2634 lines
73 KiB
Plaintext
2634 lines
73 KiB
Plaintext
TRIPPLITE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayString,
|
|
TruthValue,
|
|
TimeStamp,
|
|
TimeInterval,
|
|
DateAndTime,
|
|
AutonomousType,
|
|
VariablePointer,
|
|
RowStatus
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
MODULE-IDENTITY,
|
|
OBJECT-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Gauge32,
|
|
Integer32,
|
|
enterprises,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
PositiveInteger,
|
|
NonNegativeInteger
|
|
FROM UPS-MIB;
|
|
|
|
tripplite MODULE-IDENTITY
|
|
LAST-UPDATED "200904270000Z"
|
|
ORGANIZATION "Tripplite Inc"
|
|
CONTACT-INFO
|
|
"Mike Delgroso
|
|
Tripplite, Inc.
|
|
1111 W. 35th St.
|
|
Chicago, IL 60609"
|
|
DESCRIPTION
|
|
"This MIB module defines MIB objects which provide mechanisms for
|
|
remote management capabilities of Tripplite PowerAlert and related
|
|
software."
|
|
REVISION "200904270000Z"
|
|
DESCRIPTION
|
|
"Added tlUpsAlarmOutputCurrentChanged well known alarm trap"
|
|
REVISION "200810140000Z"
|
|
DESCRIPTION
|
|
"Added tlUpsOutletCurrentTable and tlUpsOutletPowerTable to publish load-specific variables"
|
|
REVISION "200809250000Z"
|
|
DESCRIPTION
|
|
"Added tlUpsOutletGroupTable."
|
|
REVISION "200802010000Z"
|
|
DESCRIPTION
|
|
"V1 trap decode support."
|
|
REVISION "200711300000Z"
|
|
DESCRIPTION
|
|
"Changed tlUpsAlarmTime to int to match implementation, same for tlUpsAlarmDescr to string"
|
|
REVISION "200711290000Z"
|
|
DESCRIPTION
|
|
"Changed tlUpsConfigBattReplDate and tlUpsTestDate from integer back to string."
|
|
REVISION "200708260000Z"
|
|
DESCRIPTION
|
|
"Migrated changes from 12.04.0034, which included Load -> Outlet."
|
|
REVISION "200702280000Z"
|
|
DESCRIPTION
|
|
"Renamed Load to Outlet. Cleaned up MIB compilation errors."
|
|
REVISION "200612120000Z"
|
|
DESCRIPTION
|
|
"Changed tlUpsConfigBattReplDate and tlUpsTestDate from string to integer."
|
|
REVISION "200612060000Z"
|
|
DESCRIPTION
|
|
"Implement tlUpsOutletTable."
|
|
REVISION "200606200000Z"
|
|
DESCRIPTION
|
|
"Implemented tlUpsAlarmTable to coincide with upsAlarmTable, but
|
|
all for additional variables."
|
|
REVISION "200507130000Z"
|
|
DESCRIPTION
|
|
"Modifications to bring MIB into compliance. Changed OID name from
|
|
upsLoadNumLoads to tlUpsLoadNumLoads."
|
|
REVISION "200305160000Z"
|
|
DESCRIPTION
|
|
"Initial release, for PowerAlert Version 12."
|
|
::= { enterprises 850 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- Enumerations
|
|
--------------------------------------------------------------------------
|
|
|
|
tlEnumerations OBJECT IDENTIFIER ::= { tripplite 2 }
|
|
|
|
tlOperatingSystems OBJECT IDENTIFIER ::= { tlEnumerations 1 }
|
|
|
|
hpux9 OBJECT IDENTIFIER ::= { tlOperatingSystems 1 }
|
|
|
|
sunos4 OBJECT IDENTIFIER ::= { tlOperatingSystems 2 }
|
|
|
|
solaris OBJECT IDENTIFIER ::= { tlOperatingSystems 3 }
|
|
|
|
osf OBJECT IDENTIFIER ::= { tlOperatingSystems 4 }
|
|
|
|
ultrix OBJECT IDENTIFIER ::= { tlOperatingSystems 5 }
|
|
|
|
hpux10 OBJECT IDENTIFIER ::= { tlOperatingSystems 6 }
|
|
|
|
netbsd1 OBJECT IDENTIFIER ::= { tlOperatingSystems 7 }
|
|
|
|
freebsd OBJECT IDENTIFIER ::= { tlOperatingSystems 8 }
|
|
|
|
irix OBJECT IDENTIFIER ::= { tlOperatingSystems 9 }
|
|
|
|
linux OBJECT IDENTIFIER ::= { tlOperatingSystems 10 }
|
|
|
|
bsdi OBJECT IDENTIFIER ::= { tlOperatingSystems 11 }
|
|
|
|
openbsd OBJECT IDENTIFIER ::= { tlOperatingSystems 12 }
|
|
|
|
win32 OBJECT IDENTIFIER ::= { tlOperatingSystems 13 }
|
|
|
|
hpux11 OBJECT IDENTIFIER ::= { tlOperatingSystems 14 }
|
|
|
|
win9x OBJECT IDENTIFIER ::= { tlOperatingSystems 50 }
|
|
|
|
winnt OBJECT IDENTIFIER ::= { tlOperatingSystems 51 }
|
|
|
|
solspark OBJECT IDENTIFIER ::= { tlOperatingSystems 52 }
|
|
|
|
solintel OBJECT IDENTIFIER ::= { tlOperatingSystems 53 }
|
|
|
|
aix OBJECT IDENTIFIER ::= { tlOperatingSystems 54 }
|
|
|
|
sco OBJECT IDENTIFIER ::= { tlOperatingSystems 55 }
|
|
|
|
osx OBJECT IDENTIFIER ::= { tlOperatingSystems 56 }
|
|
|
|
unknown OBJECT IDENTIFIER ::= { tlOperatingSystems 255 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- UPS Device
|
|
--------------------------------------------------------------------------
|
|
|
|
tlUPS OBJECT IDENTIFIER ::= { tripplite 100 }
|
|
|
|
tlUpsObjects OBJECT IDENTIFIER ::= { tlUPS 1 }
|
|
|
|
tlUpsIdent OBJECT IDENTIFIER ::= { tlUpsObjects 1 }
|
|
|
|
tlUpsIdentUpsSoftwareChecksum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A checksum for the UPS fostware."
|
|
::= { tlUpsIdent 1 }
|
|
|
|
tlUpsIdentSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number for the UPS."
|
|
::= { tlUpsIdent 2 }
|
|
|
|
tlUpsIdentID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user-supplied ID for the UPS."
|
|
::= { tlUpsIdent 3 }
|
|
|
|
tlUpsSnmpCardSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number for the UPS."
|
|
::= { tlUpsIdent 4 }
|
|
|
|
|
|
tlUpsBattery OBJECT IDENTIFIER ::= { tlUpsObjects 2 }
|
|
|
|
tlUpsBatteryAge OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The age of the battery, in the format YYYYMMDD. This is equal to
|
|
the current date minus tlConfigBattReplDate."
|
|
::= { tlUpsBattery 1 }
|
|
|
|
|
|
tlUpsTemperatureF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature of the battery, in Farenheight degrees. This is
|
|
calculated from upsBatteryTemperature, which is in Celsius degrees."
|
|
::= { tlUpsBattery 2 }
|
|
|
|
|
|
tlUpsInput OBJECT IDENTIFIER ::= { tlUpsObjects 3 }
|
|
|
|
tlUpsOutput OBJECT IDENTIFIER ::= { tlUpsObjects 4 }
|
|
|
|
tlUpsBypass OBJECT IDENTIFIER ::= { tlUpsObjects 5 }
|
|
|
|
tlUpsAlarm OBJECT IDENTIFIER ::= { tlUpsObjects 6 }
|
|
|
|
tlUpsAlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { tlUpsAlarm 1 }
|
|
|
|
tlUpsAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlUpsAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries."
|
|
::= { tlUpsAlarm 2 }
|
|
|
|
tlUpsAlarmEntry OBJECT-TYPE
|
|
SYNTAX TlUpsAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a particular alarm."
|
|
INDEX { tlUpsAlarmId }
|
|
::= { tlUpsAlarmTable 1 }
|
|
|
|
TlUpsAlarmEntry ::= SEQUENCE {
|
|
tlUpsAlarmId PositiveInteger,
|
|
tlUpsAlarmDescr AutonomousType,
|
|
tlUpsAlarmTime TimeStamp,
|
|
tlUpsAlarmDetail DisplayString,
|
|
tlUpsAlarmDeviceId PositiveInteger,
|
|
tlUpsAlarmDeviceName DisplayString,
|
|
tlUpsAlarmLocation DisplayString,
|
|
tlUpsAlarmGroup INTEGER,
|
|
tlUpsAlarmIp IpAddress,
|
|
tlUpsAlarmMac DisplayString
|
|
}
|
|
|
|
tlUpsAlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition."
