--MibName=raisecomOpticalMonitorMIB
-- *****************************************************************
-- RAISECOM-OPTICAL-TRANSCEIVER-MIB.my
--
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
-- All rights reserved.
-- *****************************************************************
-- *****************************************************************
-- Modi Report£ºFormat: <number>, <time>, <author>, <desc>
-- 01, 20110623, yangzhognhong, change the value of the node raisecomOpticalTransceiverMediaType
-- for SFP+ development
--
-- *****************************************************************
RAISECOM-OPTICAL-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32, Unsigned32,
MODULE-IDENTITY,
NOTIFICATION-TYPE,
OBJECT-TYPE,
TimeTicks FROM SNMPv2-SMI
raisecomAgent
FROM RAISECOM-BASE-MIB
TEXTUAL-CONVENTION FROM SNMPv2-TC
MODULE-COMPLIANCE,
NOTIFICATION-GROUP,
OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
raisecomNotificationLocation FROM RAISECOM-COMMON-MANAGEMENT-MIB
ClearVar FROM SWITCH-TC;
raisecomOpticalTransceiver MODULE-IDENTITY
LAST-UPDATED "201005190000Z"
ORGANIZATION "Raisecom, Inc."
CONTACT-INFO
" Raise Systems
Postal: Beijing,
China
Tel: 86-010-82884499
E-mail: chenyu@raisecom.com"
DESCRIPTION
"This MIB module defines objects to monitor optical
characteristics on the optical interfaces in a network element. "
REVISION "201005190000Z"
DESCRIPTION
"The initial revision of this MIB."
::={ raisecomAgent 18 }
-- Textual Conventions
EnableVar ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"enable or disable a function."
SYNTAX INTEGER {
enable(1),
disable(2)
}
OpticalParameterType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the optical parameter that is
being monitored. Valid values are -OpticalParameterType
transceiverTemperature(1) :transceiver temperature
txbiasCurrent(2) :TX bias current
txPower(3) :TX output power
rxPower(4) :RX received optical power
laserTemperature(5) :laser temperature
p5V0supplyVoltage(6) :+5V supply voltage
p3V3supplyVoltage(7) :+3.3V supply voltage
p1V8supplyVoltage(8) :+1.8V supply voltage
n5V2supplyVoltage(9) :-5.2V supply voltage
apdBiasVoltage(10) :APD bias voltage
p5V0supplyCurrent(11) :+5V supply currnet
p3V3supplyCurrent(12) :+3.3V supply currnet
p1V8supplyCurrent(13) :+1.8V supply currnet
n5V2supplyCurrent(14) :-5.2V supply currnet
tecCurrent(15) :TEC currnet
laserWavelength(16) :laser wavelength
"
SYNTAX INTEGER {
transceiverTemperature (1),
txbiasCurrent (2),
txPower (3),
rxPower (4),
laserTemperature(5),
p5V0supplyVoltage(6),
p3V3supplyVoltage(7),
p1V8supplyVoltage(8),
n5V2supplyVoltage(9),
apdBiasVoltage(10),
p5V0supplyCurrent(11),
p3V3supplyCurrent(12),
p1V8supplyCurrent(13),
n5V2supplyCurrent(14),
tecCurrent(15),
laserWavelength(16)
}
OpticalParameterValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical parameter being monitored,
as identified by a corresponding object with syntax OpticalParameterType.
When the optical parameter being monitored is 'XXTemperature',the supported range
is from -40000 to 125000, in units of 1/1000 degrees centigrade.
Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
The temperature is shown in unit of degrees centigrade, and the precision is 0.1.
When the optical parameter being monitored is 'txbiasCurrent',the supported range
is from 0 to 131000, in units of 1/1000 mA.
Example: A value of 1000 represents a TX bias current reading of 1.0mA.
The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'txPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
The 'txPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'rxPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm.
The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
is from 0 to 6550, in units of 1/1000 V.
Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
When the optical parameter being monitored is 'apdBiasVoltage,the supported range
is from 0 to 655300 , in units of 1/1000 V .
Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a XX supply current reading of 6000.0mA.
The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'tecCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'laserWavelength,the supported range
is from 0 to 3276750, in units of 1/1000 nm .
Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
"
SYNTAX Integer32 (-1000000 | -40000..6553600)
OpticalPMPeriod ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the time period over which performance
monitoring data has been collected."
SYNTAX INTEGER {
fifteenMin(1),
twentyFourHour(2)
}
-- MIB Global Enable Definitions
raisecomOpticalTransceiverGlobalEnable OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiver 1 }
raisecomOpticalTransceiverNotifyEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the generation of device notifications,
enable or disable.
this object belongs to xfp and sfp.
"
DEFVAL { disable }
::={ raisecomOpticalTransceiverGlobalEnable 1 }
raisecomOpticalTransceiverDDMEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable digitaldiagnotic on the device.
this object belongs to xfp and sfp.
