mibs/MIBS/procera/PACKETLOGIC-HW-SFP-MIB
2023-12-05 12:25:34 +01:00

152 lines
3.0 KiB
Plaintext

PACKETLOGIC-HW-SFP-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE,
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64,
Unsigned32, TimeTicks FROM SNMPv2-SMI
packetlogic2 FROM PACKETLOGIC-MIB
hw FROM PACKETLOGIC-HW-MIB
DisplayString, DateAndTime FROM SNMPv2-TC
CounterBasedGauge64 FROM HCNUM-TC;
sfp MODULE-IDENTITY
LAST-UPDATED "201909121500Z"
ORGANIZATION "Procera Networks, Inc."
CONTACT-INFO "support@proceranetworks.com"
DESCRIPTION "MIB For SFP and SFP+ Optical Transceivers"
REVISION "201909121500Z"
DESCRIPTION " Latest version at the revision date for version GET VERSION HERE"
::={hw 4}
PortEntry ::= SEQUENCE {
portName DisplayString,
portCompatibility DisplayString,
portVendorName DisplayString,
portVendorOUI DisplayString,
portVendorPN DisplayString,
portVendorRevisionLevel DisplayString,
checksumBaseFields DisplayString,
portVendorSN DisplayString,
portVendorDateCode DisplayString,
checksumExtendedFields DisplayString,
portEntryIndex Integer32
}
ports OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
::= {sfp 1}
portEntry OBJECT-TYPE
SYNTAX PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
INDEX { portEntryIndex }
::= {ports 1}
portEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Row Index for Conceptual Table"
::={portEntry 999}
portName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Port Name"
::={portEntry 1}
portCompatibility OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Electronic or optical compatibility"
::={portEntry 2}
portVendorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SFP vendor name"
::={portEntry 3}
portVendorOUI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SFP vendor IEEE company ID"
::={portEntry 4}
portVendorPN OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Part number provided by SFP vendor"
::={portEntry 5}
portVendorRevisionLevel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Revision level for part number provided by vendor"
::={portEntry 6}
checksumBaseFields OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Check code for Base ID Fields"
::={portEntry 7}
portVendorSN OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number provided by vendor"
::={portEntry 8}
portVendorDateCode OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vendor manufacturing date code"
::={portEntry 9}
checksumExtendedFields OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Check code for the Extended ID Fields"
::={portEntry 10}
END