
r2stIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2svlanTableEntry 1 }
r2svlanTableBrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group Index"
::= { r2svlanTableEntry 2 }
r2svlanID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { r2svlanTableEntry 3 }
r2svlanTableIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Member Index"
::= { r2svlanTableEntry 4 }
r2svlanMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member"
::= { r2svlanTableEntry 5 }
--=========================================================
-- SVLAN Table Control
--=========================================================
r2svlanTableControl OBJECT IDENTIFIER ::= { r2svlan 3 }
--=========================================================
-- SVLAN Create and Destroy
--=========================================================
r2svlanCreateDestroyVlan OBJECT-TYPE
SYNTAX SEQUENCE OF R2SvlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy svlan Table"
::= { r2svlanTableControl 1 }
r2svlanCreateDestroyVlanEntry OBJECT-TYPE
SYNTAX R2SvlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy svlan Entry"
INDEX { r2scIndex }
::= { r2svlanCreateDestroyVlan 1 }
R2SvlanCreateDestroyVlanEntry ::= SEQUENCE {
r2scIndex SmallSlotIndex,
r2svlanCreateDestroyBrgName DisplayString,
r2svlanCreateDestroyVidNum INTEGER,
r2svlanCreateDestroyCMD INTEGER
}
r2scIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2svlanCreateDestroyVlanEntry 1 }
r2svlanCreateDestroyBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2svlanCreateDestroyVlanEntry 2 }
r2svlanCreateDestroyVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan VID"
::= { r2svlanCreateDestroyVlanEntry 3 }
r2svlanCreateDestroyCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
create-svlan(1),
destroy-svlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create and destroy Svlan command"
::= { r2svlanCreateDestroyVlanEntry 4 }
--=========================================================
-- SVLAN Add and Delete Port
--=========================================================
r2svlanAddDelPort OBJECT-TYPE
SYNTAX SEQUENCE OF R2SvlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan add and del port Table"
::= { r2svlanTableControl 2 }
r2svlanAddDelPortEntry OBJECT-TYPE
SYNTAX R2SvlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan add and del port Entry"
INDEX { r2saIndex }
::= { r2svlanAddDelPort 1 }
R2SvlanAddDelPortEntry ::= SEQUENCE {
r2saIndex SmallSlotIndex,
r2svlanAddDelPortBrgName DisplayString,
r2svlanAddDelPortVidNum INTEGER,
r2svlanAddDelPortInterface DisplayString,
r2svlanAddDelPortCMD INTEGER
}
r2saIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2svlanAddDelPortEntry 1 }
r2svlanAddDelPortBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r2svlanAddDelPortEntry 2 }
r2svlanAddDelPortVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan VID"
::= { r2svlanAddDelPortEntry 3 }
r2svlanAddDelPortInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r2svlanAddDelPortEntry 4 }
r2svlanAddDelPortCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add-port-to-svlan(1),
delete-port-from-svlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan add and delete port command"
::= { r2svlanAddDelPortEntry 5 }
--=========================================================
-- SVLAN Port Table
--=========================================================
r2svlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF R2SvlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Table"
::= { r2svlan 4 }
r2svlanPortTableEntry OBJECT-TYPE
SYNTAX R2SvlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Entry"
INDEX { r2spIndex , r2svlanPortIndex }
::= { r2svlanPortTable 1 }
R2SvlanPortTableEntry ::= SEQUENCE {
r2spIndex SmallSlotIndex,
r2svlanPortIndex INTEGER,
r2svlanPortIFName DisplayString,
r2svlanPortPVID INTEGER,
r2svlanPortType INTEGER,
r2svlanPortIngressFilter INTEGER
}
r2spIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { r2svlanPortTableEntry 1 }
r2svlanPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan port index"
::= { r2svlanPortTableEntry 2 }
r2svlanPortIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface name"
::= { r2svlanPortTableEntry 3 }
r2svlanPortPVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface PVID"
::= { r2svlanPortTableEntry 4 }
r2svlanPortType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
provider(1),
customer(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"the acceptable port type"
::= { r2svlanPortTableEntry 5 }
r2svlanPortIngressFilter OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable ingress filtering"
::= { r2svlanPortTableEntry 6 }
r2TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of RTA"
::= { router-a-card 100 }
--======================================================================--
--======================================================================--
-- LS-OPTICAL MIB
--======================================================================--
--======================================================================--
--
-- SYSTEM Control Table
--
lsoSystemControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LS-OPTICAL control table."
::= { ls-optical-card 1 }
lsoSystemControlEntry OBJECT-TYPE
SYNTAX LsoSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the LS-OPTICAL control table."
INDEX { lsoIndex ,
lsoPortIndex }
::= { lsoSystemControlTable 1 }
LsoSystemControlEntry ::= SEQUENCE {
lsoIndex GenSlotID,
lsoPortIndex FourPortID,
lsoMode INTEGER,
lsoReceiveBW INTEGER,
lsoTransmitBW INTEGER,
lsoALS INTEGER
}
lsoIndex OBJECT-TYPE
SYNTAX GenSlotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { lsoSystemControlEntry 1 }
lsoPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { lsoSystemControlEntry 2 }
lsoMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
auto(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LS-OPTICAL Mode"
::= { lsoSystemControlEntry 3 }
lsoReceiveBW OBJECT-TYPE
SYNTAX INTEGER (0..12)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"LS-OPTICAL reveive bandwidth(0~12 TS)"
::= { lsoSystemControlEntry 4 }
lsoTransmitBW OBJECT-TYPE
SYNTAX INTEGER (0..12)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LS-OPTICAL transmit bandwidth(0~12 TS)"
::= { lsoSystemControlEntry 5 }
lsoALS OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LS-OPTICAL Auto Laser Shutdown(ALS)"
::= { lsoSystemControlEntry 6 }
--
-- Status Table
--
lsoStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The LS-OPTICAL status table."
::= { ls-optical-card 2 }
lsoStatusEntry OBJECT-TYPE
SYNTAX LsoStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the LS-OPTICAL status table."
INDEX { lsoIndex ,
lsoPortIndex }
::= { lsoStatusTable 1 }
LsoStatusEntry ::= SEQUENCE {
lsoLOS INTEGER,
lsoYEL INTEGER,
lsoFramingERR INTEGER,
lsoPayloadERR INTEGER
}
lsoLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LS-OPTICAL Line LOS "
::= { lsoStatusEntry 1 }
lsoYEL OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yel(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LS-OPTICAL Line YEL "
::= { lsoStatusEntry 2 }
lsoFramingERR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LS-OPTICAL Framing Error Counter "
::= { lsoStatusEntry 3 }
lsoPayloadERR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LS-OPTICAL Payload Error Counter "
::= { lsoStatusEntry 4 }
--
-- Diagnostic Control Table
--
lsoDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagnostic Control Table"
::= { ls-optical-card 3 }
lsoDiagEntry OBJECT-TYPE
SYNTAX LsoDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagnostic Control Table Entry"
INDEX { lsoIndex ,
lsoPortIndex }
::= { lsoDiagTable 1 }
LsoDiagEntry ::= SEQUENCE {
lsoLoopback INTEGER,
lsoBertControl INTEGER,
lsoBertStatus INTEGER,
lsoElapseSeconds INTEGER,
lsoErrorSeconds INTEGER,
lsoErrorBits INTEGER
}
lsoLoopback OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payLoad-loopback(3),
line-loopback(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Loopback Type"
::= { lsoDiagEntry 1 }
lsoBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
bert-on(2),
reset(3),
inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Control"
::= { lsoDiagEntry 2 }
lsoBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { lsoDiagEntry 3 }
lsoElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapse seconds"
::= { lsoDiagEntry 4 }
lsoErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error seconds"
::= { lsoDiagEntry 5 }
lsoErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error bits"
::= { lsoDiagEntry 6 }
--
-- Alarm Status Table
--
lsoAlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Status Table"
::= { ls-optical-card 4 }
lsoAlmStatusEntry OBJECT-TYPE
SYNTAX LsoAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Status Table Entry"
INDEX { lsoIndex ,
lsoPortIndex ,
lsoAlmNumber }
::= { lsoAlmStatusTable 1 }
LsoAlmStatusEntry ::= SEQUENCE {
lsoAlmNumber INTEGER,
lsoAlmString DisplayString,
lsoAlmState INTEGER,
lsoAlmCount INTEGER,
lsoAlmThreshold INTEGER,
lsoAlmEnable AlarmSeverity
}
lsoAlmNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Status Index"
::= { lsoAlmStatusEntry 1 }
lsoAlmString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { lsoAlmStatusEntry 2 }
lsoAlmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Current State"
::= { lsoAlmStatusEntry 3 }
lsoAlmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Count which happened"
::= { lsoAlmStatusEntry 4 }
lsoAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Threshold"
::= { lsoAlmStatusEntry 5 }
lsoAlmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { lsoAlmStatusEntry 6 }
--
-- Command Control Table
--
lsoCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { ls-optical-card 5 }
lsoCommandControlEntry OBJECT-TYPE
SYNTAX LsoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { lsoIndex }
::= { lsoCommandControlTable 1 }
LsoCommandControlEntry ::= SEQUENCE {
lsoClearCardAlarmHistory INTEGER,
lsoClearCardPerformanceData INTEGER,
lsoCardLoadDefault INTEGER
}
lsoClearCardAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear Card Alarm History"
::= { lsoCommandControlEntry 1 }
lsoClearCardPerformanceData OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear card performance data"
::= { lsoCommandControlEntry 2 }
lsoCardLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Card Load Default"
::= { lsoCommandControlEntry 3 }
--
-- SYSTEM Information Table
--
lsoSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= {ls-optical-card 6 }
lsoSystemInformationEntry OBJECT-TYPE
SYNTAX LsoSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { lsoIndex }
::= { lsoSystemInformationTable 1 }
LsoSystemInformationEntry ::= SEQUENCE {
lsoFPGAVersion DisplayString,
lsoPCBVersion DisplayString,
lsoBOMVersion DisplayString,
lsoPortNumber INTEGER,
lsoOpticalModule DisplayString
}
lsoFPGAVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { lsoSystemInformationEntry 1 }
lsoPCBVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PCB Version"
::= { lsoSystemInformationEntry 2 }
lsoBOMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BOM Version"
::= { lsoSystemInformationEntry 3 }
lsoPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of port in card"
::= { lsoSystemInformationEntry 4 }
lsoOpticalModule OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..59) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical module type"
::= { lsoSystemInformationEntry 5 }
--
-- Performance Table
--
lsoPerformanceReport OBJECT IDENTIFIER ::= { ls-optical-card 7 }
--
-- Current Performance Table
--
lsoCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Performance Table"
::= { lsoPerformanceReport 1 }
lsoCurrentPerfEntry OBJECT-TYPE
SYNTAX LsoCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current performance entry"
INDEX { lsoIndex ,
lsoPortIndex ,
lsoCurrPerfRegType }
::= { lsoCurrentPerfTable 1 }
LsoCurrentPerfEntry ::= SEQUENCE {
lsoCurrPerfRegType INTEGER,
lsoCurrentPerfES INTEGER,
lsoCurrentPerfSES INTEGER,
lsoCurrentPerfUAS INTEGER,
lsoCurr15MinTimeElapsed INTEGER,
lsoValid15MinInterval INTEGER
}
lsoCurrPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { lsoCurrentPerfEntry 1 }
lsoCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { lsoCurrentPerfEntry 2 }
lsoCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { lsoCurrentPerfEntry 3 }
lsoCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { lsoCurrentPerfEntry 4 }
lsoCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { lsoCurrentPerfEntry 5 }
lsoValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { lsoCurrentPerfEntry 6 }
--
-- Interval Performance Table
--
lsoIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval Performance Table"
::= { lsoPerformanceReport 2 }
lsoIntervalPerfEntry OBJECT-TYPE
SYNTAX LsoIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical interval performance entry"
INDEX { lsoIndex ,
lsoPortIndex ,
lsoIntvPerfRegType ,
lsoIntervalPerfNumber }
::= { lsoIntervalPerfTable 1 }
LsoIntervalPerfEntry ::= SEQUENCE {
lsoIntvPerfRegType INTEGER,
lsoIntervalPerfNumber INTEGER (1..96),
lsoIntervalPerfES INTEGER,
lsoIntervalPerfSES INTEGER,
lsoIntervalPerfUAS INTEGER
}
lsoIntvPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { lsoIntervalPerfEntry 1 }
lsoIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { lsoIntervalPerfEntry 2 }
lsoIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { lsoIntervalPerfEntry 3 }
lsoIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { lsoIntervalPerfEntry 4 }
lsoIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { lsoIntervalPerfEntry 5 }
--
-- Total Performance Table
--
lsoTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Performance Table"
::= { lsoPerformanceReport 3 }
lsoTotalPerfEntry OBJECT-TYPE
SYNTAX LsoTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total performance table"
INDEX { lsoIndex ,
lsoPortIndex ,
lsoTotalPerfRegType }
::= { lsoTotalPerfTable 1 }
LsoTotalPerfEntry ::= SEQUENCE {
lsoTotalPerfRegType INTEGER,
lsoTotalPerfES INTEGER,
lsoTotalPerfSES INTEGER,
lsoTotalPerfUAS INTEGER
}
lsoTotalPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { lsoTotalPerfEntry 1 }
lsoTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { lsoTotalPerfEntry 2 }
lsoTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { lsoTotalPerfEntry 3 }
lsoTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { lsoTotalPerfEntry 4 }
--
-- Seven Days Performance Table
--
lsoSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF LsoSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { lsoPerformanceReport 4 }
lsoSevenDaysPerfEntry OBJECT-TYPE
SYNTAX LsoSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance entry"
INDEX { lsoIndex ,
lsoPortIndex ,
lsoSevenDaysPerfRegType ,
lsoDaysIndex }
::= { lsoSevenDaysPerfTable 1 }
LsoSevenDaysPerfEntry ::= SEQUENCE {
lsoSevenDaysPerfRegType INTEGER,
lsoDaysIndex INTEGER (1..7),
lsoDateStrIndex DisplayString (SIZE (0..255) ),
lsoSevenDaysPerfES INTEGER,
lsoSevenDaysPerfSES INTEGER,
lsoSevenDaysPerfUAS INTEGER
}
lsoSevenDaysPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { lsoSevenDaysPerfEntry 1 }
lsoDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { lsoSevenDaysPerfEntry 2 }
lsoDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { lsoSevenDaysPerfEntry 3 }
lsoSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { lsoSevenDaysPerfEntry 4 }
lsoSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { lsoSevenDaysPerfEntry 5 }
lsoSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { lsoSevenDaysPerfEntry 6 }
lsoTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of LS Optical"
::= { ls-optical-card 100 }
--======================================================================--
--======================================================================--
-- OCUDP MIB
--======================================================================--
--======================================================================--
--
-- SYSTEM Control Table
--
ocuSystemControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCUDP control table."
::= { ocudp-card 1 }
ocuSystemControlEntry OBJECT-TYPE
SYNTAX OcuSystemControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the OCUDP control table."
INDEX { ocuIndex, ocuPortIndex }
::= { ocuSystemControlTable 1 }
OcuSystemControlEntry ::= SEQUENCE {
ocuIndex LargeSlotIndex,
ocuPortIndex EightPortID,
ocuDataRate INTEGER,
ocuTransparent INTEGER,
ocuPortEnable INTEGER
}
ocuIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ocuSystemControlEntry 1 }
ocuPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 8, total 8 ports."
::= { ocuSystemControlEntry 2 }
ocuDataRate OBJECT-TYPE
SYNTAX INTEGER {
r64k(1),
r56k(2),
r19-2k(3),
r9-6k(4),
r4-8k(5),
r2-4k(6),
r38-4k(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP Data Rate"
::= { ocuSystemControlEntry 3 }
ocuTransparent OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP transparent carry data signal"
::= { ocuSystemControlEntry 4 }
ocuPortEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP port enable/disable"
::= { ocuSystemControlEntry 5 }
--
-- User Define Code Table
--
ocuUserDefineCodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuUserDefineCodeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCUDP user define act/deact code table."
::= { ocudp-card 2 }
ocuUserDefineCodeEntry OBJECT-TYPE
SYNTAX OcuUserDefineCodeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the OCUDP user define code table."
INDEX { ocuIndex }
::= { ocuUserDefineCodeTable 1 }
OcuUserDefineCodeEntry ::= SEQUENCE {
ocuActivationCodeLEN INTEGER,
ocuActivationCode DisplayString,
ocuDeActivationCodeLEN INTEGER,
ocuDeActivationCode DisplayString
}
ocuActivationCodeLEN OBJECT-TYPE
SYNTAX INTEGER (3..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP Activation Code Length"
::= { ocuUserDefineCodeEntry 1 }
ocuActivationCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP Activation Code"
::= { ocuUserDefineCodeEntry 2 }
ocuDeActivationCodeLEN OBJECT-TYPE
SYNTAX INTEGER (3..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP DeActivation Code Length"
::= { ocuUserDefineCodeEntry 3 }
ocuDeActivationCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCUDP DeActivation Code"
::= { ocuUserDefineCodeEntry 4 }
--
-- Status Table
--
ocuStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The OCUDP status table."
::= { ocudp-card 3 }
ocuStatusEntry OBJECT-TYPE
SYNTAX OcuStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the OCUDP status table."
INDEX { ocuIndex ,
ocuPortIndex }
::= { ocuStatusTable 1 }
OcuStatusEntry ::= SEQUENCE {
ocuOOS INTEGER,
ocuLOS INTEGER,
ocuBitError INTEGER,
ocuLOF INTEGER
}
ocuOOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OCUDP Out of Service "
::= { ocuStatusEntry 1 }
ocuLOS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OCUDP Los of Signal "
::= { ocuStatusEntry 2 }
ocuBitError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OCUDP Bit Error Counter "
::= { ocuStatusEntry 3 }
ocuLOF OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OCUDP Out of Frame for 64K line rate "
::= { ocuStatusEntry 4 }
--
-- Diagnostic Control Table
--
ocuDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagnostic Control Table"
::= { ocudp-card 4 }
ocuDiagEntry OBJECT-TYPE
SYNTAX OcuDiagEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagnostic Control Table Entry"
INDEX { ocuIndex ,
ocuPortIndex }
::= { ocuDiagTable 1 }
OcuDiagEntry ::= SEQUENCE {
ocuLocalLoopback INTEGER,
ocuRemoteLoopback INTEGER,
ocuBertControl INTEGER,
ocuBertStatus INTEGER,
ocuElapseSeconds INTEGER,
ocuErrorSeconds INTEGER,
ocuErrorBits INTEGER,
ocuRemoteCallLoopback INTEGER,
ocuForceDisableRemCallLB INTEGER
}
ocuLocalLoopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
line-loopback(2),
local-loopback(3),
bi-direct-loopback(4),
payload-loopback(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local Loopback Type"
::= { ocuDiagEntry 1 }
ocuRemoteLoopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
t1-410(2),
v54(3),
user-define(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote Loopback Type"
::= { ocuDiagEntry 2 }
ocuBertControl OBJECT-TYPE
SYNTAX INTEGER {
bert-off(1),
all-zero(2),
all-one(3),
patt-63(4),
patt-511(5),
patt-2047(6),
reset(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT Test Control"
::= { ocuDiagEntry 3 }
ocuBertStatus OBJECT-TYPE
SYNTAX INTEGER {
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BERT Status"
::= { ocuDiagEntry 4 }
ocuElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapse seconds"
::= { ocuDiagEntry 5 }
ocuErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error seconds"
::= { ocuDiagEntry 6 }
ocuErrorBits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error bits"
::= { ocuDiagEntry 7 }
ocuRemoteCallLoopback OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Call Loopback Status"
::= { ocuDiagEntry 8 }
ocuForceDisableRemCallLB OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force Disable Remote Call Loopback"
::= { ocuDiagEntry 9 }
--
-- Alarm Status Table
--
ocuAlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Status Table"
::= { ocudp-card 5 }
ocuAlmStatusEntry OBJECT-TYPE
SYNTAX OcuAlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Status Table Entry"
INDEX { ocuIndex ,
ocuPortIndex ,
ocuAlmNumber }
::= { ocuAlmStatusTable 1 }
OcuAlmStatusEntry ::= SEQUENCE {
ocuAlmNumber INTEGER,
ocuAlmString DisplayString,
ocuAlmState INTEGER,
ocuAlmCount INTEGER,
ocuAlmThreshold INTEGER,
ocuAlmEnable AlarmSeverity
}
ocuAlmNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Status Index"
::= { ocuAlmStatusEntry 1 }
ocuAlmString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { ocuAlmStatusEntry 2 }
ocuAlmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
portDisabled(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Current State"
::= { ocuAlmStatusEntry 3 }
ocuAlmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Count which happened"
::= { ocuAlmStatusEntry 4 }
ocuAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm Threshold"
::= { ocuAlmStatusEntry 5 }
ocuAlmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { ocuAlmStatusEntry 6 }
--
-- Command Control Table
--
ocuCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { ocudp-card 6 }
ocuCommandControlEntry OBJECT-TYPE
SYNTAX OcuCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { ocuIndex }
::= { ocuCommandControlTable 1 }
OcuCommandControlEntry ::= SEQUENCE {
ocuClearCardAlarmHistory INTEGER,
ocuClearCardPerformanceData INTEGER,
ocuCardLoadDefault INTEGER,
ocuCardReset INTEGER,
ocuPortReset INTEGER,
ocuCardMode INTEGER
}
ocuClearCardAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear Card Alarm History"
::= { ocuCommandControlEntry 1 }
ocuClearCardPerformanceData OBJECT-TYPE
SYNTAX INTEGER {
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear card performance data"
::= { ocuCommandControlEntry 2 }
ocuCardLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Card Load Default"
::= { ocuCommandControlEntry 3 }
ocuCardReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Card Reset"
::= { ocuCommandControlEntry 4 }
ocuPortReset OBJECT-TYPE
SYNTAX INTEGER {
reset-port1(1),
reset-port2(2),
reset-port3(3),
reset-port4(4),
reset-port5(5),
reset-port6(6),
reset-port7(7),
reset-port8(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port Reset"
::= { ocuCommandControlEntry 5 }
ocuCardMode OBJECT-TYPE
SYNTAX INTEGER {
modeA(1),
modeB(2),
modeC(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Card mode support after FPGA version:F"
::= { ocuCommandControlEntry 6 }
--
-- SYSTEM Information Table
--
ocuSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= {ocudp-card 7 }
ocuSystemInformationEntry OBJECT-TYPE
SYNTAX OcuSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { ocuIndex }
::= { ocuSystemInformationTable 1 }
OcuSystemInformationEntry ::= SEQUENCE {
ocuFPGAVersion DisplayString,
ocuPCBVersion DisplayString
}
ocuFPGAVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { ocuSystemInformationEntry 1 }
ocuPCBVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"PCB Version"
::= { ocuSystemInformationEntry 2 }
--
-- Performance Table
--
ocuPerformanceReport OBJECT IDENTIFIER ::= { ocudp-card 8 }
--
-- Current Performance Table
--
ocuCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Performance Table"
::= { ocuPerformanceReport 1 }
ocuCurrentPerfEntry OBJECT-TYPE
SYNTAX OcuCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current performance entry"
INDEX { ocuIndex ,
ocuPortIndex ,
ocuCurrPerfRegType }
::= { ocuCurrentPerfTable 1 }
OcuCurrentPerfEntry ::= SEQUENCE {
ocuCurrPerfRegType INTEGER,
ocuCurrentPerfES INTEGER,
ocuCurrentPerfSES INTEGER,
ocuCurrentPerfUAS INTEGER,
ocuCurr15MinTimeElapsed INTEGER,
ocuValid15MinInterval INTEGER
}
ocuCurrPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { ocuCurrentPerfEntry 1 }
ocuCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { ocuCurrentPerfEntry 2 }
ocuCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { ocuCurrentPerfEntry 3 }
ocuCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { ocuCurrentPerfEntry 4 }
ocuCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { ocuCurrentPerfEntry 5 }
ocuValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { ocuCurrentPerfEntry 6 }
--
-- Interval Performance Table
--
ocuIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval Performance Table"
::= { ocuPerformanceReport 2 }
ocuIntervalPerfEntry OBJECT-TYPE
SYNTAX OcuIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"FOM Optical interval performance entry"
INDEX { ocuIndex ,
ocuPortIndex ,
ocuIntvPerfRegType ,
ocuIntervalPerfNumber }
::= { ocuIntervalPerfTable 1 }
OcuIntervalPerfEntry ::= SEQUENCE {
ocuIntvPerfRegType INTEGER,
ocuIntervalPerfNumber INTEGER (1..96),
ocuIntervalPerfES INTEGER,
ocuIntervalPerfSES INTEGER,
ocuIntervalPerfUAS INTEGER
}
ocuIntvPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { ocuIntervalPerfEntry 1 }
ocuIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { ocuIntervalPerfEntry 2 }
ocuIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { ocuIntervalPerfEntry 3 }
ocuIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { ocuIntervalPerfEntry 4 }
ocuIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { ocuIntervalPerfEntry 5 }
--
-- Total Performance Table
--
ocuTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Performance Table"
::= { ocuPerformanceReport 3 }
ocuTotalPerfEntry OBJECT-TYPE
SYNTAX OcuTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total performance table"
INDEX { ocuIndex ,
ocuPortIndex ,
ocuTotalPerfRegType }
::= { ocuTotalPerfTable 1 }
OcuTotalPerfEntry ::= SEQUENCE {
ocuTotalPerfRegType INTEGER,
ocuTotalPerfES INTEGER,
ocuTotalPerfSES INTEGER,
ocuTotalPerfUAS INTEGER
}
ocuTotalPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { ocuTotalPerfEntry 1 }
ocuTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { ocuTotalPerfEntry 2 }
ocuTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { ocuTotalPerfEntry 3 }
ocuTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { ocuTotalPerfEntry 4 }
--
-- Seven Days Performance Table
--
ocuSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OcuSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { ocuPerformanceReport 4 }
ocuSevenDaysPerfEntry OBJECT-TYPE
SYNTAX OcuSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance entry"
INDEX { ocuIndex ,
ocuPortIndex ,
ocuSevenDaysPerfRegType ,
ocuDaysIndex }
::= { ocuSevenDaysPerfTable 1 }
OcuSevenDaysPerfEntry ::= SEQUENCE {
ocuSevenDaysPerfRegType INTEGER,
ocuDaysIndex INTEGER (1..7),
ocuDateStrIndex DisplayString (SIZE (0..255) ),
ocuSevenDaysPerfES INTEGER,
ocuSevenDaysPerfSES INTEGER,
ocuSevenDaysPerfUAS INTEGER
}
ocuSevenDaysPerfRegType OBJECT-TYPE
SYNTAX INTEGER {
user(1),
line(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Performance Register Type "
::= { ocuSevenDaysPerfEntry 1 }
ocuDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { ocuSevenDaysPerfEntry 2 }
ocuDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { ocuSevenDaysPerfEntry 3 }
ocuSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { ocuSevenDaysPerfEntry 4 }
ocuSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { ocuSevenDaysPerfEntry 5 }
ocuSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { ocuSevenDaysPerfEntry 6 }
ocuTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of OCUDP"
::= { ocudp-card 100 }
--======================================================================--
--======================================================================--
-- OCT-RT-B MIB
--======================================================================--
--======================================================================--
--
-- Alarm Status Table
--
r8AlmStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Status Table "
::= { oct-rt-b-card 1 }
r8AlmStatusEntry OBJECT-TYPE
SYNTAX R8AlmStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { r8Index ,
r8AlmStatusNumber }
::= { r8AlmStatusTable 1 }
R8AlmStatusEntry ::= SEQUENCE {
r8Index LargeSlotIndex,
r8AlmStatusNumber INTEGER (1..40),
r8AlmStatusString DisplayString,
r8AlmStatusState INTEGER,
r8AlmStatusCount INTEGER,
r8AlmStatusEnable AlarmSeverity
}
r8Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8AlmStatusEntry 1 }
r8AlmStatusNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Status Index "
::= { r8AlmStatusEntry 2 }
r8AlmStatusString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Type String"
::= { r8AlmStatusEntry 3 }
r8AlmStatusState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
none(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { r8AlmStatusEntry 4 }
r8AlmStatusCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { r8AlmStatusEntry 5 }
r8AlmStatusEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { r8AlmStatusEntry 6 }
--
-- Command Control Table
--
r8CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { oct-rt-b-card 2 }
r8CommandControlEntry OBJECT-TYPE
SYNTAX R8CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { r8Index }
::= { r8CommandControlTable 1 }
R8CommandControlEntry ::= SEQUENCE {
r8ClearAlarmHistory INTEGER,
r8LoadDefaultAlarmCfg INTEGER,
r8Reset INTEGER,
r8ReturnToDefault INTEGER,
r8SaveConfig INTEGER
}
r8ClearAlarmHistory OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Clear Alarm History"
::= { r8CommandControlEntry 2 }
r8LoadDefaultAlarmCfg OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Alarm Config"
::= { r8CommandControlEntry 3 }
r8Reset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Card"
::= { r8CommandControlEntry 4 }
r8ReturnToDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
return-to-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Return to default"
::= { r8CommandControlEntry 5 }
r8SaveConfig OBJECT-TYPE
SYNTAX INTEGER {
no(0),
save-config(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Save config"
::= { r8CommandControlEntry 6 }
--
-- OCT-RT-B Bridge
--
r8Bridge OBJECT IDENTIFIER ::= { oct-rt-b-card 3 }
--
-- OCT-RT-B Create and Destroy Bridge
--
r8CreateDestroyBridge OBJECT-TYPE
SYNTAX SEQUENCE OF R8CreateDestroyBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCT-RT-B Create and Destroy Bridge Table."
::= { r8Bridge 1 }
r8CreateDestroyBridgeEntry OBJECT-TYPE
SYNTAX R8CreateDestroyBridgeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCT-RT-B Create and Destroy Bridge Entry"
INDEX { r8Index }
::= { r8CreateDestroyBridge 1 }
R8CreateDestroyBridgeEntry ::= SEQUENCE {
r8BridgeName DisplayString,
r8BridgeMacAddr DisplayString,
r8BridgeCMD INTEGER
}
r8BridgeName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Name"
::= { r8CreateDestroyBridgeEntry 2 }
r8BridgeMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Management Mac (xx:xx:xx:xx:xx:xx)"
::= { r8CreateDestroyBridgeEntry 3 }
r8BridgeCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
create(1),
destroy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Index"
::= { r8CreateDestroyBridgeEntry 4 }
--
-- OCT-RT-B Bridge Config Table
--
r8BridgeCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8BridgeCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R8 Bridge Config Table."
::= { r8Bridge 2 }
r8BridgeCFGEntry OBJECT-TYPE
SYNTAX R8BridgeCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"R8 Bridge Config Entry"
INDEX { r8Index ,
r8BrgGroupID }
::= { r8BridgeCFG 1 }
R8BridgeCFGEntry ::= SEQUENCE {
r8BrgGroupID INTEGER,
r8BrgName DisplayString,
r8BrgManagementAddr DisplayString,
r8BrgManagementMac DisplayString,
r8BrgMacAgingTime INTEGER,
r8BrgCRC INTEGER,
r8BrgManageState INTEGER,
r8BrgInboundPolicy DisplayString,
r8BrgOutboundPolicy DisplayString,
r8BrgSTPState INTEGER,
r8BrgSTPProtocolVersion INTEGER,
r8BrgSTPHelloTime INTEGER,
r8BrgSTPMacAgingTime INTEGER,
r8BrgSTPForwardDelay INTEGER,
r8BrgSTPPriority INTEGER,
r8BrgL2PDUtunneling INTEGER,
r8BrgRoutingProtocol INTEGER
}
r8BrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group ID"
::= { r8BridgeCFGEntry 2 }
r8BrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group Name"
::= { r8BridgeCFGEntry 3 }
r8BrgManagementAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Management IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r8BridgeCFGEntry 4 }
r8BrgManagementMac OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Management Mac (xx:xx:xx:xx:xx:xx)"
::= { r8BridgeCFGEntry 5 }
r8BrgMacAgingTime OBJECT-TYPE
SYNTAX INTEGER (10..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge MAC Aging Time(10-1000000 Sec)"
::= { r8BridgeCFGEntry 6 }
r8BrgCRC OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Disable/Enable CRC"
::= { r8BridgeCFGEntry 7 }
r8BrgManageState OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicated whether the mgmt attached with epilogue"
::= { r8BridgeCFGEntry 8 }
r8BrgInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Inbound policy"
::= { r8BridgeCFGEntry 9 }
r8BrgOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Inbound policy"
::= { r8BridgeCFGEntry 10 }
r8BrgSTPState OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree disable/enable"
::= { r8BridgeCFGEntry 11 }
r8BrgSTPProtocolVersion OBJECT-TYPE
SYNTAX INTEGER {
stp(1),
rstp(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Protocol Version"
::= { r8BridgeCFGEntry 12 }
r8BrgSTPHelloTime OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Hello Time(1-10 Sec)"
::= { r8BridgeCFGEntry 13 }
r8BrgSTPMacAgingTime OBJECT-TYPE
SYNTAX INTEGER (6..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Aging Time(6-40 Sec)"
::= { r8BridgeCFGEntry 14 }
r8BrgSTPForwardDelay OBJECT-TYPE
SYNTAX INTEGER (4..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Forward Delay Time(4-30 Sec)"
::= { r8BridgeCFGEntry 15 }
r8BrgSTPPriority OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Priority (0-65535)"
::= { r8BridgeCFGEntry 16 }
r8BrgL2PDUtunneling OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Disable/Enable BPDU"
::= { r8BridgeCFGEntry 17 }
r8BrgRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
ripV1(1),
ripV2(2),
disable(4),
notSupport(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Bridge routing protocol"
::= { r8BridgeCFGEntry 18 }
--
-- OCT-RT-B Bridge STP Info
--
r8BrgSTPInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R8BrgSTPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree information Table."
::= { r8Bridge 3 }
r8BrgSTPInfoEntry OBJECT-TYPE
SYNTAX R8BrgSTPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree information Entry"
INDEX { r8Index ,
r8BrgGroupID ,
r8STPIndex }
::= { r8BrgSTPInfo 1 }
R8BrgSTPInfoEntry ::= SEQUENCE {
r8STPIndex INTEGER,
r8STPName DisplayString,
r8STPBridgeID DisplayString,
r8STPHelloTime INTEGER,
r8STPMaxAgingTime INTEGER,
r8STPForwardDelay INTEGER,
r8STPRootCost INTEGER
}
r8STPIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"STP index"
::= { r8BrgSTPInfoEntry 3 }
r8STPName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning tree Name"
::= { r8BrgSTPInfoEntry 4 }
r8STPBridgeID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning tree Bridge Id"
::= { r8BrgSTPInfoEntry 5 }
r8STPHelloTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Hello Time interval"
::= { r8BrgSTPInfoEntry 6 }
r8STPMaxAgingTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Maximum Aging Time interval"
::= { r8BrgSTPInfoEntry 7 }
r8STPForwardDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Spanning Tree Forward Delay Time interval"
::= { r8BrgSTPInfoEntry 8 }
r8STPRootCost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Spanning Tree Post Cost"
::= { r8BrgSTPInfoEntry 9 }
--
-- OCT-RT-B STP Port Info
--
r8BrgStpPortInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R8BrgStpPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Spanning Tree Port information Table."
::= { r8Bridge 4 }
r8BrgStpPortInfoEntry OBJECT-TYPE
SYNTAX R8BrgStpPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Spanning Tree Port information Entry"
INDEX { r8Index ,
r8BrgGroupID ,
r8StpPortIndex }
::= { r8BrgStpPortInfo 1 }
R8BrgStpPortInfoEntry ::= SEQUENCE {
r8StpPortIndex INTEGER,
r8StpPortName DisplayString,
r8StpState INTEGER,
r8StpPriority INTEGER,
r8StpCost INTEGER,
r8StpEdgePort INTEGER,
r8StpLinkType INTEGER,
r8StpRootPort INTEGER
}
r8StpPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"STP Port Number Index"
::= { r8BrgStpPortInfoEntry 3 }
r8StpPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port Name"
::= { r8BrgStpPortInfoEntry 4 }
r8StpState OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
listen(2),
learn(3),
forward(4),
block(5),
down(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port state"
::= { r8BrgStpPortInfoEntry 5 }
r8StpPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r8BrgStpPortInfoEntry 6 }
r8StpCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r8BrgStpPortInfoEntry 7 }
r8StpEdgePort OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r8BrgStpPortInfoEntry 8 }
r8StpLinkType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
shared(1),
p-to-p(2),
auto(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STP Port priority"
::= { r8BrgStpPortInfoEntry 9 }
r8StpRootPort OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stp Port root status"
::= { r8BrgStpPortInfoEntry 10 }
--
-- OCT-RT-B Bridge Add or Delete Interface Table
--
r8BrgAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R8BrgAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or delete interface to bridge group Table."
::= { r8Bridge 5 }
r8BrgAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R8BrgAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or delete interface to bridge group Entry"
INDEX { r8Index }
::= { r8BrgAddDelInterface 1 }
R8BrgAddDelInterfaceEntry ::= SEQUENCE {
r8BrgAddDelBrgName DisplayString,
r8BrgAddDelInterfaceName DisplayString,
r8BrgAddDelInterfaceCMD INTEGER
}
r8BrgAddDelBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge Group Name"
::= { r8BrgAddDelInterfaceEntry 2 }
r8BrgAddDelInterfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1-8/wan1-64/wanX pvc1-16)"
::= { r8BrgAddDelInterfaceEntry 3 }
r8BrgAddDelInterfaceCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add interface to Bridge Mode or (delete)add interface
to router mode"
::= { r8BrgAddDelInterfaceEntry 4 }
--
-- OCT-RT-B Interface Control Table
--
r8Interface OBJECT IDENTIFIER ::= { oct-rt-b-card 4 }
--
-- OCT-RT-B LAN
--
r8IntfLAN OBJECT IDENTIFIER ::= { r8Interface 1 }
--
-- R8 LAN Config Table
--
r8LanCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8LanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LAN Config Table."
::= { r8IntfLAN 1 }
r8LanCFGEntry OBJECT-TYPE
SYNTAX R8LanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LAN Config Entry"
INDEX { r8Index ,
r8LanIndex }
::= { r8LanCFG 1 }
R8LanCFGEntry ::= SEQUENCE {
r8LanIndex INTEGER,
r8LanIPAddr DisplayString,
-- r8LanAliasIPAddr1
-- DisplayString,
-- r8LanAliasIPAddr2
-- DisplayString,
-- r8LanAliasIPAddr3
-- DisplayString,
-- r8LanAliasIPAddr4
-- DisplayString,
-- r8LanAliasIPAddr5
-- DisplayString,
r8LanRoutingProtocol INTEGER,
r8LanLayer2Protocol INTEGER,
r8LanSpeed INTEGER,
r8LanInterfaceMode INTEGER,
r8LanInboundPolicy DisplayString,
r8LanOutboundPolicy DisplayString,
r8LanStatus DisplayString
}
r8LanIndex OBJECT-TYPE
SYNTAX INTEGER {
lan1(1),
lan2(2),
lan3(3),
lan4(4),
lan5(5),
lan6(6),
lan7(7),
lan8(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Index"
::= { r8LanCFGEntry 2 }
r8LanIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r8LanCFGEntry 3 }
-- r8LanAliasIPAddr1 OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8LanCFGEntry 4 }
--
-- r8LanAliasIPAddr2 OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8LanCFGEntry 5 }
--
-- r8LanAliasIPAddr3 OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8LanCFGEntry 6 }
--
-- r8LanAliasIPAddr4 OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8LanCFGEntry 7 }
--
-- r8LanAliasIPAddr5 OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Lan alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8LanCFGEntry 8 }
r8LanRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table"
::= { r8LanCFGEntry 9 }
r8LanLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
no(0),
ethernet(1),
fast-ethernet(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Layer2 Protocol"
::= { r8LanCFGEntry 10 }
r8LanSpeed OBJECT-TYPE
SYNTAX INTEGER {
no(0),
half-duplex-10M(1),
full-duplex-10M(2),
half-duplex-100M(3),
full-duplex-100M(4),
auto-negotiation(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Speed(10/100Mb ; half/full)"
::= { r8LanCFGEntry 11 }
r8LanInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Interface Mode"
::= { r8LanCFGEntry 12 }
r8LanInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan inbound policy (off to disable access control)"
::= { r8LanCFGEntry 13 }
r8LanOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan outbound policy (off to disable access control)"
::= { r8LanCFGEntry 14 }
r8LanStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lan Status"
::= { r8LanCFGEntry 15 }
--
-- OCT-RT-B Add or Delete Lan Alias IP Table
--
-- r8AddDelAliasIP OBJECT-TYPE
-- SYNTAX SEQUENCE OF R8AddDelAliasIPEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Add or Delete Lan Alias IP Table."
-- ::= { r8IntfLAN 2 }
--
-- r8AddDelAliasIPEntry OBJECT-TYPE
-- SYNTAX R8AddDelAliasIPEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Add or Delete Lan Alias IP Entry"
-- INDEX { r8Index }
-- ::= { r8AddDelAliasIP 1 }
--
-- R8AddDelAliasIPEntry ::=
-- SEQUENCE {
-- r8AliasIPLanIndex
-- INTEGER,
-- r8AliasIPAddr
-- DisplayString,
-- r8AliasIPAddrCMD
-- INTEGER
-- }
--
-- r8AliasIPLanIndex OBJECT-TYPE
-- SYNTAX INTEGER{
-- lan1(1),
-- lan2(2),
-- lan3(3),
-- lan4(4),
-- lan5(5),
-- lan6(6),
-- lan7(7),
-- lan8(8)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Lan Index"
-- ::= { r8AddDelAliasIPEntry 2 }
--
-- r8AliasIPAddr OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..20))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Alias IP Address(xxx.xxx.xxx.xxx/xx)"
-- ::= { r8AddDelAliasIPEntry 3 }
--
-- r8AliasIPAddrCMD OBJECT-TYPE
-- SYNTAX INTEGER{
-- add(1),
-- delete(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Add or Delete Alias IP Address"
-- ::= { r8AddDelAliasIPEntry 4 }
--
-- OCT-RT-B WAN
--
r8IntfWAN OBJECT IDENTIFIER ::= { r8Interface 2 }
--
-- OCT-RT-B WAN Config Table
--
r8WanCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface WAN(1-64) Config Table."
::= { r8IntfWAN 1 }
r8WanCFGEntry OBJECT-TYPE
SYNTAX R8WanCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interface WAN(1-64) Config Entry"
INDEX { r8Index ,
r8WanIndex }
::= { r8WanCFG 1 }
R8WanCFGEntry ::= SEQUENCE {
r8WanIndex INTEGER,
r8WanIPAddr DisplayString,
r8WanRoutingProtocol INTEGER,
r8WanNatNapt INTEGER,
r8WanNumberOfTimeSlots INTEGER,
r8WanLayer2Protocol INTEGER,
r8WanInterfaceMode INTEGER,
r8WanInboundPolicy DisplayString,
r8WanOutboundPolicy DisplayString,
r8WanStatus INTEGER
}
r8WanIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface WAN1-WAN2"
::= { r8WanCFGEntry 2 }
r8WanIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r8WanCFGEntry 3 }
r8WanRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN Routing Protocol"
::= { r8WanCFGEntry 4 }
r8WanNatNapt OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
nat(2),
napt(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN NAT/NAPT Function"
::= { r8WanCFGEntry 5 }
r8WanNumberOfTimeSlots OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of TimeSlots for this WAN"
::= { r8WanCFGEntry 6 }
r8WanLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
no(0),
ppp(3),
hdlc(4),
frame-relay(5),
cisco-hdlc(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lan Layer2 Protocol"
::= { r8WanCFGEntry 7 }
r8WanInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Interface Mode"
::= { r8WanCFGEntry 8 }
r8WanInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan inbound policy (off to disable access control)"
::= { r8WanCFGEntry 9 }
r8WanOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan outbound policy (off to disable access control)"
::= { r8WanCFGEntry 10 }
r8WanStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Status"
::= { r8WanCFGEntry 11 }
--
-- OCT-RT-B WAN Cisco Hdlc Config Table
--
r8WanCiscoHdlc OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanCiscoHdlcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Cisco Hdlc Config Table."
::= { r8IntfWAN 2 }
r8WanCiscoHdlcEntry OBJECT-TYPE
SYNTAX R8WanCiscoHdlcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Cisco Hdlc Config Entry"
INDEX { r8Index ,
r8WanIndex }
::= { r8WanCiscoHdlc 1 }
R8WanCiscoHdlcEntry ::= SEQUENCE {
r8WanChdlcInterval INTEGER,
r8WanChdlcTimeout INTEGER,
r8WanChdlcCMD INTEGER
}
r8WanChdlcInterval OBJECT-TYPE
SYNTAX INTEGER (0 | 1..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Keepalive interval (1-3600, default is 10 secs)"
::= { r8WanCiscoHdlcEntry 3 }
r8WanChdlcTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface restart timeout(secs, should be multiple of interval)"
::= { r8WanCiscoHdlcEntry 4 }
r8WanChdlcCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
set(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Cisco Hdlc"
::= { r8WanCiscoHdlcEntry 5 }
--
-- OCT-RT-B WAN Frame Relay Config Table
--
r8WanFrameRelay OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanFrameRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Frame Relay Config Table."
::= { r8IntfWAN 3 }
r8WanFrameRelayEntry OBJECT-TYPE
SYNTAX R8WanFrameRelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Frame Relay Config Entry"
INDEX { r8Index ,
r8WanIndex }
::= { r8WanFrameRelay 1 }
R8WanFrameRelayEntry ::= SEQUENCE {
r8WanFRLMIType INTEGER,
r8WanFRN391 INTEGER,
r8WanFRN392 INTEGER,
r8WanFRN393 INTEGER,
r8WanFRT391 INTEGER
}
r8WanFRLMIType OBJECT-TYPE
SYNTAX INTEGER {
na(0),
q933(1),
ansi(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame Relay LMI protocol (ansi/q933)"
::= { r8WanFrameRelayEntry 3 }
r8WanFRN391 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI full-status polling interval (1~255)"
::= { r8WanFrameRelayEntry 4 }
r8WanFRN392 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI error threshold (1~10)"
::= { r8WanFrameRelayEntry 5 }
r8WanFRN393 OBJECT-TYPE
SYNTAX INTEGER (0 | 1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI monitored event threshold (1~10)"
::= { r8WanFrameRelayEntry 6 }
r8WanFRT391 OBJECT-TYPE
SYNTAX INTEGER (0 | 5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LMI link integrity polling interval (5~30)"
::= { r8WanFrameRelayEntry 7 }
--
-- OCT-RT-B WAN PVC
--
r8WanPVC OBJECT IDENTIFIER ::= { r8IntfWAN 4 }
--
-- OCT-RT-B WAN PVC Function Table
--
r8WanAddDelPVC OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanAddDelPVCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC Table"
::= { r8WanPVC 1 }
r8WanAddDelPVCEntry OBJECT-TYPE
SYNTAX R8WanAddDelPVCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC Entry"
INDEX { r8Index }
::= { r8WanAddDelPVC 1 }
R8WanAddDelPVCEntry ::= SEQUENCE {
r8PvcWanIndex INTEGER,
r8PvcNum INTEGER,
r8PvcDLCI INTEGER,
r8PvcCIR INTEGER,
r8PvcBc INTEGER,
r8PvcBe INTEGER,
r8PvcQdepth INTEGER,
r8WanPvcCMD INTEGER
}
r8PvcWanIndex OBJECT-TYPE
SYNTAX INTEGER (0 | 1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Wan number (wan1-wan64)"
::= { r8WanAddDelPVCEntry 2 }
r8PvcNum OBJECT-TYPE
SYNTAX INTEGER (0 | 1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC number (pvc1-pvc16)"
::= { r8WanAddDelPVCEntry 3 }
r8PvcDLCI OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC's DLCI (16~991)"
::= { r8WanAddDelPVCEntry 4 }
r8PvcCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Information Rate (kbps)"
::= { r8WanAddDelPVCEntry 5 }
r8PvcBc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Burst Size (kbits)"
::= { r8WanAddDelPVCEntry 6 }
r8PvcBe OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Excess Burst Size (kbits)"
::= { r8WanAddDelPVCEntry 7 }
r8PvcQdepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max. queue length"
::= { r8WanAddDelPVCEntry 8 }
r8WanPvcCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
add-pvc(1),
delete-pvc(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or Delete Frame Relay PVC for this wan interface"
::= { r8WanAddDelPVCEntry 9 }
--
-- OCT-RT-B WAN PVC Config Table
--
r8WanPvcCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanPvcCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN PVC Config Table"
::= { r8WanPVC 2 }
r8WanPvcCFGEntry OBJECT-TYPE
SYNTAX R8WanPvcCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN PVC Config Entry"
INDEX { r8Index ,
r8WanIndex ,
r8PvcIndex }
::= { r8WanPvcCFG 1 }
R8WanPvcCFGEntry ::= SEQUENCE {
r8PvcIndex INTEGER,
r8WanPvcState INTEGER,
r8WanPvcIPAddr DisplayString,
r8WanPvcRoutingProtocol INTEGER,
r8WanPvcNatNapt INTEGER,
r8WanPvcInterfaceMode INTEGER,
r8WanPvcDLCI INTEGER,
r8WanPvcCIR INTEGER,
r8WanPvcBc INTEGER,
r8WanPvcBe INTEGER,
r8WanPvcQdepth INTEGER,
r8WanPvcInboundPolicy DisplayString,
r8WanPvcOutboundPolicy DisplayString
}
r8PvcIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PVC number (pvc1-pvc16)"
::= { r8WanPvcCFGEntry 3 }
r8WanPvcState OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN PVC State"
::= { r8WanPvcCFGEntry 4 }
r8WanPvcIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC IP address (xxx.xxx.xxx.xxx/xx)"
::= { r8WanPvcCFGEntry 5 }
r8WanPvcRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC Routing Protocol(OSPF enable/disable in r2OspfIntfAdminSetup Table)"
::= { r8WanPvcCFGEntry 6 }
r8WanPvcNatNapt OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
nat(2),
napt(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN PVC NAT/NAPT Function"
::= { r8WanPvcCFGEntry 7 }
r8WanPvcInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN PVC Interface Mode"
::= { r8WanPvcCFGEntry 8 }
r8WanPvcDLCI OBJECT-TYPE
SYNTAX INTEGER (16..991)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PVC's DLCI (16~991)"
::= { r8WanPvcCFGEntry 9 }
r8WanPvcCIR OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Information Rate (kbps)"
::= { r8WanPvcCFGEntry 10 }
r8WanPvcBc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Committed Burst Size (kbits)"
::= { r8WanPvcCFGEntry 11 }
r8WanPvcBe OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Excess Burst Size (kbits)"
::= { r8WanPvcCFGEntry 12 }
r8WanPvcQdepth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max. queue length"
::= { r8WanPvcCFGEntry 13 }
r8WanPvcInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Pvc inbound policy (off to disable access control)"
::= { r8WanPvcCFGEntry 14 }
r8WanPvcOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Pvc outbound policy (off to disable access control)"
::= { r8WanPvcCFGEntry 15 }
--
-- OCT-RT-B WAN Channel Map
--
r8WanChannelMap OBJECT IDENTIFIER ::= { r8IntfWAN 5 }
--
-- OCT-RT-B WAN Set Channel Map Control
--
r8WanSetMap OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanSetMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Set Channel Map Table"
::= { r8WanChannelMap 1 }
r8WanSetMapEntry OBJECT-TYPE
SYNTAX R8WanSetMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Set Channel Map Entry"
INDEX { r8Index }
::= { r8WanSetMap 1 }
R8WanSetMapEntry ::= SEQUENCE {
r8MapWanNumber INTEGER,
r8StartTimeSlot INTEGER,
r8ChannelNumber INTEGER,
r8MapCommand INTEGER
}
r8MapWanNumber OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Index(wan1~wan64)"
::= { r8WanSetMapEntry 2 }
r8StartTimeSlot OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set start time slot number"
::= { r8WanSetMapEntry 3 }
r8ChannelNumber OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set channel number"
::= { r8WanSetMapEntry 4 }
r8MapCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
clear(1),
set(2),
clrSet(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Map Command"
::= { r8WanSetMapEntry 5 }
--
-- OCT-RT-B WAN Channel Map Info Table
--
r8ChannelMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Channel Map Config Table"
::= { r8WanChannelMap 2 }
r8ChannelMapEntry OBJECT-TYPE
SYNTAX R8ChannelMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"WAN Channel Map Config Entry"
INDEX { r8Index ,
r8TimeSlotIndex }
::= { r8ChannelMapTable 1 }
R8ChannelMapEntry ::= SEQUENCE {
r8TimeSlotIndex INTEGER,
r8MapToWanNum WanID
}
r8TimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot number"
::= { r8ChannelMapEntry 2 }
r8MapToWanNum OBJECT-TYPE
SYNTAX WanID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot number"
::= { r8ChannelMapEntry 3 }
--
-- OCT-RT-B WAN QoS Table
--
r8WanQoS OBJECT IDENTIFIER ::= { r8IntfWAN 6 }
--
-- R8 WAN Qos Policy Table
--
r8WanQosPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanQosPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Table."
::= { r8WanQoS 1 }
r8WanQosPolicyEntry OBJECT-TYPE
SYNTAX R8WanQosPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Entry"
INDEX { r8Index ,
r8WanIndex ,
r8WanQosPolicyNumber }
::= { r8WanQosPolicyTable 1 }
R8WanQosPolicyEntry ::= SEQUENCE {
r8WanQosPolicyNumber INTEGER,
r8WanQosPolicySrcIP DisplayString,
r8WanQosPolicyDstIP DisplayString,
r8WanQosPolicyProtocol DisplayString,
r8WanQosPolicyRate DisplayString,
r8WanQosPolicySrcPort DisplayString,
r8WanQosPolicyDstPort DisplayString,
r8WanQosPolicyDSCP DisplayString
}
r8WanQosPolicyNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Qos Policy Number"
::= { r8WanQosPolicyEntry 3 }
r8WanQosPolicySrcIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Source IP/Perfix"
::= { r8WanQosPolicyEntry 4 }
r8WanQosPolicyDstIP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Destination IP/Perfix"
::= { r8WanQosPolicyEntry 5 }
r8WanQosPolicyProtocol OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"WAN Qos Policy Protocol"
::= { r8WanQosPolicyEntry 6 }
r8WanQosPolicyRate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Rate"
::= { r8WanQosPolicyEntry 7 }
r8WanQosPolicySrcPort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Source Port"
::= { r8WanQosPolicyEntry 8 }
r8WanQosPolicyDstPort OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Destination Port"
::= { r8WanQosPolicyEntry 9 }
r8WanQosPolicyDSCP OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Qos Policy DSCP Information"
::= { r8WanQosPolicyEntry 10 }
--
-- R8 WAN Qos Policy Control Table
--
r8WanQosPolicyControl OBJECT IDENTIFIER ::= { r8WanQoS 2 }
--
-- R8 WAN Qos Append and Insert Policy Table
--
r8WanQosAppendAndInsertPolicy OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanQosAppendAndInsertPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append od Insert a traffic control policy Table."
::= { r8WanQosPolicyControl 1 }
r8WanQosAppendAndInsertPolicyEntry OBJECT-TYPE
SYNTAX R8WanQosAppendAndInsertPolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append od Insert a traffic control policy Entry"
INDEX { r8Index }
::= { r8WanQosAppendAndInsertPolicy 1 }
R8WanQosAppendAndInsertPolicyEntry ::= SEQUENCE {
r8WanAppInstPolicyWanNum INTEGER (1..64),
r8WanAppInstPolicySrcIP DisplayString (SIZE (0..20)),
r8WanAppInstPolicySrcIPPrefix DisplayString (SIZE (0..2)),
r8WanAppInstPolicyDstIP DisplayString (SIZE (0..20)),
r8WanAppInstPolicyDstIPPrefix DisplayString (SIZE (0..2)),
r8WanAppInstPolicySrcPort DisplayString (SIZE (0..25)),
r8WanAppInstPolicyDstPort DisplayString (SIZE (0..25)),
r8WanAppInstPolicyProtocol DisplayString (SIZE (0..10)),
r8WanAppInstPolicyRate DisplayString (SIZE (0..25)),
r8WanAppInstPolicyRateType INTEGER,
r8WanInstPolicyNum INTEGER (0..32),
r8WanAppInstPolicyDSCP DisplayString (SIZE (0..255)),
r8WanAppInstPolicyCommand INTEGER
}
r8WanAppInstPolicyWanNum OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Number(Wan 1~64)"
::= { r8WanQosAppendAndInsertPolicyEntry 2 }
r8WanAppInstPolicySrcIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source IP(xxx.xxx.xxx.xxx)"
::= { r8WanQosAppendAndInsertPolicyEntry 3 }
r8WanAppInstPolicySrcIPPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source IP Prefix(skip if src_ip is 'any')"
::= { r8WanQosAppendAndInsertPolicyEntry 4 }
r8WanAppInstPolicyDstIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination IP(xxx.xxx.xxx.xxx)"
::= { r8WanQosAppendAndInsertPolicyEntry 5 }
r8WanAppInstPolicyDstIPPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination IP Prefix(skip if dst_ip is 'any')"
::= { r8WanQosAppendAndInsertPolicyEntry 6 }
r8WanAppInstPolicySrcPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Source Port(any or min[-max] only for TCP/UDP, (no space before and after '-')"
::= { r8WanQosAppendAndInsertPolicyEntry 7 }
r8WanAppInstPolicyDstPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Destination Port(any or min[-max] only for TCP/UDP, (no space before and after '-')"
::= { r8WanQosAppendAndInsertPolicyEntry 8 }
r8WanAppInstPolicyProtocol OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Protocol(TCP or UDP or ICMP or Any or 0~255)"
::= { r8WanQosAppendAndInsertPolicyEntry 9 }
r8WanAppInstPolicyRate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..25))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Rate(Committed access rate in min[-max] format, (no space before and after '-') )"
::= { r8WanQosAppendAndInsertPolicyEntry 10 }
r8WanAppInstPolicyRateType OBJECT-TYPE
SYNTAX INTEGER {
kbps(1),
mbps(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Rate Type(type of bandwidth for rate in bits per sec)"
::= { r8WanQosAppendAndInsertPolicyEntry 11 }
r8WanInstPolicyNum OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy number before which new policy will be inserted"
::= { r8WanQosAppendAndInsertPolicyEntry 12 }
r8WanAppInstPolicyCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
append(1),
insert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Qos Policy Command"
::= { r8WanQosAppendAndInsertPolicyEntry 13 }
r8WanAppInstPolicyDSCP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optional Diffserv code point value(s) in decimal (space to separate DSCP values, but no space for '-')"
::= { r8WanQosAppendAndInsertPolicyEntry 14 }
--
-- R8 WAN Qos Delete Policy Table
--
r8WanQosDeletePolicy OBJECT-TYPE
SYNTAX SEQUENCE OF R8WanQosDeletePolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete a traffic control policy Table."
::= { r8WanQosPolicyControl 2 }
r8WanQosDeletePolicyEntry OBJECT-TYPE
SYNTAX R8WanQosDeletePolicyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete a traffic control policy Entry"
INDEX { r8Index }
::= { r8WanQosDeletePolicy 1 }
R8WanQosDeletePolicyEntry ::= SEQUENCE {
r8WanDelPolicyWanNum INTEGER (1..64),
r8WanDelPolicyNumber INTEGER (1..32),
r8WanDelPolicyCommand INTEGER
}
r8WanDelPolicyWanNum OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wan Number(Wan 1~64)"
::= { r8WanQosDeletePolicyEntry 2 }
r8WanDelPolicyNumber OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Policy Number(1~32)"
::= { r8WanQosDeletePolicyEntry 3 }
r8WanDelPolicyCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete Policy Command"
::= { r8WanQosDeletePolicyEntry 4 }
--
-- OCT-RT-B Virtual Interface
--
r8IntfVirtual OBJECT IDENTIFIER ::= { r8Interface 3 }
--
-- OCT-RT-B Virtual Interface Config
--
r8VirtualIntfCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8VirtualIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Configuration Table."
::= { r8IntfVirtual 1 }
r8VirtualIntfCFGEntry OBJECT-TYPE
SYNTAX R8VirtualIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Configuration Entry"
INDEX { r8Index ,
r8VIntfIndex }
::= { r8VirtualIntfCFG 1 }
R8VirtualIntfCFGEntry ::= SEQUENCE {
r8VIntfIndex INTEGER,
r8VIntfName DisplayString,
r8VIntfRoutingProtocol INTEGER,
r8VIntfLayer2Protocol INTEGER,
r8VIntfInterfaceMode INTEGER,
r8VIntfInboundPolicy DisplayString,
r8VIntfOutboundPolicy DisplayString,
r8VIntfStatus INTEGER
}
r8VIntfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual interface index"
::= { r8VirtualIntfCFGEntry 2 }
r8VIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual interface name"
::= { r8VirtualIntfCFGEntry 3 }
r8VIntfRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER {
rip1(1),
rip2(2),
ospf(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface Routing Protocol(OSPF enable/disable in r8OspfIntfAdminSetup Table)"
::= { r8VirtualIntfCFGEntry 4 }
r8VIntfLayer2Protocol OBJECT-TYPE
SYNTAX INTEGER {
ppp(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Layer2 Protocol"
::= { r8VirtualIntfCFGEntry 5 }
r8VIntfInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
null(0),
router(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Mode of Virtual Interface"
::= { r8VirtualIntfCFGEntry 6 }
r8VIntfInboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface inbound policy (off to disable access control)"
::= { r8VirtualIntfCFGEntry 7 }
r8VIntfOutboundPolicy OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface outbound policy (off to disable access control)"
::= { r8VirtualIntfCFGEntry 8 }
r8VIntfStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Status"
::= { r8VirtualIntfCFGEntry 9 }
--
-- OCT-RT-B Policy
--
r8Policy OBJECT IDENTIFIER ::= { oct-rt-b-card 5 }
--
-- R8 Filter Info
--
r8FilterInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R8FilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"filter information Table"
::= { r8Policy 1 }
r8FilterInfoEntry OBJECT-TYPE
SYNTAX R8FilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"filter information Entry"
INDEX { r8Index ,
r8FilterIndex ,
r8RuleIndex }
::= { r8FilterInfo 1 }
R8FilterInfoEntry ::= SEQUENCE {
r8FilterIndex INTEGER,
r8RuleIndex INTEGER,
r8FilterName DisplayString,
r8FilterAction INTEGER,
r8FilterSrcAddr DisplayString,
r8FilterDestAddr DisplayString,
r8FilterProtocol INTEGER,
r8FilterPortLow INTEGER,
r8FilterPortHigh INTEGER
}
r8FilterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Filter List Index "
::= { r8FilterInfoEntry 2 }
r8RuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"filter rule index"
::= { r8FilterInfoEntry 3 }
r8FilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"filter list Name"
::= { r8FilterInfoEntry 4 }
r8FilterAction OBJECT-TYPE
SYNTAX INTEGER{
deny(1),
permit(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Filter action"
::= { r8FilterInfoEntry 5 }
r8FilterSrcAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"source address of filter action (xx.xx.xx.xx/xx)"
::= { r8FilterInfoEntry 6 }
r8FilterDestAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"destination address of filter action (xx.xx.xx.xx/xx)"
::= { r8FilterInfoEntry 7 }
r8FilterProtocol OBJECT-TYPE
SYNTAX INTEGER{
tcp(1),
udp(2),
icmp(3),
any(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"protocol of filter action"
::= { r8FilterInfoEntry 8 }
r8FilterPortLow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Low port of the port range for TCP/UDP"
::= { r8FilterInfoEntry 9 }
r8FilterPortHigh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"High port of the port range for TCP/UDP"
::= { r8FilterInfoEntry 10 }
--
-- OCT-RT-B Mac Filter Info
--
r8MacFilterInfo OBJECT-TYPE
SYNTAX SEQUENCE OF R8MacFilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Mac filter information Table"
::= { r8Policy 2 }
r8MacFilterInfoEntry OBJECT-TYPE
SYNTAX R8MacFilterInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Mac filter information Entry"
INDEX { r8Index ,
r8MacFilterIndex ,
r8MacFilterRuleIndex }
::= { r8MacFilterInfo 1 }
R8MacFilterInfoEntry ::= SEQUENCE {
r8MacFilterIndex INTEGER,
r8MacFilterRuleIndex INTEGER,
r8MacFilterName DisplayString,
r8MacFilterMacAddress DisplayString
}
r8MacFilterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter List Index "
::= { r8MacFilterInfoEntry 2 }
r8MacFilterRuleIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MAc Filter rule index"
::= { r8MacFilterInfoEntry 3 }
r8MacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter list Name"
::= { r8MacFilterInfoEntry 4 }
r8MacFilterMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mac Filter Mac Address"
::= { r8MacFilterInfoEntry 5 }
--
-- OCT-RT-B Filter Control
--
r8FilterControl OBJECT IDENTIFIER ::= { r8Policy 3 }
--
-- R8 Create & Destroy Filter list Table
--
r8CreateDestroyFilter OBJECT-TYPE
SYNTAX SEQUENCE OF R8CreateDestroyFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Filter List Table"
::= { r8FilterControl 1 }
r8CreateDestroyFilterEntry OBJECT-TYPE
SYNTAX R8CreateDestroyFilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Filter List Entry"
INDEX { r8Index }
::= { r8CreateDestroyFilter 1 }
R8CreateDestroyFilterEntry ::= SEQUENCE {
r8CreDesFilterName DisplayString,
r8CreDesFilterCMD INTEGER
}
r8CreDesFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filter List Name"
::= { r8CreateDestroyFilterEntry 2 }
r8CreDesFilterCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
create-filter(1),
destroy-filter(2),
create-mac-filter(3),
destroy-mac-filter(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Filter List Command"
::= { r8CreateDestroyFilterEntry 3 }
--
-- R8 Add Filter Rule
--
r8AddFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append filter rule Table"
::= { r8FilterControl 2 }
r8AddFilterRuleEntry OBJECT-TYPE
SYNTAX R8AddFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append filter rule Entry"
INDEX { r8Index }
::= { r8AddFilterRule 1 }
R8AddFilterRuleEntry ::= SEQUENCE {
r8AddFilterName DisplayString,
r8AddFilterAction INTEGER,
r8AddFilterSrcAddr DisplayString,
r8AddFilterDestAddr DisplayString,
r8AddFilterProtocol INTEGER,
r8AddFilterPortLow INTEGER,
r8AddFilterPortHigh INTEGER,
r8AddFilterRuleCMD INTEGER
}
r8AddFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Filter List Name"
::= { r8AddFilterRuleEntry 2 }
r8AddFilterAction OBJECT-TYPE
SYNTAX INTEGER{
deny(1),
permit(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Filter action"
::= { r8AddFilterRuleEntry 3 }
r8AddFilterSrcAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"source address of filter action (xx.xx.xx.xx/xx)"
::= { r8AddFilterRuleEntry 4 }
r8AddFilterDestAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"destination address of filter action (xx.xx.xx.xx/xx)"
::= { r8AddFilterRuleEntry 5 }
r8AddFilterProtocol OBJECT-TYPE
SYNTAX INTEGER{
tcp(1),
udp(2),
icmp(3),
any(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"protocol of filter action"
::= { r8AddFilterRuleEntry 6 }
r8AddFilterPortLow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low port of the port range for TCP/UDP"
::= { r8AddFilterRuleEntry 7 }
r8AddFilterPortHigh OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"High port of the port range for TCP/UDP"
::= { r8AddFilterRuleEntry 8 }
r8AddFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
append(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Append Filter rule"
::= { r8AddFilterRuleEntry 9 }
--
-- R8 Add Mac Filter Rule
--
r8AddMacFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append Mac filter rule Table"
::= { r8FilterControl 3 }
r8AddMacFilterRuleEntry OBJECT-TYPE
SYNTAX R8AddMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Append Mac filter rule Entry"
INDEX { r8Index }
::= { r8AddMacFilterRule 1 }
R8AddMacFilterRuleEntry ::= SEQUENCE {
r8AddMacFilterName DisplayString,
r8AddMacFilterMacAddr DisplayString,
r8AddMacFilterRuleCMD INTEGER
}
r8AddMacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mac Filter List Name"
::= { r8AddMacFilterRuleEntry 2 }
r8AddMacFilterMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mac Filter Mac address"
::= { r8AddMacFilterRuleEntry 3 }
r8AddMacFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
append(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Append Mac Filter rule"
::= { r8AddMacFilterRuleEntry 4 }
--
-- R8 Delete Filter Rule
--
r8DelFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R8DelFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete filter rule Table"
::= { r8FilterControl 4 }
r8DelFilterRuleEntry OBJECT-TYPE
SYNTAX R8DelFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete filter rule Entry"
INDEX { r8Index }
::= { r8DelFilterRule 1 }
R8DelFilterRuleEntry ::= SEQUENCE {
r8DelFilterName DisplayString,
r8DelStartIndex INTEGER,
r8DelEndIndex INTEGER,
r8DelFilterRuleCMD INTEGER
}
r8DelFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"filter list Name"
::= { r8DelFilterRuleEntry 2 }
r8DelStartIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"start index of list which will be deleted"
::= { r8DelFilterRuleEntry 3 }
r8DelEndIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"end index of list which will be deleted"
::= { r8DelFilterRuleEntry 4 }
r8DelFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"delete filter rule command"
::= { r8DelFilterRuleEntry 5 }
--
-- R8 Delete Mac Filter Rule
--
r8DelMacFilterRule OBJECT-TYPE
SYNTAX SEQUENCE OF R8DelMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete Mac filter rule Table"
::= { r8FilterControl 5 }
r8DelMacFilterRuleEntry OBJECT-TYPE
SYNTAX R8DelMacFilterRuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete Mac filter rule Entry"
INDEX { r8Index }
::= { r8DelMacFilterRule 1 }
R8DelMacFilterRuleEntry ::= SEQUENCE {
r8DelMacFilterName DisplayString,
r8DelMacFilterMacAddr DisplayString,
r8DelMacFilterRuleCMD INTEGER
}
r8DelMacFilterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac filter list Name"
::= { r8DelMacFilterRuleEntry 2 }
r8DelMacFilterMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac address"
::= { r8DelMacFilterRuleEntry 3 }
r8DelMacFilterRuleCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"delete mac filter rule command"
::= { r8DelMacFilterRuleEntry 4 }
--
-- OCT-RT-B Route
--
r8Route OBJECT IDENTIFIER ::= { oct-rt-b-card 6 }
--
-- OCT-RT-B Static Route Table
--
r8StaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Static Route Table"
::= { r8Route 1 }
r8StaticRouteEntry OBJECT-TYPE
SYNTAX R8StaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Static Route Entry"
INDEX { r8Index ,
r8RouteIndex }
::= { r8StaticRouteTable 1 }
R8StaticRouteEntry ::= SEQUENCE {
r8RouteIndex INTEGER,
r8StaticRouteNetAddr DisplayString,
r8StaticRouteNetMask DisplayString,
r8StaticRouteGatewayAddr DisplayString,
r8StaticRouteInterface DisplayString
}
r8RouteIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"routing table entry index"
::= { r8StaticRouteEntry 2 }
r8StaticRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route net Address"
::= { r8StaticRouteEntry 3 }
r8StaticRouteNetMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route net mask"
::= { r8StaticRouteEntry 4 }
r8StaticRouteGatewayAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route gateway Address"
::= { r8StaticRouteEntry 5 }
r8StaticRouteInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Static route output interface"
::= { r8StaticRouteEntry 6 }
--
-- OCT-RT-B Add Static Route
--
r8AddStaticRoute OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add static route Table"
::= { r8Route 2 }
r8AddStaticRouteEntry OBJECT-TYPE
SYNTAX R8AddStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add static route Entry"
INDEX { r8Index }
::= { r8AddStaticRoute 1 }
R8AddStaticRouteEntry ::= SEQUENCE {
r8AddRouteNetAddr DisplayString,
r8AddRouteGatewayAddr DisplayString,
r8AddRouteInterface DisplayString,
r8AddSataicRouteCMD INTEGER
}
r8AddRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route net Address(xxx.xxx.xxx.xxx/xx)"
::= { r8AddStaticRouteEntry 2 }
r8AddRouteGatewayAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route gateway Address(xxx.xxx.xxx.xxx)"
::= { r8AddStaticRouteEntry 3 }
r8AddRouteInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route output interface(lan1~2/wan1~wan64/wanX pvc1-16/brg_group)"
::= { r8AddStaticRouteEntry 4 }
r8AddSataicRouteCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" add static route "
::= { r8AddStaticRouteEntry 5 }
--
-- OCT-RT-B Delete Static Route
--
r8DelStaticRoute OBJECT-TYPE
SYNTAX SEQUENCE OF R8DelStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete static route Table"
::= { r8Route 3 }
r8DelStaticRouteEntry OBJECT-TYPE
SYNTAX R8DelStaticRouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete static route Entry"
INDEX { r8Index }
::= { r8DelStaticRoute 1 }
R8DelStaticRouteEntry ::= SEQUENCE {
r8DelRouteNetAddr DisplayString,
r8DelSataicRouteCMD INTEGER
}
r8DelRouteNetAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Static route net Address(xxx.xxx.xxx.xxx/xx)"
::= { r8DelStaticRouteEntry 2 }
r8DelSataicRouteCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
delete(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete static route"
::= { r8DelStaticRouteEntry 3 }
--
-- OCT-RT-B OSPF
--
r8OSPF OBJECT IDENTIFIER ::= { r8Route 4 }
--
-- OCT-RT-B OSPF General Table
--
r8OspfGereralTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8OspfGereralEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Route OSPF General Config Table"
::= { r8OSPF 1 }
r8OspfGereralEntry OBJECT-TYPE
SYNTAX R8OspfGereralEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Route OSPF General Config Entry"
INDEX { r8Index }
::= { r8OspfGereralTable 1 }
R8OspfGereralEntry ::= SEQUENCE {
r8OspfRedistribute DisplayString (SIZE (1..50)),
r8OspfRouterID DisplayString (SIZE (1..20))
}
r8OspfRedistribute OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..50))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Redistributes (kernel | static | connected | rip | default | none)"
::= { r8OspfGereralEntry 2 }
r8OspfRouterID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address(xxx.xxx.xxx.xxx) that identifies this OSPF router"
::= { r8OspfGereralEntry 3 }
--
-- OCT-RT-B OSPF Area
--
r8OspfArea OBJECT IDENTIFIER ::= { r8OSPF 2 }
--
-- R8 OSPF Area Config
--
r8OspfAreaCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8OspfAreaCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Area Config"
::= { r8OspfArea 1 }
r8OspfAreaCFGEntry OBJECT-TYPE
SYNTAX R8OspfAreaCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Area Config Entry"
INDEX { r8Index ,
r8OspfAreaCfgIndex }
::= { r8OspfAreaCFG 1 }
R8OspfAreaCFGEntry ::= SEQUENCE {
r8OspfAreaCfgIndex INTEGER,
r8OspfAreaCfgAreaID INTEGER,
r8OspfAreaCfgAuthenticationType INTEGER,
r8OspfAreaCfgAreaType INTEGER,
r8OspfAreaCfgCost INTEGER (0..16777215)
}
r8OspfAreaCfgIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OSPF Area Config Index"
::= { r8OspfAreaCFGEntry 2 }
r8OspfAreaCfgAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OSPF Area Config Area ID"
::= { r8OspfAreaCFGEntry 3 }
r8OspfAreaCfgAuthenticationType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
password(2),
md5(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication for an OSPF area"
::= { r8OspfAreaCFGEntry 4 }
r8OspfAreaCfgAreaType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
stub(2),
stub-no-summary(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Designates an area as a stub area"
::= { r8OspfAreaCFGEntry 5 }
r8OspfAreaCfgCost OBJECT-TYPE
SYNTAX INTEGER (0..16777215)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Assign a specific cost to the default summary route used"
::= { r8OspfAreaCFGEntry 6 }
--
-- OCT-RT-B OSPF Add & Delete Area
--
r8OspfAddDelArea OBJECT-TYPE
SYNTAX SEQUENCE OF R8OspfAddDelAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area"
::= { r8OspfArea 2 }
r8OspfAddDelAreaEntry OBJECT-TYPE
SYNTAX R8OspfAddDelAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area Entry"
INDEX { r8Index }
::= { r8OspfAddDelArea 1 }
R8OspfAddDelAreaEntry ::= SEQUENCE {
r8OspfAddDelAreaID INTEGER,
r8OspfAddDelAreaCommand INTEGER
}
r8OspfAddDelAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area ID"
::= { r8OspfAddDelAreaEntry 2 }
r8OspfAddDelAreaCommand OBJECT-TYPE
SYNTAX INTEGER {
no(0),
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add and Delete OSPF Area ID Command"
::= { r8OspfAddDelAreaEntry 3 }
--
-- OCT-RT-B OSPF Interface Table
--
r8OspfInterface OBJECT IDENTIFIER ::= { r8OSPF 3 }
--
-- OCT-RT-B OSPF Interface Config Table
--
r8OspfIntfCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8OspfIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Config"
::= { r8OspfInterface 1 }
r8OspfIntfCFGEntry OBJECT-TYPE
SYNTAX R8OspfIntfCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Config Entry"
INDEX { r8Index ,
r8OspfIntfIndex }
::= { r8OspfIntfCFG 1 }
R8OspfIntfCFGEntry ::= SEQUENCE {
r8OspfIntfIndex INTEGER,
r8OspfIntfName DisplayString (SIZE (0..20)),
r8OspfIntfAdminStatus INTEGER,
r8OspfIntfAreaID INTEGER,
r8OspfIntfNetworkType INTEGER,
r8OspfIntfLinkCost INTEGER (1..65535),
r8OspfIntfTransmitDelay INTEGER (1..65535),
r8OspfIntfRouterPriority INTEGER (0..255),
r8OspfIntfHelloInterval INTEGER (1..65535),
r8OspfIntfRouterDeadInterval INTEGER (1..65535),
r8OspfIntfRetransmitInterval INTEGER (1..65535),
r8OspfIntfAuthMD5KeyID-Key DisplayString (SIZE (0..20)),
r8OspfIntfAuthPasswordTextKey DisplayString (SIZE (0..8))
}
r8OspfIntfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Index"
::= { r8OspfIntfCFGEntry 2 }
r8OspfIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name(Lan1~2/Wan1~64/Wanxx Pvc1~16)"
::= { r8OspfIntfCFGEntry 3 }
r8OspfIntfAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
dsiable(1),
enable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The OSPF interface's administrative status"
::= { r8OspfIntfCFGEntry 4 }
r8OspfIntfAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A 32-bit integer uniquely identifying the area to which the interface connects."
::= { r8OspfIntfCFGEntry 5 }
r8OspfIntfNetworkType OBJECT-TYPE
SYNTAX INTEGER {
broadcast(1),
point-to-point(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The OSPF interface type."
::= { r8OspfIntfCFGEntry 6 }
r8OspfIntfLinkCost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Explicitly specify the link cost of sending a packet"
::= { r8OspfIntfCFGEntry 7 }
r8OspfIntfTransmitDelay OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for InfTransDelay value."
::= { r8OspfIntfCFGEntry 8 }
r8OspfIntfRouterPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RouterPriority integer value."
::= { r8OspfIntfCFGEntry 9 }
r8OspfIntfHelloInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds between hello packets sent."
::= { r8OspfIntfCFGEntry 10 }
r8OspfIntfRouterDeadInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for RouterDeadInterval timer."
::= { r8OspfIntfCFGEntry 11 }
r8OspfIntfRetransmitInterval OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of seconds for RxmtInterval timer value."
