NBS-ODSYS-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
nbs, NbsTcTemperature, NbsTcMilliVolt, NbsTcMilliAmp,
NbsTcStatusSimple, NbsTcStatusLevel, NbsTcPartIndex
FROM NBS-MIB
;
nbsOdsysMib MODULE-IDENTITY
LAST-UPDATED "201308200000Z" -- Aug 20, 2013
ORGANIZATION "NBS"
CONTACT-INFO
"For technical support, please contact your service channel"
DESCRIPTION
"For managing Opti-Driver systems."
::= { nbs 228 }
-- *******************************************************************
-- Groups in NBS-ODSYS-MIB
-- *******************************************************************
nbsOdsysChasGrp
OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chassis component overview"
::= { nbsOdsysMib 2 }
nbsOdsysCcGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chassis control card information"
::= { nbsOdsysMib 3 }
nbsOdsysFtGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chassis cooling system"
::= { nbsOdsysMib 4 }
nbsOdsysPsGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Chassis power supplies"
::= { nbsOdsysMib 5 }
nbsOdsysEventsGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
""
::= { nbsOdsysMib 100 }
nbsOdsysEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Event NOTIFICATIONS"
::= { nbsOdsysEventsGrp 0 }
-- ********************************************************************
--
-- Objects for the nbsOdsysChasGrp group
--
-- ********************************************************************
nbsOdsysChasTable OBJECT-TYPE
SYNTAX SEQUENCE OF NbsOdsysChasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { nbsOdsysChasGrp 1 }
nbsOdsysChasEntry OBJECT-TYPE
SYNTAX NbsOdsysChasEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular OptiDriver chassis."
INDEX { nbsOdsysChasIndex }
::= { nbsOdsysChasTable 1 }
NbsOdsysChasEntry ::= SEQUENCE {
nbsOdsysChasIndex INTEGER,
nbsOdsysChasCcMaxCount INTEGER,
nbsOdsysChasPsMaxCount INTEGER,
nbsOdsysChasFtMaxCount INTEGER
}
nbsOdsysChasIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsCmmcChassisIndex of this chassis"
::= { nbsOdsysChasEntry 1 }
nbsOdsysChasCcMaxCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of control cards that can be installed in this chassis"
::= { nbsOdsysChasEntry 10 }
nbsOdsysChasPsMaxCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power supply bays/slots in this chassis"
::= { nbsOdsysChasEntry 20 }
nbsOdsysChasFtMaxCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of fan tray bays/slots in this chassis"
::= { nbsOdsysChasEntry 30 }
-- ********************************************************************
--
-- Objects for the nbsOdsysCcGrp group
--
-- ********************************************************************
nbsOdsysCcTable OBJECT-TYPE
SYNTAX SEQUENCE OF NbsOdsysCcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about OptiDriver chassis control/fpga cards"
::= { nbsOdsysCcGrp 1 }
nbsOdsysCcEntry OBJECT-TYPE
SYNTAX NbsOdsysCcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status information for a particular control card slot/bay.
When a control card is present, it will also have entries
in nbsPartHardTable, nbsPartFirmTable, and nbsPartProgTable.
The events nbsOdsysTrapCcFailed, nbsOdsysTrapCcRestored,
nbsOdsysTrapCcRemoved and nbsOdsysTrapCcInserted indicate
changes in nbsOdsysCcOperationalStatus."
