NBS-ODSYS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
|
|
nbs, NbsTcTemperature, NbsTcMilliVolt, NbsTcMilliAmp,
|
|
NbsTcStatusSimple, NbsTcStatusLevel, NbsTcPartIndex
|
|
FROM NBS-MIB
|
|
;
|
|
|
|
nbsOdsysMib MODULE-IDENTITY
|
|
LAST-UPDATED "201308200000Z" -- Aug 20, 2013
|
|
ORGANIZATION "NBS"
|
|
CONTACT-INFO
|
|
"For technical support, please contact your service channel"
|
|
DESCRIPTION
|
|
"For managing Opti-Driver systems."
|
|
::= { nbs 228 }
|
|
|
|
|
|
|
|
|
|
-- *******************************************************************
|
|
-- Groups in NBS-ODSYS-MIB
|
|
-- *******************************************************************
|
|
|
|
nbsOdsysChasGrp
|
|
OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis component overview"
|
|
::= { nbsOdsysMib 2 }
|
|
|
|
nbsOdsysCcGrp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis control card information"
|
|
::= { nbsOdsysMib 3 }
|
|
|
|
nbsOdsysFtGrp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis cooling system"
|
|
::= { nbsOdsysMib 4 }
|
|
|
|
nbsOdsysPsGrp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis power supplies"
|
|
::= { nbsOdsysMib 5 }
|
|
|
|
|
|
nbsOdsysEventsGrp OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { nbsOdsysMib 100 }
|
|
|
|
nbsOdsysEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Event NOTIFICATIONS"
|
|
::= { nbsOdsysEventsGrp 0 }
|
|
|
|
|
|
|
|
|
|
-- ********************************************************************
|
|
--
|
|
-- Objects for the nbsOdsysChasGrp group
|
|
--
|
|
-- ********************************************************************
|
|
|
|
nbsOdsysChasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NbsOdsysChasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { nbsOdsysChasGrp 1 }
|
|
|
|
nbsOdsysChasEntry OBJECT-TYPE
|
|
SYNTAX NbsOdsysChasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about a particular OptiDriver chassis."
|
|
INDEX { nbsOdsysChasIndex }
|
|
::= { nbsOdsysChasTable 1 }
|
|
|
|
NbsOdsysChasEntry ::= SEQUENCE {
|
|
nbsOdsysChasIndex INTEGER,
|
|
nbsOdsysChasCcMaxCount INTEGER,
|
|
nbsOdsysChasPsMaxCount INTEGER,
|
|
nbsOdsysChasFtMaxCount INTEGER
|
|
}
|
|
|
|
nbsOdsysChasIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsCmmcChassisIndex of this chassis"
|
|
::= { nbsOdsysChasEntry 1 }
|
|
|
|
nbsOdsysChasCcMaxCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of control cards that can be installed in this chassis"
|
|
::= { nbsOdsysChasEntry 10 }
|
|
|
|
nbsOdsysChasPsMaxCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of power supply bays/slots in this chassis"
|
|
::= { nbsOdsysChasEntry 20 }
|
|
|
|
nbsOdsysChasFtMaxCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of fan tray bays/slots in this chassis"
|
|
::= { nbsOdsysChasEntry 30 }
|
|
|
|
|
|
|
|
-- ********************************************************************
|
|
--
|
|
-- Objects for the nbsOdsysCcGrp group
|
|
--
|
|
-- ********************************************************************
|
|
|
|
nbsOdsysCcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NbsOdsysCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about OptiDriver chassis control/fpga cards"
|
|
::= { nbsOdsysCcGrp 1 }
|
|
|
|
nbsOdsysCcEntry OBJECT-TYPE
|
|
SYNTAX NbsOdsysCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status information for a particular control card slot/bay.
|
|
When a control card is present, it will also have entries
|
|
in nbsPartHardTable, nbsPartFirmTable, and nbsPartProgTable.