::= { r8OspfIntfCFGEntry 12 }
r8OspfIntfAuthMD5KeyID-Key OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface MD5 Authentication KeyID/Key(KeyID:1~255, Key:up to 16 chars)"
::= { r8OspfIntfCFGEntry 13 }
r8OspfIntfAuthPasswordTextKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Password Authentication Key"
::= { r8OspfIntfCFGEntry 14 }
--
-- OCT-RT-B OSPF Interface Admin Setup Table
--
r8OspfIntfAdminSetup OBJECT-TYPE
SYNTAX SEQUENCE OF R8OspfIntfAdminSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Admin Setup Table"
::= { r8OspfInterface 2 }
r8OspfIntfAdminSetupEntry OBJECT-TYPE
SYNTAX R8OspfIntfAdminSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OSPF Interface Admin Setup Entry"
INDEX { r8Index }
::= { r8OspfIntfAdminSetup 1 }
R8OspfIntfAdminSetupEntry ::= SEQUENCE {
r8OspfIntfAdminSetupIntfName DisplayString (SIZE (0..20)),
r8OspfIntfAdminSetupAreaID INTEGER,
r8OspfIntfAdminSetupCMD INTEGER
}
r8OspfIntfAdminSetupIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1~2/wan1~64/wanXX pvcXX)"
::= { r8OspfIntfAdminSetupEntry 2 }
r8OspfIntfAdminSetupAreaID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface OSPF Area ID"
::= { r8OspfIntfAdminSetupEntry 3 }
r8OspfIntfAdminSetupCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
disable-intf-ospf(1),
enable-intf-ospf(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface OSPF Admin Setup Command(Disable/Enable)"
::= { r8OspfIntfAdminSetupEntry 4 }
--
-- OCT-RT-B NAT
--
r8NAT OBJECT IDENTIFIER ::= { oct-rt-b-card 7 }
--
-- R8 NAT Interface Mode
--
r8NatIFMode OBJECT-TYPE
SYNTAX SEQUENCE OF R8NatIFModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT interface mode status Table"
::= { r8NAT 1 }
r8NatIFModeEntry OBJECT-TYPE
SYNTAX R8NatIFModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT interface mode status Entry"
INDEX { r8Index ,
r8NatIFIndex }
::= { r8NatIFMode 1 }
R8NatIFModeEntry ::= SEQUENCE {
r8NatIFIndex INTEGER,
r8NatIFName DisplayString,
r8NatMode INTEGER
}
r8NatIFIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT index"
::= { r8NatIFModeEntry 2 }
r8NatIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r8NatIFModeEntry 3 }
r8NatMode OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
nat(2),
napt(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT mode of interface"
::= { r8NatIFModeEntry 4 }
--
-- OCT-RT-B NAT IP Pool
--
r8NatIPPool OBJECT-TYPE
SYNTAX SEQUENCE OF R8NatIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP Pool Table"
::= { r8NAT 2 }
r8NatIPPoolEntry OBJECT-TYPE
SYNTAX R8NatIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP Pool Entry"
INDEX { r8Index ,
r8NatIFIndex ,
r8NatPoolIndex }
::= { r8NatIPPool 1 }
R8NatIPPoolEntry ::= SEQUENCE {
r8NatPoolIndex INTEGER,
r8NatPoolIFName DisplayString,
r8NatStartAddress DisplayString,
r8NatEndAddress DisplayString
}
r8NatPoolIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Pool index"
::= { r8NatIPPoolEntry 3 }
r8NatPoolIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanX pvc1-16)"
::= { r8NatIPPoolEntry 4 }
r8NatStartAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT start address"
::= { r8NatIPPoolEntry 5 }
r8NatEndAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT end address"
::= { r8NatIPPoolEntry 6 }
--
-- R8 NAT Add or Delete IP Pool
--
r8NatAddDelIPPool OBJECT-TYPE
SYNTAX SEQUENCE OF R8NatAddDelIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete NAT IP Pool Table"
::= { r8NAT 3 }
r8NatAddDelIPPoolEntry OBJECT-TYPE
SYNTAX R8NatAddDelIPPoolEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete NAT IP Pool Entry"
INDEX { r8Index }
::= { r8NatAddDelIPPool 1 }
R8NatAddDelIPPoolEntry ::= SEQUENCE {
r8NatAddDelPoolIFName DisplayString,
r8NatAddDelPoolIndex INTEGER,
r8NatAddDelStartAddr DisplayString,
r8NatAddDelEndAddr DisplayString,
r8NatAddDelIPPoolCMD INTEGER
}
r8NatAddDelPoolIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanx pvc1-16)"
::= { r8NatAddDelIPPoolEntry 2 }
r8NatAddDelPoolIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete IP Pool index"
::= { r8NatAddDelIPPoolEntry 3 }
r8NatAddDelStartAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT start address(xxx.xxx.xxx.xxx)"
::= { r8NatAddDelIPPoolEntry 4 }
r8NatAddDelEndAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT end address(xxx.xxx.xxx.xxx)"
::= { r8NatAddDelIPPoolEntry 5 }
r8NatAddDelIPPoolCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete IP Pool command"
::= { r8NatAddDelIPPoolEntry 6 }
--
-- OCT-RT-B NAT IP Static
--
r8NatIPStatic OBJECT-TYPE
SYNTAX SEQUENCE OF R8NatIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP static status Table"
::= { r8NAT 4 }
r8NatIPStaticEntry OBJECT-TYPE
SYNTAX R8NatIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT IP static status Entry"
INDEX { r8Index ,
r8NatIFIndex ,
r8NatIPStaticIndex }
::= { r8NatIPStatic 1 }
R8NatIPStaticEntry ::= SEQUENCE {
r8NatIPStaticIndex INTEGER,
r8NatIPStaticIFName DisplayString,
r8NatIPStaticPublicAddr DisplayString,
r8NatIPStaticPrivateAddr DisplayString
}
r8NatIPStaticIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static index"
::= { r8NatIPStaticEntry 2 }
r8NatIPStaticIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface name(wan1-64/wanx pvc1-16)"
::= { r8NatIPStaticEntry 3 }
r8NatIPStaticPublicAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static public Address"
::= { r8NatIPStaticEntry 4 }
r8NatIPStaticPrivateAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAT IP static private Address"
::= { r8NatIPStaticEntry 5 }
--
-- OCT-RT-B NAT Add or Delete IP Static
--
r8NatAddDelIPStatic OBJECT-TYPE
SYNTAX SEQUENCE OF R8NatAddDelIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static Table"
::= { r8NAT 5 }
r8NatAddDelIPStaticEntry OBJECT-TYPE
SYNTAX R8NatAddDelIPStaticEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static Entry"
INDEX { r8Index }
::= { r8NatAddDelIPStatic 1 }
R8NatAddDelIPStaticEntry ::= SEQUENCE {
r8NatAddDelIPStaticIFName DisplayString,
r8NatAddDelPublicAddr DisplayString,
r8NatAddDelPrivateAddr DisplayString,
r8NatAddDelIPStaticCMD INTEGER
}
r8NatAddDelIPStaticIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(wan1-64/wanx pvc1-16)"
::= { r8NatAddDelIPStaticEntry 2 }
r8NatAddDelPublicAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP static public Address(xxx.xxx.xxx.xxx)"
::= { r8NatAddDelIPStaticEntry 3 }
r8NatAddDelPrivateAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP static private Address(xxx.xxx.xxx.xxx)"
::= { r8NatAddDelIPStaticEntry 4 }
r8NatAddDelIPStaticCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT add or delete IP static command"
::= { r8NatAddDelIPStaticEntry 5 }
--
-- OCT-RT-B NAPT Port Forwarding
--
r8NaptPortForwarding OBJECT-TYPE
SYNTAX SEQUENCE OF R8NaptPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding Table"
::= { r8NAT 6 }
r8NaptPortForwardingEntry OBJECT-TYPE
SYNTAX R8NaptPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding Entry"
INDEX { r8Index ,
r8NaptIFIndex ,
r8NaptPortFwdIndex }
::= { r8NaptPortForwarding 1 }
R8NaptPortForwardingEntry ::= SEQUENCE {
r8NaptIFIndex INTEGER,
r8NaptPortFwdIndex INTEGER,
r8NaptIFName DisplayString,
r8NaptPortFwdName DisplayString,
r8NaptPortFwdStartPort INTEGER,
r8NaptPortFwdEndPort INTEGER,
r8NaptPortFwdServerIP DisplayString
}
r8NaptIFIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface index"
::= { r8NaptPortForwardingEntry 2 }
r8NaptPortFwdIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"NAPT Port Forwarding entry index"
::= { r8NaptPortForwardingEntry 3 }
r8NaptIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r8NaptPortForwardingEntry 4 }
r8NaptPortFwdName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NAPT entry name"
::= { r8NaptPortForwardingEntry 5 }
r8NaptPortFwdStartPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Start Port number"
::= { r8NaptPortForwardingEntry 6 }
r8NaptPortFwdEndPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"End Port number"
::= { r8NaptPortForwardingEntry 7 }
r8NaptPortFwdServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the service(xxx.xxx.xxx.xxx)"
::= { r8NaptPortForwardingEntry 8 }
--
-- OCT-RT-B NAPT Add or Delete Port Forwarding
--
r8NaptAddDelPortForwarding OBJECT-TYPE
SYNTAX SEQUENCE OF R8NaptAddDelPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Add or Delete Port Forwarding Table"
::= { r8NAT 7 }
r8NaptAddDelPortForwardingEntry OBJECT-TYPE
SYNTAX R8NaptAddDelPortForwardingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"NAPT Add or Delete Port Forwarding Entry"
INDEX { r8Index }
::= { r8NaptAddDelPortForwarding 1 }
R8NaptAddDelPortForwardingEntry ::= SEQUENCE {
r8NaptAddDelIFName DisplayString,
r8NaptAddDelName DisplayString,
r8NaptAddDelStartPort INTEGER,
r8NaptAddDelEndPort INTEGER,
r8NaptAddDelServerIP DisplayString,
r8NaptAddDelPortFwdCMD INTEGER
}
r8NaptAddDelIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r8NaptAddDelPortForwardingEntry 2 }
r8NaptAddDelName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NAPT entry name"
::= { r8NaptAddDelPortForwardingEntry 3 }
r8NaptAddDelStartPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Start Port number"
::= { r8NaptAddDelPortForwardingEntry 4 }
r8NaptAddDelEndPort OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"End Port number"
::= { r8NaptAddDelPortForwardingEntry 5 }
r8NaptAddDelServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the service(xxx.xxx.xxx.xxx)"
::= { r8NaptAddDelPortForwardingEntry 6 }
r8NaptAddDelPortFwdCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAPT add or delete port forwarding command"
::= { r8NaptAddDelPortForwardingEntry 7 }
--
-- OCT-RT-B VLAN
--
r8VLAN OBJECT IDENTIFIER ::= { oct-rt-b-card 8 }
--
-- R8 VLAN State
--
r8VlanState OBJECT-TYPE
SYNTAX SEQUENCE OF R8VlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Table"
::= { r8VLAN 1 }
r8VlanStateEntry OBJECT-TYPE
SYNTAX R8VlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Entry"
INDEX { r8Index ,
r8BrgGroupID }
::= { r8VlanState 1 }
R8VlanStateEntry ::= SEQUENCE {
r8VlanBrgName DisplayString,
r8VlanEnable INTEGER,
r8VlanMgmtVID INTEGER,
r8VlanRegenCRC INTEGER
}
r8VlanBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8VlanStateEntry 3 }
r8VlanEnable OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan state enable/disable"
::= { r8VlanStateEntry 4 }
r8VlanMgmtVID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN ID for the bridge management interface"
::= { r8VlanStateEntry 5 }
r8VlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable CRC regenerating on WAN interfaces for VLAN frames"
::= { r8VlanStateEntry 6 }
--
-- OCT-RT-B VLAN Table
--
r8VlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8VlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan Table"
::= { r8VLAN 2 }
r8VlanTableEntry OBJECT-TYPE
SYNTAX R8VlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan Table Tag Member Entry"
INDEX { r8Index ,
r8BrgGroupID ,
r8VlanID ,
r8VlanTableIndex }
::= { r8VlanTable 1 }
R8VlanTableEntry ::= SEQUENCE {
r8VlanID INTEGER,
r8VlanTableIndex INTEGER,
r8VlanTagMember DisplayString,
r8VlanUnTagMember DisplayString
}
r8VlanID OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan Index"
::= { r8VlanTableEntry 3 }
r8VlanTableIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan Tag Index"
::= { r8VlanTableEntry 4 }
r8VlanTagMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r8VlanTableEntry 5 }
r8VlanUnTagMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r8VlanTableEntry 6 }
--
-- OCT-RT-B VLAN Table Control
--
r8VlanTableControl OBJECT IDENTIFIER ::= { r8VLAN 3 }
--
-- R8 VLAN Create and Destroy VLAN
--
r8VlanCreateDestroyVlan OBJECT-TYPE
SYNTAX SEQUENCE OF R8VlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy vlan Table"
::= { r8VlanTableControl 1 }
r8VlanCreateDestroyVlanEntry OBJECT-TYPE
SYNTAX R8VlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy vlan Entry"
INDEX { r8Index }
::= { r8VlanCreateDestroyVlan 1 }
R8VlanCreateDestroyVlanEntry ::= SEQUENCE {
r8VlanCreateDestroyBrgName DisplayString,
r8VlanCreateDestroyVidNum INTEGER,
r8ValnCreateDestroyCMD INTEGER
}
r8VlanCreateDestroyBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8VlanCreateDestroyVlanEntry 2 }
r8VlanCreateDestroyVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan VID"
::= { r8VlanCreateDestroyVlanEntry 3 }
r8ValnCreateDestroyCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
create-vlan(1),
destroy-vlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create and destroy vlan command"
::= { r8VlanCreateDestroyVlanEntry 4 }
--
-- R8 VLAN Add and Delete Port
--
r8VlanAddDelPort OBJECT-TYPE
SYNTAX SEQUENCE OF R8VlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan add and del port Table"
::= { r8VlanTableControl 2 }
r8VlanAddDelPortEntry OBJECT-TYPE
SYNTAX R8VlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan add and del port Entry"
INDEX { r8Index }
::= { r8VlanAddDelPort 1 }
R8VlanAddDelPortEntry ::= SEQUENCE {
r8VlanAddDelPortBrgName DisplayString,
r8VlanAddDelPortVidNum INTEGER,
r8VlanAddDelPortTag INTEGER,
r8VlanAddDelPortInterface DisplayString,
r8VlanAddDelPortCMD INTEGER
}
r8VlanAddDelPortBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8VlanAddDelPortEntry 2 }
r8VlanAddDelPortVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan VID"
::= { r8VlanAddDelPortEntry 3 }
r8VlanAddDelPortTag OBJECT-TYPE
SYNTAX INTEGER{
untag(1),
tag(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan member mask"
::= { r8VlanAddDelPortEntry 4 }
r8VlanAddDelPortInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name (lan1~2/wan1~wan64/wanX pvc1-16)"
::= { r8VlanAddDelPortEntry 5 }
r8VlanAddDelPortCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add-port-to-vlan(1),
delete-port-from-vlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan add and delete port command"
::= { r8VlanAddDelPortEntry 6 }
--
-- OCT-RT-B VLAN Port Table
--
r8VlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8VlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Table"
::= { r8VLAN 4 }
r8VlanPortTableEntry OBJECT-TYPE
SYNTAX R8VlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Entry"
INDEX { r8Index ,
r8VlanPortIndex }
::= { r8VlanPortTable 1 }
R8VlanPortTableEntry ::= SEQUENCE {
r8VlanPortIndex INTEGER,
r8VlanPortIFName DisplayString,
r8VlanPortPVID INTEGER,
r8VlanPortFrameType INTEGER,
r8VlanPortIngressFilter INTEGER
}
r8VlanPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan port index"
::= { r8VlanPortTableEntry 2 }
r8VlanPortIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port type(lan1~2/wan1~wan64/wanX pvc1-16)"
::= { r8VlanPortTableEntry 3 }
r8VlanPortPVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface PVID"
::= { r8VlanPortTableEntry 4 }
r8VlanPortFrameType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
all(1),
tag-only(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the acceptable frame type"
::= { r8VlanPortTableEntry 5 }
r8VlanPortIngressFilter OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable ingress filtering"
::= { r8VlanPortTableEntry 6 }
--Jass
--
-- OCT-RT-B DHCP
--
r8DHCP OBJECT IDENTIFIER ::= { oct-rt-b-card 9 }
--
-- R8 DHCP Server
--
r8DHCPServer OBJECT IDENTIFIER ::= { r8DHCP 1 }
--
-- R8 DHCP Server Config
--
r8DhcpServerCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpServerCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Server Config Table"
::= { r8DHCPServer 1 }
r8DhcpServerCFGEntry OBJECT-TYPE
SYNTAX R8DhcpServerCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Server Config Entry"
INDEX { r8Index }
::= { r8DhcpServerCFG 1 }
R8DhcpServerCFGEntry ::= SEQUENCE {
r8DhcpServer INTEGER,
r8DhcpServerInterface DisplayString,
r8DhcpServerBridgeMgmt DisplayString
}
r8DhcpServer OBJECT-TYPE
SYNTAX INTEGER{
na(0),
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP function disable/enable"
::= { r8DhcpServerCFGEntry 2 }
r8DhcpServerInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP interface config"
::= { r8DhcpServerCFGEntry 3 }
r8DhcpServerBridgeMgmt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP bridge mgmt"
::= { r8DhcpServerCFGEntry 4 }
--
-- R8 Add or Delete DHCP Server Interface
--
r8DhcpServerAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpServerAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP interface Table"
::= { r8DHCPServer 2 }
r8DhcpServerAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R8DhcpServerAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP interface Entry"
INDEX { r8Index }
::= { r8DhcpServerAddDelInterface 1 }
R8DhcpServerAddDelInterfaceEntry ::= SEQUENCE {
r8DhcpServerAddDelIntfName DisplayString,
r8DhcpServerAddDelIntfCMD INTEGER
}
r8DhcpServerAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name(lan1/lan2/bridge group name)"
::= { r8DhcpServerAddDelInterfaceEntry 2 }
r8DhcpServerAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete interface command"
::= { r8DhcpServerAddDelInterfaceEntry 3 }
--
-- R8 DHCP Server Host Table
--
r8DHCPHost OBJECT IDENTIFIER ::= { r8DHCPServer 3 }
--
-- R8 DHCP Server Host Config Table
--
r8DhcpHostCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpHostCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host config Table"
::= { r8DHCPHost 1 }
r8DhcpHostCFGEntry OBJECT-TYPE
SYNTAX R8DhcpHostCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host config Entry"
INDEX { r8Index ,
r8DhcpHostIndex }
::= { r8DhcpHostCFG 1 }
R8DhcpHostCFGEntry ::= SEQUENCE {
r8DhcpHostIndex INTEGER,
r8DhcpHostName DisplayString,
r8DhcpHostHWType INTEGER,
r8DhcpHostHWAddr DisplayString,
r8DhcpHostFixedAddr DisplayString,
r8DhcpHostBootStrapFile DisplayString,
r8DhcpHostNextServer DisplayString,
r8DhcpHostClientIdentifier DisplayString,
r8DhcpHostDefLeaseTime INTEGER
}
r8DhcpHostIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host configuration index"
::= { r8DhcpHostCFGEntry 2 }
r8DhcpHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host configuration name"
::= { r8DhcpHostCFGEntry 3 }
r8DhcpHostHWType OBJECT-TYPE
SYNTAX INTEGER{
null(0),
ethernet(1),
token-ring(2),
fddi(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host hardware type"
::= { r8DhcpHostCFGEntry 4 }
r8DhcpHostHWAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host hardware address"
::= { r8DhcpHostCFGEntry 5 }
r8DhcpHostFixedAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host address"
::= { r8DhcpHostCFGEntry 6 }
r8DhcpHostBootStrapFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host bootstrap file"
::= { r8DhcpHostCFGEntry 7 }
r8DhcpHostNextServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP next server in boot process"
::= { r8DhcpHostCFGEntry 8 }
r8DhcpHostClientIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..9))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host client identifier"
::= { r8DhcpHostCFGEntry 9 }
r8DhcpHostDefLeaseTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host default duration of the lease"
::= { r8DhcpHostCFGEntry 10 }
--
-- R8 Add or Delete DHCP Server Host
--
r8AddDelDhcpHost OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelDhcpHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host control Table"
::= { r8DHCPHost 2 }
r8AddDelDhcpHostEntry OBJECT-TYPE
SYNTAX R8AddDelDhcpHostEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host control Entry"
INDEX { r8Index }
::= { r8AddDelDhcpHost 1 }
R8AddDelDhcpHostEntry ::= SEQUENCE {
r8AddDelDhcpHostName DisplayString,
r8DhcpHostCMD INTEGER
}
r8AddDelDhcpHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host configuration name"
::= { r8AddDelDhcpHostEntry 2 }
r8DhcpHostCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP host configuration"
::= { r8AddDelDhcpHostEntry 3 }
--
-- R8 DHCP Host Option
--
r8DhcpHostOption OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option Table"
::= { r8DHCPHost 3 }
r8DhcpHostOptionEntry OBJECT-TYPE
SYNTAX R8DhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option Entry"
INDEX { r8Index ,
r8DhcpHostIndex ,
r8DhcpHostOptionIndex }
::= { r8DhcpHostOption 1 }
R8DhcpHostOptionEntry ::= SEQUENCE {
r8DhcpHostOptionIndex INTEGER,
r8DhcpHostOptionHostName DisplayString,
r8DhcpHostOptionCode INTEGER,
r8DhcpHostOptionValue DisplayString
}
r8DhcpHostOptionIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host Option index"
::= { r8DhcpHostOptionEntry 3 }
r8DhcpHostOptionHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host name"
::= { r8DhcpHostOptionEntry 4 }
r8DhcpHostOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host option code"
::= { r8DhcpHostOptionEntry 5 }
r8DhcpHostOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP host option value"
::= { r8DhcpHostOptionEntry 6 }
--
-- R8 Add or Delete DHCP Host Option
--
r8AddDelDhcpHostOption OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelDhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option control Table"
::= { r8DHCPHost 4 }
r8AddDelDhcpHostOptionEntry OBJECT-TYPE
SYNTAX R8AddDelDhcpHostOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP host option control Entry"
INDEX { r8Index }
::= { r8AddDelDhcpHostOption 1 }
R8AddDelDhcpHostOptionEntry ::= SEQUENCE {
r8AddDelHostOptionHostName DisplayString,
r8AddDelHostOptionCode INTEGER,
r8AddDelHostOptionValue DisplayString,
r8AddDelHostOptionCMD INTEGER
}
r8AddDelHostOptionHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host name"
::= { r8AddDelDhcpHostOptionEntry 2 }
r8AddDelHostOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host option code"
::= { r8AddDelDhcpHostOptionEntry 3 }
r8AddDelHostOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP host option value"
::= { r8AddDelDhcpHostOptionEntry 4 }
r8AddDelHostOptionCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete DHCP host option command"
::= { r8AddDelDhcpHostOptionEntry 5 }
--
-- R8 DHCP Server Subnet Table
--
r8DHCPSubnet OBJECT IDENTIFIER ::= { r8DHCPServer 4 }
--
-- R8 DHCP Server Subnet Config-1 Table
--
r8DhcpSubnetCFG1 OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpSubnetCFG1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Table"
::= { r8DHCPSubnet 1 }
r8DhcpSubnetCFG1Entry OBJECT-TYPE
SYNTAX R8DhcpSubnetCFG1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Entry"
INDEX { r8Index ,
r8DhcpSubnetIndex }
::= { r8DhcpSubnetCFG1 1 }
R8DhcpSubnetCFG1Entry ::= SEQUENCE {
r8DhcpSubnetIndex INTEGER,
r8DhcpCfg1SubnetName DisplayString,
r8DhcpSubnetNetworkAddr DisplayString,
r8DhcpSubnetStartAddr DisplayString,
r8DhcpSubnetEndAddr DisplayString,
r8DhcpSubnetBootp INTEGER,
r8DhcpSubnetDefLeaseTime INTEGER,
r8DhcpSubnetBootStrapFile DisplayString,
r8DhcpSubnetNextServer DisplayString
}
r8DhcpSubnetIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet index"
::= { r8DhcpSubnetCFG1Entry 2 }
r8DhcpCfg1SubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8DhcpSubnetCFG1Entry 3 }
r8DhcpSubnetNetworkAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet address/netmask(xxx.xxx.xxx.xxx/xx)"
::= { r8DhcpSubnetCFG1Entry 4 }
r8DhcpSubnetStartAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet ip range(start)"
::= { r8DhcpSubnetCFG1Entry 5 }
r8DhcpSubnetEndAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet ip range(end)"
::= { r8DhcpSubnetCFG1Entry 6 }
r8DhcpSubnetBootp OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet bootp support"
::= { r8DhcpSubnetCFG1Entry 7 }
r8DhcpSubnetDefLeaseTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet default duration of the lease"
::= { r8DhcpSubnetCFG1Entry 8 }
r8DhcpSubnetBootStrapFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet bootstrap file"
::= { r8DhcpSubnetCFG1Entry 9 }
r8DhcpSubnetNextServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet next server in boot process"
::= { r8DhcpSubnetCFG1Entry 10 }
--
-- R8 DHCP Server Subnet Config-2 Table
--
r8DhcpSubnetCFG2 OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpSubnetCFG2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Table"
::= { r8DHCPSubnet 2 }
r8DhcpSubnetCFG2Entry OBJECT-TYPE
SYNTAX R8DhcpSubnetCFG2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet config Entry"
INDEX { r8Index ,
r8DhcpSubnetIndex }
::= { r8DhcpSubnetCFG2 1 }
R8DhcpSubnetCFG2Entry ::= SEQUENCE {
r8DhcpCfg2SubnetName DisplayString,
r8DhcpSubnetDomainName DisplayString,
r8DhcpSubnetDNSServer1 DisplayString,
r8DhcpSubnetDNSServer2 DisplayString,
r8DhcpSubnetDNSServer3 DisplayString,
r8DhcpSubnetDNSServer4 DisplayString,
r8DhcpSubnetDefRouter1 DisplayString,
r8DhcpSubnetDefRouter2 DisplayString,
r8DhcpSubnetDefRouter3 DisplayString,
r8DhcpSubnetDefRouter4 DisplayString,
r8DhcpSubnetNetbiosServer1 DisplayString,
r8DhcpSubnetNetbiosServer2 DisplayString,
r8DhcpSubnetNetbiosServer3 DisplayString,
r8DhcpSubnetNetbiosServer4 DisplayString,
r8DhcpSubnetNetbiosNode INTEGER
}
r8DhcpCfg2SubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8DhcpSubnetCFG2Entry 3 }
r8DhcpSubnetDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name"
::= { r8DhcpSubnetCFG2Entry 4 }
r8DhcpSubnetDNSServer1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 1"
::= { r8DhcpSubnetCFG2Entry 5 }
r8DhcpSubnetDNSServer2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 2"
::= { r8DhcpSubnetCFG2Entry 6 }
r8DhcpSubnetDNSServer3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 3"
::= { r8DhcpSubnetCFG2Entry 7 }
r8DhcpSubnetDNSServer4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name server 4"
::= { r8DhcpSubnetCFG2Entry 8 }
r8DhcpSubnetDefRouter1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 1"
::= { r8DhcpSubnetCFG2Entry 9 }
r8DhcpSubnetDefRouter2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 2"
::= { r8DhcpSubnetCFG2Entry 10 }
r8DhcpSubnetDefRouter3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 3"
::= { r8DhcpSubnetCFG2Entry 11 }
r8DhcpSubnetDefRouter4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet default router 4"
::= { r8DhcpSubnetCFG2Entry 12 }
r8DhcpSubnetNetbiosServer1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 1"
::= { r8DhcpSubnetCFG2Entry 13 }
r8DhcpSubnetNetbiosServer2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 2"
::= { r8DhcpSubnetCFG2Entry 14 }
r8DhcpSubnetNetbiosServer3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 3"
::= { r8DhcpSubnetCFG2Entry 15 }
r8DhcpSubnetNetbiosServer4 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet NBNS name server 4"
::= { r8DhcpSubnetCFG2Entry 16 }
r8DhcpSubnetNetbiosNode OBJECT-TYPE
SYNTAX INTEGER{
null(0),
b-node(1),
p-node(2),
m-node(4),
h-node(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios node type"
::= { r8DhcpSubnetCFG2Entry 17 }
--
-- R8 Add or Delete DHCP Subnet
--
r8AddDelDhcpSubnet OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelDhcpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet control Table"
::= { r8DHCPSubnet 3 }
r8AddDelDhcpSubnetEntry OBJECT-TYPE
SYNTAX R8AddDelDhcpSubnetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet control Entry"
INDEX { r8Index }
::= { r8AddDelDhcpSubnet 1 }
R8AddDelDhcpSubnetEntry ::= SEQUENCE {
r8AddDelDhcpSubnetName DisplayString,
r8DhcpSubnetCMD INTEGER
}
r8AddDelDhcpSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet domain name"
::= { r8AddDelDhcpSubnetEntry 2 }
r8DhcpSubnetCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet configuration"
::= { r8AddDelDhcpSubnetEntry 3 }
--
-- R8 Add or Delete DHCP Subnet DNS Server
--
r8AddDelSubnetDNSServer OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelSubnetDNSServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server control Table"
::= { r8DHCPSubnet 4 }
r8AddDelSubnetDNSServerEntry OBJECT-TYPE
SYNTAX R8AddDelSubnetDNSServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server control Entry"
INDEX { r8Index }
::= { r8AddDelSubnetDNSServer 1 }
R8AddDelSubnetDNSServerEntry ::= SEQUENCE {
r8AddDelDNSServerSubnetName DisplayString,
r8AddDelDNSServerAddr DisplayString,
r8AddDelDNSSeverCMD INTEGER
}
r8AddDelDNSServerSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8AddDelSubnetDNSServerEntry 2 }
r8AddDelDNSServerAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet DNS Server Address"
::= { r8AddDelSubnetDNSServerEntry 3 }
r8AddDelDNSSeverCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet DNS Server"
::= { r8AddDelSubnetDNSServerEntry 4 }
--
-- R8 Add or Delete DHCP Subnet Default Routers
--
r8AddDelSubnetDefRouter OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelSubnetDefRouterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet default router control Table"
::= { r8DHCPSubnet 5 }
r8AddDelSubnetDefRouterEntry OBJECT-TYPE
SYNTAX R8AddDelSubnetDefRouterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet default router control Entry"
INDEX { r8Index }
::= { r8AddDelSubnetDefRouter 1 }
R8AddDelSubnetDefRouterEntry ::= SEQUENCE {
r8AddDelDefRTRSubnetName DisplayString,
r8AddDelDefRouterAddr DisplayString,
r8AddDelDefRouterCMD INTEGER
}
r8AddDelDefRTRSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8AddDelSubnetDefRouterEntry 2 }
r8AddDelDefRouterAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet default router address"
::= { r8AddDelSubnetDefRouterEntry 3 }
r8AddDelDefRouterCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet default router"
::= { r8AddDelSubnetDefRouterEntry 4 }
--
-- R8 Add or Delete DHCP Subnet Netbios Server
--
r8AddDelSubnetNetbiosServer OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelSubnetNetbiosServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server control Table"
::= { r8DHCPSubnet 6 }
r8AddDelSubnetNetbiosServerEntry OBJECT-TYPE
SYNTAX R8AddDelSubnetNetbiosServerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server control Entry"
INDEX { r8Index }
::= { r8AddDelSubnetNetbiosServer 1 }
R8AddDelSubnetNetbiosServerEntry ::= SEQUENCE {
r8AddDelNetbSubnetName DisplayString,
r8AddDelNetbServerAddr DisplayString,
r8AddDelNetbServerCMD INTEGER
}
r8AddDelNetbSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8AddDelSubnetNetbiosServerEntry 2 }
r8AddDelNetbServerAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet netbios server address"
::= { r8AddDelSubnetNetbiosServerEntry 3 }
r8AddDelNetbServerCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete a DHCP subnet netbios server"
::= { r8AddDelSubnetNetbiosServerEntry 4 }
--
-- R8 DHCP Subnet Option
--
r8DhcpSubnetOption OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option Table"
::= { r8DHCPSubnet 7 }
r8DhcpSubnetOptionEntry OBJECT-TYPE
SYNTAX R8DhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option Entry"
INDEX { r8Index ,
r8DhcpSubnetIndex ,
r8DhcpSubnetOptionIndex }
::= { r8DhcpSubnetOption 1 }
R8DhcpSubnetOptionEntry ::= SEQUENCE {
r8DhcpSubnetOptionIndex INTEGER,
r8DhcpSubnetOptSubnetName DisplayString,
r8DhcpSubnetOptionCode INTEGER,
r8DhcpSubnetOptionValue DisplayString
}
r8DhcpSubnetOptionIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet Option index"
::= { r8DhcpSubnetOptionEntry 3 }
r8DhcpSubnetOptSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8DhcpSubnetOptionEntry 4 }
r8DhcpSubnetOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet option code"
::= { r8DhcpSubnetOptionEntry 5 }
r8DhcpSubnetOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP subnet option value"
::= { r8DhcpSubnetOptionEntry 6 }
--
-- R8 Add or Delete DHCP Subnet Option
--
r8AddDelDhcpSubnetOption OBJECT-TYPE
SYNTAX SEQUENCE OF R8AddDelDhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option control Table"
::= { r8DHCPSubnet 8 }
r8AddDelDhcpSubnetOptionEntry OBJECT-TYPE
SYNTAX R8AddDelDhcpSubnetOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP subnet option control Entry"
INDEX { r8Index }
::= { r8AddDelDhcpSubnetOption 1 }
R8AddDelDhcpSubnetOptionEntry ::= SEQUENCE {
r8AddDelSubnetOptSubnetName DisplayString,
r8AddDelSubnetOptionCode INTEGER,
r8AddDelSubnetOptionValue DisplayString,
r8AddDelSubnetOptionCMD INTEGER
}
r8AddDelSubnetOptSubnetName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet name"
::= { r8AddDelDhcpSubnetOptionEntry 2 }
r8AddDelSubnetOptionCode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet option code"
::= { r8AddDelDhcpSubnetOptionEntry 3 }
r8AddDelSubnetOptionValue OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP subnet option value"
::= { r8AddDelDhcpSubnetOptionEntry 4 }
r8AddDelSubnetOptionCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete DHCP subnet option"
::= { r8AddDelDhcpSubnetOptionEntry 5 }
--
-- R8 DHCP Relay
--
r8DHCPRelay OBJECT IDENTIFIER ::= { r8DHCP 2 }
--
-- R8 DHCP Relay Config
--
r8DhcpRelayCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpRelayCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Relay Config Table"
::= { r8DHCPRelay 1 }
r8DhcpRelayCFGEntry OBJECT-TYPE
SYNTAX R8DhcpRelayCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DHCP Relay Config Entry"
INDEX { r8Index }
::= { r8DhcpRelayCFG 1 }
R8DhcpRelayCFGEntry ::= SEQUENCE {
r8DhcpRelay INTEGER,
r8DhcpRelayServerIP DisplayString,
r8DhcpRelayInterface DisplayString,
r8DhcpRelayBridgeMgmt DisplayString
}
r8DhcpRelay OBJECT-TYPE
SYNTAX INTEGER{
na(0),
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP relay function disable/enable"
::= { r8DhcpRelayCFGEntry 2 }
r8DhcpRelayServerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DHCP Relay Server IP"
::= { r8DhcpRelayCFGEntry 3 }
r8DhcpRelayInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP relay interface"
::= { r8DhcpRelayCFGEntry 4 }
r8DhcpRelayBridgeMgmt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DHCP relay bridge mgmt"
::= { r8DhcpRelayCFGEntry 5 }
--
-- R8 Add or Delete DHCP Relay Interface
--
r8DhcpRelayAddDelInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R8DhcpRelayAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP Relay interface Table"
::= { r8DHCPRelay 2 }
r8DhcpRelayAddDelInterfaceEntry OBJECT-TYPE
SYNTAX R8DhcpRelayAddDelInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add or Delete DHCP Relay interface Entry"
INDEX { r8Index }
::= { r8DhcpRelayAddDelInterface 1 }
R8DhcpRelayAddDelInterfaceEntry ::= SEQUENCE {
r8DhcpRelayAddDelIntfName DisplayString,
r8DhcpRelayAddDelIntfCMD INTEGER
}
r8DhcpRelayAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r8DhcpRelayAddDelInterfaceEntry 2 }
r8DhcpRelayAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add or delete interface command"
::= { r8DhcpRelayAddDelInterfaceEntry 3 }
--
-- R8 MultiLink
--
r8MultiLink OBJECT IDENTIFIER ::= { oct-rt-b-card 10 }
--
-- R8 MultiLink Config Table
--
r8MultiLinkCFG OBJECT-TYPE
SYNTAX SEQUENCE OF R8MultiLinkCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MultiLink Config Table."
::= { r8MultiLink 1 }
r8MultiLinkCFGEntry OBJECT-TYPE
SYNTAX R8MultiLinkCFGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MultiLink Config Entry"
INDEX { r8Index ,
r8MLinkIndex }
::= { r8MultiLinkCFG 1 }
R8MultiLinkCFGEntry ::= SEQUENCE {
r8MLinkIndex INTEGER,
r8MLinkName DisplayString,
r8MLinkIPAddr DisplayString,
r8MLinkBundles DisplayString,
r8MLinkInterval INTEGER,
r8MLinkTimes INTEGER
}
r8MLinkIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Index"
::= { r8MultiLinkCFGEntry 2 }
r8MLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Virtual Name"
::= { r8MultiLinkCFGEntry 3 }
r8MLinkIPAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink IP Address(xxx.xxx.xxx.xxx/xx)"
::= { r8MultiLinkCFGEntry 4 }
r8MLinkBundles OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Multilink Boundles Interface"
::= { r8MultiLinkCFGEntry 5 }
r8MLinkInterval OBJECT-TYPE
SYNTAX INTEGER (5..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink The Retry Interval"
::= { r8MultiLinkCFGEntry 6 }
r8MLinkTimes OBJECT-TYPE
SYNTAX INTEGER (6..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Multilink The Retry Times"
::= { r8MultiLinkCFGEntry 7 }
--
-- R8 Create and Destroy Multilink
--
r8CreateDestroyMultiLink OBJECT-TYPE
SYNTAX SEQUENCE OF R8CreateDestroyMultiLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy MultiLink Table."
::= { r8MultiLink 2 }
r8CreateDestroyMultiLinkEntry OBJECT-TYPE
SYNTAX R8CreateDestroyMultiLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and Destroy Multilin Entry"
INDEX { r8Index }
::= { r8CreateDestroyMultiLink 1 }
R8CreateDestroyMultiLinkEntry ::= SEQUENCE {
r8CreateDestroyMLinkName DisplayString,
r8CreateDestroyMLinkCMD INTEGER
}
r8CreateDestroyMLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Destroy Multilink Name"
::= { r8CreateDestroyMultiLinkEntry 2 }
r8CreateDestroyMLinkCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
create(1),
destroy(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Destory Multilink Command"
::= { r8CreateDestroyMultiLinkEntry 3 }
--
-- R8 MultiLink Add/Delete Interface Table
--
r8MultiLinkAddDeleteInterface OBJECT-TYPE
SYNTAX SEQUENCE OF R8MultiLinkAddDeleteInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add/Delete Interfaces To Multilink Bundle Table"
::= { r8MultiLink 3 }
r8MultiLinkAddDeleteInterfaceEntry OBJECT-TYPE
SYNTAX R8MultiLinkAddDeleteInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add/Delete Interfaces To Multilink Bundle Entry"
INDEX { r8Index }
::= { r8MultiLinkAddDeleteInterface 1 }
R8MultiLinkAddDeleteInterfaceEntry ::= SEQUENCE {
r8MLinkAddDelMLinkName DisplayString,
r8MLinkAddDelIntfName DisplayString,
r8MLinkAddDelIntfCMD INTEGER
}
r8MLinkAddDelMLinkName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete Interface MultiLink Name"
::= { r8MultiLinkAddDeleteInterfaceEntry 2 }
r8MLinkAddDelIntfName OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete Interfaces(wan1~wan64) to Multilink Bundle"
::= { r8MultiLinkAddDeleteInterfaceEntry 3 }
r8MLinkAddDelIntfCMD OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
add(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add/Delete interfaces To/From Multilink Bundle"
::= { r8MultiLinkAddDeleteInterfaceEntry 4 }
--==================================================
-- R8SVLAN
--==================================================
r8svlan OBJECT IDENTIFIER ::= { oct-rt-b-card 11 }
--==================================================
-- R8SVLAN State
--==================================================
r8svlanState OBJECT-TYPE
SYNTAX SEQUENCE OF R8SvlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan state Table"
::= { r8svlan 1 }
r8svlanStateEntry OBJECT-TYPE
SYNTAX R8SvlanStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Svlan state Entry"
INDEX { r8ssIndex , r8svlanBrgGroupID }
::= { r8svlanState 1 }
R8SvlanStateEntry ::= SEQUENCE {
r8ssIndex LargeSlotIndex,
r8svlanBrgGroupID INTEGER,
r8svlanBrgName DisplayString,
r8svlanEnable INTEGER,
r8svlanMgmtSVID INTEGER,
r8svlanRegenCRC INTEGER,
r8svlanTPID DisplayString,
r8svlanPCP INTEGER,
r8svlanDEI INTEGER
}
r8ssIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8svlanStateEntry 1 }
r8svlanBrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group ID"
::= { r8svlanStateEntry 2 }
r8svlanBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8svlanStateEntry 3 }
r8svlanEnable OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan state enable/disable"
::= { r8svlanStateEntry 4 }
r8svlanMgmtSVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVLAN ID for the bridge management interface"
::= { r8svlanStateEntry 5 }
r8svlanRegenCRC OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable CRC regenerating on WAN interfaces for SVLAN frames"
::= { r8svlanStateEntry 6 }
r8svlanTPID OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TPID "
::= { r8svlanStateEntry 7 }
r8svlanPCP OBJECT-TYPE
SYNTAX INTEGER(0..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Priority Code Point"
::= { r8svlanStateEntry 8 }
r8svlanDEI OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Drop Eligible Indicato"
::= { r8svlanStateEntry 9 }
--==================================================
-- R8SVLAN Table
--==================================================
r8svlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8SvlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan Table"
::= { r8svlan 2 }
r8svlanTableEntry OBJECT-TYPE
SYNTAX R8SvlanTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Svlan Table Tag Member Entry"
INDEX { r8stIndex ,
r8svlanTableBrgGroupID ,
r8svlanID ,
r8svlanTableIndex
}
::= { r8svlanTable 1 }
R8SvlanTableEntry ::= SEQUENCE {
r8stIndex LargeSlotIndex,
r8svlanTableBrgGroupID INTEGER,
r8svlanID INTEGER,
r8svlanTableIndex INTEGER,
r8svlanMember DisplayString
}
r8stIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8svlanTableEntry 1 }
r8svlanTableBrgGroupID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bridge Group Index"
::= { r8svlanTableEntry 2 }
r8svlanID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { r8svlanTableEntry 3 }
r8svlanTableIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Member Index"
::= { r8svlanTableEntry 4 }
r8svlanMember OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..200))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan member"
::= { r8svlanTableEntry 5 }
--=========================================================
-- SVLAN Table Control
--=========================================================
r8svlanTableControl OBJECT IDENTIFIER ::= { r8svlan 3 }
--=========================================================
-- SVLAN Create and Destroy
--=========================================================
r8svlanCreateDestroyVlan OBJECT-TYPE
SYNTAX SEQUENCE OF R8SvlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy svlan Table"
::= { r8svlanTableControl 1 }
r8svlanCreateDestroyVlanEntry OBJECT-TYPE
SYNTAX R8SvlanCreateDestroyVlanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Create and destroy svlan Entry"
INDEX { r8scIndex }
::= { r8svlanCreateDestroyVlan 1 }
R8SvlanCreateDestroyVlanEntry ::= SEQUENCE {
r8scIndex LargeSlotIndex,
r8svlanCreateDestroyBrgName DisplayString,
r8svlanCreateDestroyVidNum INTEGER,
r8svlanCreateDestroyCMD INTEGER
}
r8scIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8svlanCreateDestroyVlanEntry 1 }
r8svlanCreateDestroyBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8svlanCreateDestroyVlanEntry 2 }
r8svlanCreateDestroyVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Vlan VID"
::= { r8svlanCreateDestroyVlanEntry 3 }
r8svlanCreateDestroyCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
create-svlan(1),
destroy-svlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create and destroy vlan command"
::= { r8svlanCreateDestroyVlanEntry 4 }
--=========================================================
-- SVLAN Add and Delete Port
--=========================================================
r8svlanAddDelPort OBJECT-TYPE
SYNTAX SEQUENCE OF R8SvlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan add and del port Table"
::= { r8svlanTableControl 2 }
r8svlanAddDelPortEntry OBJECT-TYPE
SYNTAX R8SvlanAddDelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SVlan add and del port Entry"
INDEX { r8saIndex }
::= { r8svlanAddDelPort 1 }
R8SvlanAddDelPortEntry ::= SEQUENCE {
r8saIndex LargeSlotIndex,
r8svlanAddDelPortBrgName DisplayString,
r8svlanAddDelPortVidNum INTEGER,
r8svlanAddDelPortInterface DisplayString,
r8svlanAddDelPortCMD INTEGER
}
r8saIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8svlanAddDelPortEntry 1 }
r8svlanAddDelPortBrgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bridge group name"
::= { r8svlanAddDelPortEntry 2 }
r8svlanAddDelPortVidNum OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan VID"
::= { r8svlanAddDelPortEntry 3 }
r8svlanAddDelPortInterface OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface Name"
::= { r8svlanAddDelPortEntry 4 }
r8svlanAddDelPortCMD OBJECT-TYPE
SYNTAX INTEGER{
no(0), --//RIKER2021 SilverCreek
add-port-to-svlan(1),
delete-port-from-svlan(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SVlan add and delete port command"
::= { r8svlanAddDelPortEntry 5 }
--=========================================================
-- SVLAN Port Table
--=========================================================
r8svlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF R8SvlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Table"
::= { r8svlan 4 }
r8svlanPortTableEntry OBJECT-TYPE
SYNTAX R8SvlanPortTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan port table control Entry"
INDEX { r8spIndex , r8svlanPortIndex }
::= { r8svlanPortTable 1 }
R8SvlanPortTableEntry ::= SEQUENCE {
r8spIndex LargeSlotIndex,
r8svlanPortIndex INTEGER,
r8svlanPortIFName DisplayString,
r8svlanPortPVID INTEGER,
r8svlanPortType INTEGER,
r8svlanPortIngressFilter INTEGER
}
r8spIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { r8svlanPortTableEntry 1 }
r8svlanPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan port index"
::= { r8svlanPortTableEntry 2 }
r8svlanPortIFName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface name"
::= { r8svlanPortTableEntry 3 }
r8svlanPortPVID OBJECT-TYPE
SYNTAX INTEGER (0..4094) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface PVID"
::= { r8svlanPortTableEntry 4 }
r8svlanPortType OBJECT-TYPE
SYNTAX INTEGER{
na(0), --//RIKER2021 SilverCreek
provider(1),
customer(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"the acceptable port type"
::= { r8svlanPortTableEntry 5 }
r8svlanPortIngressFilter OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable ingress filtering"
::= { r8svlanPortTableEntry 6 }
r8TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of RTB"
::= { oct-rt-b-card 100 }
--======================================================================--
-- ts_card MIB
--
-- The NI table
--
tsNiControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS NI Configuration Control Table"
::= { ts-card 1 }
tsNiControlEntry OBJECT-TYPE
SYNTAX TsNiControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS NI configuration control entry"
INDEX { tsPortIndex ,
tsNetIndex }
::= { tsNiControlTable 1 }
TsNiControlEntry ::= SEQUENCE {
tsPortIndex SmallSlotIndex,
tsNetIndex INTEGER,
tsIPAddr IpAddress,
tsSubnetMask IpAddress,
tsFrame INTEGER,
tsRIP1 INTEGER,
tsRIP2 INTEGER,
tsMode INTEGER
}
tsPortIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { tsNiControlEntry 1 }
tsNetIndex OBJECT-TYPE
SYNTAX INTEGER {
dte1(1),
dte2(2),
dte3(3),
wan1(4),
wan2(5),
wan3(6),
wan4(7),
wan5(8),
wan6(9),
wan7(10),
wan8(11),
wan9(12),
wan10(13),
wan11(14),
wan12(15),
wan13(16),
wan14(17),
wan15(18),
wan16(19),
wan17(20),
wan18(21),
wan19(22),
wan20(23),
wan21(24),
wan22(25),
wan23(26),
wan24(27),
wan25(28),
wan26(29),
wan27(30),
wan28(31),
wan29(32),
wan30(33),
wan31(34),
wan32(35)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS Ni index"
::= { tsNiControlEntry 2}
tsIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS IP Address"
::= { tsNiControlEntry 3}
tsSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS net mask"
::= { tsNiControlEntry 4}
tsFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2),
-- fr(3),
slip-async(5),
raw-async(6),
ppp-sync(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS Layer2 frame"
::= { tsNiControlEntry 5}
tsRIP1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS RIP1"
::= { tsNiControlEntry 6}
tsRIP2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS RIP2"
::= { tsNiControlEntry 7}
tsMode OBJECT-TYPE
SYNTAX INTEGER {
route(1),
bridge(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS mode"
::= { tsNiControlEntry 8}
--
-- The DTE table
--
tsDteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsDteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS DTE Configuration Control Table"
::= { ts-card 2 }
tsDteControlEntry OBJECT-TYPE
SYNTAX TsDteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS DTE configuration control entry"
INDEX { tsPortIndex ,
tsDTEindex }
::= { tsDteControlTable 1 }
TsDteControlEntry ::= SEQUENCE {
tsDTEindex INTEGER,
tsDTEFrame INTEGER,
tsSpeed INTEGER,
tsDataBits INTEGER,
tsStopBits INTEGER,
tsParity INTEGER,
tsDestIPAddr IpAddress,
tsDestIPAddr2 IpAddress,
tsDestIPAddr3 IpAddress,
tsDestIPAddr4 IpAddress,
tsDestIPAddr5 IpAddress,
tsDTEMode INTEGER
}
tsDTEindex OBJECT-TYPE
SYNTAX INTEGER {
dte1(1),
dte2(2),
dte3(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS Dte index"
::= { tsDteControlEntry 1}
tsDTEFrame OBJECT-TYPE
SYNTAX INTEGER {
-- hdlc(1),
-- ppp(2),
-- fr(3),
slip-async(5),
raw-async(6),
ppp-sync(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Layer2 frame"
::= { tsDteControlEntry 2}
tsSpeed OBJECT-TYPE
SYNTAX INTEGER {
rate-38400(1),
rate-19200(2),
rate-9600(3),
rate-4800(4),
rate-2400(5),
rate-1200(6),
rate-64K(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Baud Rate"
::= { tsDteControlEntry 3}
tsDataBits OBJECT-TYPE
SYNTAX INTEGER {
data-8-bits(1),
data-7-bits(2),
null(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Data bits"
::= { tsDteControlEntry 4}
tsStopBits OBJECT-TYPE
SYNTAX INTEGER {
stop-1-bit(1),
stop-2-bits(2),
null(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Stop bits"
::= { tsDteControlEntry 5}
tsParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
even(2),
odd(3),
null(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Parity check "
::= { tsDteControlEntry 6}
tsDestIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS 1st IP Address"
::= { tsDteControlEntry 7}
tsDestIPAddr2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS 2nd IP Address"
::= { tsDteControlEntry 8}
tsDestIPAddr3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS 3rd IP Address"
::= { tsDteControlEntry 9}
tsDestIPAddr4 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS 4th IP Address"
::= { tsDteControlEntry 10}
tsDestIPAddr5 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS 5th IP Address"
::= { tsDteControlEntry 11}
tsDTEMode OBJECT-TYPE
SYNTAX INTEGER {
server(1),
client(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS DTE Mode "
::= { tsDteControlEntry 12}
--
-- Route Table
--
tsRouteControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS Route Control Table."
::= { ts-card 3 }
tsRouteControlEntry OBJECT-TYPE
SYNTAX TsRouteControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TS Route control entry."
INDEX { tsPortIndex ,
tsEntry }
::= { tsRouteControlTable 1 }
TsRouteControlEntry ::= SEQUENCE {
tsEntry INTEGER (1..16),
tsNetAddr IpAddress,
tsNetMask IpAddress,
tsGatewayAddr IpAddress,
tsNIAddr IpAddress,
tsMetric INTEGER (1..16)
}
tsEntry OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS routeentry"
::= { tsRouteControlEntry 1}
tsNetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS route net Address"
::= { tsRouteControlEntry 2}
tsNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS route net mask"
::= { tsRouteControlEntry 3}
tsGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS route gateway Address"
::= { tsRouteControlEntry 4}
tsNIAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS route NI Address"
::= { tsRouteControlEntry 5}
tsMetric OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TS Route metric"
::= { tsRouteControlEntry 6}
--
-- TS Frac Map Table
--
tsFracCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsFracCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Assignment Table."
::= { ts-card 4 }
tsFracCtrlEntry OBJECT-TYPE
SYNTAX TsFracCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Index."
INDEX { tsPortIndex ,
tsTSIndex }
::= { tsFracCtrlTable 1 }
TsFracCtrlEntry ::= SEQUENCE {
tsTSIndex INTEGER,
tsInterface INTEGER
}
tsTSIndex OBJECT-TYPE
SYNTAX INTEGER (1..33)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { tsFracCtrlEntry 1 }
tsInterface OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
wan2(3),
wan3(4),
wan4(5),
wan5(6),
wan6(7),
wan7(8),
wan8(9),
wan9(10),
wan10(11),
wan11(12),
wan12(13),
wan13(14),
wan14(15),
wan15(16),
wan16(17),
wan17(18),
wan18(19),
wan19(20),
wan20(21),
wan21(22),
wan22(23),
wan23(24),
wan24(25),
wan25(26),
wan26(27),
wan27(28),
wan28(29),
wan29(30),
wan30(31),
wan31(32),
wan32(33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frac ni if index."
::= { tsFracCtrlEntry 2 }
--
-- Command Control Table
--
tsCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { ts-card 5}
tsCommandControlEntry OBJECT-TYPE
SYNTAX TsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { tsPortIndex }
::= { tsCommandControlTable 1 }
TsCommandControlEntry ::= SEQUENCE {
tsPortReset INTEGER,
tsPortLoadDefault INTEGER
}
tsPortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset TS Port"
::= { tsCommandControlEntry 1 }
tsPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default TS Port"
::= { tsCommandControlEntry 2 }
--
-- SYSTEM Information Table
--
tsSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF TsSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { ts-card 6}
tsSystemInformationEntry OBJECT-TYPE
SYNTAX TsSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { tsPortIndex }
::= { tsSystemInformationTable 1 }
TsSystemInformationEntry ::= SEQUENCE {
tsPROMVersion DisplayString,
tsHWVersion DisplayString
}
tsPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS EPROM Version"
::= { tsSystemInformationEntry 1 }
tsHWVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TS Hardware Version"
::= { tsSystemInformationEntry 2 }
tsTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of TS"
::= { ts-card 100 }
--======================================================================--
--
-- qfxo_card MIB
--
--======================================================================--
--
-- QFXO Control Table
--
qfxoConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxoConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXO Configuration Control Table"
::= { qfxo-card 1 }
qfxoConfigControlEntry OBJECT-TYPE
SYNTAX QFxoConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXO configuration control entry"
INDEX { qfxoConfigControlIndex }
::= { qfxoConfigControlTable 1 }
QFxoConfigControlEntry ::= SEQUENCE {
qfxoConfigControlIndex SmallSlotIndex,
qfxo-A-u-law INTEGER,
qfxo-Tx-gain INTEGER,
qfxo-Rx-gain INTEGER,
qfxo-IMP INTEGER,
qfxo-A-bit INTEGER
}
qfxoConfigControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoConfigControlEntry 1 }
qfxo-A-u-law OBJECT-TYPE
SYNTAX INTEGER {
a-law(1),
u-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qfxoConfigControlEntry 2 }
qfxo-Tx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0dB(1),
gain-3dB(2),
gain-6dB(3),
gain-9dB(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TX_GAIN "
::= { qfxoConfigControlEntry 3 }
qfxo-Rx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0dB(1),
gain-3dB(2),
gain-6dB(3),
gain-9dB(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RX_GAIN "
::= { qfxoConfigControlEntry 4 }
qfxo-IMP OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qfxoConfigControlEntry 5 }
qfxo-A-bit OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
invert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A-BIT "
::= { qfxoConfigControlEntry 6 }
--
-- Command Control Table
--
qfxoCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qfxo-card 2 }
qfxoCommandControlEntry OBJECT-TYPE
SYNTAX QFxoCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qfxoCommandControlIndex }
::= { qfxoCommandControlTable 1 }
QFxoCommandControlEntry ::= SEQUENCE {
qfxoCommandControlIndex SmallSlotIndex,
qfxoPortLoadDefault INTEGER
}
qfxoCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoCommandControlEntry 1 }
qfxoPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXO Port"
::= { qfxoCommandControlEntry 2 }
--
-- QFXOA All Port Config Control Table
--
qfxoaCfgControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaCfgControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA All Port Configuration Control Table"
::= { qfxo-card 3 }
qfxoaCfgControlEntry OBJECT-TYPE
SYNTAX QfxoaCfgControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA all port configuration control entry"
INDEX { qfxoaCfgControlIndex }
::= { qfxoaCfgControlTable 1 }
QfxoaCfgControlEntry ::= SEQUENCE {
qfxoaCfgControlIndex SmallSlotIndex,
qfxoaCfgControlAuLaw INTEGER,
qfxoaCfgControlImpedance INTEGER,
qfxoaCfgControlTrunk INTEGER,
qfxoaCfgControlPolarity INTEGER
}
qfxoaCfgControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxoaCfgControlEntry 1 }
qfxoaCfgControlAuLaw OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qfxoaCfgControlEntry 2 }
qfxoaCfgControlImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qfxoaCfgControlEntry 3 }
qfxoaCfgControlTrunk OBJECT-TYPE
SYNTAX INTEGER {
on-hook(1),
off-hook(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Trunk Condition "
::= { qfxoaCfgControlEntry 4 }
qfxoaCfgControlPolarity OBJECT-TYPE
SYNTAX INTEGER {
reverse(1),
normal(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Line Polarity "
::= { qfxoaCfgControlEntry 5 }
-- QFXO Per Port Signaling Config Control Table
qfxoaPerPortSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaPerPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXO Per Port Signaling Configuration Control Table"
::= { qfxo-card 4 }
qfxoaPerPortSigSetEntry OBJECT-TYPE
SYNTAX QfxoaPerPortSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXO Per port signaling configuration control entry"
INDEX { qfxoaPerPortSigSetIndex ,
qfxoaPerPortSigSetPort ,
qfxoaPerPortSigSetItemIndex }
::= { qfxoaPerPortSigSetTable 1 }
QfxoaPerPortSigSetEntry ::= SEQUENCE {
qfxoaPerPortSigSetIndex SmallSlotIndex,
qfxoaPerPortSigSetPort INTEGER,
qfxoaPerPortSigSetItemIndex INTEGER,
qfxoaPerPortSigSetSigBit DisplayString
}
qfxoaPerPortSigSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxoaPerPortSigSetEntry 1 }
qfxoaPerPortSigSetPort OBJECT-TYPE
SYNTAX INTEGER {
port1(1),
port2(2),
port3(3),
port4(4),
portAll(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { qfxoaPerPortSigSetEntry 2 }
qfxoaPerPortSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
ringing(1),
no-ring(2),
batt-rev(3),
pulse-on(4),
tip-open(5),
off-hook(6),
oos-alarm(7),
ring-gnd(8),
on-hook(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ringing, no-ring, batt-rev, pulse-on, tip-open, off-hook, oos-on, ring-gnd "
::= { qfxoaPerPortSigSetEntry 3 }
qfxoaPerPortSigSetSigBit OBJECT-TYPE
SYNTAX DisplayString (SIZE (4)) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { qfxoaPerPortSigSetEntry 4 }
--
-- QFXOA Per Port Config Control Table
--
qfxoaPerPortCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaPerPortCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA Per Port Configuration Control Table"
::= { qfxo-card 5 }
qfxoaPerPortCfgEntry OBJECT-TYPE
SYNTAX QfxoaPerPortCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA Per Port Configuration control entry"
INDEX { qfxoaPerPortCfgIndex ,
qfxoaPerPortCfgPort }
::= { qfxoaPerPortCfgTable 1 }
QfxoaPerPortCfgEntry ::= SEQUENCE {
qfxoaPerPortCfgIndex SmallSlotIndex,
qfxoaPerPortCfgPort FourPortID,
qfxoaPerPortCfgTxGain DisplayString,
qfxoaPerPortCfgRxGain DisplayString
}
qfxoaPerPortCfgIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoaPerPortCfgEntry 1 }
qfxoaPerPortCfgPort OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-4"
::= { qfxoaPerPortCfgEntry 2 }
qfxoaPerPortCfgTxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { qfxoaPerPortCfgEntry 3 }
qfxoaPerPortCfgRxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { qfxoaPerPortCfgEntry 4 }
--
-- QFXOA SigMode Control Table
--
qfxoaSigModeControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaSigModeControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SigMode control table."
::= { qfxo-card 6 }
qfxoaSigModeControlEntry OBJECT-TYPE
SYNTAX QfxoaSigModeControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the SigMode control table."
INDEX { qfxoaSigModeControlIndex }
::= { qfxoaSigModeControlTable 1 }
QfxoaSigModeControlEntry ::= SEQUENCE {
qfxoaSigModeControlIndex SmallSlotIndex,
qfxoaSigModeControlMode INTEGER
}
qfxoaSigModeControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoaSigModeControlEntry 1 }
qfxoaSigModeControlMode OBJECT-TYPE
SYNTAX INTEGER {
perCard(1),
perPort(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SigMode Mode"
::= { qfxoaSigModeControlEntry 2 }
--
-- QFXOA Per Port Diag InfoTable
--
qfxoaInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA Diag Info Table"
::= { qfxo-card 7 }
qfxoaInfoEntry OBJECT-TYPE
SYNTAX QfxoaInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA Diag Infoentry"
INDEX { qfxoaInfoIndex ,
qfxoaInfoPortIndex }
::= { qfxoaInfoTable 1 }
QfxoaInfoEntry ::= SEQUENCE {
qfxoaInfoIndex SmallSlotIndex,
qfxoaInfoPortIndex TwelvePortID,
qfxoaInfoRing EMOffOn,
qfxoaInfoOffHook EMOffOn,
qfxoaInfoLine EMOffOn,
qfxoaInfoRingGND EMOffOn,
qfxoaInfoBattRev EMOffOn,
qfxoaInfoPulseOn EMOffOn,
qfxoaInfoAlarm EMOffOn,
qfxoaInfoTx DisplayString,
qfxoaInfoRx DisplayString,
qfxoaInfoVoltage DisplayString
}
qfxoaInfoIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoaInfoEntry 1 }
qfxoaInfoPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-4"
::= { qfxoaInfoEntry 2 }
qfxoaInfoRing OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ring "
::= { qfxoaInfoEntry 3}
qfxoaInfoOffHook OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" off hook "
::= { qfxoaInfoEntry 4}
qfxoaInfoLine OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" line broken "
::= { qfxoaInfoEntry 5}
qfxoaInfoRingGND OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ring ground "
::= { qfxoaInfoEntry 6}
qfxoaInfoBattRev OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Battery reverse "
::= { qfxoaInfoEntry 7}
qfxoaInfoPulseOn OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Pulse On "
::= { qfxoaInfoEntry 8}
qfxoaInfoAlarm OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm"
::= { qfxoaInfoEntry 9}
qfxoaInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { qfxoaInfoEntry 10 }
qfxoaInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { qfxoaInfoEntry 11}
qfxoaInfoVoltage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port Line Voltage"
::= { qfxoaInfoEntry 12}
--
-- QFXOA Line Diagnostic Control Table
--
qfxoaDiagSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaDiagSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXOA Diagnostic Control Table."
::= { qfxo-card 8 }
qfxoaDiagSetEntry OBJECT-TYPE
SYNTAX QfxoaDiagSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QFXO diagnostic control table."
INDEX { qfxoaDiagSetSlot }
::= { qfxoaDiagSetTable 1 }
QfxoaDiagSetEntry ::= SEQUENCE {
qfxoaDiagSetSlot SmallSlotIndex,
qfxoaDiagSetTest INTEGER,
qfxoaDiagSetPeriod INTEGER,
qfxoaDiagSetRemain INTEGER
}
qfxoaDiagSetSlot OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoaDiagSetEntry 1 }
qfxoaDiagSetTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
offHookTest(2),
ringTest(3),
battRevTest(4),
pulseOnTest(5),
tipOpenTest(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QFXOA Test Button"
::= { qfxoaDiagSetEntry 2 }
qfxoaDiagSetPeriod OBJECT-TYPE
SYNTAX INTEGER {
sec10(1),
sec60(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QFXOA Test Button"
::= { qfxoaDiagSetEntry 3 }
qfxoaDiagSetRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { qfxoaDiagSetEntry 4 }
--
-- QFXOA Command Control Table
--
qfxoaCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxoaCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qfxo-card 9 }
qfxoaCommandEntry OBJECT-TYPE
SYNTAX QfxoaCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qfxoaCommandIndex }
::= { qfxoaCommandTable 1 }
QfxoaCommandEntry ::= SEQUENCE {
qfxoaCommandIndex SmallSlotIndex,
qfxoaLoadDefault INTEGER,
qfxoaReset INTEGER
}
qfxoaCommandIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxoaCommandEntry 1 }
qfxoaLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXO Port"
::= { qfxoaCommandEntry 2 }
qfxoaReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXS Port"
::= { qfxoaCommandEntry 3 }
qfxoTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of QFXO"
::= { qfxo-card 100 }
--======================================================================--
--
-- qfxs-card MIB
--
--======================================================================--
--
-- QFXS Control Table
--
qfxsConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Configuration Control Table"
::= { qfxs-card 1 }
qfxsConfigControlEntry OBJECT-TYPE
SYNTAX QFxsConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS configuration control entry"
INDEX { qfxsConfigControlIndex }
::= { qfxsConfigControlTable 1 }
QFxsConfigControlEntry ::= SEQUENCE {
qfxsConfigControlIndex SmallSlotIndex,
qfxs-A-u-law INTEGER,
qfxs-Tx-gain INTEGER,
qfxs-Rx-gain INTEGER,
qfxs-IMP INTEGER,
qfxs-A-bit INTEGER,
qfxs-PLAR-RING-01 INTEGER,
qfxs-PLAR-RING-02 INTEGER,
qfxs-PLAR-RING-03 INTEGER,
qfxs-PLAR-RING-04 INTEGER,
qfxs-CADENCE INTEGER
}
qfxsConfigControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxsConfigControlEntry 1 }
qfxs-A-u-law OBJECT-TYPE
SYNTAX INTEGER {
a-law(1),
u-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qfxsConfigControlEntry 2 }
qfxs-Tx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0dB(1),
gain-3dB(2),
gain-6dB(3),
gain-9dB(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TX_GAIN "
::= { qfxsConfigControlEntry 3 }
qfxs-Rx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0dB(1),
gain-3dB(2),
gain-6dB(3),
gain-9dB(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RX_GAIN "
::= { qfxsConfigControlEntry 4 }
qfxs-IMP OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qfxsConfigControlEntry 5 }
qfxs-A-bit OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
invert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A-BIT "
::= { qfxsConfigControlEntry 6 }
qfxs-PLAR-RING-01 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PLAR_A "
::= { qfxsConfigControlEntry 7 }
qfxs-PLAR-RING-02 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PLAR_B "
::= { qfxsConfigControlEntry 8 }
qfxs-PLAR-RING-03 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PLAR_C "
::= { qfxsConfigControlEntry 9 }
qfxs-PLAR-RING-04 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PLAR_D "
::= { qfxsConfigControlEntry 10 }
qfxs-CADENCE OBJECT-TYPE
SYNTAX INTEGER {
two-sec-on-four-sec-off(1),
one-sec-on-two-sec-off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" CADENCE "
::= { qfxsConfigControlEntry 11 }
--
-- Command Control Table
--
qfxsCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qfxs-card 2 }
qfxsCommandControlEntry OBJECT-TYPE
SYNTAX QFxsCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qfxsCommandControlIndex }
::= { qfxsCommandControlTable 1 }
QFxsCommandControlEntry ::= SEQUENCE {
qfxsCommandControlIndex SmallSlotIndex,
qfxsPortLoadDefault INTEGER
}
qfxsCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxsCommandControlEntry 1 }
qfxsPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXS Port"
::= { qfxsCommandControlEntry 2 }
qfxsTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of QFXS"
::= { qfxs-card 100 }
--
-- QFXS All Port Config Control Table
--
qfxsAllPortConfigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsAllPortConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS All Port Configuration Control Table"
::= { qfxs-card 3 }
qfxsAllPortConfigSetEntry OBJECT-TYPE
SYNTAX QFxsAllPortConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS all port configuration control entry"
INDEX { qfxsAllPortConfigSetIndex }
::= { qfxsAllPortConfigSetTable 1 }
QFxsAllPortConfigSetEntry ::= SEQUENCE {
qfxsAllPortConfigSetIndex SmallSlotIndex,
qfxsAllPortConfigSetA-u-law INTEGER,
qfxsAllPortConfigSetImpedance INTEGER,
-- qfxsAllPortConfigSetTx-gain
-- DisplayString,
-- qfxsAllPortConfigSetRx-gain
-- DisplayString,
qfxsAllPortConfigSetRing-cadence INTEGER,
qfxsAllPortConfigSetRing-Freq INTEGER,
qfxsAllPortConfigSetMetering-pulse INTEGER,
qfxsAllPortConfigSetMetering-freq INTEGER,
qfxsAllPortConfigSetMetering-level INTEGER
}
qfxsAllPortConfigSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsAllPortConfigSetEntry 1 }
qfxsAllPortConfigSetA-u-law OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qfxsAllPortConfigSetEntry 2 }
qfxsAllPortConfigSetImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qfxsAllPortConfigSetEntry 3 }
-- qfxsAllPortConfigSetTx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " TX-GAIN "
-- ::= { qfxsAllPortConfigSetEntry 4 }
-- qfxsAllPortConfigSetRx-gain OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " RX-GAIN "
-- ::= { qfxsAllPortConfigSetEntry 5 }
qfxsAllPortConfigSetRing-cadence OBJECT-TYPE
SYNTAX INTEGER {
cadence-1-on-2-off(1),
cadence-2-on-4-off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ring Cadence "
::= { qfxsAllPortConfigSetEntry 6 }
qfxsAllPortConfigSetRing-Freq OBJECT-TYPE
SYNTAX INTEGER {
freq-20-hz(1),
freq-25-hz(2),
freq-16-7-hz(3),
freq-50-hz(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ring Frequency "
::= { qfxsAllPortConfigSetEntry 7 }
qfxsAllPortConfigSetMetering-pulse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Pulse "
::= { qfxsAllPortConfigSetEntry 8 }
qfxsAllPortConfigSetMetering-freq OBJECT-TYPE
SYNTAX INTEGER {
freq-16k-hz(1),
freq-12k-hz(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Frequency "
::= { qfxsAllPortConfigSetEntry 9 }
qfxsAllPortConfigSetMetering-level OBJECT-TYPE
SYNTAX INTEGER {
level-2-4-vrms(1),
level-1-vrms(2),
unavail(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Metering Level "
::= { qfxsAllPortConfigSetEntry 10 }
--
-- QFXS All Port Signaling Config Control Table
--
qfxsAllPortSigConfigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsAllPortSigConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS All Port Signaling Configuration Control Table"
::= { qfxs-card 4 }
qfxsAllPortSigConfigSetEntry OBJECT-TYPE
SYNTAX QFxsAllPortSigConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS all port signaling configuration control entry"
INDEX { qfxsAllPortSigConfigSetIndex ,
qfxsAllPortSigConfigSetItemIndex ,
qfxsAllPortSigConfigSetSigBitIndex }
::= { qfxsAllPortSigConfigSetTable 1 }
QFxsAllPortSigConfigSetEntry ::= SEQUENCE {
qfxsAllPortSigConfigSetIndex SmallSlotIndex,
qfxsAllPortSigConfigSetItemIndex INTEGER,
qfxsAllPortSigConfigSetSigBitIndex INTEGER,
qfxsAllPortSigConfigSetSigBit INTEGER
}
qfxsAllPortSigConfigSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsAllPortSigConfigSetEntry 1 }
qfxsAllPortSigConfigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
tx-on-hook(1),
tx-off-hook(2),
tx-ring-gnd(3),
plar-tx-off-hook(4),
rx-ring-on(5),
rx-batt-rev-and-pulse-on(6),
rx-oos-alarm(7),
rx-tip-open(8),
rx-plar-rx-ring-on(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"on-hook, off-hook, ring-gnd, ring-on, batt-rev-pulse-on, oos-on, tip-open"
::= { qfxsAllPortSigConfigSetEntry 2 }
qfxsAllPortSigConfigSetSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { qfxsAllPortSigConfigSetEntry 3 }
qfxsAllPortSigConfigSetSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { qfxsAllPortSigConfigSetEntry 4 }
--
-- QFXS Per Port Config Control Table
--
qfxsPerPortConfigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsPerPortConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Per Port Configuration Control Table"
::= { qfxs-card 5 }
qfxsPerPortConfigSetEntry OBJECT-TYPE
SYNTAX QFxsPerPortConfigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Per Port Configuration control entry"
INDEX { qfxsPerPortConfigSetIndex ,
qfxsPerPortConfigSetPortIndex }
::= { qfxsPerPortConfigSetTable 1 }
QFxsPerPortConfigSetEntry ::= SEQUENCE {
qfxsPerPortConfigSetIndex SmallSlotIndex,
qfxsPerPortConfigSetPortIndex TwelvePortID,
qfxsPerPortConfigSetPLAR INTEGER,
qfxsPerPortConfigSetTx-gain DisplayString,
qfxsPerPortConfigSetRx-gain DisplayString
}
qfxsPerPortConfigSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsPerPortConfigSetEntry 1 }
qfxsPerPortConfigSetPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { qfxsPerPortConfigSetEntry 2 }
qfxsPerPortConfigSetPLAR OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port PLAR setting "
::= { qfxsPerPortConfigSetEntry 3 }
qfxsPerPortConfigSetTx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { qfxsPerPortConfigSetEntry 4 }
qfxsPerPortConfigSetRx-gain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { qfxsPerPortConfigSetEntry 5 }
--
-- QFXS Port Status Table
--
qfxsPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Port Status Table"
::= { qfxs-card 6 }
qfxsPortStatusEntry OBJECT-TYPE
SYNTAX QFxsPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Port Status entry"
INDEX { qfxsPortStatusIndex ,
qfxsPortStatusItemIndex ,
qfxsPortStatusPortIndex }
::= { qfxsPortStatusTable 1 }
QFxsPortStatusEntry ::= SEQUENCE {
qfxsPortStatusIndex SmallSlotIndex,
qfxsPortStatusItemIndex INTEGER,
qfxsPortStatusPortIndex TwelvePortID,
qfxsPortStatusStatus DisplayString
}
qfxsPortStatusIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsPortStatusEntry 1 }
qfxsPortStatusItemIndex OBJECT-TYPE
SYNTAX INTEGER {
off-hook(1),
metering-pulse(2),
tip-open(3),
ring-gnd(4),
plar-on(5),
ringing(6),
alarm-on(7),
battery-rev(8),
tx-signaling(9),
rx-signaling(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"off-hook, ring-on, metering-pulse, tip-open, ring-gnd, plar-on, alarm-on"
::= { qfxsPortStatusEntry 2 }
qfxsPortStatusPortIndex OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" port index 1-12 "
::= { qfxsPortStatusEntry 3 }
qfxsPortStatusStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port Status "
::= { qfxsPortStatusEntry 4 }
--
-- QFXS All Port Config Control Table
--
qfxsAllPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsAllPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS All Port Configuration Control Table"
::= { qfxs-card 7 }
qfxsAllPortStatusEntry OBJECT-TYPE
SYNTAX QFxsAllPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS all port configuration control entry"
INDEX { qfxsAllPortStatusIndex }
::= { qfxsAllPortStatusTable 1 }
QFxsAllPortStatusEntry ::= SEQUENCE {
qfxsAllPortStatusIndex SmallSlotIndex,
qfxsAllPortStatusLineCurrent INTEGER,
qfxsAllPortStatusBankSwitch INTEGER,
qfxsAllPortStatusAlarmTone INTEGER,
qfxsAllPortStatusRingVrms INTEGER,
qfxsAllPortStatusDoubleRing INTEGER,
qfxsAllPortStatusInputPower INTEGER,
qfxsAllPortStatusEMC INTEGER
}
qfxsAllPortStatusIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsAllPortStatusEntry 1 }
qfxsAllPortStatusLineCurrent OBJECT-TYPE
SYNTAX INTEGER {
current-20ma(1),
current-25ma(2),
current-30ma(3),
current-35ma(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Line Current"
::= { qfxsAllPortStatusEntry 2 }
qfxsAllPortStatusBankSwitch OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank Switch"
::= { qfxsAllPortStatusEntry 3 }
qfxsAllPortStatusAlarmTone OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm tone"
::= { qfxsAllPortStatusEntry 4 }
qfxsAllPortStatusRingVrms OBJECT-TYPE
SYNTAX INTEGER {
vol-78v(1),
vol-64v(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ring Vrms"
::= { qfxsAllPortStatusEntry 5 }
qfxsAllPortStatusDoubleRing OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Double Ring"
::= { qfxsAllPortStatusEntry 6 }
qfxsAllPortStatusInputPower OBJECT-TYPE
SYNTAX INTEGER {
vol-48v(1),
vol-24v(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Input Power"
::= { qfxsAllPortStatusEntry 7 }
qfxsAllPortStatusEMC OBJECT-TYPE
SYNTAX INTEGER {
ce(1),
ieee1613(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"EMC & safety type"
::= { qfxsAllPortStatusEntry 8 }
--
-- QFXS Line Diagnostic Control Table
--
qfxsDiagTestControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxsDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Diagnostic Control Table."
::= { qfxs-card 8 }
qfxsDiagTestControlEntry OBJECT-TYPE
SYNTAX QfxsDiagTestControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QFXS diagnostic control table."
INDEX { qfxsDiagTestControlIndex }
::= { qfxsDiagTestControlTable 1 }
QfxsDiagTestControlEntry ::= SEQUENCE {
qfxsDiagTestControlIndex SmallSlotIndex,
qfxsDiagTestControlType INTEGER,
qfxsDiagTestControlPeroid INTEGER,
qfxsDiagTestControlRemainTime INTEGER
}
qfxsDiagTestControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsDiagTestControlEntry 1 }
qfxsDiagTestControlType OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
ring-test(2),
battery-reverse(3),
channel-swap(4),
metering-pulse-test(5),
tip-open-test(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QFXS Test Button"
::= { qfxsDiagTestControlEntry 2 }
qfxsDiagTestControlPeroid OBJECT-TYPE
SYNTAX INTEGER {
sec-10(1),
sec-60(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QFXS Test peroid"
::= { qfxsDiagTestControlEntry 3 }
qfxsDiagTestControlRemainTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remain time (sec)"
::= { qfxsDiagTestControlEntry 4 }
--
-- All Port Command Control Table
--
qfxsAllPortCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF QFxsAllPortCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qfxs-card 9 }
qfxsAllPortCommandEntry OBJECT-TYPE
SYNTAX QFxsAllPortCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qfxsAllPortCommandIndex }
::= { qfxsAllPortCommandTable 1 }
QFxsAllPortCommandEntry ::= SEQUENCE {
qfxsAllPortCommandIndex SmallSlotIndex,
qfxsAllPortLoadDefault INTEGER,
qfxsAllPortReset INTEGER
}
qfxsAllPortCommandIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qfxsAllPortCommandEntry 1 }
qfxsAllPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXS Port"
::= { qfxsAllPortCommandEntry 2 }
qfxsAllPortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QFXS Port"
::= { qfxsAllPortCommandEntry 3 }
--
-- QFXS DTMF TEST Table
--
qfxsDiagDtmfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxsDiagDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Diagnostic Control Table."
::= { qfxs-card 10 }
qfxsDiagDtmfEntry OBJECT-TYPE
SYNTAX QfxsDiagDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QFXS diagnostic dtmf table."
INDEX { qfxsDiagDtmfIndex }
::= { qfxsDiagDtmfTable 1 }
QfxsDiagDtmfEntry ::= SEQUENCE {
qfxsDiagDtmfIndex SmallSlotIndex,
qfxsDiagDtmfRemainTime INTEGER,
qfxsDiagDtmfTone INTEGER,
qfxsDiagDtmfResult DisplayString
}
qfxsDiagDtmfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsDiagDtmfEntry 1 }
qfxsDiagDtmfRemainTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remain time (sec)"
::= { qfxsDiagDtmfEntry 2 }
qfxsDiagDtmfTone OBJECT-TYPE
SYNTAX INTEGER {
n1(2),
n2(3),
n3(4),
n4(5),
n5(6),
n6(7),
n7(8),
n8(9),
n9(10),
n0(11),
asterisk(12),
pound(13),
a(14),
b(15),
c(16),
d(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Test Tone"
::= { qfxsDiagDtmfEntry 3 }
qfxsDiagDtmfResult OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone Result"
::= { qfxsDiagDtmfEntry 4 }
--
-- QFXS Port DTMF TEST Table
--
qfxsPortDtmfTable OBJECT-TYPE
SYNTAX SEQUENCE OF QfxsPortDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QFXS Port DTMF Test Table."
::= { qfxs-card 11 }
qfxsPortDtmfEntry OBJECT-TYPE
SYNTAX QfxsPortDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QFXS diagnostic port dtmf table."
