S5-CHASSIS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY,
|
|
Integer32, Counter32, Gauge32,
|
|
TimeTicks, IpAddress
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TruthValue
|
|
FROM SNMPv2-TC
|
|
s5Chassis
|
|
FROM S5-ROOT-MIB
|
|
AttId, LocChan
|
|
FROM S5-TCS-MIB
|
|
Ipv6Address, Ipv6AddressPrefix
|
|
FROM IPV6-TC
|
|
InterfaceIndex
|
|
FROM IF-MIB;
|
|
|
|
s5ChasMib MODULE-IDENTITY
|
|
LAST-UPDATED "201504070000Z"
|
|
ORGANIZATION "Avaya"
|
|
CONTACT-INFO "Avaya"
|
|
DESCRIPTION
|
|
"5000 Chassis MIB
|
|
|
|
Copyright 1995-2012 Nortel Networks, Inc.
|
|
All rights reserved.
|
|
This Nortel Networks SNMP Management Information Base Specification
|
|
(Specification) embodies Nortel Networks' confidential and
|
|
proprietary intellectual property. Nortel Networks retains all
|
|
title and ownership in the Specification, including any
|
|
revisions.
|
|
|
|
This Specification is supplied 'AS IS', and Nortel Networks makes
|
|
no warranty, either express or implied, as to the use,
|
|
operation, condition, or performance of the Specification."
|
|
|
|
REVISION "201504070000Z" -- April 7, 2015
|
|
DESCRIPTION "Version 155: Changed s5ChasComDescr size."
|
|
|
|
REVISION "201311260000Z" -- November 26, 2013
|
|
DESCRIPTION "Version 154: Added s5ChasComUpTime object in s5ChasComTable."
|
|
|
|
REVISION "201310180000Z" -- October 18, 2013
|
|
DESCRIPTION "Version 153: Added s5ChasComIpMgmtShutdown."
|
|
|
|
REVISION "201310160000Z" -- October 16, 2013
|
|
DESCRIPTION "Version 152: Added s5ChasPluggables,
|
|
s5ChasGbicInfoTable."
|
|
|
|
REVISION "201310100000Z" -- October 10, 2013
|
|
DESCRIPTION "Version 151: Corrected MIB definitions."
|
|
|
|
REVISION "201309090000Z" -- September 9, 2013
|
|
DESCRIPTION "Version 150: Added s5ChasComIpMgmtLimit,
|
|
s5ChasComIpMgmtTimeout."
|
|
|
|
REVISION "201308270000Z" -- August 27, 2013
|
|
DESCRIPTION "Version 149: Added s5ChasBrdFanLeds."
|
|
|
|
REVISION "201212200000Z" -- December 20, 2012
|
|
DESCRIPTION "Version 148: Added s5ChasStoreDescription,
|
|
s5ChasStoreAge."
|
|
|
|
REVISION "201206010000Z" -- June 1, 2012
|
|
DESCRIPTION "Version 147: Added s5ChasComIpv6MgmtAddress,
|
|
s5ChasComIpv6MgmtNetMask."
|
|
|
|
REVISION "201202210000Z" -- Feb 21, 2012
|
|
DESCRIPTION "Version 146: Added s5ChasComIpMgmtAddress,
|
|
s5ChasComIpMgmtNetMask,
|
|
s5ChasComIpMgmtGateway."
|
|
|
|
REVISION "201110110000Z" -- Oct 11, 2011
|
|
DESCRIPTION "Version 145: Added s5ChasComIpv6Address, s5ChasComIpv6NetMask."
|
|
|
|
REVISION "201104220000Z" -- Apr 22, 2011
|
|
DESCRIPTION "Version 144: Added s5ChasNotify."
|
|
|
|
REVISION "201010180000Z" -- Oct 18, 2010
|
|
DESCRIPTION "Version 143: Added s5ChasStoreUsedSize."
|
|
|
|
REVISION "200805220000Z" -- May 22, 2008
|
|
DESCRIPTION "Version 142: Added s5ChasComRunningSoftwareVer."
|
|
|
|
REVISION "200802200000Z" -- Feb 20, 2008
|
|
DESCRIPTION "Version 141: Added objects for memory utilization in MegaBytes."
|
|
|
|
REVISION "200505110000Z" -- May 11, 2005
|
|
DESCRIPTION "Version 140: Fix support for USB flash dongles."
|
|
|
|
REVISION "200505050000Z" -- May 5, 2005
|
|
DESCRIPTION "Version 139: Fleshed out support for USB flash dongles."
|
|
|
|
REVISION "200410290000Z" -- October 29, 2004
|
|
DESCRIPTION "Version 138: Added baystack15 rpsu type."
|
|
|
|
REVISION "200407200000Z" -- July 20, 2004
|
|
DESCRIPTION "Version 137: Added version info."
|
|
|
|
::= { s5Chassis 10 }
|
|
|
|
|
|
-- Chassis Groups
|
|
|
|
|
|
s5ChasGen OBJECT IDENTIFIER ::= { s5Chassis 1 }
|
|
s5ChasGrp OBJECT IDENTIFIER ::= { s5Chassis 2 }
|
|
s5ChasCom OBJECT IDENTIFIER ::= { s5Chassis 3 }
|
|
s5ChasBrd OBJECT IDENTIFIER ::= { s5Chassis 4 }
|
|
s5ChasStore OBJECT IDENTIFIER ::= { s5Chassis 5 }
|
|
s5ChasSm OBJECT IDENTIFIER ::= { s5Chassis 6 }
|
|
s5ChasTmpSnr OBJECT IDENTIFIER ::= { s5Chassis 7 }
|
|
s5ChasUtil OBJECT IDENTIFIER ::= { s5Chassis 8 }
|
|
s5ChasPs OBJECT IDENTIFIER ::= { s5Chassis 9 }
|
|
s5ChasNotify OBJECT IDENTIFIER ::= { s5Chassis 11 }
|
|
s5ChasPluggables OBJECT IDENTIFIER ::= { s5Chassis 12 }
|
|
|
|
-- SECTION 2: MIB Objects
|
|
|
|
|
|
-- General Chassis Information
|
|
|
|
|
|
s5ChasType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis type. This is 'what kind of
|
|
box' is being managed. The values are
|
|
defined under s5ChasTypeVal in the
|
|
Registration MIB."
|
|
::= { s5ChasGen 1 }
|
|
|
|
s5ChasDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the chassis.
|
|
The value is a zero length string
|
|
if no information is available."
|
|
::= { s5ChasGen 2 }
|
|
|
|
s5ChasLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical location of the chassis
|
|
(e.g., 'fourth floor wiring closet in
|
|
building A'). The value is a zero
|
|
length string if no information
|
|
is available. Note: this object is
|
|
different from sysLocation in MIB-II.
|
|
However, an agent may use this value for
|
|
sysLocation if none is configured in the
|
|
the agent."
|
|
::= { s5ChasGen 3 }
|
|
|
|
s5ChasContact OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The textual identification of the
|
|
contact person for the chassis, together
|
|
with information on how to contact
|
|
this person. The value is a zero length
|
|
string if no information is available.
