mibs/MIBS/protelevision/PT3080-MIB
2023-12-05 12:25:34 +01:00

9499 lines
315 KiB
Plaintext

PT3080-MIB DEFINITIONS ::= BEGIN
IMPORTS
pt FROM PT-MIB
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP, AGENT-CAPABILITIES FROM SNMPv2-CONF
DateAndTime, DisplayString FROM SNMPv2-TC;
pt3080 MODULE-IDENTITY
LAST-UPDATED "201506220940Z"
ORGANIZATION "ProTelevision Technologies A/S, Denmark"
CONTACT-INFO
"Contact:
Web: http://www.protelevision.com
Address: Valhoejs Alle 176, DK-2610 Roedovre, Denmark
Telephone: +45 44700000
Fax: +45 44700001"
DESCRIPTION
"This is the MIB file of PT3080 DVB-T/H Modulator.
Copyright (c) 2008-2015 Protelevision Technologies A/S.
All rights reserved.
Reproduction of this document is authorized on the condition
that the foregoing copyright notice is included."
REVISION
"201506220940Z"
DESCRIPTION
"SWPROTELEVISION_P3_1_02_157 build 1441106393"
::= { pt 3080 }
pt3080System OBJECT IDENTIFIER ::= { pt3080 1 }
pt3080Mode OBJECT IDENTIFIER ::= { pt3080 2 }
pt3080Input OBJECT IDENTIFIER ::= { pt3080 3 }
pt3080Output OBJECT IDENTIFIER ::= { pt3080 4 }
pt3080Gps OBJECT IDENTIFIER ::= { pt3080 7 }
pt3080TSoIP OBJECT IDENTIFIER ::= { pt3080 10 }
pt3080Monitor OBJECT IDENTIFIER ::= { pt3080 12 }
pt3080Test OBJECT IDENTIFIER ::= { pt3080 13 }
pt3080Alarm OBJECT IDENTIFIER ::= { pt3080 14 }
pt3080Preset OBJECT IDENTIFIER ::= { pt3080 15 }
pt3080Eventlog OBJECT IDENTIFIER ::= { pt3080 16 }
pt3080Comms OBJECT IDENTIFIER ::= { pt3080 17 }
pt3080Demodulator OBJECT IDENTIFIER ::= { pt3080 24 }
pt3080Precorrector OBJECT IDENTIFIER ::= { pt3080 25 }
pt3080ASI OBJECT IDENTIFIER ::= { pt3080 30 }
pt3080Reception OBJECT IDENTIFIER ::= { pt3080 26 }
pt3080Backplane OBJECT IDENTIFIER ::= { pt3080 27 }
pt3080Notifs OBJECT IDENTIFIER ::= { pt3080 64 }
pt3080Conformance OBJECT IDENTIFIER ::= { pt3080 100 }
pt3080Compliances OBJECT IDENTIFIER ::= { pt3080Conformance 1 }
--
--
-- pt3080 System sub-tree
--
pt3080SystemInstrumentFW1Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW1 revision"
::= { pt3080System 7 }
pt3080SystemInstrumentFW1RevBL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW1 BL revision"
::= { pt3080System 8 }
pt3080SystemInstrumentFW2Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW2 revision"
::= { pt3080System 9 }
pt3080SystemInstrumentFW2RevBL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW2 BL revision"
::= { pt3080System 10 }
pt3080SystemInstrumentFW3Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW3 revision"
::= { pt3080System 11 }
pt3080SystemInstrumentFW4Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW4 revision"
::= { pt3080System 12 }
pt3080SystemInstrumentPCBRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument PCB revision"
::= { pt3080System 13 }
pt3080SystemInstrumentCalibrationRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Calibration revision"
::= { pt3080System 14 }
pt3080SystemInstrumentCalibrationDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Calibration date"
::= { pt3080System 15 }
pt3080SystemReboot OBJECT-TYPE
SYNTAX INTEGER { keeprunning(0), sameimage(1), otherimage(2), image0(3), image1(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force a reboot of the device on the designated image now."
::= { pt3080System 16 }
pt3080SystemRebootDefaultConfig OBJECT-TYPE
SYNTAX INTEGER { keeprunning(0), reboot(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restore all parameters to factory default and reboot the device on the same image."
::= { pt3080System 19 }
pt3080SystemDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current date/time in local timezone of the device.
Format is YYYY MM DD HH MM SS."
::= { pt3080System 22 }
pt3080SystemImage0Version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image 0 version string."
::= { pt3080System 24 }
pt3080SystemImage0InstalledDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time image 0 was installed."
::= { pt3080System 25 }
pt3080SystemImage1version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image 1 version string."
::= { pt3080System 26 }
pt3080SystemImage1InstalledDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time image 0 was installed."
::= { pt3080System 27 }
pt3080SystemServiceLED OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control the Service LED on frontpanel."
::= { pt3080System 28 }
pt3080SystemLanguage OBJECT-TYPE
SYNTAX INTEGER { c(0), da-dk(1), ru-ru(2), es-es(3), pt-br(4), it-it(5), de-de(6), fr-fr(7) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which language is used on web and facia. Change requires
reboot."
::= { pt3080System 33 }
pt3080SystemType OBJECT-TYPE
SYNTAX INTEGER { modulator(0), repeater(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system type to start in on next reboot."
::= { pt3080System 30 }
pt3080SystemModulationStandard OBJECT-TYPE
SYNTAX INTEGER { dvbt(0), dvbt2(1), atsc(2), isdbt(3), iboc(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Modulation Standard to start in on next reboot."
::= { pt3080System 32 }
pt3080SystemCurrentImage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flash Image the device is currently booted from."
::= { pt3080System 23 }
pt3080SystemInstrumentKU OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument serial number."
::= { pt3080System 1 }
pt3080SystemInstrumentType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product type designation."
::= { pt3080System 2 }
pt3080SystemInstrumentOptions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The options installed on this instrument."
::= { pt3080System 6 }
pt3080SystemDateTimeSync OBJECT-TYPE
SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method used to synchronize system RTC. Mode auto means use
gps if available else ntp else manual."
::= { pt3080System 20 }
pt3080SystemDateTimeSyncActual OBJECT-TYPE
SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual method used to synchronize system RTC."
::= { pt3080System 31 }
pt3080SystemTimezone OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Zone used for displaying Data and Time."
::= { pt3080System 21 }
pt3080SystemInstrumentSWRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Software Revision currently running."
::= { pt3080System 3 }
pt3080SystemInstrumentBootLoaderRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Bootloader Software Revision."
::= { pt3080System 4 }
pt3080SystemInstrumentKernelRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument O/S Kernel Version."
::= { pt3080System 5 }
pt3080SystemOperationOnTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds this unit has been turned on since production."
::= { pt3080System 34 }
pt3080SystemOperationOnAirTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds this unit has been unmuted since production."
::= { pt3080System 35 }
pt3080SystemOperationNumberOfBoots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times this unit has been booted since last factory
default restore."
::= { pt3080System 36 }
pt3080SystemBackplaneid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the backplane the device is plugged into"
::= { pt3080System 40 }
pt3080SystemBackplaneIdRaw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raw ID of the backplane the device is plugged into"
::= { pt3080System 41 }
pt3080SystemBackplaneIdPcb OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCB version of the backplane the device is plugged into"
::= { pt3080System 42 }
pt3080SystemBackplaneIdCableOptions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cable options of the backplane the device is plugged into"
::= { pt3080System 43 }
pt3080SystemBackplaneIdMAnuf OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacture ID of the backplane the device is plugged into"
::= { pt3080System 44 }
pt3080SystemBackplaneCalibrationDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration date of the backplane the device is plugged into"
::= { pt3080System 45 }
pt3080SystemBackplaneCalibrationSw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration SW version of the backplane the device is plugged
into"
::= { pt3080System 46 }
pt3080SystemBackplaneIdPartlist OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Partlist version of the backplane the device is plugged into"
::= { pt3080System 47 }
-- Scheduled Action table --
pt3080SystemScheduledActionTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080SystemScheduledActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the scheduled actions"
::= { pt3080System 50 }
pt3080SystemScheduledActionEntry OBJECT-TYPE
SYNTAX Pt3080SystemScheduledActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the scheduled action"
INDEX { pt3080SystemScheduledActionID }
::= { pt3080SystemScheduledActionTable 1 }
Pt3080SystemScheduledActionEntry ::= SEQUENCE {
pt3080SystemScheduledActionID Integer32,
pt3080SystemScheduledActionRecurrence INTEGER,
pt3080SystemScheduledActionHour Integer32,
pt3080SystemScheduledActionMinute Integer32,
pt3080SystemScheduledActionWeekday INTEGER,
pt3080SystemScheduledActionMonthDay Integer32,
pt3080SystemScheduledActionDate DisplayString,
pt3080SystemScheduledActionRandomDelay Integer32,
pt3080SystemScheduledActionAction INTEGER,
pt3080SystemScheduledActionRepeaterMode INTEGER,
pt3080SystemScheduledActionPresetNo INTEGER,
pt3080SystemScheduledActionRebootImage INTEGER,
pt3080SystemScheduledActionRebootSystemType INTEGER,
pt3080SystemScheduledActionMute INTEGER,
pt3080SystemScheduledActionSWUpgradeProtocol INTEGER,
pt3080SystemScheduledActionSWUpgradeUsername DisplayString,
pt3080SystemScheduledActionSWUpgradePassword DisplayString,
pt3080SystemScheduledActionSWUpgradeImageServer DisplayString,
pt3080SystemScheduledActionSWUpgradeImagePath DisplayString
}
pt3080SystemScheduledActionID OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 10 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this scheduled action entry"
::= { pt3080SystemScheduledActionEntry 1 }
pt3080SystemScheduledActionRecurrence OBJECT-TYPE
SYNTAX INTEGER { never(0), immediate(1), once(2), hourly(3), daily(4), weekly(5), monthly(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval at which this scheduled action entry will be executed"
::= { pt3080SystemScheduledActionEntry 2 }
pt3080SystemScheduledActionHour OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 23 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence hour used when pt3080SystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly."
::= { pt3080SystemScheduledActionEntry 3 }
pt3080SystemScheduledActionMinute OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 59 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence minute used when pt3080SystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly."
::= { pt3080SystemScheduledActionEntry 4 }
pt3080SystemScheduledActionWeekday OBJECT-TYPE
SYNTAX INTEGER { monday(0), tuesday(1), wednesday(2), thursday(3), friday(4), saturday(5), sunday(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence weekday used when pt3080SystemScheduledActionRecurrence is weekly."
::= { pt3080SystemScheduledActionEntry 5 }
pt3080SystemScheduledActionMonthDay OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 31 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence day of the monthe used when pt3080SystemScheduledActionRecurrence is monthly."
::= { pt3080SystemScheduledActionEntry 6 }
pt3080SystemScheduledActionDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence date used when pt3080SystemScheduledActionRecurrence is once.
The format is dd/mm/yyyy."
::= { pt3080SystemScheduledActionEntry 7 }
pt3080SystemScheduledActionRandomDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 600 )
UNITS "secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An extra random delay added before the action for this entry is executed.
A setting of x means that a random delay between 0 and x seconds are added."
::= { pt3080SystemScheduledActionEntry 8 }
pt3080SystemScheduledActionAction OBJECT-TYPE
SYNTAX INTEGER { none(0), repeatermode(1), preset(2), swupgrade(3), reboot(4), mute(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The action for this entry is executed"
::= { pt3080SystemScheduledActionEntry 9 }
pt3080SystemScheduledActionRepeaterMode OBJECT-TYPE
SYNTAX INTEGER { auto(0),
digital-iso-repeater(1),
digital-transposer(2),
analog-iso-repeater(3),
analog-transposer(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The new repeater mode to change to when pt3080SystemScheduledActionAction
of type repeatermode is executed"
::= { pt3080SystemScheduledActionEntry 10 }
pt3080SystemScheduledActionPresetNo OBJECT-TYPE
SYNTAX INTEGER { auto(0),
digital-iso-repeater(1),
digital-transposer(2),
analog-iso-repeater(3),
analog-transposer(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The preset to load when pt3080SystemScheduledActionAction
of type preset is executed"
::= { pt3080SystemScheduledActionEntry 11 }
pt3080SystemScheduledActionRebootImage OBJECT-TYPE
SYNTAX INTEGER { sameimage(0), otherimage(1), image0(2), image1(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image to reboot to when pt3080SystemScheduledActionAction
of type reboot is executed"
::= { pt3080SystemScheduledActionEntry 12 }
pt3080SystemScheduledActionRebootSystemType OBJECT-TYPE
SYNTAX INTEGER { modulator(0), repeater(1), same(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system type to reboot to when pt3080SystemScheduledActionAction
of type reboot is executed"
::= { pt3080SystemScheduledActionEntry 13 }
pt3080SystemScheduledActionMute OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mute mode to change into when pt3080SystemScheduledActionAction
of type mute is executed"
::= { pt3080SystemScheduledActionEntry 14 }
pt3080SystemScheduledActionSWUpgradeProtocol OBJECT-TYPE
SYNTAX INTEGER { http(0), ftp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol to use into when pt3080SystemScheduledActionAction
of type swupgrade(3) is executed"
::= { pt3080SystemScheduledActionEntry 15 }
pt3080SystemScheduledActionSWUpgradeUsername OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The username to use into when pt3080SystemScheduledActionAction
of type swupgrade(3) is executed"
::= { pt3080SystemScheduledActionEntry 16 }
pt3080SystemScheduledActionSWUpgradePassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password to use into when pt3080SystemScheduledActionAction
of type swupgrade(3) is executed"
::= { pt3080SystemScheduledActionEntry 17 }
pt3080SystemScheduledActionSWUpgradeImageServer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The server name to use into when pt3080SystemScheduledActionAction
of type swupgrade(3) is executed"
::= { pt3080SystemScheduledActionEntry 18 }
pt3080SystemScheduledActionSWUpgradeImagePath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image path name to use into when pt3080SystemScheduledActionAction
of type swupgrade(3) is executed"
::= { pt3080SystemScheduledActionEntry 19 }
--
-- pt3080 Mode sub-tree
--
pt3080ModeListenBroadcast OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control wheter to react on broadcast tx id."
::= { pt3080Mode 40 }
pt3080ModeNetwork OBJECT-TYPE
SYNTAX INTEGER { network-mode-mfn(0), network-mode-sfn(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Network mode multi-frequency-network or single-frequency-network"
::= { pt3080Mode 1 }
pt3080ModeHierarchy OBJECT-TYPE
SYNTAX INTEGER { network-hierarchy-none(0), network-hierarchy-h1(1), network-hierarchy-h2(2), network-hierarchy-h4(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hierarchy mode. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 2 }
pt3080Modeifft OBJECT-TYPE
SYNTAX INTEGER { ifft-mode-2k(0), ifft-mode-4k(1), ifft-mode-8k(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IFFT 2k, 4k or 8k mode. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 3 }
pt3080ModeCodeRateHighPrio OBJECT-TYPE
SYNTAX INTEGER {
code-rate-1-2(0),
code-rate-2-3(1),
code-rate-3-4(2),
code-rate-5-6(3),
code-rate-7-8(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"High Priority Code Rate. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 4 }
pt3080ModeCodeRateLowPrio OBJECT-TYPE
SYNTAX INTEGER {
code-rate-1-2(0),
code-rate-2-3(1),
code-rate-3-4(2),
code-rate-5-6(3),
code-rate-7-8(4)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Priority Code Rate. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 5 }
pt3080ModeConstellation OBJECT-TYPE
SYNTAX INTEGER {
qpsk(0),
qam16(1),
qam64(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If QPSK is selected and Hierarchical is <> NONE,
then Hierarchical will be forced to NONE. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 6 }
pt3080ModeGuardInterval OBJECT-TYPE
SYNTAX INTEGER {
guard-1-32(0),
guard-1-16(1),
guard-1-8(2),
guard-1-4(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Guard Interval. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 7 }
pt3080ModeCellID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Cell ID value. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 8 }
pt3080ModeEnableCellID OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables Cell ID in the TPS information. Cannot be set if pt3080ModeMipControl is on(1).
Cannot be set to off(0) if pt3080ModeEnableDVBH is on(1)"
::= { pt3080Mode 9 }
pt3080ModeDeepInterleaver OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables Deep Interleaver. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 10 }
pt3080ModeEnableDVBH OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables DVB-H mode"
::= { pt3080Mode 11 }
pt3080ModeMpeFecLowPrio OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables MPE Fec Low Priority. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 12 }
pt3080ModeMpeFecHighPrio OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables MPE Fec High Priority. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 13 }
pt3080ModeTimeSlicingLowPrio OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables timeslicing High Priority. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 14 }
pt3080ModeTimeSlicingHighPrio OBJECT-TYPE
SYNTAX INTEGER {off(0), on(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables timeslicing High Priority. Cannot be set if pt3080ModeMipControl is on(1)."
::= { pt3080Mode 15 }
pt3080ModeSfnDelayOffset OBJECT-TYPE
SYNTAX Integer32 ( -9999999 .. 9999999 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SFN delay offset"
::= { pt3080Mode 16 }
pt3080ModeTxIdent OBJECT-TYPE
SYNTAX Integer32 ( 0..65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transport stream control identifier"
::= { pt3080Mode 17 }
pt3080ModeMipControl OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables transport stream control of modulator"
::= { pt3080Mode 18 }
pt3080ModeMfnKeepNullPackets OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables MFN mode keep null packets option"
::= { pt3080Mode 19 }
pt3080ModeNetworkDelayHP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current network delay of HP TS"
::= { pt3080Mode 20 }
pt3080ModeNetworkDelayMinHP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum network delay of HP TS seen since last reset"
::= { pt3080Mode 21 }
pt3080ModeNetworkDelayMaxHP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum network delay of HP TS seen since last reset"
::= { pt3080Mode 22 }
pt3080ModeMaxNetworkDelayHP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum allowed network delay, as received from MIP"
::= { pt3080Mode 23 }
pt3080ModeNetworkDelayMarginHP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Difference between Actual Network Delay and Max. Allowed Network Delay"
::= { pt3080Mode 24 }
pt3080ModeNetworkDelayLP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current network delay of LP TS"
::= { pt3080Mode 25 }
pt3080ModeNetworkDelayMinLP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum network delay of LP TS seen since last reset"
::= { pt3080Mode 26 }
pt3080ModeNetworkDelayMaxLP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum network delay of LP TS seen since last reset"
::= { pt3080Mode 27 }
pt3080ModeMaxNetworkDelayLP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum allowed network delay, as received from MIP"
::= { pt3080Mode 28 }
pt3080ModeNetworkDelayMarginLP OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Difference between Actual Network Delay and Max. Allowed Network Delay"
::= { pt3080Mode 29 }
pt3080ModeNetworkDelayReset OBJECT-TYPE
SYNTAX INTEGER { noop(0), reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset network delay. Always reads back as noop(0)"
::= { pt3080Mode 30 }
pt3080ModeDefaultMIPOutputPower OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default MIP value for Output Power Level. Cannot be set if pt3080ModeMipControlOutputPower is on(1)"
::= { pt3080Mode 31 }
pt3080ModeDefaultMIPOutputTimeOffset OBJECT-TYPE
SYNTAX Integer32 ( -9999999 .. 9999999 )
UNITS "x100ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default MIP value for Output SFN Time Offset. Cannot be set if pt3080ModeMipControlOutputTimeOffset is on(1)"
::= { pt3080Mode 32 }
pt3080ModeDefaultMIPOutputCellID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default MIP value for Output Cell ID. Cannot be set if pt3080ModeMipControlOutputCellId is on(1)"
::= { pt3080Mode 33 }
pt3080ModeDefaultMIPOutputFreqOffset OBJECT-TYPE
SYNTAX Integer32 ( -8388608 .. 8388607 )
UNITS "Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default MIP value for Output frequency Offset. Cannot be set if pt3080ModeMipControlOutputFreqOffset is on(1)"
::= { pt3080Mode 34 }
pt3080ModeMIPMaxSFNDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "x100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MIP value for SFN maximum delay"
::= { pt3080Mode 35 }
pt3080ModeMipControlOutputPower OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables transport stream control of ModeDefaultMIPOutputPower"
::= { pt3080Mode 36 }
pt3080ModeMipControlOutputTimeOffset OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables transport stream control of ModeDefaultMIPOutputTimeOffset"
::= { pt3080Mode 37 }
pt3080ModeMipControlOutputCellId OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables transport stream control of ModeDefaultMIPOutputCellId"
::= { pt3080Mode 38 }
pt3080ModeMipControlOutputFreqOffset OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables transport stream control of ModeDefaultMIPOutputFreqOffset"
::= { pt3080Mode 39 }
pt3080ReceptionGainControl OBJECT-TYPE
SYNTAX INTEGER { auto(0), freeze(1), manual(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the gain function mode."
::= { pt3080Reception 9 }
pt3080ReceptionGainManualValue OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 700 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines manual gain value."
::= { pt3080Reception 10 }
pt3080ReceptionGainLimitEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the Reception RF Gain limit function."
::= { pt3080Reception 11 }
pt3080ReceptionGainLimit OBJECT-TYPE
SYNTAX Integer32 ( 200 .. 700 )
UNITS "0.1 db"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines gain limit value."
::= { pt3080Reception 12 }
pt3080ReceptionGainCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 db"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current total gain."
::= { pt3080Reception 13 }
pt3080ReceptionAGCMode OBJECT-TYPE
SYNTAX INTEGER { slow(0), fast(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the AGC function mode."
::= { pt3080Reception 30 }
pt3080ReceptionAGCHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 200 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the AGC function Hysteresis."
::= { pt3080Reception 31 }
pt3080ReceptionBandwidth OBJECT-TYPE
SYNTAX INTEGER { r5(0), r6(1), r7(2), r8(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls reception bandwidth"
::= { pt3080Reception 23 }
pt3080ReceptionRFFrequency OBJECT-TYPE
SYNTAX Integer32 ( 30000000 .. 954000000 )
UNITS "1 hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the reception frequency for the tuner."
::= { pt3080Reception 1 }
pt3080ReceptionRFFrequencyOffset OBJECT-TYPE
SYNTAX Integer32 ( -500000 .. 500000 )
UNITS "1 hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the offset to be added to the reception frequency for
the tuner."
::= { pt3080Reception 2 }
pt3080ReceptionRFPolarity OBJECT-TYPE
SYNTAX INTEGER { norm(0), inv(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls RF reception Polarity"
::= { pt3080Reception 24 }
pt3080ReceptionRFSquelchEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the squelch function."
::= { pt3080Reception 6 }
pt3080ReceptionRFSquelchThreshold OBJECT-TYPE
SYNTAX Integer32 ( -800 .. -70 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Squelch function threshold."
::= { pt3080Reception 7 }
pt3080ReceptionRFSquelchHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 500 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Squelch function Hysteresis."
::= { pt3080Reception 8 }
pt3080ReceptionRFTrackingFilterEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the Reception RF Tracking Filter."
::= { pt3080Reception 35 }
pt3080ReceptionRFifLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current if level from the tuner."
::= { pt3080Reception 36 }
pt3080ReceptionRFNominalInputLevel OBJECT-TYPE
SYNTAX Integer32 ( -400 .. 100 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The nominal input level on the tuner. The dynamic range of the
tuner is from 20dB below nominal level to nominal level"
::= { pt3080Reception 37 }
pt3080ReceptionRFInputLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current RF input level on the tuner."
::= { pt3080Reception 21 }
pt3080ReceptionRFInputLevelThreshold OBJECT-TYPE
SYNTAX Integer32 ( -8000 .. -700 )
UNITS "0.01 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Input level threshold."
::= { pt3080Reception 26 }
pt3080ReceptionRFInputLevelHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 500 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Input Level Hysteresis."
::= { pt3080Reception 25 }
pt3080ReceptionIFFrequency OBJECT-TYPE
SYNTAX INTEGER { if36mhz(0), if36p15mhz(1), if40mhz(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the reception frequency for the tuner."
