mibs/MIBS/packetlight/SL-SFP-MIB
2023-12-05 12:25:34 +01:00

2592 lines
88 KiB
Plaintext
Raw Blame History

-- *****************************************************************
-- SFP MIB
-- *****************************************************************
SL-SFP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, Integer32, TimeTicks
FROM SNMPv2-SMI
Float32TC, Float64TC, Float128TC FROM FLOAT-TC-MIB
DisplayString, TruthValue,
TimeStamp FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex FROM IF-MIB
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
CleiCode FROM SL-ENTITY-MIB
sitelight FROM SL-NE-MIB;
slSfp MODULE-IDENTITY
LAST-UPDATED "200501250000Z"
ORGANIZATION "PacketLight Networks Ltd."
CONTACT-INFO
"Omri_Viner@PacketLight.com"
DESCRIPTION
"This MIB module describes the SFP Modules"
::= { sitelight 10 }
-- The SFP MIB consists of the following groups:
-- SFP Configuration Table
-- SFP Diagnostic Table
-- SFP Traps
sfpConf OBJECT IDENTIFIER ::= { slSfp 1 }
sfpDiag OBJECT IDENTIFIER ::= { slSfp 2 }
sfpTraps OBJECT IDENTIFIER ::= { slSfp 3 }
sfpTune OBJECT IDENTIFIER ::= { slSfp 4 }
-- Textual Conventions
-- ----------------------------------------------------
--
-- The SFP Configuration Table
--
-- ----------------------------------------------------
sfpConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SFP configuration table.
The table defines the configuration of the SFP-1310 and
the SFP-WDM modules."
::= { sfpConf 1 }
sfpConfigEntry OBJECT-TYPE
SYNTAX SfpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SFP configuration table.
The index to this table is the same as the ifIndex of the SFP.
The SFP Config Table contain and entry for each
module of a type SFP."
INDEX { sfpConfigInterface }
::= { sfpConfigTable 1 }
SfpConfigEntry ::=
SEQUENCE {
sfpConfigInterface InterfaceIndex,
-- Base ID Fields
sfpConfigXcvrId INTEGER,
sfpConfig1310ExtXcvrId INTEGER, -- 1310
sfpConfigWdmExtXcvrId INTEGER, -- 15xy
sfpConfigConnectorCode INTEGER,
sfpConfigInfibandCompliance INTEGER,
sfpConfigEsconCompliance INTEGER,
sfpConfigSonetCompliance INTEGER,
sfpConfigGbeCompliance INTEGER,
sfpConfigFcCompliance INTEGER,
sfpConfigEncodingCode INTEGER,
sfpConfigNominalBitRate INTEGER,
sfpConfigLength9mKm INTEGER,
sfpConfigLength9m100m INTEGER, -- 1310
sfpConfigLength50m10m INTEGER, -- 1310
sfpConfigLength62m10m INTEGER, -- 1310
sfpConfigLengthCopper1m INTEGER, -- 1310
sfpConfigMaxTemp INTEGER, -- 15xy
sfpConfigMinTemp INTEGER, -- 15xy
sfpConfigMaxSupplyCurrent INTEGER, -- 15xy
sfpConfigChannelSpacing INTEGER, -- 15xy
sfpConfigVendorName SnmpAdminString,
sfpConfigOptionalWdm INTEGER, -- 15xy
sfpConfigVendorOUI INTEGER,
sfpConfigVendorPN SnmpAdminString,
sfpConfigVendorRev SnmpAdminString,
sfpConfigWaveLength INTEGER, -- 15xy only
-- Extended ID Fields
sfpConfigExtendedOptions INTEGER,
sfpConfigMaxBitRate INTEGER,
sfpConfigMinBitRate INTEGER,
sfpConfigVendorSN SnmpAdminString,
sfpConfigDateCode SnmpAdminString,
sfpConfigDiagnosticMonitoring INTEGER,
sfpConfigEnhanceOptions INTEGER,
sfpConfig8472Compliance INTEGER,
sfpConfigTunableWaveLength INTEGER, -- 15xy
sfpConfigVoaControl INTEGER, -- 15xy
sfpConfigVdtControl INTEGER, -- 15xy
sfpConfigPilotToneModulation INTEGER, -- 15xy
-- Non standard Fields
sfpConfigCleiCode DisplayString,
-- XFP standard Fields
sfpConfigXfpExtXcvrId INTEGER,
sfpConfigXfpEncodingCode INTEGER,
sfpConfigXfpMinBitRate INTEGER,
sfpConfigXfpMaxBitRate INTEGER,
sfpConfig10GSonetCompliance INTEGER,
sfpConfig10GbeCompliance INTEGER,
sfpConfig10GFcCompliance INTEGER,
sfpConfigXfpDeviceTech INTEGER,
-- XFP SFP-8477 Extended Fields (Tuning and Dither)
sfpConfigXfpTuningSupported INTEGER,
sfpConfigXfpDesiredWl INTEGER,
sfpConfigXfpWlError INTEGER,
sfpConfigXfpDesiredChannel INTEGER,
sfpConfigXfpDesiredFreq INTEGER,
sfpConfigXfpFreqError INTEGER,
sfpConfigXfpDitherSupported TruthValue,
sfpConfigXfpDitherAdmin INTEGER,
sfpConfigXfpCapFreqFirstThz INTEGER,
sfpConfigXfpCapFreqFirst10Ghz INTEGER,
sfpConfigXfpCapFreqLastThz INTEGER,
sfpConfigXfpCapFreqLast10Ghz INTEGER,
sfpConfigXfpCapMaxSpacing10Ghz INTEGER,
sfpConfigXfpCalibrationSupported TruthValue,
sfpConfigXfpCalibrationEnabled TruthValue,
-- CFP MSA Rev 1.4
sfpConfigCfpExtId INTEGER,
sfpConfigCfpConnectorType INTEGER,
sfpConfigCfpEthernetCode INTEGER,
sfpConfigCfpFcCode INTEGER,
sfpConfigCfpCopperCode INTEGER,
sfpConfigCfpSonetCode INTEGER,
sfpConfigCfpOtnCode INTEGER,
sfpConfigCfpSupportedRates INTEGER,
sfpConfigCfpSupportedLanes INTEGER,
sfpConfigCfpMediaProperties INTEGER,
sfpConfigCfpMaxNetworkLaneRate INTEGER,
sfpConfigCfpMaxHostLaneRate INTEGER,
sfpConfigCfpMaxSmFiberLength INTEGER,
sfpConfigCfpMaxMmFiberLength INTEGER,
sfpConfigCfpMaxCopperCableLength INTEGER,
sfpConfigCfpMinWavelenPerActive INTEGER,
sfpConfigCfpMaxWavelenPerActive INTEGER,
sfpConfigCfpMaxLenOpticalWidth INTEGER,
sfpConfigCfpSpacing INTEGER,
-- QSFP+ SFF-8436
sfpConfigQsfppEthernetCode INTEGER,
sfpConfigQsfppSonetCode INTEGER,
-- CXP
sfpConfigCxpExtId INTEGER,
sfpConfigCxpConnectorType INTEGER,
sfpConfigCxpMaxSupportedRate INTEGER,
sfpConfigCxpNominalWavelength INTEGER,
sfpConfigCxpDeviceTech INTEGER,
-- Coherent
sfpConfigCohRxDesiredChannel INTEGER,
sfpConfigCohRxDesiredWl INTEGER,
sfpConfigCohRxDesiredFreq INTEGER,
sfpConfigCohCurrentCD INTEGER,
sfpConfigCohCurrentOSNR INTEGER,
sfpConfigCohAverageOSNR INTEGER,
sfpConfigCohMaxCD INTEGER,
-- DSP
sfpConfigNyquist TruthValue
}
sfpConfigInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interface Index of the SFP (type=196)."
::= { sfpConfigEntry 1 }
-- Base ID Fields
sfpConfigXcvrId OBJECT-TYPE
SYNTAX INTEGER {
unknone(0), -- Unknown or unspecified
gbic(1), -- GBIC
module(2), -- Module/connector soldered to motherboard
sfp1310(3), -- 1310 SFP
xfp(6), -- XFP
sfpDwdm(11), -- DWDM SFP
qsfp(12), -- QSFP
qsfpPlus(13), -- QSFP+
cfp(14), -- CFP
cxp(15), -- CXP
coherent(16), -- Coherent
qsfp28(17), -- QSFP28
cfp2(20) -- CFP2
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identifier value specifies the physical device described by the serial information.