"
DEFVAL { disable}
::={ raisecomOpticalTransceiverGlobalEnable 2 }
raisecomOpticalTransceiverCheckPwdEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of password checking on the device,
enable or disable.
this object belongs to xfp.
"
DEFVAL { disable}
::={ raisecomOpticalTransceiverGlobalEnable 3 }
raisecomOpticalTransceiverPollInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the value of poll-interval on the device.
this object belongs to xfp and sfp.
"
::={ raisecomOpticalTransceiverGlobalEnable 4 }
-- MIB Object Definitions
raisecomOpticalTransceiverObjects OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiver 2 }
-- groups in this MIB module
raisecomOpticalTransceiverInfoGroup OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiverObjects 1 }
raisecomOpticalTransceiverDDMGroup OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiverObjects 2 }
raisecomOpticalTransceiverPMGroup OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiverObjects 3 }
raisecomOpticalTransceiverStatusGroup OBJECT IDENTIFIER ::=
{raisecomOpticalTransceiverObjects 4 }
-- raisecomOpticalTransceiverInfoTable
raisecomOpticalTransceiverInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomOpticalTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trancetver information Table."
::= { raisecomOpticalTransceiverInfoGroup 1 }
raisecomOpticalTransceiverInfoEntry OBJECT-TYPE
SYNTAX RaisecomOpticalTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the raisecomOpticalTransceiverInfoTable."
INDEX { ifIndex }
::={ raisecomOpticalTransceiverInfoTable 1 }
RaisecomOpticalTransceiverInfoEntry ::= SEQUENCE {
raisecomOpticalTransceiverType INTEGER,
raisecomOpticalTransceiverConnectorType INTEGER,
raisecomOpticalTransceiverVendorName OCTET STRING,
raisecomOpticalTransceiverVendorPN OCTET STRING,
raisecomOpticalTransceiverVendorSN OCTET STRING,
raisecomOpticalTransceiverMediaType INTEGER,
raisecomOpticalTransceiverTransmissionDistance Integer32,
raisecomOpticalTransceiverAbility Unsigned32,
raisecomOpticalTransceiverDDM INTEGER,
raisecomOpticalTransceiverCalibrationType INTEGER,
raisecomOpticalTransceiverRSSI INTEGER,
raisecomOpticalTransceiverVendorRev OCTET STRING,
raisecomOpticalTransceiverBRMax INTEGER,
raisecomOpticalTransceiverBRMin INTEGER,
raisecomOpticalTransceiverWavelengthContrl INTEGER,
raisecomOpticalTransceiverWavelength Integer32,
raisecomOpticalTransceiverWaveTolerance OCTET STRING,
raisecomOpticalTransceiverCompatibility OCTET STRING,
raisecomOpticalTransceiverPowerDissipation INTEGER,
raisecomOpticalTransceiverCDR INTEGER,
raisecomOpticalTransceiverRefClock INTEGER,
raisecomOpticalTransceiverTransmitterType INTEGER,
raisecomOpticalTransceiverCooled INTEGER,
raisecomOpticalTransceiverTunalbe INTEGER,
raisecomOpticalTransceiverDetectorType INTEGER,
raisecomOpticalTransceiverLineLoopBack INTEGER,
raisecomOpticalTransceiverXFILoopBack INTEGER,
raisecomOpticalTransceiverVps INTEGER,
raisecomOpticalTransceiverTxDis INTEGER,
raisecomOpticalTransceiverStandby INTEGER,
raisecomOpticalTransceiverInVpsLowPower INTEGER,
raisecomOpticalTransceiverOutVpsLowPower INTEGER,
raisecomOpticalTransceiverFEC INTEGER,
raisecomOpticalTransceiverCMU INTEGER,
raisecomOpticalTransceiverBR INTEGER
}
raisecomOpticalTransceiverType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
gbic(2),
soldered(3),
sfp(4),
xbi(5),
xenpak(6),
xfp(7),
xff(8),
xfp-e(9),
xpak(10),
x2(11),
sfpj(12)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the physical type of the transceiver,
such as xfp or sfp , and so on.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 1 }
raisecomOpticalTransceiverConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
sc (1),
db9(2),
hssdc(3),
bnc-tnc(4),
fiber-coaxial-head(5),
fiber-jack(6),
lc(7),
mt-rj(8),
mu(9),
sg(10),
fiber-pigtail(11),
mpo-parallel-optic(12),
hssdcII (20),
copper (21),
rj45 (22)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the connector type of the transceiver£¬
unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet,
lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII,
copper, rj45.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 2 }
raisecomOpticalTransceiverVendorName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
"Vendor name of the interface.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 3 }
raisecomOpticalTransceiverVendorPN OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
"Vendor part number of the interface.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 4 }
raisecomOpticalTransceiverVendorSN OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
"Vendor serial number of the interface.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 5 }
raisecomOpticalTransceiverMediaType OBJECT-TYPE
SYNTAX INTEGER
{
single-mode(1),
multi-modeE50(2),
multi-mode50(3),
multi-mode625(4),
copper(5),
single-modeKm(6),
multi-modeOM3(7)
}
ACCESS read-only
STATUS current
DESCRIPTION
"Types of the fiber,
single_mode, multi_modeE50, multi_mode50,multi_mode625,copper.
single_modeKm,multi_modeOM3
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 6 }
raisecomOpticalTransceiverTransmissionDistance OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION
"The max distance which the interface could transmit,
measured in meter.