INDEX { qfxsPortDtmfIndex }
::= { qfxsPortDtmfTable 1 }
QfxsPortDtmfEntry ::= SEQUENCE {
qfxsPortDtmfIndex SmallSlotIndex,
qfxsPortDtmfPort INTEGER,
qfxsPortDtmfTone1 INTEGER,
qfxsPortDtmfTone2 INTEGER,
qfxsPortDtmfTone3 INTEGER,
qfxsPortDtmfTone4 INTEGER,
qfxsPortDtmfTone5 INTEGER,
qfxsPortDtmfTone6 INTEGER,
qfxsPortDtmfTone7 INTEGER,
qfxsPortDtmfTone8 INTEGER,
qfxsPortDtmfTone9 INTEGER,
qfxsPortDtmfTone0 INTEGER
}
qfxsPortDtmfIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qfxsPortDtmfEntry 1 }
qfxsPortDtmfPort OBJECT-TYPE
SYNTAX INTEGER {
port1(1),
port2(2),
port3(3),
port4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Test Port"
::= { qfxsPortDtmfEntry 2}
qfxsPortDtmfTone1 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone1"
::= { qfxsPortDtmfEntry 3}
qfxsPortDtmfTone2 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone2"
::= { qfxsPortDtmfEntry 4}
qfxsPortDtmfTone3 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone3"
::= { qfxsPortDtmfEntry 5}
qfxsPortDtmfTone4 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone4"
::= { qfxsPortDtmfEntry 6}
qfxsPortDtmfTone5 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone5"
::= { qfxsPortDtmfEntry 7}
qfxsPortDtmfTone6 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone6"
::= { qfxsPortDtmfEntry 8}
qfxsPortDtmfTone7 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone7"
::= { qfxsPortDtmfEntry 9}
qfxsPortDtmfTone8 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone8"
::= { qfxsPortDtmfEntry 10}
qfxsPortDtmfTone9 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone9"
::= { qfxsPortDtmfEntry 11}
qfxsPortDtmfTone0 OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
testing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test Tone0"
::= { qfxsPortDtmfEntry 12}
--======================================================================--
--
-- qem-card MIB
--
--======================================================================--
--
-- QEM Control Table
--
qemConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Configuration Control Table"
::= { qem-card 1 }
qemConfigControlEntry OBJECT-TYPE
SYNTAX QemConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemConfigControlIndex }
::= { qemConfigControlTable 1 }
QemConfigControlEntry ::= SEQUENCE {
qemConfigControlIndex SmallSlotIndex,
qem-Side INTEGER,
qem-Line INTEGER,
qem-Signaling INTEGER,
qem-A-u-law INTEGER,
qem-Tx-gain INTEGER,
qem-Rx-gain INTEGER,
qem-IMP INTEGER,
qem-AB-bit INTEGER
}
qemConfigControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemConfigControlEntry 1 }
qem-Side OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
a-b(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Side "
::= { qemConfigControlEntry 2 }
qem-Line OBJECT-TYPE
SYNTAX INTEGER {
line-2-wire(1),
line-4-wire(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Line "
::= { qemConfigControlEntry 3 }
qem-Signaling OBJECT-TYPE
SYNTAX INTEGER {
none(1),
type-4(2),
type-2(3),
na(4),
type-1(5),
type-5(6),
type-3(7),
tx-only(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Line "
::= { qemConfigControlEntry 4 }
qem-A-u-law OBJECT-TYPE
SYNTAX INTEGER {
a-law(1),
u-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qemConfigControlEntry 5 }
qem-Tx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-dB(1),
gain-neg-3-dB(2),
gain-neg-6-dB(3),
gain-neg-9-dB(4),
gain-7-dB(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TX_GAIN "
::= { qemConfigControlEntry 6 }
qem-Rx-gain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-dB(1),
gain-neg-3-dB(2),
gain-neg-6-dB(3),
gain-neg-9-dB(4),
gain-10-dB(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" RX_GAIN "
::= { qemConfigControlEntry 7 }
qem-IMP OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qemConfigControlEntry 8 }
qem-AB-bit OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
invert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" AB-BIT "
::= { qemConfigControlEntry 9 }
--
-- Line Status Table
--
qemStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Status Table."
::= { qem-card 2 }
qemStatusEntry OBJECT-TYPE
SYNTAX QemStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QE&M status table."
INDEX { qemStatusIndex }
::= { qemStatusTable 1 }
QemStatusEntry ::= SEQUENCE {
qemStatusIndex SmallSlotIndex,
qemE1 INTEGER,
qemE2 INTEGER,
qemE3 INTEGER,
qemE4 INTEGER,
qemM1 INTEGER,
qemM2 INTEGER,
qemM3 INTEGER,
qemM4 INTEGER,
qemAlarm1 INTEGER,
qemAlarm2 INTEGER,
qemAlarm3 INTEGER,
qemAlarm4 INTEGER,
qemPower INTEGER,
qemSupport48V INTEGER
}
qemStatusIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemStatusEntry 1 }
qemE1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E1"
::= { qemStatusEntry 3 }
qemE2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E2"
::= { qemStatusEntry 4 }
qemE3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E3"
::= { qemStatusEntry 5 }
qemE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E4"
::= { qemStatusEntry 6 }
qemM1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M1"
::= { qemStatusEntry 7 }
qemM2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M2"
::= { qemStatusEntry 8 }
qemM3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M3"
::= { qemStatusEntry 9 }
qemM4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M4"
::= { qemStatusEntry 10 }
qemAlarm1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M Alarm1"
::= { qemStatusEntry 11 }
qemAlarm2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M Alarm2"
::= { qemStatusEntry 12 }
qemAlarm3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M Alarm3"
::= { qemStatusEntry 13 }
qemAlarm4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M Alarm4"
::= { qemStatusEntry 14 }
qemPower OBJECT-TYPE
SYNTAX INTEGER {
negatibe-48V(1),
begative-24V(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M Power Modul"
::= { qemStatusEntry 15 }
qemSupport48V OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M supoort 48V"
::= { qemStatusEntry 16 }
--
-- Line Diagnostic Control Table
--
qemDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Diagnostic Control Table."
::= { qem-card 3 }
qemDiagControlEntry OBJECT-TYPE
SYNTAX QemDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QE&M diagnostic control table."
INDEX { qemDiagControlIndex }
::= { qemDiagControlTable 1 }
QemDiagControlEntry ::= SEQUENCE {
qemDiagControlIndex SmallSlotIndex,
qemTEST INTEGER,
qem-E1 INTEGER,
qem-E2 INTEGER,
qem-E3 INTEGER,
qem-E4 INTEGER,
qem-M1 INTEGER,
qem-M2 INTEGER,
qem-M3 INTEGER,
qem-M4 INTEGER
}
qemDiagControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemDiagControlEntry 1 }
qemTEST OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
start(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QE&M E1"
::= { qemDiagControlEntry 2 }
qem-E1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E1"
::= { qemDiagControlEntry 3 }
qem-E2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E2"
::= { qemDiagControlEntry 4 }
qem-E3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E3"
::= { qemDiagControlEntry 5 }
qem-E4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M E4"
::= { qemDiagControlEntry 6 }
qem-M1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M1"
::= { qemDiagControlEntry 7 }
qem-M2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M2"
::= { qemDiagControlEntry 8 }
qem-M3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M3"
::= { qemDiagControlEntry 9 }
qem-M4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
null(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QE&M M4"
::= { qemDiagControlEntry 10 }
--
-- Command Control Table
--
qemCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qem-card 4 }
qemCommandControlEntry OBJECT-TYPE
SYNTAX QemCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qemCommandControlIndex }
::= { qemCommandControlTable 1 }
QemCommandControlEntry ::= SEQUENCE {
qemCommandControlIndex SmallSlotIndex,
qemPortLoadDefault INTEGER
}
qemCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemCommandControlEntry 1 }
qemPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default QE&M CONF"
::= { qemCommandControlEntry 2 }
qemTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of QEM"
::= { qem-card 100 }
qemPerPortConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Configuration Control Table"
::= { qem-card 5 }
qemPerPortConfigControlEntry OBJECT-TYPE
SYNTAX QemPerPortConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortConfigControlIndex }
::= { qemPerPortConfigControlTable 1 }
QemPerPortConfigControlEntry ::= SEQUENCE {
qemPerPortConfigControlIndex SmallSlotIndex,
qem2-Side INTEGER,
qem2-Line INTEGER,
qem2-Signaling INTEGER,
qem2-A-u-law INTEGER,
qem2-IMP INTEGER,
qem2-Trunk INTEGER
}
qemPerPortConfigControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortConfigControlEntry 1 }
qem2-Side OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
a-b(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Side "
::= { qemPerPortConfigControlEntry 2 }
qem2-Line OBJECT-TYPE
SYNTAX INTEGER {
line-2-wire(1),
line-4-wire(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Line "
::= { qemPerPortConfigControlEntry 3 }
qem2-Signaling OBJECT-TYPE
SYNTAX INTEGER {
none(1),
type-4(2),
type-2(3),
na(4),
type-1(5),
type-5(6),
type-3(7),
tx-only(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" QE&M Line "
::= { qemPerPortConfigControlEntry 4 }
qem2-A-u-law OBJECT-TYPE
SYNTAX INTEGER {
a-law(1),
u-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qemPerPortConfigControlEntry 5 }
qem2-IMP OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qemPerPortConfigControlEntry 6 }
qem2-Trunk OBJECT-TYPE
SYNTAX INTEGER {
on-HOOK(1),
off-HOOK(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Trunk Condition"
::= { qemPerPortConfigControlEntry 7 }
qemPerPortGainTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortGainEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Gain Table"
::= { qem-card 6 }
qemPerPortGainEntry OBJECT-TYPE
SYNTAX QemPerPortGainEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortGainIndex }
::= { qemPerPortGainTable 1 }
QemPerPortGainEntry ::= SEQUENCE {
qemPerPortGainIndex SmallSlotIndex,
qem-L1-TX DisplayString,
qem-L2-TX DisplayString,
qem-L3-TX DisplayString,
qem-L4-TX DisplayString,
qem-L1-RX DisplayString,
qem-L2-RX DisplayString,
qem-L3-RX DisplayString,
qem-L4-RX DisplayString
}
qemPerPortGainIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortGainEntry 1 }
qem-L1-TX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TX "
::= { qemPerPortGainEntry 2 }
qem-L2-TX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TX "
::= { qemPerPortGainEntry 3 }
qem-L3-TX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TX "
::= { qemPerPortGainEntry 4 }
qem-L4-TX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TX "
::= { qemPerPortGainEntry 5 }
qem-L1-RX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RX "
::= { qemPerPortGainEntry 6 }
qem-L2-RX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RX "
::= { qemPerPortGainEntry 7 }
qem-L3-RX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RX "
::= { qemPerPortGainEntry 8 }
qem-L4-RX OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RX "
::= { qemPerPortGainEntry 9 }
qemPerPortTXSignalBitTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortTXSignalBitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Gain Table"
::= { qem-card 7 }
qemPerPortTXSignalBitEntry OBJECT-TYPE
SYNTAX QemPerPortTXSignalBitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortTXSignalBitIndex }
::= { qemPerPortTXSignalBitTable 1 }
QemPerPortTXSignalBitEntry ::= SEQUENCE {
qemPerPortTXSignalBitIndex SmallSlotIndex,
qem-OnHook-1 INTEGER,
qem-OnHook-2 INTEGER,
qem-OnHook-3 INTEGER,
qem-OnHook-4 INTEGER,
qem-OffHook-1 INTEGER,
qem-OffHook-2 INTEGER,
qem-OffHook-3 INTEGER,
qem-OffHook-4 INTEGER
}
qemPerPortTXSignalBitIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortTXSignalBitEntry 1 }
qem-OnHook-1 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 1 "
::= { qemPerPortTXSignalBitEntry 2 }
qem-OnHook-2 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 2 "
::= { qemPerPortTXSignalBitEntry 3 }
qem-OnHook-3 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 3 "
::= { qemPerPortTXSignalBitEntry 4 }
qem-OnHook-4 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 4 "
::= { qemPerPortTXSignalBitEntry 5 }
qem-OffHook-1 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OFF HOOK 1 "
::= { qemPerPortTXSignalBitEntry 6 }
qem-OffHook-2 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OFF HOOK 2 "
::= { qemPerPortTXSignalBitEntry 7 }
qem-OffHook-3 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OFF HOOK 3 "
::= { qemPerPortTXSignalBitEntry 8 }
qem-OffHook-4 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OFF HOOK 4 "
::= { qemPerPortTXSignalBitEntry 9 }
qemPerPortRXSignalBitTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortRXSignalBitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Gain Table"
::= { qem-card 8 }
qemPerPortRXSignalBitEntry OBJECT-TYPE
SYNTAX QemPerPortRXSignalBitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortRXSignalBitIndex }
::= { qemPerPortRXSignalBitTable 1 }
QemPerPortRXSignalBitEntry ::= SEQUENCE {
qemPerPortRXSignalBitIndex SmallSlotIndex,
qem-OpenRelay-1 INTEGER,
qem-OpenRelay-2 INTEGER,
qem-OpenRelay-3 INTEGER,
qem-OpenRelay-4 INTEGER,
qem-CloseRelay-1 INTEGER,
qem-CloseRelay-2 INTEGER,
qem-CloseRelay-3 INTEGER,
qem-CloseRelay-4 INTEGER,
qem-OosAlarm-1 INTEGER,
qem-OosAlarm-2 INTEGER,
qem-OosAlarm-3 INTEGER,
qem-OosAlarm-4 INTEGER
}
qemPerPortRXSignalBitIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortRXSignalBitEntry 1 }
qem-OpenRelay-1 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Open1 "
::= { qemPerPortRXSignalBitEntry 2 }
qem-OpenRelay-2 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Open2 "
::= { qemPerPortRXSignalBitEntry 3 }
qem-OpenRelay-3 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Open 3 "
::= { qemPerPortRXSignalBitEntry 4 }
qem-OpenRelay-4 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Open 4 "
::= { qemPerPortRXSignalBitEntry 5 }
qem-CloseRelay-1 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Close 1 "
::= { qemPerPortRXSignalBitEntry 6 }
qem-CloseRelay-2 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Close2 "
::= { qemPerPortRXSignalBitEntry 7 }
qem-CloseRelay-3 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Close3 "
::= { qemPerPortRXSignalBitEntry 8 }
qem-CloseRelay-4 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem-RELAY-Close 4 "
::= { qemPerPortRXSignalBitEntry 9 }
qem-OosAlarm-1 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 1 "
::= { qemPerPortRXSignalBitEntry 10 }
qem-OosAlarm-2 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 2 "
::= { qemPerPortRXSignalBitEntry 11 }
qem-OosAlarm-3 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 3 "
::= { qemPerPortRXSignalBitEntry 12 }
qem-OosAlarm-4 OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
do-not-care(3),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ON HOOK 4 "
::= { qemPerPortRXSignalBitEntry 13 }
qemPerPortLEDTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortLEDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Gain Table"
::= { qem-card 9 }
qemPerPortLEDEntry OBJECT-TYPE
SYNTAX QemPerPortLEDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortLEDIndex }
::= { qemPerPortLEDTable 1 }
QemPerPortLEDEntry ::= SEQUENCE {
qemPerPortLEDIndex SmallSlotIndex,
qem-Led-1 INTEGER,
qem-Led-2 INTEGER,
qem-Led-3 INTEGER,
qem-Led-4 INTEGER,
qem-Led-R INTEGER,
qem-Led-Y INTEGER
}
qemPerPortLEDIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortLEDEntry 1 }
qem-Led-1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED 1 "
::= { qemPerPortLEDEntry 2 }
qem-Led-2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED 2 "
::= { qemPerPortLEDEntry 3 }
qem-Led-3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED 3 "
::= { qemPerPortLEDEntry 4 }
qem-Led-4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED 4 "
::= { qemPerPortLEDEntry 5 }
qem-Led-R OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED R "
::= { qemPerPortLEDEntry 6 }
qem-Led-Y OBJECT-TYPE
SYNTAX INTEGER {
off(1),
flash-1Hz(2),
flash-8Hz(3),
on(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem LED Y "
::= { qemPerPortLEDEntry 7 }
qemPerPortTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Test Table"
::= { qem-card 10 }
qemPerPortTestEntry OBJECT-TYPE
SYNTAX QemPerPortTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M configuration control entry"
INDEX { qemPerPortTestIndex }
::= { qemPerPortTestTable 1 }
QemPerPortTestEntry ::= SEQUENCE {
qemPerPortTestIndex SmallSlotIndex,
qem-TestMode INTEGER,
qem-TestPeriod INTEGER,
qem-TestStatus INTEGER
}
qemPerPortTestIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortTestEntry 1 }
qem-TestMode OBJECT-TYPE
SYNTAX INTEGER {
none(1),
off-Hook-test(2),
loopback-test(3),
led-display-test(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem Test Mode "
::= { qemPerPortTestEntry 2 }
qem-TestPeriod OBJECT-TYPE
SYNTAX INTEGER {
none(1),
sec-10(2),
sec-300(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem Test Period "
::= { qemPerPortTestEntry 3 }
qem-TestStatus OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
start(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem Test Period "
::= { qemPerPortTestEntry 4 }
qemPerPortResetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QemPerPortResetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M ResetTable"
::= { qem-card 11 }
qemPerPortResetEntry OBJECT-TYPE
SYNTAX QemPerPortResetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QE&M Reset control entry"
INDEX { qemPerPortResetIndex }
::= { qemPerPortResetTable 1 }
QemPerPortResetEntry ::= SEQUENCE {
qemPerPortResetIndex SmallSlotIndex,
qem-Reset INTEGER
}
qemPerPortResetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { qemPerPortResetEntry 1 }
qem-Reset OBJECT-TYPE
SYNTAX INTEGER {
none(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"qem Reset Mode "
::= { qemPerPortResetEntry 2 }
--======================================================================--
--======================================================================--
-- conference-card MIB
--======================================================================--
--======================================================================--
--
-- Basic Control Table
--
confBasicControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfBasicControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference basic control table."
::= { conference-card 1 }
confBasicControlEntry OBJECT-TYPE
SYNTAX ConfBasicControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference basic control table."
INDEX { confIndex }
::= { confBasicControlTable 1 }
ConfBasicControlEntry ::= SEQUENCE {
confIndex LargeSlotIndex,
confConferenceID INTEGER,
confFXS-L1-PhoneNumber INTEGER,
confFXS-L2-PhoneNumber INTEGER,
confEM-L3-PhoneNumber INTEGER,
confEM-L4-PhoneNumber INTEGER,
confWanRate INTEGER,
confFXS-L1-Conference INTEGER,
confFXS-L2-Conference INTEGER,
confEM-L3-Conference INTEGER,
confEM-L4-Conference INTEGER,
confMediaType INTEGER,
confEchoCanceller INTEGER,
confPhoneMode INTEGER
}
confIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confBasicControlEntry 1 }
confConferenceID OBJECT-TYPE
SYNTAX INTEGER (0..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The conference card ID"
::= { confBasicControlEntry 2 }
confFXS-L1-PhoneNumber OBJECT-TYPE
SYNTAX INTEGER (0..89)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS(L1) phone number"
::= { confBasicControlEntry 3 }
confFXS-L2-PhoneNumber OBJECT-TYPE
SYNTAX INTEGER (0..89)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS(L2) phone number"
::= { confBasicControlEntry 4 }
confEM-L3-PhoneNumber OBJECT-TYPE
SYNTAX INTEGER (0..89)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"EM(L3) phone number"
::= { confBasicControlEntry 5 }
confEM-L4-PhoneNumber OBJECT-TYPE
SYNTAX INTEGER (0..89)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"EM(L4) phone number"
::= { confBasicControlEntry 6 }
confWanRate OBJECT-TYPE
SYNTAX INTEGER {
rate-64Kbs(1),
rate-128Kbs(2),
rate-192Kbs(3),
rate-256Kbs(4),
rate-320Kbs(5),
rate-384Kbs(6),
rate-448Kbs(7),
rate-512Kbs(8),
rate-576Kbs(9),
rate-640Kbs(10),
rate-702Kbs(11),
rate-768Kbs(12),
rate-832Kbs(13),
rate-896Kbs(14),
rate-960Kbs(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN Rate"
::= { confBasicControlEntry 11 }
confFXS-L1-Conference OBJECT-TYPE
SYNTAX INTEGER {
conference-1(1),
conference-2(2),
conference-3(3),
disable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS(L1) Conference Group"
::= { confBasicControlEntry 12 }
confFXS-L2-Conference OBJECT-TYPE
SYNTAX INTEGER {
conference-1(1),
conference-2(2),
conference-3(3),
disable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS(L2) Conference Group"
::= { confBasicControlEntry 13 }
confEM-L3-Conference OBJECT-TYPE
SYNTAX INTEGER {
conference-1(1),
conference-2(2),
conference-3(3),
disable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M(L3) Conference Group"
::= { confBasicControlEntry 14 }
confEM-L4-Conference OBJECT-TYPE
SYNTAX INTEGER {
conference-1(1),
conference-2(2),
conference-3(3),
disable(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M(L4) Conference Group"
::= { confBasicControlEntry 15 }
confMediaType OBJECT-TYPE
SYNTAX INTEGER {
g711(1),
g723(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Media Type"
::= { confBasicControlEntry 16 }
confEchoCanceller OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Echo Canceller"
::= { confBasicControlEntry 17 }
confPhoneMode OBJECT-TYPE
SYNTAX INTEGER {
dailNumber(1),
hotline(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Phone Mode"
::= { confBasicControlEntry 18 }
--
-- FXS Control Table
--
confFxsControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfFxsControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference FXS control table."
::= { conference-card 2 }
confFxsControlEntry OBJECT-TYPE
SYNTAX ConfFxsControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference FXS control table."
INDEX { confFxsCtrlSlotIndex , confFxsCtrlPortIndex }
::= { confFxsControlTable 1 }
ConfFxsControlEntry ::= SEQUENCE {
confFxsCtrlSlotIndex LargeSlotIndex,
confFxsCtrlPortIndex INTEGER,
confFxsCtrlTxGain INTEGER,
confFxsCtrlRxGain INTEGER,
confFxsCtrlCadence INTEGER
}
confFxsCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confFxsControlEntry 1 }
confFxsCtrlPortIndex OBJECT-TYPE
SYNTAX INTEGER {
fxs-l1(1),
fxs-l2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L1 to L2, total 2 ports"
::= { confFxsControlEntry 2 }
confFxsCtrlTxGain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-db(1),
gain-neg-6-db(2),
gain-6-db(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Tx gain"
::= { confFxsControlEntry 3 }
confFxsCtrlRxGain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-db(1),
gain-6-db(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Rx gain"
::= { confFxsControlEntry 4 }
confFxsCtrlCadence OBJECT-TYPE
SYNTAX INTEGER {
cadence-1-on-2-off(2),
cadence-2-on-4-off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS ring cadence"
::= { confFxsControlEntry 5 }
--
-- E&M Control Table
--
confEmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfEmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference E&M control table."
::= { conference-card 3 }
confEmControlEntry OBJECT-TYPE
SYNTAX ConfEmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference E&M control table."
INDEX { confEmCtrlSlotIndex , confEmCtrlPortIndex }
::= { confEmControlTable 1 }
ConfEmControlEntry ::= SEQUENCE {
confEmCtrlSlotIndex LargeSlotIndex,
confEmCtrlPortIndex INTEGER,
confEmCtrlMode INTEGER,
confEmCtrlSide INTEGER,
confEmCtrlType INTEGER,
confEmCtrlTxGain INTEGER,
confEmCtrlRxGain INTEGER,
confEmCtrlCadence INTEGER
}
confEmCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confEmControlEntry 1 }
confEmCtrlPortIndex OBJECT-TYPE
SYNTAX INTEGER {
em-l3(1),
em-l4(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M L3 to L4, total 2 ports"
::= { confEmControlEntry 2 }
confEmCtrlMode OBJECT-TYPE
SYNTAX INTEGER {
standard(1),
master(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M mode"
::= { confEmControlEntry 3 }
confEmCtrlSide OBJECT-TYPE
SYNTAX INTEGER {
side-a(1),
side-b(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M side"
::= { confEmControlEntry 4 }
confEmCtrlType OBJECT-TYPE
SYNTAX INTEGER {
type1(2),
type4(5),
type5(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M type"
::= { confEmControlEntry 5 }
confEmCtrlTxGain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-db(1),
gain-neg-6-db(2),
gain-6-db(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Tx gain"
::= { confEmControlEntry 6 }
confEmCtrlRxGain OBJECT-TYPE
SYNTAX INTEGER {
gain-0-db(1),
gain-4-db(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M Rx gain"
::= { confEmControlEntry 7 }
confEmCtrlCadence OBJECT-TYPE
SYNTAX INTEGER {
cadence-5-on(1),
cadence-1-on-2-off(2),
cadence-2-on-4-off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E&M ring cadence"
::= { confEmControlEntry 8 }
--
-- Conference Status Table
--
confStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference status table."
::= { conference-card 4 }
confStatusEntry OBJECT-TYPE
SYNTAX ConfStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference status table."
INDEX { confStaIndex }
::= { confStatusTable 1 }
ConfStatusEntry ::= SEQUENCE {
confStaIndex LargeSlotIndex,
confStaMappingStatus INTEGER,
confStaFXS-L1-Hook INTEGER,
confStaFXS-L1-Ring INTEGER,
confStaFXS-L2-Hook INTEGER,
confStaFXS-L2-Ring INTEGER,
confStaEM-L3-ELeadHook INTEGER,
confStaEM-L3-MLeadRing INTEGER,
confStaEM-L4-ELeadHook INTEGER,
confStaEM-L4-MLeadRing INTEGER
}
confStaIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confStatusEntry 1 }
confStaMappingStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
fail(2),
port1-fail(3),
port2-fail(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conference mapping status"
::= { confStatusEntry 2 }
confStaFXS-L1-Hook OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L1 hook"
::= { confStatusEntry 3 }
confStaFXS-L1-Ring OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L1 ring"
::= { confStatusEntry 4 }
confStaFXS-L2-Hook OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L2 hook"
::= { confStatusEntry 5 }
confStaFXS-L2-Ring OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L2 ring"
::= { confStatusEntry 6 }
confStaEM-L3-ELeadHook OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M L3 E-lead hook"
::= { confStatusEntry 7 }
confStaEM-L3-MLeadRing OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M L3 M-lead ring"
::= { confStatusEntry 8 }
confStaEM-L4-ELeadHook OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M L4 E-lead hook"
::= { confStatusEntry 9 }
confStaEM-L4-MLeadRing OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"E&M L4 M-lead ring"
::= { confStatusEntry 10 }
--
-- Command Control Table
--
confCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference command control table."
::= { conference-card 5 }
confCommandControlEntry OBJECT-TYPE
SYNTAX ConfCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference command control table."
INDEX { confCmdCtrlIndex }
::= { confCommandControlTable 1 }
ConfCommandControlEntry ::= SEQUENCE {
confCmdCtrlIndex LargeSlotIndex,
confCmdCtrlReset INTEGER,
confCmdCtrlLoadDefault INTEGER
}
confCmdCtrlIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confCommandControlEntry 1 }
confCmdCtrlReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset"
::= { confCommandControlEntry 2 }
confCmdCtrlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default"
::= { confCommandControlEntry 3 }
--
-- RS232 Control Table
--
confRs232ControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfRs232ControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference RS232 control table."
::= { conference-card 6 }
confRs232ControlEntry OBJECT-TYPE
SYNTAX ConfRs232ControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference RS232 control table."
INDEX { confRs232CtrlSlotIndex , confRs232CtrlPortIndex }
::= { confRs232ControlTable 1 }
ConfRs232ControlEntry ::= SEQUENCE {
confRs232CtrlSlotIndex LargeSlotIndex,
confRs232CtrlPortIndex INTEGER,
confRs232CtrlMode INTEGER,
confRs232CtrlBaudRate INTEGER,
confRs232CtrlDataLength INTEGER,
confRs232CtrlStopBit INTEGER,
confRs232CtrlParity INTEGER,
confRs232CtrlRTS INTEGER,
confRs232CtrlOnTimer INTEGER,
confRs232CtrlOffTimer INTEGER
}
confRs232CtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confRs232ControlEntry 1 }
confRs232CtrlPortIndex OBJECT-TYPE
SYNTAX INTEGER {
rs232-d1(1),
rs232-d2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 D1 to D2, total 2 ports"
::= { confRs232ControlEntry 2 }
confRs232CtrlMode OBJECT-TYPE
SYNTAX INTEGER {
slave(1),
master(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 master/slave mode"
::= { confRs232ControlEntry 3 }
confRs232CtrlBaudRate OBJECT-TYPE
SYNTAX INTEGER {
rate-300(1),
rate-600(2),
rate-1200(3),
rate-2400(4),
rate-4800(5),
rate-9600(6),
rate-19200(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 baud rate"
::= { confRs232ControlEntry 4 }
confRs232CtrlDataLength OBJECT-TYPE
SYNTAX INTEGER {
data-8-bits(1),
data-7-bits(2),
data-6-bits(3),
data-5-bits(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 data length"
::= { confRs232ControlEntry 5 }
confRs232CtrlStopBit OBJECT-TYPE
SYNTAX INTEGER {
stop-1-bit(1),
stop-2-bits(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 stop bit"
::= { confRs232ControlEntry 6 }
confRs232CtrlParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
even(2),
odd(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 parity"
::= { confRs232ControlEntry 7 }
confRs232CtrlRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 RTS"
::= { confRs232ControlEntry 8 }
confRs232CtrlOnTimer OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 on timer"
::= { confRs232ControlEntry 9 }
confRs232CtrlOffTimer OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 off timer"
::= { confRs232ControlEntry 10 }
--
-- RS232 Status Table
--
confRs232StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfRs232StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference RS232 status table."
::= { conference-card 7 }
confRs232StatusEntry OBJECT-TYPE
SYNTAX ConfRs232StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference RS232 status table."
INDEX { confRs232StaSlotIndex , confRs232StaPortIndex }
::= { confRs232StatusTable 1 }
ConfRs232StatusEntry ::= SEQUENCE {
confRs232StaSlotIndex LargeSlotIndex,
confRs232StaPortIndex INTEGER,
confRs232StaRTS INTEGER,
confRs232StaCTS INTEGER,
confRs232StaDTR INTEGER,
confRs232StaDSR INTEGER,
confRs232StaDCD INTEGER
}
confRs232StaSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confRs232StatusEntry 1 }
confRs232StaPortIndex OBJECT-TYPE
SYNTAX INTEGER {
rs232-d1(1),
rs232-d2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 D1 to D2, total 2 ports"
::= { confRs232StatusEntry 2 }
confRs232StaRTS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 RTS status"
::= { confRs232StatusEntry 3 }
confRs232StaCTS OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 CTS status"
::= { confRs232StatusEntry 4 }
confRs232StaDTR OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 DTR status"
::= { confRs232StatusEntry 5 }
confRs232StaDSR OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 DSR status"
::= { confRs232StatusEntry 6 }
confRs232StaDCD OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RS232 DCD status"
::= { confRs232StatusEntry 7 }
--
-- RS232 Loopback Table
--
confRs232LoopbackTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfRs232LoopbackEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference RS232 Loopback table."
::= { conference-card 8 }
confRs232LoopbackEntry OBJECT-TYPE
SYNTAX ConfRs232LoopbackEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference RS232 Loopback table."
INDEX { confRs232LBSlotIndex }
::= { confRs232LoopbackTable 1 }
ConfRs232LoopbackEntry ::= SEQUENCE {
confRs232LBSlotIndex LargeSlotIndex,
confRs232D1Loopback INTEGER,
confRs232D2Loopback INTEGER
}
confRs232LBSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confRs232LoopbackEntry 1 }
confRs232D1Loopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
to-local(2),
to-rs232(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 D1 loopback"
::= { confRs232LoopbackEntry 2 }
confRs232D2Loopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
to-local(2),
to-rs232(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RS232 D1 loopback"
::= { confRs232LoopbackEntry 3 }
--
-- Group Call Table
--
confGroupCallTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfGroupCallEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The conference group call table."
::= { conference-card 9 }
confGroupCallEntry OBJECT-TYPE
SYNTAX ConfGroupCallEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the conference group call table."
INDEX { confGroupCallSlotIndex , confGroupCallPortIndex }
::= { confGroupCallTable 1 }
ConfGroupCallEntry ::= SEQUENCE {
confGroupCallSlotIndex LargeSlotIndex,
confGroupCallPortIndex INTEGER,
confGroupCallGroupCall1 INTEGER,
confGroupCallGroupCall2 INTEGER,
confGroupCallGroupCall3 INTEGER,
confGroupCallGroupCall4 INTEGER
}
confGroupCallSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { confGroupCallEntry 1 }
confGroupCallPortIndex OBJECT-TYPE
SYNTAX INTEGER {
fxs-l1(1),
fxs-l2(2),
em-l3(3),
em-l4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FXS L1 to L2, E&M L3 to L4, total 4 ports"
::= { confGroupCallEntry 2 }
confGroupCallGroupCall1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
no-90(2),
no-91(3),
no-92(4),
no-93(5),
no-94(6),
no-95(7),
no-96(8),
no-97(9),
no-98(10),
no-99(11),
no-AA(12),
no-BB(13),
no-CC(14),
no-DD(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Group Call 1 Number"
::= { confGroupCallEntry 3 }
confGroupCallGroupCall2 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
no-90(2),
no-91(3),
no-92(4),
no-93(5),
no-94(6),
no-95(7),
no-96(8),
no-97(9),
no-98(10),
no-99(11),
no-AA(12),
no-BB(13),
no-CC(14),
no-DD(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Group Call 2 Number"
::= { confGroupCallEntry 4 }
confGroupCallGroupCall3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
no-90(2),
no-91(3),
no-92(4),
no-93(5),
no-94(6),
no-95(7),
no-96(8),
no-97(9),
no-98(10),
no-99(11),
no-AA(12),
no-BB(13),
no-CC(14),
no-DD(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Group Call 3 Number"
::= { confGroupCallEntry 5 }
confGroupCallGroupCall4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
no-90(2),
no-91(3),
no-92(4),
no-93(5),
no-94(6),
no-95(7),
no-96(8),
no-97(9),
no-98(10),
no-99(11),
no-AA(12),
no-BB(13),
no-CC(14),
no-DD(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Group Call 4 Number"
::= { confGroupCallEntry 6 }
confTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of CONF"
::= { conference-card 100 }
--======================================================================--
--======================================================================--
-- tri-e1-card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
tri-e1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { tri-e1-card 1 }
tri-e1LineControlEntry OBJECT-TYPE
SYNTAX Tri-E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1LineControlTable 1 }
Tri-E1LineControlEntry ::= SEQUENCE {
tri-e1Index LargeSlotIndex,
tri-e1PortIndex ThreePortID,
tri-e1LineFrame INTEGER,
tri-e1LineCoding INTEGER,
tri-e1Interface INTEGER,
tri-e1FDL INTEGER,
tri-e1FDLSabit INTEGER,
tri-e1AIS INTEGER,
tri-e1RAI INTEGER,
tri-e1CRC INTEGER,
tri-e1IdleCode INTEGER,
tri-e1CASMode INTEGER,
tri-e1SignallingMode INTEGER,
tri-e1CGA INTEGER,
tri-e1OutOfService INTEGER,
tri-e1SNCPdelay Integer32,
tri-e1SNCPsendAIS INTEGER
}
tri-e1Index OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tri-e1LineControlEntry 1 }
tri-e1PortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, total 4 ports."
::= { tri-e1LineControlEntry 2 }
tri-e1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { tri-e1LineControlEntry 3 }
tri-e1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { tri-e1LineControlEntry 4 }
tri-e1Interface OBJECT-TYPE
SYNTAX INTEGER {
twisted-pair(1),
coaxial-cable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that Tri-E1 line use 75/120 Ohm Cable."
::= { tri-e1LineControlEntry 5 }
tri-e1FDL OBJECT-TYPE
SYNTAX INTEGER {
fdl(1),
off(2),
hdlc(3),
ssm(4)
-- ssm-hdlc(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tri-E1 Facility Data Link ON/OFF"
::= { tri-e1LineControlEntry 6 }
tri-e1FDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
sa4-5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tri-E1 Facility Data Link use Sax bit"
::= { tri-e1LineControlEntry 7 }
tri-e1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tri-E1 line Alarm Indication Signal."
::= { tri-e1LineControlEntry 8 }
tri-e1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { tri-e1LineControlEntry 9 }
tri-e1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tri-E1 Cycle Redundancy Check ON/OFF"
::= { tri-e1LineControlEntry 10 }
tri-e1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value.
Do not set idle code to FF if using DS0-SNCP."
::= { tri-e1LineControlEntry 11 }
tri-e1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { tri-e1LineControlEntry 12 }
tri-e1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1),
cd01(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS or CD01"
::= { tri-e1LineControlEntry 13 }
tri-e1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { tri-e1LineControlEntry 14 }
tri-e1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { tri-e1LineControlEntry 15 }
tri-e1SNCPdelay OBJECT-TYPE
SYNTAX Integer32 (-3..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP port delay."
::= { tri-e1LineControlEntry 16 }
tri-e1SNCPsendAIS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP port send AIS."
::= { tri-e1LineControlEntry 17 }
--
-- User Current Performance Table
--
tri-e1UserCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { tri-e1-card 2 }
tri-e1UserCurrentPerfEntry OBJECT-TYPE
SYNTAX Tri-E1UserCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1UserCurrentPerfTable 1 }
Tri-E1UserCurrentPerfEntry ::= SEQUENCE {
tri-e1UserCurrentPerfES INTEGER,
tri-e1UserCurrentPerfSES INTEGER,
tri-e1UserCurrentPerfBES INTEGER,
tri-e1UserCurrentPerfUAS INTEGER,
tri-e1UserCurrentPerfCSS INTEGER,
tri-e1UserCurrentPerfBPV INTEGER,
tri-e1UserCurrentPerfDMs INTEGER,
tri-e1UserCurr15MinTimeElapsed INTEGER,
tri-e1UserValid15MinInterval INTEGER
}
tri-e1UserCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1UserCurrentPerfEntry 2 }
tri-e1UserCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1UserCurrentPerfEntry 3 }
tri-e1UserCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1UserCurrentPerfEntry 4 }
tri-e1UserCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1UserCurrentPerfEntry 5 }
tri-e1UserCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { tri-e1UserCurrentPerfEntry 6 }
tri-e1UserCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1UserCurrentPerfEntry 7 }
tri-e1UserCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1UserCurrentPerfEntry 8 }
tri-e1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { tri-e1UserCurrentPerfEntry 11 }
tri-e1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { tri-e1UserCurrentPerfEntry 12 }
--
-- User Interval Performance Table
--
tri-e1UserIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { tri-e1-card 3 }
tri-e1UserIntervalPerfEntry OBJECT-TYPE
SYNTAX Tri-E1UserIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1UserIntervalPerfNumber }
::= { tri-e1UserIntervalPerfTable 1 }
Tri-E1UserIntervalPerfEntry ::= SEQUENCE {
tri-e1UserIntervalPerfNumber INTEGER (1..96),
tri-e1UserIntervalPerfES INTEGER,
tri-e1UserIntervalPerfSES INTEGER,
tri-e1UserIntervalPerfBES INTEGER,
tri-e1UserIntervalPerfUAS INTEGER,
tri-e1UserIntervalPerfCSS INTEGER,
tri-e1UserIntervalPerfBPV INTEGER,
tri-e1UserIntervalPerfDMs INTEGER
}
tri-e1UserIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { tri-e1UserIntervalPerfEntry 2 }
tri-e1UserIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1UserIntervalPerfEntry 3 }
tri-e1UserIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1UserIntervalPerfEntry 4 }
tri-e1UserIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1UserIntervalPerfEntry 5 }
tri-e1UserIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1UserIntervalPerfEntry 6 }
tri-e1UserIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1UserIntervalPerfEntry 7 }
tri-e1UserIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1UserIntervalPerfEntry 8 }
tri-e1UserIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1UserIntervalPerfEntry 9 }
--
-- User Total Performance Table
--
tri-e1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { tri-e1-card 4 }
tri-e1UserTotalPerfEntry OBJECT-TYPE
SYNTAX Tri-E1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1UserTotalPerfTable 1 }
Tri-E1UserTotalPerfEntry ::= SEQUENCE {
tri-e1UserTotalPerfES INTEGER,
tri-e1UserTotalPerfSES INTEGER,
tri-e1UserTotalPerfBES INTEGER,
tri-e1UserTotalPerfUAS INTEGER,
tri-e1UserTotalPerfCSS INTEGER,
tri-e1UserTotalPerfBPV INTEGER,
tri-e1UserTotalPerfDMs INTEGER
}
tri-e1UserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1UserTotalPerfEntry 2 }
tri-e1UserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1UserTotalPerfEntry 3 }
tri-e1UserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1UserTotalPerfEntry 4 }
tri-e1UserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1UserTotalPerfEntry 5 }
tri-e1UserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1UserTotalPerfEntry 6 }
tri-e1UserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1UserTotalPerfEntry 7 }
tri-e1UserTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1UserTotalPerfEntry 8 }
--
-- User Seven Days Performance Table
--
tri-e1UserSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { tri-e1-card 5 }
tri-e1UserSevenDaysPerfEntry OBJECT-TYPE
SYNTAX Tri-E1UserSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1UserDaysIndex }
::= { tri-e1UserSevenDaysPerfTable 1 }
Tri-E1UserSevenDaysPerfEntry ::= SEQUENCE {
tri-e1UserDaysIndex INTEGER (1..7),
tri-e1UserDateStrIndex DisplayString (SIZE (0..255) ),
tri-e1UserSevenDaysPerfES INTEGER,
tri-e1UserSevenDaysPerfSES INTEGER,
tri-e1UserSevenDaysPerfBES INTEGER,
tri-e1UserSevenDaysPerfUAS INTEGER,
tri-e1UserSevenDaysPerfCSS INTEGER,
tri-e1UserSevenDaysPerfDMs INTEGER,
tri-e1UserSevenDaysPerfBPV INTEGER
}
tri-e1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { tri-e1UserSevenDaysPerfEntry 2 }
tri-e1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { tri-e1UserSevenDaysPerfEntry 3 }
tri-e1UserSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 4 }
tri-e1UserSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 5 }
tri-e1UserSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 6 }
tri-e1UserSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 7 }
tri-e1UserSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 8 }
tri-e1UserSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 9 }
tri-e1UserSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1UserSevenDaysPerfEntry 10 }
--
-- Line Current Performance Table
--
tri-e1LineCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { tri-e1-card 10 }
tri-e1LineCurrentPerfEntry OBJECT-TYPE
SYNTAX Tri-E1LineCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1LineCurrentPerfTable 1 }
Tri-E1LineCurrentPerfEntry ::= SEQUENCE {
tri-e1LineCurrentPerfES INTEGER,
tri-e1LineCurrentPerfSES INTEGER,
tri-e1LineCurrentPerfBES INTEGER,
tri-e1LineCurrentPerfUAS INTEGER,
tri-e1LineCurrentPerfCSS INTEGER,
tri-e1LineCurrentPerfBPV INTEGER,
tri-e1LineCurrentPerfDMs INTEGER,
tri-e1LineCurr15MinTimeElapsed INTEGER,
tri-e1LineValid15MinInterval INTEGER
}
tri-e1LineCurrentPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { tri-e1LineCurrentPerfEntry 2 }
tri-e1LineCurrentPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1LineCurrentPerfEntry 3 }
tri-e1LineCurrentPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1LineCurrentPerfEntry 4 }
tri-e1LineCurrentPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1LineCurrentPerfEntry 5 }
tri-e1LineCurrentPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1LineCurrentPerfEntry 6 }
tri-e1LineCurrentPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1LineCurrentPerfEntry 7 }
tri-e1LineCurrentPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1LineCurrentPerfEntry 8 }
tri-e1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { tri-e1LineCurrentPerfEntry 11 }
tri-e1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { tri-e1LineCurrentPerfEntry 12 }
--
-- Line Interval Performance Table
--
tri-e1LineIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { tri-e1-card 11 }
tri-e1LineIntervalPerfEntry OBJECT-TYPE
SYNTAX Tri-E1LineIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1LineIntervalPerfNumber }
::= { tri-e1LineIntervalPerfTable 1 }
Tri-E1LineIntervalPerfEntry ::= SEQUENCE {
tri-e1LineIntervalPerfNumber INTEGER (1..96),
tri-e1LineIntervalPerfES INTEGER,
tri-e1LineIntervalPerfSES INTEGER,
tri-e1LineIntervalPerfBES INTEGER,
tri-e1LineIntervalPerfUAS INTEGER,
tri-e1LineIntervalPerfCSS INTEGER,
tri-e1LineIntervalPerfBPV INTEGER,
tri-e1LineIntervalPerfDMs INTEGER,
tri-e1LineIntvAvailable INTEGER
}
tri-e1LineIntervalPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { tri-e1LineIntervalPerfEntry 2 }
tri-e1LineIntervalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1LineIntervalPerfEntry 3 }
tri-e1LineIntervalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1LineIntervalPerfEntry 4 }
tri-e1LineIntervalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1LineIntervalPerfEntry 5 }
tri-e1LineIntervalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1LineIntervalPerfEntry 6 }
tri-e1LineIntervalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1LineIntervalPerfEntry 7 }
tri-e1LineIntervalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1LineIntervalPerfEntry 8 }
tri-e1LineIntervalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1LineIntervalPerfEntry 9 }
tri-e1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { tri-e1LineIntervalPerfEntry 10 }
--
-- Line Total Performance Table
--
tri-e1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { tri-e1-card 12 }
tri-e1LineTotalPerfEntry OBJECT-TYPE
SYNTAX Tri-E1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1LineTotalPerfTable 1 }
Tri-E1LineTotalPerfEntry ::= SEQUENCE {
tri-e1LineTotalPerfES INTEGER,
tri-e1LineTotalPerfSES INTEGER,
tri-e1LineTotalPerfBES INTEGER,
tri-e1LineTotalPerfUAS INTEGER,
tri-e1LineTotalPerfCSS INTEGER,
tri-e1LineTotalPerfBPV INTEGER,
tri-e1LineTotalPerfDMs INTEGER
}
tri-e1LineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1LineTotalPerfEntry 2 }
tri-e1LineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1LineTotalPerfEntry 3 }
tri-e1LineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1LineTotalPerfEntry 4 }
tri-e1LineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1LineTotalPerfEntry 5 }
tri-e1LineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1LineTotalPerfEntry 6 }
tri-e1LineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1LineTotalPerfEntry 7 }
tri-e1LineTotalPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1LineTotalPerfEntry 8 }
--
-- Line Seven Days Performance Table
--
tri-e1LineSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { tri-e1-card 13 }
tri-e1LineSevenDaysPerfEntry OBJECT-TYPE
SYNTAX Tri-E1LineSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1LineDaysIndex }
::= { tri-e1LineSevenDaysPerfTable 1 }
Tri-E1LineSevenDaysPerfEntry ::= SEQUENCE {
tri-e1LineDaysIndex INTEGER (1..7),
tri-e1LineDateStrIndex DisplayString (SIZE (0..255) ),
tri-e1LineSevenDaysPerfES INTEGER,
tri-e1LineSevenDaysPerfSES INTEGER,
tri-e1LineSevenDaysPerfBES INTEGER,
tri-e1LineSevenDaysPerfUAS INTEGER,
tri-e1LineSevenDaysPerfCSS INTEGER,
tri-e1LineSevenDaysPerfDMs INTEGER,
tri-e1LineSevenDaysPerfBPV INTEGER
}
tri-e1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { tri-e1LineSevenDaysPerfEntry 2 }
tri-e1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { tri-e1LineSevenDaysPerfEntry 3 }
tri-e1LineSevenDaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 4 }
tri-e1LineSevenDaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 5 }
tri-e1LineSevenDaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 6 }
tri-e1LineSevenDaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 7 }
tri-e1LineSevenDaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 8 }
tri-e1LineSevenDaysPerfDMs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DM Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 9 }
tri-e1LineSevenDaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { tri-e1LineSevenDaysPerfEntry 10 }
--
-- Alarm Queue Table
--
tri-e1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { tri-e1-card 14 }
tri-e1AlarmQueueEntry OBJECT-TYPE
SYNTAX Tri-E1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1AlarmQueueIndex }
::= { tri-e1AlarmQueueTable 1 }
Tri-E1AlarmQueueEntry ::= SEQUENCE {
tri-e1AlarmQueueIndex INTEGER (1..40),
tri-e1AlarmQueueString DisplayString (SIZE(0..255))
}
tri-e1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { tri-e1AlarmQueueEntry 2 }
tri-e1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { tri-e1AlarmQueueEntry 3 }
--
-- Alarm History Table
--
tri-e1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { tri-e1-card 15 }
tri-e1AlarmHistoryEntry OBJECT-TYPE
SYNTAX Tri-E1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { tri-e1Index , tri-e1PortIndex ,
tri-e1AlarmHistoryIndex }
::= { tri-e1AlarmHistoryTable 1 }
Tri-E1AlarmHistoryEntry ::= SEQUENCE {
tri-e1AlarmHistoryIndex INTEGER,
tri-e1Threshold INTEGER,
tri-e1CurrentState INTEGER,
tri-e1CurrentCount INTEGER,
tri-e1Alarm AlarmSeverity
}
tri-e1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
rai-line(1),
ais-line(2),
los-line(3),
lof-line(4),
bpv-line(5),
ess-line(6),
uas-line(7),
css-line(8),
ais-insert(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { tri-e1AlarmHistoryEntry 2 }
tri-e1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { tri-e1AlarmHistoryEntry 3 }
tri-e1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { tri-e1AlarmHistoryEntry 4 }
tri-e1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { tri-e1AlarmHistoryEntry 5 }
tri-e1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { tri-e1AlarmHistoryEntry 6 }
--
-- Line Availability Table
--
tri-e1LineAvailabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { tri-e1-card 16 }
tri-e1LineAvailabilityEntry OBJECT-TYPE
SYNTAX Tri-E1LineAvailabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1LineAvailabilityTable 1 }
Tri-E1LineAvailabilityEntry ::= SEQUENCE {
tri-e1AvailableSeconds DisplayString,
tri-e1UnavailableSeconds DisplayString,
tri-e1LineAvailability DisplayString
}
tri-e1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { tri-e1LineAvailabilityEntry 2 }
tri-e1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { tri-e1LineAvailabilityEntry 3 }
tri-e1LineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { tri-e1LineAvailabilityEntry 4 }
--
-- Alarm Control Table
--
tri-e1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { tri-e1-card 17 }
tri-e1AlarmControlEntry OBJECT-TYPE
SYNTAX Tri-E1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1AlarmControlTable 1 }
Tri-E1AlarmControlEntry ::= SEQUENCE {
tri-e1RAI-Line AlarmSeverity,
tri-e1AIS-Line AlarmSeverity,
tri-e1LOS-Line AlarmSeverity,
tri-e1LOF-Line AlarmSeverity,
tri-e1BPV-Line AlarmSeverity,
tri-e1ESS-Line AlarmSeverity,
tri-e1UAS-Line AlarmSeverity,
tri-e1CSS-Line AlarmSeverity,
tri-e1AISinsert AlarmSeverity
}
tri-e1RAI-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-Line State"
::= { tri-e1AlarmControlEntry 2 }
tri-e1AIS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { tri-e1AlarmControlEntry 3 }
tri-e1LOS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { tri-e1AlarmControlEntry 4 }
tri-e1LOF-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { tri-e1AlarmControlEntry 5 }
tri-e1BPV-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { tri-e1AlarmControlEntry 6 }
tri-e1ESS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { tri-e1AlarmControlEntry 7 }
tri-e1UAS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { tri-e1AlarmControlEntry 8 }
tri-e1CSS-Line OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { tri-e1AlarmControlEntry 9 }
tri-e1AISinsert OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3E1 AIS insert"
::= { tri-e1AlarmControlEntry 10 }
--
-- Threshold Control Table
--
tri-e1ThresholdControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { tri-e1-card 18 }
tri-e1ThresholdControlEntry OBJECT-TYPE
SYNTAX Tri-E1ThresholdControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1ThresholdControlTable 1 }
Tri-E1ThresholdControlEntry ::= SEQUENCE {
tri-e1ThresholdBPV-Line INTEGER,
tri-e1ThresholdESS-Line INTEGER,
tri-e1ThresholdUAS-Line INTEGER,
tri-e1ThresholdCSS-Line INTEGER,
tri-e1ThresholdAISinsert INTEGER
}
tri-e1ThresholdBPV-Line OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line: 10exp-N"
::= { tri-e1ThresholdControlEntry 2 }
tri-e1ThresholdESS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { tri-e1ThresholdControlEntry 3 }
tri-e1ThresholdUAS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { tri-e1ThresholdControlEntry 4 }
tri-e1ThresholdCSS-Line OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { tri-e1ThresholdControlEntry 5 }
tri-e1ThresholdAISinsert OBJECT-TYPE
SYNTAX INTEGER (3..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of 3E1 AIS Insert: 10exp-N"
::= { tri-e1ThresholdControlEntry 6 }
--
-- Line Diagnostic Control Table
--
tri-e1LineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { tri-e1-card 19 }
tri-e1LineDiagControlEntry OBJECT-TYPE
SYNTAX Tri-E1LineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1LineDiagControlTable 1 }
Tri-E1LineDiagControlEntry ::= SEQUENCE {
tri-e1LoopbackType INTEGER,
tri-e1LoopbackStatus INTEGER,
tri-e1PRBSControl INTEGER,
tri-e1PRBSStatus INTEGER,
tri-e1PRBSElapseSeconds INTEGER,
tri-e1PRBSErrorSeconds INTEGER,
tri-e1PRBSErrorCounts INTEGER,
tri-e1InbandLoopbackPeriod INTEGER,
tri-e1remBERTControl INTEGER,
tri-e1remBERTStatus INTEGER,
tri-e1remBERTCounter INTEGER,
tri-e1remBERTElapsed INTEGER,
tri-e1remBERTErrorSeconds INTEGER,
tri-e1remBERTPatternUnsyncSeconds INTEGER
}
tri-e1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local-loopback(2),
payload-loopback(3),
line-loopback(4),
remote-PLB-Active(5),
remote-LLB-Active(6),
remote-PLB-Deactive(7),
remote-LLB-Deactive(8),
remote-DTE1-Active(9),
remote-DTE1-Deactive(10),
remote-DTE2-Active(11),
remote-DTE2-Deactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tri-e1 Loopback Type"
::= { tri-e1LineDiagControlEntry 2 }
tri-e1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tri-e1 Loopback Status"
::= { tri-e1LineDiagControlEntry 3 }
tri-e1PRBSControl OBJECT-TYPE
SYNTAX INTEGER {
prbs-deactive(1),
prbs-active-full(2),
prbs-reset-error-count(3),
prbs-inject-error(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"tri-e1 PRBS Control"
::= { tri-e1LineDiagControlEntry 4 }
tri-e1PRBSStatus OBJECT-TYPE
SYNTAX INTEGER {
prbs-sync(1),
prbs-unsync(2),
prbs-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tri-e1 PRBS Status"
::= { tri-e1LineDiagControlEntry 5 }
tri-e1PRBSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tri-e1 PRBS Elapse Seconds"
::= { tri-e1LineDiagControlEntry 6 }
tri-e1PRBSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tri-e1 PRBS Error Seconds"
::= { tri-e1LineDiagControlEntry 7 }
tri-e1PRBSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"tri-e1 PRBS Error Counts"
::= { tri-e1LineDiagControlEntry 8 }
tri-e1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of Tri-E1 inband local, payload, or line loopback"
::= { tri-e1LineDiagControlEntry 9 }
tri-e1remBERTControl OBJECT-TYPE
SYNTAX INTEGER {
na(0), --//RIKER2021 SilverCreek
bert-off(1),
bert-full(2),
bert-dte1(3),
bert-dte2(4),
bert-inject-error(5),
bert-reset(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"remBert Control"
::= { tri-e1LineDiagControlEntry 11 }
tri-e1remBERTStatus OBJECT-TYPE
SYNTAX INTEGER {
na(0), --//RIKER2021 SilverCreek
bert-sync(1),
bert-unsync(2),
bert-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Status"
::= { tri-e1LineDiagControlEntry 13 }
tri-e1remBERTCounter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Counter"
::= { tri-e1LineDiagControlEntry 14 }
tri-e1remBERTElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Elapsed Time"
::= { tri-e1LineDiagControlEntry 15 }
tri-e1remBERTErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Error Seconds"
::= { tri-e1LineDiagControlEntry 16 }
tri-e1remBERTPatternUnsyncSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remBERT Pattern Unsync Seconds"
::= { tri-e1LineDiagControlEntry 17 }
--
-- Command Control Table
--
tri-e1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { tri-e1-card 20 }
tri-e1CommandControlEntry OBJECT-TYPE
SYNTAX Tri-E1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { tri-e1Index , tri-e1PortIndex }
::= { tri-e1CommandControlTable 1 }
Tri-E1CommandControlEntry ::= SEQUENCE {
tri-e1AlarmQueueReset INTEGER,
tri-e1UserPerfReset INTEGER,
tri-e1AlarmHistoryReset INTEGER,
tri-e1PortReset INTEGER,
tri-e1PortLoadDefault INTEGER
}
tri-e1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { tri-e1CommandControlEntry 2 }
tri-e1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { tri-e1CommandControlEntry 3 }
tri-e1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { tri-e1CommandControlEntry 4 }
tri-e1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Tri-E1 Port"
::= { tri-e1CommandControlEntry 5 }
tri-e1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default Tri-E1 Port"
::= { tri-e1CommandControlEntry 6 }
--
-- SYSTEM Information Table
--
tri-e1SystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { tri-e1-card 21 }
tri-e1SystemInformationEntry OBJECT-TYPE
SYNTAX Tri-E1SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { tri-e1Index }
::= { tri-e1SystemInformationTable 1 }
Tri-E1SystemInformationEntry ::= SEQUENCE {
tri-e1PROMVersion DisplayString,
tri-e1HardwareVersion DisplayString
}
tri-e1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" tri-e1 PROM Version"
::= { tri-e1SystemInformationEntry 2 }
tri-e1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" tri-e1 Hardware Version"
::= { tri-e1SystemInformationEntry 3 }
--
-- 3E1 Customer Information Table
--
triE1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { tri-e1-card 99 }
triE1CustomerInfoEntry OBJECT-TYPE
SYNTAX TriE1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { triE1CISlotIndex , triE1CIPortIndex }
::= { triE1CustomerInfoTable 1 }
TriE1CustomerInfoEntry ::= SEQUENCE {
triE1CISlotIndex LargeSlotIndex,
triE1CIPortIndex ThreePortID,
triE1CICustomerInfo DisplayString (SIZE(0..64))
}
triE1CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triE1CustomerInfoEntry 1 }
triE1CIPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { triE1CustomerInfoEntry 2 }
triE1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { triE1CustomerInfoEntry 3 }
--
-- Remote Link Identification Table
--
tri-e1RemoteLinkIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF Tri-E1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification Table"
::= { tri-e1-card 22 }
tri-e1RemoteLinkIDEntry OBJECT-TYPE
SYNTAX Tri-E1RemoteLinkIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Remote Link Identification entry"
INDEX { tri-e1Index ,
tri-e1PortIndex }
::= { tri-e1RemoteLinkIDTable 1 }
Tri-E1RemoteLinkIDEntry ::= SEQUENCE {
tri-e1RemoteLinkIDType INTEGER,
tri-e1RemoteLinkIDRack INTEGER,
tri-e1RemoteLinkIDSlotNumber INTEGER,
tri-e1RemoteLinkIDPort INTEGER,
tri-e1RemoteLinkIDSerialNumber INTEGER,
tri-e1RemoteLinkIDBackupSlotNUM INTEGER,
tri-e1RemoteLinkIDBackupPort INTEGER
}
tri-e1RemoteLinkIDType OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
cpe(1),
an(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of remote site."
::= { tri-e1RemoteLinkIDEntry 3 }
tri-e1RemoteLinkIDRack OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Rack"
::= { tri-e1RemoteLinkIDEntry 4 }
tri-e1RemoteLinkIDSlotNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification SlotNumber"
::= { tri-e1RemoteLinkIDEntry 5 }
tri-e1RemoteLinkIDPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Port"
::= { tri-e1RemoteLinkIDEntry 6 }
tri-e1RemoteLinkIDSerialNumber OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Serial Number"
::= { tri-e1RemoteLinkIDEntry 7 }
tri-e1RemoteLinkIDBackupSlotNUM OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Slot Number"
::= { tri-e1RemoteLinkIDEntry 8 }
tri-e1RemoteLinkIDBackupPort OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote Link Identification Backup Port"
::= { tri-e1RemoteLinkIDEntry 9 }
tri-e1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 3E1"
::= { tri-e1-card 100 }
--======================================================================--
--======================================================================--
-- 3T1 card MIB
--======================================================================--
--======================================================================--
--
-- Line Control Table
--
triT1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { triT1card 1 }
triT1LineControlEntry OBJECT-TYPE
SYNTAX TriT1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { triT1LCslot , triT1LCport }
::= { triT1LineControlTable 1 }
TriT1LineControlEntry ::= SEQUENCE {
triT1LCslot LargeSlotIndex,
triT1LCport ThreePortID,
triT1LineFrame INTEGER,
triT1LineCoding INTEGER,
triT1Interface INTEGER,
triT1LineBuildOut INTEGER,
triT1Equalizer INTEGER,
triT1AIS INTEGER,
triT1YEL INTEGER,
triT1Inband INTEGER,
triT1IdleCode INTEGER,
triT1CASMode INTEGER,
triT1SignallingMode INTEGER,
triT1CGA INTEGER,
triT1OutOfService INTEGER,
triT1FDL INTEGER,
triT1SNCPdelay Integer32,
triT1SNCPsendAIS INTEGER
}
triT1LCslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineControlEntry 1 }
triT1LCport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineControlEntry 2 }
triT1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esfT1403(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { triT1LineControlEntry 3 }
triT1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { triT1LineControlEntry 4 }
triT1Interface OBJECT-TYPE
SYNTAX INTEGER {
longHaul(1),
shortHaul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that TriT1 line use Long/Short haul."
::= { triT1LineControlEntry 5 }
triT1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo0dB(1),
lboNeg75dB(2),
lboNeg15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 line build out: 0dB, -7.5dB, -15dB."
::= { triT1LineControlEntry 6 }
triT1Equalizer OBJECT-TYPE
SYNTAX INTEGER {
equ0to110Ft(1),
equ110to220ft(2),
equ220to330ft(3),
equ330to440ft(4),
equ440to550ft(5),
equ550to660ft(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 line equalizer."
::= { triT1LineControlEntry 7 }
triT1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 line Alarm Indication Signal."
::= { triT1LineControlEntry 8 }
triT1YEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { triT1LineControlEntry 9 }
triT1Inband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 line inband ON/OFF"
::= { triT1LineControlEntry 10 }
triT1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value.
Do not set idle code to FF if using DS0-SNCP."
::= { triT1LineControlEntry 11 }
triT1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { triT1LineControlEntry 12 }
triT1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS"
::= { triT1LineControlEntry 13 }
triT1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { triT1LineControlEntry 14 }
triT1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { triT1LineControlEntry 15 }
triT1FDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 Facility Data Link ON/OFF"
::= { triT1LineControlEntry 16 }
triT1SNCPdelay OBJECT-TYPE
SYNTAX Integer32 (-3..99)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP port delay."
::= { triT1LineControlEntry 17 }
triT1SNCPsendAIS OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0-SNCP port send AIS."
::= { triT1LineControlEntry 18 }
--
-- User Current Performance Table
--
triT1UserCurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1UserCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { triT1card 2 }
triT1UserCurrPerfEntry OBJECT-TYPE
SYNTAX TriT1UserCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { triT1UCPslot , triT1UCPport }
::= { triT1UserCurrPerfTable 1 }
TriT1UserCurrPerfEntry ::= SEQUENCE {
triT1UCPslot LargeSlotIndex,
triT1UCPport ThreePortID,
triT1UserCurrPerfES Gauge,
triT1UserCurrPerfSES Gauge,
triT1UserCurrPerfBES Gauge,
triT1UserCurrPerfUAS Gauge,
triT1UserCurrPerfCSS Gauge,
triT1UserCurrPerfBPV Gauge,
triT1UserCurrPerfLOFC Gauge,
triT1UserCurr15MinTimeElapsed INTEGER,
triT1UserValid15MinInterval INTEGER
}
triT1UCPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1UserCurrPerfEntry 1 }
triT1UCPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1UserCurrPerfEntry 2 }
triT1UserCurrPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1UserCurrPerfEntry 3 }
triT1UserCurrPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1UserCurrPerfEntry 4 }
triT1UserCurrPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1UserCurrPerfEntry 5 }
triT1UserCurrPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1UserCurrPerfEntry 6 }
triT1UserCurrPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { triT1UserCurrPerfEntry 7 }
triT1UserCurrPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1UserCurrPerfEntry 8 }
triT1UserCurrPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1UserCurrPerfEntry 9 }
triT1UserCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { triT1UserCurrPerfEntry 11 }
triT1UserValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { triT1UserCurrPerfEntry 12 }
--
-- User Interval Performance Table
--
triT1UserIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1UserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { triT1card 3 }
triT1UserIntvPerfEntry OBJECT-TYPE
SYNTAX TriT1UserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { triT1UIPslot , triT1UIPport ,
triT1UserIntvPerfNumber }
::= { triT1UserIntvPerfTable 1 }
TriT1UserIntvPerfEntry ::= SEQUENCE {
triT1UIPslot LargeSlotIndex,
triT1UIPport ThreePortID,
triT1UserIntvPerfNumber INTEGER,
triT1UserIntvPerfES Gauge,
triT1UserIntvPerfSES Gauge,
triT1UserIntvPerfBES Gauge,
triT1UserIntvPerfUAS Gauge,
triT1UserIntvPerfCSS Gauge,
triT1UserIntvPerfBPV Gauge,
triT1UserIntvPerfLOFC Gauge
}
triT1UIPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1UserIntvPerfEntry 1 }
triT1UIPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1UserIntvPerfEntry 2 }
triT1UserIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { triT1UserIntvPerfEntry 3 }
triT1UserIntvPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1UserIntvPerfEntry 4 }
triT1UserIntvPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1UserIntvPerfEntry 5 }
triT1UserIntvPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1UserIntvPerfEntry 6 }
triT1UserIntvPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1UserIntvPerfEntry 7 }
triT1UserIntvPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1UserIntvPerfEntry 8 }
triT1UserIntvPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1UserIntvPerfEntry 9 }
triT1UserIntvPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1UserIntvPerfEntry 10 }
--
-- User Total Performance Table
--
triT1UserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { triT1card 4 }
triT1UserTotalPerfEntry OBJECT-TYPE
SYNTAX TriT1UserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { triT1UTPslot , triT1UTPport }
::= { triT1UserTotalPerfTable 1 }
TriT1UserTotalPerfEntry ::= SEQUENCE {
triT1UTPslot LargeSlotIndex,
triT1UTPport ThreePortID,
triT1UserTotalPerfES Gauge,
triT1UserTotalPerfSES Gauge,
triT1UserTotalPerfBES Gauge,
triT1UserTotalPerfUAS Gauge,
triT1UserTotalPerfCSS Gauge,
triT1UserTotalPerfBPV Gauge,
triT1UserTotalPerfLOFC Gauge
}
triT1UTPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1UserTotalPerfEntry 1 }
triT1UTPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1UserTotalPerfEntry 2 }
triT1UserTotalPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1UserTotalPerfEntry 3 }
triT1UserTotalPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1UserTotalPerfEntry 4 }
triT1UserTotalPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1UserTotalPerfEntry 5 }
triT1UserTotalPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1UserTotalPerfEntry 6 }
triT1UserTotalPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1UserTotalPerfEntry 7 }
triT1UserTotalPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1UserTotalPerfEntry 8 }
triT1UserTotalPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1UserTotalPerfEntry 9 }
--
-- User Seven Days Performance Table
--
triT1User7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1User7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { triT1card 5 }
triT1User7DaysPerfEntry OBJECT-TYPE
SYNTAX TriT1User7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance entry"
INDEX { triT1USPslot , triT1USPport ,
triT1UserDaysIndex }
::= { triT1User7DaysPerfTable 1 }
TriT1User7DaysPerfEntry ::= SEQUENCE {
triT1USPslot LargeSlotIndex,
triT1USPport ThreePortID,
triT1UserDaysIndex INTEGER,
triT1UserDateStrIndex DisplayString,
triT1User7DaysPerfES Gauge,
triT1User7DaysPerfSES Gauge,
triT1User7DaysPerfBES Gauge,
triT1User7DaysPerfUAS Gauge,
triT1User7DaysPerfCSS Gauge
}
triT1USPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1User7DaysPerfEntry 1 }
triT1USPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1User7DaysPerfEntry 2 }
triT1UserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { triT1User7DaysPerfEntry 3 }
triT1UserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { triT1User7DaysPerfEntry 4 }
triT1User7DaysPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1User7DaysPerfEntry 5 }
triT1User7DaysPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1User7DaysPerfEntry 6 }
triT1User7DaysPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1User7DaysPerfEntry 7 }
triT1User7DaysPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1User7DaysPerfEntry 8 }
triT1User7DaysPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1User7DaysPerfEntry 9 }
--
-- Line Current Performance Table
--
triT1LineCurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { triT1card 6 }
triT1LineCurrPerfEntry OBJECT-TYPE
SYNTAX TriT1LineCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { triT1LCPslot , triT1LCPport }
::= { triT1LineCurrPerfTable 1 }
TriT1LineCurrPerfEntry ::= SEQUENCE {
triT1LCPslot LargeSlotIndex,
triT1LCPport ThreePortID,
triT1LineCurrPerfES Gauge,
triT1LineCurrPerfSES Gauge,
triT1LineCurrPerfBES Gauge,
triT1LineCurrPerfUAS Gauge,
triT1LineCurrPerfCSS Gauge,
triT1LineCurrPerfBPV Gauge,
triT1LineCurrPerfLOFC Gauge,
triT1LineCurr15MinTimeElapsed INTEGER,
triT1LineValid15MinInterval INTEGER
}
triT1LCPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineCurrPerfEntry 1 }
triT1LCPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineCurrPerfEntry 2 }
triT1LineCurrPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { triT1LineCurrPerfEntry 3 }
triT1LineCurrPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1LineCurrPerfEntry 4 }
triT1LineCurrPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1LineCurrPerfEntry 5 }
triT1LineCurrPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1LineCurrPerfEntry 6 }
triT1LineCurrPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1LineCurrPerfEntry 7 }
triT1LineCurrPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1LineCurrPerfEntry 8 }
triT1LineCurrPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1LineCurrPerfEntry 9 }
triT1LineCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { triT1LineCurrPerfEntry 11 }
triT1LineValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { triT1LineCurrPerfEntry 12 }
--
-- Line Interval Performance Table
--
triT1LineIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { triT1card 7 }
triT1LineIntvPerfEntry OBJECT-TYPE
SYNTAX TriT1LineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { triT1LIPslot , triT1LIPport ,
triT1LineIntvPerfNumber }
::= { triT1LineIntvPerfTable 1 }
TriT1LineIntvPerfEntry ::= SEQUENCE {
triT1LIPslot LargeSlotIndex,
triT1LIPport ThreePortID,
triT1LineIntvPerfNumber INTEGER,
triT1LineIntvPerfES Gauge,
triT1LineIntvPerfSES Gauge,
triT1LineIntvPerfBES Gauge,
triT1LineIntvPerfUAS Gauge,
triT1LineIntvPerfCSS Gauge,
triT1LineIntvPerfBPV Gauge,
triT1LineIntvPerfLOFC Gauge,
triT1LineIntvAvailable INTEGER
}
triT1LIPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineIntvPerfEntry 1 }
triT1LIPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineIntvPerfEntry 2 }
triT1LineIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index "
::= { triT1LineIntvPerfEntry 3 }
triT1LineIntvPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1LineIntvPerfEntry 4 }
triT1LineIntvPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1LineIntvPerfEntry 5 }
triT1LineIntvPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1LineIntvPerfEntry 6 }
triT1LineIntvPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1LineIntvPerfEntry 7 }
triT1LineIntvPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1LineIntvPerfEntry 8 }
triT1LineIntvPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1LineIntvPerfEntry 9 }
triT1LineIntvPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1LineIntvPerfEntry 10 }
triT1LineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { triT1LineIntvPerfEntry 11 }
--
-- Line Total Performance Table
--
triT1LineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { triT1card 8 }
triT1LineTotalPerfEntry OBJECT-TYPE
SYNTAX TriT1LineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance entry"
INDEX { triT1LTPslot , triT1LTPport }
::= { triT1LineTotalPerfTable 1 }
TriT1LineTotalPerfEntry ::= SEQUENCE {
triT1LTPslot LargeSlotIndex,
triT1LTPport ThreePortID,
triT1LineTotalPerfES Gauge,
triT1LineTotalPerfSES Gauge,
triT1LineTotalPerfBES Gauge,
triT1LineTotalPerfUAS Gauge,
triT1LineTotalPerfCSS Gauge,
triT1LineTotalPerfBPV Gauge,
triT1LineTotalPerfLOFC Gauge
}
triT1LTPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineTotalPerfEntry 1 }
triT1LTPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineTotalPerfEntry 2 }
triT1LineTotalPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1LineTotalPerfEntry 3 }
triT1LineTotalPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1LineTotalPerfEntry 4 }
triT1LineTotalPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1LineTotalPerfEntry 5 }
triT1LineTotalPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1LineTotalPerfEntry 6 }
triT1LineTotalPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1LineTotalPerfEntry 7 }
triT1LineTotalPerfBPV OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { triT1LineTotalPerfEntry 8 }
triT1LineTotalPerfLOFC OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LOFC Error Counter "
::= { triT1LineTotalPerfEntry 9 }
--
-- Line Seven Days Performance Table
--
triT1Line7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1Line7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { triT1card 9 }
triT1Line7DaysPerfEntry OBJECT-TYPE
SYNTAX TriT1Line7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { triT1LSPslot , triT1LSPport ,
triT1LineDaysIndex }
::= { triT1Line7DaysPerfTable 1 }
TriT1Line7DaysPerfEntry ::= SEQUENCE {
triT1LSPslot LargeSlotIndex,
triT1LSPport ThreePortID,
triT1LineDaysIndex INTEGER,
triT1LineDateStrIndex DisplayString,
triT1Line7DaysPerfES Gauge,
triT1Line7DaysPerfSES Gauge,
triT1Line7DaysPerfBES Gauge,
triT1Line7DaysPerfUAS Gauge,
triT1Line7DaysPerfCSS Gauge
}
triT1LSPslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1Line7DaysPerfEntry 1 }
triT1LSPport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1Line7DaysPerfEntry 2 }
triT1LineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { triT1Line7DaysPerfEntry 3 }
triT1LineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { triT1Line7DaysPerfEntry 4 }
triT1Line7DaysPerfES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { triT1Line7DaysPerfEntry 5 }
triT1Line7DaysPerfSES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { triT1Line7DaysPerfEntry 6 }
triT1Line7DaysPerfBES OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { triT1Line7DaysPerfEntry 7 }
triT1Line7DaysPerfUAS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { triT1Line7DaysPerfEntry 8 }
triT1Line7DaysPerfCSS OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { triT1Line7DaysPerfEntry 9 }
--
-- Alarm Queue Table
--
triT1AlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm Queue Table"
::= { triT1card 11 }
triT1AlarmQueueEntry OBJECT-TYPE
SYNTAX TriT1AlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { triT1AQslot , triT1AQport ,
triT1AlarmQueueIndex }
::= { triT1AlarmQueueTable 1 }
TriT1AlarmQueueEntry ::= SEQUENCE {
triT1AQslot LargeSlotIndex,
triT1AQport ThreePortID,
triT1AlarmQueueIndex INTEGER,
triT1AlarmQueueString DisplayString
}
triT1AQslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1AlarmQueueEntry 1 }
triT1AQport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1AlarmQueueEntry 2 }
triT1AlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { triT1AlarmQueueEntry 3 }
triT1AlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { triT1AlarmQueueEntry 4 }
--
-- Alarm History Table
--
triT1AlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { triT1card 12 }
triT1AlarmHistoryEntry OBJECT-TYPE
SYNTAX TriT1AlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { triT1AHslot , triT1AHport ,
triT1AlarmHistoryIndex }
::= { triT1AlarmHistoryTable 1 }
TriT1AlarmHistoryEntry ::= SEQUENCE {
triT1AHslot LargeSlotIndex,
triT1AHport ThreePortID,
triT1AlarmHistoryIndex INTEGER,
triT1Threshold INTEGER,
triT1CurrentState INTEGER,
triT1CurrentCount INTEGER,
triT1Alarm AlarmSeverity
}
triT1AHslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1AlarmHistoryEntry 1 }
triT1AHport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1AlarmHistoryEntry 2 }
triT1AlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
yelLine(1),
aisLine(2),
losLine(3),
lofLine(4),
bpvLine(5),
essLine(6),
uasLine(7),
cssLine(8),
aisInsert(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { triT1AlarmHistoryEntry 3 }
triT1Threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { triT1AlarmHistoryEntry 4 }
triT1CurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { triT1AlarmHistoryEntry 5 }
triT1CurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { triT1AlarmHistoryEntry 6 }
triT1Alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { triT1AlarmHistoryEntry 7 }
--
-- Line Availability Table
--
triT1LineAvailTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 line control table."
::= { triT1card 13 }
triT1LineAvailEntry OBJECT-TYPE
SYNTAX TriT1LineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 line control table."
INDEX { triT1LAslot , triT1LAport }
::= { triT1LineAvailTable 1 }
TriT1LineAvailEntry ::= SEQUENCE {
triT1LAslot LargeSlotIndex,
triT1LAport ThreePortID,
triT1AvailableSeconds DisplayString,
triT1UnavailableSeconds DisplayString,
triT1LineAvail DisplayString
}
triT1LAslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineAvailEntry 1 }
triT1LAport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineAvailEntry 2 }
triT1AvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { triT1LineAvailEntry 3 }
triT1UnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { triT1LineAvailEntry 4 }
triT1LineAvail OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { triT1LineAvailEntry 5 }
--
-- Alarm Control Table
--
triT1AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { triT1card 14 }
triT1AlarmControlEntry OBJECT-TYPE
SYNTAX TriT1AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 alarm control table."
INDEX { triT1ACslot , triT1ACport }
::= { triT1AlarmControlTable 1 }
TriT1AlarmControlEntry ::= SEQUENCE {
triT1ACslot LargeSlotIndex,
triT1ACport ThreePortID,
triT1YELline AlarmSeverity,
triT1AISline AlarmSeverity,
triT1LOSline AlarmSeverity,
triT1LOFline AlarmSeverity,
triT1BPVline AlarmSeverity,
triT1ESSline AlarmSeverity,
triT1UASline AlarmSeverity,
triT1CSSline AlarmSeverity,
triT1AISinsert AlarmSeverity
}
triT1ACslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1AlarmControlEntry 1 }
triT1ACport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1AlarmControlEntry 2 }
triT1YELline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-Line State"
::= { triT1AlarmControlEntry 3 }
triT1AISline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS-Line State"
::= { triT1AlarmControlEntry 4 }
triT1LOSline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-line State"
::= { triT1AlarmControlEntry 5 }
triT1LOFline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF-Line State"
::= { triT1AlarmControlEntry 6 }
triT1BPVline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV-Line State"
::= { triT1AlarmControlEntry 7 }
triT1ESSline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ESS-Line State"
::= { triT1AlarmControlEntry 8 }
triT1UASline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS-Line State"
::= { triT1AlarmControlEntry 9 }
triT1CSSline OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CS-Line State"
::= { triT1AlarmControlEntry 10 }
triT1AISinsert OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 AIS insert"
::= { triT1AlarmControlEntry 11 }
--
-- Threshold Control Table
--
triT1ThresholdCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1ThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { triT1card 15 }
triT1ThresholdCtrlEntry OBJECT-TYPE
SYNTAX TriT1ThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { triT1TCslot , triT1TCport }
::= { triT1ThresholdCtrlTable 1 }
TriT1ThresholdCtrlEntry ::= SEQUENCE {
triT1TCslot LargeSlotIndex,
triT1TCport ThreePortID,
triT1ThresholdBPVline INTEGER,
triT1ThresholdESSline INTEGER,
triT1ThresholdUASline INTEGER,
triT1ThresholdCSSline INTEGER,
triT1ThresholdAISinsert INTEGER
}
triT1TCslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1ThresholdCtrlEntry 1 }
triT1TCport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1ThresholdCtrlEntry 2 }
triT1ThresholdBPVline OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV-Line: 10exp-N"
::= { triT1ThresholdCtrlEntry 3 }
triT1ThresholdESSline OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS-Line "
::= { triT1ThresholdCtrlEntry 4 }
triT1ThresholdUASline OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS-Line "
::= { triT1ThresholdCtrlEntry 5 }
triT1ThresholdCSSline OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS-Line "
::= { triT1ThresholdCtrlEntry 6 }
triT1ThresholdAISinsert OBJECT-TYPE
SYNTAX INTEGER (3..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of 3T1 AIS Insert: 10exp-N"
::= { triT1ThresholdCtrlEntry 7 }
--
-- Line Diagnostic Control Table
--
triT1LineDiagCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1LineDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { triT1card 16 }
triT1LineDiagCtrlEntry OBJECT-TYPE
SYNTAX TriT1LineDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DS1 threshold control table."
