6522 lines
236 KiB
Plaintext
6522 lines
236 KiB
Plaintext
ALCATEL-IND1-TIMETRA-CHASSIS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
NOTIFICATION-TYPE, Unsigned32,
|
|
Integer32, Gauge32 FROM SNMPv2-SMI
|
|
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
|
|
TEXTUAL-CONVENTION, DateAndTime,
|
|
RowStatus, TimeStamp, TimeInterval,
|
|
TruthValue, MacAddress, RowPointer,
|
|
DisplayString FROM SNMPv2-TC
|
|
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
|
|
TmnxActionType, TmnxPortID,
|
|
TItemDescription, TNamedItemOrEmpty,
|
|
TNamedItem, TmnxOperState,
|
|
TmnxAdminState FROM ALCATEL-IND1-TIMETRA-TC-MIB
|
|
|
|
timetraSRMIBModules, tmnxSRObjs,
|
|
tmnxSRNotifyPrefix, tmnxSRConfs FROM ALCATEL-IND1-TIMETRA-GLOBAL-MIB
|
|
;
|
|
|
|
tmnxChassisMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED "0801010000Z"
|
|
ORGANIZATION "Alcatel"
|
|
CONTACT-INFO
|
|
"Alcatel 7x50 Support
|
|
Web: http://www.alcatel.com/comps/pages/carrier_support.jhtml"
|
|
DESCRIPTION
|
|
"This document is the SNMP MIB module to manage and provision the
|
|
hardware components of the Alcatel 7x50 device.
|
|
|
|
Copyright 2003-2008 Alcatel-Lucent. All rights reserved.
|
|
Reproduction of this document is authorized on the condition that
|
|
the foregoing copyright notice is included.
|
|
|
|
This SNMP MIB module (Specification) embodies Alcatel's
|
|
proprietary intellectual property. Alcatel retains
|
|
all title and ownership in the Specification, including any
|
|
revisions.
|
|
|
|
Alcatel grants all interested parties a non-exclusive
|
|
license to use and distribute an unmodified copy of this
|
|
Specification in connection with management of Alcatel
|
|
products, and without fee, provided this copyright notice and
|
|
license appear on all copies.
|
|
|
|
This Specification is supplied 'as is', and Alcatel
|
|
makes no warranty, either express or implied, as to the use,
|
|
operation, condition, or performance of the Specification."
|
|
|
|
--
|
|
-- Revision History
|
|
--
|
|
REVISION "0801010000Z"
|
|
DESCRIPTION "Rev 6.0 01 Jan 2008 00:00
|
|
6.0 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0701010000Z"
|
|
DESCRIPTION "Rev 5.0 01 Jan 2007 00:00
|
|
5.0 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0603160000Z"
|
|
DESCRIPTION "Rev 4.0 16 Mar 2006 00:00
|
|
4.0 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0508310000Z"
|
|
DESCRIPTION "Rev 3.0 31 Aug 2005 00:00
|
|
3.0 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0501240000Z"
|
|
DESCRIPTION "Rev 2.1 24 Jan 2005 00:00
|
|
2.1 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0401150000Z"
|
|
DESCRIPTION "Rev 2.0 15 Jan 2004 00:00
|
|
2.0 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0308150000Z"
|
|
DESCRIPTION "Rev 1.2 15 Aug 2003 00:00
|
|
1.2 release of the TIMETRA-CHASSIS-MIB."
|
|
|
|
REVISION "0301200000Z"
|
|
DESCRIPTION "Rev 1.0 20 Jan 2003 00:00
|
|
Release 1.0 of the TIMETRA-HW-MIB."
|
|
|
|
REVISION "0008140000Z"
|
|
DESCRIPTION "Rev 0.1 14 Aug 2000 00:00
|
|
Initial version of the TIMETRA-HW-MIB."
|
|
|
|
::= { timetraSRMIBModules 2 }
|
|
|
|
|
|
-- sub-tree for managed objects, and for each functional area
|
|
tmnxHwObjs OBJECT IDENTIFIER ::= { tmnxSRObjs 2 }
|
|
tmnxChassisObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 1 }
|
|
tmnxSlotObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 2 }
|
|
tmnxCardObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 3 }
|
|
-- tmnxPortObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 4 }
|
|
-- tmnxPppObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 5 }
|
|
|
|
tmnxChassisNotificationObjects OBJECT IDENTIFIER ::= { tmnxHwObjs 6 }
|
|
-- tmnxPortNotificationObjects OBJECT IDENTIFIER ::= { tmnxHwObjs 7 }
|
|
tmnxChassisAdminObjects OBJECT IDENTIFIER ::= { tmnxHwObjs 8 }
|
|
-- tmnxFRObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 9 }
|
|
-- tmnxQosAppObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 10 }
|
|
-- tmnxATMObjs OBJECT IDENTIFIER ::= { tmnxHwObjs 11 }
|
|
|
|
tmnxHwNotification OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 2 }
|
|
tmnxChassisNotifyPrefix OBJECT IDENTIFIER ::= { tmnxHwNotification 1}
|
|
tmnxChassisNotification OBJECT IDENTIFIER ::= { tmnxChassisNotifyPrefix 0 }
|
|
-- tmnxPortNotifyPrefix OBJECT IDENTIFIER ::= { tmnxHwNotification 2 }
|
|
-- tmnxPortNotification OBJECT IDENTIFIER ::= { tmnxPortNotifyPrefix 0 }
|
|
-- tmnxPppNotifyPrefix OBJECT IDENTIFIER ::= { tmnxHwNotification 3 }
|
|
-- tmnxPppNotification OBJECT IDENTIFIER ::= { tmnxPppNotifyPrefix 0 }
|
|
-- tAtmNotifyPrefix OBJECT IDENTIFIER ::= { tmnxSrNotifyPrefix 27 }
|
|
-- tAtmNotifications OBJECT IDENTIFIER ::= { tAtmNotifyPrefix 0 }
|
|
|
|
|
|
tmnxHwConformance OBJECT IDENTIFIER ::= { tmnxSRConfs 2 }
|
|
tmnxChassisConformance OBJECT IDENTIFIER ::= { tmnxHwConformance 1 }
|
|
-- tmnxPortConformance OBJECT IDENTIFIER ::= { tmnxHwConformance 2 }
|
|
-- tmnxPppConformance OBJECT IDENTIFIER ::= { tmnxHwConformance 3 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- ALCATEL-IND1-TIMETRA-CHASSIS-MIB textual conventions
|
|
--
|
|
|
|
--
|
|
-- TmnxAlarmState
|
|
--
|
|
TmnxAlarmState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxAlarmState is an enumerated integer whose value indicates
|
|
the current alarm state of a physical or logical component in the
|
|
Alcatel 7x50 SR series system."
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
alarmActive (1),
|
|
alarmCleared (2)
|
|
}
|
|
|
|
--
|
|
-- TmnxChassisIndex
|
|
--
|
|
TmnxChassisIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxChassisIndex is a unique index that identifies a chassis
|
|
within an Alcatel 7x50 system. Note that initial releases will
|
|
support only one chassis in a system."
|
|
SYNTAX INTEGER (1..32)
|
|
|
|
--
|
|
-- TmnxHwIndex
|
|
--
|
|
TmnxHwIndex ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxHwIndex is a unique integer index that identifies an
|
|
Alcatel 7x50 SR series manufactured hardware component, such as
|
|
an IOM, CPM, Fabric or MDA card."
|
|
SYNTAX Integer32 (1..2147483647)
|
|
|
|
TmnxHwIndexOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxHwIndexOrZero is a unique integer index that identifies an
|
|
Alcatel 7x50 SR series manufactured hardware component, such as an
|
|
IOM, CPM, Fabric or MDA card. Also TmnxHwIndexOrZero can be zero."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
--
|
|
-- TmnxHwClass
|
|
--
|
|
TmnxHwClass ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxHwClass is an enumerated integer that identifies the general
|
|
hardware type of a component in the tmnxHwTable."
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
unknown (2),
|
|
chassis (3),
|
|
container (4),
|
|
powerSupply (5),
|
|
fan (6),
|
|
sensor (7),
|
|
ioModule (8),
|
|
cpmModule (9),
|
|
fabricModule (10),
|
|
mdaModule (11),
|
|
flashDiskModule (12),
|
|
port (13),
|
|
mcm (14),
|
|
ccm (15)
|
|
}
|
|
|
|
--
|
|
-- TmnxCardType
|
|
--
|
|
TmnxCardType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxCardType data type is a bit-mask field that describes the
|
|
various Alcatel 7x50 SR series card types. A TmnxCardType bit
|
|
value specifies the index value for the entry in the
|
|
tmnxCardTypeTable used to identify a specific type of card
|
|
manufactured by Alcatel.
|
|
|
|
When multiple bits are set, it can be used to identify a set or
|
|
list of card types used in the tmnxCardTable and tmnxCpmCardTable to
|
|
indicate supported or allowed cards within a specific chassis slot.
|
|
Some example card types might be:
|
|
|
|
sfm-400g -- 400g CPM/SF module
|
|
sfm-200g -- 200g CPM/SF module
|
|
sfm-100g -- 100g CPM/SF module
|
|
iom-20g -- 2 x 10-Gig MDA IOM Card
|
|
"
|
|
SYNTAX Unsigned32
|
|
|
|
--
|
|
-- TmnxChassisType
|
|
--
|
|
TmnxChassisType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxChassisType data type is an integer that specifies
|
|
the index value for the entry in the tmnxChassisTypeTable used to
|
|
identify a specific type of chassis backplane manufactured
|
|
by Alcatel."
|
|
SYNTAX Unsigned32
|
|
|
|
--
|
|
-- TmnxDeviceState
|
|
--
|
|
TmnxDeviceState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxDeviceState data type is an enumerated integer that
|
|
describes the values used to identify states of chassis
|
|
components such as fans and power supplies."
|
|
SYNTAX INTEGER {
|
|
deviceStateUnknown (1),
|
|
deviceNotEquipped (2),
|
|
deviceStateOk (3),
|
|
deviceStateFailed (4),
|
|
deviceStateOutOfService (5)
|
|
}
|
|
|
|
--
|
|
-- TmnxLEDState
|
|
--
|
|
TmnxLEDState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxLEDState data type is an enumerated integer that
|
|
describes the values used to identify state LEDs on Alcatel
|
|
7x50 SR series cards."
|
|
SYNTAX INTEGER {
|
|
ledOff (1),
|
|
ledRed (2),
|
|
ledAmber (3),
|
|
ledYellow (4),
|
|
ledGreen (5),
|
|
ledAmberBlink (6),
|
|
ledYellowBlink (7),
|
|
ledGreenBlink (8)
|
|
}
|
|
|
|
--
|
|
-- TmnxMdaType
|
|
--
|
|
TmnxMdaType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxMdaType data type is an integer that used to identify the
|
|
kind of Media Dependent Adapter (MDA) installed on a card.
|
|
|
|
The value of TmnxMdaType corresponds to the bit number indicated by
|
|
TmnxMDASuppType.
|
|
|
|
A TmnxMdaType value specifies the index value for the entry in the
|
|
tmnxMdaTypeTable used to identify a specific type of MDA
|
|
manufactured by Alcatel."
|
|
SYNTAX Unsigned32
|
|
|
|
--
|
|
-- TmnxMDASuppType
|
|
--
|
|
TmnxMDASuppType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxMDASuppType data type is a SNMP BIT that is used to identify
|
|
the kind of Media Dependent Adapter (MDA) supported on a card.
|
|
|
|
When multiple bits are set, it can be used to identify a set or list
|
|
of supported MDAs within a specific card slot. The MDA types are defined
|
|
in the tmnxMdaTypeTable."
|
|
SYNTAX BITS {
|
|
invalid-MDA-type (0),
|
|
unassigned (1),
|
|
supp-MDA-type-2 (2),
|
|
supp-MDA-type-3 (3),
|
|
supp-MDA-type-4 (4),
|
|
supp-MDA-type-5 (5),
|
|
supp-MDA-type-6 (6),
|
|
supp-MDA-type-7 (7),
|
|
supp-MDA-type-8 (8),
|
|
supp-MDA-type-9 (9),
|
|
supp-MDA-type-10 (10),
|
|
supp-MDA-type-11 (11),
|
|
supp-MDA-type-12 (12),
|
|
supp-MDA-type-13 (13),
|
|
supp-MDA-type-14 (14),
|
|
supp-MDA-type-15 (15),
|
|
supp-MDA-type-16 (16),
|
|
supp-MDA-type-17 (17),
|
|
supp-MDA-type-18 (18),
|
|
supp-MDA-type-19 (19),
|
|
supp-MDA-type-20 (20),
|
|
supp-MDA-type-21 (21),
|
|
supp-MDA-type-22 (22),
|
|
supp-MDA-type-23 (23),
|
|
supp-MDA-type-24 (24),
|
|
supp-MDA-type-25 (25),
|
|
supp-MDA-type-26 (26),
|
|
supp-MDA-type-27 (27),
|
|
supp-MDA-type-28 (28),
|
|
supp-MDA-type-29 (29),
|
|
supp-MDA-type-30 (30),
|
|
supp-MDA-type-31 (31),
|
|
supp-MDA-type-32 (32),
|
|
supp-MDA-type-33 (33),
|
|
supp-MDA-type-34 (34),
|
|
supp-MDA-type-35 (35),
|
|
supp-MDA-type-36 (36),
|
|
supp-MDA-type-37 (37),
|
|
supp-MDA-type-38 (38),
|
|
supp-MDA-type-39 (39),
|
|
supp-MDA-type-40 (40),
|
|
supp-MDA-type-41 (41),
|
|
supp-MDA-type-42 (42),
|
|
supp-MDA-type-43 (43),
|
|
supp-MDA-type-44 (44),
|
|
supp-MDA-type-45 (45),
|
|
supp-MDA-type-46 (46),
|
|
supp-MDA-type-47 (47)
|
|
}
|
|
--
|
|
-- TmnxMDAChanType
|
|
--
|
|
TmnxMDAChanType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxMDAChanType data type indicates the type of channel that
|
|
can be created on an MDA."
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
sonetSts768(1),
|
|
sonetSts192(2),
|
|
sonetSts48(3),
|
|
sonetSts12(4),
|
|
sonetSts3(5),
|
|
sonetSts1(6),
|
|
sdhTug3(7),
|
|
sonetVtg(8),
|
|
sonetVt15(9),
|
|
sonetVt2(10),
|
|
sonetVt3(11),
|
|
sonetVt6(12),
|
|
pdhTu3(13),
|
|
pdhDs3(14),
|
|
pdhE3(15),
|
|
pdhDs1(16),
|
|
pdhE1(17),
|
|
pdhDs0Grp(18)
|
|
}
|
|
|
|
--
|
|
-- TmnxCcmType
|
|
--
|
|
TmnxCcmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxCcmType data type is bit-mask field that describes
|
|
the values used to identify the kind of Chassis Control
|
|
module (CCM) installed on the chassis. A TmnxCcmType bit
|
|
value specifies the index value for the entry in the
|
|
tmnxCcmTypeTable used to identify a specific type of CCM
|
|
manufactured by Alcatel. When multiple bits are set, it can
|
|
be used to identify a set or list of CCM types used in the
|
|
tmnxCcmTable to indicate supported CCMs within a specific
|
|
chassis slot. Some example CCM types are:
|
|
|
|
unknown -- unknown/uninstalled
|
|
ccm-v1 -- Chassis Control Module version 1
|
|
|
|
"
|
|
SYNTAX Unsigned32
|
|
|
|
--
|
|
-- TmnxMcmType
|
|
--
|
|
TmnxMcmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxMcmType data type is bit-mask field that describes
|
|
the values used to identify the kind of MDA Carrier
|
|
module (MCM) installed on the chassis. A TmnxMcmType bit
|
|
value specifies the index value for the entry in the
|
|
tmnxMcmTypeTable used to identify a specific type of MCM
|
|
manufactured by Alcatel. When multiple bits are set, it can
|
|
be used to identify a set or list of MCM types used in the
|
|
tmnxMcmTable to indicate supported MCMs within a specific
|
|
card slot. Some example MCM types are:
|
|
|
|
unknown -- unknown/uninstalled
|
|
mcm-v1 -- MDA Carrier Module version 1
|
|
|
|
"
|
|
SYNTAX Unsigned32
|
|
|
|
--
|
|
-- TmnxSlotNum
|
|
--
|
|
TmnxSlotNum ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxSlotNum data type is an integer that specifies a slot in
|
|
an Alcatel 7x50 SR series chassis."
|
|
SYNTAX INTEGER (1..128)
|
|
|
|
TmnxSlotNumOrZero ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxSlotNumOrZero data type is an integer that specifies a
|
|
slot in an Alcatel 7x50 SR series chassis or zero."
|
|
SYNTAX INTEGER (0..128)
|
|
|
|
--
|
|
-- TmnxPortAdminStatus
|
|
--
|
|
TmnxPortAdminStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired administrative status of this port."
|
|
SYNTAX INTEGER {
|
|
noop (1),
|
|
inService (2),
|
|
outOfService (3),
|
|
diagnose (4)
|
|
}
|
|
|
|
--
|
|
-- TmnxChassisMode
|
|
--
|
|
TmnxChassisMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxChassisMode data type is an enumerated integer that
|
|
specifies the values used to identify which set of scaling numbers
|
|
and features are effective for an Alcatel 7x50 SR series chassis.
|
|
'modeA' corresponds to the scaling and feature set on the existing
|
|
iom-20g. 'modeB' corresponds to the scaling and features that come
|
|
with iom-20g-b. 'modeC' corresponds to the scaling and features that
|
|
come with iom2-20g."
|
|
SYNTAX INTEGER {
|
|
modeA (1),
|
|
modeB (2),
|
|
modeC (3)
|
|
}
|
|
|
|
--
|
|
-- TmnxSETSRefSource
|
|
--
|
|
TmnxSETSRefSource ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxSETSRefSource data type is an enumerated integer that
|
|
describes the values used to identify the Synchronous Equipment
|
|
Timing Subsystem (SETS) timing reference source."
|
|
SYNTAX INTEGER {
|
|
reference1 (1),
|
|
reference2 (2),
|
|
bits (3)
|
|
}
|
|
|
|
--
|
|
-- TmnxSETSRefQualified
|
|
--
|
|
TmnxSETSRefQualified ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxSETSRefQualified data type is an enumerated integer that
|
|
describes the values used to identify whether the reference is
|
|
'qualified' or 'not-qualified' for use by SETS."
|
|
SYNTAX INTEGER {
|
|
qualified (1),
|
|
not-qualified (2)
|
|
}
|
|
|
|
--
|
|
-- TmnxSETSRefAlarm
|
|
--
|
|
TmnxSETSRefAlarm ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxSETSRefAlarm data type is a bitmap that describes the values
|
|
used to identify the alarms on the SETS timing reference source if
|
|
the source is 'not-qualified'.
|
|
|
|
'los' - loss of signal
|
|
'oof' - out of frequency range
|
|
'oopir' - out of pull in range."
|
|
SYNTAX BITS {
|
|
los (0),
|
|
oof (1),
|
|
oopir (2)
|
|
}
|
|
|
|
--
|
|
-- TmnxBITSIfType
|
|
--
|
|
TmnxBITSIfType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxBITSIfType data type is an enumerated integer that describes
|
|
the values used to identify the interface and framing types of a BITS
|
|
(Building Integrated Timing Supply) interface."
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
t1-esf (1),
|
|
t1-sf (2),
|
|
e1-pcm30crc (3),
|
|
e1-pcm31crc (4)
|
|
}
|
|
|
|
--
|
|
-- TmnxCcagId
|
|
--
|
|
TmnxCcagId ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxCcagId is an integer specifying the cross connect aggregation
|
|
group. The value '0' is used when a ccag is not defined and is not
|
|
a valid value when TmnxCcagId is used as an index."
|
|
SYNTAX Integer32 (0|1..8)
|
|
|
|
--
|
|
-- TmnxCcagRate
|
|
--
|
|
TmnxCcagRate ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxCcagRate is an integer specifying the rate for a CCAG member in Kbps.
|
|
The range of TmnxCcagRate is from 0 Kbps to 100Gbps. The value '-1' is used
|
|
for maximum rate available."
|
|
SYNTAX Integer32 (-1|0..100000000)
|
|
|
|
--
|
|
-- TmnxCcagRateOption
|
|
--
|
|
TmnxCcagRateOption ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxCcagRateOption specifies how the defined rate is
|
|
applied to active Cross Connect Adaptors (CCAs).
|
|
aggregate (1) - the defined rate is equally divided among the CCAs in
|
|
the CCAG member list based on the number of active
|
|
CCAs.
|
|
cca (2) - the defined rate is applied to all CCAs in the CCAG
|
|
member list."
|
|
SYNTAX INTEGER {
|
|
aggregate (1),
|
|
cca (2)
|
|
}
|
|
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- ALCATEL-IND1-TIMETRA-CHASSIS-MIB at a glance
|
|
--
|
|
-- timetra (enterprises 6527)
|
|
-- timetraProducts (3)
|
|
-- tmnxSRMIB (1)
|
|
-- tmnxSRConfs (1)
|
|
-- tmnxSRObjs (2)
|
|
-- tmnxHwObjs (tmnxSRObjs 2)
|
|
-- tmnxSRNotifyPrefix (3)
|
|
--
|
|
--
|
|
-- tmnxChassisObjs (tmnxHwObjs 1)
|
|
-- tmnxChassisTotalNumber (1)
|
|
-- tmnxChassisLastChange (2)
|
|
-- tmnxChassisTable (3)
|
|
-- tmnxChassisFanTable (4)
|
|
-- tmnxChassisPowerSupplyTable (5)
|
|
-- tmnxChassisTypeTable (6)
|
|
-- tmnxChassisHwLastChange (7)
|
|
-- tmnxHwTable (8)
|
|
-- tmnxHwContainsTable (9)
|
|
-- tmnxCcmTable (10)
|
|
-- tmnxCcmTypeTable (11)
|
|
--
|
|
-- tmnxSlotObjs (2) - not used
|
|
--
|
|
-- tmnxCardObjs (3)
|
|
-- tmnxCardLastChange (1)
|
|
-- tmnxCardTable (2)
|
|
-- tmnxCpmCardLastChange (3)
|
|
-- tmnxCpmCardTable (4)
|
|
-- tmnxFabricLastChange (5)
|
|
-- tmnxFabricTable (6)
|
|
-- tmnxCpmFlashTable (7)
|
|
-- tmnxMDATable (8)
|
|
-- tmnxCardTypeTable (9)
|
|
-- tmnxMdaTypeTable (10)
|
|
-- tmnxSyncIfTimingTable (11)
|
|
-- tmnxCcagTable (12)
|
|
-- tmnxCcagPathTable (13)
|
|
-- tmnxCcagPathCcTable (14)
|
|
-- tmnxMcmTable (15)
|
|
-- tmnxMcmTypeTable (16)
|
|
-- tmnxMdaClockDomainTable (17)
|
|
--
|
|
-- tmnxPortObjs (4)
|
|
-- tmnxPppObjs (5)
|
|
-- tmnxChassisNotificationObjects (6)
|
|
-- tmnxPortNotificationObjects (7)
|
|
-- tmnxChassisAdminObjects (8)
|
|
-- tmnxFRObjs (9)
|
|
-- tmnxQosAppObjs (10)
|
|
--
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- The Chassis Group
|
|
--
|
|
|
|
|
|
tmnxChassisTotalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of chassis installed in this system. For the first
|
|
release of the Alcatel 7x50 series product, there is only
|
|
1 chassis per system. A multi-chassis system model is supported
|
|
to allow for future product expansion."
|
|
::= { tmnxChassisObjs 1 }
|
|
|
|
tmnxChassisLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the tmnxChassisTable was last changed."
|
|
::= { tmnxChassisObjs 2 }
|
|
|
|
tmnxChassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis table has an entry for each chassis in the system."
|
|
::= { tmnxChassisObjs 3 }
|
|
|
|
tmnxChassisEntry OBJECT-TYPE
|
|
SYNTAX TmnxChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a chassis in the system. The agent
|
|
creates the row for the first chassis in the system, with
|
|
tmnxChassisIndex = 1, which is auto-discovered by the active CPM
|
|
card. Additional chassis entries can be created and deleted via
|
|
SNMP SET operations. Creation requires a SET request containing
|
|
at least tmnxChassisAdminMode and tmnxChassisRowStatus. Note
|
|
that the first Alcatel 7x50 series product release does not
|
|
support multiple chassis, therefore there will not be more
|
|
than one row entry in this table; attempts to create additional
|
|
rows in this table will be denied."
|
|
INDEX { tmnxChassisIndex }
|
|
::= { tmnxChassisTable 1 }
|
|
|
|
TmnxChassisEntry ::=
|
|
SEQUENCE {
|
|
tmnxChassisIndex TmnxChassisIndex,
|
|
tmnxChassisRowStatus RowStatus,
|
|
tmnxChassisName TNamedItemOrEmpty,
|
|
tmnxChassisType TmnxChassisType,
|
|
tmnxChassisLocation TItemDescription,
|
|
tmnxChassisCoordinates TItemDescription,
|
|
tmnxChassisNumSlots Unsigned32,
|
|
tmnxChassisNumPorts Unsigned32,
|
|
tmnxChassisNumPwrSupplies Unsigned32,
|
|
tmnxChassisNumFanTrays Unsigned32,
|
|
tmnxChassisNumFans Unsigned32,
|
|
tmnxChassisCriticalLEDState TmnxLEDState,
|
|
tmnxChassisMajorLEDState TmnxLEDState,
|
|
tmnxChassisMinorLEDState TmnxLEDState,
|
|
tmnxChassisBaseMacAddress MacAddress,
|
|
tmnxChassisCLLICode DisplayString,
|
|
tmnxChassisReboot TmnxActionType,
|
|
tmnxChassisUpgrade TmnxActionType,
|
|
tmnxChassisAdminMode TmnxChassisMode,
|
|
tmnxChassisOperMode TmnxChassisMode,
|
|
tmnxChassisModeForce TmnxActionType,
|
|
tmnxChassisUpdateWaitTime Unsigned32,
|
|
tmnxChassisUpdateTimeLeft Unsigned32,
|
|
tmnxChassisOverTempState INTEGER
|
|
}
|
|
|
|
tmnxChassisIndex OBJECT-TYPE
|
|
SYNTAX TmnxChassisIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this chassis in the system.