The object will be shown in unit of Km, and the precision is 0.001.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 7 }
raisecomOpticalTransceiverAbility OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the ability of optical module digitaldiagnotic
funtion. Currently, the digitaldiagnotic objects of our optical module
inculde 16 parameters.
this object has 32 bits, each bit represents a digital diagnotic parameter.
if the bit value is 0, it means that the optical module does not provide
digital diagnotic funtion for relative parameter.if the bit value is 1,it
means that the optical module provides digital diagnotic funtion for
relative parameter.
this object belongs to xfp and sfp.
The relation between parameters and bits is following:
32¡­¡­16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
The relation between parameters and bits is following:
32¡­¡­16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
| 1bit | 2bit | 3bit | 4bit
| APDÆ«Öõçѹ | 0£¨±£Áô£© | TECµçÁ÷ | ¼¤¹âÆ÷ζÈ
| 5bit | 6bit |7bit | 8bit
| ¼¤¹âÆ÷²¨³¤ | +5V¹©µçµçѹ | +3.3V¹©µçµçѹ | +1.8V¹©µçµçѹ
| 9bit | 10bit |11bit | 12bit
| -5.2V¹©µçµçѹ | +5V¹©µçµçÁ÷ | 0£¨ÎÞ£© | 0£¨ÎÞ£©
| 13bit | 14bit | 15bit | 16bit
| +3.3V¹©µçµçÁ÷ | +1.8V¹©µçµçÁ÷ | -5.2V¹©µçµçÁ÷ | Ä£¿éζÈ
| 17bit | 18bit | 19bit | 20bit ~ 32bit
| ¼¤¹âÆ÷Æ«ÖõçÁ÷ | ·¢Ë͹⹦ÂÊ |½ÓÊչ⹦ÂÊ | 0
But when the optical module is sfp, the 6 bit will represents
the supplyVoltage of sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 8 }
raisecomOpticalTransceiverDDM OBJECT-TYPE
SYNTAX INTEGER{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the transceiver supports on digital diagnostic function,
support or not support.To the xfp, the default value of this object is support.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 9 }
raisecomOpticalTransceiverCalibrationType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
internal(2),
external(3)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the calibration type of the transceiver,
internal, external, unknown.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 10 }
raisecomOpticalTransceiverRSSI OBJECT-TYPE
SYNTAX INTEGER{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the calibration type of the transceiver,
support or not support.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 11 }
raisecomOpticalTransceiverVendorRev OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
" the version number of the transceiver.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 12 }
raisecomOpticalTransceiverBRMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
" the min data rate of the transceiver,mesured in Mbps .
this object belongs to xfp and sfp.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::= { raisecomOpticalTransceiverInfoEntry 13 }
raisecomOpticalTransceiverBRMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS current
DESCRIPTION
" the min data rate of the transceiver,mesured in Mbps.
this object belongs to xfp and sfp.To the sfp,
the min data rate value is equal to the max data rate value.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::= { raisecomOpticalTransceiverInfoEntry 14 }
raisecomOpticalTransceiverWavelengthContrl OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport (2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"if the transceiver supports on wavelength control
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 15 }
raisecomOpticalTransceiverWavelength OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION
"Wavelength of the interface, measured in pm(0.001nm).
this object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::= { raisecomOpticalTransceiverInfoEntry 16 }
raisecomOpticalTransceiverWaveTolerance OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
"the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm).
this object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::= { raisecomOpticalTransceiverInfoEntry 17 }
raisecomOpticalTransceiverCompatibility OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION
"the compatibility type that the transceiver supports,such as 10GBASE-SR.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 18 }
raisecomOpticalTransceiverPowerDissipation OBJECT-TYPE
SYNTAX INTEGER
{
p1W5(1),
p2W5(2),
p3W5(3),
exceed(4)
}
ACCESS read-only
STATUS current
DESCRIPTION
"the max power dissipation of the transceiver,
p1W5,p2W5,p3W5,exceed3W5.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 19 }
raisecomOpticalTransceiverCDR OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"the optical module supports on CDR fundtion.
