-- RITTAL GmbH & Co. KG, Herborn
|
|
-- CMC-TC-MIB Version 1.1h
|
|
-- CMC-TC - DK7320.100
|
|
--
|
|
-- Management Information Base for SNMP Network Management
|
|
--
|
|
-- Copyright 2002 - 2007 Rittal Herborn.
|
|
-- All Rights Reserved.
|
|
--
|
|
-- The information in this document is subject to change without notice.
|
|
-- Refer to document "AGB_Software_Rittal.pdf"
|
|
--
|
|
--*********************************************************************
|
|
-- Release History
|
|
-- Date: October 17, 2002 (Version 1.0)
|
|
-- Revised by MHain
|
|
-- Date: April 1, 2003 (Version 1.1)
|
|
-- Added: unitXMsgQuit, cmcTcControl, Sensor types, Output types, Unit types
|
|
-- Date: November 3, 2003 (Version 1.1a)
|
|
-- Added: new sensors, new outputs (FCS, RTT)
|
|
-- Date: March 11, 2004 (Version 1.1b)
|
|
-- Added: new sensors, new outputs, new messages (RCT, PSM)
|
|
-- Date: Jan 11, 2006 (Version 1.1c)
|
|
-- Changed: sysName... FROM RFC1213-MIB, seperate lines, for HP SIM
|
|
-- Date: Jan 24, 2006 (Version 1.1d)
|
|
-- Added: new unit type (ActivePSM8)
|
|
-- Added: new output type (power output 16/20A)
|
|
-- Date: Dec 5, 2006 (Version 1.1e)
|
|
-- Added: sensor/output types MeteredPSM, LCP
|
|
-- Date: March 8, 2007 (Version 1.1f)
|
|
-- Changed: Output names (RTT, Power Out)
|
|
-- Date: March 22, 2007 (Version 1.1g)
|
|
-- Changed: New sensor units, wireless sensors, timer function SMS
|
|
-- Date: July 23, 2007 (Version 1.1h)
|
|
-- Added: New sensors/outputs LCP
|
|
--*********************************************************************
|
|
|
|
RITTAL-CMC-TC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
sysName FROM RFC1213-MIB
|
|
sysDescr FROM RFC1213-MIB
|
|
sysContact FROM RFC1213-MIB
|
|
sysLocation FROM RFC1213-MIB
|
|
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
rittal OBJECT IDENTIFIER ::= { enterprises 2606 }
|
|
cmcTc OBJECT IDENTIFIER ::= { rittal 4 }
|
|
cmcTcMibRev OBJECT IDENTIFIER ::= { cmcTc 1 }
|
|
cmcTcStatus OBJECT IDENTIFIER ::= { cmcTc 2 }
|
|
cmcTcStatusSensorUnit1 OBJECT IDENTIFIER ::= { cmcTcStatus 3 }
|
|
cmcTcStatusUnit1Sensors OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit1 5 }
|
|
cmcTcStatusUnit1Outputs OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit1 6 }
|
|
cmcTcStatusUnit1Msg OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit1 7 }
|
|
cmcTcStatusSensorUnit2 OBJECT IDENTIFIER ::= { cmcTcStatus 4 }
|
|
cmcTcStatusUnit2Sensors OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit2 5 }
|
|
cmcTcStatusUnit2Outputs OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit2 6 }
|
|
cmcTcStatusUnit2Msg OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit2 7 }
|
|
cmcTcStatusSensorUnit3 OBJECT IDENTIFIER ::= { cmcTcStatus 5 }
|
|
cmcTcStatusUnit3Sensors OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit3 5 }
|
|
cmcTcStatusUnit3Outputs OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit3 6 }
|
|
cmcTcStatusUnit3Msg OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit3 7 }
|
|
cmcTcStatusSensorUnit4 OBJECT IDENTIFIER ::= { cmcTcStatus 6 }
|
|
cmcTcStatusUnit4Sensors OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit4 5 }
|
|
cmcTcStatusUnit4Outputs OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit4 6 }
|
|
cmcTcStatusUnit4Msg OBJECT IDENTIFIER ::= { cmcTcStatusSensorUnit4 7 }
|
|
cmcTcStatusExtUnit OBJECT IDENTIFIER ::= { cmcTcStatus 7 }
|
|
cmcTcSetup OBJECT IDENTIFIER ::= { cmcTc 3 }
|
|
cmcTcSetupGeneral OBJECT IDENTIFIER ::= { cmcTcSetup 1 }
|
|
cmcTcTimerTable1 OBJECT IDENTIFIER ::= { cmcTcSetupGeneral 8 }
|
|
cmcTcTrapControl OBJECT IDENTIFIER ::= { cmcTc 4 }
|
|
cmcTcTraps OBJECT IDENTIFIER ::= { cmcTcTrapControl 7 }
|
|
cmcTcControl OBJECT IDENTIFIER ::= { cmcTc 5 }
|
|
|
|
|
|
--*****************************************************************************
|
|
--CMC-TC ComputerMultiControl-TopConcept DK7320.100
|
|
--*****************************************************************************
|
|
--cmcTcMibRev-group
|
|
|
|
cmcTcMibMajRev OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Major Revision level.
|
|
A change in the major revision level represents a major change
|
|
in the architecture of the MIB. A change in the major revision
|
|
level may indicate a significant change in the information,
|
|
correct interpretation of data may require a MIB document
|
|
with the same major revision level."
|
|
::= { cmcTcMibRev 1 }
|
|
|
|
cmcTcMibMinRev OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Minor Revision level.
|
|
A change in the minor revision level may represent some minor
|
|
additional support, no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cmcTcMibRev 2 }
|
|
|
|
cmcTcMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
ok (2),
|
|
degraded (3),
|
|
failed (4),
|
|
configChanged (5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The overall condition (status) of the system represented by
|
|
this MIB.
|
|
(2) OK
|
|
(3) a minor problem, warning condition (yellow LED on CMC)
|
|
(4) a major problem (red LED on CMC)
|
|
(5) configuration of sensor units changed or
|
|
unit detected (red/yellow/green LED on CMC)"
|
|
::= { cmcTcMibRev 3 }
|
|
|
|
|
|
|
|
--status-group
|
|
cmcTcStatusDeviceCMC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
failed(1),
|
|
ok(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Status of CMC-TC unit itself
|
|
(1) failed
|
|
(2) OK"
|
|
::= { cmcTcStatus 1 }
|
|
|
|
cmcTcUnitsConnected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensor units connected to the CMC, Port 1 to 4"
|
|
::= { cmcTcStatus 2 }
|
|
|
|
|
|
--status sensor units-group
|
|
|
|
--unit 1
|
|
cmcTcUnit1TypeOfDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
unitIO (2),
|
|
unitAccess (3),
|
|
unitClimate (4),
|
|
unitFCS (5),
|
|
unitRTT (6),
|
|
unitRCT (7),
|
|
unitPSM (8),
|
|
unitPSM8 (9),
|
|
unitPSMMetered (10),
|
|
unitIOWireless (11),
|
|
unitPSM6Schuko (12),
|
|
unitPSM6C19 (13)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor unit connected to port 1"
|
|
::= { cmcTcStatusSensorUnit1 1 }
|
|
|
|
cmcTcUnit1Text OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for sensor unit connected to port 1"
|
|
::= { cmcTcStatusSensorUnit1 2 }
|
|
|
|
cmcTcUnit1Serial OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serialnumber of sensor unit connected to port 1"
|
|
::= { cmcTcStatusSensorUnit1 3 }
|
|
|
|
cmcTcUnit1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
error(2),
|
|
changed(3),
|
|
quit(4),
|
|
timeout(5),
|
|
detected(6),
|
|
notAvail(7),
|
|
lowPower(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Status sensor unit connected to port 1
|
|
(1) OK
|
|
(2) error, e. g. value overflow
|
|
(3) configuration of sensor unit has changed, confirmation required
|
|
(4) Quit from sensor unit to confirm configuration changes
|
|
(5) timeout of sensor unit, confirmation required to unload this unit
|
|
(6) sensor unit detected, needs to be confirmed
|
|
(7) unit is not available
|
|
(8) supply voltage is too low"
|
|
::= { cmcTcStatusSensorUnit1 4 }
|
|
|
|
-- Sensors
|
|
cmcTcUnit1NumberOfSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors connected to sensor unit 1"
|
|
::= { cmcTcStatusUnit1Sensors 1 }
|
|
|
|
-- table with entry for each sensor available on this unit
|
|
cmcTcUnit1SensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit1SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of sensor table"
|
|
::= { cmcTcStatusUnit1Sensors 2 }
|
|
|
|
cmcTcUnit1SensorEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit1SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of sensor table"
|
|
INDEX { unit1SensorIndex }
|
|
::= { cmcTcUnit1SensorTable 1 }
|
|
|
|
CmcTcUnit1SensorEntry ::=
|
|
SEQUENCE {
|
|
unit1SensorIndex
|
|
INTEGER,
|
|
unit1SensorType
|
|
INTEGER,
|
|
unit1SensorText
|
|
DisplayString,
|
|
unit1SensorStatus
|
|
INTEGER,
|
|
unit1SensorValue
|
|
INTEGER,
|
|
unit1SensorSetHigh
|
|
INTEGER,
|
|
unit1SensorSetLow
|
|
INTEGER,
|
|
unit1SensorSetWarn
|
|
INTEGER
|
|
}
|
|
|
|
unit1SensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of value entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit1NumberOfSensors."