This value shall be included in the serial data. The defined identifier values are:
00h - Unknown or unspecified
01h - GBIC
02h - Module/connector soldered to motherboard
03h - 1310 SFP
04-0Ah - Reserved for XFP and other platforms
0Bh - DWDM SFP
80-FFh - Vendor specific."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.2,
SFP-8472 Table 3.1 and 3.2"
::= { sfpConfigEntry 2 }
sfpConfig1310ExtXcvrId OBJECT-TYPE
SYNTAX INTEGER {
modDef0(0), -- GBIC definition is not specified or not compliant with a defined MOD_DEF
modDef1(1), -- GBIC is compliant with MOD_DEF 1
modDef2(2), -- GBIC is compliant with MOD_DEF 2
modDef3(3), -- GBIC is compliant with MOD_DEF 3
modDef4(4), -- GBIC/SFP function is defined by serial ID only
modDef5(5), -- GBIC is compliant with MOD_DEF 5
modDef6(6), -- GBIC is compliant with MOD_DEF 6
modDef7(7) -- GBIC is compliant with MOD_DEF 7
}
MAX-ACCESS read-only
STATUS current -- 1310
DESCRIPTION
"The extended identifier value provides additional information about the 1310 transceiver.
The defined identifier values are:
00h GBIC definition is not specified or the GBIC
definition is not compliant with a defined
MOD_DEF. See product specification for details.
01h GBIC is compliant with MOD_DEF 1
02h GBIC is compliant with MOD_DEF 2
03h GBIC is compliant with MOD_DEF 3
04h GBIC/SFP function is defined by serial ID only
05h GBIC is compliant with MOD_DEF 5
06h GBIC is compliant with MOD_DEF 6
07h GBIC is compliant with MOD_DEF 7
08-FFh Reserved"
REFERENCE "SFP-8472 Table 3.1 and 3.3"
::= { sfpConfigEntry 3 }
sfpConfigWdmExtXcvrId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"This field is used to distinguish between different types of DWDM transceivers and
different power and environmental classes. The defined identifier values are:
Bits 7..6: Reserved
Bits 5..4: Class of WDM
00: no WDM
01: CWDM
10: DWDM
Bits 3..2: Class of power
00: P<1W
01: [1W,1.5W]
10: P>1.5W
11: reserved
Bits 3..2: Class of temp
00: [-5, 70C]
01: [1W,1.5W]
10: reserved
11: Defined by Bytes 15 - 16."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.3"
::= { sfpConfigEntry 4 }
sfpConfigConnectorCode OBJECT-TYPE
SYNTAX INTEGER {
conUnknown(0), -- Unknown or unspecified
conSc(1), -- SC
conFcCopper1(2), -- Fibre Channel Style 1 copper connector
conFcCopper2(3), -- Fibre Channel Style 2 copper connector
conBncTnc(4), -- BNC/TNC
conFcCoaxial(5), -- Fibre Channel coaxial headers
conFiberJack(6), -- FiberJack
conLc(7), -- LC
conMtRj(8), -- MT-RJ
conMu(9), -- MU
comSg(10), -- SG
conOpticalPigtail(11), -- Optical pigtail
conHssdc2(32), -- HSSDC II
conCopperPigtail(33) -- Optical pigtail
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The identifier value specifies the physical device described by the serial information.
This value shall be included in the serial data. The defined identifier values are:
00h - Unknown or unspecified
01h - SC
02h - Fibre Channel Style 1 copper connector
03h - Fibre Channel Style 2 copper connector
04h - BNC/TNC
05h - Fibre Channel coaxial headers
06h - FiberJack
07h - LC
08h - MT-RJ
09h - MU
0Ah - SG
0Bh - Optical pigtail
0Ch - 1Fh - Reserved
20h - HSSDC II
21h - Copper Pigtail
22h - 7Fh - Reserved
80-FFh - Vendor specific."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.4,
SFP-8472 Table 3.1 and 3.4."
::= { sfpConfigEntry 5 }
sfpConfigInfibandCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the Infiband interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0: 1X SX
Bits 1: 1X LX
Bits 2: 1X Copper Active
Bits 3: 1X Copper Passive."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
SFP-8472 Table 3.1 and 3.5."
::= { sfpConfigEntry 6 }
sfpConfigEsconCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only -- 1310
STATUS current
DESCRIPTION
"The following bit significant indicators define the ESCON interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0: ESCON MMF, 1310nm LED
Bits 1: ESCON SMF, 1310nm Laser"
REFERENCE "SFP-8472 Table 3.1 and 3.5."
::= { sfpConfigEntry 7 }
sfpConfigSonetCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the SONET interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0: SONET reach specifier bit 1
Bits 1: SONET reach specifier bit 2
Where:
00 speed OC-3/OC-12/OC-48 Short reach - SONET SR compliant
10 speed OC-3/OC-12/OC-48 Short reach - SONET SR-1 compliant
10 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-1 compliant
01 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-2 compliant
10 speed OC-3/OC-12/OC-48 Long reach - SONET LR-1 compliant
01 speed OC-3/OC-12/OC-48 Long reach - SONET LR-2 compliant
11 speed OC-3/OC-12/OC-48 Long reach - SONET LR-3 compliant
Bits 2: OC-48, single mode long reach
Bits 3: OC-48, single mode inter. reach
Bits 4: OC-48, multi-mode short reach
Bits 5: OC-12, single mode long reach
Bits 6: OC-12, single mode inter. reach
Bits 7: OC-12 multi-mode short reach
Bits 8: OC-3, single mode long reach
Bits 9: OC-3, single mode inter. reach
Bits 10: OC-3, multi-mode short reach."
REFERENCE "DWDM MSA Table 2.3.1, 2.3.5 and 2.3.5a,
SFP-8472 Table 3.1, 3.5 and 3.5a."
::= { sfpConfigEntry 8 }
sfpConfigGbeCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the Infiband interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0: 1000BASE-T
Bits 1: 1000BASE-CX
Bits 2: 1000BASE-LX
Bits 3: 1000BASE-SX
Bits 4: 100BASE-LX/LX10 -- 1310
Bits 5: 100BASE-FX -- 1310
Bits 6: BASE-BX10 -- 1310
Bits 7: BASE-PX." -- 1310
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
SFP-8472 Table 3.1 and 3.5"
::= { sfpConfigEntry 9 }
sfpConfigFcCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the FC interfaces
that are supported by the transceiver. The defined identifier values are:
- Fibre Channel link length:
Bits 0: very long distance (V)
Bits 1: short distance (S)
Bits 2: intermediate distance (I)
Bits 3: long distance (L)
- Fibre Channel transmitter technology
Bits 4: Longwave laser (LC)
Bits 5: Electrical inter-enclosure (EL)
Bits 6: Electrical intra-enclosure (EL)
Bits 7: Shortwave laser w/o OFC (SN)
Bits 8: Shortwave laser w/ OFC (SL)
Bits 9: Longwave laser (LL)
Bits 10: Copper Active -- 1310
Bits 11: Copper Passive -- 1310
- Fibre Channel transmission media
Bits 12: Twin Axial Pair (TW)
Bits 13: Shielded Twisted Pair (TP)
Bits 14: Miniature Coax (MI)
Bits 15: Video Coax (TV)
Bits 16: Multi-mode, 62.5m (M6)
Bits 17: Multi-mode, 50 m (M5)
Bits 18: Single Mode (SM)
- Fibre Channel speed
Bits 19: 800 MB/Sec
Bits 20: 400 MB/Sec
Bits 21: 200 MB/Sec
Bits 22: 100 MB/Sec
Bits 23: 1200 MB/Sec
Bits 24: 1600 MB/Sec."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
SFP-8472 Table 3.1 and 3.5"
::= { sfpConfigEntry 10 }
sfpConfigEncodingCode OBJECT-TYPE
SYNTAX INTEGER {
encUnspecified(0), -- Unspecified
enc8B10B(1), -- 8B10B
enc4B5B(2), -- 4B5B
encNrz(3), -- NRZ
encManchester(4), -- Manchester
encSonet(5), -- SONET Scrambled
enc64B66B(6) -- 64B/66B
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encoding value indicates the serial encoding mechanism that is the
nominal design target of the particular transceiver.
The value shall be contained in the serial data.
The defined encoding values are:
00h: Unspecified
01h: 8B10B
02h: 4B5B
03h: NRZ
04h: Manchester
05h: SONET Scrambled
06h -FFh: Reserved."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.6,
SFP-8472 Table 3.1 and 3.6"
::= { sfpConfigEntry 11 }
sfpConfigNominalBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The nominal bit rate (BR, nominal) is specified in units of 100 Megabits
per second, rounded off to the nearest 100 Megabits per second.
The bit rate includes those bits necessary to encode and delimit the
signal as well as those bits carrying data information.
A value of 0 indicates that the bit rate is not specified and must be
determined from the transceiver technology.
The actual information transfer rate will depend on the encoding of the data,
as defined by the encoding value."