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 20 }
raisecomOpticalTransceiverRefClock OBJECT-TYPE
SYNTAX INTEGER
{
required(1),
notrequired (2)
}
ACCESS read-only
STATUS current
DESCRIPTION
" if the transceiver requires outside reference clock
required,notrequired.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 21 }
raisecomOpticalTransceiverTransmitterType OBJECT-TYPE
SYNTAX INTEGER
{
vcsel850nm(1),
vcsel1310nm(2),
vcsel1550nm(3),
fp1310nm(4),
dfb1310nm(5),
dfb1550nm(6),
eml1310nm(7),
eml1550nm(8),
copper-others(9)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter type of the transceiver,such as 850 nm VCSEL.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 22 }
raisecomOpticalTransceiverCooled OBJECT-TYPE
SYNTAX INTEGER
{
cooled(1),
uncooled (2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter cooled type of the transceiver
cooled,uncooled.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 24 }
raisecomOpticalTransceiverTunalbe OBJECT-TYPE
SYNTAX INTEGER
{
tunable (1),
untunable (2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter tunable type of the transceiver
tunable,untunable.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 25 }
raisecomOpticalTransceiverDetectorType OBJECT-TYPE
SYNTAX INTEGER
{
pin(1),
apd(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The detector type of the transceiver
pin, apd.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 26 }
raisecomOpticalTransceiverLineLoopBack OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of sideline loop-back control
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 27 }
raisecomOpticalTransceiverXFILoopBack OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of XFI loop-back control
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 28 }
raisecomOpticalTransceiverVps OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module supports on VPS
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 29 }
raisecomOpticalTransceiverTxDis OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of software control the transmitter status
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 30 }
raisecomOpticalTransceiverStandby OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of software control the standby mode.
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 31 }
raisecomOpticalTransceiverInVpsLowPower OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The VPS in low power support status of the transceiver
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 32 }
raisecomOpticalTransceiverOutVpsLowPower OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The VPS out low power support status of the transceiver
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 33 }
raisecomOpticalTransceiverFEC OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The FEC support status of transceiver
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 34 }
raisecomOpticalTransceiverCMU OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
ACCESS read-only
STATUS current
DESCRIPTION
"The CMU support status of transceiver
support,notsupport.
this object belongs to xfp.
"
::= { raisecomOpticalTransceiverInfoEntry 35 }
raisecomOpticalTransceiverBR OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
bitrate-125Mbps(1),
bitrate-155Mbps (2),
bitrate-622Mbps(6),
bitrate-1DOT25Gbps(13),
bitrate-2DOT5Gbps(19)
}
ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Nominal bitrate of the transceiver£¬
125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps.
this object belongs to xfp and sfp.
"
::= { raisecomOpticalTransceiverInfoEntry 36 }
-- raisecomOpticalDDMTable
raisecomOpticalTransceiverDDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomOpticalTransceiverDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides objects to monitor optical
parameters in a network element. "
::={ raisecomOpticalTransceiverDDMGroup 1 }
raisecomOpticalTransceiverDDMEntry OBJECT-TYPE
SYNTAX RaisecomOpticalTransceiverDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the raisecomOpticalTransceiverMonTable provides objects to
monitor an optical parameter at an optical interface.
"
INDEX { ifIndex,
raisecomOpticalTransceiverParameterType
}
::={ raisecomOpticalTransceiverDDMTable 1 }
RaisecomOpticalTransceiverDDMEntry ::= SEQUENCE {
raisecomOpticalTransceiverParameterType OpticalParameterType,
raisecomOpticalTransceiverParameterValue OpticalParameterValue,
raisecomOpticalTransceiverParamHighAlarmThresh OpticalParameterValue,
raisecomOpticalTransceiverParamHighWarningThresh OpticalParameterValue,
raisecomOpticalTransceiverParamLowAlarmThresh OpticalParameterValue,
raisecomOpticalTransceiverParamLowWarningThresh OpticalParameterValue,
raisecomOpticalTransceiverParamAlarmStatus INTEGER,
raisecomOpticalTransceiverParamAlarmLastValue OpticalParameterValue,
raisecomOpticalTransceiverParamAlarmLastChange TimeTicks,
raisecomOpticalTransceiverDDM15MinValidIntervals Unsigned32,
raisecomOpticalTransceiverDDM24HrValidIntervals Unsigned32,
raisecomOpticalTransceiverDDMValidStatus INTEGER
}
raisecomOpticalTransceiverParameterType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored in this entry.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 1 }
raisecomOpticalTransceiverParameterValue OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the value measured for the particular
optical parameter specified by the raisecomOpticalMonParameterType
object.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 2 }
raisecomOpticalTransceiverParamHighAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the high alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
raisecomOpticalParameterValue goes from below the value of
this object to above the value of this object, or if
the initial value of raisecomOpticalParameterValue exceeds the value
of this object. This alarm will be indicated in the
raisecomOpticalParamAlarmStatus object.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 3 }
raisecomOpticalTransceiverParamHighWarningThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a high warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by raisecomOpticalParameterValue goes from below the value
of this object to above the value of this
object, or if the initial value of raisecomOpticalParameterValue
exceeds the value of this object. This alarm will be indicated in the
raisecomOpticalParamAlarmStatus object.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 4 }
raisecomOpticalTransceiverParamLowAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
raisecomOpticalParameterValue goes from above the value of
this object to below the value of this object, or if
the initial value of raisecomOpticalParameterValue is lower than the
value of this object. This alarm
will be indicated in the raisecomOpticalParamAlarmStatus object ..