|
|
::= { cmcTcUnit1SensorEntry 1 }
|
|
|
|
unit1SensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
access (4),
|
|
vibration (5),
|
|
motion (6),
|
|
smoke (7),
|
|
airFlow (8),
|
|
type6 (9),
|
|
temperature(10),
|
|
current4to20(11),
|
|
humidity(12),
|
|
userNO (13),
|
|
userNC (14),
|
|
lock (15),
|
|
unlock (16),
|
|
voltOK (17),
|
|
voltage (18),
|
|
fanOK (19),
|
|
readerKeypad (20),
|
|
dutyPWM (21),
|
|
fanStatus (22),
|
|
leakage (23),
|
|
warningRTT (24),
|
|
alarmRTT (25),
|
|
filterRTT (26),
|
|
heatflowRCT (27),
|
|
alarmRCT (28),
|
|
warningRCT (29),
|
|
currentPSM (30),
|
|
statusPSM (31),
|
|
positionPSM (32),
|
|
airFlap (33),
|
|
acoustic (34),
|
|
detACfault (35),
|
|
detACfirstAlarm (36),
|
|
detACmainAlarm (37),
|
|
rpm11LCP (40),
|
|
rpm12LCP (41),
|
|
rpm21LCP (42),
|
|
rpm22LCP (43),
|
|
rpm31LCP (44),
|
|
rpm32LCP (45),
|
|
rpm41LCP (46),
|
|
rpm42LCP (47),
|
|
airTemp11LCP (48),
|
|
airTemp12LCP (49),
|
|
airTemp21LCP (50),
|
|
airTemp22LCP (51),
|
|
airTemp31LCP (52),
|
|
airTemp32LCP (53),
|
|
airTemp41LCP (54),
|
|
airTemp42LCP (55),
|
|
temp1LCP (56),
|
|
temp2LCP (57),
|
|
waterInTemp (58),
|
|
waterOutTemp (59),
|
|
waterFlow (60),
|
|
fanSpeed (61),
|
|
valve (62),
|
|
statusLCP (63),
|
|
waterDelta (64),
|
|
valveActual (65),
|
|
contrTemp2 (66),
|
|
condensateDuration (67),
|
|
condensateCycles (68),
|
|
totalKWhPSM (72),
|
|
totalKWPSM (73),
|
|
frequencyPSM (74),
|
|
voltagePSM (75),
|
|
voltStatusPSM (76),
|
|
amperePSM (77),
|
|
ampStatusPSM (78),
|
|
kWPSM (79),
|
|
kWhPSM (80),
|
|
kWhTempPSM (81),
|
|
temperatureWL (100),
|
|
temperature1WL (101),
|
|
humidityWL (102),
|
|
accessWL (103),
|
|
userNOWL (104),
|
|
userNCWL (105),
|
|
analogWL (106)
|
|
}
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor which is connected to sensor unit 1 to sensor[unit1SensorIndex]
|
|
1: no sensor connected
|
|
2: sensor failure
|
|
3: value overflow
|
|
4: sensor type 1, access sensor
|
|
5: sensor type 2, vibration sensor
|
|
6: sensor type 3, motion sensor
|
|
7: sensor type 4, smoke sensor
|
|
8: sensor type 5, air flow sensor
|
|
9: sensor type 6, reserved
|
|
10: sensor type 7, temperature sensor
|
|
11: sensor type 8, 4..20mA sensor
|
|
12: sensor type 9, humidity sensor
|
|
13: user sensor with normally opened contact
|
|
14: user sensor with normally closed contact
|
|
15: door locked sensor from locking device
|
|
16: remote unlock sensor (e.g. external keypad)
|
|
17: voltage sensor, indicates status of main voltage (OK, NOK)
|
|
18: voltage value
|
|
19: fan status, from CMC-TC-FAS-Unit
|
|
20: cardreader or keypad, connected to I2C port
|
|
21: duty cycle of fan, FCS-Unit
|
|
22: status of fan, FCS-Unit
|
|
23: leakage sensor
|
|
24: warning, RittalTopTherm(RTT)-Unit
|
|
25: alarm, RittalTopTherm-Unit
|
|
26: temperature difference filter monitor, RTT-Unit
|
|
27: heatflow RCT-Unit
|
|
28: alarm RCT-Unit
|
|
29: warning RCT-Unit
|
|
30: actual current*10, PSM-Unit
|
|
31: status PSM-Unit
|
|
32: position PSM-Unit, normal/reversed = circuit 1/2
|
|
33: air Flap
|
|
34: acoustic sensor
|
|
35: DET-AC fault (extinguisher)
|
|
36: DET-AC first alarm (extinguisher)
|
|
37: DET-AC main alarm (extinguisher)
|
|
40-47: RPM Fan 1.1 - Fan 4.2, LCP
|
|
48-55: Air temperature 1.1 - 4.2, LCP
|
|
56,57: actual temperature 1,2, LCP
|
|
58: water inlet temperature, LCP
|
|
59: water outlet temperature, LCP
|
|
60: water flow
|
|
61: fan speed (desired value)
|
|
62: status valve, LCP
|
|
63: status LCP
|
|
64: temperature difference water temperatures
|
|
65: control temperature 1, LCP
|
|
66: control temperature 2, LCP
|
|
67: condensate pump, duration, LCP
|
|
68: condensate pump, cycles, LCP
|
|
72: total energy*10 (kWh), PSM
|
|
73: total power*10 (kW), PSM
|
|
74: frequency*10 (Hz), PSM
|
|
75: voltage*10 (V), PSM
|
|
76: voltage status, PSM
|
|
77: current*10 (A), PSM
|
|
78: current status, PSM
|
|
79: power*10 (kW) per phase, PSM
|
|
80: energy*10 (kWh) per phase, PSM
|
|
81: temporary energy*10 (kWh) per phase, PSM
|
|
100: temperature sensor, wireless
|
|
101: temperature sensor (combi), wireless
|
|
102: humidity sensor, wireless
|
|
103: access sensor, wireless
|
|
104: user sensor with normally opened contact, wireless
|
|
105: user sensor with normally closed contact, wireless
|
|
106: analog sensor 4..20mA, wireless"
|
|
::= { cmcTcUnit1SensorEntry 2 }
|
|
|
|
unit1SensorText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each sensor (entry in the table)"
|
|
::= { cmcTcUnit1SensorEntry 3 }
|
|
|
|
unit1SensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
warning(7),
|
|
tooLow(8),
|
|
tooHigh(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the sensor"
|
|
::= { cmcTcUnit1SensorEntry 4 }
|
|
|
|
unit1SensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { cmcTcUnit1SensorEntry 5 }
|
|
|
|
unit1SensorSetHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for high setpoint of sensor"
|
|
::= { cmcTcUnit1SensorEntry 6 }
|
|
|
|
unit1SensorSetLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for low setpoint of sensor,
|
|
also used as alarm delay"
|
|
::= { cmcTcUnit1SensorEntry 7 }
|
|
|
|
unit1SensorSetWarn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for warning setpoint of sensor,
|
|
also used as fan threshold"
|
|
::= { cmcTcUnit1SensorEntry 8 }
|
|
|
|
|
|
-- table END
|
|
|
|
-- Outputs
|
|
cmcTcUnit1NumberOfOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outputs available on sensor unit 1"
|
|
::= { cmcTcStatusUnit1Outputs 1 }
|
|
|
|
-- table with entry for each output available on this unit
|
|
|
|
cmcTcUnit1OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit1OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of output table"
|
|
::= { cmcTcStatusUnit1Outputs 2 }
|
|
|
|
cmcTcUnit1OutputEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit1OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of output table"
|
|
INDEX { unit1OutputIndex }
|
|
::= { cmcTcUnit1OutputTable 1 }
|
|
|
|
CmcTcUnit1OutputEntry ::=
|
|
SEQUENCE {
|
|
unit1OutputIndex
|
|
INTEGER,
|
|
unit1OutputType
|
|
INTEGER,
|
|
unit1OutputText
|
|
DisplayString,
|
|
unit1OutputStatus
|
|
INTEGER,
|
|
unit1OutputValue
|
|
INTEGER,
|
|
unit1OutputSet
|
|
INTEGER,
|
|
unit1OutputConfig
|
|
INTEGER,
|
|
unit1OutputDelay
|
|
INTEGER,
|
|
unit1OutputTimeoutAction
|
|
INTEGER
|
|
}
|
|
|
|
unit1OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of output entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit1NumberOfOutputs."
|
|
::= { cmcTcUnit1OutputEntry 1 }
|
|
|
|
unit1OutputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
doorLock (4),
|
|
univLock1 (5),
|
|
univLock2 (6),
|
|
fan (7),
|
|
fanSpeedContr (8),
|
|
universalOut (9),
|
|
roomLock(10),
|
|
powerOut(11),
|
|
doorLockMaster(12),
|
|
doorLockFRi (13),
|
|
setpoint (14),
|
|
setpointTimax (15),
|
|
hysteresisRCT (16),
|
|
commandRCT (17),
|
|
relayPSM (18),
|
|
setHighPSM (19),
|
|
setLowPSM (20),
|
|
setpointRTT (21),
|
|
setTimaxRTT (22),
|
|
powerOut1(23),
|
|
controlModeLCP (30),
|
|
minFanSpeedLCP (31),
|
|
minDeltaTLCP (32),
|
|
maxDeltaTLCP (33),
|
|
kPLCP (34),
|
|
kILCP (35),
|
|
kDLCP (36),
|
|
flowRateLCP(37),
|
|
cwValueLCP (38),
|
|
deltaTLCP (39),
|
|
ctrModLCP (40),
|
|
voltHighPSM (42),
|
|
voltLowPSM (43),
|
|
ampHighPSM (44),
|
|
ampLowPSM (45),
|
|
commandPSM (46)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of output which is connected to sensor unit 1 to output[unit1OutputIndex]
|
|
1: no output connected
|
|
2: output failure
|
|
3: value overflow
|
|
4: output type 1, door locking TS8,Ergoform
|
|
5: output type 2, universal lock 1, lock with power
|
|
6: output type 3, universal lock 2, unlock with power
|
|
7: output type 4, fan relay
|
|
8: output type 5, fan controlled
|
|
9: output type 6, universal relay output
|
|
10: output type 7, room door lock
|
|
11: output type 8, power output
|
|
12: output type 9, door lock with Master key
|
|
13: output type 10, door lock FR(i)
|
|
14: setpoint (FCS, LCP)
|
|
15: setpoint temperature monitoring (LCP)
|
|
16: hysteresis of setpoint (LCP)
|
|
17: command for remote control of RCT
|
|
18: relay PSM, 1=On, 0=Off
|
|
19: high setpoint current monitoring PSM
|
|
20: low setpoint current monitoring PSM
|
|
21: setpoint temperature RTT
|
|
22: setpoint temperature monitoring RTT
|
|
23: power output 20A
|
|
30: control mode, LCP
|
|
31: min fan speed (fan control), LCP
|
|
32: min delta T (fan control), LCP
|
|
33: max delta T (fan control), LCP
|
|
34: PID controller, KP, LCP
|
|
35: PID controller, KI, LCP
|
|
36 PID controller, KD, LCP
|
|
37 flowrate flowmeter, LCP
|
|
38: cw value of water (default: 4187), LCP
|
|
39: deltaT, LCP
|
|
40: control mode, LCP
|
|
42: setpoint high voltage PSM
|
|
43: setpoint low voltage PSM
|
|
44: setpoint high current PSM
|
|
45: setpoint low current PSM
|
|
46: command PSM"
|
|
::= { cmcTcUnit1OutputEntry 2 }
|
|
|
|
|
|
unit1OutputText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each output (entry in the table)"
|
|
::= { cmcTcUnit1OutputEntry 3 }
|
|
|
|
unit1OutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
setOff(7),
|
|
setOn(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the output"
|
|
::= { cmcTcUnit1OutputEntry 4 }
|
|
|
|
unit1OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for output"
|
|
::= { cmcTcUnit1OutputEntry 5 }
|
|
|
|
unit1OutputSet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2),
|
|
lock (3),
|
|
unlock (4),
|
|
unlockDelay (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command for output"
|
|
::= { cmcTcUnit1OutputEntry 6 }
|
|
|
|
unit1OutputConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disRemote (1),
|
|
enRemote (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration for output
|
|
1: disable remote control (e.g. keypad)
|
|
2: enable remote control "
|
|
::= { cmcTcUnit1OutputEntry 7 }
|
|
|
|
unit1OutputDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unsigned Value for delay,
|
|
after this time the output will fall into the previous state"
|
|
::= { cmcTcUnit1OutputEntry 8 }
|
|
|
|
unit1OutputTimeoutAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stay (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State for output if timeout (RS422) occurs"
|
|
::= { cmcTcUnit1OutputEntry 9 }
|
|
|
|
|
|
-- Messages
|
|
|
|
cmcTcUnit1NumberOfMsgs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of messages that can be created with sensor unit 1"
|
|
::= { cmcTcStatusUnit1Msg 1 }
|
|
|
|
-- table with entry for each alarm available on this unit
|
|
|
|
cmcTcUnit1MsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit1MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of message table"
|
|
::= { cmcTcStatusUnit1Msg 2 }
|
|
|
|
cmcTcUnit1MsgEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit1MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of message table"
|
|
INDEX { unit1MsgIndex }
|
|
::= { cmcTcUnit1MsgTable 1 }
|
|
|
|
CmcTcUnit1MsgEntry ::=
|
|
SEQUENCE {
|
|
unit1MsgIndex
|
|
INTEGER,
|
|
unit1MsgText
|
|
DisplayString,
|
|
unit1MsgStatus
|
|
INTEGER,
|
|
unit1MsgRelay
|
|
INTEGER,
|
|
unit1MsgBeeper
|
|
INTEGER,
|
|
unit1MsgTrap1
|
|
INTEGER,
|
|
unit1MsgTrap2
|
|
INTEGER,
|
|
unit1MsgTrap3
|
|
INTEGER,
|
|
unit1MsgTrap4
|
|
INTEGER,
|
|
unit1MsgQuit
|
|
INTEGER
|
|
}
|
|
|
|
unit1MsgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of message entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit1NumberOfMsgs."
