mibs/MIBS/procera/PACKETLOGIC-NIC-MIB
2023-12-05 12:25:34 +01:00

198 lines
3.6 KiB
Plaintext

PACKETLOGIC-NIC-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE,
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64,
Unsigned32, TimeTicks FROM SNMPv2-SMI
packetlogic2 FROM PACKETLOGIC-MIB
hw FROM PACKETLOGIC-HW-MIB
DisplayString, DateAndTime FROM SNMPv2-TC
CounterBasedGauge64 FROM HCNUM-TC;
nic MODULE-IDENTITY
LAST-UPDATED "201909121500Z"
ORGANIZATION "Procera Networks, Inc."
CONTACT-INFO "support@proceranetworks.com"
DESCRIPTION "MIB for PacketLogic2 Network Interface Modules"
REVISION "201909121500Z"
DESCRIPTION " Latest version at the revision date for version GET VERSION HERE"
::={hw 2}
SlotEntry ::= SEQUENCE {
slotLabel DisplayString,
slotState DisplayString,
slotBypass DisplayString,
slotChannels DisplayString,
slotInterface DisplayString,
slotPartNo DisplayString,
slotPorts DisplayString,
slotSpeed DisplayString,
slotEntryIndex Integer32
}
slots OBJECT-TYPE
SYNTAX SEQUENCE OF SlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
::= {nic 1}
slotEntry OBJECT-TYPE
SYNTAX SlotEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
INDEX { slotEntryIndex }
::= {slots 1}
slotEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Row Index for Conceptual Table"
::={slotEntry 999}
ChannelEntry ::= SEQUENCE {
channelLocation DisplayString,
channelLabel DisplayString,
channelSlot DisplayString,
channelEntryIndex Integer32
}
channels OBJECT-TYPE
SYNTAX SEQUENCE OF ChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
::= {nic 2}
channelEntry OBJECT-TYPE
SYNTAX ChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Conceptual Table"
INDEX { channelEntryIndex }
::= {channels 1}
channelEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Unique Row Index for Conceptual Table"
::={channelEntry 999}
slotLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Label"
::={slotEntry 1}
slotState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot State"
::={slotEntry 2}
slotBypass OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Bypass Support"
::={slotEntry 3}
slotChannels OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Channels"
::={slotEntry 4}
slotInterface OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Interface Type"
::={slotEntry 5}
slotPartNo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Part Number"
::={slotEntry 6}
slotPorts OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Ports"
::={slotEntry 7}
slotSpeed OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Speed"
::={slotEntry 8}
channelLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Channel Location"
::={channelEntry 1}
channelLabel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Channel Label"
::={channelEntry 2}
channelSlot OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Slot Label"
::={channelEntry 3}
totalThroughput OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total potential throughput based on capacity of installed NICs (Gb/s)"
::={nic 3}
END