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 5 }
raisecomOpticalTransceiverParamLowWarningThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by raisecomOpticalParameterValue goes from above the value
of this object to below the value of this
object, or if the initial value of raisecomOpticalParameterValue
object is lower than the value of this object. For
network elements in the status
indications, this threshold violation will be indicated in the
raisecomOpticalParamAlarmStatus object .
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 6 }
raisecomOpticalTransceiverParamAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
normal(1),
high-alarm(2),
high-warning(3),
low-alarm(4),
low-warning(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to indicate the current status of
the thresholds for the monitored optical parameter
on the interface.
If a threshold is currently being exceeded on the
interface, the object will be set. Otherwise,
the object will be set to 1.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 7 }
raisecomOpticalTransceiverParamAlarmLastValue OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the optical parameter value at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
If no threshold value is currently being
exceeded, then the value '-1000000' is returned.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 8 }
raisecomOpticalTransceiverParamAlarmLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the value of sysUpTime at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 9 }
raisecomOpticalTransceiverDDM15MinValidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 15 minute
intervals for which valid performance monitoring data
has been stored on the interface.
The value of this object will be n (where n is the maximum
number of 15 minute intervals supported at this interface),
unless the measurement was (re-)started within the last
(nx15) minutes, in which case the value will be the
number of previous 15 minute intervals for which the agent
has some data.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 10 }
raisecomOpticalTransceiverDDM24HrValidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 24 hour intervals
for which valid performance monitoring data has been stored
on the interface. The max value of this object is 7, it
means that the user can look up 7days history information.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 11 }
raisecomOpticalTransceiverDDMValidStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
valid(1),
invalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the parameter row is valid or invalid.
The object value is 'valide' when the module is present and
supporting digitaldiagnotic. The object value is 'invalid'
when the module is absent, or when the module is present and
not supporting digitaldiagnotic.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverDDMEntry 12 }
-- raisecomOpticalTransceiverPMCurrent Table
raisecomOpticalTransceiverPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomOpticalTransceiverPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains performance monitoring data for the
various optical parameters, collected over the current 15
minute or the current 24 hour interval."
::={ raisecomOpticalTransceiverPMGroup 1 }
raisecomOpticalTransceiverPMCurrentEntry OBJECT-TYPE
SYNTAX RaisecomOpticalTransceiverPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the raisecomOpticalTransceiverPMCurrentTable. It contains
performance monitoring data for a monitored optical
parameter at an interface, collected over the current 15
minute or the current 24 hour interval.
"
INDEX { ifIndex,
raisecomOpticalTransceiverPMCurrentPeriod,
raisecomOpticalTransceiverPMCurrentParamType }
::={ raisecomOpticalTransceiverPMCurrentTable 1 }
RaisecomOpticalTransceiverPMCurrentEntry ::= SEQUENCE {
raisecomOpticalTransceiverPMCurrentPeriod OpticalPMPeriod,
raisecomOpticalTransceiverPMCurrentParamType OpticalParameterType,
raisecomOpticalTransceiverPMCurrentMaxParam OpticalParameterValue,
raisecomOpticalTransceiverPMCurrentMinParam OpticalParameterValue,
raisecomOpticalTransceiverPMCurrentMeanParam OpticalParameterValue
}
raisecomOpticalTransceiverPMCurrentPeriod OBJECT-TYPE
SYNTAX OpticalPMPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates whether the optical parameter values
given in this entry are collected over the current 15 minute or
the current 24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMCurrentEntry 1 }
raisecomOpticalTransceiverPMCurrentParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored, in this entry.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMCurrentEntry 2 }
raisecomOpticalTransceiverPMCurrentMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMCurrentEntry 3 }
raisecomOpticalTransceiverPMCurrentMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMCurrentEntry 4 }
raisecomOpticalTransceiverPMCurrentMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMCurrentEntry 5 }
-- raisecomOpticalTransceiverPMInterval Table
raisecomOpticalTransceiverPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomOpticalTransceiverPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores performance monitoring data for the
various optical parameters, collected over previous
intervals.
This table can have entries for one complete 24 hour
interval and up to 96 complete 15 minute
intervals. A system is required to store at least
4 completed 15 minute intervals. The number of valid
15 minute intervals in this table is indicated by the
raisecomOpticalTransceiverDDM15MinValidIntervals object
and the number of valid 24 hour intervals is indicated by the
raisecomOpticalTransceiverDDM24HrValidIntervals object.
when the optical module is removed from the device, the relative
history records will be cleaned.