REFERENCE "DWDM MSA Table 2.3.1."
::= { sfpConfigEntry 12 }
sfpConfigLength9mKm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Addition to EEPROM data from original GBIC definition.
This value specifies the link length that is supported by the transceiver while
operating in compliance with the applicable standards using single mode fiber.
A value of zero means that the transceiver does not support single mode
fiber or that the length information must be determined from the transceiver
technology."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 13 }
sfpConfigLength9m100m OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 1310
DESCRIPTION
"This value specifies the link length that is supported by the transceiver
while operating in compliance with the applicable standards using
single mode fiber.
The value is in units of 100 meters. A value of 255 means that the transceiver
supports a link length greater than 25.4 km.
A value of zero means that the transceiver does not support single mode
fiber or that the length information must be determined from the transceiver
technology."
REFERENCE "SFP-8472 Table 3.1."
::= { sfpConfigEntry 14 }
sfpConfigLength50m10m OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 1310
DESCRIPTION
"This value specifies the link length that is supported by the transceiver
while operating in compliance with the applicable standards using 50 micron
multi-mode fiber.
The value is in units of 10 meters. A value of 255 means that the transceiver
supports a link length greater than 2.54 km.
A value of zero means that the transceiver does not support 50 micron
multimode fiber or that the length information must be determined from the
transceiver technology."
REFERENCE "SFP-8472 Table 3.1."
::= { sfpConfigEntry 15 }
sfpConfigLength62m10m OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 1310
DESCRIPTION
"This value specifies the link length that is supported by the transceiver
while operating in compliance with the applicable standards using 62.5 micron
multi-mode fiber.
The value is in units of 10 meters. A value of 255 means that the transceiver
supports a link length greater than 2.54 km.
A value of zero means that the transceiver does not support 50 micron
multimode fiber or that the length information must be determined from the
transceiver technology.
It is common for the transceiver to support both 50 micron and 62.5 micron
fiber."
REFERENCE "SFP-8472 Table 3.1."
::= { sfpConfigEntry 16 }
sfpConfigLengthCopper1m OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 1310
DESCRIPTION
"This value specifies the link length that is supported by the transceiver
while operating in compliance with the applicable standards using copper cable.
The value is in units of 1 meter. A value of 255 means that the transceiver
supports a link length greater than 254 meters.
A value of zero means that the transceiver does not support copper cables
or that the length information must be determined from the
transceiver technology."
REFERENCE "SFP-8472 Table 3.1."
::= { sfpConfigEntry 17 }
sfpConfigMaxTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"This field defines the maximum operating case temperature the module is
rated for. The maximum case temperature is encoded as a signed two<77>s
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
This field should be used even if a standard operating temperature class
is indicated in the Extended Indentifier Byte (Byte 1)."
REFERENCE "DWDM MSA Table 2.3.1."
::= { sfpConfigEntry 18 }
sfpConfigMinTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"This field defines the minimum operating case temperature the module is
rated for. The maximum case temperature is encoded as a signed two<77>s
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
This field should be used even if a standard operating temperature class
is indicated in the Extended Indentifier Byte."
REFERENCE "DWDM MSA Table 2.3.1."
::= { sfpConfigEntry 19 }
sfpConfigMaxSupplyCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"This field defines the maximum supply current the module will consume
under worst case conditions. The maximum current is the byte value * 4mA."
REFERENCE "DWDM MSA Table 2.3.1."
::= { sfpConfigEntry 20 }
sfpConfigChannelSpacing OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"In the case of SFP:
This bit field value identifies the densest channel spacing
the module is compatible with and the number of channels over which the
module may be tuned by user command.
If not tunable, the number of channels is entered as 1.
The bit fields are:
Bits 7..6: Channel Spacing
00: 200 GHz (DWDM)
01: 100 GHz (DWDM)
10: 50 Ghz (DWDM)
11: Reserved
Bits 5..0: Number of channels (1 <20> 63).
In the case of XFP:
The value of this field is equal to the guaranteed range of laser
wavelength (+/- value) from Nominal wavelength.
(Wavelength Tol. = value/200 in nm)"
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.7. XFP INF-8077i Section 5.34."
::= { sfpConfigEntry 21 }
sfpConfigVendorName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor name is a 16 character field that contains ASCII characters,
left-aligned and padded on the right with ASCII spaces (20h).
The vendor name shall be the full name of the corporation,
a commonly accepted abbreviation of the name of the corporation,
the SCSI company code for the corporation, or the stock exchange code
for the corporation.
At least one of the vendor name or the vendor OUI fields shall contain
valid serial data."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 22 }
sfpConfigOptionalWdm OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"The bits in the option field shall specify the options implemented
in the transceiver. The following bits are defined:
Bits 7: Optional Interrupt Pin Functionality Supported (1 if supported)
Bits 6..4: Pilot Tone Functionality
000b: No Pilot Tone Functionality
001b: Pilot Tone Detection Only
010b: Pilot Tone Injection Only
011b: Pilot Tone Injection and Detection
100b: Enhanched Pilot Tone Functionality
101b-111b: Reserved
Bits 3: Variable Optical Attenuator Implemented (1 if implemented)
Bits 2: Extended Transmit Power Monitoring
0: Default (SFF-8472) TX Power Monitoring
1: Extended TX Power Monitoring (+18.2 dBm max)
Bits 1: Wavelength Monitor Type in A2 Byte 106-107
0: Monitor is Wavelength
1: Monitor is Laser Temperature
Bits 0: Variable Decision Threshold (1 if implemented)"
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.8."
::= { sfpConfigEntry 23 }
sfpConfigVendorOUI OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor organizationally unique identifier field (vendor OUI)
is a 3-byte field that contains the IEEE Company Identifier for the
vendor. A value of all zero in the 3-byte field indicates that
the Vendor OUI is unspecified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 24 }
sfpConfigVendorPN OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor part number (vendor PN) is a 16-byte field that contains
ASCII characters, left-aligned and padded on the right with ASCII
spaces (20h), defining the vendor part number or product name.
A value of all zero in the 16-byte field indicates that the
vendor PN is unspecified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 25 }
sfpConfigVendorRev OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor revision number (vendor rev) is a 4-byte field that
contains ASCII characters, left-aligned and padded on the right with
ASCII spaces (20h), defining the vendor<6F>s product revision number.
A value of all zero in the 4-byte field indicates that
the vendor PN is unspecified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 26 }
sfpConfigWaveLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"In the case of DWDM:
Nominal transmitter output wavelength in units of 0.01nm.
As an example, a wavelength of 1550.51nm would be encoded as: 155051.
In the case of 1310:
The laser wavelength is equal to the the integer value in nm with 00 at
the end.
As an example, a wavelength of 1310 would be encoded as: 131000."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 27 }
-- Extended ID Fields
sfpConfigExtendedOptions OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the bitmap options implemented in the transceiver as described in.
The bits definition is:
5 RATE_SELECT is implemented
NOTE: Lack of implemention does not indicate lack of
simultaneous compliance with multiple standard rates.
Compliance with particular standards should be determined
from Transceiver Code.
4 TX_DISABLE is implemented and disables the serial output.
3 TX_FAULT signal implemented. (See SFP MSA)
2 Loss of Signal implemented, signal inverted from standard
definition in SFP MSA.
NOTE: This is not standard SFP/GBIC behavior and should
be avoided, since non-interoperable behavior results.
1 Loss of Signal implemented, signal as defined in SFP MSA."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.9, SFP-8472 Table 3.1 and 3.7."
::= { sfpConfigEntry 28 }
sfpConfigMaxBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The upper bit rate limit at which the transceiver will still meet its
specifications (BR, max) is specified in units of 1% above the nominal
bit rate.
A value of zero indicates that this field is not specified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 29 }
sfpConfigMinBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lower bit rate limit at which the transceiver will still meet its
specifications (BR, min) is specified in units of 1% below the nominal
bit rate.
A value of zero indicates that this field is not specified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 30 }
sfpConfigVendorSN OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The vendor serial number (vendor SN) is a 16 character field that
contains ASCII characters, left-aligned and padded on the right with
ASCII spaces (20h), defining thevendor<6F>s serial number for the transceiver.
A value of all zero in the 16-byte field indicates that the vendor PN is
unspecified."
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
::= { sfpConfigEntry 31 }
sfpConfigDateCode OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date code is an 6-byte field that contains the vendor<6F>s date
code in ASCII characters. The date code is mandatory.
The date code shall be in the format: <yy><mm><dd>."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.10, SFP-8472 Table 3.1 and 3.8."
::= { sfpConfigEntry 32 }
sfpConfigDiagnosticMonitoring OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A field with 8 single bit indicators which describe the
optional digital diagnostic features implemented in the transceiver.