|
|
::= { tlUpsAlarmEntry 1 }
|
|
|
|
tlUpsAlarmDescr OBJECT-TYPE
|
|
SYNTAX STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the alarm condition."
|
|
::= { tlUpsAlarmEntry 2 }
|
|
|
|
tlUpsAlarmTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was detected."
|
|
::= { tlUpsAlarmEntry 3 }
|
|
|
|
tlUpsAlarmDetail OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of the alarm condition."
|
|
::= { tlUpsAlarmEntry 4 }
|
|
|
|
tlUpsAlarmDeviceId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A numeric identifier for the device on which the alarm is active."
|
|
::= { tlUpsAlarmEntry 5 }
|
|
|
|
tlUpsAlarmDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifier for the device on which the alarm is active."
|
|
::= { tlUpsAlarmEntry 6 }
|
|
|
|
tlUpsAlarmLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The location of the device on which the alarm is active."
|
|
::= { tlUpsAlarmEntry 7 }
|
|
|
|
tlUpsAlarmGroup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
warning(2),
|
|
info(3),
|
|
status(4),
|
|
offline(5),
|
|
custom(6) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The category/group of this alarm."
|
|
::= { tlUpsAlarmEntry 8 }
|
|
|
|
tlUpsAlarmIp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The originating IP address associated with this alarm."
|
|
::= { tlUpsAlarmEntry 9 }
|
|
|
|
tlUpsAlarmMac OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The originating mac address associated with this alarm."
|
|
::= { tlUpsAlarmEntry 10 }
|
|
|
|
tlUpsWellKnownAlarms OBJECT IDENTIFIER ::= { tlUpsAlarm 3 }
|
|
|
|
tlUpsAlarmPrimaryPowerOutage OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The primary power source is not present."
|
|
::= { tlUpsWellKnownAlarms 1 }
|
|
|
|
tlUpsAlarmSecondaryPowerOutage OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The secondary power source is not present."
|
|
::= { tlUpsWellKnownAlarms 2 }
|
|
|
|
tlUpsAlarmLoadLevelAboveThreshold OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load level is above the designated threshold."
|
|
::= { tlUpsWellKnownAlarms 3 }
|
|
|
|
tlUpsAlarmOutputCurrentChanged OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output current changed from its last known value."
|
|
::= { tlUpsWellKnownAlarms 4 }
|
|
|
|
tlUpsAlarmDevName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The name of the device, tlDevName, corresponding to the device that is
|
|
associated with this alarm."
|
|
::= { tlUpsAlarm 7 }
|
|
|
|
tlUpsAlarmDevLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The location of the device, tlDevLocation, corresponding to the device
|
|
that is associated with this alarm."
|
|
::= { tlUpsAlarm 8 }
|
|
|
|
tlUpsAlarmCategory OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The category, tlDevEvtCategory, of this alarm."
|
|
::= { tlUpsAlarm 9 }
|
|
|
|
|
|
|
|
tlUpsTest OBJECT IDENTIFIER ::= { tlUpsObjects 7 }
|
|
|
|
tlUpsTestDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date of the last self-test run on the ups, in the
|
|
format YYYYMMDD."
|
|
::= { tlUpsTest 1 }
|
|
|
|
tlUpsTestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last self-test run on the ups."
|
|
::= { tlUpsTest 2 }
|
|
|
|
tlUpsControl OBJECT IDENTIFIER ::= { tlUpsObjects 8 }
|
|
|
|
tlUpsWatchdogSupported OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not this UPS supports a watchdog reboot."
|
|
::= { tlUpsControl 1 }
|
|
|
|
|
|
tlUpsWatchdogSecsBeforeReboot OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of seconds that can expire between polls that
|
|
the engine makes to the UPS for data. If this time runs out, then
|
|
the UPS will cycle its outputs. Set this to zero to turns disable
|
|
this feature."
|
|
::= { tlUpsControl 2 }
|
|
|
|
tlUpsWellKnownControls OBJECT IDENTIFIER ::= { tlUpsControl 3 }
|
|
|
|
tlUpsControlSelfTest OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to TRUE to initiate Self Test"
|
|
::= { tlUpsWellKnownControls 1 }
|
|
|
|
tlUpsControlRamp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to TRUE to initiate Ramp"
|
|
::= { tlUpsWellKnownControls 2 }
|
|
|
|
tlUpsControlShed OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to TRUE to initiate Shed"
|
|
::= { tlUpsWellKnownControls 3 }
|
|
|
|
tlUpsControlUpsOn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to TRUE to turn UPS on"
|
|
::= { tlUpsWellKnownControls 4 }
|
|
|
|
tlUpsControlUpsOff OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to TRUE to turn UPS off"
|
|
::= { tlUpsWellKnownControls 5 }
|
|
|
|
tlUpsConfig OBJECT IDENTIFIER ::= { tlUpsObjects 9 }
|
|
|
|
tlUpsConfigBattReplDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date on which the battery was last replaced, in the format
|
|
YYYYMMDD."
|
|
::= { tlUpsConfig 1 }
|
|
|
|
tlUpsConfigTftpGetAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of the TFTP server you wish to acquire a config ini file from, non persistent, 0.0.0.0 when empty"
|
|
::= { tlUpsConfig 2 }
|
|
|
|
tlUpsConfigTftpGetAcction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
get(1),
|
|
getting(2),
|
|
idle(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"setting this entry to get(1) will start a down load from the specified address, during the download this entry
|
|
will read getting(2), when finished, the card will reboot to the new ini supplied parms. At all other times this
|
|
entry will read idle(3)"
|
|
::= { tlUpsConfig 3 }
|
|
|
|
|
|
tlUpsOutlet OBJECT IDENTIFIER ::= { tlUpsObjects 10 }
|
|
|
|
tlUpsOutletNumOutlets OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of available Outlets in this device."
|
|
::= { tlUpsOutlet 1 }
|
|
|
|
tlUpsOutletTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlUpsOutletEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of all device Outlets for all devices."
|
|
::= { tlUpsOutlet 2 }
|
|
|
|
tlUpsOutletEntry OBJECT-TYPE
|
|
SYNTAX TlUpsOutletEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing Outlet information applicable to a particular
|
|
device managed by this agent."
|
|
INDEX {
|
|
tlUpsOutletIndex }
|
|
::= { tlUpsOutletTable 1 }
|
|
|
|
TlUpsOutletEntry ::= SEQUENCE {
|
|
tlUpsOutletIndex PositiveInteger,
|
|
tlUpsOutletState INTEGER,
|
|
tlUpsOutletType Integer32,
|
|
tlUpsOutletControl INTEGER,
|
|
tlUpsOutletName DisplayString,
|
|
tlUpsOutletRampAction INTEGER,
|
|
tlUpsOutletRampDataType INTEGER,
|
|
tlUpsOutletRampData Integer32,
|
|
tlUpsOutletShedAction INTEGER,
|
|
tlUpsOutletShedDataType INTEGER,
|
|
tlUpsOutletShedData Integer32,
|
|
tlUpsOutletGroupNdx Integer32 }
|
|
|
|
tlUpsOutletIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index number of this Outlet for the device
|
|
indicated by tlDeviceIndex."
|
|
::= { tlUpsOutletEntry 1 }
|
|
|
|
tlUpsOutletState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
off(1),
|
|
on(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the Outlet."
|
|
::= { tlUpsOutletEntry 2 }
|
|
|
|
tlUpsOutletType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a bit field that indicates the type of this Outlet.
|
|
|
|
Bit Display
|
|
0 Battery Protected
|
|
1 Controllable
|
|
2
|
|
3
|
|
4
|
|
5
|
|
6
|
|
7
|
|
8
|
|
9
|
|
10
|
|
11
|
|
12
|
|
13
|
|
14
|
|
15
|
|
"
|
|
::= { tlUpsOutletEntry 3 }
|
|
|
|
tlUpsOutletControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnOff(1),
|
|
turnOn(2),
|
|
cycle(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the state of the Outlet."
|
|
::= { tlUpsOutletEntry 4 }
|
|
|
|
tlUpsOutletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the device."
|
|
::= { tlUpsOutletEntry 5 }
|
|
|
|
|
|
tlUpsOutletRampAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
remainOff(0),
|
|
turnOnAfterDelay(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ramp action to take on the Outlet."
|
|
::= { tlUpsOutletEntry 6 }
|
|
|
|
tlUpsOutletRampDataType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
delayInSeconds(0)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of data associated with ramp action."
|
|
::= { tlUpsOutletEntry 7 }
|
|
|
|
tlUpsOutletRampData OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data value associated with type of ramp data."