|
|
::= { cmcTcUnit1MsgEntry 1 }
|
|
|
|
unit1MsgText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each message (entry in the table)"
|
|
::= { cmcTcUnit1MsgEntry 2 }
|
|
|
|
unit1MsgStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
configChanged(2),
|
|
error(3),
|
|
ok(4),
|
|
alarm(5),
|
|
warning(6),
|
|
tooLow(7),
|
|
tooHigh(8),
|
|
setOff(9),
|
|
setOn(10),
|
|
open(11),
|
|
closed(12),
|
|
locked(13),
|
|
unlRemote(14),
|
|
unlReaderKeypad(15),
|
|
unlSNMP(16),
|
|
unlWEB(17),
|
|
unlTimer(18),
|
|
noAccess(19),
|
|
circuit1 (20),
|
|
circuit2 (21),
|
|
lowBatt (22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual message status
|
|
1: not available
|
|
2: configuration has changed (sensor new, changed, lost)
|
|
3: error
|
|
4: OK
|
|
5: alarm, e.g. smoke, vibration...
|
|
6: warning of analog value, value reached warning threshold
|
|
7: analog value too low, value reached low threshold
|
|
8: analog value too high, value reached high threshold
|
|
9: output is set to OFF
|
|
10: output is set to ON
|
|
11: door is open
|
|
12: door is closed
|
|
13: door is locked
|
|
14: door is unlocked by remote input, e.g. external cardreader
|
|
15: door is unlocked by reader or keypad connected to I2C
|
|
16: door is unlocked by SNMP set command (unit1OutputSet)
|
|
17: door is unlocked by WEB
|
|
18: door is unlocked by timer
|
|
19: no access, wrong keycode or cardnumber
|
|
20: orientation of PSM-Unit is circuit 1
|
|
21: orientation of PSM-Unit is circuit 2
|
|
22: battery low, wireless sensor"
|
|
::= { cmcTcUnit1MsgEntry 3 }
|
|
|
|
unit1MsgRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm relay for this message/alarm
|
|
1: no switching of alarm relay
|
|
2: switching of alarm relay"
|
|
::= { cmcTcUnit1MsgEntry 4 }
|
|
|
|
unit1MsgBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm beeper for this alarm
|
|
1: no audible alarm
|
|
2: audible alarm"
|
|
::= { cmcTcUnit1MsgEntry 5 }
|
|
|
|
unit1MsgTrap1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 1 activated"
|
|
::= { cmcTcUnit1MsgEntry 6 }
|
|
|
|
unit1MsgTrap2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 2 activated"
|
|
::= { cmcTcUnit1MsgEntry 7 }
|
|
|
|
unit1MsgTrap3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 3 activated"
|
|
::= { cmcTcUnit1MsgEntry 8 }
|
|
|
|
unit1MsgTrap4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 4 and Event Logging activated"
|
|
::= { cmcTcUnit1MsgEntry 9 }
|
|
|
|
unit1MsgQuit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset of this alarm
|
|
1: auto
|
|
2: manual, alarm needs confirmation, e. g. with 'C' key"
|
|
::= { cmcTcUnit1MsgEntry 10 }
|
|
-- table unit 1 END
|
|
|
|
-- unit2
|
|
cmcTcUnit2TypeOfDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
unitIO (2),
|
|
unitAccess (3),
|
|
unitClimate (4),
|
|
unitFCS (5),
|
|
unitRTT (6),
|
|
unitRCT (7),
|
|
unitPSM (8),
|
|
unitPSM8 (9),
|
|
unitPSMMetered (10),
|
|
unitIOWireless (11),
|
|
unitPSM6Schuko (12),
|
|
unitPSM6C19 (13)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor unit connected to port 2"
|
|
::= { cmcTcStatusSensorUnit2 1 }
|
|
|
|
cmcTcUnit2Text OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for sensor unit connected to port 2"
|
|
::= { cmcTcStatusSensorUnit2 2 }
|
|
|
|
cmcTcUnit2Serial OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serialnumber of sensor unit connected to port 2"
|
|
::= { cmcTcStatusSensorUnit2 3 }
|
|
|
|
cmcTcUnit2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
error(2),
|
|
changed(3),
|
|
quit(4),
|
|
timeout(5),
|
|
detected(6),
|
|
notAvail(7),
|
|
lowPower(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Status sensor unit connected to port 2
|
|
(1) OK
|
|
(2) error
|
|
(3) configuration of sensor unit has changed, confirmation required
|
|
(4) Quit from sensor unit to confirm configuration changes
|
|
(5) timeout of sensor unit, confirmation required
|
|
(6) sensor unit detected, needs to be confirmed
|
|
(8) supply voltage is too low"
|
|
::= { cmcTcStatusSensorUnit2 4 }
|
|
|
|
-- unit 2 table
|
|
|
|
-- Sensors
|
|
cmcTcUnit2NumberOfSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors connected to sensor unit 2"
|
|
::= { cmcTcStatusUnit2Sensors 1 }
|
|
|
|
-- table with entry for each sensor available on this unit
|
|
cmcTcUnit2SensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit2SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of sensor table"
|
|
::= { cmcTcStatusUnit2Sensors 2 }
|
|
|
|
cmcTcUnit2SensorEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit2SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of sensor table"
|
|
INDEX { unit2SensorIndex }
|
|
::= { cmcTcUnit2SensorTable 1 }
|
|
|
|
CmcTcUnit2SensorEntry ::=
|
|
SEQUENCE {
|
|
unit2SensorIndex
|
|
INTEGER,
|
|
unit2SensorType
|
|
INTEGER,
|
|
unit2SensorText
|
|
DisplayString,
|
|
unit2SensorStatus
|
|
INTEGER,
|
|
unit2SensorValue
|
|
INTEGER,
|
|
unit2SensorSetHigh
|
|
INTEGER,
|
|
unit2SensorSetLow
|
|
INTEGER,
|
|
unit2SensorSetWarn
|
|
INTEGER
|
|
}
|
|
|
|
unit2SensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of value entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit2NumberOfSensors."
|
|
::= { cmcTcUnit2SensorEntry 1 }
|
|
|
|
unit2SensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
access (4),
|
|
vibration (5),
|
|
motion (6),
|
|
smoke (7),
|
|
airFlow (8),
|
|
type6 (9),
|
|
temperature(10),
|
|
current4to20(11),
|
|
humidity(12),
|
|
userNO (13),
|
|
userNC (14),
|
|
lock (15),
|
|
unlock (16),
|
|
voltOK (17),
|
|
voltage (18),
|
|
fanOK (19),
|
|
readerKeypad (20),
|
|
dutyPWM (21),
|
|
fanStatus (22),
|
|
leakage (23),
|
|
warningRTT (24),
|
|
alarmRTT (25),
|
|
filterRTT (26),
|
|
heatflowRCT (27),
|
|
alarmRCT (28),
|
|
warningRCT (29),
|
|
currentPSM (30),
|
|
statusPSM (31),
|
|
positionPSM (32),
|
|
airFlap (33),
|
|
detACfault (35),
|
|
detACfirstAlarm (36),
|
|
detACmainAlarm (37),
|
|
acoustic (34),
|
|
rpm11LCP (40),
|
|
rpm12LCP (41),
|
|
rpm21LCP (42),
|
|
rpm22LCP (43),
|
|
rpm31LCP (44),
|
|
rpm32LCP (45),
|
|
rpm41LCP (46),
|
|
rpm42LCP (47),
|
|
airTemp11LCP (48),
|
|
airTemp12LCP (49),
|
|
airTemp21LCP (50),
|
|
airTemp22LCP (51),
|
|
airTemp31LCP (52),
|
|
airTemp32LCP (53),
|
|
airTemp41LCP (54),
|
|
airTemp42LCP (55),
|
|
temp1LCP (56),
|
|
temp2LCP (57),
|
|
waterInTemp (58),
|
|
waterOutTemp (59),
|
|
waterFlow (60),
|
|
fanSpeed (61),
|
|
valve (62),
|
|
statusLCP (63),
|
|
waterDelta (64),
|
|
valveActual (65),
|
|
contrTemp2 (66),
|
|
condensateDuration (67),
|
|
condensateCycles (68),
|
|
totalKWhPSM (72),
|
|
totalKWPSM (73),
|
|
frequencyPSM (74),
|
|
voltagePSM (75),
|
|
voltStatusPSM (76),
|
|
amperePSM (77),
|
|
ampStatusPSM (78),
|
|
kWPSM (79),
|
|
kWhPSM (80),
|
|
kWhTempPSM (81),
|
|
temperatureWL (100),
|
|
temperature1WL (101),
|
|
humidityWL (102),
|
|
accessWL (103),
|
|
userNOWL (104),
|
|
userNCWL (105),
|
|
analogWL (106)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor which is connected to sensor unit 2 to sensor[unit2SensorIndex]
|
|
1: no sensor connected
|
|
2: sensor failure
|
|
3: value overflow
|
|
4: sensor type 1, access sensor
|
|
5: sensor type 2, vibration sensor
|
|
6: sensor type 3, motion sensor
|
|
7: sensor type 4, smoke sensor
|
|
8: sensor type 5, air flow sensor
|
|
9: sensor type 6, reserved
|
|
10: sensor type 7, temperature sensor
|
|
11: sensor type 8, 4..20mA sensor
|
|
12: sensor type 9, humidity sensor
|
|
13: user sensor with normally opened contact
|
|
14: user sensor with normally closed contact
|
|
15: door locked sensor from locking device
|
|
16: remote unlock sensor (e.g. external keypad)
|
|
17: voltage sensor, indicates status of main voltage
|
|
18: voltage value
|
|
19: fan status
|
|
20: cardreader or keypad, connected to I2C port
|
|
21: duty cycle of fan, FCS-Unit
|
|
22: status of fan, FCS-Unit
|
|
23: leakage sensor
|
|
24: warning, RittalTopTherm(RTT)-Unit
|
|
25: alarm, RittalTopTherm-Unit
|
|
26: temperature difference filter monitor, RTT-Unit
|
|
27: heatflow RCT-Unit
|
|
28: alarm RCT-Unit
|
|
29: warning RCT-Unit
|
|
30: actual current*10, PSM-Unit
|
|
31: status PSM-Unit
|
|
32: position PSM-Unit, normal/reversed = circuit 1/2
|
|
33: air Flap
|
|
34: acoustic sensor
|
|
35: DET-AC fault (extinguisher)
|
|
36: DET-AC first alarm (extinguisher)
|
|
37: DET-AC main alarm (extinguisher)
|
|
40-47: RPM Fan 1.1 - Fan 4.2, LCP
|
|
48-55: Air temperature 1.1 - 4.2, LCP
|
|
56,57: actual temperature 1,2, LCP
|
|
58: water inlet temperature, LCP
|
|
59: water outlet temperature, LCP
|
|
60: water flow
|
|
61: fan speed (desired value)
|
|
62: status valve, LCP
|
|
63: status LCP
|
|