Since transceivers will not necessarily implement all optional
features described in this document, the <20>Enhanced Options<6E> bit field
allows the host system to determine which functions are
available over the 2 wire serial bus.
The bits assignment is:
7 Reserved for legacy diagnostic implementations.
Must be <20>0<EFBFBD> for compilance with this document.
6 Digital diagnostic monitoring implemented (described in this document).
Must be <20>1<EFBFBD> for compliance with this document.
5 Internally Calibrated
4 Externally Calibrated
3 Received power measurement type 0 = OMA, 1 = Average Power
2 Address change required."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.11, SFP-8472 Table 3.1 and 3.9."
::= { sfpConfigEntry 33 }
sfpConfigEnhanceOptions OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A field with 6 single bit indicators which describe the
optional digital diagnostic features implemented in the transceiver.
Since transceivers will not necessarily implement all optional features
described in this document, the <20>Enhanced Options<6E> bit field allows the
host system to determine which functions are available over the 2 wire
serial bus. A <20>1<EFBFBD> indicates that the particular function is
implemented in the transceiver..
The bits assignment is:
Bits 7: Optional Alarm/warning flags implemented for all monitored quantities
Bits 6: Optional Soft TX_DISABLE control and monitoring implemented
Bits 5: Optional Soft TX_FAULT monitoring implemented
Bits 4: Optional Soft RX_LOS monitoring implemented
Bits 3: Option not enabled in DWDM.
8472- Optional Soft RATE_SELECT control and monitoring implemented
Bits 2: Option not enabled in DWDM.
8472- Optional Application Select control implemented per SFF-8079"
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.12, SFP-8472 Table 3.1 and 3.10."
::= { sfpConfigEntry 34 }
sfpConfig8472Compliance OBJECT-TYPE
SYNTAX INTEGER {
noDiag(0),
rev93(1),
rev94(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An unsigned integer that indicates which feature set(s) are
implemented in the transceiver.
The defined values are:
0 - Digital diagnostic functionality not included or undefined.
1 - Includes functionality described in Rev 9.3 SFF-8472.
2 - Includes functionality described in Rev 9.4 SFF-8472."
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.14, SFP-8472 Table 3.1 and 3.12."
::= { sfpConfigEntry 35 }
sfpConfigTunableWaveLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"Wavelength Tuning Control.
The availability of this function is indicated in the object sfpConfigChannelSpacing,
where number of channels greater than 1 indicates tunability.
The wavelength is set to the channel number written to this byte.
For a value of 0, channel 1 is selected. For values greater than the maximum channel number,
the maximum channel number is selected.
The object value is defaults to 1 on power-up."
REFERENCE "DWDM MSA Table 2.3.27."
::= { sfpConfigEntry 36 }
sfpConfigVoaControl OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"Variable Optical Attenuator Control.
Used to control the wavelength in tunable modules.
The availability of this function is indicated in Bit 3 of sfpConfigOptionalWdm.
The amount of attenuation set is given by the Byte value * 0.1 dB,
and thus ranges from 0 to 25.6 dB.
The object value defaults to 0 on power-up."
REFERENCE "DWDM MSA Table 2.3.28."
::= { sfpConfigEntry 37 }
sfpConfigVdtControl OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"Variable Decision Threshold Control.
Used to control the variable decision threshold function.
The availability of this function is indicated in Bit 0 of sfpConfigOptionalWdm.
The object value is a 2<>s complement 7 bit value (-128 - +127).
The decision threshold set is given by:
Decision Threshold = 50% + [VAL/256]*100%
The object value defaults to 0 on power-up corresponding to 50%."
REFERENCE "DWDM MSA Table 2.3.29."
::= { sfpConfigEntry 38 }
sfpConfigPilotToneModulation OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"Pilot Tone Injection Modulation Depth.
When basic MSA pilot tone injection functionality is implemented
(as indicated in the Serial ID fields by bits 4-6 of of sfpConfigOptionalWdm)
Tjis object may be used by the vendor to indicate modulation
depth per unit control swing on pin 7.
The modulation depth per control swing is given by:
Modulation Depth = 0.2% * VAL / Vpp(pin7)
A value of 0 indicates that the modulation depth per input swing
is within the range"
REFERENCE "DWDM MSA Table 2.3.30."
::= { sfpConfigEntry 39 }
sfpConfigCleiCode OBJECT-TYPE
SYNTAX DisplayString (SIZE (10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The COMMON LANGUAGE Equipment Code.
The CLEI code contains an intelligent
ten-character code that identifies the
telecommunications equipment.
The Clei Code resides in the SEEP of the SFP."
REFERENCE
"GR-383-CORE"
::= { sfpConfigEntry 40 }
--
-- XFP Information
--
sfpConfigXfpExtXcvrId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current -- xfp
DESCRIPTION
"This field is used to distinguish between different types of DWDM transceivers and
different power and environmental classes. The defined identifier values are:
Bits 7..6:
00: Power Level 1 Module (1.5 W max. power dissipation.)
01: Power Level 2 Module (2.5W Max)
10: Power Level 3 Module (3.5W max. power dissipation.)
11: Power Level 4 Module (>3.5W max. power dissipation.)
Bit 5: CDR exist
0: Module with CDR function
1: Non-CDR version of XFP
Bits 5: TX ref clock is required
0: TX Ref Clock Input Required
1: TX Ref Clock Input Not Required
Bits 3: CLEI code is present
0: No CLEI code present in Table 02h
1: CLEI code present in Table 02h
Bits 2..0: Resesrved"
REFERENCE "XFP INF-8077i Table 47."
::= { sfpConfigEntry 41 }
sfpConfigXfpEncodingCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The encoding value indicates the serial encoding mechanism that is the
nominal design target of the particular transceiver.
The value shall be contained in the serial data.
The defined encoding values are:
Bit 7: 64B/66B
Bit 6: 8B/10B
Bit 5: SONET scrambled
Bit 4: NRZ
Bit 3: RZ
Bits 2-0: Reserved."
REFERENCE "XFP INF-8077i Table 50."
::= { sfpConfigEntry 42 }
sfpConfigXfpMinBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum bit rate (BR, minimum) is specified in units of 100 Megabits
per second, rounded off to the nearest 100 Megabits per second. The bit
rate includes those bits necessary to encode and delimit the signal as well
as those bits carrying data information. A value of 0 indicates that the minimum
bit rate is not specified andmust be determined from the transceiver
technology. The actual information transfer rate will depend on the encoding
of the data, as defined by the encoding value. Specific CDR rate
support is indicated in Byte 164."
REFERENCE "XFP INF-8077i Section 5.20."
::= { sfpConfigEntry 43 }
sfpConfigXfpMaxBitRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum bit rate (BR, maximum) is specified in units of 100 Megabits
per second, rounded off to the nearest 100 Megabits per second. The
bit rate includes those bits necessary to encode and delimit the signal as
well as those bits carrying data information. A value of 0 indicates that the
maximum bit rate is not specified and must be determined from the transceiver
technology. The actual information transfer rate will depend on the
encoding of the data, as defined by the encoding value. Specific CDR rate
support is indicated in Byte 164."
REFERENCE "XFP INF-8077i Section 5.21."
::= { sfpConfigEntry 44 }
sfpConfig10GSonetCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the SONET interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0-1: Reserved
Bits 2: I-64.5 - 1550 nm, 25 km, SM, IO
Bits 3: I-64.3 - 1550 nm, 25 km, SM, IO
Bits 4: I-64.2 - 1550 nm, 25 km, SM, IO
Bits 5: I-64.2r - 1550 nm, 2 km, SM, VSR
Bits 6: I-64.1/VSR2000-2R1/P1I1-2D1 - 1310 nm, 2 km, SM, VSR
Bits 7: I-64.1r/VSR600-2R1 - 1310 nm, 0.6 km, Laser-MM Fibre-SM, VSR
Bits 8: Reserved
Bits 9: S-64.5b - 1550 nm, 40 km, SH
Bits 10: S-64.5a - 1550 nm, 40 km, SH
Bits 11: S-64.3b
Bits 12: S-64.3a - 1550 nm, 40 km, SM, SH
Bits 13: S-64.2b - 1550 nm, 40 km, SM, SH
Bits 14: S-64.2a - 1550 nm, 40 km, SM, SH
Bits 15: S-64.1 - 1310 nm, 20 km, IO
Bits 16-17: Reserved
Bits 18: G.959.1 P1L1-2D2 - 1550 nm, SM, 80 km, LH
Bits 19: L-64.3 - 1550 nm, 80 km, LH
Bits 20: L-64.2c - 1550 nm, 80 km, LH
Bits 21: L-64.2b - 1550 nm, 80 km, LH
Bits 22: L-64.2a - 1550 nm, 80 km, LH
Bits 23: L-64.1 - 1310 nm, SM, 40 km, SH
Bits 24-28: Reserved
Bits 29: V-64.3 - 1550 nm, SM, 120 km, VL
Bits 30: V-64.2b - 1550 nm, SM, 120 km, VL
Bits 31: V-64.2a - 1550 nm, SM, 120 km, VL."