|
|
|
|
The events nbsOdsysTrapCcFailed, nbsOdsysTrapCcRestored,
|
|
nbsOdsysTrapCcRemoved and nbsOdsysTrapCcInserted indicate
|
|
changes in nbsOdsysCcOperationalStatus."
|
|
INDEX { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
|
|
::= { nbsOdsysCcTable 1 }
|
|
|
|
NbsOdsysCcEntry ::= SEQUENCE {
|
|
nbsOdsysCcChasIndex INTEGER,
|
|
nbsOdsysCcBayIndex INTEGER,
|
|
nbsOdsysCcChIfIndex InterfaceIndex,
|
|
nbsOdsysCcPartIndex NbsTcPartIndex,
|
|
nbsOdsysCcThermActual NbsTcTemperature,
|
|
nbsOdsysCcThermLevel NbsTcStatusLevel,
|
|
nbsOdsysCcThermThreshLoErr NbsTcTemperature,
|
|
nbsOdsysCcThermThreshLoWarn NbsTcTemperature,
|
|
nbsOdsysCcThermThreshHiWarn NbsTcTemperature,
|
|
nbsOdsysCcThermThreshHiErr NbsTcTemperature,
|
|
nbsOdsysCcOperationalStatus NbsTcStatusSimple
|
|
}
|
|
|
|
nbsOdsysCcChasIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsCmmcChassisIndex of this control card's chassis"
|
|
::= { nbsOdsysCcEntry 1 }
|
|
|
|
nbsOdsysCcBayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The control card slot/bay #"
|
|
::= { nbsOdsysCcEntry 2 }
|
|
|
|
nbsOdsysCcChIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardIfIndex of this Cc daughtercard's chassis"
|
|
::= { nbsOdsysCcEntry 10 }
|
|
|
|
nbsOdsysCcPartIndex OBJECT-TYPE
|
|
SYNTAX NbsTcPartIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardPartIndex of this Cc daughtercard"
|
|
::= { nbsOdsysCcEntry 11 }
|
|
|
|
nbsOdsysCcThermActual OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current temperature reading,
|
|
in degrees celsius"
|
|
::= { nbsOdsysCcEntry 30}
|
|
|
|
nbsOdsysCcThermLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of current temperature reading with respect
|
|
to the CcTherm threshold objects below"
|
|
::= { nbsOdsysCcEntry 40 }
|
|
|
|
nbsOdsysCcThermThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysCcEntry 41 }
|
|
|
|
nbsOdsysCcThermThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysCcEntry 42 }
|
|
|
|
nbsOdsysCcThermThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysCcEntry 43 }
|
|
|
|
nbsOdsysCcThermThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysCcEntry 44 }
|
|
|
|
nbsOdsysCcOperationalStatus OBJECT-TYPE
|
|
SYNTAX NbsTcStatusSimple
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operational status of this daughtercard"
|
|
::= { nbsOdsysCcEntry 50 }
|
|
|
|
|
|
|
|
-- ********************************************************************
|
|
--
|
|
-- Objects for the nbsOdsysFtGrp group
|
|
--
|
|
-- ********************************************************************
|
|
|
|
nbsOdsysFtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NbsOdsysFtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { nbsOdsysFtGrp 1 }
|
|
|
|
nbsOdsysFtEntry OBJECT-TYPE
|
|
SYNTAX NbsOdsysFtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular chassis cooling assembly slot/bay.
|
|
|
|
Each installed fan tray also has entries in nbsPartHardTable.
|
|
|
|
The events nbsCmmcTrapFanFailure, nbsCmmcTrapFanRestored,
|
|
nbsCmmcTrapFanRemoved and nbsCmmcTrapFanInserted indicate
|
|
changes in nbsOdsysFtOperationalStatus."