::= { pt3080Reception 4 }
pt3080ReceptionIFPolarity OBJECT-TYPE
SYNTAX INTEGER { norm(0), inv(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls IF reception Polarity"
::= { pt3080Reception 5 }
pt3080ReceptionIFInputLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current IF input level"
::= { pt3080Reception 22 }
pt3080ReceptionIFInputPolicy OBJECT-TYPE
SYNTAX INTEGER { rf(0), if(1), rfav(2), ifav(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls RF/IF reception Policy"
::= { pt3080Reception 3 }
pt3080ReceptionIFInput OBJECT-TYPE
SYNTAX INTEGER { if(0), rf(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current RF/IF input selected"
::= { pt3080Reception 20 }
pt3080ReceptionIFRFtoIFHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for switching reception from RF to IF input."
::= { pt3080Reception 18 }
pt3080ReceptionIFIFtoRFHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for switching reception from IF to RF input."
::= { pt3080Reception 19 }
pt3080ReceptionTunerHWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW version."
::= { pt3080Reception 40 }
pt3080ReceptionTunerHWType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW type."
::= { pt3080Reception 41 }
pt3080ReceptionTunerHWID OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW ID."
::= { pt3080Reception 42 }
pt3080ReceptionTunerHWSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW Serial Number."
::= { pt3080Reception 43 }
pt3080ReceptionTunerHWCalibrationDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW Calibration Date."
::= { pt3080Reception 44 }
pt3080ReceptionTunerHWCalibrationDataVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW Calibration Data Version."
::= { pt3080Reception 45 }
pt3080ReceptionTunerHWCalibrationSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The tuner HW Calibration SW Version."
::= { pt3080Reception 46 }
--
-- pt3080 ASI sub-tree
--
pt3080ASIInput1SyncTimeout OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 250 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the maximum time accepted between received TS packages."
::= { pt3080ASI 1 }
pt3080ASIInput2SyncTimeout OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 250 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the maximum time accepted between received TS packages."
::= { pt3080ASI 51 }
pt3080ASIInput1DataErrorLimit OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 20000 )
UNITS "0.1 bits/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the alarm limit for date error rate."
::= { pt3080ASI 2 }
pt3080ASIInput2DataErrorLimit OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 20000 )
UNITS "0.1 bits/s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the alarm limit for date error rate."
::= { pt3080ASI 52 }
pt3080ASIInput1SyncStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the sync detector"
::= { pt3080ASI 3 }
pt3080ASIInput2SyncStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the sync detector"
::= { pt3080ASI 53 }
pt3080ASIInput1SyncSignal OBJECT-TYPE
SYNTAX INTEGER { undefined(0), norm(1), inv(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the sync detector signal type"
::= { pt3080ASI 4 }
pt3080ASIInput2SyncSignal OBJECT-TYPE
SYNTAX INTEGER { undefined(0), norm(1), inv(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current state of the sync detector signal type"
::= { pt3080ASI 54 }
pt3080ASIInput1SyncTSSize OBJECT-TYPE
SYNTAX INTEGER { undefined(0), ts188(1), ts204(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current TS packet size determined by the sync detector"
::= { pt3080ASI 5 }
pt3080ASIInput2SyncTSSize OBJECT-TYPE
SYNTAX INTEGER { undefined(0), ts188(1), ts204(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current TS packet size determined by the sync detector"
::= { pt3080ASI 55 }
pt3080ASIInput1LineErrors OBJECT-TYPE
SYNTAX Integer32
UNITS "1 bits"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of line errors including IDLE stuffing."
::= { pt3080ASI 6 }
pt3080ASIInput2LineErrors OBJECT-TYPE
SYNTAX Integer32
UNITS "1 bits"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of line errors including IDLE stuffing."
::= { pt3080ASI 56 }
pt3080ASIInput1LineRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current line rate"
::= { pt3080ASI 7 }
pt3080ASIInput2LineRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current line rate"
::= { pt3080ASI 57 }
pt3080ASIInput1LineErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 bits/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current line error rate"
::= { pt3080ASI 8 }
pt3080ASIInput2LineErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 bits/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current line error rate"
::= { pt3080ASI 58 }
pt3080ASIInput1DataErrors OBJECT-TYPE
SYNTAX Integer32
UNITS "1 bits"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of data errors excluding IDLE stuffing."
::= { pt3080ASI 9 }
pt3080ASIInput2DataErrors OBJECT-TYPE
SYNTAX Integer32
UNITS "1 bits"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of data errors excluding IDLE stuffing."
::= { pt3080ASI 59 }
pt3080ASIInput1DataRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Mbps/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current data rate"
::= { pt3080ASI 10 }
pt3080ASIInput2DataRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 Mbps/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current data rate"
::= { pt3080ASI 60 }
pt3080ASIInput1DataErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 bits/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current data error rate"
::= { pt3080ASI 11 }
pt3080ASIInput2DataErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 bits/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current data error rate"
::= { pt3080ASI 61 }
pt3080ASIInput1ClearErrorCounters OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear all error counters and reset all rates"
::= { pt3080ASI 12 }
pt3080ASIInput2ClearErrorCounters OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear all error counters and reset all rates"
::= { pt3080ASI 62 }
--
-- pt3080 Input sub-tree
--
pt3080InputRefDevType OBJECT-TYPE
SYNTAX INTEGER { tcxo-int(0), ocxo-pt3710-10(1), ocxo-pt3710-20(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of TCXO/OCXO"
::= { pt3080Input 90 }
pt3080InputRefCalDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration Date"
::= { pt3080Input 91 }
pt3080InputRefCalVer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration SW Version"
::= { pt3080Input 92 }
pt3080InputRefDirection OBJECT-TYPE
SYNTAX INTEGER { input(0), output(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"monitors the Reference signal direction. state: - inputOutput[inputOutput_INPUT]
- inputOutput[inputOutput_OUTPUT]"
::= { pt3080Input 1 }
pt3080InputRefSource OBJECT-TYPE
SYNTAX INTEGER { auto(0), ext(1), int(2), gps(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the input reference synchronisation source. If the value
AUTO is chosen, the source is chosen automatically between
available sources. The order of choice is GPS->EXT10MHz->INT.
If the value EXT is chosen, the external clock is chosen as
source If the value INT is chosen, the internal clock is chosen
as source. If the value GPS is chosen, the GNSS 1PPS clock
is chosen as source."
::= { pt3080Input 2 }
pt3080InputRefStatus OBJECT-TYPE
SYNTAX INTEGER { external(0), external-10mhz(1), external-1pps(2), internal(3), gnss(4), asi1(5), asi2(6), ndel(7) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"returns the current input reference synchronisation source."
::= { pt3080Input 11 }
pt3080InputRef10MhzImpedance OBJECT-TYPE
SYNTAX INTEGER { o-50(0), himp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 10 MHz input reference synchronisation
source impedance. The value is either 50O or high impedance."
::= { pt3080Input 3 }
pt3080InputRef10MhzHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 10 MHz input reference synchronisation
source impedance. The value is either 50O or high impedance."
::= { pt3080Input 7 }
pt3080InputRef10MhzHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for input reference source 10MHz failure
is forever"
::= { pt3080Input 8 }
pt3080InputRef1PPSImpedance OBJECT-TYPE
SYNTAX INTEGER { o-50(0), himp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 1 PPS input reference synchronisation source
impedance. The value is either 50ohm or high impedance."
::= { pt3080Input 4 }
pt3080InputRef1PPSHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 1 PPS input reference synchronisation source
impedance. The value is either 50ohm or high impedance."
::= { pt3080Input 9 }
pt3080InputRef1PPSHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for input reference source 1 pps failure
is forever"
::= { pt3080Input 10 }
pt3080InputRef1PPSTrigSlope OBJECT-TYPE
SYNTAX INTEGER { rising(0), falling(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the trigger edge of the external 1PPS input reference
clock. The value is either RISING or FALLING."
::= { pt3080Input 5 }
pt3080InputRef1PPSTrigLevel OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 16 )
UNITS "0.1 v"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the trigger level of the external 1PPS input reference
clock"
::= { pt3080Input 6 }
pt3080InputASIAutoRoutingDelayHp2Lp OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay before performing the actual substitution where TS-Primary
-> TS-LP and TS-Secondary -> TS-HP"
::= { pt3080Input 15 }
pt3080InputASIAutoRoutingDelayLp2Hp OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay before performing the actual substitution where TS-Primary
-> TS-HP and TS-Secondary -> TS-LP"
::= { pt3080Input 16 }
pt3080InputASIHoldoverTimeout OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 3600 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time ASI Holdover will be active, if seamless ASI switching
is not possible"
::= { pt3080Input 17 }
pt3080InputASITSPrimarySource OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
demodulator-1(2), demodulator-2(3),
tsoip-rx1(4), tsoip-rx2(5),
satRecv(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-Primary input source connector selected"
::= { pt3080Input 12 }
pt3080InputASITSSecondarySource OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
demodulator-1(2), demodulator-2(3),
tsoip-rx1(4), tsoip-rx2(5),
satRecv(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-Secondary input source connector selected"
::= { pt3080Input 13 }
pt3080InputASIAutoRoutingPolicy OBJECT-TYPE
SYNTAX INTEGER { only-use-primary(0), only-use-secondary(1),
use-primary-if-available(2), use-any-available(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The policy to use for TS auto routing"
::= { pt3080Input 14 }
pt3080InputTSPrimaryMaxPATDelay OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 10000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Max delay between the Program Association Table (PAT) on
the incomming transport stream."
::= { pt3080Input 18 }
pt3080InputTSPrimaryMaxPATDelayEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Max delay between PAT table updates
has been exceeded."
::= { pt3080Input 19 }
pt3080InputTSPrimaryExpectedTSID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-ID value expected on the incoming TS stream."
::= { pt3080Input 20 }
pt3080InputTSPrimaryExpectedTSIDEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the TS-ID is not the expected value."
::= { pt3080Input 21 }
pt3080InputTSPrimaryExpectedNWID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The NW-ID value expected on the incoming TS stream."
::= { pt3080Input 22 }
pt3080InputTSPrimaryExpectedNWIDEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the NW-ID is not the expected value."
::= { pt3080Input 23 }
pt3080InputTSPrimaryMaxStuffingrate OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The expected stuffing rate on the incoming TS stream."
::= { pt3080Input 24 }
pt3080InputTSPrimaryMaxStuffingrateEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Stuffing rate is over the expected
value."
::= { pt3080Input 25 }
pt3080InputTSPrimaryMinDelaymargin OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum delay margin of the incoming TS stream."
::= { pt3080Input 64 }
pt3080InputTSPrimaryMinDelaymarginEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Minimum Delay margin is not according
to the expected value."
::= { pt3080Input 65 }
pt3080InputTSPrimaryMaxMissingmip OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 255 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum seconds of missing mip information from the incoming
TS stream."
::= { pt3080Input 68 }
pt3080InputTSPrimaryMaxMissingmipEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Maximum missing mip is not according
to the expected value."
::= { pt3080Input 69 }
pt3080InputTSSecondaryMaxPATDelay OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 10000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Max delay between the Program Association Table (PAT) on
the incomming transport stream."
::= { pt3080Input 27 }
pt3080InputTSSecondaryMaxPATDelayEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Max delay between PAT table updates
has been exceeded."
::= { pt3080Input 28 }
pt3080InputTSSecondaryExpectedTSID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-ID value expected on the incoming TS stream."
::= { pt3080Input 29 }
pt3080InputTSSecondaryExpectedTSIDEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the TS-ID is not the expected value."
::= { pt3080Input 30 }
pt3080InputTSSecondaryExpectedNWID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The NW-ID value expected on the incoming TS stream."
::= { pt3080Input 31 }
pt3080InputTSSecondaryExpectedNWIDEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the NW-ID is not the expected value."
::= { pt3080Input 32 }
pt3080InputTSSecondaryMaxStuffingrate OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The expected stuffing rate on the incoming TS stream."
::= { pt3080Input 33 }
pt3080InputTSSecondaryMaxStuffingrateEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Stuffing rate is over the expected
value."
::= { pt3080Input 34 }
pt3080InputTSSecondaryMinDelaymargin OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum delay margin of the incoming TS stream."
::= { pt3080Input 66 }
pt3080InputTSSecondaryMinDelaymarginEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Minimum Delay margin is not according
to the expected value."
::= { pt3080Input 67 }
pt3080InputTSSecondaryMaxMissingmip OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 255 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum seconds of missing mip information from the incoming
TS stream."
::= { pt3080Input 73 }
pt3080InputTSSecondaryMaxMissingmipEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables TS switching if the Maximum missing mip is not according
to the expected value."
::= { pt3080Input 74 }
pt3080InputTSPrimaryMaxStsJitter OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 500 )
UNITS "100ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Max STS jitter on the TS-Primary"
::= { pt3080Input 26 }
pt3080InputTSSecondaryMaxStsJitter OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 500 )
UNITS "100ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Max STS jitter on the TS-Secondary"
::= { pt3080Input 35 }
pt3080InputTSPrimaryStatus OBJECT-TYPE
SYNTAX INTEGER { available(0), unavailable(1), nosync(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state for TS-Primary. Unavailable means violation of alarms."
::= { pt3080Input 36 }
pt3080InputTSSecondaryStatus OBJECT-TYPE
SYNTAX INTEGER { available(0), unavailable(1), nosync(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state for TS-Secondary. Unavailable means violation of alarms."
::= { pt3080Input 37 }
pt3080InputTSHp OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
demodulator-1(2), demodulator-2(3),
tsoip-rx1(4), tsoip-rx2(5),
satRecv(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input source currently On Air. (TS-HP)"
::= { pt3080Input 38 }
pt3080InputTSLp OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
demodulator-1(2), demodulator-2(3),
tsoip-rx1(4), tsoip-rx2(5),
satRecv(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input source currently used as backup. (TS-LP)"
::= { pt3080Input 39 }
pt3080InputEffectiveAutoroutingPolicy OBJECT-TYPE
SYNTAX INTEGER { only-primary(0), only-secondary(1), prefer-primary(2), any-available(3), seamless(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects the effective ASI Autorouting Policy"
::= { pt3080Input 40 }
pt3080InputTSHpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current bitrate for On Air TS. (TS-HP)"
::= { pt3080Input 41 }
pt3080InputTSHpPacketsBuffered OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current number of packets buffered for On Air TS (TS-HP)"
::= { pt3080Input 42 }
pt3080InputTSHpPacketSize OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current size of packets for On Air TS (TS-HP)"
::= { pt3080Input 43 }
pt3080InputTSHpStuffingrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current NULL stuffing as a percentage of the
current bitrate for On Air TS (TS-HP)"
::= { pt3080Input 44 }
pt3080InputTSHpTSID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Transport Stream ID for On Air TS. (TS-HP)"
::= { pt3080Input 45 }
pt3080InputTSHpNWID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Network ID for On Air TS. (TS-HP)"
::= { pt3080Input 46 }
pt3080InputTSLpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current bitrate for Backup TS. (TS-LP)"
::= { pt3080Input 47 }
pt3080InputTSLpPacketsBuffered OBJECT-TYPE
SYNTAX Integer32
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current number of packets buffered for Backup TS. (TS-LP)"
::= { pt3080Input 48 }
pt3080InputTSLpPacketSize OBJECT-TYPE
SYNTAX Integer32
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current size of packets for Backup TS. (TS-LP)"
::= { pt3080Input 49 }
pt3080InputTSLpStuffingrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Permille"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current NULL stuffing as a percentage of the
current bitrate for Backup TS. (TS-LP)"
::= { pt3080Input 50 }
pt3080InputTSLpTSID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Transport Stream ID for Backup TS. (TS-LP)"
::= { pt3080Input 51 }
pt3080InputTSLpNWID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Network ID for Backup TS. (TS-LP)"
::= { pt3080Input 52 }
pt3080InputTSPrimaryStsJitter OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current STS jitter on the TS-Primary."
::= { pt3080Input 53 }
pt3080InputTSPrimaryStsJitterMax OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum STS jitter value seen on the TS-Primary"
::= { pt3080Input 54 }
pt3080InputTSPrimaryStsJitterMin OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum STS jitter value seen on the TS-Primary"
::= { pt3080Input 55 }
pt3080InputTSPrimaryStsJitterReset OBJECT-TYPE
SYNTAX INTEGER { noop(0), reset-min-max(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the pt3080InputTSPrimaryStsJitterMax and pt3080InputTSPrimaryStsJitterMin values"
::= { pt3080Input 56 }
pt3080InputTSSecondaryStsJitter OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current STS jitter on the TS-Secondary"
::= { pt3080Input 57 }
pt3080InputTSSecondaryStsJitterMax OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum STS jitter value seen on the TS-Secondary"
::= { pt3080Input 58 }
pt3080InputTSSecondaryStsJitterMin OBJECT-TYPE
SYNTAX Integer32
UNITS "100ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum STS jitter value seen on the TS-Secondary"
::= { pt3080Input 59 }
pt3080InputTSSecondaryStsJitterReset OBJECT-TYPE
SYNTAX INTEGER { noop(0), reset-min-max(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the pt3080InputTSSecondaryStsJitterMax and
pt3080InputTSSecondaryStsJitterMin values"
::= { pt3080Input 60 }
--
-- pt3080 Output sub-tree
--
pt3080OutputBandwidth OBJECT-TYPE
SYNTAX Integer32 ( 5 .. 8 )
UNITS "MHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output Bandwidth"
::= { pt3080Output 4 }
pt3080OutputChannel OBJECT-TYPE
SYNTAX Integer32 ( 21 .. 69 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Channel settings"
::= { pt3080Output 5 }
pt3080OutputSynchronized OBJECT-TYPE
SYNTAX INTEGER { not-synchronized(0), synchronized(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The values of pt3080OutputRfFrequency, pt3080OutputBandwidth and
pt3080OutputChannel are synchronized aaccording to
freq = (bw * channel) + 306000000."
::= { pt3080Output 6 }
pt3080OutputMute OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output mute. When set the mute reason UserRequest is ORed into the mute reason set.
When read it is the logical OR of all mute reasons"
::= { pt3080Output 7 }
pt3080OutputPowerLevel OBJECT-TYPE
SYNTAX Integer32 ( 280 .. 490 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired output power level."
::= { pt3080Output 9 }
pt3080OutputIfEnable OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control IF output"
::= { pt3080Output 13 }
pt3080OutputIfFrequency OBJECT-TYPE
SYNTAX Integer32 ( 35150000 .. 37150000 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output Frequency for I/F"
::= { pt3080Output 14 }
pt3080OutputIfPolarity OBJECT-TYPE
SYNTAX INTEGER { norm(0), inv(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control IF output polarity"
::= { pt3080Output 15 }
pt3080OutputIfLevel OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 0 )
UNITS "0.01 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output Level for I/F"
::= { pt3080Output 16 }
pt3080OutputMode OBJECT-TYPE
SYNTAX INTEGER { normal(0), standby(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control RF output mode"
::= { pt3080Output 1 }
pt3080OutputEffectiveLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective RF Output Level"
::= { pt3080Output 17 }
pt3080OutputActualLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual RF Output Level"
::= { pt3080Output 18 }
pt3080OutputPolarity OBJECT-TYPE
SYNTAX INTEGER { norm(0), inv(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control RF output polarity"
::= { pt3080Output 8 }
pt3080OutputRfFrequency OBJECT-TYPE
SYNTAX Integer32 ( 30000000 .. 860000000 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output RF frequency"
::= { pt3080Output 2 }
pt3080OutputRfFrequencyOffset OBJECT-TYPE
SYNTAX Integer32 ( -8388608 .. 8388607 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output RF frequency offset"
::= { pt3080Output 10 }
pt3080OutputRfLevel OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.01 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the output level in 0.01dB steps, 0dB is +6dBm on IF, 0dBm
on RF"
::= { pt3080Output 3 }
pt3080OutputRfCableMode OBJECT-TYPE
SYNTAX INTEGER { none(0), const(1), auto(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control whether Cable Level loss compensation should be enabled"
::= { pt3080Output 50 }
pt3080OutputRfCableConstantLevelOffset OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Constant level offset to add to RF Output level. Only used if
mode is Constant."
::= { pt3080Output 51 }
pt3080OutputRfCableFrequencyLevelOffset0 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 52 }
pt3080OutputRfCableFrequencyLevelOffset1 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 53 }
pt3080OutputRfCableFrequencyLevelOffset2 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 54 }
pt3080OutputRfCableFrequencyLevelOffset3 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 55 }
pt3080OutputRfCableFrequencyLevelOffset4 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 56 }
pt3080OutputRfCableFrequencyLevelOffset5 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { pt3080Output 57 }
pt3080OutputRfDetectedActualLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected Output Level for RF"
::= { pt3080Output 19 }
pt3080OutputRfDetectedLowerLevelLimit OBJECT-TYPE
SYNTAX Integer32 ( 2 .. 50 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Limit to how much lower the detected RF output level can be
than the configured level."
::= { pt3080Output 20 }
pt3080OutputRfDetectedLowerLevelcontrol OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the lower limit for RF output level is enforced."
::= { pt3080Output 21 }
pt3080OutputRfDetectedHigherLevelLimit OBJECT-TYPE
SYNTAX Integer32 ( 2 .. 50 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Limit to how much higher the detected RF output level can be
than the configured level."
::= { pt3080Output 22 }
pt3080OutputRfDetectedHigherLevelcontrol OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the higher limit for RF output level is enforced."
::= { pt3080Output 23 }
pt3080OutputRfAlcControl OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the ALC system is enabled or disabled."
::= { pt3080Output 30 }
pt3080OutputRfAlcSense OBJECT-TYPE
SYNTAX INTEGER { rfsense1(0), rfsense2(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which sense port is used by the ALC system if the ALC
is enabled."
::= { pt3080Output 31 }
pt3080OutputRfAlcSetpointPort1 OBJECT-TYPE
SYNTAX Integer32 ( -11000 .. 11000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ALC setpoint for RF Sense Port 1"
::= { pt3080Output 32 }
pt3080OutputRfAlcSetpointPort2 OBJECT-TYPE
SYNTAX Integer32 ( -11000 .. 11000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ALC setpoint for RF Sense Port 2"
::= { pt3080Output 33 }
pt3080OutputRfAlcStatus OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status for whether the ALC system is enabled or disabled."
::= { pt3080Output 34 }
pt3080OutputRfAlcStatusInformation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the state of the ALC system."
::= { pt3080Output 35 }
--
-- pt3080 GPS sub-tree
--
pt3080GpsBias OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the bias to be either on or off for the GPS antenna
DC supply (5V or 3V DC). An active GPS antenna requires a power
supply i.e. requires this parameter to set to ON."
::= { pt3080Gps 4 }
pt3080GpsbiasVoltage OBJECT-TYPE
SYNTAX INTEGER { gpsant-5v(0), gpsant-33v(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the gps antenna bias voltage. An active GPS antenna
requires a power supply of either 3V or 5V."
::= { pt3080Gps 15 }
pt3080GpsCableDelay OBJECT-TYPE
SYNTAX Integer32 ( -18125 .. 13750 )
UNITS "0.1 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the antenna cable compensation delay. If the GPS antenna
is situated far away from the receiver itself the signal will
be delayed and must be compensated."
::= { pt3080Gps 12 }
pt3080GpsHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether the GPS system is allowed to operate infinitely
(YES) following loss of GPS locking using the internal GPS
chip oscillator or not (NO).In case NO is chosen the GPS holdover
time applies."
::= { pt3080Gps 11 }
pt3080GpsHoldoverTime OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the GPS holdover time. This value is ignored if the
holdover forever (see below) is set to YES If the GPS locking
is lost the system is allowed to continue operating for holdover
time seconds using the internal GPS chip oscillator. If - when
the holdover time interval expires - the GPS locking it still
lost, the GPS operation will be maintained using external timing
if present. If external timing is not present the GPS operation
will be maintained using the internal motherboard oscillator."
::= { pt3080Gps 10 }
pt3080GpsSatelliteSystemGPS OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GPS satellites are used to obtain position
and timing information."
::= { pt3080Gps 16 }
pt3080GpsSatelliteSystemGLONASS OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GLONASS satellites are used to obtain position
and timing information."
::= { pt3080Gps 17 }
pt3080GpsSatelliteSystemGALILEO OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GALILEO satellites are used to obtain position
and timing information."