INDEX { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
::= { nbsOdsysCcTable 1 }
NbsOdsysCcEntry ::= SEQUENCE {
nbsOdsysCcChasIndex INTEGER,
nbsOdsysCcBayIndex INTEGER,
nbsOdsysCcChIfIndex InterfaceIndex,
nbsOdsysCcPartIndex NbsTcPartIndex,
nbsOdsysCcThermActual NbsTcTemperature,
nbsOdsysCcThermLevel NbsTcStatusLevel,
nbsOdsysCcThermThreshLoErr NbsTcTemperature,
nbsOdsysCcThermThreshLoWarn NbsTcTemperature,
nbsOdsysCcThermThreshHiWarn NbsTcTemperature,
nbsOdsysCcThermThreshHiErr NbsTcTemperature,
nbsOdsysCcOperationalStatus NbsTcStatusSimple
}
nbsOdsysCcChasIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsCmmcChassisIndex of this control card's chassis"
::= { nbsOdsysCcEntry 1 }
nbsOdsysCcBayIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The control card slot/bay #"
::= { nbsOdsysCcEntry 2 }
nbsOdsysCcChIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardIfIndex of this Cc daughtercard's chassis"
::= { nbsOdsysCcEntry 10 }
nbsOdsysCcPartIndex OBJECT-TYPE
SYNTAX NbsTcPartIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardPartIndex of this Cc daughtercard"
::= { nbsOdsysCcEntry 11 }
nbsOdsysCcThermActual OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current temperature reading,
in degrees celsius"
::= { nbsOdsysCcEntry 30}
nbsOdsysCcThermLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of current temperature reading with respect
to the CcTherm threshold objects below"
::= { nbsOdsysCcEntry 40 }
nbsOdsysCcThermThreshLoErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional operating temperature,
in degrees celsius"
::= { nbsOdsysCcEntry 41 }
nbsOdsysCcThermThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe operating temperature,
in degrees celsius"
::= { nbsOdsysCcEntry 42 }
nbsOdsysCcThermThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe operating temperature,
in degrees celsius"
::= { nbsOdsysCcEntry 43 }
nbsOdsysCcThermThreshHiErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional operating temperature,
in degrees celsius"
::= { nbsOdsysCcEntry 44 }
nbsOdsysCcOperationalStatus OBJECT-TYPE
SYNTAX NbsTcStatusSimple
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Operational status of this daughtercard"
::= { nbsOdsysCcEntry 50 }
-- ********************************************************************
--
-- Objects for the nbsOdsysFtGrp group
--
-- ********************************************************************
nbsOdsysFtTable OBJECT-TYPE
SYNTAX SEQUENCE OF NbsOdsysFtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { nbsOdsysFtGrp 1 }
nbsOdsysFtEntry OBJECT-TYPE
SYNTAX NbsOdsysFtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular chassis cooling assembly slot/bay.
Each installed fan tray also has entries in nbsPartHardTable.
The events nbsCmmcTrapFanFailure, nbsCmmcTrapFanRestored,
nbsCmmcTrapFanRemoved and nbsCmmcTrapFanInserted indicate
changes in nbsOdsysFtOperationalStatus."
INDEX { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex }
::= { nbsOdsysFtTable 1 }
NbsOdsysFtEntry ::= SEQUENCE {
nbsOdsysFtChasIndex INTEGER,
nbsOdsysFtBayIndex INTEGER,
nbsOdsysFtOperationalStatus NbsTcStatusSimple,
nbsOdsysFtChIfIndex InterfaceIndex,
nbsOdsysFtPartIndex NbsTcPartIndex,
nbsOdsysFtFanCount INTEGER,
nbsOdsysFtThermActual NbsTcTemperature,
nbsOdsysFtThermLevel NbsTcStatusLevel,
nbsOdsysFtThermThreshLoErr NbsTcTemperature,
nbsOdsysFtThermThreshLoWarn NbsTcTemperature,
nbsOdsysFtThermThreshHiWarn NbsTcTemperature,
nbsOdsysFtThermThreshHiErr NbsTcTemperature
}
nbsOdsysFtChasIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"nbsCmmcChassisIndex of this fan tray's chassis"
::= { nbsOdsysFtEntry 1 }
nbsOdsysFtBayIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fan tray bay/slot number, unique within this chassis"
::= { nbsOdsysFtEntry 2 }
nbsOdsysFtOperationalStatus OBJECT-TYPE
SYNTAX NbsTcStatusSimple
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value notSupported(1) indicates the fan tray is absent."