|
|
The first release of the product only supports a single chassis
|
|
in the system."
|
|
::= { tmnxChassisEntry 1 }
|
|
|
|
tmnxChassisRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The row status. The creation or deletion of a chassis entry causes
|
|
creation or deletion of corresponding entries in the tmnxCardTable with
|
|
the same tmnxChassisIndex value. Note, the agent will disallow
|
|
chassis deletion if its entries in the card table have not first been
|
|
put into the proper state for removal. The row entry for
|
|
tmnxChassisIndex equal 1 cannot be deleted."
|
|
::= { tmnxChassisEntry 2 }
|
|
|
|
tmnxChassisName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name assigned this chassis. Setting
|
|
tmnxChassisName to the empty string, ''H, resets tmnxChassisName
|
|
to the TiMOS default value."
|
|
DEFVAL { ''H }
|
|
::= { tmnxChassisEntry 3 }
|
|
|
|
|
|
tmnxChassisType OBJECT-TYPE
|
|
SYNTAX TmnxChassisType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of chassis used in this Alcatel 7x50 system. The value of
|
|
tmnxChassisType is the tmnxChassisTypeIndex for the entry in the
|
|
tmnxChassisTypeTable that represents the Alcatel 7x50 SR series
|
|
chassis model for this system. Chassis types are distinguished
|
|
by their backplane type."
|
|
::= { tmnxChassisEntry 4 }
|
|
|
|
tmnxChassisLocation OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user supplied string that indicates the on site location of this
|
|
chassis. This could used for a Common Language Location Identifier,
|
|
CLLI, code string if desired.
|
|
|
|
A CLLI code is an 11-character standardized geographic identifier that
|
|
uniquely identifies the geographic location of places and certain
|
|
functional categories of equipment unique to the telecommunications
|
|
industry.
|
|
|
|
All valid CLLI codes are created, updated and maintained in the
|
|
Central Location Online Entry System (CLONES) database."
|
|
DEFVAL { ''H }
|
|
::= { tmnxChassisEntry 5 }
|
|
|
|
tmnxChassisCoordinates OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user supplied string that indicates the Global Positioning
|
|
System (GPS) coordinates for the location of this chassis.
|
|
|
|
N 45 58 23, W 34 56 12
|
|
N37 37' 00 latitude, W122 22' 00 longitude
|
|
N36*39.246' W121*40.121'
|
|
|
|
Two-dimensional GPS positioning offers latitude and longitude
|
|
information as a four dimensional vector:
|
|
|
|
<Direction, hours, minutes, seconds>
|
|
|
|
where Direction is one of the four basic values: N, S, W, E; hours
|
|
ranges from 0 to 180 (for latitude) and 0 to 90 for longitude, and,
|
|
finally, minutes and seconds range from 0 to 60.
|
|
|
|
Thus <W, 122, 56, 89> is an example of longitude and <N, 85, 66, 43>
|
|
is an example of latitude.
|
|
|
|
Four bytes of addressing space (one byte for each of the four
|
|
dimensions) are necessary to store latitude and four bytes are also
|
|
sufficient to store longitude. Thus eight bytes total are necessary
|
|
to address the whole surface of earth with precision down to 0.1
|
|
mile! Notice that if we desired precision down to 0.001 mile (1.8
|
|
meters) then we would need just five bytes for each component, or ten
|
|
bytes together for the full address (as military versions provide)."
|
|
DEFVAL { ''H }
|
|
::= { tmnxChassisEntry 6 }
|
|
|
|
tmnxChassisNumSlots OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of slots in this chassis that are available for plug-in
|
|
cards. This includes both fabric and IOM cards"
|
|
::= { tmnxChassisEntry 7 }
|
|
|
|
tmnxChassisNumPorts OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of ports currently installed in this chassis.
|
|
This count does not include the Ethernet ports on the CPM cards
|
|
that are used for management access."
|
|
::= { tmnxChassisEntry 8 }
|
|
|
|
tmnxChassisNumPwrSupplies OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of power supplies installed in this chassis."
|
|
::= { tmnxChassisEntry 9 }
|
|
|
|
tmnxChassisNumFanTrays OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of fan trays installed in this chassis."
|
|
::= { tmnxChassisEntry 10 }
|
|
|
|
tmnxChassisNumFans OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of fans installed in this chassis."
|
|
::= { tmnxChassisEntry 11 }
|
|
|
|
tmnxChassisCriticalLEDState OBJECT-TYPE
|
|
SYNTAX TmnxLEDState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the Critical LED in this chassis."
|
|
::= { tmnxChassisEntry 12 }
|
|
|
|
tmnxChassisMajorLEDState OBJECT-TYPE
|
|
SYNTAX TmnxLEDState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the Major LED in this chassis."
|
|
::= { tmnxChassisEntry 13 }
|
|
|
|
tmnxChassisMinorLEDState OBJECT-TYPE
|
|
SYNTAX TmnxLEDState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the Minor LED in this chassis."
|
|
::= { tmnxChassisEntry 14 }
|
|
|
|
tmnxChassisBaseMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base chassis ethernet MAC address. Special purpose MAC
|
|
addresses used by the system software are constructed as
|
|
offsets from this base address."
|
|
::= { tmnxChassisEntry 15 }
|
|
|
|
tmnxChassisCLLICode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Common Language Location Identifier (CLLI) code is an 11-character
|
|
standardized geographic identifier that uniquely identifies the
|
|
geographic location of places and certain functional categories of
|
|
equipment unique to the telecommunications industry.
|
|
If the set on this object specifies a non-null string, the string will
|
|
automatically be truncated or padded(with spaces) to 11 characters."
|
|
::= { tmnxChassisEntry 16 }
|
|
|
|
tmnxChassisReboot OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this tmnxChassisReboot to 'doAction' causes a soft-reboot
|
|
of the entire chassis including all the CPM and IOM cards.
|
|
|
|
Note that the reboot action is likely to occur before the SNMP
|
|
SET response can be transmitted."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxChassisEntry 17 }
|
|
|
|
tmnxChassisUpgrade OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this tmnxChassisUpgrade to 'doAction' causes an upgrade
|
|
of all firmware and a reboot of the entire chassis including all
|
|
the CPM and IOM cards.
|
|
|
|
CAUTION: This upgrade and reboot may take several minutes to
|
|
complete. The chassis MUST NOT be reset or powered down,
|
|
nor cards inserted or removed, during this process. Any of
|
|
these prohibited actions may cause the cards to be rendered
|
|
inoperable.
|
|
|
|
tmnxChassisUpgrade and tmnxChassisReboot must be set
|
|
together in the same SNMP SET request PDU or else the SET request
|
|
will fail with an inconsistentValue error.
|
|
|
|
Note that the reboot action is likely to occur before the SNMP
|
|
SET response can be transmitted."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxChassisEntry 18 }
|
|
|
|
tmnxChassisAdminMode OBJECT-TYPE
|
|
SYNTAX TmnxChassisMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"The value of tmnxChassisAdminMode specifies the scaling and feature
|
|
set for the IOM cards in the chassis. Setting this variable to
|
|
'modeA' causes all IOM cards in the chassis to use the scaling
|
|
and feature sets supported on the iom-20g card type. Setting
|
|
tmnxChassisAdminMode to 'modeB' corresponds to the scaling and feature
|
|
sets supported on the iom-20g-b card type. 'modeC' corresponds to the
|
|
scaling and feature sets supported on the iom2-20g card type.
|
|
|
|
An attempt to change the value of tmnxChassisAdminMode from 'modeA'
|
|
to 'modeB' (upgrade) or 'modeC' (upgrade) without also setting
|
|
tmnxChassisModeForce to a value of 'doAction' in the same SNMP SET
|
|
request, will fail with an inconsistentValue error if there are any IOM
|
|
cards in the chassis with a value of 'iom-20g' for tmnxCardAssignedType.
|
|
|
|
An attempt to change the value of tmnxChassisAdminMode from 'modeB'
|
|
to 'modeC' (upgrade) without also setting tmnxChassisModeForce to
|
|
a value of 'doAction' in the same SNMP SET request, will fail with an
|
|
inconsistentValue error if there are any IOM cards in the chassis with
|
|
a value of 'iom-20g-b' for tmnxCardAssignedType.
|
|
|
|
'modeB' scaling and feature sets cannot be supported on the iom-20g
|
|
card. 'modeC' scaling feature set cannot be supported on either on
|
|
the iom-20g or the iom-20g-b."
|
|
|
|
DEFVAL { modeA }
|
|
::= { tmnxChassisEntry 19 }
|
|
|
|
tmnxChassisOperMode OBJECT-TYPE
|
|
SYNTAX TmnxChassisMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"The value of tmnxChassisOperMode indicates the operational scaling
|
|
and feature set for the IOM cards in the chassis. Changing the value
|
|
of tmnxChassisAdminMode from 'modeB' to 'modeA' (downgrade) will
|
|
result in tmnxChassisAdminMode indicating 'modeA' while
|
|
tmnxChassisOperMode indicates 'modeB' untill the configuration is
|
|
saved and the system rebooted, at which point, the actual downgrade
|
|
will take effect.
|
|
|
|
Changing the value of tmnxChassisAdminMode from 'modeC' to either
|
|
'modeB' (downgrade) or 'modeA' (downgrade) will result in
|
|
tmnxChassisAdminMode indicating 'modeB' or 'modeA' respectively while
|
|
tmnxChassisOperMode indicates 'modeC' untill the configuration is
|
|
saved and the system rebooted, at which point, the actual downgrade
|
|
will take effect.
|
|
|
|
'modeB' scaling and feature sets cannot be supported on the iom-20g
|
|
card. 'modeC' scaling feature set cannot be supported on either on
|
|
the iom-20g or the iom-20g-b."
|
|
::= { tmnxChassisEntry 20 }
|
|
|
|
tmnxChassisModeForce OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting tmnxChassisModeForce to a value of 'doAction' in the
|
|
same SNMP SET request where tmnxChassisAdminMode is set to 'modeB'
|
|
allows the chassis to be upgraded to 'modeB' even if there are
|
|
IOM cards in the chassis with a value of 'iom-20g' for
|
|
tmnxCardAssignedType.
|
|
|
|
Setting tmnxChassisModeForce to a value of 'doAction' in the
|
|
same SNMP SET request where tmnxChassisAdminMode is set to 'modeC'
|
|
allows the chassis to be upgraded to 'modeC' even if there are
|
|
IOM cards in the chassis with a value of 'iom2-20g' for
|
|
tmnxCardAssignedType.
|
|
|
|
An attempt to set tmnxChassisModeForce to 'doAction' without
|
|
also setting tmnxChassisAdminMode, in the same SNMP SET request
|
|
will fail with an inconsistentValue error.
|
|
|
|
-----------------------------------------------------------------------
|
|
Mode change | Assigned card | Force | Result
|
|
-----------------------------------------------------------------------
|
|
a to b (upgrade) | iom-20g | not-set | error
|
|
a to b (upgrade) | iom-20g | set | mode b with warnings
|
|
a to b (upgrade) | iom-20g-b | not-set | mode b
|
|
a to b (upgrade) | iom-20g-b | set | mode b
|
|
a to c (upgrade) | iom-20g | not-set | error
|
|
a to c (upgrade) | iom-20g | set | mode c with warnings
|
|
a to c (upgrade) | iom2-20g | not-set | mode c
|
|
a to c (upgrade) | iom2-20g | set | mode c
|
|
b to c (upgrade) | iom-20g-b | not-set | error
|
|
b to c (upgrade) | iom-20g-b | set | mode c with warnings
|
|
b to c (upgrade) | iom2-20g | not-set | mode c
|
|
b to c (upgrade) | iom2-20g | set | mode c
|
|
b to a (downgrade)| iom-20g | not-set | mode a on save and reboot
|
|
b to a (downgrade)| iom-20g | set | mode a on save and reboot
|
|
b to a (downgrade)| iom-20g-b | not-set | mode a on save and reboot
|
|
b to a (downgrade)| iom-20g-b | set | mode a on save and reboot
|
|
c to a (downgrade)| iom-20g | not-set | mode a on save and reboot
|
|
c to a (downgrade)| iom-20g | set | mode a on save and reboot
|
|
c to a (downgrade)| iom2-20g | not-set | mode a on save and reboot
|
|
c to a (downgrade)| iom2-20g | set | mode a on save and reboot
|
|
c to b (downgrade)| iom-20g-b | not-set | mode b on save and reboot
|
|
c to b (downgrade)| iom-20g-b | set | mode b on save and reboot
|
|
c to b (downgrade)| iom2-20g | not-set | mode b on save and reboot
|
|
c to b (downgrade)| iom2-20g | set | mode b on save and reboot
|
|
-----------------------------------------------------------------------"
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxChassisEntry 21 }
|
|
|
|
tmnxChassisUpdateWaitTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (15..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The value of tmnxChassisUpdateWaitTime specifies the time to wait
|
|
before rebooting IOM cards running older software versions following
|
|
a software upgrade or downgrade activity switchover. This object
|
|
was obsoleted in release 5.0."
|
|
DEFVAL { 15 }
|
|
::= { tmnxChassisEntry 22 }
|
|
|
|
tmnxChassisUpdateTimeLeft OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Following a software upgrade or downgrade activity switchover,
|
|
the value of tmnxChassisUpdateTimeLeft indicates the time remaining
|
|
before IOM cards or MDAs running older software versions will be
|
|
rebooted."
|
|
::= { tmnxChassisEntry 23 }
|
|
|
|
tmnxChassisOverTempState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stateOk (1),
|
|
stateOverTemp (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current Over Temperature state of this chassis.
|
|
|
|
stateOk Indicates chassis is below the temperature threshold.
|
|
stateOverTemp Indicates chassis is above the temperature threshold.
|
|
"
|
|
::= { tmnxChassisEntry 24 }
|
|
|
|
--
|
|
-- Fan Table
|
|
--
|
|
|
|
tmnxChassisFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxChassisFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about fan trays."
|
|
::= { tmnxChassisObjs 4 }
|
|
|
|
tmnxChassisFanEntry OBJECT-TYPE
|
|
SYNTAX TmnxChassisFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information regarding a fan tray."
|
|
INDEX { tmnxChassisIndex, tmnxChassisFanIndex }
|
|
::= { tmnxChassisFanTable 1 }
|
|
|
|
TmnxChassisFanEntry ::=
|
|
SEQUENCE {
|
|
tmnxChassisFanIndex Unsigned32,
|
|
tmnxChassisFanOperStatus TmnxDeviceState,
|
|
tmnxChassisFanSpeed INTEGER
|
|
}
|
|
|
|
tmnxChassisFanIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies a specific fan tray in the
|
|
chassis."
|
|
::= { tmnxChassisFanEntry 1 }
|
|
|
|
tmnxChassisFanOperStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Fan tray."
|
|
::= { tmnxChassisFanEntry 2 }
|
|
|
|
tmnxChassisFanSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
halfSpeed (2),
|
|
fullSpeed (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxChassisFanSpeed indicates if the fans in this
|
|
fan tray are running at 'halfSpeed' or 'fullSpeed'."
|
|
::= { tmnxChassisFanEntry 3 }
|
|
|
|
--
|
|
-- Power Supply table
|
|
--
|
|
|
|
tmnxChassisPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxChassisPowerSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about power supply trays."
|
|
::= { tmnxChassisObjs 5 }
|
|
|
|
tmnxChassisPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX TmnxChassisPowerSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information regarding a power supply tray."
|
|
INDEX { tmnxChassisIndex, tmnxChassisPowerSupplyId }
|
|
::= { tmnxChassisPowerSupplyTable 1 }
|
|
|
|
TmnxChassisPowerSupplyEntry ::=
|
|
SEQUENCE {
|
|
tmnxChassisPowerSupplyId Unsigned32,
|
|
tmnxChassisPowerSupplyACStatus TmnxDeviceState,
|
|
tmnxChassisPowerSupplyDCStatus TmnxDeviceState,
|
|
tmnxChassisPowerSupplyTempStatus TmnxDeviceState,
|
|
tmnxChassisPowerSupplyTempThreshold Integer32,
|
|
tmnxChassisPowerSupply1Status TmnxDeviceState,
|
|
tmnxChassisPowerSupply2Status TmnxDeviceState,
|
|
tmnxChassisPowerSupplyAssignedType INTEGER,
|
|
tmnxChassisPowerSupplyInputStatus TmnxDeviceState,
|
|
tmnxChassisPowerSupplyOutputStatus TmnxDeviceState
|
|
}
|
|
|
|
tmnxChassisPowerSupplyId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique identifier index for a power supply tray in the chassis."
|
|
::= { tmnxChassisPowerSupplyEntry 1 }
|
|
|
|
tmnxChassisPowerSupplyACStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tmnxChassisPowerSupplyACStatus is 'deviceStateOk',
|
|
the input AC voltage is within range. If the value is
|
|
'deviceStateFailed', an AC voltage out of range condition has been
|
|
detected. A value of 'deviceNotEquipped' indicates that the AC
|
|
power supply is not present."
|
|
::= { tmnxChassisPowerSupplyEntry 2 }
|
|
|
|
tmnxChassisPowerSupplyDCStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tmnxChassisPowerSupplyDCStatus is 'deviceStateOk',
|
|
the input DC voltage is within range. If the value is
|
|
'deviceStateFailed', an DC voltage out of range condition has been
|
|
detected. A value of 'deviceNotEquipped' indicates that the DC
|
|
power supply is not present."
|
|
::= { tmnxChassisPowerSupplyEntry 3 }
|
|
|
|
tmnxChassisPowerSupplyTempStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tmnxChassisPowerSupplyTempStatus is 'deviceStateOk',
|
|
the current temperature is within acceptable range. If the value is
|
|
'deviceStateFailed', a temperature too high condition has been
|
|
detected."
|
|
::= { tmnxChassisPowerSupplyEntry 4 }
|
|
|
|
tmnxChassisPowerSupplyTempThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature threshold for this power supply tray in degrees
|
|
celsius. When the temperature raises above
|
|
tmnxChassisPowerSupplyTempThreshold, a 'temperature too high'
|
|
event will be generated."
|
|
::= { tmnxChassisPowerSupplyEntry 5 }
|
|
|
|
tmnxChassisPowerSupply1Status OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The overall status of an equipped power supply. For AC multiple power
|
|
supplies, this represents the overall status of the first power supply
|
|
in the tray (or shelf). For any other type, this represents the overall
|
|
status of the power supply. If tmnxChassisPowerSupply1Status is
|
|
'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A
|
|
value of 'deviceStateFailed' represents a condition where at least one
|
|
monitored status is in a failed state."
|
|
::= { tmnxChassisPowerSupplyEntry 6 }
|
|
|
|
tmnxChassisPowerSupply2Status OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The overall status of an equipped power supply. For AC multiple power
|
|
supplies, this represents the overall status of the second power supply
|
|
in the tray (or shelf). For any other type, this field is unused and
|
|
set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is
|
|
'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A
|
|
value of 'deviceStateFailed' represents a condition where at least one
|
|
monitored status is in a failed state."
|
|
::= { tmnxChassisPowerSupplyEntry 7 }
|
|
|
|
tmnxChassisPowerSupplyAssignedType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (0),
|
|
dc (1),
|
|
acSingle (2),
|
|
acMultiple (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxChassisPowerSupplyAssignedType configures the type of power supply
|
|
for a platform. Based on the value assigned to this object, various
|
|
power supply monitoring signals will be interpreted. For example, if
|
|
a platform is provisioned to use DC power supplies, then the signal
|
|
that indicates an AC power supply is missing can be ignored.
|
|
This is required for proper generation of traps and LED management."
|
|
::= { tmnxChassisPowerSupplyEntry 8 }
|
|
|
|
tmnxChassisPowerSupplyInputStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tmnxChassisPowerSupplyInputStatus is 'deviceStateOk',
|
|
the input voltage of the power supply is within range. If the value
|
|
is 'deviceStateFailed', an input voltage out of range condition has
|
|
been detected. A value of 'deviceNotEquipped' indicates that the power
|
|
supply is not present."
|
|
::= { tmnxChassisPowerSupplyEntry 9 }
|
|
|
|
tmnxChassisPowerSupplyOutputStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the value of tmnxChassisPowerSupplyOutputStatus is 'deviceStateOk',
|
|
the output voltage of the power supply is within range. If the value
|
|
is 'deviceStateFailed', an output voltage out of range condition has
|
|
been detected. A value of 'deviceNotEquipped' indicates that the power
|
|
supply is not present."
|
|
::= { tmnxChassisPowerSupplyEntry 10 }
|
|
|
|
--
|
|
-- Alcatel 7x50 SR series Chassis Type Defintion Table
|
|
--
|
|
tmnxChassisTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxChassisTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis type table has an entry for each Alcatel 7x50 SR series
|
|
chassis model."
|
|
::= { tmnxChassisObjs 6 }
|
|
|
|
tmnxChassisTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxChassisTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7x50 SR series Chassis model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxChassisTypeIndex }
|
|
::= { tmnxChassisTypeTable 1 }
|
|
|
|
TmnxChassisTypeEntry ::=
|
|
SEQUENCE {
|
|
tmnxChassisTypeIndex TmnxChassisType,
|
|
tmnxChassisTypeName TNamedItemOrEmpty,
|
|
tmnxChassisTypeDescription TItemDescription,
|
|
tmnxChassisTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxChassisTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxChassisType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Alcatel
|
|
7x50 SR series chassis model."
|
|
::= { tmnxChassisTypeEntry 1 }
|
|
|
|
tmnxChassisTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Alcatel
|
|
7x50 SR series chassis model. This name string may be used in
|
|
CLI commands to specify a particular chassis model type."
|
|
::= { tmnxChassisTypeEntry 2 }
|
|
|
|
tmnxChassisTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Alcatel 7x50 SR series chassis model."
|
|
::= { tmnxChassisTypeEntry 3 }
|
|
|
|
tmnxChassisTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxChassisTypeStatus has a value of 'true' it indicates that
|
|
this chassis model is supported in this revision of the management
|
|
software. When it has a value of 'false' there is no support."
|
|
::= { tmnxChassisTypeEntry 4 }
|
|
|
|
|
|
--
|
|
-- Alcatel 7x50 SR series Hardware Components Table
|
|
--
|
|
tmnxHwLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the tmnxHwTable was last changed."
|
|
::= { tmnxChassisObjs 7 }
|
|
|
|
tmnxHwTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxHwEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxHwTable has an entry for each managed hardware component
|
|
in the Alcatel 7x50 SR series system's chassis. Examples of
|
|
these hardware component types are IOM, Fabric, and CPM cards,
|
|
MCM and CCM, and MDA modules. Similar information for physical ports
|
|
is in the tmnxPortObjs."
|
|
::= { tmnxChassisObjs 8 }
|
|
|
|
tmnxHwEntry OBJECT-TYPE
|
|
SYNTAX TmnxHwEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7x50 SR series manufactured
|
|
hardware component. Entries cannot be created and deleted via
|
|
SNMP SET operations. When an entry is created in one of the
|
|
card tables, IOM, CPM, Fabric or MDA, a tmnxHwEntry is created
|
|
for the common hardware management information for that card
|
|
in that chassis. When the card is removed from the chassis,
|
|
its corresponding tmnxHwEntry is deleted.
|
|
|
|
The tmnxHwIndex is bitmapped:
|
|
|
|
| 32 25 | 24 17 | 16 9 | 8 1 |
|
|
+-------------+-------------+-------------+-------------+
|
|
| TmnxHwClass | 00000000 | Slot | number |
|
|
+-------------+-------------+-------------+-------------+
|
|
|
|
The Slot field is only used for components on cards in
|
|
slots. It is zero for all others.
|
|
|
|
The number field starts from 1 and indicates which component.
|
|
E.g. Power supply 1 or 2."
|
|
|
|
|
|
INDEX { tmnxChassisIndex, tmnxHwIndex }
|
|
::= { tmnxHwTable 1 }
|
|
|
|
TmnxHwEntry ::=
|
|
SEQUENCE {
|
|
tmnxHwIndex TmnxHwIndex,
|
|
tmnxHwID RowPointer,
|
|
tmnxHwMfgString SnmpAdminString,
|
|
tmnxHwMfgBoardNumber OCTET STRING,
|
|
tmnxHwSerialNumber SnmpAdminString,
|
|
tmnxHwManufactureDate SnmpAdminString,
|
|
tmnxHwClass TmnxHwClass,
|
|
tmnxHwName TNamedItemOrEmpty,
|
|
tmnxHwAlias TNamedItemOrEmpty,
|
|
tmnxHwAssetID SnmpAdminString,
|
|
tmnxHwCLEI SnmpAdminString,
|
|
tmnxHwIsFRU TruthValue,
|
|
tmnxHwContainedIn Integer32,
|
|
tmnxHwParentRelPos Integer32,
|
|
tmnxHwAdminState INTEGER,
|
|
tmnxHwOperState INTEGER,
|
|
tmnxHwTempSensor TruthValue,
|
|
tmnxHwTemperature Integer32,
|
|
tmnxHwTempThreshold Integer32,
|
|
tmnxHwBootCodeVersion DisplayString,
|
|
tmnxHwSoftwareCodeVersion DisplayString,
|
|
tmnxHwSwLastBoot DateAndTime,
|
|
tmnxHwSwState INTEGER,
|
|
tmnxHwAlarmState TmnxAlarmState,
|
|
tmnxHwLastAlarmEvent RowPointer,
|
|
tmnxHwClearAlarms TmnxActionType,
|
|
tmnxHwSwImageSource INTEGER,
|
|
tmnxHwMfgDeviations SnmpAdminString,
|
|
tmnxHwBaseMacAddress MacAddress,
|
|
tmnxHwFailureReason DisplayString
|
|
}
|
|
|
|
tmnxHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIndex is a unique index that identifies
|
|
common management information for Alcatel 7x50 SR series
|
|
manufactured hardware components within the specified chassis."