::= { pt3080Gps 18 }
pt3080GpsSatelliteSystemCOMPASS OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether COMPASS satellites are used to obtain position
and timing information."
::= { pt3080Gps 19 }
pt3080GpsVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the GPS chip firmware version as a string."
::= { pt3080Gps 9 }
pt3080Gps1PPSStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current locking state of the GPS system. The value
LOCKED indicates that the GPS system is locked to a sufficient
number of satellites to perform well. UNLOCKED indicates that
it is not. For the GPS system to perform well at least 4 satellites
must be visible with a proper signal to noise ratio."
::= { pt3080Gps 1 }
pt3080GpsState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns a string describing the GPS state. For informational
purposes."
::= { pt3080Gps 13 }
pt3080GpsVisibleSatellitesSnr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the average signal to noise ratio of all visible satellites
via the built-in GPS receiver"
::= { pt3080Gps 14 }
pt3080GpsVisibleSatellites OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the number of currently visible satellites via the built-in
GPS receiver. A satellite is visible if at all detectable by
the GPS system i.e. regardless of signal to noise ratio. Note
that the upper value N can change with the launch of new satellites.
For some time, however, the GPS system has had a total of 24
satellites."
::= { pt3080Gps 2 }
pt3080GpsTrackedSatellites OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the number of currently tracked satellites via the GPS
receiver."
::= { pt3080Gps 3 }
pt3080GpsLongtitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current longtitude derived from
the received GPS signal(s). The string format is DDD MM SS C.
according to the following: - DD denotes degrees in the intervals
[0 .. 180]. MM and SS denote minutes/seconds in the interval
[0 .. 59]. C denotes E, W (East, West)."
::= { pt3080Gps 6 }
pt3080GpsLatitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current latitude derived from the
received GPS signal(s). The string format is DD MM SS C. according
to the following: - DD denotes degrees in the intervals [0
.. 90]. MM and SS denote minutes/seconds in the interval [0
.. 59]. C denotes N, S (North, South)."
::= { pt3080Gps 7 }
pt3080GpsAltitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current altitude derived from the
received GPS signal(s). The string format is HHHH.c;. according
to the following: HHHH.c denotes the altitude in metres with
one digit after the comma. The altitude can be negative."
::= { pt3080Gps 8 }
--
-- pt3080 ChannelFilters sub-tree
--
--
-- Pt3080 TSoIP sub-tree
--
pt3080TSoIPRx1ReceiverEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the reception of IP/UDP packets with transport stream
data to be forward into the modulator."
::= { pt3080TSoIP 15 }
pt3080TSoIPRx2ReceiverEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the reception of IP/UDP packets with transport stream
data to be forward into the modulator."
::= { pt3080TSoIP 45 }
pt3080TSoIPRx1LanSelect OBJECT-TYPE
SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which virtual LAN interface to receive IP/UDP packets
from."
::= { pt3080TSoIP 11 }
pt3080TSoIPRx2LanSelect OBJECT-TYPE
SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which virtual LAN interface to receive IP/UDP packets
from."
::= { pt3080TSoIP 41 }
pt3080TSoIPRx1Multicast OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the reception of Multicast IP/UDP packets with transport
stream data to be forward into the modulator. If disabled,
only unicast IP/UDP packets are considdered."
::= { pt3080TSoIP 12 }
pt3080TSoIPRx2Multicast OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the reception of Multicast IP/UDP packets with transport
stream data to be forward into the modulator. If disabled,
only unicast IP/UDP packets are considdered."
::= { pt3080TSoIP 42 }
pt3080TSoIPRx1Protocol OBJECT-TYPE
SYNTAX INTEGER { udp(0), rtp(1), auto(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects which protocol to expect incoming packets to have."
::= { pt3080TSoIP 13 }
pt3080TSoIPRx2Protocol OBJECT-TYPE
SYNTAX INTEGER { udp(0), rtp(1), auto(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects which protocol to expect incoming packets to have."
::= { pt3080TSoIP 43 }
pt3080TSoIPRx1Portnumber OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which UDP port number to receive IP/UDP packets from."
::= { pt3080TSoIP 14 }
pt3080TSoIPRx2Portnumber OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which UDP port number to receive IP/UDP packets from."
::= { pt3080TSoIP 44 }
pt3080TSoIPRx1PacketErrorRatioLimit OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 500 )
UNITS "0.1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies limit for the Packet Error Ratio. If the limit is
exceeded and alarm is raised."
::= { pt3080TSoIP 16 }
pt3080TSoIPRx2PacketErrorRatioLimit OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 500 )
UNITS "0.1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies limit for the Packet Error Ratio. If the limit is
exceeded and alarm is raised."
::= { pt3080TSoIP 46 }
pt3080TSoIPRx1MinumimLatency OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 5000 )
UNITS "0.1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the minimum time incoming data is buffered. The value
configured might be modified by FEC row/column sized on the
incoming data."
::= { pt3080TSoIP 10 }
pt3080TSoIPRx2MinumimLatency OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 5000 )
UNITS "0.1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the minimum time incoming data is buffered. The value
configured might be modified by FEC row/column sized on the
incoming data."
::= { pt3080TSoIP 40 }
pt3080TSoIPRx1SyncTimeout OBJECT-TYPE
SYNTAX Integer32 ( 16 .. 250 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the maximum time accepted between received TS packages."
::= { pt3080TSoIP 9 }
pt3080TSoIPRx2SyncTimeout OBJECT-TYPE
SYNTAX Integer32 ( 16 .. 250 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the maximum time accepted between received TS packages."
::= { pt3080TSoIP 39 }
pt3080TSoIPRx1Status OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1), disabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the receiver. Locked means minimum of
3 IP/UDP frames received per second."
::= { pt3080TSoIP 17 }
pt3080TSoIPRx2Status OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1), disabled(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the receiver. Locked means minimum of
3 IP/UDP frames received per second."
::= { pt3080TSoIP 47 }
pt3080TSoIPRx1CurrentIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current receive IP address for the TSoIP interface."
::= { pt3080TSoIP 18 }
pt3080TSoIPRx2CurrentIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current receive IP address for the TSoIP interface."
::= { pt3080TSoIP 48 }
pt3080TSoIPRx1IpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current bitrate of uncoming traffic for this UDP port."
::= { pt3080TSoIP 26 }
pt3080TSoIPRx2IpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current bitrate of uncoming traffic for this UDP port."
::= { pt3080TSoIP 56 }
pt3080TSoIPRx1PacketErrorRatio OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 %"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current error ratio of uncoming traffic for this UDP
port."
::= { pt3080TSoIP 20 }
pt3080TSoIPRx2PacketErrorRatio OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 %"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shows the current error ratio of uncoming traffic for this UDP
port."
::= { pt3080TSoIP 50 }
pt3080TSoIPRx1SequenceErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of sequence errors on this channel on the TSoIP interface."
::= { pt3080TSoIP 19 }
pt3080TSoIPRx2SequenceErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of sequence errors on this channel on the TSoIP interface."
::= { pt3080TSoIP 49 }
pt3080TSoIPRx1LostIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of lost IP frames on the channel on the TSoIP interface.
The sequence numbers of frames employed by the RTP protocol
are used to determine this statistic."
::= { pt3080TSoIP 21 }
pt3080TSoIPRx2LostIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of lost IP frames on the channel on the TSoIP interface.
The sequence numbers of frames employed by the RTP protocol
are used to determine this statistic."
::= { pt3080TSoIP 51 }
pt3080TSoIPRx1CorrectedIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of corrected IP frames (via FEC) on this cannel on
the TSoIP interface."
::= { pt3080TSoIP 22 }
pt3080TSoIPRx2CorrectedIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of corrected IP frames (via FEC) on this cannel on
the TSoIP interface."
::= { pt3080TSoIP 52 }
pt3080TSoIPRx1OverrunIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IP frames lost on the channel on the TSoIP interface
due to overrun. Overrun happens when the outgoing rate of the
modulator is lower that the incoming rate of TSoIP data."
::= { pt3080TSoIP 30 }
pt3080TSoIPRx2OverrunIPFrames OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IP frames lost on the channel on the TSoIP interface
due to overrun. Overrun happens when the outgoing rate of the
modulator is lower that the incoming rate of TSoIP data."
::= { pt3080TSoIP 60 }
pt3080TSoIPRx1PacketsPerFrame OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent number of TS packets per IP frames on this cannel
on the TSoIP interface."
::= { pt3080TSoIP 25 }
pt3080TSoIPRx2PacketsPerFrame OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent number of TS packets per IP frames on this cannel
on the TSoIP interface."
::= { pt3080TSoIP 55 }
pt3080TSoIPRx1TSPacketSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent size of TS packets on this cannel on the TSoIP interface.
Usually 188 or 204."
::= { pt3080TSoIP 29 }
pt3080TSoIPRx2TSPacketSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent size of TS packets on this cannel on the TSoIP interface.
Usually 188 or 204."
::= { pt3080TSoIP 59 }
pt3080TSoIPRx1FecColumn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent FEC Column (L) number for this cannel on the TSoIP
interface."
::= { pt3080TSoIP 23 }
pt3080TSoIPRx2FecColumn OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent FEC Column (L) number for this cannel on the TSoIP
interface."
::= { pt3080TSoIP 53 }
pt3080TSoIPRx1FecRow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent FEC Row (D) number for this cannel on the TSoIP interface."
::= { pt3080TSoIP 24 }
pt3080TSoIPRx2FecRow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent FEC Row (D) number for this cannel on the TSoIP interface."
::= { pt3080TSoIP 54 }
pt3080TSoIPRx1QueueSize OBJECT-TYPE
SYNTAX Integer32
UNITS "1 Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent queue size for this cannel on the TSoIP interface."
::= { pt3080TSoIP 27 }
pt3080TSoIPRx2QueueSize OBJECT-TYPE
SYNTAX Integer32
UNITS "1 Frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The curent queue size for this cannel on the TSoIP interface."
::= { pt3080TSoIP 57 }
pt3080TSoIPRx1CurrentLatency OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current latency incurrent by queue size on this channel
on the TSoIP interface."
::= { pt3080TSoIP 28 }
pt3080TSoIPRx2CurrentLatency OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current latency incurrent by queue size on this channel
on the TSoIP interface."
::= { pt3080TSoIP 58 }
--
-- pt3080 Monitor sub-tree
--
pt3080MonitorSource OBJECT-TYPE
SYNTAX INTEGER { asi-in1(0), asi-in2(1), aux1(2), aux2(3), tsoiprx1(4), tsoiprx2(5), ts-hp(6), ts-lp(7), backplane1(8), backplane2(9) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the source to be monitored on the ASI monitor output."
::= { pt3080Monitor 1 }
pt3080MonitorTSoIPEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the generation of monitor data over TSoIP."
::= { pt3080Monitor 10 }
pt3080MonitorTSoIPSource OBJECT-TYPE
SYNTAX INTEGER { asi-in1(0), asi-in2(1), aux1(2), aux2(3), tsoiprx1(4), tsoiprx2(5), ts-hp(6), ts-lp(7), backplane1(8), backplane2(9) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the source to be monitored on the TSoIP monitor output."
::= { pt3080Monitor 11 }
pt3080MonitorTSoIPMulticastLanSelect OBJECT-TYPE
SYNTAX INTEGER { flan(0), alan(1), tlan(2), blan(3), plan(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies which virtual LAN interface to transmit Multicast
IP/UDP packets out via."
::= { pt3080Monitor 25 }
pt3080MonitorTSoIPDestIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the destination IP address of the data to be monitored
on the TSoIP monitor output."
::= { pt3080Monitor 12 }
pt3080MonitorTSoIPDestPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the destination UDP Port number of the data to be monitored
on the TSoIP monitor output."
::= { pt3080Monitor 13 }
pt3080MonitorTSoIPProtocol OBJECT-TYPE
SYNTAX INTEGER { udp(0), rtp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the protocol to be used on the TSoIP monitor output."
::= { pt3080Monitor 14 }
pt3080MonitorTSoIPEnableFec OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable FEC protocol on the output data from the TSoIP
Monitor."
::= { pt3080Monitor 15 }
pt3080MonitorTSoIPFecColumn OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 20 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the FEC protocoll Column number (L) of the data to be
monitored on the TSoIP monitor output."
::= { pt3080Monitor 16 }
pt3080MonitorTSoIPFecRow OBJECT-TYPE
SYNTAX Integer32 ( 4 .. 20 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the FEC protocol Row number (D) of the data to be monitored
on the TSoIP monitor output."
::= { pt3080Monitor 17 }
pt3080MonitorTSoIPFecSkew OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 4 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the FEC protocol Skew (non block alignment of FEC Frame)
of the data to be monitored on the TSoIP monitor output."
::= { pt3080Monitor 18 }
pt3080MonitorTSoIPKeepNullPackets OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Retain or discard Null packets of the generation of monitor
data over TSoIP."
::= { pt3080Monitor 19 }
pt3080MonitorTSoIPPacketsPerFrame OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 7 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the number of TS packets to send per IP frame on the TSoIP
monitor output."
::= { pt3080Monitor 20 }
pt3080MonitorTSoIPUDPChecksum OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Generate UDP checksum in the outgoing packets of the TSoIP Monitor."
::= { pt3080Monitor 21 }
pt3080MonitorTSoIPDSCP OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the value of the TOS/DSCP field in IP packets to be
sent on the TSoIP monitor output."
::= { pt3080Monitor 22 }
pt3080MonitorTSoIPTTL OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 255 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the value of the TTL (Time-To-Live) field in IP packets
to be sent on the TSoIP monitor output."
::= { pt3080Monitor 23 }
pt3080MonitorTSoIPGenerateError OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Artificially generate an error rate as a percentage of frames
lost on the TSoIP monitor output."
::= { pt3080Monitor 24 }
pt3080MonitorTSoIPIpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current rate IP packets traffic to be sent on the TSoIP
monitor output."
::= { pt3080Monitor 30 }
pt3080MonitorTSoIPTSSize OBJECT-TYPE
SYNTAX Integer32
UNITS "1 bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current TS packet size (188 or 204) on the TSoIP monitor
output."
::= { pt3080Monitor 32 }
pt3080MonitorTSoIPLostIPFrames OBJECT-TYPE
SYNTAX Integer32
UNITS "1 Mbps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of IP packets traffic generated but lost on the TSoIP
monitor output."
::= { pt3080Monitor 31 }
--
-- pt3080 Test sub-tree
--
pt3080TestEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), scar(1), sweep2(2), prbs-on(3), prbs-auto(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"controls the test signal generation. This cannot be used when
network mode is SFN. Only a subset is available in repeater
mode. test signal output state: - testSignalsArray[testSignals_OFF]
Normal operation. No test signal. - testSignalsArray[testSignals_SCAR]
A single carrier output is provided. - testSignalsArray[testSignals_SWEEP2]
A test signal with full spectrum bandwidth and a 3dB peak to
average power ratio. (OFDM PPR-3). - testSignalsArray[testSignals_PRBSON]
Forced transmission of stuffing data only (null packets) irrespective
of the status of the MPEG-2 transport stream input. - testSignalsArray[testSignals_PRBSAUTO]
Automatic transmission of spectrum based on stuffing data when
no MPEG-2 TS input is available."
::= { pt3080Test 1 }
pt3080TestEnableReconnect OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the test signal shall reconnect after reset.
This value is saved in non-volatile memory and thus survives
a reboot. - onOffArray[TEXT_INDEX_OFF] The selected test signal
will be set to OFF after reset. - onOffArray[TEXT_INDEX_ON]
The selected test signal will be output after reset."
::= { pt3080Test 2 }
pt3080TestScarrierLevel OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control level of the single carrier test signal."
::= { pt3080Test 3 }
pt3080TestscarrierFrequencyOffset OBJECT-TYPE
SYNTAX Integer32 ( -4000000 .. 4000000 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control frequency offset of the single carrier test signal."
::= { pt3080Test 4 }
--
-- pt3080 Alarm sub-tree
--
-- Group Alarm table --
pt3080GroupAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080GroupAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the group alarms"
::= { pt3080Alarm 1 }
pt3080GroupAlarmEntry OBJECT-TYPE
SYNTAX Pt3080GroupAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080GroupAlarmID }
::= { pt3080GroupAlarmTable 1 }
Pt3080GroupAlarmEntry ::= SEQUENCE {
pt3080GroupAlarmID Integer32,
pt3080GroupAlarmDescription DisplayString,
pt3080GroupAlarmState INTEGER,
pt3080GroupAlarmActionEventlog INTEGER,
pt3080GroupAlarmActionRelay1 INTEGER,
pt3080GroupAlarmActionRelay2 INTEGER,
pt3080GroupAlarmActionTrap INTEGER,
pt3080GroupAlarmActionEmail INTEGER,
pt3080GroupAlarmActionAlarmLED INTEGER,
pt3080GroupAlarmActionForceMode INTEGER
}
pt3080GroupAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080GroupAlarmEntry 1 }
pt3080GroupAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080GroupAlarmEntry 2 }
pt3080GroupAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current GroupAlarm state condition"
::= { pt3080GroupAlarmEntry 3 }
pt3080GroupAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080GroupAlarmEntry 4 }
pt3080GroupAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080GroupAlarmEntry 5 }
pt3080GroupAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080GroupAlarmEntry 6 }
pt3080GroupAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080GroupAlarmEntry 7 }
pt3080GroupAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080GroupAlarmEntry 8 }
pt3080GroupAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080GroupAlarmEntry 9 }
pt3080GroupAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080GroupAlarmEntry 10 }
-- ASI TS-Primary Alarm table --
pt3080ASITSPrimaryAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080ASITSPrimaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the ASI TS-Primary alarms"
::= { pt3080Alarm 5 }
pt3080ASITSPrimaryAlarmEntry OBJECT-TYPE
SYNTAX Pt3080ASITSPrimaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080ASITSPrimaryAlarmID }
::= { pt3080ASITSPrimaryAlarmTable 1 }
Pt3080ASITSPrimaryAlarmEntry ::= SEQUENCE {
pt3080ASITSPrimaryAlarmID Integer32,
pt3080ASITSPrimaryAlarmDescription DisplayString,
pt3080ASITSPrimaryAlarmState INTEGER,
pt3080ASITSPrimaryAlarmActionEventlog INTEGER,
pt3080ASITSPrimaryAlarmActionRelay1 INTEGER,
pt3080ASITSPrimaryAlarmActionRelay2 INTEGER,
pt3080ASITSPrimaryAlarmActionTrap INTEGER,
pt3080ASITSPrimaryAlarmActionEmail INTEGER,
pt3080ASITSPrimaryAlarmActionAlarmLED INTEGER,
pt3080ASITSPrimaryAlarmActionForceMode INTEGER
}
pt3080ASITSPrimaryAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080ASITSPrimaryAlarmEntry 1 }
pt3080ASITSPrimaryAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080ASITSPrimaryAlarmEntry 2 }
pt3080ASITSPrimaryAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ASITSPrimaryAlarm state condition"
::= { pt3080ASITSPrimaryAlarmEntry 3 }
pt3080ASITSPrimaryAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080ASITSPrimaryAlarmEntry 4 }
pt3080ASITSPrimaryAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080ASITSPrimaryAlarmEntry 5 }
pt3080ASITSPrimaryAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080ASITSPrimaryAlarmEntry 6 }
pt3080ASITSPrimaryAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080ASITSPrimaryAlarmEntry 7 }
pt3080ASITSPrimaryAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080ASITSPrimaryAlarmEntry 8 }
pt3080ASITSPrimaryAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080ASITSPrimaryAlarmEntry 9 }
pt3080ASITSPrimaryAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080ASITSPrimaryAlarmEntry 10 }
-- ASI TS-Secondary Alarm table --
pt3080ASITSSecondaryAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080ASITSSecondaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the ASI alarms"
::= { pt3080Alarm 6 }
pt3080ASITSSecondaryAlarmEntry OBJECT-TYPE
SYNTAX Pt3080ASITSSecondaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080ASITSSecondaryAlarmID }
::= { pt3080ASITSSecondaryAlarmTable 1 }
Pt3080ASITSSecondaryAlarmEntry ::= SEQUENCE {
pt3080ASITSSecondaryAlarmID Integer32,
pt3080ASITSSecondaryAlarmDescription DisplayString,
pt3080ASITSSecondaryAlarmState INTEGER,
pt3080ASITSSecondaryAlarmActionEventlog INTEGER,
pt3080ASITSSecondaryAlarmActionRelay1 INTEGER,
pt3080ASITSSecondaryAlarmActionRelay2 INTEGER,
pt3080ASITSSecondaryAlarmActionTrap INTEGER,
pt3080ASITSSecondaryAlarmActionEmail INTEGER,
pt3080ASITSSecondaryAlarmActionAlarmLED INTEGER,
pt3080ASITSSecondaryAlarmActionForceMode INTEGER
}
pt3080ASITSSecondaryAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080ASITSSecondaryAlarmEntry 1 }
pt3080ASITSSecondaryAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080ASITSSecondaryAlarmEntry 2 }
pt3080ASITSSecondaryAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ASITSSecondaryAlarm state condition"
::= { pt3080ASITSSecondaryAlarmEntry 3 }
pt3080ASITSSecondaryAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080ASITSSecondaryAlarmEntry 4 }
pt3080ASITSSecondaryAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080ASITSSecondaryAlarmEntry 5 }
pt3080ASITSSecondaryAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080ASITSSecondaryAlarmEntry 6 }
pt3080ASITSSecondaryAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080ASITSSecondaryAlarmEntry 7 }
pt3080ASITSSecondaryAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080ASITSSecondaryAlarmEntry 8 }
pt3080ASITSSecondaryAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080ASITSSecondaryAlarmEntry 9 }
pt3080ASITSSecondaryAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080ASITSSecondaryAlarmEntry 10 }
-- SFN Alarm table --
pt3080SFNAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080SFNAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the SFN alarms"
::= { pt3080Alarm 7 }
pt3080SFNAlarmEntry OBJECT-TYPE
SYNTAX Pt3080SFNAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080SFNAlarmID }
::= { pt3080SFNAlarmTable 1 }
Pt3080SFNAlarmEntry ::= SEQUENCE {
pt3080SFNAlarmID Integer32,
pt3080SFNAlarmDescription DisplayString,
pt3080SFNAlarmState INTEGER,
pt3080SFNAlarmActionEventlog INTEGER,
pt3080SFNAlarmActionRelay1 INTEGER,
pt3080SFNAlarmActionRelay2 INTEGER,
pt3080SFNAlarmActionTrap INTEGER,
pt3080SFNAlarmActionEmail INTEGER,
pt3080SFNAlarmActionAlarmLED INTEGER,
pt3080SFNAlarmActionForceMode INTEGER
}
pt3080SFNAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080SFNAlarmEntry 1 }
pt3080SFNAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080SFNAlarmEntry 2 }
pt3080SFNAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current SFNAlarm state condition"
::= { pt3080SFNAlarmEntry 3 }
pt3080SFNAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080SFNAlarmEntry 4 }
pt3080SFNAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080SFNAlarmEntry 5 }
pt3080SFNAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080SFNAlarmEntry 6 }
pt3080SFNAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080SFNAlarmEntry 7 }
pt3080SFNAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080SFNAlarmEntry 8 }
pt3080SFNAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080SFNAlarmEntry 9 }
pt3080SFNAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080SFNAlarmEntry 10 }
-- Reference Alarm table --
pt3080ReferenceAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080ReferenceAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Reference alarms"
::= { pt3080Alarm 8 }
pt3080ReferenceAlarmEntry OBJECT-TYPE
SYNTAX Pt3080ReferenceAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080ReferenceAlarmID }
::= { pt3080ReferenceAlarmTable 1 }
Pt3080ReferenceAlarmEntry ::= SEQUENCE {
pt3080ReferenceAlarmID Integer32,
pt3080ReferenceAlarmDescription DisplayString,
pt3080ReferenceAlarmState INTEGER,
pt3080ReferenceAlarmActionEventlog INTEGER,
pt3080ReferenceAlarmActionRelay1 INTEGER,
pt3080ReferenceAlarmActionRelay2 INTEGER,
pt3080ReferenceAlarmActionTrap INTEGER,
pt3080ReferenceAlarmActionEmail INTEGER,
pt3080ReferenceAlarmActionAlarmLED INTEGER,
pt3080ReferenceAlarmActionForceMode INTEGER
}
pt3080ReferenceAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080ReferenceAlarmEntry 1 }
pt3080ReferenceAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080ReferenceAlarmEntry 2 }
pt3080ReferenceAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ReferenceAlarm state condition"
::= { pt3080ReferenceAlarmEntry 3 }
pt3080ReferenceAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080ReferenceAlarmEntry 4 }