::= { nbsOdsysFtEntry 3 }
nbsOdsysFtChIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardIfIndex of this fan tray's chassis"
::= { nbsOdsysFtEntry 10 }
nbsOdsysFtPartIndex OBJECT-TYPE
SYNTAX NbsTcPartIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardPartIndex of this fan tray"
::= { nbsOdsysFtEntry 11 }
nbsOdsysFtFanCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of fans in this tray"
::= { nbsOdsysFtEntry 20 }
nbsOdsysFtThermActual OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current temperature reading,
in degrees celsius"
::= { nbsOdsysFtEntry 30}
nbsOdsysFtThermLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of current temperature reading with respect
to the FtTherm threshold objects below"
::= { nbsOdsysFtEntry 40 }
nbsOdsysFtThermThreshLoErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional operating temperature,
in degrees celsius"
::= { nbsOdsysFtEntry 41 }
nbsOdsysFtThermThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe operating temperature,
in degrees celsius"
::= { nbsOdsysFtEntry 42 }
nbsOdsysFtThermThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe operating temperature,
in degrees celsius"
::= { nbsOdsysFtEntry 43 }
nbsOdsysFtThermThreshHiErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional operating temperature,
in degrees celsius"
::= { nbsOdsysFtEntry 44 }
-- ********************************************************************
--
-- Objects for the nbsOdsysPsGrp group
--
-- ********************************************************************
--
-- PSTable (Power Supply Info)
--
nbsOdsysPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF NbsOdsysPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about OptiDriver chassis' power supplies"
::= { nbsOdsysPsGrp 2 }
nbsOdsysPsEntry OBJECT-TYPE
SYNTAX NbsOdsysPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular power supply slot/bay.
Each installed power supply also has entries in
nbsPartHardTable.
The events nbsCmmcTrapPowerSupplyFailure,
nbsCmmcTrapPowerSupplyRestored, nbsCmmcTrapPowerSupplyRemoved,
and nbsCmmcTrapPowerSupplyInserted indicate changes in
nbsOdsysFtOperationalStatus."
INDEX { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex }
::= { nbsOdsysPsTable 1 }
NbsOdsysPsEntry ::= SEQUENCE {
nbsOdsysPsChasIndex INTEGER,
nbsOdsysPsBayIndex INTEGER,
nbsOdsysPsOperationalStatus NbsTcStatusSimple,
nbsOdsysPsChIfIndex InterfaceIndex,
nbsOdsysPsPartIndex NbsTcPartIndex,
nbsOdsysPsFanCount INTEGER,
nbsOdsysPsThermActual NbsTcTemperature,
nbsOdsysPsThermLevel NbsTcStatusLevel,
nbsOdsysPsThermThreshLoErr NbsTcTemperature,
nbsOdsysPsThermThreshLoWarn NbsTcTemperature,
nbsOdsysPsThermThreshHiWarn NbsTcTemperature,
nbsOdsysPsThermThreshHiErr NbsTcTemperature,
nbsOdsysPsVInActual NbsTcMilliVolt,
nbsOdsysPsVInLevel NbsTcStatusLevel,
nbsOdsysPsVInThreshLoErr NbsTcMilliVolt,
nbsOdsysPsVInThreshLoWarn NbsTcMilliVolt,
nbsOdsysPsVInThreshHiWarn NbsTcMilliVolt,
nbsOdsysPsVInThreshHiErr NbsTcMilliVolt,
nbsOdsysPsVOutActual NbsTcMilliVolt,
nbsOdsysPsVOutLevel NbsTcStatusLevel,
nbsOdsysPsVOutThreshLoErr NbsTcMilliVolt,
nbsOdsysPsVOutThreshLoWarn NbsTcMilliVolt,
nbsOdsysPsVOutThreshHiWarn NbsTcMilliVolt,
nbsOdsysPsVOutThreshHiErr NbsTcMilliVolt,
nbsOdsysPsIInActual NbsTcMilliAmp,
nbsOdsysPsIInLevel NbsTcStatusLevel,
nbsOdsysPsIInThreshLoErr NbsTcMilliAmp,
nbsOdsysPsIInThreshLoWarn NbsTcMilliAmp,
nbsOdsysPsIInThreshHiWarn NbsTcMilliAmp,
nbsOdsysPsIInThreshHiErr NbsTcMilliAmp,
nbsOdsysPsIOutActual NbsTcMilliAmp,
nbsOdsysPsIOutLevel NbsTcStatusLevel,
nbsOdsysPsIOutThreshLoErr NbsTcMilliAmp,
nbsOdsysPsIOutThreshLoWarn NbsTcMilliAmp,
nbsOdsysPsIOutThreshHiWarn NbsTcMilliAmp,
nbsOdsysPsIOutThreshHiErr NbsTcMilliAmp
}
nbsOdsysPsChasIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsCmmcChassisIndex of this power supply's chassis"
::= { nbsOdsysPsEntry 1 }
nbsOdsysPsBayIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of this power supply slot/bay"
::= { nbsOdsysPsEntry 2 }
nbsOdsysPsOperationalStatus OBJECT-TYPE
SYNTAX NbsTcStatusSimple
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value notSupported(1) indicates power supply is absent."