|
|
Note: this object is different from sysContact
|
|
in MIB-II. However, an agent may use this value
|
|
for sysContact if none is configured in the
|
|
agent."
|
|
::= { s5ChasGen 4 }
|
|
|
|
s5ChasVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the chassis in the form
|
|
'major.minor.maintenance[letters]'. If the
|
|
version is unknown or not available then
|
|
the value should be a zero length string."
|
|
::= { s5ChasGen 5 }
|
|
|
|
s5ChasSerNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of the chassis. If the
|
|
serial number is unknown or unavailable then
|
|
the value should be a zero length string."
|
|
::= { s5ChasGen 6 }
|
|
|
|
s5ChasGblPhysChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of physical changes (i.e.,
|
|
an addition or removal of a component or
|
|
sub-component) that have been detected in the
|
|
chassis since cold/warm start of the agent."
|
|
::= { s5ChasGen 7 }
|
|
|
|
s5ChasGblPhysLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last
|
|
physical change (i.e., addition or
|
|
removal of a module or sub-module) was
|
|
detected in the chassis. If none have
|
|
been detected since cold/warm start of
|
|
the agent, then the value is zero."
|
|
::= { s5ChasGen 8 }
|
|
|
|
s5ChasGblAttChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of attachment changes
|
|
across all boards in the chassis that have
|
|
been detected since cold/warm start of
|
|
the agent."
|
|
::= { s5ChasGen 9 }
|
|
|
|
s5ChasGblAttLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last
|
|
attachment change on any board in the chassis
|
|
was detected. If none have been detected
|
|
since cold/warm start of the agent, then the
|
|
value is zero."
|
|
::= { s5ChasGen 10 }
|
|
|
|
s5ChasGblConfChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of configuration changes
|
|
(other than attachment changes, or physical
|
|
additions or removals) across all boards in
|
|
the chassis that have been detected since
|
|
cold/warm start of the agent."
|
|
::= { s5ChasGen 11 }
|
|
|
|
s5ChasGblConfLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last
|
|
configuration change (other than attachment
|
|
changes, or physical additions or removals)
|
|
on any board in the chassis was detected.
|
|
If none have been detected since cold/warm
|
|
start of the agent, then the value is zero."
|
|
::= { s5ChasGen 12 }
|
|
|
|
-- Chassis Group Table
|
|
|
|
|
|
s5ChasGrpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about
|
|
each group that can contain chassis
|
|
components."
|
|
::= { s5ChasGrp 1 }
|
|
|
|
s5ChasGrpEntry OBJECT-TYPE
|
|
SYNTAX S5ChasGrpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the group table.
|
|
Rows can not be created or deleted via
|
|
SNMP requests. The number of entries
|
|
is determined by the physical construction
|
|
of the chassis."
|
|
INDEX { s5ChasGrpIndx }
|
|
::= { s5ChasGrpTable 1 }
|
|
|
|
S5ChasGrpEntry ::= SEQUENCE {
|
|
s5ChasGrpIndx Integer32,
|
|
s5ChasGrpType OBJECT IDENTIFIER,
|
|
s5ChasGrpDescr DisplayString,
|
|
s5ChasGrpMaxEnts Integer32,
|
|
s5ChasGrpNumEnts Integer32,
|
|
s5ChasGrpPhysChngs Counter32,
|
|
s5ChasGrpPhysLstChng TimeTicks,
|
|
s5ChasGrpEncodeFactor Integer32
|
|
}
|
|
|
|
s5ChasGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the group."
|
|
::= { s5ChasGrpEntry 1 }
|
|
|
|
s5ChasGrpType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the group. The group type
|
|
determines the types of items that can
|
|
be plugged into the positions in the
|
|
group. The groups are defined under
|
|
s5ChasGrpTypeVal in the Registration MIB."
|
|
::= { s5ChasGrpEntry 2 }
|
|
|
|
s5ChasGrpDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of the group. If not
|
|
available, the value is a zero length
|
|
string."
|
|
::= { s5ChasGrpEntry 3 }
|
|
|
|
s5ChasGrpMaxEnts OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of entries
|
|
in the group. If not available, a
|
|
value of -1 is returned."
|
|
::= { s5ChasGrpEntry 4 }
|
|
|
|
s5ChasGrpNumEnts OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current number of entries
|
|
in the group. If not available,
|
|
a value of -1 is returned."
|
|
::= { s5ChasGrpEntry 5 }
|
|
|
|
s5ChasGrpPhysChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of physical changes (i.e.,
|
|
an addition or removal of a component or
|
|
sub-component) that have been detected in
|
|
the group since cold/warm start of the agent."
|
|
::= { s5ChasGrpEntry 6 }
|
|
|
|
s5ChasGrpPhysLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime that the last
|
|
physical change (i.e., addition or
|
|
removal of a module or sub-module) was
|
|
detected in the group. If none have been
|
|
detected since cold/warm start of the
|
|
agent, then the value is zero."
|
|
::= { s5ChasGrpEntry 7 }
|
|
|
|
s5ChasGrpEncodeFactor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The multiplication factor used in encoding
|
|
the component index of a component in the group.
|
|
The component index for any group should be
|
|
determined in conjunction with this object for
|
|
that group. A value of 1 indicates 'no encoding'.
|
|
|
|
Stackable platforms:
|
|
The component index is encoded using the
|
|
following formula:
|
|
Component Index =
|
|
(Unit# * s5ChasGrpEncodeFactor) + Module#
|
|
|
|
Where: Unit# is obtained from s5ChasComIndx
|
|
for the Unit Group, and Module# is the
|
|
module number in a unit starting from 1
|
|
and increases in a left-to-right and
|
|
bottom-to-top fashion.
|
|
|
|
NonStackable platforms:
|
|
These NMMs like 5310, 5510 will always return a
|
|
value of 1 for this object. Encoding/decoding
|
|
should not be performed in this case."
|
|
::= { s5ChasGrpEntry 8 }
|
|
|
|
-- Component (and sub-component) Table
|
|
|
|
|
|
s5ChasComTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasComEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information
|
|
about each chassis level component
|
|
and sub-component."
|
|
::= { s5ChasCom 1 }
|
|
|
|
s5ChasComEntry OBJECT-TYPE
|
|
SYNTAX S5ChasComEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the component/sub-component
|
|
table. Rows can not be created or
|
|
deleted via SNMP requests. Entries are
|
|
created and deleted when components or
|
|
sub-components are inserted or removed
|
|
from the chassis."