pt3080ReferenceAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080ReferenceAlarmEntry 5 }
pt3080ReferenceAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080ReferenceAlarmEntry 6 }
pt3080ReferenceAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080ReferenceAlarmEntry 7 }
pt3080ReferenceAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080ReferenceAlarmEntry 8 }
pt3080ReferenceAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080ReferenceAlarmEntry 9 }
pt3080ReferenceAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080ReferenceAlarmEntry 10 }
-- RF Alarm table --
pt3080RFAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080RFAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the RF alarms"
::= { pt3080Alarm 9 }
pt3080RFAlarmEntry OBJECT-TYPE
SYNTAX Pt3080RFAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080RFAlarmID }
::= { pt3080RFAlarmTable 1 }
Pt3080RFAlarmEntry ::= SEQUENCE {
pt3080RFAlarmID Integer32,
pt3080RFAlarmDescription DisplayString,
pt3080RFAlarmState INTEGER,
pt3080RFAlarmActionEventlog INTEGER,
pt3080RFAlarmActionRelay1 INTEGER,
pt3080RFAlarmActionRelay2 INTEGER,
pt3080RFAlarmActionTrap INTEGER,
pt3080RFAlarmActionEmail INTEGER,
pt3080RFAlarmActionAlarmLED INTEGER,
pt3080RFAlarmActionForceMode INTEGER
}
pt3080RFAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080RFAlarmEntry 1 }
pt3080RFAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080RFAlarmEntry 2 }
pt3080RFAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current RFAlarm state condition"
::= { pt3080RFAlarmEntry 3 }
pt3080RFAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080RFAlarmEntry 4 }
pt3080RFAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080RFAlarmEntry 5 }
pt3080RFAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080RFAlarmEntry 6 }
pt3080RFAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080RFAlarmEntry 7 }
pt3080RFAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080RFAlarmEntry 8 }
pt3080RFAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080RFAlarmEntry 9 }
pt3080RFAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080RFAlarmEntry 10 }
-- GPS Alarm table --
pt3080GPSAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080GPSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the GPS alarms"
::= { pt3080Alarm 10 }
pt3080GPSAlarmEntry OBJECT-TYPE
SYNTAX Pt3080GPSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080GPSAlarmID }
::= { pt3080GPSAlarmTable 1 }
Pt3080GPSAlarmEntry ::= SEQUENCE {
pt3080GPSAlarmID Integer32,
pt3080GPSAlarmDescription DisplayString,
pt3080GPSAlarmState INTEGER,
pt3080GPSAlarmActionEventlog INTEGER,
pt3080GPSAlarmActionRelay1 INTEGER,
pt3080GPSAlarmActionRelay2 INTEGER,
pt3080GPSAlarmActionTrap INTEGER,
pt3080GPSAlarmActionEmail INTEGER,
pt3080GPSAlarmActionAlarmLED INTEGER,
pt3080GPSAlarmActionForceMode INTEGER
}
pt3080GPSAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080GPSAlarmEntry 1 }
pt3080GPSAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080GPSAlarmEntry 2 }
pt3080GPSAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current GPSAlarm state condition"
::= { pt3080GPSAlarmEntry 3 }
pt3080GPSAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080GPSAlarmEntry 4 }
pt3080GPSAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080GPSAlarmEntry 5 }
pt3080GPSAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080GPSAlarmEntry 6 }
pt3080GPSAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080GPSAlarmEntry 7 }
pt3080GPSAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080GPSAlarmEntry 8 }
pt3080GPSAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080GPSAlarmEntry 9 }
pt3080GPSAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080GPSAlarmEntry 10 }
-- TSoIP Alarm table --
pt3080TSoIPAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080TSoIPAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the TSoIP alarms"
::= { pt3080Alarm 12 }
pt3080TSoIPAlarmEntry OBJECT-TYPE
SYNTAX Pt3080TSoIPAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080TSoIPAlarmID }
::= { pt3080TSoIPAlarmTable 1 }
Pt3080TSoIPAlarmEntry ::= SEQUENCE {
pt3080TSoIPAlarmID Integer32,
pt3080TSoIPAlarmDescription DisplayString,
pt3080TSoIPAlarmState INTEGER,
pt3080TSoIPAlarmActionEventlog INTEGER,
pt3080TSoIPAlarmActionRelay1 INTEGER,
pt3080TSoIPAlarmActionRelay2 INTEGER,
pt3080TSoIPAlarmActionTrap INTEGER,
pt3080TSoIPAlarmActionEmail INTEGER,
pt3080TSoIPAlarmActionAlarmLED INTEGER,
pt3080TSoIPAlarmActionForceMode INTEGER
}
pt3080TSoIPAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080TSoIPAlarmEntry 1 }
pt3080TSoIPAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080TSoIPAlarmEntry 2 }
pt3080TSoIPAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current TSoIPAlarm state condition"
::= { pt3080TSoIPAlarmEntry 3 }
pt3080TSoIPAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080TSoIPAlarmEntry 4 }
pt3080TSoIPAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080TSoIPAlarmEntry 5 }
pt3080TSoIPAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080TSoIPAlarmEntry 6 }
pt3080TSoIPAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080TSoIPAlarmEntry 7 }
pt3080TSoIPAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080TSoIPAlarmEntry 8 }
pt3080TSoIPAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080TSoIPAlarmEntry 9 }
pt3080TSoIPAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080TSoIPAlarmEntry 10 }
-- External Alarm table --
pt3080ExternalAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080ExternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the External alarms"
::= { pt3080Alarm 13 }
pt3080ExternalAlarmEntry OBJECT-TYPE
SYNTAX Pt3080ExternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080ExternalAlarmID }
::= { pt3080ExternalAlarmTable 1 }
Pt3080ExternalAlarmEntry ::= SEQUENCE {
pt3080ExternalAlarmID Integer32,
pt3080ExternalAlarmDescription DisplayString,
pt3080ExternalAlarmState INTEGER,
pt3080ExternalAlarmActionEventlog INTEGER,
pt3080ExternalAlarmActionRelay1 INTEGER,
pt3080ExternalAlarmActionRelay2 INTEGER,
pt3080ExternalAlarmActionTrap INTEGER,
pt3080ExternalAlarmActionEmail INTEGER,
pt3080ExternalAlarmActionAlarmLED INTEGER,
pt3080ExternalAlarmActionForceMode INTEGER
}
pt3080ExternalAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080ExternalAlarmEntry 1 }
pt3080ExternalAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080ExternalAlarmEntry 2 }
pt3080ExternalAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ExternalAlarm state condition"
::= { pt3080ExternalAlarmEntry 3 }
pt3080ExternalAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080ExternalAlarmEntry 4 }
pt3080ExternalAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080ExternalAlarmEntry 5 }
pt3080ExternalAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080ExternalAlarmEntry 6 }
pt3080ExternalAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080ExternalAlarmEntry 7 }
pt3080ExternalAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080ExternalAlarmEntry 8 }
pt3080ExternalAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080ExternalAlarmEntry 9 }
pt3080ExternalAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080ExternalAlarmEntry 10 }
-- HW Monitor Alarm table --
pt3080HWMonitorAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080HWMonitorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the HW Monitor alarms"
::= { pt3080Alarm 14 }
pt3080HWMonitorAlarmEntry OBJECT-TYPE
SYNTAX Pt3080HWMonitorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080HWMonitorAlarmID }
::= { pt3080HWMonitorAlarmTable 1 }
Pt3080HWMonitorAlarmEntry ::= SEQUENCE {
pt3080HWMonitorAlarmID Integer32,
pt3080HWMonitorAlarmDescription DisplayString,
pt3080HWMonitorAlarmState INTEGER,
pt3080HWMonitorAlarmActionEventlog INTEGER,
pt3080HWMonitorAlarmActionRelay1 INTEGER,
pt3080HWMonitorAlarmActionRelay2 INTEGER,
pt3080HWMonitorAlarmActionTrap INTEGER,
pt3080HWMonitorAlarmActionEmail INTEGER,
pt3080HWMonitorAlarmActionAlarmLED INTEGER,
pt3080HWMonitorAlarmActionForceMode INTEGER
}
pt3080HWMonitorAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080HWMonitorAlarmEntry 1 }
pt3080HWMonitorAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080HWMonitorAlarmEntry 2 }
pt3080HWMonitorAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current HWMonitorAlarm state condition"
::= { pt3080HWMonitorAlarmEntry 3 }
pt3080HWMonitorAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080HWMonitorAlarmEntry 4 }
pt3080HWMonitorAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080HWMonitorAlarmEntry 5 }
pt3080HWMonitorAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080HWMonitorAlarmEntry 6 }
pt3080HWMonitorAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080HWMonitorAlarmEntry 7 }
pt3080HWMonitorAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080HWMonitorAlarmEntry 8 }
pt3080HWMonitorAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080HWMonitorAlarmEntry 9 }
pt3080HWMonitorAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080HWMonitorAlarmEntry 10 }
-- Communications Alarm table --
pt3080CommsAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080CommsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Communication alarms"
::= { pt3080Alarm 15 }
pt3080CommsAlarmEntry OBJECT-TYPE
SYNTAX Pt3080CommsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080CommsAlarmID }
::= { pt3080CommsAlarmTable 1 }
Pt3080CommsAlarmEntry ::= SEQUENCE {
pt3080CommsAlarmID Integer32,
pt3080CommsAlarmDescription DisplayString,
pt3080CommsAlarmState INTEGER,
pt3080CommsAlarmActionEventlog INTEGER,
pt3080CommsAlarmActionRelay1 INTEGER,
pt3080CommsAlarmActionRelay2 INTEGER,
pt3080CommsAlarmActionTrap INTEGER,
pt3080CommsAlarmActionEmail INTEGER,
pt3080CommsAlarmActionAlarmLED INTEGER,
pt3080CommsAlarmActionForceMode INTEGER
}
pt3080CommsAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080CommsAlarmEntry 1 }
pt3080CommsAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080CommsAlarmEntry 2 }
pt3080CommsAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current CommsAlarm state condition"
::= { pt3080CommsAlarmEntry 3 }
pt3080CommsAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080CommsAlarmEntry 4 }
pt3080CommsAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080CommsAlarmEntry 5 }
pt3080CommsAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080CommsAlarmEntry 6 }
pt3080CommsAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080CommsAlarmEntry 7 }
pt3080CommsAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080CommsAlarmEntry 8 }
pt3080CommsAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080CommsAlarmEntry 9 }
pt3080CommsAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080CommsAlarmEntry 10 }
-- ASI Alarm table --
pt3080ASIAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080ASIAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the ASI alarms"
::= { pt3080Alarm 16 }
pt3080ASIAlarmEntry OBJECT-TYPE
SYNTAX Pt3080ASIAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080ASIAlarmID }
::= { pt3080ASIAlarmTable 1 }
Pt3080ASIAlarmEntry ::= SEQUENCE {
pt3080ASIAlarmID Integer32,
pt3080ASIAlarmDescription DisplayString,
pt3080ASIAlarmState INTEGER,
pt3080ASIAlarmActionEventlog INTEGER,
pt3080ASIAlarmActionRelay1 INTEGER,
pt3080ASIAlarmActionRelay2 INTEGER,
pt3080ASIAlarmActionTrap INTEGER,
pt3080ASIAlarmActionEmail INTEGER,
pt3080ASIAlarmActionAlarmLED INTEGER,
pt3080ASIAlarmActionForceMode INTEGER
}
pt3080ASIAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080ASIAlarmEntry 1 }
pt3080ASIAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080ASIAlarmEntry 2 }
pt3080ASIAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ASIAlarm state condition"
::= { pt3080ASIAlarmEntry 3 }
pt3080ASIAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080ASIAlarmEntry 4 }
pt3080ASIAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080ASIAlarmEntry 5 }
pt3080ASIAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080ASIAlarmEntry 6 }
pt3080ASIAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080ASIAlarmEntry 7 }
pt3080ASIAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080ASIAlarmEntry 8 }
pt3080ASIAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080ASIAlarmEntry 9 }
pt3080ASIAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080ASIAlarmEntry 10 }
-- Demodulator Alarm table --
pt3080DemodulatorAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080DemodulatorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Demodulator alarms"
::= { pt3080Alarm 17 }
pt3080DemodulatorAlarmEntry OBJECT-TYPE
SYNTAX Pt3080DemodulatorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080DemodulatorAlarmID }
::= { pt3080DemodulatorAlarmTable 1 }
Pt3080DemodulatorAlarmEntry ::= SEQUENCE {
pt3080DemodulatorAlarmID Integer32,
pt3080DemodulatorAlarmDescription DisplayString,
pt3080DemodulatorAlarmState INTEGER,
pt3080DemodulatorAlarmActionEventlog INTEGER,
pt3080DemodulatorAlarmActionRelay1 INTEGER,
pt3080DemodulatorAlarmActionRelay2 INTEGER,
pt3080DemodulatorAlarmActionTrap INTEGER,
pt3080DemodulatorAlarmActionEmail INTEGER,
pt3080DemodulatorAlarmActionAlarmLED INTEGER,
pt3080DemodulatorAlarmActionForceMode INTEGER
}
pt3080DemodulatorAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080DemodulatorAlarmEntry 1 }
pt3080DemodulatorAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080DemodulatorAlarmEntry 2 }
pt3080DemodulatorAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current DemodulatorAlarm state condition"
::= { pt3080DemodulatorAlarmEntry 3 }
pt3080DemodulatorAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080DemodulatorAlarmEntry 4 }
pt3080DemodulatorAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080DemodulatorAlarmEntry 5 }
pt3080DemodulatorAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080DemodulatorAlarmEntry 6 }
pt3080DemodulatorAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080DemodulatorAlarmEntry 7 }
pt3080DemodulatorAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080DemodulatorAlarmEntry 8 }
pt3080DemodulatorAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080DemodulatorAlarmEntry 9 }
pt3080DemodulatorAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080DemodulatorAlarmEntry 10 }
-- Internal Alarm table --
pt3080InternalAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080InternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Internal alarms"
::= { pt3080Alarm 18 }
pt3080InternalAlarmEntry OBJECT-TYPE
SYNTAX Pt3080InternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080InternalAlarmID }
::= { pt3080InternalAlarmTable 1 }
Pt3080InternalAlarmEntry ::= SEQUENCE {
pt3080InternalAlarmID Integer32,
pt3080InternalAlarmDescription DisplayString,
pt3080InternalAlarmState INTEGER,
pt3080InternalAlarmActionEventlog INTEGER,
pt3080InternalAlarmActionRelay1 INTEGER,
pt3080InternalAlarmActionRelay2 INTEGER,
pt3080InternalAlarmActionTrap INTEGER,
pt3080InternalAlarmActionEmail INTEGER,
pt3080InternalAlarmActionAlarmLED INTEGER,
pt3080InternalAlarmActionForceMode INTEGER
}
pt3080InternalAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { pt3080InternalAlarmEntry 1 }
pt3080InternalAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { pt3080InternalAlarmEntry 2 }
pt3080InternalAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current InternalAlarm state condition"
::= { pt3080InternalAlarmEntry 3 }
pt3080InternalAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { pt3080InternalAlarmEntry 4 }
pt3080InternalAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { pt3080InternalAlarmEntry 5 }
pt3080InternalAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { pt3080InternalAlarmEntry 6 }
pt3080InternalAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { pt3080InternalAlarmEntry 7 }
pt3080InternalAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { pt3080InternalAlarmEntry 8 }
pt3080InternalAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { pt3080InternalAlarmEntry 9 }
pt3080InternalAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { pt3080InternalAlarmEntry 10 }
-- DVB-T2 Mode-A Alarm table --
--
-- pt3080 Preset sub-tree
--
pt3080PresetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080PresetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the presets"
::= { pt3080Preset 1 }
pt3080PresetEntry OBJECT-TYPE
SYNTAX Pt3080PresetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the presets"
INDEX { pt3080PresetNo }
::= { pt3080PresetTable 1 }
Pt3080PresetEntry ::= SEQUENCE {
pt3080PresetNo Integer32,
pt3080PresetName DisplayString
}
pt3080PresetNo OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 10 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique number for this preset"
::= { pt3080PresetEntry 1 }
pt3080PresetName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this preset"
::= { pt3080PresetEntry 2 }
pt3080PresetRecall OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Install this preset into current running parameter set.
Value will always read as 0 and setting it to 0 has no effect."
::= { pt3080Preset 2 }
pt3080PresetStore OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 8 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Store the currently running parameter set into this preset
Value will always read as 0 and setting it to 0 has no effect."
::= { pt3080Preset 3 }
--
-- pt3080 Eventlog sub-tree
--
pt3080EventlogTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080EventlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the group alarms"
::= { pt3080Eventlog 1 }
pt3080EventlogEntry OBJECT-TYPE
SYNTAX Pt3080EventlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { pt3080EventlogNo }
::= { pt3080EventlogTable 1 }
Pt3080EventlogEntry ::= SEQUENCE {
pt3080EventlogNo Integer32,
pt3080EventlogID Integer32,
pt3080EventlogTimestamp DateAndTime,
pt3080EventlogText DisplayString
}
pt3080EventlogNo OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2047 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique number for this event"
::= { pt3080EventlogEntry 1 }
pt3080EventlogID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique ID for this type of event"
::= { pt3080EventlogEntry 2 }
pt3080EventlogTimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp for this event"
::= { pt3080EventlogEntry 3 }
pt3080EventlogText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Text for this event"
::= { pt3080EventlogEntry 4 }
pt3080EventlogClear OBJECT-TYPE
SYNTAX INTEGER { noop(0), clear(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the entire eventlog by setting the value to 1."
::= { pt3080Eventlog 2 }
pt3080EventlogEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable eventlog by setting the value to 1."
::= { pt3080Eventlog 3 }
pt3080EventlogMode OBJECT-TYPE
SYNTAX INTEGER { fifo(0), full(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set eventlog mode to FIFO for keeping the newest entries.
Set eventlog mode to FULL for keeping the oldest entries."
::= { pt3080Eventlog 4 }
--
-- pt3080 Comms sub-tree
--
pt3080CommsAlarmEmailReceiver OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The email address of the receipiant of alarm emails."
::= { pt3080Comms 34 }
pt3080CommsSeparatedSwitchPorts OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the ports on the switch in the backplane forward LAN traffic
to each other or will they be separated and only forward traffic
to/from the modulator/repeater."
::= { pt3080Comms 98 }
pt3080CommsBroadcastStormProtection OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable broadcast (and multicast) storm Protection. This
will limit the network ingress rate on physical Ethernet port
0 and 1 to roughly 100mbit/s."
::= { pt3080Comms 94 }
pt3080CommsLocalPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { pt3080Comms 80 }
pt3080CommsLocalDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { pt3080Comms 3 }
pt3080CommsLocalStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 1 }
pt3080CommsLocalStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 2 }
pt3080CommsLocalIpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast address for this interface."
::= { pt3080Comms 100 }
pt3080CommsLocalIpMulticastSourceFilterMode OBJECT-TYPE
SYNTAX INTEGER { sfinclude(0), sfexclude(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether the Multicast Source Filter IP Address list
is: SFINCLUDE: ONLY receive multicast frames from the source
addresses in the list. SFEXCLUDE: Receive all multicast frames
EXCEPT from the source addresses in the list."
::= { pt3080Comms 190 }
pt3080CommsLocalIpMulticastSourceFilterAddress1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 1 for this interface."
::= { pt3080Comms 200 }
pt3080CommsLocalIpMulticastSourceFilterAddress2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 2 for this interface."
::= { pt3080Comms 201 }
pt3080CommsLocalIpMulticastSourceFilterAddress3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 3 for this interface."
::= { pt3080Comms 202 }
pt3080CommsLocalIpMulticastSourceFilterAddress4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 4 for this interface."
::= { pt3080Comms 203 }
pt3080CommsLocalIpMulticastSourceFilterAddress5 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 5 for this interface."
::= { pt3080Comms 204 }
pt3080CommsLocalIpMulticastSourceFilterAddress6 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 6 for this interface."
::= { pt3080Comms 205 }
pt3080CommsLocalVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { pt3080Comms 101 }
pt3080CommsLocalVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { pt3080Comms 102 }
pt3080CommsLocalServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { pt3080Comms 103 }
pt3080CommsLocalServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { pt3080Comms 104 }
pt3080CommsLocalServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { pt3080Comms 105 }
pt3080CommsLocalServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { pt3080Comms 106 }
pt3080CommsLocalCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { pt3080Comms 4 }
pt3080CommsLocalCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { pt3080Comms 5 }
pt3080CommsRemoteEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { pt3080Comms 117 }
pt3080CommsRemotePhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { pt3080Comms 81 }
pt3080CommsRemoteDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { pt3080Comms 73 }
pt3080CommsRemoteStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 7 }
pt3080CommsRemoteStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 8 }
pt3080CommsRemoteIpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast address for this interface."
::= { pt3080Comms 110 }
pt3080CommsRemoteIpMulticastSourceFilterMode OBJECT-TYPE
SYNTAX INTEGER { sfinclude(0), sfexclude(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether the Multicast Source Filter IP Address list
is: SFINCLUDE: ONLY receive multicast frames from the source
addresses in the list. SFEXCLUDE: Receive all multicast frames
EXCEPT from the source addresses in the list."
::= { pt3080Comms 191 }
pt3080CommsRemoteIpMulticastSourceFilterAddress1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 1 for this interface."
::= { pt3080Comms 220 }
pt3080CommsRemoteIpMulticastSourceFilterAddress2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 2 for this interface."
::= { pt3080Comms 221 }
pt3080CommsRemoteIpMulticastSourceFilterAddress3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 3 for this interface."
::= { pt3080Comms 222 }
pt3080CommsRemoteIpMulticastSourceFilterAddress4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 4 for this interface."
::= { pt3080Comms 223 }
pt3080CommsRemoteIpMulticastSourceFilterAddress5 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 5 for this interface."
::= { pt3080Comms 224 }
pt3080CommsRemoteIpMulticastSourceFilterAddress6 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 6 for this interface."
::= { pt3080Comms 225 }
pt3080CommsRemoteVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { pt3080Comms 111 }
pt3080CommsRemoteVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { pt3080Comms 112 }
pt3080CommsRemoteServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { pt3080Comms 113 }
pt3080CommsRemoteServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { pt3080Comms 114 }
pt3080CommsRemoteServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { pt3080Comms 115 }
pt3080CommsRemoteServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable WEB (http) service on this interface."
::= { pt3080Comms 116 }
pt3080CommsRemoteServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { pt3080Comms 118 }
pt3080CommsRemoteCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { pt3080Comms 10 }
pt3080CommsRemoteCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { pt3080Comms 11 }
pt3080CommsGbeAdminEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { pt3080Comms 127 }
pt3080CommsGbeAdminPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { pt3080Comms 82 }
pt3080CommsGbeAdminDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { pt3080Comms 74 }
pt3080CommsGbeAdminStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 13 }
pt3080CommsGbeAdminStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 14 }
pt3080CommsGbeAdminIpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast address for this interface."
::= { pt3080Comms 120 }
pt3080CommsGbeAdminIpMulticastSourceFilterMode OBJECT-TYPE
SYNTAX INTEGER { sfinclude(0), sfexclude(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether the Multicast Source Filter IP Address list
is: SFINCLUDE: ONLY receive multicast frames from the source
addresses in the list. SFEXCLUDE: Receive all multicast frames
EXCEPT from the source addresses in the list."
::= { pt3080Comms 192 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 1 for this interface."
::= { pt3080Comms 230 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 2 for this interface."
::= { pt3080Comms 231 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 3 for this interface."
::= { pt3080Comms 232 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 4 for this interface."
