2592 lines
88 KiB
Plaintext
2592 lines
88 KiB
Plaintext
-- *****************************************************************
|
||
-- SFP MIB
|
||
-- *****************************************************************
|
||
|
||
SL-SFP-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY, OBJECT-TYPE,
|
||
NOTIFICATION-TYPE, Integer32, TimeTicks
|
||
FROM SNMPv2-SMI
|
||
Float32TC, Float64TC, Float128TC FROM FLOAT-TC-MIB
|
||
DisplayString, TruthValue,
|
||
TimeStamp FROM SNMPv2-TC
|
||
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
||
MODULE-COMPLIANCE, OBJECT-GROUP,
|
||
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
||
InterfaceIndex FROM IF-MIB
|
||
PerfCurrentCount, PerfIntervalCount,
|
||
PerfTotalCount FROM PerfHist-TC-MIB
|
||
CleiCode FROM SL-ENTITY-MIB
|
||
sitelight FROM SL-NE-MIB;
|
||
|
||
slSfp MODULE-IDENTITY
|
||
LAST-UPDATED "200501250000Z"
|
||
ORGANIZATION "PacketLight Networks Ltd."
|
||
CONTACT-INFO
|
||
"Omri_Viner@PacketLight.com"
|
||
DESCRIPTION
|
||
"This MIB module describes the SFP Modules"
|
||
::= { sitelight 10 }
|
||
|
||
-- The SFP MIB consists of the following groups:
|
||
-- SFP Configuration Table
|
||
-- SFP Diagnostic Table
|
||
-- SFP Traps
|
||
|
||
sfpConf OBJECT IDENTIFIER ::= { slSfp 1 }
|
||
sfpDiag OBJECT IDENTIFIER ::= { slSfp 2 }
|
||
sfpTraps OBJECT IDENTIFIER ::= { slSfp 3 }
|
||
sfpTune OBJECT IDENTIFIER ::= { slSfp 4 }
|
||
|
||
-- Textual Conventions
|
||
|
||
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Configuration Table
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpConfigTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SfpConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SFP configuration table.
|
||
The table defines the configuration of the SFP-1310 and
|
||
the SFP-WDM modules."
|
||
::= { sfpConf 1 }
|
||
|
||
sfpConfigEntry OBJECT-TYPE
|
||
SYNTAX SfpConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the SFP configuration table.
|
||
The index to this table is the same as the ifIndex of the SFP.
|
||
The SFP Config Table contain and entry for each
|
||
module of a type SFP."
|
||
INDEX { sfpConfigInterface }
|
||
::= { sfpConfigTable 1 }
|
||
|
||
SfpConfigEntry ::=
|
||
SEQUENCE {
|
||
sfpConfigInterface InterfaceIndex,
|
||
|
||
-- Base ID Fields
|
||
sfpConfigXcvrId INTEGER,
|
||
sfpConfig1310ExtXcvrId INTEGER, -- 1310
|
||
sfpConfigWdmExtXcvrId INTEGER, -- 15xy
|
||
sfpConfigConnectorCode INTEGER,
|
||
sfpConfigInfibandCompliance INTEGER,
|
||
sfpConfigEsconCompliance INTEGER,
|
||
sfpConfigSonetCompliance INTEGER,
|
||
sfpConfigGbeCompliance INTEGER,
|
||
sfpConfigFcCompliance INTEGER,
|
||
sfpConfigEncodingCode INTEGER,
|
||
sfpConfigNominalBitRate INTEGER,
|
||
sfpConfigLength9mKm INTEGER,
|
||
sfpConfigLength9m100m INTEGER, -- 1310
|
||
sfpConfigLength50m10m INTEGER, -- 1310
|
||
sfpConfigLength62m10m INTEGER, -- 1310
|
||
sfpConfigLengthCopper1m INTEGER, -- 1310
|
||
sfpConfigMaxTemp INTEGER, -- 15xy
|
||
sfpConfigMinTemp INTEGER, -- 15xy
|
||
sfpConfigMaxSupplyCurrent INTEGER, -- 15xy
|
||
sfpConfigChannelSpacing INTEGER, -- 15xy
|
||
sfpConfigVendorName SnmpAdminString,
|
||
sfpConfigOptionalWdm INTEGER, -- 15xy
|
||
sfpConfigVendorOUI INTEGER,
|
||
sfpConfigVendorPN SnmpAdminString,
|
||
sfpConfigVendorRev SnmpAdminString,
|
||
sfpConfigWaveLength INTEGER, -- 15xy only
|
||
|
||
-- Extended ID Fields
|
||
sfpConfigExtendedOptions INTEGER,
|
||
sfpConfigMaxBitRate INTEGER,
|
||
sfpConfigMinBitRate INTEGER,
|
||
sfpConfigVendorSN SnmpAdminString,
|
||
sfpConfigDateCode SnmpAdminString,
|
||
sfpConfigDiagnosticMonitoring INTEGER,
|
||
sfpConfigEnhanceOptions INTEGER,
|
||
sfpConfig8472Compliance INTEGER,
|
||
|
||
sfpConfigTunableWaveLength INTEGER, -- 15xy
|
||
sfpConfigVoaControl INTEGER, -- 15xy
|
||
sfpConfigVdtControl INTEGER, -- 15xy
|
||
sfpConfigPilotToneModulation INTEGER, -- 15xy
|
||
|
||
-- Non standard Fields
|
||
sfpConfigCleiCode DisplayString,
|
||
|
||
-- XFP standard Fields
|
||
sfpConfigXfpExtXcvrId INTEGER,
|
||
sfpConfigXfpEncodingCode INTEGER,
|
||
sfpConfigXfpMinBitRate INTEGER,
|
||
sfpConfigXfpMaxBitRate INTEGER,
|
||
sfpConfig10GSonetCompliance INTEGER,
|
||
sfpConfig10GbeCompliance INTEGER,
|
||
sfpConfig10GFcCompliance INTEGER,
|
||
sfpConfigXfpDeviceTech INTEGER,
|
||
|
||
-- XFP SFP-8477 Extended Fields (Tuning and Dither)
|
||
sfpConfigXfpTuningSupported INTEGER,
|
||
sfpConfigXfpDesiredWl INTEGER,
|
||
sfpConfigXfpWlError INTEGER,
|
||
sfpConfigXfpDesiredChannel INTEGER,
|
||
sfpConfigXfpDesiredFreq INTEGER,
|
||
sfpConfigXfpFreqError INTEGER,
|
||
sfpConfigXfpDitherSupported TruthValue,
|
||
sfpConfigXfpDitherAdmin INTEGER,
|
||
sfpConfigXfpCapFreqFirstThz INTEGER,
|
||
sfpConfigXfpCapFreqFirst10Ghz INTEGER,
|
||
sfpConfigXfpCapFreqLastThz INTEGER,
|
||
sfpConfigXfpCapFreqLast10Ghz INTEGER,
|
||
sfpConfigXfpCapMaxSpacing10Ghz INTEGER,
|
||
sfpConfigXfpCalibrationSupported TruthValue,
|
||
sfpConfigXfpCalibrationEnabled TruthValue,
|
||
|
||
-- CFP MSA Rev 1.4
|
||
sfpConfigCfpExtId INTEGER,
|
||
sfpConfigCfpConnectorType INTEGER,
|
||
sfpConfigCfpEthernetCode INTEGER,
|
||
sfpConfigCfpFcCode INTEGER,
|
||
sfpConfigCfpCopperCode INTEGER,
|
||
sfpConfigCfpSonetCode INTEGER,
|
||
sfpConfigCfpOtnCode INTEGER,
|
||
sfpConfigCfpSupportedRates INTEGER,
|
||
sfpConfigCfpSupportedLanes INTEGER,
|
||
sfpConfigCfpMediaProperties INTEGER,
|
||
sfpConfigCfpMaxNetworkLaneRate INTEGER,
|
||
sfpConfigCfpMaxHostLaneRate INTEGER,
|
||
sfpConfigCfpMaxSmFiberLength INTEGER,
|
||
sfpConfigCfpMaxMmFiberLength INTEGER,
|
||
sfpConfigCfpMaxCopperCableLength INTEGER,
|
||
sfpConfigCfpMinWavelenPerActive INTEGER,
|
||
sfpConfigCfpMaxWavelenPerActive INTEGER,
|
||
sfpConfigCfpMaxLenOpticalWidth INTEGER,
|
||
sfpConfigCfpSpacing INTEGER,
|
||
|
||
-- QSFP+ SFF-8436
|
||
sfpConfigQsfppEthernetCode INTEGER,
|
||
sfpConfigQsfppSonetCode INTEGER,
|
||
|
||
-- CXP
|
||
sfpConfigCxpExtId INTEGER,
|
||
sfpConfigCxpConnectorType INTEGER,
|
||
sfpConfigCxpMaxSupportedRate INTEGER,
|
||
sfpConfigCxpNominalWavelength INTEGER,
|
||
sfpConfigCxpDeviceTech INTEGER,
|
||
|
||
-- Coherent
|
||
sfpConfigCohRxDesiredChannel INTEGER,
|
||
sfpConfigCohRxDesiredWl INTEGER,
|
||
sfpConfigCohRxDesiredFreq INTEGER,
|
||
sfpConfigCohCurrentCD INTEGER,
|
||
sfpConfigCohCurrentOSNR INTEGER,
|
||
sfpConfigCohAverageOSNR INTEGER,
|
||
sfpConfigCohMaxCD INTEGER,
|
||
|
||
-- DSP
|
||
sfpConfigNyquist TruthValue
|
||
}
|
||
|
||
sfpConfigInterface OBJECT-TYPE
|
||
SYNTAX InterfaceIndex
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Interface Index of the SFP (type=196)."