|
|
INDEX { s5ChasComGrpIndx,
|
|
s5ChasComIndx,
|
|
s5ChasComSubIndx }
|
|
::= { s5ChasComTable 1 }
|
|
|
|
S5ChasComEntry ::= SEQUENCE {
|
|
s5ChasComGrpIndx Integer32,
|
|
s5ChasComIndx Integer32,
|
|
s5ChasComSubIndx Integer32,
|
|
|
|
s5ChasComType OBJECT IDENTIFIER,
|
|
s5ChasComDescr DisplayString,
|
|
s5ChasComVer DisplayString,
|
|
s5ChasComSerNum DisplayString,
|
|
s5ChasComLstChng TimeTicks,
|
|
|
|
s5ChasComAdminState INTEGER,
|
|
s5ChasComOperState INTEGER,
|
|
|
|
s5ChasComMaxSubs Integer32,
|
|
s5ChasComNumSubs Integer32,
|
|
|
|
s5ChasComRelPos Integer32,
|
|
s5ChasComLocation DisplayString,
|
|
s5ChasComGroupMap Integer32,
|
|
|
|
s5ChasComBaseNumPorts Integer32,
|
|
s5ChasComTotalNumPorts Integer32,
|
|
|
|
s5ChasComIpAddress IpAddress,
|
|
|
|
s5ChasComRunningSoftwareVer DisplayString,
|
|
s5ChasComIpv6Address Ipv6Address,
|
|
s5ChasComIpv6NetMask Ipv6AddressPrefix,
|
|
|
|
s5ChasComIpMgmtAddress IpAddress,
|
|
s5ChasComIpMgmtNetMask IpAddress,
|
|
s5ChasComIpMgmtGateway IpAddress,
|
|
|
|
s5ChasComIpv6MgmtAddress Ipv6Address,
|
|
s5ChasComIpv6MgmtNetMask Ipv6AddressPrefix,
|
|
|
|
s5ChasComIpMgmtLimit Integer32,
|
|
s5ChasComIpMgmtTimeout Integer32,
|
|
s5ChasComIpMgmtShutdown TruthValue,
|
|
|
|
s5ChasComUpTime TimeTicks
|
|
}
|
|
|
|
s5ChasComGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the chassis level group which
|
|
contains this component."
|
|
::= { s5ChasComEntry 1 }
|
|
|
|
s5ChasComIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the component in the group.
|
|
For example, for modules in the 'board'
|
|
group, this is the slot number."
|
|
::= { s5ChasComEntry 2 }
|
|
|
|
s5ChasComSubIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this table entry (i.e. table row)
|
|
describes a component, then the value is
|
|
zero. Otherwise, this table entry describes
|
|
a sub-component and this is the index of
|
|
the sub-component."
|
|
::= { s5ChasComEntry 3 }
|
|
|
|
s5ChasComType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of component/sub-component. The
|
|
values are defined under s5ChasComTypeVal
|
|
in the Registration MIB."
|
|
::= { s5ChasComEntry 4 }
|
|
|
|
s5ChasComDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the component/sub-component.
|
|
If not available, the value is a zero length
|
|
string."
|
|
::= { s5ChasComEntry 5 }
|
|
|
|
s5ChasComVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number of the component/sub-component.
|
|
If not available, the value is a zero length
|
|
string."
|
|
::= { s5ChasComEntry 6 }
|
|
|
|
s5ChasComSerNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of the component/sub-component.
|
|
If not available, the value is a zero length
|
|
string."
|
|
::= { s5ChasComEntry 7 }
|
|
|
|
s5ChasComLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when it was
|
|
detected that the component/sub-component
|
|
was added to the chassis. If this has not
|
|
occurred since the cold/warm start of the
|
|
agent, then the value is zero."
|
|
::= { s5ChasComEntry 8 }
|
|
|
|
s5ChasComAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notAvail(2),
|
|
disable(3),
|
|
enable(4),
|
|
reset(5),
|
|
test(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the component/sub-component.
|
|
The values that are read-only are:
|
|
other(1)......currently in some other state
|
|
notAvail(2)...actual value is not available
|
|
|
|
The possible values that can be read and
|
|
written are:
|
|
disable(3)...disable operation
|
|
enable(4)....enable operation
|
|
reset(5).....reset component
|
|
test(6)......start self test of component, with
|
|
the result to be normal(5),
|
|
warning(8), nonFatalErr(9),
|
|
or fatalErr(10) in object
|
|
s5ChasComOperState
|
|
The allowable (and meaningful) values
|
|
are determined by the component type."
|
|
::= { s5ChasComEntry 9 }
|
|
|
|
s5ChasComOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notAvail(2),
|
|
removed(3),
|
|
disabled(4),
|
|
normal(5),
|
|
resetInProg(6),
|
|
testing(7),
|
|
warning(8),
|
|
nonFatalErr(9),
|
|
fatalErr(10),
|
|
notConfig(11),
|
|
obsoleted(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the
|
|
component. The possible values are:
|
|
other(1).........some other state
|
|
notAvail(2)......state not available
|
|
removed(3).......component removed
|
|
disabled(4)......operation disabled
|
|
normal(5)........normal operation
|
|
resetInProg(6)...reset in progress
|
|
testing(7).......doing a self test
|
|
warning(8).......operating at warning level
|
|
nonFatalErr(9)...operating at error level
|
|
fatalErr(10).....error stopped operation
|
|
notConfig(11)....module needs to be configured
|
|
obsoleted(12)...module is obsoleted but in the chassis
|
|
The allowable (and meaningful) values
|
|
are determined by the component type."
|
|
::= { s5ChasComEntry 10 }
|
|
|
|
s5ChasComMaxSubs OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The potential number of sub-components
|
|
that can be attached to the component.
|
|
A value of zero means none. A value of -1
|
|
indicates that no component information is
|
|
available. The actual number of
|
|
installed sub-components is found in
|
|
s5ChasComNumSubs.
|
|
If this entry is a sub-component, then
|
|
this object has a value of zero."
|
|
::= { s5ChasComEntry 11 }
|
|
|
|
s5ChasComNumSubs OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual number of sub-components that
|
|
are attached to the component. A value of
|
|
zero means none. A value of -1 indicates
|
|
that no component information is available.
|
|
The potential number of sub-components
|
|
that can be installed is found in
|
|
s5ChasComMaxSubs.
|
|
If this entry is a sub-component, then
|
|
this object has the value of zero."
|
|
::= { s5ChasComEntry 12 }
|
|
|
|
s5ChasComRelPos OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object describes the position of
|
|
each component in the unit group relative
|
|
to each other. Components in the unit group
|
|
are numbered in the ascending order with the
|
|
uppermost component being numbered one. The
|
|
value of this object should never be greater
|
|
than the value of s5ChasGrpMaxEnts. If not
|
|
available, a value of zero will be returned.
|
|
|
|
Note: This object is only implemented in
|
|
agents that support 'virtual' chassis."
|
|
::= { s5ChasComEntry 13 }
|
|
|
|
s5ChasComLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object provides geographic location
|
|
information of a component in a system
|
|
modeled as a chassis, but possibly physically
|
|
implemented with geographically separate devices
|
|
connected together to exchange managment information.
|
|
Chassis' modeled in this manner are sometimes refered
|
|
to as 'virtual chassis'. An example value is:
|
|
'4th flr wiring closet in blg A'.
|
|
|
|
Notes: 1.) This object is applicable only to
|
|
components that can be found in either
|
|
the Board or Unit groups. If the
|
|
information is unavailable (i.e., not
|
|
modeling a virtual chassis or component
|
|
is not in Board or Unit group), the value
|
|
is a zero length string.
|
|
2.) If this object is applicable and is not
|
|
assigned a value via a SNMP SET PDU when
|
|
the row is created, the value will default
|
|
to the value of the object s5ChasComSerNum."