::= { pt3080Comms 233 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress5 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 5 for this interface."
::= { pt3080Comms 234 }
pt3080CommsGbeAdminIpMulticastSourceFilterAddress6 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 6 for this interface."
::= { pt3080Comms 235 }
pt3080CommsGbeAdminVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { pt3080Comms 121 }
pt3080CommsGbeAdminVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { pt3080Comms 122 }
pt3080CommsGbeAdminServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { pt3080Comms 123 }
pt3080CommsGbeAdminServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { pt3080Comms 124 }
pt3080CommsGbeAdminServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { pt3080Comms 125 }
pt3080CommsGbeAdminServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { pt3080Comms 126 }
pt3080CommsGbeAdminServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { pt3080Comms 128 }
pt3080CommsGbeAdminCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { pt3080Comms 16 }
pt3080CommsGbeAdminCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { pt3080Comms 17 }
pt3080CommsBackupEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { pt3080Comms 150 }
pt3080CommsBackupPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { pt3080Comms 151 }
pt3080CommsBackupDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { pt3080Comms 75 }
pt3080CommsBackupStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 152 }
pt3080CommsBackupStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 153 }
pt3080CommsBackupIpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast address for this interface."
::= { pt3080Comms 154 }
pt3080CommsBackupIpMulticastSourceFilterMode OBJECT-TYPE
SYNTAX INTEGER { sfinclude(0), sfexclude(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether the Multicast Source Filter IP Address list
is: SFINCLUDE: ONLY receive multicast frames from the source
addresses in the list. SFEXCLUDE: Receive all multicast frames
EXCEPT from the source addresses in the list."
::= { pt3080Comms 193 }
pt3080CommsBackupIpMulticastSourceFilterAddress1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 1 for this interface."
::= { pt3080Comms 170 }
pt3080CommsBackupIpMulticastSourceFilterAddress2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 2 for this interface."
::= { pt3080Comms 171 }
pt3080CommsBackupIpMulticastSourceFilterAddress3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 3 for this interface."
::= { pt3080Comms 172 }
pt3080CommsBackupIpMulticastSourceFilterAddress4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 4 for this interface."
::= { pt3080Comms 173 }
pt3080CommsBackupIpMulticastSourceFilterAddress5 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 5 for this interface."
::= { pt3080Comms 174 }
pt3080CommsBackupIpMulticastSourceFilterAddress6 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 6 for this interface."
::= { pt3080Comms 175 }
pt3080CommsBackupVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { pt3080Comms 155 }
pt3080CommsBackupVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { pt3080Comms 156 }
pt3080CommsBackupServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { pt3080Comms 157 }
pt3080CommsBackupServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { pt3080Comms 158 }
pt3080CommsBackupServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { pt3080Comms 159 }
pt3080CommsBackupServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { pt3080Comms 160 }
pt3080CommsBackupServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { pt3080Comms 161 }
pt3080CommsBackupCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { pt3080Comms 162 }
pt3080CommsBackupCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { pt3080Comms 163 }
pt3080CommsPortEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { pt3080Comms 2500 }
pt3080CommsPortPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { pt3080Comms 2151 }
pt3080CommsPortDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { pt3080Comms 2075 }
pt3080CommsPortStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 2152 }
pt3080CommsPortStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 2153 }
pt3080CommsPortIpMulticastAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast address for this interface."
::= { pt3080Comms 2154 }
pt3080CommsPortIpMulticastSourceFilterMode OBJECT-TYPE
SYNTAX INTEGER { sfinclude(0), sfexclude(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether the Multicast Source Filter IP Address list
is: SFINCLUDE: ONLY receive multicast frames from the source
addresses in the list. SFEXCLUDE: Receive all multicast frames
EXCEPT from the source addresses in the list."
::= { pt3080Comms 2193 }
pt3080CommsPortIpMulticastSourceFilterAddress1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 1 for this interface."
::= { pt3080Comms 2170 }
pt3080CommsPortIpMulticastSourceFilterAddress2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 2 for this interface."
::= { pt3080Comms 2171 }
pt3080CommsPortIpMulticastSourceFilterAddress3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 3 for this interface."
::= { pt3080Comms 2172 }
pt3080CommsPortIpMulticastSourceFilterAddress4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 4 for this interface."
::= { pt3080Comms 2173 }
pt3080CommsPortIpMulticastSourceFilterAddress5 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 5 for this interface."
::= { pt3080Comms 2174 }
pt3080CommsPortIpMulticastSourceFilterAddress6 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP Multicast Source Filter address no 6 for this interface."
::= { pt3080Comms 2175 }
pt3080CommsPortVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { pt3080Comms 2155 }
pt3080CommsPortVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { pt3080Comms 2156 }
pt3080CommsPortServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { pt3080Comms 2157 }
pt3080CommsPortServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { pt3080Comms 2158 }
pt3080CommsPortServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { pt3080Comms 2159 }
pt3080CommsPortServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { pt3080Comms 2160 }
pt3080CommsPortServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { pt3080Comms 2161 }
pt3080CommsPortCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { pt3080Comms 2162 }
pt3080CommsPortCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { pt3080Comms 2163 }
pt3080CommsSNMPServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for SNMP Service."
::= { pt3080Comms 55 }
pt3080CommsSNMPReadOnlyCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Read-only community string used to access the SNMP Service."
::= { pt3080Comms 56 }
pt3080CommsSNMPReadWriteCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Read-Write community string used to access the SNMP Service."
::= { pt3080Comms 57 }
pt3080CommsSNMPTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Trap community string used when sending SNMP Traps."
::= { pt3080Comms 58 }
pt3080CommsSNMPTrapDestination OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination IP address for the SNMP traps."
::= { pt3080Comms 59 }
pt3080CommsSNMPTrapDestination2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 2 IP address for the SNMP traps."
::= { pt3080Comms 419 }
pt3080CommsSNMPTrapDestination3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 3 IP address for the SNMP traps."
::= { pt3080Comms 779 }
pt3080CommsSNMPTrapDestination4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 4 IP address for the SNMP traps."
::= { pt3080Comms 1139 }
pt3080CommsSNMPTrapDestination5 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 5 IP address for the SNMP traps."
::= { pt3080Comms 1499 }
pt3080CommsSNMPTrapDestinationPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination ."
::= { pt3080Comms 60 }
pt3080CommsSNMPTrapDestinationPort2 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 2."
::= { pt3080Comms 420 }
pt3080CommsSNMPTrapDestinationPort3 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 3."
::= { pt3080Comms 780 }
pt3080CommsSNMPTrapDestinationPort4 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 4."
::= { pt3080Comms 1140 }
pt3080CommsSNMPTrapDestinationPort5 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 5."
::= { pt3080Comms 1500 }
pt3080CommsStaticGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for the default router (gateway). Will
be used unless DHCP is enabled and the DHCP server is configured
to include a default router address."
::= { pt3080Comms 29 }
pt3080CommsCurrentGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address for the default router (gateway)."
::= { pt3080Comms 30 }
pt3080CommsStaticHostname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static hostname for the device. Will be used if DHCP is
disabled or unavailable."
::= { pt3080Comms 27 }
pt3080CommsCurrentHostname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The static hostname for the device. Will be used if DHCP is
disabled or unavailable."
::= { pt3080Comms 28 }
pt3080CommsStaticDNSDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static DNS domain name for the device. Will be used if DHCP
is disabled or unavailable."
::= { pt3080Comms 25 }
pt3080CommsCurrentDNSDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current DNS domain name for the device."
::= { pt3080Comms 26 }
pt3080CommsStaticDNS1ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 1."
::= { pt3080Comms 19 }
pt3080CommsStaticDNS2ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 2."
::= { pt3080Comms 21 }
pt3080CommsStaticDNS3ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 3."
::= { pt3080Comms 23 }
pt3080CommsCurrentDNS1ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 1."
::= { pt3080Comms 20 }
pt3080CommsCurrentDNS2ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 2."
::= { pt3080Comms 22 }
pt3080CommsCurrentDNS3ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 3."
::= { pt3080Comms 24 }
pt3080CommsStaticNtpServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DNS name or IP address of the NTP server."
::= { pt3080Comms 31 }
pt3080CommsCurrentNtpServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of the NTP server."
::= { pt3080Comms 32 }
pt3080CommsEmailServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the Email (SMTP) server."
::= { pt3080Comms 33 }
pt3080CommsWebServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number used for Web Service."
::= { pt3080Comms 35 }
pt3080CommsSCPIServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number used for SCPI Service."
::= { pt3080Comms 36 }
pt3080CommsSCPIServerBaudrate OBJECT-TYPE
SYNTAX INTEGER { r2400(0), r4800(1), r9600(2), r19200(3), r38400(4), r57600(5), r115200(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Baudrate used for SCPI Service on serial port."
::= { pt3080Comms 37 }
pt3080CommsSCPIUartInterface OBJECT-TYPE
SYNTAX INTEGER { rs232(0), rs485(1), rs485hd(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Interface used for SCPI Service on serial port."
::= { pt3080Comms 39 }
pt3080CommsRipPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for RIP Service."
::= { pt3080Comms 38 }
pt3080CommsIGMPVersion OBJECT-TYPE
SYNTAX INTEGER { auto(0), v1(1), v2(2), v3(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select which IGMP Version to use."
::= { pt3080Comms 99 }
pt3080CommsIGMPQueryRobustnessCount OBJECT-TYPE
SYNTAX Integer32 ( 2 .. 16 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Number of Query Replies sent. The higher a number, the more
robust IGMP setup is. At the cost of traffic on the network.
Note: Changing this parameter doesnt take effect on a network
interface until it has (re-)enabled."
::= { pt3080Comms 97 }
pt3080CommsIGMPv3UnsolicitedReportInterval OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 60000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval between unsolicited IGMPv3 reports being sent.
See RFC3376. The number of such report being sent is controlled
by the Query Robustness Count."
::= { pt3080Comms 96 }
pt3080CommsIGMPv2UnsolicitedReportInterval OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 60000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval between unsolicited IGMPv2/v1 reports being
sent. See RFC2236. The number of such report being sent is
controlled by the Query Robustness Count."
::= { pt3080Comms 95 }
pt3080CommsAccessAllowed OBJECT-TYPE
SYNTAX INTEGER { remote(0), local-disable-set(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Current access mode allowed: Remote: SNMP via Ethernet, Local:
Frontpanel"
::= { pt3080Comms 48 }
pt3080CommsAccessAllowedTimeout OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1440 )
UNITS "1 min"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout (in minutes) before local mode reverts to remote mode."
::= { pt3080Comms 49 }
pt3080CommsAccessAllowedTimeLeft OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current time left (in seconds) before local mode reverts to
remote mode."
::= { pt3080Comms 50 }
pt3080CommsAccessPasswordObserver OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Observer level access. Will always read as empty."
::= { pt3080Comms 51 }
pt3080CommsAccessPasswordOperator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Operator level access. Will always read as empty."
::= { pt3080Comms 52 }
pt3080CommsAccessPasswordAdministrator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Administrator level access. Will always read as empty."
::= { pt3080Comms 53 }
pt3080CommsStaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF Pt3080CommsStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the static routing table entries"
::= { pt3080Comms 300 }
pt3080CommsStaticRouteEntry OBJECT-TYPE
SYNTAX Pt3080CommsStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the static network routing table"
INDEX { pt3080CommsStaticRouteNO }
::= { pt3080CommsStaticRouteTable 1 }
Pt3080CommsStaticRouteEntry ::= SEQUENCE {
pt3080CommsStaticRouteNO Integer32,
pt3080CommsStaticRouteType INTEGER,
pt3080CommsStaticRoutePrefix IpAddress,
pt3080CommsStaticRoutePrefixSize Integer32,
pt3080CommsStaticRouteTarget IpAddress,
pt3080CommsStaticRoutePhysicalInterface INTEGER
}
pt3080CommsStaticRouteNO OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 16 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this static route entry"
::= { pt3080CommsStaticRouteEntry 1 }
pt3080CommsStaticRouteType OBJECT-TYPE
SYNTAX INTEGER { unused(0), normal(1), physicalif(2), recursive(3), drop(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of a Route table entry."
::= { pt3080CommsStaticRouteEntry 2 }
pt3080CommsStaticRoutePrefix OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address part of prefix for a route table entry.
If the address is 0.0.0.0, the entry will not be used."
::= { pt3080CommsStaticRouteEntry 3 }
pt3080CommsStaticRoutePrefixSize OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 32 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of bits in the network part of the prefix for route table entry $.
If the number is 0 (zero), the entry will not be used."
::= { pt3080CommsStaticRouteEntry 4 }
pt3080CommsStaticRouteTarget OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The target IP address for a route table entry.
Only used if pt3080CommsStaticRouteType is normal(1) or recursive(3).
If the target address is 0.0.0.0, the entry will not be used."
::= { pt3080CommsStaticRouteEntry 5 }
pt3080CommsStaticRoutePhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface to use for a Route table entry.
Only used when pt3080CommsStaticRouteType is physicalif(2)."
::= { pt3080CommsStaticRouteEntry 6 }
--
-- pt3080 Demodulator sub-tree
--
pt3080DemodulatorFollowMode OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the Demodulators follow mode."
::= { pt3080Demodulator 1 }
pt3080Demodulator1Available OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status on the availability of Demodulator 1"
::= { pt3080Demodulator 2 }
pt3080Demodulator2Available OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status on the availability of Demodulator 2"
::= { pt3080Demodulator 29 }
pt3080Demodulator1FWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator 1 firmware version string"
::= { pt3080Demodulator 3 }
pt3080Demodulator2FWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Demodulator 2 firmware version string"
::= { pt3080Demodulator 30 }
pt3080Demodulator1OutputTS OBJECT-TYPE
SYNTAX INTEGER { hp(0), lp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which TS demodulator 1 shall output"
::= { pt3080Demodulator 4 }
pt3080Demodulator2OutputTS OBJECT-TYPE
SYNTAX INTEGER { hp(0), lp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which TS demodulator 2 shall output"
::= { pt3080Demodulator 31 }
pt3080Demodulator1MerLimit OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 240 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower limit for MER Level"
::= { pt3080Demodulator 5 }
pt3080Demodulator2MerLimit OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 240 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower limit for MER Level"
::= { pt3080Demodulator 32 }
pt3080Demodulator1PreVirterbiErrorRateLimit OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1000000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upper limit for Pre-Virterbi Bit Error Rate"
::= { pt3080Demodulator 6 }
pt3080Demodulator2PreVirterbiErrorRateLimit OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1000000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upper limit for Pre-Virterbi Bit Error Rate"
::= { pt3080Demodulator 33 }
pt3080Demodulator1PostVirterbiErrorRateLimit OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1000000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upper limit for Post-Virterbi Bit Error Rate"
::= { pt3080Demodulator 7 }
pt3080Demodulator2PostVirterbiErrorRateLimit OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1000000 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upper limit for Post-Virterbi Bit Error Rate"
::= { pt3080Demodulator 34 }
pt3080Demodulator1FelStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received signal locked status on Demodulator 1"
::= { pt3080Demodulator 8 }
pt3080Demodulator2FelStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Received signal locked status on Demodulator 2"
::= { pt3080Demodulator 35 }
pt3080Demodulator1UncorrectedPackets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of uncorrected packets received in Demodulator 1 since
boot or since counter was last cleared."
::= { pt3080Demodulator 9 }
pt3080Demodulator2UncorrectedPackets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of uncorrected packets received in Demodulator 2 since
boot or since counter was last cleared."
::= { pt3080Demodulator 36 }
pt3080Demodulator1Mer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current MER level for Demodulator 1"
::= { pt3080Demodulator 11 }
pt3080Demodulator2Mer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current MER level for Demodulator 2"
::= { pt3080Demodulator 38 }
pt3080Demodulator1PreVirterbiErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 x1e-7"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Pre-Virterbi Bit Error Rate for Demodulator 1"
::= { pt3080Demodulator 12 }
pt3080Demodulator2PreVirterbiErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 x1e-7"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Pre-Virterbi Bit Error Rate for Demodulator 2"
::= { pt3080Demodulator 39 }
pt3080Demodulator1PostVirterbiErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 x1e-7"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Post-Virterbi Bit Error Rate for Demodulator 1"
::= { pt3080Demodulator 13 }
pt3080Demodulator2PostVirterbiErrorRate OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 x1e-7"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Post-Virterbi Bit Error Rate for Demodulator 2"
::= { pt3080Demodulator 40 }
pt3080Demodulator1ActualGuardInterval OBJECT-TYPE
SYNTAX INTEGER { g1-32(0), g1-16(1), g1-8(2), g1-4(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Guard Interval for the received signal on Demodulator 1"
::= { pt3080Demodulator 14 }
pt3080Demodulator2ActualGuardInterval OBJECT-TYPE
SYNTAX INTEGER { g1-32(0), g1-16(1), g1-8(2), g1-4(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Guard Interval for the received signal on Demodulator 2"
::= { pt3080Demodulator 41 }
pt3080Demodulator1Actualifft OBJECT-TYPE
SYNTAX INTEGER { f2k(0), f4k(1), f8k(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IFFT for the received signal on Demodulator 1"
::= { pt3080Demodulator 15 }
pt3080Demodulator2Actualifft OBJECT-TYPE
SYNTAX INTEGER { f2k(0), f4k(1), f8k(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IFFT for the received signal on Demodulator 2"
::= { pt3080Demodulator 42 }
pt3080Demodulator1ActualConstellation OBJECT-TYPE
SYNTAX INTEGER { qpsk(0), qam16(1), qam64(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Constellation for the received signal on Demodulator 1"
::= { pt3080Demodulator 16 }
pt3080Demodulator2ActualConstellation OBJECT-TYPE
SYNTAX INTEGER { qpsk(0), qam16(1), qam64(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Constellation for the received signal on Demodulator 2"
::= { pt3080Demodulator 43 }
pt3080Demodulator1ActualHierarchy OBJECT-TYPE
SYNTAX INTEGER { none(0), h-1(1), h-2(2), h-4(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hierarchy for the received signal on Demodulator 1"
::= { pt3080Demodulator 17 }
pt3080Demodulator2ActualHierarchy OBJECT-TYPE
SYNTAX INTEGER { none(0), h-1(1), h-2(2), h-4(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hierarchy for the received signal on Demodulator 2"
::= { pt3080Demodulator 44 }
pt3080Demodulator1ActualCodeRateHighPrio OBJECT-TYPE
SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority Code Rate for the received signal on Demodulator
1"
::= { pt3080Demodulator 18 }
pt3080Demodulator2ActualCodeRateHighPrio OBJECT-TYPE
SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority Code Rate for the received signal on Demodulator
2"
::= { pt3080Demodulator 45 }
pt3080Demodulator1ActualCodeRateLowPrio OBJECT-TYPE
SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority Code Rate for the received signal on Demodulator
1"
::= { pt3080Demodulator 19 }
pt3080Demodulator2ActualCodeRateLowPrio OBJECT-TYPE
SYNTAX INTEGER { r1-2(0), r2-3(1), r3-4(2), r5-6(3), r7-8(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority Code Rate for the received signal on Demodulator
2"
::= { pt3080Demodulator 46 }
pt3080Demodulator1ActualDeepInterleaver OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Deep Interleaver for the received signal on Demodulator 1"
::= { pt3080Demodulator 20 }
pt3080Demodulator2ActualDeepInterleaver OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Deep Interleaver for the received signal on Demodulator 2"
::= { pt3080Demodulator 47 }
pt3080Demodulator1ActualMpeFecHighPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority MPE/FEC mode for the received signal on Demodulator
1"
::= { pt3080Demodulator 21 }
pt3080Demodulator2ActualMpeFecHighPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority MPE/FEC mode for the received signal on Demodulator
2"
::= { pt3080Demodulator 48 }
pt3080Demodulator1ActualMpeFecLowPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Priority MPE/FEC mode for the received signal on Demodulator
1"
::= { pt3080Demodulator 22 }
pt3080Demodulator2ActualMpeFecLowPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Priority MPE/FEC mode for the received signal on Demodulator
2"
::= { pt3080Demodulator 49 }
pt3080Demodulator1ActualTimeSlicingHighPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority timeslicing mode for the received signal on Demodulator
1"
::= { pt3080Demodulator 23 }
pt3080Demodulator2ActualTimeSlicingHighPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"High Priority timeslicing mode for the received signal on Demodulator
2"
::= { pt3080Demodulator 50 }
pt3080Demodulator1ActualTimeSlicingLowPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Priority timeslicing mode for the received signal on Demodulator
1"
::= { pt3080Demodulator 24 }
pt3080Demodulator2ActualTimeSlicingLowPrio OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Low Priority timeslicing mode for the received signal on Demodulator
2"
::= { pt3080Demodulator 51 }
pt3080Demodulator1ActualCellID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cell ID value for the received signal on Demodulator
1"
::= { pt3080Demodulator 25 }
pt3080Demodulator2ActualCellID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current Cell ID value for the received signal on Demodulator
1"
::= { pt3080Demodulator 52 }
pt3080Demodulator1ActualDVBHMode OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB-H mode for the received signal on Demodulator 1"
::= { pt3080Demodulator 26 }
pt3080Demodulator2ActualDVBHMode OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"DVB-H mode for the received signal on Demodulator 2"
::= { pt3080Demodulator 53 }
--
-- pt3080 Precorrector sub-tree
--
pt3080PrecorrectorLinearAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Linear precorrection curve active in the system"
::= { pt3080Precorrector 79 }
pt3080PrecorrectorLinearMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the linear precorrector
<br/>(note: legacy term used for backward compatibility. MONITORING
Equal to the mode named BYPASS in the WEB GUI )"
::= { pt3080Precorrector 2 }
pt3080PrecorrectorLinearSenseEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By using this, it is possible to control wether to use the linear
Sense Input or not."
::= { pt3080Precorrector 46 }
pt3080PrecorrectorLinearMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"linear Precor state"
::= { pt3080Precorrector 24 }
pt3080PrecorrectorLinearMonitorSenseLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level meassured at the linear sense input with offset defined
by attenuation"
::= { pt3080Precorrector 22 }
pt3080PrecorrectorLinearMonitorSenseValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is linear sense input information valid"
::= { pt3080Precorrector 23 }
pt3080PrecorrectorLinearMonitorSenseBadCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bad/invalid sense counts, made by the linear adaptive
precorrector."
::= { pt3080Precorrector 8 }
pt3080PrecorrectorLinearMonitorAmplitudeRipple OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amplitude ripple"
::= { pt3080Precorrector 26 }
pt3080PrecorrectorLinearMonitorAmplitudeRippleValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is amplitude ripple information valid"
::= { pt3080Precorrector 30 }
pt3080PrecorrectorLinearMonitorGroupDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group delay"
::= { pt3080Precorrector 27 }
pt3080PrecorrectorLinearMonitorGroupDelayValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is group delay information valid"
::= { pt3080Precorrector 31 }
pt3080PrecorrectorLinearMonitorDiscartedIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations discarded by the linear adaptive precorrector
due to noisy signal samples."
::= { pt3080Precorrector 47 }
pt3080PrecorrectorLinearMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations made by the linear adaptive precorrector."
::= { pt3080Precorrector 19 }
pt3080PrecorrectorLinearAdaptiveMode OBJECT-TYPE
SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the linear adaptive precorrector
<br/>(note: legacy term used for backward compatibility. IDLE
Equal to the mode named MONITORING in the WEB GUI )"
::= { pt3080Precorrector 1 }
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the amplitude ripple"
::= { pt3080Precorrector 42 }
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the amplitude
ripple"
::= { pt3080Precorrector 14 }
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable amplitude ripple as a trigger for the AUTORUN and RUNTOTARGET
modes"
::= { pt3080Precorrector 10 }
pt3080PrecorrectorLinearAdaptiveGroupDelayTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.1 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the group delay"
::= { pt3080Precorrector 43 }
pt3080PrecorrectorLinearAdaptiveGroupDelayTargetHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100000 )
UNITS "0.01 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the group delay"
::= { pt3080Precorrector 15 }
pt3080PrecorrectorLinearAdaptiveGroupDelayEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable group delay as a trigger for the AUTORUN and RUNTOTARGET
modes"
::= { pt3080Precorrector 11 }
pt3080PrecorrectorLinearAttenuation OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a attenuation level for the sense input"
::= { pt3080Precorrector 78 }
pt3080PrecorrectorNonlinearAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Non-Linear precorrection curve active in the system"
::= { pt3080Precorrector 80 }
pt3080PrecorrectorNonlinearMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the non-linear precorrector
<br/>(note: legacy term used for backward compatibility. MONITORING
Equal to the mode named BYPASS in the WEB GUI )"
::= { pt3080Precorrector 4 }
pt3080PrecorrectorNonlinearSenseEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By using this, it is possible to control wether to use the nonlinear
Sense Input or not."