|
|
INDEX { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex }
|
|
::= { nbsOdsysFtTable 1 }
|
|
|
|
NbsOdsysFtEntry ::= SEQUENCE {
|
|
nbsOdsysFtChasIndex INTEGER,
|
|
nbsOdsysFtBayIndex INTEGER,
|
|
nbsOdsysFtOperationalStatus NbsTcStatusSimple,
|
|
nbsOdsysFtChIfIndex InterfaceIndex,
|
|
nbsOdsysFtPartIndex NbsTcPartIndex,
|
|
nbsOdsysFtFanCount INTEGER,
|
|
nbsOdsysFtThermActual NbsTcTemperature,
|
|
nbsOdsysFtThermLevel NbsTcStatusLevel,
|
|
nbsOdsysFtThermThreshLoErr NbsTcTemperature,
|
|
nbsOdsysFtThermThreshLoWarn NbsTcTemperature,
|
|
nbsOdsysFtThermThreshHiWarn NbsTcTemperature,
|
|
nbsOdsysFtThermThreshHiErr NbsTcTemperature
|
|
}
|
|
|
|
nbsOdsysFtChasIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"nbsCmmcChassisIndex of this fan tray's chassis"
|
|
::= { nbsOdsysFtEntry 1 }
|
|
|
|
nbsOdsysFtBayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan tray bay/slot number, unique within this chassis"
|
|
::= { nbsOdsysFtEntry 2 }
|
|
|
|
nbsOdsysFtOperationalStatus OBJECT-TYPE
|
|
SYNTAX NbsTcStatusSimple
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value notSupported(1) indicates the fan tray is absent."
|
|
::= { nbsOdsysFtEntry 3 }
|
|
|
|
nbsOdsysFtChIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardIfIndex of this fan tray's chassis"
|
|
::= { nbsOdsysFtEntry 10 }
|
|
|
|
nbsOdsysFtPartIndex OBJECT-TYPE
|
|
SYNTAX NbsTcPartIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardPartIndex of this fan tray"
|
|
::= { nbsOdsysFtEntry 11 }
|
|
|
|
nbsOdsysFtFanCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of fans in this tray"
|
|
::= { nbsOdsysFtEntry 20 }
|
|
|
|
nbsOdsysFtThermActual OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current temperature reading,
|
|
in degrees celsius"
|
|
::= { nbsOdsysFtEntry 30}
|
|
|
|
nbsOdsysFtThermLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of current temperature reading with respect
|
|
to the FtTherm threshold objects below"
|
|
::= { nbsOdsysFtEntry 40 }
|
|
|
|
nbsOdsysFtThermThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysFtEntry 41 }
|
|
|
|
nbsOdsysFtThermThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysFtEntry 42 }
|
|
|
|
nbsOdsysFtThermThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysFtEntry 43 }
|
|
|
|
nbsOdsysFtThermThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysFtEntry 44 }
|
|
|
|
|
|
|
|
-- ********************************************************************
|
|
--
|
|
-- Objects for the nbsOdsysPsGrp group
|
|
--
|
|
-- ********************************************************************
|
|
|
|
--
|
|
-- PSTable (Power Supply Info)
|
|
--
|
|
|
|
nbsOdsysPsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NbsOdsysPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about OptiDriver chassis' power supplies"
|
|
::= { nbsOdsysPsGrp 2 }
|
|
|
|
nbsOdsysPsEntry OBJECT-TYPE
|
|
SYNTAX NbsOdsysPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular power supply slot/bay.
|
|
|
|
Each installed power supply also has entries in
|
|
nbsPartHardTable.
|
|
|
|
The events nbsCmmcTrapPowerSupplyFailure,
|
|
nbsCmmcTrapPowerSupplyRestored, nbsCmmcTrapPowerSupplyRemoved,
|
|
and nbsCmmcTrapPowerSupplyInserted indicate changes in
|
|
nbsOdsysFtOperationalStatus."