|
|
::= { s5ChasComEntry 14 }
|
|
|
|
s5ChasComGroupMap OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object describes the group mapping of
|
|
each component in the chassis. For the
|
|
components in the unit group, the value of this
|
|
object should be the backplane number to which the
|
|
unit is connected. The value of this object should
|
|
never be greater than the value of s5ChasGrpMaxEnts.
|
|
If not available, a value of zero should be returned."
|
|
::= { s5ChasComEntry 15 }
|
|
|
|
s5ChasComBaseNumPorts OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of ports (of any type)
|
|
contained in a component, not including any sub-components
|
|
contained within the component."
|
|
::= { s5ChasComEntry 16 }
|
|
|
|
s5ChasComTotalNumPorts OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the total number of ports (of
|
|
any type) contained in a component, including any ports
|
|
contained in sub-components contained within the component."
|
|
::= { s5ChasComEntry 17 }
|
|
|
|
s5ChasComIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of a component. For components that do not
|
|
have an IP address/stack, this value should always be 0.0.0.0.
|
|
Note that for a stackable system in stack mode, this will be
|
|
the standalone IP address for individual units in the stack."
|
|
::= { s5ChasComEntry 18 }
|
|
|
|
s5ChasComRunningSoftwareVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version number of the software image running on this
|
|
component/sub-component.
|
|
If not available, the value is a zero length
|
|
string."
|
|
::= { s5ChasComEntry 19 }
|
|
|
|
s5ChasComIpv6Address OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of a component. For components that do not
|
|
have an IPv6 address/stack, this value should always be 0::0.
|
|
Note that for a stackable system in stack mode, this will be
|
|
the standalone IPv6 address for individual units in the stack."
|
|
::= { s5ChasComEntry 20 }
|
|
|
|
s5ChasComIpv6NetMask OBJECT-TYPE
|
|
SYNTAX Ipv6AddressPrefix
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 netmask of a component. For components that do not
|
|
have an IPv6 address/stack, this value should always be 0::0.
|
|
Note that for a stackable system in stack mode, this will be
|
|
the standalone IPv6 netmask for individual units in the stack."
|
|
::= { s5ChasComEntry 21 }
|
|
|
|
s5ChasComIpMgmtAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address associated with the physical dedicated
|
|
management port (out of band management port) of a component. For
|
|
components that do not have an IP address/stack associated with the
|
|
dedicated management port, this value should always be 0.0.0.0.
|
|
Note that for a stackable system in stack mode, this IP address
|
|
always applies to individual units in the stack."
|
|
::= { s5ChasComEntry 22 }
|
|
|
|
s5ChasComIpMgmtNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP netmask associated with the physical dedicated
|
|
management port (out of band management port) of a component. For
|
|
components that do not have an IP address/stack associated with the
|
|
dedicated management port, this value should always be 0.0.0.0.
|
|
Note that for a stackable system in stack mode, this netmask
|
|
always applies to individual units in the stack."
|
|
::= { s5ChasComEntry 23 }
|
|
|
|
s5ChasComIpMgmtGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the default gateway associated with the
|
|
physical dedicated management port (out of band management port)
|
|
of a component. For components that do not have an IP address/stack
|
|
associated with the dedicated management port, this value should
|
|
always be 0.0.0.0.
|
|
Note that for a stackable system in stack mode, this IP address
|
|
always applies to individual units in the stack."
|
|
::= { s5ChasComEntry 24 }
|
|
|
|
s5ChasComIpv6MgmtAddress OBJECT-TYPE
|
|
SYNTAX Ipv6Address
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address associated with the physical dedicated
|
|
management port (out of band management port) of a component.
|
|
Note that for a stackable system in stack mode, this IP address
|
|
always applies to individual units in the stack."
|
|
::= { s5ChasComEntry 25 }
|
|
|
|
s5ChasComIpv6MgmtNetMask OBJECT-TYPE
|
|
SYNTAX Ipv6AddressPrefix
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 netmask associated with the physical dedicated
|
|
management port (out of band management port) of a component.
|
|
Note that for a stackable system in stack mode, this netmask
|
|
always applies to individual units in the stack."
|
|
::= { s5ChasComEntry 26 }
|
|
|
|
s5ChasComIpMgmtLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (50..10000)
|
|
UNITS "packets per second"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the in-bound packet threshold rate
|
|
for the management port (out of band management port)."
|
|
DEFVAL { 7000 }
|
|
::= { s5ChasComEntry 27 }
|
|
|
|
s5ChasComIpMgmtTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..180)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port shutdown period
|
|
for the management port (out of band management port)."
|
|
DEFVAL { 180 }
|
|
::= { s5ChasComEntry 28 }
|
|
|
|
s5ChasComIpMgmtShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to control whether the out of band management
|
|
port is up or down (false for port up and true for port down)."
|
|
DEFVAL { false }
|
|
::= { s5ChasComEntry 29 }
|
|
|
|
s5ChasComUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in hundredths of a second)
|
|
since the unit was initialized."
|
|
::= { s5ChasComEntry 30 }
|
|
|
|
-- Board Table
|
|
|
|
s5ChasBrdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasBrdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about each
|
|
board that can be inserted into a slot.
|
|
These include boards such as Repeater Modules
|
|
and Network Management Modules."
|
|
::= { s5ChasBrd 1 }
|
|
|
|
s5ChasBrdEntry OBJECT-TYPE
|
|
SYNTAX S5ChasBrdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the board table. Entries can not
|
|
be created or deleted via SNMP. Entries are
|
|
created and deleted when boards are inserted
|
|
or removed from slots in the chassis."
|
|
INDEX { s5ChasBrdIndx }
|
|
::= { s5ChasBrdTable 1 }
|
|
|
|
S5ChasBrdEntry ::= SEQUENCE {
|
|
s5ChasBrdIndx Integer32,
|
|
s5ChasBrdLeds OCTET STRING,
|
|
s5ChasBrdNumAtt Integer32,
|
|
s5ChasBrdAttChngs Counter32,
|
|
s5ChasBrdAttLstChng TimeTicks,
|
|
s5ChasBrdStatusDsply DisplayString,
|
|
s5ChasBrdDateCode DisplayString,
|
|
s5ChasBrdCfgSrc INTEGER,
|
|
s5ChasBrdCfgChngs Counter32,
|
|
s5ChasBrdFanLeds OCTET STRING
|
|
}
|
|
|
|
s5ChasBrdIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the board. This corresponds to
|
|
the index of the slot containing the board."
|
|
::= { s5ChasBrdEntry 1 }
|
|
|
|
s5ChasBrdLeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit array that contains the value of the
|
|
front panel LEDs and the annunciator. This is
|
|
a packed bit string; each LED is encoded into
|
|
4 bits (a nibble). The first nibble is stored
|
|
in the high order bits of the first octet. The
|
|
second nibble is stored in the low order bits
|
|
the first octet, etc. However, the current
|
|
mapping is that the first three nibbles are
|
|
reserved, the fourth nibble has the value of
|
|
the 'annunciator', and the 'normal' LEDs start
|
|
with the fifth nibble. If the LED values are not
|
|
available, a zero length string is returned. The
|
|
following shows the meaning of each bit (bit 0 is
|
|
the least significant bit) when it has a value
|
|
of one:
|
|
|
|
bit meaning
|
|
--- -------
|
|
0 green light
|
|
1 yellow light
|
|
2 blinking
|
|
3 reserved"
|
|
::= { s5ChasBrdEntry 2 }
|
|
|
|
s5ChasBrdNumAtt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of backplane network
|
|
attachment points on the board.