|
||
::= { sfpConfigEntry 1 }
|
||
|
||
-- Base ID Fields
|
||
|
||
sfpConfigXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknone(0), -- Unknown or unspecified
|
||
gbic(1), -- GBIC
|
||
module(2), -- Module/connector soldered to motherboard
|
||
sfp1310(3), -- 1310 SFP
|
||
xfp(6), -- XFP
|
||
sfpDwdm(11), -- DWDM SFP
|
||
qsfp(12), -- QSFP
|
||
qsfpPlus(13), -- QSFP+
|
||
cfp(14), -- CFP
|
||
cxp(15), -- CXP
|
||
coherent(16), -- Coherent
|
||
qsfp28(17), -- QSFP28
|
||
cfp2(20) -- CFP2
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The identifier value specifies the physical device described by the serial information.
|
||
This value shall be included in the serial data. The defined identifier values are:
|
||
00h - Unknown or unspecified
|
||
01h - GBIC
|
||
02h - Module/connector soldered to motherboard
|
||
03h - 1310 SFP
|
||
04-0Ah - Reserved for XFP and other platforms
|
||
0Bh - DWDM SFP
|
||
80-FFh - Vendor specific."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.2,
|
||
SFP-8472 Table 3.1 and 3.2"
|
||
::= { sfpConfigEntry 2 }
|
||
|
||
sfpConfig1310ExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
modDef0(0), -- GBIC definition is not specified or not compliant with a defined MOD_DEF
|
||
modDef1(1), -- GBIC is compliant with MOD_DEF 1
|
||
modDef2(2), -- GBIC is compliant with MOD_DEF 2
|
||
modDef3(3), -- GBIC is compliant with MOD_DEF 3
|
||
modDef4(4), -- GBIC/SFP function is defined by serial ID only
|
||
modDef5(5), -- GBIC is compliant with MOD_DEF 5
|
||
modDef6(6), -- GBIC is compliant with MOD_DEF 6
|
||
modDef7(7) -- GBIC is compliant with MOD_DEF 7
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"The extended identifier value provides additional information about the 1310 transceiver.
|
||
The defined identifier values are:
|
||
00h GBIC definition is not specified or the GBIC
|
||
definition is not compliant with a defined
|
||
MOD_DEF. See product specification for details.
|
||
01h GBIC is compliant with MOD_DEF 1
|
||
02h GBIC is compliant with MOD_DEF 2
|
||
03h GBIC is compliant with MOD_DEF 3
|
||
04h GBIC/SFP function is defined by serial ID only
|
||
05h GBIC is compliant with MOD_DEF 5
|
||
06h GBIC is compliant with MOD_DEF 6
|
||
07h GBIC is compliant with MOD_DEF 7
|
||
08-FFh Reserved"
|
||
REFERENCE "SFP-8472 Table 3.1 and 3.3"
|
||
::= { sfpConfigEntry 3 }
|
||
|
||
sfpConfigWdmExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field is used to distinguish between different types of DWDM transceivers and
|
||
different power and environmental classes. The defined identifier values are:
|
||
Bits 7..6: Reserved
|
||
Bits 5..4: Class of WDM
|
||
00: no WDM
|
||
01: CWDM
|
||
10: DWDM
|
||
Bits 3..2: Class of power
|
||
00: P<1W
|
||
01: [1W,1.5W]
|
||
10: P>1.5W
|
||
11: reserved
|
||
Bits 3..2: Class of temp
|
||
00: [-5, 70C]
|
||
01: [1W,1.5W]
|
||
10: reserved
|
||
11: Defined by Bytes 15 - 16."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.3"
|
||
::= { sfpConfigEntry 4 }
|
||
|
||
sfpConfigConnectorCode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
conUnknown(0), -- Unknown or unspecified
|
||
conSc(1), -- SC
|
||
conFcCopper1(2), -- Fibre Channel Style 1 copper connector
|
||
conFcCopper2(3), -- Fibre Channel Style 2 copper connector
|
||
conBncTnc(4), -- BNC/TNC
|
||
conFcCoaxial(5), -- Fibre Channel coaxial headers
|
||
conFiberJack(6), -- FiberJack
|
||
conLc(7), -- LC
|
||
conMtRj(8), -- MT-RJ
|
||
conMu(9), -- MU
|
||
comSg(10), -- SG
|
||
conOpticalPigtail(11), -- Optical pigtail
|
||
conHssdc2(32), -- HSSDC II
|
||
conCopperPigtail(33) -- Optical pigtail
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The identifier value specifies the physical device described by the serial information.
|
||
This value shall be included in the serial data. The defined identifier values are:
|
||
00h - Unknown or unspecified
|
||
01h - SC
|
||
02h - Fibre Channel Style 1 copper connector
|
||
03h - Fibre Channel Style 2 copper connector
|
||
04h - BNC/TNC
|
||
05h - Fibre Channel coaxial headers
|
||
06h - FiberJack
|
||
07h - LC
|
||
08h - MT-RJ
|
||
09h - MU
|
||
0Ah - SG
|
||
0Bh - Optical pigtail
|
||
0Ch - 1Fh - Reserved
|
||
20h - HSSDC II
|
||
21h - Copper Pigtail
|
||
22h - 7Fh - Reserved
|
||
80-FFh - Vendor specific."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.4,
|
||
SFP-8472 Table 3.1 and 3.4."
|
||
::= { sfpConfigEntry 5 }
|
||
|
||
sfpConfigInfibandCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the Infiband interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: 1X SX
|
||
Bits 1: 1X LX
|
||
Bits 2: 1X Copper Active
|
||
Bits 3: 1X Copper Passive."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5."
|
||
::= { sfpConfigEntry 6 }
|
||
|
||
sfpConfigEsconCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only -- 1310
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the ESCON interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: ESCON MMF, 1310nm LED
|
||
Bits 1: ESCON SMF, 1310nm Laser"
|
||
REFERENCE "SFP-8472 Table 3.1 and 3.5."
|
||
::= { sfpConfigEntry 7 }
|
||
|
||
sfpConfigSonetCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the SONET interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: SONET reach specifier bit 1
|
||
Bits 1: SONET reach specifier bit 2
|
||
Where:
|
||
00 speed OC-3/OC-12/OC-48 Short reach - SONET SR compliant
|
||
10 speed OC-3/OC-12/OC-48 Short reach - SONET SR-1 compliant
|
||
10 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-1 compliant
|
||
01 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-2 compliant
|
||
10 speed OC-3/OC-12/OC-48 Long reach - SONET LR-1 compliant
|
||
01 speed OC-3/OC-12/OC-48 Long reach - SONET LR-2 compliant
|
||
11 speed OC-3/OC-12/OC-48 Long reach - SONET LR-3 compliant
|
||
Bits 2: OC-48, single mode long reach
|
||
Bits 3: OC-48, single mode inter. reach
|
||
Bits 4: OC-48, multi-mode short reach
|
||
Bits 5: OC-12, single mode long reach
|
||
Bits 6: OC-12, single mode inter. reach
|
||
Bits 7: OC-12 multi-mode short reach
|
||
Bits 8: OC-3, single mode long reach
|
||
Bits 9: OC-3, single mode inter. reach
|
||
Bits 10: OC-3, multi-mode short reach."
|
||
REFERENCE "DWDM MSA Table 2.3.1, 2.3.5 and 2.3.5a,
|
||
SFP-8472 Table 3.1, 3.5 and 3.5a."