::= { pt3080Precorrector 48 }
pt3080PrecorrectorNonlinearMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nonlinear Precor state"
::= { pt3080Precorrector 40 }
pt3080PrecorrectorNonlinearMonitorSenseLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level meassured at the Nonlinear sense input with offset defined
by attenuation"
::= { pt3080Precorrector 38 }
pt3080PrecorrectorNonlinearMonitorSenseValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Nonlinear sense input information valid"
::= { pt3080Precorrector 39 }
pt3080PrecorrectorNonlinearMonitorSenseBadCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bad/invalid sense counts, made by the nonlinear adaptive
precorrector."
::= { pt3080Precorrector 9 }
pt3080PrecorrectorNonlinearMonitorLowerShoulderLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lower shoulder level"
::= { pt3080Precorrector 28 }
pt3080PrecorrectorNonlinearMonitorLowerShoulderValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Lower shoulder information valid"
::= { pt3080Precorrector 32 }
pt3080PrecorrectorNonlinearMonitorUpperShoulderLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upper shoulder level"
::= { pt3080Precorrector 29 }
pt3080PrecorrectorNonlinearMonitorUpperShoulderValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Upper shoulder information valid"
::= { pt3080Precorrector 33 }
pt3080PrecorrectorNonlinearMonitorDiscartedIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations discarded by the non-linear adaptive precorrector
dur to noisy signal samples."
::= { pt3080Precorrector 49 }
pt3080PrecorrectorNonlinearMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations made by the nonlinear adaptive precorrector."
::= { pt3080Precorrector 35 }
pt3080PrecorrectorNonlinearMonitorMer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MER"
::= { pt3080Precorrector 50 }
pt3080PrecorrectorNonlinearMonitorMerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is MER information valid"
::= { pt3080Precorrector 51 }
pt3080PrecorrectorNonlinearMonitorPapr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PAPR level"
::= { pt3080Precorrector 52 }
pt3080PrecorrectorNonlinearMonitorPaprValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Papr information valid"
::= { pt3080Precorrector 53 }
pt3080PrecorrectorNonlinearAttenuation OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a attenuation level for the sense input"
::= { pt3080Precorrector 77 }
pt3080PrecorrectorNonlinearAdaptiveMode OBJECT-TYPE
SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the non-linear adaptive
precorrector <br/>(note: legacy term used for backward compatibility.
IDLE Equal to the mode named MONITORING in the WEB GUI )"
::= { pt3080Precorrector 3 }
pt3080PrecorrectorNonlinearAdaptiveAveraging OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Choose wether or not to use averaging calulations"
::= { pt3080Precorrector 54 }
pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable the modulator's output PAPR limiter function"
::= { pt3080Precorrector 55 }
pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprLimit OBJECT-TYPE
SYNTAX Integer32 ( 20 .. 180 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum RF PAPR Limitation"
::= { pt3080Precorrector 56 }
pt3080PrecorrectorNonlinearAdaptiveMerTarget OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 800 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a target level for the MER"
::= { pt3080Precorrector 57 }
pt3080PrecorrectorNonlinearAdaptiveMerTargetHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a target MER hysteresis"
::= { pt3080Precorrector 58 }
pt3080PrecorrectorNonlinearAdaptiveMerEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable MER as a trigger for the AUTORUN and RUNTOTARGET modes"
::= { pt3080Precorrector 59 }
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( -800 .. 0 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the lower shoulder"
::= { pt3080Precorrector 44 }
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the lower shoulder"
::= { pt3080Precorrector 16 }
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable shoulder level (lower) as a trigger for the AUTORUN and
RUNTOTARGET modes"
::= { pt3080Precorrector 12 }
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( -800 .. 0 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the upper shoulder"
::= { pt3080Precorrector 45 }
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetHysteresis OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the upper shoulder"
::= { pt3080Precorrector 17 }
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable shoulder level (upper) as a trigger for the AUTORUN and
RUNTOTARGET modes"
::= { pt3080Precorrector 13 }
pt3080PrecorrectorPaprClipping OBJECT-TYPE
SYNTAX Integer32 ( 200 .. 1200 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set the built-in peak clipper function. The value 'max' corresponds
to an unclipped COFDM signal (12dB peak to average ratio).
The value 'min' correspondsto COFDM signal where all peaks >2dB
above average power are clipped. When feeding the output from
the modulator through an amplifier the best overall performance
result is normally obtained if the clipper value used by modulator
clips the signal just a fraction before the amplifier would
clip the signal."
::= { pt3080Precorrector 60 }
pt3080PrecorrectorPaprShaping OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the output peak shaping filter hardness. The value 'min'
correspond to traditional 'hard-clipping' where the clipper
noise is equally distributed below, inside and above the COFDM
spectrum (clipper noise clearly visible in the form of noise
above and below the spectrum. The value 'max' corresponds to
maximum soft clipping where the clipper noise in the sidebands
(above and below the COFDM spectrum) is subjected to maximum
suppression while still maintaining the exact clipper value
(peak-to-average-ration). The suppression of the sideband noise
is obtained as a tradeoff against the in band performance.
The clip filter setting is typically selected as a compromise
between spectrum shoulder performance and in-band signal performance
(MER)."
::= { pt3080Precorrector 61 }
pt3080PrecorrectorClipperMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection between no, static (manual) and adaptive clipper function"
::= { pt3080Precorrector 74 }
pt3080PrecorrectorClipperAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clipper shaped by the OptiClipper algorithm"
::= { pt3080Precorrector 75 }
pt3080PrecorrectorClipperEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clipper enable"
::= { pt3080Precorrector 76 }
pt3080PrecorrectorClipperAdaptiveMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), continuous(1), single(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection of the operational mode for the adaptive clipper function"
::= { pt3080Precorrector 63 }
pt3080PrecorrectorClipperAdaptiveShaping OBJECT-TYPE
SYNTAX Integer32 ( 99 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Depricated Therefore min and max value are set to 100% Set the
peak shaping filter hardness. The value 'min' correspond to
traditional 'hard-clipping' where the clipper noise is equally
distributed below, inside and above the COFDM spectrum (clipper
noise clearly visible in the form of noise above and below
the spectrum. The value 'max' corresponds to maximum soft clipping
where the clipper noise in the sidebands (above and below the
COFDM spectrum) is subjected to maximum suppression while still
maintaining the exact clipper value (peak-to-average-ration).
The suppression of the sideband noise is obtained as a tradeoff
against the in band performance. The clip filter setting is
typically selected as a compromise between spectrum shoulder
performance and in-band signal performance (MER)."
::= { pt3080Precorrector 81 }
pt3080PrecorrectorClipperMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OptiClipper state"
::= { pt3080Precorrector 64 }
pt3080PrecorrectorClipperMonitorShoulderLevelLower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lower shoulder level"
::= { pt3080Precorrector 65 }
pt3080PrecorrectorClipperMonitorShoulderLevelLowerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Lower shoulder information valid"
::= { pt3080Precorrector 66 }
pt3080PrecorrectorClipperMonitorShoulderLevelUpper OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upper shoulder level"
::= { pt3080Precorrector 67 }
pt3080PrecorrectorClipperMonitorShoulderLevelUpperValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Upper shoulder information valid"
::= { pt3080Precorrector 68 }
pt3080PrecorrectorClipperMonitorMer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MER level"
::= { pt3080Precorrector 69 }
pt3080PrecorrectorClipperMonitorMerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is MER information valid"
::= { pt3080Precorrector 70 }
pt3080PrecorrectorClipperMonitorPapr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PAPR level"
::= { pt3080Precorrector 71 }
pt3080PrecorrectorClipperMonitorPaprValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Papr information valid"
::= { pt3080Precorrector 72 }
pt3080PrecorrectorClipperMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Iterations performed by the OptiClipper algorithm"
::= { pt3080Precorrector 73 }
pt3080PrecorrectorLastTurnAroundTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorLastTurnAroundTime "
::= { pt3080Precorrector 6 }
pt3080PrecorrectorSecondsSinceLastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorSecondsSinceLastUpdate "
::= { pt3080Precorrector 7 }
pt3080PrecorrectorLinCleanrun OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorLinCleanrun "
::= { pt3080Precorrector 18 }
pt3080PrecorrectorNlinCleanrun OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorNlinCleanrun "
::= { pt3080Precorrector 34 }
pt3080PrecorrectorLinearLoadNeutral OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearLoadNeutral "
::= { pt3080Precorrector 20 }
pt3080PrecorrectorLinearLoadFactory OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearLoadFactory "
::= { pt3080Precorrector 21 }
pt3080PrecorrectorLinearUpdateFactoryCurve OBJECT-TYPE
SYNTAX INTEGER { noop(0), update(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearUpdateFactoryCurve "
::= { pt3080Precorrector 25 }
pt3080PrecorrectorNonlinearLoadNeutral OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearLoadNeutral "
::= { pt3080Precorrector 36 }
pt3080PrecorrectorNonlinearLoadFactory OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearLoadFactory "
::= { pt3080Precorrector 37 }
pt3080PrecorrectorNonlinearUpdateFactoryCurve OBJECT-TYPE
SYNTAX INTEGER { noop(0), update(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearUpdateFactoryCurve "
::= { pt3080Precorrector 41 }
--
-- pt3080 Backplane sub-tree
--
pt3080BackplanePolarityHardMute OBJECT-TYPE
SYNTAX INTEGER { activelow(0), activehigh(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the polarity of the Hard Mute input pin on the PTT2 backplane."
::= { pt3080Backplane 1 }
pt3080BackplanePolarityRFFail OBJECT-TYPE
SYNTAX INTEGER { activelow(0), activehigh(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the polarity of the RF Fail output pin on the PTT2 backplane."
::= { pt3080Backplane 2 }
--
-- pt3080 Notifications sub-tree
--
pt3080Notif OBJECT IDENTIFIER ::= { pt3080Notifs 0 }
pt3080NotifMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current alarm notification message"
::= { pt3080Notifs 1 }
pt3080NotifState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current alarm notification state"
::= { pt3080Notifs 2 }
pt3080NotifLocalTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The time the current alarm notification state changed"
::= { pt3080Notifs 3 }
-- SNMPv2 compliance nonsense --
pt3080Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems supporting
the this MIB."
MODULE -- this module
MANDATORY-GROUPS {
pt3080SystemGroup, pt3080InputGroup, pt3080OutputGroup,
pt3080MonitorGroup,
pt3080TestGroup, pt3080AlarmGroup, pt3080PresetGroup,
pt3080EventlogGroup, pt3080CommsGroup, pt3080PrecorrectorGroup
}
GROUP pt3080ModeGroup
DESCRIPTION
"This group is optional."
GROUP pt3080GpsGroup
DESCRIPTION
"This group is optional."
GROUP pt3080ChannelFilterGroup
DESCRIPTION
"This group is optional."
GROUP pt3080TSoIPGroup
DESCRIPTION
"This group is optional."
GROUP pt3080DemodulatorGroup
DESCRIPTION
"This group is optional."
GROUP pt3080ReceptionGroup
DESCRIPTION
"This group is optional."
GROUP pt3080ASIGroup
DESCRIPTION
"This group is optional."
::= { pt3080Compliances 1 }
pt3080Groups OBJECT IDENTIFIER ::= { pt3080Conformance 2 }
pt3080SystemGroup OBJECT-GROUP
OBJECTS {
pt3080SystemInstrumentFW1Rev,
pt3080SystemInstrumentFW1RevBL,
pt3080SystemInstrumentFW2Rev,
pt3080SystemInstrumentFW2RevBL,
pt3080SystemInstrumentFW3Rev,
pt3080SystemInstrumentFW4Rev,
pt3080SystemInstrumentPCBRev,
pt3080SystemInstrumentCalibrationRev,
pt3080SystemInstrumentCalibrationDate,
pt3080SystemReboot,
pt3080SystemRebootDefaultConfig,
pt3080SystemDateTime,
pt3080SystemImage0Version,
pt3080SystemImage0InstalledDate,
pt3080SystemImage1version,
pt3080SystemImage1InstalledDate,
pt3080SystemScheduledActionRecurrence,
pt3080SystemScheduledActionHour,
pt3080SystemScheduledActionMinute,
pt3080SystemScheduledActionWeekday,
pt3080SystemScheduledActionMonthDay,
pt3080SystemScheduledActionDate,
pt3080SystemScheduledActionRandomDelay,
pt3080SystemScheduledActionAction,
pt3080SystemScheduledActionRepeaterMode,
pt3080SystemScheduledActionPresetNo,
pt3080SystemScheduledActionRebootImage,
pt3080SystemScheduledActionRebootSystemType,
pt3080SystemScheduledActionMute,
pt3080SystemScheduledActionSWUpgradeProtocol,
pt3080SystemScheduledActionSWUpgradeUsername,
pt3080SystemScheduledActionSWUpgradePassword,
pt3080SystemScheduledActionSWUpgradeImageServer,
pt3080SystemScheduledActionSWUpgradeImagePath,
pt3080SystemServiceLED
,
pt3080SystemLanguage
,
pt3080SystemType,
pt3080SystemModulationStandard,
pt3080SystemCurrentImage,
pt3080SystemInstrumentKU,
pt3080SystemInstrumentType,
pt3080SystemInstrumentOptions,
pt3080SystemDateTimeSync,
pt3080SystemDateTimeSyncActual,
pt3080SystemTimezone,
pt3080SystemInstrumentSWRev,
pt3080SystemInstrumentBootLoaderRev,
pt3080SystemInstrumentKernelRev,
pt3080SystemOperationOnTime,
pt3080SystemOperationOnAirTime,
pt3080SystemOperationNumberOfBoots,
pt3080SystemBackplaneid,
pt3080SystemBackplaneIdRaw,
pt3080SystemBackplaneIdPcb,
pt3080SystemBackplaneIdCableOptions,
pt3080SystemBackplaneIdMAnuf,
pt3080SystemBackplaneCalibrationDate,
pt3080SystemBackplaneCalibrationSw,
pt3080SystemBackplaneIdPartlist
}
STATUS current
DESCRIPTION
"System group"
::= { pt3080Groups 1}
pt3080ModeGroup OBJECT-GROUP
OBJECTS {
pt3080ModeListenBroadcast
,
pt3080ModeNetwork,
pt3080ModeHierarchy,
pt3080Modeifft,
pt3080ModeCodeRateHighPrio,
pt3080ModeCodeRateLowPrio,
pt3080ModeConstellation,
pt3080ModeGuardInterval,
pt3080ModeCellID,
pt3080ModeEnableCellID,
pt3080ModeDeepInterleaver,
pt3080ModeEnableDVBH,
pt3080ModeMpeFecLowPrio,
pt3080ModeMpeFecHighPrio,
pt3080ModeTimeSlicingLowPrio,
pt3080ModeTimeSlicingHighPrio,
pt3080ModeSfnDelayOffset,
pt3080ModeTxIdent,
pt3080ModeMipControl,
pt3080ModeNetworkDelayHP,
pt3080ModeNetworkDelayMinHP,
pt3080ModeNetworkDelayMaxHP,
pt3080ModeMaxNetworkDelayHP,
pt3080ModeNetworkDelayMarginHP,
pt3080ModeNetworkDelayLP,
pt3080ModeNetworkDelayMinLP,
pt3080ModeNetworkDelayMaxLP,
pt3080ModeMaxNetworkDelayLP,
pt3080ModeNetworkDelayMarginLP,
pt3080ModeNetworkDelayReset,
pt3080ModeDefaultMIPOutputPower,
pt3080ModeDefaultMIPOutputTimeOffset,
pt3080ModeDefaultMIPOutputCellID,
pt3080ModeDefaultMIPOutputFreqOffset,
pt3080ModeMIPMaxSFNDelay,
pt3080ModeMipControlOutputPower,
pt3080ModeMipControlOutputTimeOffset,
pt3080ModeMipControlOutputCellId,
pt3080ModeMipControlOutputFreqOffset,
pt3080ModeMfnKeepNullPackets
}
STATUS current
DESCRIPTION
"DVB-T Mode group"
::= { pt3080Groups 2}
pt3080InputGroup OBJECT-GROUP
OBJECTS {
pt3080InputASITSPrimarySource,
pt3080InputASITSSecondarySource,
pt3080InputASIAutoRoutingPolicy,
pt3080InputTSPrimaryMaxPATDelay,
pt3080InputTSPrimaryMaxPATDelayEnable,
pt3080InputTSPrimaryExpectedTSID,
pt3080InputTSPrimaryExpectedTSIDEnable,
pt3080InputTSPrimaryExpectedNWID,
pt3080InputTSPrimaryExpectedNWIDEnable,
pt3080InputTSPrimaryMaxStuffingrate,
pt3080InputTSPrimaryMaxStuffingrateEnable,
pt3080InputTSPrimaryMinDelaymargin,
pt3080InputTSPrimaryMinDelaymarginEnable,
pt3080InputTSPrimaryMaxMissingmip,
pt3080InputTSPrimaryMaxMissingmipEnable,
pt3080InputTSSecondaryMaxPATDelay,
pt3080InputTSSecondaryMaxPATDelayEnable,
pt3080InputTSSecondaryExpectedTSID,
pt3080InputTSSecondaryExpectedTSIDEnable,
pt3080InputTSSecondaryExpectedNWID,
pt3080InputTSSecondaryExpectedNWIDEnable,
pt3080InputTSSecondaryMaxStuffingrate,
pt3080InputTSSecondaryMaxStuffingrateEnable,
pt3080InputTSSecondaryMinDelaymargin,
pt3080InputTSSecondaryMinDelaymarginEnable,
pt3080InputTSSecondaryMaxMissingmip,
pt3080InputTSSecondaryMaxMissingmipEnable
,
pt3080InputTSPrimaryMaxStsJitter,
pt3080InputTSSecondaryMaxStsJitter,
pt3080InputTSPrimaryStatus,
pt3080InputTSSecondaryStatus,
pt3080InputTSHp,
pt3080InputTSLp,
pt3080InputEffectiveAutoroutingPolicy,
pt3080InputTSHpBitrate,
pt3080InputTSLpBitrate,
pt3080InputTSHpPacketsBuffered,
pt3080InputTSHpPacketSize,
pt3080InputTSHpStuffingrate,
pt3080InputTSHpTSID,
pt3080InputTSLpPacketsBuffered,
pt3080InputTSLpPacketSize,
pt3080InputTSLpStuffingrate,
pt3080InputTSLpTSID,
pt3080InputTSHpNWID,
pt3080InputTSLpNWID,
pt3080InputTSPrimaryStsJitter,
pt3080InputTSPrimaryStsJitterMax,
pt3080InputTSPrimaryStsJitterMin,
pt3080InputTSPrimaryStsJitterReset,
pt3080InputTSSecondaryStsJitter,
pt3080InputTSSecondaryStsJitterMax,
pt3080InputTSSecondaryStsJitterMin,
pt3080InputTSSecondaryStsJitterReset,
pt3080InputRefDevType,
pt3080InputRefCalDate,
pt3080InputRefCalVer
,
pt3080InputRefDirection
,
pt3080InputRefSource,
pt3080InputRefStatus,
pt3080InputRef10MhzImpedance,
pt3080InputRef10MhzHoldoverDelay,
pt3080InputRef10MhzHoldoverForever,
pt3080InputRef1PPSImpedance,
pt3080InputRef1PPSHoldoverDelay,
pt3080InputRef1PPSHoldoverForever,
pt3080InputRef1PPSTrigSlope,
pt3080InputRef1PPSTrigLevel,
pt3080InputASIAutoRoutingDelayHp2Lp,
pt3080InputASIAutoRoutingDelayLp2Hp,
pt3080InputASIHoldoverTimeout
}
STATUS current
DESCRIPTION
"Input group"
::= { pt3080Groups 3}
pt3080OutputGroup OBJECT-GROUP
OBJECTS {
pt3080OutputIfEnable,
pt3080OutputIfFrequency,
pt3080OutputIfPolarity,
pt3080OutputIfLevel,
pt3080OutputMode,
pt3080OutputEffectiveLevel,
pt3080OutputActualLevel,
pt3080OutputPolarity,
pt3080OutputRfFrequency,
pt3080OutputRfFrequencyOffset,
pt3080OutputRfLevel,
pt3080OutputRfCableMode,
pt3080OutputRfCableConstantLevelOffset,
pt3080OutputRfCableFrequencyLevelOffset0,
pt3080OutputRfCableFrequencyLevelOffset1,
pt3080OutputRfCableFrequencyLevelOffset2,
pt3080OutputRfCableFrequencyLevelOffset3,
pt3080OutputRfCableFrequencyLevelOffset4,
pt3080OutputRfCableFrequencyLevelOffset5,
pt3080OutputRfDetectedActualLevel,
pt3080OutputRfDetectedLowerLevelLimit,
pt3080OutputRfDetectedLowerLevelcontrol,
pt3080OutputRfDetectedHigherLevelLimit,
pt3080OutputRfDetectedHigherLevelcontrol,
pt3080OutputRfAlcControl,
pt3080OutputRfAlcSense,
pt3080OutputRfAlcSetpointPort1,
pt3080OutputRfAlcSetpointPort2,
pt3080OutputRfAlcStatus,
pt3080OutputRfAlcStatusInformation
,pt3080OutputBandwidth,
pt3080OutputChannel,
pt3080OutputSynchronized,
pt3080OutputMute,
pt3080OutputPowerLevel
}
STATUS current
DESCRIPTION
"Output group"
::= { pt3080Groups 4}
pt3080GpsGroup OBJECT-GROUP
OBJECTS {
pt3080GpsBias,
pt3080GpsbiasVoltage