INDEX { triT1DCslot , triT1DCport }
::= { triT1LineDiagCtrlTable 1 }
TriT1LineDiagCtrlEntry ::= SEQUENCE {
triT1DCslot LargeSlotIndex,
triT1DCport ThreePortID,
triT1LoopbackType INTEGER,
triT1LoopbackStatus INTEGER,
triT1QRSSControl INTEGER,
triT1QRSSStatus INTEGER,
triT1QRSSElapseSeconds INTEGER,
triT1QRSSErrorSeconds INTEGER,
triT1QRSSErrorCounts INTEGER,
triT1InbandLoopbackPeriod INTEGER
}
triT1DCslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1LineDiagCtrlEntry 1 }
triT1DCport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1LineDiagCtrlEntry 2 }
triT1LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payloadLoopback(3),
lineLoopback(4),
remoteLlbInbandActive(5),
remotePlbAttActive(6),
remotePlbAnsiActive(7),
remoteLlbAnsiActive(8),
remoteLlbInbandDeactive(9),
remotePlbAttDeactive(10),
remotePlbAnsiDeactive(11),
remoteLlbAnsiDeactive(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 Loopback Type"
::= { triT1LineDiagCtrlEntry 3 }
triT1LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopbackNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3T1 Loopback Status"
::= { triT1LineDiagCtrlEntry 4 }
triT1QRSSControl OBJECT-TYPE
SYNTAX INTEGER {
qrssDeactive(1),
qrssActiveFull(2),
qrssResetErrorCount(3),
qrssInjectError(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3T1 QRSS Control"
::= { triT1LineDiagCtrlEntry 5 }
triT1QRSSStatus OBJECT-TYPE
SYNTAX INTEGER {
qrssSync(1),
qrssUnsync(2),
qrssNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3T1 QRSS Status"
::= { triT1LineDiagCtrlEntry 6 }
triT1QRSSElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3T1 QRSS Elapse Seconds"
::= { triT1LineDiagCtrlEntry 7 }
triT1QRSSErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3T1 QRSS Error Seconds"
::= { triT1LineDiagCtrlEntry 8 }
triT1QRSSErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3T1 QRSS Error Counts"
::= { triT1LineDiagCtrlEntry 9 }
triT1InbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of TriT1 inband local, payload, or line loopback"
::= { triT1LineDiagCtrlEntry 10 }
--
-- Command Control Table
--
triT1CommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { triT1card 17 }
triT1CommandControlEntry OBJECT-TYPE
SYNTAX TriT1CommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { triT1CCslot , triT1CCport }
::= { triT1CommandControlTable 1 }
TriT1CommandControlEntry ::= SEQUENCE {
triT1CCslot LargeSlotIndex,
triT1CCport ThreePortID,
triT1AlarmQueueReset INTEGER,
triT1UserPerfReset INTEGER,
triT1AlarmHistoryReset INTEGER,
triT1PortReset INTEGER,
triT1PortLoadDefault INTEGER
}
triT1CCslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1CommandControlEntry 1 }
triT1CCport OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, total 3 ports."
::= { triT1CommandControlEntry 2 }
triT1AlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { triT1CommandControlEntry 3 }
triT1UserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { triT1CommandControlEntry 4 }
triT1AlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { triT1CommandControlEntry 5 }
triT1PortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset TriT1 Port"
::= { triT1CommandControlEntry 6 }
triT1PortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
loadDefault(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default TriT1 Port"
::= { triT1CommandControlEntry 7 }
--
-- SYSTEM Information Table
--
triT1SystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { triT1card 18 }
triT1SystemInfoEntry OBJECT-TYPE
SYNTAX TriT1SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { triT1SIslot }
::= { triT1SystemInfoTable 1 }
TriT1SystemInfoEntry ::= SEQUENCE {
triT1SIslot LargeSlotIndex,
triT1PROMVersion DisplayString,
triT1HardwareVersion DisplayString
}
triT1SIslot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1SystemInfoEntry 1 }
triT1PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" triT1 PROM Version"
::= { triT1SystemInfoEntry 2 }
triT1HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" triT1 Hardware Version"
::= { triT1SystemInfoEntry 3 }
--
-- TriT1 Customer Information Table
--
triT1CustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriT1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Customer Information table."
::= { triT1card 99 }
triT1CustomerInfoEntry OBJECT-TYPE
SYNTAX TriT1CustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Customer Information table."
INDEX { triT1CISlotIndex , triT1CIPortIndex }
::= { triT1CustomerInfoTable 1 }
TriT1CustomerInfoEntry ::= SEQUENCE {
triT1CISlotIndex LargeSlotIndex,
triT1CIPortIndex ThreePortID,
triT1CICustomerInfo DisplayString
}
triT1CISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { triT1CustomerInfoEntry 1 }
triT1CIPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { triT1CustomerInfoEntry 2 }
triT1CICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { triT1CustomerInfoEntry 3 }
triT1TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of TriT1"
::= { triT1card 100 }
--======================================================================--
--======================================================================--
-- small dte card MIB
--======================================================================--
--======================================================================--
--
-- DTE Control Table
--
sdteConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTEConfigControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Configuration Control Table"
::= { sdte-card 1 }
sdteConfigCtrlEntry OBJECT-TYPE
SYNTAX SDTEConfigControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE configuration control entry"
INDEX { sdteIndex }
::= { sdteConfigControlTable 1 }
SDTEConfigControl ::= SEQUENCE {
sdteIndex SmallSlotIndex,
sdteRate INTEGER,
sdteChannel INTEGER,
sdteClock INTEGER,
sdteData INTEGER,
sdteInterface INTEGER,
sdteRTS INTEGER,
sdteTTM INTEGER,
sdteV54 INTEGER
}
sdteIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { sdteConfigCtrlEntry 1 }
sdteRate OBJECT-TYPE
SYNTAX INTEGER {
rate64k(1),
rate56k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Rate "
::= { sdteConfigCtrlEntry 2 }
sdteChannel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Channel: channel numbers designed by MAP."
::= { sdteConfigCtrlEntry 3 }
sdteClock OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Clock Polarity "
::= { sdteConfigCtrlEntry 4 }
sdteData OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
inverted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Data Polarity "
::= { sdteConfigCtrlEntry 5 }
sdteInterface OBJECT-TYPE
SYNTAX INTEGER {
v35(1),
eia530(2),
x21(3),
rs232(4),
rs449(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Interface Type "
::= { sdteConfigCtrlEntry 6 }
sdteRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE RTS Permanent "
::= { sdteConfigCtrlEntry 7 }
sdteTTM OBJECT-TYPE
SYNTAX INTEGER {
off(1)
-- on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE Terminal Timing Mode "
::= { sdteConfigCtrlEntry 8 }
sdteV54 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DTE V54 control "
::= { sdteConfigCtrlEntry 9 }
--
-- Alarm Queue Table
--
-- sdteAlarmQueueTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF SDTEAlarmQueue
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "DTE Alarm Queue Table"
-- ::= { sdte-card 2 }
--
-- sdteAlarmQueueEntry OBJECT-TYPE
-- SYNTAX SDTEAlarmQueue
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "DTE alarm queue entry"
-- INDEX { sdteIndex,
-- sdteAlarmQIndex }
-- ::= { sdteAlarmQueueTable 1 }
--
-- SDTEAlarmQueue ::=
-- SEQUENCE {
-- sdteAlarmQIndex
-- INTEGER (1..40),
-- sdteAlarmQStr
-- DisplayString (SIZE(0..255))
-- }
--
-- sdteAlarmQIndex OBJECT-TYPE
-- SYNTAX INTEGER (1..40)
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Select Alarm Queue Index(1-40)"
-- ::= { sdteAlarmQueueEntry 2 }
--
-- sdteAlarmQStr OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Alarm Queue String"
-- ::= { sdteAlarmQueueEntry 3 }
--
-- Alarm History Table
--
sdteAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTEAlarmHistory
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Alarm History Table"
::= { sdte-card 3 }
sdteAlarmHistoryEntry OBJECT-TYPE
SYNTAX SDTEAlarmHistory
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE alarm history entry"
INDEX { sdteIndex ,
sdteAlarmHIndex }
::= { sdteAlarmHistoryTable 1 }
SDTEAlarmHistory ::= SEQUENCE {
sdteAlarmHIndex INTEGER,
sdteCurrentHState INTEGER,
sdteCountH INTEGER,
sdteAlarmH AlarmSeverity
}
sdteAlarmHIndex OBJECT-TYPE
SYNTAX INTEGER {
dte-alarm(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { sdteAlarmHistoryEntry 2 }
sdteCurrentHState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { sdteAlarmHistoryEntry 3 }
sdteCountH OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { sdteAlarmHistoryEntry 4 }
sdteAlarmH OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { sdteAlarmHistoryEntry 5 }
--
-- Alarm Control Table
--
sdteAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTEAlarmControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { sdte-card 4 }
sdteAlarmCtrlEntry OBJECT-TYPE
SYNTAX SDTEAlarmControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the SDTE alarm control table."
INDEX { sdteIndex }
::= { sdteAlarmControlTable 1 }
SDTEAlarmControl ::= SEQUENCE {
sdteAlarmEn AlarmSeverity
}
sdteAlarmEn OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SDTE-Alarm State"
::= { sdteAlarmCtrlEntry 2 }
--
-- Line Diagnostic Control Table
--
sdteLineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTELineDiagControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Diagnostic Control Table."
::= { sdte-card 5 }
sdteDiagCtrlEntry OBJECT-TYPE
SYNTAX SDTELineDiagControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of DTE diagnostic control table."
INDEX { sdteIndex }
::= { sdteLineDiagControlTable 1 }
SDTELineDiagControl ::= SEQUENCE {
sdteLoopbacktype INTEGER,
sdteLoopbackstatus INTEGER
-- sdteBertctrl
-- INTEGER,
-- sdteBertstatus
-- INTEGER,
-- sdteElapseseconds
-- Counter,
-- sdteErrorseconds
-- Counter,
-- sdteErrorcounts
-- Counter
}
sdteLoopbacktype OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
loopback-To-DTE(2),
loopback-To-Line(3),
remoteV54-active(4),
remoteV54-deactive(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SDTE Loopback Type"
::= { sdteDiagCtrlEntry 2 }
sdteLoopbackstatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopback-not-active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SDTE Loopback Status"
::= { sdteDiagCtrlEntry 3 }
-- sdteBertctrl OBJECT-TYPE
-- SYNTAX INTEGER {
-- bert-DEACTIVE(1),
-- prbs-ACTIVE-DTE(2),
-- qrss-ACTIVE-DTE(3),
-- bert-RESET-ERROR-COUNT(4),
-- bert-INJECT-ERROR(5)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "SDTE PRBS/QRSS Control"
-- ::= { sdteDiagCtrlEntry 4 }
--
-- sdteBertstatus OBJECT-TYPE
-- SYNTAX INTEGER {
-- bert-SYNC(1),
-- bert-UNSYNC(2),
-- bert-NOT-ACTIVE(3)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "SDTE PRBS/QRSS Status"
-- ::= { sdteDiagCtrlEntry 5 }
--
-- sdteElapseseconds OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "sdte PRBS/QRSS Elapse Seconds"
-- ::= { sdteDiagCtrlEntry 6 }
--
-- sdteErrorseconds OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "sdte PRBS/QRSS Error Seconds"
-- ::= { sdteDiagCtrlEntry 7 }
--
-- sdteErrorcounts OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "sdte PRBS/QRSS Error Counts"
-- ::= { sdteDiagCtrlEntry 8 }
--
-- Command Control Table
--
sdteCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTECommandControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { sdte-card 6 }
sdteCommandCtrlEntry OBJECT-TYPE
SYNTAX SDTECommandControl
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { sdteIndex }
::= { sdteCommandControlTable 1 }
SDTECommandControl ::= SEQUENCE {
sdteAlarmQueueReset INTEGER,
sdteAlarmHistoryReset INTEGER,
sdtePortReset INTEGER,
sdtePortLoadDefault INTEGER
}
sdteAlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { sdteCommandCtrlEntry 2 }
sdteAlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { sdteCommandCtrlEntry 3 }
sdtePortReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset SDTE Port"
::= { sdteCommandCtrlEntry 4 }
sdtePortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
loadDefault(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default SDTE Port"
::= { sdteCommandCtrlEntry 5 }
--
-- SYSTEM Information Table
--
sdteSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTESystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { sdte-card 7 }
sdteSystemInfoEntry OBJECT-TYPE
SYNTAX SDTESystemInformation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { sdteIndex }
::= { sdteSystemInformationTable 1 }
SDTESystemInformation ::= SEQUENCE {
sdtePromVersion DisplayString
}
sdtePromVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE EPROM Version"
::= { sdteSystemInfoEntry 2 }
--
-- SDTE Status Table
--
sdteStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SDTEStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SDTE status table."
::= { sdte-card 8 }
sdteStatusEntry OBJECT-TYPE
SYNTAX SDTEStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the SDTE status table."
INDEX { sdteIndex }
::= { sdteStatusTable 1 }
SDTEStatus ::= SEQUENCE {
sdteStatusRTS INTEGER,
sdteStatusCTS INTEGER,
sdteStatusDSR INTEGER,
sdteStatusDCD INTEGER,
sdteExtclkloss INTEGER
}
sdteStatusRTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE RTS status "
::= { sdteStatusEntry 2 }
sdteStatusCTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE CTS status "
::= { sdteStatusEntry 3 }
sdteStatusDSR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE DSR status "
::= { sdteStatusEntry 4 }
sdteStatusDCD OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE DCD status "
::= { sdteStatusEntry 5 }
sdteExtclkloss OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
loss(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SDTE external clock loss "
::= { sdteStatusEntry 6 }
sdteTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of SDTE"
::= { sdte-card 100 }
--=====================================================================--
-- TDMOE card MIB
--=====================================================================--
tdmoeConfigTable OBJECT IDENTIFIER ::= { tdmoe-card 1 }
miscellaneousConfig OBJECT-TYPE
SYNTAX SEQUENCE OF MiscellaneousConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Miscellaneous Config Table."
::= { tdmoeConfigTable 1 }
miscellaneousConfigEntry OBJECT-TYPE
SYNTAX MiscellaneousConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Advanced Config Entry"
INDEX { tdmoeSlotIndex }
::= { miscellaneousConfig 1 }
MiscellaneousConfigEntry ::= SEQUENCE {
tdmoeSlotIndex LargeSlotIndex,
tdmoeActiveBundleTimer INTEGER,
tdmoeAlarmFilter INTEGER,
tdmoeDelaySwitch INTEGER,
tdmoeRecoverDelay INTEGER
}
tdmoeSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { miscellaneousConfigEntry 1 }
tdmoeActiveBundleTimer OBJECT-TYPE
SYNTAX INTEGER (1..99999999 )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"arp timer range: 1~9999999 seconds"
::= { miscellaneousConfigEntry 2 }
tdmoeAlarmFilter OBJECT-TYPE
SYNTAX INTEGER (0..180)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protection: Alarm Filter: 0~180 seconds"
::= { miscellaneousConfigEntry 3 }
tdmoeDelaySwitch OBJECT-TYPE
SYNTAX INTEGER (0..180)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protection: Delay Switch: 0~180 seconds"
::= { miscellaneousConfigEntry 4 }
tdmoeRecoverDelay OBJECT-TYPE
SYNTAX INTEGER (0..180)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protection: Recover Delay: 0~180 seconds"
::= { miscellaneousConfigEntry 5 }
--
--Qos Table
--
qosConfig OBJECT IDENTIFIER ::= { tdmoeConfigTable 2}
qosClassOfServiceConfig OBJECT IDENTIFIER ::= { qosConfig 1 }
priorityModeConfig OBJECT-TYPE
SYNTAX SEQUENCE OF PriorityModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Priority Mode Table."
::= { qosClassOfServiceConfig 1 }
priorityModeEntry OBJECT-TYPE
SYNTAX PriorityModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Priority Mode Table."
INDEX { priorityModeSlotIndex , priorityModePortIndex }
::= { priorityModeConfig 1 }
PriorityModeEntry ::= SEQUENCE {
priorityModeSlotIndex LargeSlotIndex,
priorityModePortIndex EthportIndex,
priorityModeMode INTEGER
}
priorityModeSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { priorityModeEntry 1 }
priorityModePortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SWPortNum:switch port SNMP, WAN1, WAN2, and LAN."
::= { priorityModeEntry 2 }
priorityModeMode OBJECT-TYPE
SYNTAX INTEGER {
fixed(1),
cos(2),
tos(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN1 Priority Mode"
::= { priorityModeEntry 3 }
--
-- FixedPriorityTable
--
fixedPriorityConfig OBJECT-TYPE
SYNTAX SEQUENCE OF FixedPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Fixed Priority Table."
::= { qosClassOfServiceConfig 2 }
fixedPriorityEntry OBJECT-TYPE
SYNTAX FixedPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Fixed Priority Table."
INDEX { fixSlotIndex , fixPortIndex }
::= { fixedPriorityConfig 1 }
FixedPriorityEntry ::= SEQUENCE {
fixSlotIndex LargeSlotIndex,
fixPortIndex EthportIndex,
fixTransmitPriority INTEGER
}
fixSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { fixedPriorityEntry 1 }
fixPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"priority port."
::= { fixedPriorityEntry 2 }
fixTransmitPriority OBJECT-TYPE
SYNTAX INTEGER {
priority-0(1),
priority-1(2),
priority-2(3),
priority-3(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transmit Priority"
::= { fixedPriorityEntry 3 }
--
-- VlanCosPriorityTable
--
vlanCosPriorityConfig OBJECT-TYPE
SYNTAX SEQUENCE OF VlanCosPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS VLAN Cos Priority Table."
::= { qosClassOfServiceConfig 3 }
vlanCosPriorityEntry OBJECT-TYPE
SYNTAX VlanCosPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS VLAN Cos Priority Table."
INDEX { cosSlotIndex , cosCosPriority }
::= { vlanCosPriorityConfig 1 }
VlanCosPriorityEntry ::= SEQUENCE {
cosSlotIndex LargeSlotIndex,
cosCosPriority INTEGER,
cosTransmitPriority INTEGER
}
cosSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { vlanCosPriorityEntry 1 }
cosCosPriority OBJECT-TYPE
SYNTAX INTEGER {
cos-priority-0(1),
cos-priority-1(2),
cos-priority-2(3),
cos-priority-3(4),
cos-priority-4(5),
cos-priority-5(6),
cos-priority-6(7),
cos-priority-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Vlan Cos Priority 0 to 7"
::= { vlanCosPriorityEntry 2 }
cosTransmitPriority OBJECT-TYPE
SYNTAX INTEGER {
priority-0(1),
priority-1(2),
priority-2(3),
priority-3(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transmit Priority"
::= { vlanCosPriorityEntry 3 }
--
-- TosPriorityTable
--
tosPriorityConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TosPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Tos Priority Table."
::= { qosClassOfServiceConfig 4 }
tosPriorityEntry OBJECT-TYPE
SYNTAX TosPriorityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Tos Priority Table."
INDEX { tosSlotIndex , tosTosPriority }
::= { tosPriorityConfig 1 }
TosPriorityEntry ::= SEQUENCE {
tosSlotIndex LargeSlotIndex,
tosTosPriority INTEGER,
tosTransmitPriority INTEGER
}
tosSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tosPriorityEntry 1 }
tosTosPriority OBJECT-TYPE
SYNTAX INTEGER {
tos-priority-0(1),
tos-priority-1(2),
tos-priority-2(3),
tos-priority-3(4),
tos-priority-4(5),
tos-priority-5(6),
tos-priority-6(7),
tos-priority-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tos Priority 0 to 7"
::= { tosPriorityEntry 2 }
tosTransmitPriority OBJECT-TYPE
SYNTAX INTEGER {
priority-0(1),
priority-1(2),
priority-2(3),
priority-3(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transmit Priority"
::= { tosPriorityEntry 3 }
--=====================
-- Qos Tx Schedule Table
--=====================
qosTxScheduleConfig OBJECT IDENTIFIER ::= { qosConfig 2 }
scheduleAlgorithmConfig OBJECT-TYPE
SYNTAX SEQUENCE OF ScheduleAlgorithmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Scheduling Algorithm Table."
::= { qosTxScheduleConfig 1 }
scheduleAlgorithmEntry OBJECT-TYPE
SYNTAX ScheduleAlgorithmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Scheduling Algorithm Table."
INDEX { scheduleSlotIndex , schedulePortIndex }
::= { scheduleAlgorithmConfig 1 }
ScheduleAlgorithmEntry ::= SEQUENCE {
scheduleSlotIndex LargeSlotIndex,
schedulePortIndex EthportIndex,
scheduleAlgorithm INTEGER
}
scheduleSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { scheduleAlgorithmEntry 1 }
schedulePortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"scheduling algorithm port"
::= { scheduleAlgorithmEntry 2 }
scheduleAlgorithm OBJECT-TYPE
SYNTAX INTEGER {
strict-priority(1),
weighted-round-robin(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"scheduling algorithm"
::= { scheduleAlgorithmEntry 3 }
--
-- WRR Weight Table
--
wrrWeightConfig OBJECT-TYPE
SYNTAX SEQUENCE OF WrrweightEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Scheduling Algorithm Table."
::= { qosTxScheduleConfig 2 }
wrrweightEntry OBJECT-TYPE
SYNTAX WrrweightEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Wrr Table."
INDEX { wrrSlotIndex }
::= { wrrWeightConfig 1 }
WrrweightEntry ::= SEQUENCE {
wrrSlotIndex LargeSlotIndex,
wrrWeightP0Queue INTEGER,
wrrWeightP1Queue INTEGER,
wrrWeightP2Queue INTEGER,
wrrWeightP3Queue INTEGER
}
wrrSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { wrrweightEntry 1 }
wrrWeightP0Queue OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"P0 Queue Percentage, sum of Queue percentage of the four ports must be 100% "
::= { wrrweightEntry 2 }
wrrWeightP1Queue OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"P1 Queue Percentage"
::= { wrrweightEntry 3}
wrrWeightP2Queue OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"P2 Queue Percentage"
::= { wrrweightEntry 4}
wrrWeightP3Queue OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"P3 Queue Percentage"
::= { wrrweightEntry 5}
-- flow control
flowControlConfig OBJECT-TYPE
SYNTAX SEQUENCE OF FlowControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS flow control Table."
::= { qosTxScheduleConfig 3 }
flowControlEntry OBJECT-TYPE
SYNTAX FlowControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS flow control Table."
INDEX { flowSlotIndex , flowPortIndx }
::= { flowControlConfig 1 }
FlowControlEntry ::= SEQUENCE {
flowSlotIndex LargeSlotIndex,
flowPortIndx EthportIndex,
flowFlowControl INTEGER
}
flowSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { flowControlEntry 1 }
flowPortIndx OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE port 1-4"
::= { flowControlEntry 2 }
flowFlowControl OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"flow control"
::= { flowControlEntry 3 }
qosRateCtrlConfig OBJECT-TYPE
SYNTAX SEQUENCE OF RateCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Ethernet QoS Scheduling Algorithm Table."
::= { qosConfig 3}
rateCtrlEntry OBJECT-TYPE
SYNTAX RateCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Ethernet QoS Wrr Table."
INDEX { rateCtrlSlotIndex , rateCtrlPortIndex }
::= { qosRateCtrlConfig 1 }
RateCtrlEntry ::= SEQUENCE {
rateCtrlSlotIndex LargeSlotIndex,
rateCtrlPortIndex EthportIndex,
rateCtrlSpeedRangeValue INTEGER,
rateCtrlRateGranularity INTEGER
}
rateCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rateCtrlEntry 1 }
rateCtrlPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Index"
::= { rateCtrlEntry 2 }
rateCtrlSpeedRangeValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"64kbps to 1mbps in the ratelimit mode of 64kbps, 1mbps to 100mbps in
the ratelimit mode of 1 mbp, and 100 mbps to 1000 mbps in the ratelimit mode of 10 mbps. "
::= { rateCtrlEntry 3 }
rateCtrlRateGranularity OBJECT-TYPE
SYNTAX INTEGER {
kbps-64(1),
mbps-1(2),
mbps-10(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port rate limit: from 64kbps to 1mbps in increments of of 64kbps, from 1mbps to 100mbps in
increments of 1 mbp and from 100 mbps to 1000 mbps in increments of 10 mbps."
::= { rateCtrlEntry 4 }
--
-- eth phy config table
--
ethPortConfig OBJECT IDENTIFIER ::= { tdmoeConfigTable 3}
ethPortElectricConfig OBJECT-TYPE
SYNTAX SEQUENCE OF EthPortelectricEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth phy electric Config Table."
::= { ethPortConfig 1 }
ethPortelectricEntry OBJECT-TYPE
SYNTAX EthPortelectricEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { ethSlotIndex , ethPortIndex }
::= { ethPortElectricConfig 1 }
EthPortelectricEntry ::= SEQUENCE {
ethSlotIndex LargeSlotIndex,
ethPortIndex EthportIndex,
ethState INTEGER,
ethAutoNegotiation INTEGER,
ethSpeed INTEGER,
ethDuplex INTEGER
}
ethSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ethPortelectricEntry 1 }
ethPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"eth port 1-4"
::= { ethPortelectricEntry 2 }
ethState OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port State"
::= { ethPortelectricEntry 3 }
ethAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"auto negotiation state"
::= {ethPortelectricEntry 4 }
ethSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbps-10 (1),
mbps-100 (2),
mbps-1000 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port speed 10/100/1000 mbps"
::= {ethPortelectricEntry 5 }
ethDuplex OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port duplex mode(half/full)"
::= {ethPortelectricEntry 6 }
ethPortOpticalConfig OBJECT-TYPE
SYNTAX SEQUENCE OF EthPortopticalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth phy electric Config Table."
::= { ethPortConfig 2 }
ethPortopticalEntry OBJECT-TYPE
SYNTAX EthPortopticalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { ethopticalSlotIndex , ethopticalPortIndex }
::= { ethPortOpticalConfig 1 }
EthPortopticalEntry ::= SEQUENCE {
ethopticalSlotIndex LargeSlotIndex,
ethopticalPortIndex INTEGER,
ethopticalState INTEGER,
ethopticalAutolaserShutdown INTEGER,
ethopticalSpeed INTEGER,
ethopticalAutoNegotiation INTEGER,
ethopticalDuplex INTEGER,
ethopticalPulseRepetitionTime INTEGER,
ethopticalManualRestart INTEGER
}
ethopticalSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ethPortopticalEntry 1 }
ethopticalPortIndex OBJECT-TYPE
SYNTAX INTEGER {
eth-1 (1),
eth-2 (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"eth port 1-2"
::= { ethPortopticalEntry 2 }
ethopticalState OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port State"
::= { ethPortopticalEntry 3 }
ethopticalAutolaserShutdown OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"autolasershutdown state"
::= {ethPortopticalEntry 4 }
ethopticalSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbps-1000 (1),
mbps-100 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"port State"
::= { ethPortopticalEntry 5 }
ethopticalAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"auto negotiation state"
::= {ethPortopticalEntry 6 }
ethopticalDuplex OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port duplex mode(half/full)"
::= {ethPortopticalEntry 7 }
ethopticalPulseRepetitionTime OBJECT-TYPE
SYNTAX INTEGER (60..300)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ALS/APSD pulse repetition time for automatic restart(sec)"
::= { ethPortopticalEntry 8 }
ethopticalManualRestart OBJECT-TYPE
SYNTAX INTEGER {
off(1),
start(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Optical port manual restart"
::= { ethPortopticalEntry 9 }
--
-- ethL2 Table
--
ethSwitchConfig OBJECT IDENTIFIER ::= { tdmoeConfigTable 4 }
agingtimeConfig OBJECT-TYPE
SYNTAX SEQUENCE OF AgingtimeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { ethSwitchConfig 1 }
agingtimeEntry OBJECT-TYPE
SYNTAX AgingtimeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"age tme Entry."
INDEX { tdmoeSlotIndex }
::= { agingtimeConfig 1 }
AgingtimeEntry ::= SEQUENCE {
tdmoeAgingtime INTEGER
}
tdmoeAgingtime OBJECT-TYPE
SYNTAX INTEGER (0..3825)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac table aging time range: 0~3825 seconds, setting 0 second disables aging process
aging time must be a multiple of fifteen."
::= {agingtimeEntry 2 }
addMacConfig OBJECT-TYPE
SYNTAX SEQUENCE OF AddMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"add static mac table"
::= { ethSwitchConfig 2}
addMacEntry OBJECT-TYPE
SYNTAX AddMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"age static mac Entry."
INDEX { tdmoeSlotIndex }
::= { addMacConfig 1 }
AddMacEntry ::= SEQUENCE {
tdmoeAddPort INTEGER,
tdmoeAddmacAddress DisplayString
}
tdmoeAddPort OBJECT-TYPE
SYNTAX INTEGER {
mgt (1),
eth-1 (2),
eth-2 (3),
eth-3 (4),
eth-4 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"determine which port to add mac"
::= {addMacEntry 2}
tdmoeAddmacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"add static mac in hex mode(0~F)"
::= {addMacEntry 3}
delMacConfig OBJECT-TYPE
SYNTAX SEQUENCE OF DelMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"delete static mac table"
::= { ethSwitchConfig 3 }
delMacEntry OBJECT-TYPE
SYNTAX DelMacEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"delete static mac Entry."
INDEX { tdmoeSlotIndex }
::= { delMacConfig 1 }
DelMacEntry ::= SEQUENCE {
tdmoeDelPort INTEGER
}
tdmoeDelPort OBJECT-TYPE
SYNTAX INTEGER {
mgt (1),
eth-1 (2),
eth-2 (3),
eth-3 (4),
eth-4 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"delete port's mac"
::= {delMacEntry 2}
rstpTable OBJECT IDENTIFIER ::= {tdmoeConfigTable 5 }
rstpConfig OBJECT-TYPE
SYNTAX SEQUENCE OF RstpConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"rstp config table"
::= {rstpTable 1}
rstpConfigEntry OBJECT-TYPE
SYNTAX RstpConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"rstp Config Entry."
INDEX { rstpSlotIndex }
::= { rstpConfig 1 }
RstpConfigEntry ::= SEQUENCE {
rstpSlotIndex LargeSlotIndex,
rstpState INTEGER,
rstpPriority INTEGER,
rstpHellotime INTEGER,
rstpMaximumAge INTEGER,
rstpForwardDelay INTEGER
}
rstpSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rstpConfigEntry 1 }
rstpState OBJECT-TYPE
SYNTAX INTEGER {
off (1),
stp (2),
rstp (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp state"
::= {rstpConfigEntry 2}
rstpPriority OBJECT-TYPE
SYNTAX INTEGER (0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp priority 0~65534"
::= {rstpConfigEntry 3}
rstpHellotime OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp hello time 1~10 seconds"
::= {rstpConfigEntry 4}
rstpMaximumAge OBJECT-TYPE
SYNTAX INTEGER (6..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp maxumun age 6~40 seconds"
::= {rstpConfigEntry 5}
rstpForwardDelay OBJECT-TYPE
SYNTAX INTEGER (4..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp forward delay 4~30 seconds"
::= {rstpConfigEntry 6}
rstpPortConfig OBJECT-TYPE
SYNTAX SEQUENCE OF RstpPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= {rstpTable 2}
rstpPortConfigEntry OBJECT-TYPE
SYNTAX RstpPortConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"rstp Port Config Entry."
INDEX { rstpSlotIndex , rstpPortIndex }
::= { rstpPortConfig 1 }
RstpPortConfigEntry ::= SEQUENCE {
rstpPortIndex EthportIndex,
rstpStpState INTEGER,
rstpPortPriority INTEGER,
rstpPortCost INTEGER,
rstpLinkType INTEGER,
rstpEdgePort INTEGER
}
rstpPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Eth port 1-4"
::= { rstpPortConfigEntry 2}
rstpStpState OBJECT-TYPE
SYNTAX INTEGER{
disable (1),
block (2),
listen (3),
learn (4),
forward (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"stp port state"
::= {rstpPortConfigEntry 3}
rstpPortPriority OBJECT-TYPE
SYNTAX INTEGER (0..240)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp port priority 0~240"
::= {rstpPortConfigEntry 4}
rstpPortCost OBJECT-TYPE
SYNTAX INTEGER (0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp port cost 0~32767"
::= {rstpPortConfigEntry 5}
rstpLinkType OBJECT-TYPE
SYNTAX INTEGER {
auto (1),
p-to-p (2),
shared (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rstp port link type"
::= {rstpPortConfigEntry 6}
rstpEdgePort OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"edge port mode"
::= {rstpPortConfigEntry 7}
linkaggregateConfig OBJECT-TYPE
SYNTAX SEQUENCE OF AggregateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate config"
::= {tdmoeConfigTable 6}
aggregateEntry OBJECT-TYPE
SYNTAX AggregateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate Entry."
INDEX { aggreSlotIndex }
::= { linkaggregateConfig 1 }
AggregateEntry ::= SEQUENCE {
aggreSlotIndex LargeSlotIndex,
aggreTrunkGroup1 INTEGER,
aggreTrunkGroup2 INTEGER
}
aggreSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { aggregateEntry 1 }
aggreTrunkGroup1 OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
leader-ETH1 (2),
leader-ETH2 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"choose group1 port trunk leader(eth1/eth2)"
::= {aggregateEntry 2}
aggreTrunkGroup2 OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
leader-ETH3 (2),
leader-ETH4 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"choose group2 porttrunk leader(eth3/eth4)"
::= {aggregateEntry 3}
tributaryConfig OBJECT IDENTIFIER ::= { tdmoeConfigTable 7 }
tributaryModeConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TributaryModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"tributary config table"
::= {tributaryConfig 1 }
tributaryModeEntry OBJECT-TYPE
SYNTAX TributaryModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"tributary Entry."
INDEX { tribSlotIndex }
::= { tributaryModeConfig 1 }
TributaryModeEntry ::= SEQUENCE {
tribSlotIndex LargeSlotIndex,
tribMode INTEGER
}
tribSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tributaryModeEntry 1 }
tribMode OBJECT-TYPE
SYNTAX INTEGER{
e1(1),
t1(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"transport mode:E1/T1"
::= {tributaryModeEntry 2}
tributaryPortConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TributaryPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"tributary config table"
::= {tributaryConfig 2 }
tributaryPortEntry OBJECT-TYPE
SYNTAX TributaryPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"tributary Entry."
INDEX { tribSlotIndex , tribTribIndex }
::= { tributaryPortConfig 1 }
TributaryPortEntry ::= SEQUENCE {
tribTribIndex Tributaryport,
tribFrame INTEGER,
tribCAS INTEGER,
tribRemoteloss INTEGER
}
tribTribIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"trib port 1-4"
::= { tributaryPortEntry 2}
tribFrame OBJECT-TYPE
SYNTAX INTEGER{
e1-fas (1),
e1-unframe (2),
t1-t1403(3),
t1-esf (4),
t1-d4 (5),
t1-unframe (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"e1/t1 line frame"
::= {tributaryPortEntry 3}
tribCAS OBJECT-TYPE
SYNTAX INTEGER{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"cas state"
::= {tributaryPortEntry 4}
tribRemoteloss OBJECT-TYPE
SYNTAX INTEGER{
continue-send-packet (1),
stop (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"when remote side are lost, local side stop or continue sending data."
::= {tributaryPortEntry 5}
toeBundleProtectionConfig OBJECT-TYPE
SYNTAX SEQUENCE OF ToeBundleProtectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate config"
::= {tdmoeConfigTable 8}
toeBundleProtectionEntry OBJECT-TYPE
SYNTAX ToeBundleProtectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate Entry."
INDEX { toeBPSlot }
::= { toeBundleProtectionConfig 1 }
ToeBundleProtectionEntry ::= SEQUENCE {
toeBPSlot LargeSlotIndex,
toeBPEnable INTEGER,
toeBPTimeout INTEGER
}
toeBPSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { toeBundleProtectionEntry 1 }
toeBPEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"choose group1 port trunk leader(eth1/eth2)"
::= {toeBundleProtectionEntry 2}
toeBPTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"choose group2 porttrunk leader(eth3/eth4)"
::= {toeBundleProtectionEntry 3}
-- Synce Config Table --
-- toeSynceGroup OBJECT IDENTIFIER ::= { tdmoeConfigTable 9 }
-- toeTimingGeneralTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ToeTimingGeneralEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "SyncE config table"
-- ::= {toeSynceGroup 1 }
-- toeTimingGeneralEntry OBJECT-TYPE
-- SYNTAX ToeTimingGeneralEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "SyncE Entry."
-- INDEX { toeTimingSlotIndex }
-- ::= { toeTimingGeneralTable 1 }
-- ToeTimingGeneralEntry ::= SEQUENCE {
-- toeTimingSlotIndex LargeSlotIndex,
-- toeTimingSsmMode INTEGER,
-- toeTimingWtrTimer Integer32,
-- toeTimingQLOption INTEGER
-- }
-- toeTimingSlotIndex OBJECT-TYPE
-- SYNTAX LargeSlotIndex
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot 1~12, total 12 slots."
-- ::= { toeTimingGeneralEntry 1 }
-- toeTimingSsmMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- EsmcSsmDisabled(1),
-- EsmcSsmEnabled(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Timing mode"
-- ::= { toeTimingGeneralEntry 2 }
-- toeTimingWtrTimer OBJECT-TYPE
-- SYNTAX Integer32 (1..15)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Timing wait-to-restore timer period"
-- ::= { toeTimingGeneralEntry 3 }
-- toeTimingQLOption OBJECT-TYPE
-- SYNTAX INTEGER {
-- g781Option1(1),
-- g781Option2(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Synchronous ESMC option"
-- ::= { toeTimingGeneralEntry 4 }
-- toeTimingSourceAddDelTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ToeTimingSourceAddDelEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "This table is used to configure Timing interfaces"
-- ::= { toeSynceGroup 2 }
-- toeTimingSourceAddDelEntry OBJECT-TYPE
-- SYNTAX ToeTimingSourceAddDelEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "The entry of timingQLInterfaceTable."
-- INDEX { toeTimingSourceSlotIndex , toeTimingSourceIntfName }
-- ::= { toeTimingSourceAddDelTable 1 }
-- ToeTimingSourceAddDelEntry ::= SEQUENCE {
-- toeTimingSourceSlotIndex LargeSlotIndex,
-- toeTimingSourceIntfName INTEGER,
-- toeTimingSourcePriority INTEGER,
-- toeTimingSourceStatus INTEGER
-- }
-- toeTimingSourceSlotIndex OBJECT-TYPE
-- SYNTAX LargeSlotIndex
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot 1~12, total 12 slots."
-- ::= { toeTimingSourceAddDelEntry 1 }
-- toeTimingSourceIntfName OBJECT-TYPE
-- SYNTAX INTEGER {
-- internal(1),
-- eth1(2),
-- eth2(3),
-- eth3(4),
-- eth4(5)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The interface name for Timing source add/delete action."
-- ::= { toeTimingSourceAddDelEntry 2 }
-- toeTimingSourcePriority OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Clock priority for Timing source add/delete action"
-- ::= { toeTimingSourceAddDelEntry 3 }
-- toeTimingSourceStatus OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(1),
-- enable(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The status of source to/from the Timing source list."
-- ::= { toeTimingSourceAddDelEntry 4 }
-- toeTimingCurrentTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ToeTimingCurrentEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "This table is used to disply timing current information"
-- ::= { toeSynceGroup 3 }
-- toeTimingCurrentEntry OBJECT-TYPE
-- SYNTAX ToeTimingCurrentEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "SyncE Entry."
-- INDEX { toeTimingCurrentSlotIndex }
-- ::= { toeTimingCurrentTable 1 }
-- ToeTimingCurrentEntry ::= SEQUENCE {
-- toeTimingCurrentSlotIndex LargeSlotIndex,
-- toeTimingCurrentClockLocked INTEGER,
-- toeTimingCurrentQL INTEGER
-- }
-- toeTimingCurrentSlotIndex OBJECT-TYPE
-- SYNTAX LargeSlotIndex
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot 1~12, total 12 slots."
-- ::= { toeTimingCurrentEntry 1 }
-- toeTimingCurrentClockLocked OBJECT-TYPE
-- SYNTAX INTEGER {
-- internal(1),
-- eth1(2),
-- eth2(3),
-- eth3(4),
-- eth4(5)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current clock selected for Timing"
-- ::= { toeTimingCurrentEntry 2 }
-- toeTimingCurrentQL OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- forceOpt1Prc(1),
-- forceOpt1SsuA(2),
-- forceOpt1SsuB(3),
-- forceOpt1Eec1(4),
-- forceOpt1Dnu(5),
-- forceOpt2Prs(6),
-- forceOpt2Stu(7),
-- forceOpt2St2(8),
-- forceOpt2Tnc(9),
-- forceOpt2St3(10),
-- forcePpt2Smc(11),
-- forceOpt2St4(12),
-- forceOpt2Prov(13),
-- forceOpt2Dus(14),
-- failed(15)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current QL(quality-level) selected for Timing"
-- ::= { toeTimingCurrentEntry 3 }
-- toeTimingNominatedSrcTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ToeTimingNominatedSrcEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "This table is used to show all Timing nominated clock source"
-- ::= { toeSynceGroup 4 }
-- toeTimingNominatedSrcEntry OBJECT-TYPE
-- SYNTAX ToeTimingNominatedSrcEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "The entry of timingNominatedSrcTable"
-- INDEX { toeTimingNominatedSlotIndex , toeTimingNominatedName }
-- ::= { toeTimingNominatedSrcTable 1 }
-- ToeTimingNominatedSrcEntry ::= SEQUENCE {
-- toeTimingNominatedSlotIndex INTEGER,
-- toeTimingNominatedName INTEGER,
-- toeTimingNominatedPriority INTEGER,
-- toeTimingNominatedQlIn INTEGER,
-- toeTimingNominatedSignalFail INTEGER,
-- toeTimingNominatedState INTEGER
-- }
-- toeTimingNominatedSlotIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Timing interface index"
-- ::= { toeTimingNominatedSrcEntry 1 }
-- toeTimingNominatedName OBJECT-TYPE
-- SYNTAX INTEGER {
-- internal(1),
-- eth1(2),
-- eth2(3),
-- eth3(4),
-- eth4(5)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Timing interface name"
-- ::= { toeTimingNominatedSrcEntry 2 }
-- toeTimingNominatedPriority OBJECT-TYPE
-- SYNTAX INTEGER (1..255)
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Priority of nominated clock source"
-- ::= { toeTimingNominatedSrcEntry 3 }
-- toeTimingNominatedQlIn OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- qlOpt1Prc(1),
-- qlOpt1SsuA(2),
-- qlOpt1SsuB(3),
-- qlOpt1Eec1(4),
-- qlOpt1Dnu(5),
-- qlOpt2Prs(6),
-- qlOpt2Stu(7),
-- qlOpt2St2(8),
-- qlOpt2Tnc(9),
-- qlOpt2St3(10),
-- qlOpt2Smc(11),
-- qlOpt2St4(12),
-- qlOpt2Prov(13),
-- qlOpt2Dus(14),
-- qlFailed(15)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current QL(quality-level) status of nominated clock source"
-- ::= { toeTimingNominatedSrcEntry 4 }
-- toeTimingNominatedSignalFail OBJECT-TYPE
-- SYNTAX INTEGER {
-- no(1),
-- yes(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current signal fail status of nominated clock source"
-- ::= { toeTimingNominatedSrcEntry 5 }
-- toeTimingNominatedState OBJECT-TYPE
-- SYNTAX INTEGER {
-- normal(1),
-- failed(2),
-- waitToRestore(3)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current state of nominated clock source"
-- ::= { toeTimingNominatedSrcEntry 6 }
-- toeTimingQLInterfaceTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF ToeTimingInterfaceEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "This table is used to configure Timing interfaces"
-- ::= { toeSynceGroup 5 }
-- toeTimingInterfaceEntry OBJECT-TYPE
-- SYNTAX ToeTimingInterfaceEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "The entry of timingQLInterfaceTable."
-- INDEX { toeTimingInterfaceSlotIndex , toeTimingInterfaceName }
-- ::= { toeTimingQLInterfaceTable 1 }
-- ToeTimingInterfaceEntry ::= SEQUENCE {
-- toeTimingInterfaceSlotIndex INTEGER,
-- toeTimingInterfaceName INTEGER,
-- toeTimingInterfaceSsm INTEGER,
-- toeTimingInterfaceRxQlMode INTEGER,
-- toeTimingInterfaceRxQl INTEGER,
-- toeTimingInterfaceTxQlMode INTEGER,
-- toeTimingInterfaceTxQl INTEGER
-- }
-- toeTimingInterfaceSlotIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Timing interface index"
-- ::= { toeTimingInterfaceEntry 1 }
-- toeTimingInterfaceName OBJECT-TYPE
-- SYNTAX INTEGER {
-- internal(1),
-- eth1(2),
-- eth2(3),
-- eth3(4),
-- eth4(5)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Timing interface name"
-- ::= { toeTimingInterfaceEntry 2 }
-- toeTimingInterfaceSsm OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(1),
-- enable(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Interface SSM transmit/receive config"
-- ::= { toeTimingInterfaceEntry 3 }
-- toeTimingInterfaceRxQlMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- forceOpt1Prc(1),
-- forceOpt1SsuA(2),
-- forceOpt1SsuB(3),
-- forceOpt1Eec1(4),
-- forceOpt1Dnu(5),
-- forceOpt2Prs(6),
-- forceOpt2Stu(7),
-- forceOpt2St2(8),
-- forceOpt2Tnc(9),
-- forceOpt2St3(10),
-- forceOpt2Smc(11),
-- forceOpt2St4(12),
-- forceOpt2Prov(13),
-- forceOpt2Dus(14)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Interface Rx QL mode setup"
-- ::= { toeTimingInterfaceEntry 4 }
-- toeTimingInterfaceRxQl OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- forceOpt1Prc(1),
-- forceOpt1SsuA(2),
-- forceOpt1SsuB(3),
-- forceOpt1Eec1(4),
-- forceOpt1Dnu(5),
-- forceOpt2Prs(6),
-- forceOpt2Stu(7),
-- forceOpt2St2(8),
-- forceOpt2Tnc(9),
-- forceOpt2St3(10),
-- forceOpt2Smc(11),
-- forceOpt2St4(12),
-- forceOpt2Prov(13),
-- forceOpt2Dus(14),
-- failed(15)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Interface Rx QL current status"
-- ::= { toeTimingInterfaceEntry 5 }
-- toeTimingInterfaceTxQlMode OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- forceOpt1Prc(1),
-- forceOpt1SsuA(2),
-- forceOpt1SsuB(3),
-- forceOpt1Eec1(4),
-- forceOpt1Dnu(5),
-- forceOpt2Prs(6),
-- forceOpt2Stu(7),
-- forceOpt2St2(8),
-- forceOpt2Tnc(9),
-- forceOpt2St3(10),
-- forceOpt2Smc(11),
-- forceOpt2St4(12),
-- forceOpt2Prov(13),
-- forceOpt2Dus(14)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Interface Tx QL mode setup"
-- ::= { toeTimingInterfaceEntry 6 }
-- toeTimingInterfaceTxQl OBJECT-TYPE
-- SYNTAX INTEGER {
-- auto(0),
-- forceOpt1Prc(1),
-- forceOpt1SsuA(2),
-- forceOpt1SsuB(3),
-- forceOpt1Eec1(4),
-- forceOpt1Dnu(5),
-- forceOpt2Prs(6),
-- forceOpt2Stu(7),
-- forceOpt2St2(8),
-- forceOpt2Tnc(9),
-- forceOpt2St3(10),
-- forceOpt2Smc(11),
-- forceOpt2St4(12),
-- forceOpt2Prov(13),
-- forceOpt2Dus(14),
-- failed(15)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Interface Tx QL current status"
-- ::= { toeTimingInterfaceEntry 7 }
-- End of SyncE --
timeSlotIpAssignTable OBJECT IDENTIFIER ::= { tdmoe-card 2 }
bundleAllocationConfig OBJECT-TYPE
SYNTAX SEQUENCE OF BundleAllocationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Bundle Allocation table."
::= {timeSlotIpAssignTable 1 }
bundleAllocationEntry OBJECT-TYPE
SYNTAX BundleAllocationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Bundle Allocation table."
INDEX { tdmoeSlotIndex }
::= { bundleAllocationConfig 1 }
BundleAllocationEntry ::= SEQUENCE {
tdmoeBundleAllocationMode INTEGER
}
tdmoeBundleAllocationMode OBJECT-TYPE
SYNTAX INTEGER {
mode-16 (1),
mode-32 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mode16:trib1-16,trib2-16,trib3-16,trib4-16
mode32:trib1-32,trib2-disable,trib3-32,trib4-disable"
::= { bundleAllocationEntry 2 }
timeSlotAssignConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TimeSlotAssignEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMOE bundle timeslot map table."
::= {timeSlotIpAssignTable 2 }
timeSlotAssignEntry OBJECT-TYPE
SYNTAX TimeSlotAssignEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"bundletimeSlot map Entry."
INDEX { timeSlotSlotIndex , timeSlotTribIndex , timeSlotTsIndex }
::= { timeSlotAssignConfig 1 }
TimeSlotAssignEntry ::= SEQUENCE {
timeSlotSlotIndex LargeSlotIndex,
timeSlotTribIndex Tributaryport,
timeSlotTsIndex INTEGER,
timeSlotBundleID Bundleid
}
timeSlotSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { timeSlotAssignEntry 1 }
timeSlotTribIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port index."
::= { timeSlotAssignEntry 2 }
timeSlotTsIndex OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { timeSlotAssignEntry 3 }
timeSlotBundleID OBJECT-TYPE
SYNTAX Bundleid
ACCESS read-write
STATUS mandatory
DESCRIPTION
"timeslot bundle index."
::= { timeSlotAssignEntry 4 }
bundleIPConfig OBJECT-TYPE
SYNTAX SEQUENCE OF BundleIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMOE bundle ip table."
::= { timeSlotIpAssignTable 3}
bundleIPEntry OBJECT-TYPE
SYNTAX BundleIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"timeSlotIP Entry."
INDEX { tdmoeSlotIndex }
::= { bundleIPConfig 1 }
BundleIPEntry ::= SEQUENCE {
tdmoeSrcIpAddress IpAddress,
tdmoeSubnetMask IpAddress,
tdmoeGatewayIpAddress IpAddress,
tdmoeSecSrcIpAddress IpAddress,
tdmoeSecSubnetMask IpAddress,
tdmoeSecGatewayIpAddress IpAddress,
toePriMacAddress DisplayString
}
tdmoeSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle Source IP Address"
::= { bundleIPEntry 2 }
tdmoeSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle Subnet Mask"
::= { bundleIPEntry 3 }
tdmoeGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle Gateway IP"
::= { bundleIPEntry 4 }
tdmoeSecSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary bundle Source IP Address"
::= { bundleIPEntry 5}
tdmoeSecSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary bundle Subnet Mask"
::= { bundleIPEntry 6 }
tdmoeSecGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary bundle Gateway IP"
::= { bundleIPEntry 7 }
toePriMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary mac address "
::= { bundleIPEntry 8}
-- Time Slot Ip Table
timeSlotIPConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TimeSlotIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMOE timeslot ip table."
::= { timeSlotIpAssignTable 4 }
timeSlotIPEntry OBJECT-TYPE
SYNTAX TimeSlotIPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"timeSlotIP Entry."
INDEX { tdmoeSlotIndex }
::= { timeSlotIPConfig 1 }
TimeSlotIPEntry ::= SEQUENCE {
tdmoePort INTEGER,
tdmoeBundleID Bundleid2,
tdmoeSrcUdpPortNumber INTEGER,
tdmoeFormat INTEGER,
tdmoeDestIPAddress IpAddress,
tdmoeTos INTEGER,
tdmoeStratum INTEGER,
tdmoeCellInBundle INTEGER,
tdmoeJitterTolerance INTEGER,
tdmoeJitterBuffer INTEGER,
tdmoeVLAN INTEGER,
tdmoeCVLANId INTEGER,
tdmoeCVLANPriority INTEGER,
tdmoeSVLANId INTEGER,
tdmoeSVLANPriority INTEGER,
tdmoeAction INTEGER,
tdmoeConfirm INTEGER,
toeBP INTEGER,
toeBPMS INTEGER,
toeBPMode INTEGER,
toeBPSecUdpPW INTEGER,
toeBPPriUdpHB INTEGER,
toeBPSecUdpHB INTEGER,
toeBPSecIP IpAddress,
toeBPCVLANId INTEGER,
toeBPCVLANPriority INTEGER,
toeBPSVLANId INTEGER,
toeBPSVLANPriority INTEGER,
toeBuType INTEGER,
tdmoeSrcEcid INTEGER,
toeMacAddress DisplayString
}
tdmoePort OBJECT-TYPE
SYNTAX INTEGER {
trib1(1),
trib2(2),
trib3(3),
trib4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port 1 to 4"
::= { timeSlotIPEntry 2 }
tdmoeBundleID OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { timeSlotIPEntry 3 }
tdmoeSrcUdpPortNumber OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UDP Number"
::= { timeSlotIPEntry 4}
tdmoeFormat OBJECT-TYPE
SYNTAX INTEGER {
aal1(1),
cesopsn(2),
satop(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"format"
::= { timeSlotIPEntry 5}
tdmoeDestIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address"
::= { timeSlotIPEntry 6}
tdmoeTos OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TOS Number"
::= { timeSlotIPEntry 7}
tdmoeStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Stratum Setup"
::= { timeSlotIPEntry 8}
tdmoeCellInBundle OBJECT-TYPE
SYNTAX INTEGER (1..1600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Cell In Bundle"
::= { timeSlotIPEntry 9}
tdmoeJitterTolerance OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Jitter Delay"
::= { timeSlotIPEntry 10}
tdmoeJitterBuffer OBJECT-TYPE
SYNTAX INTEGER (1..512)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Jitter Size"
::= { timeSlotIPEntry 11}
tdmoeVLAN OBJECT-TYPE
SYNTAX INTEGER {
off(1),
cvlan(2),
svlan(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VLAN switch"
::= { timeSlotIPEntry 12}
tdmoeCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { timeSlotIPEntry 13}
tdmoeCVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { timeSlotIPEntry 14}
tdmoeSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { timeSlotIPEntry 15}
tdmoeSVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { timeSlotIPEntry 16}
tdmoeAction OBJECT-TYPE
SYNTAX INTEGER {
add-bundle(1),
delete-bundle(2),
delete-all(3),
active-all(4),
change-bundle(5),
stop-Tx-bundle(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle action"
::= { timeSlotIPEntry 17}
tdmoeConfirm OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Confirm Setup"
::= { timeSlotIPEntry 18}
toeBP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle protection enable"
::= { timeSlotIPEntry 19}
toeBPMS OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Master or Slave"
::= { timeSlotIPEntry 20}
toeBPMode OBJECT-TYPE
SYNTAX INTEGER {
non-Revertible(1),
revertible(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Revertible"
::= { timeSlotIPEntry 21}
toeBPSecUdpPW OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary PW UDP port"
::= { timeSlotIPEntry 22}
toeBPPriUdpHB OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Primary HB UDP port"
::= { timeSlotIPEntry 23}
toeBPSecUdpHB OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secondary HB UDP port"
::= { timeSlotIPEntry 24}
toeBPSecIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secodary Destination IP"
::= { timeSlotIPEntry 25}
toeBPCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { timeSlotIPEntry 26}
toeBPCVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { timeSlotIPEntry 27}
toeBPSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { timeSlotIPEntry 28}
toeBPSVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { timeSlotIPEntry 29}
toeBuType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bu type"
::= { timeSlotIPEntry 30}
tdmoeSrcEcid OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ECID"
::= { timeSlotIPEntry 31}
toeMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mac address "
::= { timeSlotIPEntry 32}
toeBPControl OBJECT-TYPE
SYNTAX SEQUENCE OF ToeBPControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate config"
::= {timeSlotIpAssignTable 5}
toeBPControlEntry OBJECT-TYPE
SYNTAX ToeBPControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"link aggregate Entry."
INDEX { toeBPControlSlot }
::= { toeBPControl 1 }
ToeBPControlEntry ::= SEQUENCE {
toeBPControlSlot LargeSlotIndex,
toeBPControlport INTEGER,
toeBPControlbundle Bundleid2,
toeBPControlMode INTEGER,
toeBPControlconfirm INTEGER
}
toeBPControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { toeBPControlEntry 1 }
toeBPControlport OBJECT-TYPE
SYNTAX INTEGER {
trib1(1),
trib2(2),
trib3(3),
trib4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"force change trib"
::= {toeBPControlEntry 2}
toeBPControlbundle OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-write
STATUS mandatory
DESCRIPTION
"force change bundle"
::= {toeBPControlEntry 3}
toeBPControlMode OBJECT-TYPE
SYNTAX INTEGER {
unLock(1),
force-change(2),
lock-pri(3),
lock-sec(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"force change mode"
::= {toeBPControlEntry 4}
toeBPControlconfirm OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"force change confirm"
::= {toeBPControlEntry 5}
--
-- Alarm Control Table SYNTAX
--
tdmoeAlarmTable OBJECT IDENTIFIER ::= { tdmoe-card 3}
tdmoeAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { tdmoeAlarmTable 1 }
tdmoeAlarmControlEntry OBJECT-TYPE
SYNTAX TdmoeAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the alarm control table."
INDEX { tdmoeSlotIndex }
::= { tdmoeAlarmControlTable 1 }
TdmoeAlarmControlEntry ::= SEQUENCE {
tdmoeArp-Lost AlarmSeverity,
tdmoeRx-Lost AlarmSeverity,
tdmoeJit-Buf-Underrun AlarmSeverity,
tdmoeJit-Buf-Overrun AlarmSeverity,
tdmoeEthernet-Link AlarmSeverity,
tdmoeLossOfBundle AlarmSeverity,
tdmoeSFP-alarm AlarmSeverity,
tdmoeBP-alarm AlarmSeverity,
tdmoeL-bit-alm AlarmSeverity,
tdmoeR-bit-alm AlarmSeverity,
tdmoeSyncEClockSwitch-alm AlarmSeverity,
tdmoeIPConflictAlm AlarmSeverity
}
tdmoeArp-Lost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"arp-bundle alarm severity type"
::= { tdmoeAlarmControlEntry 2 }
tdmoeRx-Lost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"rx-lost means the received packet sequence number is not the same as expected sequence
number. rx-Lost-bundle alarm severity type"
::= { tdmoeAlarmControlEntry 3 }
tdmoeJit-Buf-Underrun OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Jit-Buf-Underrun means jitter buffer is empty. jitter buffer underrun-bundle alarm severity type"
::= { tdmoeAlarmControlEntry 4 }
tdmoeJit-Buf-Overrun OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Jit-Buf-Overrun means that jitter buffer is full and there is no room for
new data to enter. jitter buffer overrun-bundle alarm severity type"
::= { tdmoeAlarmControlEntry 5}
tdmoeEthernet-Link OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"jitter buffer overrun-bundle alarm severity type"
::= { tdmoeAlarmControlEntry 6}
tdmoeLossOfBundle OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Loss of bundle"
::= { tdmoeAlarmControlEntry 7 }
tdmoeSFP-alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SFP-alarm"
::= { tdmoeAlarmControlEntry 8 }
tdmoeBP-alarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle protection-alarm"
::= { tdmoeAlarmControlEntry 9 }
tdmoeL-bit-alm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle L bit alarm"
::= { tdmoeAlarmControlEntry 10 }
tdmoeR-bit-alm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"bundle R bit alarm"
::= { tdmoeAlarmControlEntry 11 }
tdmoeSyncEClockSwitch-alm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SyncE Clock Switch alarm"
::= { tdmoeAlarmControlEntry 12 }
tdmoeIPConflictAlm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ip Conflict Switch alarm"
::= { tdmoeAlarmControlEntry 13 }
--
-- Alarm Threshold Setup Table
--
tdmoeThresControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeThresControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { tdmoeAlarmTable 2}
tdmoeThresControlEntry OBJECT-TYPE
SYNTAX TdmoeThresControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the threshold control table."
INDEX { tdmoeSlotIndex }
::= { tdmoeThresControlTable 1 }
TdmoeThresControlEntry ::= SEQUENCE {
tdmoeThresArp-Lost INTEGER,
tdmoeThresRx-Lost INTEGER,
-- tdmoeThresCell-Lost INTEGER,
tdmoeThresJit-Buf-Underrun INTEGER,
tdmoeThresJit-Buf-Overrun INTEGER
}
tdmoeThresArp-Lost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold of arp-bundle. ARP-bundle is count of ARP loss for a boundle."
::= { tdmoeThresControlEntry 2 }
tdmoeThresRx-Lost OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold of ex-Lost-bundle. Rx-Lost is count for a boundle about ethernet Lost/ jump events Packets."
::= { tdmoeThresControlEntry 3 }
-- tdmoeThresCell-Lost OBJECT-TYPE
-- SYNTAX INTEGER (1..65535)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Threshold of cell-Lost-bundle. Cell-Lost is count for a boundle about Rx AAL1 Lost Cells."
-- ::= { tdmoeThresControlEntry 4 }
tdmoeThresJit-Buf-Underrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Threshold of underrun-bundle. Underrun is count of underrun events for a boundle."
::= { tdmoeThresControlEntry 4}
tdmoeThresJit-Buf-Overrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Threshold of overrun-bundle. Overrun is count of overrun events for a boundle."
::= { tdmoeThresControlEntry 5}
--
-- Alarm History Table
--
AlarmSubChannel ::= INTEGER {
bundle0(1),
bundle1(2),
bundle2(3),
bundle3(4),
bundle4(5),
bundle5(6),
bundle6(7),
bundle7(8),
bundle8(9),
bundle9(10),
bundle10(11),
bundle11(12),
bundle12(13),
bundle13(14),
bundle14(15),
bundle15(16),
bundle16(17),
bundle17(18),
bundle18(19),
bundle19(20),
bundle20(21),
bundle21(22),
bundle22(23),
bundle23(24),
bundle24(25),
bundle25(26),
bundle26(27),
bundle27(28),
bundle28(29),
bundle29(30),
bundle30(31),
bundle31(32),
none(33)
}
tdmoeAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { tdmoe-card 4}
tdmoeAlarmHistoryEntry OBJECT-TYPE
SYNTAX TdmoeAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { tdmoehisSlotIndex , tdmoehisTribIndex ,
tdmoehisAlarmSubchannel , tdmoehisAlarmHistoryIndex }
::= { tdmoeAlarmHistoryTable 1 }
TdmoeAlarmHistoryEntry ::= SEQUENCE {
tdmoehisSlotIndex LargeSlotIndex,
tdmoehisTribIndex Alarmtributaryport,
tdmoehisAlarmSubchannel AlarmSubChannel,
tdmoehisAlarmHistoryIndex INTEGER,
tdmoehisThreshold INTEGER,
tdmoehisCurrentState INTEGER,
tdmoehisCurrentCount INTEGER,
tdmoehisAlarm AlarmSeverity
}
tdmoehisSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeAlarmHistoryEntry 1 }
tdmoehisTribIndex OBJECT-TYPE
SYNTAX Alarmtributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE alarm portIndex"
::= { tdmoeAlarmHistoryEntry 2 }
tdmoehisAlarmSubchannel OBJECT-TYPE
SYNTAX AlarmSubChannel
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE alarm subchannel"
::= { tdmoeAlarmHistoryEntry 3}
tdmoehisAlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
arp-Lost(1),
rx-Lost(2),
lossOfBundle(3),
jit-buf-underrun(4),
jit-buf-overrun(5),
eth1-link-down(6),
eth2-link-down(7),
eth3-link-down(8),
eth4-link-down(9),
spf1-tx-power-high(10),
spf2-tx-power-high(11),
spf1-tx-power-low(12),
spf2-tx-power-low(13),
spf1-rx-power-high(14),
spf2-rx-power-high(15),
spf1-rx-power-low(16),
spf2-rx-power-low(17),
spf1-tx-bias-high(18),
spf2-tx-bias-high(19),
spf1-tx-bias-low(20),
spf2-tx-bias-low(21),
bp-pri-hb-lost(22),
bp-sec-hb-lost(23),
bundle-l-bit(26),
bundle-r-bit(27),
syncEClockSwitch(28),
ipConflict(29)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { tdmoeAlarmHistoryEntry 4}
tdmoehisThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold value"
::= { tdmoeAlarmHistoryEntry 5 }
tdmoehisCurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { tdmoeAlarmHistoryEntry 6 }
tdmoehisCurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { tdmoeAlarmHistoryEntry 7 }
tdmoehisAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { tdmoeAlarmHistoryEntry 8 }
--
-- Current Performance Table
--
tdmoePerformanceTable OBJECT IDENTIFIER ::= { tdmoe-card 5}
tdmoeCurrentPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Performance Table"
::= { tdmoePerformanceTable 1}
tdmoeCurrentPerfEntry OBJECT-TYPE
SYNTAX TdmoeCurrentPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { tdmoeSlotIndex , tdmoeTribIndex , tdmoeBundleIDIndex }
::= { tdmoeCurrentPerfTable 1 }
TdmoeCurrentPerfEntry ::= SEQUENCE {
tdmoeTribIndex Tributaryport,
tdmoeBundleIDIndex Bundleid2,
tdmoeCurrentRx-Lost INTEGER,
-- tdmoeCurrentCell-Lost INTEGER,
tdmoeCurrentJit-Buf-Underrun INTEGER,
tdmoeCurrentJit-Buf-Overrun INTEGER,
tdmoeCurr15MinTimeElapsed INTEGER,
tdmoeValid15MinInterval INTEGER,
tdmoeCurrentHBPriLost INTEGER,
tdmoeCurrentHBSecLost INTEGER
}
tdmoeTribIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE perf portIndex"
::= { tdmoeCurrentPerfEntry 2 }
tdmoeBundleIDIndex OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE bundle 1-32"
::= { tdmoeCurrentPerfEntry 3 }
tdmoeCurrentRx-Lost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Rx-Lost Counter. Rx-Lost is count for a boundle about ethernet Lost/ jump events Packets."
::= { tdmoeCurrentPerfEntry 4 }
-- tdmoeCurrentCell-Lost OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Current Cell-Lost Counter. Cell-Lost is count for a boundle about Rx AAL1 Lost Cells."
-- ::= { tdmoeCurrentPerfEntry 5 }
tdmoeCurrentJit-Buf-Underrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current J-UR Counter. Underrun is count of jitter buffer underrun events."
::= { tdmoeCurrentPerfEntry 5 }
tdmoeCurrentJit-Buf-Overrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current J-OR Counter. Overrun is count of jitter buffer overrun events."
::= { tdmoeCurrentPerfEntry 6 }
tdmoeCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { tdmoeCurrentPerfEntry 7}
tdmoeValid15MinInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { tdmoeCurrentPerfEntry 8}
tdmoeCurrentHBPriLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Heart Beating primary packet lost."
::= { tdmoeCurrentPerfEntry 9 }
tdmoeCurrentHBSecLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Heart Beating secondary packet lost"
::= { tdmoeCurrentPerfEntry 10 }
--
-- Interval Performance Table
--
tdmoeIntervalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval Performance Table"
::= { tdmoePerformanceTable 2 }
tdmoeIntervalPerfEntry OBJECT-TYPE
SYNTAX TdmoeIntervalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Interval performance entry"
INDEX { tdmoeSlotIndex , tdmoeTribIndex , tdmoeBundleIDIndex , tdmoeIntervalPerfNum }
::= { tdmoeIntervalPerfTable 1 }
TdmoeIntervalPerfEntry ::= SEQUENCE {
tdmoeIntervalPerfNum INTEGER ,
tdmoeIntervalRx-Lost INTEGER,
-- tdmoeIntervalCell-Lost INTEGER,
tdmoeIntervalJit-Buf-Underrun INTEGER,
tdmoeIntervalJit-Buf-Overrun INTEGER,
tdmoeIntervalHBPriLost INTEGER,
tdmoeIntervalHBSecLost INTEGER
}
tdmoeIntervalPerfNum OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { tdmoeIntervalPerfEntry 4 }
tdmoeIntervalRx-Lost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" interval rx-lost counter "
::= { tdmoeIntervalPerfEntry 5}
-- tdmoeIntervalCell-Lost OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " interval cell-lost counter"
-- ::= { tdmoeIntervalPerfEntry 6 }
tdmoeIntervalJit-Buf-Underrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer underrun Counter "
::= { tdmoeIntervalPerfEntry 6}
tdmoeIntervalJit-Buf-Overrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer overrun Counter "
::= { tdmoeIntervalPerfEntry 7}
tdmoeIntervalHBPriLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Primary Heart Beating lost Counter "
::= { tdmoeIntervalPerfEntry 8}
tdmoeIntervalHBSecLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Secondary Heart Beating lost Counter "
::= { tdmoeIntervalPerfEntry 9}
--
-- Total Performance Table
--
tdmoeTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Performance Table"
::= { tdmoePerformanceTable 3 }
tdmoeTotalPerfEntry OBJECT-TYPE
SYNTAX TdmoeTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { tdmoeSlotIndex , tdmoeTribIndex , tdmoeBundleIDIndex }
::= { tdmoeTotalPerfTable 1 }
TdmoeTotalPerfEntry ::= SEQUENCE {
tdmoeTotalRx-Lost INTEGER,
-- tdmoeTotalCell-Lost INTEGER,
tdmoeTotalJit-Buf-Underrun INTEGER,
tdmoeTotalJit-Buf-Overrun INTEGER,
tdmoeTotalHBPriLost INTEGER,
tdmoeTotalHBSecLost INTEGER
}
tdmoeTotalRx-Lost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Rx-lost Counter in current 24 hours"
::= { tdmoeTotalPerfEntry 4 }
-- tdmoeTotalCell-Lost OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " Cell-lost Counter in current 24 hours"
-- ::= { tdmoeTotalPerfEntry 5 }
tdmoeTotalJit-Buf-Underrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Jitter buffer underrun Counter in current 24 hours"
::= { tdmoeTotalPerfEntry 5}
tdmoeTotalJit-Buf-Overrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Jitter buffer overrun Counter in current 24 hours"
::= { tdmoeTotalPerfEntry 6}
tdmoeTotalHBPriLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Heart Beating Primary lost Counter in current 24 hours"
::= { tdmoeTotalPerfEntry 7}
tdmoeTotalHBSecLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Heart Beating Secondary lost Counter in current 24 hours"
::= { tdmoeTotalPerfEntry 8}
--
-- Seven Days Performance Table
--
tdmoeSevenDaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 Days Performance Table"
::= { tdmoePerformanceTable 4}
tdmoeSevenDaysPerfEntry OBJECT-TYPE
SYNTAX TdmoeSevenDaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"7 days performance table"
INDEX { tdmoeSlotIndex , tdmoeTribIndex , tdmoeBundleIDIndex ,
tdmoeDaysIndex }
::= { tdmoeSevenDaysPerfTable 1 }
TdmoeSevenDaysPerfEntry ::= SEQUENCE {
tdmoeDaysIndex INTEGER,
tdmoeDateStrIndex DisplayString,
tdmoeSevenDaysRx-Lost INTEGER,
-- tdmoeSevenDaysCell-Lost INTEGER,
tdmoeSevenDaysJit-Buf-Underrun INTEGER,
tdmoeSevenDaysJit-Buf-Overrun INTEGER,
tdmoeSevenDaysHBPriLost INTEGER,
tdmoeSevenDaysHBSecLost INTEGER
}
tdmoeDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { tdmoeSevenDaysPerfEntry 4 }
tdmoeDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { tdmoeSevenDaysPerfEntry 5 }
tdmoeSevenDaysRx-Lost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Rx-lost Counter in seven days"
::= { tdmoeSevenDaysPerfEntry 6}
-- tdmoeSevenDaysCell-Lost OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " Cell-lost Counter in seven days"
-- ::= { tdmoeSevenDaysPerfEntry 7 }
tdmoeSevenDaysJit-Buf-Underrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer underrun Counter in seven days"
::= { tdmoeSevenDaysPerfEntry 7}
tdmoeSevenDaysJit-Buf-Overrun OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" jitter buffer overrun Counter in seven days"
::= { tdmoeSevenDaysPerfEntry 8}
tdmoeSevenDaysHBPriLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Heart Beating Primary lost Counter in seven days"
::= { tdmoeSevenDaysPerfEntry 9}
tdmoeSevenDaysHBSecLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Heart Beating Secondary lost Counter in seven days"
::= { tdmoeSevenDaysPerfEntry 10}
-- Time Slot Ip Map Table
timeSlotIpMapTable OBJECT IDENTIFIER ::= { tdmoe-card 6}
bundleAllocationInfo OBJECT-TYPE
SYNTAX SEQUENCE OF BundleAllocationInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Ip Map table."
::= { timeSlotIpMapTable 1 }
bundleAllocationInfoEntry OBJECT-TYPE
SYNTAX BundleAllocationInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Time Slot Ip Map table."
INDEX { tdmoeMapSlotIndex }
::= { bundleAllocationInfo 1 }
BundleAllocationInfoEntry ::= SEQUENCE {
tdmoeMapSlotIndex LargeSlotIndex,
tdmoeMapBundleAllocationMode INTEGER
}
tdmoeMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { bundleAllocationInfoEntry 1 }
tdmoeMapBundleAllocationMode OBJECT-TYPE
SYNTAX INTEGER {
mode-16 (1),
mode-32 (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { bundleAllocationInfoEntry 2 }
timeSlotAssignInfo OBJECT-TYPE
SYNTAX SEQUENCE OF TimeSlotAssignInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Ip Map table."
::= { timeSlotIpMapTable 2 }
timeSlotAssignInfoEntry OBJECT-TYPE
SYNTAX TimeSlotAssignInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Time Slot Ip Map table."
INDEX { tdmoeMapSlotIndex , tdmoeMapTribIndex ,
tdmoeMapTsIndex }
::= { timeSlotAssignInfo 1 }
TimeSlotAssignInfoEntry ::= SEQUENCE {
tdmoeMapTribIndex Tributaryport,
tdmoeMapTsIndex INTEGER,
tdmoeMapBundleID Bundleid
}
tdmoeMapTribIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE portIndex"
::= { timeSlotAssignInfoEntry 2 }
tdmoeMapTsIndex OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { timeSlotAssignInfoEntry 3 }
tdmoeMapBundleID OBJECT-TYPE
SYNTAX Bundleid
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE bundle 0-31"
::= { timeSlotAssignInfoEntry 4 }
bundleIpinfo OBJECT-TYPE
SYNTAX SEQUENCE OF BundleIPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Ip Map table."
::= { timeSlotIpMapTable 3 }
bundleIPInfoEntry OBJECT-TYPE
SYNTAX BundleIPInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"timeSlotIP Entry."
INDEX { tdmoeBundleInfoSlotIndex }
::= { bundleIpinfo 1 }
BundleIPInfoEntry ::= SEQUENCE {
tdmoeBundleInfoSlotIndex LargeSlotIndex,
tdmoeBundleInfoSrcIpAddress IpAddress,
tdmoeBundleInfoSubnetMask IpAddress,
tdmoeBundleInfoGatewayIpAddress IpAddress,
tdmoeInfoSecSrcIpAddress IpAddress,
tdmoeInfoSecSubnetMask IpAddress,
tdmoeInfoSecGatewayIpAddress IpAddress,
toeInfoPriMacAddr DisplayString
}
tdmoeBundleInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { bundleIPInfoEntry 1 }
tdmoeBundleInfoSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Source IP Address"
::= { bundleIPInfoEntry 2 }
tdmoeBundleInfoSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Subnet Mask"
::= { bundleIPInfoEntry 3 }
tdmoeBundleInfoGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Gateway IP"
::= { bundleIPInfoEntry 4 }
tdmoeInfoSecSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Source IP Address"
::= { bundleIPInfoEntry 5 }
tdmoeInfoSecSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Subnet Mask"
::= { bundleIPInfoEntry 6 }
tdmoeInfoSecGatewayIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle Gateway IP"
::= { bundleIPInfoEntry 7 }
toeInfoPriMacAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary mac address "
::= { bundleIPInfoEntry 8}
timeSlotIpInfo OBJECT-TYPE
SYNTAX SEQUENCE OF TimeSlotIpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Time Slot Ip Map table."
::= { timeSlotIpMapTable 4 }
timeSlotIpInfoEntry OBJECT-TYPE
SYNTAX TimeSlotIpInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Time Slot Ip Map table."
INDEX { tdmoeMapSlotIndex , tdmoeMapTribIndex ,
tdmoeMapBundleIDIndex }
::= { timeSlotIpInfo 1 }
TimeSlotIpInfoEntry ::= SEQUENCE {
tdmoeMapBundleIDIndex Bundleid2,
tdmoeMapSrcUdpPortNumber INTEGER,
tdmoeMapFormat INTEGER,
tdmoeMapCellInBundle INTEGER,
tdmoeMapJit-Tolerance INTEGER,
tdmoeMapJit-Buffer INTEGER,
tdmoeMapDestIPAddress DisplayString,
tdmoeMapTos INTEGER,
tdmoeMapStratum INTEGER,
tdmoeMapVLAN INTEGER,
tdmoeMapCVLANId INTEGER,
tdmoeMapCVLANPriority INTEGER,
tdmoeMapSVLANId INTEGER,
tdmoeMapSVLANPriority INTEGER,
toeMapBP INTEGER,
toeMapBPMS INTEGER,
toeMapBPMode INTEGER,
toeMapBPSecUdpPW INTEGER,
toeMapBPPriUdpHB INTEGER,
toeMapBPSecUdpHB INTEGER,
toeMapBPSecIP IpAddress,
toeMapBPCVLANId INTEGER,
toeMapBPCVLANPriority INTEGER,
toeMapBPSVLANId INTEGER,
toeMapBPSVLANPriority INTEGER,
tdmoeMapBuType INTEGER,
tdmoeMapEcid INTEGER,
tdmoeMapDestMACAddr DisplayString
}
tdmoeMapBundleIDIndex OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { timeSlotIpInfoEntry 3 }
tdmoeMapSrcUdpPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Udp Num"
::= { timeSlotIpInfoEntry 4 }
tdmoeMapFormat OBJECT-TYPE
SYNTAX INTEGER {
aal1(1),
cesopsn(2),
satop(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Format"
::= { timeSlotIpInfoEntry 5 }
tdmoeMapCellInBundle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Cells Num"
::= { timeSlotIpInfoEntry 6 }
tdmoeMapJit-Tolerance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Jitter Delay"
::= { timeSlotIpInfoEntry 7 }
tdmoeMapJit-Buffer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Jitter Size"
::= { timeSlotIpInfoEntry 8 }
tdmoeMapDestIPAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Address"
::= { timeSlotIpInfoEntry 9 }
tdmoeMapTos OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TOS Number"
::= { timeSlotIpInfoEntry 10 }
tdmoeMapStratum OBJECT-TYPE
SYNTAX INTEGER {
stratum1(1),
stratum2(2),
stratum3(3),
stratum3e(4),
stratum4(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Stratum Setup"
::= { timeSlotIpInfoEntry 11 }
tdmoeMapVLAN OBJECT-TYPE
SYNTAX INTEGER {
off(1),
cvlan(2),
svlan(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"VLAN switch"
::= { timeSlotIpInfoEntry 12 }
tdmoeMapCVLANId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { timeSlotIpInfoEntry 13 }
tdmoeMapCVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { timeSlotIpInfoEntry 14 }
tdmoeMapSVLANId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= { timeSlotIpInfoEntry 15 }
tdmoeMapSVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { timeSlotIpInfoEntry 16 }
toeMapBP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle protection enable"
::= { timeSlotIpInfoEntry 17}
toeMapBPMS OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Master or Slave"
::= { timeSlotIpInfoEntry 18}
toeMapBPMode OBJECT-TYPE
SYNTAX INTEGER {
non-Revertible(1),
revertible(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Revertible"
::= { timeSlotIpInfoEntry 19}
toeMapBPSecUdpPW OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary PW UDP port"
::= { timeSlotIpInfoEntry 20}
toeMapBPPriUdpHB OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary HB UDP port"
::= { timeSlotIpInfoEntry 21}
toeMapBPSecUdpHB OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary HB UDP port"
::= { timeSlotIpInfoEntry 22}
toeMapBPSecIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secodary Destination IP"
::= { timeSlotIpInfoEntry 23}
toeMapBPCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN ID"
::= { timeSlotIpInfoEntry 24}
toeMapBPCVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"customer VLAN Priority"
::= { timeSlotIpInfoEntry 25}
toeMapBPSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4094)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN ID"
::= {timeSlotIpInfoEntry 26}
toeMapBPSVLANPriority OBJECT-TYPE
SYNTAX INTEGER {
p-0(1),
p-1(2),
p-2(3),
p-3(4),
p-4(5),
p-5(6),
p-6(7),
p-7(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"provider VLAN Priority"
::= { timeSlotIpInfoEntry 27}
tdmoeMapBuType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
cesoEth(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"BuType"
::= { timeSlotIpInfoEntry 28 }
tdmoeMapEcid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ECID"
::= { timeSlotIpInfoEntry 29 }
tdmoeMapDestMACAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Address"
::= { timeSlotIpInfoEntry 30 }
-- Bundle Delay/Size Info
toeBundleDelayInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF ToeBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle Delay Info."