|
||
::= { sfpConfigEntry 8 }
|
||
|
||
sfpConfigGbeCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the Infiband interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: 1000BASE-T
|
||
Bits 1: 1000BASE-CX
|
||
Bits 2: 1000BASE-LX
|
||
Bits 3: 1000BASE-SX
|
||
Bits 4: 100BASE-LX/LX10 -- 1310
|
||
Bits 5: 100BASE-FX -- 1310
|
||
Bits 6: BASE-BX10 -- 1310
|
||
Bits 7: BASE-PX." -- 1310
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5"
|
||
::= { sfpConfigEntry 9 }
|
||
|
||
sfpConfigFcCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the FC interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
- Fibre Channel link length:
|
||
Bits 0: very long distance (V)
|
||
Bits 1: short distance (S)
|
||
Bits 2: intermediate distance (I)
|
||
Bits 3: long distance (L)
|
||
- Fibre Channel transmitter technology
|
||
Bits 4: Longwave laser (LC)
|
||
Bits 5: Electrical inter-enclosure (EL)
|
||
Bits 6: Electrical intra-enclosure (EL)
|
||
Bits 7: Shortwave laser w/o OFC (SN)
|
||
Bits 8: Shortwave laser w/ OFC (SL)
|
||
Bits 9: Longwave laser (LL)
|
||
Bits 10: Copper Active -- 1310
|
||
Bits 11: Copper Passive -- 1310
|
||
- Fibre Channel transmission media
|
||
Bits 12: Twin Axial Pair (TW)
|
||
Bits 13: Shielded Twisted Pair (TP)
|
||
Bits 14: Miniature Coax (MI)
|
||
Bits 15: Video Coax (TV)
|
||
Bits 16: Multi-mode, 62.5m (M6)
|
||
Bits 17: Multi-mode, 50 m (M5)
|
||
Bits 18: Single Mode (SM)
|
||
- Fibre Channel speed
|
||
Bits 19: 800 MB/Sec
|
||
Bits 20: 400 MB/Sec
|
||
Bits 21: 200 MB/Sec
|
||
Bits 22: 100 MB/Sec
|
||
Bits 23: 1200 MB/Sec
|
||
Bits 24: 1600 MB/Sec."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5"
|
||
::= { sfpConfigEntry 10 }
|
||
|
||
sfpConfigEncodingCode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
encUnspecified(0), -- Unspecified
|
||
enc8B10B(1), -- 8B10B
|
||
enc4B5B(2), -- 4B5B
|
||
encNrz(3), -- NRZ
|
||
encManchester(4), -- Manchester
|
||
encSonet(5), -- SONET Scrambled
|
||
enc64B66B(6) -- 64B/66B
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encoding value indicates the serial encoding mechanism that is the
|
||
nominal design target of the particular transceiver.
|
||
The value shall be contained in the serial data.
|
||
The defined encoding values are:
|
||
00h: Unspecified
|
||
01h: 8B10B
|
||
02h: 4B5B
|
||
03h: NRZ
|
||
04h: Manchester
|
||
05h: SONET Scrambled
|
||
06h -FFh: Reserved."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.6,
|
||
SFP-8472 Table 3.1 and 3.6"
|
||
::= { sfpConfigEntry 11 }
|
||
|
||
sfpConfigNominalBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The nominal bit rate (BR, nominal) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second.
|
||
The bit rate includes those bits necessary to encode and delimit the
|
||
signal as well as those bits carrying data information.
|
||
A value of 0 indicates that the bit rate is not specified and must be
|
||
determined from the transceiver technology.
|
||
The actual information transfer rate will depend on the encoding of the data,
|
||
as defined by the encoding value."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 12 }
|
||
|
||
sfpConfigLength9mKm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Addition to EEPROM data from original GBIC definition.
|
||
This value specifies the link length that is supported by the transceiver while
|
||
operating in compliance with the applicable standards using single mode fiber.
|
||
A value of zero means that the transceiver does not support single mode
|
||
fiber or that the length information must be determined from the transceiver
|
||
technology."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 13 }
|
||
|
||
sfpConfigLength9m100m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using
|
||
single mode fiber.
|
||
The value is in units of 100 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 25.4 km.
|
||
A value of zero means that the transceiver does not support single mode
|
||
fiber or that the length information must be determined from the transceiver
|
||
technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 14 }
|
||
|
||
sfpConfigLength50m10m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using 50 micron
|
||
multi-mode fiber.
|
||
The value is in units of 10 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 2.54 km.
|
||
A value of zero means that the transceiver does not support 50 micron
|
||
multimode fiber or that the length information must be determined from the
|
||
transceiver technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 15 }
|
||
|
||
sfpConfigLength62m10m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using 62.5 micron
|
||
multi-mode fiber.
|
||
The value is in units of 10 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 2.54 km.
|
||
A value of zero means that the transceiver does not support 50 micron
|
||
multimode fiber or that the length information must be determined from the
|
||
transceiver technology.
|
||
It is common for the transceiver to support both 50 micron and 62.5 micron
|
||
fiber."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 16 }
|
||
|
||
sfpConfigLengthCopper1m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using copper cable.
|
||
The value is in units of 1 meter. A value of 255 means that the transceiver
|
||
supports a link length greater than 254 meters.
|
||
A value of zero means that the transceiver does not support copper cables
|
||
or that the length information must be determined from the
|
||
transceiver technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 17 }
|
||
|
||
sfpConfigMaxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the maximum operating case temperature the module is
|
||
rated for. The maximum case temperature is encoded as a signed two<77>s
|
||
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
|
||
This field should be used even if a standard operating temperature class
|
||
is indicated in the Extended Indentifier Byte (Byte 1)."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 18 }
|
||
|
||
sfpConfigMinTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the minimum operating case temperature the module is
|
||
rated for. The maximum case temperature is encoded as a signed two<77>s
|
||
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
|
||
This field should be used even if a standard operating temperature class
|
||
is indicated in the Extended Indentifier Byte."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 19 }
|
||
|
||
sfpConfigMaxSupplyCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the maximum supply current the module will consume
|
||
under worst case conditions. The maximum current is the byte value * 4mA."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 20 }
|
||
|
||
sfpConfigChannelSpacing OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"In the case of SFP:
|
||
This bit field value identifies the densest channel spacing
|
||
the module is compatible with and the number of channels over which the
|
||
module may be tuned by user command.
|
||
If not tunable, the number of channels is entered as 1.
|
||
The bit fields are:
|
||
Bits 7..6: Channel Spacing
|
||
00: 200 GHz (DWDM)
|
||
01: 100 GHz (DWDM)
|
||
10: 50 Ghz (DWDM)
|
||
11: Reserved
|
||
Bits 5..0: Number of channels (1 <20> 63).
|
||
In the case of XFP:
|
||
The value of this field is equal to the guaranteed range of laser
|
||
wavelength (+/- value) from Nominal wavelength.
|
||
(Wavelength Tol. = value/200 in nm)"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.7. XFP INF-8077i Section 5.34."
|
||
::= { sfpConfigEntry 21 }
|
||
|
||
sfpConfigVendorName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor name is a 16 character field that contains ASCII characters,
|
||
left-aligned and padded on the right with ASCII spaces (20h).
|
||
The vendor name shall be the full name of the corporation,
|
||
a commonly accepted abbreviation of the name of the corporation,
|
||
the SCSI company code for the corporation, or the stock exchange code
|
||
for the corporation.
|
||
At least one of the vendor name or the vendor OUI fields shall contain
|
||
valid serial data."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 22 }
|
||
|
||
sfpConfigOptionalWdm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The bits in the option field shall specify the options implemented
|
||
in the transceiver. The following bits are defined:
|
||
Bits 7: Optional Interrupt Pin Functionality Supported (1 if supported)
|
||
Bits 6..4: Pilot Tone Functionality
|
||
000b: No Pilot Tone Functionality
|
||
001b: Pilot Tone Detection Only
|
||
010b: Pilot Tone Injection Only
|
||
011b: Pilot Tone Injection and Detection
|
||
100b: Enhanched Pilot Tone Functionality
|
||
101b-111b: Reserved
|
||
Bits 3: Variable Optical Attenuator Implemented (1 if implemented)
|
||
Bits 2: Extended Transmit Power Monitoring
|
||
0: Default (SFF-8472) TX Power Monitoring
|
||
1: Extended TX Power Monitoring (+18.2 dBm max)
|
||
Bits 1: Wavelength Monitor Type in A2 Byte 106-107
|
||
0: Monitor is Wavelength
|
||
1: Monitor is Laser Temperature
|
||
Bits 0: Variable Decision Threshold (1 if implemented)"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.8."
|
||
::= { sfpConfigEntry 23 }
|
||
|
||
sfpConfigVendorOUI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor organizationally unique identifier field (vendor OUI)
|
||
is a 3-byte field that contains the IEEE Company Identifier for the
|
||
vendor. A value of all zero in the 3-byte field indicates that
|
||
the Vendor OUI is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 24 }
|
||
|
||
sfpConfigVendorPN OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor part number (vendor PN) is a 16-byte field that contains
|
||
ASCII characters, left-aligned and padded on the right with ASCII
|
||
spaces (20h), defining the vendor part number or product name.
|
||
A value of all zero in the 16-byte field indicates that the
|
||
vendor PN is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 25 }
|
||
|
||
sfpConfigVendorRev OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor revision number (vendor rev) is a 4-byte field that
|
||
contains ASCII characters, left-aligned and padded on the right with
|
||
ASCII spaces (20h), defining the vendor<6F>s product revision number.
|
||
A value of all zero in the 4-byte field indicates that
|
||
the vendor PN is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 26 }
|
||
|
||
sfpConfigWaveLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"In the case of DWDM:
|
||
Nominal transmitter output wavelength in units of 0.01nm.
|
||
As an example, a wavelength of 1550.51nm would be encoded as: 155051.
|
||
In the case of 1310:
|
||
The laser wavelength is equal to the the integer value in nm with 00 at
|
||
the end.