|
|
::= { tmnxHwEntry 1 }
|
|
|
|
tmnxHwID OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwID is an object identifier that points to
|
|
the table and row entry with additional management information
|
|
specific to this hardware component's class."
|
|
::= { tmnxHwEntry 2 }
|
|
|
|
tmnxHwMfgString OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..253))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxHwMfgString contains unspecified Alcatel 7x50 SR series
|
|
manufacturing information and includes the Alcatel vendor information."
|
|
::= { tmnxHwEntry 3 }
|
|
|
|
tmnxHwMfgBoardNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxHwMfgBoardNumber contains the part number information."
|
|
::= { tmnxHwEntry 4 }
|
|
|
|
tmnxHwSerialNumber OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique Alcatel 7x50 SR series serial number of the hardware
|
|
component."
|
|
::= { tmnxHwEntry 5 }
|
|
|
|
tmnxHwManufactureDate OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturing date of the hardware component in 'mmddyyyy'
|
|
ascii format."
|
|
::= { tmnxHwEntry 6 }
|
|
|
|
tmnxHwClass OBJECT-TYPE
|
|
SYNTAX TmnxHwClass
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwClass indicates the general hardware type of this
|
|
component. If no appropriate enumeration exists for this hardware
|
|
component then the value 'other (1)' is used. If the agent cannot
|
|
identify this hardware component then the value 'unknown (2)' is
|
|
used."
|
|
::= { tmnxHwEntry 7 }
|
|
|
|
tmnxHwName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwName is the name of the component as assigned
|
|
by the system software itself and is suitable for use in CLI commands.
|
|
This may be a text name such as 'console' or a port ID such as '2/2'.
|
|
|
|
If there is no predefined name then a zero length string is returned.
|
|
|
|
Note that the value of tmnxHwName for two component entries will
|
|
be the same if the CLI does not distinguish between them, e.g. the
|
|
chassis slot-1 and the card in slot-1."
|
|
::= { tmnxHwEntry 8 }
|
|
|
|
tmnxHwAlias OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwAlias is the administrative name assigned to this
|
|
hardware component by the CLI user or network manager. It is saved
|
|
across re-initializations and reboots of the system."
|
|
DEFVAL { ''H }
|
|
::= { tmnxHwEntry 9 }
|
|
|
|
tmnxHwAssetID OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwAssetID is an administratively assigned asset
|
|
tracking identifier for this hardware component. It is saved across
|
|
re-initializations and reboots of the system. If no asset tracking
|
|
information is associated with this hardware component, a zero-length
|
|
string is returned to an SNMP get request.
|
|
|
|
Some hardware components do not have asset tracking identifiers.
|
|
Components for which tmnxHwIsFRU has a value of 'false' do not
|
|
need their own unique asset tracking identifier. In this case, the
|
|
agent denies write access to this object and returns a zero-length
|
|
string to an SNMP get request."
|
|
DEFVAL { ''H }
|
|
::= { tmnxHwEntry 10 }
|
|
|
|
tmnxHwCLEI OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(10))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Common Language Equipment Identifier, CLEI, code is a unique
|
|
10-character identifier, that is fixed by the manufacturer. It
|
|
consists of ten alphanumeric characters. The first seven characters
|
|
present a concise summary of an equipment entity's circuit or
|
|
transport capabilities, e.g., functional, electrical, bandwidth, etc.
|
|
CLEI codes for plug-in or portable equipment with the same first
|
|
seven characters (CLEI-7) are considered bidirectionally
|
|
interchangeable and group under a G level record. Most licensees
|
|
plug-in inventories and records are controlled at the group level.
|
|
The eighth character denotes the reference source used for coding
|
|
the item, and the last two characters denote manufacturing vintage
|
|
or version, and other complemental information.
|
|
|
|
A ten-character CLEI code that is developed for a specific piece of
|
|
equipment is unique within the CLEI code universe and is used in A
|
|
level records; the code is not assigned to any other equipment piece.
|
|
Equipment is coded to a first or major application. When the same
|
|
equipment is usable in another application or system, it is not
|
|
recorded nor are additional codes developed for that purpose."
|
|
REFERENCE
|
|
"Bellcore (Telcordia Technologies) GR-485."
|
|
::= { tmnxHwEntry 11 }
|
|
|
|
tmnxHwIsFRU OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIsFRU indicates whether or not this hardware
|
|
component is a Field Replaceable Unit (FRU) or not. Those components
|
|
that are permanently contained within a FRU have a value of 'false'."
|
|
::= { tmnxHwEntry 12 }
|
|
|
|
tmnxHwContainedIn OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwContainedIn is the tmnxHwIndex value for the
|
|
row entry of the hardware component that contains this component.
|
|
A value of zero indicates that this component is not contained in any
|
|
other component."
|
|
::= { tmnxHwEntry 13 }
|
|
|
|
tmnxHwParentRelPos OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwParentRelPos indicates the relative position of
|
|
this hardware component among all its 'sibling' components. A sibling
|
|
component shares the same instance values for tmnxHwContainedIn and
|
|
tmnxHwClass objects.
|
|
|
|
If the associated value of tmnxHwContainedIn is zero, then the value -1
|
|
is returned."
|
|
::= { tmnxHwEntry 14 }
|
|
|
|
tmnxHwAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noop (1),
|
|
inService (2),
|
|
outOfService (3),
|
|
diagnose (4),
|
|
operateSwitch (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired administrative status of this hardware component. Write
|
|
access will be denied for those components that do not have
|
|
administrative status. An attempt to set tmnxHwAdminState to
|
|
'operateSwitch (5)' will fail if the hardware component is not part
|
|
of a redundant pair. Some examples of redundant hardware are the
|
|
CPM cards and fabric cards."
|
|
DEFVAL { noop }
|
|
::= { tmnxHwEntry 15 }
|
|
|
|
tmnxHwOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
inService (2),
|
|
outOfService (3),
|
|
diagnosing (4),
|
|
failed (5),
|
|
booting (6),
|
|
empty (7),
|
|
provisioned (8),
|
|
unprovisioned (9),
|
|
upgrade (10),
|
|
downgrade (11),
|
|
inServiceUpgrade (12),
|
|
inServiceDowngrade (13),
|
|
resetPending (14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual operational status of this hardware component.
|
|
|
|
unknown (1) Status cannot be determined
|
|
|
|
inService (2) Online - If tmnxHwClass has a value of
|
|
'ioModule (8)' or 'cpmModule (9), the
|
|
card is present, booted, configured,
|
|
and running.
|
|
|
|
outOfService (3) Ready - The hardware component is OK
|
|
but is down because tmnxHwAdminState has
|
|
a value of 'outOfService (3)'.
|
|
|
|
diagnosing (4) Not implemented.
|
|
|
|
failed (5) This hardware component has failed. The
|
|
value of tmnxHwFailureReason indicates
|
|
the type of failure. If tmnxHwClass has
|
|
a value of 'ioModule(8)' or 'cpmModule(9)',
|
|
there is a card in the slot but it has
|
|
failed.
|
|
|
|
booting (6) A card is in the transitional startup state.
|
|
|
|
empty (7) There is no card in the slot and it has
|
|
not been pre-configured.
|
|
|
|
provisioned (8) There is no card in the slot but it has
|
|
been pre-configured.
|
|
|
|
unprovisioned (9) There is a card in the slot but it is not
|
|
configured.
|
|
|
|
upgrade (10) Card software version is compatible with
|
|
and newer than that running on the current
|
|
active CPM.
|
|
|
|
downgrade (11) Card software version is compatible with
|
|
and older than that running on the current
|
|
active CPM.
|
|
|
|
inServiceUpgrade (12) Card is inService and the card software
|
|
version is compatible with and newer than
|
|
that running on the current active CPM.
|
|
This state applies only to a standby CPM
|
|
card. This enumeration is no longer
|
|
supported as of release 5.0.
|
|
|
|
inServiceDowngrade (13) Card is inService and the card software
|
|
is compatible with and older than that
|
|
running on the current active CPM. This
|
|
state applies only to a standby CPM card.
|
|
This enumeration is no longer supported
|
|
as of release 5.0.
|
|
|
|
resetPending (14) Card is awaiting reset following an
|
|
upgrade or downgrade activity switch.
|
|
The card software version is upgrade
|
|
or downgrade compatible but will be reset
|
|
in order to update it to match the active
|
|
CPM software. The value of
|
|
tmnxChassisUpdateWaitTime indicates the
|
|
how long the system will wait following
|
|
an upgrade or downgrade activity switch
|
|
before it resets IOM cards. This state
|
|
applies only to IOM cards. This
|
|
enumeration is no longer supported as of
|
|
release 5.0.
|
|
"
|
|
::= { tmnxHwEntry 16 }
|
|
|
|
tmnxHwTempSensor OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwTempSensor indicates whether or not this
|
|
hardware component contains a temperature sensor."
|
|
::= { tmnxHwEntry 17 }
|
|
|
|
tmnxHwTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature reading in degrees celsius from this hardware
|
|
component's temperature sensor. If this component does not contain
|
|
a temperature sensor, then the value -1 is returned."
|
|
::= { tmnxHwEntry 18 }
|
|
|
|
tmnxHwTempThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees celsius"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature threshold for this hardware component in degrees
|
|
celsius. When the value of tmnxHwTemperature raises above
|
|
tmnxHwTempThreshold, a 'temperature too high' event will
|
|
be generated."
|
|
::= { tmnxHwEntry 19 }
|
|
|
|
tmnxHwBootCodeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number of boot eprom on the card in this slot.
|
|
|
|
If no specific software program is associated with this hardware
|
|
component then this object will contain a zero length string."
|
|
::= { tmnxHwEntry 20 }
|
|
|
|
tmnxHwSoftwareCodeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The software product release version number for the software image
|
|
currently running on this IOM or CPM card.
|
|
|
|
If no specific software program is associated with this hardware
|
|
component then this object will contain a zero length string."
|
|
::= { tmnxHwEntry 21 }
|
|
|
|
tmnxHwSwLastBoot OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time the software running on this IOM or CPM card was
|
|
last rebooted.
|
|
|
|
If this row entry represents a standby CPM card, the date and time
|
|
indicated is when the standby completed its initial synchronization
|
|
process and became ready to take over in case the active card fails
|
|
or a manual switchover command is issued."
|
|
::= { tmnxHwEntry 22 }
|
|
|
|
tmnxHwSwState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
hwFailure (1),
|
|
swFailure (2),
|
|
hwInitting (3),
|
|
swDownloading (4),
|
|
swInitting (5),
|
|
swInitted (6),
|
|
swRunning (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The state of the software running on this IOM or CPM card.
|
|
|
|
The tmnxHwSwState object is obsolete. The Alcatel 7x50 platform
|
|
cannot distinguish software status separate from the hardware
|
|
status. Instead of using this object, additional operational
|
|
states have been added to tmnxHwOperState.
|
|
|
|
If no specific software program is associated with this hardware
|
|
component then this object will contain a zero."
|
|
::= { tmnxHwEntry 23 }
|
|
|
|
tmnxHwAlarmState OBJECT-TYPE
|
|
SYNTAX TmnxAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwAlarmState indicates the current alarm
|
|
state for this hardware component."
|
|
::= { tmnxHwEntry 24 }
|
|
|
|
tmnxHwLastAlarmEvent OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwLastAlarmEvent is an object identifier whose
|
|
object name and instance values point to the row entry in the
|
|
ALARM-MIB that contains the most recent alarm event associated with
|
|
this hardware component. If the tmnxHwAlarmState has a value of
|
|
'alarmCleared', the most recent alarm event will be in the
|
|
nlmAlarmClearedTable. If it has a value of 'alarmActive', the
|
|
entry pointed to is in the nlmAlarmActiveTable. If the value of
|
|
tmnxHwLastAlarmEvent is '0.0', then either there have not been any
|
|
alarm events associated with this chassis since the system was
|
|
last booted, or the last alarm event has aged out and its entry is
|
|
no longer available in the ALARM-MIB tables."
|
|
::= { tmnxHwEntry 25 }
|
|
|
|
tmnxHwClearAlarms OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this action variable causes all the active alarms associated
|
|
with this hardware component to be moved from the ALARM-MIB
|
|
nlmActiveAlarmTable to the nlmClearedAlarmTable. This action button
|
|
is primarily meant for use as a code development aid. This object may
|
|
be removed from the ALCATEL-IND1-TIMETRA-CHASSIS-MIB before product release."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxHwEntry 26 }
|
|
|
|
tmnxHwSwImageSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
primary (1),
|
|
secondary (2),
|
|
tertiary (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwSwImageSource indicates the location in the
|
|
Boot Options File (BOF) where the software image file was found
|
|
when the system last rebooted."
|
|
::= { tmnxHwEntry 27 }
|
|
|
|
tmnxHwMfgDeviations OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxHwMfgDeviations contains a record of changes done by the
|
|
manufacturing to the hardware or software and which is outside the
|
|
normal revision control process."
|
|
::= { tmnxHwEntry 28 }
|
|
|
|
tmnxHwBaseMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxHwBaseMacAddress contains the base MAC address of the hardware
|
|
component. It is applicable only if tmnxHwClass is of type 'chassis',
|
|
'ioModule', 'cpmModule' or 'mdaModule'."
|
|
::= { tmnxHwEntry 29 }
|
|
|
|
tmnxHwFailureReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxHwFailureReason indicates the reason why a hardware component
|
|
'failed' as indicated in tmnxHwOperState."
|
|
::= { tmnxHwEntry 30 }
|
|
|
|
--
|
|
-- Alcatel 7x50 SR series Hardware Components Containment Table
|
|
--
|
|
tmnxHwContainsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxHwContainsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxHwContainsTable shows the container/containee relationship
|
|
between entries in the tmnxHwTable. The hardware component
|
|
containment tree can be constructed from information in the
|
|
tmnxHwTable, but this table provides the information in a more
|
|
convenient format for the manager system to use."
|
|
::= { tmnxChassisObjs 9 }
|
|
|
|
tmnxHwContainsEntry OBJECT-TYPE
|
|
SYNTAX TmnxHwContainsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a single container/containee relationship.
|
|
Entries cannot be created and deleted via SNMP SET operations."
|
|
INDEX { tmnxHwIndex, tmnxHwContainedIndex }
|
|
::= { tmnxHwContainsTable 1 }
|
|
|
|
TmnxHwContainsEntry ::=
|
|
SEQUENCE {
|
|
tmnxHwContainedIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxHwContainedIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIndex for the contained hardware component."
|
|
::= { tmnxHwContainsEntry 1 }
|
|
|
|
--
|
|
-- Alcatel 7710 SR series Chassis Control Module (CCM) Table
|
|
--
|
|
|
|
tmnxCcmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCcmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about CCM."
|
|
::= { tmnxChassisObjs 10 }
|
|
|
|
tmnxCcmEntry OBJECT-TYPE
|
|
SYNTAX TmnxCcmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information regarding a CCM."
|
|
INDEX { tmnxChassisIndex, tmnxCcmIndex }
|
|
::= { tmnxCcmTable 1 }
|
|
|
|
TmnxCcmEntry ::=
|
|
SEQUENCE {
|
|
tmnxCcmIndex Unsigned32,
|
|
tmnxCcmOperStatus TmnxDeviceState,
|
|
tmnxCcmHwIndex TmnxHwIndex,
|
|
tmnxCcmEquippedType TmnxCcmType
|
|
}
|
|
|
|
tmnxCcmIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies a specific CCM instance in the
|
|
chassis."
|
|
::= { tmnxCcmEntry 1 }
|
|
|
|
tmnxCcmOperStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the CCM."
|
|
::= { tmnxCcmEntry 2 }
|
|
|
|
tmnxCcmHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcmHwIndex is the index into the tmnxHwTable
|
|
for the row entry that represents the hardware component information
|
|
for this CCM."
|
|
::= { tmnxCcmEntry 3 }
|
|
|
|
tmnxCcmEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxCcmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the CCM type that is physically
|
|
inserted into this chassis. There will not be more than one
|
|
bit set at a time in tmnxCcmEquippedType."
|
|
::= { tmnxCcmEntry 4 }
|
|
|
|
--
|
|
-- Chassis Control Module Type (CCM) Definition Table
|
|
--
|
|
tmnxCcmTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCcmTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The card type table has an entry for each Alcatel 7710 series
|
|
Chassis Control Module (CCM) model."
|
|
::= { tmnxChassisObjs 11 }
|
|
|
|
tmnxCcmTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxCcmTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7710 series CCM model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxCcmTypeIndex }
|
|
::= { tmnxCcmTypeTable 1 }
|
|
|
|
TmnxCcmTypeEntry ::=
|
|
SEQUENCE {
|
|
tmnxCcmTypeIndex TmnxCcmType,
|
|
tmnxCcmTypeName TNamedItemOrEmpty,
|
|
tmnxCcmTypeDescription TItemDescription,
|
|
tmnxCcmTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxCcmTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxCcmType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Alcatel
|
|
7710 series CCM model."
|
|
::= { tmnxCcmTypeEntry 1 }
|
|
|
|
tmnxCcmTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Alcatel
|
|
7710 series CCM model. This name string may be used in CLI
|
|
commands to specify a particular card model type."
|
|
::= { tmnxCcmTypeEntry 2 }
|
|
|
|
tmnxCcmTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Alcatel 7710 series CCM model."
|
|
::= { tmnxCcmTypeEntry 3 }
|
|
|
|
tmnxCcmTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxCcmTypeStatus has a value of 'true' it
|
|
indicates that this CCM is supported in this revision of the
|
|
management software. When it has a value of 'false' there is no
|
|
support."
|
|
::= { tmnxCcmTypeEntry 4 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- Alcatel 7x50 SR series Card Objects
|
|
--
|
|
|
|
--
|
|
-- IOM Card Table - The tmnxCardTable contains information
|
|
-- about the IOM cards in a chassis.
|
|
--
|
|
|
|
tmnxCardLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the tmnxCardTable was last changed."
|
|
::= { tmnxCardObjs 1 }
|
|
|
|
tmnxCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxCardTable has an entry for each IOM card slot in each
|
|
chassis in the TMNX system."
|
|
::= { tmnxCardObjs 2 }
|
|
|
|
tmnxCardEntry OBJECT-TYPE
|
|
SYNTAX TmnxCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an IOM card slot in a chassis in the
|
|
system. Entries cannot be created and deleted via SNMP SET
|
|
operations. When a tmnxChassisEntry is created, a tmnxCardEntry
|
|
is created for each IOM card slot in that chassis. Before a
|
|
tmnxChassisEntry can be deleted, each tmnxCardEntry for that
|
|
chassis must be in the proper state for removal."
|
|
INDEX { tmnxChassisIndex, tmnxCardSlotNum }
|
|
::= { tmnxCardTable 1 }
|
|
|
|
TmnxCardEntry ::=
|
|
SEQUENCE {
|
|
tmnxCardSlotNum TmnxSlotNum,
|
|
tmnxCardSupportedTypes TmnxCardType,
|
|
tmnxCardAllowedTypes TmnxCardType,
|
|
tmnxCardAssignedType TmnxCardType,
|
|
tmnxCardEquippedType TmnxCardType,
|
|
tmnxCardHwIndex TmnxHwIndex,
|
|
tmnxCardClockSource TItemDescription,
|
|
tmnxCardNumMdaSlots Unsigned32,
|
|
tmnxCardNumMdas Unsigned32,
|
|
tmnxCardReboot TmnxActionType,
|
|
tmnxCardMemorySize Unsigned32,
|
|
tmnxCardNamedPoolAdminMode TmnxAdminState,
|
|
tmnxCardNamedPoolOperMode TmnxAdminState
|
|
}
|
|
|
|
tmnxCardSlotNum OBJECT-TYPE
|
|
SYNTAX TmnxSlotNum
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this IOM slot within a chassis
|
|
in the system."
|
|
::= { tmnxCardEntry 1 }
|
|
|
|
tmnxCardSupportedTypes OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what card types can be physically
|
|
supported in this IOM slot in this chassis."
|
|
::= { tmnxCardEntry 2 }
|
|
|
|
tmnxCardAllowedTypes OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what IOM card types the administrator
|
|
has designated be allowed to be inserted into this slot.
|
|
If the slot has not-been pre-provisioned and a card that
|
|
does not match one of the allowed types is inserted into
|
|
this slot, a mis-match alarm will be raised. If a specific
|
|
value has not yet been SET by the manager, tmnxCardAllowedTypes
|
|
will return the same value to a GET request as
|
|
tmnxCardSupportedTypes.
|
|
|
|
The object was made obsolete in the 3.0 release."
|
|
::= { tmnxCardEntry 3 }
|
|
|
|
tmnxCardAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the administratively assigned
|
|
(pre-provisioned) IOM card type that should occupy this slot
|
|
in this chassis. If tmnxCardAssignedType has a value of
|
|
'unassigned', this slot has not yet been pre-provisioned.
|
|
There must not be more than one bit set at a time in
|
|
tmnxCardAssignedType."
|
|
DEFVAL { 1 }
|
|
::= { tmnxCardEntry 4 }
|
|
|
|
tmnxCardEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the IOM card type that is physically
|
|
inserted into this slot in this chassis. If the slot has been
|
|
pre-provisioned, tmnxCardAssignedType is not equal 'unassigned',
|
|
and the value of tmnxCardEquippedType is not the same as
|
|
tmnxCardAssignedType, a mis-match alarm will be raised. If the
|
|
slot has not been pre-provisioned, and the value of
|
|
tmnxCardEquippedType is not one of the allowed types as specified
|
|
by tmnxCardAllowedTypes, a mis-match alarm will be raised. There
|
|
will not be more than one bit set at a time in tmnxCardEquippedType.
|
|
A value of 0 indicates the IOM card type is not recognized by the
|
|
software."
|
|
::= { tmnxCardEntry 5 }
|
|
|
|
tmnxCardHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCardHwIndex is the index into the tmnxHwTable
|
|
for the row entry that represents the hardware component information
|
|
for this IOM card."
|
|
::= { tmnxCardEntry 6 }
|
|
|
|
tmnxCardClockSource OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock source used by the IOM card in this slot."
|
|
::= { tmnxCardEntry 10 }
|
|
|
|
tmnxCardNumMdaSlots OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Media Dependent Adapter (MDA) slots available on
|
|
this IOM card."
|
|
::= { tmnxCardEntry 11 }
|
|
|
|
tmnxCardNumMdas OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Media Dependent Adapters installed on this IOM card."
|
|
::= { tmnxCardEntry 12 }
|
|
|
|
tmnxCardReboot OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'doAction' causes the IOM card to execute
|
|
a soft-reboot."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxCardEntry 13 }
|
|
|
|
tmnxCardMemorySize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Mega-bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCardMemorySize indicates the amount of
|
|
memory, in mega-bytes, populated on this IOM card."
|
|
::= { tmnxCardEntry 14 }
|
|
|
|
tmnxCardNamedPoolAdminMode OBJECT-TYPE
|
|
SYNTAX TmnxAdminState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCardNamedPoolAdminMode specifies whether or
|
|
not an IOM is provisioned for the configuration of named pools. If
|
|
the value of tmnxCardNamedPoolAdminMode is 'inService(2)', the
|
|
system will change the way default pools are created and allow for
|
|
the creation of MDA and port level named buffer pools. If the value
|
|
of tmnxCardNamedPoolAdminMode is 'outOfService(3)', the system will
|
|
not create per port pools, instead a default network and access pool
|
|
is created for ingress and egress and is shared by queues on all
|
|
ports. This object is used in conjunction with
|
|
tmnxCardNamedPoolOperMode."
|
|
DEFVAL { outOfService }
|
|
::= { tmnxCardEntry 15 }
|
|
|
|
tmnxCardNamedPoolOperMode OBJECT-TYPE
|
|
SYNTAX TmnxAdminState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCardNamedPoolOperMode specifies whether or
|
|
not an IOM provisioned with tmnxCardNamedPoolAdminMode to a
|
|
value of 'inService(2)' will activly use named pools or not.
|
|
A value of 'outOfService(3) means that the named pool configurations
|
|
will not be downloaded to the IOM until after a reset of the IOM
|
|
is performed. A value of 'inService(2)' means that the named pool
|
|
configurations are programmed by the IOM. On systems using a
|
|
separate CPM and IOM combination the value of tmnxCardNamedPoolOperMode
|
|
and tmnxCardNamedPoolAdminMode will always be in sync due to a
|
|
mandatory reboot of the IOM. On systems using a combined image (CFM)
|
|
these values will be out-of-sync until the chassis is rebooted."
|
|
DEFVAL { outOfService }
|
|
::= { tmnxCardEntry 16 }
|
|
|
|
|
|
--
|
|
-- CPM Card Table - The Chassis Process Manager card table contains
|
|
-- the information about CPM cards or modules in a chassis.
|
|
--
|
|
|
|
tmnxCpmCardLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the tmnxCpmCardTable was last changed."
|
|
::= { tmnxCardObjs 3 }
|
|
|
|
tmnxCpmCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCpmCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxCpmCardTable has an entry for each CPM card or module in
|
|
each chassis in the TMNX system."
|
|
::= { tmnxCardObjs 4 }
|
|
|
|
tmnxCpmCardEntry OBJECT-TYPE
|
|
SYNTAX TmnxCpmCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a CPM card or module in a chassis in the
|
|
system. Entries cannot be created and deleted via SNMP SET
|
|
operations. When a tmnxChassisEntry is created, a tmnxCpmCardEntry
|
|
is created for each CPM card or module in that chassis. Before a
|
|
tmnxChassisEntry can be deleted, each tmnxCpmCardEntry for that
|
|
chassis must be in the proper state for removal."