|
|
This may vary based on the mode of the
|
|
board for FDDI."
|
|
::= { s5ChasBrdEntry 3 }
|
|
|
|
s5ChasBrdAttChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of attachment changes
|
|
for the board that have been detected since
|
|
cold/warm start of the agent or since
|
|
the board was inserted."
|
|
::= { s5ChasBrdEntry 4 }
|
|
|
|
s5ChasBrdAttLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last
|
|
attachment change on the board
|
|
has detected. If none have been detected
|
|
since cold/warm start of the agent, then
|
|
the value is zero."
|
|
::= { s5ChasBrdEntry 5 }
|
|
|
|
s5ChasBrdStatusDsply OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..48))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current ASCII character display of
|
|
the board. The length returned should
|
|
match the length of the display.
|
|
Boards with multiple displays should
|
|
return the values concatenated together.
|
|
Boards with no display hardware should
|
|
return a zero length string."
|
|
::= { s5ChasBrdEntry 6 }
|
|
|
|
s5ChasBrdDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date of manufacture of the board
|
|
in ASCII in the format: YYYYmmdd. For
|
|
example, the value for April 13, 1993
|
|
is 19930413. If not available, the
|
|
value is a zero-length string."
|
|
::= { s5ChasBrdEntry 7 }
|
|
|
|
s5ChasBrdCfgSrc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
dfltJmpr(2),
|
|
prmMem(3),
|
|
brdCfg(4),
|
|
sm(5),
|
|
smDfltJmpr(6),
|
|
smPrmMem(7),
|
|
smBrdCfg(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of the configuration
|
|
at the last board reset. The values
|
|
are:
|
|
other(1)........unknown or some other value
|
|
dfltJmpr(2).....default jumpers
|
|
prmMem(3).......permanent memory on board
|
|
brdCfg(4).......saved configuration on board
|
|
sm(5)...........supervisor
|
|
smDfltJmpr(6)...SM and default jumpers
|
|
smPrmMem(7).....SM and permanent memory on board
|
|
smBrdCfg(8).....SM and saved configuration on board"
|
|
::= { s5ChasBrdEntry 8 }
|
|
|
|
s5ChasBrdCfgChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of configuration
|
|
changes for the board that have been
|
|
detected since cold/warm start of the
|
|
agent or since the board was inserted."
|
|
::= { s5ChasBrdEntry 9 }
|
|
|
|
s5ChasBrdFanLeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit array that contains the value of the
|
|
front panel LEDs of the fan trays. This is
|
|
a packed bit string; each LED is encoded into
|
|
4 bits (a nibble). The first nibble is stored
|
|
in the high order bits of the first octet. The
|
|
second nibble is stored in the low order bits
|
|
of the first octet etc. The current mapping is
|
|
that the first four nibbles are reserved,
|
|
the fifth nibble has the value of the
|
|
'annunciator', and the 'normal' LEDs start with
|
|
the sixth nibble. If the LED values are not
|
|
available, a zero length string is returned. The
|
|
following shows the meaning of each bit (bit 0 is
|
|
the least significant bit) when it has a value
|
|
of one:
|
|
|
|
bit meaning
|
|
--- -------
|
|
0 red light
|
|
1 blue light
|
|
2 purple light
|
|
3 blinking
|
|
4 reserved"
|
|
::= { s5ChasBrdEntry 10 }
|
|
|
|
|
|
-- Attachment Point Table
|
|
|
|
|
|
s5ChasAttTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasAttEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about each
|
|
backplane attachment point on a board.
|
|
The number of entries for a board is the
|
|
value of s5ChasBrdNumAtt."
|
|
::= { s5ChasBrd 2 }
|
|
|
|
s5ChasAttEntry OBJECT-TYPE
|
|
SYNTAX S5ChasAttEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the attachment point table.
|
|
Entries can not be created or deleted
|
|
via SNMP. Entries are created and deleted
|
|
when boards are inserted or removed from
|
|
slots in the chassis, or the number of
|
|
attachment points is changed."
|
|
INDEX { s5ChasAttBrdIndx,
|
|
s5ChasAttIndx }
|
|
::= { s5ChasAttTable 1 }
|
|
|
|
S5ChasAttEntry ::= SEQUENCE {
|
|
s5ChasAttBrdIndx Integer32,
|
|
s5ChasAttIndx Integer32,
|
|
s5ChasAttDfltAtt AttId,
|
|
s5ChasAttCurAtt AttId,
|
|
s5ChasAttChngs Counter32,
|
|
s5ChasAttLstChng TimeTicks,
|
|
s5ChasAttClusterConnCapability OCTET STRING
|
|
}
|
|
|
|
s5ChasAttBrdIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the board. This corresponds to
|
|
the index of the slot containing the board."
|
|
::= { s5ChasAttEntry 1 }
|
|
|
|
s5ChasAttIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the attachment point on
|
|
the board."
|
|
::= { s5ChasAttEntry 2 }
|
|
|
|
s5ChasAttDfltAtt OBJECT-TYPE
|
|
SYNTAX AttId
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default setting for the attachment
|
|
point. An attachment point may be attached
|
|
to a local channel, not attached to any
|
|
backplane network, or attached to a media
|
|
specific backplane network. (The valid choices
|
|
depend on each specific attachment point.)
|
|
NOTE: This value will always be valid
|
|
and may change when the backplane divider
|
|
switch setting is changed."
|
|
::= { s5ChasAttEntry 3 }
|
|
|
|
s5ChasAttCurAtt OBJECT-TYPE
|
|
SYNTAX AttId
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current setting for the attachment
|
|
point. The slot position of the board,
|
|
the setting of the backplane divider switch(es),
|
|
and the mode setting affect which backplane
|
|
networks are valid values. Also, some boards
|
|
may put limitations on which backplane
|
|
network(s) or local channel(s) may be used."
|
|
::= { s5ChasAttEntry 4 }
|
|
|
|
s5ChasAttChngs OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of attachment changes
|
|
for the attachment point that have been
|
|
detected since cold/warm start of the agent."
|
|
::= { s5ChasAttEntry 5 }
|
|
|
|
s5ChasAttLstChng OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last
|
|
attachment change for the attachment
|
|
point was detected. If none have been
|
|
detected since cold/warm start of the
|
|
agent, then the value is zero."
|
|
::= { s5ChasAttEntry 6 }
|
|
|
|
s5ChasAttClusterConnCapability OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit array that contains the bit map
|
|
representing all available backplane
|
|
segment and local segment connections for
|
|
the cluster. One bit is also reserved to
|
|
indicate if the cluster has an isolate
|
|
capability.
|
|
|
|
The first 31 bits of the array represent
|
|
the backplane numbers, starting from the
|
|
lower order bit. Bit 32 indicates whether
|
|
the Cluster has a null connection capability.