REFERENCE "XFP MSA Table 49."
::= { sfpConfigEntry 45 }
sfpConfig10GbeCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the 10GbE interfaces
that are supported by the transceiver. The defined identifier values are:
Bits 0: Reserved
Bits 1: 10GBASE-EW - WAN, 1550 nm, SM, ER
Bits 2: 10GBASE-LW - WAN, 1310 nm, SM, LR
Bits 3: 10GBASE-SW - WAN, 850 nm, MM, SR
Bits 4: 10GBASE-LRM (Long reach Multimode) - LAN, 1310 nm, MM, SR fiber, 0.2 km, SR
Bits 5: 10GBASE-ER (extended range) - LAN, 1550 nm, SM, 40 km, ER
Bits 6: 10GBASE-LR (Long Range) - LAN, 1310 nm, SM, 10 km, LR
Bits 7: 10GBASE-SR - LAN, 850 nm, MM, 0.3 km, SR."
REFERENCE "XFP MSA Table 49."
::= { sfpConfigEntry 46 }
sfpConfig10GFcCompliance OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the 10GFC interfaces
that are supported by the transceiver. The defined identifier values are:
- Fibre Channel link length:
Bits 0-3: Reserved
Bits 4: Intermediate Reach 1300 nm FP - 1310 nm, SM, IR
Bits 5: Extended Reach 1550 nm - 1550 nm, SM, ER
Bits 6: 1200-SM-LL-L - 1310 nm, SM, LR
Bits 7: 1200-MX-SN-I - 850 nm, MM, IR."
REFERENCE "XFP MSA Table 49."
::= { sfpConfigEntry 47 }
sfpConfigXfpDeviceTech OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The following bit significant indicators define the XFP device technology:
Bits 0: 0-Transmitter not Tunable 1-Transmitter Tunable
Bits 1: Detector Type: 0-PIN detector 1-APD detector
Bits 2: Cooled transmitter
Bits 3: Wavelength control: 0-No wavelength control 1-Active wavelength control
Bits 4-7: Transmitter technology:
0000b 850 nm VCSEL
0001b 1310 nm VCSEL
0010b 1550 nm VCSEL
0011b 1310 nm FP
0100b 1310 nm DFB
0101b 1550 nm DFB
0110b 1310 nm EML
0111b 1550 nm EML
1000b Copper or others
1001b 1550 nm tunable
1111b-1001b Reserved."
REFERENCE "XFP MSA Table 51 and Table 52."
::= { sfpConfigEntry 48 }
sfpConfigXfpTuningSupported OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the XFP tuning support:
Bit1: wavelenght (Tunable DWDM - selection in 50 pm steps)
Bit2: frequency (Tunable DWDM - selection by channel number)
For exmaple the value 0 means no support, and 3 means both."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 49 }
sfpConfigXfpDesiredChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of channel number, which is an integer 1 to N (N=Number of Channels)."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 50 }
sfpConfigXfpDesiredWl OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of Wavelength setpoint (in units of 50 picometers)."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 51 }
sfpConfigXfpWlError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Monitor of Current Wavelength Error(in units of 5 picometers)."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 52 }
sfpConfigXfpDesiredFreq OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of channel number, which is an integer to N (N=Number of Channels)."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 53 }
sfpConfigXfpFreqError OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Frequency error reported in 16 bit signed integer with LSB=0.1 GHz."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 54 }
sfpConfigXfpDitherSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Tx Dither Supported."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 55 }
sfpConfigXfpDitherAdmin OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- enable
down(2) -- disable
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the dithering function."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 56 }
sfpConfigXfpCapFreqFirstThz OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lasers First Frequency (THz) capability."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 57 }
sfpConfigXfpCapFreqFirst10Ghz OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lasers First Frequency (GHz*10) capability.
This value should be added to sfpConfigXfpCapFreqFirstThz."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 58 }
sfpConfigXfpCapFreqLastThz OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lasers Last Frequency (THz) capability."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 59 }
sfpConfigXfpCapFreqLast10Ghz OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lasers Last Frequency (GHz*10) capability.
This value should be added to sfpConfigXfpCapFreqLastThz."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 60 }
sfpConfigXfpCapMaxSpacing10Ghz OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lasers maximum supported grid spacing (GHz*10) capability."
REFERENCE "SFP-8477."
::= { sfpConfigEntry 61 }
sfpConfigXfpCalibrationSupported OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibarion Supported."
::= { sfpConfigEntry 62 }
sfpConfigXfpCalibrationEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the calibration process.
Changing the value to Enable when a signal exist invokes an immidiate calibration process.
Changing the value to Disable returns the calibration values to defaults."
::= { sfpConfigEntry 63 }
--
-- CFP Information
--
sfpConfigCfpExtId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Extended Identifier bit fields:
Bits 7-6 - Power Class:
00b: Power Class 1 Module (? 8 W max),
01b: Power Class 2 Module (?16 W max),
10b: Power Class 3 Module (? 24 W max),
11b: Power Class 4 Module (? 32 W max).
Bits 5-4 Lane Ratio:
00b: Network lane : Host lane = 1 : n (Mux type),
01b: Network lane : Host lane = n : m (Gear Box type),
10b: Network lane : Host lane = n : n (Parallel type),
11b: Reserved
Bits 3-1 WDM Type:
000b: Non-WDM,
001b: CWDM,
010b: LANWDM,
011b: DWDM on 200G-grid,
100b: DWDM on 100G-grid,
101b: DWDM on 50G-grid,
110b: DWDM on 25G-grid,
111b: Other type WDM
Bit 0 CLEI Presence:
0: No CLEI code present,
1: CLEI code present"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 70 }
sfpConfigCfpConnectorType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Connector Type Code:
00h: Undefined,
01h : SC,
07h : LC,
08h : MT-RJ,
09h : MPO,
Other Codes : Reserved"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 71 }
sfpConfigCfpEthernetCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet Application Code.
00h: Undefined type,
01h: 100GE SMF 10km, 100GE-LR4,
02h: 100GE SMF 40km, 100GE-ER4,
03h: 100GE MMF 100m OM3, 100GE-SR10,
04h: For future use,
05h: 40GE SMF 10km, 40GE-LR4,
07h: 40GE MMF 100m OM3, 40GE-SR4,
For future use:
100G G.959.1 OTU4
40G G.693 SDH
40G G.693 OTU3
40G G.695 SDH
40G G.695 OTU3,
0Dh: 40GE-CR4 Copper
0Eh: 100GE-CR10 Copper,
0Fh: 40G BASE-FR,
10h~FFh: Reserved."
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 72 }
sfpConfigCfpFcCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fiber Channel Application Code: Undefined"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 73 }
sfpConfigCfpCopperCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Copper Link Application Code: Undefined"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 74 }
sfpConfigCfpSonetCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SONET/SDH Application Code:
00h: Undefined type,
01h: VSR2000-3R2,
02h: VSR2000-3R3,
03h: VSR2000-3R5,
04h ~ 0FFh: Reserved"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 75 }
sfpConfigCfpOtnCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OTN Application Code:
0h: Undefined type,
01h: VSR2000-3R2F,
02h: VSR2000-3R3F,
03h: VSR2000-3R5F,
04h: VSR2000-3L2F,
05h: VSR2000-3L3F,
06h: VSR2000-3L5F,
07h: C4S1-2D1 (OTL3.4),
08h: 4I1-9D1F (OTL4.4),
09h ~ 0FFh: Reserved"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 76 }
sfpConfigCfpSupportedRates OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Additional Capable Rates Supported Bitmap:
Bits 7-5 - Reserved
Bit 4 - 111.8 Gbps
Bit 3 - 103.125 Gbps
Bit 2 - 41.25 Gbps
Bit 1 - 43 Gbps
Bit 0 - 39.8 Gbps"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 77 }
sfpConfigCfpSupportedLanes OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Lanes Supported:
Bits 7-4 - Number of Network Lanes
The value of 0 represents 16 network lanes supported.
The values of 1 through 15 represent the actual number of network lanes supported
Bits 3-0 - Number of Host Lanes
The value of 0 represents 16 network lanes supported.