|
|
INDEX { tmnxChassisIndex, tmnxCpmCardSlotNum, tmnxCpmCardNum }
|
|
::= { tmnxCpmCardTable 1 }
|
|
|
|
TmnxCpmCardEntry ::=
|
|
SEQUENCE {
|
|
tmnxCpmCardSlotNum TmnxSlotNum,
|
|
tmnxCpmCardNum Unsigned32,
|
|
tmnxCpmCardSupportedTypes TmnxCardType,
|
|
tmnxCpmCardAllowedTypes TmnxCardType,
|
|
tmnxCpmCardAssignedType TmnxCardType,
|
|
tmnxCpmCardEquippedType TmnxCardType,
|
|
tmnxCpmCardHwIndex TmnxHwIndex,
|
|
tmnxCpmCardBootOptionVersion TItemDescription,
|
|
tmnxCpmCardBootOptionLastModified DateAndTime,
|
|
tmnxCpmCardConfigBootedVersion TItemDescription,
|
|
tmnxCpmCardIndexBootedVersion TItemDescription,
|
|
tmnxCpmCardConfigLastModified DateAndTime,
|
|
tmnxCpmCardConfigLastSaved DateAndTime,
|
|
tmnxCpmCardRedundant INTEGER,
|
|
tmnxCpmCardClockSource TItemDescription,
|
|
tmnxCpmCardNumCpus Unsigned32,
|
|
tmnxCpmCardCpuType INTEGER,
|
|
tmnxCpmCardMemorySize Unsigned32,
|
|
tmnxCpmCardSwitchToRedundantCard TmnxActionType,
|
|
tmnxCpmCardReboot TmnxActionType,
|
|
tmnxCpmCardRereadBootOptions TmnxActionType,
|
|
tmnxCpmCardConfigFileLastBooted DisplayString,
|
|
tmnxCpmCardConfigFileLastSaved DisplayString,
|
|
tmnxCpmCardConfigFileLastBootedHeader OCTET STRING,
|
|
tmnxCpmCardIndexFileLastBootedHeader OCTET STRING,
|
|
tmnxCpmCardBootOptionSource DisplayString,
|
|
tmnxCpmCardConfigSource INTEGER,
|
|
tmnxCpmCardBootOptionLastSaved DateAndTime,
|
|
tmnxCpmCardMasterSlaveRefState INTEGER
|
|
}
|
|
|
|
tmnxCpmCardSlotNum OBJECT-TYPE
|
|
SYNTAX TmnxSlotNum
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this slot within a chassis in
|
|
the system. Depending upon the value of tmnxChassisType, this may
|
|
represent a fabric slot or a regular card slot. If this CPM module
|
|
resides on a fabric card, tmnxCpmCardSlotNum has the value the
|
|
corresponding tmnxFabricSlotNum. If this is a CPM module on a
|
|
fabric card, tmnxCpmCardSlotNum is the fabric slot number in the
|
|
chassis where this CPM module is located. Else if this is a
|
|
CPM card, tmnxCpmCardSlotNum is a regular card slot number."
|
|
::= { tmnxCpmCardEntry 1 }
|
|
|
|
tmnxCpmCardNum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this CPM module within a
|
|
specific card slot within a chassis in the system."
|
|
::= { tmnxCpmCardEntry 2 }
|
|
|
|
tmnxCpmCardSupportedTypes OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what CPM card types can be physically
|
|
supported in this slot in this chassis."
|
|
::= { tmnxCpmCardEntry 3 }
|
|
|
|
tmnxCpmCardAllowedTypes OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what CPM card types the administrator
|
|
has designated be allowed to be inserted into this slot. If the
|
|
slot has not-been pre-provisioned and a card that does not match
|
|
one of the allowed types is inserted into this slot, a mis-match
|
|
alarm will be raised. If a specific value has not yet been SET by
|
|
the manager, tmnxCpmCardAllowedTypes will return the same value to
|
|
a GET request as tmnxCpmCardSupportedTypes.
|
|
|
|
The object was made obsolete in the 3.0 release."
|
|
::= { tmnxCpmCardEntry 4 }
|
|
|
|
tmnxCpmCardAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the administratively assigned
|
|
(pre-provisioned) CPM card type that should occupy this slot
|
|
in this chassis. If tmnxCpmCardAssignedType has a value of
|
|
'unassigned', this slot has not yet been pre-provisioned.
|
|
There must not be more than one bit set at a time in
|
|
tmnxCpmCardAssignedType."
|
|
DEFVAL { 1 }
|
|
::= { tmnxCpmCardEntry 5 }
|
|
|
|
tmnxCpmCardEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the CPM card type that is physically
|
|
inserted into this slot in this chassis. If the slot has been
|
|
pre-provisioned, tmnxCpmCardAssignedType is not equal 'unassigned',
|
|
and the value of tmnxCpmCardEquippedType is not the same as
|
|
tmnxCpmCardAssignedType, a mis-match alarm will be raised.
|
|
|
|
If the slot has not been pre-provisioned, and the value of
|
|
tmnxCpmCardEquippedType is not one of the allowed types as specified
|
|
by tmnxCpmCardAllowedTypes, a mis-match alarm will be raised.
|
|
There will not be more than one bit set at a time in
|
|
tmnxCpmCardEquippedType."
|
|
::= { tmnxCpmCardEntry 6 }
|
|
|
|
tmnxCpmCardHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmCardHwIndex is the index into the tmnxHwTable
|
|
for the row entry that represents the hardware component information
|
|
for this CPM card or module."
|
|
::= { tmnxCpmCardEntry 7 }
|
|
|
|
tmnxCpmCardBootOptionVersion OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number of boot option file (BOF) read by the CPM card in
|
|
this slot."
|
|
::= { tmnxCpmCardEntry 8 }
|
|
|
|
tmnxCpmCardBootOptionLastModified OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time the boot options file (BOF) for this card was last
|
|
modified. If tmnxCpmCardBootOptionLastModified is more recent than
|
|
tmnxHwSwLastBoot, the boot options file has been edited since
|
|
the software was booted and different software images or configuration
|
|
will likely be used when this card is next rebooted."
|
|
::= { tmnxCpmCardEntry 9 }
|
|
|
|
tmnxCpmCardConfigBootedVersion OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the configuration file read when this CPM card was
|
|
last rebooted."
|
|
::= { tmnxCpmCardEntry 10 }
|
|
|
|
tmnxCpmCardIndexBootedVersion OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the index file read when this CPM card was
|
|
last rebooted."
|
|
::= { tmnxCpmCardEntry 11 }
|
|
|
|
tmnxCpmCardConfigLastModified OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time the running configuration was last modified.
|
|
If tmnxCpmCardConfigLastModified is more recent than
|
|
tmnxHwSwLastBoot, the current configuration may be different
|
|
than that in the configuration file read upon system initialization."
|
|
::= { tmnxCpmCardEntry 12 }
|
|
|
|
tmnxCpmCardConfigLastSaved OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time the current configuration was last saved.
|
|
If tmnxCpmCardConfigLastSaved is more recent the value of
|
|
tmnxHwSwLastBoot, the initial configuration is likely to
|
|
be different the next time the system is rebooted."
|
|
::= { tmnxCpmCardEntry 13 }
|
|
|
|
tmnxCpmCardRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
singleton (1),
|
|
redundantActive (2),
|
|
redundantStandby (3),
|
|
redundantSplit (4),
|
|
redundantDisabled (5),
|
|
redundantSynching (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates if the CPM card is standalone or part
|
|
of a pair of redundant cards. If 'redundantDisabled',
|
|
tmnxHwOperState indicates the specific reason why this
|
|
redundant CPM card is not available.
|
|
|
|
Note that the 'redudantSplit' option is not implemented."
|
|
::= { tmnxCpmCardEntry 14 }
|
|
|
|
tmnxCpmCardClockSource OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The clock source used by the CPM card in this slot."
|
|
::= { tmnxCpmCardEntry 15 }
|
|
|
|
tmnxCpmCardNumCpus OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmCardNumCpus indicates the number of CPU chips
|
|
populated on this CPM module."
|
|
::= { tmnxCpmCardEntry 16 }
|
|
|
|
tmnxCpmCardCpuType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
mips (2),
|
|
pentium-pc (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmCardCpuType indicates the type of CPU chips
|
|
populated on this CPM module."
|
|
::= { tmnxCpmCardEntry 17 }
|
|
|
|
tmnxCpmCardMemorySize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Mega-bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmCardMemorySize indicates the amount of
|
|
memory, in mega-bytes, populated on this CPM module."
|
|
::= { tmnxCpmCardEntry 18 }
|
|
|
|
tmnxCpmCardSwitchToRedundantCard OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to doAction causes the switchover to the
|
|
redundant CPM card."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxCpmCardEntry 19 }
|
|
|
|
tmnxCpmCardReboot OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'doAction' causes the CPM card to execute
|
|
a soft-reboot."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxCpmCardEntry 20 }
|
|
|
|
tmnxCpmCardRereadBootOptions OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'doAction' causes the Boot Options File
|
|
(BOF) to be reread and applied."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxCpmCardEntry 21 }
|
|
|
|
tmnxCpmCardConfigFileLastBooted OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxCpmCardConfigFileLastBooted indicates the location and name of
|
|
the configuration file from which the system last rebooted."
|
|
::= { tmnxCpmCardEntry 22 }
|
|
|
|
tmnxCpmCardConfigFileLastSaved OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxCpmCardConfigFileLastSaved indicates the location and name of the
|
|
file to which the configuration was last saved."
|
|
::= { tmnxCpmCardEntry 23 }
|
|
|
|
tmnxCpmCardConfigFileLastBootedHeader OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxCpmCardConfigFileLastBootedHeader contains the header
|
|
of the configuration file from which the system last rebooted."
|
|
::= { tmnxCpmCardEntry 24 }
|
|
|
|
tmnxCpmCardIndexFileLastBootedHeader OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxCpmCardIndexFileLastBootedHeader contains the header
|
|
of the index file from which the system last rebooted."
|
|
::= { tmnxCpmCardEntry 25 }
|
|
|
|
tmnxCpmCardBootOptionSource OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxCpmCardBootOptionSource indicates the compact flash slot where the
|
|
Boot Options File (BOF) file was found when the system last rebooted.
|
|
For example, if the BOF file was found on compact flash slot 1, the
|
|
value of this variable will be 'cf1:'"
|
|
::= { tmnxCpmCardEntry 26 }
|
|
|
|
tmnxCpmCardConfigSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (0),
|
|
primary (1),
|
|
secondary (2),
|
|
tertiary (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmCardConfigSource indicates the location
|
|
in the Boot Options File(BOF) where the configuration file was
|
|
found when the system last rebooted."
|
|
::= { tmnxCpmCardEntry 27 }
|
|
|
|
tmnxCpmCardBootOptionLastSaved OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time the boot options file (BOF) was last saved.
|
|
If tmnxCpmCardBootOptionLastSaved is more recent than the value
|
|
of tmnxHwSwLastBoot, the boot options file has been edited
|
|
since the software was booted and different software images or
|
|
configuration will likely be used when this card is next rebooted."
|
|
::= { tmnxCpmCardEntry 28 }
|
|
|
|
tmnxCpmCardMasterSlaveRefState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
primaryRef (1),
|
|
secondaryRef (2),
|
|
notInitialized (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current Master/Slave clocking reference designation.
|
|
|
|
primaryRef Indicates this card is designated as the primary
|
|
clocking reference in a redundant system.
|
|
secondaryRef Indicates this card is designated as the secondary
|
|
clocking reference in a redundant system.
|
|
notInitialized Indicates the clock is not initialized.
|
|
"
|
|
::= { tmnxCpmCardEntry 30 }
|
|
|
|
--
|
|
-- Fabric Card Table - The fabric card table contains information about
|
|
-- the fabric cards in a chassis.
|
|
--
|
|
|
|
tmnxFabricLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the tmnxFabricTable was last changed."
|
|
::= { tmnxCardObjs 5 }
|
|
|
|
tmnxFabricTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxFabricEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxFabricTable has an entry for each fabric card slot in
|
|
each chassis in the TMNX system."
|
|
::= { tmnxCardObjs 6 }
|
|
|
|
tmnxFabricEntry OBJECT-TYPE
|
|
SYNTAX TmnxFabricEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a fabric card slot in a chassis in
|
|
the system. Entries cannot be created and deleted via
|
|
SNMP SET operations. When a tmnxChassisEntry is created,
|
|
a tmnxFabricEntry is created for each fabric card slot in that
|
|
chassis. Before a tmnxChassisEntry can be deleted, each
|
|
tmnxFabricEntry for that chassis must be in the proper state
|
|
for removal."
|
|
INDEX { tmnxChassisIndex, tmnxFabricSlotNum }
|
|
::= { tmnxFabricTable 1 }
|
|
|
|
TmnxFabricEntry ::=
|
|
SEQUENCE {
|
|
tmnxFabricSlotNum Unsigned32,
|
|
tmnxFabricAssignedType TmnxCardType,
|
|
tmnxFabricEquippedType TmnxCardType,
|
|
tmnxFabricHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxFabricSlotNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this fabric slot within a
|
|
chassis in the system. The CPM cards and IOM cards cannot be
|
|
physically inserted into the switch fabric card slots. In
|
|
some models, the CPM is not a separate card, but rather a
|
|
module on a Fabric card."
|
|
::= { tmnxFabricEntry 1 }
|
|
|
|
tmnxFabricAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administratively assigned switch fabric card type that
|
|
should occupy this fabric slot in this chassis."
|
|
DEFVAL { 2 }
|
|
::= { tmnxFabricEntry 2 }
|
|
|
|
tmnxFabricEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switch fabric card type that is physically inserted into
|
|
this slot in this chassis."
|
|
::= { tmnxFabricEntry 3 }
|
|
|
|
tmnxFabricHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIndex is the index into the tmnxHwTable to
|
|
locate the row entry that represents the hardware component
|
|
information for this fabric card."
|
|
::= { tmnxFabricEntry 4 }
|
|
|
|
|
|
--
|
|
-- Flash Drive Table
|
|
--
|
|
|
|
tmnxCpmFlashTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCpmFlashEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about Flash devices on a CPM card."
|
|
::= { tmnxCardObjs 7 }
|
|
|
|
tmnxCpmFlashEntry OBJECT-TYPE
|
|
SYNTAX TmnxCpmFlashEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information regarding a CPM card's flash unit."
|
|
INDEX { tmnxChassisIndex, tmnxCardSlotNum, tmnxCpmFlashId }
|
|
::= { tmnxCpmFlashTable 1 }
|
|
|
|
TmnxCpmFlashEntry ::=
|
|
SEQUENCE {
|
|
tmnxCpmFlashId Unsigned32,
|
|
tmnxCpmFlashOperStatus TmnxDeviceState,
|
|
tmnxCpmFlashSerialNumber TItemDescription,
|
|
tmnxCpmFlashFirmwareRevision TItemDescription,
|
|
tmnxCpmFlashModelNumber TItemDescription,
|
|
tmnxCpmFlashCapacity Unsigned32,
|
|
tmnxCpmFlashUsed Unsigned32,
|
|
tmnxCpmFlashHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxCpmFlashId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..32)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique identifier index for a flash device on a CPM card."
|
|
::= { tmnxCpmFlashEntry 1 }
|
|
|
|
tmnxCpmFlashOperStatus OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of this flash unit on this CPM card."
|
|
::= { tmnxCpmFlashEntry 2 }
|
|
|
|
tmnxCpmFlashSerialNumber OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number for this flash unit on this CPM card."
|
|
::= { tmnxCpmFlashEntry 3 }
|
|
|
|
tmnxCpmFlashFirmwareRevision OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware revision number for this flash unit on this CPM card."
|
|
::= { tmnxCpmFlashEntry 4 }
|
|
|
|
tmnxCpmFlashModelNumber OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The model number for this flash unit on this CPM card."
|
|
::= { tmnxCpmFlashEntry 5 }
|
|
|
|
tmnxCpmFlashCapacity OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "sectors"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmFlashCapacity indicates the maximum size
|
|
of this flash unit in 512-byte sectors."
|
|
::= { tmnxCpmFlashEntry 6 }
|
|
|
|
tmnxCpmFlashUsed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "sectors"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCpmFlashUsed indicates the amount used, in
|
|
512-byte sectors, of this flash unit's total capacity."
|
|
::= { tmnxCpmFlashEntry 7 }
|
|
|
|
tmnxCpmFlashHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIndex is the index into the tmnxHwTable for
|
|
the row entry that represents the hardware component information
|
|
for this flash unit."
|
|
::= { tmnxCpmFlashEntry 8 }
|
|
|
|
|
|
--
|
|
-- MDA table
|
|
--
|
|
tmnxMDATable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxMDAEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxMDATable has an entry for each MDA slot in each IOM
|
|
card in this chassis in the TMNX system."
|
|
::= { tmnxCardObjs 8 }
|
|
|
|
tmnxMDAEntry OBJECT-TYPE
|
|
SYNTAX TmnxMDAEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a MDA slot in an IOM card in a
|
|
chassis in the system. Entries cannot be created and
|
|
deleted via SNMP SET operations. When a tmnxCardEntry
|
|
has tmnxCardAssignedType or tmnxCardEquippedType equal to
|
|
an IOM card type that supports MDA slots, a tmnxMDAEntry is
|
|
created by the agent for each MDA slot on that IOM card.
|
|
Before a tmnxCardEntry can be deleted, each tmnxMDAEntry for
|
|
that card must be in the proper state for removal."
|
|
INDEX { tmnxChassisIndex, tmnxCardSlotNum, tmnxMDASlotNum }
|
|
::= { tmnxMDATable 1 }
|
|
|
|
TmnxMDAEntry ::=
|
|
SEQUENCE {
|
|
tmnxMDASlotNum Unsigned32,
|
|
tmnxMDASupportedTypes TmnxMDASuppType,
|
|
tmnxMDAAllowedTypes TmnxMdaType,
|
|
tmnxMDAAssignedType TmnxMdaType,
|
|
tmnxMDAEquippedType TmnxMdaType,
|
|
tmnxMDAHwIndex TmnxHwIndex,
|
|
tmnxMDAMaxPorts INTEGER,
|
|
tmnxMDAEquippedPorts Unsigned32,
|
|
tmnxMDATxTimingSelected INTEGER,
|
|
tmnxMDASyncIfTimingStatus INTEGER,
|
|
tmnxMDANetworkIngQueues TNamedItem,
|
|
tmnxMDACapabilities BITS,
|
|
tmnxMDAMinChannelization TmnxMDAChanType,
|
|
tmnxMDAMaxChannelization TmnxMDAChanType,
|
|
tmnxMDAMaxChannels Unsigned32,
|
|
tmnxMDAChannelsInUse Unsigned32,
|
|
tmnxMDACcagId TmnxCcagId,
|
|
tmnxMDAReboot TmnxActionType,
|
|
tmnxMDAHiBwMcastSource TruthValue,
|
|
tmnxMDAHiBwMcastAlarm TruthValue,
|
|
tmnxMDAHiBwMcastTapCount Gauge32,
|
|
tmnxMDAHiBwMcastGroup Unsigned32,
|
|
tmnxMDAClockMode INTEGER,
|
|
tmnxMDADiffTimestampFreq Unsigned32,
|
|
tmnxMDAMcPathMgmtBwPlcyName TNamedItem,
|
|
tmnxMDAMcPathMgmtPriPathLimit Unsigned32,
|
|
tmnxMDAMcPathMgmtSecPathLimit Unsigned32,
|
|
tmnxMDAMcPathMgmtAncPathLimit Unsigned32,
|
|
tmnxMDAMcPathMgmtAdminState TmnxAdminState,
|
|
tmnxMDAIngNamedPoolPolicy TNamedItemOrEmpty,
|
|
tmnxMDAEgrNamedPoolPolicy TNamedItemOrEmpty,
|
|
tmnxMDAMcPathMgmtPriInUseBw Gauge32,
|
|
tmnxMDAMcPathMgmtSecInUseBw Gauge32,
|
|
tmnxMDAMcPathMgmtAncInUseBw Gauge32,
|
|
tmnxMDAMcPathMgmtBlkHoleInUseBw Gauge32
|
|
}
|
|
|
|
tmnxMDASlotNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this MDA slot within a
|
|
specific IOM card in the system. Rows with a tmnxMDASlotNum
|
|
value of zero (0) represent the special case of an IOM card
|
|
without MDA slots but that instead has its ports directly
|
|
on the IOM card itself. In that case, there should be only
|
|
that one row entry in the tmnxMDATable for that IOM card."
|
|
::= { tmnxMDAEntry 1 }
|
|
|
|
tmnxMDASupportedTypes OBJECT-TYPE
|
|
SYNTAX TmnxMDASuppType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what MDA card types can be physically
|
|
supported in this slot in this chassis."
|
|
::= { tmnxMDAEntry 2 }
|
|
|
|
tmnxMDAAllowedTypes OBJECT-TYPE
|
|
SYNTAX TmnxMdaType
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"An integer that specified what MDA card types the administrator
|
|
has designated be allowed to be inserted into this slot.
|
|
If the slot has not-been pre-provisioned and a MDA card that
|
|
does not match one of the allowed types is inserted into
|
|
this slot, a mis-match alarm will be raised.
|
|
|
|
The object was made obsolete in the 3.0 release."
|
|
::= { tmnxMDAEntry 3 }
|
|
|
|
tmnxMDAAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxMdaType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the administratively assigned
|
|
(pre-provisioned) MDA card type that should occupy this slot in
|
|
this chassis. If tmnxMDAAssignedType has a value of
|
|
'unassigned', this slot has not yet been pre-provisioned."
|
|
DEFVAL { 1 }
|
|
::= { tmnxMDAEntry 4 }
|
|
|
|
tmnxMDAEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxMdaType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer that indicates the MDA card type that is physically
|
|
inserted into this slot in this chassis. If the slot has been
|
|
pre-provisioned, tmnxMDAAssignedType is not equal 'unassigned',
|
|
and the value of tmnxMDAEquippedType is not the same as
|
|
tmnxMDAAssignedType, a mis-match alarm will be raised.
|
|
A value of 0 indicates the equipped MDA is not supported by
|
|
this software release."
|
|
::= { tmnxMDAEntry 5 }
|
|
|
|
tmnxMDAHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxHwIndex is the index into the tmnxHwTable for
|
|
the row entry that represents the hardware component information
|
|
for this MDA card."
|
|
::= { tmnxMDAEntry 6 }
|
|
|
|
tmnxMDAMaxPorts OBJECT-TYPE
|
|
SYNTAX INTEGER (0..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of ports that can be equipped on this MDA card."
|
|
::= { tmnxMDAEntry 7 }
|
|
|
|
tmnxMDAEquippedPorts OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAEquippedPorts indicates the number of ports
|
|
equipped on this MDA card."
|
|
::= { tmnxMDAEntry 8 }
|
|
|
|
tmnxMDATxTimingSelected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
cpm-card-A(1),
|
|
cpm-card-B(2),
|
|
local(3),
|
|
holdover(4),
|
|
not-applicable(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit timing method which is presently selected and being
|
|
used by this MDA.
|
|
tmnxMDATxTimingSelected will be set to 'not-applicable' if this MDA
|
|
does not use the transmit timing subsystem."
|
|
::= { tmnxMDAEntry 10 }
|
|
|
|
tmnxMDASyncIfTimingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
qualified(1),
|
|
not-qualified(2),
|
|
not-applicable(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the synchronous equipment timing subsystem.
|
|
If the tmnxSyncIfTimingRef1Qualified and tmnxSyncIfTimingRef2Qualified
|
|
are both set to 'not-qualified, then tmnxMDASyncIfTimingStatus is set
|
|
to 'not-qualified'. If any of the timing references is in use, then
|
|
tmnxMDASyncIfTimingStatus is set to 'qualified'.
|
|
tmnxMDASyncIfTimingStatus will be set to 'not-applicable' if this MDA
|
|
does not use the transmit timing subsystem."
|
|
::= { tmnxMDAEntry 11 }
|
|
|
|
tmnxMDANetworkIngQueues OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the network queue policy being used for this object to
|
|
define the queueing structure for this object."
|
|
DEFVAL { "default" }
|
|
::= { tmnxMDAEntry 12 }
|
|
|
|
tmnxMDACapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
isEthernet(0),
|
|
isSonet(1),
|
|
isTDM(2),
|
|
supportsPPP(3),
|
|
supportsFR(4),
|
|
supportsATM(5),
|
|
supportscHDLC(6),
|
|
isCMA(7),
|
|
supportsCEM(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxMDACapabilities indicates the capabilities of this MDA.
|
|
It identifies the type of MDA and the protocols that can run on it."
|
|
::= { tmnxMDAEntry 13 }
|
|
|
|
tmnxMDAMinChannelization OBJECT-TYPE
|
|
SYNTAX TmnxMDAChanType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxMDAMinChannelization indicates the minimum size of the channel that
|
|
can exist on this MDA."
|
|
::= { tmnxMDAEntry 14 }
|
|
|
|
tmnxMDAMaxChannelization OBJECT-TYPE
|
|
SYNTAX TmnxMDAChanType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxMDAMaxChannelization indicates the maximum size of the channel that
|
|
can exist on this MDA."
|
|
::= { tmnxMDAEntry 15 }
|
|
|
|
tmnxMDAMaxChannels OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxMDAMaxChannels is applicable for SONET and TDM MDAs only. It
|
|
indicates the total number of leaf SONET paths, TDM channels
|
|
and bundles on the MDA that may be configured to pass traffic."
|
|
::= { tmnxMDAEntry 16 }
|
|
|
|
tmnxMDAChannelsInUse OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxMDAChannelsInUse is applicable for SONET and TDM MDAs only. It
|
|
indicates the total number of leaf SONET paths, TDM channels and
|
|
bundles on the MDA which are in use. A leaf SONET path or TDM
|
|
channel which is currently capable of passing traffic is considered
|
|
to be in use. Also, a SONET path or TDM channel which is
|
|
channelized and has no subchannels capable of passing traffic
|
|
is considered to be in use. A SONET path or TDM channel which is
|
|
channelized and has one or more subchannels capable of passing
|
|
traffic is not considered to be in use, although the subchannels
|
|
themselves are considered to be in use. A bundle is considered to
|
|
be a channel in use as are each of its members since they are TDM
|
|
channels capable of passing traffic."
|
|
::= { tmnxMDAEntry 17 }
|
|
|
|
tmnxMDACcagId OBJECT-TYPE
|
|
SYNTAX TmnxCcagId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxMDAAssignedType has a value of 'cca' , the value of
|
|
tmnxMDACcagId specifies the Cross Connect Aggregation Group (CCAG)
|
|
entry this MDA is provisioned on. If this entry does not represent
|
|
a 'cca' MDA or is not associated with a CCAG, tmnxMDACcagId
|
|
has a value of zero. "
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 18 }
|
|
|
|
tmnxMDAReboot OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this variable to 'doAction' causes the MDA to execute
|
|
a soft-reboot."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxMDAEntry 19 }
|
|
|
|
tmnxMDAHiBwMcastSource OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAHiBwMcastSource specifies if this MDA should
|
|
attempt to allocate separate fabric planes to allocate high bandwidth
|
|
multicast traffic taps.
|
|
|
|
tmnxMDAHiBwMcastGroup must be set in the same SNMP request PDU with
|
|
tmnxMDAHiBwMcastSource or an 'inconsistentValue' error will be
|
|
returned."
|
|
DEFVAL { false }
|
|
::= { tmnxMDAEntry 20 }
|
|
|
|
tmnxMDAHiBwMcastAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAHiBwMcastAlarm specifies if a
|
|
tmnxChassisHiBwMcastAlarm alarm is raised if there are more than
|
|
one high bandwidth multicast traffic taps sharing a plane."
|
|
DEFVAL { true }
|
|
::= { tmnxMDAEntry 21 }
|
|
|
|
tmnxMDAHiBwMcastTapCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAHiBwMcastTapCount indicates the number of high
|
|
bandwidth multicast traffic taps on this MDA."
|
|
::= { tmnxMDAEntry 22 }
|
|
|
|
tmnxMDAHiBwMcastGroup OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..32)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAHiBwMcastGroup specifies the group of high
|
|
bandwidth multicast traffic taps to which this tap belongs.
|
|
|
|
A value of '0' specifies that this tap is not a member of any High
|
|
Bandwidth Multicast group.
|
|
|
|
On an IOM of type 'iom-10g', the value of tmnxMDAHiBwMcastGroup
|
|
should be the same as the value of tmnxMDAHiBwMcastGroup set on the
|
|
other MDA residing on the IOM if the tmnxMDAHiBwMcastSource is set
|
|
to 'true'. Attempt to set to different values will result in an
|
|
'inconsistentValue' error.
|
|
|
|
tmnxMDAHiBwMcastGroup must be set in the same SNMP request PDU with
|
|
tmnxMDAHiBwMcastSource or an 'inconsistentValue' error will be
|
|
returned."