,
pt3080GpsCableDelay
,
pt3080GpsHoldoverForever,
pt3080GpsHoldoverTime,
pt3080GpsSatelliteSystemGPS,
pt3080GpsSatelliteSystemGLONASS,
pt3080GpsSatelliteSystemGALILEO,
pt3080GpsSatelliteSystemCOMPASS,
pt3080GpsVersion,
pt3080Gps1PPSStatus,
pt3080GpsState,
pt3080GpsVisibleSatellitesSnr,
pt3080GpsVisibleSatellites,
pt3080GpsTrackedSatellites,
pt3080GpsLongtitude,
pt3080GpsLatitude,
pt3080GpsAltitude
}
STATUS current
DESCRIPTION
"GPS group"
::= { pt3080Groups 7}
pt3080ChannelFilterGroup OBJECT-GROUP
OBJECTS {
pt3080ChannelFiltersSelect
}
STATUS current
DESCRIPTION
"Channel Filter group"
::= { pt3080Groups 8}
pt3080TSoIPGroup OBJECT-GROUP
OBJECTS {
pt3080TSoIPRx1ReceiverEnable,
pt3080TSoIPRx2ReceiverEnable,
pt3080TSoIPRx1LanSelect,
pt3080TSoIPRx2LanSelect,
pt3080TSoIPRx1Multicast,
pt3080TSoIPRx2Multicast,
pt3080TSoIPRx1Protocol,
pt3080TSoIPRx2Protocol,
pt3080TSoIPRx1Portnumber,
pt3080TSoIPRx2Portnumber,
pt3080TSoIPRx1PacketErrorRatioLimit,
pt3080TSoIPRx2PacketErrorRatioLimit,
pt3080TSoIPRx1MinumimLatency,
pt3080TSoIPRx2MinumimLatency,
pt3080TSoIPRx1SyncTimeout,
pt3080TSoIPRx2SyncTimeout,
pt3080TSoIPRx1Status,
pt3080TSoIPRx2Status,
pt3080TSoIPRx1CurrentIPAddress,
pt3080TSoIPRx2CurrentIPAddress,
pt3080TSoIPRx1IpBitrate,
pt3080TSoIPRx2IpBitrate,
pt3080TSoIPRx1PacketErrorRatio,
pt3080TSoIPRx2PacketErrorRatio,
pt3080TSoIPRx1SequenceErrors,
pt3080TSoIPRx2SequenceErrors,
pt3080TSoIPRx1LostIPFrames,
pt3080TSoIPRx2LostIPFrames,
pt3080TSoIPRx1CorrectedIPFrames,
pt3080TSoIPRx2CorrectedIPFrames,
pt3080TSoIPRx1OverrunIPFrames,
pt3080TSoIPRx2OverrunIPFrames,
pt3080TSoIPRx1PacketsPerFrame,
pt3080TSoIPRx2PacketsPerFrame,
pt3080TSoIPRx1TSPacketSize,
pt3080TSoIPRx2TSPacketSize,
pt3080TSoIPRx1FecColumn,
pt3080TSoIPRx2FecColumn,
pt3080TSoIPRx1FecRow,
pt3080TSoIPRx2FecRow,
pt3080TSoIPRx1QueueSize,
pt3080TSoIPRx2QueueSize,
pt3080TSoIPRx1CurrentLatency,
pt3080TSoIPRx2CurrentLatency
}
STATUS current
DESCRIPTION
"TSoIP group"
::= { pt3080Groups 10}
pt3080MonitorGroup OBJECT-GROUP
OBJECTS {
pt3080MonitorSource,
pt3080MonitorTSoIPEnable,
pt3080MonitorTSoIPSource,
pt3080MonitorTSoIPMulticastLanSelect,
pt3080MonitorTSoIPDestIPAddress,
pt3080MonitorTSoIPDestPort,
pt3080MonitorTSoIPProtocol,
pt3080MonitorTSoIPEnableFec,
pt3080MonitorTSoIPFecColumn,
pt3080MonitorTSoIPFecRow,
pt3080MonitorTSoIPFecSkew,
pt3080MonitorTSoIPKeepNullPackets,
pt3080MonitorTSoIPPacketsPerFrame,
pt3080MonitorTSoIPUDPChecksum,
pt3080MonitorTSoIPDSCP,
pt3080MonitorTSoIPTTL,
pt3080MonitorTSoIPGenerateError,
pt3080MonitorTSoIPIpBitrate,
pt3080MonitorTSoIPTSSize,
pt3080MonitorTSoIPLostIPFrames
}
STATUS current
DESCRIPTION
"Signal monitor group"
::= { pt3080Groups 12}
pt3080TestGroup OBJECT-GROUP
OBJECTS {
pt3080TestEnable,
pt3080TestEnableReconnect,
pt3080TestScarrierLevel,
pt3080TestscarrierFrequencyOffset
}
STATUS current
DESCRIPTION
"Test Signal group"
::= { pt3080Groups 13}
pt3080AlarmGroup OBJECT-GROUP
OBJECTS {
pt3080GroupAlarmDescription,
pt3080GroupAlarmState,
pt3080GroupAlarmActionEventlog,
pt3080GroupAlarmActionRelay1,
pt3080GroupAlarmActionRelay2,
pt3080GroupAlarmActionTrap,
pt3080GroupAlarmActionEmail,
pt3080GroupAlarmActionAlarmLED,
pt3080GroupAlarmActionForceMode,
pt3080ASITSPrimaryAlarmDescription,
pt3080ASITSPrimaryAlarmState,
pt3080ASITSPrimaryAlarmActionEventlog,
pt3080ASITSPrimaryAlarmActionRelay1,
pt3080ASITSPrimaryAlarmActionRelay2,
pt3080ASITSPrimaryAlarmActionTrap,
pt3080ASITSPrimaryAlarmActionEmail,
pt3080ASITSPrimaryAlarmActionAlarmLED,
pt3080ASITSPrimaryAlarmActionForceMode,
pt3080ASITSSecondaryAlarmDescription,
pt3080ASITSSecondaryAlarmState,
pt3080ASITSSecondaryAlarmActionEventlog,
pt3080ASITSSecondaryAlarmActionRelay1,
pt3080ASITSSecondaryAlarmActionRelay2,
pt3080ASITSSecondaryAlarmActionTrap,
pt3080ASITSSecondaryAlarmActionEmail,
pt3080ASITSSecondaryAlarmActionAlarmLED,
pt3080ASITSSecondaryAlarmActionForceMode,
pt3080SFNAlarmDescription,
pt3080SFNAlarmState,
pt3080SFNAlarmActionEventlog,
pt3080SFNAlarmActionRelay1,
pt3080SFNAlarmActionRelay2,
pt3080SFNAlarmActionTrap,
pt3080SFNAlarmActionEmail,
pt3080SFNAlarmActionAlarmLED,
pt3080SFNAlarmActionForceMode,
pt3080TSoIPAlarmDescription,
pt3080TSoIPAlarmState,
pt3080TSoIPAlarmActionEventlog,
pt3080TSoIPAlarmActionRelay1,
pt3080TSoIPAlarmActionRelay2,
pt3080TSoIPAlarmActionTrap,
pt3080TSoIPAlarmActionEmail,
pt3080TSoIPAlarmActionAlarmLED,
pt3080TSoIPAlarmActionForceMode,
pt3080DemodulatorAlarmDescription,
pt3080DemodulatorAlarmState,
pt3080DemodulatorAlarmActionEventlog,
pt3080DemodulatorAlarmActionRelay1,
pt3080DemodulatorAlarmActionRelay2,
pt3080DemodulatorAlarmActionTrap,
pt3080DemodulatorAlarmActionEmail,
pt3080DemodulatorAlarmActionAlarmLED,
pt3080DemodulatorAlarmActionForceMode,
pt3080ReferenceAlarmDescription,
pt3080ReferenceAlarmState,
pt3080ReferenceAlarmActionEventlog,
pt3080ReferenceAlarmActionRelay1,
pt3080ReferenceAlarmActionRelay2,
pt3080ReferenceAlarmActionTrap,
pt3080ReferenceAlarmActionEmail,
pt3080ReferenceAlarmActionAlarmLED,
pt3080ReferenceAlarmActionForceMode,
pt3080RFAlarmDescription,
pt3080RFAlarmState,
pt3080RFAlarmActionEventlog,
pt3080RFAlarmActionRelay1,
pt3080RFAlarmActionRelay2,
pt3080RFAlarmActionTrap,
pt3080RFAlarmActionEmail,
pt3080RFAlarmActionAlarmLED,
pt3080RFAlarmActionForceMode,
pt3080GPSAlarmDescription,
pt3080GPSAlarmState,
pt3080GPSAlarmActionEventlog,
pt3080GPSAlarmActionRelay1,
pt3080GPSAlarmActionRelay2,
pt3080GPSAlarmActionTrap,
pt3080GPSAlarmActionEmail,
pt3080GPSAlarmActionAlarmLED,
pt3080GPSAlarmActionForceMode,
pt3080ExternalAlarmDescription,
pt3080ExternalAlarmState,
pt3080ExternalAlarmActionEventlog,
pt3080ExternalAlarmActionRelay1,
pt3080ExternalAlarmActionRelay2,
pt3080ExternalAlarmActionTrap,
pt3080ExternalAlarmActionEmail,
pt3080ExternalAlarmActionAlarmLED,
pt3080ExternalAlarmActionForceMode,
pt3080HWMonitorAlarmDescription,
pt3080HWMonitorAlarmState,
pt3080HWMonitorAlarmActionEventlog,
pt3080HWMonitorAlarmActionRelay1,
pt3080HWMonitorAlarmActionRelay2,
pt3080HWMonitorAlarmActionTrap,
pt3080HWMonitorAlarmActionEmail,
pt3080HWMonitorAlarmActionAlarmLED,
pt3080HWMonitorAlarmActionForceMode,
pt3080CommsAlarmDescription,
pt3080CommsAlarmState,
pt3080CommsAlarmActionEventlog,
pt3080CommsAlarmActionRelay1,
pt3080CommsAlarmActionRelay2,
pt3080CommsAlarmActionTrap,
pt3080CommsAlarmActionEmail,
pt3080CommsAlarmActionAlarmLED,
pt3080CommsAlarmActionForceMode,
pt3080InternalAlarmDescription,
pt3080InternalAlarmState,
pt3080InternalAlarmActionEventlog,
pt3080InternalAlarmActionRelay1,
pt3080InternalAlarmActionRelay2,
pt3080InternalAlarmActionTrap,
pt3080InternalAlarmActionEmail,
pt3080InternalAlarmActionAlarmLED,
pt3080InternalAlarmActionForceMode,
pt3080ASIAlarmDescription,
pt3080ASIAlarmState,
pt3080ASIAlarmActionEventlog,
pt3080ASIAlarmActionRelay1,
pt3080ASIAlarmActionRelay2,
pt3080ASIAlarmActionTrap,
pt3080ASIAlarmActionEmail,
pt3080ASIAlarmActionAlarmLED,
pt3080ASIAlarmActionForceMode
}
STATUS current
DESCRIPTION
"Alarm group"
::= { pt3080Groups 14}
pt3080PresetGroup OBJECT-GROUP
OBJECTS {
pt3080PresetName,
pt3080PresetRecall,
pt3080PresetStore
}
STATUS current
DESCRIPTION
"Preset group"
::= { pt3080Groups 15}
pt3080EventlogGroup OBJECT-GROUP
OBJECTS {
pt3080EventlogID,
pt3080EventlogTimestamp,
pt3080EventlogText,
pt3080EventlogClear,
pt3080EventlogEnable,
pt3080EventlogMode
}
STATUS current
DESCRIPTION
"Eventlog group"
::= { pt3080Groups 16}
pt3080CommsGroup OBJECT-GROUP
OBJECTS {
pt3080CommsAccessPasswordObserver,
pt3080CommsAccessPasswordOperator,
pt3080CommsAccessPasswordAdministrator,
pt3080CommsStaticRouteType,
pt3080CommsStaticRoutePrefix,
pt3080CommsStaticRoutePrefixSize,
pt3080CommsStaticRouteTarget,
pt3080CommsStaticRoutePhysicalInterface,
pt3080CommsAlarmEmailReceiver,
pt3080CommsSeparatedSwitchPorts,
pt3080CommsBroadcastStormProtection,
pt3080CommsLocalPhysicalInterface,
pt3080CommsLocalDhcpMode,
pt3080CommsLocalStaticIpAddr,
pt3080CommsLocalStaticNetmask,
pt3080CommsLocalIpMulticastAddr,
pt3080CommsLocalIpMulticastSourceFilterMode,
pt3080CommsLocalIpMulticastSourceFilterAddress1,
pt3080CommsLocalIpMulticastSourceFilterAddress2,
pt3080CommsLocalIpMulticastSourceFilterAddress3,
pt3080CommsLocalIpMulticastSourceFilterAddress4,
pt3080CommsLocalIpMulticastSourceFilterAddress5,
pt3080CommsLocalIpMulticastSourceFilterAddress6,
pt3080CommsLocalVlanEnable,
pt3080CommsLocalVlanId,
pt3080CommsLocalServiceSNMP,
pt3080CommsLocalServiceSCPI,
pt3080CommsLocalServiceTSoIP,
pt3080CommsLocalServiceRIP,
pt3080CommsLocalCurrentIpAddr,
pt3080CommsLocalCurrentNetmask,
pt3080CommsRemoteEnable,
pt3080CommsRemotePhysicalInterface,
pt3080CommsRemoteDhcpMode,
pt3080CommsRemoteStaticIpAddr,
pt3080CommsRemoteStaticNetmask,
pt3080CommsRemoteIpMulticastAddr,
pt3080CommsRemoteIpMulticastSourceFilterMode,
pt3080CommsRemoteIpMulticastSourceFilterAddress1,
pt3080CommsRemoteIpMulticastSourceFilterAddress2,
pt3080CommsRemoteIpMulticastSourceFilterAddress3,
pt3080CommsRemoteIpMulticastSourceFilterAddress4,
pt3080CommsRemoteIpMulticastSourceFilterAddress5,
pt3080CommsRemoteIpMulticastSourceFilterAddress6,
pt3080CommsRemoteVlanEnable,
pt3080CommsRemoteVlanId,
pt3080CommsRemoteServiceSNMP,
pt3080CommsRemoteServiceSCPI,
pt3080CommsRemoteServiceTSoIP,
pt3080CommsRemoteServiceWeb,
pt3080CommsRemoteServiceRIP,
pt3080CommsRemoteCurrentIpAddr,
pt3080CommsRemoteCurrentNetmask,
pt3080CommsGbeAdminEnable,
pt3080CommsGbeAdminPhysicalInterface,
pt3080CommsGbeAdminDhcpMode,
pt3080CommsGbeAdminStaticIpAddr,
pt3080CommsGbeAdminStaticNetmask,
pt3080CommsGbeAdminIpMulticastAddr,
pt3080CommsGbeAdminIpMulticastSourceFilterMode,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress1,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress2,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress3,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress4,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress5,
pt3080CommsGbeAdminIpMulticastSourceFilterAddress6,
pt3080CommsGbeAdminVlanEnable,
pt3080CommsGbeAdminVlanId,
pt3080CommsGbeAdminServiceSNMP,
pt3080CommsGbeAdminServiceSCPI,
pt3080CommsGbeAdminServiceTSoIP,
pt3080CommsGbeAdminServiceWeb,
pt3080CommsGbeAdminServiceRIP,
pt3080CommsGbeAdminCurrentIpAddr,
pt3080CommsGbeAdminCurrentNetmask,
pt3080CommsBackupEnable,
pt3080CommsBackupPhysicalInterface,
pt3080CommsBackupDhcpMode,
pt3080CommsBackupStaticIpAddr,
pt3080CommsBackupStaticNetmask,
pt3080CommsBackupIpMulticastAddr,
pt3080CommsBackupIpMulticastSourceFilterMode,
pt3080CommsBackupIpMulticastSourceFilterAddress1,
pt3080CommsBackupIpMulticastSourceFilterAddress2,
pt3080CommsBackupIpMulticastSourceFilterAddress3,
pt3080CommsBackupIpMulticastSourceFilterAddress4,
pt3080CommsBackupIpMulticastSourceFilterAddress5,
pt3080CommsBackupIpMulticastSourceFilterAddress6,
pt3080CommsBackupVlanEnable,
pt3080CommsBackupVlanId,
pt3080CommsBackupServiceSNMP,
pt3080CommsBackupServiceSCPI,
pt3080CommsBackupServiceTSoIP,
pt3080CommsBackupServiceWeb,
pt3080CommsBackupServiceRIP,
pt3080CommsBackupCurrentIpAddr,
pt3080CommsBackupCurrentNetmask,
pt3080CommsPortEnable,
pt3080CommsPortPhysicalInterface,
pt3080CommsPortDhcpMode,
pt3080CommsPortStaticIpAddr,
pt3080CommsPortStaticNetmask,
pt3080CommsPortIpMulticastAddr,
pt3080CommsPortIpMulticastSourceFilterMode,
pt3080CommsPortIpMulticastSourceFilterAddress1,
pt3080CommsPortIpMulticastSourceFilterAddress2,
pt3080CommsPortIpMulticastSourceFilterAddress3,
pt3080CommsPortIpMulticastSourceFilterAddress4,
pt3080CommsPortIpMulticastSourceFilterAddress5,
pt3080CommsPortIpMulticastSourceFilterAddress6,
pt3080CommsPortVlanEnable,
pt3080CommsPortVlanId,
pt3080CommsPortServiceSNMP,
pt3080CommsPortServiceSCPI,
pt3080CommsPortServiceTSoIP,
pt3080CommsPortServiceWeb,
pt3080CommsPortServiceRIP,
pt3080CommsPortCurrentIpAddr,
pt3080CommsPortCurrentNetmask,
pt3080CommsSNMPServicePort,
pt3080CommsSNMPReadOnlyCommunity,
pt3080CommsSNMPReadWriteCommunity,
pt3080CommsSNMPTrapCommunity,
pt3080CommsSNMPTrapDestination,
pt3080CommsSNMPTrapDestination2,
pt3080CommsSNMPTrapDestination3,
pt3080CommsSNMPTrapDestination4,
pt3080CommsSNMPTrapDestination5,
pt3080CommsSNMPTrapDestinationPort,
pt3080CommsSNMPTrapDestinationPort2,
pt3080CommsSNMPTrapDestinationPort3,
pt3080CommsSNMPTrapDestinationPort4,
pt3080CommsSNMPTrapDestinationPort5,
pt3080CommsStaticGateway,
pt3080CommsCurrentGateway,
pt3080CommsStaticHostname,
pt3080CommsCurrentHostname,
pt3080CommsStaticDNSDomain,
pt3080CommsCurrentDNSDomain,
pt3080CommsStaticDNS1ServerAddress,
pt3080CommsStaticDNS2ServerAddress,
pt3080CommsStaticDNS3ServerAddress,
pt3080CommsCurrentDNS1ServerAddress,
pt3080CommsCurrentDNS2ServerAddress,
pt3080CommsCurrentDNS3ServerAddress,
pt3080CommsStaticNtpServerAddress,
pt3080CommsCurrentNtpServerAddress,
pt3080CommsEmailServerAddress,
pt3080CommsWebServicePort,
pt3080CommsSCPIServicePort,
pt3080CommsSCPIServerBaudrate,
pt3080CommsSCPIUartInterface,
pt3080CommsRipPort,
pt3080CommsIGMPVersion,
pt3080CommsIGMPQueryRobustnessCount,
pt3080CommsIGMPv3UnsolicitedReportInterval,
pt3080CommsIGMPv2UnsolicitedReportInterval,
pt3080CommsAccessAllowed,
pt3080CommsAccessAllowedTimeout,
pt3080CommsAccessAllowedTimeLeft
}
STATUS current
DESCRIPTION
"Data network communications group"
::= { pt3080Groups 17}
pt3080DemodulatorGroup OBJECT-GROUP
OBJECTS {
pt3080DemodulatorFollowMode,
pt3080Demodulator1Available,
pt3080Demodulator2Available,
pt3080Demodulator1FWVersion,
pt3080Demodulator2FWVersion,
pt3080Demodulator1OutputTS,
pt3080Demodulator2OutputTS,
pt3080Demodulator1MerLimit,
pt3080Demodulator2MerLimit,
pt3080Demodulator1PreVirterbiErrorRateLimit,
pt3080Demodulator2PreVirterbiErrorRateLimit,
pt3080Demodulator1PostVirterbiErrorRateLimit,
pt3080Demodulator2PostVirterbiErrorRateLimit,
pt3080Demodulator1FelStatus,
pt3080Demodulator2FelStatus,
pt3080Demodulator1UncorrectedPackets,
pt3080Demodulator2UncorrectedPackets,
pt3080Demodulator1Mer,
pt3080Demodulator2Mer,
pt3080Demodulator1PreVirterbiErrorRate,
pt3080Demodulator2PreVirterbiErrorRate,
pt3080Demodulator1PostVirterbiErrorRate,
pt3080Demodulator2PostVirterbiErrorRate,
pt3080Demodulator1ActualGuardInterval,
pt3080Demodulator2ActualGuardInterval,
pt3080Demodulator1Actualifft,
pt3080Demodulator2Actualifft,
pt3080Demodulator1ActualConstellation,
pt3080Demodulator2ActualConstellation,
pt3080Demodulator1ActualHierarchy,
pt3080Demodulator2ActualHierarchy,
pt3080Demodulator1ActualCodeRateHighPrio,
pt3080Demodulator2ActualCodeRateHighPrio,
pt3080Demodulator1ActualCodeRateLowPrio,
pt3080Demodulator2ActualCodeRateLowPrio,
pt3080Demodulator1ActualDeepInterleaver,
pt3080Demodulator2ActualDeepInterleaver,
pt3080Demodulator1ActualMpeFecHighPrio,
pt3080Demodulator2ActualMpeFecHighPrio,
pt3080Demodulator1ActualMpeFecLowPrio,
pt3080Demodulator2ActualMpeFecLowPrio,
pt3080Demodulator1ActualTimeSlicingHighPrio,
pt3080Demodulator2ActualTimeSlicingHighPrio,
pt3080Demodulator1ActualTimeSlicingLowPrio,
pt3080Demodulator2ActualTimeSlicingLowPrio,
pt3080Demodulator1ActualCellID,
pt3080Demodulator2ActualCellID,
pt3080Demodulator1ActualDVBHMode,
pt3080Demodulator2ActualDVBHMode
}
STATUS current
DESCRIPTION
"Demodulator group"
::= { pt3080Groups 24}
pt3080PrecorrectorGroup OBJECT-GROUP
OBJECTS {
pt3080PrecorrectorLastTurnAroundTime,
pt3080PrecorrectorSecondsSinceLastUpdate,
pt3080PrecorrectorLinCleanrun,
pt3080PrecorrectorNlinCleanrun,
pt3080PrecorrectorLinearLoadNeutral,
pt3080PrecorrectorLinearLoadFactory,
pt3080PrecorrectorLinearUpdateFactoryCurve,
pt3080PrecorrectorNonlinearLoadNeutral,
pt3080PrecorrectorNonlinearLoadFactory,
pt3080PrecorrectorNonlinearUpdateFactoryCurve,
pt3080PrecorrectorLinearAdaptive,
pt3080PrecorrectorLinearMode,
pt3080PrecorrectorLinearSenseEnable,
pt3080PrecorrectorLinearMonitorStatus,
pt3080PrecorrectorLinearMonitorSenseLevel,
pt3080PrecorrectorLinearMonitorSenseValid,
pt3080PrecorrectorLinearMonitorSenseBadCount,
pt3080PrecorrectorLinearMonitorAmplitudeRipple,
pt3080PrecorrectorLinearMonitorAmplitudeRippleValid,
pt3080PrecorrectorLinearMonitorGroupDelay,
pt3080PrecorrectorLinearMonitorGroupDelayValid,
pt3080PrecorrectorLinearMonitorDiscartedIterations,
pt3080PrecorrectorLinearMonitorIterations,
pt3080PrecorrectorLinearAdaptiveMode,
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetLevel,
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleTargetHysteresis,
pt3080PrecorrectorLinearAdaptiveAmplitudeRippleEnable,
pt3080PrecorrectorLinearAdaptiveGroupDelayTargetLevel,
pt3080PrecorrectorLinearAdaptiveGroupDelayTargetHysteresis,
pt3080PrecorrectorLinearAdaptiveGroupDelayEnable,
pt3080PrecorrectorLinearAttenuation,
pt3080PrecorrectorNonlinearAdaptive,
pt3080PrecorrectorNonlinearMode,
pt3080PrecorrectorNonlinearSenseEnable,
pt3080PrecorrectorNonlinearMonitorStatus,
pt3080PrecorrectorNonlinearMonitorSenseLevel,
pt3080PrecorrectorNonlinearMonitorSenseValid,
pt3080PrecorrectorNonlinearMonitorSenseBadCount,
pt3080PrecorrectorNonlinearMonitorLowerShoulderLevel,
pt3080PrecorrectorNonlinearMonitorLowerShoulderValid,
pt3080PrecorrectorNonlinearMonitorUpperShoulderLevel,
pt3080PrecorrectorNonlinearMonitorUpperShoulderValid,
pt3080PrecorrectorNonlinearMonitorDiscartedIterations,
pt3080PrecorrectorNonlinearMonitorIterations,
pt3080PrecorrectorNonlinearMonitorMer,
pt3080PrecorrectorNonlinearMonitorMerValid,
pt3080PrecorrectorNonlinearMonitorPapr,
pt3080PrecorrectorNonlinearMonitorPaprValid,
pt3080PrecorrectorNonlinearAttenuation,
pt3080PrecorrectorNonlinearAdaptiveMode,
pt3080PrecorrectorNonlinearAdaptiveAveraging,
pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprEnable,
pt3080PrecorrectorNonlinearAdaptiveMaxRfPaprLimit,
pt3080PrecorrectorNonlinearAdaptiveMerTarget,
pt3080PrecorrectorNonlinearAdaptiveMerTargetHysteresis,
pt3080PrecorrectorNonlinearAdaptiveMerEnable,
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetLevel,
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderTargetHysteresis,
pt3080PrecorrectorNonlinearAdaptiveLowerShoulderEnable,
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetLevel,
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderTargetHysteresis,
pt3080PrecorrectorNonlinearAdaptiveUpperShoulderEnable,
pt3080PrecorrectorPaprClipping,
pt3080PrecorrectorPaprShaping,
pt3080PrecorrectorClipperMode,
pt3080PrecorrectorClipperAdaptive,
pt3080PrecorrectorClipperEnable,
pt3080PrecorrectorClipperAdaptiveMode,
pt3080PrecorrectorClipperAdaptiveShaping,
pt3080PrecorrectorClipperMonitorStatus,
pt3080PrecorrectorClipperMonitorShoulderLevelLower,
pt3080PrecorrectorClipperMonitorShoulderLevelLowerValid,
pt3080PrecorrectorClipperMonitorShoulderLevelUpper,
pt3080PrecorrectorClipperMonitorShoulderLevelUpperValid,
pt3080PrecorrectorClipperMonitorMer,
pt3080PrecorrectorClipperMonitorMerValid,
pt3080PrecorrectorClipperMonitorPapr,
pt3080PrecorrectorClipperMonitorPaprValid,
pt3080PrecorrectorClipperMonitorIterations
}
STATUS current
DESCRIPTION
"Precorrector group"
::= { pt3080Groups 25}
pt3080ReceptionGroup OBJECT-GROUP
OBJECTS {
pt3080ReceptionGainControl,
pt3080ReceptionGainManualValue,
pt3080ReceptionGainLimitEnable,
pt3080ReceptionGainLimit,
pt3080ReceptionGainCurrent,
pt3080ReceptionAGCMode,
pt3080ReceptionAGCHysteresis,
pt3080ReceptionBandwidth,
pt3080ReceptionRFFrequency,
pt3080ReceptionRFFrequencyOffset,
pt3080ReceptionRFPolarity,
pt3080ReceptionRFSquelchEnable,
pt3080ReceptionRFSquelchThreshold,
pt3080ReceptionRFSquelchHysteresis,
pt3080ReceptionRFTrackingFilterEnable,
pt3080ReceptionRFifLevel,
pt3080ReceptionRFNominalInputLevel,
pt3080ReceptionRFInputLevel,
pt3080ReceptionRFInputLevelThreshold,
pt3080ReceptionRFInputLevelHysteresis,
pt3080ReceptionIFFrequency,
pt3080ReceptionIFPolarity,
pt3080ReceptionIFInputLevel,
pt3080ReceptionIFInputPolicy,
pt3080ReceptionIFInput,
pt3080ReceptionIFRFtoIFHoldoverDelay,
pt3080ReceptionIFIFtoRFHoldoverDelay,
pt3080ReceptionTunerHWVersion,