"
::={ raisecomOpticalTransceiverPMGroup 2 }
raisecomOpticalTransceiverPMIntervalEntry OBJECT-TYPE
SYNTAX RaisecomOpticalTransceiverPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the raisecomOpticalTransceiverPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
"
INDEX { ifIndex,
raisecomOpticalTransceiverPMIntervalPeriod,
raisecomOpticalTransceiverPMIntervalNumber,
raisecomOpticalTransceiverPMIntervalParamType }
::={ raisecomOpticalTransceiverPMIntervalTable 1 }
RaisecomOpticalTransceiverPMIntervalEntry ::= SEQUENCE {
raisecomOpticalTransceiverPMIntervalPeriod OpticalPMPeriod,
raisecomOpticalTransceiverPMIntervalNumber Integer32,
raisecomOpticalTransceiverPMIntervalParamType OpticalParameterType,
raisecomOpticalTransceiverPMIntervalMaxParam OpticalParameterValue,
raisecomOpticalTransceiverPMIntervalMinParam OpticalParameterValue,
raisecomOpticalTransceiverPMIntervalMeanParam OpticalParameterValue
}
raisecomOpticalTransceiverPMIntervalPeriod OBJECT-TYPE
SYNTAX OpticalPMPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates whether the optical parameter values,
given in this entry, are collected over a period of 15 minutes
or 24 hours.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 1 }
raisecomOpticalTransceiverPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the most recently
completed 15 minute or 24 hour interval, and the interval
identified by N is the interval immediately preceding the one
identified by N-1.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 2 }
raisecomOpticalTransceiverPMIntervalParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored, in this entry.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 3 }
raisecomOpticalTransceiverPMIntervalMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 4 }
raisecomOpticalTransceiverPMIntervalMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 5 }
raisecomOpticalTransceiverPMIntervalMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverPMIntervalEntry 6 }
-- raisecomOpticalTransceiverCurrentStatus Table
raisecomOpticalTransceiverCurrentStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RaisecomOpticalTransceiverCurrentStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores the hard ware information and the information
set by user of the transceiver.
This object belongs to xfp/sfp.
"
::={ raisecomOpticalTransceiverStatusGroup 1 }
raisecomOpticalTransceiverCurrentStatusEntry OBJECT-TYPE
SYNTAX RaisecomOpticalTransceiverCurrentStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the raisecomOpticalTransceiverCurrentStatusTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
This object belongs to xfp/sfp.
"
INDEX { ifIndex }
::={ raisecomOpticalTransceiverCurrentStatusTable 1 }
RaisecomOpticalTransceiverCurrentStatusEntry ::= SEQUENCE {
raisecomOpticalTransceiverHwInfoAbsStatus INTEGER,
raisecomOpticalTransceiverHwInfoNRStatus INTEGER,
raisecomOpticalTransceiverHwInfoRxLosStatus INTEGER,
raisecomOpticalTransceiverHwInfoStandby INTEGER,
raisecomOpticalTransceiverHwInfoLaser INTEGER,
raisecomOpticalTransceiverWaveLengthError Integer32,
raisecomOpticalTransceiverUserWaveLength Integer32,
raisecomOpticalTransceiverUserDataRate INTEGER,
raisecomOpticalTransceiverUserLineLoopBack INTEGER,
raisecomOpticalTransceiverUserXFILoopBack INTEGER,
raisecomOpticalTransceiverPortNotifyEnable EnableVar,
raisecomOpticalTransceiverPortDDMEnable EnableVar,
raisecomOpticalTransceiverPortCheckPwdEnable EnableVar,
raisecomOpticalTransceiverTxFaultCount Integer32,
raisecomOpticalTransceiverTxFaultCountClear ClearVar,
raisecomOpticalTransceiverSpecificationCheckStatus INTEGER,
raisecomOpticalTransceiverTxFaultStatus INTEGER
}
raisecomOpticalTransceiverHwInfoAbsStatus OBJECT-TYPE
SYNTAX INTEGER
{
absent(1),
present(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module is absent
present,absent.
This object belongs to xfp and sfp."
::={ raisecomOpticalTransceiverCurrentStatusEntry 1 }
raisecomOpticalTransceiverHwInfoNRStatus OBJECT-TYPE
SYNTAX INTEGER
{
ready(1),
notready(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module is ready for operation.
ready,notready.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 2 }
raisecomOpticalTransceiverHwInfoRxLosStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
loss(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module operation losses the receiving signal
normal,loss.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 3 }
raisecomOpticalTransceiverHwInfoStandby OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
standby(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the optical module works under standby mode.
normal,standby.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 4 }
raisecomOpticalTransceiverHwInfoLaser OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the optical module laser is turned on
on,off.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 5 }
raisecomOpticalTransceiverWaveLengthError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies error between the actual wavelength
and the wavelength set by the user,measured in pm.
This object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.001.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 6 }
raisecomOpticalTransceiverUserWaveLength OBJECT-TYPE
SYNTAX Integer32(0..3276800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the wavelength value of the optical module set by user,measured in pm.
This object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 7 }
raisecomOpticalTransceiverUserDataRate OBJECT-TYPE
SYNTAX INTEGER(9500..12500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the data rate of the optical module set by user,measured in Mbps.