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 23 }
|
|
|
|
tmnxMDAClockMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (0),
|
|
adaptive (1),
|
|
differential (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAClockMode specifies the clock mode
|
|
of the MDA.
|
|
|
|
notApplicable - The MDA does not support any clock modes or domains.
|
|
adaptive - The MDA is in 'adaptive' clock mode. This allows
|
|
adaptive clock domains to be created.
|
|
differential - The MDA is in 'differential clock mode. This allows
|
|
differential clock domains to be created.
|
|
|
|
The value of tmnxMDAClockMode can be changed when there are no ports
|
|
created on the MDA. If there are ports created, a shutdown of the
|
|
MDA is required in order to change the value."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxMDAEntry 24 }
|
|
|
|
tmnxMDADiffTimestampFreq OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0|19440|77760|103680)
|
|
UNITS "kilohertz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDADiffTimestampFreq specifies the differential
|
|
timestamp frequency of the differential clock on the MDA.
|
|
|
|
The value must be a multiple of 8 KHz.
|
|
|
|
This value can only be changed if the value of tmnxMDAClockMode is
|
|
'differential (2)' and there are no ports created on the MDA. If
|
|
there are ports created, a shutdown of the MDA is required in order
|
|
to change the value.
|
|
|
|
If the value of tmnxMDAClockMode is 'differential (2) then the default
|
|
is 103,680 KHz.
|
|
If the value of tmnxMDAClockMode is not 'differential (2)' then
|
|
this value is 0 KHz and cannot be changed."
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 25 }
|
|
|
|
tmnxMDAMcPathMgmtBwPlcyName OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtBwPlcyName specifies the multicast policy
|
|
name configured on the MDA."
|
|
DEFVAL { "default" }
|
|
::= { tmnxMDAEntry 27 }
|
|
|
|
tmnxMDAMcPathMgmtPriPathLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0|1..2000)
|
|
UNITS "mega-bits-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtPriPathLimit specifies the primary path
|
|
limit for the MDA."
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 28 }
|
|
|
|
tmnxMDAMcPathMgmtSecPathLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0|1..2000)
|
|
UNITS "mega-bits-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtSecPathLimit specifies the secondary path
|
|
limit for the MDA."
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 29 }
|
|
|
|
tmnxMDAMcPathMgmtAncPathLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0|1..5000)
|
|
UNITS "mega-bits-per-second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtAncPathLimit specifies the ancillary path
|
|
limit for the MDA."
|
|
DEFVAL { 0 }
|
|
::= { tmnxMDAEntry 30 }
|
|
|
|
tmnxMDAMcPathMgmtAdminState OBJECT-TYPE
|
|
SYNTAX TmnxAdminState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtAdminState specifies administrative state
|
|
of this multicast path on the MDA."
|
|
DEFVAL { outOfService }
|
|
::= { tmnxMDAEntry 31 }
|
|
|
|
tmnxMDAIngNamedPoolPolicy OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAIngNamedPoolPolicy specifies a named pool
|
|
policy associated with an MDA ingress context. The policy
|
|
governs the way named pools are created at the MDA level."
|
|
DEFVAL { ''H }
|
|
::= { tmnxMDAEntry 32 }
|
|
|
|
tmnxMDAEgrNamedPoolPolicy OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAEgrNamedPoolPolicy specifies a named pool
|
|
policy associated with an MDA egress context. The policy
|
|
governs the way named pools are created at the MDA level."
|
|
DEFVAL { ''H }
|
|
::= { tmnxMDAEntry 33 }
|
|
|
|
tmnxMDAMcPathMgmtPriInUseBw OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtPriInUseBw indicates the in use
|
|
ingress multicast bandwidth for the primary forwarding path."
|
|
::= { tmnxMDAEntry 36 }
|
|
|
|
tmnxMDAMcPathMgmtSecInUseBw OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtSecInUseBw indicates the in use
|
|
ingress multicast bandwidth for the secondary forwarding path."
|
|
::= { tmnxMDAEntry 37 }
|
|
|
|
tmnxMDAMcPathMgmtAncInUseBw OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtAncInUseBw indicates the in use
|
|
ingress multicast bandwidth for the ancillary forwarding path."
|
|
::= { tmnxMDAEntry 38 }
|
|
|
|
tmnxMDAMcPathMgmtBlkHoleInUseBw OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMDAMcPathMgmtBlkHoleInUseBw indicates the bandwidth of
|
|
the ingress multicast traffic that is being black holed on the MDA."
|
|
::= { tmnxMDAEntry 39 }
|
|
|
|
--
|
|
-- Card Type Definition Table
|
|
--
|
|
tmnxCardTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCardTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The card type table has an entry for each Alcatel 7x50 SR series
|
|
card model."
|
|
::= { tmnxCardObjs 9 }
|
|
|
|
tmnxCardTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxCardTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7x50 SR series Card model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxCardTypeIndex }
|
|
::= { tmnxCardTypeTable 1 }
|
|
|
|
TmnxCardTypeEntry ::=
|
|
SEQUENCE {
|
|
tmnxCardTypeIndex TmnxCardType,
|
|
tmnxCardTypeName TNamedItemOrEmpty,
|
|
tmnxCardTypeDescription TItemDescription,
|
|
tmnxCardTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxCardTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxCardType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Alcatel
|
|
7x50 SR series card model."
|
|
::= { tmnxCardTypeEntry 1 }
|
|
|
|
tmnxCardTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Alcatel
|
|
7x50 SR series card model. This name string may be used in
|
|
CLI commands to specify a particular card model type."
|
|
::= { tmnxCardTypeEntry 2 }
|
|
|
|
tmnxCardTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Alcatel 7x50 SR series card model."
|
|
::= { tmnxCardTypeEntry 3 }
|
|
|
|
tmnxCardTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxCardTypeStatus has a value of 'true' it indicates that
|
|
this card model is supported in this revision of the management
|
|
software. When it has a value of 'false' there is no support."
|
|
::= { tmnxCardTypeEntry 4 }
|
|
|
|
|
|
--
|
|
-- MDA Type Defintion Table
|
|
--
|
|
tmnxMdaTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxMdaTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MDA type table has an entry for each Alcatel 7x50 SR series
|
|
MDA card model."
|
|
::= { tmnxCardObjs 10 }
|
|
|
|
tmnxMdaTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxMdaTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7x50 SR series MDA card model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxMdaTypeIndex }
|
|
::= { tmnxMdaTypeTable 1 }
|
|
|
|
TmnxMdaTypeEntry ::=
|
|
SEQUENCE {
|
|
tmnxMdaTypeIndex TmnxMdaType,
|
|
tmnxMdaTypeName TNamedItemOrEmpty,
|
|
tmnxMdaTypeDescription TItemDescription,
|
|
tmnxMdaTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxMdaTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxMdaType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Alcatel
|
|
7x50 SR series MDA card model."
|
|
::= { tmnxMdaTypeEntry 1 }
|
|
|
|
tmnxMdaTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Alcatel
|
|
7x50 SR series MDA card model. This name string may be used
|
|
in CLI commands to specify a particular MDA card model type."
|
|
::= { tmnxMdaTypeEntry 2 }
|
|
|
|
tmnxMdaTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Alcatel 7x50 SR series MDA card
|
|
model."
|
|
::= { tmnxMdaTypeEntry 3 }
|
|
|
|
tmnxMdaTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxMdaTypeStatus has a value of 'true' it indicates that
|
|
this MDA card model is supported in this revision of the management
|
|
software. When it has a value of 'false' there is no support."
|
|
::= { tmnxMdaTypeEntry 4 }
|
|
|
|
--
|
|
-- Synchronous interface timing information for the CPM card
|
|
--
|
|
|
|
tmnxSyncIfTimingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxSyncIfTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The synchronous interface timing table has an entry for each cpm
|
|
card in the system."
|
|
::= { tmnxCardObjs 11 }
|
|
|
|
tmnxSyncIfTimingEntry OBJECT-TYPE
|
|
SYNTAX TmnxSyncIfTimingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row represents the configuration of synchronous equipment timing
|
|
subsystem (SETS) of the system. Entries cannot be created and deleted
|
|
via SNMP SET operations. When a tmnxCpmCardEntry is created, a
|
|
tmnxSyncIfTimingEntry is created. Note that the first Alcatel
|
|
7x50 SR series product release does not support configuration of
|
|
synchronous equipment on the secondary CPM. All SNMP operations
|
|
with tmnxCpmCardSlotNum of the secondary CPM will be denied.
|
|
|
|
If the value of the reference source port is a valid Port ID then the
|
|
reference is a port. If the value of the source hardware is a valid
|
|
non-zero HWIndex then the source is the hardware specified by the
|
|
HWIndex."
|
|
AUGMENTS { tmnxCpmCardEntry }
|
|
::= { tmnxSyncIfTimingTable 1 }
|
|
|
|
TmnxSyncIfTimingEntry ::=
|
|
SEQUENCE {
|
|
tmnxSyncIfTimingRevert TruthValue,
|
|
tmnxSyncIfTimingRefOrder1 TmnxSETSRefSource,
|
|
tmnxSyncIfTimingRefOrder2 TmnxSETSRefSource,
|
|
tmnxSyncIfTimingRef1SrcPort TmnxPortID,
|
|
tmnxSyncIfTimingRef1AdminStatus TmnxPortAdminStatus,
|
|
tmnxSyncIfTimingRef1InUse TruthValue,
|
|
tmnxSyncIfTimingRef1Qualified TmnxSETSRefQualified,
|
|
tmnxSyncIfTimingRef1Alarm TmnxSETSRefAlarm,
|
|
tmnxSyncIfTimingRef2SrcPort TmnxPortID,
|
|
tmnxSyncIfTimingRef2AdminStatus TmnxPortAdminStatus,
|
|
tmnxSyncIfTimingRef2InUse TruthValue,
|
|
tmnxSyncIfTimingRef2Qualified TmnxSETSRefQualified,
|
|
tmnxSyncIfTimingRef2Alarm TmnxSETSRefAlarm,
|
|
tmnxSyncIfTimingFreqOffset Integer32,
|
|
tmnxSyncIfTimingStatus INTEGER,
|
|
tmnxSyncIfTimingRefOrder3 TmnxSETSRefSource,
|
|
tmnxSyncIfTimingBITSIfType TmnxBITSIfType,
|
|
tmnxSyncIfTimingBITSAdminStatus TmnxPortAdminStatus,
|
|
tmnxSyncIfTimingBITSInUse TruthValue,
|
|
tmnxSyncIfTimingBITSQualified TmnxSETSRefQualified,
|
|
tmnxSyncIfTimingBITSAlarm TmnxSETSRefAlarm,
|
|
tmnxSyncIfTimingRef1SrcHw TmnxHwIndexOrZero,
|
|
tmnxSyncIfTimingRef1BITSIfType TmnxBITSIfType,
|
|
tmnxSyncIfTimingRef2SrcHw TmnxHwIndexOrZero,
|
|
tmnxSyncIfTimingRef2BITSIfType TmnxBITSIfType
|
|
}
|
|
|
|
tmnxSyncIfTimingRevert OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRevert indicates whether the reference
|
|
source will revert to a higher priority source that has been
|
|
re-validated or newly validated.
|
|
|
|
The synchronous interface timing subsystem is by default non-revertive
|
|
('false')."
|
|
::= { tmnxSyncIfTimingEntry 1 }
|
|
|
|
tmnxSyncIfTimingRefOrder1 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRefOrder1 indicates the most preferred
|
|
timing reference source.
|
|
|
|
The synchronous equipment timing subsystem can lock to three
|
|
different timing reference inputs, reference1, reference2 and bits.
|
|
The subsystem chooses a reference based on priority."
|
|
::= { tmnxSyncIfTimingEntry 2 }
|
|
|
|
tmnxSyncIfTimingRefOrder2 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRefOrder2 indicates the second most
|
|
preferred timing reference for the synchronous equipment timing
|
|
subsystem."
|
|
::= { tmnxSyncIfTimingEntry 3 }
|
|
|
|
tmnxSyncIfTimingRef1SrcPort OBJECT-TYPE
|
|
SYNTAX TmnxPortID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1SrcPort indicates the source port of
|
|
the first timing reference.
|
|
|
|
A value of '1e000000'H indicates that there is no source port for this
|
|
reference."
|
|
::= { tmnxSyncIfTimingEntry 4 }
|
|
|
|
tmnxSyncIfTimingRef1AdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1AdminStatus indicates the
|
|
administrative status of the first timing reference."
|
|
::= { tmnxSyncIfTimingEntry 5 }
|
|
|
|
tmnxSyncIfTimingRef1InUse OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1InUse indicates whether the first
|
|
timing reference is presently being used by the synchronous timing
|
|
subsystem. If it is in use, tmnxSyncIfTimingFreqOffset indicates
|
|
the frequency offset for this reference."
|
|
::= { tmnxSyncIfTimingEntry 6 }
|
|
|
|
tmnxSyncIfTimingRef1Qualified OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefQualified
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1Qualified indicates whether the first
|
|
timing reference is qualified for use by the synchronous timing
|
|
subsystem. If tmnxSyncIfTimingRef1Qualified is set to 'not-qualified',
|
|
then the object tmnxSyncIfTimingRef1Alarm gives the reason for
|
|
disqualification."
|
|
::= { tmnxSyncIfTimingEntry 7 }
|
|
|
|
tmnxSyncIfTimingRef1Alarm OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefAlarm
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1Alarm indicates the alarms on the
|
|
first reference. If any of the bits is set to '1', then the first
|
|
reference is disqualified by the timing subsystem and the value of
|
|
tmnxSyncIfTimingRef1Qualified is set to 'not-qualified'.
|
|
los - loss of signal
|
|
oof - out of frequency range
|
|
oopir - out of pull in range
|
|
"
|
|
::= { tmnxSyncIfTimingEntry 8 }
|
|
|
|
tmnxSyncIfTimingRef2SrcPort OBJECT-TYPE
|
|
SYNTAX TmnxPortID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2SrcPort indicates the source port of
|
|
the second timing reference.
|
|
|
|
A value of '1e000000'H indicates that there is no source port for this
|
|
reference."
|
|
::= { tmnxSyncIfTimingEntry 9 }
|
|
|
|
tmnxSyncIfTimingRef2AdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2AdminStatus indicates the
|
|
administrative status of the second timing reference."
|
|
::= { tmnxSyncIfTimingEntry 10 }
|
|
|
|
tmnxSyncIfTimingRef2InUse OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2InUse indicates whether the second
|
|
timing reference is presently being used by the synchronous timing
|
|
subsystem."
|
|
::= { tmnxSyncIfTimingEntry 11 }
|
|
|
|
tmnxSyncIfTimingRef2Qualified OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefQualified
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2Qualified indicates whether the
|
|
second timing reference is qualified for use by the synchronous
|
|
timing subsystem. If tmnxSyncIfTimingRef2Qualified is 'not-qualified'
|
|
then the object tmnxSyncIfTimingRef2Alarm gives the reason for
|
|
disqualification."
|
|
::= { tmnxSyncIfTimingEntry 12 }
|
|
|
|
tmnxSyncIfTimingRef2Alarm OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefAlarm
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2Alarm indicates the alarms on the
|
|
second reference. If any of the bits is set to '1', then the second
|
|
reference is disqualified by the timing subsystem and the value of
|
|
tmnxSyncIfTimingRef2Qualified is set to 'not-qualified'.
|
|
los - loss of signal
|
|
oof - out of frequency range
|
|
oopir - out of pull in range
|
|
"
|
|
::= { tmnxSyncIfTimingEntry 13 }
|
|
|
|
tmnxSyncIfTimingFreqOffset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "parts-per-million"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingFreqOffset indicates the frequency offset
|
|
of the current selected timing reference in parts per million (ppm)."
|
|
::= { tmnxSyncIfTimingEntry 14 }
|
|
|
|
tmnxSyncIfTimingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
not-present (1),
|
|
master-freerun (2),
|
|
master-holdover (3),
|
|
master-locked (4),
|
|
slave (5),
|
|
acquiring (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingStatus indicates the present status of
|
|
the synchronous timing equipment subsystem (SETS)."
|
|
::= { tmnxSyncIfTimingEntry 15 }
|
|
|
|
tmnxSyncIfTimingRefOrder3 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRefOrder3 is the third most preferred
|
|
timing reference for the synchronous equipment timing subsystem."
|
|
::= { tmnxSyncIfTimingEntry 16 }
|
|
|
|
tmnxSyncIfTimingBITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingBITSIfType indicates the interface type
|
|
of the BITS (Building Integrated Timing Supply) timing reference. It
|
|
also indicates the framing type of the interface."
|
|
::= { tmnxSyncIfTimingEntry 17 }
|
|
|
|
tmnxSyncIfTimingBITSAdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingBITSAdminStatus indicates administrative
|
|
status of the BITS (Building Integrated Timing Supply) timing
|
|
reference."
|
|
::= { tmnxSyncIfTimingEntry 18 }
|
|
|
|
tmnxSyncIfTimingBITSInUse OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingBITSInUse indicates whether the BITS
|
|
timing reference is presently being used by the synchronous timing
|
|
subsystem. If it is in use, tmnxSyncIfTimingFreqOffset indicates
|
|
the frequency offset for this reference."
|
|
::= { tmnxSyncIfTimingEntry 19 }
|
|
|
|
tmnxSyncIfTimingBITSQualified OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefQualified
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingBITSQualified indicates whether the BITS
|
|
timing reference is qualified for use by the synchronous timing
|
|
subsystem. If tmnxSyncIfTimingBITSQualified is 'not-qualified', then
|
|
the object tmnxSyncIfTimingBITSAlarm gives the reason for
|
|
disqualification."
|
|
::= { tmnxSyncIfTimingEntry 20 }
|
|
|
|
tmnxSyncIfTimingBITSAlarm OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefAlarm
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingBITSAlarm indicates the alarms on the
|
|
BITS reference. If any of the bits is set to '1', then the BITS
|
|
reference is disqualified by the timing subsystem and the value of
|
|
tmnxSyncIfTimingBITSQualified is set to 'not-qualified'."
|
|
::= { tmnxSyncIfTimingEntry 21 }
|
|
|
|
tmnxSyncIfTimingRef1SrcHw OBJECT-TYPE
|
|
SYNTAX TmnxHwIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1SrcHw indicates the source HW
|
|
index of the first timing reference if source is not a port."
|
|
::= { tmnxSyncIfTimingEntry 22 }
|
|
|
|
tmnxSyncIfTimingRef1BITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef1BITSIfType indicates the interface
|
|
type of the first timing reference if the source is BITS. It also
|
|
indicates the framing type of the interface."
|
|
::= { tmnxSyncIfTimingEntry 23 }
|
|
|
|
tmnxSyncIfTimingRef2SrcHw OBJECT-TYPE
|
|
SYNTAX TmnxHwIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2SrcHw indicates the source HW
|
|
index of the second timing reference if source is not a port."
|
|
::= { tmnxSyncIfTimingEntry 24 }
|
|
|
|
tmnxSyncIfTimingRef2BITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxSyncIfTimingRef2BITSIfType indicates the interface
|
|
type of the second timing reference if the source is BITS. It also
|
|
indicates the framing type of the interface."
|
|
::= { tmnxSyncIfTimingEntry 25 }
|
|
|
|
|
|
--
|
|
-- Administrative value objects
|
|
--
|
|
tmnxChassisAdminCtrlObjs OBJECT IDENTIFIER ::= { tmnxChassisAdminObjects 1 }
|
|
tmnxChassisAdminValueObjs OBJECT IDENTIFIER ::= { tmnxChassisAdminObjects 2 }
|
|
|
|
--
|
|
-- Admin Synchoronous Interface Timing table
|
|
--
|
|
|
|
tSyncIfTimingAdmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TSyncIfTimingAdmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Values for the synchronous interface timing for the chassis."
|
|
::= { tmnxChassisAdminValueObjs 1 }
|
|
|
|
tSyncIfTimingAdmEntry OBJECT-TYPE
|
|
SYNTAX TSyncIfTimingAdmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about the synchronous interface timing.
|
|
Entries are created by user.
|
|
Entries are deleted by user.
|
|
Note that the first Alcatel 7x50 SR series product release does
|
|
not support configuration of synchronous timing equipment on the
|
|
secondary CPM. All SNMP operations with tmnxCpmCardSlotNum of the
|
|
secondary CPM will be denied.
|
|
|
|
The 7x50 systems supports 3 timing references (reference1, reference2
|
|
and bits).
|
|
|
|
The 7710 system only supports 2 timing references (reference1 and
|
|
reference2). On 7710 system, references can be a source port
|
|
or a BITS input on a CES CMA. If the value of the reference source
|
|
port is a valid Port ID then the reference is a source port. If the
|
|
value of the source hardware is a valid HWIndex of a CES CMA then the
|
|
source is a BITS on the CES CMA."
|
|
INDEX { tmnxChassisIndex, tmnxCpmCardSlotNum, tmnxCpmCardNum }
|
|
::= { tSyncIfTimingAdmTable 1 }
|
|
|
|
TSyncIfTimingAdmEntry ::=
|
|
SEQUENCE {
|
|
tSyncIfTimingAdmRevert TruthValue,
|
|
tSyncIfTimingAdmRefOrder1 TmnxSETSRefSource,
|
|
tSyncIfTimingAdmRefOrder2 TmnxSETSRefSource,
|
|
tSyncIfTimingAdmRef1SrcPort TmnxPortID,
|
|
tSyncIfTimingAdmRef1AdminStatus TmnxPortAdminStatus,
|
|
tSyncIfTimingAdmRef2SrcPort TmnxPortID,
|
|
tSyncIfTimingAdmRef2AdminStatus TmnxPortAdminStatus,
|
|
tSyncIfTimingAdmChanged Unsigned32,
|
|
tSyncIfTimingAdmRefOrder3 TmnxSETSRefSource,
|
|
tSyncIfTimingAdmBITSIfType TmnxBITSIfType,
|
|
tSyncIfTimingAdmBITSAdminStatus TmnxPortAdminStatus,
|
|
tSyncIfTimingAdmRef1SrcHw TmnxHwIndexOrZero,
|
|
tSyncIfTimingAdmRef1BITSIfType TmnxBITSIfType,
|
|
tSyncIfTimingAdmRef2SrcHw TmnxHwIndexOrZero,
|
|
tSyncIfTimingAdmRef2BITSIfType TmnxBITSIfType
|
|
}
|
|
|
|
tSyncIfTimingAdmRevert OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRevert specifies whether the reference
|
|
source will revert to a higher priority source that has been
|
|
re-validated or newly validated.
|
|
|
|
The synchronous interface timing subsystem is by default non-revertive
|
|
('false')."
|
|
DEFVAL { false }
|
|
::= { tSyncIfTimingAdmEntry 1 }
|
|
|
|
tSyncIfTimingAdmRefOrder1 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRefOrder1 specifies the most preferred
|
|
timing reference source.
|
|
|
|
The synchronous equipment timing subsystem can lock to three
|
|
different timing reference inputs, reference1, reference2 and bits.
|
|
The subsystem chooses a reference based on priority.
|
|
tSyncIfTimingAdmRefOrder1 is used to configure the most preferred
|
|
timing reference."