::= { nbsOdsysPsEntry 3 }
nbsOdsysPsChIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardIfIndex of this power supply's chassis"
::= { nbsOdsysPsEntry 10 }
nbsOdsysPsPartIndex OBJECT-TYPE
SYNTAX NbsTcPartIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nbsPartHardPartIndex of this power supply"
::= { nbsOdsysPsEntry 11 }
nbsOdsysPsFanCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates how many internal fans this power supply has."
::= { nbsOdsysPsEntry 30 }
nbsOdsysPsThermActual OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current temperature reading,
in degrees celsius"
::= { nbsOdsysPsEntry 40}
nbsOdsysPsThermLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of current temperature reading with respect
to the PsTherm threshold objects below"
::= { nbsOdsysPsEntry 41 }
nbsOdsysPsThermThreshLoErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional operating temperature,
in degrees celsius"
::= { nbsOdsysPsEntry 42 }
nbsOdsysPsThermThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe operating temperature,
in degrees celsius"
::= { nbsOdsysPsEntry 43 }
nbsOdsysPsThermThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe operating temperature,
in degrees celsius"
::= { nbsOdsysPsEntry 44 }
nbsOdsysPsThermThreshHiErr OBJECT-TYPE
SYNTAX NbsTcTemperature
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional operating temperature,
in degrees celsius"
::= { nbsOdsysPsEntry 45 }
nbsOdsysPsVInActual OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the input voltage reading, in millivolts"
::= { nbsOdsysPsEntry 50}
nbsOdsysPsVInLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of input voltage reading with respect
to the PsVIn threshold objects below"
::= { nbsOdsysPsEntry 51 }
nbsOdsysPsVInThreshLoErr OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional input voltage, in millivolts"
::= { nbsOdsysPsEntry 52 }
nbsOdsysPsVInThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe input voltage, in millivolts"
::= { nbsOdsysPsEntry 53 }
nbsOdsysPsVInThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe input voltage, in millivolts"
::= { nbsOdsysPsEntry 54 }
nbsOdsysPsVInThreshHiErr OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional input voltage, in millivolts"
::= { nbsOdsysPsEntry 55 }
nbsOdsysPsVOutActual OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the output voltage reading, in millivolts"
::= { nbsOdsysPsEntry 60}
nbsOdsysPsVOutLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of output voltage reading with respect
to the PsVOut threshold objects below"
::= { nbsOdsysPsEntry 61 }
nbsOdsysPsVOutThreshLoErr OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional output voltage, in millivolts"
::= { nbsOdsysPsEntry 62}
nbsOdsysPsVOutThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe output voltage, in millivolts"
::= { nbsOdsysPsEntry 63 }
nbsOdsysPsVOutThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe output voltage, in millivolts"
::= { nbsOdsysPsEntry 64 }
nbsOdsysPsVOutThreshHiErr OBJECT-TYPE
SYNTAX NbsTcMilliVolt
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional output voltage, in millivolts"
::= { nbsOdsysPsEntry 65 }
nbsOdsysPsIInActual OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the input current reading, in milliamps"
::= { nbsOdsysPsEntry 70}
nbsOdsysPsIInLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of input current reading with respect
to the PsIIn threshold objects below"
::= { nbsOdsysPsEntry 71 }
nbsOdsysPsIInThreshLoErr OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional input current, in milliamps"
::= { nbsOdsysPsEntry 72 }
nbsOdsysPsIInThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe input current, in milliamps"
::= { nbsOdsysPsEntry 73 }
nbsOdsysPsIInThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe input current, in milliamps"
::= { nbsOdsysPsEntry 74 }
nbsOdsysPsIInThreshHiErr OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional input current, in milliamps"
::= { nbsOdsysPsEntry 75 }
nbsOdsysPsIOutActual OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the output current, in milliamps"
::= { nbsOdsysPsEntry 80}
nbsOdsysPsIOutLevel OBJECT-TYPE
SYNTAX NbsTcStatusLevel
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates level of output current reading with respect
to the PsIOut threshold objects below"
::= { nbsOdsysPsEntry 81 }
nbsOdsysPsIOutThreshLoErr OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum functional output current, in milliamps"
::= { nbsOdsysPsEntry 82 }
nbsOdsysPsIOutThreshLoWarn OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the minimum safe output current, in milliamps"