This object belongs to xfp.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 8 }
raisecomOpticalTransceiverUserLineLoopBack OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
lineLoopback(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the sideline loop-back is tuned on ,
user can change the loop back mode through the object.
normal,lineLoopback.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 9 }
raisecomOpticalTransceiverUserXFILoopBack OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
xfiLoopback(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the XFI loop-back is tuned on
user can change the loop back mode through the object.
normal,xfiLoopback.
This object belongs to xfp.
"
::={ raisecomOpticalTransceiverCurrentStatusEntry 10 }
raisecomOpticalTransceiverPortNotifyEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the generation of a port notifications,
enable or disable.
This object belongs to xfp and sfp.
"
DEFVAL { enable}
::={ raisecomOpticalTransceiverCurrentStatusEntry 11 }
raisecomOpticalTransceiverPortDDMEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of digitaldiagnotic on a port,
enable or disable.
This object belongs to xfp and sfp.
"
DEFVAL { enable}
::={ raisecomOpticalTransceiverCurrentStatusEntry 12 }
raisecomOpticalTransceiverPortCheckPwdEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of password checking on a port,
enable or disable.
This object belongs to xfp.
"
DEFVAL { enable}
::={ raisecomOpticalTransceiverCurrentStatusEntry 13 }
raisecomOpticalTransceiverTxFaultCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of tx-fault signals."
::={ raisecomOpticalTransceiverCurrentStatusEntry 14 }
raisecomOpticalTransceiverTxFaultCountClear OBJECT-TYPE
SYNTAX ClearVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies clear the statistcs of tx-fault signals."
::={ raisecomOpticalTransceiverCurrentStatusEntry 15 }
raisecomOpticalTransceiverSpecificationCheckStatus OBJECT-TYPE
SYNTAX INTEGER{none(0),accord(1),not-accord(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the check status, accord(0)specifies
the optical module accord with industrial. not-accord(2)
specifies the optical module not accord with industrial."
::={ raisecomOpticalTransceiverCurrentStatusEntry 16 }
raisecomOpticalTransceiverTxFaultStatus OBJECT-TYPE
SYNTAX INTEGER{normal(1),tx-fault(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the tx-fault status."
::={ raisecomOpticalTransceiverCurrentStatusEntry 17 }
-- Notifications
raisecomOpticalTransceiverNotifications OBJECT IDENTIFIER ::=
{ raisecomOpticalTransceiver 3 }
raisecomOpticalTransceiverAbsentTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverHwInfoAbsStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module is removed from the device.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 1 }
raisecomOpticalTransceiverPresentTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverHwInfoAbsStatus,
raisecomOpticalTransceiverSpecificationCheckStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module is plugged into the device.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 2 }
raisecomOpticalTransceiverNRAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverHwInfoNRStatus }
STATUS current
DESCRIPTION
"This notification is sent when the transmitted or received data of optical module is invalid.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 3 }
raisecomOpticalTransceiverNRNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverHwInfoNRStatus }
STATUS current
DESCRIPTION
"This notification is sent when the transmitted or received data of optical module is valid.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 4 }
raisecomOpticalTransceiverRxLosAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverHwInfoRxLosStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module receiving signal is lost.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 5 }
raisecomOpticalTransceiverRxLosNormaTrap NOTIFICATION-TYPE
OBJECTS {raisecomOpticalTransceiverHwInfoRxLosStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module receiving signal is back to normal.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 6 }
raisecomOpticalTransceiverCheckPwdFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification is sent when the optical module password checking is failed.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 7 }
raisecomOpticalTransceiverCheckPwdSucceedTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 8 }
raisecomOpticalTransceiverParamAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 9 }
raisecomOpticalTransceiverParamAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 10 }
raisecomOpticalTransceiverParamWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 11 }
raisecomOpticalTransceiverParamWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 12 }
raisecomOpticalTransceiverLaserBackLightAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 13 }
raisecomOpticalTransceiverLaserBackLightAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 14 }
raisecomOpticalTransceiverLaserLifeAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 15 }
raisecomOpticalTransceiverLaserLifeAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 16 }
raisecomOpticalTransceiverParamLowAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 17 }
raisecomOpticalTransceiverParamLowAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 18 }
raisecomOpticalTransceiverParamLowWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 19 }
raisecomOpticalTransceiverParamLowWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverNotifications 20 }
-- Parameters and Notifications
raisecomOpticalTransceiverParamNotifications OBJECT IDENTIFIER ::=
{ raisecomOpticalTransceiver 4 }
raisecomOpticalTransceiverTemperatureAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 1 }
raisecomOpticalTransceiverTemperatureAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 2 }
raisecomOpticalTransceiverTemperatureWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 3 }
raisecomOpticalTransceiverTemperatureWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 4 }
raisecomOpticalTransceiverTxbiasCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx bias Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 5 }
raisecomOpticalTransceiverTxbiasCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx bias Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 6 }
raisecomOpticalTransceiverTxbiasCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx bias Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 7 }
raisecomOpticalTransceiverTxbiasCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx bias Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 8 }
raisecomOpticalTransceiverTxPowerAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx Power value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 9 }
raisecomOpticalTransceiverTxPowerAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 10 }
raisecomOpticalTransceiverTxPowerWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 11 }
raisecomOpticalTransceiverTxPowerWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Tx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 12 }
raisecomOpticalTransceiverRxPowerAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Rx Power value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 13 }
raisecomOpticalTransceiverRxPowerWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Rx Power value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 14 }
raisecomOpticalTransceiverRxPowerWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Rx Power value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 15 }
raisecomOpticalTransceiverRxPowerAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Rx Power value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 16 }
raisecomOpticalTransceiverLaserTemperatureAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Laser Temperature value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 17 }
raisecomOpticalTransceiverLaserTemperatureWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Laser Temperature value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 18 }
raisecomOpticalTransceiverLaserTemperatureWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Laser Temperature value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 19 }
raisecomOpticalTransceiverLaserTemperatureAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module Laser Temperature value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 20 }
raisecomOpticalTransceiverP5V0supplyVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 21 }
raisecomOpticalTransceiverP5V0supplyVoltageWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 22 }
raisecomOpticalTransceiverP5V0supplyVoltageWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 23 }
raisecomOpticalTransceiverP5V0supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 24 }
raisecomOpticalTransceiverP3V3supplyVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 25 }
raisecomOpticalTransceiverP3V3supplyVoltageWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 26 }
raisecomOpticalTransceiverP3V3supplyVoltageWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 27 }
raisecomOpticalTransceiverP3V3supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 28 }
raisecomOpticalTransceiverP1V8supplyVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 29 }
raisecomOpticalTransceiverP1V8supplyVoltageWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 30 }
raisecomOpticalTransceiverP1V8supplyVoltageWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 31 }
raisecomOpticalTransceiverP1V8supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 32 }
raisecomOpticalTransceiverN5V2supplyVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 33 }
raisecomOpticalTransceiverN5V2supplyVoltageWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2v supply Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 34 }
raisecomOpticalTransceiverN5V2supplyVoltageWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 35 }
raisecomOpticalTransceiverN5V2supplyVoltageAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2v supply Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 36 }
raisecomOpticalTransceiverApdBiasVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module APD Bias Voltage value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 37 }
raisecomOpticalTransceiverApdBiasVoltageWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module APD Bias Voltage value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 38 }
raisecomOpticalTransceiverApdBiasVoltageWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 39 }
raisecomOpticalTransceiverApdBiasVoltageAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module APD Bias Voltage value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 40 }
raisecomOpticalTransceiverP5V0supplyCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 41 }
raisecomOpticalTransceiverP5V0supplyCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 42 }
raisecomOpticalTransceiverP5V0supplyCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 43 }
raisecomOpticalTransceiverP5V0supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +5.0V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 44 }
raisecomOpticalTransceiverP3V3supplyCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 45 }
raisecomOpticalTransceiverP3V3supplyCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 46 }
raisecomOpticalTransceiverP3V3supplyCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 47 }
raisecomOpticalTransceiverP3V3supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +3.3V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 48 }
raisecomOpticalTransceiverP1V8supplyCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 49 }
raisecomOpticalTransceiverP1V8supplyCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 50 }
raisecomOpticalTransceiverP1V8supplyCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 51 }
raisecomOpticalTransceiverP1V8supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module +1.8V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 52 }
raisecomOpticalTransceiverN5V2supplyCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2V supply Current value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 53 }
raisecomOpticalTransceiverN5V2supplyCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2V supply Current value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 54 }
raisecomOpticalTransceiverN5V2supplyCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 55 }
raisecomOpticalTransceiverN5V2supplyCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module -5.2V supply Current value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 56 }
raisecomOpticalTransceiverTecCurrentAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module TecCurrent value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 57 }
raisecomOpticalTransceiverTecCurrentWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module TecCurrent value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 58 }
raisecomOpticalTransceiverTecCurrentWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module TecCurrent value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 59 }
raisecomOpticalTransceiverTecCurrentAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module TecCurrent value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 60 }
raisecomOpticalTransceiverLaserWavelengthAlarmTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module laserWavelength value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 61 }
raisecomOpticalTransceiverLaserWavelengthWarningTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module laserWavelength value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 62 }
raisecomOpticalTransceiverLaserWavelengthWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module laserWavelength value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 63 }
raisecomOpticalTransceiverLaserWavelengthAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomNotificationLocation,
raisecomOpticalTransceiverParameterValue,
raisecomOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module laserWavelength value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 64 }
raisecomOpticalTransceiverTxFaultTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverTxFaultStatus }
STATUS current
DESCRIPTION
"This notification is sent when the SFP optical module occures Tx-fault signal.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 65 }
raisecomOpticalTransceiverTxNormalTrap NOTIFICATION-TYPE
OBJECTS { raisecomOpticalTransceiverTxFaultStatus }
STATUS current
DESCRIPTION
"This notification is sent when the SFP optical module cancels the Tx-fault signal.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ raisecomOpticalTransceiverParamNotifications 66 }
END