::= { timeSlotIpMapTable 5 }
toeBundleDelayInfoEntry OBJECT-TYPE
SYNTAX ToeBundleDelayInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle Delay Info Entry"
INDEX { toeBDInfoSlot , toeBDInfoPort , toeBDInfoBundleID }
::= {toeBundleDelayInfoTable 1 }
ToeBundleDelayInfoEntry ::= SEQUENCE {
toeBDInfoSlot LargeSlotIndex,
toeBDInfoPort Tributaryport,
toeBDInfoBundleID Bundleid2,
toeBDInfoFormat INTEGER,
toeBDInfoUdpNumber INTEGER,
toeBDInfoPktPerSec INTEGER,
toeBDInfoPropDelay DisplayString,
toeBDInfoPktSize DisplayString,
toeBDInfoOverHead DisplayString
}
toeBDInfoSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot ID"
::= {toeBundleDelayInfoEntry 1 }
toeBDInfoPort OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { toeBundleDelayInfoEntry 2 }
toeBDInfoBundleID OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { toeBundleDelayInfoEntry 3 }
toeBDInfoFormat OBJECT-TYPE
SYNTAX INTEGER {
aal1(1),
cesopsn(2),
satop(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Format"
::= {toeBundleDelayInfoEntry 4 }
toeBDInfoUdpNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Udp Num"
::= { toeBundleDelayInfoEntry 5 }
toeBDInfoPktPerSec OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Map Cells Num"
::= {toeBundleDelayInfoEntry 6 }
toeBDInfoPropDelay OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Propagation Delay"
::= { toeBundleDelayInfoEntry 7}
toeBDInfoPktSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Packet Size"
::= { toeBundleDelayInfoEntry 8}
toeBDInfoOverHead OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OverHead"
::= { toeBundleDelayInfoEntry 9}
-- Bundle Protection Status
toeBundleProtectInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF ToeBundleProtectInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle Delay Info."
::= { timeSlotIpMapTable 6 }
toeBundleProtectInfoEntry OBJECT-TYPE
SYNTAX ToeBundleProtectInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle Delay Info Entry"
INDEX { toeBPInfoSlot , toeBPInfoPort , toeBPInfoBundleID }
::= {toeBundleProtectInfoTable 1 }
ToeBundleProtectInfoEntry ::= SEQUENCE {
toeBPInfoSlot LargeSlotIndex,
toeBPInfoPort Tributaryport,
toeBPInfoBundleID Bundleid2,
toeBPInfoPriHB INTEGER,
toeBPInfoPriState INTEGER,
toeBPInfoSecHB INTEGER,
toeBPInfoSecState INTEGER,
toeBPInfoBDStatus INTEGER,
toeBPInfoPriLost INTEGER,
toeBPInfoSecLost INTEGER
}
toeBPInfoSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot ID"
::= {toeBundleProtectInfoEntry 1 }
toeBPInfoPort OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { toeBundleProtectInfoEntry 2 }
toeBPInfoBundleID OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ID"
::= { toeBundleProtectInfoEntry 3 }
toeBPInfoPriHB OBJECT-TYPE
SYNTAX INTEGER {
down(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary HB status"
::= { toeBundleProtectInfoEntry 4 }
toeBPInfoPriState OBJECT-TYPE
SYNTAX INTEGER {
working(1),
standby(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary State"
::= { toeBundleProtectInfoEntry 5 }
toeBPInfoSecHB OBJECT-TYPE
SYNTAX INTEGER {
down(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary HB Status"
::= { toeBundleProtectInfoEntry 6 }
toeBPInfoSecState OBJECT-TYPE
SYNTAX INTEGER{
working(1),
standby(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary State"
::= { toeBundleProtectInfoEntry 7 }
toeBPInfoBDStatus OBJECT-TYPE
SYNTAX INTEGER{
inactive(1),
active(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Status"
::= { toeBundleProtectInfoEntry 8 }
toeBPInfoPriLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Primary HB lost Counter"
::= { toeBundleProtectInfoEntry 9 }
toeBPInfoSecLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Secondary HB lost Counter"
::= { toeBundleProtectInfoEntry 10}
--
-- Loopback table
--
tdmoeDiagTable OBJECT IDENTIFIER ::= { tdmoe-card 7}
tdmoeDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagonal Control Table"
::= { tdmoeDiagTable 1}
tdmoeDiagControlEntry OBJECT-TYPE
SYNTAX TdmoeDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagonal Control entry"
INDEX { tdmoeDiagSlotIndex , tdmoeDiagPort }
::= { tdmoeDiagControlTable 1 }
TdmoeDiagControlEntry ::= SEQUENCE {
tdmoeDiagSlotIndex LargeSlotIndex,
tdmoeDiagPort Tributaryport,
tdmoeLoopBack INTEGER
}
tdmoeDiagSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeDiagControlEntry 1 }
tdmoeDiagPort OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"trib port1~4 "
::= { tdmoeDiagControlEntry 2 }
tdmoeLoopBack OBJECT-TYPE
SYNTAX INTEGER {
off(1),
llb(4),
local(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"loopback type-plb:payload loopback; llb:line loopback"
::= { tdmoeDiagControlEntry 3}
tdmoeDiagMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeDiagMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagonal Map Table"
::= { tdmoeDiagTable 2}
tdmoeDiagMapEntry OBJECT-TYPE
SYNTAX TdmoeDiagMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Diagonal Control entry"
INDEX { tdmoeDiagMapSlotIndex , tdmoeDiagPortIndex , tdmoeDiagMapIndex }
::= { tdmoeDiagMapTable 1 }
TdmoeDiagMapEntry ::= SEQUENCE {
tdmoeDiagMapSlotIndex LargeSlotIndex,
tdmoeDiagPortIndex Tributaryport,
tdmoeDiagMapIndex INTEGER,
tdmoeDiagStatus INTEGER
}
tdmoeDiagMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeDiagMapEntry 1 }
tdmoeDiagPortIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"trib port1~4 "
::= { tdmoeDiagMapEntry 2 }
tdmoeDiagMapIndex OBJECT-TYPE
SYNTAX INTEGER (0..31)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"map channel 1~32 "
::= { tdmoeDiagMapEntry 3}
tdmoeDiagStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
used(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"map channel status "
::= { tdmoeDiagMapEntry 4}
--
-- Transmission delay measurement table
--
tdmoeDiagRoundTripDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeDiagRoundTripDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Round Trip Delay"
::= { tdmoeDiagTable 3 }
tdmoeDiagRoundTripDelayEntry OBJECT-TYPE
SYNTAX TdmoeDiagRoundTripDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle Delay Info Entry"
INDEX { tdmoeDiagRoundTripSlotIndex , tdmoeDiagRoundTripPortIndex ,
tdmoeDiagRoundTripBundleID }
::= {tdmoeDiagRoundTripDelayTable 1 }
TdmoeDiagRoundTripDelayEntry ::= SEQUENCE {
tdmoeDiagRoundTripSlotIndex LargeSlotIndex,
tdmoeDiagRoundTripPortIndex Tributaryport,
tdmoeDiagRoundTripBundleID Bundleid2,
tdmoeDiagRoundTripPeriod INTEGER,
tdmoeDiagRoundTripEnable INTEGER
}
tdmoeDiagRoundTripSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeDiagRoundTripDelayEntry 1 }
tdmoeDiagRoundTripPortIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"trib port 1~4 "
::= { tdmoeDiagRoundTripDelayEntry 2 }
tdmoeDiagRoundTripBundleID OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle ID "
::= { tdmoeDiagRoundTripDelayEntry 3}
tdmoeDiagRoundTripPeriod OBJECT-TYPE
-- SYNTAX INTEGER (1..600)
SYNTAX INTEGER (0..600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Period time for transmission delay measurement (second) "
::= { tdmoeDiagRoundTripDelayEntry 4 }
tdmoeDiagRoundTripEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet transmission time delay measurement control "
::= { tdmoeDiagRoundTripDelayEntry 5 }
--
-- bundle arp status table
--
tdmoeBundleArpStatusTable OBJECT IDENTIFIER ::= { tdmoeDiagTable 4}
tdmoeArpPrimaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeArpPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle arp status table"
::= {tdmoeBundleArpStatusTable 1}
tdmoeArpPrimaryStatusEntry OBJECT-TYPE
SYNTAX TdmoeArpPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle arp status table."
INDEX { arpSlotPrimaryIndex , arpPrimaryNumIndex }
::= { tdmoeArpPrimaryStatusTable 1 }
TdmoeArpPrimaryStatusEntry ::= SEQUENCE {
arpSlotPrimaryIndex LargeSlotIndex,
arpPrimaryNumIndex INTEGER (1..64),
arpPrimarySrcIpAddress IpAddress,
arpPrimaryMacAddress DisplayString,
arpPrimarySVLANId INTEGER,
arpPrimaryCVLANId INTEGER,
arpPrimaryRxRequest Counter,
arpPrimaryTxReply Counter,
arpPrimaryTxRequest Counter,
arpPrimaryRxReply Counter,
isPrimaryBundleIp INTEGER
}
arpSlotPrimaryIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeArpPrimaryStatusEntry 1 }
arpPrimaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~64) "
::= { tdmoeArpPrimaryStatusEntry 2 }
arpPrimarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { tdmoeArpPrimaryStatusEntry 3 }
arpPrimaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoeArpPrimaryStatusEntry 4 }
arpPrimarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoeArpPrimaryStatusEntry 5 }
arpPrimaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoeArpPrimaryStatusEntry 6 }
arpPrimaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { tdmoeArpPrimaryStatusEntry 7 }
arpPrimaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Reply counter"
::= { tdmoeArpPrimaryStatusEntry 8 }
arpPrimaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Request counter"
::= { tdmoeArpPrimaryStatusEntry 9 }
arpPrimaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { tdmoeArpPrimaryStatusEntry 10 }
isPrimaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { tdmoeArpPrimaryStatusEntry 11 }
tdmoeArpSecondaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeArpSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth phy electric Config Table."
::= { tdmoeBundleArpStatusTable 2 }
tdmoeArpSecondaryStatusEntry OBJECT-TYPE
SYNTAX TdmoeArpSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { arpSlotSecondaryIndex , arpSecondaryNumIndex }
::= { tdmoeArpSecondaryStatusTable 1 }
TdmoeArpSecondaryStatusEntry ::= SEQUENCE {
arpSlotSecondaryIndex LargeSlotIndex,
arpSecondaryNumIndex INTEGER (1..64),
arpSecondarySrcIpAddress IpAddress,
arpSecondaryMacAddress DisplayString,
arpSecondarySVLANId INTEGER,
arpSecondaryCVLANId INTEGER,
arpSecondaryRxRequest Counter,
arpSecondaryTxReply Counter,
arpSecondaryTxRequest Counter,
arpSecondaryRxReply Counter,
isSecondaryBundleIp INTEGER
}
arpSlotSecondaryIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeArpSecondaryStatusEntry 1 }
arpSecondaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~64) "
::= { tdmoeArpSecondaryStatusEntry 2 }
arpSecondarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { tdmoeArpSecondaryStatusEntry 3 }
arpSecondaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoeArpSecondaryStatusEntry 4 }
arpSecondarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoeArpSecondaryStatusEntry 5 }
arpSecondaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoeArpSecondaryStatusEntry 6 }
arpSecondaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { tdmoeArpSecondaryStatusEntry 7 }
arpSecondaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Reply counter"
::= { tdmoeArpSecondaryStatusEntry 8 }
arpSecondaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Tx Request counter"
::= { tdmoeArpSecondaryStatusEntry 9 }
arpSecondaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { tdmoeArpSecondaryStatusEntry 10 }
isSecondaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { tdmoeArpSecondaryStatusEntry 11 }
tdmoeArpOtherStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeArpOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth phy electric Config Table."
::= { tdmoeBundleArpStatusTable 3 }
tdmoeArpOtherStatusEntry OBJECT-TYPE
SYNTAX TdmoeArpOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { arpSlotOtherIndex , arpOtherNumIndex }
::= { tdmoeArpOtherStatusTable 1 }
TdmoeArpOtherStatusEntry ::= SEQUENCE {
arpSlotOtherIndex LargeSlotIndex,
arpOtherNumIndex INTEGER (1..8),
arpOtherSrcIpAddress IpAddress,
arpOtherMacAddress DisplayString,
arpOtherSVLANId INTEGER,
arpOtherCVLANId INTEGER,
arpOtherRxRequest Counter,
arpOtherRxReply Counter
}
arpSlotOtherIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeArpOtherStatusEntry 1 }
arpOtherNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle arp number Index(1~8) "
::= { tdmoeArpOtherStatusEntry 2 }
arpOtherSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source IP."
::= { tdmoeArpOtherStatusEntry 3 }
arpOtherMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle arp Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoeArpOtherStatusEntry 4 }
arpOtherSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoeArpOtherStatusEntry 5 }
arpOtherCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoeArpOtherStatusEntry 6 }
arpOtherRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Request counter"
::= { tdmoeArpOtherStatusEntry 7 }
arpOtherRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Arp Rx Reply counter"
::= { tdmoeArpOtherStatusEntry 8 }
--
-- bundle ping status table
--
tdmoeBundlePingStatusTable OBJECT IDENTIFIER ::= { tdmoeDiagTable 5}
tdmoePingPrimaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoePingPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {tdmoeBundlePingStatusTable 1}
tdmoePingPrimaryStatusEntry OBJECT-TYPE
SYNTAX TdmoePingPrimaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pingSlotPrimaryIndex , pingPrimaryNumIndex }
::= { tdmoePingPrimaryStatusTable 1 }
TdmoePingPrimaryStatusEntry ::= SEQUENCE {
pingSlotPrimaryIndex LargeSlotIndex,
pingPrimaryNumIndex INTEGER (1..64),
pingPrimarySrcIpAddress IpAddress,
pingPrimaryMacAddress DisplayString,
pingPrimarySVLANId INTEGER,
pingPrimaryCVLANId INTEGER,
pingPrimaryRxRequest Counter,
pingPrimaryTxReply Counter,
pingPrimaryTxRequest Counter,
pingPrimaryRxReply Counter,
isPPrimaryBundleIp INTEGER
}
pingSlotPrimaryIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoePingPrimaryStatusEntry 1 }
pingPrimaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~64) "
::= { tdmoePingPrimaryStatusEntry 2 }
pingPrimarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { tdmoePingPrimaryStatusEntry 3 }
pingPrimaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoePingPrimaryStatusEntry 4 }
pingPrimarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoePingPrimaryStatusEntry 5 }
pingPrimaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoePingPrimaryStatusEntry 6 }
pingPrimaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { tdmoePingPrimaryStatusEntry 7 }
pingPrimaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Reply counter"
::= { tdmoePingPrimaryStatusEntry 8 }
pingPrimaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Request counter"
::= { tdmoePingPrimaryStatusEntry 9 }
pingPrimaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { tdmoePingPrimaryStatusEntry 10 }
isPPrimaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { tdmoePingPrimaryStatusEntry 11 }
-- ping Secordary
tdmoePingSecondaryStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoePingSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {tdmoeBundlePingStatusTable 2}
tdmoePingSecondaryStatusEntry OBJECT-TYPE
SYNTAX TdmoePingSecondaryStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pingSlotSecondaryIndex , pingSecondaryNumIndex }
::= { tdmoePingSecondaryStatusTable 1 }
TdmoePingSecondaryStatusEntry ::= SEQUENCE {
pingSlotSecondaryIndex LargeSlotIndex,
pingSecondaryNumIndex INTEGER (1..64),
pingSecondarySrcIpAddress IpAddress,
pingSecondaryMacAddress DisplayString,
pingSecondarySVLANId INTEGER,
pingSecondaryCVLANId INTEGER,
pingSecondaryRxRequest Counter,
pingSecondaryTxReply Counter,
pingSecondaryTxRequest Counter,
pingSecondaryRxReply Counter,
isPSecondaryBundleIp INTEGER
}
pingSlotSecondaryIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoePingSecondaryStatusEntry 1 }
pingSecondaryNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~64) "
::= { tdmoePingSecondaryStatusEntry 2 }
pingSecondarySrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { tdmoePingSecondaryStatusEntry 3 }
pingSecondaryMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoePingSecondaryStatusEntry 4 }
pingSecondarySVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoePingSecondaryStatusEntry 5 }
pingSecondaryCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoePingSecondaryStatusEntry 6 }
pingSecondaryRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { tdmoePingSecondaryStatusEntry 7 }
pingSecondaryTxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Reply counter"
::= { tdmoePingSecondaryStatusEntry 8 }
pingSecondaryTxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Tx Request counter"
::= { tdmoePingSecondaryStatusEntry 9 }
pingSecondaryRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { tdmoePingSecondaryStatusEntry 10 }
isPSecondaryBundleIp OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Is bundle ip Set"
::= { tdmoePingSecondaryStatusEntry 11 }
-- other
tdmoePingOtherStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoePingOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle ping status table"
::= {tdmoeBundlePingStatusTable 3}
tdmoePingOtherStatusEntry OBJECT-TYPE
SYNTAX TdmoePingOtherStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle ping status table."
INDEX { pingSlotOtherIndex , pingOtherNumIndex }
::= { tdmoePingOtherStatusTable 1 }
TdmoePingOtherStatusEntry ::= SEQUENCE {
pingSlotOtherIndex LargeSlotIndex,
pingOtherNumIndex INTEGER (1..8),
pingOtherSrcIpAddress IpAddress,
pingOtherMacAddress DisplayString,
pingOtherSVLANId INTEGER,
pingOtherCVLANId INTEGER,
pingOtherRxRequest Counter,
pingOtherRxReply Counter
}
pingSlotOtherIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoePingOtherStatusEntry 1 }
pingOtherNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle ping number Index(1~8) "
::= { tdmoePingOtherStatusEntry 2 }
pingOtherSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source IP."
::= { tdmoePingOtherStatusEntry 3 }
pingOtherMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle ping Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoePingOtherStatusEntry 4 }
pingOtherSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoePingOtherStatusEntry 5 }
pingOtherCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoePingOtherStatusEntry 6 }
pingOtherRxRequest OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Request counter"
::= { tdmoePingOtherStatusEntry 7 }
pingOtherRxReply OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ping Rx Reply counter"
::= { tdmoePingOtherStatusEntry 8 }
--
-- IP Conflict
--
tdmoeIpConflictTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeIpConflictEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bundle IP Conflict status table."
::= {tdmoeDiagTable 6}
tdmoeIpConflictEntry OBJECT-TYPE
SYNTAX TdmoeIpConflictEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Bundle IP Conflict status table."
INDEX { ipConflictSlotIndex , ipConflictNumIndex }
::= { tdmoeIpConflictTable 1 }
TdmoeIpConflictEntry ::= SEQUENCE {
ipConflictSlotIndex LargeSlotIndex,
ipConflictNumIndex INTEGER (1..16),
ipConflictSrcIpAddress IpAddress,
ipConflictMacAddress DisplayString,
ipConflictSVLANId INTEGER,
ipConflictCVLANId INTEGER
}
ipConflictSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeIpConflictEntry 1 }
ipConflictNumIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle IP Conflict Number Index(1~64) "
::= { tdmoeIpConflictEntry 2 }
ipConflictSrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle IP Conflict Source IP."
::= { tdmoeIpConflictEntry 3 }
ipConflictMacAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bundle IP Conflict Source Mac (xx:xx:xx:xx:xx:xx)"
::= { tdmoeIpConflictEntry 4 }
ipConflictSVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SVlan Index"
::= { tdmoeIpConflictEntry 5 }
ipConflictCVLANId OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CVlan Index"
::= { tdmoeIpConflictEntry 6 }
--
-- Bundle Statistics Table
--
tdmoeStatusAndStatisticsTable OBJECT IDENTIFIER ::= { tdmoe-card 8}
tdmoeBundleStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeBundleStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"bundle statistics table"
::= {tdmoeStatusAndStatisticsTable 1}
tdmoebundleStatisticsEntry OBJECT-TYPE
SYNTAX TdmoeBundleStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in bundle statistics table."
INDEX { bundleSlotIndex , bundleTribIndex ,
bundleBundleIDIndex }
::= { tdmoeBundleStatisticsTable 1 }
TdmoeBundleStatisticsEntry ::= SEQUENCE {
bundleSlotIndex LargeSlotIndex,
bundleTribIndex Tributaryport,
bundleBundleIDIndex Bundleid2,
bundleJit-Buf-Underrun Counter,
bundleJit-Buf-Overrun Counter,
bundleMinJitBuffer Gauge,
bundleMaxJitBuffer Gauge,
bundleRx-Lost Counter,
bundleRx-Good Counter,
bundleTx-Good Counter,
bundleJumped Counter,
bundleRe-order Counter,
toeBundleClear INTEGER
}
bundleSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoebundleStatisticsEntry 1 }
bundleTribIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE alarm portIndex"
::= { tdmoebundleStatisticsEntry 2 }
bundleBundleIDIndex OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TDMoE bundle 1-32"
::= { tdmoebundleStatisticsEntry 3 }
bundleJit-Buf-Underrun OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TXC Byte Received"
::= { tdmoebundleStatisticsEntry 4 }
bundleJit-Buf-Overrun OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TXC Byte Transmitted"
::= { tdmoebundleStatisticsEntry 5 }
bundleMinJitBuffer OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TXC Classified Packets Received"
::= { tdmoebundleStatisticsEntry 6 }
bundleMaxJitBuffer OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Byte Received"
::= { tdmoebundleStatisticsEntry 7 }
bundleRx-Lost OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Byte Transmitted"
::= { tdmoebundleStatisticsEntry 8 }
bundleRx-Good OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Packets Received"
::= { tdmoebundleStatisticsEntry 9 }
bundleTx-Good OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wan Packets Tranmitted"
::= { tdmoebundleStatisticsEntry 10 }
bundleJumped OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Jumped packets"
::= { tdmoebundleStatisticsEntry 11 }
bundleRe-order OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"re-order packets"
::= { tdmoebundleStatisticsEntry 12 }
toeBundleClear OBJECT-TYPE
SYNTAX INTEGER {
no(1),
clear(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear Bundle Count"
::= { tdmoebundleStatisticsEntry 13 }
--
-- Traffic Statistics Table
--
tdmoeEthPortStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeEthPortStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"bundle statistics table"
::= {tdmoeStatusAndStatisticsTable 2}
tdmoeEthPortStatisticsEntry OBJECT-TYPE
SYNTAX TdmoeEthPortStatisticsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in bundle statistics table."
INDEX { trafficSlotIndex , trafficPortIndex }
::= { tdmoeEthPortStatisticsTable 1 }
TdmoeEthPortStatisticsEntry ::= SEQUENCE {
trafficSlotIndex LargeSlotIndex,
trafficPortIndex EthportIndex,
trafficTx-Packets Counter,
trafficTx-Bytes Counter,
trafficTx-UnicastPackets Counter,
trafficTx-MulticastPackets Counter,
trafficTx-BroadcastPackets Counter,
trafficTx-PausePackets Counter,
trafficRx-Packets Counter,
trafficRx-Bytes Counter,
trafficRx-UnicastPackets Counter,
trafficRx-MulticastPackets Counter,
trafficRx-BroadcastPackets Counter,
trafficRx-PausePackets Counter,
trafficRx-BulkyPackets Counter,
trafficRx-ShortyPackets Counter,
trafficRx-FragmentPackets Counter,
trafficCRCError Counter
}
trafficSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeEthPortStatisticsEntry 1 }
trafficPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Index"
::= { tdmoeEthPortStatisticsEntry 2 }
trafficTx-Packets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good transmitted frames "
::= { tdmoeEthPortStatisticsEntry 3 }
trafficTx-Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good transmitted bytes "
::= { tdmoeEthPortStatisticsEntry 4 }
trafficTx-UnicastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent that have a unicast destination MAC address."
::= { tdmoeEthPortStatisticsEntry 5}
trafficTx-MulticastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent that have a multicast destination MAC address."
::= { tdmoeEthPortStatisticsEntry 6}
trafficTx-BroadcastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent that have a broadcast destination MAC address."
::= { tdmoeEthPortStatisticsEntry 7}
trafficTx-PausePackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted pause packets."
::= { tdmoeEthPortStatisticsEntry 8}
trafficRx-Packets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good received packets "
::= { tdmoeEthPortStatisticsEntry 9}
trafficRx-Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good received bytes "
::= { tdmoeEthPortStatisticsEntry 10 }
trafficRx-UnicastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { tdmoeEthPortStatisticsEntry 11}
trafficRx-MulticastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent that have a multicast destination MAC address."
::= { tdmoeEthPortStatisticsEntry 12}
trafficRx-BroadcastPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent that have a multicast destination MAC address."
::= { tdmoeEthPortStatisticsEntry 13}
trafficRx-PausePackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"transmitted pause packets."
::= { tdmoeEthPortStatisticsEntry 14}
trafficRx-BulkyPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total frames received with a length of more than MaxSize octets(ethernet packet length 1514) but with a valid FCS."
::= { tdmoeEthPortStatisticsEntry 15 }
trafficRx-ShortyPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total frames received with a length of less than 64 octets but with a valid FCS."
::= { tdmoeEthPortStatisticsEntry 16}
trafficRx-FragmentPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { tdmoeEthPortStatisticsEntry 17}
trafficCRCError OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total frames received with a CRC error"
::= { tdmoeEthPortStatisticsEntry 18}
tdmoeBundleStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeBundleStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"bundle statistics table"
::= {tdmoeStatusAndStatisticsTable 3}
tdmoeBundleStatusEntry OBJECT-TYPE
SYNTAX TdmoeBundleStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in bundle statistics table."
INDEX { bundleSlotIndex , bundleTribIndex ,
bundleBundleIDIndex }
::= { tdmoeBundleStatusTable 1 }
TdmoeBundleStatusEntry ::= SEQUENCE {
bundleStatus INTEGER
}
bundleStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive (1),
active (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bundle Status"
::= { tdmoeBundleStatusEntry 4 }
tdmoeEthPortStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeEthPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth port Status Table."
::= { tdmoeStatusAndStatisticsTable 4 }
tdmoeEthPortStatusEntry OBJECT-TYPE
SYNTAX TdmoeEthPortStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Eth Phy Config Entry."
INDEX { enetSlotIndex , enetPortIndex }
::= { tdmoeEthPortStatusTable 1 }
TdmoeEthPortStatusEntry ::= SEQUENCE {
enetSlotIndex LargeSlotIndex,
enetPortIndex EthportIndex,
enetState INTEGER,
enetAutoNegotiation INTEGER,
enetSpeed INTEGER,
enetDuplex INTEGER,
enetAutolaserShutdown INTEGER,
link INTEGER,
enetPulseRepetitionTime INTEGER
}
enetSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeEthPortStatusEntry 1 }
enetPortIndex OBJECT-TYPE
SYNTAX EthportIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"eth port 1-4"
::= { tdmoeEthPortStatusEntry 2 }
enetState OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port State"
::= { tdmoeEthPortStatusEntry 3 }
enetAutoNegotiation OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"auto negotiation state"
::= {tdmoeEthPortStatusEntry 4 }
enetSpeed OBJECT-TYPE
SYNTAX INTEGER {
mbps-10 (1),
mbps-100 (2),
mbps-1000 (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port speed 10/100/1000 mbps"
::= {tdmoeEthPortStatusEntry 5 }
enetDuplex OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port duplex mode(half/full)"
::= {tdmoeEthPortStatusEntry 6 }
enetAutolaserShutdown OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"autolasershutdown state"
::= {tdmoeEthPortStatusEntry 7}
link OBJECT-TYPE
SYNTAX INTEGER {
down (1),
up (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"autolasershutdown state"
::= {tdmoeEthPortStatusEntry 8}
enetPulseRepetitionTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ALS/APSD pulse repetition time for automatic restart(sec)"
::= { tdmoeEthPortStatusEntry 9 }
-- Optical Information Table
--
tdmoeOpticalInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF OpticalInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"optical information table"
::= {tdmoeStatusAndStatisticsTable 5}
opticalInfoEntry OBJECT-TYPE
SYNTAX OpticalInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in optical information table."
INDEX { opticalSlotIndex , opticalPortIndex }
::= { tdmoeOpticalInformationTable 1 }
OpticalInfoEntry ::= SEQUENCE {
opticalSlotIndex LargeSlotIndex,
opticalPortIndex INTEGER,
opticalConnector INTEGER,
opticalTransceiver DisplayString,
opticalLinkLength DisplayString,
opticalTechnology DisplayString,
opticalEncoding DisplayString,
opticalLength-9-125-mm DisplayString,
opticalLength-50-125-mm DisplayString,
opticalLength-62p5-125-mm DisplayString,
opticalTemperature DisplayString,
opticalVcc DisplayString,
opticalTxBias DisplayString,
opticalTxPower DisplayString,
opticalRxPower DisplayString,
opticalDate DisplayString,
opticalVendorName DisplayString,
opticalOUI DisplayString,
opticalPN DisplayString,
opticalRev DisplayString,
opticalWavelength DisplayString
}
opticalSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { opticalInfoEntry 1 }
opticalPortIndex OBJECT-TYPE
SYNTAX INTEGER {
eth-1 (1),
eth-2 (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"optical port"
::= { opticalInfoEntry 2 }
opticalConnector OBJECT-TYPE
SYNTAX INTEGER {
not-available(1),
sc(2),
fiber-channel-style-1-copper(3),
fiber-channel-style-2-copper(4),
bnc-tnc(5),
fibre-channel-coaxial-header(6),
fiberJack(7),
lc(8),
mt-rj(9),
mu(10),
sg(11),
optcal-pigtail(12),
hssdc-ii(13),
copper-pigtail(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP connector"
::= { opticalInfoEntry 3 }
opticalTransceiver OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP transceiver"
::= { opticalInfoEntry 4 }
opticalLinkLength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP link length"
::= { opticalInfoEntry 5 }
opticalTechnology OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP technology"
::= { opticalInfoEntry 6 }
opticalEncoding OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP encoding"
::= { opticalInfoEntry 7 }
opticalLength-9-125-mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 9/125 mm fiber"
::= { opticalInfoEntry 8 }
opticalLength-50-125-mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 50/125 mm fiber"
::= { opticalInfoEntry 9 }
opticalLength-62p5-125-mm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP length for 62.5/125 mm fiber"
::= { opticalInfoEntry 10 }
opticalTemperature OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Temperature"
::= { opticalInfoEntry 11 }
opticalVcc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Vcc"
::= { opticalInfoEntry 12 }
opticalTxBias OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Tx Bias current"
::= { opticalInfoEntry 13 }
opticalTxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Tx power"
::= { opticalInfoEntry 14 }
opticalRxPower OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 15 }
opticalDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 16 }
opticalVendorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 17 }
opticalOUI OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 18 }
opticalPN OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 19 }
opticalRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 20 }
opticalWavelength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SFP Rx power"
::= { opticalInfoEntry 21 }
--
-- Transmission delay measurement map table
--
tdmoeDiagRoundTripMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeDiagRoundTripMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Transmission delay measurement map table"
::= {tdmoeStatusAndStatisticsTable 6}
tdmoeDiagRoundTripMapEntry OBJECT-TYPE
SYNTAX TdmoeDiagRoundTripMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in transmission delay measurement map table."
INDEX { diagRoundTripMapSlotIndex , diagRoundTripMapPortIndex }
::= { tdmoeDiagRoundTripMapTable 1 }
TdmoeDiagRoundTripMapEntry ::= SEQUENCE {
diagRoundTripMapSlotIndex LargeSlotIndex,
diagRoundTripMapPortIndex Tributaryport,
diagRoundTripMapBundleID Bundleid2,
diagRoundTripMapPeriod INTEGER,
diagRoundTripMapEnable INTEGER,
diagRoundTripMapErrorCode INTEGER,
diagRoundTripMapElapseTime INTEGER,
diagRoundTripMapMax DisplayString,
diagRoundTripMapMin DisplayString,
diagRoundTripMapAvg DisplayString,
diagRoundTripMapPacketLoss Counter
}
diagRoundTripMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { tdmoeDiagRoundTripMapEntry 1 }
diagRoundTripMapPortIndex OBJECT-TYPE
SYNTAX Tributaryport
ACCESS read-only
STATUS mandatory
DESCRIPTION
"trib port 1~4 "
::= { tdmoeDiagRoundTripMapEntry 2 }
diagRoundTripMapBundleID OBJECT-TYPE
SYNTAX Bundleid2
ACCESS read-only
STATUS mandatory
DESCRIPTION
"bundle ID "
::= { tdmoeDiagRoundTripMapEntry 3}
diagRoundTripMapPeriod OBJECT-TYPE
SYNTAX INTEGER (0..600) --//RIKER2021 SilverCreek
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Period time for transmission delay measurement (second) "
::= { tdmoeDiagRoundTripMapEntry 4 }
diagRoundTripMapEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ethernet transmission time delay measurement control "
::= { tdmoeDiagRoundTripMapEntry 5 }
diagRoundTripMapErrorCode OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
inactive-delay-measurement(2),
no-measurement-available(3),
not-receive-any-return-packet(5),
packet-loss-too-much(9),
na(254),
unknown-problem(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Test measurement result: 2, 3, 4, etc..
Result 2 means 'test ok.'.
Result 3 means 'Bundle inactive delay measurement not available.'.
Result 4 means 'Did not receive any return packet, no measurement available, please retest.'."
::= { tdmoeDiagRoundTripMapEntry 6 }
diagRoundTripMapElapseTime OBJECT-TYPE
SYNTAX INTEGER (0..600)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapsed time (second) "
::= { tdmoeDiagRoundTripMapEntry 7 }
diagRoundTripMapMax OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum transmission delay time (millisecond) "
::= { tdmoeDiagRoundTripMapEntry 8 }
diagRoundTripMapMin OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum transmission delay time (millisecond) "
::= { tdmoeDiagRoundTripMapEntry 9 }
diagRoundTripMapAvg OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average transmission delay time (millisecond) "
::= { tdmoeDiagRoundTripMapEntry 10 }
diagRoundTripMapPacketLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Round trip test packet loss "
::= { tdmoeDiagRoundTripMapEntry 11 }
--
-- SYSTEM Information Table
--
tdmoeSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { tdmoe-card 9}
systemInformationEntry OBJECT-TYPE
SYNTAX SystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { tdmoeSlotIndex }
::= { tdmoeSystemInformationTable 1 }
SystemInformationEntry ::= SEQUENCE {
tdmoePROMVersion DisplayString,
tdmoeHardwareVersion DisplayString,
tdmoeFpgaVersion DisplayString,
tdmoeOscType DisplayString,
tdmoeBank1Version DisplayString,
tdmoeBank2Version DisplayString,
tdmoeActiveBank INTEGER,
tdmoeNextBank INTEGER
}
tdmoePROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" tdmoe PROM Version"
::= { systemInformationEntry 2 }
tdmoeHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" tdmoe Hardware Version"
::= { systemInformationEntry 3 }
tdmoeFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { systemInformationEntry 4 }
tdmoeOscType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"osc version"
::= { systemInformationEntry 5 }
tdmoeBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { systemInformationEntry 6 }
tdmoeBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { systemInformationEntry 7}
tdmoeActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { systemInformationEntry 8 }
tdmoeNextBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Next Bank 1/2"
::= { systemInformationEntry 9 }
--
-- Command Control Table
--
tdmoeCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TdmoeCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { tdmoe-card 10}
tdmoeCommandControlEntry OBJECT-TYPE
SYNTAX TdmoeCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { tdmoeSlotIndex }
::= { tdmoeCommandControlTable 1 }
TdmoeCommandControlEntry ::= SEQUENCE {
tdmoePerfReset INTEGER,
tdmoeAlarmHistoryReset INTEGER,
tdmoeCardReset INTEGER,
tdmoeLoadDefault INTEGER
}
tdmoePerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { tdmoeCommandControlEntry 2 }
tdmoeAlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { tdmoeCommandControlEntry 3 }
tdmoeCardReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset "
::= { tdmoeCommandControlEntry 4 }
tdmoeLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default"
::= { tdmoeCommandControlEntry 5}
--
-- Vlan VID setup table
--
toeVlanSetupVidTable OBJECT-TYPE
SYNTAX SEQUENCE OF ToeVlanSetupVidEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMOE Vlan VID setup table"
::= { tdmoe-card 11 }
toeVlanSetupVidEntry OBJECT-TYPE
SYNTAX ToeVlanSetupVidEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in TDMOE Vlan VID setup table"
INDEX { tvSetupVidSlot }
::= { toeVlanSetupVidTable 1 }
ToeVlanSetupVidEntry ::= SEQUENCE {
tvSetupVidSlot LargeSlotIndex,
tvVLAN802-1Q INTEGER,
tvTdmPvid INTEGER,
tvEth1Pvid INTEGER,
tvEth2Pvid INTEGER,
tvEth3Pvid INTEGER,
tvEth4Pvid INTEGER
}
tvSetupVidSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { toeVlanSetupVidEntry 1 }
tvVLAN802-1Q OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"802.1Q VLAN"
::= { toeVlanSetupVidEntry 2 }
tvTdmPvid OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VID for TDM"
::= { toeVlanSetupVidEntry 3 }
tvEth1Pvid OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VID for ethernet port 1"
::= { toeVlanSetupVidEntry 4 }
tvEth2Pvid OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VID for ethernet port 2"
::= { toeVlanSetupVidEntry 5 }
tvEth3Pvid OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VID for ethernet port 3"
::= { toeVlanSetupVidEntry 6 }
tvEth4Pvid OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"VID for ethernet port 4"
::= { toeVlanSetupVidEntry 7 }
--
-- Vlan Group Setup Table
--
-- Hao 3/27 2013
toeVlanSetupGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF ToeVlanSetupGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Vlan Group Setup Table"
::= { tdmoe-card 12 }
toeVlanSetupGroupEntry OBJECT-TYPE
SYNTAX ToeVlanSetupGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in Vlan Group Setup Table"
INDEX { tvSetupGroupSlot , tvGroupIndex }
::= { toeVlanSetupGroupTable 1 }
ToeVlanSetupGroupEntry ::= SEQUENCE {
tvSetupGroupSlot LargeSlotIndex,
tvGroupIndex INTEGER,
tvTdmTag INTEGER,
tvEth1Tag INTEGER,
tvEth2Tag INTEGER,
tvEth3Tag INTEGER,
tvEth4Tag INTEGER,
tvVlanID INTEGER,
tvEnable INTEGER
}
tvSetupGroupSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { toeVlanSetupGroupEntry 1 }
tvGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"group index"
::= { toeVlanSetupGroupEntry 2 }
tvTdmTag OBJECT-TYPE
SYNTAX INTEGER {
no(1),
tag(2),
untag(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan tdm tag/uptag"
::= { toeVlanSetupGroupEntry 3 }
tvEth1Tag OBJECT-TYPE
SYNTAX INTEGER {
no(1),
tag(2),
untag(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan ethernet port 1 tag/uptag"
::= { toeVlanSetupGroupEntry 4 }
tvEth2Tag OBJECT-TYPE
SYNTAX INTEGER {
no(1),
tag(2),
untag(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan ethernet port 2 tag/uptag"
::= { toeVlanSetupGroupEntry 5 }
tvEth3Tag OBJECT-TYPE
SYNTAX INTEGER {
no(1),
tag(2),
untag(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan ethernet port 3 tag/uptag"
::= { toeVlanSetupGroupEntry 6 }
tvEth4Tag OBJECT-TYPE
SYNTAX INTEGER {
no(1),
tag(2),
untag(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan ethernet port 4 tag/uptag"
::= { toeVlanSetupGroupEntry 7 }
tvVlanID OBJECT-TYPE
SYNTAX INTEGER (1..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"vlan vid"
::= { toeVlanSetupGroupEntry 8 }
--Hao 3/27 2013
tvEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"group enable"
::= { toeVlanSetupGroupEntry 9 }
--
-- tdmoeClockSourceConfigTable
--
tdmoeClockSourceConfigTable OBJECT IDENTIFIER ::= { tdmoe-card 13 }
portModeConfig OBJECT-TYPE
SYNTAX SEQUENCE OF PortModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port Clock Source Mode Config Table."
::= { tdmoeClockSourceConfigTable 1 }
portModeConfigEntry OBJECT-TYPE
SYNTAX PortModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port Clock Source Mode Config Entry"
INDEX { tdmoeClockSourceSlotIndex }
::= { portModeConfig 1 }
PortModeConfigEntry ::= SEQUENCE {
tdmoeClockSourceSlotIndex LargeSlotIndex,
tdmoeClockSourcePort1 INTEGER,
tdmoeClockSourcePort2 INTEGER,
tdmoeClockSourcePort3 INTEGER,
tdmoeClockSourcePort4 INTEGER
}
tdmoeClockSourceSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { portModeConfigEntry 1 }
tdmoeClockSourcePort1 OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4),
eth1SyncE(5),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portModeConfigEntry 2 }
tdmoeClockSourcePort2 OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4),
eth2SyncE(5),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portModeConfigEntry 3 }
tdmoeClockSourcePort3 OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4),
eth3SyncE(5),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portModeConfigEntry 4 }
tdmoeClockSourcePort4 OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4),
eth4SyncE(5),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portModeConfigEntry 5 }
portACRConfig OBJECT-TYPE
SYNTAX SEQUENCE OF PortACRConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port ACR Config Table."
::= { tdmoeClockSourceConfigTable 2 }
portACRConfigEntry OBJECT-TYPE
SYNTAX PortACRConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port ACR Config Entry"
INDEX { tdmoeACRSlotIndex , tdmoeACRIndex }
::= { portACRConfig 1 }
PortACRConfigEntry ::= SEQUENCE {
tdmoeACRSlotIndex LargeSlotIndex,
tdmoeACRIndex INTEGER,
tdmoeACRTribID INTEGER,
tdmoeACRBundleID Integer32,
tdmoeACREnable INTEGER,
tdmoeACRStatus INTEGER
}
tdmoeACRSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { portACRConfigEntry 1 }
tdmoeACRIndex OBJECT-TYPE
SYNTAX INTEGER {
acr1(1),
acr2(2),
acr3(3),
acr4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portACRConfigEntry 2 }
tdmoeACRTribID OBJECT-TYPE
SYNTAX INTEGER {
trib1(1),
trib2(2),
trib3(3),
trib4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portACRConfigEntry 3 }
tdmoeACRBundleID OBJECT-TYPE
SYNTAX Integer32 (0..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portACRConfigEntry 4 }
tdmoeACREnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portACRConfigEntry 5 }
tdmoeACRStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
acquisition(2),
tracking1(3),
tracking2(4),
tracking3(5),
tracking4(6),
tracking5(7),
none(99)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Clock Source Port Mode."
::= { portACRConfigEntry 6 }
timeStampUploadConfig OBJECT-TYPE
SYNTAX SEQUENCE OF TimeStampUploadConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port ACR Config Table."
::= { tdmoeClockSourceConfigTable 3 }
timeStampUploadConfigEntry OBJECT-TYPE
SYNTAX TimeStampUploadConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"TDMoE Port ACR Config Entry"
INDEX { tdmoeTimeStampSlotIndex }
::= { timeStampUploadConfig 1 }
TimeStampUploadConfigEntry ::= SEQUENCE {
tdmoeTimeStampSlotIndex LargeSlotIndex,
tdmoeSrcIP IpAddress,
tdmoeSrcSubnetMask IpAddress,
tdmoeTftpServerIP IpAddress,
tdmoeAcrNum Integer32,
tdmoeEnable INTEGER
}
tdmoeTimeStampSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { timeStampUploadConfigEntry 1 }
tdmoeSrcIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload Source IP."
::= { timeStampUploadConfigEntry 2 }
tdmoeSrcSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload Source Subnet Mask."
::= { timeStampUploadConfigEntry 3 }
tdmoeTftpServerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload TFTP server IP."
::= { timeStampUploadConfigEntry 4 }
tdmoeAcrNum OBJECT-TYPE
SYNTAX Integer32 (1..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload ACR Number."
::= { timeStampUploadConfigEntry 5 }
tdmoeEnable OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
none(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Time Stamp Upload Enable/Disable."
::= { timeStampUploadConfigEntry 6 }
-- end of tdmoe Clock Source Config Table --
toeTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of TDMoE"
::= { tdmoe-card 100 }
--======================================================================--
--======================================================================--
-- 8DBRA-card MIB
--======================================================================--
--======================================================================--
--
-- 8DBRA Configuartion
--
dbraBackupTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraBackupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DBRA Backup table."
::= { oct-dbra-card 1 }
dbraBackupEntry OBJECT-TYPE
SYNTAX DbraBackupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dbra backup table."
INDEX { dbraBackupSlotIndex }
::= { dbraBackupTable 1 }
DbraBackupEntry ::= SEQUENCE {
dbraBackupSlotIndex LargeSlotIndex,
dbraBackupType INTEGER,
dbraSite INTEGER,
dbraMode INTEGER,
dbraForceSwitch INTEGER,
dbraStatus INTEGER
}
dbraBackupSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraBackupEntry 1 }
dbraBackupType OBJECT-TYPE
SYNTAX INTEGER {
no(1),
port-backup(2),
card-backup(3),
dual-host(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA backup mode"
::= { dbraBackupEntry 2 }
dbraSite OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA dual host site"
::= { dbraBackupEntry 3}
dbraMode OBJECT-TYPE
SYNTAX INTEGER {
non-revertible(1),
revertible(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Only use in card backup to determine whether slot changes to working
or stand-by mode "
::= { dbraBackupEntry 4}
dbraForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
no(1),
force(2),
none(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Only use in card backup to force slot changes to working
or stand-by mode "
::= { dbraBackupEntry 5}
dbraStatus OBJECT-TYPE
SYNTAX INTEGER {
working(1),
stand-by(2),
none(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Only show in card-backup to indicate the slot is working
or stand-by STATUS "
::= { dbraBackupEntry 6}
--port map
dbraPortMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraPortMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DBRA Port Map table."
::= { oct-dbra-card 2 }
dbraPortMapEntry OBJECT-TYPE
SYNTAX DbraPortMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dbra port map table."
INDEX { dbraPortMapSlotIndex }
::= { dbraPortMapTable 1 }
DbraPortMapEntry ::= SEQUENCE {
dbraPortMapSlotIndex LargeSlotIndex,
dbraVirtualPort INTEGER,
dbraTsStart INTEGER,
dbraTotalTS INTEGER,
dbraRS232Port INTEGER,
dbraCommand INTEGER
}
dbraPortMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraPortMapEntry 1 }
dbraVirtualPort OBJECT-TYPE
SYNTAX INTEGER {
vp1(1),
vp2(2),
vp3(3),
vp4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA virtual port"
::= { dbraPortMapEntry 2 }
dbraTsStart OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA Time Slot Start range(1-32)"
::= { dbraPortMapEntry 3 }
dbraTotalTS OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA Time Slot Start (1-20)"
::= { dbraPortMapEntry 4}
dbraRS232Port OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA rs232 port"
::= { dbraPortMapEntry 5}
dbraCommand OBJECT-TYPE
SYNTAX INTEGER {
setonly(1),
clear(2),
clearAndset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA rs232 port"
::= { dbraPortMapEntry 6}
-- rs232 config
dbraRs232ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraRs232ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DBRA rs232 config table."
::= { oct-dbra-card 3 }
dbraRs232ConfigEntry OBJECT-TYPE
SYNTAX DbraRs232ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dbra rs232 config table."
INDEX { dbraRs232SlotIndex , dbraRs232PortIndex }
::= { dbraRs232ConfigTable 1 }
DbraRs232ConfigEntry ::= SEQUENCE {
dbraRs232SlotIndex LargeSlotIndex,
dbraRs232PortIndex EightPortID,
dbraRate INTEGER,
dbraInterface INTEGER,
dbraPortMode INTEGER,
dbraUartRate INTEGER,
dbraUartDataLength INTEGER,
dbraUartPCMInv INTEGER
}
dbraRs232SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraRs232ConfigEntry 1 }
dbraRs232PortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dbra port 1-8"
::= { dbraRs232ConfigEntry 2 }
dbraRate OBJECT-TYPE
SYNTAX INTEGER {
r1-2K(1),
r2-4K(2),
r4-8K(3),
r9-6K(4),
r19-2K(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA rate"
::= { dbraRs232ConfigEntry 3 }
dbraInterface OBJECT-TYPE
SYNTAX INTEGER {
db25-RJ(1),
rj-only(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA interface"
::= { dbraRs232ConfigEntry 4 }
dbraPortMode OBJECT-TYPE
SYNTAX INTEGER {
oversample(1),
uart(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA Port Mode"
::= { dbraRs232ConfigEntry 5 }
dbraUartRate OBJECT-TYPE
SYNTAX INTEGER {
r0-6K(1),
r1-2K(2),
r2-4K(3),
r4-8K(4),
r9-6K(5),
r19-2K(6),
r38-4K(7),
r57-6K(8),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA uart mode port Rate"
::= { dbraRs232ConfigEntry 6 }
dbraUartDataLength OBJECT-TYPE
SYNTAX INTEGER {
length-7(1),
length-8(2),
length-9(3),
length-10(4),
length-11(5),
length-12(6),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA uart mode port Data Length"
::= { dbraRs232ConfigEntry 7 }
dbraUartPCMInv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
null(99)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DBRA uart mode port PCM Invert"
::= { dbraRs232ConfigEntry 8 }
-- diagnostic control
dbraDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { oct-dbra-card 4}
dbraDiagControlEntry OBJECT-TYPE
SYNTAX DbraDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { dbraDiagSlotIndex , dbraDiagPortIndex }
::= { dbraDiagControlTable 1 }
DbraDiagControlEntry ::= SEQUENCE {
dbraDiagSlotIndex LargeSlotIndex,
dbraDiagPortIndex EightPortID,
dbrars232Loopback INTEGER
}
dbraDiagSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraDiagControlEntry 1 }
dbraDiagPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dbra port 1-8"
::= { dbraDiagControlEntry 2 }
dbrars232Loopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
to-rs232(2),
to-system(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dbra loopback setup"
::= { dbraDiagControlEntry 3}
-- portmap information
dbraPortMapInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraPortMapInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DBRA Port Map Information table."
::= { oct-dbra-card 5}
dbraPortMapInfoEntry OBJECT-TYPE
SYNTAX DbraPortMapInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the dbra port map info table."
INDEX { dbraPortMapInfoSlotIndex , dbraPortMapInfoPortIndex ,
dbraPortMapTimeSlotIndex }
::= { dbraPortMapInfoTable 1 }
DbraPortMapInfoEntry ::= SEQUENCE {
dbraPortMapInfoSlotIndex LargeSlotIndex,
dbraPortMapInfoPortIndex INTEGER,
dbraPortMapTimeSlotIndex INTEGER,
dbraMapToPort INTEGER
}
dbraPortMapInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraPortMapInfoEntry 1 }
dbraPortMapInfoPortIndex OBJECT-TYPE
SYNTAX INTEGER {
vp1(1),
vp2(2),
vp3(3),
vp4(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA virtual port"
::= { dbraPortMapInfoEntry 2 }
dbraPortMapTimeSlotIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA timeslot index"
::= { dbraPortMapInfoEntry 3 }
dbraMapToPort OBJECT-TYPE
SYNTAX INTEGER {
port-1(1),
port-2(2),
port-3(3),
port-4(4),
port-5(5),
port-6(6),
port-7(7),
port-8(8),
idle (255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA timeslot map to port"
::= { dbraPortMapInfoEntry 4 }
-- command control
dbraCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { oct-dbra-card 6}
dbraCommandControlEntry OBJECT-TYPE
SYNTAX DbraCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { dbraCommandSlotIndex }
::= { dbraCommandControlTable 1 }
DbraCommandControlEntry ::= SEQUENCE {
dbraCommandSlotIndex LargeSlotIndex,
dbraCardReset INTEGER,
dbraLoadDefault INTEGER,
dbraDataMode INTEGER,
dbraDataType INTEGER
}
dbraCommandSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraCommandControlEntry 1 }
dbraCardReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset dbra card"
::= { dbraCommandControlEntry 2 }
dbraLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { dbraCommandControlEntry 3 }
dbraDataMode OBJECT-TYPE
SYNTAX INTEGER {
data-56k(1),
data-64k(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dbra data rate"
::= { dbraCommandControlEntry 4 }
dbraDataType OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
invert(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"dbra data type: normal or invert"
::= { dbraCommandControlEntry 5 }
-- card information
dbraSystemInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbraSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The system information table."
::= { oct-dbra-card 7}
dbraSystemInformationEntry OBJECT-TYPE
SYNTAX DbraSystemInformationEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the system information table."
INDEX { dbraSysInfoSlotIndex }
::= { dbraSystemInformationTable 1 }
DbraSystemInformationEntry ::= SEQUENCE {
dbraSysInfoSlotIndex LargeSlotIndex,
dbraPROMVersion DisplayString,
dbraHardwareVersion DisplayString,
dbraFpgaVersion DisplayString
}
dbraSysInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DBRA slot 1-12"
::= { dbraSystemInformationEntry 1 }
dbraPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" dbra PROM Version"
::= { dbraSystemInformationEntry 2 }
dbraHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" dbra Hardware Version"
::= { dbraSystemInformationEntry 3 }
dbraFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" dbra Fpga Version"
::= { dbraSystemInformationEntry 4 }
dbraTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 8DBRA"
::= { oct-dbra-card 100 }
--======================================================================--
--======================================================================--
-- SOCU/DP Control Table
--======================================================================--
--======================================================================--
socudpConfigControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCU/DP Configuration Control Table"
::= { socudp-card 1 }
socudpConfigControlEntry OBJECT-TYPE
SYNTAX SocudpConfigControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCU/DP configuration control entry"
INDEX { socudpConfigControlIndex }
::= { socudpConfigControlTable 1 }
SocudpConfigControlEntry ::= SEQUENCE {
socudpConfigControlIndex SmallSlotIndex,
socudp-DATA-RATE INTEGER
}
socudpConfigControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpConfigControlEntry 1 }
socudp-DATA-RATE OBJECT-TYPE
SYNTAX INTEGER {
data-rate-2-4K(1),
data-rate-4-8K(2),
data-rate-9-6K(3),
data-rate-19-2K(4),
data-rate-56K(5),
data-rate-64K(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" data rate "
::= { socudpConfigControlEntry 2 }
--
-- Line Status Table
--
socudpLineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCU/DP Line Status Table."
::= { socudp-card 2 }
socudpLineStatusEntry OBJECT-TYPE
SYNTAX SocudpLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of OCU/DP line status table."
INDEX { socudpLineStatusIndex }
::= { socudpLineStatusTable 1 }
SocudpLineStatusEntry ::=SEQUENCE {
socudpLineStatusIndex SmallSlotIndex,
socudpOOS INTEGER,
socudpLOS INTEGER
}
socudpLineStatusIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpLineStatusEntry 1 }
socudpOOS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OCU/DP OOS"
::= { socudpLineStatusEntry 2 }
socudpLOS OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"OCU/DP LOS"
::= { socudpLineStatusEntry 3 }
--
-- Line Diagnostic Control Table
--
socudpLineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpLineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"OCU/DP Diagnostic Control Table."
::= { socudp-card 3 }
socudpLineDiagControlEntry OBJECT-TYPE
SYNTAX SocudpLineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of OCU/DP diagnostic control table."
INDEX { socudpLineDiagControlIndex }
::= { socudpLineDiagControlTable 1 }
SocudpLineDiagControlEntry ::=SEQUENCE {
socudpLineDiagControlIndex SmallSlotIndex,
socudpLoopbackType INTEGER,
socudpPatternStatus INTEGER
}
socudpLineDiagControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpLineDiagControlEntry 1 }
socudpLoopbackType OBJECT-TYPE
SYNTAX INTEGER {
no-loopback(1),
local(2),
payload(3)
-- remote(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCU/DP Loopback Type"
::= { socudpLineDiagControlEntry 2 }
socudpPatternStatus OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OCU/DP pattern Type"
::= { socudpLineDiagControlEntry 3 }
--
-- Alarm Control Table
--
socudpAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The alarm control table."
::= { socudp-card 4 }
socudpAlarmControlEntry OBJECT-TYPE
SYNTAX SocudpAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the OCU/DP alarm control table."
INDEX { socudpAlarmControlIndex }
::= { socudpAlarmControlTable 1 }
SocudpAlarmControlEntry ::=SEQUENCE {
socudpAlarmControlIndex SmallSlotIndex,
socudpOOS-Line INTEGER,
socudpLOS-Line INTEGER
}
socudpAlarmControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpAlarmControlEntry 1 }
socudpOOS-Line OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
major(2),
critical(3),
minor(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"OOS-Line State"
::= { socudpAlarmControlEntry 2 }
socudpLOS-Line OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
major(2),
critical(3),
minor(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS-Line State"
::= { socudpAlarmControlEntry 3 }
--
-- Alarm Queue Table
--
socudpAlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpAlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { socudp-card 5 }
socudpAlarmQueueEntry OBJECT-TYPE
SYNTAX SocudpAlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { socudpPortAlarmQIndex ,
socudpAlarmQueueIndex }
::= { socudpAlarmQueueTable 1 }
SocudpAlarmQueueEntry ::=SEQUENCE {
socudpPortAlarmQIndex SmallSlotIndex,
socudpAlarmQueueIndex INTEGER (1..40),
socudpAlarmQueueString DisplayString (SIZE(0..255))
}
socudpPortAlarmQIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpAlarmQueueEntry 1 }
socudpAlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { socudpAlarmQueueEntry 2 }
socudpAlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { socudpAlarmQueueEntry 3 }
--
-- Command Control Table
--
socudpCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SocudpCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { socudp-card 6 }
socudpCommandControlEntry OBJECT-TYPE
SYNTAX SocudpCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { socudpCommandControlIndex }
::= { socudpCommandControlTable 1 }
SocudpCommandControlEntry ::= SEQUENCE {
socudpCommandControlIndex SmallSlotIndex,
socudpAlarmQueueReset INTEGER,
socudpPortLoadDefault INTEGER,
socudpPortReset INTEGER
}
socudpCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { socudpCommandControlEntry 1 }
socudpAlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { socudpCommandControlEntry 2 }
socudpPortLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default OCU/DP Port"
::= { socudpCommandControlEntry 3 }
socudpPortReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset OCU/DP Port"
::= { socudpCommandControlEntry 4 }
--
-- Test Status Table
--
-- socudpTestStatusTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF SocudpTestStatusEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP Test Status Table."
-- ::= { socudp-card 7 }
--
-- socudpTestStatusEntry OBJECT-TYPE
-- SYNTAX SocudpTestStatusEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "An entry of OCU/DP test status table."
-- INDEX { socudpTestStatusIndex }
-- ::= { socudpTestStatusTable 1 }
--
-- SocudpTestStatusEntry ::=SEQUENCE {
-- socudpTestStatusIndex INTEGER,
-- socudpLOOPBACK INTEGER,
-- socudpPATTERN INTEGER,
-- socudpOCULOOPBACK INTEGER,
-- socudpCSULOOPBACK INTEGER,
-- socudpPOLARITYREVERSE INTEGER
-- }
--
-- socudpTestStatusIndex OBJECT-TYPE
-- SYNTAX INTEGER {
-- slot-A(1),
-- slot-B(2),
-- slot-C(3),
-- slot-D(4),
-- slot-E(5),
-- slot-F(6),
-- slot-H(7),
-- slot-J(8),
-- slot-K(9)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot A-K."
-- ::= { socudpTestStatusEntry 1 }
--
-- socudpLOOPBACK OBJECT-TYPE
-- SYNTAX INTEGER {
-- off(1),
-- local(2),
-- plb(3),
-- remote(4)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP LOOPBACK"
-- ::= { socudpTestStatusEntry 2 }
--
-- socudpPATTERN OBJECT-TYPE
-- SYNTAX INTEGER {
-- off(1),
-- on(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP PATTERN TRANSMITTED"
-- ::= { socudpTestStatusEntry 3 }
--
-- socudpOCULOOPBACK OBJECT-TYPE
-- SYNTAX INTEGER {
-- normal(1),
-- loopback(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP OCU LOOPBACK"
-- ::= { socudpTestStatusEntry 4 }
--
-- socudpCSULOOPBACK OBJECT-TYPE
-- SYNTAX INTEGER {
-- normal(1),
-- loopback(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP CSU LOOPBACK"
-- ::= { socudpTestStatusEntry 5 }
--
-- socudpPOLARITYREVERSE OBJECT-TYPE
-- SYNTAX INTEGER {
-- normal(1),
-- reverse(2)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "OCU/DP POLARITY REVERSE"
-- ::= { socudpTestStatusEntry 6 }
socudpTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of SOCUDP"
::= { socudp-card 100 }
--======================================================================--
--======================================================================--
--======================================================================--
-- octDte card MIB
--======================================================================--
--======================================================================--
--
-- DTE Control Table
--
dte8ConfigCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8ConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Configuration Control Table"
::= { octDte-card 1 }
dte8ConfigCtrlEntry OBJECT-TYPE
SYNTAX Dte8ConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE configuration control entry"
INDEX { dte8ccSlotIndex ,
dte8ccPortIndex }
::= { dte8ConfigCtrlTable 1 }
Dte8ConfigCtrlEntry ::= SEQUENCE {
dte8ccSlotIndex LargeSlotIndex,
dte8ccPortIndex EightPortID,
dte8Interface INTEGER,
dte8DS0Rate INTEGER,
dte8Oversampling INTEGER,
dte8OversamplingRate INTEGER,
dte8SupportDataRate DisplayString,
dte8RTSCTS INTEGER,
dte8DTRDSR INTEGER
}
dte8ccSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8ConfigCtrlEntry 1 }
dte8ccPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8ConfigCtrlEntry 2 }
dte8Interface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2),
rs422(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Interface Type"
::= { dte8ConfigCtrlEntry 3 }
dte8DS0Rate OBJECT-TYPE
SYNTAX INTEGER {
rate64k(1),
rate56k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE DS0 Sampling Rate"
::= { dte8ConfigCtrlEntry 4 }
dte8Oversampling OBJECT-TYPE
SYNTAX INTEGER (1..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE oversampling numver"
::= { dte8ConfigCtrlEntry 5 }
dte8OversamplingRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Rate (Kbps)"
::= { dte8ConfigCtrlEntry 6 }
dte8SupportDataRate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Supported Data Rate"
::= { dte8ConfigCtrlEntry 7 }
dte8RTSCTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE RTS/CTS control"
::= { dte8ConfigCtrlEntry 8 }
dte8DTRDSR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE DTR/DSR control"
::= { dte8ConfigCtrlEntry 9 }
--
-- Alarm Control Table
--
dte8AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE alarm control table."
::= { octDte-card 3 }
dte8AlarmControlEntry OBJECT-TYPE
SYNTAX Dte8AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE alarm control entry."
INDEX { dte8acSlotIndex ,
dte8acPortIndex }
::= { dte8AlarmControlTable 1 }
Dte8AlarmControlEntry ::= SEQUENCE {
dte8acSlotIndex LargeSlotIndex,
dte8acPortIndex EightPortID,
dte8AlarmEnable AlarmSeverity,
dte8AlarmState INTEGER,
dte8AlarmCount INTEGER,
dte8ThrLOLCAlarmEnable AlarmSeverity,
dte8ThrLOLCState INTEGER,
dte8ThrLOLCAlarmCount INTEGER,
dte8ThrLOCHAlarmEnable AlarmSeverity,
dte8ThrLOCHState INTEGER,
dte8ThrLOCHAlarmCount INTEGER,
dte8ThrCREAlarmEnable AlarmSeverity,
dte8ThrCREState INTEGER,
dte8ThrCREAlarmCount INTEGER,
dte8ThrResetCounter INTEGER
}
dte8acSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8AlarmControlEntry 1 }
dte8acPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8AlarmControlEntry 2 }
dte8AlarmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm State"
::= { dte8AlarmControlEntry 3 }
dte8AlarmState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { dte8AlarmControlEntry 4 }
dte8AlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { dte8AlarmControlEntry 5 }
dte8ThrLOLCAlarmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm Loss Of Clock State"
::= { dte8AlarmControlEntry 6 }
dte8ThrLOLCState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State - Loss Of Clock"
::= { dte8AlarmControlEntry 7 }
dte8ThrLOLCAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count - Loss Of Clock "
::= { dte8AlarmControlEntry 8 }
dte8ThrLOCHAlarmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm Loss Of Channel State"
::= { dte8AlarmControlEntry 9 }
dte8ThrLOCHState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State - Loss Of Channel"
::= { dte8AlarmControlEntry 10 }
dte8ThrLOCHAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count - Loss Of Channel "
::= { dte8AlarmControlEntry 11 }
dte8ThrCREAlarmEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm Clock Recovery Error State"
::= { dte8AlarmControlEntry 12 }
dte8ThrCREState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State - Clock Recovery Error"
::= { dte8AlarmControlEntry 13 }
dte8ThrCREAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count - Clock Recovery Error "
::= { dte8AlarmControlEntry 14 }
dte8ThrResetCounter OBJECT-TYPE
SYNTAX INTEGER {
no(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTE Through Clock alarm counter"
::= { dte8AlarmControlEntry 15 }
--
-- Line Diagnostic Control Table
--
dte8DiagCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8DiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Diagnostic Control Table."
::= { octDte-card 4 }
dte8DiagCtrlEntry OBJECT-TYPE
SYNTAX Dte8DiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Diagnostic Control entry."
INDEX { dte8dcSlotIndex ,
dte8dcPortIndex }
::= { dte8DiagCtrlTable 1 }
Dte8DiagCtrlEntry ::= SEQUENCE {
dte8dcSlotIndex LargeSlotIndex,
dte8dcPortIndex EightPortID,
dte8LoopbackType INTEGER,
dte8LoopbackStatus INTEGER
}
dte8dcSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8DiagCtrlEntry 1 }
dte8dcPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8DiagCtrlEntry 2 }
dte8LoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noloopback(1),
toDTEloopback(2),
localloopback(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE Loopback Type"
::= { dte8DiagCtrlEntry 3 }
dte8LoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopbacknotactive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE Loopback Status"
::= { dte8DiagCtrlEntry 4 }
--
-- Command Control Table
--
dte8CommandInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8CommandInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { octDte-card 5 }
dte8CommandInfoEntry OBJECT-TYPE
SYNTAX Dte8CommandInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { dte8ciSlotIndex }
::= { dte8CommandInfoTable 1 }
Dte8CommandInfoEntry ::= SEQUENCE {
dte8ciSlotIndex LargeSlotIndex,
dte8CardReset INTEGER,
dte8CardLoadDefault INTEGER,
dte8FWversion DisplayString,
dte8HWversion DisplayString
}
dte8ciSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8CommandInfoEntry 1 }
dte8CardReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset DTE Port"
::= { dte8CommandInfoEntry 2 }
dte8CardLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
loadDefault(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default DTE Port"
::= { dte8CommandInfoEntry 3 }
dte8FWversion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE FW Version"
::= { dte8CommandInfoEntry 4 }
dte8HWversion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE HW Version"
::= { dte8CommandInfoEntry 5 }
--
-- DTE Status Table
--
dte8StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE status table."
::= { octDte-card 8 }
dte8StatusEntry OBJECT-TYPE
SYNTAX Dte8StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE status entry."
INDEX { dte8stSlotIndex ,
dte8stPortIndex }
::= { dte8StatusTable 1 }
Dte8StatusEntry ::= SEQUENCE {
dte8stSlotIndex LargeSlotIndex,
dte8stPortIndex EightPortID,
dte8RTSloss INTEGER,
dte8RTS INTEGER,
dte8CTS INTEGER,
dte8DSR INTEGER,
dte8DTR INTEGER,
dte8RxBytesCounter Counter,
dte8TxBytesCounter Counter,
dte8ResetCounter INTEGER,
dte8LOLC INTEGER,
dte8LOCH INTEGER,
dte8CRE INTEGER
}
dte8stSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8StatusEntry 1 }
dte8stPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8StatusEntry 2 }
dte8RTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE RTS status "
::= { dte8StatusEntry 3 }
dte8RTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE RTS status "
::= { dte8StatusEntry 4 }
dte8CTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE CTS status "
::= { dte8StatusEntry 5 }
dte8DSR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE DSR status "
::= { dte8StatusEntry 6 }
dte8DTR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deactive(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE DTR status "
::= { dte8StatusEntry 7 }
dte8RxBytesCounter OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Rx bytes counter "
::= { dte8StatusEntry 8 }
dte8TxBytesCounter OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Tx bytes counter "
::= { dte8StatusEntry 9 }
dte8ResetCounter OBJECT-TYPE
SYNTAX INTEGER {
no(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset DTE bytes counter"
::= { dte8StatusEntry 10 }
dte8LOLC OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Loss Of Clock status "
::= { dte8StatusEntry 11 }
dte8LOCH OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Loss Of Channel status "
::= { dte8StatusEntry 12 }
dte8CRE OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE Clock Recovery Error status "
::= { dte8StatusEntry 13 }
--
-- Mode Setup Table
--
dte8ModeSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8ModeSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Card Mode Setup table."
::= { octDte-card 10 }
dte8ModeSetupEntry OBJECT-TYPE
SYNTAX Dte8ModeSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Card Mode Setup entry."
INDEX { dte8ModeSlotIndex }
::= { dte8ModeSetupTable 1 }
Dte8ModeSetupEntry ::= SEQUENCE {
dte8ModeSlotIndex LargeSlotIndex,
dte8CardMode INTEGER
}
dte8ModeSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8ModeSetupEntry 1 }
dte8CardMode OBJECT-TYPE
SYNTAX INTEGER {
oversampling(1),
terminalServer(2),
omnibus(3),
terminalServerAdvanced(5),
omnibusAdvanced(9),
oversamplingAdvanced(17),
throughclock(33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Card Mode"
::= { dte8ModeSetupEntry 2 }
--
-- Omnibus Group Setup Table
--
dte8OmnibusSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8OmnibusSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Group Setup table."
::= { octDte-card 11 }
dte8OmnibusSetupEntry OBJECT-TYPE
SYNTAX Dte8OmnibusSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Group Setup entry."
INDEX { dte8OmnibusSlotIndex ,
dte8OmnibusPortIndex }
::= { dte8OmnibusSetupTable 1 }
Dte8OmnibusSetupEntry ::= SEQUENCE {
dte8OmnibusSlotIndex LargeSlotIndex,
dte8OmnibusPortIndex EightPortID,
dte8OmnibusGroup INTEGER
}
dte8OmnibusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8OmnibusSetupEntry 1 }
dte8OmnibusPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8OmnibusSetupEntry 2 }
dte8OmnibusGroup OBJECT-TYPE
SYNTAX INTEGER {
group1(1),
group2(2),
group3(3),
group4(4),
group5(5),
group6(6),
group7(7),
group8(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Group"
::= { dte8OmnibusSetupEntry 3 }
--
-- Terminal Server DTE Control Table
--
dte8TsDteTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Control Table"
::= { octDte-card 12 }
dte8TsDteEntry OBJECT-TYPE
SYNTAX Dte8TsDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Control entry."
INDEX { dte8TsDteSlotIndex ,
dte8TsDtePortIndex }
::= { dte8TsDteTable 1 }
Dte8TsDteEntry ::= SEQUENCE {
dte8TsDteSlotIndex LargeSlotIndex,
dte8TsDtePortIndex EightPortID,
dte8TsDteInterface INTEGER,
dte8TsDteFrame INTEGER,
dte8TsDteBaudRate INTEGER,
dte8TsDteDataBit INTEGER,
dte8TsDteStopBit INTEGER,
dte8TsDteParityBit INTEGER,
dte8TsDteSwFlowControl INTEGER,
dte8TsDteFlowControlTime INTEGER,
dte8TsDteBufferSize INTEGER,
dte8TsDteBufferTimeout INTEGER,
dte8TsDteDuplex INTEGER,
dte8TsDteIdleDetect INTEGER
}
dte8TsDteSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsDteEntry 1 }
dte8TsDtePortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8TsDteEntry 2 }
dte8TsDteInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2),
rs422(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Interface Type"
::= { dte8TsDteEntry 3 }
dte8TsDteFrame OBJECT-TYPE
SYNTAX INTEGER {
slip(1),
rawdata(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Frame Type"
::= { dte8TsDteEntry 4 }
dte8TsDteBaudRate OBJECT-TYPE
SYNTAX INTEGER {
rate38400(1),
rate19200(2),
rate9600(3),
rate4800(4),
rate2400(5),
rate1200(6),
rate600(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE baud rate"
::= { dte8TsDteEntry 5 }
dte8TsDteDataBit OBJECT-TYPE
SYNTAX INTEGER {
data8bits(1),
data7bits(2),
data6bits(3),
data5bits(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Data bit"
::= { dte8TsDteEntry 6 }
dte8TsDteStopBit OBJECT-TYPE
SYNTAX INTEGER {
stop1bit(1),
stop2bits(2),
stop1dot5bits(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Stop bit"
::= { dte8TsDteEntry 7 }
dte8TsDteParityBit OBJECT-TYPE
SYNTAX INTEGER {
none(1),
even(2),
odd(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Parity check"
::= { dte8TsDteEntry 8 }
dte8TsDteSwFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Software flow control"
::= { dte8TsDteEntry 9 }
dte8TsDteFlowControlTime OBJECT-TYPE
SYNTAX INTEGER (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE flow control time"
::= { dte8TsDteEntry 10 }
dte8TsDteBufferSize OBJECT-TYPE
SYNTAX INTEGER (1..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Buffer Size"
::= { dte8TsDteEntry 11 }
dte8TsDteBufferTimeout OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Buffer Timeout"
::= { dte8TsDteEntry 12 }
dte8TsDteDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Duplex"
::= { dte8TsDteEntry 13 }
dte8TsDteIdleDetect OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE Idle Detect"
::= { dte8TsDteEntry 14 }
--
-- Terminal Server DTE IP Control Table
--
dte8TsDteIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsDteIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Control Table"
::= { octDte-card 13 }
dte8TsDteIpEntry OBJECT-TYPE
SYNTAX Dte8TsDteIpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Control entry."
INDEX { dte8TsDteIpSlotIndex ,
dte8TsDteIpPortIndex }
::= { dte8TsDteIpTable 1 }
Dte8TsDteIpEntry ::= SEQUENCE {
dte8TsDteIpSlotIndex LargeSlotIndex,
dte8TsDteIpPortIndex EightPortID,
dte8TsDteIpRole INTEGER,
dte8TsDteIpLocalIP IpAddress,
dte8TsDteIpSubnetMask IpAddress,
dte8TsDteIpDestinationIP1 IpAddress,
dte8TsDteIpDestinationIP2 IpAddress,
dte8TsDteIpDestinationIP3 IpAddress,
dte8TsDteIpDestinationIP4 IpAddress,
dte8TsDteIpDestinationIP5 IpAddress,
dte8TsDteIpDestinationIP6 IpAddress,
dte8TsDteIpDestinationIP7 IpAddress,
dte8TsDteIpDestinationIP8 IpAddress
}
dte8TsDteIpSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsDteIpEntry 1 }
dte8TsDteIpPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8TsDteIpEntry 2 }
dte8TsDteIpRole OBJECT-TYPE
SYNTAX INTEGER {
server(1),
client(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Role"
::= { dte8TsDteIpEntry 3 }
dte8TsDteIpLocalIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Local IP"
::= { dte8TsDteIpEntry 4 }
dte8TsDteIpSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP SubnetMask"
::= { dte8TsDteIpEntry 5 }
dte8TsDteIpDestinationIP1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 1"
::= { dte8TsDteIpEntry 6 }
dte8TsDteIpDestinationIP2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 2"
::= { dte8TsDteIpEntry 7 }
dte8TsDteIpDestinationIP3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 3"
::= { dte8TsDteIpEntry 8 }
dte8TsDteIpDestinationIP4 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 4"
::= { dte8TsDteIpEntry 9 }
dte8TsDteIpDestinationIP5 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 5"
::= { dte8TsDteIpEntry 10 }
dte8TsDteIpDestinationIP6 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 6"
::= { dte8TsDteIpEntry 11 }
dte8TsDteIpDestinationIP7 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 7"
::= { dte8TsDteIpEntry 12 }
dte8TsDteIpDestinationIP8 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server DTE IP Destination IP 8"
::= { dte8TsDteIpEntry 13 }
--
-- Terminal Server Router Wan Setup Table
--
dte8TsWanTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsWanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan Setup table."
::= { octDte-card 14 }
dte8TsWanEntry OBJECT-TYPE
SYNTAX Dte8TsWanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan Setup entry."
INDEX { dte8TsWanSlotIndex ,
dte8TsWanNI }
::= { dte8TsWanTable 1 }
Dte8TsWanEntry ::= SEQUENCE {
dte8TsWanSlotIndex LargeSlotIndex,
dte8TsWanNI INTEGER,
dte8TsWanIPAddress IpAddress,
dte8TsWanSubnetMask IpAddress,
dte8TsWanFrame INTEGER,
dte8TsWanRip1 INTEGER,
dte8TsWanRip2 INTEGER
}
dte8TsWanSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsWanEntry 1 }
dte8TsWanNI OBJECT-TYPE
SYNTAX INTEGER {
wan-1(1),
wan-2(2),
wan-3(3),
wan-4(4),
wan-5(5),
wan-6(6),
wan-7(7),
wan-8(8),
wan-9(9),
wan-10(10),
wan-11(11),
wan-12(12),
wan-13(13),
wan-14(14),
wan-15(15),
wan-16(16),
wan-17(17),
wan-18(18),
wan-19(19),
wan-20(20),
wan-21(21),
wan-22(22),
wan-23(23),
wan-24(24),
wan-25(25),
wan-26(26),
wan-27(27),
wan-28(28),
wan-29(29),
wan-30(30),
wan-31(31),
wan-32(32),
wan-33(33),
wan-34(34),
wan-35(35),
wan-36(36),
wan-37(37),
wan-38(38),
wan-39(39),
wan-40(40),
wan-41(41),
wan-42(42),
wan-43(43),
wan-44(44),
wan-45(45),
wan-46(46),
wan-47(47),
wan-48(48),
wan-49(49),
wan-50(50),
wan-51(51),
wan-52(52),
wan-53(53),
wan-54(54),
wan-55(55),
wan-56(56),
wan-57(57),
wan-58(58),
wan-59(59),
wan-60(60),
wan-61(61),
wan-62(62),
wan-63(63),
wan-64(64)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan Index"
::= { dte8TsWanEntry 2 }
dte8TsWanIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan IpAddress"
::= { dte8TsWanEntry 3 }
dte8TsWanSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan Subnet Mask"
::= { dte8TsWanEntry 4 }
dte8TsWanFrame OBJECT-TYPE
SYNTAX INTEGER {
hdlc(1),
ppp(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan Frame"
::= { dte8TsWanEntry 5 }
dte8TsWanRip1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan RIP_I"
::= { dte8TsWanEntry 6 }
dte8TsWanRip2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Router Wan RIP_II"
::= { dte8TsWanEntry 7 }
--
-- Terminal Server Static Router Display Table
--
dte8TsStRouteDispTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsStRouteDispEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display table."
::= { octDte-card 15 }
dte8TsStRouteDispEntry OBJECT-TYPE
SYNTAX Dte8TsStRouteDispEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display entry."
INDEX { dte8TsStRouteDispSlotIndex ,
dte8TsStRouteDispIndex }
::= { dte8TsStRouteDispTable 1 }
Dte8TsStRouteDispEntry ::= SEQUENCE {
dte8TsStRouteDispSlotIndex LargeSlotIndex,
dte8TsStRouteDispIndex INTEGER,
dte8TsStRouteDispNetAddress IpAddress,
dte8TsStRouteDispNetMask IpAddress,
dte8TsStRouteDispGatewayIP IpAddress,
dte8TsStRouteDispNIAddress IpAddress,
dte8TsStRouteDispMetric INTEGER
}
dte8TsStRouteDispSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsStRouteDispEntry 1 }
dte8TsStRouteDispIndex OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display Index(1-64)"
::= { dte8TsStRouteDispEntry 2 }
dte8TsStRouteDispNetAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display Net Address"
::= { dte8TsStRouteDispEntry 3 }
dte8TsStRouteDispNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display Net Mask"
::= { dte8TsStRouteDispEntry 4 }
dte8TsStRouteDispGatewayIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display Gateway Address"
::= { dte8TsStRouteDispEntry 5 }
dte8TsStRouteDispNIAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display NI Address"
::= { dte8TsStRouteDispEntry 6 }
dte8TsStRouteDispMetric OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Display Metric"
::= { dte8TsStRouteDispEntry 7 }
--
-- Terminal Server Static Router Add Delete Table
--
dte8TsStRouteAddDelTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsStRouteAddDelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete table."