64: temperature difference water temperatures
|
|
65: control temperature 1, LCP
|
|
66: control temperature 2, LCP
|
|
67: condensate pump, duration, LCP
|
|
68: condensate pump, cycles, LCP
|
|
72: total energy*10 (kWh), PSM
|
|
73: total power*10 (kW), PSM
|
|
74: frequency*10 (Hz), PSM
|
|
75: voltage*10 (V), PSM
|
|
76: voltage status, PSM
|
|
77: current*10 (A), PSM
|
|
78: current status, PSM
|
|
79: power*10 (kW) per phase, PSM
|
|
80: energy*10 (kWh) per phase, PSM
|
|
81: temporary energy*10 (kWh) per phase, PSM
|
|
100: temperature sensor, wireless
|
|
101: temperature sensor (combi), wireless
|
|
102: humidity sensor, wireless
|
|
103: access sensor, wireless
|
|
104: user sensor with normally opened contact, wireless
|
|
105: user sensor with normally closed contact, wireless
|
|
106: analog sensor 4..20mA, wireless"
|
|
::= { cmcTcUnit2SensorEntry 2 }
|
|
|
|
unit2SensorText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each sensor (entry in the table)"
|
|
::= { cmcTcUnit2SensorEntry 3 }
|
|
|
|
unit2SensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
warning(7),
|
|
tooLow(8),
|
|
tooHigh(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the sensor"
|
|
::= { cmcTcUnit2SensorEntry 4 }
|
|
|
|
unit2SensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { cmcTcUnit2SensorEntry 5 }
|
|
|
|
unit2SensorSetHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for high setpoint of sensor"
|
|
::= { cmcTcUnit2SensorEntry 6 }
|
|
|
|
unit2SensorSetLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for low setpoint of sensor,
|
|
also used as alarm delay"
|
|
::= { cmcTcUnit2SensorEntry 7 }
|
|
|
|
unit2SensorSetWarn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for warning setpoint of sensor,
|
|
also used as fan threshold"
|
|
::= { cmcTcUnit2SensorEntry 8 }
|
|
|
|
-- table END
|
|
|
|
-- Outputs
|
|
cmcTcUnit2NumberOfOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outputs available on sensor unit 2"
|
|
::= { cmcTcStatusUnit2Outputs 1 }
|
|
|
|
-- table with entry for each output available on this unit
|
|
|
|
cmcTcUnit2OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of output table"
|
|
::= { cmcTcStatusUnit2Outputs 2 }
|
|
|
|
cmcTcUnit2OutputEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of output table"
|
|
INDEX { unit2OutputIndex }
|
|
::= { cmcTcUnit2OutputTable 1 }
|
|
|
|
CmcTcUnit2OutputEntry ::=
|
|
SEQUENCE {
|
|
unit2OutputIndex
|
|
INTEGER,
|
|
unit2OutputType
|
|
INTEGER,
|
|
unit2OutputText
|
|
DisplayString,
|
|
unit2OutputStatus
|
|
INTEGER,
|
|
unit2OutputValue
|
|
INTEGER,
|
|
unit2OutputSet
|
|
INTEGER,
|
|
unit2OutputConfig
|
|
INTEGER,
|
|
unit2OutputDelay
|
|
INTEGER,
|
|
unit2OutputTimeoutAction
|
|
INTEGER
|
|
}
|
|
|
|
unit2OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of output entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit2NumberOfOutputs."
|
|
::= { cmcTcUnit2OutputEntry 1 }
|
|
|
|
unit2OutputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
doorLock (4),
|
|
univLock1 (5),
|
|
univLock2 (6),
|
|
fan (7),
|
|
fanSpeedContr (8),
|
|
universalOut (9),
|
|
roomLock(10),
|
|
powerOut(11),
|
|
doorLockMaster(12),
|
|
doorLockFRi (13),
|
|
setpoint (14),
|
|
setpointTimax (15),
|
|
hysteresisRCT (16),
|
|
commandRCT (17),
|
|
relayPSM (18),
|
|
setHighPSM (19),
|
|
setLowPSM (20),
|
|
setpointRTT (21),
|
|
setTimaxRTT (22),
|
|
powerOut1(23),
|
|
controlModeLCP (30),
|
|
minFanSpeedLCP (31),
|
|
minDeltaTLCP (32),
|
|
maxDeltaTLCP (33),
|
|
kPLCP (34),
|
|
kILCP (35),
|
|
kDLCP (36),
|
|
flowRateLCP(37),
|
|
cwValueLCP (38),
|
|
deltaTLCP (39),
|
|
ctrModLCP (40),
|
|
voltHighPSM (42),
|
|
voltLowPSM (43),
|
|
ampHighPSM (44),
|
|
ampLowPSM (45),
|
|
commandPSM (46)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of output which is connected to sensor unit 2 to output[unit2OutputIndex]
|
|
1: no output connected
|
|
2: output failure
|
|
3: value overflow
|
|
4: output type 1, door locking TS8,Ergoform
|
|
5: output type 2, universal lock 1, lock with power
|
|
6: output type 3, universal lock 2, unlock with power
|
|
7: output type 4, fan relay
|
|
8: output type 5, fan controlled
|
|
9: output type 6, universal relay output
|
|
10: output type 7, room door lock
|
|
11: output type 8, power output
|
|
12: output type 9, door lock with Master key
|
|
13: output type 10, door lock FR(i)
|
|
14: setpoint (FCS, RTT)
|
|
15: setpoint temperature monitoring (RTT)
|
|
16: hysteresis of setpoint (RCT)
|
|
17: command for remote control of RCT
|
|
18: relay PSM, 1=On, 0=Off
|
|
19: high setpoint current monitoring PSM
|
|
20: low setpoint current monitoring PSM
|
|
21: setpoint temperature RTT
|
|
22: setpoint temperature monitoring RTT
|
|
23: power output 20A
|
|
30: control mode LCP
|
|
31: min fan speed (fan control) LCP
|
|
32: min delta T (fan control) LCP
|
|
33: max delta T (fan control) LCP
|
|
34: PID controller, KP, LCP
|
|
35: PID controller, KI, LCP
|
|
36 PID controller, KD, LCP
|
|
37 flowrate flowmeter, LCP
|
|
38: cw value of water (default: 4187) LCP
|
|
39: deltaT, LCP
|
|
40: control mode, LCP
|
|
42: setpoint high voltage PSM
|
|
43: setpoint low voltage PSM
|
|
44: setpoint high current PSM
|
|
45: setpoint low current PSM
|
|
46: command PSM"
|
|
::= { cmcTcUnit2OutputEntry 2 }
|
|
|
|
|
|
unit2OutputText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each output (entry in the table)"
|
|
::= { cmcTcUnit2OutputEntry 3 }
|
|
|
|
unit2OutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
setOff(7),
|
|
setOn(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the output"
|
|
::= { cmcTcUnit2OutputEntry 4 }
|
|
|
|
unit2OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Signed value for output"
|
|
::= { cmcTcUnit2OutputEntry 5 }
|
|
|
|
unit2OutputSet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2),
|
|
lock (3),
|
|
unlock (4),
|
|
unlockDelay (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command for output"
|
|
::= { cmcTcUnit2OutputEntry 6 }
|
|
|
|
unit2OutputConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disRemote (1),
|
|
enRemote (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration for output
|
|
1: disable remote control (e.g. keypad)
|
|
2: enable remote control "
|
|
::= { cmcTcUnit2OutputEntry 7 }
|
|
|
|
unit2OutputDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unsigned Value for delay,
|
|
after this time the output will fall into the previous state"
|
|
::= { cmcTcUnit2OutputEntry 8 }
|
|
|
|
unit2OutputTimeoutAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stay (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State for output if timeout (RS422) occurs"
|
|
::= { cmcTcUnit2OutputEntry 9 }
|
|
|
|
-- Alarms
|
|
|
|
cmcTcUnit2NumberOfMsgs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of alarms that can be created with sensor unit 2"
|
|
::= { cmcTcStatusUnit2Msg 1 }
|
|
|
|
-- table with entry for each alarm available on this unit
|
|
|
|
cmcTcUnit2MsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit2MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of message table"
|
|
::= { cmcTcStatusUnit2Msg 2 }
|
|
|
|
cmcTcUnit2MsgEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit2MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of message table"
|
|
INDEX { unit2MsgIndex }
|
|
::= { cmcTcUnit2MsgTable 1 }
|
|
|
|
CmcTcUnit2MsgEntry ::=
|
|
SEQUENCE {
|
|
unit2MsgIndex
|
|
INTEGER,
|
|
unit2MsgText
|
|
DisplayString,
|
|
unit2MsgStatus
|
|
INTEGER,
|
|
unit2MsgRelay
|
|
INTEGER,
|
|
unit2MsgBeeper
|
|
INTEGER,
|
|
unit2MsgTrap1
|
|
INTEGER,
|
|
unit2MsgTrap2
|
|
INTEGER,
|
|
unit2MsgTrap3
|
|
INTEGER,
|
|
unit2MsgTrap4
|
|
INTEGER,
|
|
unit2MsgQuit
|
|
INTEGER
|
|
}
|
|
|
|
unit2MsgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of alarm entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit2NumberOfMsgs."
|
|
::= { cmcTcUnit2MsgEntry 1 }
|
|
|
|
unit2MsgText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each message (entry in the table)"
|
|
::= { cmcTcUnit2MsgEntry 2 }
|
|
|
|
unit2MsgStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
configChanged(2),
|
|
error(3),
|
|
ok(4),
|
|
alarm(5),
|
|
warning(6),
|
|
tooLow(7),
|
|
tooHigh(8),
|
|
setOff(9),
|
|
setOn(10),
|
|
open(11),
|
|
closed(12),
|
|
locked(13),
|
|
unlRemote(14),
|
|
unlReaderKeypad(15),
|
|
unlSNMP(16),
|
|
unlWEB(17),
|
|
unlTimer(18),
|
|
noAccess(19),
|
|
circuit1 (20),
|
|
circuit2 (21),
|
|
lowBatt (22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual message status
|
|
1: not available
|
|
2: configuration has changed (sensor new, changed, lost)
|
|
3: error
|
|
4: OK
|
|
5: alarm, e.g. smoke, vibration...