|
|
DEFVAL { bits }
|
|
::= { tSyncIfTimingAdmEntry 2 }
|
|
|
|
tSyncIfTimingAdmRefOrder2 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRefOrder2 specifies the second most
|
|
preferred timing reference for the synchronous equipment timing
|
|
subsystem."
|
|
DEFVAL { reference1 }
|
|
::= { tSyncIfTimingAdmEntry 3 }
|
|
|
|
tSyncIfTimingAdmRef1SrcPort OBJECT-TYPE
|
|
SYNTAX TmnxPortID
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef1SrcPort specifies the source port
|
|
of the first timing reference.
|
|
|
|
This can only be set to a valid TmnxPortID if the value of
|
|
tSyncIfTimingAdmRef1SrcHw is 0."
|
|
DEFVAL { '1e000000'H }
|
|
::= { tSyncIfTimingAdmEntry 4 }
|
|
|
|
tSyncIfTimingAdmRef1AdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef1AdminStatus specifies the desired
|
|
administrative status of the first timing reference."
|
|
DEFVAL { outOfService }
|
|
::= { tSyncIfTimingAdmEntry 5 }
|
|
|
|
tSyncIfTimingAdmRef2SrcPort OBJECT-TYPE
|
|
SYNTAX TmnxPortID
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef2SrcPort specifies the source port
|
|
of the second timing reference.
|
|
|
|
This can only be set to a valid TmnxPortID if the value of
|
|
tSyncIfTimingAdmRef2SrcHw is 0."
|
|
DEFVAL { '1e000000'H }
|
|
::= { tSyncIfTimingAdmEntry 6 }
|
|
|
|
tSyncIfTimingAdmRef2AdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef2AdminStatus specifies the desired
|
|
administrative status of the second timing reference."
|
|
DEFVAL { outOfService }
|
|
::= { tSyncIfTimingAdmEntry 7 }
|
|
|
|
tSyncIfTimingAdmChanged OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmChanged is a bitmask that indicates which
|
|
objects have been set, but not committed. bit values used here are:
|
|
|
|
0x0001: tSyncIfTimingAdmRevert
|
|
0x0002: tSyncIfTimingAdmRefOrder1
|
|
0x0004: tSyncIfTimingAdmRefOrder2
|
|
0x0008: tSyncIfTimingAdmRef1SrcPort
|
|
0x0010: tSyncIfTimingAdmRef1AdminStatus
|
|
0x0020: tSyncIfTimingAdmRef2SrcPort
|
|
0x0040: tSyncIfTimingAdmRef2AdminStatus
|
|
0x0080: tSyncIfTimingAdmRefOrder3
|
|
0x0100: tSyncIfTimingAdmBITSIfType
|
|
0x0200: tSyncIfTimingAdmBITSAdminStatus
|
|
0x0400: tSyncIfTimingAdmRef1SrcHw
|
|
0x0800: tSyncIfTimingAdmRef1BITSIfType
|
|
0x1000: tSyncIfTimingAdmRef2SrcHw
|
|
0x2000: tSyncIfTimingAdmRef2BITSIfType
|
|
|
|
The agent sets these bits when an object in the row
|
|
is set. This object is cleared to zero by setting
|
|
tmnxChassisAdminControlApply to initialize(2) or commit(3).
|
|
"
|
|
::= { tSyncIfTimingAdmEntry 8 }
|
|
|
|
tSyncIfTimingAdmRefOrder3 OBJECT-TYPE
|
|
SYNTAX TmnxSETSRefSource
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRefOrder3 indicates the third most
|
|
preferred timing reference for the synchronous equipment timing
|
|
subsystem."
|
|
DEFVAL { reference2 }
|
|
::= { tSyncIfTimingAdmEntry 9 }
|
|
|
|
tSyncIfTimingAdmBITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmBITSIfType specifies the interface type
|
|
of the BITS (Building Integrated Timing Supply) timing reference."
|
|
DEFVAL { t1-esf }
|
|
::= { tSyncIfTimingAdmEntry 10 }
|
|
|
|
tSyncIfTimingAdmBITSAdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortAdminStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmBITSAdminStatus specifies the desired
|
|
administrative status of the BITS (Building Integrated Timing Supply)
|
|
timing reference."
|
|
DEFVAL { outOfService }
|
|
::= { tSyncIfTimingAdmEntry 11 }
|
|
|
|
tSyncIfTimingAdmRef1SrcHw OBJECT-TYPE
|
|
SYNTAX TmnxHwIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef1SrcHw specifies the source HW
|
|
Index of the first timing reference if the source is not a port.
|
|
|
|
This can only be set to a valid HW Index if the value of
|
|
tSyncIfTimingAdmRef1SrcPort is '1e000000'H."
|
|
DEFVAL { 0 }
|
|
::= { tSyncIfTimingAdmEntry 12 }
|
|
|
|
tSyncIfTimingAdmRef1BITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef1BITSIfType specifies the interface
|
|
type of the first timing reference if the source is BITS."
|
|
DEFVAL { t1-esf }
|
|
::= { tSyncIfTimingAdmEntry 13 }
|
|
|
|
tSyncIfTimingAdmRef2SrcHw OBJECT-TYPE
|
|
SYNTAX TmnxHwIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef2SrcHw specifies the source HW
|
|
Index of the second timing reference if the source is not a port.
|
|
|
|
This can only be set to a valid HW Index if the value of
|
|
tSyncIfTimingAdmRef2SrcPort is '1e000000'H."
|
|
DEFVAL { 0 }
|
|
::= { tSyncIfTimingAdmEntry 14 }
|
|
|
|
tSyncIfTimingAdmRef2BITSIfType OBJECT-TYPE
|
|
SYNTAX TmnxBITSIfType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tSyncIfTimingAdmRef2BITSIfType specifies the interface
|
|
type of the second timing reference if the source is BITS."
|
|
DEFVAL { t1-esf }
|
|
::= { tSyncIfTimingAdmEntry 15 }
|
|
|
|
|
|
--
|
|
-- Administrative value control objects
|
|
--
|
|
|
|
tmnxChassisAdminOwner OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Who has last initialized the chassis administrative table,
|
|
who is making all the changes, and who is expected to
|
|
either commit or re-initialize (ABORT-TRANSACTION).
|
|
|
|
tmnxChassisAdminOwner is advisory only. Before beginning a transaction,
|
|
read tmnxChassisAdminOwner. if it is empty then proceed with the
|
|
configuration.
|
|
|
|
Set tmnxChassisAdminOwner after setting tmnxChassisAdminControlApply so
|
|
that other users will be advised to not make changes to the Admin
|
|
tables.
|
|
|
|
Agent sets tmnxChassisAdminOwner to empty string after
|
|
tmnxChassisAdminControlApply is set - either by user initializing or
|
|
committing, or by agent timing out the uncommitted transactions
|
|
(tmnxChassisAdminLastSetTimer).
|
|
"
|
|
::= { tmnxChassisAdminCtrlObjs 1 }
|
|
|
|
tmnxChassisAdminControlApply OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
initialize(2),
|
|
commit(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the use of tmnxChassisAdminTable.
|
|
|
|
when set to initialize(2), the objects in tmnxChassisAdminTable
|
|
are set to the current Operational values, from the tmnxChassisTable.
|
|
Any uncommitted changes are lost, so setting this value corresponds
|
|
to both BEGIN-TRANSACTION and ABORT-TRANSACTION.
|
|
|
|
when set to commit(3) (END-TRANSACTION), all of the objects from
|
|
tmnxChassisAdminTable are copied to the corresponding tmnxChassisTable
|
|
table objects.
|
|
"
|
|
::= { tmnxChassisAdminCtrlObjs 2 }
|
|
|
|
tmnxChassisAdminLastSetTimer OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centiseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time remaining until the agent re-initializes the
|
|
administrative tables.
|
|
|
|
If tmnxChassisAdminControlApply is not set to commit(3) within
|
|
tmnxChassisAdminLastSetTimeout centiseconds, the agent will set it
|
|
to initialize(2) and all uncommitted changes will be lost.
|
|
|
|
This way, uncommitted changes from failed (uncompleted) change sets
|
|
will eventually be removed, and another transaction can safely begin.
|
|
|
|
this object is reset to tmnxChassisAdminLastSetTimeout after SNMP SET
|
|
operation to any of the tmnxChassisAdminValue tables.
|
|
"
|
|
::= { tmnxChassisAdminCtrlObjs 3 }
|
|
|
|
tmnxChassisAdminLastSetTimeout OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centiseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout for tmnxChassisAdminLastSetTimer.
|
|
The value zero is not allowed.
|
|
"
|
|
DEFVAL { 180000 }
|
|
::= { tmnxChassisAdminCtrlObjs 4 }
|
|
|
|
|
|
--
|
|
-- Cross Connect Aggregation Group Table
|
|
--
|
|
|
|
tmnxCcagTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCcagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxCcagTable has an entry for each Cross Connect Aggregation
|
|
Group,CCAG, configured on this system."
|
|
::= { tmnxCardObjs 12 }
|
|
|
|
tmnxCcagEntry OBJECT-TYPE
|
|
SYNTAX TmnxCcagEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a particular CCAG.
|
|
Entries are created/deleted by the user.
|
|
There is no StorageType object, entries have a presumed
|
|
StorageType of nonVolatile."
|
|
INDEX { tmnxCcagId }
|
|
::= { tmnxCcagTable 1}
|
|
|
|
TmnxCcagEntry ::= SEQUENCE
|
|
{
|
|
tmnxCcagId TmnxCcagId,
|
|
tmnxCcagRowStatus RowStatus,
|
|
tmnxCcagLastChanged TimeStamp,
|
|
tmnxCcagDescription DisplayString,
|
|
tmnxCcagAdminStatus TmnxAdminState,
|
|
tmnxCcagOperStatus TmnxOperState,
|
|
tmnxCcagCcaRate TmnxCcagRate,
|
|
tmnxCcagAccessAdaptQos INTEGER
|
|
}
|
|
|
|
tmnxCcagId OBJECT-TYPE
|
|
SYNTAX TmnxCcagId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagId is used to index into the
|
|
tmnxCcagTable. It uniquely identifies a CCAG entry
|
|
as configured on this system."
|
|
::= { tmnxCcagEntry 1 }
|
|
|
|
tmnxCcagRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagRowStatus specifies the row status. It
|
|
allows entries to be created and deleted in the tmnxCcagTable.
|
|
tmnxCcagRowStatus does not support createAndWait. The status
|
|
can only be active or notInService."
|
|
::= { tmnxCcagEntry 2 }
|
|
|
|
tmnxCcagLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagLastChanged indicates the time this row
|
|
was last changed."
|
|
::= { tmnxCcagEntry 3 }
|
|
|
|
tmnxCcagDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagDescription specifies a user provided
|
|
description string of this CCAG entry."
|
|
DEFVAL { ''H }
|
|
::= { tmnxCcagEntry 4 }
|
|
|
|
tmnxCcagAdminStatus OBJECT-TYPE
|
|
SYNTAX TmnxAdminState
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagAdminStatus specifies the desired state of this
|
|
CCAG."
|
|
DEFVAL { inService }
|
|
::= { tmnxCcagEntry 5 }
|
|
|
|
tmnxCcagOperStatus OBJECT-TYPE
|
|
SYNTAX TmnxOperState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagOperStatus indicates the operational state of this
|
|
CCAG."
|
|
::= { tmnxCcagEntry 6 }
|
|
|
|
tmnxCcagCcaRate OBJECT-TYPE
|
|
SYNTAX TmnxCcagRate
|
|
UNITS "kilobits per second"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagCcaRate specifies the maximum forwarding rate
|
|
for each CCA member within the CCAG."
|
|
DEFVAL { -1 }
|
|
::= { tmnxCcagEntry 7 }
|
|
|
|
tmnxCcagAccessAdaptQos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
link (1),
|
|
distribute (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagAccessAdaptQos specifies how the CCAG SAP queue
|
|
and virtual scheduler buffering and rate parameters are adapted over
|
|
multiple active CCAs.
|
|
link (1) - The CCAG will create the SAP queues and virtual
|
|
schedulers on each CCA with the actual parameters
|
|
specified in the tmnxCcagPathCcTable.
|
|
distribute (2) - Each CCA will receive a portion of the parameters
|
|
specified in the tmnxCcagPathCcTable."
|
|
DEFVAL { distribute }
|
|
::= { tmnxCcagEntry 8 }
|
|
|
|
--
|
|
-- Cross Connect Aggregation Group Path Table
|
|
--
|
|
|
|
tmnxCcagPathTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCcagPathEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxCcagPathTable has an entry for each Cross Connect
|
|
Aggregation Group, CCAG, path configured on this system."
|
|
::= { tmnxCardObjs 13 }
|
|
|
|
tmnxCcagPathEntry OBJECT-TYPE
|
|
SYNTAX TmnxCcagPathEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a particular CCAG Path.
|
|
Entries are created/deleted by the user.
|
|
There is no StorageType object, entries have a presumed
|
|
StorageType of nonVolatile."
|
|
INDEX { tmnxCcagId, tmnxCcagPathId }
|
|
::= { tmnxCcagPathTable 1}
|
|
|
|
TmnxCcagPathEntry ::= SEQUENCE
|
|
{
|
|
tmnxCcagPathId INTEGER,
|
|
tmnxCcagPathLastChanged TimeStamp,
|
|
tmnxCcagPathRate TmnxCcagRate,
|
|
tmnxCcagPathRateOption TmnxCcagRateOption,
|
|
tmnxCcagPathWeight Unsigned32
|
|
}
|
|
|
|
tmnxCcagPathId OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
alpha (1),
|
|
beta (2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathId is used as the secondary index into
|
|
the tmnxCcagPathTable. Along with tmnxCcagId, it uniquely identifies
|
|
a specific path, alpha or beta, on a CCAG."
|
|
::= { tmnxCcagPathEntry 1 }
|
|
|
|
tmnxCcagPathLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathLastChanged indicates the time this row
|
|
was last changed."
|
|
::= { tmnxCcagPathEntry 2 }
|
|
|
|
tmnxCcagPathRate OBJECT-TYPE
|
|
SYNTAX TmnxCcagRate
|
|
UNITS "kilobits per second"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathRate specifies the bandwidth rate
|
|
limitation for this path on each member cross connect
|
|
adaptor, CCA, in the CCAG."
|
|
DEFVAL { -1 }
|
|
::= { tmnxCcagPathEntry 3 }
|
|
|
|
tmnxCcagPathRateOption OBJECT-TYPE
|
|
SYNTAX TmnxCcagRateOption
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathRateOption specifies whether the
|
|
rate in tmnxCcagPathRate is defined as an aggregate path
|
|
rate for all CCAs in the CCAG or as a per CCA path
|
|
rate."
|
|
DEFVAL { aggregate }
|
|
::= { tmnxCcagPathEntry 4 }
|
|
|
|
tmnxCcagPathWeight OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..100)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathWeight specifies the scheduling
|
|
percentage for this path. It is applied to all CCAs in
|
|
the CCAG membership list for this path."
|
|
DEFVAL { 50 }
|
|
::= { tmnxCcagPathEntry 5 }
|
|
|
|
--
|
|
-- CCAG Path Cross-Connect Table
|
|
--
|
|
|
|
tmnxCcagPathCcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxCcagPathCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxCcagPathCcTable has an entry for each type of Cross
|
|
Connection on a Cross Connect Aggregation Group Path
|
|
configured on this system."
|
|
::= { tmnxCardObjs 14 }
|
|
|
|
tmnxCcagPathCcEntry OBJECT-TYPE
|
|
SYNTAX TmnxCcagPathCcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a particular CCAG Path Cross Connect.
|
|
Entries are created/deleted by the user.
|
|
There is no StorageType object, entries have a presumed
|
|
StorageType of nonVolatile."
|
|
INDEX { tmnxCcagId, tmnxCcagPathId, tmnxCcagPathCcType }
|
|
::= { tmnxCcagPathCcTable 1}
|
|
|
|
TmnxCcagPathCcEntry ::= SEQUENCE
|
|
{
|
|
tmnxCcagPathCcType INTEGER,
|
|
tmnxCcagPathCcLastChanged TimeStamp,
|
|
tmnxCcagPathCcEgrPoolResvCbs INTEGER,
|
|
tmnxCcagPathCcEgrPoolSlpPlcy TNamedItem,
|
|
tmnxCcagPathCcIngPoolResvCbs INTEGER,
|
|
tmnxCcagPathCcIngPoolSlpPlcy TNamedItem,
|
|
tmnxCcagPathCcAcctPolicyId Unsigned32,
|
|
tmnxCcagPathCcCollectStats TruthValue,
|
|
tmnxCcagPathCcQueuePlcy TNamedItem,
|
|
tmnxCcagPathCcMac MacAddress,
|
|
tmnxCcagPathCcMtu Unsigned32,
|
|
tmnxCcagPathCcUserAssignedMac TruthValue,
|
|
tmnxCcagPathCcHwMac MacAddress
|
|
}
|
|
|
|
tmnxCcagPathCcType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sapsap (1),
|
|
sapnet (2),
|
|
netsap (3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcType is used as a third index into
|
|
the tmnxCcagPathCcTable. Along with tmnxCcagId and tmnxCcagPathId,
|
|
it uniquely identifies a cross connection type on a specific path
|
|
in a particular CCAG. The types are:
|
|
sapsap (1): the cross connection is between two saps, where both
|
|
services are access.
|
|
sapnet (2): the cross connection is between a sap and a network
|
|
service.
|
|
netsap (3): the cross connection is between a network and a sap
|
|
service."
|
|
::= { tmnxCcagPathCcEntry 1 }
|
|
|
|
tmnxCcagPathCcLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcLastChanged indicates the time this row
|
|
was last changed."
|
|
::= { tmnxCcagPathCcEntry 2 }
|
|
|
|
tmnxCcagPathCcEgrPoolResvCbs OBJECT-TYPE
|
|
SYNTAX INTEGER (-1|0..100)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcEgrPoolResvCbs specifies the percentage
|
|
of pool size reserved for the committed burst size, CBS. The value '-1'
|
|
implies that the reserved CBS should be computed as the sum of
|
|
the CBS requested by the entities using this pool if the application
|
|
point is 'network'. For 'access' application points the value '-1'
|
|
means a default of 30%."
|
|
DEFVAL { -1 }
|
|
::= { tmnxCcagPathCcEntry 3 }
|
|
|
|
tmnxCcagPathCcEgrPoolSlpPlcy OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcEgrPoolSlpPlcy specifies the slope
|
|
policy being used for the egress pool. The Slope policies define the
|
|
nature of the RED Slopes for the high and the low priority traffic."
|
|
DEFVAL { "default" }
|
|
::= { tmnxCcagPathCcEntry 4 }
|
|
|
|
tmnxCcagPathCcIngPoolResvCbs OBJECT-TYPE
|
|
SYNTAX INTEGER (-1|0..100)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcIngPoolResvCbs specifies the percentage
|
|
of pool size reserved for the committed burst size, CBS. The value '-1'
|
|
implies that the reserved CBS should be computed as the sum of
|
|
the CBS requested by the entities using this pool if the application
|
|
point is 'network'. For 'access' application points the value '-1'
|
|
means a default of 30%. tmnxCcagPathCcIngPoolResvCbs does not apply
|
|
to tmnxCcagPathCcType 'netsap'."
|
|
DEFVAL { -1 }
|
|
::= { tmnxCcagPathCcEntry 5 }
|
|
|
|
tmnxCcagPathCcIngPoolSlpPlcy OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcIngPoolSlpPlcy specifies the slope policy
|
|
being used for the ingress pool. The Slope policies define the nature
|
|
of the RED Slopes for the high and the low priority traffic.
|
|
tmnxCcagPathCcIngPoolSlpPlcy does not apply to tmnxCcagPathCcType
|
|
'netsap'."
|
|
DEFVAL { "default" }
|
|
::= { tmnxCcagPathCcEntry 6 }
|
|
|
|
tmnxCcagPathCcAcctPolicyId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..99)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcAcctPolicyId specifies the accounting
|
|
policy which must be defined prior to associating it with the port.
|
|
A non-zero value indicates the tmnxLogApPolicyId index identifying the
|
|
policy entry in the tmnxLogApTable from the TIMETRA-LOG-MIB which is
|
|
associated with this port. A zero value indicates that there is no
|
|
accounting policy associated with this port. It is only meaningful
|
|
when the tmnxCcagPathCcType is 'netsap'."
|
|
DEFVAL { 0 }
|
|
::= { tmnxCcagPathCcEntry 7 }
|
|
|
|
tmnxCcagPathCcCollectStats OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcCollectStats specifies whether the collection
|
|
of accounting and statistical data for the network port is
|
|
enabled/disabled, 'true'/'false'. When applying accounting policies the
|
|
data by default will be collected in the appropriate records and
|
|
written to the designated billing file.
|
|
When the value is set to false, the statistics are still accumulated
|
|
by the IOM cards, however, the CPU will not obtain the results and
|
|
write them to the billing file. If the value of tmnxCcagPathCcType is
|
|
not 'netsap', the value of this object is meaningless and an attempt
|
|
to set it will result in an inconsistentValue error."
|
|
DEFVAL { false }
|
|
::= { tmnxCcagPathCcEntry 8 }
|
|
|
|
tmnxCcagPathCcQueuePlcy OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcQueuePlcy specifies the network egress
|
|
queue policy. If the value of tmnxCcagPathCcType is
|
|
not 'netsap', the value of this object is meaningless and an attempt
|
|
to set it will result in an inconsistentValue error."
|
|
DEFVAL { "default" }
|
|
::= { tmnxCcagPathCcEntry 9 }
|
|
|
|
tmnxCcagPathCcMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcMac specifies the MAC address of
|
|
the virtual LAG that maps to tmnxCcagPathId and tmnxCcagPathCcType.
|
|
The default value of this object is derived from the chassis MAC
|
|
address pool."
|
|
DEFVAL {'000000000000'h }
|
|
::= { tmnxCcagPathCcEntry 10 }
|
|
|
|
tmnxCcagPathCcMtu OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcMtu specifies the MTU of the path
|
|
indexed by tmnxCcagId, tmnxCcagPathId, and tmnxCcagPathCcType.
|
|
When the value is '0', the real MTU is calculated internally."
|
|
DEFVAL { 0 }
|
|
::= { tmnxCcagPathCcEntry 11 }
|
|
|
|
tmnxCcagPathCcUserAssignedMac OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcUserAssignedMac indicates whether
|
|
the value of tmnxCcagPathCcMac has been explicitly assigned
|
|
or inherited from tmnxCcagPathCcHwMac, 'true' and 'false',
|
|
respectively."
|
|
DEFVAL { false }
|
|
::= { tmnxCcagPathCcEntry 12 }
|
|
|
|
tmnxCcagPathCcHwMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxCcagPathCcHwMac is the system assigned MAC
|
|
address of the virtual LAG that maps to tmnxCcagPathId and
|
|
tmnxCcagPathCcType. When tmnxCcagPathCcUserAssignedMac is
|
|
'false', tmnxCcagPathCcMac inherits its value from this object."
|
|
::= { tmnxCcagPathCcEntry 13 }
|
|
|
|
|
|
--
|
|
-- Alcatel 7710 SR series Mda Carrier Module (MCM) Table
|
|
--
|
|
|
|
tmnxMcmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxMcmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxMcmTable has an entry for each Mda Carrier module
|
|
(MCM) on the 7710 system."
|
|
::= { tmnxCardObjs 15 }
|
|
|
|
tmnxMcmEntry OBJECT-TYPE
|
|
SYNTAX TmnxMcmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents a MCM in a chassis in the 7710 system.
|
|
Entries in the table cannot be created and deleted via SNMP SET
|
|
operations. When a tmnxChassisEntry is created, a
|
|
tmnxMcmEntry is created in the chassis. Before a
|
|
tmnxChassisEntry can be deleted, each tmnxMcmEntry
|
|
for the chassis must be in the proper state for removal."
|
|
INDEX { tmnxChassisIndex, tmnxCardSlotNum, tmnxMcmSlotNum }
|
|
::= { tmnxMcmTable 1 }
|
|
|
|
TmnxMcmEntry ::=
|
|
SEQUENCE {
|
|
tmnxMcmSlotNum Unsigned32,
|
|
tmnxMcmSupportedTypes TmnxMcmType,
|
|
tmnxMcmAssignedType TmnxMcmType,
|
|
tmnxMcmEquippedType TmnxMcmType,
|
|
tmnxMcmHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxMcmSlotNum OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..16)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value which identifies this MDA slot within a specific
|
|
IOM card in the system. Since the MCM occupies two MDA slots in
|
|
the chassis this value can only be an odd number."
|
|
::= { tmnxMcmEntry 1 }
|
|
|
|
tmnxMcmSupportedTypes OBJECT-TYPE
|
|
SYNTAX TmnxMcmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that specifies what MCM types can be physically supported
|
|
in this chassis."
|
|
::= { tmnxMcmEntry 2 }
|
|
|
|
tmnxMcmAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxMcmType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the administratively assigned
|
|
(pre-provisioned) MCM type that should occupy this chassis.
|
|
If tmnxMcmAssignedType has a value of 'unassigned',
|
|
this slot has not yet been pre-provisioned. There must not be more
|
|
than one bit set at a time in tmnxMcmAssignedType."
|
|
DEFVAL { 1 }
|
|
::= { tmnxMcmEntry 3 }
|
|
|
|
tmnxMcmEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxMcmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit-mask that identifies the MCM type that is physically
|
|
inserted into this chassis. If the chassis has been pre-provisioned,
|
|
tmnxMcmAssignedType is not equal 'unassigned', and the
|
|
value of tmnxMcmEquippedType is not the same as
|
|
tmnxMcmAssignedType, a mis-match alarm will be raised.
|
|
If the chassis has not been pre-provisioned, and the value of
|
|
tmnxMcmEquippedType is not one of the supported types as
|
|
specified by tmnxMcmSupportedTypes, a mis-match alarm will
|
|
be raised. There will not be more than one bit set at a time in
|
|
tmnxMcmEquippedType."