|
|
::= { tlUpsOutletEntry 8 }
|
|
|
|
tlUpsOutletShedAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
remainOn(0),
|
|
turnOffAfterDelay(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shed action to take on the Outlet."
|
|
::= { tlUpsOutletEntry 9 }
|
|
|
|
tlUpsOutletShedDataType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
delayInSeconds(0)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of data associated with shed action."
|
|
::= { tlUpsOutletEntry 10 }
|
|
|
|
tlUpsOutletShedData OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data value associated with type of shed data."
|
|
::= { tlUpsOutletEntry 11 }
|
|
|
|
tlUpsOutletGroupNdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tlUpsOutletGroupIndex of corresponding outlet group, or 0 if ungrouped."
|
|
::= { tlUpsOutletEntry 12 }
|
|
|
|
|
|
tlUpsOutletCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlUpsOutletCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of load currents."
|
|
::= { tlUpsOutlet 3 }
|
|
|
|
tlUpsOutletCurrentEntry OBJECT-TYPE
|
|
SYNTAX TlUpsOutletCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing Outlet current information applicable to a particular
|
|
device managed by this agent."
|
|
INDEX {
|
|
tlUpsOutletCurrentIndex }
|
|
::= { tlUpsOutletCurrentTable 1 }
|
|
|
|
TlUpsOutletCurrentEntry ::= SEQUENCE {
|
|
tlUpsOutletCurrentIndex PositiveInteger,
|
|
tlUpsOutletCurrentValue PositiveInteger }
|
|
|
|
tlUpsOutletCurrentIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index number of this Outlet."
|
|
::= { tlUpsOutletCurrentEntry 1 }
|
|
|
|
tlUpsOutletCurrentValue OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this outlet's current, represented as 0.1A"
|
|
::= { tlUpsOutletCurrentEntry 2 }
|
|
|
|
|
|
tlUpsOutletPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlUpsOutletPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of load power."
|
|
::= { tlUpsOutlet 4 }
|
|
|
|
tlUpsOutletPowerEntry OBJECT-TYPE
|
|
SYNTAX TlUpsOutletPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing Outlet power information applicable to a particular
|
|
device managed by this agent."
|
|
INDEX {
|
|
tlUpsOutletPowerIndex }
|
|
::= { tlUpsOutletPowerTable 1 }
|
|
|
|
TlUpsOutletPowerEntry ::= SEQUENCE {
|
|
tlUpsOutletPowerIndex PositiveInteger,
|
|
tlUpsOutletPowerValue PositiveInteger }
|
|
|
|
tlUpsOutletPowerIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index number of this Outlet."
|
|
::= { tlUpsOutletPowerEntry 1 }
|
|
|
|
tlUpsOutletPowerValue OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this outlet's power in watts."
|
|
::= { tlUpsOutletPowerEntry 2 }
|
|
|
|
|
|
tlUpsOutletGroup OBJECT IDENTIFIER ::= { tlUpsObjects 11 }
|
|
|
|
tlUpsOutletNumOutletGroups OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of available Outlet Groups in this device."
|
|
::= { tlUpsOutletGroup 1 }
|
|
|
|
tlUpsOutletGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlUpsOutletGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of device outlet group entries. The number of entries is
|
|
given by the value of tlUpsOutletNumOutletGroups."
|
|
::= { tlUpsOutletGroup 2 }
|
|
|
|
tlUpsOutletGroupEntry OBJECT-TYPE
|
|
SYNTAX TlUpsOutletGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing outlet group information applicable
|
|
to a particular device managed by this agent"
|
|
INDEX { tlUpsOutletGroupIndex }
|
|
::= { tlUpsOutletGroupTable 1 }
|
|
|
|
TlUpsOutletGroupEntry ::= SEQUENCE {
|
|
tlUpsOutletGroupIndex PositiveInteger,
|
|
tlUpsOutletGroupUnused Integer32,
|
|
tlUpsOutletGroupName DisplayString,
|
|
tlUpsOutletGroupDesc DisplayString,
|
|
tlUpsOutletGroupState INTEGER,
|
|
tlUpsOutletGroupControl INTEGER }
|
|
|
|
tlUpsOutletGroupIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the index number of this load group for the device."
|
|
::= { tlUpsOutletGroupEntry 1 }
|
|
|
|
tlUpsOutletGroupUnused OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unused placeholder"
|
|
::= { tlUpsOutletGroupEntry 2 }
|
|
|
|
tlUpsOutletGroupName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of this outlet group."
|
|
::= { tlUpsOutletGroupEntry 3 }
|
|
|
|
tlUpsOutletGroupDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description for this outlet group."
|
|
::= { tlUpsOutletGroupEntry 4 }
|
|
|
|
tlUpsOutletGroupState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
off(1),
|
|
on(2),
|
|
mixed(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of the outlet group."
|
|
::= { tlUpsOutletGroupEntry 5 }
|
|
|
|
tlUpsOutletGroupControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turnOff(1),
|
|
turnOn(2),
|
|
cycle(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the state of every outlet associated with the group."
|
|
::= { tlUpsOutletGroupEntry 6 }
|
|
|
|
|
|
tlUpsTraps OBJECT IDENTIFIER ::= { tlUPS 2 }
|
|
|
|
tlUpsTrapAlarmEntryAddedV1 TRAP-TYPE
|
|
ENTERPRISE tlUpsTraps
|
|
VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
|
|
tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table."
|
|
--#SUMMARY "UPS Alarm: %s - %s."
|
|
--#ARGUMENTS {6, 2}
|
|
--#SEVERITY WARNING
|
|
::= 3
|
|
|
|
tlUpsTrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
|
|
tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table."
|
|
--#SUMMARY "UPS Alarm: %s - %s."
|
|
--#ARGUMENTS {6, 2}
|
|
--#SEVERITY WARNING
|
|
::= { tlUpsTraps 3 }
|
|
|
|
tlUpsTrapAlarmEntryRemovedV1 TRAP-TYPE
|
|
ENTERPRISE tlUpsTraps
|
|
VARIABLES { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
|
|
tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table."
|
|
--#SUMMARY "UPS Alarm: %s - %s."
|
|
--#ARGUMENTS {6, 2}
|
|
--#SEVERITY WARNING
|
|
::= 4
|
|
|
|
tlUpsTrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { tlUpsAlarmId, tlUpsAlarmDescr, tlUpsAlarmDetail, tlUpsAlarmDeviceId,
|
|
tlUpsAlarmDeviceName, tlUpsAlarmLocation, tlUpsAlarmGroup }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table."
|
|
--#SUMMARY "UPS Alarm: %s - %s."
|
|
--#ARGUMENTS {6, 2}
|
|
--#SEVERITY WARNING
|
|
::= { tlUpsTraps 4 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- EnviroSense Device
|
|
--------------------------------------------------------------------------
|
|
|
|
tlEnviroSense OBJECT IDENTIFIER ::= { tripplite 101 }
|
|
|
|
tlEnvEnvironment OBJECT IDENTIFIER ::= { tlEnviroSense 1 }
|
|
|
|
tlEnvTemperatureData OBJECT IDENTIFIER ::= { tlEnvEnvironment 1 }
|
|
|
|
tlEnvTemperatureC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature (C)."
|
|
::= { tlEnvTemperatureData 1 }
|
|
|
|
tlEnvTemperatureF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature (F)."
|
|
::= { tlEnvTemperatureData 2 }
|
|
|
|
tlEnvTemperatureLowLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower alarm limit for ambient temperature (F)."
|
|
::= { tlEnvTemperatureData 3 }
|
|
|
|
tlEnvTemperatureHighLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper alarm limit for ambient temperature (F)."
|
|
::= { tlEnvTemperatureData 4 }
|
|
|
|
tlEnvTemperatureInAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not temperature is in alarm."
|
|
::= { tlEnvTemperatureData 5 }
|
|
|
|
tlEnvHumidityData OBJECT IDENTIFIER ::= { tlEnvEnvironment 2 }
|
|
|
|
tlEnvHumidity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient humidity (%)."
|
|
::= { tlEnvHumidityData 1 }
|
|
|
|
tlEnvHumidityLowLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower alarm limit for ambient humidity (%)."
|
|
::= { tlEnvHumidityData 2 }
|
|
|
|
tlEnvHumidityHighLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper alarm limit for ambient humidity (%)."
|
|
::= { tlEnvHumidityData 3 }
|
|
|
|
tlEnvHumidityInAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not humidity is in alarm."
|
|
::= { tlEnvHumidityData 4 }
|
|
|
|
tlEnvContacts OBJECT IDENTIFIER ::= { tlEnviroSense 2 }
|
|
|
|
tlEnvContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TlEnvContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of contacts."
|
|
::= { tlEnvContacts 1 }
|
|
|
|
tlEnvContactEntry OBJECT-TYPE
|
|
SYNTAX TlEnvContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a particular contact."