|
|
6: warning of analog value, value reached warning threshold
|
|
7: analog value too low, value reached low threshold
|
|
8: analog value too high, value reached high threshold
|
|
9: output is set to OFF
|
|
10: output is set to ON
|
|
11: door is open
|
|
12: door is closed
|
|
13: door is locked
|
|
14: door is unlocked by remote input, e.g. external cardreader
|
|
15: door is unlocked by reader or keypad connected to I2C
|
|
16: door is unlocked by SNMP set command (unit1OutputSet)
|
|
17: door is unlocked by WEB
|
|
18: door is unlocked by timer
|
|
19: no access, wrong keycode or cardnumber
|
|
20: orientation of PSM-Unit is circuit 1
|
|
21: orientation of PSM-Unit is circuit 2
|
|
22: battery low, wireless sensor"
|
|
::= { cmcTcUnit2MsgEntry 3 }
|
|
|
|
unit2MsgRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm relay for this alarm
|
|
2: no switching of alarm relay
|
|
1: switching of alarm relay"
|
|
::= { cmcTcUnit2MsgEntry 4 }
|
|
|
|
unit2MsgBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm beeper for this alarm
|
|
2: no audible alarm
|
|
1: audible alarm"
|
|
::= { cmcTcUnit2MsgEntry 5 }
|
|
|
|
unit2MsgTrap1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 1 activated"
|
|
::= { cmcTcUnit2MsgEntry 6 }
|
|
|
|
unit2MsgTrap2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 2 activated"
|
|
::= { cmcTcUnit2MsgEntry 7 }
|
|
|
|
unit2MsgTrap3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 3 activated"
|
|
::= { cmcTcUnit2MsgEntry 8 }
|
|
|
|
unit2MsgTrap4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 4 and Event Logging activated"
|
|
::= { cmcTcUnit2MsgEntry 9 }
|
|
|
|
unit2MsgQuit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset of this alarm
|
|
1: auto
|
|
2: manual, alarm needs confirmation, e. g. with 'C' key"
|
|
::= { cmcTcUnit2MsgEntry 10 }
|
|
-- table END
|
|
|
|
-- unit 3
|
|
cmcTcUnit3TypeOfDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
unitIO (2),
|
|
unitAccess (3),
|
|
unitClimate (4),
|
|
unitFCS (5),
|
|
unitRTT (6),
|
|
unitRCT (7),
|
|
unitPSM (8),
|
|
unitPSM8 (9),
|
|
unitPSMMetered (10),
|
|
unitIOWireless (11),
|
|
unitPSM6Schuko (12),
|
|
unitPSM6C19 (13)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor unit connected to port 3"
|
|
::= { cmcTcStatusSensorUnit3 1 }
|
|
|
|
cmcTcUnit3Text OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for sensor unit connected to port 3"
|
|
::= { cmcTcStatusSensorUnit3 2 }
|
|
|
|
cmcTcUnit3Serial OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serialnumber of sensor unit connected to port 3"
|
|
::= { cmcTcStatusSensorUnit3 3 }
|
|
|
|
cmcTcUnit3Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
error(2),
|
|
changed(3),
|
|
quit(4),
|
|
timeout(5),
|
|
detected(6),
|
|
notAvail(7),
|
|
lowPower(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Status sensor unit connected to port 3
|
|
(1) OK
|
|
(2) error, e. g. value overflow
|
|
(3) configuration of sensor unit has changed, confirmation required
|
|
(4) Quit from sensor unit to confirm configuration changes
|
|
(5) timeout of sensor unit, confirmation required to unload this unit
|
|
(6) sensor unit detected, needs to be confirmed
|
|
(7) unit is not available
|
|
(8) supply voltage is too low"
|
|
::= { cmcTcStatusSensorUnit3 4 }
|
|
|
|
-- Sensors
|
|
cmcTcUnit3NumberOfSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors connected to sensor unit 3"
|
|
::= { cmcTcStatusUnit3Sensors 1 }
|
|
|
|
-- table with entry for each sensor available on this unit
|
|
|
|
cmcTcUnit3SensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit3SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of sensor table"
|
|
::= { cmcTcStatusUnit3Sensors 2 }
|
|
|
|
cmcTcUnit3SensorEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit3SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of sensor table"
|
|
INDEX { unit3SensorIndex }
|
|
::= { cmcTcUnit3SensorTable 1 }
|
|
|
|
CmcTcUnit3SensorEntry ::=
|
|
SEQUENCE {
|
|
unit3SensorIndex
|
|
INTEGER,
|
|
unit3SensorType
|
|
INTEGER,
|
|
unit3SensorText
|
|
DisplayString,
|
|
unit3SensorStatus
|
|
INTEGER,
|
|
unit3SensorValue
|
|
INTEGER,
|
|
unit3SensorSetHigh
|
|
INTEGER,
|
|
unit3SensorSetLow
|
|
INTEGER,
|
|
unit3SensorSetWarn
|
|
INTEGER
|
|
}
|
|
|
|
unit3SensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of value entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit3NumberOfSensors."
|
|
::= { cmcTcUnit3SensorEntry 1 }
|
|
|
|
unit3SensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
access (4),
|
|
vibration (5),
|
|
motion (6),
|
|
smoke (7),
|
|
airFlow (8),
|
|
type6 (9),
|
|
temperature(10),
|
|
current4to20(11),
|
|
humidity(12),
|
|
userNO (13),
|
|
userNC (14),
|
|
lock (15),
|
|
unlock (16),
|
|
voltOK (17),
|
|
voltage (18),
|
|
fanOK (19),
|
|
readerKeypad (20),
|
|
dutyPWM (21),
|
|
fanStatus (22),
|
|
leakage (23),
|
|
warningRTT (24),
|
|
alarmRTT (25),
|
|
filterRTT (26),
|
|
heatflowRCT (27),
|
|
alarmRCT (28),
|
|
warningRCT (29),
|
|
currentPSM (30),
|
|
statusPSM (31),
|
|
positionPSM (32),
|
|
airFlap (33),
|
|
acoustic (34),
|
|
detACfault (35),
|
|
detACfirstAlarm (36),
|
|
detACmainAlarm (37),
|
|
rpm11LCP (40),
|
|
rpm12LCP (41),
|
|
rpm21LCP (42),
|
|
rpm22LCP (43),
|
|
rpm31LCP (44),
|
|
rpm32LCP (45),
|
|
rpm41LCP (46),
|
|
rpm42LCP (47),
|
|
airTemp11LCP (48),
|
|
airTemp12LCP (49),
|
|
airTemp21LCP (50),
|
|
airTemp22LCP (51),
|
|
airTemp31LCP (52),
|
|
airTemp32LCP (53),
|
|
airTemp41LCP (54),
|
|
airTemp42LCP (55),
|
|
temp1LCP (56),
|
|
temp2LCP (57),
|
|
waterInTemp (58),
|
|
waterOutTemp (59),
|
|
waterFlow (60),
|
|
fanSpeed (61),
|
|
valve (62),
|
|
statusLCP (63),
|
|
waterDelta (64),
|
|
valveActual (65),
|
|
contrTemp2 (66),
|
|
condensateDuration (67),
|
|
condensateCycles (68),
|
|
totalKWhPSM (72),
|
|
totalKWPSM (73),
|
|
frequencyPSM (74),
|
|
voltagePSM (75),
|
|
voltStatusPSM (76),
|
|
amperePSM (77),
|
|
ampStatusPSM (78),
|
|
kWPSM (79),
|
|
kWhPSM (80),
|
|
kWhTempPSM (81),
|
|
temperatureWL (100),
|
|
temperature1WL (101),
|
|
humidityWL (102),
|
|
accessWL (103),
|
|
userNOWL (104),
|
|
userNCWL (105),
|
|
analogWL (106)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor which is connected to sensor unit 3 to sensor[unit3SensorIndex]
|
|
1: no sensor connected
|
|
2: sensor failure
|
|
3: value overflow
|
|
4: sensor type 1, access sensor
|
|
5: sensor type 2, vibration sensor
|
|
6: sensor type 3, motion sensor
|
|
7: sensor type 4, smoke sensor
|
|
8: sensor type 5, air flow sensor
|
|
9: sensor type 6, reserved
|
|
10: sensor type 7, temperature sensor
|
|
11: sensor type 8, 4..20mA sensor
|
|
12: sensor type 9, humidity sensor
|
|
13: user sensor with normally opened contact
|
|
14: user sensor with normally closed contact
|
|
15: door locked sensor from locking device
|
|
16: remote unlock sensor (e.g. external keypad)
|
|
17: voltage sensor, indicates status of main voltage
|
|
18: voltage value
|
|
19: fan status
|
|
20: cardreader or keypad, connected to I2C port
|
|
21: duty cycle of fan, FCS-Unit
|
|
22: status of fan, FCS-Unit
|
|
23: leakage sensor
|
|
24: warning, RittalTopTherm(RTT)-Unit
|
|
25: alarm, RittalTopTherm-Unit
|
|
26: temperature difference filter monitor, RTT-Unit
|
|
27: heatflow RCT-Unit
|
|
28: alarm RCT-Unit
|
|
29: warning RCT-Unit
|
|
30: actual current*10, PSM-Unit
|
|
31: status PSM-Unit
|
|
32: position PSM-Unit, normal/reversed = circuit 1/2
|
|
33: air Flap
|
|
34: acoustic sensor
|
|
35: DET-AC fault (extinguisher)
|
|
36: DET-AC first alarm (extinguisher)
|
|
37: DET-AC main alarm (extinguisher)
|
|
40-47: RPM Fan 1.1 - Fan 4.2, LCP
|
|
48-55: Air temperature 1.1 - 4.2, LCP
|
|
56,57: actual temperature 1,2, LCP
|
|
58: water inlet temperature, LCP
|
|
59: water outlet temperature, LCP
|
|
60: water flow
|
|
61: fan speed (desired value)
|
|
62: status valve, LCP
|
|
63: status LCP
|
|
64: temperature difference water temperatures
|
|
65: control temperature 1, LCP
|
|
66: control temperature 2, LCP
|
|
67: condensate pump, duration, LCP
|
|
68: condensate pump, cycles, LCP
|
|
72: total energy*10 (kWh), PSM
|
|
73: total power*10 (kW), PSM
|
|
74: frequency*10 (Hz), PSM
|
|
75: voltage*10 (V), PSM
|
|
76: voltage status, PSM
|
|
77: current*10 (A), PSM
|
|
78: current status, PSM
|
|
79: power*10 (kW) per phase, PSM
|
|
80: energy*10 (kWh) per phase, PSM
|
|
81: temporary energy*10 (kWh) per phase, PSM
|
|
100: temperature sensor, wireless
|
|
101: temperature sensor (combi), wireless
|
|
102: humidity sensor, wireless
|
|
103: access sensor, wireless
|
|
104: user sensor with normally opened contact, wireless
|
|
105: user sensor with normally closed contact, wireless
|
|
106: analog sensor 4..20mA, wireless"
|
|
::= { cmcTcUnit3SensorEntry 2 }
|
|
|
|
|
|
unit3SensorText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each sensor (entry in the table)"
|
|
::= { cmcTcUnit3SensorEntry 3 }
|
|
|
|
unit3SensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
warning(7),
|
|
tooLow(8),
|
|
tooHigh(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the sensor"
|
|
::= { cmcTcUnit3SensorEntry 4 }
|
|
|
|
unit3SensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { cmcTcUnit3SensorEntry 5 }
|
|
|
|
unit3SensorSetHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for high setpoint of sensor"
|
|
::= { cmcTcUnit3SensorEntry 6 }
|
|
|
|
unit3SensorSetLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for low setpoint of sensor"
|
|
::= { cmcTcUnit3SensorEntry 7 }
|
|
|
|
unit3SensorSetWarn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for warning setpoint of sensor,
|
|
also used as fan threshold"
|
|
::= { cmcTcUnit3SensorEntry 8 }
|
|
-- table END
|
|
|
|
-- Outputs
|
|
cmcTcUnit3NumberOfOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outputs available on sensor unit 3"
|
|
::= { cmcTcStatusUnit3Outputs 1 }
|
|
|
|
-- table with entry for each output available on this unit
|
|
|
|
cmcTcUnit3OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit3OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of output table"
|
|
::= { cmcTcStatusUnit3Outputs 2 }
|
|
|
|
cmcTcUnit3OutputEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit3OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of output table"
|
|
INDEX { unit3OutputIndex }
|
|
::= { cmcTcUnit3OutputTable 1 }
|
|
|
|
CmcTcUnit3OutputEntry ::=
|
|
SEQUENCE {
|
|
unit3OutputIndex
|
|
INTEGER,
|
|
unit3OutputType
|
|
INTEGER,
|
|
unit3OutputText
|
|
DisplayString,
|
|
unit3OutputStatus
|
|
INTEGER,
|
|
unit3OutputValue
|
|
INTEGER,
|
|
unit3OutputSet
|
|
INTEGER,
|
|
unit3OutputConfig
|
|
INTEGER,
|
|
unit3OutputDelay
|
|
INTEGER,
|
|
unit3OutputTimeoutAction
|
|
INTEGER
|
|
}
|
|
|
|
unit3OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of output entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit3NumberOfOutputs."