|
||
As an example, a wavelength of 1310 would be encoded as: 131000."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 27 }
|
||
|
||
-- Extended ID Fields
|
||
|
||
sfpConfigExtendedOptions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specify the bitmap options implemented in the transceiver as described in.
|
||
The bits definition is:
|
||
5 RATE_SELECT is implemented
|
||
NOTE: Lack of implemention does not indicate lack of
|
||
simultaneous compliance with multiple standard rates.
|
||
Compliance with particular standards should be determined
|
||
from Transceiver Code.
|
||
4 TX_DISABLE is implemented and disables the serial output.
|
||
3 TX_FAULT signal implemented. (See SFP MSA)
|
||
2 Loss of Signal implemented, signal inverted from standard
|
||
definition in SFP MSA.
|
||
NOTE: This is not standard SFP/GBIC behavior and should
|
||
be avoided, since non-interoperable behavior results.
|
||
1 Loss of Signal implemented, signal as defined in SFP MSA."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.9, SFP-8472 Table 3.1 and 3.7."
|
||
::= { sfpConfigEntry 28 }
|
||
|
||
sfpConfigMaxBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The upper bit rate limit at which the transceiver will still meet its
|
||
specifications (BR, max) is specified in units of 1% above the nominal
|
||
bit rate.
|
||
A value of zero indicates that this field is not specified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 29 }
|
||
|
||
sfpConfigMinBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The lower bit rate limit at which the transceiver will still meet its
|
||
specifications (BR, min) is specified in units of 1% below the nominal
|
||
bit rate.
|
||
A value of zero indicates that this field is not specified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 30 }
|
||
|
||
sfpConfigVendorSN OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor serial number (vendor SN) is a 16 character field that
|
||
contains ASCII characters, left-aligned and padded on the right with
|
||
ASCII spaces (20h), defining thevendor<6F>s serial number for the transceiver.
|
||
A value of all zero in the 16-byte field indicates that the vendor PN is
|
||
unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 31 }
|
||
|
||
sfpConfigDateCode OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The date code is an 6-byte field that contains the vendor<6F>s date
|
||
code in ASCII characters. The date code is mandatory.
|
||
The date code shall be in the format: <yy><mm><dd>."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.10, SFP-8472 Table 3.1 and 3.8."
|
||
::= { sfpConfigEntry 32 }
|
||
|
||
sfpConfigDiagnosticMonitoring OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A field with 8 single bit indicators which describe the
|
||
optional digital diagnostic features implemented in the transceiver.
|
||
Since transceivers will not necessarily implement all optional
|
||
features described in this document, the <20>Enhanced Options<6E> bit field
|
||
allows the host system to determine which functions are
|
||
available over the 2 wire serial bus.
|
||
The bits assignment is:
|
||
7 Reserved for legacy diagnostic implementations.
|
||
Must be <20>0<EFBFBD> for compilance with this document.
|
||
6 Digital diagnostic monitoring implemented (described in this document).
|
||
Must be <20>1<EFBFBD> for compliance with this document.
|
||
5 Internally Calibrated
|
||
4 Externally Calibrated
|
||
3 Received power measurement type 0 = OMA, 1 = Average Power
|
||
2 Address change required."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.11, SFP-8472 Table 3.1 and 3.9."
|
||
::= { sfpConfigEntry 33 }
|
||
|
||
sfpConfigEnhanceOptions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A field with 6 single bit indicators which describe the
|
||
optional digital diagnostic features implemented in the transceiver.
|
||
Since transceivers will not necessarily implement all optional features
|
||
described in this document, the <20>Enhanced Options<6E> bit field allows the
|
||
host system to determine which functions are available over the 2 wire
|
||
serial bus. A <20>1<EFBFBD> indicates that the particular function is
|
||
implemented in the transceiver..
|
||
The bits assignment is:
|
||
Bits 7: Optional Alarm/warning flags implemented for all monitored quantities
|
||
Bits 6: Optional Soft TX_DISABLE control and monitoring implemented
|
||
Bits 5: Optional Soft TX_FAULT monitoring implemented
|
||
Bits 4: Optional Soft RX_LOS monitoring implemented
|
||
Bits 3: Option not enabled in DWDM.
|
||
8472- Optional Soft RATE_SELECT control and monitoring implemented
|
||
Bits 2: Option not enabled in DWDM.
|
||
8472- Optional Application Select control implemented per SFF-8079"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.12, SFP-8472 Table 3.1 and 3.10."
|
||
::= { sfpConfigEntry 34 }
|
||
|
||
sfpConfig8472Compliance OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noDiag(0),
|
||
rev93(1),
|
||
rev94(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An unsigned integer that indicates which feature set(s) are
|
||
implemented in the transceiver.
|
||
The defined values are:
|
||
0 - Digital diagnostic functionality not included or undefined.
|
||
1 - Includes functionality described in Rev 9.3 SFF-8472.
|
||
2 - Includes functionality described in Rev 9.4 SFF-8472."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.14, SFP-8472 Table 3.1 and 3.12."
|
||
::= { sfpConfigEntry 35 }
|
||
|
||
sfpConfigTunableWaveLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Wavelength Tuning Control.
|
||
The availability of this function is indicated in the object sfpConfigChannelSpacing,
|
||
where number of channels greater than 1 indicates tunability.
|
||
The wavelength is set to the channel number written to this byte.
|
||
For a value of 0, channel 1 is selected. For values greater than the maximum channel number,
|
||
the maximum channel number is selected.
|
||
The object value is defaults to 1 on power-up."
|
||
REFERENCE "DWDM MSA Table 2.3.27."
|
||
::= { sfpConfigEntry 36 }
|
||
|
||
sfpConfigVoaControl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Variable Optical Attenuator Control.
|
||
Used to control the wavelength in tunable modules.
|
||
The availability of this function is indicated in Bit 3 of sfpConfigOptionalWdm.
|
||
The amount of attenuation set is given by the Byte value * 0.1 dB,
|
||
and thus ranges from 0 to 25.6 dB.
|
||
The object value defaults to 0 on power-up."
|
||
REFERENCE "DWDM MSA Table 2.3.28."
|
||
::= { sfpConfigEntry 37 }
|
||
|
||
sfpConfigVdtControl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Variable Decision Threshold Control.
|
||
Used to control the variable decision threshold function.
|
||
The availability of this function is indicated in Bit 0 of sfpConfigOptionalWdm.
|
||
The object value is a 2<>s complement 7 bit value (-128 - +127).
|
||
The decision threshold set is given by:
|
||
Decision Threshold = 50% + [VAL/256]*100%
|
||
The object value defaults to 0 on power-up corresponding to 50%."
|
||
REFERENCE "DWDM MSA Table 2.3.29."
|
||
::= { sfpConfigEntry 38 }
|
||
|
||
sfpConfigPilotToneModulation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Pilot Tone Injection Modulation Depth.
|
||
When basic MSA pilot tone injection functionality is implemented
|
||
(as indicated in the Serial ID fields by bits 4-6 of of sfpConfigOptionalWdm)
|
||
Tjis object may be used by the vendor to indicate modulation
|
||
depth per unit control swing on pin 7.
|
||
The modulation depth per control swing is given by:
|
||
Modulation Depth = 0.2% * VAL / Vpp(pin7)
|
||
A value of 0 indicates that the modulation depth per input swing
|
||
is within the range"
|
||
REFERENCE "DWDM MSA Table 2.3.30."
|
||
::= { sfpConfigEntry 39 }
|
||
|
||
sfpConfigCleiCode OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The COMMON LANGUAGE Equipment Code.
|
||
The CLEI code contains an intelligent
|
||
ten-character code that identifies the
|
||
telecommunications equipment.
|
||
The Clei Code resides in the SEEP of the SFP."
|
||
REFERENCE
|
||
"GR-383-CORE"
|
||
::= { sfpConfigEntry 40 }
|
||
|
||
--
|
||
-- XFP Information
|
||
--
|
||
|
||
sfpConfigXfpExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- xfp
|
||
DESCRIPTION
|
||
"This field is used to distinguish between different types of DWDM transceivers and
|
||
different power and environmental classes. The defined identifier values are:
|
||
Bits 7..6:
|
||
00: Power Level 1 Module (1.5 W max. power dissipation.)
|
||
01: Power Level 2 Module (2.5W Max)
|
||
10: Power Level 3 Module (3.5W max. power dissipation.)
|
||
11: Power Level 4 Module (>3.5W max. power dissipation.)
|
||
Bit 5: CDR exist
|
||
0: Module with CDR function
|
||
1: Non-CDR version of XFP
|
||
Bits 5: TX ref clock is required
|
||
0: TX Ref Clock Input Required
|
||
1: TX Ref Clock Input Not Required
|
||
Bits 3: CLEI code is present
|
||
0: No CLEI code present in Table 02h
|
||
1: CLEI code present in Table 02h
|
||
Bits 2..0: Resesrved"
|
||
REFERENCE "XFP INF-8077i Table 47."
|
||
::= { sfpConfigEntry 41 }
|
||
|
||
sfpConfigXfpEncodingCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encoding value indicates the serial encoding mechanism that is the
|
||
nominal design target of the particular transceiver.