|
|
INDEX {
|
|
tlEnvContactIndex }
|
|
::= { tlEnvContactTable 1 }
|
|
|
|
TlEnvContactEntry ::= SEQUENCE {
|
|
tlEnvContactIndex PositiveInteger,
|
|
tlEnvContactName DisplayString,
|
|
tlEnvContactStatus INTEGER,
|
|
tlEnvContactConfig INTEGER }
|
|
|
|
tlEnvContactIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table row index for the contact."
|
|
::= { tlEnvContactEntry 1 }
|
|
|
|
tlEnvContactName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name or description of the contact."
|
|
::= { tlEnvContactEntry 2 }
|
|
|
|
tlEnvContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
alarm(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of the contact."
|
|
::= { tlEnvContactEntry 3 }
|
|
|
|
tlEnvContactConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyOpen(0),
|
|
normallyClosed(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configuration of the contact."
|
|
::= { tlEnvContactEntry 4 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- KVM over IP Device
|
|
--------------------------------------------------------------------------
|
|
|
|
-- this is a 3rd party MIB structure located at { tripplite 102 }
|
|
|
|
--------------------------------------------------------------------------
|
|
-- Conformance definitions
|
|
--------------------------------------------------------------------------
|
|
|
|
tlConformance OBJECT IDENTIFIER ::= { tripplite 20 }
|
|
|
|
tlCompliances OBJECT IDENTIFIER ::= { tlConformance 1 }
|
|
|
|
tlGroups OBJECT IDENTIFIER ::= { tlConformance 2 }
|
|
|
|
tlSubsetGroups OBJECT IDENTIFIER ::= { tlGroups 1 }
|
|
|
|
tlBasicGroups OBJECT IDENTIFIER ::= { tlGroups 2 }
|
|
|
|
tlFullGroups OBJECT IDENTIFIER ::= { tlGroups 3 }
|
|
|
|
|
|
tlV11Groups OBJECT IDENTIFIER ::= { tlGroups 4 }
|
|
|
|
tlDeprecatedV11Group OBJECT-GROUP
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The tlDeprecatedV11Group defines objects which were used by
|
|
Sinetica SNMP cards on Tripplite UPSs and PowerAlert version 11.
|
|
These objects are currently only used when
|
|
tlEngineLegacySNMPSupport == true."
|
|
::= { tlV11Groups 1 }
|
|
|
|
tlDeprecatedV11NotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tlV11upsCritical,
|
|
tlV11upsWarning,
|
|
tlV11upsInformation,
|
|
tlV11upsAlarmCleared,
|
|
tlV11upsAgentStarted,
|
|
tlV11upsAgentStopped }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The tlDeprecatedV11NotificationsGroup defines PowerAlert version 11
|
|
notifications. These notifications are being deprecated, but may
|
|
still be used when tlEngineLegacySNMPSupport = true."
|
|
::= { tlV11Groups 2 }
|
|
|
|
tlObsoleteV11Group OBJECT-GROUP
|
|
OBJECTS {
|
|
upsReceptaclesNumReceptacles,
|
|
upsReceptacleIndex,
|
|
upsReceptacleType,
|
|
upsReceptacleStatus,
|
|
upsReceptacleControl,
|
|
upsEnvTemperature,
|
|
upsEnvHumidity,
|
|
upsContactIndex,
|
|
upsContactName,
|
|
upsContactStatus,
|
|
upsContactConfig }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The tlObsoleteV11Group defines objects which were used by
|
|
Sinetica SNMP cards on Tripplite UPSs. Most of these objects are obsolete."
|
|
::= { tlV11Groups 3 }
|
|
|
|
|
|
-- tlUpsCompliances OBJECT IDENTIFIER ::= { tlCompliances 1 }
|
|
--
|
|
-- tlUpsSubsetCompliance MODULE-COMPLIANCE
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Description"
|
|
-- MODULE == this module
|
|
-- MANDATORY-GROUPS {
|
|
-- groups}
|
|
--
|
|
-- OBJECT tlUpsOBJECT1
|
|
-- SYNTAX INTEGER {
|
|
-- enum1(1),
|
|
-- enum2(2)
|
|
-- }
|
|
-- DESCRIPTION
|
|
-- "Description"
|
|
--
|
|
-- OBJECT tlUpsOBJECT2
|
|
-- DESCRIPTION
|
|
-- "Description"
|
|
--
|
|
-- OBJECT tlUpsOBJECT3
|
|
-- MIN-ACCESS read-only
|
|
-- DESCRIPTION
|
|
-- "Description"
|
|
-- ::= { tlUpsCompliances 1 }
|
|
--
|
|
-- tlUpsBasicCompliance MODULE-COMPLIANCE
|
|
-- ...
|
|
-- ::= { tlUpsCompliances 2 }
|
|
--
|
|
-- tlUpsFullCompliance MODULE-COMPLIANCE
|
|
-- ...
|
|
-- ::= { tlUpsCompliances 3 }
|
|
--
|
|
-- units of conformance
|
|
--
|
|
-- summary at a glance:
|
|
-- subset basic full
|
|
--tlUpsIdentUPSSoftwareChecksum x
|
|
--tlUpsIdentSerialNum x
|
|
--tlUpsIdentID x
|
|
--
|
|
--tlUpsBatteryAge x
|
|
--tlUpsBatteryTemperatureF x
|
|
--
|
|
--tlUpsAlarm
|
|
--
|
|
--tlUpsTestDate x
|
|
--
|
|
--tlUpsWatchdogSupported x
|
|
--tlUpsWatchdogSecsBeforeReboot x
|
|
--
|
|
--tlUpsConfigBattReplDate x
|
|
--
|
|
--tlUpsLoadNumLoads x
|
|
--
|
|
--tlUpsNotificationCode x
|
|
--tlUpsNotificationDescription x
|
|
--
|
|
--tlUpsCritical x
|
|
--tlUpsWarning x
|
|
--tlUpsInformation x
|
|
--tlUpsAlarmCleared x
|
|
--tlUpsAgentStarted x
|
|
--tlUpsAgentStopped x
|
|
--
|
|
--tlUpsSubsetGroups OBJECT IDENTIFIER ::= { tlSubsetGroups 100 }
|
|
--
|
|
--tlUpsBasicGroups OBJECT IDENTIFIER ::= { tlBasicGroups 100 }
|
|
|
|
tlUpsFullGroups OBJECT IDENTIFIER ::= { tlFullGroups 100 }
|
|
|
|
tlUpsFullIdentGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsIdentUpsSoftwareChecksum,
|
|
tlUpsIdentSerialNum,
|
|
tlUpsIdentID }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullIdentGroup defines objects which are common to the Ident
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 1 }
|
|
|
|
tlUpsFullBatteryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsBatteryAge,
|
|
tlUpsTemperatureF }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullBatteryGroup defines objects which are common to the Battery
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 2 }
|
|
|
|
tlUpsFullAlarmGroup OBJECT IDENTIFIER ::= { tlUpsFullGroups 6 }
|
|
|
|
tlUpsFullAlarmObjsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsAlarmDevName,
|
|
tlUpsAlarmDevLocation,
|
|
tlUpsAlarmCategory }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullAlarmObjsGroup defines objects which are common to
|
|
the Alarm group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullAlarmGroup 1 }
|
|
|
|
--tlUpsFullAlarmsGroup NOTIFICATION-GROUP
|
|
-- NOTIFICATIONS { }
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The tlUpsFullAlarmGroup defines notifications which are
|
|
-- common to the Alarm group of fully compliant Tripplite UPS's"
|
|
-- ::= { tlUpsFullAlarmGroup 2 }
|
|
|
|
tlUpsFullTestGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsTestDate,
|
|
tlUpsTestResultsDetail }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullTestGroup defines objects which are common to the Test
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 7 }
|
|
|
|
tlUpsFullControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsWatchdogSupported,
|
|
tlUpsWatchdogSecsBeforeReboot }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullControlGroup defines objects which are common to the Control
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 8 }
|
|
|
|
tlUpsFullConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsConfigBattReplDate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullConfigGroup defines objects which are common to the Config
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 9 }
|
|
|
|
tlUpsFullOutletGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tlUpsOutletNumOutlets }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tlUpsFullOutletGroup defines objects which are common to the Outlet
|
|
group of fully compliant Tripplite UPS's"
|
|
::= { tlUpsFullGroups 10 }
|
|
|
|
--------------------------------------------------------------------------
|
|
-- Legacy (PowerAlert version 11) objects
|
|
--
|
|
-- These objects have been published in previous Tripplite MIBs and are
|
|
-- no longer supported, except where otherwise indicated.
|
|
--------------------------------------------------------------------------
|
|
|
|
trippUPS OBJECT IDENTIFIER ::= { tripplite 1 }
|
|
|
|
trippUpsReceptacles OBJECT IDENTIFIER ::= { trippUPS 1 }
|
|
|
|
upsReceptaclesNumReceptacles OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The number of available receptacles in this device.