|
|
::= { tmnxMcmEntry 4 }
|
|
|
|
tmnxMcmHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxMcmHwIndex is the index into the
|
|
tmnxHwTable for the row entry that represents the hardware component
|
|
information for this MCM."
|
|
::= { tmnxMcmEntry 5 }
|
|
|
|
--
|
|
-- Mda Carrier Module Type (MCM) Definition Table
|
|
--
|
|
tmnxMcmTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxMcmTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The card type table has an entry for each Alcatel 7710 series
|
|
Mda Carrier Module (MCM) model."
|
|
::= { tmnxCardObjs 16 }
|
|
|
|
tmnxMcmTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxMcmTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Alcatel 7710 series MCM model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxMcmTypeIndex }
|
|
::= { tmnxMcmTypeTable 1 }
|
|
|
|
TmnxMcmTypeEntry ::=
|
|
SEQUENCE {
|
|
tmnxMcmTypeIndex TmnxMcmType,
|
|
tmnxMcmTypeName TNamedItemOrEmpty,
|
|
tmnxMcmTypeDescription TItemDescription,
|
|
tmnxMcmTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxMcmTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxMcmType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Alcatel
|
|
7710 series MCM model."
|
|
::= { tmnxMcmTypeEntry 1 }
|
|
|
|
tmnxMcmTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Alcatel
|
|
7710 series MCM model. This name string may be used in CLI
|
|
commands to specify a particular card model type."
|
|
::= { tmnxMcmTypeEntry 2 }
|
|
|
|
tmnxMcmTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Alcatel 7710 series MCM model."
|
|
::= { tmnxMcmTypeEntry 3 }
|
|
|
|
tmnxMcmTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxMcmTypeStatus has a value of 'true' it
|
|
indicates that this MCM is supported in this revision of the
|
|
management software. When it has a value of 'false' there is no
|
|
support."
|
|
::= { tmnxMcmTypeEntry 4 }
|
|
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- Notification Definition section
|
|
--
|
|
-- Notification Objects
|
|
--
|
|
|
|
tmnxEqNotificationRow OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"used by tmnx chassis Notifications, the OID
|
|
indicates the table and entry."
|
|
::= { tmnxChassisNotificationObjects 1 }
|
|
|
|
tmnxEqTypeNotificationRow OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"used by tmnx chassis notifications, the OID indicates the
|
|
table and entry with the equipment model type information."
|
|
::= { tmnxChassisNotificationObjects 2 }
|
|
|
|
tmnxChassisNotifyChassisId OBJECT-TYPE
|
|
SYNTAX TmnxChassisIndex
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnx chassis and port Notifications, indicates the chassis
|
|
associated with the alarm."
|
|
::= { tmnxChassisNotificationObjects 3 }
|
|
|
|
tmnxChassisNotifyHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnx chassis and port Notifications, indicates the entry
|
|
in the tmnxHwTable for the hardware component associated with an
|
|
alarm."
|
|
::= { tmnxChassisNotificationObjects 4 }
|
|
|
|
tmnxRedSecondaryCPMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online (1),
|
|
offline (2),
|
|
fail (3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by the tmnxRedSecondaryCPMStatusChange Notification, indicates
|
|
the status of the secondary CPM."
|
|
::= { tmnxChassisNotificationObjects 5 }
|
|
|
|
tmnxChassisNotifyOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by the tmnxChassisNotificationClear trap, the OID
|
|
identifies the trap which is getting cleared."
|
|
::= { tmnxChassisNotificationObjects 6 }
|
|
|
|
tmnxSyncIfTimingNotifyAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notUsed (0),
|
|
los (1),
|
|
oof (2),
|
|
oopir (3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnx Synchronous interface timing notifications, the value of
|
|
tmnxSyncIfTimingNotifyAlarm indicates the reason a timing reference
|
|
alarm has been raised."
|
|
::= { tmnxChassisNotificationObjects 7 }
|
|
|
|
tmnxChassisNotifyMismatchedVer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnxPeSoftwareVersionMismatch, the value of
|
|
tmnxChassisNotifyMismatchedVer indicates the software version of the
|
|
mismatched CPM/IOM card."
|
|
::= { tmnxChassisNotificationObjects 8 }
|
|
|
|
tmnxChassisNotifySoftwareLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnxPeSoftwareLoadFailed, the value of
|
|
tmnxChassisNotifySoftwareLocation contains the location of the
|
|
software."
|
|
::= { tmnxChassisNotificationObjects 9 }
|
|
|
|
tmnxChassisNotifyCardFailureReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnxEqCardFailure, the value of
|
|
tmnxChassisNotifyCardFailureReason contains the
|
|
reason for card failure."
|
|
::= { tmnxChassisNotificationObjects 10 }
|
|
|
|
tmnxChassisNotifyCardName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..32))
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used by tmnxEqCardInserted and tmnxEqCardRemoved, the value
|
|
of tmnxChassisNotifyCardName specifies the name of the affected
|
|
card."
|
|
::= { tmnxChassisNotificationObjects 11 }
|
|
|
|
--
|
|
-- ALCATEL-IND1-TIMETRA-CHASSIS-MIB Notifications
|
|
--
|
|
|
|
--
|
|
-- Hardware Configuration Change Alarm
|
|
--
|
|
tmnxHwConfigChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A tmnxHwConfigChange notification is generated when the value of
|
|
tmnxHwLastChange is updated. It can be used by the NMS to trigger
|
|
maintenance polls of the hardware configuration information.
|
|
|
|
Only one tmnxHwConfigChange notification event will be generated
|
|
in a 5 second throttling time period. A notification event is
|
|
the transmission of a single trap to a list of notification
|
|
destinations configured in the SNMP-TARGET-MIB.
|
|
|
|
If additional hardware configuration change occurs within the
|
|
throttling period, the notification events for these changes are
|
|
suppressed until the throttling period expires. At the end of
|
|
the throttling period, one notification event is generated if
|
|
any addition configuration changes occurred within the just
|
|
completed throttling period and another throttling period is
|
|
started.
|
|
|
|
The NMS should periodically check the value of tmnxHwConfigChange
|
|
to detect any missed tmnxHwConfigChange traps.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
The tmnxHwConfigChange notification has been replaced
|
|
with the generic change notifications from the
|
|
TIMETRA-SYSTEM-MIB: tmnxConfigModify, tmnxConfigCreate,
|
|
tmnxConfigDelete, tmnxStateChange."
|
|
::= { tmnxChassisNotification 1 }
|
|
|
|
|
|
--
|
|
-- Environmental Alarms
|
|
--
|
|
tmnxEnvTempTooHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxHwTemperature,
|
|
tmnxHwTempThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the temperature sensor reading on an equipment
|
|
object is greater than its configured threshold."
|
|
::= { tmnxChassisNotification 2 }
|
|
|
|
--
|
|
-- Equipment Alarms
|
|
--
|
|
|
|
tmnxEqPowerSupplyFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisPowerSupplyACStatus,
|
|
tmnxChassisPowerSupplyDCStatus,
|
|
tmnxChassisPowerSupplyTempStatus,
|
|
tmnxChassisPowerSupplyTempThreshold,
|
|
tmnxChassisPowerSupply1Status,
|
|
tmnxChassisPowerSupply2Status,
|
|
tmnxChassisPowerSupplyInputStatus,
|
|
tmnxChassisPowerSupplyOutputStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when one of the chassis's power supplies fails."
|
|
::= { tmnxChassisNotification 3 }
|
|
|
|
tmnxEqPowerSupplyInserted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when one of the chassis's power supplies is inserted."
|
|
::= { tmnxChassisNotification 4 }
|
|
|
|
tmnxEqPowerSupplyRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when one of the chassis's power supplies is removed."
|
|
::= { tmnxChassisNotification 5 }
|
|
|
|
tmnxEqFanFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisFanOperStatus,
|
|
tmnxChassisFanSpeed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when one of the fans in a fan tray has failed."
|
|
::= { tmnxChassisNotification 6 }
|
|
|
|
tmnxEqCardFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxHwOperState,
|
|
tmnxChassisNotifyCardFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when one of the cards in a chassis has failed. The card
|
|
type may be IOM, Fabric, MDA, MCM, CCM, CPM module, compact flash
|
|
module, etc. tmnxChassisNotifyCardFailureReason contains the reason
|
|
for card failure."
|
|
::= { tmnxChassisNotification 7 }
|
|
|
|
tmnxEqCardInserted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyCardName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when a card is inserted into the chassis. The card type
|
|
may be IOM, Fabric, MDA, MCM, CCM CPM module, compact flash module,
|
|
etc."
|
|
::= { tmnxChassisNotification 8 }
|
|
|
|
tmnxEqCardRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyCardName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when a card is removed from the chassis. The card type
|
|
may be IOM, Fabric, MDA, MCM, CCM, CPM module, compact flash module,
|
|
etc."
|
|
::= { tmnxChassisNotification 9 }
|
|
|
|
tmnxEqWrongCard NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the wrong type of card is inserted into a slot of
|
|
the chassis. Even though a card may be physically supported by
|
|
the slot, it may have been administratively configured to allow
|
|
only certain card types in a particular slot location. The card
|
|
type may be IOM, Fabric, MDA, MCM, CPM module, etc."
|
|
::= { tmnxChassisNotification 10 }
|
|
|
|
tmnxEqCpuFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when a failure is detected for a CPU on an IOM card or
|
|
CPM module.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
A cpu failure on a CPM card is detected by the hardware
|
|
bootup and is indicated by the boot diagnostic display.
|
|
If there is no working redundant CPM card, the system
|
|
does not come up.
|
|
|
|
A failure of an IOM card or standby redundant CPM card
|
|
causes the tmnxEqCardFailure notification to be sent."
|
|
::= { tmnxChassisNotification 11 }
|
|
|
|
tmnxEqMemoryFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when a memory module failure is detected for an IOM card or
|
|
CPM module.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
A failure of the memory device is detected by the
|
|
hardware bootup and is indicated by the boot diagnostic
|
|
display. If there is no working redundant CPM card,
|
|
the system does not come up.
|
|
|
|
A failure of the memory device during run-time causes
|
|
the system to fail and the 'admin tech-support'
|
|
information to be saved.
|
|
|
|
A failure of an IOM card or standby redundant CPM card
|
|
causes the tmnxEqCardFailure notification to be sent."
|
|
::= { tmnxChassisNotification 12 }
|
|
|
|
tmnxEqBackdoorBusFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyChassisId
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when the backdoor bus has failed.
|
|
|
|
This notification was made obsolete in the 2.1 release."
|
|
::= { tmnxChassisNotification 13 }
|
|
|
|
--
|
|
-- Processing Error Alarms
|
|
--
|
|
|
|
tmnxPeSoftwareError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when a software error has been detected.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
Many of the other notifications more specifically
|
|
indicate detection of some type of software error.
|
|
|
|
The 'admin tech-support' information helps developers
|
|
diagnose a failure of the software in the field."
|
|
::= { tmnxChassisNotification 14 }
|
|
|
|
tmnxPeSoftwareAbnormalHalt NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when the software has abnormally terminated.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
Many of the other notifications more specifically
|
|
indicate detection of some type of software error.
|
|
|
|
The 'admin tech-support' information helps developers
|
|
diagnose a failure of the software in the field."
|
|
::= { tmnxChassisNotification 15 }
|
|
|
|
tmnxPeSoftwareVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyMismatchedVer,
|
|
tmnxHwSoftwareCodeVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when there is a mismatch between software versions of the
|
|
active CPM and standby CPM or the CPM and IOM.
|
|
tmnxChassisNotifyHwIndex identifies the mismatched CPM/IOM card and
|
|
tmnxChassisNotifyMismatchedVer will contain the version of the
|
|
mismatched card. The tmnxHwSoftwareCodeVersion object will contain
|
|
the expected version."
|
|
::= { tmnxChassisNotification 16 }
|
|
|
|
tmnxPeOutOfMemory NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when there is an out of memory error detected.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
The tmnxPeOutOfMemory notification has been replaced
|
|
with the module specific notification from the
|
|
TIMETRA-SYSTEM-MIB: tmnxModuleMallocFailed."
|
|
::= { tmnxChassisNotification 17 }
|
|
|
|
tmnxPeConfigurationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when a configuration error has been detected.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
Many other notifications more specifically indicate
|
|
detection of a configuration error. In most cases the
|
|
SNMP SET request that tries to make an invalid
|
|
configuration results in an error response.
|
|
|
|
In some cases the configuration parameters are valid
|
|
and the SNMP SET request succeeds but the system cannot
|
|
successfully apply the new parameters. The affected
|
|
object may then put into an operational 'down' state.
|
|
A state change notification such as tmnxStateChange or
|
|
a more specific notification is sent to alert about the
|
|
problem.
|
|
|
|
For example, an attempt to create an event log with a
|
|
file-type destination when the specified cflash media is
|
|
full or not present results in TIMETRA-LOG-MIB
|
|
notifications tmnxLogSpaceContention, tmnxLogAdminLocFailed,
|
|
or tmnxLogBackupLocFailed."
|
|
::= { tmnxChassisNotification 18 }
|
|
|
|
tmnxPeStorageProblem NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when there is a storage capacity problem.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
The only 'storage' devices on the SR7750 are the cflash
|
|
drives. Cflash write errors cause a tmnxEqFlashDataLoss
|
|
notification to be sent. The tmnxEqFlashDiskFull
|
|
notification is sent when the driver detects that the
|
|
cflash device is full."
|
|
::= { tmnxChassisNotification 19 }
|
|
|
|
tmnxPeCpuCyclesExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when the CPU cycle usage limit has been exceeded.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
It does not apply. The SR7750 software architecture does
|
|
not restrict CPU cycles used by a specific code module."
|
|
::= { tmnxChassisNotification 20 }
|
|
|
|
--
|
|
-- Redundancy notifications
|
|
--
|
|
|
|
tmnxRedPrimaryCPMFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the primary CPM fails."
|
|
::= { tmnxChassisNotification 21 }
|
|
|
|
tmnxRedSecondaryCPMStatusChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxRedSecondaryCPMStatus
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when there is a change in the secondary CPM status.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
There is no way to administratively enable or disable
|
|
CPM cards so there is no need for a status change event
|
|
for administrative state changes.
|
|
|
|
Operational changes detected about the standby CPM
|
|
card are indicated by more specific notifications such
|
|
as tmnxEqCardFailure, tmnxEqCardRemoved, tmnxEqCardInserted
|
|
TIMETRA-SYSTEM-MIB::ssiRedStandbyReady,
|
|
TIMETRA-SYSTEM-MIB::ssiRedStandbySyncLost, and
|
|
TIMETRA-SYSTEM-MIB::ssiRedStandbySyncLost."
|
|
::= { tmnxChassisNotification 22 }
|
|
|
|
tmnxRedRestoreSuccess NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when the secondary CPM successfully restores
|
|
the config and state.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
It does not apply. This event was originally created
|
|
for an early redundancy mechanism that was never
|
|
released."
|
|
::= { tmnxChassisNotification 23 }
|
|
|
|
tmnxRedRestoreFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Generated when the secondary CPM fails to
|
|
restore the config and state.
|
|
|
|
This notification was made obsolete in the 2.1 release.
|
|
|
|
It does not apply. This event was originally created
|
|
for an early redundancy mechanism that was never
|
|
released."
|
|
::= { tmnxChassisNotification 24 }
|
|
|
|
--
|
|
-- Chassis Clear Alarm
|
|
--
|
|
|
|
tmnxChassisNotificationClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyOID
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A trap indicating the clear of a chassis notification
|
|
identified by tmnxChassisNotifyOID."
|
|
::= { tmnxChassisNotification 25 }
|
|
|
|
--
|
|
-- Synchronous timing alarms
|
|
--
|
|
|
|
tmnxEqSyncIfTimingHoldover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the synchronous equipment timing subsystem
|
|
transitions into a holdover state.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 26 }
|
|
|
|
tmnxEqSyncIfTimingHoldoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the synchronous equipment timing subsystem
|
|
transitions out of the holdover state.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 27 }
|
|
|
|
tmnxEqSyncIfTimingRef1Alarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the first timing
|
|
reference is detected.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 28 }
|
|
|
|
tmnxEqSyncIfTimingRef1AlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the first timing
|
|
reference is cleared.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 29 }
|
|
|
|
tmnxEqSyncIfTimingRef2Alarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the second timing
|
|
reference is detected.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 30 }
|
|
|
|
tmnxEqSyncIfTimingRef2AlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the second timing
|
|
reference is cleared.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 31 }
|
|
|
|
tmnxEqFlashDataLoss NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxHwOperState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxEqFlashDataLoss is generated when there was an error
|
|
while data was getting written on to the compact flash. This
|
|
notification indicates a probable data loss."
|
|
::= { tmnxChassisNotification 32 }
|
|
|
|
tmnxEqFlashDiskFull NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxHwOperState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxEqFlashDiskFull is generated when there is no space
|
|
left on the compact flash. No more data can be written to it."
|
|
::= { tmnxChassisNotification 33 }
|
|
|
|
tmnxPeSoftwareLoadFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifySoftwareLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when the CPM fails to load the software from a specified
|
|
location.
|
|
tmnxChassisNotifyHwIndex identifies the card for which the software
|
|
load failed and tmnxChassisNotifySoftwareLocation contains the
|
|
location from where the software load was attempted."
|
|
::= { tmnxChassisNotification 34 }
|
|
|
|
tmnxPeBootloaderVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyMismatchedVer,
|
|
tmnxHwSoftwareCodeVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when there is a mismatch between the CPM and boot loader
|
|
versions. tmnxChassisNotifyHwIndex identifies the CPM card.
|
|
tmnxChassisNotifyMismatchedVer contains the mismatched version of
|
|
bootloader and tmnxHwSoftwareCodeVersion contains the
|
|
expected version of the bootloader."
|
|
::= { tmnxChassisNotification 35 }
|
|
|
|
tmnxPeBootromVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyMismatchedVer,
|
|
tmnxHwSoftwareCodeVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when there is a mismatch between the boot rom versions.
|
|
tmnxChassisNotifyHwIndex identifies the IOM card.
|
|
tmnxChassisNotifyMismatchedVer contains the mismatched version of
|
|
bootrom and tmnxHwSoftwareCodeVersion contains the expected version
|
|
of the bootrom."
|
|
::= { tmnxChassisNotification 36 }
|
|
|
|
tmnxPeFPGAVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxChassisNotifyMismatchedVer,
|
|
tmnxHwSoftwareCodeVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when there is a mismatch between the FPGA versions.
|
|
tmnxChassisNotifyHwIndex identifies the IOM card.
|
|
tmnxChassisNotifyMismatchedVer contains the mismatched version of
|
|
FPGA and tmnxHwSoftwareCodeVersion contains the expected version
|
|
of the FPGA."
|
|
::= { tmnxChassisNotification 37 }
|
|
|
|
tmnxEqSyncIfTimingBITSAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the BITS timing
|
|
reference is detected.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 38 }
|
|
|
|
tmnxEqSyncIfTimingBITSAlarmClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass,
|
|
tmnxSyncIfTimingNotifyAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when an alarm condition on the BITS timing
|
|
reference is cleared.
|
|
This notification will have the same indices as those of
|
|
the tmnxCpmCardTable."
|
|
::= { tmnxChassisNotification 39 }
|
|
|
|
tmnxEqCardFirmwareUpgraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when a card is hot-inserted into the chassis and its
|
|
firmware is automatically upgraded. The card type may be IOM or
|
|
CPM module."
|
|
::= { tmnxChassisNotification 40 }
|
|
|
|
tmnxChassisUpgradeInProgress NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxChassisUpgradeInProgress notification is generated only
|
|
after a CPM switchover occurs and the new active CPM is running new
|
|
software, while the IOMs are still running old software. This is the
|
|
start of the upgrade process. The tmnxChassisUpgradeInProgress
|
|
notification will continue to be generated every 30 minutes while at
|
|
least one IOM is still running older software."
|
|
::= { tmnxChassisNotification 41 }
|
|
|
|
tmnxChassisUpgradeComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxChassisUpgradeComplete notification is generated to
|
|
indicate that all the IOMs are running matching software version in
|
|
reference to the active CPM software version changed as part of the
|
|
upgrade process."
|
|
::= { tmnxChassisNotification 42 }
|
|
|
|
tmnxChassisHiBwMcastAlarm NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxChassisHiBwMcastAlarm notification is generated when a plane
|
|
is shared by more than one high bandwidth multicast tap."
|
|
::= { tmnxChassisNotification 43 }
|
|
|
|
tmnxEqMdaCfgNotCompatible NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxHwID,
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generated when a supported MDA is inserted into a slot of an
|
|
IOM, the MDA is compatible with the currently provisioned
|
|
MDA, but the current configuration on the MDA's ports is not
|
|
compatible with the inserted MDA."
|
|
::= { tmnxChassisNotification 44 }
|
|
|
|
--
|
|
--
|
|
--
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TMNX-HW-MIB Object Groups
|
|
--
|
|
|
|
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- The compliance specifications.
|
|
--
|
|
|
|
tmnxChassisCompliances OBJECT IDENTIFIER ::= { tmnxChassisConformance 1 }
|
|
tmnxChassisGroups OBJECT IDENTIFIER ::= { tmnxChassisConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
-- tmnxChassisCompliance MODULE-COMPLIANCE
|
|
-- ::= { tmnxChassisCompliances 1 }
|
|
|
|
-- tmnxChassisR2r1Compliance MODULE-COMPLIANCE
|
|
-- ::= { tmnxChassisCompliances 2 }
|
|
|
|
-- tmnxChassisV3v0Compliance MODULE-COMPLIANCE
|
|
-- ::= { tmnxChassisCompliances 3 }
|
|
|
|
tmnxChassisV4v0Compliance MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV3v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxChassisNotificationV4v0Group
|
|
}
|
|
::= { tmnxChassisCompliances 4 }
|
|
|
|
tmnxChassisV5v0Compliance MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV5v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxChassisNotificationV4v0Group
|
|
}
|
|
::= { tmnxChassisCompliances 6 }
|
|
|
|
tmnxChassis7750V6v0Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
on the 7750 in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV5v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxChassisNotificationV6v0Group,
|
|
tmnx77x0CESMDAV6v0Group,
|
|
tmnxCardV6v0NamedPoolPlcyGroup,
|
|
-- tmnx7710HwV3v0Group
|
|
-- tmnx7710SETSRefSrcHwV6v0Group
|
|
tmnxMDAMcPathMgmtV6v0Group
|
|
}
|
|
::= { tmnxChassisCompliances 7 }
|
|
|
|
tmnxChassis7450V6v0Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
on the 7450 in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV5v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxCardV6v0NamedPoolPlcyGroup,
|
|
tmnxChassisNotificationV6v0Group,
|
|
-- tmnx77x0CESMDAV6v0Group
|
|
-- tmnx7710HwV3v0Group
|
|
-- tmnx7710SETSRefSrcHwV6v0Group
|
|
tmnxMDAMcPathMgmtV6v0Group
|
|
}
|
|
::= { tmnxChassisCompliances 8 }
|
|
|
|
tmnxChassisComp7710 OBJECT IDENTIFIER ::= { tmnxChassisCompliances 5 }
|
|
|
|
tmnxChassisComp7710V3v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
for the 7710 in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV3v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV3v0Group,
|
|
tmnxChassisNotificationV3v0Group,
|
|
tmnx7710HwV3v0Group
|
|
}
|
|
::= { tmnxChassisComp7710 1 }
|
|
|
|
tmnxChassisComp7710V5v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
for the 7710 in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV5v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxChassisNotificationV4v0Group,
|
|
tmnx7710HwV3v0Group
|
|
}
|
|
::= { tmnxChassisComp7710 2 }
|
|
|
|
tmnxChassisComp7710V6v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for management of chassis features
|
|
for the 7710 in the ALCATEL-IND1-TIMETRA-CHASSIS-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxChassisV5v0Group,
|
|
tmnxCardV3v0Group,
|
|
tmnxMDAV4v0Group,
|
|
tmnxChassisNotificationV6v0Group,
|
|
tmnx7710HwV3v0Group,
|
|
tmnx77x0CESMDAV6v0Group,
|
|
tmnx7710SETSRefSrcHwV6v0Group,
|
|
tmnxCardV6v0NamedPoolPlcyGroup,
|
|
tmnxMDAMcPathMgmtV6v0Group
|
|
}
|
|
::= { tmnxChassisComp7710 3 }
|
|
|
|
-- units of conformance
|
|
|
|
-- tmnxChassisGroup OBJECT-GROUP
|
|
-- ::= { tmnxChassisGroups 1 }
|
|
|
|
-- tmnxCardGroup OBJECT-GROUP
|
|
-- ::= { tmnxChassisGroups 2 }
|
|
|
|
-- tmnxMDAGroup OBJECT-GROUP
|
|
-- ::= { tmnxChassisGroups 3 }
|
|
|
|
tmnxChassisNotifyObjsGroup OBJECT-GROUP
|
|
OBJECTS { tmnxEqNotificationRow,
|
|
tmnxEqTypeNotificationRow,
|
|
tmnxChassisNotifyChassisId,
|
|
tmnxChassisNotifyHwIndex,
|
|
tmnxRedSecondaryCPMStatus,
|
|
tmnxChassisNotifyOID,
|
|
tmnxSyncIfTimingNotifyAlarm,
|
|
tmnxChassisNotifyMismatchedVer,
|
|
tmnxChassisNotifySoftwareLocation,
|
|
tmnxChassisNotifyCardFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting chassis hardware notifications
|
|
on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 4 }
|
|
|
|
-- tmnxChassisNotificationGroup NOTIFICATION-GROUP
|
|
-- ::= { tmnxChassisGroups 5 }
|
|
|
|
-- tmnxChassisNotificationR2r1Group NOTIFICATION-GROUP
|
|
-- ::= { tmnxChassisGroups 6 }
|
|
|
|
tmnxChassisNotifyObsoleteGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tmnxHwConfigChange,
|
|
tmnxEqCpuFailure,
|
|
tmnxEqMemoryFailure,
|
|
tmnxEqBackdoorBusFailure,
|
|
tmnxPeSoftwareError,
|
|
tmnxPeSoftwareAbnormalHalt,
|
|
tmnxPeOutOfMemory,
|
|
tmnxPeConfigurationError,
|
|
tmnxPeStorageProblem,
|
|
tmnxPeCpuCyclesExceeded,
|
|
tmnxRedSecondaryCPMStatusChange,
|
|
tmnxRedRestoreSuccess,
|
|
tmnxRedRestoreFail
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notifications supporting the management of chassis
|
|
hardware made obsolete for revision 2.1 on Alcatel 7x50 SR series
|
|
systems."