::= { octDte-card 16 }
dte8TsStRouteAddDelEntry OBJECT-TYPE
SYNTAX Dte8TsStRouteAddDelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete entry."
INDEX { dte8TsStRouteAddDelSlotIndex }
::= { dte8TsStRouteAddDelTable 1 }
Dte8TsStRouteAddDelEntry ::= SEQUENCE {
dte8TsStRouteAddDelSlotIndex LargeSlotIndex,
dte8TsStRouteAddDelNetAddress IpAddress,
dte8TsStRouteAddDelNetMask IpAddress,
dte8TsStRouteAddDelGatewayIP IpAddress,
dte8TsStRouteAddDelNIAddress IpAddress,
dte8TsStRouteAddDelMetric INTEGER,
dte8TsStRouteAddDelCmd INTEGER
}
dte8TsStRouteAddDelSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsStRouteAddDelEntry 1 }
dte8TsStRouteAddDelNetAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete Net Address"
::= { dte8TsStRouteAddDelEntry 2 }
dte8TsStRouteAddDelNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete Net Mask"
::= { dte8TsStRouteAddDelEntry 3 }
dte8TsStRouteAddDelGatewayIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete Gateway Address"
::= { dte8TsStRouteAddDelEntry 4 }
dte8TsStRouteAddDelNIAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete NI Address"
::= { dte8TsStRouteAddDelEntry 5 }
dte8TsStRouteAddDelMetric OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete Metric"
::= { dte8TsStRouteAddDelEntry 6 }
dte8TsStRouteAddDelCmd OBJECT-TYPE
SYNTAX INTEGER {
noAction(1),
add(2),
delete(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Static Router Add Delete Command"
::= { dte8TsStRouteAddDelEntry 7 }
--
-- Terminal Server Map Setup Table
--
dte8TsMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Map Setup table."
::= { octDte-card 17 }
dte8TsMapEntry OBJECT-TYPE
SYNTAX Dte8TsMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Map Setup entry."
INDEX { dte8TsMapSlotIndex ,
dte8TsMapVirtualPort ,
dte8TsMapTSIndex }
::= { dte8TsMapTable 1 }
Dte8TsMapEntry ::= SEQUENCE {
dte8TsMapSlotIndex LargeSlotIndex,
dte8TsMapVirtualPort INTEGER,
dte8TsMapTSIndex TimeslotID,
dte8TsMapOption INTEGER
}
dte8TsMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsMapEntry 1 }
dte8TsMapVirtualPort OBJECT-TYPE
SYNTAX INTEGER {
virtualPort1(1),
virtualPort2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Map Virtual Port"
::= { dte8TsMapEntry 2 }
dte8TsMapTSIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Map Time Slot"
::= { dte8TsMapEntry 3 }
dte8TsMapOption OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
wan1(2),
wan2(3),
wan3(4),
wan4(5),
wan5(6),
wan6(7),
wan7(8),
wan8(9),
wan9(10),
wan10(11),
wan11(12),
wan12(13),
wan13(14),
wan14(15),
wan15(16),
wan16(17),
wan17(18),
wan18(19),
wan19(20),
wan20(21),
wan21(22),
wan22(23),
wan23(24),
wan24(25),
wan25(26),
wan26(27),
wan27(28),
wan28(29),
wan29(30),
wan30(31),
wan31(32),
wan32(33),
wan33(34),
wan34(35),
wan35(36),
wan36(37),
wan37(38),
wan38(39),
wan39(40),
wan40(41),
wan41(42),
wan42(43),
wan43(44),
wan44(45),
wan45(46),
wan46(47),
wan47(48),
wan48(49),
wan49(50),
wan50(51),
wan51(52),
wan52(53),
wan53(54),
wan54(55),
wan55(56),
wan56(57),
wan57(58),
wan58(59),
wan59(60),
wan60(61),
wan61(62),
wan62(63),
wan63(64),
wan64(65)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Terminal Server Map Option"
::= { dte8TsMapEntry 4 }
--
-- Omnibus DTE Control Table
--
dte8OmDteTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8OmDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Setup Table"
::= { octDte-card 21 }
dte8OmDteEntry OBJECT-TYPE
SYNTAX Dte8OmDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Setup entry."
INDEX { dte8OmDteSlotIndex ,
dte8OmDtePortIndex }
::= { dte8OmDteTable 1 }
Dte8OmDteEntry ::= SEQUENCE {
dte8OmDteSlotIndex LargeSlotIndex,
dte8OmDtePortIndex EightPortID,
dte8OmDteInterface INTEGER,
dte8OmDteDataID INTEGER,
dte8OmDteBaudRate INTEGER,
dte8OmDteDataBit INTEGER,
dte8OmDteStopBit INTEGER,
dte8OmDteParityBit INTEGER,
dte8OmDteRole INTEGER,
dte8OmDteHwFlowControl INTEGER,
dte8OmDteONTimer INTEGER,
dte8OmDteOFFTimer INTEGER,
dte8OmDteBufferSize INTEGER,
dte8OmDteBufferTimeout INTEGER,
dte8OmDteDuplex INTEGER,
dte8OmDteIdleDetect INTEGER
}
dte8OmDteSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8OmDteEntry 1 }
dte8OmDtePortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8OmDteEntry 2 }
dte8OmDteInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2),
rs422(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Interface Type"
::= { dte8OmDteEntry 3 }
dte8OmDteDataID OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Data ID"
::= { dte8OmDteEntry 4 }
dte8OmDteBaudRate OBJECT-TYPE
SYNTAX INTEGER {
rate38400(1),
rate19200(2),
rate9600(3),
rate4800(4),
rate2400(5),
rate1200(6),
rate600(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE baud rate"
::= { dte8OmDteEntry 5 }
dte8OmDteDataBit OBJECT-TYPE
SYNTAX INTEGER {
data8bits(1),
data7bits(2),
data6bits(3),
data5bits(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Data Bit"
::= { dte8OmDteEntry 6 }
dte8OmDteStopBit OBJECT-TYPE
SYNTAX INTEGER {
stop1bit(1),
stop2bits(2),
stop1dot5bits(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Stop Bit"
::= { dte8OmDteEntry 7 }
dte8OmDteParityBit OBJECT-TYPE
SYNTAX INTEGER {
none(1),
even(2),
odd(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Parity check"
::= { dte8OmDteEntry 8 }
dte8OmDteRole OBJECT-TYPE
SYNTAX INTEGER {
slave(1),
master(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Role"
::= { dte8OmDteEntry 9 }
dte8OmDteHwFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Hardware flow control"
::= { dte8OmDteEntry 10 }
dte8OmDteONTimer OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE ON Timer"
::= { dte8OmDteEntry 11 }
dte8OmDteOFFTimer OBJECT-TYPE
SYNTAX INTEGER (0..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE OFF Timer"
::= { dte8OmDteEntry 12 }
dte8OmDteBufferSize OBJECT-TYPE
SYNTAX INTEGER (1..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Buffer Size"
::= { dte8OmDteEntry 13 }
dte8OmDteBufferTimeout OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Buffer Timeout"
::= { dte8OmDteEntry 14 }
dte8OmDteDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Duplex"
::= { dte8OmDteEntry 15 }
dte8OmDteIdleDetect OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus DTE Idle Detect"
::= { dte8OmDteEntry 16 }
--
-- Omnibus Map Table
--
dte8OmMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8OmMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Map table."
::= { octDte-card 22 }
dte8OmMapEntry OBJECT-TYPE
SYNTAX Dte8OmMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Map entry."
INDEX { dte8OmMapSlotIndex ,
dte8OmMapVirtualPort ,
dte8OmMapTSIndex }
::= { dte8OmMapTable 1 }
Dte8OmMapEntry ::= SEQUENCE {
dte8OmMapSlotIndex LargeSlotIndex,
dte8OmMapVirtualPort INTEGER,
dte8OmMapTSIndex TimeslotID,
dte8OmMapOption INTEGER
}
dte8OmMapSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8OmMapEntry 1 }
dte8OmMapVirtualPort OBJECT-TYPE
SYNTAX INTEGER {
virtualPort1(1),
virtualPort2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Map Virtual Port"
::= { dte8OmMapEntry 2 }
dte8OmMapTSIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Map Time Slot"
::= { dte8OmMapEntry 3 }
dte8OmMapOption OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
bg1west(2),
bg2west(3),
bg3west(4),
bg4west(5),
bg5west(6),
bg6west(7),
bg7west(8),
bg8west(9),
bg1east(10),
bg2east(11),
bg3east(12),
bg4east(13),
bg5east(14),
bg6east(15),
bg7east(16),
bg8east(17)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Omnibus Map Option"
::= { dte8OmMapEntry 4 }
octDteTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 8UDTE"
::= { octDte-card 100 }
--
-- Oversampling advanced DTE Control Table
--
dte8OvaConfigCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8OvaConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced Configuration Control Table"
::= { octDte-card 30 }
dte8OvaConfigCtrlEntry OBJECT-TYPE
SYNTAX Dte8OvaConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced configuration control entry"
INDEX { dte8OvaccSlotIndex , dte8OvaccPortIndex }
::= { dte8OvaConfigCtrlTable 1 }
Dte8OvaConfigCtrlEntry ::= SEQUENCE {
dte8OvaccSlotIndex LargeSlotIndex,
dte8OvaccPortIndex EightPortID,
dte8OvaInterface INTEGER,
dte8OvaDS0Rate INTEGER,
dte8OvaOversampling INTEGER,
dte8OvaOversamplingRate INTEGER,
dte8OvaSupportDataRate DisplayString,
dte8OvaDteBaudRate INTEGER,
dte8OvaDteDataBit INTEGER,
dte8OvaDteStopBit INTEGER,
dte8OvaDteParityBit INTEGER,
dte8OvaDteDuplex INTEGER,
dte8OvaDteIdleDetect INTEGER,
dte8OvaRTSCTS INTEGER,
dte8OvaDTRDSR INTEGER
}
dte8OvaccSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8OvaConfigCtrlEntry 1 }
dte8OvaccPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8OvaConfigCtrlEntry 2 }
dte8OvaInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs485(2),
rs422(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced Interface Type"
::= { dte8OvaConfigCtrlEntry 3 }
dte8OvaDS0Rate OBJECT-TYPE
SYNTAX INTEGER {
rate64k(1),
rate56k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DS0 Sampling Rate"
::= { dte8OvaConfigCtrlEntry 4 }
dte8OvaOversampling OBJECT-TYPE
SYNTAX INTEGER (1..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced oversampling numver"
::= { dte8OvaConfigCtrlEntry 5 }
dte8OvaOversamplingRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced Oversampling Rate (Kbps)"
::= { dte8OvaConfigCtrlEntry 6 }
dte8OvaSupportDataRate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced Supported Data Rate"
::= { dte8OvaConfigCtrlEntry 7 }
dte8OvaDteBaudRate OBJECT-TYPE
SYNTAX INTEGER {
rate110(1),
rate150(2),
rate200(3),
rate300(4),
rate600(5),
rate1200(6),
rate2400(7),
rate4800(8),
rate9600(9),
rate19200(10),
rate28800(11),
rate38400(12),
rate57600(13),
rate115200(14),
rate128000(15)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTE baud rate"
::= { dte8OvaConfigCtrlEntry 8 }
dte8OvaDteDataBit OBJECT-TYPE
SYNTAX INTEGER {
data8bits(1),
data7bits(2),
data6bits(3),
data5bits(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTE Data bit"
::= { dte8OvaConfigCtrlEntry 9 }
dte8OvaDteStopBit OBJECT-TYPE
SYNTAX INTEGER {
stop1bit(1),
stop2bits(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTEOversampling Advanced DTE Stop bit"
::= { dte8OvaConfigCtrlEntry 10 }
dte8OvaDteParityBit OBJECT-TYPE
SYNTAX INTEGER {
none(1),
even(2),
odd(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTE Parity check"
::= { dte8OvaConfigCtrlEntry 11 }
dte8OvaDteDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTE Duplex"
::= { dte8OvaConfigCtrlEntry 12 }
dte8OvaDteIdleDetect OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTE Idle Detect"
::= { dte8OvaConfigCtrlEntry 13 }
dte8OvaRTSCTS OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced RTS/CTS control"
::= { dte8OvaConfigCtrlEntry 14 }
dte8OvaDTRDSR OBJECT-TYPE
SYNTAX INTEGER {
active(1),
permanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Oversampling Advanced DTR/DSR control"
::= { dte8OvaConfigCtrlEntry 15 }
--
-- Through Clock DTE Control Table
--
dte8ThrConfigCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8ThrConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock Configuration Control Table"
::= { octDte-card 50 }
dte8ThrConfigCtrlEntry OBJECT-TYPE
SYNTAX Dte8ThrConfigCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock configuration control entry"
INDEX { dte8ThrccSlotIndex , dte8ThrccPortIndex }
::= { dte8ThrConfigCtrlTable 1 }
Dte8ThrConfigCtrlEntry ::= SEQUENCE {
dte8ThrccSlotIndex LargeSlotIndex,
dte8ThrccPortIndex EightPortID,
dte8ThrInterface INTEGER,
dte8ThrBaudRate INTEGER,
dte8ThrClkInputInverse INTEGER,
dte8ThrClkOutputInverse INTEGER,
dte8ThrPCMDataInverse INTEGER,
dte8ThrSyncMode INTEGER
}
dte8ThrccSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8ThrConfigCtrlEntry 1 }
dte8ThrccPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8ThrConfigCtrlEntry 2 }
dte8ThrInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1)
-- rs485(2),
-- rs422(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock Interface Type"
::= { dte8ThrConfigCtrlEntry 3 }
dte8ThrBaudRate OBJECT-TYPE
SYNTAX INTEGER (1..38400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock baud rate"
::= { dte8ThrConfigCtrlEntry 4 }
dte8ThrClkInputInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock clock input inverse"
::= { dte8ThrConfigCtrlEntry 5 }
dte8ThrClkOutputInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock clock output inverse"
::= { dte8ThrConfigCtrlEntry 6 }
dte8ThrPCMDataInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock PCM data inverse"
::= { dte8ThrConfigCtrlEntry 7 }
dte8ThrSyncMode OBJECT-TYPE
SYNTAX INTEGER {
through(1),
sync(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"8UDTE Through Clock sync mode"
::= { dte8ThrConfigCtrlEntry 8 }
--
-- DTE8 TS Alarm Control Table
--
dte8TsAlarmCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte8TsAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE TS alarm control table."
::= { octDte-card 51 }
dte8TsAlarmCtrlEntry OBJECT-TYPE
SYNTAX Dte8TsAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"8UDTE TS alarm control entry."
INDEX { dte8TsACSlotIndex ,
dte8TsACPortIndex }
::= { dte8TsAlarmCtrlTable 1 }
Dte8TsAlarmCtrlEntry ::= SEQUENCE {
dte8TsACSlotIndex LargeSlotIndex,
dte8TsACPortIndex EightPortID,
dte8TsACConnEnable AlarmSeverity,
dte8TsACConnCount INTEGER,
dte8TsACDisConnEnable AlarmSeverity,
dte8TsACDisConnCount INTEGER
}
dte8TsACSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { dte8TsAlarmCtrlEntry 1 }
dte8TsACPortIndex OBJECT-TYPE
SYNTAX EightPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1~8"
::= { dte8TsAlarmCtrlEntry 2 }
dte8TsACConnEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm TERM-CONN"
::= { dte8TsAlarmCtrlEntry 3 }
dte8TsACConnCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count - TERM-CONN "
::= { dte8TsAlarmCtrlEntry 4 }
dte8TsACDisConnEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE-Alarm TERM-DISCONN"
::= { dte8TsAlarmCtrlEntry 5 }
dte8TsACDisConnCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count - TERM-DISCONN "
::= { dte8TsAlarmCtrlEntry 6 }
--======================================================================--
--============================================================================--
--============================================================================--
-- ECA card MIB
--============================================================================--
--============================================================================--
EcaPortID ::= INTEGER {
ep-1(1),
ep-2(2),
cp-1(3),
cp-2(4)
}
--
-- u/a law Format Table
--
ecaModeConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF EcaModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ECA law format config table."
::= { eca-card 1 }
ecaModeConfigEntry OBJECT-TYPE
SYNTAX EcaModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Format Mode Table."
INDEX { ecaModeConfigSlotIndex , ecaModeConfigPortIndex }
::= { ecaModeConfigTable 1 }
EcaModeConfigEntry ::= SEQUENCE {
ecaModeConfigSlotIndex SmallSlotIndex,
ecaModeConfigPortIndex EcaPortID,
ecaModeConfigFormat INTEGER
}
ecaModeConfigSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { ecaModeConfigEntry 1 }
ecaModeConfigPortIndex OBJECT-TYPE
SYNTAX EcaPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Port index, total 2 port."
::= { ecaModeConfigEntry 2 }
ecaModeConfigFormat OBJECT-TYPE
SYNTAX INTEGER {
u-Law(1),
a-Law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Format Mode."
::= { ecaModeConfigEntry 3 }
--
-- Echo Cancellation Table
--
ecaCancellationCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF EcaCancellationCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Echo Cancellation Config table."
::= { eca-card 2 }
ecaCancellationCfgEntry OBJECT-TYPE
SYNTAX EcaCancellationCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of Echo Cancellation table."
INDEX { ecaCancellationConfigSlotIndex ,
ecaCancellationConfigPortIndex ,
ecaCancellationConfigTsIndex }
::= { ecaCancellationCfgTable 1 }
EcaCancellationCfgEntry ::= SEQUENCE {
ecaCancellationConfigSlotIndex SmallSlotIndex,
ecaCancellationConfigPortIndex EcaPortID,
ecaCancellationConfigTsIndex TimeslotID,
ecaCancellationConfigMode INTEGER
}
ecaCancellationConfigSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { ecaCancellationCfgEntry 1 }
ecaCancellationConfigPortIndex OBJECT-TYPE
SYNTAX EcaPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Port index, total 2 port."
::= { ecaCancellationCfgEntry 2 }
ecaCancellationConfigTsIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { ecaCancellationCfgEntry 3 }
ecaCancellationConfigMode OBJECT-TYPE
SYNTAX INTEGER {
bypass(1),
s64msUni-D(2),
s64msBi-D(3),
s128ms(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Echo Cancellation mode."
::= { ecaCancellationCfgEntry 4 }
--
-- ECA status table
--
ecaStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EcaStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Echo canceller card status table."
::= { eca-card 3 }
ecaStatusEntry OBJECT-TYPE
SYNTAX EcaStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of Echo canceller card status."
INDEX { ecaStatusSlotIndex , ecaStatusPortIndex , ecaStatusTsIndex }
::= { ecaStatusTable 1 }
EcaStatusEntry ::= SEQUENCE {
ecaStatusSlotIndex SmallSlotIndex,
ecaStatusPortIndex EcaPortID,
ecaStatusTsIndex TimeslotID,
ecaStatustoneDetectorStatus INTEGER,
ecaStatusnarrowBandStatus INTEGER
}
ecaStatusSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { ecaStatusEntry 1 }
ecaStatusPortIndex OBJECT-TYPE
SYNTAX EcaPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Port index, total 2 port."
::= { ecaStatusEntry 2 }
ecaStatusTsIndex OBJECT-TYPE
SYNTAX TimeslotID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time slot index."
::= { ecaStatusEntry 3 }
ecaStatustoneDetectorStatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tone Detector status."
::= { ecaStatusEntry 4 }
ecaStatusnarrowBandStatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Narrow Band Signal Detector status."
::= { ecaStatusEntry 5 }
--
-- ECA Card Control Table
--
ecaCardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF EcaCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ECA Card control table."
::= { eca-card 4 }
ecaCardControlEntry OBJECT-TYPE
SYNTAX EcaCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ECA Card control table."
INDEX { ecaCardIndex }
::= { ecaCardControlTable 1 }
EcaCardControlEntry ::= SEQUENCE {
ecaCardIndex SmallSlotIndex,
ecaReset INTEGER,
ecaLoadDefault INTEGER
}
ecaCardIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { ecaCardControlEntry 1 }
ecaReset OBJECT-TYPE
SYNTAX INTEGER {
no(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset eca card"
::= { ecaCardControlEntry 2 }
ecaLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { ecaCardControlEntry 3 }
--
-- ECA System Information Table
--
ecaSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EcaSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ECA system information table."
::= { eca-card 5}
ecaSystemInfoEntry OBJECT-TYPE
SYNTAX EcaSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ECA system information table."
INDEX { ecaSystemInfoSlotIndex }
::= { ecaSystemInfoTable 1 }
EcaSystemInfoEntry ::= SEQUENCE {
ecaSystemInfoSlotIndex SmallSlotIndex,
ecaSystemInfoPROMVersion DisplayString,
ecaSystemInfoHardwareVersion DisplayString,
ecaSystemInfoFpgaVersion DisplayString,
ecaSystemInfoBank1Version DisplayString,
ecaSystemInfoBank2Version DisplayString,
ecaSystemInfoActiveBank INTEGER
}
ecaSystemInfoSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { ecaSystemInfoEntry 1 }
ecaSystemInfoPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" eca PROM Version"
::= { ecaSystemInfoEntry 2 }
ecaSystemInfoHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" eca Hardware Version"
::= { ecaSystemInfoEntry 3 }
ecaSystemInfoFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { ecaSystemInfoEntry 4 }
ecaSystemInfoBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { ecaSystemInfoEntry 5 }
ecaSystemInfoBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { ecaSystemInfoEntry 6}
ecaSystemInfoActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { ecaSystemInfoEntry 7 }
ecaTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of ECA"
::= { eca-card 100 }
--======================================================================--
--======================================================================--
-- 6rs232a-card MIB
--======================================================================--
--======================================================================--
--
-- 6RS232A Configuration
--
rs232aConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Rs232a Interface Configuration table."
::= { rs232a-card 1 }
rs232aConfigEntry OBJECT-TYPE
SYNTAX Rs232aConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Rs232a Configuration table."
INDEX { rsCfgSlotIndex , rsCfgPortIndex }
::= { rs232aConfigTable 1 }
Rs232aConfigEntry ::= SEQUENCE {
rsCfgSlotIndex LargeSlotIndex,
rsCfgPortIndex SixPortID,
rsCfgMux INTEGER,
rsCfgSyncMode INTEGER,
rsCfgRate INTEGER,
rsCfgBitPosition INTEGER,
rsCfgClockPolarity INTEGER,
rsCfgDataPolarity INTEGER,
rsCfgRTS INTEGER,
rsCfgTTM INTEGER,
rsCfgInterface INTEGER,
rsCfgBitPosition0Used INTEGER,
rsCfgBitPosition1Used INTEGER,
rsCfgBitPosition2Used INTEGER,
rsCfgBitPosition3Used INTEGER,
rsCfgBitPosition4Used INTEGER,
rsCfgBitPosition5Used INTEGER,
rsCfgBitPosition6Used INTEGER,
rsCfgBitPosition7Used INTEGER,
rsCfgWarrning DisplayString
}
rsCfgSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aConfigEntry 1 }
rsCfgPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { rs232aConfigEntry 2 }
rsCfgMux OBJECT-TYPE
SYNTAX INTEGER {
nonMux(1),
mux(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a MUX mode"
::= { rs232aConfigEntry 3 }
rsCfgSyncMode OBJECT-TYPE
SYNTAX INTEGER {
async8(1),
async9(2),
async10(3),
async11(4),
async12(5),
sync(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Sync mode"
::= { rs232aConfigEntry 4 }
rsCfgRate OBJECT-TYPE
SYNTAX INTEGER {
r0-6K(1),
r1-2K(2),
r2-4K(3),
r4-8K(4),
r9-6K(5),
r19-2K(6),
r38-4K(7),
r48K(8),
r64K(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Base Rate"
::= { rs232aConfigEntry 5 }
rsCfgBitPosition OBJECT-TYPE
SYNTAX INTEGER {
position-0(1),
position-1(2),
position-2(3),
position-3(4),
position-4(5),
position-5(6),
position-6(7),
position-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Bit position"
::= { rs232aConfigEntry 6 }
rsCfgClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Clock Polarity"
::= { rs232aConfigEntry 7 }
rsCfgDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Data Polarity"
::= { rs232aConfigEntry 8 }
rsCfgRTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a RTS Mode"
::= { rs232aConfigEntry 9 }
rsCfgTTM OBJECT-TYPE
SYNTAX INTEGER {
ttmOff(1),
ttmOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a TTM Mode"
::= { rs232aConfigEntry 10 }
rsCfgInterface OBJECT-TYPE
SYNTAX INTEGER {
db44(1),
rj45(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Interface Type"
::= { rs232aConfigEntry 11 }
rsCfgBitPosition0Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 0 Stream Position Used"
::= { rs232aConfigEntry 12 }
rsCfgBitPosition1Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 1 Stream Position Used"
::= { rs232aConfigEntry 13 }
rsCfgBitPosition2Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 2 Stream Position Used"
::= { rs232aConfigEntry 14 }
rsCfgBitPosition3Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 3 Stream Position Used"
::= { rs232aConfigEntry 15 }
rsCfgBitPosition4Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 4 Stream Position Used"
::= { rs232aConfigEntry 16 }
rsCfgBitPosition5Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 5 Stream Position Used"
::= { rs232aConfigEntry 17 }
rsCfgBitPosition6Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 6 Stream Position Used"
::= { rs232aConfigEntry 18 }
rsCfgBitPosition7Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a Bits 7 Stream Position Used"
::= { rs232aConfigEntry 19 }
rsCfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a map setup warning"
::= { rs232aConfigEntry 20 }
--
-- Rs232a Status
--
rs232aStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Rs232a Status table."
::= { rs232a-card 2 }
rs232aStatusEntry OBJECT-TYPE
SYNTAX Rs232aStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Rs232a Status table."
INDEX { rs232aStatusSlotIndex , rs232aStatusPortIndex }
::= { rs232aStatusTable 1 }
Rs232aStatusEntry ::= SEQUENCE {
rs232aStatusSlotIndex LargeSlotIndex,
rs232aStatusPortIndex SixPortID,
rs232aStatusS1 INTEGER,
rs232aStatusS3 INTEGER,
rs232aStatusS4 INTEGER,
rs232aStatusS6 INTEGER,
rs232aStatusS8 INTEGER,
rs232aStatusS9 INTEGER,
rs232aStatusE4 INTEGER,
rs232aStatusE5 INTEGER,
rs232aStatusE6 INTEGER,
rs232aStatusX INTEGER,
rs232aStatusDteCTS INTEGER,
rs232aStatusDteDCD INTEGER,
rs232aStatusRTSloss INTEGER,
rs232aStatusEXTCLKloss INTEGER,
rs232aStatusDSRstatus INTEGER,
rs232aStatusCTSstatus INTEGER,
rs232aStatusDCDstatus INTEGER,
rs232aStatusDTRstatus INTEGER,
rs232aStatusRTSstatus INTEGER,
rs232aStatusRemoteAlarm INTEGER,
rs232aStatusRemoteS1 INTEGER,
rs232aStatusRemoteS3 INTEGER,
rs232aStatusRemoteS4 INTEGER,
rs232aStatusRemoteS6 INTEGER,
rs232aStatusRemoteS8 INTEGER,
rs232aStatusRemoteS9 INTEGER,
rs232aStatusRemoteE4 INTEGER,
rs232aStatusRemoteE5 INTEGER,
rs232aStatusRemoteE6 INTEGER,
rs232aStatusRemoteX INTEGER
}
rs232aStatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aStatusEntry 1 }
rs232aStatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { rs232aStatusEntry 2 }
rs232aStatusS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S1"
::= { rs232aStatusEntry 3 }
rs232aStatusS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S3"
::= { rs232aStatusEntry 4 }
rs232aStatusS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S4"
::= { rs232aStatusEntry 5 }
rs232aStatusS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S6"
::= { rs232aStatusEntry 6 }
rs232aStatusS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S8"
::= { rs232aStatusEntry 7 }
rs232aStatusS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit S9"
::= { rs232aStatusEntry 8 }
rs232aStatusE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit E4"
::= { rs232aStatusEntry 9 }
rs232aStatusE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit E5"
::= { rs232aStatusEntry 10 }
rs232aStatusE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit E6"
::= { rs232aStatusEntry 11 }
rs232aStatusX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rtswithFrameSYNC(12),
frameSYNC(13),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit X"
::= { rs232aStatusEntry 12 }
rs232aStatusDteCTS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit DTE CTS"
::= { rs232aStatusEntry 13 }
rs232aStatusDteDCD OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Status bit DTE DCD"
::= { rs232aStatusEntry 14 }
rs232aStatusRTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a RTS loss"
::= { rs232aStatusEntry 15 }
rs232aStatusEXTCLKloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a EXT-CLK loss"
::= { rs232aStatusEntry 16 }
rs232aStatusDSRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a DSR"
::= { rs232aStatusEntry 17 }
rs232aStatusCTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a CTS"
::= { rs232aStatusEntry 18 }
rs232aStatusDCDstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a DCD"
::= { rs232aStatusEntry 19 }
rs232aStatusDTRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a DTR"
::= { rs232aStatusEntry 20 }
rs232aStatusRTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a RTS"
::= { rs232aStatusEntry 21 }
rs232aStatusRemoteAlarm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a RTS"
::= { rs232aStatusEntry 22 }
rs232aStatusRemoteS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S1"
::= { rs232aStatusEntry 23 }
rs232aStatusRemoteS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S3"
::= { rs232aStatusEntry 24 }
rs232aStatusRemoteS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S4"
::= { rs232aStatusEntry 25 }
rs232aStatusRemoteS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S6"
::= { rs232aStatusEntry 26 }
rs232aStatusRemoteS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S8"
::= { rs232aStatusEntry 27 }
rs232aStatusRemoteS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit S9"
::= { rs232aStatusEntry 28 }
rs232aStatusRemoteE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit E4"
::= { rs232aStatusEntry 29 }
rs232aStatusRemoteE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit E5"
::= { rs232aStatusEntry 30 }
rs232aStatusRemoteE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit E6"
::= { rs232aStatusEntry 31 }
rs232aStatusRemoteX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rs232a remote status bit X"
::= { rs232aStatusEntry 32 }
--
-- Alarm Control Table
--
rs232aAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The rs232a alarm control table."
::= { rs232a-card 3 }
rs232aAlarmControlEntry OBJECT-TYPE
SYNTAX Rs232aAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the rs232a alarm control table."
INDEX { rs232aAlarmSlotIndex , rs232aAlarmPortIndex }
::= { rs232aAlarmControlTable 1 }
Rs232aAlarmControlEntry ::= SEQUENCE {
rs232aAlarmSlotIndex LargeSlotIndex,
rs232aAlarmPortIndex SixPortID,
rs232aAlarmSetup AlarmSeverity
}
rs232aAlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aAlarmControlEntry 1 }
rs232aAlarmPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { rs232aAlarmControlEntry 2 }
rs232aAlarmSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { rs232aAlarmControlEntry 3 }
--
-- Alarm History Table
--
rs232aAlmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aAlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: rs232aAlmHistoryUnitIndex "
::= { rs232a-card 4 }
rs232aAlmHistoryEntry OBJECT-TYPE
SYNTAX Rs232aAlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { rs232aAlmHisSlotIndex , rs232aAlmHisPortIndex }
::= { rs232aAlmHistoryTable 1 }
Rs232aAlmHistoryEntry ::= SEQUENCE {
rs232aAlmHisSlotIndex LargeSlotIndex,
rs232aAlmHisPortIndex SixPortID,
rs232aAlmHistoryState INTEGER,
rs232aAlmHistoryCount Counter,
rs232aAlmHistoryEnable AlarmSeverity
}
rs232aAlmHisSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aAlmHistoryEntry 1 }
rs232aAlmHisPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { rs232aAlmHistoryEntry 2 }
rs232aAlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { rs232aAlmHistoryEntry 3 }
rs232aAlmHistoryCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { rs232aAlmHistoryEntry 4 }
rs232aAlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { rs232aAlmHistoryEntry 5 }
--
-- Diagnostic Control Table
--
rs232aDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { rs232a-card 5 }
rs232aDiagControlEntry OBJECT-TYPE
SYNTAX Rs232aDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { rs232aDiagCtrlSlotIndex , rs232aDiagCtrlPortIndex }
::= { rs232aDiagControlTable 1 }
Rs232aDiagControlEntry ::= SEQUENCE {
rs232aDiagCtrlSlotIndex LargeSlotIndex,
rs232aDiagCtrlPortIndex SixPortID,
rs232aNearLoopback INTEGER
}
rs232aDiagCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aDiagControlEntry 1 }
rs232aDiagCtrlPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { rs232aDiagControlEntry 2 }
rs232aNearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
toDTE(2),
toLocal(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rs232a Loopback Type"
::= { rs232aDiagControlEntry 3 }
--
-- Card Control Table
--
rs232aCardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The rs232a Card control table."
::= { rs232a-card 6 }
rs232aCardControlEntry OBJECT-TYPE
SYNTAX Rs232aCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the rs232a Card control table."
INDEX { rs232aCardIndex }
::= { rs232aCardControlTable 1 }
Rs232aCardControlEntry ::= SEQUENCE {
rs232aCardIndex LargeSlotIndex,
rs232aReset INTEGER,
rs232aLoadDefault INTEGER
}
rs232aCardIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aCardControlEntry 1 }
rs232aReset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset rs232a card"
::= { rs232aCardControlEntry 2 }
rs232aLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
na(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { rs232aCardControlEntry 3 }
--
-- Rs232a System Information Table
--
rs232aSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Rs232aSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Rs232a system information table."
::= { rs232a-card 7}
rs232aSystemInfoEntry OBJECT-TYPE
SYNTAX Rs232aSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Rs232a system information table."
INDEX { rs232aSISlotIndex }
::= { rs232aSystemInfoTable 1 }
Rs232aSystemInfoEntry ::= SEQUENCE {
rs232aSISlotIndex LargeSlotIndex,
rs232aPROMVersion DisplayString,
rs232aHardwareVersion DisplayString,
rs232aFpgaVersion DisplayString,
rs232aBank1Version DisplayString,
rs232aBank2Version DisplayString,
rs232aActiveBank INTEGER
}
rs232aSISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { rs232aSystemInfoEntry 1 }
rs232aPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" rs232a PROM Version"
::= { rs232aSystemInfoEntry 2 }
rs232aHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" rs232a Hardware Version"
::= { rs232aSystemInfoEntry 3 }
rs232aFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { rs232aSystemInfoEntry 4 }
rs232aBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { rs232aSystemInfoEntry 5 }
rs232aBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { rs232aSystemInfoEntry 6}
rs232aActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { rs232aSystemInfoEntry 7 }
rs232aTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of Rs232a"
::= { rs232a-card 100 }
--============================================================================--
-- ABRA card MIB
--============================================================================--
--============================================================================--
AbraPortID ::= INTEGER {
group1(1),
group2(2),
group3(3),
group4(4),
group5(5),
group6(6),
group7(7),
group8(8)
}
AbraM2PortID ::= INTEGER {
group1(1),
group2(2),
group3(3),
group4(4),
group5(5),
group6(6),
group7(7),
group8(8),
group9(9),
group10(10),
group11(11),
group12(12),
group13(13),
group14(14),
group15(15),
group16(16),
group17(17),
group18(18),
group19(19),
group20(20),
group21(21),
group22(22),
group23(23),
group24(24),
group25(25),
group26(26),
group27(27),
group28(28),
group29(29),
group30(30),
group31(31),
group32(32),
group33(33),
group34(34),
group35(35),
group36(36),
group37(37),
group38(38),
group39(39),
group40(40),
group41(41),
group42(42)
}
AbraM2ChannelID ::= INTEGER {
ch1master(1),
ch2slave(2),
ch3slave(3)
}
--
-- u/a law Format Table
--
abraModeConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ABRA law format config table."
::= { abra-card 1 }
abraModeConfigEntry OBJECT-TYPE
SYNTAX AbraModeConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Format Mode Table."
INDEX { abraModeConfigSlotIndex }
::= { abraModeConfigTable 1 }
AbraModeConfigEntry ::= SEQUENCE {
abraModeConfigSlotIndex SmallSlotIndex,
abraModeConfigFormat INTEGER
}
abraModeConfigSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraModeConfigEntry 1 }
abraModeConfigFormat OBJECT-TYPE
SYNTAX INTEGER {
uLaw(1),
aLaw(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Format Mode."
::= { abraModeConfigEntry 2 }
--
-- Analogy Bridge Config Table
--
abraConfigureTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraConfigureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Analogy Bridge Switch Config Table."
::= { abra-card 2 }
abraConfigureEntry OBJECT-TYPE
SYNTAX AbraConfigureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of Analogy Bridge Switch Config Table."
INDEX { abraConfigSlotIndex ,
abraConfigGroupIndex ,
abraConfigChIndex }
::= { abraConfigureTable 1 }
AbraConfigureEntry ::= SEQUENCE {
abraConfigSlotIndex SmallSlotIndex,
abraConfigGroupIndex AbraPortID,
abraConfigChIndex GroupChannelID,
abraConfigAnalogBR INTEGER,
abraConfigAttribute INTEGER
}
abraConfigSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraConfigureEntry 1 }
abraConfigGroupIndex OBJECT-TYPE
SYNTAX AbraPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Group index, total 8 port."
::= { abraConfigureEntry 2 }
abraConfigChIndex OBJECT-TYPE
SYNTAX GroupChannelID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel index."
::= { abraConfigureEntry 3 }
abraConfigAnalogBR OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable analog bridge."
::= { abraConfigureEntry 4 }
abraConfigAttribute OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2),
member(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or disable analog bridge."
::= { abraConfigureEntry 5 }
--
-- ABRA Card Control Table
--
abraCardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ABRA Card control table."
::= { abra-card 3 }
abraCardControlEntry OBJECT-TYPE
SYNTAX AbraCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ABRA Card control table."
INDEX { abraCardIndex }
::= { abraCardControlTable 1 }
AbraCardControlEntry ::= SEQUENCE {
abraCardIndex SmallSlotIndex,
abraReset INTEGER,
abraLoadDefault INTEGER
}
abraCardIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraCardControlEntry 1 }
abraReset OBJECT-TYPE
SYNTAX INTEGER {
no(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset abra card"
::= { abraCardControlEntry 2 }
abraLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { abraCardControlEntry 3 }
--
-- ABRA System Information Table
--
abraSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ABRA system information table."
::= { abra-card 4}
abraSystemInfoEntry OBJECT-TYPE
SYNTAX AbraSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ABRA system information table."
INDEX { abraSystemInfoSlotIndex }
::= { abraSystemInfoTable 1 }
AbraSystemInfoEntry ::= SEQUENCE {
abraSystemInfoSlotIndex SmallSlotIndex,
abraSystemInfoPROMVersion DisplayString,
abraSystemInfoHardwareVersion DisplayString,
abraSystemInfoFpgaVersion DisplayString,
abraSystemInfoBank1Version DisplayString,
abraSystemInfoBank2Version DisplayString,
abraSystemInfoActiveBank INTEGER
}
abraSystemInfoSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraSystemInfoEntry 1 }
abraSystemInfoPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" abra PROM Version"
::= { abraSystemInfoEntry 2 }
abraSystemInfoHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" abra Hardware Version"
::= { abraSystemInfoEntry 3 }
abraSystemInfoFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { abraSystemInfoEntry 4 }
abraSystemInfoBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { abraSystemInfoEntry 5 }
abraSystemInfoBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { abraSystemInfoEntry 6}
abraSystemInfoActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank1(1),
bank2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { abraSystemInfoEntry 7 }
--
-- ABRA Silence Detection Table
--
abraSilenceDetTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraSilenceDetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ABRA Silence detection table."
::= { abra-card 5 }
abraSilenceDetEntry OBJECT-TYPE
SYNTAX AbraSilenceDetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ABRA Silence detection table."
INDEX { abraSilenceDetSlotIndex }
::= { abraSilenceDetTable 1 }
AbraSilenceDetEntry ::= SEQUENCE {
abraSilenceDetSlotIndex SmallSlotIndex,
abraSilenceDetSilenceDet INTEGER,
abraSilenceDetThreshold INTEGER,
abraSilenceDetDetPeriod INTEGER
}
abraSilenceDetSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraSilenceDetEntry 1 }
abraSilenceDetSilenceDet OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Silence Detection."
::= { abraSilenceDetEntry 2 }
abraSilenceDetThreshold OBJECT-TYPE
SYNTAX INTEGER (0..8159)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Threshold (uniform PCM code)."
::= { abraSilenceDetEntry 3 }
abraSilenceDetDetPeriod OBJECT-TYPE
SYNTAX INTEGER (0..25)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"No-of-det-period-(N) (each period = 20ms)"
::= { abraSilenceDetEntry 4 }
--
-- ABRA Mode (Master/Slave or Conference) Table
--
abraModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ABRA Mode Config Table."
::= { abra-card 6 }
abraModeEntry OBJECT-TYPE
SYNTAX AbraModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of ABRA Mode Config Table."
INDEX { abraModeSlotIndex ,
abraModeGroupIndex }
::= { abraModeTable 1 }
AbraModeEntry ::= SEQUENCE {
abraModeSlotIndex SmallSlotIndex,
abraModeGroupIndex AbraPortID,
abraMode INTEGER
}
abraModeSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraModeEntry 1 }
abraModeGroupIndex OBJECT-TYPE
SYNTAX AbraPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Group index, total 8 port."
::= { abraModeEntry 2 }
abraMode OBJECT-TYPE
SYNTAX INTEGER {
masterSlave(1),
conference(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of ABRA's Group. (Master/Slave or Conference)"
::= { abraModeEntry 3 }
--
-- ABRA Function (Analog or Digital or MJU) Table
--
abraFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"ABRA Function Config Table."
::= { abra-card 8 }
abraFunctionEntry OBJECT-TYPE
SYNTAX AbraFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of ABRA Function Config Table."
INDEX { abraFunctionSlotIndex ,
abraFunctionGroupIndex }
::= { abraFunctionTable 1 }
AbraFunctionEntry ::= SEQUENCE {
abraFunctionSlotIndex SmallSlotIndex,
abraFunctionGroupIndex AbraPortID,
abraFunction INTEGER,
abraMjuRate INTEGER
}
abraFunctionSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraFunctionEntry 1 }
abraFunctionGroupIndex OBJECT-TYPE
SYNTAX AbraPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Group index, total 8 port."
::= { abraFunctionEntry 2 }
abraFunction OBJECT-TYPE
SYNTAX INTEGER {
analog(1),
digital(2),
mju(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Function of ABRA's Group. (Analog or Digital of MJU)"
::= { abraFunctionEntry 3 }
abraMjuRate OBJECT-TYPE
SYNTAX INTEGER {
subRate(1),
rate64k(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rate of ABRA's MJU Group."
::= { abraFunctionEntry 4 }
--
-- ABRA Card Mode Table
--
abraCardModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraCardModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { abra-card 9 }
abraCardModeEntry OBJECT-TYPE
SYNTAX AbraCardModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { abraCardModeSlotIndex }
::= { abraCardModeTable 1 }
AbraCardModeEntry ::= SEQUENCE {
abraCardModeSlotIndex SmallSlotIndex,
abraCardMode INTEGER
}
abraCardModeSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ABRA slot index"
::= { abraCardModeEntry 1 }
abraCardMode OBJECT-TYPE
SYNTAX INTEGER {
m1(1),
m2(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ABRA Card Mode"
::= { abraCardModeEntry 2 }
--
-- M2 Analogy Bridge Config Table
--
abraM2ConfigureTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraM2ConfigureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Analogy Bridge Switch Config Table."
::= { abra-card 10 }
abraM2ConfigureEntry OBJECT-TYPE
SYNTAX AbraM2ConfigureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of Analogy Bridge Switch Config Table."
INDEX { abraM2ConfigSlotIndex ,
abraM2ConfigGroupIndex ,
abraM2ConfigChIndex }
::= { abraM2ConfigureTable 1 }
AbraM2ConfigureEntry ::= SEQUENCE {
abraM2ConfigSlotIndex SmallSlotIndex,
abraM2ConfigGroupIndex AbraM2PortID,
abraM2ConfigChIndex AbraM2ChannelID,
abraM2ConfigAnalogBR INTEGER,
abraM2ConfigAttribute INTEGER
}
abraM2ConfigSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { abraM2ConfigureEntry 1 }
abraM2ConfigGroupIndex OBJECT-TYPE
SYNTAX AbraM2PortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Echo Group index, total 8 port."
::= { abraM2ConfigureEntry 2 }
abraM2ConfigChIndex OBJECT-TYPE
SYNTAX AbraM2ChannelID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel index."
::= { abraM2ConfigureEntry 3 }
abraM2ConfigAnalogBR OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable analog bridge."
::= { abraM2ConfigureEntry 4 }
abraM2ConfigAttribute OBJECT-TYPE
SYNTAX INTEGER {
master(1),
slave(2)
--member(3),
--na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enable or disable analog bridge."
::= { abraM2ConfigureEntry 5 }
--
-- ABRA M2 Input Signal Table
--
abraM2InputTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraM2InputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { abra-card 11 }
abraM2InputEntry OBJECT-TYPE
SYNTAX AbraM2InputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { abraM2InputSlotIndex }
::= { abraM2InputTable 1 }
AbraM2InputEntry ::= SEQUENCE {
abraM2InputSlotIndex SmallSlotIndex,
abraM2Input INTEGER
}
abraM2InputSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ABRA slot index"
::= { abraM2InputEntry 1 }
abraM2Input OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
neg3dbi(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ABRA Card Mode"
::= { abraM2InputEntry 2 }
--
-- ABRA card protection Table
--
abraCardProtectTable OBJECT-TYPE
SYNTAX SEQUENCE OF AbraCardProtectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { abra-card 12 }
abraCardProtectEntry OBJECT-TYPE
SYNTAX AbraCardProtectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { abraCpSlotIndex }
::= { abraCardProtectTable 1 }
AbraCardProtectEntry ::= SEQUENCE {
abraCpSlotIndex SmallSlotIndex,
abraCardProtection INTEGER,
abraCardProtectAlarm AlarmSeverity,
abraForceSwitch INTEGER,
abraCardProtectStatus INTEGER
}
abraCpSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ABRA slot index"
::= { abraCardProtectEntry 1 }
abraCardProtection OBJECT-TYPE
SYNTAX INTEGER {
notAvailable(0),
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ABRA Card Protection setup"
::= { abraCardProtectEntry 2 }
abraCardProtectAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ABRA Card Protection alarm"
::= { abraCardProtectEntry 3 }
abraForceSwitch OBJECT-TYPE
SYNTAX INTEGER {
na(1),
forceSwitch(2),
forcePrimary(3),
forceSecondary(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ABRA Card Protection force switch"
::= { abraCardProtectEntry 4 }
abraCardProtectStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
standby(2),
working(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ABRA Card Protection status"
::= { abraCardProtectEntry 5 }
--
abraTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of ABRA"
::= { abra-card 100 }
--======================================================================--
--======================================================================--
-- TTA-card MIB
--======================================================================--
--======================================================================--
ttaSysConfigTable OBJECT IDENTIFIER ::= { tta-card 1 }
--
-- In & Out Table
--
ttaInOutTable OBJECT IDENTIFIER ::= { ttaSysConfigTable 1 }
--
-- In & Out 1 Table
--
ttaInOut1Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaInOut1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA In and Out 1 Table "
::= { ttaInOutTable 1 }
ttaInOut1Entry OBJECT-TYPE
SYNTAX TtaInOut1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA In and Out 1 Table "
INDEX { ttaInOut1SlotIndex , ttaInOut1PortIndex }
::= { ttaInOut1Table 1 }
TtaInOut1Entry ::= SEQUENCE {
ttaInOut1SlotIndex LargeSlotIndex,
ttaInOut1PortIndex FourPortID,
ttaInOut1PreTripTimer INTEGER,
ttaInOut1TripHoldTimer INTEGER,
ttaInOut1DebounceTimer INTEGER
}
ttaInOut1SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaInOut1Entry 1 }
ttaInOut1PortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaInOut1Entry 2 }
ttaInOut1PreTripTimer OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PRE-TRIP Timer (ms)(1-30) "
::= { ttaInOut1Entry 3 }
ttaInOut1TripHoldTimer OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" TRIP-HOLD Timer (ms)(1-256) "
::= { ttaInOut1Entry 4 }
ttaInOut1DebounceTimer OBJECT-TYPE
SYNTAX INTEGER (1..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Debounce Timer (ms)(1-3) "
::= { ttaInOut1Entry 5 }
--
-- In & Out 2 Table
--
ttaInOut2Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaInOut2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA In and Out 2 Table1 "
::= { ttaInOutTable 2 }
ttaInOut2Entry OBJECT-TYPE
SYNTAX TtaInOut2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA In and Out 2 Table "
INDEX { ttaInOut2SlotIndex }
::= { ttaInOut2Table 1 }
TtaInOut2Entry ::= SEQUENCE {
ttaInOut2SlotIndex LargeSlotIndex,
-- ttaInOut2InOutInv INTEGER,
ttaInOut2IrigTimeStp INTEGER,
ttaInOut2PickUpNum INTEGER,
ttaInOut2DataDropTmr INTEGER
-- ttaInOut2GlobalLoopbk INTEGER
}
ttaInOut2SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaInOut2Entry 1 }
-- ttaInOut2InOutInv OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(1),
-- enable(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Input & Output Inverter "
-- ::= { ttaInOut2Entry 2 }
ttaInOut2IrigTimeStp OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IRIG Time Setup "
::= { ttaInOut2Entry 3 }
ttaInOut2PickUpNum OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Pick Up Number (times)(1-255) "
::= { ttaInOut2Entry 4 }
ttaInOut2DataDropTmr OBJECT-TYPE
SYNTAX INTEGER (5..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Data Drop Timer (ms)(5-1000) "
::= { ttaInOut2Entry 5 }
-- ttaInOut2GlobalLoopbk OBJECT-TYPE
-- SYNTAX INTEGER {
-- disable(1),
-- enable(2)
-- }
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Global Loopback "
-- ::= { ttaInOut2Entry 6 }
ttaNewInOut1Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaNewInOut1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA NewIn and Out 1 Table "
::= { ttaInOutTable 3 }
ttaNewInOut1Entry OBJECT-TYPE
SYNTAX TtaNewInOut1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA In and Out 1 Table "
INDEX { ttaNewInOut1Slot , ttaNewInOut1Port }
::= { ttaNewInOut1Table 1 }
TtaNewInOut1Entry ::= SEQUENCE {
ttaNewInOut1Slot LargeSlotIndex,
ttaNewInOut1Port FourPortID,
ttaNewInOut1InSup INTEGER,
ttaNewInOut1InSigLimit INTEGER,
ttaNewInOut1InSigExtend INTEGER,
ttaNewInOut1OutPerTrip INTEGER,
ttaNewInOut1OutSigLimit INTEGER,
ttaNewInOut1OutSigExtend INTEGER
}
ttaNewInOut1Slot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaNewInOut1Entry 1 }
ttaNewInOut1Port OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaNewInOut1Entry 2 }
ttaNewInOut1InSup OBJECT-TYPE
SYNTAX INTEGER (0..255) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input Suppression (ms)(0-255) "
::= { ttaNewInOut1Entry 3 }
ttaNewInOut1InSigLimit OBJECT-TYPE
SYNTAX INTEGER (0..4095) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input Signal Limit (ms)(0-4095) "
::= { ttaNewInOut1Entry 4 }
ttaNewInOut1InSigExtend OBJECT-TYPE
SYNTAX INTEGER (0..255) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input Signal Extend (ms)(0-255) "
::= { ttaNewInOut1Entry 5 }
ttaNewInOut1OutPerTrip OBJECT-TYPE
SYNTAX INTEGER (1..30) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Pre Trip Timer (ms)(1-30) "
::= { ttaNewInOut1Entry 6 }
ttaNewInOut1OutSigLimit OBJECT-TYPE
SYNTAX INTEGER (0..4095) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Output Signal Limit (ms)(0-4095) "
::= { ttaNewInOut1Entry 7 }
ttaNewInOut1OutSigExtend OBJECT-TYPE
SYNTAX INTEGER (0..255) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Output Signal Extend (ms)(0-255) "
::= { ttaNewInOut1Entry 8 }
--
-- NEW In & Out 2 Table
--
ttaNewInOut2Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaNewInOut2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA New In and Out 2 Table1 "
::= { ttaInOutTable 4 }
ttaNewInOut2Entry OBJECT-TYPE
SYNTAX TtaNewInOut2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA NewIn and Out 2 Table "
INDEX { ttaNewInOut2Slot}
::= { ttaNewInOut2Table 1 }
TtaNewInOut2Entry ::= SEQUENCE {
ttaNewInOut2Slot LargeSlotIndex,
ttaNewInOut2InOutMode INTEGER,
ttaNewInOut2IrigTimeStp INTEGER,
ttaNewInOut2PickUpNum INTEGER,
ttaNewInOut2DataDropTmr INTEGER
}
ttaNewInOut2Slot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaNewInOut2Entry 1 }
ttaNewInOut2InOutMode OBJECT-TYPE
SYNTAX INTEGER {
one-to-one(1),
four-to-one(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input & Output Inverter "
::= { ttaNewInOut2Entry 2 }
ttaNewInOut2IrigTimeStp OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IRIG Time Setup "
::= { ttaNewInOut2Entry 3 }
ttaNewInOut2PickUpNum OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Pick Up Number (times)(1-255) "
::= { ttaNewInOut2Entry 4 }
ttaNewInOut2DataDropTmr OBJECT-TYPE
SYNTAX INTEGER (5..1000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Data Drop Timer (ms)(5-1000) "
::= { ttaNewInOut2Entry 5 }
--
-- Alarm Delay Min/Max Times Table
--
ttaAlarmDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaAlarmDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Alarm Delay Min/Max Times Table "
::= { ttaSysConfigTable 2 }
ttaAlarmDelayEntry OBJECT-TYPE
SYNTAX TtaAlarmDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Alarm Delay Min/Max Times Table "
INDEX { ttaAlarmDelaySlotIndex , ttaAlarmDelayPortIndex }
::= { ttaAlarmDelayTable 1 }
TtaAlarmDelayEntry ::= SEQUENCE {
ttaAlarmDelaySlotIndex LargeSlotIndex,
ttaAlarmDelayPortIndex FourPortID,
ttaAlarmDelayUpper INTEGER,
ttaAlarmDelayLower INTEGER,
ttaAlarmDelayLocUserId INTEGER,
ttaAlarmDelayReUserId INTEGER
-- ttaAlarmInputDelay1 INTEGER,
-- ttaAlarmInputDelay2 INTEGER
}
ttaAlarmDelaySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaAlarmDelayEntry 1 }
ttaAlarmDelayPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaAlarmDelayEntry 2 }
ttaAlarmDelayUpper OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Upper (us)(0-1000000) "
::= { ttaAlarmDelayEntry 3 }
ttaAlarmDelayLower OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Lower (us)(0-1000000) "
::= { ttaAlarmDelayEntry 4 }
ttaAlarmDelayLocUserId OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Local User ID (0-127) "
::= { ttaAlarmDelayEntry 5 }
ttaAlarmDelayReUserId OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Remote User ID (0-127) "
::= { ttaAlarmDelayEntry 6 }
-- ttaAlarmInputDelay1 OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Input Delay 1 (0-255) "
-- ::= { ttaAlarmDelayEntry 7 }
-- ttaAlarmInputDelay2 OBJECT-TYPE
-- SYNTAX INTEGER (0..255)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Input Delay 2 (0-255) "
-- ::= { ttaAlarmDelayEntry 8 }
--
--Transfer Trip Input Rating Table
--
ttaTrTripInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaTrTripInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Transfer Trip Input Rating Table "
::= { ttaSysConfigTable 3 }
ttaTrTripInputEntry OBJECT-TYPE
SYNTAX TtaTrTripInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Transfer Trip Input Rating Table "
INDEX { ttaTrTripInputSlotIndex , ttaTrTripInputPortIndex }
::= { ttaTrTripInputTable 1 }
TtaTrTripInputEntry ::= SEQUENCE {
ttaTrTripInputSlotIndex LargeSlotIndex,
ttaTrTripInputPortIndex FourPortID,
ttaTrTripInputMaxDCInput INTEGER
}
ttaTrTripInputSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaTrTripInputEntry 1 }
ttaTrTripInputPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaTrTripInputEntry 2 }
ttaTrTripInputMaxDCInput OBJECT-TYPE
SYNTAX INTEGER {
power24V(1),
power48V(2),
power125V(3),
power250V(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Max. DC Input (V) "
::= { ttaTrTripInputEntry 3 }
--
-- Multi-channel Table
--
ttaMultiChTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaMultiChEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Multi-channel Table "
::= { ttaSysConfigTable 4 }
ttaMultiChEntry OBJECT-TYPE
SYNTAX TtaMultiChEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Multi-channel Table "
INDEX { ttaMultiChSlotIndex , ttaMultiChPortIndex }
::= { ttaMultiChTable 1 }
TtaMultiChEntry ::= SEQUENCE {
ttaMultiChSlotIndex LargeSlotIndex,
ttaMultiChPortIndex FourPortID,
ttaMultiChNoOfTS INTEGER
}
ttaMultiChSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaMultiChEntry 1 }
ttaMultiChPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaMultiChEntry 2 }
ttaMultiChNoOfTS OBJECT-TYPE
SYNTAX INTEGER (1..3)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" # of TS (1-3)"
::= { ttaMultiChEntry 3 }
--
-- Channel Lost Detection Table
--
ttaChLostDetTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaChLostDetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Channel Lost Detection Table "
::= { ttaSysConfigTable 5 }
ttaChLostDetEntry OBJECT-TYPE
SYNTAX TtaChLostDetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Channel Lost Detection Table "
INDEX { ttaChLostDetSlotIndex , ttaChLostDetPortIndex }
::= { ttaChLostDetTable 1 }
TtaChLostDetEntry ::= SEQUENCE {
ttaChLostDetSlotIndex LargeSlotIndex,
ttaChLostDetPortIndex FourPortID,
ttaChLostDetLostDet INTEGER
}
ttaChLostDetSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaChLostDetEntry 1 }
ttaChLostDetPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaChLostDetEntry 2 }
ttaChLostDetLostDet OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Lost Detection "
::= { ttaChLostDetEntry 3 }
--
-- CH. Lost Relay One Shot Timer Table
--
ttaOneShotTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaOneShotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA CH. Lost Relay One Shot Timer Table "
::= { ttaSysConfigTable 6 }
ttaOneShotEntry OBJECT-TYPE
SYNTAX TtaOneShotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA CH. Lost Relay One Shot Timer Table "
INDEX { ttaOneShotSlotIndex , ttaOneShotPortIndex }
::= { ttaOneShotTable 1 }
TtaOneShotEntry ::= SEQUENCE {
ttaOneShotSlotIndex LargeSlotIndex,
ttaOneShotPortIndex FourPortID,
ttaOneShotOneShotPer INTEGER
}
ttaOneShotSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaOneShotEntry 1 }
ttaOneShotPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaOneShotEntry 2 }
ttaOneShotOneShotPer OBJECT-TYPE
SYNTAX INTEGER (0..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" One Shot Period (ms)(0-1023) "
::= { ttaOneShotEntry 3 }
--
-- Alarm Relay Control Table
--
ttaAlmRlyCtrlTable OBJECT IDENTIFIER ::= { ttaSysConfigTable 7 }
--
-- Alarm Relay Control 1 Table
--
ttaAlmRlyCtrl1Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaAlmRlyCtrl1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Alarm Relay Control 1 Table "
::= { ttaAlmRlyCtrlTable 1 }
ttaAlmRlyCtrl1Entry OBJECT-TYPE
SYNTAX TtaAlmRlyCtrl1Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Alarm Relay Control 1 Table "
INDEX { ttaAlmRlyCtrl1SlotIndex , ttaAlmRlyCtrl1PortIndex }
::= { ttaAlmRlyCtrl1Table 1 }
TtaAlmRlyCtrl1Entry ::= SEQUENCE {
ttaAlmRlyCtrl1SlotIndex LargeSlotIndex,
ttaAlmRlyCtrl1PortIndex INTEGER,
ttaAlmRlyCtrl1Status AlarmSeverity,
ttaAlmRlyCtrl1Clean INTEGER
}
ttaAlmRlyCtrl1SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaAlmRlyCtrl1Entry 1 }
ttaAlmRlyCtrl1PortIndex OBJECT-TYPE
SYNTAX INTEGER {
p1Of1(1),
p1Of2(2),
p2Of1(3),
p2Of2(4),
p3Of1(5),
p3Of2(6),
p4Of1(7),
p4Of2(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port p1Of1 to p4Of2, Total 8 ports "
::= { ttaAlmRlyCtrl1Entry 2 }
ttaAlmRlyCtrl1Status OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Status "
::= { ttaAlmRlyCtrl1Entry 3 }
ttaAlmRlyCtrl1Clean OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Clean "
::= { ttaAlmRlyCtrl1Entry 4 }
--
-- Alarm Relay Control 2 Table
--
ttaAlmRlyCtrl2Table OBJECT-TYPE
SYNTAX SEQUENCE OF TtaAlmRlyCtrl2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Alarm Relay Control 2 Table "
::= { ttaAlmRlyCtrlTable 2 }
ttaAlmRlyCtrl2Entry OBJECT-TYPE
SYNTAX TtaAlmRlyCtrl2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Alarm Relay Control 2 Table "
INDEX { ttaRlySlotIndex }
::= { ttaAlmRlyCtrl2Table 1 }
TtaAlmRlyCtrl2Entry ::= SEQUENCE {
ttaRlySlotIndex LargeSlotIndex,
ttaRlyCardAlmRlyStatus AlarmSeverity,
ttaRlyCardAlmRlyClean INTEGER
}
ttaRlySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaAlmRlyCtrl2Entry 1 }
ttaRlyCardAlmRlyStatus OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Card Alarm Relay Status "
::= { ttaAlmRlyCtrl2Entry 2 }
ttaRlyCardAlmRlyClean OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Card Alarm Relay Clean "
::= { ttaAlmRlyCtrl2Entry 3 }
--
-- PCM Rx Threshold Table
--
ttaRxThrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaRxThrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The PCM Rx Threshold Table "
::= { ttaSysConfigTable 8 }
ttaRxThrEntry OBJECT-TYPE
SYNTAX TtaRxThrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA PCM Rx Threshold Table "
INDEX { ttaRxThrSlotIndex , ttaRxThrChIndex }
::= { ttaRxThrTable 1 }
TtaRxThrEntry ::= SEQUENCE {
ttaRxThrSlotIndex LargeSlotIndex,
ttaRxThrChIndex INTEGER,
ttaRxThrRxThreshold INTEGER
}
ttaRxThrSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaRxThrEntry 1 }
ttaRxThrChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaRxThrEntry 2 }
ttaRxThrRxThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PCM Rx Threshold (frame)(1-255), 0 can not use "
::= { ttaRxThrEntry 3 }
--
-- Trip Output OR Table
--
ttaORTripOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaORTripOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Trip Output OR Table "
::= { ttaSysConfigTable 9 }
ttaORTripOutputEntry OBJECT-TYPE
SYNTAX TtaORTripOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Transfer Trip Input Rating Table "
INDEX { ttaORTripOutputSlot , ttaORTripOutputPort }
::= { ttaORTripOutputTable 1 }
TtaORTripOutputEntry ::= SEQUENCE {
ttaORTripOutputSlot LargeSlotIndex,
ttaORTripOutputPort FourPortID,
ttaORTripOutputIn1 INTEGER,
ttaORTripOutputIn2 INTEGER,
ttaORTripOutputIn3 INTEGER,
ttaORTripOutputIn4 INTEGER,
ttaORTripOutputIn1Delay1 INTEGER,
ttaORTripOutputIn2Delay1 INTEGER,
ttaORTripOutputIn3Delay1 INTEGER,
ttaORTripOutputIn4Delay1 INTEGER,
ttaORTripOutputIn1Delay2 INTEGER,
ttaORTripOutputIn2Delay2 INTEGER,
ttaORTripOutputIn3Delay2 INTEGER,
ttaORTripOutputIn4Delay2 INTEGER,
ttaORTripOutputRx1 INTEGER,
ttaORTripOutputRx2 INTEGER,
ttaORTripOutputRx3 INTEGER,
ttaORTripOutputRx4 INTEGER,
ttaORTripOutputRx1Inv INTEGER,
ttaORTripOutputRx2Inv INTEGER,
ttaORTripOutputRx3Inv INTEGER,
ttaORTripOutputRx4Inv INTEGER
}
ttaORTripOutputSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaORTripOutputEntry 1 }
ttaORTripOutputPort OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaORTripOutputEntry 2 }
ttaORTripOutputIn1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 1 "
::= { ttaORTripOutputEntry 3 }
ttaORTripOutputIn2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 "
::= { ttaORTripOutputEntry 4 }
ttaORTripOutputIn3 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3"
::= { ttaORTripOutputEntry 5 }
ttaORTripOutputIn4 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4"
::= { ttaORTripOutputEntry 6 }
ttaORTripOutputIn1Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In Delay1"
::= { ttaORTripOutputEntry 7 }
ttaORTripOutputIn2Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 Delay1"
::= { ttaORTripOutputEntry 8 }
ttaORTripOutputIn3Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3 Delay1"
::= { ttaORTripOutputEntry 9 }
ttaORTripOutputIn4Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4 Delay1"
::= { ttaORTripOutputEntry 10}
ttaORTripOutputIn1Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In Delay2"
::= { ttaORTripOutputEntry 11 }
ttaORTripOutputIn2Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 Delay2"
::= { ttaORTripOutputEntry 12 }
ttaORTripOutputIn3Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3 Delay2"
::= { ttaORTripOutputEntry 13 }
ttaORTripOutputIn4Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4 Delay2"
::= { ttaORTripOutputEntry 14}
ttaORTripOutputRx1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 1 "
::= { ttaORTripOutputEntry 15}
ttaORTripOutputRx2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 2 "
::= { ttaORTripOutputEntry 16}
ttaORTripOutputRx3 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 3 "
::= { ttaORTripOutputEntry 17}
ttaORTripOutputRx4 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 4 "
::= { ttaORTripOutputEntry 18}
ttaORTripOutputRx1Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 1 inverse"
::= { ttaORTripOutputEntry 19}
ttaORTripOutputRx2Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 2 inverse"
::= { ttaORTripOutputEntry 20}
ttaORTripOutputRx3Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 3 inverse"
::= { ttaORTripOutputEntry 21}
ttaORTripOutputRx4Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 4 inverse"
::= { ttaORTripOutputEntry 22}
--
-- Trip Output AND Table
--
ttaANDTripOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaANDTripOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Trip Output AND Table "
::= { ttaSysConfigTable 10 }
ttaANDTripOutputEntry OBJECT-TYPE
SYNTAX TtaANDTripOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Transfer Trip Input Rating Table "
INDEX { ttaANDTripOutputSlot , ttaANDTripOutputPort }
::= { ttaANDTripOutputTable 1 }
TtaANDTripOutputEntry ::= SEQUENCE {
ttaANDTripOutputSlot LargeSlotIndex,
ttaANDTripOutputPort FourPortID,
ttaANDTripOutputIn1 INTEGER,
ttaANDTripOutputIn2 INTEGER,
ttaANDTripOutputIn3 INTEGER,
ttaANDTripOutputIn4 INTEGER,
ttaANDTripOutputIn1Delay1 INTEGER,
ttaANDTripOutputIn2Delay1 INTEGER,
ttaANDTripOutputIn3Delay1 INTEGER,
ttaANDTripOutputIn4Delay1 INTEGER,
ttaANDTripOutputIn1Delay2 INTEGER,
ttaANDTripOutputIn2Delay2 INTEGER,
ttaANDTripOutputIn3Delay2 INTEGER,
ttaANDTripOutputIn4Delay2 INTEGER,
ttaANDTripOutputRx1 INTEGER,
ttaANDTripOutputRx2 INTEGER,
ttaANDTripOutputRx3 INTEGER,
ttaANDTripOutputRx4 INTEGER,
ttaANDTripOutputRx1Inv INTEGER,
ttaANDTripOutputRx2Inv INTEGER,
ttaANDTripOutputRx3Inv INTEGER,
ttaANDTripOutputRx4Inv INTEGER
}
ttaANDTripOutputSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaANDTripOutputEntry 1 }
ttaANDTripOutputPort OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaANDTripOutputEntry 2 }
ttaANDTripOutputIn1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 1 "
::= { ttaANDTripOutputEntry 3 }
ttaANDTripOutputIn2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 "
::= { ttaANDTripOutputEntry 4 }
ttaANDTripOutputIn3 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3"
::= { ttaANDTripOutputEntry 5 }
ttaANDTripOutputIn4 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4"
::= { ttaANDTripOutputEntry 6 }
ttaANDTripOutputIn1Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In Delay1"
::= { ttaANDTripOutputEntry 7 }
ttaANDTripOutputIn2Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 Delay1"
::= { ttaANDTripOutputEntry 8 }
ttaANDTripOutputIn3Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3 Delay1"
::= { ttaANDTripOutputEntry 9 }
ttaANDTripOutputIn4Delay1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4 Delay1"
::= { ttaANDTripOutputEntry 10}
ttaANDTripOutputIn1Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In Delay2"
::= { ttaANDTripOutputEntry 11 }
ttaANDTripOutputIn2Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 2 Delay2"
::= { ttaANDTripOutputEntry 12 }
ttaANDTripOutputIn3Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 3 Delay2"
::= { ttaANDTripOutputEntry 13 }
ttaANDTripOutputIn4Delay2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" In 4 Delay2"
::= { ttaANDTripOutputEntry 14}
ttaANDTripOutputRx1 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 1 "
::= { ttaANDTripOutputEntry 15}
ttaANDTripOutputRx2 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 2 "
::= { ttaANDTripOutputEntry 16}
ttaANDTripOutputRx3 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 3 "
::= { ttaANDTripOutputEntry 17}
ttaANDTripOutputRx4 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 4 "
::= { ttaANDTripOutputEntry 18}
ttaANDTripOutputRx1Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 1 inverse"
::= { ttaANDTripOutputEntry 19}
ttaANDTripOutputRx2Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 2 inverse"
::= { ttaANDTripOutputEntry 20}
ttaANDTripOutputRx3Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 3 inverse"
::= { ttaANDTripOutputEntry 21}
ttaANDTripOutputRx4Inv OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Rx 4 inverse"
::= { ttaANDTripOutputEntry 22}
--
-- Input Delay Min/Max Times Table
--
ttaInputDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaInputDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Input Delay Min/Max Times Table "
::= { ttaSysConfigTable 11 }
ttaInputDelayEntry OBJECT-TYPE
SYNTAX TtaInputDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Input Delay Min/Max Times Table "
INDEX { ttaInputDelaySlot , ttaInputDelayPort }
::= { ttaInputDelayTable 1 }
TtaInputDelayEntry ::= SEQUENCE {
ttaInputDelaySlot LargeSlotIndex,
ttaInputDelayPort FourPortID,
ttaInputDelay1 INTEGER,
ttaInputDelay2 INTEGER
}
ttaInputDelaySlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaInputDelayEntry 1 }
ttaInputDelayPort OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaInputDelayEntry 2 }
ttaInputDelay1 OBJECT-TYPE
SYNTAX INTEGER (0..65535) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input Delay 1 (0-255) "
::= { ttaInputDelayEntry 3 }
ttaInputDelay2 OBJECT-TYPE
SYNTAX INTEGER (0..65535) --//RIKER2021 SilverCreek
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Input Delay 2 (0-255) "
::= { ttaInputDelayEntry 4 }
ttaAlarmTable OBJECT IDENTIFIER ::= { tta-card 2 }
--
--Alarm Trap Debounce Time Table
--
-- ttaAlmTrapDbTimeTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TtaAlmTrapDbTimeEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- " The TTA Alarm Trap Debounce Time Table "
-- ::= { ttaAlarmTable 1 }
-- ttaAlmTrapDbTimeEntry OBJECT-TYPE
-- SYNTAX TtaAlmTrapDbTimeEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- " An entry in the Alarm Trap Debounce Time Table "
-- INDEX {ttaAlmTrapDbTimeSlotIndex }
-- ::= { ttaAlmTrapDbTimeTable 1 }
-- TtaAlmTrapDbTimeEntry ::= SEQUENCE {
-- ttaAlmTrapDbTimeSlotIndex LargeSlotIndex,
-- ttaAlmTrapDbTimeAlmTrapDbTime INTEGER
-- }
-- ttaAlmTrapDbTimeSlotIndex OBJECT-TYPE
-- SYNTAX LargeSlotIndex
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot 1~12, total 12 slots."
-- ::= { ttaAlmTrapDbTimeEntry 1 }
-- ttaAlmTrapDbTimeAlmTrapDbTime OBJECT-TYPE
-- SYNTAX INTEGER (0..2500)
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- " Alarm Trap Debounce Time "
-- ::= { ttaAlmTrapDbTimeEntry 2 }
--
-- Alarm Setup Table
--
ttaAlarmSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaAlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Alarm Setup Table "
::= { ttaAlarmTable 1 }
ttaAlarmSetupEntry OBJECT-TYPE
SYNTAX TtaAlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Alarm Setup Table "
INDEX { ttaAlarmSlotIndex }
::= { ttaAlarmSetupTable 1 }
TtaAlarmSetupEntry ::= SEQUENCE {
ttaAlarmSlotIndex LargeSlotIndex,
ttaAlarmInputTrigger AlarmSeverity,
ttaAlarmOutputTrigger AlarmSeverity,
ttaAlarmRTTimeRange AlarmSeverity,
ttaAlarmLocalChLost AlarmSeverity,
ttaAlarmRemoteChLost AlarmSeverity,
ttaAlarmIrigLoss AlarmSeverity,
ttaAlarmTestTrigger AlarmSeverity,
ttaAlarmTestResponse AlarmSeverity
}
ttaAlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaAlarmSetupEntry 1 }
ttaAlarmInputTrigger OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 2 }
ttaAlarmOutputTrigger OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 3 }
ttaAlarmRTTimeRange OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 4 }
ttaAlarmLocalChLost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 5 }
ttaAlarmRemoteChLost OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 6 }
ttaAlarmIrigLoss OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 7 }
ttaAlarmTestTrigger OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 8 }
ttaAlarmTestResponse OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm is enabled or not "
::= { ttaAlarmSetupEntry 9 }
--
-- Alarm Queue Table
--
ttaAlmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Alarm Queue Table "
::= { ttaAlarmTable 2 }
ttaAlmQueueEntry OBJECT-TYPE
SYNTAX TtaAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Alarm Queue Table "
INDEX { ttaAlmQueueIndex }
::= { ttaAlmQueueTable 1 }
TtaAlmQueueEntry ::= SEQUENCE {
ttaAlmQueueIndex INTEGER (1..40),
ttaAlmQueueString DisplayString (SIZE(0..255)),
ttaAlmQueueType AlarmType,
ttaAlmQueueSlot AlarmSlotIndex,
ttaAlmQueuePort AlarmPort,
ttaAlmQueueSeverity AlarmSeverityDisp
}
ttaAlmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index (1-40)"
::= { ttaAlmQueueEntry 1 }
ttaAlmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Queue String "
::= { ttaAlmQueueEntry 2 }
ttaAlmQueueType OBJECT-TYPE
SYNTAX AlarmType
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm type "
::= { ttaAlmQueueEntry 3 }
ttaAlmQueueSlot OBJECT-TYPE
SYNTAX AlarmSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Slot"
::= { ttaAlmQueueEntry 4 }
ttaAlmQueuePort OBJECT-TYPE
SYNTAX AlarmPort
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Port"
::= { ttaAlmQueueEntry 5 }
ttaAlmQueueSeverity OBJECT-TYPE
SYNTAX AlarmSeverityDisp
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Severity "
::= { ttaAlmQueueEntry 6 }
ttaSysStatusTable OBJECT IDENTIFIER ::= { tta-card 3 }
--
--Delay Time Table
--
ttaDelayTimeTable OBJECT IDENTIFIER ::= { ttaSysStatusTable 1 }
--
--One Way Delay Measurement
--
ttaOneWayDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaOneWayDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The One Way Delay Measurement Table "
::= { ttaDelayTimeTable 1 }
ttaOneWayDelayEntry OBJECT-TYPE
SYNTAX TtaOneWayDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the One Way Delay Measurement Table "
INDEX { ttaOneWayDelaySlotIndex , ttaOneWayDelayChIndex }
::= { ttaOneWayDelayTable 1 }
TtaOneWayDelayEntry ::= SEQUENCE {
ttaOneWayDelaySlotIndex LargeSlotIndex,
ttaOneWayDelayChIndex INTEGER,
ttaOneWayDelayMax DisplayString (SIZE(0..255)),
ttaOneWayDelayMin DisplayString (SIZE(0..255)),
ttaOneWayDelayInbound DisplayString (SIZE(0..255)),
ttaOneWayDelayOutbound DisplayString (SIZE(0..255))
}
ttaOneWayDelaySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaOneWayDelayEntry 1 }
ttaOneWayDelayChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaOneWayDelayEntry 2 }
ttaOneWayDelayMax OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Max (ms) "
::= { ttaOneWayDelayEntry 3 }
ttaOneWayDelayMin OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Min (ms) "
::= { ttaOneWayDelayEntry 4 }
ttaOneWayDelayInbound OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Inbound (ms) "
::= { ttaOneWayDelayEntry 5 }
ttaOneWayDelayOutbound OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Outbound (ms) "
::= { ttaOneWayDelayEntry 6 }
--
--R-Trip Delay Measurement
--
ttaRTripDelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaRTripDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The R-Trip Delay Measurement Table "
::= { ttaDelayTimeTable 2 }
ttaRTripDelayEntry OBJECT-TYPE
SYNTAX TtaRTripDelayEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the R-Trip Delay Measurement Table "
INDEX { ttaRTripDelaySlotIndex , ttaRTripDelayChIndex }
::= { ttaRTripDelayTable 1 }
TtaRTripDelayEntry ::= SEQUENCE {
ttaRTripDelaySlotIndex LargeSlotIndex,
ttaRTripDelayChIndex INTEGER,
ttaRTripDelayMax DisplayString (SIZE(0..255)),
ttaRTripDelayMin DisplayString (SIZE(0..255)),
ttaRTripDelayInbound DisplayString (SIZE(0..255)),
ttaRTripDelayOutbound DisplayString (SIZE(0..255))
}
ttaRTripDelaySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaRTripDelayEntry 1 }
ttaRTripDelayChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaRTripDelayEntry 2 }
ttaRTripDelayMax OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Max (ms) "
::= { ttaRTripDelayEntry 3 }
ttaRTripDelayMin OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Min (ms) "
::= { ttaRTripDelayEntry 4 }
ttaRTripDelayInbound OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Inbound (ms) "
::= { ttaRTripDelayEntry 5 }
ttaRTripDelayOutbound OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Outbound (ms) "
::= { ttaRTripDelayEntry 6 }
--
--Transfer Trip Status Table
--
ttaTrTripStaTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaTrTripStaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Transfer Trip Status Table "
::= { ttaSysStatusTable 2 }
ttaTrTripStaEntry OBJECT-TYPE
SYNTAX TtaTrTripStaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Transfer Trip Status Table "
INDEX { ttaTrTripStaSlotIndex , ttaTrTripStaPortIndex }
::= { ttaTrTripStaTable 1 }
TtaTrTripStaEntry ::= SEQUENCE {
ttaTrTripStaSlotIndex LargeSlotIndex,
ttaTrTripStaPortIndex FourPortID,
ttaTrTripStaInput INTEGER,
ttaTrTripStaOutput INTEGER
}
ttaTrTripStaSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaTrTripStaEntry 1 }
ttaTrTripStaPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 4, Total 4 ports "
::= { ttaTrTripStaEntry 2 }
ttaTrTripStaInput OBJECT-TYPE
SYNTAX INTEGER{
offOpen(1),
onClose(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Input "
::= { ttaTrTripStaEntry 3 }
ttaTrTripStaOutput OBJECT-TYPE
SYNTAX INTEGER{
offOpen(1),
onClose(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Output "
::= { ttaTrTripStaEntry 4 }
--
--Remote Alarm Indication Table
--
ttaReAlarmIndTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaReAlarmIndEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Remote Alarm Indication Table "
::= { ttaSysStatusTable 3 }
ttaReAlarmIndEntry OBJECT-TYPE
SYNTAX TtaReAlarmIndEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Remote Alarm Indication Table "
INDEX { ttaReAlarmIndSlotIndex , ttaReAlarmIndChIndex }
::= { ttaReAlarmIndTable 1 }
TtaReAlarmIndEntry ::= SEQUENCE {
ttaReAlarmIndSlotIndex LargeSlotIndex,
ttaReAlarmIndChIndex INTEGER,
ttaReAlarmIndStatus INTEGER
}
ttaReAlarmIndSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaReAlarmIndEntry 1 }
ttaReAlarmIndChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaReAlarmIndEntry 2 }
ttaReAlarmIndStatus OBJECT-TYPE
SYNTAX INTEGER{
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Status "
::= { ttaReAlarmIndEntry 3 }
--
-- IRIG Status Table
--
ttaIrigStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaIrigStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA IRIG Status Table "
::= { ttaSysStatusTable 4 }
ttaIrigStatusEntry OBJECT-TYPE
SYNTAX TtaIrigStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA IRIG Status Table "
INDEX { ttaIrigSlotIndex }
::= { ttaIrigStatusTable 1 }
TtaIrigStatusEntry ::= SEQUENCE {
ttaIrigSlotIndex LargeSlotIndex,
ttaIrigSyncUnsync INTEGER,
ttaIrigIrigTime DisplayString (SIZE(0..255))
}
ttaIrigSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaIrigStatusEntry 1 }
ttaIrigSyncUnsync OBJECT-TYPE
SYNTAX INTEGER{
unsync(1),
sync(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" IRIG is Sync or not "
::= { ttaIrigStatusEntry 2 }
ttaIrigIrigTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" IRIG Time "
::= { ttaIrigStatusEntry 3 }
--
--Channel Status Table
--
ttaChStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaChStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Channel Status Table "
::= { ttaSysStatusTable 5 }
ttaChStatusEntry OBJECT-TYPE
SYNTAX TtaChStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Channel Status Table "
INDEX { ttaChStatusSlotIndex , ttaChStatusChIndex }
::= { ttaChStatusTable 1 }
TtaChStatusEntry ::= SEQUENCE {
ttaChStatusSlotIndex LargeSlotIndex,
ttaChStatusChIndex INTEGER,
ttaChStatusPickUpCnt INTEGER,
ttaChStatusCrcErrCnt INTEGER,
ttaChStatusIdStatus INTEGER
}
ttaChStatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaChStatusEntry 1 }
ttaChStatusChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaChStatusEntry 2 }
ttaChStatusPickUpCnt OBJECT-TYPE
SYNTAX INTEGER(0..255) --//RIKER2021 SilverCreek
-- SYNTAX INTEGER{
-- na(256)
-- }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Pick Up Cnt. "
::= { ttaChStatusEntry 3 }
ttaChStatusCrcErrCnt OBJECT-TYPE
SYNTAX INTEGER(0..255) --//RIKER2021 SilverCreek
-- SYNTAX INTEGER{
-- na(256)
-- }
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CRC Error Cnt. "
::= { ttaChStatusEntry 4 }
ttaChStatusIdStatus OBJECT-TYPE
SYNTAX INTEGER{
match(1),
mismatch(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ID Status "
::= { ttaChStatusEntry 5 }
--
-- Round Trip Test Results Table
--
ttaRTTestResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaRTTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Round Trip Test Results Table "
::= { tta-card 4 }
ttaRTTestResultEntry OBJECT-TYPE
SYNTAX TtaRTTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Round Trip Test Results Table "
INDEX { ttaTestSlotIndex , ttaTestChIndex }
::= { ttaRTTestResultTable 1 }
TtaRTTestResultEntry ::= SEQUENCE {
ttaTestSlotIndex LargeSlotIndex,
ttaTestChIndex INTEGER,
ttaTestTriggerTime DisplayString (SIZE(0..255)),
ttaTestResponseTime DisplayString (SIZE(0..255)),
ttaTestRTrip DisplayString (SIZE(0..255))
}
ttaTestSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaRTTestResultEntry 1 }
ttaTestChIndex OBJECT-TYPE
SYNTAX INTEGER {
p1-1(1),
p1-2(2),
p1-3(3),
p2-1(4),
p2-2(5),
p2-3(6),
p3-1(7),
p3-2(8),
p3-3(9),
p4-1(10),
p4-2(11),
p4-3(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Channel p1-1 to p4-3, Total 12 channels "
::= { ttaRTTestResultEntry 2 }
ttaTestTriggerTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Trigger Time Stamp "
::= { ttaRTTestResultEntry 3 }
ttaTestResponseTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Response Time Stamp "
::= { ttaRTTestResultEntry 4 }
ttaTestRTrip OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" R-Trip (ms) "
::= { ttaRTTestResultEntry 5 }
--
--PCM Rx Address Table
--
-- ttaPCMRxAddTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TtaPCMRxAddEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- " The PCM Rx Address Table "
-- ::= { ttaSysStatusTable 6 }
-- ttaPCMRxAddEntry OBJECT-TYPE
-- SYNTAX TtaPCMRxAddEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- " An entry in the PCM Rx Address Table "
-- INDEX {ttaPCMRxAddSlotIndex, ttaPCMRxAddChanIndex }
-- ::= { ttaPCMRxAddTable 1 }
-- TtaPCMRxAddEntry ::= SEQUENCE {
-- ttaPCMRxAddSlotIndex LargeSlotIndex,
-- ttaPCMRxAddChanIndex INTEGER,
-- ttaPCMRxAddAddress INTEGER
-- }
-- ttaPCMRxAddSlotIndex OBJECT-TYPE
-- SYNTAX LargeSlotIndex
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Slot 1~12, total 12 slots."
