mibs/MIBS/mrv/NBS-SYSCOMM-MIB
2023-12-05 12:25:34 +01:00

191 lines
5.2 KiB
Plaintext

NBS-SYSCOMM-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
InetAddress, InetAddressPrefixLength
FROM INET-ADDRESS-MIB
nbs
FROM NBS-MIB
;
nbsSyscommMib MODULE-IDENTITY
LAST-UPDATED "201306060000Z" -- June 6, 2013
ORGANIZATION "NBS"
CONTACT-INFO
"For technical support, please contact your service channel"
DESCRIPTION
"Information Base for provisioning ip configuration of managed device."
::= { nbs 214 }
-- *******************************************************************
-- NBS-SYSCOMM-MIB local defines and textual conventions
-- *******************************************************************
nbsSyscommInetGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"TCP/IP configuration of system management card"
::= { nbsSyscommMib 3 }
nbsSyscommEventGrp OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Objects to be included in event notifications"
::= { nbsSyscommMib 100 }
nbsSyscommEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION "Events related to system communications"
::= { nbsSyscommEventGrp 0 }
-- ********************************************************************
--
-- nbsSyscommInetAddrGrp
--
-- ********************************************************************
nbsSyscommInetSlaacAddr OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IPv6 link-local address assigned by the Stateless Address
Autoconfiguration process."
::= { nbsSyscommInetGrp 3 }
nbsSyscommInetSlaacAddrPrefix OBJECT-TYPE
SYNTAX InetAddressPrefixLength
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prefix length of nbsSyscommInetSlaacAddr."
::= { nbsSyscommInetGrp 5 }
nbsSyscommInetAddrAdmin OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Persistent. User-desired IPv6 address.
For IPv4, use the object nbsCmmcSysIpAddr[Admin]"
--DEFVAL { "" }
::= { nbsSyscommInetGrp 10 }
nbsSyscommInetAddrOper OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user-specified Ipv6 address actually in effect.
For IPv4, please refer to the object nbsCmmcSysIpAddrOper."
--DEFVAL { "" }
::= { nbsSyscommInetGrp 11 }
nbsSyscommInetAddrPrefixAdmin OBJECT-TYPE
SYNTAX InetAddressPrefixLength
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The prefix length of nbsSyscommInetAddrAdmin."
DEFVAL { 64 }
::= { nbsSyscommInetGrp 22 }
nbsSyscommInetAddrPrefixOper OBJECT-TYPE
SYNTAX InetAddressPrefixLength
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The prefix length of nbsSyscommInetAddrOper."
::= { nbsSyscommInetGrp 23 }
nbsSyscommGateAddrAdmin OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Persistent. Desired default IPv6 gateway.
For IPv4, use the object nbsCmmcSysDefaultGateway[Admin]."
--DEFVAL { "" }
::= { nbsSyscommInetGrp 30 }
nbsSyscommGateAddrOper OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IPv6 default gateway.
For IPv4, please refer to nbsCmmcSysDefaultGatewayOper."
--DEFVAL { "" }
::= { nbsSyscommInetGrp 31 }
-- ********************************************************************
--
-- nbsSyscommEventGrp
--
-- ********************************************************************
nbsSyscommInetAddrPrior OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value nbsSyscommInetAddrOper had before the last modification"
--DEFVAL { "" }
::= { nbsSyscommEventGrp 311 }
nbsSyscommGateAddrPrior OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value nbsSyscommGateAddrOper had before the last modification"
--DEFVAL { "" }
::= { nbsSyscommEventGrp 331 }
-- ********************************************************************
--
-- nbsSyscommEvents definitions
--
-- ********************************************************************
nbsSyscommInetCfgChanging NOTIFICATION-TYPE
OBJECTS { nbsSyscommInetAddrAdmin, nbsSyscommGateAddrAdmin }
STATUS current
DESCRIPTION
"Sent when before the changes are actually applied. This is a
warning to all SNMP Manager stations that the IP Address is
changing, and they will soon lose contact with this device.
This Notification's nbsCmmcSysTrapTblEntLevel is fatal(2)."
::= { nbsSyscommEvents 30 }
nbsSyscommInetCfgChanged NOTIFICATION-TYPE
OBJECTS { nbsSyscommInetAddrPrior, nbsSyscommGateAddrPrior }
STATUS current
DESCRIPTION
"Sent after changes are complete and have been applied.
This Notification's nbsCmmcSysTrapTblEntLevel is fatal(2)."
::= { nbsSyscommEvents 31 }
END