|
||
The value shall be contained in the serial data.
|
||
The defined encoding values are:
|
||
Bit 7: 64B/66B
|
||
Bit 6: 8B/10B
|
||
Bit 5: SONET scrambled
|
||
Bit 4: NRZ
|
||
Bit 3: RZ
|
||
Bits 2-0: Reserved."
|
||
REFERENCE "XFP INF-8077i Table 50."
|
||
::= { sfpConfigEntry 42 }
|
||
|
||
sfpConfigXfpMinBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum bit rate (BR, minimum) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second. The bit
|
||
rate includes those bits necessary to encode and delimit the signal as well
|
||
as those bits carrying data information. A value of 0 indicates that the minimum
|
||
bit rate is not specified andmust be determined from the transceiver
|
||
technology. The actual information transfer rate will depend on the encoding
|
||
of the data, as defined by the encoding value. Specific CDR rate
|
||
support is indicated in Byte 164."
|
||
REFERENCE "XFP INF-8077i Section 5.20."
|
||
::= { sfpConfigEntry 43 }
|
||
|
||
sfpConfigXfpMaxBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum bit rate (BR, maximum) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second. The
|
||
bit rate includes those bits necessary to encode and delimit the signal as
|
||
well as those bits carrying data information. A value of 0 indicates that the
|
||
maximum bit rate is not specified and must be determined from the transceiver
|
||
technology. The actual information transfer rate will depend on the
|
||
encoding of the data, as defined by the encoding value. Specific CDR rate
|
||
support is indicated in Byte 164."
|
||
REFERENCE "XFP INF-8077i Section 5.21."
|
||
::= { sfpConfigEntry 44 }
|
||
|
||
sfpConfig10GSonetCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the SONET interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0-1: Reserved
|
||
Bits 2: I-64.5 - 1550 nm, 25 km, SM, IO
|
||
Bits 3: I-64.3 - 1550 nm, 25 km, SM, IO
|
||
Bits 4: I-64.2 - 1550 nm, 25 km, SM, IO
|
||
Bits 5: I-64.2r - 1550 nm, 2 km, SM, VSR
|
||
Bits 6: I-64.1/VSR2000-2R1/P1I1-2D1 - 1310 nm, 2 km, SM, VSR
|
||
Bits 7: I-64.1r/VSR600-2R1 - 1310 nm, 0.6 km, Laser-MM Fibre-SM, VSR
|
||
Bits 8: Reserved
|
||
Bits 9: S-64.5b - 1550 nm, 40 km, SH
|
||
Bits 10: S-64.5a - 1550 nm, 40 km, SH
|
||
Bits 11: S-64.3b
|
||
Bits 12: S-64.3a - 1550 nm, 40 km, SM, SH
|
||
Bits 13: S-64.2b - 1550 nm, 40 km, SM, SH
|
||
Bits 14: S-64.2a - 1550 nm, 40 km, SM, SH
|
||
Bits 15: S-64.1 - 1310 nm, 20 km, IO
|
||
Bits 16-17: Reserved
|
||
Bits 18: G.959.1 P1L1-2D2 - 1550 nm, SM, 80 km, LH
|
||
Bits 19: L-64.3 - 1550 nm, 80 km, LH
|
||
Bits 20: L-64.2c - 1550 nm, 80 km, LH
|
||
Bits 21: L-64.2b - 1550 nm, 80 km, LH
|
||
Bits 22: L-64.2a - 1550 nm, 80 km, LH
|
||
Bits 23: L-64.1 - 1310 nm, SM, 40 km, SH
|
||
Bits 24-28: Reserved
|
||
Bits 29: V-64.3 - 1550 nm, SM, 120 km, VL
|
||
Bits 30: V-64.2b - 1550 nm, SM, 120 km, VL
|
||
Bits 31: V-64.2a - 1550 nm, SM, 120 km, VL."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 45 }
|
||
|
||
sfpConfig10GbeCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the 10GbE interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: Reserved
|
||
Bits 1: 10GBASE-EW - WAN, 1550 nm, SM, ER
|
||
Bits 2: 10GBASE-LW - WAN, 1310 nm, SM, LR
|
||
Bits 3: 10GBASE-SW - WAN, 850 nm, MM, SR
|
||
Bits 4: 10GBASE-LRM (Long reach Multimode) - LAN, 1310 nm, MM, SR fiber, 0.2 km, SR
|
||
Bits 5: 10GBASE-ER (extended range) - LAN, 1550 nm, SM, 40 km, ER
|
||
Bits 6: 10GBASE-LR (Long Range) - LAN, 1310 nm, SM, 10 km, LR
|
||
Bits 7: 10GBASE-SR - LAN, 850 nm, MM, 0.3 km, SR."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 46 }
|
||
|
||
sfpConfig10GFcCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the 10GFC interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
- Fibre Channel link length:
|
||
Bits 0-3: Reserved
|
||
Bits 4: Intermediate Reach 1300 nm FP - 1310 nm, SM, IR
|
||
Bits 5: Extended Reach 1550 nm - 1550 nm, SM, ER
|
||
Bits 6: 1200-SM-LL-L - 1310 nm, SM, LR
|
||
Bits 7: 1200-MX-SN-I - 850 nm, MM, IR."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 47 }
|
||
|
||
sfpConfigXfpDeviceTech OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the XFP device technology:
|
||
Bits 0: 0-Transmitter not Tunable 1-Transmitter Tunable
|
||
Bits 1: Detector Type: 0-PIN detector 1-APD detector
|
||
Bits 2: Cooled transmitter
|
||
Bits 3: Wavelength control: 0-No wavelength control 1-Active wavelength control
|
||
Bits 4-7: Transmitter technology:
|
||
0000b 850 nm VCSEL
|
||
0001b 1310 nm VCSEL
|
||
0010b 1550 nm VCSEL
|
||
0011b 1310 nm FP
|
||
0100b 1310 nm DFB
|
||
0101b 1550 nm DFB
|
||
0110b 1310 nm EML
|
||
0111b 1550 nm EML
|
||
1000b Copper or others
|
||
1001b 1550 nm tunable
|
||
1111b-1001b Reserved."
|
||
REFERENCE "XFP MSA Table 51 and Table 52."
|
||
::= { sfpConfigEntry 48 }
|
||
|
||
sfpConfigXfpTuningSupported OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate the XFP tuning support:
|
||
Bit1: wavelenght (Tunable DWDM - selection in 50 pm steps)
|
||
Bit2: frequency (Tunable DWDM - selection by channel number)
|
||
For exmaple the value 0 means no support, and 3 means both."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 49 }
|
||
|
||
sfpConfigXfpDesiredChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer 1 to N (N=Number of Channels)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 50 }
|
||
|
||
sfpConfigXfpDesiredWl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of Wavelength setpoint (in units of 50 picometers)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 51 }
|
||
|
||
sfpConfigXfpWlError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Monitor of Current Wavelength Error(in units of 5 picometers)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 52 }
|
||
|
||
sfpConfigXfpDesiredFreq OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer to N (N=Number of Channels)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 53 }
|
||
|
||
sfpConfigXfpFreqError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Frequency error reported in 16 bit signed integer with LSB=0.1 GHz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 54 }
|
||
|
||
sfpConfigXfpDitherSupported OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Tx Dither Supported."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 55 }
|
||
|
||
sfpConfigXfpDitherAdmin OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(1), -- enable
|
||
down(2) -- disable
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable the dithering function."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 56 }
|
||
|
||
sfpConfigXfpCapFreqFirstThz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers First Frequency (THz) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 57 }
|
||
|
||
sfpConfigXfpCapFreqFirst10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers First Frequency (GHz*10) capability.
|
||
This value should be added to sfpConfigXfpCapFreqFirstThz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 58 }
|
||
|
||
sfpConfigXfpCapFreqLastThz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers Last Frequency (THz) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 59 }
|
||
|
||
sfpConfigXfpCapFreqLast10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers Last Frequency (GHz*10) capability.
|
||
This value should be added to sfpConfigXfpCapFreqLastThz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 60 }
|
||
|
||
sfpConfigXfpCapMaxSpacing10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers maximum supported grid spacing (GHz*10) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 61 }
|
||
|
||
sfpConfigXfpCalibrationSupported OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Calibarion Supported."
|
||
::= { sfpConfigEntry 62 }
|
||
|
||
sfpConfigXfpCalibrationEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable the calibration process.
|
||
Changing the value to Enable when a signal exist invokes an immidiate calibration process.
|
||
Changing the value to Disable returns the calibration values to defaults."
|
||
::= { sfpConfigEntry 63 }
|
||
|
||
--
|
||
-- CFP Information
|
||
--
|
||
|
||
sfpConfigCfpExtId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended Identifier bit fields:
|
||
Bits 7-6 - Power Class:
|
||
00b: Power Class 1 Module (? 8 W max),
|
||
01b: Power Class 2 Module (?16 W max),
|
||
10b: Power Class 3 Module (? 24 W max),
|
||
11b: Power Class 4 Module (? 32 W max).