|
|
::= { cmcTcUnit3OutputEntry 1 }
|
|
|
|
unit3OutputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
doorLock (4),
|
|
univLock1 (5),
|
|
univLock2 (6),
|
|
fan (7),
|
|
fanSpeedContr (8),
|
|
universalOut (9),
|
|
roomLock(10),
|
|
powerOut(11),
|
|
doorLockMaster(12),
|
|
doorLockFRi (13),
|
|
setpoint (14),
|
|
setpointTimax (15),
|
|
hysteresisRCT (16),
|
|
commandRCT (17),
|
|
relayPSM (18),
|
|
setHighPSM (19),
|
|
setLowPSM (20),
|
|
setpointRTT (21),
|
|
setTimaxRTT (22),
|
|
powerOut1(23),
|
|
controlModeLCP (30),
|
|
minFanSpeedLCP (31),
|
|
minDeltaTLCP (32),
|
|
maxDeltaTLCP (33),
|
|
kPLCP (34),
|
|
kILCP (35),
|
|
kDLCP (36),
|
|
flowRateLCP(37),
|
|
cwValueLCP (38),
|
|
deltaTLCP (39),
|
|
ctrModLCP (40),
|
|
voltHighPSM (42),
|
|
voltLowPSM (43),
|
|
ampHighPSM (44),
|
|
ampLowPSM (45),
|
|
commandPSM (46)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of output which is connected to sensor unit 3 to output[unit3OutputIndex]
|
|
1: no output connected
|
|
2: output failure
|
|
3: value overflow
|
|
4: output type 1, door locking TS8,Ergoform
|
|
5: output type 2, universal lock 1, lock with power
|
|
6: output type 3, universal lock 2, unlock with power
|
|
7: output type 4, fan relay
|
|
8: output type 5, fan controlled
|
|
9: output type 6, universal relay output
|
|
10: output type 7, room door lock
|
|
11: output type 8, power output
|
|
12: output type 9, door lock with Master key
|
|
13: output type 10, door lock FR(i)
|
|
14: setpoint (FCS, RTT)
|
|
15: setpoint temperature monitoring (RTT)
|
|
16: hysteresis of setpoint (RCT)
|
|
17: command for remote control of RCT
|
|
18: relay PSM, 1=On, 0=Off
|
|
19: high setpoint current monitoring PSM
|
|
20: low setpoint current monitoring PSM
|
|
21: setpoint temperature RTT
|
|
22: setpoint temperature monitoring RTT
|
|
23: power output 20A
|
|
30: control mode LCP
|
|
31: min fan speed (fan control) LCP
|
|
32: min delta T (fan control) LCP
|
|
33: max delta T (fan control) LCP
|
|
34: PID controller, KP, LCP
|
|
35: PID controller, KI, LCP
|
|
36 PID controller, KD, LCP
|
|
37 flowrate flowmeter, LCP
|
|
38: cw value of water (default: 4187) LCP
|
|
39: deltaT, LCP
|
|
40: control mode, LCP
|
|
42: setpoint high voltage PSM
|
|
43: setpoint low voltage PSM
|
|
44: setpoint high current PSM
|
|
45: setpoint low current PSM
|
|
46: command PSM"
|
|
::= { cmcTcUnit3OutputEntry 2 }
|
|
|
|
|
|
unit3OutputText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each output (entry in the table)"
|
|
::= { cmcTcUnit3OutputEntry 3 }
|
|
|
|
unit3OutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
setOff(7),
|
|
setOn(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the output"
|
|
::= { cmcTcUnit3OutputEntry 4 }
|
|
|
|
unit3OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for output"
|
|
::= { cmcTcUnit3OutputEntry 5 }
|
|
|
|
unit3OutputSet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2),
|
|
lock (3),
|
|
unlock (4),
|
|
unlockDelay (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command for output"
|
|
::= { cmcTcUnit3OutputEntry 6 }
|
|
|
|
unit3OutputConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disRemote (1),
|
|
enRemote (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration for output
|
|
1: disable remote control (e.g. keypad)
|
|
2: enable remote control "
|
|
::= { cmcTcUnit3OutputEntry 7 }
|
|
|
|
unit3OutputDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unsigned Value for delay,
|
|
after this time the output will fall into the previous state"
|
|
::= { cmcTcUnit3OutputEntry 8 }
|
|
|
|
unit3OutputTimeoutAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stay (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State for output if timeout (RS422) occurs"
|
|
::= { cmcTcUnit3OutputEntry 9 }
|
|
|
|
|
|
-- Msgs
|
|
|
|
cmcTcUnit3NumberOfMsgs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of alarms that can be created with sensor unit 3"
|
|
::= { cmcTcStatusUnit3Msg 1 }
|
|
|
|
-- table with entry for each alarm available on this unit
|
|
|
|
cmcTcUnit3MsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit3MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of message table"
|
|
::= { cmcTcStatusUnit3Msg 2 }
|
|
|
|
cmcTcUnit3MsgEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit3MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of message table"
|
|
INDEX { unit3MsgIndex }
|
|
::= { cmcTcUnit3MsgTable 1 }
|
|
|
|
CmcTcUnit3MsgEntry ::=
|
|
SEQUENCE {
|
|
unit3MsgIndex
|
|
INTEGER,
|
|
unit3MsgText
|
|
DisplayString,
|
|
unit3MsgStatus
|
|
INTEGER,
|
|
unit3MsgRelay
|
|
INTEGER,
|
|
unit3MsgBeeper
|
|
INTEGER,
|
|
unit3MsgTrap1
|
|
INTEGER,
|
|
unit3MsgTrap2
|
|
INTEGER,
|
|
unit3MsgTrap3
|
|
INTEGER,
|
|
unit3MsgTrap4
|
|
INTEGER,
|
|
unit3MsgQuit
|
|
INTEGER
|
|
}
|
|
|
|
unit3MsgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of alarm entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit3NumberOfMsgs."
|
|
::= { cmcTcUnit3MsgEntry 1 }
|
|
|
|
unit3MsgText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each message (entry in the table)"
|
|
::= { cmcTcUnit3MsgEntry 2 }
|
|
|
|
unit3MsgStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
configChanged(2),
|
|
error(3),
|
|
ok(4),
|
|
alarm(5),
|
|
warning(6),
|
|
tooLow(7),
|
|
tooHigh(8),
|
|
setOff(9),
|
|
setOn(10),
|
|
open(11),
|
|
closed(12),
|
|
locked(13),
|
|
unlRemote(14),
|
|
unlReaderKeypad(15),
|
|
unlSNMP(16),
|
|
unlWEB(17),
|
|
unlTimer(18),
|
|
noAccess(19),
|
|
circuit1 (20),
|
|
circuit2 (21),
|
|
lowBatt (22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual message status
|
|
1: not available
|
|
2: configuration has changed (sensor new, changed, lost)
|
|
3: error
|
|
4: OK
|
|
5: alarm, e.g. smoke, vibration...