|
|
This variable indicates the number of rows in the
|
|
receptacle table."
|
|
::= { trippUpsReceptacles 1 }
|
|
|
|
|
|
upsReceptacleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsReceptacleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A list of receptacle table entries. The number of entries
|
|
is given by the value of upsReceptaclesNumReceptacles."
|
|
::= { trippUpsReceptacles 2 }
|
|
|
|
|
|
upsReceptacleEntry OBJECT-TYPE
|
|
SYNTAX UpsReceptacleEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular receptacle."
|
|
INDEX {
|
|
upsReceptacleIndex }
|
|
::= { upsReceptacleTable 1 }
|
|
|
|
|
|
UpsReceptacleEntry ::= SEQUENCE {
|
|
upsReceptacleIndex PositiveInteger,
|
|
upsReceptacleType INTEGER,
|
|
upsReceptacleStatus INTEGER,
|
|
upsReceptacleControl INTEGER }
|
|
|
|
|
|
upsReceptacleIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The receptacle identifier."
|
|
::= { upsReceptacleEntry 1 }
|
|
|
|
|
|
upsReceptacleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
surgeOnly(1),
|
|
batteryProtected(2),
|
|
controllableBatteryProtected(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The type of receptacle."
|
|
::= { upsReceptacleEntry 2 }
|
|
|
|
|
|
upsReceptacleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
unknown(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The status of receptacle."
|
|
::= { upsReceptacleEntry 3 }
|
|
|
|
|
|
upsReceptacleControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
cycle(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Setting this object to 'on' will turn on the receptacle.
|
|
Setting this object to 'off' will turn off the receptacle.
|
|
Setting this object to 'cycle' will turn off and then turn
|
|
on the receptacle. This action will only take place if the
|
|
receptacle is controllable
|
|
(upsReceptacleType = controllableBatteryProtected(3))."
|
|
::= { upsReceptacleEntry 4 }
|
|
|
|
|
|
trippUpsTrapInfo OBJECT IDENTIFIER ::= { trippUPS 2 }
|
|
|
|
upsTrapCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A numeric code identifiying the condition that caused the trap to be sent.
|
|
If the trap number is 104 (upsAgentStarted) or 105 (upsAgentStopped), this
|
|
code will indicate whether the SNMP agent is software (1) or hardware (2)."
|
|
::= { trippUpsTrapInfo 1 }
|
|
|
|
|
|
upsTrapDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The description of the trap."
|
|
::= { trippUpsTrapInfo 2 }
|
|
|
|
|
|
trippUpsEnvironment OBJECT IDENTIFIER ::= { trippUPS 3 }
|
|
|
|
upsEnvTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The ambient temperature of the EnviroSense unit (1/10 Deg C)."
|
|
::= { trippUpsEnvironment 1 }
|
|
|
|
|
|
upsEnvHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The ambient humidity of the EnviroSense unit (% Humidity)."
|
|
::= { trippUpsEnvironment 2 }
|
|
|
|
|
|
trippUpsContacts OBJECT IDENTIFIER ::= { trippUPS 4 }
|
|
|
|
upsContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"A table of contacts attached to the EnviroSense unit."
|
|
::= { trippUpsContacts 1 }
|
|
|
|
|
|
upsContactEntry OBJECT-TYPE
|
|
SYNTAX UpsContactEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular contact."
|
|
INDEX {
|
|
upsContactIndex }
|
|
::= { upsContactTable 1 }
|
|
|
|
|
|
UpsContactEntry ::= SEQUENCE {
|
|
upsContactIndex PositiveInteger,
|
|
upsContactName DisplayString,
|
|
upsContactStatus INTEGER,
|
|
upsContactConfig INTEGER }
|
|
|
|
|
|
upsContactIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The contact identifier."
|
|
::= { upsContactEntry 1 }
|
|
|
|
|
|
upsContactName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The contact name."
|
|
::= { upsContactEntry 2 }
|
|
|
|
|
|
upsContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
normal(1),
|
|
alarm(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The current status of the contact."
|
|
::= { upsContactEntry 3 }
|
|
|
|
|
|
upsContactConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normallyClosed(0),
|
|
normallyOpen(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The default configuration of the contact."
|
|
::= { upsContactEntry 4 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- Legacy (PowerAlert version 11) traps, redefined as notifications.
|
|
--
|
|
-- These notifications define the traps used in previous Tripplite MIBs and
|
|
-- are only supported when legacy support is enabled, as indicated by
|
|
-- tlEngineLegacySNMPSupport
|
|
--------------------------------------------------------------------------
|
|
|
|
tlV11TrapsPrefix OBJECT IDENTIFIER ::= { trippUPS 0 }
|
|
|
|
tlV11upsCritical NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"UPS Critical Alarm."
|
|
::= { tlV11TrapsPrefix 100 }
|
|
|
|
|
|
tlV11upsWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"UPS Warning."
|
|
::= { tlV11TrapsPrefix 101 }
|
|
|
|
|
|
tlV11upsInformation NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"UPS Information."
|
|
::= { tlV11TrapsPrefix 102 }
|
|
|
|
|
|
tlV11upsAlarmCleared NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"UPS Alarm Cleared."
|
|
::= { tlV11TrapsPrefix 103 }
|
|
|
|
|
|
tlV11upsAgentStarted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Agent started."
|
|
::= { tlV11TrapsPrefix 104 }
|
|
|
|
|
|
tlV11upsAgentStopped NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
upsTrapCode,
|
|
upsTrapDescription}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Agent stopped."
|
|
::= { tlV11TrapsPrefix 105 }
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
-- This is an excerpt from the TRIPPUPS-MIB used for Delta SNMP cards in
|
|
-- Tripplite UPSs. It has major fundamental problems with OID collisions
|
|
-- and naming collosions, so it's commented out in its entirety. It's
|
|
-- only included for historical documentation purposes.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- BEGIN Delta SNMP MIB
|
|
--------------------------------------------------------------------------
|
|
-- ups OBJECT IDENTIFIER ::= { trippUPS 1 }
|
|
--
|
|
-- upsIdent OBJECT IDENTIFIER ::= { ups 1 }
|
|
--
|
|
-- upsBattery OBJECT IDENTIFIER ::= { ups 2 }
|
|
--
|
|
-- upsInput OBJECT IDENTIFIER ::= { ups 3 }
|
|
--
|
|
-- upsOutput OBJECT IDENTIFIER ::= { ups 4 }
|
|
--
|
|
-- upsAlarm OBJECT IDENTIFIER ::= { ups 6 }
|
|
--
|
|
-- upsWellKnownAlarms OBJECT IDENTIFIER ::= { ups 7 }
|
|
--
|
|
-- upsTest OBJECT IDENTIFIER ::= { ups 8 }
|
|
--
|
|
-- upsControl OBJECT IDENTIFIER ::= { ups 9 }
|
|
--
|
|
-- upsConfig OBJECT IDENTIFIER ::= { ups 10 }
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group are set at device initialization and remain static.
|
|
--
|
|
-- upsIdentManufacturer OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..31))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The name of the UPS manufacturer."
|
|
-- ::= { upsIdent 1 }
|
|
--
|
|
--
|
|
-- upsIdentModel OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..63))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS Model designation."
|
|
-- ::= { upsIdent 2 }
|
|
--
|
|
--
|
|
-- upsIdentUPSSoftwareVersion OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..63))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS Firmware software version(s). This variable
|
|
-- may or may not have the same value as
|
|
-- upsIdentAgentSoftwareVersion in some implementations."
|
|
-- ::= { upsIdent 3 }
|
|
--
|
|
--
|
|
-- upsIdentAgentSoftwareVersion OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..63))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS agent software version. This variable may or
|
|
-- may not have the same value as
|
|
-- upsIdentUPSSoftwareVersion in some implementations."
|
|
-- ::= { upsIdent 4 }
|
|
--
|
|
--
|
|
-- upsIdentName OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..63))
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A string identifying the UPS. This object should be
|
|
-- set by the administrator."
|
|
-- ::= { upsIdent 5 }
|
|
--
|
|
--
|
|
-- upsIdentAttachedDevices OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..63))
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A string identifying the devices attached to the
|
|
-- output(s) of the UPS. This object should be set by
|
|
-- the administrator."
|
|
-- ::= { upsIdent 6 }
|
|
--
|
|
--
|
|
-- The Battery group.
|
|
-- Implementation of this group is mandatory for all systems.