The values of 1 through 15 represent the actual number of network lanes supported"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 78 }
sfpConfigCfpMediaProperties OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Media Properties bit fields:
Bits 7 - 6 Media Type:
00b: SMF ,
01b: MMF (OM3),
10b: Reserved,
11b: Copper
Bit 5 - Directionality:
0: Normal,
1: BiDi
Bit 4 Optical Multiplexing and De-multiplexing:
0: Without optical MUX/DEMUX,
1: With optical MUX/DEMUX
Bits 3 - 0 ctive Fiber per Connector:
A 4-bit unsigned number representing number of active fibers for TX and RX per connector:
0: 16 TX Lanes and 16 RX Lanes,
1: 1 TX Lane and 1 RX Lane,
4: 4 TX Lanes and 4 RX Lanes,
10: 10 TX Lanes and 10 RX Lanes,
12: 12 TX Lanes and 12 RX Lanes"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 79 }
sfpConfigCfpMaxNetworkLaneRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Network Lane Bit Rate: 8-bit value x 0.2 Gbps"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 80 }
sfpConfigCfpMaxHostLaneRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Host Lane Bit Rate: 8-bit value x 0.2 Gbps"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 81 }
sfpConfigCfpMaxSmFiberLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Single Mode Optical Fiber Length:
8-bit value x 1 km for single mode fiber length"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 82 }
sfpConfigCfpMaxMmFiberLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Multi-Mode Optical Fiber Length:
8-bit value x 10 m for multi-mode fiber length"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 83 }
sfpConfigCfpMaxCopperCableLength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Copper Cable Length:
8-bit value x 1 m for copper cable length"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 84 }
sfpConfigCfpMinWavelenPerActive OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum Wavelength per Active Fiber:
16-bit unsigned value x 0.025 nm.
(MSB is at 8012h, LSB is at 8013h)"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 85 }
sfpConfigCfpMaxWavelenPerActive OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Wavelength per Active Fiber:
16-bit unsigned value x 0.025 nm.
(MSB is at 8014h, LSB is at 8015h)"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 86 }
sfpConfigCfpMaxLenOpticalWidth OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum per Lane Optical Width:
Guaranteed range of laser wavelength.
16-bit unsigned value x 1 pm.
(MSB is at 8016h, LSB is at 8017h)"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 87 }
sfpConfigCfpSpacing OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The spacing between two lanes:
0- unknown spacing
1 - 100G spacing
2 - 50G spacing
3- 25G spacing"
REFERENCE "CFP MSA 1.4"
::= { sfpConfigEntry 88 }
--
-- QSFP+ Information
--
sfpConfigQsfppEthernetCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum per Lane Optical Width:
Guaranteed range of laser wavelength.
16-bit unsigned value x 1 pm.
(MSB is at 8016h, LSB is at 8017h)"
REFERENCE "QSFP+ SFF-8436"
::= { sfpConfigEntry 100 }
sfpConfigQsfppSonetCode OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The spacing between two lanes:
0- unknown spacing
1 - 100G spacing
2 - 50G spacing
3- 25G spacing"
REFERENCE "QSFP+ SFF-8436"
::= { sfpConfigEntry 101 }
--
-- CXP Information
--
sfpConfigCxpExtId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Extended Identifier (Byte 129):
Bits 7-5 - Power Class:
000: 0.25W max - Class 0
001: 1.0W max - Class 1
010: 1.5W max - Class 2
011: 2.5W max - Class 3
100: 4.0W max - Class 4
101: 6.0W max - Class 5
110: >6.0W - Class 6
111: Reserved
Bits 4 Tx CDR Presence:
1: Tx CDR provided
0: Otherwise
Bits 3 Rx CDR Presence:
1: Rx CDR provided;
0: Otherwise"
REFERENCE ""
::= { sfpConfigEntry 110 }
sfpConfigCxpConnectorType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Connector Type Code (Byte 130):
30h: Passive Copper Cable Assembly
31h: Active Copper Cable Assembly (ref. Byte 147)
32h: Active Optical Cable Assembly
33h: Optical Transceiver w/ optical connector"
REFERENCE ""
::= { sfpConfigEntry 111 }
sfpConfigCxpMaxSupportedRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max per-channel bit rate (Byte 134):
Max signal rate = binary value x 100 Mb/s"
REFERENCE ""
::= { sfpConfigEntry 112 }
sfpConfigCxpNominalWavelength OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wavelength/Attenuation (Bytes 135-136):
Optical: Nominal Laser Wavelength --
Wavelength in nm = value / 20): e.g. 42h 04h = 16,900, 16,900/20 = 845 nm
Copper: Nominal attenuation of cable either to the other end (passive) or to equalizer (active)
Byte 135:
Attenuation at 2.5 GHz in dB -
00h=no info
Byte 136:
Attenuation at 5 GHz in dB -
00h=no info"
REFERENCE ""
::= { sfpConfigEntry 113 }
sfpConfigCxpDeviceTech OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Device Technology (Byte 147):
Bits 7-4 (Device Technology):
0000: 850 nm VCSEL
0001:1310 nm VCSEL
0010:1550 nm VCSEL
0011: 1310 nm FP
0100:1310 nm DFB
0101:1550 nm DFB
0110: 1310 nm EML
0111: 1550 nm EML
1000: Copper or others
11001: 1490 nm DFB
1010: Copper cable un-equalized
1011: Copper cable passive equalized
1100: Copper cable near & far end active equalizers
1101: Copper cable, far end active equalizer
1110: copper cable, near end active equalizer
1111: Reserved
Bit 3 (Wavelength Control):
0: No control
1: Active wavelength control
Bit 2 (Transmitter cooling):
0: Uncooled transmitter
1: Cooled transmitter
Bit 1 (Optical Detector):
0: P-I-N Detector
1: APD detector
Bit 0 (Optical Tunability):
0: Transmitter not tunable
1:Transmitter tunable"
REFERENCE ""
::= { sfpConfigEntry 114 }
--
-- Coherent Information
--
sfpConfigCohRxDesiredChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of RX channel number, which is an integer 1 to N (N=Number of Channels)."
REFERENCE "CFP MSA"
::= { sfpConfigEntry 115 }
sfpConfigCohRxDesiredWl OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of RX Wavelength setpoint (in units of 50 picometers)."
REFERENCE "CFP MSA"
::= { sfpConfigEntry 116 }
sfpConfigCohRxDesiredFreq OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User input of channel number, which is an integer to N (N=Number of Channels)."
REFERENCE "CFP MSA"
::= { sfpConfigEntry 117 }
sfpConfigCohCurrentCD OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Chromatic Dispersion counter. Units are in ps/nm"
REFERENCE "CFP MSA"
::= { sfpConfigEntry 118 }
sfpConfigCohCurrentOSNR OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current SNR. Units are in 0.1dB"
REFERENCE "CFP MSA"
::= { sfpConfigEntry 119 }
sfpConfigCohAverageOSNR OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average SNR over PM interval. Units are in 0.1dB"
REFERENCE "CFP MSA"
::= { sfpConfigEntry 120 }
sfpConfigCohMaxCD OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximal Chromatic Dispersion counter. Units are in ps/nm"
REFERENCE "CFP MSA"
::= { sfpConfigEntry 121 }
sfpConfigNyquist OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Nyquist - True (ON) or False (OFF). Default is OFF"
::= { sfpConfigEntry 122 }
-- ----------------------------------------------------
--
-- The SFP Diagnostic Table
--
-- ----------------------------------------------------
sfpDiagTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SFP diagnostic table.
The table defines the status and control of the alarms and warnings
of the SFP-1310 and the DWDM SFP-15xy modules."
::= { sfpDiag 1 }
sfpDiagEntry OBJECT-TYPE
SYNTAX SfpDiagEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SFP diagnostic table.
The index to this table is the same as the ifIndex of the SFP.
The SFP Diagnostic Table contain and entry for each
SFP module."