::= { nbsOdsysPsEntry 83 }
nbsOdsysPsIOutThreshHiWarn OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum safe output current, in milliamps"
::= { nbsOdsysPsEntry 84 }
nbsOdsysPsIOutThreshHiErr OBJECT-TYPE
SYNTAX NbsTcMilliAmp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the maximum functional output current, in milliamps"
::= { nbsOdsysPsEntry 85 }
-- ********************************************************************
--
-- Notifications in nbsOdsysEvents
--
-- ********************************************************************
nbsOdsysTrapCcThermLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex,
nbsOdsysCcThermActual, nbsOdsysCcThermLevel }
STATUS current
DESCRIPTION
"Sent when nbsOdsysCcThermLevel changes to anything but
statusGood (4)"
::= { nbsOdsysEvents 30 }
nbsOdsysTrapCcThermLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex,
nbsOdsysCcThermActual, nbsOdsysCcThermLevel }
STATUS current
DESCRIPTION
"Sent when nbsOdsysCcThermLevel changes to statusGood (4)"
::= { nbsOdsysEvents 31 }
nbsOdsysTrapFtThermLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex,
nbsOdsysFtThermActual, nbsOdsysFtThermLevel }
STATUS current
DESCRIPTION
"Sent when fan tray's nbsOdsysFtThermLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 40 }
nbsOdsysTrapFtThermLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysFtChasIndex, nbsOdsysFtBayIndex,
nbsOdsysFtThermActual, nbsOdsysFtThermLevel }
STATUS current
DESCRIPTION
"Sent when fan tray's nbsOdsysFtThermLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 41 }
nbsOdsysTrapPsThermLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsThermActual, nbsOdsysPsThermLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsThermLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 50 }
nbsOdsysTrapPsThermLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsThermActual, nbsOdsysPsThermLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsThermLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 51 }
nbsOdsysTrapPsVInLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsVInActual, nbsOdsysPsVInLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsVInLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 60 }
nbsOdsysTrapPsVInLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsVInActual, nbsOdsysPsVInLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsVInLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 61 }
nbsOdsysTrapPsVOutLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsVOutActual, nbsOdsysPsVOutLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsVOutLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 70 }
nbsOdsysTrapPsVOutLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsVOutActual, nbsOdsysPsVOutLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsVOutLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 71 }
nbsOdsysTrapPsIInLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsIInActual, nbsOdsysPsIInLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsIInLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 80 }
nbsOdsysTrapPsIInLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsIInActual, nbsOdsysPsIInLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsIInLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 81 }
nbsOdsysTrapPsIOutLevelBad NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsIOutActual, nbsOdsysPsIOutLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsIOutLevel changes to
anything but statusGood (4)"
::= { nbsOdsysEvents 90 }
nbsOdsysTrapPsIOutLevelOk NOTIFICATION-TYPE
OBJECTS { nbsOdsysPsChasIndex, nbsOdsysPsBayIndex,
nbsOdsysPsIOutActual, nbsOdsysPsIOutLevel }
STATUS current
DESCRIPTION
"Sent when power supply's nbsOdsysPsIOutLevel changes to
statusGood (4)"
::= { nbsOdsysEvents 91 }
nbsOdsysTrapCcFailed NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
STATUS current
DESCRIPTION
"Triggered when nbsOdsysCcOperationalStatus transitions to
bad (2)"
::= { nbsOdsysEvents 131 }
nbsOdsysTrapCcRestored NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
STATUS current
DESCRIPTION
"Triggered when nbsOdsysCcOperationalStatus transitions to
good (3)"
::= { nbsOdsysEvents 132 }
nbsOdsysTrapCcRemoved NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
STATUS current
DESCRIPTION
"Triggered when control card is removed from chassis"
::= { nbsOdsysEvents 133 }
nbsOdsysTrapCcInserted NOTIFICATION-TYPE
OBJECTS { nbsOdsysCcChasIndex, nbsOdsysCcBayIndex }
STATUS current
DESCRIPTION
"Triggered when control card is inserted into chassis"
::= { nbsOdsysEvents 134 }
END