-- ::= { ttaPCMRxAddEntry 1 }
-- ttaPCMRxAddChanIndex OBJECT-TYPE
-- SYNTAX INTEGER {
-- channel1(1),
-- channel2(2),
-- channel3(3),
-- channel4(4),
-- channel5(5),
-- channel6(6),
-- channel7(7),
-- channel8(8),
-- channel9(9),
-- channel10(10),
-- channel11(11),
-- channel12(12)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " Channel 1 to 12, Total 12 channels "
-- ::= { ttaPCMRxAddEntry 2 }
-- ttaPCMRxAddAddress OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- " PCM Rx Address "
-- ::= { ttaPCMRxAddEntry 3 }
--
-- Card Control Table
--
ttaCardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA Card Control Table "
::= { tta-card 5 }
ttaCardControlEntry OBJECT-TYPE
SYNTAX TtaCardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA Card Control Table "
INDEX { ttaCardIndex }
::= { ttaCardControlTable 1 }
TtaCardControlEntry ::= SEQUENCE {
ttaCardIndex LargeSlotIndex,
ttaReset INTEGER,
ttaLoadDefault INTEGER
}
ttaCardIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaCardControlEntry 1 }
ttaReset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Reset TTA card "
::= { ttaCardControlEntry 2 }
ttaLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
na(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Load default "
::= { ttaCardControlEntry 3 }
--
-- TTA System Information Table
--
ttaSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TtaSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The TTA System Information Table "
::= { tta-card 6 }
ttaSystemInfoEntry OBJECT-TYPE
SYNTAX TtaSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the TTA System Information Table "
INDEX { ttaSystemInfoSlotIndex }
::= { ttaSystemInfoTable 1 }
TtaSystemInfoEntry ::= SEQUENCE {
ttaSystemInfoSlotIndex LargeSlotIndex,
ttaSystemInfoPROMVersion DisplayString,
ttaSystemInfoHardwareVersion DisplayString,
ttaSystemInfoFpgaVersion DisplayString,
ttaSystemInfoBank1Version DisplayString,
ttaSystemInfoBank2Version DisplayString,
ttaSystemInfoActiveBank INTEGER
}
ttaSystemInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { ttaSystemInfoEntry 1 }
ttaSystemInfoPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TTA PROM Version "
::= { ttaSystemInfoEntry 2 }
ttaSystemInfoHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TTA Hardware Version "
::= { ttaSystemInfoEntry 3 }
ttaSystemInfoFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FPGA Version "
::= { ttaSystemInfoEntry 4 }
ttaSystemInfoBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bank-1 Version "
::= { ttaSystemInfoEntry 5 }
ttaSystemInfoBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bank-2 Version "
::= { ttaSystemInfoEntry 6}
ttaSystemInfoActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Active Bank 1/2 "
::= { ttaSystemInfoEntry 7 }
ttaTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total cards of TTA "
::= { tta-card 100 }
--======================================================================--
--======================================================================--
-- M4TE Card MIB
--======================================================================--
--======================================================================--
--
-- E1/T1 mode Table
--
m4tePortModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4tePortModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE port mode table."
::= { m4teCard 1 }
m4tePortModeEntry OBJECT-TYPE
SYNTAX M4tePortModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE port mode entry."
INDEX { m4tePMSlotIndex , m4tePMPortIndex }
::= { m4tePortModeTable 1 }
M4tePortModeEntry ::= SEQUENCE {
m4tePMSlotIndex SmallSlotIndex,
m4tePMPortIndex FourPortID,
m4tePortMode INTEGER,
m4tePortState INTEGER
}
m4tePMSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4tePortModeEntry 1 }
m4tePMPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4tePortModeEntry 2 }
m4tePortMode OBJECT-TYPE
SYNTAX INTEGER {
e1Imp120Ohm(1),
t1Mode(2),
e1Imp75Ohm(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"M4TE port mode: if map exist, can not change from T1 to E1 or E1 to T1"
::= { m4tePortModeEntry 3 }
m4tePortState OBJECT-TYPE
SYNTAX INTEGER {
cleared(1),
mapExist(2),
protectionExist(3),
mappedAndProtected(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port state"
::= { m4tePortModeEntry 4 }
--
-- M4TE E1 Line Control Table
--
m4E1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE E1 line control table."
::= { m4teCard 2 }
m4E1LineControlEntry OBJECT-TYPE
SYNTAX M4E1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE E1 line control entry."
INDEX { m4E1LCSlotIndex , m4E1LCPortIndex }
::= { m4E1LineControlTable 1 }
M4E1LineControlEntry ::= SEQUENCE {
m4E1LCSlotIndex SmallSlotIndex,
m4E1LCPortIndex FourPortID,
m4E1LineFrame INTEGER,
m4E1LineCoding INTEGER,
m4E1Interface INTEGER,
m4E1FDL INTEGER,
m4E1FDLSabit INTEGER,
m4E1AIS INTEGER,
m4E1RAI INTEGER,
m4E1CRC INTEGER,
m4E1IdleCode INTEGER,
m4E1CASMode INTEGER,
m4E1SignallingMode INTEGER,
m4E1CGA INTEGER,
m4E1OutOfService INTEGER,
m4E1Protect INTEGER,
m4E1Master INTEGER
}
m4E1LCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4E1LineControlEntry 1 }
m4E1LCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4E1LineControlEntry 2 }
m4E1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { m4E1LineControlEntry 3 }
m4E1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
hdb3(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { m4E1LineControlEntry 4 }
m4E1Interface OBJECT-TYPE
SYNTAX INTEGER {
twistedPair(1),
coaxialCable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface indicates that E1 line use 75/120 Ohm Cable."
::= { m4E1LineControlEntry 5 }
m4E1FDL OBJECT-TYPE
SYNTAX INTEGER {
--fdl(1),
off(2),
hdlc(3),
ssm(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link ON/OFF"
::= { m4E1LineControlEntry 6 }
m4E1FDLSabit OBJECT-TYPE
SYNTAX INTEGER {
sa4(1),
sa5(2),
sa6(3),
sa7(4),
sa8(5),
sa4and5(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Facility Data Link use Sax bit"
::= { m4E1LineControlEntry 7 }
m4E1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 line Alarm Indication Signal."
::= { m4E1LineControlEntry 8 }
m4E1RAI OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RAI-ON indicates that RAI (Remote Alarm Indication) ON."
::= { m4E1LineControlEntry 9 }
m4E1CRC OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 Cycle Redundancy Check ON/OFF"
::= { m4E1LineControlEntry 10 }
m4E1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { m4E1LineControlEntry 11 }
m4E1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { m4E1LineControlEntry 12 }
m4E1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
-- cd01(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS or CD01"
::= { m4E1LineControlEntry 13 }
m4E1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { m4E1LineControlEntry 14 }
m4E1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { m4E1LineControlEntry 15 }
m4E1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { m4E1LineControlEntry 16 }
m4E1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { m4E1LineControlEntry 17 }
--
-- M4TE T1 Line Control Table
--
m4T1LineControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4T1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE T1 line control table."
::= { m4teCard 3 }
m4T1LineControlEntry OBJECT-TYPE
SYNTAX M4T1LineControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE T1 line control entry."
INDEX { m4T1LCSlotIndex , m4T1LCPortIndex }
::= { m4T1LineControlTable 1 }
M4T1LineControlEntry ::= SEQUENCE {
m4T1LCSlotIndex SmallSlotIndex,
m4T1LCPortIndex FourPortID,
m4T1LineFrame INTEGER,
m4T1LineCoding INTEGER,
m4T1Interface INTEGER,
m4T1LineBuildOut INTEGER,
m4T1Equalizer INTEGER,
m4T1AIS INTEGER,
m4T1YEL INTEGER,
m4T1Inband INTEGER,
m4T1IdleCode INTEGER,
m4T1CASMode INTEGER,
m4T1SignallingMode INTEGER,
m4T1CGA INTEGER,
m4T1OutOfService INTEGER,
m4T1FDL INTEGER,
m4T1Protect INTEGER,
m4T1Master INTEGER
}
m4T1LCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4T1LineControlEntry 1 }
m4T1LCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4T1LineControlEntry 2 }
m4T1LineFrame OBJECT-TYPE
SYNTAX INTEGER {
d4(1),
esf(2),
esfT1403(3),
none(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line frame format"
::= { m4T1LineControlEntry 3 }
m4T1LineCoding OBJECT-TYPE
SYNTAX INTEGER {
ami(1),
b8zs(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding type"
::= { m4T1LineControlEntry 4 }
m4T1Interface OBJECT-TYPE
SYNTAX INTEGER {
longHaul(1),
shortHaul(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Interface indicates that T1 line use Long/Short haul."
::= { m4T1LineControlEntry 5 }
m4T1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
lbo0dB(1),
lboNeg7p5dB(2),
lboNeg15dB(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line build out."
::= { m4T1LineControlEntry 6 }
m4T1Equalizer OBJECT-TYPE
SYNTAX INTEGER {
equ0to110Ft(1),
equ110to220ft(2),
equ220to330ft(3),
equ330to440ft(4),
equ440to550ft(5),
equ550to660ft(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line equalizer."
::= { m4T1LineControlEntry 7 }
m4T1AIS OBJECT-TYPE
SYNTAX INTEGER {
frame(1),
-- unframe(2),
off(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line Alarm Indication Signal."
::= { m4T1LineControlEntry 8 }
m4T1YEL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"YEL-ON indicates that yellow alarm ON."
::= { m4T1LineControlEntry 9 }
m4T1Inband OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 line inband ON/OFF"
::= { m4T1LineControlEntry 10 }
m4T1IdleCode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Idle Code Value"
::= { m4T1LineControlEntry 11 }
m4T1CASMode OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CAS or CCS"
::= { m4T1LineControlEntry 12 }
m4T1SignallingMode OBJECT-TYPE
SYNTAX INTEGER {
trans(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TRANS"
::= { m4T1LineControlEntry 13 }
m4T1CGA OBJECT-TYPE
SYNTAX INTEGER {
norm(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Method used to signal the Carrier Group Alarm state
to the other end of the selected link."
::= { m4T1LineControlEntry 14 }
m4T1OutOfService OBJECT-TYPE
SYNTAX INTEGER {
busy(1),
idle(2),
ais(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When NORM (CGA) is select, the parameter determines the
state of the A, B signaling bits during the
Out-of-Service periods."
::= { m4T1LineControlEntry 15 }
m4T1FDL OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T1 Facility Data Link ON/OFF"
::= { m4T1LineControlEntry 16 }
m4T1Protect OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
circuit(2),
line(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"disable or enable."
::= { m4T1LineControlEntry 17 }
m4T1Master OBJECT-TYPE
SYNTAX INTEGER {
xxxx(1),
slave(2),
master(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"master or slave"
::= { m4T1LineControlEntry 18 }
--
-- User Current Performance Table
--
m4teUserCurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teUserCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Current Performance Table"
::= { m4teCard 4 }
m4teUserCurrPerfEntry OBJECT-TYPE
SYNTAX M4teUserCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User current performance entry"
INDEX { m4teUCPSlotIndex , m4teUCPPortIndex }
::= { m4teUserCurrPerfTable 1 }
M4teUserCurrPerfEntry ::= SEQUENCE {
m4teUCPSlotIndex SmallSlotIndex,
m4teUCPPortIndex FourPortID,
m4teUserCurrPerfES INTEGER,
m4teUserCurrPerfSES INTEGER,
m4teUserCurrPerfBES INTEGER,
m4teUserCurrPerfUAS INTEGER,
m4teUserCurrPerfCSS INTEGER,
m4teUserCurrPerfBPV INTEGER,
m4teUserCurrPerfDMlofc INTEGER,
m4teUserCurr15MinElapsed INTEGER,
m4teUserValid15MinIntv INTEGER
}
m4teUCPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teUserCurrPerfEntry 1 }
m4teUCPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teUserCurrPerfEntry 2 }
m4teUserCurrPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teUserCurrPerfEntry 3 }
m4teUserCurrPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teUserCurrPerfEntry 4 }
m4teUserCurrPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teUserCurrPerfEntry 5 }
m4teUserCurrPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teUserCurrPerfEntry 6 }
m4teUserCurrPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CS Error Counter "
::= { m4teUserCurrPerfEntry 7 }
m4teUserCurrPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teUserCurrPerfEntry 8 }
m4teUserCurrPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teUserCurrPerfEntry 9 }
m4teUserCurr15MinElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { m4teUserCurrPerfEntry 11 }
m4teUserValid15MinIntv OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { m4teUserCurrPerfEntry 12 }
--
-- User Interval Performance Table
--
m4teUserIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teUserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Interval Performance Table"
::= { m4teCard 5 }
m4teUserIntvPerfEntry OBJECT-TYPE
SYNTAX M4teUserIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User interval performance entry"
INDEX { m4teUIPSlotIndex , m4teUIPPortIndex , m4teUserIntvPerfNumber }
::= { m4teUserIntvPerfTable 1 }
M4teUserIntvPerfEntry ::= SEQUENCE {
m4teUIPSlotIndex SmallSlotIndex,
m4teUIPPortIndex FourPortID,
m4teUserIntvPerfNumber INTEGER,
m4teUserIntvPerfES INTEGER,
m4teUserIntvPerfSES INTEGER,
m4teUserIntvPerfBES INTEGER,
m4teUserIntvPerfUAS INTEGER,
m4teUserIntvPerfCSS INTEGER,
m4teUserIntvPerfBPV INTEGER,
m4teUserIntvPerfDMlofc INTEGER
}
m4teUIPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teUserIntvPerfEntry 1 }
m4teUIPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teUserIntvPerfEntry 2 }
m4teUserIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interval Index"
::= { m4teUserIntvPerfEntry 3 }
m4teUserIntvPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teUserIntvPerfEntry 4 }
m4teUserIntvPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teUserIntvPerfEntry 5 }
m4teUserIntvPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teUserIntvPerfEntry 6 }
m4teUserIntvPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teUserIntvPerfEntry 7 }
m4teUserIntvPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teUserIntvPerfEntry 8 }
m4teUserIntvPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teUserIntvPerfEntry 9 }
m4teUserIntvPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teUserIntvPerfEntry 10 }
--
-- User Total Performance Table
--
m4teUserTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teUserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User Total Performance Table"
::= { m4teCard 6 }
m4teUserTotalPerfEntry OBJECT-TYPE
SYNTAX M4teUserTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User total performance entry"
INDEX { m4teUTPSlotIndex , m4teUTPPortIndex }
::= { m4teUserTotalPerfTable 1 }
M4teUserTotalPerfEntry ::= SEQUENCE {
m4teUTPSlotIndex SmallSlotIndex,
m4teUTPPortIndex FourPortID,
m4teUserTotalPerfES INTEGER,
m4teUserTotalPerfSES INTEGER,
m4teUserTotalPerfBES INTEGER,
m4teUserTotalPerfUAS INTEGER,
m4teUserTotalPerfCSS INTEGER,
m4teUserTotalPerfBPV INTEGER,
m4teUserTotalPerfDMlofc INTEGER
}
m4teUTPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teUserTotalPerfEntry 1 }
m4teUTPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teUserTotalPerfEntry 2 }
m4teUserTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teUserTotalPerfEntry 3 }
m4teUserTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teUserTotalPerfEntry 4 }
m4teUserTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teUserTotalPerfEntry 5 }
m4teUserTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teUserTotalPerfEntry 6 }
m4teUserTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teUserTotalPerfEntry 7 }
m4teUserTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teUserTotalPerfEntry 8 }
m4teUserTotalPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teUserTotalPerfEntry 9 }
--
-- User Seven Days Performance Table
--
m4teUser7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teUser7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 Days Performance Table"
::= { m4teCard 7 }
m4teUser7DaysPerfEntry OBJECT-TYPE
SYNTAX M4teUser7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User 7 days performance table"
INDEX { m4teUDPSlotIndex , m4teUDPPortIndex , m4teUserDaysIndex }
::= { m4teUser7DaysPerfTable 1 }
M4teUser7DaysPerfEntry ::= SEQUENCE {
m4teUDPSlotIndex SmallSlotIndex,
m4teUDPPortIndex FourPortID,
m4teUserDaysIndex INTEGER,
m4teUserDateStrIndex DisplayString,
m4teUser7DaysPerfES INTEGER,
m4teUser7DaysPerfSES INTEGER,
m4teUser7DaysPerfBES INTEGER,
m4teUser7DaysPerfUAS INTEGER,
m4teUser7DaysPerfCSS INTEGER,
m4teUser7DaysPerfDMlofc INTEGER,
m4teUser7DaysPerfBPV INTEGER
}
m4teUDPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teUser7DaysPerfEntry 1 }
m4teUDPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teUser7DaysPerfEntry 2 }
m4teUserDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { m4teUser7DaysPerfEntry 3 }
m4teUserDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { m4teUser7DaysPerfEntry 4 }
m4teUser7DaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teUser7DaysPerfEntry 5 }
m4teUser7DaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teUser7DaysPerfEntry 6 }
m4teUser7DaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teUser7DaysPerfEntry 7 }
m4teUser7DaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teUser7DaysPerfEntry 8 }
m4teUser7DaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teUser7DaysPerfEntry 9 }
m4teUser7DaysPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teUser7DaysPerfEntry 10 }
m4teUser7DaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teUser7DaysPerfEntry 11 }
--
-- Line Current Performance Table
--
m4teLineCurrPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLineCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Current Performance Table"
::= { m4teCard 8 }
m4teLineCurrPerfEntry OBJECT-TYPE
SYNTAX M4teLineCurrPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line current performance entry"
INDEX { m4teLCPSlotIndex , m4teLCPPortIndex }
::= { m4teLineCurrPerfTable 1 }
M4teLineCurrPerfEntry ::= SEQUENCE {
m4teLCPSlotIndex SmallSlotIndex,
m4teLCPPortIndex FourPortID,
m4teLineCurrPerfES INTEGER,
m4teLineCurrPerfSES INTEGER,
m4teLineCurrPerfBES INTEGER,
m4teLineCurrPerfUAS INTEGER,
m4teLineCurrPerfCSS INTEGER,
m4teLineCurrPerfBPV INTEGER,
m4teLineCurrPerfDMlofc INTEGER,
m4teLineCurr15MinElapsed INTEGER,
m4teLineValid15MinIntv INTEGER
}
m4teLCPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLineCurrPerfEntry 1 }
m4teLCPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLineCurrPerfEntry 2 }
m4teLineCurrPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ESS Error Counter "
::= { m4teLineCurrPerfEntry 3 }
m4teLineCurrPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teLineCurrPerfEntry 4 }
m4teLineCurrPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teLineCurrPerfEntry 5 }
m4teLineCurrPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teLineCurrPerfEntry 6 }
m4teLineCurrPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teLineCurrPerfEntry 7 }
m4teLineCurrPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teLineCurrPerfEntry 8 }
m4teLineCurrPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teLineCurrPerfEntry 9 }
m4teLineCurr15MinElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 15-minute time elapsed"
::= { m4teLineCurrPerfEntry 11 }
m4teLineValid15MinIntv OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Current 1-day Valid 15-min interval"
::= { m4teLineCurrPerfEntry 12 }
--
-- Line Interval Performance Table
--
m4teLineIntvPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Interval Performance Table"
::= { m4teCard 9 }
m4teLineIntvPerfEntry OBJECT-TYPE
SYNTAX M4teLineIntvPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line interval performance entry"
INDEX { m4teLIPSlotIndex , m4teLIPPortIndex , m4teLineIntvPerfNumber }
::= { m4teLineIntvPerfTable 1 }
M4teLineIntvPerfEntry ::= SEQUENCE {
m4teLIPSlotIndex SmallSlotIndex,
m4teLIPPortIndex FourPortID,
m4teLineIntvPerfNumber INTEGER,
m4teLineIntvPerfES INTEGER,
m4teLineIntvPerfSES INTEGER,
m4teLineIntvPerfBES INTEGER,
m4teLineIntvPerfUAS INTEGER,
m4teLineIntvPerfCSS INTEGER,
m4teLineIntvPerfBPV INTEGER,
m4teLineIntvPerfDMlofc INTEGER,
m4teLineIntvAvailable INTEGER
}
m4teLIPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLineIntvPerfEntry 1 }
m4teLIPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLineIntvPerfEntry 2 }
m4teLineIntvPerfNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Index "
::= { m4teLineIntvPerfEntry 3 }
m4teLineIntvPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teLineIntvPerfEntry 4 }
m4teLineIntvPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teLineIntvPerfEntry 5 }
m4teLineIntvPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teLineIntvPerfEntry 6 }
m4teLineIntvPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teLineIntvPerfEntry 7 }
m4teLineIntvPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teLineIntvPerfEntry 8 }
m4teLineIntvPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teLineIntvPerfEntry 9 }
m4teLineIntvPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teLineIntvPerfEntry 10 }
m4teLineIntvAvailable OBJECT-TYPE
SYNTAX INTEGER {
available(1),
na(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Interval Available "
::= { m4teLineIntvPerfEntry 11 }
--
-- Line Total Performance Table
--
m4teLineTotalPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line Total Performance Table"
::= { m4teCard 10 }
m4teLineTotalPerfEntry OBJECT-TYPE
SYNTAX M4teLineTotalPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line total performance table"
INDEX { m4teLTPSlotIndex , m4teLTPPortIndex }
::= { m4teLineTotalPerfTable 1 }
M4teLineTotalPerfEntry ::= SEQUENCE {
m4teLTPSlotIndex SmallSlotIndex,
m4teLTPPortIndex FourPortID,
m4teLineTotalPerfES INTEGER,
m4teLineTotalPerfSES INTEGER,
m4teLineTotalPerfBES INTEGER,
m4teLineTotalPerfUAS INTEGER,
m4teLineTotalPerfCSS INTEGER,
m4teLineTotalPerfBPV INTEGER,
m4teLineTotalPerfDMlofc INTEGER
}
m4teLTPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLineTotalPerfEntry 1 }
m4teLTPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLineTotalPerfEntry 2 }
m4teLineTotalPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teLineTotalPerfEntry 3 }
m4teLineTotalPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teLineTotalPerfEntry 4 }
m4teLineTotalPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teLineTotalPerfEntry 5 }
m4teLineTotalPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teLineTotalPerfEntry 6 }
m4teLineTotalPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teLineTotalPerfEntry 7 }
m4teLineTotalPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teLineTotalPerfEntry 8 }
m4teLineTotalPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teLineTotalPerfEntry 9 }
--
-- Line Seven Days Performance Table
--
m4teLine7DaysPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLine7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 Days Performance Table"
::= { m4teCard 11 }
m4teLine7DaysPerfEntry OBJECT-TYPE
SYNTAX M4teLine7DaysPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Line 7 days performance entry"
INDEX { m4teLDPSlotIndex , m4teLDPPortIndex , m4teLineDaysIndex }
::= { m4teLine7DaysPerfTable 1 }
M4teLine7DaysPerfEntry ::= SEQUENCE {
m4teLDPSlotIndex SmallSlotIndex,
m4teLDPPortIndex FourPortID,
m4teLineDaysIndex INTEGER,
m4teLineDateStrIndex DisplayString,
m4teLine7DaysPerfES INTEGER,
m4teLine7DaysPerfSES INTEGER,
m4teLine7DaysPerfBES INTEGER,
m4teLine7DaysPerfUAS INTEGER,
m4teLine7DaysPerfCSS INTEGER,
m4teLine7DaysPerfDMlofc INTEGER,
m4teLine7DaysPerfBPV INTEGER
}
m4teLDPSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLine7DaysPerfEntry 1 }
m4teLDPPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLine7DaysPerfEntry 2 }
m4teLineDaysIndex OBJECT-TYPE
SYNTAX INTEGER (1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days index "
::= { m4teLine7DaysPerfEntry 3 }
m4teLineDateStrIndex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Seven Days String "
::= { m4teLine7DaysPerfEntry 4 }
m4teLine7DaysPerfES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ES Error Counter "
::= { m4teLine7DaysPerfEntry 5 }
m4teLine7DaysPerfSES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" SES Error Counter "
::= { m4teLine7DaysPerfEntry 6 }
m4teLine7DaysPerfBES OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BES Error Counter "
::= { m4teLine7DaysPerfEntry 7 }
m4teLine7DaysPerfUAS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" UAS Error Counter "
::= { m4teLine7DaysPerfEntry 8 }
m4teLine7DaysPerfCSS OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CSS Error Counter "
::= { m4teLine7DaysPerfEntry 9 }
m4teLine7DaysPerfDMlofc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" E1 DM or T1 LOFC error Counter "
::= { m4teLine7DaysPerfEntry 10 }
m4teLine7DaysPerfBPV OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BPV Error Counter "
::= { m4teLine7DaysPerfEntry 11 }
--
-- Alarm Queue Table
--
m4teAlarmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teAlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Queue Table "
::= { m4teCard 12 }
m4teAlarmQueueEntry OBJECT-TYPE
SYNTAX M4teAlarmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm queue entry"
INDEX { m4teAQSlotIndex , m4teAQPortIndex , m4teAlarmQueueIndex }
::= { m4teAlarmQueueTable 1 }
M4teAlarmQueueEntry ::= SEQUENCE {
m4teAQSlotIndex SmallSlotIndex,
m4teAQPortIndex FourPortID,
m4teAlarmQueueIndex INTEGER,
m4teAlarmQueueString DisplayString
}
m4teAQSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teAlarmQueueEntry 1 }
m4teAQPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teAlarmQueueEntry 2 }
m4teAlarmQueueIndex OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Alarm Queue Index(1-40)"
::= { m4teAlarmQueueEntry 3 }
m4teAlarmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { m4teAlarmQueueEntry 4 }
--
-- Alarm History Table
--
m4teAlarmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm History Table"
::= { m4teCard 13 }
m4teAlarmHistoryEntry OBJECT-TYPE
SYNTAX M4teAlarmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm history entry"
INDEX { m4teAHSlotIndex , m4teAHPortIndex , m4teAlarmHistoryIndex }
::= { m4teAlarmHistoryTable 1 }
M4teAlarmHistoryEntry ::= SEQUENCE {
m4teAHSlotIndex SmallSlotIndex,
m4teAHPortIndex FourPortID,
m4teAlarmHistoryIndex INTEGER,
m4teThreshold INTEGER,
m4teCurrentState INTEGER,
m4teCurrentCount INTEGER,
m4teAlarm AlarmSeverity
}
m4teAHSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teAlarmHistoryEntry 1 }
m4teAHPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teAlarmHistoryEntry 2 }
m4teAlarmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER {
raiYelLine(1),
aisLine(2),
losLine(3),
lofLine(4),
bpvLine(5),
essLine(6),
uasLine(7),
cssLine(8),
tpca(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Index "
::= { m4teAlarmHistoryEntry 3 }
m4teThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Threshold Value "
::= { m4teAlarmHistoryEntry 4 }
m4teCurrentState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current State"
::= { m4teAlarmHistoryEntry 5 }
m4teCurrentCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm History Current Count "
::= { m4teAlarmHistoryEntry 6 }
m4teAlarm OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm History Alarm State"
::= { m4teAlarmHistoryEntry 7 }
--
-- Line Availability Table
--
m4teLineAvailTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE line control table."
::= { m4teCard 14 }
m4teLineAvailEntry OBJECT-TYPE
SYNTAX M4teLineAvailEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE line control entry."
INDEX { m4teLASlotIndex , m4teLAPortIndex }
::= { m4teLineAvailTable 1 }
M4teLineAvailEntry ::= SEQUENCE {
m4teLASlotIndex SmallSlotIndex,
m4teLAPortIndex FourPortID,
m4teAvailableSeconds DisplayString,
m4teUnavailableSeconds DisplayString,
m4teLineAvailability DisplayString
}
m4teLASlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLineAvailEntry 1 }
m4teLAPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLineAvailEntry 2 }
m4teAvailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Seconds"
::= { m4teLineAvailEntry 3 }
m4teUnavailableSeconds OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Unavailable Seconds"
::= { m4teLineAvailEntry 4 }
m4teLineAvailability OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Available Percentage"
::= { m4teLineAvailEntry 5 }
--
-- Alarm Control Table
--
m4teAlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE alarm control table."
::= { m4teCard 15 }
m4teAlarmControlEntry OBJECT-TYPE
SYNTAX M4teAlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE alarm control table."
INDEX { m4teACSlotIndex , m4teACPortIndex }
::= { m4teAlarmControlTable 1 }
M4teAlarmControlEntry ::= SEQUENCE {
m4teACSlotIndex SmallSlotIndex,
m4teACPortIndex FourPortID,
m4teRaiYel AlarmSeverity,
m4teAIS AlarmSeverity,
m4teLOS AlarmSeverity,
m4teLOF AlarmSeverity,
m4teBPV AlarmSeverity,
m4teES AlarmSeverity,
m4teUAS AlarmSeverity,
m4teCSS AlarmSeverity,
m4teTCPA AlarmSeverity
}
m4teACSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teAlarmControlEntry 1 }
m4teACPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teAlarmControlEntry 2 }
m4teRaiYel OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E1 RAI or T1 YEL State"
::= { m4teAlarmControlEntry 3 }
m4teAIS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"AIS State"
::= { m4teAlarmControlEntry 4 }
m4teLOS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOS State"
::= { m4teAlarmControlEntry 5 }
m4teLOF OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LOF State"
::= { m4teAlarmControlEntry 6 }
m4teBPV OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BPV State"
::= { m4teAlarmControlEntry 7 }
m4teES OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ES State"
::= { m4teAlarmControlEntry 8 }
m4teUAS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UAS State"
::= { m4teAlarmControlEntry 9 }
m4teCSS OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CSS State"
::= { m4teAlarmControlEntry 10 }
m4teTCPA OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TCPA State"
::= { m4teAlarmControlEntry 11 }
--
-- Threshold Control Table
--
m4teThresholdCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE alarm control table."
::= { m4teCard 16 }
m4teThresholdCtrlEntry OBJECT-TYPE
SYNTAX M4teThresholdCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE alarm control entry."
INDEX { m4teTCSlotIndex , m4teTCPortIndex }
::= { m4teThresholdCtrlTable 1 }
M4teThresholdCtrlEntry ::= SEQUENCE {
m4teTCSlotIndex SmallSlotIndex,
m4teTCPortIndex FourPortID,
m4teThresholdBPV INTEGER,
m4teThresholdESS INTEGER,
m4teThresholdUAS INTEGER,
m4teThresholdCSS INTEGER,
m4teThresholdTCPA INTEGER
}
m4teTCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teThresholdCtrlEntry 1 }
m4teTCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teThresholdCtrlEntry 2 }
m4teThresholdBPV OBJECT-TYPE
SYNTAX INTEGER (5..9)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of BPV"
::= { m4teThresholdCtrlEntry 3 }
m4teThresholdESS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of ESS"
::= { m4teThresholdCtrlEntry 4 }
m4teThresholdUAS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of UAS"
::= { m4teThresholdCtrlEntry 5 }
m4teThresholdCSS OBJECT-TYPE
SYNTAX INTEGER (1..900)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of CS"
::= { m4teThresholdCtrlEntry 6 }
m4teThresholdTCPA OBJECT-TYPE
SYNTAX INTEGER (1..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Threshold of TCPA "
::= { m4teThresholdCtrlEntry 7 }
--
-- Line Diagnostic Control Table
--
m4teLineDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teLineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE line diagostic table."
::= { m4teCard 17 }
m4teLineDiagControlEntry OBJECT-TYPE
SYNTAX M4teLineDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE line diagostic entry."
INDEX { m4teDCSlotIndex , m4teDCPortIndex }
::= { m4teLineDiagControlTable 1 }
M4teLineDiagControlEntry ::= SEQUENCE {
m4teDCSlotIndex SmallSlotIndex,
m4teDCPortIndex FourPortID,
m4teLoopbackType INTEGER,
m4teLoopbackStatus INTEGER,
m4teBERTControl INTEGER,
m4teBERTStatus INTEGER,
m4teBERTElapseSeconds INTEGER,
m4teBERTErrorSeconds INTEGER,
m4teBERTErrorCounts INTEGER,
m4teInbandLoopbackPeriod INTEGER
}
m4teDCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teLineDiagControlEntry 1 }
m4teDCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teLineDiagControlEntry 2 }
m4teLoopbackType OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
localLoopback(2),
payloadLoopback(3),
lineLoopback(4),
e1RemotePLBactive(5),
e1RemoteLLBactive(6),
e1RemotePLBdeactive(7),
e1RemoteLLBdeactive(8),
t1RemoteLlbInbandActive(11),
t1RemotePlbAttActive(12),
t1RemotePlbAnsiActive(13),
t1RemoteLlbAnsiActive(14),
t1RemoteLlbInbandDeactive(15),
t1RemotePlbAttDeactive(16),
t1RemotePlbAnsiDeactive(17),
t1RemoteLlbAnsiDeactive(18)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"M4TE Loopback Type"
::= { m4teLineDiagControlEntry 3 }
m4teLoopbackStatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopbackNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE Loopback Status"
::= { m4teLineDiagControlEntry 4 }
m4teBERTControl OBJECT-TYPE
SYNTAX INTEGER {
bertDeactive(1),
bertActiveFull(2),
bertResetErrorCount(3),
bertInjectError(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"M4TE BERT (E1 PRBS or T1 QRSS) Control"
::= { m4teLineDiagControlEntry 5 }
m4teBERTStatus OBJECT-TYPE
SYNTAX INTEGER {
bertSync(1),
bertUnsync(2),
bertNotActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE BERT Status"
::= { m4teLineDiagControlEntry 6 }
m4teBERTElapseSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE BERT Elapse Seconds"
::= { m4teLineDiagControlEntry 7 }
m4teBERTErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE BERT Error Seconds"
::= { m4teLineDiagControlEntry 8 }
m4teBERTErrorCounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE BERT Error Counts"
::= { m4teLineDiagControlEntry 9 }
m4teInbandLoopbackPeriod OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"period(in seconds) of inband local, payload, or line loopback"
::= { m4teLineDiagControlEntry 10 }
--
-- Command Control Table
--
m4teCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE command control table."
::= { m4teCard 18 }
m4teCommandControlEntry OBJECT-TYPE
SYNTAX M4teCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE command control entry."
INDEX { m4teCCSlotIndex , m4teCCPortIndex }
::= { m4teCommandControlTable 1 }
M4teCommandControlEntry ::= SEQUENCE {
m4teCCSlotIndex SmallSlotIndex,
m4teCCPortIndex FourPortID,
m4teAlarmQueueReset INTEGER,
m4teUserPerfReset INTEGER,
m4teAlarmHistoryReset INTEGER,
m4teCardReset INTEGER,
m4teCardLoadDefault INTEGER
}
m4teCCSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teCommandControlEntry 1 }
m4teCCPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teCommandControlEntry 2 }
m4teAlarmQueueReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm Queue "
::= { m4teCommandControlEntry 3 }
m4teUserPerfReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset User Performance"
::= { m4teCommandControlEntry 4 }
m4teAlarmHistoryReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Alarm History"
::= { m4teCommandControlEntry 5 }
m4teCardReset OBJECT-TYPE
SYNTAX INTEGER {
no(0),
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reset Card"
::= { m4teCommandControlEntry 6 }
m4teCardLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0),
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Card Load Default"
::= { m4teCommandControlEntry 7 }
--
-- SYSTEM Information Table
--
m4teSystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE system information table."
::= { m4teCard 19 }
m4teSystemInfoEntry OBJECT-TYPE
SYNTAX M4teSystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE system information entry."
INDEX { m4teSISlotIndex }
::= { m4teSystemInfoTable 1 }
M4teSystemInfoEntry ::= SEQUENCE {
m4teSISlotIndex SmallSlotIndex,
m4teFirmwareVersion DisplayString,
m4teHardwareVersion DisplayString
}
m4teSISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teSystemInfoEntry 1 }
m4teFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware Version"
::= { m4teSystemInfoEntry 2 }
m4teHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware Version"
::= { m4teSystemInfoEntry 3 }
--
-- M4TE signaling convertion setup Table
--
m4teSigConvertSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teSigConvertSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE signaling convertion setup table."
::= { m4teCard 20 }
m4teSigConvertSetupEntry OBJECT-TYPE
SYNTAX M4teSigConvertSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"M4TE signaling convertion setup entry."
INDEX { m4teScSlotIndex , m4teScPortIndex , m4teScTsIndex }
::= { m4teSigConvertSetupTable 1 }
M4teSigConvertSetupEntry ::= SEQUENCE {
m4teScSlotIndex SmallSlotIndex,
m4teScPortIndex FourPortID,
m4teScTsIndex INTEGER,
m4teScTsType INTEGER,
m4teScConvertionTable INTEGER
}
m4teScSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teSigConvertSetupEntry 1 }
m4teScPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE port"
::= { m4teSigConvertSetupEntry 2 }
m4teScTsIndex OBJECT-TYPE
SYNTAX INTEGER (1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TS index"
::= { m4teSigConvertSetupEntry 3 }
m4teScTsType OBJECT-TYPE
SYNTAX INTEGER {
data(1),
voice(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"TS type"
::= { m4teSigConvertSetupEntry 4 }
m4teScConvertionTable OBJECT-TYPE
SYNTAX INTEGER {
noConvert(1),
table1(2),
table2(3),
table3(4),
table4(5),
table5(6),
table6(7),
table7(8),
table8(9),
table9(10),
table10(11),
table11(12),
table12(13),
table13(14),
table14(15),
table15(16),
table16(17)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"unsing table X"
::= { m4teSigConvertSetupEntry 5 }
--
-- M4TE Customer Information Table
--
m4teCustomerInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF M4teCustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Customer Information table."
::= { m4teCard 99 }
m4teCustomerInfoEntry OBJECT-TYPE
SYNTAX M4teCustomerInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Customer Information entry."
INDEX { m4teCISlotIndex , m4teCIPortIndex }
::= { m4teCustomerInfoTable 1 }
M4teCustomerInfoEntry ::= SEQUENCE {
m4teCISlotIndex SmallSlotIndex,
m4teCIPortIndex FourPortID,
m4teCICustomerInfo DisplayString
}
m4teCISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"M4TE slot"
::= { m4teCustomerInfoEntry 1 }
m4teCIPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port number"
::= { m4teCustomerInfoEntry 2 }
m4teCICustomerInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64) )
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Customer information"
::= { m4teCustomerInfoEntry 3 }
m4teTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of M4TE"
::= { m4teCard 100 }
--======================================================================--
--======================================================================--
-- dte6-card MIB
--======================================================================--
--======================================================================--
--
-- DTE6 Mode Table
--
dte6ModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6ModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dte6-card 1 }
dte6ModeEntry OBJECT-TYPE
SYNTAX Dte6ModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { dte6ModeSlotIndex }
::= { dte6ModeTable 1 }
Dte6ModeEntry ::= SEQUENCE {
dte6ModeSlotIndex LargeSlotIndex,
dte6ModeCardMode INTEGER
}
dte6ModeSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6ModeEntry 1 }
dte6ModeCardMode OBJECT-TYPE
SYNTAX INTEGER {
m1(1),
m2(2),
m3(3),
m4(4),
m5(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Card Mode"
::= { dte6ModeEntry 2 }
--
-- DTE6 Configuration
--
dte6ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Interface Configuration table."
::= { dte6-card 2 }
dte6ConfigEntry OBJECT-TYPE
SYNTAX Dte6ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Configuration table."
INDEX { dte6CfgSlotIndex , dte6CfgPortIndex }
::= { dte6ConfigTable 1 }
Dte6ConfigEntry ::= SEQUENCE {
dte6CfgSlotIndex LargeSlotIndex,
dte6CfgPortIndex SixPortID,
dte6CfgInterface INTEGER,
dte6CfgMux INTEGER,
dte6CfgSyncMode INTEGER,
dte6CfgRate INTEGER,
dte6CfgBitPosition INTEGER,
dte6CfgClockPolarity INTEGER,
dte6CfgDataPolarity INTEGER,
dte6CfgRTS INTEGER,
dte6CfgTTM INTEGER,
dte6CfgBitPosition0Used INTEGER,
dte6CfgBitPosition1Used INTEGER,
dte6CfgBitPosition2Used INTEGER,
dte6CfgBitPosition3Used INTEGER,
dte6CfgBitPosition4Used INTEGER,
dte6CfgBitPosition5Used INTEGER,
dte6CfgBitPosition6Used INTEGER,
dte6CfgBitPosition7Used INTEGER,
dte6CfgWarrning DisplayString
}
dte6CfgSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6ConfigEntry 1 }
dte6CfgPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6ConfigEntry 2 }
dte6CfgInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs422(2),
x21(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Interface mode"
::= { dte6ConfigEntry 3 }
dte6CfgMux OBJECT-TYPE
SYNTAX INTEGER {
nonMux(1),
mux(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 MUX mode"
::= { dte6ConfigEntry 4 }
dte6CfgSyncMode OBJECT-TYPE
SYNTAX INTEGER {
async8(1),
async9(2),
async10(3),
async11(4),
async12(5),
sync(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Sync mode"
::= { dte6ConfigEntry 5 }
dte6CfgRate OBJECT-TYPE
SYNTAX INTEGER {
r0-6K(1),
r1-2K(2),
r2-4K(3),
r4-8K(4),
r9-6K(5),
r19-2K(6),
r38-4K(7),
r48K(8),
r64K(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Base Rate"
::= { dte6ConfigEntry 6 }
dte6CfgBitPosition OBJECT-TYPE
SYNTAX INTEGER {
position-0(1),
position-1(2),
position-2(3),
position-3(4),
position-4(5),
position-5(6),
position-6(7),
position-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Bit position"
::= { dte6ConfigEntry 7 }
dte6CfgClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Clock Polarity"
::= { dte6ConfigEntry 8 }
dte6CfgDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Data Polarity"
::= { dte6ConfigEntry 9 }
dte6CfgRTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 RTS Mode"
::= { dte6ConfigEntry 10 }
dte6CfgTTM OBJECT-TYPE
SYNTAX INTEGER {
ttmOff(1),
ttmOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 TTM Mode"
::= { dte6ConfigEntry 11 }
dte6CfgBitPosition0Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 0 Stream Position Used"
::= { dte6ConfigEntry 12 }
dte6CfgBitPosition1Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 1 Stream Position Used"
::= { dte6ConfigEntry 13 }
dte6CfgBitPosition2Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 2 Stream Position Used"
::= { dte6ConfigEntry 14 }
dte6CfgBitPosition3Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 3 Stream Position Used"
::= { dte6ConfigEntry 15 }
dte6CfgBitPosition4Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 4 Stream Position Used"
::= { dte6ConfigEntry 16 }
dte6CfgBitPosition5Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 5 Stream Position Used"
::= { dte6ConfigEntry 17 }
dte6CfgBitPosition6Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 6 Stream Position Used"
::= { dte6ConfigEntry 18 }
dte6CfgBitPosition7Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Bits 7 Stream Position Used"
::= { dte6ConfigEntry 19 }
dte6CfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 map setup warning"
::= { dte6ConfigEntry 20 }
--
-- DTE6 Status
--
dte6StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Status table."
::= { dte6-card 3}
dte6StatusEntry OBJECT-TYPE
SYNTAX Dte6StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Status table."
INDEX { dte6StatusSlotIndex , dte6StatusPortIndex }
::= { dte6StatusTable 1 }
Dte6StatusEntry ::= SEQUENCE {
dte6StatusSlotIndex LargeSlotIndex,
dte6StatusPortIndex SixPortID,
dte6StatusS1 INTEGER,
dte6StatusS3 INTEGER,
dte6StatusS4 INTEGER,
dte6StatusS6 INTEGER,
dte6StatusS8 INTEGER,
dte6StatusS9 INTEGER,
dte6StatusE4 INTEGER,
dte6StatusE5 INTEGER,
dte6StatusE6 INTEGER,
dte6StatusX INTEGER,
dte6StatusDteCTS INTEGER,
dte6StatusDteDCD INTEGER,
dte6StatusRTSloss INTEGER,
dte6StatusEXTCLKloss INTEGER,
dte6StatusDSRstatus INTEGER,
dte6StatusCTSstatus INTEGER,
dte6StatusDCDstatus INTEGER,
dte6StatusDTRstatus INTEGER,
dte6StatusRTSstatus INTEGER,
dte6StatusRemoteAlarm INTEGER,
dte6StatusFrameSync INTEGER,
dte6StatusRemoteS1 INTEGER,
dte6StatusRemoteS3 INTEGER,
dte6StatusRemoteS4 INTEGER,
dte6StatusRemoteS6 INTEGER,
dte6StatusRemoteS8 INTEGER,
dte6StatusRemoteS9 INTEGER,
dte6StatusRemoteE4 INTEGER,
dte6StatusRemoteE5 INTEGER,
dte6StatusRemoteE6 INTEGER,
dte6StatusRemoteX INTEGER
}
dte6StatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6StatusEntry 1 }
dte6StatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6StatusEntry 2 }
dte6StatusS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S1"
::= { dte6StatusEntry 3 }
dte6StatusS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S3"
::= { dte6StatusEntry 4 }
dte6StatusS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S4"
::= { dte6StatusEntry 5 }
dte6StatusS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S6"
::= { dte6StatusEntry 6 }
dte6StatusS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S8"
::= { dte6StatusEntry 7 }
dte6StatusS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit S9"
::= { dte6StatusEntry 8 }
dte6StatusE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit E4"
::= { dte6StatusEntry 9 }
dte6StatusE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit E5"
::= { dte6StatusEntry 10 }
dte6StatusE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit E6"
::= { dte6StatusEntry 11 }
dte6StatusX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rtswithFrameSYNC(12),
frameSYNC(13),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit X"
::= { dte6StatusEntry 12 }
dte6StatusDteCTS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit DTE CTS"
::= { dte6StatusEntry 13 }
dte6StatusDteDCD OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit DTE DCD"
::= { dte6StatusEntry 14 }
dte6StatusRTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RTS loss"
::= { dte6StatusEntry 15 }
dte6StatusEXTCLKloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 EXT-CLK loss"
::= { dte6StatusEntry 16 }
dte6StatusDSRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DSR"
::= { dte6StatusEntry 17 }
dte6StatusCTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 CTS"
::= { dte6StatusEntry 18 }
dte6StatusDCDstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DCD"
::= { dte6StatusEntry 19 }
dte6StatusDTRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DTR"
::= { dte6StatusEntry 20 }
dte6StatusRTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RTS"
::= { dte6StatusEntry 21 }
dte6StatusRemoteAlarm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Rdmote_X"
::= { dte6StatusEntry 22 }
dte6StatusFrameSync OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Local Sync"
::= { dte6StatusEntry 23 }
dte6StatusRemoteS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S1"
::= { dte6StatusEntry 24 }
dte6StatusRemoteS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S3"
::= { dte6StatusEntry 25 }
dte6StatusRemoteS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S4"
::= { dte6StatusEntry 26 }
dte6StatusRemoteS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S6"
::= { dte6StatusEntry 27 }
dte6StatusRemoteS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S8"
::= { dte6StatusEntry 28 }
dte6StatusRemoteS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit S9"
::= { dte6StatusEntry 29 }
dte6StatusRemoteE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit E4"
::= { dte6StatusEntry 30}
dte6StatusRemoteE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit E5"
::= { dte6StatusEntry 31 }
dte6StatusRemoteE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit E6"
::= { dte6StatusEntry 32 }
dte6StatusRemoteX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 remote status bit X"
::= { dte6StatusEntry 33 }
--
-- Alarm Control Table
--
dte6AlarmControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 alarm control table."
::= { dte6-card 4 }
dte6AlarmControlEntry OBJECT-TYPE
SYNTAX Dte6AlarmControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 alarm control table."
INDEX { dte6AlarmSlotIndex , dte6AlarmPortIndex }
::= { dte6AlarmControlTable 1 }
Dte6AlarmControlEntry ::= SEQUENCE {
dte6AlarmSlotIndex LargeSlotIndex,
dte6AlarmPortIndex SixPortID,
dte6AlarmSetup AlarmSeverity,
dte6AlarmM4LOLCSetup AlarmSeverity,
dte6AlarmM4LOCHSetup AlarmSeverity,
dte6AlarmM4CRESetup AlarmSeverity
}
dte6AlarmSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6AlarmControlEntry 1 }
dte6AlarmPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6AlarmControlEntry 2 }
dte6AlarmSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { dte6AlarmControlEntry 3 }
dte6AlarmM4LOLCSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm M4 LOLC is enabled or not"
::= { dte6AlarmControlEntry 4 }
dte6AlarmM4LOCHSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm M4 LOCH is enabled or not"
::= { dte6AlarmControlEntry 5 }
dte6AlarmM4CRESetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm M4 CRE is enabled or not"
::= { dte6AlarmControlEntry 6 }
--
-- Alarm History Table
--
dte6AlmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: dte6AlmHistoryUnitIndex "
::= { dte6-card 5 }
dte6AlmHistoryEntry OBJECT-TYPE
SYNTAX Dte6AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { dte6AlmHisSlotIndex , dte6AlmHisPortIndex }
::= { dte6AlmHistoryTable 1 }
Dte6AlmHistoryEntry ::= SEQUENCE {
dte6AlmHisSlotIndex LargeSlotIndex,
dte6AlmHisPortIndex SixPortID,
dte6AlmHistoryState INTEGER,
dte6AlmHistoryCount Counter,
dte6AlmHistoryEnable AlarmSeverity,
dte6AlmHisM4LOLCState INTEGER,
dte6AlmHisM4LOLCCount Counter,
dte6AlmHisM4LOLCEnable AlarmSeverity,
dte6AlmHisM4LOCHState INTEGER,
dte6AlmHisM4LOCHCount Counter,
dte6AlmHisM4LOCHEnable AlarmSeverity,
dte6AlmHisM4CREState INTEGER,
dte6AlmHisM4CRECount Counter,
dte6AlmHisM4CREEnable AlarmSeverity,
dte6AlmHisResetCount INTEGER
}
dte6AlmHisSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6AlmHistoryEntry 1 }
dte6AlmHisPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6AlmHistoryEntry 2 }
dte6AlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { dte6AlmHistoryEntry 3 }
dte6AlmHistoryCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { dte6AlmHistoryEntry 4 }
dte6AlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { dte6AlmHistoryEntry 5 }
dte6AlmHisM4LOLCState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 LOLC Current State"
::= { dte6AlmHistoryEntry 6 }
dte6AlmHisM4LOLCCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 LOLC Count which happened "
::= { dte6AlmHistoryEntry 7 }
dte6AlmHisM4LOLCEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm M4 LOLC is enabled or not"
::= { dte6AlmHistoryEntry 8 }
dte6AlmHisM4LOCHState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 LOCH Current State"
::= { dte6AlmHistoryEntry 9 }
dte6AlmHisM4LOCHCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 LOCH Count which happened "
::= { dte6AlmHistoryEntry 10 }
dte6AlmHisM4LOCHEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm M4 LOCH is enabled or not"
::= { dte6AlmHistoryEntry 11 }
dte6AlmHisM4CREState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 CRE Current State"
::= { dte6AlmHistoryEntry 12 }
dte6AlmHisM4CRECount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm M4 CRE Count which happened "
::= { dte6AlmHistoryEntry 13 }
dte6AlmHisM4CREEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm M4 CRE is enabled or not"
::= { dte6AlmHistoryEntry 14 }
dte6AlmHisResetCount OBJECT-TYPE
SYNTAX INTEGER {
no(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset alarm counter"
::= { dte6AlmHistoryEntry 15 }
--
-- Diagnostic Control Table
--
dte6DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { dte6-card 6 }
dte6DiagControlEntry OBJECT-TYPE
SYNTAX Dte6DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { dte6DiagCtrlSlotIndex , dte6DiagCtrlPortIndex }
::= { dte6DiagControlTable 1 }
Dte6DiagControlEntry ::= SEQUENCE {
dte6DiagCtrlSlotIndex LargeSlotIndex,
dte6DiagCtrlPortIndex SixPortID,
dte6NearLoopback INTEGER
}
dte6DiagCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6DiagControlEntry 1 }
dte6DiagCtrlPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6DiagControlEntry 2 }
dte6NearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
toDTE(2),
toLocal(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Loopback Type"
::= { dte6DiagControlEntry 3 }
--
-- DTE6 Card Control Table
--
dte6CardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Card control table."
::= { dte6-card 7 }
dte6CardControlEntry OBJECT-TYPE
SYNTAX Dte6CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 6UDTEA Card control table."
INDEX { dte6CardIndex }
::= { dte6CardControlTable 1 }
Dte6CardControlEntry ::= SEQUENCE {
dte6CardIndex LargeSlotIndex,
dte6Reset INTEGER,
dte6LoadDefault INTEGER
}
dte6CardIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6CardControlEntry 1 }
dte6Reset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset dte6 card"
::= { dte6CardControlEntry 2 }
dte6LoadDefault OBJECT-TYPE
SYNTAX INTEGER {
na(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { dte6CardControlEntry 3 }
--
-- DTE6 System Information Table
--
dte6SystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 system information table."
::= { dte6-card 8}
dte6SystemInfoEntry OBJECT-TYPE
SYNTAX Dte6SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 system information table."
INDEX { dte6SISlotIndex }
::= { dte6SystemInfoTable 1 }
Dte6SystemInfoEntry ::= SEQUENCE {
dte6SISlotIndex LargeSlotIndex,
dte6PROMVersion DisplayString,
dte6HardwareVersion DisplayString,
dte6FpgaVersion DisplayString,
dte6Bank1Version DisplayString,
dte6Bank2Version DisplayString,
dte6ActiveBank INTEGER,
dte6HardwareSupport INTEGER
}
dte6SISlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6SystemInfoEntry 1 }
dte6PROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE6 PROM Version"
::= { dte6SystemInfoEntry 2 }
dte6HardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" DTE6 Hardware Version"
::= { dte6SystemInfoEntry 3 }
dte6FpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { dte6SystemInfoEntry 4 }
dte6Bank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { dte6SystemInfoEntry 5 }
dte6Bank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { dte6SystemInfoEntry 6}
dte6ActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { dte6SystemInfoEntry 7 }
dte6HardwareSupport OBJECT-TYPE
SYNTAX INTEGER{
r1(1),
r2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Revision1 support m1 m2 m3 m4, Revision2 support m1 m2 m3 m4 m5"
::= { dte6SystemInfoEntry 8 }
--
-- DTE6 M2 Configuration
--
dte6M2ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M2ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Interface M2 Configuration table."
::= { dte6-card 9 }
dte6M2ConfigEntry OBJECT-TYPE
SYNTAX Dte6M2ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Configuration table."
INDEX { dte6M2CfgSlotIndex , dte6M2CfgPortIndex }
::= { dte6M2ConfigTable 1 }
Dte6M2ConfigEntry ::= SEQUENCE {
dte6M2CfgSlotIndex LargeSlotIndex,
dte6M2CfgPortIndex SixPortID,
dte6M2CfgInterface INTEGER,
dte6M2CfgChannel INTEGER,
dte6M2CfgDS0Rate INTEGER,
dte6M2CfgClockPolarity INTEGER,
dte6M2CfgDataPolarity INTEGER,
dte6M2CfgTTM INTEGER,
dte6M2CfgRTS INTEGER,
dte6M2CfgDTR INTEGER,
dte6M2CfgOversamplingRate INTEGER,
dte6M2CfgSupportDataRate DisplayString,
dte6M2CfgWarrning DisplayString,
dte6M2CfgV54 INTEGER
}
dte6M2CfgSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6M2ConfigEntry 1 }
dte6M2CfgPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6M2ConfigEntry 2 }
dte6M2CfgInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs422(2),
x21(3),
v35(4),
v36(5),
eia530Rs449(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Interface mode"
::= { dte6M2ConfigEntry 3 }
dte6M2CfgChannel OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Channel"
::= { dte6M2ConfigEntry 4 }
dte6M2CfgDS0Rate OBJECT-TYPE
SYNTAX INTEGER {
r64K(1),
r56K(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 DS0 Rate"
::= { dte6M2ConfigEntry 5 }
dte6M2CfgClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Clock Polarity"
::= { dte6M2ConfigEntry 6 }
dte6M2CfgDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Data Polarity"
::= { dte6M2ConfigEntry 7 }
dte6M2CfgTTM OBJECT-TYPE
SYNTAX INTEGER {
ttmOff(1),
ttmOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 TTM Mode"
::= { dte6M2ConfigEntry 8 }
dte6M2CfgRTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 RTS Mode"
::= { dte6M2ConfigEntry 9 }
dte6M2CfgDTR OBJECT-TYPE
SYNTAX INTEGER {
dtrActive(1),
dtrPermanent(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 DTR Mode"
::= { dte6M2ConfigEntry 10 }
dte6M2CfgOversamplingRate OBJECT-TYPE
SYNTAX INTEGER (0..384)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Oversampling Rate"
::= { dte6M2ConfigEntry 11 }
dte6M2CfgSupportDataRate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..160) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Support Data Rate"
::= { dte6M2ConfigEntry 12 }
dte6M2CfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Warrning"
::= { dte6M2ConfigEntry 13 }
dte6M2CfgV54 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
ansi(2),
itu(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 V.54 Setup"
::= { dte6M2ConfigEntry 14 }
--
-- DTE6 M2 Status
--
dte6M2StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M2StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 M2Status table."
::= { dte6-card 10}
dte6M2StatusEntry OBJECT-TYPE
SYNTAX Dte6M2StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Status table."
INDEX { dte6M2StatusSlotIndex , dte6M2StatusPortIndex }
::= { dte6M2StatusTable 1 }
Dte6M2StatusEntry ::= SEQUENCE {
dte6M2StatusSlotIndex LargeSlotIndex,
dte6M2StatusPortIndex SixPortID,
dte6M2StatusDteDCD INTEGER,
dte6M2StatusRTSloss INTEGER,
dte6M2StatusEXTCLKloss INTEGER,
dte6M2StatusDSRstatus INTEGER,
dte6M2StatusCTSstatus INTEGER,
dte6M2StatusDCDstatus INTEGER,
dte6M2StatusDTRstatus INTEGER,
dte6M2StatusRTSstatus INTEGER,
dte6M2StatusRxBytesCounter INTEGER,
dte6M2StatusTxBytesCounter INTEGER
}
dte6M2StatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6M2StatusEntry 1 }
dte6M2StatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6M2StatusEntry 2 }
dte6M2StatusDteDCD OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Status bit DTE DCD"
::= { dte6M2StatusEntry 3 }
dte6M2StatusRTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RTS loss"
::= { dte6M2StatusEntry 4 }
dte6M2StatusEXTCLKloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 EXT-CLK loss"
::= { dte6M2StatusEntry 5 }
dte6M2StatusDSRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DSR"
::= { dte6M2StatusEntry 6 }
dte6M2StatusCTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 CTS"
::= { dte6M2StatusEntry 7 }
dte6M2StatusDCDstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DCD"
::= { dte6M2StatusEntry 8 }
dte6M2StatusDTRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 DTR"
::= { dte6M2StatusEntry 9 }
dte6M2StatusRTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RTS"
::= { dte6M2StatusEntry 10 }
dte6M2StatusRxBytesCounter OBJECT-TYPE
SYNTAX INTEGER (0..131071)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RxBytesCounter"
::= { dte6M2StatusEntry 11 }
dte6M2StatusTxBytesCounter OBJECT-TYPE
SYNTAX INTEGER (0..131071)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 TxBytesCounter"
::= { dte6M2StatusEntry 12 }
--
-- DTE6 M2 Diagnostic Control Table
--
dte6M2DiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M2DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 M2 Diagnostic Control Table."
::= { dte6-card 11 }
dte6M2DiagControlEntry OBJECT-TYPE
SYNTAX Dte6M2DiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 diagnostic control table."
INDEX { dte6M2DiagCtrlSlotIndex , dte6M2DiagCtrlPortIndex }
::= { dte6M2DiagControlTable 1 }
Dte6M2DiagControlEntry ::= SEQUENCE {
dte6M2DiagCtrlSlotIndex LargeSlotIndex,
dte6M2DiagCtrlPortIndex SixPortID,
dte6M2DiagCtrlloopbacktype INTEGER,
dte6M2DiagCtrlloopbackstatus INTEGER,
dte6M2DiagCtrlbertctrl INTEGER,
dte6M2DiagCtrlbertstatus INTEGER,
dte6M2DiagCtrlelapseseconds INTEGER,
dte6M2DiagCtrlerrorseconds INTEGER,
dte6M2DiagCtrlerrorcounts INTEGER
}
dte6M2DiagCtrlSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6M2DiagControlEntry 1 }
dte6M2DiagCtrlPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { dte6M2DiagControlEntry 2 }
dte6M2DiagCtrlloopbacktype OBJECT-TYPE
SYNTAX INTEGER {
noloopback(1),
loopbackToDTE(2),
loopbackToLine(3),
remoteV54active(4),
remoteV54deactive(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M2 Loopback Type"
::= { dte6M2DiagControlEntry 3 }
dte6M2DiagCtrlloopbackstatus OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2),
loopbacknotactive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 M2 Loopback Status"
::= { dte6M2DiagControlEntry 4 }
dte6M2DiagCtrlbertctrl OBJECT-TYPE
SYNTAX INTEGER {
bertDEACTIVE(1),
bertACTIVEDTE(2),
bertRESETERRORCOUNT(3),
bertINJECTERROR(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M2 PRBS/QRSS Control"
::= { dte6M2DiagControlEntry 5 }
dte6M2DiagCtrlbertstatus OBJECT-TYPE
SYNTAX INTEGER {
bertSYNC(1),
bertUNSYNC(2),
bertNOTACTIVE(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 M2 PRBS/QRSS Status"
::= { dte6M2DiagControlEntry 6 }
dte6M2DiagCtrlelapseseconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte6 M2 PRBS/QRSS Elapse Seconds"
::= { dte6M2DiagControlEntry 7 }
dte6M2DiagCtrlerrorseconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte6 M2 PRBS/QRSS Error Seconds"
::= { dte6M2DiagControlEntry 8 }
dte6M2DiagCtrlerrorcounts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"dte6 M2 PRBS/QRSS Error Counts"
::= { dte6M2DiagControlEntry 9 }
-- DTE6 M4 Config
dte6M4ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M4ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Interface M4 Configuration table."
::= { dte6-card 12}
dte6M4ConfigEntry OBJECT-TYPE
SYNTAX Dte6M4ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Configuration table."
INDEX { dte6M4CfgSlotIndex, dte6M4CfgPortIndex }
::= { dte6M4ConfigTable 1 }
Dte6M4ConfigEntry ::= SEQUENCE {
dte6M4CfgSlotIndex LargeSlotIndex,
dte6M4CfgPortIndex SixPortID,
dte6M4CfgInterface INTEGER,
dte6M4CfgBaudRate INTEGER,
dte6M4CfgClkInInverse INTEGER,
dte6M4CfgClkOutInverse INTEGER,
dte6M4CfgPCMDataInverse INTEGER,
dte6M4CfgWarrning DisplayString
}
dte6M4CfgSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 M4 slot index"
::= { dte6M4ConfigEntry 1 }
dte6M4CfgPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, Total 4 ports"
::= { dte6M4ConfigEntry 2 }
dte6M4CfgInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs422(2),
x21(3),
v35(4),
v36(5),
eia530Rs449(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M4 Interface mode"
::= { dte6M4ConfigEntry 3 }
dte6M4CfgBaudRate OBJECT-TYPE
SYNTAX INTEGER (1..38400)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M4 baud rate"
::= { dte6M4ConfigEntry 4 }
dte6M4CfgClkInInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M4 clock input inverse"
::= { dte6M4ConfigEntry 5 }
dte6M4CfgClkOutInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M4 clock output inverse"
::= { dte6M4ConfigEntry 6 }
dte6M4CfgPCMDataInverse OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 M4 PCM data inverse"
::= { dte6M4ConfigEntry 7 }
dte6M4CfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Warrning"
::= { dte6M4ConfigEntry 8 }
-- DTE6 M4 Status
dte6M4StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M4StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 M4Status table."
::= { dte6-card 13}
dte6M4StatusEntry OBJECT-TYPE
SYNTAX Dte6M4StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Status table."
INDEX { dte6M4StatusSlotIndex,dte6M4StatusPortIndex }
::= { dte6M4StatusTable 1 }
Dte6M4StatusEntry ::= SEQUENCE {
dte6M4StatusSlotIndex LargeSlotIndex,
dte6M4StatusPortIndex SixPortID,
dte6M4StatusLOLC INTEGER,
dte6M4StatusLOCH INTEGER,
dte6M4StatusCRE INTEGER,
dte6M4StatusRxBytesCnt INTEGER,
dte6M4StatusTxBytesCnt INTEGER
}
dte6M4StatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6M4StatusEntry 1 }
dte6M4StatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, Total 4 ports"
::= { dte6M4StatusEntry 2 }
dte6M4StatusLOLC OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Loss Of Clock status "
::= { dte6M4StatusEntry 3 }
dte6M4StatusLOCH OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Loss Of Channel status "
::= { dte6M4StatusEntry 4 }
dte6M4StatusCRE OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Clock Recovery Error status "
::= { dte6M4StatusEntry 5 }
dte6M4StatusRxBytesCnt OBJECT-TYPE
SYNTAX INTEGER (0..131071)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 RxBytesCounter"
::= { dte6M4StatusEntry 6 }
dte6M4StatusTxBytesCnt OBJECT-TYPE
SYNTAX INTEGER (0..131071)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 TxBytesCounter"
::= { dte6M4StatusEntry 7 }
-- DTE6 M5 Configuration
dte6M5ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dte6M5ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DTE6 Interface M5 Configuration table."
::= { dte6-card 14 }
dte6M5ConfigEntry OBJECT-TYPE
SYNTAX Dte6M5ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the DTE6 Configuration table."