|
|
6: warning of analog value, value reached warning threshold
|
|
7: analog value too low, value reached low threshold
|
|
8: analog value too high, value reached high threshold
|
|
9: output is set to OFF
|
|
10: output is set to ON
|
|
11: door is open
|
|
12: door is closed
|
|
13: door is locked
|
|
14: door is unlocked by remote input, e.g. external cardreader
|
|
15: door is unlocked by reader or keypad connected to I2C
|
|
16: door is unlocked by SNMP set command (unit1OutputSet)
|
|
17: door is unlocked by WEB
|
|
18: door is unlocked by timer
|
|
19: no access, wrong keycode or cardnumber
|
|
20: orientation of PSM-Unit is circuit 1
|
|
21: orientation of PSM-Unit is circuit 2
|
|
22: battery low, wireless sensor"
|
|
::= { cmcTcUnit3MsgEntry 3 }
|
|
|
|
unit3MsgRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm relay for this alarm
|
|
1: no switching of alarm relay
|
|
2: switching of alarm relay"
|
|
::= { cmcTcUnit3MsgEntry 4 }
|
|
|
|
unit3MsgBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm beeper for this alarm
|
|
1: no audible alarm
|
|
2: audible alarm"
|
|
::= { cmcTcUnit3MsgEntry 5 }
|
|
|
|
unit3MsgTrap1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 1 activated"
|
|
::= { cmcTcUnit3MsgEntry 6 }
|
|
|
|
unit3MsgTrap2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 2 activated"
|
|
::= { cmcTcUnit3MsgEntry 7 }
|
|
|
|
unit3MsgTrap3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 3 activated"
|
|
::= { cmcTcUnit3MsgEntry 8 }
|
|
|
|
unit3MsgTrap4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 4 and Event Logging activated"
|
|
::= { cmcTcUnit3MsgEntry 9 }
|
|
|
|
unit3MsgQuit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset of this alarm
|
|
1: auto
|
|
2: manual, alarm needs confirmation, e. g. with 'C' key"
|
|
::= { cmcTcUnit3MsgEntry 10 }
|
|
-- table END
|
|
|
|
-- unit4
|
|
cmcTcUnit4TypeOfDevice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
unitIO (2),
|
|
unitAccess (3),
|
|
unitClimate (4),
|
|
unitFCS (5),
|
|
unitRTT (6),
|
|
unitRCT (7),
|
|
unitPSM (8),
|
|
unitPSM8 (9),
|
|
unitPSMMetered (10),
|
|
unitIOWireless (11),
|
|
unitPSM6Schuko (12),
|
|
unitPSM6C19 (13)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor unit connected to port 4"
|
|
::= { cmcTcStatusSensorUnit4 1 }
|
|
|
|
cmcTcUnit4Text OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for sensor unit connected to port 4"
|
|
::= { cmcTcStatusSensorUnit4 2 }
|
|
|
|
cmcTcUnit4Serial OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Serialnumber of sensor unit connected to port 4"
|
|
::= { cmcTcStatusSensorUnit4 3 }
|
|
|
|
cmcTcUnit4Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
error(2),
|
|
changed(3),
|
|
quit(4),
|
|
timeout(5),
|
|
detected(6),
|
|
notAvail(7),
|
|
lowPower(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"General Status sensor unit connected to port 4
|
|
(1) OK
|
|
(2) error, e. g. value overflow
|
|
(3) configuration of sensor unit has changed, confirmation required
|
|
(4) Quit from sensor unit to confirm configuration changes
|
|
(5) timeout of sensor unit, confirmation required to unload this unit
|
|
(6) sensor unit detected, needs to be confirmed
|
|
(7) unit is not available
|
|
(8) supply voltage is too low"
|
|
|
|
::= { cmcTcStatusSensorUnit4 4 }
|
|
|
|
-- Sensors
|
|
cmcTcUnit4NumberOfSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors connected to sensor unit 4"
|
|
::= { cmcTcStatusUnit4Sensors 1 }
|
|
|
|
-- table with entry for each sensor available on this unit
|
|
|
|
cmcTcUnit4SensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit4SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of sensor table"
|
|
::= { cmcTcStatusUnit4Sensors 2 }
|
|
|
|
cmcTcUnit4SensorEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit4SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of sensor table"
|
|
INDEX { unit4SensorIndex }
|
|
::= { cmcTcUnit4SensorTable 1 }
|
|
|
|
CmcTcUnit4SensorEntry ::=
|
|
SEQUENCE {
|
|
unit4SensorIndex
|
|
INTEGER,
|
|
unit4SensorType
|
|
INTEGER,
|
|
unit4SensorText
|
|
DisplayString,
|
|
unit4SensorStatus
|
|
INTEGER,
|
|
unit4SensorValue
|
|
INTEGER,
|
|
unit4SensorSetHigh
|
|
INTEGER,
|
|
unit4SensorSetLow
|
|
INTEGER,
|
|
unit4SensorSetWarn
|
|
INTEGER
|
|
}
|
|
|
|
unit4SensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of value entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit4NumberOfSensors."
|
|
::= { cmcTcUnit4SensorEntry 1 }
|
|
|
|
unit4SensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
access (4),
|
|
vibration (5),
|
|
motion (6),
|
|
smoke (7),
|
|
airFlow (8),
|
|
type6 (9),
|
|
temperature(10),
|
|
current4to20(11),
|
|
humidity(12),
|
|
userNO (13),
|
|
userNC (14),
|
|
lock (15),
|
|
unlock (16),
|
|
voltOK (17),
|
|
voltage (18),
|
|
fanOK (19),
|
|
readerKeypad (20),
|
|
dutyPWM (21),
|
|
fanStatus (22),
|
|
leakage (23),
|
|
warningRTT (24),
|
|
alarmRTT (25),
|
|
filterRTT (26),
|
|
heatflowRCT (27),
|
|
alarmRCT (28),
|
|
warningRCT (29),
|
|
currentPSM (30),
|
|
statusPSM (31),
|
|
positionPSM (32),
|
|
airFlap (33),
|
|
acoustic (34),
|
|
detACfault (35),
|
|
detACfirstAlarm (36),
|
|
detACmainAlarm (37),
|
|
rpm11LCP (40),
|
|
rpm12LCP (41),
|
|
rpm21LCP (42),
|
|
rpm22LCP (43),
|
|
rpm31LCP (44),
|
|
rpm32LCP (45),
|
|
rpm41LCP (46),
|
|
rpm42LCP (47),
|
|
airTemp11LCP (48),
|
|
airTemp12LCP (49),
|
|
airTemp21LCP (50),
|
|
airTemp22LCP (51),
|
|
airTemp31LCP (52),
|
|
airTemp32LCP (53),
|
|
airTemp41LCP (54),
|
|
airTemp42LCP (55),
|
|
temp1LCP (56),
|
|
temp2LCP (57),
|
|
waterInTemp (58),
|
|
waterOutTemp (59),
|
|
waterFlow (60),
|
|
fanSpeed (61),
|
|
valve (62),
|
|
statusLCP (63),
|
|
waterDelta (64),
|
|
valveActual (65),
|
|
contrTemp2 (66),
|
|
condensateDuration (67),
|
|
condensateCycles (68),
|
|
totalKWhPSM (72),
|
|
totalKWPSM (73),
|
|
frequencyPSM (74),
|
|
voltagePSM (75),
|
|
voltStatusPSM (76),
|
|
amperePSM (77),
|
|
ampStatusPSM (78),
|
|
kWPSM (79),
|
|
kWhPSM (80),
|
|
kWhTempPSM (81),
|
|
temperatureWL (100),
|
|
temperature1WL (101),
|
|
humidityWL (102),
|
|
accessWL (103),
|
|
userNOWL (104),
|
|
userNCWL (105),
|
|
analogWL (106)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of sensor which is connected to sensor unit 4 to sensor[unit4SensorIndex]
|
|
1: no sensor connected
|
|
2: sensor failure
|
|
3: value overflow
|
|
4: sensor type 1, access sensor
|
|
5: sensor type 2, vibration sensor
|
|
6: sensor type 3, motion sensor
|
|
7: sensor type 4, smoke sensor
|
|
8: sensor type 5, air flow sensor
|
|
9: sensor type 6, reserved
|
|
10: sensor type 7, temperature sensor
|
|
11: sensor type 8, 4..20mA sensor
|
|
12: sensor type 9, humidity sensor
|
|
13: user sensor with normally opened contact
|
|
14: user sensor with normally closed contact
|
|
15: door locked sensor from locking device
|
|
16: remote unlock sensor (e.g. external keypad)
|
|
17: voltage sensor, indicates status of main voltage
|
|
18: voltage value
|
|
19: fan status
|
|
20: cardreader or keypad, connected to I2C port
|
|
21: duty cycle of fan, FCS-Unit
|
|
22: status of fan, FCS-Unit
|
|
23: leakage sensor
|
|
24: warning, RittalTopTherm(RTT)-Unit
|
|
25: alarm, RittalTopTherm-Unit
|
|
26: temperature difference filter monitor, RTT-Unit
|
|
27: heatflow RCT-Unit
|
|
28: alarm RCT-Unit
|
|
29: warning RCT-Unit
|
|
30: actual current*10, PSM-Unit
|
|
31: status PSM-Unit
|
|
32: position PSM-Unit, normal/reversed = circuit 1/2
|
|
33: air Flap
|
|
34: acoustic sensor
|
|
35: DET-AC fault (extinguisher)
|
|
36: DET-AC first alarm (extinguisher)
|
|
37: DET-AC main alarm (extinguisher)
|
|
40-47: RPM Fan 1.1 - Fan 4.2, LCP
|
|
48-55: Air temperature 1.1 - 4.2, LCP
|
|
56,57: actual temperature 1,2, LCP
|
|
58: water inlet temperature, LCP
|
|
59: water outlet temperature, LCP
|
|
60: water flow
|
|
61: fan speed (desired value)
|
|
62: status valve, LCP
|
|
63: status LCP
|
|
64: temperature difference water temperatures
|
|
65: control temperature 1, LCP
|
|
66: control temperature 2, LCP
|
|
67: condensate pump, duration, LCP
|
|
68: condensate pump, cycles, LCP
|
|
72: total energy*10 (kWh), PSM
|
|
73: total power*10 (kW), PSM
|
|
74: frequency*10 (Hz), PSM
|
|
75: voltage*10 (V), PSM
|
|
76: voltage status, PSM
|
|
77: current*10 (A), PSM
|
|
78: current status, PSM
|
|
79: power*10 (kW) per phase, PSM
|
|
80: energy*10 (kWh) per phase, PSM
|
|
81: temporary energy*10 (kWh) per phase, PSM
|
|
100: temperature sensor, wireless
|
|
101: temperature sensor (combi), wireless
|
|
102: humidity sensor, wireless
|
|
103: access sensor, wireless
|
|
104: user sensor with normally opened contact, wireless
|
|
105: user sensor with normally closed contact, wireless
|
|
106: analog sensor 4..20mA, wireless"
|
|
::= { cmcTcUnit4SensorEntry 2 }
|
|
|
|
|
|
unit4SensorText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each sensor (entry in the table)"
|
|
::= { cmcTcUnit4SensorEntry 3 }
|
|
|
|
unit4SensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
warning(7),
|
|
tooLow(8),
|
|
tooHigh(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the sensor"
|
|
::= { cmcTcUnit4SensorEntry 4 }
|
|
|
|
unit4SensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { cmcTcUnit4SensorEntry 5 }
|
|
|
|
unit4SensorSetHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for high setpoint of sensor"
|
|
::= { cmcTcUnit4SensorEntry 6 }
|
|
|
|
unit4SensorSetLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for low setpoint of sensor"
|
|
::= { cmcTcUnit4SensorEntry 7 }
|
|
|
|
unit4SensorSetWarn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for warning setpoint of sensor,
|
|
also used as fan threshold"
|
|
::= { cmcTcUnit4SensorEntry 8 }
|
|
|
|
-- table END
|
|
|
|
-- Outputs
|
|
cmcTcUnit4NumberOfOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of outputs available on sensor unit 4"
|
|
::= { cmcTcStatusUnit4Outputs 1 }
|
|
|
|
-- table with entry for each output available on this unit
|
|
|
|
cmcTcUnit4OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit4OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of output table"
|
|
::= { cmcTcStatusUnit4Outputs 2 }
|
|
|
|
cmcTcUnit4OutputEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit4OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of output table"
|
|
INDEX { unit4OutputIndex }
|
|
::= { cmcTcUnit4OutputTable 1 }
|
|
|
|
CmcTcUnit4OutputEntry ::=
|
|
SEQUENCE {
|
|
unit4OutputIndex
|
|
INTEGER,
|
|
unit4OutputType
|
|
INTEGER,
|
|
unit4OutputText
|
|
DisplayString,
|
|
unit4OutputStatus
|
|
INTEGER,
|
|
unit4OutputValue
|
|
INTEGER,
|
|
unit4OutputSet
|
|
INTEGER,
|
|
unit4OutputConfig
|
|
INTEGER,
|
|
unit4OutputDelay
|
|
INTEGER,
|
|
unit4OutputTimeoutAction
|
|
INTEGER
|
|
}
|
|
|
|
unit4OutputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of output entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit4NumberOfOutputs."