|
|
The bits in the fifth and sixth octets,
|
|
starting with bits in the lower order octet,
|
|
represent local segments that the cluster
|
|
can connect to.
|
|
|
|
A bit with a value of 1 means that the
|
|
cluster is capable of connecting to the
|
|
corresponding backplane segment, local segment
|
|
or null segment."
|
|
::= { s5ChasAttEntry 7 }
|
|
|
|
-- Local Channel Table
|
|
|
|
|
|
s5ChasLocChanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasLocChanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about each
|
|
'dual mode' local channel on a board."
|
|
::= { s5ChasBrd 3 }
|
|
|
|
s5ChasLocChanEntry OBJECT-TYPE
|
|
SYNTAX S5ChasLocChanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the local channel table.
|
|
Entries can not be created or deleted
|
|
via SNMP. Entries are added or removed
|
|
by adding or removing a board that has
|
|
a 'dual mode' local channel from a slot
|
|
in the chassis."
|
|
INDEX { s5ChasLocChanBrdIndx,
|
|
s5ChasLocChanIndx }
|
|
::= { s5ChasLocChanTable 1 }
|
|
|
|
S5ChasLocChanEntry ::= SEQUENCE {
|
|
s5ChasLocChanBrdIndx Integer32,
|
|
s5ChasLocChanIndx LocChan,
|
|
s5ChasLocChanBkplMode INTEGER
|
|
}
|
|
|
|
s5ChasLocChanBrdIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the board. This corresponds to
|
|
the index of the slot containing the board."
|
|
::= { s5ChasLocChanEntry 1 }
|
|
|
|
s5ChasLocChanIndx OBJECT-TYPE
|
|
SYNTAX LocChan
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the local channel."
|
|
::= { s5ChasLocChanEntry 2 }
|
|
|
|
s5ChasLocChanBkplMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
connected(2),
|
|
notConnected(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the attachment/isolation
|
|
mode of a local channel to a backplane
|
|
channel. The values that are read/write are:
|
|
connected(2)......connect local chan N to bkpl N
|
|
notConnected(3)...disconnect local chan N from bkpl
|
|
|
|
The possible values that can be read are:
|
|
other(1)..........unknown
|
|
connected(2)......local chan N connected to bkpl N
|
|
notConnected(3)...local chan N isolated from bkpl N"
|
|
::= { s5ChasLocChanEntry 3 }
|
|
|
|
-- Storage Area Table
|
|
|
|
|
|
s5ChasStoreTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasStoreEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table listing the storage areas
|
|
on each component/sub-component in
|
|
the chassis. The number is determined
|
|
by the components in the chassis
|
|
which have manageable storage areas.
|
|
Examples of storage areas include
|
|
RAM(main memory), FLASH, ROM,
|
|
EEPROM, etc. This does not include
|
|
disk drives."
|
|
::= { s5ChasStore 1 }
|
|
|
|
s5ChasStoreEntry OBJECT-TYPE
|
|
SYNTAX S5ChasStoreEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the table of storage areas.
|
|
The entries can not be created or
|
|
deleted via SNMP requests. Only those
|
|
components/sub-components that have
|
|
storage areas that are installed are
|
|
present. Storage areas that are on
|
|
components have a sub-component
|
|
index value of zero. Storage areas that
|
|
are on sub-components have a non-zero
|
|
sub-component index value."
|
|
INDEX { s5ChasStoreGrpIndx,
|
|
s5ChasStoreComIndx,
|
|
s5ChasStoreSubIndx,
|
|
s5ChasStoreIndx }
|
|
::= { s5ChasStoreTable 1 }
|
|
|
|
S5ChasStoreEntry ::= SEQUENCE {
|
|
s5ChasStoreGrpIndx Integer32,
|
|
s5ChasStoreComIndx Integer32,
|
|
s5ChasStoreSubIndx Integer32,
|
|
s5ChasStoreIndx Integer32,
|
|
|
|
s5ChasStoreType OBJECT IDENTIFIER,
|
|
s5ChasStoreCurSize Integer32,
|
|
s5ChasStoreCntntVer DisplayString,
|
|
s5ChasStoreFilename DisplayString,
|
|
s5ChasStoreUsedSize Integer32,
|
|
|
|
s5ChasStoreDescription DisplayString,
|
|
s5ChasStoreAge Integer32
|
|
}
|
|
|
|
s5ChasStoreGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the chassis level group
|
|
which contains the component or
|
|
sub-component containing the storage
|
|
area."
|
|
::= { s5ChasStoreEntry 1 }
|
|
|
|
s5ChasStoreComIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the component or
|
|
the component which contains the
|
|
sub-component containing the
|
|
storage area."
|
|
::= { s5ChasStoreEntry 2 }
|
|
|
|
s5ChasStoreSubIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the storage area is on a component,
|
|
then the value zero. Otherwise, the
|
|
storage area is on a sub-component and
|
|
this is the index of the sub-component."
|
|
::= { s5ChasStoreEntry 3 }
|
|
|
|
s5ChasStoreIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the storage area on the
|
|
component or sub-component."
|
|
::= { s5ChasStoreEntry 4 }
|
|
|
|
s5ChasStoreType OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage area type on the containing
|
|
component/sub-component. The values
|
|
are defined under the .0 branch of the
|
|
value of s5ChasComType for the
|
|
component/sub-component containing the
|
|
storage area in the Registration MIB."
|
|
::= { s5ChasStoreEntry 5 }
|
|
|
|
s5ChasStoreCurSize OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current size of the storage
|
|
area in bytes. A value of zero
|
|
means the storage area is not installed
|
|
or not usable. A value of -1 indicates
|
|
that the size is unknown (or unavailable)."
|
|
::= { s5ChasStoreEntry 6 }
|
|
|
|
s5ChasStoreCntntVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the contents (i.e., the
|
|
code or data) of the storage area in the
|
|
form 'major.minor.maintenance[letters]'.
|
|
If not known or not available, then the value
|
|
is a zero length string. If multiple
|
|
contents are stored in this container, the
|
|
the value will contain multiple sub-versions,
|
|
each separated by a semicolon (;)."
|
|
::= { s5ChasStoreEntry 7 }
|
|
|
|
s5ChasStoreFilename OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the image file to be downloaded or
|
|
uploaded when the s5AgInfoFileAction object
|
|
is set to upload or download an image. When the
|
|
object is not used, the value is a zero-length
|
|
string."
|
|
::= { s5ChasStoreEntry 8 }
|
|
|
|
s5ChasStoreUsedSize OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current size of the storage area that is currently in use,
|
|
measured in bytes. A value of zero means the storage area is
|
|
not in use. A value of -1 means the size is unknown
|
|
(or unavailable)."
|
|
::= { s5ChasStoreEntry 9 }
|
|
|
|
s5ChasStoreDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..128))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string describing the storage area. When the
|
|
object is not used, the value is a zero-length
|
|
string."
|
|
::= { s5ChasStoreEntry 10 }
|
|
|
|
s5ChasStoreAge OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter of the number of writes performed on this storage
|
|
area which for areas residing in flash memory is an
|
|
indication of the flash memory age. This number is the maximum
|
|
number of writes for any of the access units (e.g. sector) from
|
|
the storage area. A value of zero means the storage area is
|
|
not in use. A value of -1 means the age is unknown
|
|
(or unavailable)."