INDEX { dte6M5CfgSlotIndex, dte6M5CfgPortIndex }
::= { dte6M5ConfigTable 1 }
Dte6M5ConfigEntry ::= SEQUENCE {
dte6M5CfgSlotIndex LargeSlotIndex,
dte6M5CfgPortIndex SixPortID,
dte6M5CfgInterface INTEGER,
dte6M5CfgChannel INTEGER,
dte6M5CfgDS0Rate INTEGER,
dte6M5CfgClockPolarity INTEGER,
dte6M5CfgDataPolarity INTEGER,
dte6M5CfgRTS INTEGER,
dte6M5CfgV54 INTEGER,
dte6M5CfgV54RL INTEGER,
dte6M5CfgV54LL INTEGER,
dte6M5CfgWarrning DisplayString
}
dte6M5CfgSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 slot index"
::= { dte6M5ConfigEntry 1 }
dte6M5CfgPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 4, Total 4 ports"
::= { dte6M5ConfigEntry 2 }
dte6M5CfgInterface OBJECT-TYPE
SYNTAX INTEGER {
rs232(1),
rs422(2),
x21(3),
v35(4),
v36(5),
eia530Rs449(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Interface mode"
::= { dte6M5ConfigEntry 3 }
dte6M5CfgChannel OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Channel"
::= { dte6M5ConfigEntry 4 }
dte6M5CfgDS0Rate OBJECT-TYPE
SYNTAX INTEGER {
r64K(1),
r56K(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 DS0 Rate"
::= { dte6M5ConfigEntry 5 }
dte6M5CfgClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Clock Polarity"
::= { dte6M5ConfigEntry 6 }
dte6M5CfgDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 Data Polarity"
::= { dte6M5ConfigEntry 7 }
dte6M5CfgRTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 RTS Mode"
::= { dte6M5ConfigEntry 8 }
dte6M5CfgV54 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
ansi(2),
itu(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 V54 Setup"
::= { dte6M5ConfigEntry 9 }
dte6M5CfgV54RL OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 V54 RL Setup"
::= { dte6M5ConfigEntry 10 }
dte6M5CfgV54LL OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DTE6 V54 LL Setup"
::= { dte6M5ConfigEntry 11 }
dte6M5CfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DTE6 Warrning"
::= { dte6M5ConfigEntry 12 }
--
dte6TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of DTE6"
::= { dte6-card 100 }
--======================================================================--
--======================================================================--
-- 6CDA Card MIB
--======================================================================--
--======================================================================--
--
--Config Table
--
cda6ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Config Table "
::= { cda6-card 1 }
cda6ConfigEntry OBJECT-TYPE
SYNTAX Cda6ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Config Table "
INDEX { cda6ConfigSlotIndex , cda6ConfigPortIndex }
::= { cda6ConfigTable 1 }
Cda6ConfigEntry ::= SEQUENCE {
cda6ConfigSlotIndex LargeSlotIndex,
cda6ConfigPortIndex SixPortID,
cda6ConfigInterface INTEGER,
cda6ConfigType INTEGER,
cda6ConfigOctetClock INTEGER,
cda6ConfigTxClock INTEGER
}
cda6ConfigSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6ConfigEntry 1 }
cda6ConfigPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports "
::= { cda6ConfigEntry 2 }
cda6ConfigInterface OBJECT-TYPE
SYNTAX INTEGER {
contradirectional(1),
codirectional(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Interface "
::= { cda6ConfigEntry 3 }
cda6ConfigType OBJECT-TYPE
SYNTAX INTEGER {
subordinate(1),
controlling(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Type "
::= { cda6ConfigEntry 4 }
cda6ConfigOctetClock OBJECT-TYPE
SYNTAX INTEGER {
fromControl(1),
fromSub(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Octet Clock "
::= { cda6ConfigEntry 5 }
cda6ConfigTxClock OBJECT-TYPE
SYNTAX INTEGER {
rxPin(1),
txPin(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Tx Clock "
::= { cda6ConfigEntry 6 }
--
-- Loopback Test Table
--
cda6LpbackTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6LpbackTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Loopback Test Table "
::= { cda6-card 2 }
cda6LpbackTestEntry OBJECT-TYPE
SYNTAX Cda6LpbackTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Loopback Test Table "
INDEX { cda6SlotIndex , cda6PortIndex }
::= { cda6LpbackTestTable 1 }
Cda6LpbackTestEntry ::= SEQUENCE {
cda6SlotIndex LargeSlotIndex,
cda6PortIndex SixPortID,
cda6NearEndLoopback INTEGER,
cda6SendTestPattern INTEGER,
cda6Bert INTEGER,
cda6BitError INTEGER,
cda6ErrorSeconds INTEGER,
cda6ElapsedSeconds INTEGER
}
cda6SlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6LpbackTestEntry 1 }
cda6PortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports "
::= { cda6LpbackTestEntry 2 }
cda6NearEndLoopback OBJECT-TYPE
SYNTAX INTEGER {
off(1),
local(2),
line(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" NEAR-END LOOPBACK "
::= { cda6LpbackTestEntry 3 }
cda6SendTestPattern OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
reset(3),
injectError(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Send Test Pattern "
::= { cda6LpbackTestEntry 4 }
cda6Bert OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
unsync(2),
notActive(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BERT "
::= { cda6LpbackTestEntry 5 }
cda6BitError OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" BIT ERROR "
::= { cda6LpbackTestEntry 6 }
cda6ErrorSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ERROR SECONDS "
::= { cda6LpbackTestEntry 7 }
cda6ElapsedSeconds OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" ELAPSED SECONDS "
::= { cda6LpbackTestEntry 8 }
--
-- Status Table
--
cda6StatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The Status Table "
::= { cda6-card 3 }
cda6StatusEntry OBJECT-TYPE
SYNTAX Cda6StatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Status Table "
INDEX { cda6StatusSlotIndex , cda6StatusPortIndex }
::= { cda6StatusTable 1 }
Cda6StatusEntry ::= SEQUENCE {
cda6StatusSlotIndex LargeSlotIndex,
cda6StatusPortIndex SixPortID,
cda6StatusLos INTEGER,
cda6StatusLoo INTEGER,
cda6StatusLocalLpback INTEGER,
cda6StatusLineLpback INTEGER
}
cda6StatusSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6StatusEntry 1 }
cda6StatusPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports "
::= { cda6StatusEntry 2 }
cda6StatusLos OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LINE - LOS "
::= { cda6StatusEntry 3 }
cda6StatusLoo OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" LINE - LOO "
::= { cda6StatusEntry 4 }
cda6StatusLocalLpback OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TEST - LOCAL LOOPBACK "
::= { cda6StatusEntry 5 }
cda6StatusLineLpback OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" TEST - Line LOOPBACK "
::= { cda6StatusEntry 6 }
--
-- Alarm Setup Table
--
cda6AlarmSetupTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6AlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm Setup Table "
::= { cda6-card 4 }
cda6AlarmSetupEntry OBJECT-TYPE
SYNTAX Cda6AlarmSetupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Alarm Setup Table "
INDEX { cda6AlmStpSlotIndex , cda6AlmStpPortIndex , cda6AlmStpTypeIndex }
::= { cda6AlarmSetupTable 1 }
Cda6AlarmSetupEntry ::= SEQUENCE {
cda6AlmStpSlotIndex LargeSlotIndex,
cda6AlmStpPortIndex SixPortID,
cda6AlmStpTypeIndex INTEGER,
cda6AlmStpAlarm INTEGER
}
cda6AlmStpSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6AlarmSetupEntry 1 }
cda6AlmStpPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports "
::= { cda6AlarmSetupEntry 2 }
cda6AlmStpTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
los(1),
loo(2),
txClkLoss(3),
rxClkLoss(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Type "
::= { cda6AlarmSetupEntry 3 }
cda6AlmStpAlarm OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
major(2),
critical(3),
minor(4),
na(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm "
::= { cda6AlarmSetupEntry 4 }
--
-- Alarm History Table
--
cda6AlmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Alarm History Table "
::= { cda6-card 5 }
cda6AlmHistoryEntry OBJECT-TYPE
SYNTAX Cda6AlmHistoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the Alarm History Table "
INDEX { cda6AlmHistorySlotIndex , cda6AlmHistoryPortIndex , cda6AlmHistoryTypeIndex }
::= { cda6AlmHistoryTable 1 }
Cda6AlmHistoryEntry ::= SEQUENCE {
cda6AlmHistorySlotIndex LargeSlotIndex,
cda6AlmHistoryPortIndex SixPortID,
cda6AlmHistoryTypeIndex INTEGER,
cda6AlmHistoryState INTEGER,
cda6AlmHistoryCount INTEGER,
cda6AlmHistoryAlarm INTEGER
}
cda6AlmHistorySlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6AlmHistoryEntry 1 }
cda6AlmHistoryPortIndex OBJECT-TYPE
SYNTAX SixPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Port 1 to 6, Total 6 ports "
::= { cda6AlmHistoryEntry 2 }
cda6AlmHistoryTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
los(1),
loo(2),
txClkLoss(3),
rxClkLoss(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Type "
::= { cda6AlmHistoryEntry 3 }
cda6AlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" State "
::= { cda6AlmHistoryEntry 4 }
cda6AlmHistoryCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Count "
::= { cda6AlmHistoryEntry 5 }
cda6AlmHistoryAlarm OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
major(2),
critical(3),
minor(4),
na(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm "
::= { cda6AlmHistoryEntry 6 }
--
-- Card Control Table
--
cda6CardControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The CDA6 Card Control Table "
::= { cda6-card 6 }
cda6CardControlEntry OBJECT-TYPE
SYNTAX Cda6CardControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the CDA6 Card Control Table "
INDEX { cda6CardIndex }
::= { cda6CardControlTable 1 }
Cda6CardControlEntry ::= SEQUENCE {
cda6CardIndex LargeSlotIndex,
cda6Reset INTEGER,
cda6LoadDefault INTEGER,
cda6AlarmReset INTEGER
}
cda6CardIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6CardControlEntry 1 }
cda6Reset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Reset CDA6 card "
::= { cda6CardControlEntry 2 }
cda6LoadDefault OBJECT-TYPE
SYNTAX INTEGER {
na(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Load default "
::= { cda6CardControlEntry 3 }
cda6AlarmReset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Alarm Counr Reset "
::= { cda6CardControlEntry 4 }
--
-- CDA6 System Information Table
--
cda6SystemInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Cda6SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" The CDA6 System Information Table "
::= { cda6-card 7 }
cda6SystemInfoEntry OBJECT-TYPE
SYNTAX Cda6SystemInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" An entry in the CDA6 System Information Table "
INDEX { cda6SystemInfoSlotIndex }
::= { cda6SystemInfoTable 1 }
Cda6SystemInfoEntry ::= SEQUENCE {
cda6SystemInfoSlotIndex LargeSlotIndex,
cda6SystemInfoPROMVersion DisplayString,
cda6SystemInfoHardwareVersion DisplayString,
cda6SystemInfoFpgaVersion DisplayString,
cda6SystemInfoBank1Version DisplayString,
cda6SystemInfoBank2Version DisplayString,
cda6SystemInfoActiveBank INTEGER
}
cda6SystemInfoSlotIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { cda6SystemInfoEntry 1 }
cda6SystemInfoPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CDA6 PROM Version "
::= { cda6SystemInfoEntry 2 }
cda6SystemInfoHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" CDA6 Hardware Version "
::= { cda6SystemInfoEntry 3 }
cda6SystemInfoFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" FPGA Version "
::= { cda6SystemInfoEntry 4 }
cda6SystemInfoBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bank-1 Version "
::= { cda6SystemInfoEntry 5 }
cda6SystemInfoBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Bank-2 Version "
::= { cda6SystemInfoEntry 6}
cda6SystemInfoActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Active Bank 1/2 "
::= { cda6SystemInfoEntry 7 }
cda6TotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total cards of CDA6 "
::= { cda6-card 100 }
--======================================================================--
--======================================================================--
-- QMAG Card MIB
--======================================================================--
--======================================================================--
--
-- QMAG All Port Config Control Table
--
qmagAllPortSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QMagAllPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG All Port Configuration Control Table"
::= { qmag-card 1 }
qmagAllPortSetEntry OBJECT-TYPE
SYNTAX QMagAllPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG all port configuration control entry"
INDEX { qmagAllPortSetIndex }
::= { qmagAllPortSetTable 1 }
QMagAllPortSetEntry ::= SEQUENCE {
qmagAllPortSetIndex SmallSlotIndex,
qmagAllPortSetAuLaw INTEGER,
qmagAllPortSetImpedance INTEGER
}
qmagAllPortSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagAllPortSetEntry 1 }
qmagAllPortSetAuLaw OBJECT-TYPE
SYNTAX INTEGER {
u-law(1),
a-law(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" A/u LAW "
::= { qmagAllPortSetEntry 2 }
qmagAllPortSetImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp-900-ohm(1),
imp-600-ohm(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" IMPEDANCE "
::= { qmagAllPortSetEntry 3 }
--
-- QMAG All Port Signaling Config Control Table
--
qmagSigSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QMagSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG All Port Signaling Configuration Control Table"
::= { qmag-card 2 }
qmagSigSetEntry OBJECT-TYPE
SYNTAX QMagSigSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG all port signaling configuration control entry"
INDEX { qmagSigSetIndex ,
qmagSigSetItemIndex ,
qmagSigSetSigBitIndex }
::= { qmagSigSetTable 1 }
QMagSigSetEntry ::= SEQUENCE {
qmagSigSetIndex SmallSlotIndex,
qmagSigSetItemIndex INTEGER,
qmagSigSetSigBitIndex INTEGER,
qmagSigSetSigBit INTEGER
}
qmagSigSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagSigSetEntry 1 }
qmagSigSetItemIndex OBJECT-TYPE
SYNTAX INTEGER {
crankStop(1),
crankStart(2),
crankStartPLAR(3),
noRing(4),
ringing(5),
plarRinging(6),
oosAlarm(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"QMAG signaling setup "
::= { qmagSigSetEntry 2 }
qmagSigSetSigBitIndex OBJECT-TYPE
SYNTAX INTEGER {
a(1),
b(2),
c(3),
d(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Signaling Bit Index "
::= { qmagSigSetEntry 3 }
qmagSigSetSigBit OBJECT-TYPE
SYNTAX INTEGER {
zero(0),
one(1),
do-not-care(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Signaling Bit Setup 0/1 or don't care "
::= { qmagSigSetEntry 4 }
--
-- Qmag Per Port Config Control Table
--
qmagPortSetTable OBJECT-TYPE
SYNTAX SEQUENCE OF QMagPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG Per Port Configuration Control Table"
::= { qmag-card 3 }
qmagPortSetEntry OBJECT-TYPE
SYNTAX QMagPortSetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG Per Port Configuration control entry"
INDEX { qmagPortSetIndex ,
qmagPortSetPortIndex }
::= { qmagPortSetTable 1 }
QMagPortSetEntry ::= SEQUENCE {
qmagPortSetIndex SmallSlotIndex,
qmagPortSetPortIndex FourPortID,
qmagPortSetTxGain DisplayString,
qmagPortSetRxGain DisplayString,
qmagPortSetPLAR INTEGER,
qmagPortStopWatch INTEGER,
qmagPortPLARStopWatch INTEGER,
qmagPortSetRingerLine INTEGER
}
qmagPortSetIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagPortSetEntry 1 }
qmagPortSetPortIndex OBJECT-TYPE
SYNTAX FourPortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { qmagPortSetEntry 2 }
qmagPortSetTxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port TX-GAIN setting "
::= { qmagPortSetEntry 3 }
qmagPortSetRxGain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port RX-GAIN setting "
::= { qmagPortSetEntry 4 }
qmagPortSetPLAR OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Per port PLAR setting "
::= { qmagPortSetEntry 5 }
qmagPortStopWatch OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" StopWatch N/A, 0.7s, 1.0s, 1.5s, 2.0s "
::= { qmagPortSetEntry 6 }
qmagPortPLARStopWatch OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" StopWatch Plar N/A, 0.7s, 1.0s, 1.5s, 2.0s "
::= { qmagPortSetEntry 7 }
qmagPortSetRingerLine OBJECT-TYPE
SYNTAX INTEGER {
l1-l2(1),
l1-gnd(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Ringer Across Line "
::= { qmagPortSetEntry 8 }
--
-- QMAG Command Control Table
--
qmagCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QMagCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { qmag-card 4 }
qmagCommandControlEntry OBJECT-TYPE
SYNTAX QMagCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { qmagCommandControlIndex }
::= { qmagCommandControlTable 1 }
QMagCommandControlEntry ::= SEQUENCE {
qmagCommandControlIndex SmallSlotIndex,
qmagCommandControlReset INTEGER,
qmagCommandControlLoadDefault INTEGER
}
qmagCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagCommandControlEntry 1 }
qmagCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default MAG CONF"
::= { qmagCommandControlEntry 2 }
qmagCommandControlReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: MAG Card Reset"
::= { qmagCommandControlEntry 3 }
--
-- QMAG Per Port Diag InfoTable
--
qmagDiagInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF QmagDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG Diag Info Table"
::= { qmag-card 5 }
qmagDiagInfoEntry OBJECT-TYPE
SYNTAX QmagDiagInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG Diag Infoentry"
INDEX { qmagDiagInfoIndex ,
qmagDiagInfoPort }
::= { qmagDiagInfoTable 1 }
QmagDiagInfoEntry ::= SEQUENCE {
qmagDiagInfoIndex SmallSlotIndex,
qmagDiagInfoPort TwelvePortID,
qmagDiagInfoAuLaw INTEGER,
qmagDiagInfoIMP INTEGER,
qmagDiagInfoCrank EMOffOn,
qmagDiagInfoRingSig EMOffOn,
qmagDiagInfoAIS EMOffOn,
qmagDiagInfoOOS EMOffOn,
qmagDiagInfoRingerLine INTEGER,
qmagDiagInfoRingDuration INTEGER,
qmagDiagInfoPlar INTEGER,
qmagDiagInfoInputPW INTEGER,
qmagDiagInfoPWStatus INTEGER,
qmagDiagInfoRingerGen INTEGER,
qmagDiagInfoRingerStatus INTEGER,
qmagDiagInfoTx DisplayString,
qmagDiagInfoRx DisplayString
}
qmagDiagInfoIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagDiagInfoEntry 1 }
qmagDiagInfoPort OBJECT-TYPE
SYNTAX TwelvePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"port 1-12"
::= { qmagDiagInfoEntry 2 }
qmagDiagInfoAuLaw OBJECT-TYPE
SYNTAX INTEGER {
aLaw(1),
uLaw(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" A u Law"
::= { qmagDiagInfoEntry 3}
qmagDiagInfoIMP OBJECT-TYPE
SYNTAX INTEGER {
imp900(1),
imp600(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Impedance"
::= { qmagDiagInfoEntry 4}
qmagDiagInfoCrank OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Crank "
::= { qmagDiagInfoEntry 5}
qmagDiagInfoRingSig OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Ring Signal "
::= { qmagDiagInfoEntry 6}
qmagDiagInfoAIS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" AIS alarm"
::= { qmagDiagInfoEntry 7}
qmagDiagInfoOOS OBJECT-TYPE
SYNTAX EMOffOn
ACCESS read-only
STATUS mandatory
DESCRIPTION
" OOS alarm "
::= { qmagDiagInfoEntry 8}
qmagDiagInfoRingerLine OBJECT-TYPE
SYNTAX INTEGER {
l1-l2(1),
l1-gnd(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { qmagDiagInfoEntry 9}
qmagDiagInfoRingDuration OBJECT-TYPE
SYNTAX INTEGER {
na(1),
sec-0-7(2),
sec-1-0(3),
sec-1-5(4),
sec-2-0(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Ring Duration"
::= { qmagDiagInfoEntry 10}
qmagDiagInfoPlar OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" PLAR "
::= { qmagDiagInfoEntry 11}
qmagDiagInfoInputPW OBJECT-TYPE
SYNTAX INTEGER {
plusMinus48v(1),
plusMinus24v(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" INPUT POWER"
::= { qmagDiagInfoEntry 12}
qmagDiagInfoPWStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { qmagDiagInfoEntry 13}
qmagDiagInfoRingerGen OBJECT-TYPE
SYNTAX INTEGER {
vac-76-and-16-7Hz(1),
vac-76-and-20-0Hz(2),
vac-76-and-50-0Hz(3),
vac-76-and-25-0Hz(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" RingerGen"
::= { qmagDiagInfoEntry 14}
qmagDiagInfoRingerStatus OBJECT-TYPE
SYNTAX INTEGER {
fail(1),
ok(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Side L1~L4 "
::= { qmagDiagInfoEntry 15}
qmagDiagInfoTx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port TX-signal "
::= { qmagDiagInfoEntry 16 }
qmagDiagInfoRx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Per port RX-signal"
::= { qmagDiagInfoEntry 17}
--
-- QMAG Line Diagnostic Control Table
--
qmagDiagControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF QmagDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"QMAG Diagnostic Control Table."
::= { qmag-card 6 }
qmagDiagControlEntry OBJECT-TYPE
SYNTAX QmagDiagControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry of QMAG diagnostic control table."
INDEX { qmagDiagControlSlot }
::= { qmagDiagControlTable 1 }
QmagDiagControlEntry ::= SEQUENCE {
qmagDiagControlSlot SmallSlotIndex,
qmagDiagControlTest INTEGER,
qmagDiagControlRemain INTEGER
}
qmagDiagControlSlot OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { qmagDiagControlEntry 1 }
qmagDiagControlTest OBJECT-TYPE
SYNTAX INTEGER {
stop(1),
crank-test(2),
ring-test(3),
channel-swap(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"QMAG Test Button"
::= { qmagDiagControlEntry 2 }
qmagDiagControlRemain OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"remain time"
::= { qmagDiagControlEntry 3 }
qmagTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total cards of QMAG "
::= { qmag-card 100 }
--======================================================================--
--======================================================================--
-- VoIP Card MIB
--======================================================================--
--======================================================================--
--
-- VoIP WAN Setup Table
--
voipWanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipWanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP WAN Setup Table"
::= { voip-card 1 }
voipWanEntry OBJECT-TYPE
SYNTAX VoipWanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP WAN Setup entry"
INDEX { voipWanIndex }
::= { voipWanTable 1 }
VoipWanEntry ::= SEQUENCE {
voipWanIndex LargeSlotIndex,
voipWanType INTEGER,
voipWanMTU INTEGER,
voipWanDNS INTEGER,
voipWanPriDNS IpAddress,
voipWanSecDNS IpAddress,
voipWanDHCPHost DisplayString,
voipWanDHCPVendor DisplayString,
voipWanStaticIP IpAddress,
voipWanStaticSubnet IpAddress,
voipWanStaticGW IpAddress,
voipWanPPPoEAccount DisplayString,
voipWanPPPoEPW DisplayString,
voipWanPPPoEServer DisplayString,
voipWanPPPoEReConnect INTEGER,
voipWanPPPoEMaxIdle INTEGER
}
voipWanIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipWanEntry 1 }
voipWanType OBJECT-TYPE
SYNTAX INTEGER {
dhcp(1),
staticIP(2),
pppoe(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" WAN Type "
::= { voipWanEntry 2 }
voipWanMTU OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MTU "
::= { voipWanEntry 3 }
voipWanDNS OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server "
::= { voipWanEntry 4 }
voipWanPriDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server ( Primary ) IP"
::= { voipWanEntry 5 }
voipWanSecDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server ( Secondary ) IP"
::= { voipWanEntry 6 }
voipWanDHCPHost OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DHCP hostname "
::= { voipWanEntry 7 }
voipWanDHCPVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" DHCP Vendor Class ID "
::= { voipWanEntry 8 }
voipWanStaticIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Static IP address "
::= { voipWanEntry 9 }
voipWanStaticSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Static IP Subnet "
::= { voipWanEntry 10 }
voipWanStaticGW OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Static IP Gateway "
::= { voipWanEntry 11 }
voipWanPPPoEAccount OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PPPoE Account "
::= { voipWanEntry 12 }
voipWanPPPoEPW OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PPPoE Password "
::= { voipWanEntry 13 }
voipWanPPPoEServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PPPoE Server name "
::= { voipWanEntry 14 }
voipWanPPPoEReConnect OBJECT-TYPE
SYNTAX INTEGER {
na(0), --//RIKER2021 SilverCreek
alwaysOn(1),
onDemand(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PPPoE Reconnect Mode "
::= { voipWanEntry 15 }
voipWanPPPoEMaxIdle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
" PPPoE Max Idle time "
::= { voipWanEntry 16 }
--
-- VoIP LAN Setup Table
--
voipLanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipLanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP LAN Setup Table"
::= { voip-card 2 }
voipLanEntry OBJECT-TYPE
SYNTAX VoipLanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP LAN Setup entry"
INDEX { voipLanIndex }
::= { voipLanTable 1 }
VoipLanEntry ::= SEQUENCE {
voipLanIndex LargeSlotIndex,
voipLanGateWay IpAddress,
voipLanSubnet IpAddress,
voipLanDHCP INTEGER,
voipLanStartIP IpAddress,
voipLanEndIP IpAddress,
voipLanGWEnable INTEGER,
voipLanDefaultGW IpAddress,
voipLanDefaultSubnet IpAddress,
voipLanLeaseTime INTEGER,
voipLanDNS INTEGER,
voipLanPriDNS IpAddress,
voipLanSecDNS IpAddress
}
voipLanIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipLanEntry 1 }
voipLanGateWay OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"LAN IP / LAN default Gateway"
::= { voipLanEntry 2 }
voipLanSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask "
::= { voipLanEntry 3 }
voipLanDHCP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"enable DHCP server "
::= { voipLanEntry 4 }
voipLanStartIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Pool Starting Address "
::= { voipLanEntry 5 }
voipLanEndIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Pool Ending Address "
::= { voipLanEntry 6 }
voipLanGWEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Pool Uses Other Default Gw"
::= { voipLanEntry 7 }
voipLanDefaultGW OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Pool Default Gateway "
::= { voipLanEntry 8 }
voipLanDefaultSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Pool Subnet mask "
::= { voipLanEntry 9 }
voipLanLeaseTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lease Time "
::= { voipLanEntry 10 }
voipLanDNS OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
manual(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server Assignment"
::= { voipLanEntry 11 }
voipLanPriDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server (Primary) IP "
::= { voipLanEntry 12 }
voipLanSecDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Domain Name Server (Secondary) IP"
::= { voipLanEntry 13 }
--
-- VoIP SIP Proxy Server Table
--
voipSIPProxyTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSIPProxyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP LAN Setup Table"
::= { voip-card 3 }
voipSIPProxyEntry OBJECT-TYPE
SYNTAX VoipSIPProxyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Proxy Sever entry"
INDEX { voipSIPProxyIndex ,voipSIPProxyType}
::= { voipSIPProxyTable 1 }
VoipSIPProxyEntry ::= SEQUENCE {
voipSIPProxyIndex LargeSlotIndex,
voipSIPProxyType INTEGER,
voipSIPProxyEnable INTEGER,
voipSIPProxyDomainIP DisplayString,
voipSIPProxyPort INTEGER,
voipSIPProxyRealm DisplayString,
voipSIPProxyTTL INTEGER,
voipSIPProxySIPDomain DisplayString,
voipSIPProxyDomainReg INTEGER
}
voipSIPProxyIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipSIPProxyEntry 1 }
voipSIPProxyType OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
redundant(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SIP Proxy Server Type"
::= { voipSIPProxyEntry 2 }
voipSIPProxyEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable SIP Proxy"
::= { voipSIPProxyEntry 3 }
voipSIPProxyDomainIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Proxy Server IP / Domain"
::= { voipSIPProxyEntry 4 }
voipSIPProxyPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Proxy Server Port "
::= { voipSIPProxyEntry 5 }
voipSIPProxyRealm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Proxy Server Realm"
::= { voipSIPProxyEntry 6 }
voipSIPProxyTTL OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"TTL (Registration interval) "
::= { voipSIPProxyEntry 7 }
voipSIPProxySIPDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SIP Domain"
::= { voipSIPProxyEntry 8 }
voipSIPProxyDomainReg OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Use Domain to Register"
::= { voipSIPProxyEntry 9 }
--
-- VoIP SIP Representative Table
--
voipRepresentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipRepresentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP LAN Setup Table"
::= { voip-card 4 }
voipRepresentEntry OBJECT-TYPE
SYNTAX VoipRepresentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Proxy Sever entry"
INDEX { voipRepresentIndex}
::= { voipRepresentTable 1 }
VoipRepresentEntry ::= SEQUENCE {
voipRepresentIndex LargeSlotIndex,
voipRepresentEnable INTEGER,
voipRepresentNumber DisplayString,
voipRepresentAccount DisplayString,
voipRepresentPW DisplayString,
voipRepresentFxoEnable INTEGER,
voipRepresentFxoNumber DisplayString,
voipRepresentFxoAccount DisplayString,
voipRepresentFxoPW DisplayString
}
voipRepresentIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipRepresentEntry 1 }
voipRepresentEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable SIP Representative Number"
::= { voipRepresentEntry 2 }
voipRepresentNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number"
::= { voipRepresentEntry 3 }
voipRepresentAccount OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Account"
::= { voipRepresentEntry 4 }
voipRepresentPW OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Password"
::= { voipRepresentEntry 5 }
voipRepresentFxoEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable SIP Representative FXS Enable"
::= { voipRepresentEntry 6 }
voipRepresentFxoNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Number"
::= { voipRepresentEntry 7 }
voipRepresentFxoAccount OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Account"
::= { voipRepresentEntry 8 }
voipRepresentFxoPW OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS Password"
::= { voipRepresentEntry 9 }
--
-- VoIP SIP Register Table
--
voipSIPRegisterTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSIPRegisterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP LAN Setup Table"
::= { voip-card 5 }
voipSIPRegisterEntry OBJECT-TYPE
SYNTAX VoipSIPRegisterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Proxy Sever entry"
INDEX { voipSIPRegisterIndex ,voipSIPRegisterLine}
::= { voipSIPRegisterTable 1 }
VoipSIPRegisterEntry ::= SEQUENCE {
voipSIPRegisterIndex LargeSlotIndex,
voipSIPRegisterLine INTEGER,
voipSIPRegisterEnable INTEGER,
voipSIPRegisterNumber DisplayString,
voipSIPRegisterAccount DisplayString,
voipSIPRegisterPW DisplayString,
voipSIPRegisterInvite INTEGER,
voipSIPRegisterHunt INTEGER
}
voipSIPRegisterIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipSIPRegisterEntry 1 }
voipSIPRegisterLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line No"
::= { voipSIPRegisterEntry 2 }
voipSIPRegisterEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable"
::= { voipSIPRegisterEntry 3 }
voipSIPRegisterNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number"
::= { voipSIPRegisterEntry 4 }
voipSIPRegisterAccount OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Account"
::= { voipSIPRegisterEntry 5 }
voipSIPRegisterPW OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Password"
::= { voipSIPRegisterEntry 6 }
voipSIPRegisterInvite OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Invite with ID / Account"
::= { voipSIPRegisterEntry 7 }
voipSIPRegisterHunt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hunt Group"
::= { voipSIPRegisterEntry 8 }
--
-- VoIP SIP Outbound Proxy Table
--
voipSIPOutboundTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSIPOutboundEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Outbound Proxy Table"
::= { voip-card 6 }
voipSIPOutboundEntry OBJECT-TYPE
SYNTAX VoipSIPOutboundEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Outbound Proxy entry"
INDEX { voipSIPOutboundIndex}
::= { voipSIPOutboundTable 1 }
VoipSIPOutboundEntry ::= SEQUENCE {
voipSIPOutboundIndex LargeSlotIndex,
voipSIPOutboundEnable INTEGER,
voipSIPOutboundDomain DisplayString,
voipSIPOutboundPort INTEGER
}
voipSIPOutboundIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipSIPOutboundEntry 1 }
voipSIPOutboundEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Outbound Proxy Support"
::= { voipSIPOutboundEntry 2 }
voipSIPOutboundDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Outbound Proxy IP / Domain"
::= { voipSIPOutboundEntry 3 }
voipSIPOutboundPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Outbound Proxy Port"
::= { voipSIPOutboundEntry 4 }
--
-- VoIP SIP Advanced Table
--
voipSIPAdvTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSIPAdvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 7 }
voipSIPAdvEntry OBJECT-TYPE
SYNTAX VoipSIPAdvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipSIPAdvIndex}
::= { voipSIPAdvTable 1 }
VoipSIPAdvEntry ::= SEQUENCE {
voipSIPAdvIndex LargeSlotIndex,
voipSIPAdvProtocol INTEGER,
voipSIPAdvRFC3986 INTEGER,
voipSIPAdvInbox INTEGER,
voipSIPAdvSipProxy INTEGER,
voipSIPAdvExpiration INTEGER,
voipSIPAdvRefreshReq INTEGER,
voipSIPAdvRefresher INTEGER
}
voipSIPAdvIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipSIPAdvEntry 1 }
voipSIPAdvProtocol OBJECT-TYPE
SYNTAX INTEGER {
udp(1),
tcp(2),
tls(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SIP Transport Protocol"
::= { voipSIPAdvEntry 2 }
voipSIPAdvRFC3986 OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Support URI Percent-Encoding (RFC 3986)"
::= { voipSIPAdvEntry 3 }
voipSIPAdvInbox OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable Non-SIP Inbox Call"
::= { voipSIPAdvEntry 4 }
voipSIPAdvSipProxy OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable Support SIP Proxy "
::= { voipSIPAdvEntry 5 }
voipSIPAdvExpiration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Session Expiration "
::= { voipSIPAdvEntry 6 }
voipSIPAdvRefreshReq OBJECT-TYPE
SYNTAX INTEGER {
update(1),
reInvite(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Session Refresh Request "
::= { voipSIPAdvEntry 7 }
voipSIPAdvRefresher OBJECT-TYPE
SYNTAX INTEGER {
uas(1),
uac(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Session Refresher"
::= { voipSIPAdvEntry 8 }
--
-- VoIP Codec Option Table
--
voipCodecOptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCodecOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 8 }
voipCodecOptionEntry OBJECT-TYPE
SYNTAX VoipCodecOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipCodecOptionIndex}
::= { voipCodecOptionTable 1 }
VoipCodecOptionEntry ::= SEQUENCE {
voipCodecOptionIndex LargeSlotIndex,
voipCodecOptionJitter INTEGER,
voipCodecOptionSC INTEGER,
voipCodecOptionEcho INTEGER,
voipCodecOptionRXTP INTEGER,
voipCodecOptionG723 INTEGER,
voipCodecOptionG726 INTEGER
}
voipCodecOptionIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCodecOptionEntry 1 }
voipCodecOptionJitter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Jitter Buffer "
::= { voipCodecOptionEntry 2 }
voipCodecOptionSC OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Silence Detection / Suppression"
::= { voipCodecOptionEntry 3 }
voipCodecOptionEcho OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Echo Cancellation"
::= { voipCodecOptionEntry 4 }
voipCodecOptionRXTP OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable RTCP-XR (RFC 3611)"
::= { voipCodecOptionEntry 5 }
voipCodecOptionG723 OBJECT-TYPE
SYNTAX INTEGER {
r64000(1),
r53000(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G.723 6.4k/5.3k"
::= { voipCodecOptionEntry 6 }
voipCodecOptionG726 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"G726 Dynamic paylod Type(1-99)"
::= { voipCodecOptionEntry 7 }
--
-- VoIP Codec Setup Table
--
voipCodecTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCodecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 9 }
voipCodecEntry OBJECT-TYPE
SYNTAX VoipCodecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipCodecIndex,voipCodecItem }
::= { voipCodecTable 1 }
VoipCodecEntry ::= SEQUENCE {
voipCodecIndex LargeSlotIndex,
voipCodecItem INTEGER,
voipCodecPriority INTEGER,
voipCodecEnable INTEGER,
voipCodecInterval INTEGER
}
voipCodecIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCodecEntry 1 }
voipCodecItem OBJECT-TYPE
SYNTAX INTEGER {
g711uLaw(1),
g723(2),
g726(3),
g729(4),
g711aLaw(5),
gsm(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Codec"
::= { voipCodecEntry 2 }
voipCodecPriority OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Priority "
::= { voipCodecEntry 3 }
voipCodecEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable"
::= { voipCodecEntry 4 }
voipCodecInterval OBJECT-TYPE
SYNTAX INTEGER {
ms10sec(1),
ms20sec(2),
ms30sec(3),
ms40sec(4),
ms50sec(5),
ms60sec(6),
ms70sec(7),
ms80sec(8),
ms90sec(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Packet Interval (ms)"
::= { voipCodecEntry 5 }
--
-- VoIP DTMF Setup Table
--
voipDtmfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 10 }
voipDtmfEntry OBJECT-TYPE
SYNTAX VoipDtmfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipDtmfIndex}
::= { voipDtmfTable 1 }
VoipDtmfEntry ::= SEQUENCE {
voipDtmfIndex LargeSlotIndex,
voipDtmfOutOfBand INTEGER,
voipDtmfOutOfBandMode INTEGER,
voipDtmfOnLength INTEGER,
voipDtmfOffLength INTEGER
}
voipDtmfIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipDtmfEntry 1 }
voipDtmfOutOfBand OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Enable Out-of-Band DTMF"
::= { voipDtmfEntry 2 }
voipDtmfOutOfBandMode OBJECT-TYPE
SYNTAX INTEGER {
rfc2833(1),
sipInfo(2),
rfc2833Force(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Out-of-Band DTMF"
::= { voipDtmfEntry 3 }
voipDtmfOnLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum DTMF ON Length"
::= { voipDtmfEntry 4 }
voipDtmfOffLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum DTMF OFF Length"
::= { voipDtmfEntry 5 }
--
-- VoIP Hot Line Table
--
voipHotLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipHotLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 11 }
voipHotLineEntry OBJECT-TYPE
SYNTAX VoipHotLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipHotLineIndex, voipHotLineLine }
::= { voipHotLineTable 1 }
VoipHotLineEntry ::= SEQUENCE {
voipHotLineIndex LargeSlotIndex,
voipHotLineLine INTEGER,
voipHotLineEnable INTEGER,
voipHotLineDelay INTEGER,
voipHotLineNumber DisplayString
}
voipHotLineIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipHotLineEntry 1 }
voipHotLineLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line ID"
::= { voipHotLineEntry 2 }
voipHotLineEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable Hot Line"
::= { voipHotLineEntry 3}
voipHotLineDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Warm Line(Hot Line Delay) "
::= { voipHotLineEntry 4}
voipHotLineNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hot Line No."
::= { voipHotLineEntry 5}
--
-- VoIP Phone Book Table
--
voipPhoneBookTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipPhoneBookEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced Table"
::= { voip-card 12 }
voipPhoneBookEntry OBJECT-TYPE
SYNTAX VoipPhoneBookEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipPhoneBookIndex, voipPhoneBookItem }
::= { voipPhoneBookTable 1 }
VoipPhoneBookEntry ::= SEQUENCE {
voipPhoneBookIndex LargeSlotIndex,
voipPhoneBookItem INTEGER,
voipPhoneBookName DisplayString,
voipPhoneBookNumber DisplayString,
voipPhoneBookDomain DisplayString,
voipPhoneBookPort INTEGER
}
voipPhoneBookIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipPhoneBookEntry 1 }
voipPhoneBookItem OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Item ID"
::= { voipPhoneBookEntry 2 }
voipPhoneBookName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway Name"
::= { voipPhoneBookEntry 3}
voipPhoneBookNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway Number"
::= { voipPhoneBookEntry 4}
voipPhoneBookDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP / Domain Name"
::= { voipPhoneBookEntry 5}
voipPhoneBookPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port"
::= { voipPhoneBookEntry 6}
--
-- VoIP Digital Map Option Table
--
voipDigMapOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipDigMapOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Digital Map Option Table"
::= { voip-card 13 }
voipDigMapOpEntry OBJECT-TYPE
SYNTAX VoipDigMapOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Digital Map Option entry"
INDEX { voipDigMapOpSlot }
::= { voipDigMapOpTable 1 }
VoipDigMapOpEntry ::= SEQUENCE {
voipDigMapOpSlot LargeSlotIndex,
voipDigMapOpAlert INTEGER,
voipDigMapOpPound INTEGER,
voipDigMapOpDialLen INTEGER,
voipDigMapOpCallRoute INTEGER
}
voipDigMapOpSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipDigMapOpEntry 1 }
voipDigMapOpAlert OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alert if Auto fails"
::= { voipDigMapOpEntry 2 }
voipDigMapOpPound OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable Pound Key"
::= { voipDigMapOpEntry 3 }
voipDigMapOpDialLen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max. Dial Length"
::= { voipDigMapOpEntry 4 }
voipDigMapOpCallRoute OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
voip(2),
pstn(3),
deny(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default Call Route "
::= { voipDigMapOpEntry 5 }
--
-- VoIP Digital Map Table
--
voipDigMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipDigMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Digital Map Table"
::= { voip-card 14 }
voipDigMapEntry OBJECT-TYPE
SYNTAX VoipDigMapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Digital Map entry"
INDEX { voipDigMapSlot, voipDigMapItem }
::= { voipDigMapTable 1 }
VoipDigMapEntry ::= SEQUENCE {
voipDigMapSlot LargeSlotIndex,
voipDigMapItem INTEGER,
voipDigMapEnable INTEGER,
voipDigMapScanCode DisplayString,
voipDigMapVoipDial DisplayString,
voipDigMapPstnDial DisplayString,
voipDigMapDialLen INTEGER,
voipDigMapDialRoute INTEGER,
voipBackupEnable INTEGER,
voipBackupPrefix DisplayString,
voipBackupDomainIP DisplayString,
voipBackupPort INTEGER
}
voipDigMapSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipDigMapEntry 1 }
voipDigMapItem OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Item ID"
::= { voipDigMapEntry 2 }
voipDigMapEnable OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Item ID"
::= { voipDigMapEntry 3 }
voipDigMapScanCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway Name"
::= { voipDigMapEntry 4}
voipDigMapVoipDial OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway Number"
::= { voipDigMapEntry 5}
voipDigMapPstnDial OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP / Domain Name"
::= { voipDigMapEntry 6}
voipDigMapDialLen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Dial Length"
::= { voipDigMapEntry 7}
voipDigMapDialRoute OBJECT-TYPE
SYNTAX INTEGER{
auto(1),
voip(2),
pstn(3),
deny(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Route Mode"
::= { voipDigMapEntry 8}
voipBackupEnable OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port"
::= { voipDigMapEntry 9}
voipBackupPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port"
::= { voipDigMapEntry 10}
voipBackupDomainIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port"
::= { voipDigMapEntry 11}
voipBackupPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port"
::= { voipDigMapEntry 12}
--
-- VoIP Command Control Table
--
voipCommandTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { voip-card 15 }
voipCommandEntry OBJECT-TYPE
SYNTAX VoipCommandEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { voipCommandIndex }
::= { voipCommandTable 1 }
VoipCommandEntry ::= SEQUENCE {
voipCommandIndex LargeSlotIndex,
voipCommandReset INTEGER,
voipCommandLoadDefault INTEGER,
voipCommandVoipReset INTEGER,
voipCommandReload INTEGER
}
voipCommandIndex OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCommandEntry 1 }
voipCommandLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default VOIP CONF"
::= { voipCommandEntry 2 }
voipCommandReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Card Reset"
::= { voipCommandEntry 3 }
voipCommandVoipReset OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
reset(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: VOIP Reset"
::= { voipCommandEntry 4 }
voipCommandReload OBJECT-TYPE
SYNTAX INTEGER {
no(0), --//RIKER2021 SilverCreek
reload(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Reload Config"
::= { voipCommandEntry 5 }
--
-- VoIP Ethernet phy table
--
voipEthPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipEthPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Eth phy electric Table."
::= { voip-card 16 }
voipEthPortEntry OBJECT-TYPE
SYNTAX VoipEthPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Eth Phy Config Entry."
INDEX { voipEthSlot , voipEthPort }
::= { voipEthPortTable 1 }
VoipEthPortEntry ::= SEQUENCE {
voipEthSlot LargeSlotIndex,
voipEthPort INTEGER,
voipEthLinkup INTEGER,
voipEthSpeed INTEGER,
voipEthDuplex INTEGER
}
voipEthSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipEthPortEntry 1 }
voipEthPort OBJECT-TYPE
SYNTAX INTEGER {
wan (1),
lan1 (2),
lan2 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"eth port WAN LAN1 LAN2"
::= { voipEthPortEntry 2 }
voipEthLinkup OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port Linkup"
::= { voipEthPortEntry 3 }
voipEthSpeed OBJECT-TYPE
SYNTAX INTEGER {
speed10mbps (1),
speed100mbps (2),
speed1000mbps (3),
na(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port speed 10/100/1000 mbps"
::= { voipEthPortEntry 4 }
voipEthDuplex OBJECT-TYPE
SYNTAX INTEGER {
half (1),
full (2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"port duplex mode(half/full)"
::= { voipEthPortEntry 5 }
--
-- VoIP Voice Control Table
--
voipVoiceControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipVoiceControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Voice Control Table"
::= { voip-card 17 }
voipVoiceControlEntry OBJECT-TYPE
SYNTAX VoipVoiceControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP advanced entry"
INDEX { voipVoiceControlSlot}
::= { voipVoiceControlTable 1 }
VoipVoiceControlEntry ::= SEQUENCE {
voipVoiceControlSlot LargeSlotIndex,
voipVoiceControlAulaw INTEGER,
voipVoiceControlFxs INTEGER
}
voipVoiceControlSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipVoiceControlEntry 1 }
voipVoiceControlAulaw OBJECT-TYPE
SYNTAX INTEGER {
alaw(1),
ulaw(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A u Law"
::= { voipVoiceControlEntry 2 }
voipVoiceControlFxs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"max FXS channel"
::= { voipVoiceControlEntry 3 }
--
-- VoIP RTP Summary table
--
voipRtpSumTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipRtpSumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RTP Summary Table."
::= { voip-card 18 }
voipRtpSumEntry OBJECT-TYPE
SYNTAX VoipRtpSumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"RTP Summary Entry."
INDEX { voipRtpSumSlot , voipRtpSumLine }
::= { voipRtpSumTable 1 }
VoipRtpSumEntry ::= SEQUENCE {
voipRtpSumSlot LargeSlotIndex,
voipRtpSumLine INTEGER,
voipRtpSumCodec INTEGER,
voipRtpSumIP INTEGER,
voipRtpSumPort INTEGER,
voipRtpSumPktSend INTEGER,
voipRtpSumPktRcv INTEGER,
voipRtpSumLost INTEGER,
voipRtpSumJitter INTEGER,
voipRtpSumByteSend INTEGER,
voipRtpSumByteRcv INTEGER,
voipRtpSumPeerSend INTEGER
}
voipRtpSumSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
MAX-ACCESS read-only --//RIKER2021 SilverCreek
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipRtpSumEntry 1 }
voipRtpSumLine OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only --//RIKER2021 SilverCreek
STATUS current
DESCRIPTION
"Line Numner"
::= { voipRtpSumEntry 2 }
voipRtpSumCodec OBJECT-TYPE
SYNTAX INTEGER {
g711uLaw (1),
g723(2),
g726and32k(3),
g729(4),
g711alaw(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Codec"
::= { voipRtpSumEntry 3 }
voipRtpSumIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IP"
::= { voipRtpSumEntry 4 }
voipRtpSumPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Port"
::= { voipRtpSumEntry 5 }
voipRtpSumPktSend OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packer Send"
::= { voipRtpSumEntry 6 }
voipRtpSumPktRcv OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packer Receive"
::= { voipRtpSumEntry 7 }
voipRtpSumLost OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packer Lost"
::= { voipRtpSumEntry 8 }
voipRtpSumJitter OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Jitter"
::= { voipRtpSumEntry 9 }
voipRtpSumByteSend OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Byte Send"
::= { voipRtpSumEntry 10 }
voipRtpSumByteRcv OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Byte Receive"
::= { voipRtpSumEntry 11 }
voipRtpSumPeerSend OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peer Say Send Pakcet"
::= { voipRtpSumEntry 12 }
--
-- VoIP FAX Mode Table
--
voipFaxModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipFaxModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP FAX Mode Table"
::= { voip-card 19 }
voipFaxModeEntry OBJECT-TYPE
SYNTAX VoipFaxModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP FAX Mode entry"
INDEX { voipFaxModeSlot, voipFaxModeLine }
::= { voipFaxModeTable 1 }
VoipFaxModeEntry ::= SEQUENCE {
voipFaxModeSlot LargeSlotIndex,
voipFaxModeLine INTEGER,
voipFaxMode INTEGER
}
voipFaxModeSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipFaxModeEntry 1 }
voipFaxModeLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line"
::= { voipFaxModeEntry 2 }
voipFaxMode OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
t38fax(2),
t30fax(3),
t30modem(4),
t30only(5),
t38native(6),
t30v152(7),
t30v25(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FAX Mode"
::= { voipFaxModeEntry 3 }
--
-- VoIP FAX Option Table
--
voipFaxOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipFaxOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP FAX Option Table"
::= { voip-card 20 }
voipFaxOpEntry OBJECT-TYPE
SYNTAX VoipFaxOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP FAX Option entry"
INDEX { voipFaxOpSlot}
::= { voipFaxOpTable 1 }
VoipFaxOpEntry ::= SEQUENCE {
voipFaxOpSlot LargeSlotIndex,
voipFaxOpCED INTEGER,
voipFaxOpT38 INTEGER,
voipFaxOpSense INTEGER,
voipFaxOpHighSpeed INTEGER,
voipFaxOpLowSpeed INTEGER,
voipFaxOpMaxRate INTEGER,
voipFaxOpPacketTime INTEGER,
voipFaxOpDelay INTEGER,
voipFaxOpFaxCodec INTEGER,
voipFaxOpPayload INTEGER,
voipFaxOpJitter INTEGER
}
voipFaxOpSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipFaxOpEntry 1 }
voipFaxOpCED OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch FAX On CED Detection"
::= { voipFaxOpEntry 2 }
voipFaxOpT38 OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Restrict T.38"
::= { voipFaxOpEntry 3}
voipFaxOpSense OBJECT-TYPE
SYNTAX INTEGER {
n2(1),
n1(2),
zero(3),
p1(4),
p2(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FAX Detection Sensitivity"
::= { voipFaxOpEntry 4}
voipFaxOpHighSpeed OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
two(3),
three(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"High Speed Redundancy "
::= { voipFaxOpEntry 5}
voipFaxOpLowSpeed OBJECT-TYPE
SYNTAX INTEGER {
zero(1),
one(2),
two(3),
three(4),
four(5),
five(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Low Speed Redundancy "
::= { voipFaxOpEntry 6}
voipFaxOpMaxRate OBJECT-TYPE
SYNTAX INTEGER {
r2400(1),
r4800(2),
r7200(3),
r9600(4),
r12000(5),
r14400(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FAX Max Rate "
::= { voipFaxOpEntry 7}
voipFaxOpPacketTime OBJECT-TYPE
SYNTAX INTEGER {
p10(1),
p20(2),
p30(3),
p40(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"High Speed Packet Time"
::= { voipFaxOpEntry 8}
voipFaxOpDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Audio Rollback Delay"
::= { voipFaxOpEntry 9}
voipFaxOpFaxCodec OBJECT-TYPE
SYNTAX INTEGER{
g711ulaw(1),
g711alaw(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FAX Codec "
::= { voipFaxOpEntry 10}
voipFaxOpPayload OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"T.30 V.152 Payload Type"
::= { voipFaxOpEntry 11}
voipFaxOpJitter OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FAX Jitter Buffer"
::= { voipFaxOpEntry 12}
--
-- VoIP SIP Proxy Option Table
--
voipSipProxyOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipSipProxyOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Proxy Option Table"
::= { voip-card 21 }
voipSipProxyOpEntry OBJECT-TYPE
SYNTAX VoipSipProxyOpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP SIP Proxy Option entry"
INDEX { voipSipProxyOpSlot}
::= { voipSipProxyOpTable 1 }
VoipSipProxyOpEntry ::= SEQUENCE {
voipSipProxyOpSlot LargeSlotIndex,
voipSipProxyOpBind INTEGER,
voipSipProxyOpUnreg INTEGER,
voipSipProxyOpUnregAll INTEGER,
voipSipProxyOpSipAuth INTEGER,
voipSipProxyOpInvite INTEGER,
voipSipProxyOpMWI INTEGER
}
voipSipProxyOpSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipSipProxyOpEntry 1 }
voipSipProxyOpBind OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bind Proxy Interval for NAT"
::= { voipSipProxyOpEntry 2 }
voipSipProxyOpUnreg OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initial Unregister"
::= { voipSipProxyOpEntry 3 }
voipSipProxyOpUnregAll OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unregister All Contacts"
::= { voipSipProxyOpEntry 4 }
voipSipProxyOpSipAuth OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Keep SIP Auth"
::= { voipSipProxyOpEntry 5 }
voipSipProxyOpInvite OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Keep INVITE Auth"
::= { voipSipProxyOpEntry 6 }
voipSipProxyOpMWI OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Support Message Waiting Indication (MWI)"
::= { voipSipProxyOpEntry 7 }
--
-- VoIP UPnP NAT Traversal Table
--
voipUpnpNatTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipUpnpNatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP UPnP NAT Traversal Table"
::= { voip-card 22 }
voipUpnpNatEntry OBJECT-TYPE
SYNTAX VoipUpnpNatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP UPnP NAT Traversal entry"
INDEX { voipUpnpNatSlot}
::= { voipUpnpNatTable 1 }
VoipUpnpNatEntry ::= SEQUENCE {
voipUpnpNatSlot LargeSlotIndex,
voipUpnpNatEnableUpnp INTEGER,
voipUpnpNatEnableNat INTEGER,
voipUpnpNatNatIP DisplayString,
voipUpnpNatEnableStun INTEGER,
voipUpnpNatStunIP DisplayString,
voipUpnpNatStunPort INTEGER
}
voipUpnpNatSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipUpnpNatEntry 1 }
voipUpnpNatEnableUpnp OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable UPnP"
::= { voipUpnpNatEntry 2 }
voipUpnpNatEnableNat OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable NAT Public IP"
::= { voipUpnpNatEntry 3 }
voipUpnpNatNatIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP/Domain "
::= { voipUpnpNatEntry 4 }
voipUpnpNatEnableStun OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable STUN Client"
::= { voipUpnpNatEntry 5 }
voipUpnpNatStunIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STUN Server IP / Domain"
::= { voipUpnpNatEntry 6 }
voipUpnpNatStunPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"STUN Server Port"
::= { voipUpnpNatEntry 7 }
--
-- VoIP Status Table
--
voipStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Status Table"
::= { voip-card 23 }
voipStatusEntry OBJECT-TYPE
SYNTAX VoipStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Status entry"
INDEX { voipStatusSlot,
voipStatusLine}
::= { voipStatusTable 1 }
VoipStatusEntry ::= SEQUENCE {
voipStatusSlot LargeSlotIndex,
voipStatusLine INTEGER,
voipStatusType INTEGER,
voipStatusNumber DisplayString,
voipStatusState INTEGER,
voipStatusCalls INTEGER,
voipStatusReg INTEGER
}
voipStatusSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipStatusEntry 1 }
voipStatusLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line number"
::= { voipStatusEntry 2 }
voipStatusType OBJECT-TYPE
SYNTAX INTEGER {
fxs(1),
fxo(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type"
::= { voipStatusEntry 3 }
voipStatusNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number "
::= { voipStatusEntry 4 }
voipStatusState OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
error(2),
disable(3),
idle(4),
getDtmf(5),
regQuery(6),
dnsQuery(7),
inviting(8),
ringback(9),
callerIdRing(10),
callerIdSending(11),
callerIdSent(12),
alerting(13),
answering(14),
talking(15),
playBusyTone(16)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State"
::= { voipStatusEntry 5 }
voipStatusCalls OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Calls"
::= { voipStatusEntry 6 }
voipStatusReg OBJECT-TYPE
SYNTAX INTEGER{
disable(1),
proceeding(2),
success(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Register "
::= { voipStatusEntry 7 }
--
-- VoIP Calling Feature Representative Table
--
voipCallRepresentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCallRepresentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature Represent Table"
::= { voip-card 24 }
voipCallRepresentEntry OBJECT-TYPE
SYNTAX VoipCallRepresentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature Represent entry"
INDEX { voipCallRepresentSlot}
::= { voipCallRepresentTable 1 }
VoipCallRepresentEntry ::= SEQUENCE {
voipCallRepresentSlot LargeSlotIndex,
voipFxsUncondition INTEGER,
voipFxsUnconditionParam DisplayString,
voipFxsBusy INTEGER,
voipFxsBusyParam DisplayString,
voipFxoUncondition INTEGER,
voipFxoUnconditionParam DisplayString,
voipFxoBusy INTEGER,
voipFxoBusyParam DisplayString
}
voipCallRepresentSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCallRepresentEntry 1 }
voipFxsUncondition OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable FXS uncondtion forward"
::= { voipCallRepresentEntry 2 }
voipFxsUnconditionParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS uncondtion forward parameter"
::= { voipCallRepresentEntry 3 }
voipFxsBusy OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable FXS busy forward"
::= { voipCallRepresentEntry 4 }
voipFxsBusyParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXS busy forward parameter"
::= { voipCallRepresentEntry 5 }
voipFxoUncondition OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable FXO uncondtion forward"
::= { voipCallRepresentEntry 6 }
voipFxoUnconditionParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXO uncondtion forward parameter"
::= { voipCallRepresentEntry 7 }
voipFxoBusy OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable FXO busy forward"
::= { voipCallRepresentEntry 8 }
voipFxoBusyParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FXO busy forward parameter"
::= { voipCallRepresentEntry 9 }
--
-- VoIP Calling Feature Table
--
voipCallFeatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCallFeatureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature Table"
::= { voip-card 25 }
voipCallFeatureEntry OBJECT-TYPE
SYNTAX VoipCallFeatureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature entry"
INDEX { voipCallFeatureSlot, voipCallFeatureLine }
::= { voipCallFeatureTable 1 }
VoipCallFeatureEntry ::= SEQUENCE {
voipCallFeatureSlot LargeSlotIndex,
voipCallFeatureLine INTEGER,
voipNotDisturb INTEGER,
voipUnconditionEnable INTEGER,
voipUnconditionParam DisplayString,
voipBusyEnable INTEGER,
voipBusyParam DisplayString,
voipNoAnswerEnable INTEGER,
voipNoAnswerParam DisplayString
}
voipCallFeatureSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCallFeatureEntry 1 }
voipCallFeatureLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line ID"
::= { voipCallFeatureEntry 2 }
voipNotDisturb OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Do Not Disturb"
::= { voipCallFeatureEntry 3}
voipUnconditionEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unconditional Forward"
::= { voipCallFeatureEntry 4}
voipUnconditionParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unconditional Forward Parameter"
::= { voipCallFeatureEntry 5}
voipBusyEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Busy Forward"
::= { voipCallFeatureEntry 6}
voipBusyParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Busy Forward Parameter"
::= { voipCallFeatureEntry 7}
voipNoAnswerEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"No Answer Forward "
::= { voipCallFeatureEntry 8}
voipNoAnswerParam OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"No Answer Forward Parameter"
::= { voipCallFeatureEntry 9}
--
-- VoIP Calling Feature Option Table
--
voipCallOptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCallOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature Option Table"
::= { voip-card 26 }
voipCallOptionEntry OBJECT-TYPE
SYNTAX VoipCallOptionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Calling Feature Option entry"
INDEX { voipCallOptionSlot, voipCallOptionLine }
::= { voipCallOptionTable 1 }
VoipCallOptionEntry ::= SEQUENCE {
voipCallOptionSlot LargeSlotIndex,
voipCallOptionLine INTEGER,
voipCallHold INTEGER,
voipCallTransfer INTEGER,
voipCallWaiting INTEGER,
voipLoalMixer INTEGER,
voipNoAnswerTime INTEGER
}
voipCallOptionSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCallOptionEntry 1 }
voipCallOptionLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line ID"
::= { voipCallOptionEntry 2 }
voipCallHold OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Call Hold"
::= { voipCallOptionEntry 3}
voipCallTransfer OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Call Transfer"
::= { voipCallOptionEntry 4}
voipCallWaiting OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Call Waiting"
::= { voipCallOptionEntry 5}
voipLoalMixer OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local Mixer"
::= { voipCallOptionEntry 6}
voipNoAnswerTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"No Answer Time"
::= { voipCallOptionEntry 7}
--
-- VoIP Ring Cadence Table
--
voipRingCadenceTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipRingCadenceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Ring Cadence Table"
::= { voip-card 27 }
voipRingCadenceEntry OBJECT-TYPE
SYNTAX VoipRingCadenceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Ring Cadence entry"
INDEX { voipRingCadenceSlot}
::= { voipRingCadenceTable 1 }
VoipRingCadenceEntry ::= SEQUENCE {
voipRingCadenceSlot LargeSlotIndex,
voipRingCadenceR1On1 INTEGER,
voipRingCadenceR1Off1 INTEGER,
voipRingCadenceR1On2 INTEGER,
voipRingCadenceR1Off2 INTEGER,
voipRingCadenceR1On3 INTEGER,
voipRingCadenceR1Off3 INTEGER,
voipRingCadenceR2On1 INTEGER,
voipRingCadenceR2Off1 INTEGER,
voipRingCadenceR2On2 INTEGER,
voipRingCadenceR2Off2 INTEGER,
voipRingCadenceR2On3 INTEGER,
voipRingCadenceR2Off3 INTEGER,
voipRingCadenceR3On1 INTEGER,
voipRingCadenceR3Off1 INTEGER,
voipRingCadenceR3On2 INTEGER,
voipRingCadenceR3Off2 INTEGER,
voipRingCadenceR3On3 INTEGER,
voipRingCadenceR3Off3 INTEGER
}
voipRingCadenceSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipRingCadenceEntry 1 }
voipRingCadenceR1On1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 On1"
::= { voipRingCadenceEntry 2 }
voipRingCadenceR1Off1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 Off1"
::= { voipRingCadenceEntry 3}
voipRingCadenceR1On2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 On2"
::= { voipRingCadenceEntry 4 }
voipRingCadenceR1Off2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 Off2"
::= { voipRingCadenceEntry 5}
voipRingCadenceR1On3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 On3"
::= { voipRingCadenceEntry 6 }
voipRingCadenceR1Off3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 Off3"
::= { voipRingCadenceEntry 7}
voipRingCadenceR2On1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 2 On1"
::= { voipRingCadenceEntry 8 }
voipRingCadenceR2Off1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 2 Off1"
::= { voipRingCadenceEntry 9}
voipRingCadenceR2On2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 2 On2"
::= { voipRingCadenceEntry 10}
voipRingCadenceR2Off2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 1 Off2"
::= { voipRingCadenceEntry 11}
voipRingCadenceR2On3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 2 On3"
::= { voipRingCadenceEntry 12 }
voipRingCadenceR2Off3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 2 Off3"
::= { voipRingCadenceEntry 13}
voipRingCadenceR3On1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 On1"
::= { voipRingCadenceEntry 14 }
voipRingCadenceR3Off1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 Off1"
::= { voipRingCadenceEntry 15}
voipRingCadenceR3On2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 On2"
::= { voipRingCadenceEntry 16 }
voipRingCadenceR3Off2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 Off2"
::= { voipRingCadenceEntry 17}
voipRingCadenceR3On3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 On3"
::= { voipRingCadenceEntry 18 }
voipRingCadenceR3Off3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence Range 3 Off3"
::= { voipRingCadenceEntry 19}
--
-- VoIP Line Setting Table
--
voipLineSettingTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipLineSettingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Line Setting Table"
::= { voip-card 28 }
voipLineSettingEntry OBJECT-TYPE
SYNTAX VoipLineSettingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Line Setting entry"
INDEX { voipLineSettingSlot, voipLineSettingLine }
::= { voipLineSettingTable 1 }
VoipLineSettingEntry ::= SEQUENCE {
voipLineSettingSlot LargeSlotIndex,
voipLineSettingLine INTEGER,
voipLineSetRingCadence INTEGER
}
voipLineSettingSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipLineSettingEntry 1 }
voipLineSettingLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line ID"
::= { voipLineSettingEntry 2 }
voipLineSetRingCadence OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
three(3),
na(256)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ring Cadence"
::= { voipLineSettingEntry 3}
--
-- VoIP Caller ID Table
--
voipCallerIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoipCallerIdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Caller ID Table"
::= { voip-card 29 }
voipCallerIdEntry OBJECT-TYPE
SYNTAX VoipCallerIdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"VoIP Caller ID entry"
INDEX { voipCallerIdSlot}
::= { voipCallerIdTable 1 }
VoipCallerIdEntry ::= SEQUENCE {
voipCallerIdSlot LargeSlotIndex,
voipCallerIdFxsMode INTEGER,
voipCallerIdFirstRing INTEGER,
voipCallerIdFskMode INTEGER,
voipCallerIdFxoDetect INTEGER
}
voipCallerIdSlot OBJECT-TYPE
SYNTAX LargeSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { voipCallerIdEntry 1 }
voipCallerIdFxsMode OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
dtmf(2),
fsk(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable UPnP"
::= { voipCallerIdEntry 2 }
voipCallerIdFirstRing OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable NAT Public IP"
::= { voipCallerIdEntry 3 }
voipCallerIdFskMode OBJECT-TYPE
SYNTAX INTEGER {
bellcore(1),
etsi(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAT IP/Domain "
::= { voipCallerIdEntry 4 }
voipCallerIdFxoDetect OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable STUN Client"
::= { voipCallerIdEntry 5 }
voipTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total cards of VoIP "
::= { voip-card 100 }
--============================================================================--
--============================================================================--
--======================================================================--
--======================================================================--
-- 3rs232a-card MIB
--======================================================================--
--======================================================================--
--
-- 6RS232A Configuration
--
trirs232aConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Rs232a Interface Configuration table."
::= { trirs232a-card 1 }
trirs232aConfigEntry OBJECT-TYPE
SYNTAX TriRs232aConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 3Rs232a Configuration table."
INDEX { trirsCfgSlotIndex , trirsCfgPortIndex }
::= { trirs232aConfigTable 1 }
TriRs232aConfigEntry ::= SEQUENCE {
trirsCfgSlotIndex SmallSlotIndex,
trirsCfgPortIndex ThreePortID,
trirsCfgMux INTEGER,
trirsCfgSyncMode INTEGER,
trirsCfgRate INTEGER,
trirsCfgBitPos INTEGER,
trirsCfgClkPolarity INTEGER,
trirsCfgDataPolarity INTEGER,
trirsCfgRTS INTEGER,
trirsCfgTTM INTEGER,
trirsCfgDteDceMode INTEGER,
trirsCfgDtrSel INTEGER,
trirsCfgInterface INTEGER,
trirsCfgBitPos0Used INTEGER,
trirsCfgBitPos1Used INTEGER,
trirsCfgBitPos2Used INTEGER,
trirsCfgBitPos3Used INTEGER,
trirsCfgBitPos4Used INTEGER,
trirsCfgBitPos5Used INTEGER,
trirsCfgBitPos6Used INTEGER,
trirsCfgBitPos7Used INTEGER,
trirsCfgWarrning DisplayString
}
trirsCfgSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aConfigEntry 1 }
trirsCfgPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, Total 3 ports"
::= { trirs232aConfigEntry 2 }
trirsCfgMux OBJECT-TYPE
SYNTAX INTEGER {
nonMux(1),
mux(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a MUX mode"
::= { trirs232aConfigEntry 3 }
trirsCfgSyncMode OBJECT-TYPE
SYNTAX INTEGER {
async8(1),
async9(2),
async10(3),
async11(4),
async12(5),
sync(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Sync mode"
::= { trirs232aConfigEntry 4 }
trirsCfgRate OBJECT-TYPE
SYNTAX INTEGER {
r0-6K(1),
r1-2K(2),
r2-4K(3),
r4-8K(4),
r7-2K(5),
r9-6K(6),
r14-4K(7),
r19-2K(8),
r38-4K(9),
r48K(10),
r64K(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Base Rate"
::= { trirs232aConfigEntry 5 }
trirsCfgBitPos OBJECT-TYPE
SYNTAX INTEGER {
position-0(1),
position-1(2),
position-2(3),
position-3(4),
position-4(5),
position-5(6),
position-6(7),
position-7(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Bit position"
::= { trirs232aConfigEntry 6 }
trirsCfgClkPolarity OBJECT-TYPE
SYNTAX INTEGER {
clockNormal(1),
clockInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Clock Polarity"
::= { trirs232aConfigEntry 7 }
trirsCfgDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
dataNormal(1),
dataInverted(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Data Polarity"
::= { trirs232aConfigEntry 8 }
trirsCfgRTS OBJECT-TYPE
SYNTAX INTEGER {
rtsActive(1),
rtsPermanent(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a RTS Mode"
::= { trirs232aConfigEntry 9 }
trirsCfgTTM OBJECT-TYPE
SYNTAX INTEGER {
ttmOff(1),
ttmOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a TTM Mode"
::= { trirs232aConfigEntry 10 }
trirsCfgDteDceMode OBJECT-TYPE
SYNTAX INTEGER {
dte(1),
dce(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a DTE/DCE Mode"
::= { trirs232aConfigEntry 11 }
trirsCfgDtrSel OBJECT-TYPE
SYNTAX INTEGER {
dtrOff(1),
dtrOn(2),
na(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Dtr"
::= { trirs232aConfigEntry 12 }
trirsCfgInterface OBJECT-TYPE
SYNTAX INTEGER {
db44(1),
rj45(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Interface Type"
::= { trirs232aConfigEntry 13 }
trirsCfgBitPos0Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 0 Stream Position Used"
::= { trirs232aConfigEntry 14 }
trirsCfgBitPos1Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 1 Stream Position Used"
::= { trirs232aConfigEntry 15 }
trirsCfgBitPos2Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 2 Stream Position Used"
::= { trirs232aConfigEntry 16 }
trirsCfgBitPos3Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 3 Stream Position Used"
::= { trirs232aConfigEntry 17 }
trirsCfgBitPos4Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 4 Stream Position Used"
::= { trirs232aConfigEntry 18 }
trirsCfgBitPos5Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 5 Stream Position Used"
::= { trirs232aConfigEntry 19 }
trirsCfgBitPos6Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 6 Stream Position Used"
::= { trirs232aConfigEntry 20 }
trirsCfgBitPos7Used OBJECT-TYPE
SYNTAX INTEGER {
unused(1),
port1(2),
port2(3),
port3(4),
port4(5),
port5(6),
port6(7),
port7(8),
port8(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a Bits 7 Stream Position Used"
::= { trirs232aConfigEntry 21 }
trirsCfgWarrning OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..70) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a map setup warning"
::= { trirs232aConfigEntry 22 }
--
-- 3Rs232a Status
--
trirs232aStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The 3Rs232a Status table."
::= { trirs232a-card 2 }
trirs232aStatusEntry OBJECT-TYPE
SYNTAX TriRs232aStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 3Rs232a Status table."
INDEX { trirsStatusSlotIndex , trirsStatusPortIndex }
::= { trirs232aStatusTable 1 }
TriRs232aStatusEntry ::= SEQUENCE {
trirsStatusSlotIndex SmallSlotIndex,
trirsStatusPortIndex ThreePortID,
trirsStatusS1 INTEGER,
trirsStatusS3 INTEGER,
trirsStatusS4 INTEGER,
trirsStatusS6 INTEGER,
trirsStatusS8 INTEGER,
trirsStatusS9 INTEGER,
trirsStatusE4 INTEGER,
trirsStatusE5 INTEGER,
trirsStatusE6 INTEGER,
trirsStatusX INTEGER,
trirsStatusDteCTS INTEGER,
trirsStatusDteDCD INTEGER,
trirsStatusRTSloss INTEGER,
trirsStatusEXTCLKloss INTEGER,
trirsStatusDSRstatus INTEGER,
trirsStatusCTSstatus INTEGER,
trirsStatusDCDstatus INTEGER,
trirsStatusDTRstatus INTEGER,
trirsStatusRTSstatus INTEGER,
trirsStatusRemoteAlm INTEGER,
trirsStatusRemoteS1 INTEGER,
trirsStatusRemoteS3 INTEGER,
trirsStatusRemoteS4 INTEGER,
trirsStatusRemoteS6 INTEGER,
trirsStatusRemoteS8 INTEGER,
trirsStatusRemoteS9 INTEGER,
trirsStatusRemoteE4 INTEGER,
trirsStatusRemoteE5 INTEGER,
trirsStatusRemoteE6 INTEGER,
trirsStatusRemoteX INTEGER
}
trirsStatusSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aStatusEntry 1 }
trirsStatusPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, Total 3 ports"
::= { trirs232aStatusEntry 2 }
trirsStatusS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S1"
::= { trirs232aStatusEntry 3 }
trirsStatusS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S3"
::= { trirs232aStatusEntry 4 }
trirsStatusS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S4"
::= { trirs232aStatusEntry 5 }
trirsStatusS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S6"
::= { trirs232aStatusEntry 6 }
trirsStatusS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S8"
::= { trirs232aStatusEntry 7 }
trirsStatusS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
dtr(4),
dsr(5),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit S9"
::= { trirs232aStatusEntry 8 }
trirsStatusE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit E4"
::= { trirs232aStatusEntry 9 }
trirsStatusE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit E5"
::= { trirs232aStatusEntry 10 }
trirsStatusE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit E6"
::= { trirs232aStatusEntry 11 }
trirsStatusX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rtswithFrameSYNC(12),
frameSYNC(13),
na(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit X"
::= { trirs232aStatusEntry 12 }
trirsStatusDteCTS OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit DTE CTS"
::= { trirs232aStatusEntry 13 }
trirsStatusDteDCD OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
rts(3),
remote-S1(6),
remote-S3(7),
remote-S4(8),
remote-S6(9),
remote-S8(10),
remote-S9(11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Status bit DTE DCD"
::= { trirs232aStatusEntry 14 }
trirsStatusRTSloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a RTS loss"
::= { trirs232aStatusEntry 15 }
trirsStatusEXTCLKloss OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a EXT-CLK loss"
::= { trirs232aStatusEntry 16 }
trirsStatusDSRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a DSR"
::= { trirs232aStatusEntry 17 }
trirsStatusCTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a CTS"
::= { trirs232aStatusEntry 18 }
trirsStatusDCDstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a DCD"
::= { trirs232aStatusEntry 19 }
trirsStatusDTRstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a DTR"
::= { trirs232aStatusEntry 20 }
trirsStatusRTSstatus OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a RTS"
::= { trirs232aStatusEntry 21 }
trirsStatusRemoteAlm OBJECT-TYPE
SYNTAX INTEGER {
no(1),
yes(2),
na(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a RTS"
::= { trirs232aStatusEntry 22 }
trirsStatusRemoteS1 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S1"
::= { trirs232aStatusEntry 23 }
trirsStatusRemoteS3 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S3"
::= { trirs232aStatusEntry 24 }
trirsStatusRemoteS4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S4"
::= { trirs232aStatusEntry 25 }
trirsStatusRemoteS6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S6"
::= { trirs232aStatusEntry 26 }
trirsStatusRemoteS8 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S8"
::= { trirs232aStatusEntry 27 }
trirsStatusRemoteS9 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit S9"
::= { trirs232aStatusEntry 28 }
trirsStatusRemoteE4 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit E4"
::= { trirs232aStatusEntry 29 }
trirsStatusRemoteE5 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit E5"
::= { trirs232aStatusEntry 30 }
trirsStatusRemoteE6 OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit E6"
::= { trirs232aStatusEntry 31 }
trirsStatusRemoteX OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2),
na(14)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"3Rs232a remote status bit X"
::= { trirs232aStatusEntry 32 }
--
-- 3RS232a Alarm Control Table
--
trirs232aAlarmCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The 3rs232a alarm control table."
::= { trirs232a-card 3 }
trirs232aAlarmCtrlEntry OBJECT-TYPE
SYNTAX TriRs232aAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 3rs232a alarm control table."
INDEX { trirsAlarmSlotIndex , trirsAlarmPortIndex }
::= { trirs232aAlarmCtrlTable 1 }
TriRs232aAlarmCtrlEntry ::= SEQUENCE {
trirsAlarmSlotIndex SmallSlotIndex,
trirsAlarmPortIndex ThreePortID,
trirsAlarmSetup AlarmSeverity
}
trirsAlarmSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aAlarmCtrlEntry 1 }
trirsAlarmPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { trirs232aAlarmCtrlEntry 2 }
trirsAlarmSetup OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { trirs232aAlarmCtrlEntry 3 }
--
-- 3RS232a Alarm History Table
--
trirs232aAlmHisTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aAlmHisEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: 3rs232aAlmHisUnitIndex "
::= { trirs232a-card 4 }
trirs232aAlmHisEntry OBJECT-TYPE
SYNTAX TriRs232aAlmHisEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { trirsAlmHisSlotIndex , trirsAlmHisPortIndex }
::= { trirs232aAlmHisTable 1 }
TriRs232aAlmHisEntry ::= SEQUENCE {
trirsAlmHisSlotIndex SmallSlotIndex,
trirsAlmHisPortIndex ThreePortID,
trirsAlmHistoryState INTEGER,
trirsAlmHistoryCount Counter,
trirsAlmHistoryEnable AlarmSeverity
}
trirsAlmHisSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aAlmHisEntry 1 }
trirsAlmHisPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 6, Total 6 ports"
::= { trirs232aAlmHisEntry 2 }
trirsAlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { trirs232aAlmHisEntry 3 }
trirsAlmHistoryCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { trirs232aAlmHisEntry 4 }
trirsAlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { trirs232aAlmHisEntry 5 }
--
-- 3RS232a Diagnostic Control Table
--
trirs232aDiagCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { trirs232a-card 5 }
trirs232aDiagCtrlEntry OBJECT-TYPE
SYNTAX TriRs232aDiagCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { trirs232aDiagCtrlSlotIndex , trirs232aDiagCtrlPortIndex }
::= { trirs232aDiagCtrlTable 1 }
TriRs232aDiagCtrlEntry ::= SEQUENCE {
trirs232aDiagCtrlSlotIndex SmallSlotIndex,
trirs232aDiagCtrlPortIndex ThreePortID,
trirs232aNearLoopback INTEGER
}
trirs232aDiagCtrlSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aDiagCtrlEntry 1 }
trirs232aDiagCtrlPortIndex OBJECT-TYPE
SYNTAX ThreePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1 to 3, Total 3 ports"
::= { trirs232aDiagCtrlEntry 2 }
trirs232aNearLoopback OBJECT-TYPE
SYNTAX INTEGER {
noLoopback(1),
toDTE(2),
toLocal(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"3Rs232a Loopback Type"
::= { trirs232aDiagCtrlEntry 3 }
--
-- 3RS232a Card Control Table
--
trirs232aCardCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aCardCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The 3rs232a Card control table."
::= { trirs232a-card 6 }
trirs232aCardCtrlEntry OBJECT-TYPE
SYNTAX TriRs232aCardCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 3rs232a Card control table."
INDEX { trirs232aCardIndex }
::= { trirs232aCardCtrlTable 1 }
TriRs232aCardCtrlEntry ::= SEQUENCE {
trirs232aCardIndex SmallSlotIndex,
trirs232aReset INTEGER,
trirs232aLoadDefault INTEGER
}
trirs232aCardIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aCardCtrlEntry 1 }
trirs232aReset OBJECT-TYPE
SYNTAX INTEGER {
na(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset 3rs232a card"
::= { trirs232aCardCtrlEntry 2 }
trirs232aLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
na(1),
default(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Load default"
::= { trirs232aCardCtrlEntry 3 }
--
-- 3Rs232a System Information Table
--
trirs232aSysInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF TriRs232aSysInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The 3Rs232a system information table."
::= { trirs232a-card 7}
trirs232aSysInfoEntry OBJECT-TYPE
SYNTAX TriRs232aSysInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the 3Rs232a system information table."
INDEX { trirs232aSISlotIndex }
::= { trirs232aSysInfoTable 1 }
TriRs232aSysInfoEntry ::= SEQUENCE {
trirs232aSISlotIndex SmallSlotIndex,
trirs232aPROMVersion DisplayString,
trirs232aHardwareVersion DisplayString,
trirs232aFpgaVersion DisplayString,
trirs232aBank1Version DisplayString,
trirs232aBank2Version DisplayString,
trirs232aActiveBank INTEGER
}
trirs232aSISlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232aSysInfoEntry 1 }
trirs232aPROMVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" trirs232a PROM Version"
::= { trirs232aSysInfoEntry 2 }
trirs232aHardwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30) )
ACCESS read-only
STATUS mandatory
DESCRIPTION
" 3rs232a Hardware Version"
::= { trirs232aSysInfoEntry 3 }
trirs232aFpgaVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA Version"
::= { trirs232aSysInfoEntry 4 }
trirs232aBank1Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-1 Version"
::= { trirs232aSysInfoEntry 5 }
trirs232aBank2Version OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bank-2 Version"
::= { trirs232aSysInfoEntry 6}
trirs232aActiveBank OBJECT-TYPE
SYNTAX INTEGER{
bank-1(1),
bank-2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active Bank 1/2"
::= { trirs232aSysInfoEntry 7 }
--
-- 3RS232 Bert Control Table
--
trirs232BertCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Trirs232BertCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"3RS232 Bert Control Table."
::= { trirs232a-card 8 }
trirs232BertCtrlEntry OBJECT-TYPE
SYNTAX Trirs232BertCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of 3RS232 Bert control table."
INDEX { trirs232BertCtrlSlot , trirs232BertCtrlPort}
::= { trirs232BertCtrlTable 1 }
Trirs232BertCtrlEntry ::= SEQUENCE {
trirs232BertCtrlSlot SmallSlotIndex,
trirs232BertCtrlPort INTEGER,
trirs232BertCtrlType INTEGER,
-- trirs232BertCtrlPattern DisplayString,
trirs232BertCtrlPeriod INTEGER,
trirs232BertCtrlEnable INTEGER,
trirs232BertCtrlSync INTEGER,
trirs232BertCtrlError INTEGER,
trirs232BertCtrlTime INTEGER,
trirs232BertCtrlES INTEGER,
trirs232BertCtrlSES INTEGER,
trirs232BertCtrlUS INTEGER,
trirs232BertCtrlDirect INTEGER
}
trirs232BertCtrlSlot OBJECT-TYPE
SYNTAX SmallSlotIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot 1~12, total 12 slots."
::= { trirs232BertCtrlEntry 1 }
trirs232BertCtrlPort OBJECT-TYPE
SYNTAX ThreePortID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Port"
::= { trirs232BertCtrlEntry 2 }
trirs232BertCtrlType OBJECT-TYPE
SYNTAX INTEGER {
--off(1),
--prbs2exp20of1(2),
--prbs2exp15of1(3),
prbs2exp11of1(4),
prbs2exp9of1(5)
-- userDefine(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Type"
::= { trirs232BertCtrlEntry 3 }
-- trirs232BertCtrlPattern OBJECT-TYPE
-- SYNTAX DisplayString (SIZE (0..255))
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "Bert User Pattern"
-- ::= { trirs232BertCtrlEntry 4 }
trirs232BertCtrlPeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bert Spilt Mode"
::= { trirs232BertCtrlEntry 5 }
trirs232BertCtrlEnable OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
clear(3),
insertErr(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status"
::= { trirs232BertCtrlEntry 6 }
trirs232BertCtrlSync OBJECT-TYPE
SYNTAX INTEGER {
unsync(1),
sync(2),
na(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { trirs232BertCtrlEntry 7 }
trirs232BertCtrlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Count"
::= { trirs232BertCtrlEntry 8 }
trirs232BertCtrlTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert run time"
::= { trirs232BertCtrlEntry 9 }
trirs232BertCtrlES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Error Second"
::= { trirs232BertCtrlEntry 10 }
trirs232BertCtrlSES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert SES"
::= { trirs232BertCtrlEntry 11 }
trirs232BertCtrlUS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bert Unsync Second"
::= { trirs232BertCtrlEntry 12 }
trirs232BertCtrlDirect OBJECT-TYPE
SYNTAX INTEGER {
toNetwork(1),
toLine(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bert Direct"
::= { trirs232BertCtrlEntry 13 }
trirs232aTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of 3Rs232a"
::= { trirs232a-card 100 }
--============================================================================--
--======================================================================--
--======================================================================--
-- clka-card MIB
--======================================================================--
--======================================================================--
clkaConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clka Interface Configuration table."
::= { clka-card 1 }
clkaConfigEntry OBJECT-TYPE
SYNTAX ClkaConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the clka Configuration table."
INDEX { clkaCfgSlotIndex }
::= { clkaConfigTable 1 }
ClkaConfigEntry ::= SEQUENCE {
clkaCfgSlotIndex SmallSlotIndex,
port1ClkaType INTEGER,
port1ClkaImpedance INTEGER,
port2ClkaType INTEGER,
port2ClkaImpedance INTEGER
}
clkaCfgSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaConfigEntry 1 }
port1ClkaType OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
t1D4(2),
t1Esf(3),
e1Fas(4),
e1Crc4(5),
ext2048Khz(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clka port 1 type"
::= { clkaConfigEntry 2 }
port1ClkaImpedance OBJECT-TYPE
SYNTAX INTEGER {
ohm75(1),
ohm120(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clka port 1 impedance"
::= { clkaConfigEntry 3 }
port2ClkaType OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
t1D4(2),
t1Esf(3),
e1Fas(4),
e1Crc4(5),
ext2048Khz(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clka port 2 type"
::= { clkaConfigEntry 4 }
port2ClkaImpedance OBJECT-TYPE
SYNTAX INTEGER {
ohm75(1),
ohm120(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"clka port 2 impedance"
::= { clkaConfigEntry 5 }
clkaCommandControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { clka-card 2 }
clkaCommandControlEntry OBJECT-TYPE
SYNTAX ClkaCommandControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { clkaCommandControlIndex }
::= { clkaCommandControlTable 1 }
ClkaCommandControlEntry ::= SEQUENCE {
clkaCommandControlIndex SmallSlotIndex,
clkaCommandControlLoadDefault INTEGER
}
clkaCommandControlIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaCommandControlEntry 1 }
clkaCommandControlLoadDefault OBJECT-TYPE
SYNTAX INTEGER {
load-default(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Command: Load Default CLKA CONF"
::= { clkaCommandControlEntry 2 }
clkaStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The command control table."
::= { clka-card 3 }
clkaStatusEntry OBJECT-TYPE
SYNTAX ClkaStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the command control table."
INDEX { clkaStatusSlotIndex }
::= { clkaStatusTable 1 }
ClkaStatusEntry ::= SEQUENCE {
clkaStatusSlotIndex SmallSlotIndex,
clkaP1Status INTEGER,
clkaP2Status INTEGER,
clkaAlarmInStatus INTEGER
}
clkaStatusSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaStatusEntry 1 }
clkaP1Status OBJECT-TYPE
SYNTAX INTEGER {
los(1),
lof(2),
ais(3),
sync(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"clka port 1 status"
::= { clkaStatusEntry 2 }
clkaP2Status OBJECT-TYPE
SYNTAX INTEGER {
los(1),
lof(2),
ais(3),
sync(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"clka port 2 status"
::= { clkaStatusEntry 3 }
clkaAlarmInStatus OBJECT-TYPE
SYNTAX INTEGER {
alarm(1),
normal(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"clka alarm input status"
::= { clkaStatusEntry 4 }
--
-- CLKa Alarm Control Table
--
clkaAlarmCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clka alarm control table."
::= { clka-card 4 }
clkaAlarmCtrlEntry OBJECT-TYPE
SYNTAX ClkaAlarmCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the clka alarm control table."
INDEX { clkaAlarmSlotIndex , clkaAlarmPortIndex }
::= { clkaAlarmCtrlTable 1 }
ClkaAlarmCtrlEntry ::= SEQUENCE {
clkaAlarmSlotIndex SmallSlotIndex,
clkaAlarmPortIndex OnePortID,
clkaAlarmAlarmIn AlarmSeverity
}
clkaAlarmSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaAlarmCtrlEntry 1 }
clkaAlarmPortIndex OBJECT-TYPE
SYNTAX OnePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1"
::= { clkaAlarmCtrlEntry 2 }
clkaAlarmAlarmIn OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm-in is enabled or not"
::= { clkaAlarmCtrlEntry 3 }
--
-- CLKa Alarm History Table
--
clkaAlmHisTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaAlmHisEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Key: clkaAlmHisUnitIndex "
::= { clka-card 5 }
clkaAlmHisEntry OBJECT-TYPE
SYNTAX ClkaAlmHisEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { clkaAlmHisSlotIndex , clkaAlmHisPortIndex }
::= { clkaAlmHisTable 1 }
ClkaAlmHisEntry ::= SEQUENCE {
clkaAlmHisSlotIndex SmallSlotIndex,
clkaAlmHisPortIndex OnePortID,
clkaAlmHistoryState INTEGER,
clkaAlmHistoryCount Counter,
clkaAlmHistoryEnable AlarmSeverity
}
clkaAlmHisSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaAlmHisEntry 1 }
clkaAlmHisPortIndex OBJECT-TYPE
SYNTAX OnePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port "
::= { clkaAlmHisEntry 2 }
clkaAlmHistoryState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
alarm(2),
disable(3),
na(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Current State"
::= { clkaAlmHisEntry 3 }
clkaAlmHistoryCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Alarm Count which happened "
::= { clkaAlmHisEntry 4 }
clkaAlmHistoryEnable OBJECT-TYPE
SYNTAX AlarmSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm is enabled or not"
::= { clkaAlmHisEntry 5 }
--
-- Alarm Queue Table
--
clkaAlmQueueTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClkaAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"clka Alm Queue Table"
::= { clka-card 6 }
clkaAlmQueueEntry OBJECT-TYPE
SYNTAX ClkaAlmQueueEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" "
INDEX { clkaAlmQueueSlotIndex ,
clkaAlmQueuePortIndex ,
clkaAlmQueueNumber }
::= { clkaAlmQueueTable 1 }
ClkaAlmQueueEntry ::= SEQUENCE {
clkaAlmQueueSlotIndex SmallSlotIndex,
clkaAlmQueuePortIndex OnePortID,
clkaAlmQueueNumber INTEGER (1..40),
clkaAlmQueueString DisplayString (SIZE(0..80))
}
clkaAlmQueueSlotIndex OBJECT-TYPE
SYNTAX SmallSlotIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot A~D, total 4 slots."
::= { clkaAlmQueueEntry 1 }
clkaAlmQueuePortIndex OBJECT-TYPE
SYNTAX OnePortID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1"
::= { clkaAlmQueueEntry 2 }
clkaAlmQueueNumber OBJECT-TYPE
SYNTAX INTEGER (1..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Select Latest Alarm Queue number (1-40)"
::= { clkaAlmQueueEntry 3 }
clkaAlmQueueString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm Queue String"
::= { clkaAlmQueueEntry 4 }
clkaTotalCard OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total cards of CLKa"
::= { clka-card 100 }
END