|
|
INDEX { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex }
|
|
::= { nbsOdsysPsTable 1 }
|
|
|
|
NbsOdsysPsEntry ::= SEQUENCE {
|
|
nbsOdsysPsChasIndex INTEGER,
|
|
nbsOdsysPsBayIndex INTEGER,
|
|
nbsOdsysPsOperationalStatus NbsTcStatusSimple,
|
|
nbsOdsysPsChIfIndex InterfaceIndex,
|
|
nbsOdsysPsPartIndex NbsTcPartIndex,
|
|
nbsOdsysPsFanCount INTEGER,
|
|
nbsOdsysPsThermActual NbsTcTemperature,
|
|
nbsOdsysPsThermLevel NbsTcStatusLevel,
|
|
nbsOdsysPsThermThreshLoErr NbsTcTemperature,
|
|
nbsOdsysPsThermThreshLoWarn NbsTcTemperature,
|
|
nbsOdsysPsThermThreshHiWarn NbsTcTemperature,
|
|
nbsOdsysPsThermThreshHiErr NbsTcTemperature,
|
|
nbsOdsysPsVInActual NbsTcMilliVolt,
|
|
nbsOdsysPsVInLevel NbsTcStatusLevel,
|
|
nbsOdsysPsVInThreshLoErr NbsTcMilliVolt,
|
|
nbsOdsysPsVInThreshLoWarn NbsTcMilliVolt,
|
|
nbsOdsysPsVInThreshHiWarn NbsTcMilliVolt,
|
|
nbsOdsysPsVInThreshHiErr NbsTcMilliVolt,
|
|
nbsOdsysPsVOutActual NbsTcMilliVolt,
|
|
nbsOdsysPsVOutLevel NbsTcStatusLevel,
|
|
nbsOdsysPsVOutThreshLoErr NbsTcMilliVolt,
|
|
nbsOdsysPsVOutThreshLoWarn NbsTcMilliVolt,
|
|
nbsOdsysPsVOutThreshHiWarn NbsTcMilliVolt,
|
|
nbsOdsysPsVOutThreshHiErr NbsTcMilliVolt,
|
|
nbsOdsysPsIInActual NbsTcMilliAmp,
|
|
nbsOdsysPsIInLevel NbsTcStatusLevel,
|
|
nbsOdsysPsIInThreshLoErr NbsTcMilliAmp,
|
|
nbsOdsysPsIInThreshLoWarn NbsTcMilliAmp,
|
|
nbsOdsysPsIInThreshHiWarn NbsTcMilliAmp,
|
|
nbsOdsysPsIInThreshHiErr NbsTcMilliAmp,
|
|
nbsOdsysPsIOutActual NbsTcMilliAmp,
|
|
nbsOdsysPsIOutLevel NbsTcStatusLevel,
|
|
nbsOdsysPsIOutThreshLoErr NbsTcMilliAmp,
|
|
nbsOdsysPsIOutThreshLoWarn NbsTcMilliAmp,
|
|
nbsOdsysPsIOutThreshHiWarn NbsTcMilliAmp,
|
|
nbsOdsysPsIOutThreshHiErr NbsTcMilliAmp
|
|
}
|
|
|
|
nbsOdsysPsChasIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsCmmcChassisIndex of this power supply's chassis"
|
|
::= { nbsOdsysPsEntry 1 }
|
|
|
|
nbsOdsysPsBayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of this power supply slot/bay"
|
|
::= { nbsOdsysPsEntry 2 }
|
|
|
|
nbsOdsysPsOperationalStatus OBJECT-TYPE
|
|
SYNTAX NbsTcStatusSimple
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value notSupported(1) indicates power supply is absent."
|
|
::= { nbsOdsysPsEntry 3 }
|
|
|
|
nbsOdsysPsChIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardIfIndex of this power supply's chassis"
|
|
::= { nbsOdsysPsEntry 10 }
|
|
|
|
nbsOdsysPsPartIndex OBJECT-TYPE
|
|
SYNTAX NbsTcPartIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nbsPartHardPartIndex of this power supply"
|
|
::= { nbsOdsysPsEntry 11 }
|
|
|
|
nbsOdsysPsFanCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates how many internal fans this power supply has."