|
|
::= { tmnxChassisGroups 7 }
|
|
|
|
-- tmnxChassisR2r1Group OBJECT-GROUP
|
|
-- ::= { tmnxChassisGroups 8 }
|
|
|
|
tmnxChassisV3v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxChassisTotalNumber,
|
|
tmnxChassisLastChange,
|
|
tmnxChassisRowStatus,
|
|
tmnxChassisName,
|
|
tmnxChassisType,
|
|
tmnxChassisLocation,
|
|
tmnxChassisCoordinates,
|
|
tmnxChassisNumSlots,
|
|
tmnxChassisNumPorts,
|
|
tmnxChassisNumPwrSupplies,
|
|
tmnxChassisNumFanTrays,
|
|
tmnxChassisNumFans,
|
|
tmnxChassisCriticalLEDState,
|
|
tmnxChassisMajorLEDState,
|
|
tmnxChassisMinorLEDState,
|
|
tmnxChassisBaseMacAddress,
|
|
tmnxChassisCLLICode,
|
|
tmnxChassisReboot,
|
|
tmnxChassisUpgrade,
|
|
tmnxChassisAdminMode,
|
|
tmnxChassisOperMode,
|
|
tmnxChassisModeForce,
|
|
tmnxChassisUpdateWaitTime,
|
|
tmnxChassisUpdateTimeLeft,
|
|
tmnxChassisFanOperStatus,
|
|
tmnxChassisFanSpeed,
|
|
tmnxChassisPowerSupplyACStatus,
|
|
tmnxChassisPowerSupplyDCStatus,
|
|
tmnxChassisPowerSupplyTempStatus,
|
|
tmnxChassisPowerSupplyTempThreshold,
|
|
tmnxChassisPowerSupply1Status,
|
|
tmnxChassisPowerSupply2Status,
|
|
tmnxChassisPowerSupplyAssignedType,
|
|
tmnxChassisTypeName,
|
|
tmnxChassisTypeDescription,
|
|
tmnxChassisTypeStatus,
|
|
tmnxHwLastChange,
|
|
tmnxHwID,
|
|
tmnxHwMfgString,
|
|
tmnxHwMfgBoardNumber,
|
|
tmnxHwSerialNumber,
|
|
tmnxHwManufactureDate,
|
|
tmnxHwClass,
|
|
tmnxHwName,
|
|
tmnxHwAlias,
|
|
tmnxHwAssetID,
|
|
tmnxHwCLEI,
|
|
tmnxHwIsFRU,
|
|
tmnxHwContainedIn,
|
|
tmnxHwParentRelPos,
|
|
tmnxHwAdminState,
|
|
tmnxHwOperState,
|
|
tmnxHwTempSensor,
|
|
tmnxHwTemperature,
|
|
tmnxHwTempThreshold,
|
|
tmnxHwBootCodeVersion,
|
|
tmnxHwSoftwareCodeVersion,
|
|
tmnxHwSwLastBoot,
|
|
tmnxHwAlarmState,
|
|
tmnxHwLastAlarmEvent,
|
|
tmnxHwClearAlarms,
|
|
tmnxHwSwImageSource,
|
|
tmnxHwMfgDeviations,
|
|
tmnxHwBaseMacAddress,
|
|
tmnxHwFailureReason,
|
|
tmnxHwContainedIndex
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of objects supporting management of chassis hardware
|
|
capabilities on release 3.0 of Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 9 }
|
|
|
|
tmnxMDAV3v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxMDASupportedTypes,
|
|
tmnxMDAAssignedType,
|
|
tmnxMDAEquippedType,
|
|
tmnxMDAHwIndex,
|
|
tmnxMDAMaxPorts,
|
|
tmnxMDAEquippedPorts,
|
|
tmnxMDATxTimingSelected,
|
|
tmnxMDASyncIfTimingStatus,
|
|
tmnxMDANetworkIngQueues,
|
|
tmnxMDACapabilities,
|
|
tmnxMDAMinChannelization,
|
|
tmnxMDAMaxChannelization,
|
|
tmnxMDAMaxChannels,
|
|
tmnxMDAChannelsInUse,
|
|
tmnxMDACcagId,
|
|
tmnxMdaTypeName,
|
|
tmnxMdaTypeDescription,
|
|
tmnxMdaTypeStatus,
|
|
tmnxCcagRowStatus,
|
|
tmnxCcagDescription,
|
|
tmnxCcagAdminStatus,
|
|
tmnxCcagOperStatus,
|
|
tmnxCcagCcaRate,
|
|
tmnxCcagLastChanged,
|
|
tmnxCcagAccessAdaptQos,
|
|
tmnxCcagPathLastChanged,
|
|
tmnxCcagPathRate,
|
|
tmnxCcagPathRateOption,
|
|
tmnxCcagPathWeight,
|
|
tmnxCcagPathCcLastChanged,
|
|
tmnxCcagPathCcEgrPoolResvCbs,
|
|
tmnxCcagPathCcEgrPoolSlpPlcy,
|
|
tmnxCcagPathCcIngPoolResvCbs,
|
|
tmnxCcagPathCcIngPoolSlpPlcy,
|
|
tmnxCcagPathCcAcctPolicyId,
|
|
tmnxCcagPathCcCollectStats,
|
|
tmnxCcagPathCcQueuePlcy,
|
|
tmnxCcagPathCcMac,
|
|
tmnxCcagPathCcMtu,
|
|
tmnxCcagPathCcHwMac,
|
|
tmnxCcagPathCcUserAssignedMac
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of objects supporting management of MDAs on
|
|
Alcatel 7x50 SR series systems."
|
|
|
|
::= { tmnxChassisGroups 10 }
|
|
|
|
tmnxChassisObsoleteGroup OBJECT-GROUP
|
|
OBJECTS { tmnxHwSwState,
|
|
tmnxCardAllowedTypes,
|
|
tmnxCpmCardAllowedTypes,
|
|
tmnxMDAAllowedTypes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the allowed types of CPM cards, IOM
|
|
cards and MDA made obsolete for revision 3.0 on Alcatel 7x50 SR series
|
|
systems."
|
|
::= { tmnxChassisGroups 11 }
|
|
|
|
tmnxCardV3v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxCardLastChange,
|
|
tmnxCardTypeName,
|
|
tmnxCardTypeDescription,
|
|
tmnxCardTypeStatus,
|
|
tmnxCardSupportedTypes,
|
|
tmnxCardAssignedType,
|
|
tmnxCardEquippedType,
|
|
tmnxCardHwIndex,
|
|
tmnxCardClockSource,
|
|
tmnxCardNumMdaSlots,
|
|
tmnxCardNumMdas,
|
|
tmnxCardReboot,
|
|
tmnxCardMemorySize,
|
|
tmnxCpmCardLastChange,
|
|
tmnxCpmCardSupportedTypes,
|
|
tmnxCpmCardAssignedType,
|
|
tmnxCpmCardEquippedType,
|
|
tmnxCpmCardHwIndex,
|
|
tmnxCpmCardBootOptionVersion,
|
|
tmnxCpmCardBootOptionLastModified,
|
|
tmnxCpmCardConfigBootedVersion,
|
|
tmnxCpmCardIndexBootedVersion,
|
|
tmnxCpmCardConfigLastModified,
|
|
tmnxCpmCardConfigLastSaved,
|
|
tmnxCpmCardRedundant,
|
|
tmnxCpmCardClockSource,
|
|
tmnxCpmCardNumCpus,
|
|
tmnxCpmCardCpuType,
|
|
tmnxCpmCardMemorySize,
|
|
tmnxCpmCardSwitchToRedundantCard,
|
|
tmnxCpmCardReboot,
|
|
tmnxCpmCardRereadBootOptions,
|
|
tmnxCpmCardConfigFileLastBooted,
|
|
tmnxCpmCardConfigFileLastSaved,
|
|
tmnxCpmCardConfigFileLastBootedHeader,
|
|
tmnxCpmCardIndexFileLastBootedHeader,
|
|
tmnxCpmCardBootOptionSource,
|
|
tmnxCpmCardConfigSource,
|
|
tmnxCpmCardBootOptionLastSaved,
|
|
tmnxFabricLastChange,
|
|
tmnxFabricAssignedType,
|
|
tmnxFabricEquippedType,
|
|
tmnxFabricHwIndex,
|
|
tmnxCpmFlashOperStatus,
|
|
tmnxCpmFlashSerialNumber,
|
|
tmnxCpmFlashFirmwareRevision,
|
|
tmnxCpmFlashModelNumber,
|
|
tmnxCpmFlashCapacity,
|
|
tmnxCpmFlashUsed,
|
|
tmnxCpmFlashHwIndex,
|
|
tmnxSyncIfTimingRevert,
|
|
tmnxSyncIfTimingRefOrder1,
|
|
tmnxSyncIfTimingRefOrder2,
|
|
tmnxSyncIfTimingRef1SrcPort,
|
|
tmnxSyncIfTimingRef1AdminStatus,
|
|
tmnxSyncIfTimingRef1InUse,
|
|
tmnxSyncIfTimingRef1Qualified,
|
|
tmnxSyncIfTimingRef1Alarm,
|
|
tmnxSyncIfTimingRef2SrcPort,
|
|
tmnxSyncIfTimingRef2AdminStatus,
|
|
tmnxSyncIfTimingRef2InUse,
|
|
tmnxSyncIfTimingRef2Qualified,
|
|
tmnxSyncIfTimingRef2Alarm,
|
|
tmnxSyncIfTimingFreqOffset,
|
|
tmnxSyncIfTimingStatus,
|
|
tmnxSyncIfTimingRefOrder3,
|
|
tmnxSyncIfTimingBITSIfType,
|
|
tmnxSyncIfTimingBITSAdminStatus,
|
|
tmnxSyncIfTimingBITSInUse,
|
|
tmnxSyncIfTimingBITSQualified,
|
|
tmnxSyncIfTimingBITSAlarm,
|
|
tSyncIfTimingAdmRevert,
|
|
tSyncIfTimingAdmRefOrder1,
|
|
tSyncIfTimingAdmRefOrder2,
|
|
tSyncIfTimingAdmRef1SrcPort,
|
|
tSyncIfTimingAdmRef1AdminStatus,
|
|
tSyncIfTimingAdmRef2SrcPort,
|
|
tSyncIfTimingAdmRef2AdminStatus,
|
|
tSyncIfTimingAdmChanged,
|
|
tSyncIfTimingAdmRefOrder3,
|
|
tSyncIfTimingAdmBITSIfType,
|
|
tSyncIfTimingAdmBITSAdminStatus,
|
|
tmnxChassisAdminOwner,
|
|
tmnxChassisAdminControlApply,
|
|
tmnxChassisAdminLastSetTimer,
|
|
tmnxChassisAdminLastSetTimeout
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of hardware cards
|
|
on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 12 }
|
|
|
|
tmnxMDAV4v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxMDASupportedTypes,
|
|
tmnxMDAAssignedType,
|
|
tmnxMDAEquippedType,
|
|
tmnxMDAHwIndex,
|
|
tmnxMDAMaxPorts,
|
|
tmnxMDAEquippedPorts,
|
|
tmnxMDATxTimingSelected,
|
|
tmnxMDASyncIfTimingStatus,
|
|
tmnxMDANetworkIngQueues,
|
|
tmnxMDACapabilities,
|
|
tmnxMDAMinChannelization,
|
|
tmnxMDAMaxChannelization,
|
|
tmnxMDAMaxChannels,
|
|
tmnxMDAChannelsInUse,
|
|
tmnxMDACcagId,
|
|
tmnxMdaTypeName,
|
|
tmnxMdaTypeDescription,
|
|
tmnxMdaTypeStatus,
|
|
tmnxMDAReboot,
|
|
tmnxCcagRowStatus,
|
|
tmnxCcagDescription,
|
|
tmnxCcagAdminStatus,
|
|
tmnxCcagOperStatus,
|
|
tmnxCcagCcaRate,
|
|
tmnxCcagLastChanged,
|
|
tmnxCcagAccessAdaptQos,
|
|
tmnxCcagPathLastChanged,
|
|
tmnxCcagPathRate,
|
|
tmnxCcagPathRateOption,
|
|
tmnxCcagPathWeight,
|
|
tmnxCcagPathCcLastChanged,
|
|
tmnxCcagPathCcEgrPoolResvCbs,
|
|
tmnxCcagPathCcEgrPoolSlpPlcy,
|
|
tmnxCcagPathCcIngPoolResvCbs,
|
|
tmnxCcagPathCcIngPoolSlpPlcy,
|
|
tmnxCcagPathCcAcctPolicyId,
|
|
tmnxCcagPathCcCollectStats,
|
|
tmnxCcagPathCcQueuePlcy,
|
|
tmnxCcagPathCcMac,
|
|
tmnxCcagPathCcMtu,
|
|
tmnxCcagPathCcHwMac,
|
|
tmnxCcagPathCcUserAssignedMac,
|
|
tmnxMDAHiBwMcastSource,
|
|
tmnxMDAHiBwMcastAlarm,
|
|
tmnxMDAHiBwMcastTapCount,
|
|
tmnxMDAHiBwMcastGroup
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of MDAs for release 4.0 on
|
|
Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 13 }
|
|
|
|
tmnxChassisNotificationV4v0Group NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tmnxEnvTempTooHigh,
|
|
tmnxEqPowerSupplyFailure,
|
|
tmnxEqPowerSupplyInserted,
|
|
tmnxEqPowerSupplyRemoved,
|
|
tmnxEqFanFailure,
|
|
tmnxEqCardFailure,
|
|
tmnxEqCardInserted,
|
|
tmnxEqCardRemoved,
|
|
tmnxEqWrongCard,
|
|
tmnxPeSoftwareVersionMismatch,
|
|
tmnxRedPrimaryCPMFail,
|
|
tmnxChassisNotificationClear,
|
|
tmnxEqSyncIfTimingHoldover,
|
|
tmnxEqSyncIfTimingHoldoverClear,
|
|
tmnxEqSyncIfTimingRef1Alarm,
|
|
tmnxEqSyncIfTimingRef1AlarmClear,
|
|
tmnxEqSyncIfTimingRef2Alarm,
|
|
tmnxEqSyncIfTimingRef2AlarmClear,
|
|
tmnxEqFlashDataLoss,
|
|
tmnxEqFlashDiskFull,
|
|
tmnxPeSoftwareLoadFailed,
|
|
tmnxPeBootloaderVersionMismatch,
|
|
tmnxPeBootromVersionMismatch,
|
|
tmnxPeFPGAVersionMismatch,
|
|
tmnxEqSyncIfTimingBITSAlarm,
|
|
tmnxEqSyncIfTimingBITSAlarmClear,
|
|
tmnxEqCardFirmwareUpgraded,
|
|
tmnxChassisUpgradeInProgress,
|
|
tmnxChassisUpgradeComplete,
|
|
tmnxChassisHiBwMcastAlarm,
|
|
tmnxEqMdaCfgNotCompatible
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of notifications supporting the management of chassis
|
|
hardware for release 4.0 on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 14 }
|
|
|
|
tmnx7710HwV3v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxChassisOverTempState,
|
|
tmnxCpmCardMasterSlaveRefState,
|
|
tmnxCcmOperStatus,
|
|
tmnxCcmHwIndex,
|
|
tmnxCcmEquippedType,
|
|
tmnxCcmTypeName,
|
|
tmnxCcmTypeDescription,
|
|
tmnxCcmTypeStatus,
|
|
tmnxMcmSupportedTypes,
|
|
tmnxMcmAssignedType,
|
|
tmnxMcmEquippedType,
|
|
tmnxMcmHwIndex,
|
|
tmnxMcmTypeName,
|
|
tmnxMcmTypeDescription,
|
|
tmnxMcmTypeStatus,
|
|
tmnxChassisPowerSupplyInputStatus,
|
|
tmnxChassisPowerSupplyOutputStatus,
|
|
tmnxMDAReboot
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of hardware specific to
|
|
the Alcatel 7710 SR series systems."
|
|
::= { tmnxChassisGroups 15 }
|
|
|
|
tmnxChassisV5v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxChassisTotalNumber,
|
|
tmnxChassisLastChange,
|
|
tmnxChassisRowStatus,
|
|
tmnxChassisName,
|
|
tmnxChassisType,
|
|
tmnxChassisLocation,
|
|
tmnxChassisCoordinates,
|
|
tmnxChassisNumSlots,
|
|
tmnxChassisNumPorts,
|
|
tmnxChassisNumPwrSupplies,
|
|
tmnxChassisNumFanTrays,
|
|
tmnxChassisNumFans,
|
|
tmnxChassisCriticalLEDState,
|
|
tmnxChassisMajorLEDState,
|
|
tmnxChassisMinorLEDState,
|
|
tmnxChassisBaseMacAddress,
|
|
tmnxChassisCLLICode,
|
|
tmnxChassisReboot,
|
|
tmnxChassisUpgrade,
|
|
tmnxChassisAdminMode,
|
|
tmnxChassisOperMode,
|
|
tmnxChassisModeForce,
|
|
tmnxChassisUpdateTimeLeft,
|
|
tmnxChassisFanOperStatus,
|
|
tmnxChassisFanSpeed,
|
|
tmnxChassisPowerSupplyACStatus,
|
|
tmnxChassisPowerSupplyDCStatus,
|
|
tmnxChassisPowerSupplyTempStatus,
|
|
tmnxChassisPowerSupplyTempThreshold,
|
|
tmnxChassisPowerSupply1Status,
|
|
tmnxChassisPowerSupply2Status,
|
|
tmnxChassisPowerSupplyAssignedType,
|
|
tmnxChassisTypeName,
|
|
tmnxChassisTypeDescription,
|
|
tmnxChassisTypeStatus,
|
|
tmnxHwLastChange,
|
|
tmnxHwID,
|
|
tmnxHwMfgString,
|
|
tmnxHwMfgBoardNumber,
|
|
tmnxHwSerialNumber,
|
|
tmnxHwManufactureDate,
|
|
tmnxHwClass,
|
|
tmnxHwName,
|
|
tmnxHwAlias,
|
|
tmnxHwAssetID,
|
|
tmnxHwCLEI,
|
|
tmnxHwIsFRU,
|
|
tmnxHwContainedIn,
|
|
tmnxHwParentRelPos,
|
|
tmnxHwAdminState,
|
|
tmnxHwOperState,
|
|
tmnxHwTempSensor,
|
|
tmnxHwTemperature,
|
|
tmnxHwTempThreshold,
|
|
tmnxHwBootCodeVersion,
|
|
tmnxHwSoftwareCodeVersion,
|
|
tmnxHwSwLastBoot,
|
|
tmnxHwAlarmState,
|
|
tmnxHwLastAlarmEvent,
|
|
tmnxHwClearAlarms,
|
|
tmnxHwSwImageSource,
|
|
tmnxHwMfgDeviations,
|
|
tmnxHwBaseMacAddress,
|
|
tmnxHwFailureReason,
|
|
tmnxHwContainedIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of chassis hardware
|
|
capabilities on release 5.0 of Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 16 }
|
|
|
|
tmnxChassisV5v0ObsoleteGroup OBJECT-GROUP
|
|
OBJECTS { tmnxChassisUpdateWaitTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of onbsolete objects for managing the chassis hardware
|
|
capabilities on release 5.0 of Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 17 }
|
|
|
|
tmnx77x0CESMDAV6v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxMDAClockMode,
|
|
tmnxMDADiffTimestampFreq,
|
|
tmnxMDAIngNamedPoolPolicy,
|
|
tmnxMDAEgrNamedPoolPolicy
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of CES MDAs for release 6.0
|
|
on Alcatel 77x0 SR series systems."
|
|
::= { tmnxChassisGroups 18 }
|
|
|
|
tmnxChassisNotificationV3v0Group NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tmnxEnvTempTooHigh,
|
|
tmnxEqPowerSupplyFailure,
|
|
tmnxEqPowerSupplyInserted,
|
|
tmnxEqPowerSupplyRemoved,
|
|
tmnxEqFanFailure,
|
|
tmnxEqCardFailure,
|
|
tmnxEqCardInserted,
|
|
tmnxEqCardRemoved,
|
|
tmnxEqWrongCard,
|
|
tmnxPeSoftwareVersionMismatch,
|
|
tmnxRedPrimaryCPMFail,
|
|
tmnxChassisNotificationClear,
|
|
tmnxEqSyncIfTimingHoldover,
|
|
tmnxEqSyncIfTimingHoldoverClear,
|
|
tmnxEqSyncIfTimingRef1Alarm,
|
|
tmnxEqSyncIfTimingRef1AlarmClear,
|
|
tmnxEqSyncIfTimingRef2Alarm,
|
|
tmnxEqSyncIfTimingRef2AlarmClear,
|
|
tmnxEqFlashDataLoss,
|
|
tmnxEqFlashDiskFull,
|
|
tmnxPeSoftwareLoadFailed,
|
|
tmnxPeBootloaderVersionMismatch,
|
|
tmnxPeBootromVersionMismatch,
|
|
tmnxPeFPGAVersionMismatch,
|
|
tmnxEqSyncIfTimingBITSAlarm,
|
|
tmnxEqSyncIfTimingBITSAlarmClear,
|
|
tmnxEqCardFirmwareUpgraded,
|
|
tmnxEqMdaCfgNotCompatible
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of notifications supporting the management of chassis
|
|
hardware for release 3.0 on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 20 }
|
|
|
|
tmnxChassisNotificationV6v0Group NOTIFICATION-GROUP
|
|
NOTIFICATIONS { tmnxEnvTempTooHigh,
|
|
tmnxEqPowerSupplyFailure,
|
|
tmnxEqPowerSupplyInserted,
|
|
tmnxEqPowerSupplyRemoved,
|
|
tmnxEqFanFailure,
|
|
tmnxEqCardFailure,
|
|
tmnxEqCardInserted,
|
|
tmnxEqCardRemoved,
|
|
tmnxEqWrongCard,
|
|
tmnxPeSoftwareVersionMismatch,
|
|
tmnxRedPrimaryCPMFail,
|
|
tmnxChassisNotificationClear,
|
|
tmnxEqSyncIfTimingHoldover,
|
|
tmnxEqSyncIfTimingHoldoverClear,
|
|
tmnxEqSyncIfTimingRef1Alarm,
|
|
tmnxEqSyncIfTimingRef1AlarmClear,
|
|
tmnxEqSyncIfTimingRef2Alarm,
|
|
tmnxEqSyncIfTimingRef2AlarmClear,
|
|
tmnxEqFlashDataLoss,
|
|
tmnxEqFlashDiskFull,
|
|
tmnxPeSoftwareLoadFailed,
|
|
tmnxPeBootloaderVersionMismatch,
|
|
tmnxPeBootromVersionMismatch,
|
|
tmnxPeFPGAVersionMismatch,
|
|
tmnxEqSyncIfTimingBITSAlarm,
|
|
tmnxEqSyncIfTimingBITSAlarmClear,
|
|
tmnxEqCardFirmwareUpgraded,
|
|
tmnxChassisUpgradeInProgress,
|
|
tmnxChassisUpgradeComplete,
|
|
tmnxChassisHiBwMcastAlarm,
|
|
tmnxEqMdaCfgNotCompatible
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notifications supporting the management of chassis
|
|
hardware for release 6.0 on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 21 }
|
|
|
|
tmnx7710SETSRefSrcHwV6v0Group OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxSyncIfTimingRef1SrcHw,
|
|
tmnxSyncIfTimingRef1BITSIfType,
|
|
tmnxSyncIfTimingRef2SrcHw,
|
|
tmnxSyncIfTimingRef2BITSIfType,
|
|
tSyncIfTimingAdmRef1SrcHw,
|
|
tSyncIfTimingAdmRef1BITSIfType,
|
|
tSyncIfTimingAdmRef2SrcHw,
|
|
tSyncIfTimingAdmRef2BITSIfType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of 'Synchronous Equipment
|
|
Timing' (SETS) when the references are of type 'Building Integrated
|
|
Timing Supply' (BITS) for release 6.0 on Alcatel 7710 SR series
|
|
systems."
|
|
::= { tmnxChassisGroups 22 }
|
|
|
|
tmnxMDAMcPathMgmtV6v0Group OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxMDAMcPathMgmtBwPlcyName,
|
|
tmnxMDAMcPathMgmtPriPathLimit,
|
|
tmnxMDAMcPathMgmtSecPathLimit,
|
|
tmnxMDAMcPathMgmtAncPathLimit,
|
|
tmnxMDAMcPathMgmtAdminState,
|
|
tmnxMDAMcPathMgmtPriInUseBw,
|
|
tmnxMDAMcPathMgmtSecInUseBw,
|
|
tmnxMDAMcPathMgmtAncInUseBw,
|
|
tmnxMDAMcPathMgmtBlkHoleInUseBw
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of Multicast Path
|
|
Management feature for release 6.0 on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 24 }
|
|
|
|
tmnxCardV6v0NamedPoolPlcyGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxCardNamedPoolAdminMode,
|
|
tmnxCardNamedPoolOperMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting named buffer pools for release
|
|
6.0 on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 25 }
|
|
|
|
tmnxChassisNotifyObjsV6v0Group OBJECT-GROUP
|
|
OBJECTS { tmnxChassisNotifyCardName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects added in 6.0 release to support chassis
|
|
hardware notifications on Alcatel 7x50 SR series systems."
|
|
::= { tmnxChassisGroups 26 }
|
|
|
|