|
|
::= { s5ChasStoreEntry 11 }
|
|
|
|
|
|
-- Supervisor Information
|
|
|
|
|
|
s5ChasSmLeds OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit array that contains the value of the
|
|
supervisor LEDs. (The format of these are the
|
|
same as the format for object s5ChasBrdLeds.)
|
|
If not available, a zero length string is
|
|
returned."
|
|
::= { s5ChasSm 1 }
|
|
|
|
s5ChasSmDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..8))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date of manufacture of the SM module
|
|
in ASCII in the format: YYYYmmdd. For
|
|
example, the value for April 13, 1993
|
|
is 19930413. If not available, a zero
|
|
length string is returned"
|
|
::= { s5ChasSm 2 }
|
|
|
|
-- Temperature Sensor Table
|
|
|
|
|
|
s5ChasTmpSnrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasTmpSnrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains temperature
|
|
sensor values."
|
|
::= { s5ChasTmpSnr 1 }
|
|
|
|
s5ChasTmpSnrEntry OBJECT-TYPE
|
|
SYNTAX S5ChasTmpSnrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the s5ChasTmpSnrTable. Rows
|
|
in this table will exist for each existing
|
|
row in the s5ChasComTable which represents
|
|
a temperature sensor. The values of the
|
|
indices of the row in this table will be
|
|
equal to those of the corresponding row in
|
|
the s5ChasComTable."
|
|
INDEX { s5ChasTmpSnrGrpIndx,
|
|
s5ChasTmpSnrIndx,
|
|
s5ChasTmpSnrSubIndx }
|
|
::= { s5ChasTmpSnrTable 1 }
|
|
|
|
S5ChasTmpSnrEntry ::= SEQUENCE {
|
|
s5ChasTmpSnrGrpIndx Integer32,
|
|
s5ChasTmpSnrIndx Integer32,
|
|
s5ChasTmpSnrSubIndx Integer32,
|
|
s5ChasTmpSnrValue Gauge32,
|
|
s5ChasTmpSnrTmpValue Integer32
|
|
}
|
|
|
|
s5ChasTmpSnrGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the chassis level group which
|
|
contains this component, corresponds to
|
|
s5ChasComGrpIndx."
|
|
::= { s5ChasTmpSnrEntry 1 }
|
|
|
|
s5ChasTmpSnrIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the component in the group.
|
|
Corresponds to s5ChasComIndx."
|
|
::= { s5ChasTmpSnrEntry 2 }
|
|
|
|
s5ChasTmpSnrSubIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-component index. Corresponds to
|
|
s5ChasComSubIndx."
|
|
::= { s5ChasTmpSnrEntry 3 }
|
|
|
|
s5ChasTmpSnrValue OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current temperature value of the temperature
|
|
sensor. This is measured in units of a half degree
|
|
centigrade, e.g. a value of 121 indicates a temperature
|
|
of 60.5 degrees C.
|
|
|
|
This object is deprecated because it cannot represent
|
|
temperature values below 0, as Gauge32 is an unsigned type."
|
|
::= { s5ChasTmpSnrEntry 4 }
|
|
|
|
s5ChasTmpSnrTmpValue OBJECT-TYPE
|
|
SYNTAX Integer32 (-32768..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature value of the temperature
|
|
sensor. This is measured in units of a half degree
|
|
centigrade, e.g. a value of 121 indicates a temperature
|
|
of 60.5 degrees C."
|
|
::= { s5ChasTmpSnrEntry 5 }
|
|
|
|
|
|
|
|
|
|
-- Chassis Utilization Table, includes CPU and Memory Utilization information
|
|
|
|
|
|
s5ChasUtilTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasUtilEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains CPU and memory utilization
|
|
information."
|
|
::= { s5ChasUtil 1 }
|
|
|
|
s5ChasUtilEntry OBJECT-TYPE
|
|
SYNTAX S5ChasUtilEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the s5ChasUtilTable. Rows
|
|
in this table will exist for each existing
|
|
row in the s5ChasComTable which represents
|
|
any chassis component for which CPU and/or
|
|
memory utilization values are available.
|
|
The values of the indices of a row in this
|
|
table will be equal to those of the
|
|
corresponding row in the s5ChasComTable."
|
|
INDEX { s5ChasUtilGrpIndx,
|
|
s5ChasUtilIndx,
|
|
s5ChasUtilSubIndx }
|
|
::= { s5ChasUtilTable 1 }
|
|
|
|
S5ChasUtilEntry ::= SEQUENCE {
|
|
s5ChasUtilGrpIndx Integer32,
|
|
s5ChasUtilIndx Integer32,
|
|
s5ChasUtilSubIndx Integer32,
|
|
s5ChasUtilTotalCPUUsage Gauge32,
|
|
s5ChasUtilCPUUsageLast1Minute Gauge32,
|
|
s5ChasUtilCPUUsageLast10Minutes Gauge32,
|
|
s5ChasUtilCPUUsageLast1Hour Gauge32,
|
|
s5ChasUtilCPUUsageLast24Hours Gauge32,
|
|
s5ChasUtilMemoryAvailable Gauge32,
|
|
s5ChasUtilMemoryMinAvailable Gauge32,
|
|
s5ChasUtilCPUUsageLast10Seconds Gauge32,
|
|
s5ChasUtilMemoryTotalMB Gauge32,
|
|
s5ChasUtilMemoryAvailableMB Gauge32
|
|
}
|
|
|
|
s5ChasUtilGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the chassis level group which
|
|
contains this component, corresponds to
|
|
s5ChasComGrpIndx."
|
|
::= { s5ChasUtilEntry 1 }
|
|
|
|
s5ChasUtilIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the component in the group.
|
|
Corresponds to s5ChasComIndx."
|
|
::= { s5ChasUtilEntry 2 }
|
|
|
|
s5ChasUtilSubIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-component index. Corresponds to
|
|
s5ChasComSubIndx."
|
|
::= { s5ChasUtilEntry 3 }
|
|
|
|
s5ChasUtilTotalCPUUsage OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy since system initialization."
|
|
::= {s5ChasUtilEntry 4}
|
|
|
|
s5ChasUtilCPUUsageLast1Minute OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy over the last 1 minute."
|
|
::= {s5ChasUtilEntry 5}
|
|
|
|
s5ChasUtilCPUUsageLast10Minutes OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy over the last 10 minutes."
|
|
::= {s5ChasUtilEntry 6}
|
|
|
|
s5ChasUtilCPUUsageLast1Hour OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy over the last 1 hour."
|
|
::= {s5ChasUtilEntry 7}
|
|
|
|
s5ChasUtilCPUUsageLast24Hours OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy over the last 24 hours."
|
|
::= {s5ChasUtilEntry 8}
|
|
|
|
s5ChasUtilMemoryAvailable OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of dynamic memory that
|
|
is currently free. This is measured as a percentage of
|
|
the memory the was available immediately after system
|
|
initialization."