|
|
::= { nbsOdsysPsEntry 30 }
|
|
|
|
nbsOdsysPsThermActual OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current temperature reading,
|
|
in degrees celsius"
|
|
::= { nbsOdsysPsEntry 40}
|
|
|
|
nbsOdsysPsThermLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of current temperature reading with respect
|
|
to the PsTherm threshold objects below"
|
|
::= { nbsOdsysPsEntry 41 }
|
|
|
|
nbsOdsysPsThermThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysPsEntry 42 }
|
|
|
|
nbsOdsysPsThermThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysPsEntry 43 }
|
|
|
|
nbsOdsysPsThermThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysPsEntry 44 }
|
|
|
|
nbsOdsysPsThermThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional operating temperature,
|
|
in degrees celsius"
|
|
::= { nbsOdsysPsEntry 45 }
|
|
|
|
nbsOdsysPsVInActual OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the input voltage reading, in millivolts"
|
|
::= { nbsOdsysPsEntry 50}
|
|
|
|
nbsOdsysPsVInLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of input voltage reading with respect
|
|
to the PsVIn threshold objects below"
|
|
::= { nbsOdsysPsEntry 51 }
|
|
|
|
nbsOdsysPsVInThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional input voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 52 }
|
|
|
|
nbsOdsysPsVInThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe input voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 53 }
|
|
|
|
nbsOdsysPsVInThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe input voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 54 }
|
|
|
|
nbsOdsysPsVInThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional input voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 55 }
|
|
|
|
nbsOdsysPsVOutActual OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the output voltage reading, in millivolts"
|
|
::= { nbsOdsysPsEntry 60}
|
|
|
|
nbsOdsysPsVOutLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of output voltage reading with respect
|
|
to the PsVOut threshold objects below"
|
|
::= { nbsOdsysPsEntry 61 }
|
|
|
|
nbsOdsysPsVOutThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional output voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 62}
|
|
|
|
nbsOdsysPsVOutThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe output voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 63 }
|
|
|
|
nbsOdsysPsVOutThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe output voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 64 }
|
|
|
|
nbsOdsysPsVOutThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliVolt
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional output voltage, in millivolts"
|
|
::= { nbsOdsysPsEntry 65 }
|
|
|
|
nbsOdsysPsIInActual OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the input current reading, in milliamps"
|
|
::= { nbsOdsysPsEntry 70}
|
|
|
|
nbsOdsysPsIInLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of input current reading with respect
|
|
to the PsIIn threshold objects below"
|
|
::= { nbsOdsysPsEntry 71 }
|
|
|
|
nbsOdsysPsIInThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional input current, in milliamps"
|
|
::= { nbsOdsysPsEntry 72 }
|
|
|
|
nbsOdsysPsIInThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe input current, in milliamps"
|
|
::= { nbsOdsysPsEntry 73 }
|
|
|
|
nbsOdsysPsIInThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe input current, in milliamps"
|
|
::= { nbsOdsysPsEntry 74 }
|
|
|
|
nbsOdsysPsIInThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional input current, in milliamps"
|
|
::= { nbsOdsysPsEntry 75 }
|
|
|
|
nbsOdsysPsIOutActual OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the output current, in milliamps"
|
|
::= { nbsOdsysPsEntry 80}
|
|
|
|
nbsOdsysPsIOutLevel OBJECT-TYPE
|
|
SYNTAX NbsTcStatusLevel
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates level of output current reading with respect
|
|
to the PsIOut threshold objects below"
|
|
::= { nbsOdsysPsEntry 81 }
|
|
|
|
nbsOdsysPsIOutThreshLoErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum functional output current, in milliamps"
|
|
::= { nbsOdsysPsEntry 82 }
|
|
|
|
nbsOdsysPsIOutThreshLoWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the minimum safe output current, in milliamps"
|
|
::= { nbsOdsysPsEntry 83 }
|
|
|
|
nbsOdsysPsIOutThreshHiWarn OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum safe output current, in milliamps"
|
|
::= { nbsOdsysPsEntry 84 }
|
|
|
|
nbsOdsysPsIOutThreshHiErr OBJECT-TYPE