|
||
Bits 5-4 Lane Ratio:
|
||
00b: Network lane : Host lane = 1 : n (Mux type),
|
||
01b: Network lane : Host lane = n : m (Gear Box type),
|
||
10b: Network lane : Host lane = n : n (Parallel type),
|
||
11b: Reserved
|
||
Bits 3-1 WDM Type:
|
||
000b: Non-WDM,
|
||
001b: CWDM,
|
||
010b: LANWDM,
|
||
011b: DWDM on 200G-grid,
|
||
100b: DWDM on 100G-grid,
|
||
101b: DWDM on 50G-grid,
|
||
110b: DWDM on 25G-grid,
|
||
111b: Other type WDM
|
||
Bit 0 CLEI Presence:
|
||
0: No CLEI code present,
|
||
1: CLEI code present"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 70 }
|
||
|
||
sfpConfigCfpConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Connector Type Code:
|
||
00h: Undefined,
|
||
01h : SC,
|
||
07h : LC,
|
||
08h : MT-RJ,
|
||
09h : MPO,
|
||
Other Codes : Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 71 }
|
||
|
||
sfpConfigCfpEthernetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet Application Code.
|
||
00h: Undefined type,
|
||
01h: 100GE SMF 10km, 100GE-LR4,
|
||
02h: 100GE SMF 40km, 100GE-ER4,
|
||
03h: 100GE MMF 100m OM3, 100GE-SR10,
|
||
04h: For future use,
|
||
05h: 40GE SMF 10km, 40GE-LR4,
|
||
07h: 40GE MMF 100m OM3, 40GE-SR4,
|
||
For future use:
|
||
100G G.959.1 OTU4
|
||
40G G.693 SDH
|
||
40G G.693 OTU3
|
||
40G G.695 SDH
|
||
40G G.695 OTU3,
|
||
0Dh: 40GE-CR4 Copper
|
||
0Eh: 100GE-CR10 Copper,
|
||
0Fh: 40G BASE-FR,
|
||
10h~FFh: Reserved."
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 72 }
|
||
|
||
sfpConfigCfpFcCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Fiber Channel Application Code: Undefined"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 73 }
|
||
|
||
sfpConfigCfpCopperCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Copper Link Application Code: Undefined"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 74 }
|
||
|
||
sfpConfigCfpSonetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SONET/SDH Application Code:
|
||
00h: Undefined type,
|
||
01h: VSR2000-3R2,
|
||
02h: VSR2000-3R3,
|
||
03h: VSR2000-3R5,
|
||
04h ~ 0FFh: Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 75 }
|
||
|
||
sfpConfigCfpOtnCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OTN Application Code:
|
||
0h: Undefined type,
|
||
01h: VSR2000-3R2F,
|
||
02h: VSR2000-3R3F,
|
||
03h: VSR2000-3R5F,
|
||
04h: VSR2000-3L2F,
|
||
05h: VSR2000-3L3F,
|
||
06h: VSR2000-3L5F,
|
||
07h: C4S1-2D1 (OTL3.4),
|
||
08h: 4I1-9D1F (OTL4.4),
|
||
09h ~ 0FFh: Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 76 }
|
||
|
||
sfpConfigCfpSupportedRates OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Additional Capable Rates Supported Bitmap:
|
||
Bits 7-5 - Reserved
|
||
Bit 4 - 111.8 Gbps
|
||
Bit 3 - 103.125 Gbps
|
||
Bit 2 - 41.25 Gbps
|
||
Bit 1 - 43 Gbps
|
||
Bit 0 - 39.8 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 77 }
|
||
|
||
sfpConfigCfpSupportedLanes OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of Lanes Supported:
|
||
Bits 7-4 - Number of Network Lanes
|
||
The value of 0 represents 16 network lanes supported.
|
||
The values of 1 through 15 represent the actual number of network lanes supported
|
||
Bits 3-0 - Number of Host Lanes
|
||
The value of 0 represents 16 network lanes supported.
|
||
The values of 1 through 15 represent the actual number of network lanes supported"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 78 }
|
||
|
||
sfpConfigCfpMediaProperties OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Media Properties bit fields:
|
||
Bits 7 - 6 Media Type:
|
||
00b: SMF ,
|
||
01b: MMF (OM3),
|
||
10b: Reserved,
|
||
11b: Copper
|
||
Bit 5 - Directionality:
|
||
0: Normal,
|
||
1: BiDi
|
||
Bit 4 Optical Multiplexing and De-multiplexing:
|
||
0: Without optical MUX/DEMUX,
|
||
1: With optical MUX/DEMUX
|
||
Bits 3 - 0 ctive Fiber per Connector:
|
||
A 4-bit unsigned number representing number of active fibers for TX and RX per connector:
|
||
0: 16 TX Lanes and 16 RX Lanes,
|
||
1: 1 TX Lane and 1 RX Lane,
|
||
4: 4 TX Lanes and 4 RX Lanes,
|
||
10: 10 TX Lanes and 10 RX Lanes,
|
||
12: 12 TX Lanes and 12 RX Lanes"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 79 }
|
||
|
||
sfpConfigCfpMaxNetworkLaneRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Network Lane Bit Rate: 8-bit value x 0.2 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 80 }
|
||
|
||
sfpConfigCfpMaxHostLaneRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Host Lane Bit Rate: 8-bit value x 0.2 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 81 }
|
||
|
||
sfpConfigCfpMaxSmFiberLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Single Mode Optical Fiber Length:
|
||
8-bit value x 1 km for single mode fiber length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 82 }
|
||
|
||
sfpConfigCfpMaxMmFiberLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Multi-Mode Optical Fiber Length:
|
||
8-bit value x 10 m for multi-mode fiber length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 83 }
|
||
|
||
sfpConfigCfpMaxCopperCableLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Copper Cable Length:
|
||
8-bit value x 1 m for copper cable length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 84 }
|
||
|
||
sfpConfigCfpMinWavelenPerActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Minimum Wavelength per Active Fiber:
|
||
16-bit unsigned value x 0.025 nm.
|
||
(MSB is at 8012h, LSB is at 8013h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 85 }
|
||
|
||
sfpConfigCfpMaxWavelenPerActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Wavelength per Active Fiber:
|
||
16-bit unsigned value x 0.025 nm.
|
||
(MSB is at 8014h, LSB is at 8015h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 86 }
|
||
|
||
sfpConfigCfpMaxLenOpticalWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum per Lane Optical Width:
|
||
Guaranteed range of laser wavelength.
|
||
16-bit unsigned value x 1 pm.
|
||
(MSB is at 8016h, LSB is at 8017h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 87 }
|
||
|
||
sfpConfigCfpSpacing OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The spacing between two lanes:
|
||
0- unknown spacing
|
||
1 - 100G spacing
|
||
2 - 50G spacing
|
||
3- 25G spacing"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 88 }
|
||
|
||
--
|
||
-- QSFP+ Information
|
||
--
|
||
|
||
sfpConfigQsfppEthernetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum per Lane Optical Width:
|
||
Guaranteed range of laser wavelength.
|
||
16-bit unsigned value x 1 pm.