INDEX { sfpDiagInterface }
::= { sfpDiagTable 1 }
SfpDiagEntry ::=
SEQUENCE {
sfpDiagInterface InterfaceIndex,
-- Alarms and Warnings Thresholds
sfpDiagHighTempAlmThreshold INTEGER,
sfpDiagLowTempAlmThreshold INTEGER,
sfpDiagHighTempWrnThreshold INTEGER,
sfpDiagLowTempWrnThreshold INTEGER,
sfpDiagHighVoltAlmThreshold INTEGER,
sfpDiagLowVoltAlmThreshold INTEGER,
sfpDiagHighVoltWrnThreshold INTEGER,
sfpDiagLowVoltWrnThreshold INTEGER,
sfpDiagHighTxBiasAlmThreshold INTEGER,
sfpDiagLowTxBiasAlmThreshold INTEGER,
sfpDiagHighTxBiasWrnThreshold INTEGER,
sfpDiagLowTxBiasWrnThreshold INTEGER,
sfpDiagHighTxPowerAlmThreshold INTEGER,
sfpDiagLowTxPowerAlmThreshold INTEGER,
sfpDiagHighTxPowerWrnThreshold INTEGER,
sfpDiagLowTxPowerWrnThreshold INTEGER,
sfpDiagHighRxPowerAlmThreshold INTEGER,
sfpDiagLowRxPowerAlmThreshold INTEGER,
sfpDiagHighRxPowerWrnThreshold INTEGER,
sfpDiagLowRxPowerWrnThreshold INTEGER,
sfpDiagHighLaserTempAlmThreshold INTEGER, -- 15xy
sfpDiagLowLaserTempAlmThreshold INTEGER, -- 15xy
sfpDiagHighLaserTempWrnThreshold INTEGER, -- 15xy
sfpDiagLowLaserTempWrnThreshold INTEGER, -- 15xy
sfpDiagHighWaveLenAlmThreshold INTEGER, -- 15xy
sfpDiagLowWaveLenAlmThreshold INTEGER, -- 15xy
sfpDiagHighWaveLenWrnThreshold INTEGER, -- 15xy
sfpDiagLowWaveLenWrnThreshold INTEGER, -- 15xy
sfpDiagHighTecCurrAlmThreshold INTEGER, -- 15xy
sfpDiagLowTecCurrAlmThreshold INTEGER, -- 15xy
sfpDiagHighTecCurrWrnThreshold INTEGER, -- 15xy
sfpDiagLowTecCurrWrnThreshold INTEGER, -- 15xy
-- Measured Values
sfpDiagModuleTemperature INTEGER,
sfpDiagSupplyVoltage INTEGER,
sfpDiagTxBias INTEGER,
sfpDiagTxOutputPower INTEGER,
sfpDiagRxInputPower INTEGER,
sfpDiagRxLaserTemperature INTEGER, -- 15xy
sfpDiagRxMeasuredWavelength INTEGER, -- 15xy
sfpDiagRxTecCurrent INTEGER, -- 15xy
-- Status and Control
sfpDiagAlarms INTEGER,
sfpDiagAlarmsMask INTEGER,
sfpDiagWarnings INTEGER,
sfpDiagWarningsMask INTEGER,
sfpDiagConfLowRxPowerAlmThreshold INTEGER,
sfpDiagRxInputPowerFloat Float32TC,
-- CXP
sfpDiagCxpTxTemp INTEGER,
sfpDiagCxpHighTxTempAlmThreshold INTEGER,
sfpDiagCxpLowTxTempAlmThreshold INTEGER,
sfpDiagCxpRxTemp INTEGER,
sfpDiagCxpHighRxTempAlmThreshold INTEGER,
sfpDiagCxpLowRxTempAlmThreshold INTEGER,
-- OTDR
sfpDiagOtdrFiberCutRange INTEGER,
sfpDiagModuleTemperatureCelsius INTEGER
}
sfpDiagInterface OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interface Index of the SFP (type=196)."
::= { sfpDiagEntry 1 }
-- Alarms and Warnings Thresholds
sfpDiagHighTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high temperature alarm. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 2 }
sfpDiagLowTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low temperature alarm. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius.."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 3 }
sfpDiagHighTempWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high temperature warning. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 4 }
sfpDiagLowTempWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low temperature warning. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius.."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 5 }
sfpDiagHighVoltAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high voltage alarm. The value 0
means 0 Volts. An increment on one is equivalent to 100 uVolt,
yielding a total range of +6.55 Volts."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 6 }
sfpDiagLowVoltAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low voltage alarm. The value 0
means 0 Volts. An increment on one is equivalent to 100 uVolt,
yielding a total range of +6.55 Volts."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 7 }
sfpDiagHighVoltWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high voltage warning. The value 0
means 0 Volts. An increment on one is equivalent to 100 uVolt,
yielding a total range of +6.55 Volts."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 8 }
sfpDiagLowVoltWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low voltage warning. The value 0
means 0 Volts. An increment on one is equivalent to 100 uVolt,
yielding a total range of +6.55 Volts."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 9 }
sfpDiagHighTxBiasAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high voltage alarm. The value 0
means 0 Volt. An increment on one is equivalent to 2 uA,
yielding a total range of 0 to 131 mA."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 10 }
sfpDiagLowTxBiasAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low voltage alarm. The value 0
means 0 Volts. An increment on one is equivalent to 2 uA,
yielding a total range of 0 to 131 mA."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 11 }
sfpDiagHighTxBiasWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high voltage warning. The value 0
means 0 Volt. An increment on one is equivalent to 2 uA,
yielding a total range of 0 to 131 mA."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 12 }
sfpDiagLowTxBiasWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low voltage warning. The value 0
means 0 Volts. An increment on one is equivalent to 2 uA,
yielding a total range of 0 to 131 mA."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 13 }
sfpDiagHighTxPowerAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high TX power alarm. The value 0
means 0 Volt. An increment on one is equivalent to 1 uW,
yielding a total range of 0 to 65.535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 14 }
sfpDiagLowTxPowerAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low TX power alarm. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 65.535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 15 }
sfpDiagHighTxPowerWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high TX power warning. The value 0
means 0 Volt. An increment on one is equivalent to 1 uW,
yielding a total range of 0 to 65.535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 16 }
sfpDiagLowTxPowerWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low TX power warning. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 65.535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 17 }
sfpDiagHighRxPowerAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high RX power alarm. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 6.5535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 18 }
sfpDiagLowRxPowerAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low RX power alarm. The value 0
means 0 Volt. An increment on one is equivalent to 1 uW,
yielding a total range of 0 to 6.5535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 19 }
sfpDiagHighRxPowerWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for high RX power warning. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 6.5535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 20 }
sfpDiagLowRxPowerWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The threshold value for low RX power warning. The value 0
means 0 Volt. An increment on one is equivalent to 1 uW,
yielding a total range of 0 to 6.5535 mW."
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
::= { sfpDiagEntry 21 }
sfpDiagHighLaserTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write -- 15xy
STATUS current
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for high laser temperature alarm. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 22 }
sfpDiagLowLaserTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for low laser temperature alarm. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 23 }
sfpDiagHighLaserTempWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for high laser temperature warning. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 24 }
sfpDiagLowLaserTempWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write -- 15xy
STATUS current
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for low laser temperature warning. The value 0
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 25 }
sfpDiagHighWaveLenAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for high laser temperature alarm.
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
of 0.01nm."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 26 }
sfpDiagLowWaveLenAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for low laser temperature alarm.
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
of 0.01nm."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 27 }
sfpDiagHighWaveLenWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for high laser temperature warning.
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
of 0.01nm."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 28 }
sfpDiagLowWaveLenWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The threshold value for low laser temperature warning.
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
of 0.01nm."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 29 }
sfpDiagHighTecCurrAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"The threshold value for high TEC current alarm.
The reported TEC current is defined as a positive number for cooling and
a negative number for heating starting at -3276.8.
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 30 }
sfpDiagLowTecCurrAlmThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"The threshold value for low TEC current alarm.
The reported TEC current is defined as a positive number for cooling and
a negative number for heating starting at -3276.8.
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 31 }
sfpDiagHighTecCurrWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"The threshold value for high TEC current warning.
The reported TEC current is defined as a positive number for cooling and
a negative number for heating starting at -3276.8.
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 32 }
sfpDiagLowTecCurrWrnThreshold OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current -- 15xy
DESCRIPTION
"The threshold value for low TEC current warning.
The reported TEC current is defined as a positive number for cooling and
a negative number for heating starting at -3276.8.
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
REFERENCE "DWDM MSA Table 2.3.19."
::= { sfpDiagEntry 33 }
-- Diagnostics Measured Values
sfpDiagModuleTemperature OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured module temperature. The value 0 means -128 Celsuis.
An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius.
Temperature accuracy is vendor specific but must be better than <20>3
degrees Celsius over specified operating temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 34 }
sfpDiagSupplyVoltage OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured supply voltage in transceiver. The value 0 means 0 Volts.
An increment on one is equivalent to 100 uVolt,
yielding a total range of +6.55 Volts.
Accuracy is vendor specific but must be better than <20>3% of the
manufacturer<65>s nominal value over specified operating temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 35 }
sfpDiagTxBias OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured TX Bias Current. The value 0
means 0 Volt. An increment on one is equivalent to 2 uA,
yielding a total range of 0 to 131 mA.
Accuracy is vendor specific but must be better than <20>3dB over specified
temperature and voltage. Data is not valid when the transmitter is disabled."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 36 }
sfpDiagTxOutputPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured TX output power. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 6.5535 mW.
For the vendor specified wavelength, accuracy shall be better than <20>3dB
over specified temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 37 }
sfpDiagRxInputPower OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured RX input power. The value 0
means 0 Watts. An increment on one is equivalent to 0.1 uW,
yielding a total range of 0 to 6.5535 mW.