|
|
--
|
|
-- upsBatteryStatus OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- unknown(1),
|
|
-- batteryNormal(2),
|
|
-- batteryLow(3),
|
|
-- batteryDepleted(4) }
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The indication of the capacity remaining in the UPS
|
|
-- system's batteries. A value of batteryNormal
|
|
-- indicates that the batteries are fully charged. A
|
|
-- value of batteryLow indicates that the remaining battery
|
|
-- run-time is less than or equal to
|
|
-- upsConfigMinutesRemaining. A value of batteryDepleted
|
|
-- indicates that the UPS will be unable to sustain the
|
|
-- present load when and if the utility power is lost."
|
|
-- ::= { upsBattery 1 }
|
|
--
|
|
--
|
|
-- upsSecondsOnBattery OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the unit is on battery power, the elapsed time
|
|
-- since the UPS last switched to battery power, or the
|
|
-- time since the network management subsystem was last
|
|
-- restarted, whichever is less. Zero shall be returned
|
|
-- if the unit is not on battery power. UNITS - seconds"
|
|
-- ::= { upsBattery 2 }
|
|
--
|
|
--
|
|
-- upsEstimatedMinutesRemaining OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "An estimate of the time to battery charge depletion
|
|
-- under the present load conditions if the utility power
|
|
-- were to be lost and remain off. UNITS - minutes"
|
|
-- ::= { upsBattery 3 }
|
|
--
|
|
--
|
|
-- upsBatteryChargeRemaining OBJECT-TYPE
|
|
-- SYNTAX INTEGER (0..100)
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The estimate of the battery charge remaining expressed
|
|
-- as a percent of full charge."
|
|
-- ::= { upsBattery 4 }
|
|
--
|
|
--
|
|
-- upsBatteryVoltage OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The magnitude of the present battery voltage. UNITS 0.1 Volt DC."
|
|
-- ::= { upsBattery 5 }
|
|
--
|
|
--
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsBatteryCurrent MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsBattery 6 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--
|
|
-- upsBatteryTemperature OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The ambient temperature at or near the UPS Battery.
|
|
-- UNITS degrees Centigrade"
|
|
-- ::= { upsBattery 7 }
|
|
--
|
|
--
|
|
-- the table group has one attribute of its own - the number of rows in the
|
|
-- contained table. It also contains the table of names.
|
|
-- The Input group.
|
|
-- Implementation of this group is mandatory for all systems.
|
|
--
|
|
-- upsInputFrequency OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present input frequency. UNITS 0.1 Hertz"
|
|
-- ::= { upsInput 1 }
|
|
--
|
|
--
|
|
-- upsInputLineBads OBJECT-TYPE
|
|
-- SYNTAX Counter
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A count of the number of times the input entered an
|
|
-- out-of-tolerance condition as defined by the manufacturer."
|
|
-- ::= { upsInput 2 }
|
|
--
|
|
--
|
|
-- upsInputNumLines OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The number of input lines utilized in this device.
|
|
-- This variable indicates the number of rows in the input table."
|
|
-- ::= { upsInput 3 }
|
|
--
|
|
--
|
|
-- upsInputVolt OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The magnitude of the present input voltage.
|
|
-- UNITS RMS Volts"
|
|
-- ::= { upsInput 4 }
|
|
--
|
|
--
|
|
-- upsInputTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF UpsInputEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of input table entries. The number of entries
|
|
-- is given by the value of upsInputNumLines."
|
|
-- ::= { upsInput 5 }
|
|
--
|
|
--
|
|
-- upsInputEntry OBJECT-TYPE
|
|
-- SYNTAX UpsInputEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "An entry containing information applicable to a
|
|
-- particular input line."
|
|
-- INDEX {
|
|
-- upsInputLineIndex }
|
|
-- ::= { upsInputTable 1 }
|
|
--
|
|
--
|
|
-- UpsInputEntry ::= SEQUENCE {
|
|
-- upsInputLineIndex INTEGER,
|
|
-- upsInputVoltage INTEGER }
|
|
--
|
|
--
|
|
-- upsInputLineIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The input line identifier."
|
|
-- ::= { upsInputEntry 1 }
|
|
--
|
|
--
|
|
-- upsInputVoltage OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The magnitude of the present input voltage.
|
|
-- UNITS RMS Volts"
|
|
-- ::= { upsInputEntry 2 }
|
|
--
|
|
--
|
|
-- The Output group.
|
|
-- Implementation of this group is mandatory for all systems.
|
|
--
|
|
-- upsOutputSource OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- other(1),
|
|
-- none(2),
|
|
-- normal(3),
|
|
-- bypass(4),
|
|
-- battery(5),
|
|
-- booster(6),
|
|
-- reducer(7) }
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present source of output power."
|
|
-- ::= { upsOutput 1 }
|
|
--
|
|
--
|
|
-- upsOutputFrequency OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present output frequency.
|
|
-- UNITS 0.1 Hertz"
|
|
-- ::= { upsOutput 2 }
|
|
--
|
|
--
|
|
-- upsOutputNumLines OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The number of output lines utilized in this device.
|
|
-- This variable indicates the number of rows in the output table."
|
|
-- ::= { upsOutput 3 }
|
|
--
|
|
--
|
|
-- upsOutputPercLoad OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The percentage of true power capacity presently being used.
|
|
-- UNITS percent"
|
|
-- ::= { upsOutput 4 }
|
|
--
|
|
--
|
|
-- upsOutputTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF UpsOutputEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of output table entries. The number of
|
|
-- entries is given by the value of upsOutputNumLines."
|
|
-- ::= { upsOutput 5 }
|
|
--
|
|
--
|
|
-- upsOutputEntry OBJECT-TYPE
|
|
-- SYNTAX UpsOutputEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "An entry containing information applicable to a
|
|
-- particular output line."
|
|
-- INDEX {
|
|
-- upsOutputLineIndex }
|
|
-- ::= { upsOutputTable 1 }
|
|
--
|
|
--
|
|
-- UpsOutputEntry ::= SEQUENCE {
|
|
-- upsOutputLineIndex INTEGER,
|
|
-- upsOutputVoltage INTEGER,
|
|
-- upsOutputCurrent INTEGER,
|
|
-- upsOutputPower INTEGER,
|
|
-- upsOutputPercentLoad INTEGER }
|
|
--
|
|
--
|
|
-- upsOutputLineIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The output line identifier."
|
|
-- ::= { upsOutputEntry 1 }
|
|
--
|
|
--
|
|
-- upsOutputVoltage OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present output voltage.
|
|
-- UNITS RMS Volts"
|
|
-- ::= { upsOutputEntry 2 }
|
|
--
|
|
--
|
|
-- upsOutputCurrent OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present output mandatory.
|
|
-- UNITS 0.1 Amp"
|
|
-- ::= { upsOutputEntry 3 }
|
|
--
|
|
--
|
|
-- upsOutputPower OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present output true power.
|
|
-- UNITS Watts"
|
|
-- ::= { upsOutputEntry 4 }
|
|
--
|
|
--
|
|
-- upsOutputPercentLoad OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The percentage of true power capacity presently being used.
|
|
-- UNITS percent"
|
|
-- ::= { upsOutputEntry 5 }
|
|
--
|
|
--
|
|
-- Alarm Group
|
|
--
|
|
-- upsAlarmsPresent OBJECT-TYPE
|
|
-- SYNTAX Gauge
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The present number of active alarm conditions."
|
|
-- ::= { upsAlarm 1 }
|
|
--
|
|
--
|
|
-- upsAlarmID OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- upsAlarmBatteryBad(1),
|
|
-- upsAlarmOnBattery(2),
|
|
-- upsAlarmLowBattery(3),
|
|
-- upsAlarmDepletedBattery(4),
|
|
-- upsAlarmTempBad(5),
|
|
-- upsAlarmOutputOverload(6),
|
|
-- upsAlarmOutputOffAsRequested(7),
|
|
-- upsAlarmOutputOff(8),
|
|
-- upsAlarmDiagnosticTestFailed(9),
|
|
-- upsAlarmCommunicationsLost(10),
|
|
-- upsAlarmShutdownPending(11),
|
|
-- upsAlarmShutdownImminent(12),
|
|
-- upsAlarmTestInProgress(13) }
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A unique identifier for an alarm condition. This
|
|
-- value must remain constant."
|
|
-- ::= { upsAlarm 2 }
|
|
--
|
|
--
|
|
-- upsAlarmDESCR OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..31))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A reference to an alarm description object. The
|
|
-- object references should not be accessible, but rather
|
|
-- be used to provide a unique description of the alarm
|
|
-- condition."