|
||
(MSB is at 8016h, LSB is at 8017h)"
|
||
REFERENCE "QSFP+ SFF-8436"
|
||
::= { sfpConfigEntry 100 }
|
||
|
||
sfpConfigQsfppSonetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The spacing between two lanes:
|
||
0- unknown spacing
|
||
1 - 100G spacing
|
||
2 - 50G spacing
|
||
3- 25G spacing"
|
||
REFERENCE "QSFP+ SFF-8436"
|
||
::= { sfpConfigEntry 101 }
|
||
|
||
--
|
||
-- CXP Information
|
||
--
|
||
|
||
sfpConfigCxpExtId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended Identifier (Byte 129):
|
||
Bits 7-5 - Power Class:
|
||
000: 0.25W max - Class 0
|
||
001: 1.0W max - Class 1
|
||
010: 1.5W max - Class 2
|
||
011: 2.5W max - Class 3
|
||
100: 4.0W max - Class 4
|
||
101: 6.0W max - Class 5
|
||
110: >6.0W - Class 6
|
||
111: Reserved
|
||
Bits 4 Tx CDR Presence:
|
||
1: Tx CDR provided
|
||
0: Otherwise
|
||
Bits 3 Rx CDR Presence:
|
||
1: Rx CDR provided;
|
||
0: Otherwise"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 110 }
|
||
|
||
sfpConfigCxpConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Connector Type Code (Byte 130):
|
||
30h: Passive Copper Cable Assembly
|
||
31h: Active Copper Cable Assembly (ref. Byte 147)
|
||
32h: Active Optical Cable Assembly
|
||
33h: Optical Transceiver w/ optical connector"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 111 }
|
||
|
||
sfpConfigCxpMaxSupportedRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Max per-channel bit rate (Byte 134):
|
||
Max signal rate = binary value x 100 Mb/s"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 112 }
|
||
|
||
sfpConfigCxpNominalWavelength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Wavelength/Attenuation (Bytes 135-136):
|
||
Optical: Nominal Laser Wavelength --
|
||
Wavelength in nm = value / 20): e.g. 42h 04h = 16,900, 16,900/20 = 845 nm
|
||
Copper: Nominal attenuation of cable either to the other end (passive) or to equalizer (active)
|
||
Byte 135:
|
||
Attenuation at 2.5 GHz in dB -
|
||
00h=no info
|
||
Byte 136:
|
||
Attenuation at 5 GHz in dB -
|
||
00h=no info"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 113 }
|
||
|
||
sfpConfigCxpDeviceTech OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Device Technology (Byte 147):
|
||
Bits 7-4 (Device Technology):
|
||
0000: 850 nm VCSEL
|
||
0001:1310 nm VCSEL
|
||
0010:1550 nm VCSEL
|
||
0011: 1310 nm FP
|
||
0100:1310 nm DFB
|
||
0101:1550 nm DFB
|
||
0110: 1310 nm EML
|
||
0111: 1550 nm EML
|
||
1000: Copper or others
|
||
11001: 1490 nm DFB
|
||
1010: Copper cable un-equalized
|
||
1011: Copper cable passive equalized
|
||
1100: Copper cable near & far end active equalizers
|
||
1101: Copper cable, far end active equalizer
|
||
1110: copper cable, near end active equalizer
|
||
1111: Reserved
|
||
Bit 3 (Wavelength Control):
|
||
0: No control
|
||
1: Active wavelength control
|
||
Bit 2 (Transmitter cooling):
|
||
0: Uncooled transmitter
|
||
1: Cooled transmitter
|
||
Bit 1 (Optical Detector):
|
||
0: P-I-N Detector
|
||
1: APD detector
|
||
Bit 0 (Optical Tunability):
|
||
0: Transmitter not tunable
|
||
1:Transmitter tunable"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 114 }
|
||
|
||
|
||
--
|
||
-- Coherent Information
|
||
--
|
||
|
||
sfpConfigCohRxDesiredChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of RX channel number, which is an integer 1 to N (N=Number of Channels)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 115 }
|
||
|
||
sfpConfigCohRxDesiredWl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of RX Wavelength setpoint (in units of 50 picometers)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 116 }
|
||
|
||
sfpConfigCohRxDesiredFreq OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer to N (N=Number of Channels)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 117 }
|
||
|
||
sfpConfigCohCurrentCD OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current Chromatic Dispersion counter. Units are in ps/nm"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 118 }
|
||
|
||
sfpConfigCohCurrentOSNR OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current SNR. Units are in 0.1dB"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 119 }
|
||
|
||
sfpConfigCohAverageOSNR OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Average SNR over PM interval. Units are in 0.1dB"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 120 }
|
||
|
||
sfpConfigCohMaxCD OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximal Chromatic Dispersion counter. Units are in ps/nm"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 121 }
|
||
|
||
sfpConfigNyquist OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Nyquist - True (ON) or False (OFF). Default is OFF"
|
||
::= { sfpConfigEntry 122 }
|
||
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Diagnostic Table
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpDiagTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SfpDiagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SFP diagnostic table.
|
||
The table defines the status and control of the alarms and warnings
|
||
of the SFP-1310 and the DWDM SFP-15xy modules."
|
||
::= { sfpDiag 1 }
|
||
|
||
sfpDiagEntry OBJECT-TYPE
|
||
SYNTAX SfpDiagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the SFP diagnostic table.
|
||
The index to this table is the same as the ifIndex of the SFP.
|
||
The SFP Diagnostic Table contain and entry for each
|
||
SFP module."
|
||
INDEX { sfpDiagInterface }
|
||
::= { sfpDiagTable 1 }
|
||
|
||
SfpDiagEntry ::=
|
||
SEQUENCE {
|
||
sfpDiagInterface InterfaceIndex,
|
||
|
||
-- Alarms and Warnings Thresholds
|
||
sfpDiagHighTempAlmThreshold INTEGER,
|
||
sfpDiagLowTempAlmThreshold INTEGER,
|
||
sfpDiagHighTempWrnThreshold INTEGER,
|
||
sfpDiagLowTempWrnThreshold INTEGER,
|
||
sfpDiagHighVoltAlmThreshold INTEGER,
|
||
sfpDiagLowVoltAlmThreshold INTEGER,
|
||
sfpDiagHighVoltWrnThreshold INTEGER,
|
||
sfpDiagLowVoltWrnThreshold INTEGER,
|
||
sfpDiagHighTxBiasAlmThreshold INTEGER,
|
||
sfpDiagLowTxBiasAlmThreshold INTEGER,
|
||
sfpDiagHighTxBiasWrnThreshold INTEGER,
|
||
sfpDiagLowTxBiasWrnThreshold INTEGER,
|
||
sfpDiagHighTxPowerAlmThreshold INTEGER,
|
||
sfpDiagLowTxPowerAlmThreshold INTEGER,
|
||
sfpDiagHighTxPowerWrnThreshold INTEGER,
|
||
sfpDiagLowTxPowerWrnThreshold INTEGER,
|
||
sfpDiagHighRxPowerAlmThreshold INTEGER,
|
||
sfpDiagLowRxPowerAlmThreshold INTEGER,
|
||
sfpDiagHighRxPowerWrnThreshold INTEGER,
|
||
sfpDiagLowRxPowerWrnThreshold INTEGER,
|
||
sfpDiagHighLaserTempAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowLaserTempAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighLaserTempWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowLaserTempWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagHighWaveLenAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowWaveLenAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighWaveLenWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowWaveLenWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagHighTecCurrAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowTecCurrAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighTecCurrWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowTecCurrWrnThreshold INTEGER, -- 15xy
|
||
|
||
-- Measured Values
|
||
sfpDiagModuleTemperature INTEGER,
|
||
sfpDiagSupplyVoltage INTEGER,
|
||
sfpDiagTxBias INTEGER,
|
||
sfpDiagTxOutputPower INTEGER,
|
||
sfpDiagRxInputPower INTEGER,
|
||
sfpDiagRxLaserTemperature INTEGER, -- 15xy
|
||
sfpDiagRxMeasuredWavelength INTEGER, -- 15xy
|
||
sfpDiagRxTecCurrent INTEGER, -- 15xy
|
||
|
||
-- Status and Control
|
||
sfpDiagAlarms INTEGER,
|
||
sfpDiagAlarmsMask INTEGER,
|
||
sfpDiagWarnings INTEGER,
|
||
sfpDiagWarningsMask INTEGER,
|
||
sfpDiagConfLowRxPowerAlmThreshold INTEGER,
|
||
sfpDiagRxInputPowerFloat Float32TC,
|
||
|
||
-- CXP
|
||
sfpDiagCxpTxTemp INTEGER,
|
||
sfpDiagCxpHighTxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpLowTxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpRxTemp INTEGER,
|
||
sfpDiagCxpHighRxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpLowRxTempAlmThreshold INTEGER,
|
||
|
||
-- OTDR
|
||
sfpDiagOtdrFiberCutRange INTEGER,
|
||
sfpDiagModuleTemperatureCelsius INTEGER
|
||
}
|
||
|
||
sfpDiagInterface OBJECT-TYPE
|
||
SYNTAX InterfaceIndex
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Interface Index of the SFP (type=196)."
|
||
::= { sfpDiagEntry 1 }
|
||
-- Alarms and Warnings Thresholds
|
||
|
||
sfpDiagHighTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 2 }
|
||
|
||
sfpDiagLowTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 3 }
|
||
|
||
sfpDiagHighTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 4 }
|
||
|
||
sfpDiagLowTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 5 }
|
||
|
||
sfpDiagHighVoltAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 6 }
|
||
|
||
sfpDiagLowVoltAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 7 }
|
||
|
||
sfpDiagHighVoltWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 8 }
|
||
|
||
sfpDiagLowVoltWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 9 }
|
||
|
||
sfpDiagHighTxBiasAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 10 }
|
||
|
||
sfpDiagLowTxBiasAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 11 }
|
||
|
||
sfpDiagHighTxBiasWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 12 }
|
||
|
||
sfpDiagLowTxBiasWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 13 }
|
||
|
||
sfpDiagHighTxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high TX power alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 14 }
|
||
|
||
sfpDiagLowTxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low TX power alarm. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 15 }
|
||
|
||
sfpDiagHighTxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high TX power warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 16 }
|
||
|
||
sfpDiagLowTxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low TX power warning. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 17 }
|
||
|
||
sfpDiagHighRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high RX power alarm. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 18 }
|
||
|
||
sfpDiagLowRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low RX power alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 19 }
|
||
|
||
sfpDiagHighRxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high RX power warning. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 20 }
|
||
|
||
sfpDiagLowRxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low RX power warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 21 }
|
||
|
||
sfpDiagHighLaserTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write -- 15xy
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 22 }
|
||
|
||
sfpDiagLowLaserTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 23 }
|
||
|
||
sfpDiagHighLaserTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 24 }
|
||
|
||
sfpDiagLowLaserTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write -- 15xy
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 25 }
|
||
|
||
sfpDiagHighWaveLenAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature alarm.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 26 }
|
||
|
||
sfpDiagLowWaveLenAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature alarm.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 27 }
|
||
|
||
sfpDiagHighWaveLenWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature warning.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 28 }
|
||
|
||
sfpDiagLowWaveLenWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature warning.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 29 }
|
||
|
||
sfpDiagHighTecCurrAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for high TEC current alarm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 30 }
|
||
|
||
sfpDiagLowTecCurrAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for low TEC current alarm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 31 }
|
||
|
||
sfpDiagHighTecCurrWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for high TEC current warning.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 32 }
|
||
|
||
sfpDiagLowTecCurrWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for low TEC current warning.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 33 }
|
||
|
||
-- Diagnostics Measured Values
|
||
|
||
sfpDiagModuleTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured module temperature. The value 0 means -128 Celsuis.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20>3
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 34 }
|
||
|
||
sfpDiagSupplyVoltage OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured supply voltage in transceiver. The value 0 means 0 Volts.