|
|
::= {s5ChasUtilEntry 9}
|
|
|
|
s5ChasUtilMemoryMinAvailable OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the lowest percentage of dynamic
|
|
memory that has been free since system initialization.
|
|
This is a 'low-water mark' for memory utilization, and is
|
|
essentially the lowest value of s5ChasUtilMemoryUsage
|
|
since system initialization."
|
|
::= {s5ChasUtilEntry 10}
|
|
|
|
s5ChasUtilCPUUsageLast10Seconds OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the percentage of time the CPU has been
|
|
busy over the last 10 seconds."
|
|
::= {s5ChasUtilEntry 11}
|
|
|
|
s5ChasUtilMemoryTotalMB OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..1024)
|
|
UNITS "MegaBytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the total RAM of unit."
|
|
::= { s5ChasUtilEntry 12 }
|
|
|
|
s5ChasUtilMemoryAvailableMB OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..1024)
|
|
UNITS "MegaBytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the available RAM of unit."
|
|
::= { s5ChasUtilEntry 13 }
|
|
|
|
|
|
|
|
-- Chassis Power Supply Table
|
|
|
|
|
|
s5ChasPsRpsuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasPsRpsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains extended information on
|
|
RPSU power supply components."
|
|
::= { s5ChasPs 1 }
|
|
|
|
s5ChasPsRpsuEntry OBJECT-TYPE
|
|
SYNTAX S5ChasPsRpsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the s5ChasPsRpsuTable. Rows
|
|
in this table will exist for each existing
|
|
row in the s5ChasComTable which represents
|
|
any RPSU power supply. The values of the
|
|
indices of a row in this table will be equal
|
|
to those of the corresponding row in the
|
|
s5ChasComTable."
|
|
INDEX { s5ChasPsRpsuGrpIndx,
|
|
s5ChasPsRpsuIndx,
|
|
s5ChasPsRpsuSubIndx }
|
|
::= { s5ChasPsRpsuTable 1 }
|
|
|
|
S5ChasPsRpsuEntry ::= SEQUENCE {
|
|
s5ChasPsRpsuGrpIndx Integer32,
|
|
s5ChasPsRpsuIndx Integer32,
|
|
s5ChasPsRpsuSubIndx Integer32,
|
|
s5ChasPsRpsuType INTEGER,
|
|
s5ChasPsRpsuSourceConfig INTEGER
|
|
}
|
|
|
|
s5ChasPsRpsuGrpIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the chassis level group which
|
|
contains this component, corresponds to
|
|
s5ChasComGrpIndx."
|
|
::= { s5ChasPsRpsuEntry 1 }
|
|
|
|
s5ChasPsRpsuIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the component in the group.
|
|
Corresponds to s5ChasComIndx."
|
|
::= { s5ChasPsRpsuEntry 2 }
|
|
|
|
s5ChasPsRpsuSubIndx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32767)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-component index. Corresponds to
|
|
s5ChasComSubIndx."
|
|
::= { s5ChasPsRpsuEntry 3 }
|
|
|
|
s5ChasPsRpsuType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bayStack10(1),
|
|
nes(2),
|
|
bayStack15(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object returns the specific type of RPSU.
|
|
It can be set to indicate to the system the type
|
|
of installed RPSU in cases where the RPSU type
|
|
cannot be automatically detected."
|
|
::= {s5ChasPsRpsuEntry 4}
|
|
|
|
s5ChasPsRpsuSourceConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ups(1),
|
|
rpsu(2),
|
|
powerSharing(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to specify how a particular
|
|
RPSU should be used by the system, as follows:
|
|
|
|
ups(1)
|
|
Indicates that the RPSU should be used only as
|
|
an uninterruptible power source for devices
|
|
attached to powered ethernet ports.
|
|
|
|
rpsu(2)
|
|
Indicates that the RPSU should be used only as
|
|
a source of backup power for the device itself.
|
|
|
|
powerSharing(3)
|
|
Indicates that the RPSU should be used both as
|
|
a source of backup power for the device, and as
|
|
a UPS for devices attached to powered ethernet
|
|
ports."
|
|
::= {s5ChasPsRpsuEntry 5}
|
|
|
|
|
|
-- Notification auxiliary objects
|
|
|
|
s5ChasNotifyFanDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
left(1),
|
|
right(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used in the s5CtrFanDirectionError notification to
|
|
indicate fan direction."
|
|
::= { s5ChasNotify 1 }
|
|
|
|
|
|
-- GBIC Information Table
|
|
|
|
s5ChasGbicInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF S5ChasGbicInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains information about
|
|
pluggable ports."
|
|
::= { s5ChasPluggables 1}
|
|
|
|
s5ChasGbicInfoEntry OBJECT-TYPE
|
|
SYNTAX S5ChasGbicInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the s5ChasGbicInfoTable."
|
|
INDEX { s5ChasGbicInfoIfIndex }
|
|
::= { s5ChasGbicInfoTable 1 }
|
|
|
|
S5ChasGbicInfoEntry ::= SEQUENCE {
|
|
s5ChasGbicInfoIfIndex InterfaceIndex,
|
|
s5ChasGbicInfoGbicType DisplayString,
|
|
s5ChasGbicInfoWavelength Integer32,
|
|
s5ChasGbicInfoVendorName DisplayString,
|
|
s5ChasGbicInfoVendorOui OCTET STRING,
|
|
s5ChasGbicInfoVendorPartNo DisplayString,
|
|
s5ChasGbicInfoVendorRevision DisplayString,
|
|
s5ChasGbicInfoVendorSerial DisplayString,
|
|
s5ChasGbicInfoHwOptions BITS,
|
|
s5ChasGbicInfoDateCode DisplayString,
|
|
s5ChasGbicInfoCleiCode DisplayString,
|
|
s5ChasGbicInfoProductCode DisplayString
|
|
}
|
|
|
|
s5ChasGbicInfoIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each interface."
|
|
::= { s5ChasGbicInfoEntry 1 }
|
|
|
|
s5ChasGbicInfoGbicType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of pluggable part."
|
|
::= { s5ChasGbicInfoEntry 2 }
|
|
|
|
s5ChasGbicInfoWavelength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The wavelength value measured in nanometers for the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 3 }
|
|
|
|
s5ChasGbicInfoVendorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the vendor of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 4 }
|
|
|
|
s5ChasGbicInfoVendorOui OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (3))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Organizationally Unique Identifier (OUI) of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 5 }
|
|
|
|
s5ChasGbicInfoVendorPartNo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor part number of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 6 }
|
|
|
|
s5ChasGbicInfoVendorRevision OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor revision of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 7 }
|
|
|
|
s5ChasGbicInfoVendorSerial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor serial number for the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 8 }
|
|
|
|
s5ChasGbicInfoHwOptions OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
rxLoss(0),
|
|
txFault(1),
|
|
txDisable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardware options supported by the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 9 }
|
|
|
|
s5ChasGbicInfoDateCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturing date of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 10 }
|
|
|
|
s5ChasGbicInfoCleiCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Common Language Equipment Identification Code of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 11 }
|
|
|
|
s5ChasGbicInfoProductCode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The product code of the pluggable part."
|
|
::= { s5ChasGbicInfoEntry 12 }
|
|
|
|
END
|
|
|