|
|
-- ::= { upsAlarm 3 }
|
|
--
|
|
--
|
|
-- upsAlarmTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF UpsAlarmEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of alarm table entries. The table consists of
|
|
-- zero, one, or may rows at any moment, depending upon
|
|
-- the number of alarm conditions in effect. The table
|
|
-- is initially empty at agent startup. The agent
|
|
-- creates a row in the table each time a condition is
|
|
-- detected and deletes that row when that condition no
|
|
-- longer pertains. The agent creates the first row with
|
|
-- upsAlarmId equal to 1, and increments the value fo
|
|
-- upsAlarmId each time a new row is created, wrapping to
|
|
-- the first free value greater than or equal to 1 when
|
|
-- the maximum value of upsAlarmId would otherwise be
|
|
-- exceeded. Consequently, after multiple operations,
|
|
-- the table may become sparse, e.g., containing entries
|
|
-- for rows 95, 100, 101, and 203 and the entries are in
|
|
-- chronological order until upsAlarmId wraps.
|
|
--
|
|
-- Alarms are named by and OBJECT IDENTIFIER,
|
|
-- upsAlarmDescr, to allow a single table to reflect well
|
|
-- known alarms plus alarms defined by a particular
|
|
-- implementation, i.e., as documented in the private
|
|
-- enterprise MIB definition for the device. No two rows
|
|
-- will have the same value of upsAlarmDescr, since
|
|
-- alarms define conditions. In order to meet this
|
|
-- requirement, care should be take in the definition of
|
|
-- the number of active rows in the table at any given
|
|
-- time is reflected by the value fo upsAlarms."
|
|
-- ::= { upsAlarm 4 }
|
|
--
|
|
--
|
|
-- upsAlarmEntry OBJECT-TYPE
|
|
-- SYNTAX UpsAlarmEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "An entry containing information applicable to a
|
|
-- particular alarm."
|
|
-- INDEX {
|
|
-- upsAlarmId }
|
|
-- ::= { upsAlarmTable 1 }
|
|
--
|
|
--
|
|
-- UpsAlarmEntry ::= SEQUENCE {
|
|
-- upsAlarmId INTEGER,
|
|
-- upsAlarmDescr DisplayString,
|
|
-- upsAlarmTime TimeTicks }
|
|
--
|
|
--
|
|
-- upsAlarmId OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A unique identifier for an alarm condition. This
|
|
-- value must remain constant."
|
|
-- ::= { upsAlarmEntry 1 }
|
|
--
|
|
--
|
|
-- upsAlarmDescr OBJECT-TYPE
|
|
-- SYNTAX DisplayString (SIZE (0..31))
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A reference to an alarm description object. The
|
|
-- object references should not be accessible, but rather
|
|
-- be used to provide a unique description of the alarm
|
|
-- condition."
|
|
-- ::= { upsAlarmEntry 2 }
|
|
--
|
|
--
|
|
-- upsAlarmTime OBJECT-TYPE
|
|
-- SYNTAX TimeTicks
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The value of sysUpTime when the alarm condition was
|
|
-- detected. If the alarm condition was detected at the
|
|
-- time of agent startup and presumable existed before
|
|
-- agent startup, the value of upsAlarmTime shall equal
|
|
-- 0."
|
|
-- ::= { upsAlarmEntry 3 }
|
|
--
|
|
--
|
|
-- upsAlarmBatteryBad OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "One or more batteries have been determined to require
|
|
-- replacement."
|
|
-- ::= { upsWellKnownAlarms 1 }
|
|
--
|
|
--
|
|
-- upsAlarmOnBattery OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS is drawing power from the batteries."
|
|
-- ::= { upsWellKnownAlarms 2 }
|
|
--
|
|
--
|
|
-- upsAlarmLowBattery OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The remaining battery run-time is less than or equal
|
|
-- to upsConfigMinutesRemaining."
|
|
-- ::= { upsWellKnownAlarms 3 }
|
|
--
|
|
--
|
|
-- upsAlarmDepletedBattery OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS will be unable to sustain the present load
|
|
-- when and if the utility power is lost."
|
|
-- ::= { upsWellKnownAlarms 4 }
|
|
--
|
|
--
|
|
-- upsAlarmTempBad OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A temperature is out of tolerance."
|
|
-- ::= { upsWellKnownAlarms 5 }
|
|
--
|
|
--
|
|
-- upsAlarmOutputOverload OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The output load exceeds the UPS output capacity."
|
|
-- ::= { upsWellKnownAlarms 6 }
|
|
--
|
|
--
|
|
-- upsAlarmOutputOffAsRequested OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS has shutdown as commanded, i.e., the output is off."
|
|
-- ::= { upsWellKnownAlarms 7 }
|
|
--
|
|
--
|
|
-- upsAlarmUpsOutputOff OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The UPS is in the off state."
|
|
-- ::= { upsWellKnownAlarms 8 }
|
|
--
|
|
--
|
|
-- upsAlarmDiagnosticTestFailed OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The result of the last diagnostic test indicates a
|
|
-- failure."
|
|
-- ::= { upsWellKnownAlarms 9 }
|
|
--
|
|
--
|
|
-- upsAlarmCommunicationsLost OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A problem has been encountered in the
|
|
-- communications between the agent and the UPS."
|
|
-- ::= { upsWellKnownAlarms 10 }
|
|
--
|
|
--
|
|
-- upsAlarmShutdownPending OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A upsShutdownAfterDelay countdown is underway."
|
|
-- ::= { upsWellKnownAlarms 11 }
|
|
--
|
|
--
|
|
-- upsAlarmShutdownImminent OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A upsShutdownAfterDelay countdown is underway."
|
|
-- ::= { upsWellKnownAlarms 12 }
|
|
--
|
|
--
|
|
-- upsAlarmTestInProgress OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A upsShutdownAfterDelay countdown is underway."
|
|
-- ::= { upsWellKnownAlarms 13 }
|
|
--
|
|
-- Test Group
|
|
--
|
|
-- upsTestId OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- noTestsInitiated(1),
|
|
-- abortTestInProgress(2),
|
|
-- generalSystemsTest(3),
|
|
-- checkBatteryTest(4),
|
|
-- deepBatteryCalibration(5) }
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The test named by an OBJECT IDENTIFIER which
|
|
-- allows a standard mechanism for the initiation of
|
|
-- test, including the well known tests identified in
|
|
-- this document as well as those introduced by a
|
|
-- particular implementation, i.e., as
|
|
-- documented in the private enterprise MIB definition
|
|
-- for the device.
|
|
--
|
|
-- Setting this variable initiates the named test. Sets
|
|
-- to this variable require the presence of
|
|
-- upsTestSpinLock in the same SNMP message.
|
|
--
|
|
-- The set request will be rejected with an appropriate
|
|
-- error message if the requested test cannot be
|
|
-- performed, including attempts to start a test when
|
|
-- another test is already in progress. Tests in
|
|
-- progress may be aborted by setting this variable to
|
|
-- upsTestAbortTestInProgress.
|
|
--
|
|
-- Read operations return the value of the name of the
|
|
-- test in progress if a test is in progress or the name
|
|
-- of the last test performed if no test is in progress,
|
|
-- unless no test has bee run, in which case the well
|
|
-- known value upsTestNoTestsInitiated is returned."
|
|
-- ::= { upsTest 1 }
|
|
--
|
|
--
|
|
-- upsTestResultsSummary OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- donePass(1),
|
|
-- doneWarning(2),
|
|
-- doneError(3),
|
|
-- aborted(4),
|
|
-- inProgress(5),
|
|
-- noTestsInitiated(6) }
|
|
-- ACCESS read-only
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "The results of the mandatory or last UPS diagnostics
|
|
-- test performed. The values for donePass(1),
|
|
-- doneWarning(2), and doneError(3) are self-documenting.
|
|
-- The value aborted(4) is returned for tests which are
|
|
-- aborted by setting the value of upsTestId to
|
|
-- upsTestAbortTestInProgress. Tests which have not yet
|
|
-- concluded are indicated by inProgress(5). The value
|
|
-- noTestsInitiated(4) indicates that no previous test
|
|
-- results are available, such as in the case when no
|
|
-- tests have been run since the last reinitialization of
|
|
-- the network management subsystem and the system has no
|
|
-- provision for non-volatile storage of test results."
|
|
-- ::= { upsTest 2 }
|
|
--
|
|
--
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsTestResultsDetail MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsTest 3 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsTestStartTime MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsTest 4 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
-- Control Group
|
|
--
|
|
-- upsShutdownType OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- output(1),
|
|
-- system(2) }
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Setting this object will start the output after the
|
|
-- indicated number of seconds. Setting this object to 0
|
|
-- will cause the UPS to start the output immediately.
|
|
-- If the output is already on at the time the delay has
|
|
-- counted down, nothing will happen."