|
||
An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts.
|
||
Accuracy is vendor specific but must be better than <20>3% of the
|
||
manufacturer<65>s nominal value over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 35 }
|
||
|
||
sfpDiagTxBias OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured TX Bias Current. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA.
|
||
Accuracy is vendor specific but must be better than <20>3dB over specified
|
||
temperature and voltage. Data is not valid when the transmitter is disabled."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 36 }
|
||
|
||
sfpDiagTxOutputPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured TX output power. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW.
|
||
For the vendor specified wavelength, accuracy shall be better than <20>3dB
|
||
over specified temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 37 }
|
||
|
||
sfpDiagRxInputPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured RX input power. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW.
|
||
For the vendor specified wavelength, accuracy shall be better than <20>3dB
|
||
over specified temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 38 }
|
||
|
||
sfpDiagRxLaserTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Temperature.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent
|
||
to 1/256 degree, yielding a total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20> 0.2
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 39 }
|
||
|
||
sfpDiagRxMeasuredWavelength OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Wavelength.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The wavelength is defined as:
|
||
Wavelength = 1000nm + 0.01nm * 16 bit value.
|
||
Thus, the reportable wavelength range is 1000.00 <20> 1655.35nm with a
|
||
resolution of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 40 }
|
||
|
||
sfpDiagRxTecCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Temperature or Wavelength.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7,
|
||
The accuracy of the TEC current monitor is vendor specific but must be
|
||
better than <20>15% of the maximum TEC current as stored in the TEC Current
|
||
High Alarm Threshold"
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 41 }
|
||
|
||
-- Status and Control
|
||
|
||
sfpDiagAlarms OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Alarms of the SFP module.
|
||
The sfpDiagAlarms is a bit map represented as a sum, therefore,
|
||
it can represent multiple failures (alarms) simultaneously.
|
||
The various bit positions are:
|
||
0 Temp High Alarm Set when internal temperature exceeds high alarm level.
|
||
1 Temp Low Alarm Set when internal temperature is below low alarm level.
|
||
2 Vcc High Alarm Set when internal supply voltage exceeds high alarm level.
|
||
3 Vcc Low Alarm Set when internal supply voltage is below low alarm level.
|
||
4 TX Bias High Alarm Set when TX Bias current exceeds high alarm level.
|
||
5 TX Bias Low Alarm Set when TX Bias current is below low alarm level.
|
||
6 TX Power High Alarm Set when TX output power exceeds high alarm level.
|
||
7 TX Power Low Alarm Set when TX output power is below low alarm level.
|
||
8 RX Power High Alarm Set when Received Power exceeds high alarm level.
|
||
9 RX Power Low Alarm Set when Received Power is below low alarm level.
|
||
10 (15xy) Laser T/W High Alarm Set when laser temperature or wavelength exceeds high alarm level.
|
||
11 (15xy) Laser T/W Low Alarm Set when laser temperature or wavelength is below low alarm level.
|
||
12 (15xy) TEC Current High Alarm Set when TEC current exceeds high alarm level.
|
||
13 (15xy) TEC Current Low Alarm Set when TEC current is below low alarm level.
|
||
14 Retimer Loss Of Lock
|
||
15 Removed SFP
|
||
16 Rx Signal Detect alarm
|
||
17 Laser End of Life
|
||
18 Laser Tx Failure Indication."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 42 }
|
||
|
||
sfpDiagAlarmsMask OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Masking of the Alarms of the SFP module.
|
||
The sfpDiagAlarmsMask is a bit map. Any of the alarm and warning flags can
|
||
be masked by writing a 1 to the corresponding bits.
|
||
The various bit positions are:
|
||
0 Temp High Wanring Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Wanring Set when internal temperature is below low warning level.
|
||
2 Vcc High Wanring Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Wanring Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Wanring Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Wanring Set when TX Bias current is below low warning level.
|
||
6 TX Power High Wanring Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Wanring Set when TX output power is below low warning level.
|
||
8 RX Power High Wanring Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Wanring Set when Received Power is below low warning level.
|
||
10 (15xy) Laser T/W High Wanring Set when laser temperature or wavelength exceeds high warning level.
|
||
11 (15xy) Laser T/W Low Wanring Set when laser temperature or wavelength is below low warning level.
|
||
12 (15xy) TEC Current High Wanring Set when TEC current exceeds high warning level.
|
||
13 (15xy) TEC Current Low Wanring Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 43 }
|
||
|
||
sfpDiagWarnings OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Warnings of the SFP module.
|
||
The sfpDiagWarnings is a bit map represented as a sum, therefore,
|
||
it can represent multiple failures (alarms) simultaneously.
|
||
The various bit positions are:
|
||
0 Temp High Warning Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Warning Set when internal temperature is below low warning level.
|
||
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
|
||
6 TX Power High Warning Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Warning Set when TX output power is below low warning level.
|
||
8 RX Power High Warning Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Warning Set when Received Power is below low warning level.
|
||
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
|
||
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
|
||
12 TEC Current High Warning Set when TEC current exceeds high warning level.
|
||
13 TEC Current Low Warning Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 44 }
|
||
|
||
sfpDiagWarningsMask OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Masking of the Warnings of the SFP module.
|
||
The sfpDiagWarningsMask is a bit map. Any of the alarm and warning flags can
|
||
be masked by writing a 1 to the corresponding bits.
|
||
The various bit positions are:
|
||
0 Temp High Warning Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Warning Set when internal temperature is below low warning level.
|
||
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
|
||
6 TX Power High Warning Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Warning Set when TX output power is below low warning level.
|
||
8 RX Power High Warning Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Warning Set when Received Power is below low warning level.
|
||
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
|
||
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
|
||
12 TEC Current High Warning Set when TEC current exceeds high warning level.
|
||
13 TEC Current Low Warning Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 45 }
|
||
|
||
sfpDiagConfLowRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configured threshold value for low RX power alarm.
|
||
Changing this value doen't affect the SFP and is implemented by software.
|
||
The threshold level specified in 0.1 dBm units.
|
||
The range starts with -50.0 dBm."
|
||
::= { sfpDiagEntry 46 }
|
||
|
||
sfpDiagRxInputPowerFloat OBJECT-TYPE
|
||
SYNTAX Float32TC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured RX input power sepcified in floating units.
|
||
This object is used for power < -40dBm that can be achieved with SFP external calibration.
|
||
When not used this value is 0 and sfpDiagRxInputPower should be used."
|
||
::= { sfpDiagEntry 47 }
|
||
|
||
--
|
||
-- CXP
|
||
--
|
||
|
||
sfpDiagCxpTxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured Tx temperature. The value 0 means -128 Celsius.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 22-23 (Tx Lower Page)"
|
||
::= { sfpDiagEntry 50 }
|
||
|
||
sfpDiagCxpHighTxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high Tx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 128-129 (Tx Upper Page)"
|
||
::= { sfpDiagEntry 51 }
|
||
|
||
sfpDiagCxpLowTxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low Tx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 130-131 (Tx Upper Page)"
|
||
::= { sfpDiagEntry 52 }
|
||
|
||
sfpDiagCxpRxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured Rx temperature. The value 0 means -128 Celsius.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 22-23 (Rx Lower Page)"
|
||
::= { sfpDiagEntry 53 }
|
||
|
||
sfpDiagCxpHighRxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high Rx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 128-129 (Rx Upper Page)"
|
||
::= { sfpDiagEntry 54 }
|
||
|
||
sfpDiagCxpLowRxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low Rx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 130-131 (Rx Upper Page)"
|
||
::= { sfpDiagEntry 55 }
|
||
|
||
sfpDiagOtdrFiberCutRange OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The OTDR calculated range to the fiber cut"
|
||
::= { sfpDiagEntry 56 }
|
||
|
||
sfpDiagModuleTemperatureCelsius OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured module temperature, while degress in Celsuis.
|
||
Total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20>3
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 57 }
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Traps
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpConfigChangeTrap NOTIFICATION-TYPE
|
||
OBJECTS { sfpConfigInterface }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A sfpTrapsChangeTrap trap is sent when the
|
||
content of an instance sfpConfigEntry changes. It
|
||
can be utilized by an NMS to trigger polls."
|
||
::= { sfpTraps 1 }
|
||
|
||
END
|