|
|
SYNTAX NbsTcMilliAmp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maximum functional output current, in milliamps"
|
|
::= { nbsOdsysPsEntry 85 }
|
|
|
|
|
|
|
|
|
|
-- ********************************************************************
|
|
--
|
|
-- Notifications in nbsOdsysEvents
|
|
--
|
|
-- ********************************************************************
|
|
|
|
|
|
nbsOdsysTrapCcThermLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex,
|
|
nbsOdsysCcThermActual, nbsOdsysCcThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when nbsOdsysCcThermLevel changes to anything but
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 30 }
|
|
|
|
nbsOdsysTrapCcThermLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex,
|
|
nbsOdsysCcThermActual, nbsOdsysCcThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when nbsOdsysCcThermLevel changes to statusGood (4)"
|
|
::= { nbsOdsysEvents 31 }
|
|
|
|
nbsOdsysTrapFtThermLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex,
|
|
nbsOdsysFtThermActual, nbsOdsysFtThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when fan tray's nbsOdsysFtThermLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 40 }
|
|
|
|
nbsOdsysTrapFtThermLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex,
|
|
nbsOdsysFtThermActual, nbsOdsysFtThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when fan tray's nbsOdsysFtThermLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 41 }
|
|
|
|
nbsOdsysTrapPsThermLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsThermActual, nbsOdsysPsThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsThermLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 50 }
|
|
|
|
nbsOdsysTrapPsThermLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsThermActual, nbsOdsysPsThermLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsThermLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 51 }
|
|
|
|
nbsOdsysTrapPsVInLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsVInActual, nbsOdsysPsVInLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsVInLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 60 }
|
|
|
|
nbsOdsysTrapPsVInLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsVInActual, nbsOdsysPsVInLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsVInLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 61 }
|
|
|
|
nbsOdsysTrapPsVOutLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsVOutActual, nbsOdsysPsVOutLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsVOutLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 70 }
|
|
|
|
nbsOdsysTrapPsVOutLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsVOutActual, nbsOdsysPsVOutLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsVOutLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 71 }
|
|
|
|
nbsOdsysTrapPsIInLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsIInActual, nbsOdsysPsIInLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsIInLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 80 }
|
|
|
|
nbsOdsysTrapPsIInLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsIInActual, nbsOdsysPsIInLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsIInLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 81 }
|
|
|
|
nbsOdsysTrapPsIOutLevelBad NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsIOutActual, nbsOdsysPsIOutLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsIOutLevel changes to
|
|
anything but statusGood (4)"
|
|
::= { nbsOdsysEvents 90 }
|
|
|
|
nbsOdsysTrapPsIOutLevelOk NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
|
|
nbsOdsysPsIOutActual, nbsOdsysPsIOutLevel }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sent when power supply's nbsOdsysPsIOutLevel changes to
|
|
statusGood (4)"
|
|
::= { nbsOdsysEvents 91 }
|
|
|
|
nbsOdsysTrapCcFailed NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Triggered when nbsOdsysCcOperationalStatus transitions to
|
|
bad (2)"
|
|
::= { nbsOdsysEvents 131 }
|
|
|
|
nbsOdsysTrapCcRestored NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Triggered when nbsOdsysCcOperationalStatus transitions to
|
|
good (3)"
|
|
::= { nbsOdsysEvents 132 }
|
|
|
|
nbsOdsysTrapCcRemoved NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Triggered when control card is removed from chassis"
|
|
::= { nbsOdsysEvents 133 }
|
|
|
|
nbsOdsysTrapCcInserted NOTIFICATION-TYPE
|
|
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Triggered when control card is inserted into chassis"
|
|
::= { nbsOdsysEvents 134 }
|
|
|
|
END
|