|
|
-- ::= { upsControl 1 }
|
|
--
|
|
--
|
|
-- upsShutdownAfterDelay OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Setting this object will shutdown (i.e., turn off)
|
|
-- either the UPS output or the UPS system (as determined
|
|
-- by the value of upsShhutdownType at the time of
|
|
-- shutdown) after the indicated number of seconds, or
|
|
-- less if the UPS batteries become depleted. Setting
|
|
-- this object to 0 will cause the shutdown to occur
|
|
-- immediately. Setting this object to -1 will abort the
|
|
-- countdown. If the system is already in the desired
|
|
-- state at the time the countdown reaches 0, then
|
|
-- nothing will happen. That is, there is no additional
|
|
-- action at that time if upsShutdownType = system and
|
|
-- the system is already off. Similarly, there is no
|
|
-- additional action at that time if upsShutdownType =
|
|
-- output and the output is already off. When read,
|
|
-- upsShutdownAfterDelay will return the number of
|
|
-- seconds remaining until shutdown, or -1 if no shutdown
|
|
-- countdown is in effect. On some systems, if the agent
|
|
-- is restarted while a shutdown countdown is in effect,
|
|
-- the countdown may be aborted. Sets to this object
|
|
-- override any upsShutdownAfterDelay already in effect.
|
|
-- UNITS seconds"
|
|
-- ::= { upsControl 2 }
|
|
--
|
|
--
|
|
-- upsStartupAfterDelay OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Setting this object will start the output after the
|
|
-- indicated number of seconds, includeing starting the
|
|
-- UPS, if necessary. Setting this object to 0 will
|
|
-- cause the start to occur immediately. Setting this
|
|
-- object to -1 will abort the countdown. If the output
|
|
-- is already on at the time the countdown reaches 0,
|
|
-- nothing will happen. Sets to this object
|
|
-- override the effect of any upsStartupAfterDelay
|
|
-- countdown or upsRebootDuration countdown in progress.
|
|
-- When read, upsStartupAfterDelay will return the number
|
|
-- of seconds until start, or -1 if no startup
|
|
-- countdown is in effect. If the countdown expires
|
|
-- during a utility failure, the startup shall depend
|
|
-- upon the value of upsAutoRestart at that time. On
|
|
-- some systems, if the agent is restarted while a
|
|
-- startup countdown is in effect, the countdown is
|
|
-- aborted.
|
|
-- UNITS seconds"
|
|
-- ::= { upsControl 3 }
|
|
--
|
|
--
|
|
-- upsRebootDuration OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Setting this object will immediately shutdown (i.e.,
|
|
-- turn off) either the UPS output or the UPS system (as
|
|
-- determined by the value of the upsShutdownType at the time
|
|
-- of shutdown) for a period equal to the indicated
|
|
-- number of seconds, after which time the output will be
|
|
-- started, including starting the UPS, if necessary. If
|
|
-- the number of seconds required to perform the request
|
|
-- is greater than the requested duration, then the
|
|
-- requested shutdown and startup cycle shall be
|
|
-- performed in the minimum time possible, but in no case
|
|
-- shall this require more than the requested duration
|
|
-- plus 60 seconds. When read, upsRebootDuration shall
|
|
-- return the number of seconds remaining in the
|
|
-- countdown, or -1 if no countdown is in progress. If
|
|
-- the startup should occur during a utility failure, the
|
|
-- startup shall depend on the value of upsAutoRestart
|
|
-- at that time.
|
|
-- UNITS seconds"
|
|
-- ::= { upsControl 4 }
|
|
--
|
|
--
|
|
-- upsAutoRestart OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- on(1),
|
|
-- off(2) }
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "Setting this object to 'on' will cause the UPS system
|
|
-- to restart after a shutdown if/when utility power is present."
|
|
-- ::= { upsControl 5 }
|
|
--
|
|
--
|
|
-- upsConfig group
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigInputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 1 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsInputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 2 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigOutputVoltage MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 3 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigOutputFreq MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 4 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigOutputVA MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 5 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigOutputPower MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 6 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigLowBattTime MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 7 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigAudibleStatus MIB variable removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, {upsConfig 8 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigLowVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on
|
|
-- 4/24/95. To conform with older versions of this MIB, {upsConfig 9 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsConfigHighVoltageTransferPoint MIB variable removed by Dave Cole (SEC) on
|
|
-- 4/24/95. To conform with older versions of this MIB, {upsConfig 10 } is reserved.
|
|
--------------------------------------------------------------------------
|
|
-- upsConfigInputVoltageHigh OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the value of the input voltage (in Volts) exceeds this value, a
|
|
-- utilityVoltageHigh trap will be triggered."
|
|
-- ::= { upsConfig 11 }
|
|
--
|
|
--
|
|
-- upsConfigInputVoltageLow OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the value of the input voltage (in Volts) falls below this value, a
|
|
-- utilityVoltageLow trap will be triggered."
|
|
-- ::= { upsConfig 12 }
|
|
--
|
|
--
|
|
-- upsConfigOutputPercLoadHigh OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the value of the output percent load exceeds this value, a upsOverload trap
|
|
-- will be triggered."
|
|
-- ::= { upsConfig 13 }
|
|
--
|
|
--
|
|
-- upsConfigBatteryPercLow OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the value of the battery percent capacity falls below this value, a lowBattery
|
|
-- trap will be triggered."
|
|
-- ::= { upsConfig 14 }
|
|
--
|
|
--
|
|
-- upsConfigBatteryTemperatureHigh OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-write
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "If the value of the battery temperature exceeds this value, a
|
|
-- batteryTemperatureHigh trap will be triggered."
|
|
-- ::= { upsConfig 15 }
|
|
--
|
|
--
|
|
--
|
|
-- Traps
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsOnBattery trap modified by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, trap 1 is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsTestCompleted trap removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, trap 2 is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsAlarmEntryAdded trap removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, trap 3 is reserved.
|
|
--------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------
|
|
-- Note : upsAlarmEntryDeleted trap removed by Dave Cole (SEC) on 4/24/95
|
|
-- To conform with older versions of this MIB, trap 4 is reserved.
|
|
--------------------------------------------------------------------------
|
|
--
|
|
-- upsOnBattery TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- VARIABLES {
|
|
-- upsIdentAttachedDevices,
|
|
-- upsEstimatedMinutesRemaining}
|
|
-- DESCRIPTION
|
|
-- "The UPS is on battery."
|
|
-- ::= 5
|
|
--
|
|
--
|
|
-- powerRestored TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "Utility power has been restored."
|
|
-- ::= 6
|
|
--
|
|
--
|
|
-- lowBattery TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS batteries are low and will soon be exhausted."
|
|
-- ::= 7
|
|
--
|
|
--
|
|
-- returnFromLowBattery TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS has returned from a low battery condition."
|
|
-- ::= 8
|
|
--
|
|
--
|
|
-- communicationEstablished TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "Communication with the UPS has been established. This trap will be sent
|
|
-- each time there is a transition from a power off condition to a power on condition."
|
|
-- ::= 9
|
|
--
|
|
--
|
|
-- communicationLost TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "Communication with the UPS has been lost."
|
|
-- ::= 10
|
|
--
|
|
--
|
|
-- upsOverload TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS has sensed a load greater than the value of the
|
|
-- upsConfigOutputPercLoadHigh MIB variable."
|
|
-- ::= 11
|
|
--
|
|
--
|
|
-- upsDiagnosticsFailed TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS failed its self-test."
|
|
-- ::= 12
|
|
--
|
|
--
|
|
-- upsDiagnosticsPassed TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS passed its internal self-test."
|
|
-- ::= 13
|
|
--
|
|
--
|
|
-- utilityVoltageHigh TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS input voltage greater than or equal to the value of
|
|
-- the upsConfigInputVoltageHigh MIB variable."
|
|
-- ::= 14
|
|
--
|
|
--
|
|
-- utilityVoltageLow TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS input voltage is less than or equal to the value of
|
|
-- the upsConfigInputVoltageLow MIB variable."
|
|
-- ::= 15
|
|
--
|
|
--
|
|
-- utilityVoltageReturnToNormal TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS has returned from a utility voltage high or low condition."
|
|
-- ::= 16
|
|
--
|
|
--
|
|
-- batteryTemperatureHigh TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS battery temperature has exceeded the value of the
|
|
-- upsConfigBatteryTemperatureHigh MIB variable."
|
|
-- ::= 17
|
|
--
|
|
--
|
|
-- shutdownPending TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "A UPS shutdown countdown is underway."
|
|
-- ::= 18
|
|
--
|
|
--
|
|
-- upsSleeping TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The output of the UPS has been turned off."
|
|
-- ::= 19
|
|
--
|
|
--
|
|
-- upsWokeup TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The output of the UPS has been turned on."
|
|
-- ::= 20
|
|
--
|
|
--
|
|
-- upsBatteryNeedsReplacement TRAP-TYPE
|
|
-- ENTERPRISE tripplite
|
|
-- DESCRIPTION
|
|
-- "The UPS battery needs to be replaced."
|
|
-- ::= 21
|
|
--------------------------------------------------------------------------
|
|
-- END Delta SNMP MIB
|
|
--------------------------------------------------------------------------
|
|
|
|
|
|
END
|