For the vendor specified wavelength, accuracy shall be better than <20>3dB
over specified temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 38 }
sfpDiagRxLaserTemperature OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"Measured Laser Temperature.
For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The value 0 means -128 Celsuis. An increment on one is equivalent
to 1/256 degree, yielding a total range of -128 to +128 Celsius.
Temperature accuracy is vendor specific but must be better than <20> 0.2
degrees Celsius over specified operating temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21."
::= { sfpDiagEntry 39 }
sfpDiagRxMeasuredWavelength OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"Measured Laser Wavelength.
For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The wavelength is defined as:
Wavelength = 1000nm + 0.01nm * 16 bit value.
Thus, the reportable wavelength range is 1000.00 <20> 1655.35nm with a
resolution of 0.01nm."
REFERENCE "DWDM MSA Table 2.3.21."
::= { sfpDiagEntry 40 }
sfpDiagRxTecCurrent OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current -- 15xy
DESCRIPTION
"Measured Laser Temperature or Wavelength.
For DWDM applications, the diagnostic interface report either laser
wavelength or temperature, with a given module<6C>s reporting defined
by bit 1 of the object sfpConfigOptionalWdm.
The reported TEC current is defined as a positive number for cooling and
a negative number for heating starting at -3276.8.
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7,
The accuracy of the TEC current monitor is vendor specific but must be
better than <20>15% of the maximum TEC current as stored in the TEC Current
High Alarm Threshold"
REFERENCE "DWDM MSA Table 2.3.21."
::= { sfpDiagEntry 41 }
-- Status and Control
sfpDiagAlarms OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Alarms of the SFP module.
The sfpDiagAlarms is a bit map represented as a sum, therefore,
it can represent multiple failures (alarms) simultaneously.
The various bit positions are:
0 Temp High Alarm Set when internal temperature exceeds high alarm level.
1 Temp Low Alarm Set when internal temperature is below low alarm level.
2 Vcc High Alarm Set when internal supply voltage exceeds high alarm level.
3 Vcc Low Alarm Set when internal supply voltage is below low alarm level.
4 TX Bias High Alarm Set when TX Bias current exceeds high alarm level.
5 TX Bias Low Alarm Set when TX Bias current is below low alarm level.
6 TX Power High Alarm Set when TX output power exceeds high alarm level.
7 TX Power Low Alarm Set when TX output power is below low alarm level.
8 RX Power High Alarm Set when Received Power exceeds high alarm level.
9 RX Power Low Alarm Set when Received Power is below low alarm level.
10 (15xy) Laser T/W High Alarm Set when laser temperature or wavelength exceeds high alarm level.
11 (15xy) Laser T/W Low Alarm Set when laser temperature or wavelength is below low alarm level.
12 (15xy) TEC Current High Alarm Set when TEC current exceeds high alarm level.
13 (15xy) TEC Current Low Alarm Set when TEC current is below low alarm level.
14 Retimer Loss Of Lock
15 Removed SFP
16 Rx Signal Detect alarm
17 Laser End of Life
18 Laser Tx Failure Indication."
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
::= { sfpDiagEntry 42 }
sfpDiagAlarmsMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Masking of the Alarms of the SFP module.
The sfpDiagAlarmsMask is a bit map. Any of the alarm and warning flags can
be masked by writing a 1 to the corresponding bits.
The various bit positions are:
0 Temp High Wanring Set when internal temperature exceeds high warning level.
1 Temp Low Wanring Set when internal temperature is below low warning level.
2 Vcc High Wanring Set when internal supply voltage exceeds high warning level.
3 Vcc Low Wanring Set when internal supply voltage is below low warning level.
4 TX Bias High Wanring Set when TX Bias current exceeds high warning level.
5 TX Bias Low Wanring Set when TX Bias current is below low warning level.
6 TX Power High Wanring Set when TX output power exceeds high warning level.
7 TX Power Low Wanring Set when TX output power is below low warning level.
8 RX Power High Wanring Set when Received Power exceeds high warning level.
9 RX Power Low Wanring Set when Received Power is below low warning level.
10 (15xy) Laser T/W High Wanring Set when laser temperature or wavelength exceeds high warning level.
11 (15xy) Laser T/W Low Wanring Set when laser temperature or wavelength is below low warning level.
12 (15xy) TEC Current High Wanring Set when TEC current exceeds high warning level.
13 (15xy) TEC Current Low Wanring Set when TEC current is below low warning level."
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
::= { sfpDiagEntry 43 }
sfpDiagWarnings OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Warnings of the SFP module.
The sfpDiagWarnings is a bit map represented as a sum, therefore,
it can represent multiple failures (alarms) simultaneously.
The various bit positions are:
0 Temp High Warning Set when internal temperature exceeds high warning level.
1 Temp Low Warning Set when internal temperature is below low warning level.
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
6 TX Power High Warning Set when TX output power exceeds high warning level.
7 TX Power Low Warning Set when TX output power is below low warning level.
8 RX Power High Warning Set when Received Power exceeds high warning level.
9 RX Power Low Warning Set when Received Power is below low warning level.
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
12 TEC Current High Warning Set when TEC current exceeds high warning level.
13 TEC Current Low Warning Set when TEC current is below low warning level."
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
::= { sfpDiagEntry 44 }
sfpDiagWarningsMask OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Masking of the Warnings of the SFP module.
The sfpDiagWarningsMask is a bit map. Any of the alarm and warning flags can
be masked by writing a 1 to the corresponding bits.
The various bit positions are:
0 Temp High Warning Set when internal temperature exceeds high warning level.
1 Temp Low Warning Set when internal temperature is below low warning level.
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
6 TX Power High Warning Set when TX output power exceeds high warning level.
7 TX Power Low Warning Set when TX output power is below low warning level.
8 RX Power High Warning Set when Received Power exceeds high warning level.
9 RX Power Low Warning Set when Received Power is below low warning level.
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
12 TEC Current High Warning Set when TEC current exceeds high warning level.
13 TEC Current Low Warning Set when TEC current is below low warning level."
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
::= { sfpDiagEntry 45 }
sfpDiagConfLowRxPowerAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configured threshold value for low RX power alarm.
Changing this value doen't affect the SFP and is implemented by software.
The threshold level specified in 0.1 dBm units.
The range starts with -50.0 dBm."
::= { sfpDiagEntry 46 }
sfpDiagRxInputPowerFloat OBJECT-TYPE
SYNTAX Float32TC
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured RX input power sepcified in floating units.
This object is used for power < -40dBm that can be achieved with SFP external calibration.
When not used this value is 0 and sfpDiagRxInputPower should be used."
::= { sfpDiagEntry 47 }
--
-- CXP
--
sfpDiagCxpTxTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured Tx temperature. The value 0 means -128 Celsius.
An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 22-23 (Tx Lower Page)"
::= { sfpDiagEntry 50 }
sfpDiagCxpHighTxTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value for high Tx temperature alarm.
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 128-129 (Tx Upper Page)"
::= { sfpDiagEntry 51 }
sfpDiagCxpLowTxTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value for low Tx temperature alarm.
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 130-131 (Tx Upper Page)"
::= { sfpDiagEntry 52 }
sfpDiagCxpRxTemp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured Rx temperature. The value 0 means -128 Celsius.
An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 22-23 (Rx Lower Page)"
::= { sfpDiagEntry 53 }
sfpDiagCxpHighRxTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value for high Rx temperature alarm.
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 128-129 (Rx Upper Page)"
::= { sfpDiagEntry 54 }
sfpDiagCxpLowRxTempAlmThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The threshold value for low Rx temperature alarm.
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
yielding a total range of -128 to +128 Celsius
For CXP Addr 130-131 (Rx Upper Page)"
::= { sfpDiagEntry 55 }
sfpDiagOtdrFiberCutRange OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OTDR calculated range to the fiber cut"
::= { sfpDiagEntry 56 }
sfpDiagModuleTemperatureCelsius OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Internally measured module temperature, while degress in Celsuis.
Total range of -128 to +128 Celsius.
Temperature accuracy is vendor specific but must be better than <20>3
degrees Celsius over specified operating temperature and voltage."
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
::= { sfpDiagEntry 57 }
-- ----------------------------------------------------
--
-- The SFP Traps
--
-- ----------------------------------------------------
sfpConfigChangeTrap NOTIFICATION-TYPE
OBJECTS { sfpConfigInterface }
STATUS current
DESCRIPTION
"A sfpTrapsChangeTrap trap is sent when the
content of an instance sfpConfigEntry changes. It
can be utilized by an NMS to trigger polls."
::= { sfpTraps 1 }
END