pt3080ReceptionTunerHWType,
pt3080ReceptionTunerHWID,
pt3080ReceptionTunerHWSerialNumber,
pt3080ReceptionTunerHWCalibrationDate,
pt3080ReceptionTunerHWCalibrationDataVersion,
pt3080ReceptionTunerHWCalibrationSWVersion
}
STATUS current
DESCRIPTION
"Reception group"
::= { pt3080Groups 26}
pt3080BackplaneGroup OBJECT-GROUP
OBJECTS {
pt3080BackplanePolarityHardMute,
pt3080BackplanePolarityRFFail
}
STATUS current
DESCRIPTION
"Backplane group"
::= { pt3080Groups 27}
pt3080ASIGroup OBJECT-GROUP
OBJECTS {
pt3080ASIInput1SyncTimeout,
pt3080ASIInput2SyncTimeout,
pt3080ASIInput1DataErrorLimit,
pt3080ASIInput2DataErrorLimit,
pt3080ASIInput1SyncStatus,
pt3080ASIInput2SyncStatus,
pt3080ASIInput1SyncSignal,
pt3080ASIInput2SyncSignal,
pt3080ASIInput1SyncTSSize,
pt3080ASIInput2SyncTSSize,
pt3080ASIInput1LineErrors,
pt3080ASIInput2LineErrors,
pt3080ASIInput1LineRate,
pt3080ASIInput2LineRate,
pt3080ASIInput1LineErrorRate,
pt3080ASIInput2LineErrorRate,
pt3080ASIInput1DataErrors,
pt3080ASIInput2DataErrors,
pt3080ASIInput1DataRate,
pt3080ASIInput2DataRate,
pt3080ASIInput1DataErrorRate,
pt3080ASIInput2DataErrorRate,
pt3080ASIInput1ClearErrorCounters,
pt3080ASIInput2ClearErrorCounters
}
STATUS current
DESCRIPTION
"ASI media group"
::= { pt3080Groups 30}
pt3080NotifsGroup OBJECT-GROUP
OBJECTS {
pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime
}
STATUS current
DESCRIPTION
"Notification objects group"
::= { pt3080Groups 64 }
--
-- Agent Capability
--
pt3080Agent AGENT-CAPABILITIES
PRODUCT-RELEASE "SWPROTELEVISION_P3_1_02_157 build 1441106393"
STATUS current
DESCRIPTION "PT2080 DVB-T/H Modulator agent"
SUPPORTS PT2080-MIB
INCLUDES {
pt3080SystemGroup,
pt3080ModeGroup,
pt3080GpsGroup,
pt3080ChannelFilterGroup,
pt3080TSoIPGroup,
pt3080MonitorGroup,
pt3080TestGroup,
pt3080AlarmGroup,
pt3080PresetGroup,
pt3080EventlogGroup,
pt3080CommsGroup,
pt3080DemodulatorGroup,
pt3080BackplaneGroup,
pt3080ReceptionGroup,
pt3080ASIGroup
}
::= { pt3080Conformance 3 }
--
-- System Notifications (aka Traps)
--
pt3080NotificationsGroups OBJECT IDENTIFIER ::= { pt3080Conformance 4 }
pt3080NotifModulatorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Modulator Alarms"
::= { pt3080Notif 3 }
pt3080NotifTSPrimaryAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ASI TS Primary Alarms"
::= { pt3080Notif 5 }
pt3080NotifTSSecondaryAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ASI TS Secondary Alarms"
::= { pt3080Notif 6 }
pt3080NotifSFNAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"SFN Alarms"
::= { pt3080Notif 7 }
pt3080NotifRefenceClockAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Reference Alarms"
::= { pt3080Notif 8 }
pt3080NotifRFAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"RF Alarms"
::= { pt3080Notif 9 }
pt3080NotifGNSSAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Alarms"
::= { pt3080Notif 10 }
pt3080NotifTSoIPAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP Alarms"
::= { pt3080Notif 12 }
pt3080NotifExternalAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"External Alarms"
::= { pt3080Notif 13 }
pt3080NotifHWMonitorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"HW Monitor Alarms"
::= { pt3080Notif 14 }
pt3080NotifCommAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Communications Alarms"
::= { pt3080Notif 15 }
pt3080NotifASIAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ASI Alarms"
::= { pt3080Notif 16 }
pt3080NotifInternalAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Internal Alarms"
::= { pt3080Notif 18 }
pt3080NotifTSPrimarySyncLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Sync Loss"
::= { pt3080Notif 21 }
pt3080NotifTSPrimarySyncErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Sync Error"
::= { pt3080Notif 22 }
pt3080NotifTSPrimaryPCRErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary PCR Error"
::= { pt3080Notif 23 }
pt3080NotifTSPrimaryPATLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary PAT Loss"
::= { pt3080Notif 24 }
pt3080NotifTSPrimaryTSIDWrongAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Transport Stream ID"
::= { pt3080Notif 25 }
pt3080NotifTSPrimaryNWIDWrongAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Network ID"
::= { pt3080Notif 26 }
pt3080NotifTSPrimaryStuffingRateExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Stuffing Rate"
::= { pt3080Notif 27 }
pt3080NotifTSPrimaryBufferPoolExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Buffer Pool"
::= { pt3080Notif 28 }
pt3080NotifTSPrimarySTSJitterExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary STS Jitter"
::= { pt3080Notif 29 }
pt3080NotifTSPrimaryMIPDataMissingAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary MIP Data Missing"
::= { pt3080Notif 30 }
pt3080NotifTSPrimaryMIPPriorityBadAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Bad Priority in MIP"
::= { pt3080Notif 31 }
pt3080NotifTSSecondarySyncLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Sync Loss"
::= { pt3080Notif 32 }
pt3080NotifTSSecondarySyncErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Sync Error"
::= { pt3080Notif 33 }
pt3080NotifTSSecondaryPCRErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary PCR Error"
::= { pt3080Notif 34 }
pt3080NotifTSSecondaryPATLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary PAT Loss"
::= { pt3080Notif 35 }
pt3080NotifTSSecondaryTSIDWrongAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Transport Stream ID"
::= { pt3080Notif 36 }
pt3080NotifTSSecondaryNWIDWrongAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Network ID"
::= { pt3080Notif 37 }
pt3080NotifTSSecondaryStuffingRateExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Stuffing Rate"
::= { pt3080Notif 38 }
pt3080NotifTSSecondaryBufferPoolExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Buffer Pool"
::= { pt3080Notif 39 }
pt3080NotifTSSecondarySTSJitterExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary STS Jitter"
::= { pt3080Notif 40 }
pt3080NotifTSSecondaryMIPDataMissingAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary MIP Data Missing"
::= { pt3080Notif 41 }
pt3080NotifTSSecondaryMIPPriorityBadAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Bad Priority in MIP"
::= { pt3080Notif 42 }
pt3080NotifRFOverloadProtectionAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Overload Protection"
::= { pt3080Notif 44 }
pt3080NotifCommeth0Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ETH0 Conn. State"
::= { pt3080Notif 55 }
pt3080NotifCommeth1Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ETH1 Conn. State"
::= { pt3080Notif 56 }
pt3080NotifCommeth2Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ETH2 Conn. State"
::= { pt3080Notif 57 }
pt3080NotifCommeth3Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ETH3 Conn. State"
::= { pt3080Notif 58 }
pt3080NotifCommeth4Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ETH4 Conn. State"
::= { pt3080Notif 59 }
pt3080NotifExternalInput1Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 1"
::= { pt3080Notif 72 }
pt3080NotifExternalInput2Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 2"
::= { pt3080Notif 73 }
pt3080NotifExternalInput3Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 3"
::= { pt3080Notif 74 }
pt3080NotifExternalInput4Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 4"
::= { pt3080Notif 75 }
pt3080NotifRefenceClockExtern1PPSLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 1PPS Loss"
::= { pt3080Notif 76 }
pt3080NotifRefenceClockIntern1PPSLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Int. 10MHz Loss"
::= { pt3080Notif 77 }
pt3080NotifRefenceClockExtern10MHzLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 10MHz Loss"
::= { pt3080Notif 78 }
pt3080NotifRFAlcRangeAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ALC Range"
::= { pt3080Notif 79 }
pt3080NotifSFNResyncAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"SFN Resync Error"
::= { pt3080Notif 80 }
pt3080NotifSFNTSPrimaryMaxDelayOffsetExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Primary SFN Max Delay + Offset OOR"
::= { pt3080Notif 81 }
pt3080NotifSFNTSPrimaryNetworkDelayExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Primary SFN NW Delay Greater Than Max"
::= { pt3080Notif 82 }
pt3080NotifSFNTSSecondaryMaxDelayOffsetExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Secondary SFN Max. Delay + Offset OOR"
::= { pt3080Notif 84 }
pt3080NotifSFNTSSecondaryNetworkDelayExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Secondary SFN NW Delay Greater Than Max"
::= { pt3080Notif 85 }
pt3080NotifRFLevelOutOfRangeAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"RF Level Out of Range"
::= { pt3080Notif 87 }
pt3080NotifRefenceClockNTPSyncLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"NTP Sync Loss"
::= { pt3080Notif 89 }
pt3080NotifSFNTSPrimarySeamlessDelayTooSmallAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Primary Delay Margin too Small for Seamless and Holdover"
::= { pt3080Notif 92 }
pt3080NotifSFNTSPrimaryMIPConfigErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Primary SFN and MIP Config Differ"
::= { pt3080Notif 93 }
pt3080NotifSFNTSSecondarySeamlessDelayTooSmallAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Secondary Delay Margin too Small for Seamless and Holdover"
::= { pt3080Notif 94 }
pt3080NotifSFNTSSecondaryMIPConfigErrorAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Secondary SFN and MIP Config Differ"
::= { pt3080Notif 95 }
pt3080NotifGNSSUnlockedAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Unlocked"
::= { pt3080Notif 98 }
pt3080NotifGNSSAntennaFaultAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Antenna Fault"
::= { pt3080Notif 107 }
pt3080NotifGNSSHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Holdover"
::= { pt3080Notif 108 }
pt3080NotifRefenceClockExternal10MHzHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 10MHz Ref Holdover"
::= { pt3080Notif 109 }
pt3080NotifRefenceClockExternal1PPSHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 1PPS Ref Holdover"
::= { pt3080Notif 110 }
pt3080NotifASIASI1ErrorRateEceeededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ASI-IN1 Error Rate"
::= { pt3080Notif 113 }
pt3080NotifASIASI2ErrorRateEceeededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"ASI-IN2 Error Rate"
::= { pt3080Notif 114 }
pt3080NotifTSoIPRx1PackageErrorRationExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP RX1 Package Error Ratio Exceeded"
::= { pt3080Notif 115 }
pt3080NotifTSoIPRx2PackageErrorRationExceededAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP RX2 Package Error Ratio Exceeded"
::= { pt3080Notif 117 }
pt3080NotifTSoIPRx1SyncLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP RX1 Signal Loss"
::= { pt3080Notif 119 }
pt3080NotifTSoIPRx2SyncLossAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP RX2 Signal Loss"
::= { pt3080Notif 121 }
pt3080NotifInternalBackplaneAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Backplane Status"
::= { pt3080Notif 129 }
pt3080NotifInternalReferenceClockAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Reference Status"
::= { pt3080Notif 132 }
pt3080NotifInternalUpConverterAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Upconverter Status"
::= { pt3080Notif 134 }
pt3080NotifInternalDownConverterAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Downconverter Status"
::= { pt3080Notif 135 }
pt3080NotifInternalMainboardAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Main board Status"
::= { pt3080Notif 136 }
pt3080NotifInternalBatteryAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Main Board Battery"
::= { pt3080Notif 137 }
pt3080NotifInternalFirmware1Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Firmware 1 Status"
::= { pt3080Notif 139 }
pt3080NotifInternalGNSSAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Status"
::= { pt3080Notif 142 }
pt3080NotifInternalSatelliteAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Satrecv Status"
::= { pt3080Notif 143 }
pt3080NotifInternalEthAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"EtherNet Port Failure"
::= { pt3080Notif 146 }
pt3080NotifHWMonitorFPGAAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Main Board FPGA Temperature"
::= { pt3080Notif 156 }
pt3080NotifHWMonitorMainBoardCPUTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Main Board CPU Temperature"
::= { pt3080Notif 157 }
pt3080NotifHWMonitorMainBoardTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Main Board Temperature"
::= { pt3080Notif 158 }
pt3080NotifHWMonitorLeftFanAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Left Chassis Fan"
::= { pt3080Notif 159 }
pt3080NotifHWMonitorRightFan2Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Right Chassis Fan"
::= { pt3080Notif 160 }
pt3080NotifHWMonitorBackplaneTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Backplane Temperature"
::= { pt3080Notif 162 }
pt3080NotifTSPrimaryInputTSHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Input TS Holdover"
::= { pt3080Notif 180 }
pt3080NotifInternalPLLUnlockedAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"PLL Out of Lock"
::= { pt3080Notif 182 }
pt3080NotifExternalInput5Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 5"
::= { pt3080Notif 183 }
pt3080NotifSFNUntimedModeAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"SFN Mode Untimed"
::= { pt3080Notif 184 }
pt3080NotifSFNFreeRunningModeAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"SFN Mode Free Running"
::= { pt3080Notif 185 }
pt3080NotifExternalInput6Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 6"
::= { pt3080Notif 186 }
pt3080NotifExternalInput7Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 7"
::= { pt3080Notif 187 }
pt3080NotifExternalInput8Alarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 8"
::= { pt3080Notif 188 }
pt3080NotifTSPrimaryDelayMarginAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Delay Margin"
::= { pt3080Notif 190 }
pt3080NotifTSSecondaryDelayMarginAlarm NOTIFICATION-TYPE
OBJECTS { pt3080NotifMessage, pt3080NotifState, pt3080NotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Delay Margin"
::= { pt3080Notif 191 }
pt3080NotifGroupModulatorAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifModulatorAlarm
}
STATUS current
DESCRIPTION
"Modulator Alarms"
::= { pt3080NotificationsGroups 3 }
pt3080NotifGroupTSPrimaryAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifTSPrimaryAlarm,
pt3080NotifTSPrimarySyncLossAlarm,
pt3080NotifTSPrimarySyncErrorAlarm,
pt3080NotifTSPrimaryPCRErrorAlarm,
pt3080NotifTSPrimaryPATLossAlarm,
pt3080NotifTSPrimaryTSIDWrongAlarm,
pt3080NotifTSPrimaryNWIDWrongAlarm,
pt3080NotifTSPrimaryStuffingRateExceededAlarm,
pt3080NotifTSPrimaryBufferPoolExceededAlarm,
pt3080NotifTSPrimarySTSJitterExceededAlarm,
pt3080NotifTSPrimaryMIPDataMissingAlarm,
pt3080NotifTSPrimaryMIPPriorityBadAlarm,
pt3080NotifTSPrimaryInputTSHoldOverAlarm,
pt3080NotifTSPrimaryDelayMarginAlarm
}
STATUS current
DESCRIPTION
"ASI TS Primary Alarms"
::= { pt3080NotificationsGroups 5 }
pt3080NotifGroupTSSecondaryAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifTSSecondaryAlarm,
pt3080NotifTSSecondarySyncLossAlarm,
pt3080NotifTSSecondarySyncErrorAlarm,
pt3080NotifTSSecondaryPCRErrorAlarm,
pt3080NotifTSSecondaryPATLossAlarm,
pt3080NotifTSSecondaryTSIDWrongAlarm,
pt3080NotifTSSecondaryNWIDWrongAlarm,
pt3080NotifTSSecondaryStuffingRateExceededAlarm,
pt3080NotifTSSecondaryBufferPoolExceededAlarm,
pt3080NotifTSSecondarySTSJitterExceededAlarm,
pt3080NotifTSSecondaryMIPDataMissingAlarm,
pt3080NotifTSSecondaryMIPPriorityBadAlarm,
pt3080NotifTSSecondaryDelayMarginAlarm
}
STATUS current
DESCRIPTION
"ASI TS Secondary Alarms"
::= { pt3080NotificationsGroups 6 }
pt3080NotifGroupSFNAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifSFNAlarm,
pt3080NotifSFNResyncAlarm,
pt3080NotifSFNTSPrimaryMaxDelayOffsetExceededAlarm,
pt3080NotifSFNTSPrimaryNetworkDelayExceededAlarm,
pt3080NotifSFNTSSecondaryMaxDelayOffsetExceededAlarm,
pt3080NotifSFNTSSecondaryNetworkDelayExceededAlarm,
pt3080NotifSFNTSPrimarySeamlessDelayTooSmallAlarm,
pt3080NotifSFNTSPrimaryMIPConfigErrorAlarm,
pt3080NotifSFNTSSecondarySeamlessDelayTooSmallAlarm,
pt3080NotifSFNTSSecondaryMIPConfigErrorAlarm,
pt3080NotifSFNUntimedModeAlarm,
pt3080NotifSFNFreeRunningModeAlarm
}
STATUS current
DESCRIPTION
"SFN Alarms"
::= { pt3080NotificationsGroups 7 }
pt3080NotifGroupRefenceClockAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifRefenceClockAlarm,
pt3080NotifRefenceClockExtern1PPSLossAlarm,
pt3080NotifRefenceClockIntern1PPSLossAlarm,
pt3080NotifRefenceClockExtern10MHzLossAlarm,
pt3080NotifRefenceClockNTPSyncLossAlarm,
pt3080NotifRefenceClockExternal10MHzHoldOverAlarm,
pt3080NotifRefenceClockExternal1PPSHoldOverAlarm
}
STATUS current
DESCRIPTION
"Reference Alarms"
::= { pt3080NotificationsGroups 8 }
pt3080NotifGroupRFAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifRFAlarm,
pt3080NotifRFOverloadProtectionAlarm,
pt3080NotifRFAlcRangeAlarm,
pt3080NotifRFLevelOutOfRangeAlarm
}
STATUS current
DESCRIPTION
"RF Alarms"
::= { pt3080NotificationsGroups 9 }
pt3080NotifGroupGNSSAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifGNSSAlarm,
pt3080NotifGNSSUnlockedAlarm,
pt3080NotifGNSSAntennaFaultAlarm,
pt3080NotifGNSSHoldOverAlarm
}
STATUS current
DESCRIPTION
"GNSS Alarms"
::= { pt3080NotificationsGroups 10 }
pt3080NotifGroupTSoIPAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifTSoIPAlarm,
pt3080NotifTSoIPRx1PackageErrorRationExceededAlarm,
pt3080NotifTSoIPRx2PackageErrorRationExceededAlarm,
pt3080NotifTSoIPRx1SyncLossAlarm,
pt3080NotifTSoIPRx2SyncLossAlarm
}
STATUS current
DESCRIPTION
"TSoIP Alarms"
::= { pt3080NotificationsGroups 12 }
pt3080NotifGroupExternalAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifExternalAlarm,
pt3080NotifExternalInput1Alarm,
pt3080NotifExternalInput2Alarm,
pt3080NotifExternalInput3Alarm,
pt3080NotifExternalInput4Alarm,
pt3080NotifExternalInput5Alarm,
pt3080NotifExternalInput6Alarm,
pt3080NotifExternalInput7Alarm,
pt3080NotifExternalInput8Alarm
}
STATUS current
DESCRIPTION
"External Alarms"
::= { pt3080NotificationsGroups 13 }
pt3080NotifGroupHWMonitorAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifHWMonitorAlarm,
pt3080NotifHWMonitorFPGAAlarm,
pt3080NotifHWMonitorMainBoardCPUTemperatureAlarm,
pt3080NotifHWMonitorMainBoardTemperatureAlarm,
pt3080NotifHWMonitorLeftFanAlarm,
pt3080NotifHWMonitorRightFan2Alarm,
pt3080NotifHWMonitorBackplaneTemperatureAlarm
}
STATUS current
DESCRIPTION
"HW Monitor Alarms"
::= { pt3080NotificationsGroups 14 }
pt3080NotifGroupCommAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifCommAlarm,
pt3080NotifCommeth0Alarm,
pt3080NotifCommeth1Alarm,
pt3080NotifCommeth2Alarm,
pt3080NotifCommeth3Alarm,
pt3080NotifCommeth4Alarm
}
STATUS current
DESCRIPTION
"Communications Alarms"
::= { pt3080NotificationsGroups 15 }
pt3080NotifGroupASIAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifASIAlarm,
pt3080NotifASIASI1ErrorRateEceeededAlarm,
pt3080NotifASIASI2ErrorRateEceeededAlarm
}
STATUS current
DESCRIPTION
"ASI Alarms"
::= { pt3080NotificationsGroups 16 }
pt3080NotifGroupInternalAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
pt3080NotifInternalAlarm,
pt3080NotifInternalBackplaneAlarm,
pt3080NotifInternalReferenceClockAlarm,
pt3080NotifInternalUpConverterAlarm,
pt3080NotifInternalDownConverterAlarm,
pt3080NotifInternalMainboardAlarm,
pt3080NotifInternalBatteryAlarm,
pt3080NotifInternalFirmware1Alarm,
pt3080NotifInternalGNSSAlarm,
pt3080NotifInternalSatelliteAlarm,
pt3080NotifInternalEthAlarm,
pt3080NotifInternalPLLUnlockedAlarm
}
STATUS current
DESCRIPTION
"Internal Alarms"
::= { pt3080NotificationsGroups 18 }
END