|
|
::= { cmcTcUnit4OutputEntry 1 }
|
|
|
|
unit4OutputType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail (1),
|
|
failure (2),
|
|
overflow (3),
|
|
doorLock (4),
|
|
univLock1 (5),
|
|
univLock2 (6),
|
|
fan (7),
|
|
fanSpeedContr (8),
|
|
universalOut (9),
|
|
roomLock(10),
|
|
powerOut(11),
|
|
doorLockMaster(12),
|
|
doorLockFRi (13),
|
|
setpoint (14),
|
|
setpointTimax (15),
|
|
hysteresisRCT (16),
|
|
commandRCT (17),
|
|
relayPSM (18),
|
|
setHighPSM (19),
|
|
setLowPSM (20),
|
|
setpointRTT (21),
|
|
setTimaxRTT (22),
|
|
powerOut1(23),
|
|
controlModeLCP (30),
|
|
minFanSpeedLCP (31),
|
|
minDeltaTLCP (32),
|
|
maxDeltaTLCP (33),
|
|
kPLCP (34),
|
|
kILCP (35),
|
|
kDLCP (36),
|
|
flowRateLCP(37),
|
|
cwValueLCP (38),
|
|
deltaTLCP (39),
|
|
ctrModLCP (40),
|
|
voltHighPSM (42),
|
|
voltLowPSM (43),
|
|
ampHighPSM (44),
|
|
ampLowPSM (45),
|
|
commandPSM (46)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of output which is connected to sensor unit 4 to output[unit4OutputIndex]
|
|
1: no output connected
|
|
2: output failure
|
|
3: value overflow
|
|
4: output type 1, door locking TS8,Ergoform
|
|
5: output type 2, universal lock 1, lock with power
|
|
6: output type 3, universal lock 2, unlock with power
|
|
7: output type 4, fan relay
|
|
8: output type 5, fan controlled
|
|
9: output type 6, universal relay output
|
|
10: output type 7, room door lock
|
|
11: output type 8, power output
|
|
12: output type 9, door lock with Master key
|
|
13: output type 10, door lock FR(i)
|
|
14: setpoint (FCS, RTT)
|
|
15: setpoint temperature monitoring (RTT)
|
|
16: hysteresis of setpoint (RCT)
|
|
17: command for remote control of RCT
|
|
18: relay PSM, 1=On, 0=Off
|
|
19: high setpoint current monitoring PSM
|
|
20: low setpoint current monitoring PSM
|
|
21: setpoint temperature RTT
|
|
22: setpoint temperature monitoring RTT
|
|
23: power output 20A
|
|
30: control mode LCP
|
|
31: min fan speed (fan control) LCP
|
|
32: min delta T (fan control) LCP
|
|
33: max delta T (fan control) LCP
|
|
34: PID controller, KP, LCP
|
|
35: PID controller, KI, LCP
|
|
36 PID controller, KD, LCP
|
|
37 flowrate flowmeter, LCP
|
|
38: cw value of water (default: 4187) LCP
|
|
39: deltaT, LCP
|
|
40: control mode, LCP
|
|
42: setpoint high voltage PSM
|
|
43: setpoint low voltage PSM
|
|
44: setpoint high current PSM
|
|
45: setpoint low current PSM
|
|
46: command PSM"
|
|
::= { cmcTcUnit4OutputEntry 2 }
|
|
|
|
|
|
unit4OutputText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each output (entry in the table)"
|
|
::= { cmcTcUnit4OutputEntry 3 }
|
|
|
|
unit4OutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
off(5),
|
|
on(6),
|
|
setOff(7),
|
|
setOn(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the output"
|
|
::= { cmcTcUnit4OutputEntry 4 }
|
|
|
|
unit4OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for output"
|
|
::= { cmcTcUnit4OutputEntry 5 }
|
|
|
|
unit4OutputSet OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (1),
|
|
on (2),
|
|
lock (3),
|
|
unlock (4),
|
|
unlockDelay (5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command for output"
|
|
::= { cmcTcUnit4OutputEntry 6 }
|
|
|
|
unit4OutputConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disRemote (1),
|
|
enRemote (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configuration for output
|
|
1: disable remote control (e.g. keypad)
|
|
2: enable remote control "
|
|
::= { cmcTcUnit4OutputEntry 7 }
|
|
|
|
unit4OutputDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unsigned Value for delay,
|
|
after this time the output will fall into the previous state"
|
|
::= { cmcTcUnit4OutputEntry 8 }
|
|
|
|
unit4OutputTimeoutAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stay (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State for output if timeout (RS422) occurs"
|
|
::= { cmcTcUnit4OutputEntry 9 }
|
|
|
|
|
|
-- Msgs
|
|
|
|
cmcTcUnit4NumberOfMsgs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of alarms that can be created with sensor unit 4"
|
|
::= { cmcTcStatusUnit4Msg 1 }
|
|
|
|
-- table with entry for each alarm available on this unit
|
|
|
|
cmcTcUnit4MsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcUnit4MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of message table"
|
|
::= { cmcTcStatusUnit4Msg 2 }
|
|
|
|
cmcTcUnit4MsgEntry OBJECT-TYPE
|
|
SYNTAX CmcTcUnit4MsgEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of message table"
|
|
INDEX { unit4MsgIndex }
|
|
::= { cmcTcUnit4MsgTable 1 }
|
|
|
|
CmcTcUnit4MsgEntry ::=
|
|
SEQUENCE {
|
|
unit4MsgIndex
|
|
INTEGER,
|
|
unit4MsgText
|
|
DisplayString,
|
|
unit4MsgStatus
|
|
INTEGER,
|
|
unit4MsgRelay
|
|
INTEGER,
|
|
unit4MsgBeeper
|
|
INTEGER,
|
|
unit4MsgTrap1
|
|
INTEGER,
|
|
unit4MsgTrap2
|
|
INTEGER,
|
|
unit4MsgTrap3
|
|
INTEGER,
|
|
unit4MsgTrap4
|
|
INTEGER,
|
|
unit4MsgQuit
|
|
INTEGER
|
|
}
|
|
|
|
unit4MsgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of alarm entries. Its value ranges
|
|
between 1 and the value of cmcTcUnit4NumberOfMsgs."
|
|
::= { cmcTcUnit4MsgEntry 1 }
|
|
|
|
unit4MsgText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each message (entry in the table)"
|
|
::= { cmcTcUnit4MsgEntry 2 }
|
|
|
|
unit4MsgStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
configChanged(2),
|
|
error(3),
|
|
ok(4),
|
|
alarm(5),
|
|
warning(6),
|
|
tooLow(7),
|
|
tooHigh(8),
|
|
setOff(9),
|
|
setOn(10),
|
|
open(11),
|
|
closed(12),
|
|
locked(13),
|
|
unlRemote(14),
|
|
unlReaderKeypad(15),
|
|
unlSNMP(16),
|
|
unlWEB(17),
|
|
unlTimer(18),
|
|
noAccess(19),
|
|
circuit1 (20),
|
|
circuit2 (21),
|
|
lowBatt (22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual message status
|
|
1: not available
|
|
2: configuration has changed (sensor new, changed, lost)
|
|
3: error
|
|
4: OK
|
|
5: alarm, e.g. smoke, vibration...
|
|
6: warning of analog value, value reached warning threshold
|
|
7: analog value too low, value reached low threshold
|
|
8: analog value too high, value reached high threshold
|
|
9: output is set to OFF
|
|
10: output is set to ON
|
|
11: door is open
|
|
12: door is closed
|
|
13: door is locked
|
|
14: door is unlocked by remote input, e.g. external cardreader
|
|
15: door is unlocked by reader or keypad connected to I2C
|
|
16: door is unlocked by SNMP set command (unit1OutputSet)
|
|
17: door is unlocked by WEB
|
|
18: door is unlocked by timer
|
|
19: no access, wrong keycode or cardnumber
|
|
20: orientation of PSM-Unit is circuit 1
|
|
21: orientation of PSM-Unit is circuit 2
|
|
22: battery low, wireless sensor"
|
|
::= { cmcTcUnit4MsgEntry 3 }
|
|
|
|
unit4MsgRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm relay for this alarm
|
|
1: no switching of alarm relay
|
|
2: switching of alarm relay"
|
|
::= { cmcTcUnit4MsgEntry 4 }
|
|
|
|
unit4MsgBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm beeper for this alarm
|
|
1: no audible alarm
|
|
2: audible alarm"
|
|
::= { cmcTcUnit4MsgEntry 5 }
|
|
|
|
unit4MsgTrap1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 1 activated"
|
|
::= { cmcTcUnit4MsgEntry 6 }
|
|
|
|
unit4MsgTrap2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 2 activated"
|
|
::= { cmcTcUnit4MsgEntry 7 }
|
|
|
|
unit4MsgTrap3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 3 activated"
|
|
::= { cmcTcUnit4MsgEntry 8 }
|
|
|
|
unit4MsgTrap4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 4 and Event Logging activated"
|
|
::= { cmcTcUnit4MsgEntry 9 }
|
|
|
|
unit4MsgQuit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
manual (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reset of this alarm
|
|
1: auto
|
|
2: manual, alarm needs confirmation, e. g. with 'C' key"
|
|
::= { cmcTcUnit4MsgEntry 10 }
|
|
-- table END
|
|
|
|
|
|
--Status extension unit
|
|
cmcTcValuesRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm relay for alarm ext. unit(s)
|
|
1: no switching of alarm relay
|
|
2: switching of alarm relay"
|
|
::= { cmcTcStatusExtUnit 1 }
|
|
|
|
cmcTcValuesBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setup of Alarm beeper for alarm ext. unit(s)
|
|
1: no audible alarm
|
|
2: audible alarm"
|
|
::= { cmcTcStatusExtUnit 2 }
|
|
|
|
cmcTcValuesTrap1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 1 activated"
|
|
::= { cmcTcStatusExtUnit 3 }
|
|
|
|
cmcTcValuesTrap2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 2 activated"
|
|
::= { cmcTcStatusExtUnit 4 }
|
|
|
|
cmcTcValuesTrap3 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 3 activated"
|
|
::= { cmcTcStatusExtUnit 5 }
|
|
|
|
cmcTcValuesTrap4 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Trap receiver 4 and Event Logging activated"
|
|
::= { cmcTcStatusExtUnit 6 }
|
|
|
|
cmcTcNumberOfValues OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of values availabel on extension units connected to the CMC"
|
|
::= { cmcTcStatusExtUnit 7 }
|
|
|
|
-- table with entry for each value available on extension units
|
|
cmcTcValuesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of values-table"
|
|
::= { cmcTcStatusExtUnit 8 }
|
|
|
|
cmcTcValuesEntry OBJECT-TYPE
|
|
SYNTAX CmcTcValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of values-table"
|
|
INDEX { valuesIndex }
|
|
::= { cmcTcValuesTable 1 }
|
|
|
|
CmcTcValuesEntry ::=
|
|
SEQUENCE {
|
|
valuesIndex
|
|
INTEGER,
|
|
valuesText
|
|
DisplayString,
|
|
valuesStatus
|
|
INTEGER,
|
|
valuesValue
|
|
INTEGER,
|
|
valuesSetHigh
|
|
INTEGER,
|
|
valuesSetLow
|
|
INTEGER
|
|
}
|
|
|
|
valuesIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of value entries. Its value ranges
|
|
between 1 and the value of cmcTcNumberOfValues."
|
|
::= { cmcTcValuesEntry 1 }
|
|
|
|
|
|
valuesText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..20))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Descriptional text for each value (entry in the table)
|
|
of the extension card"
|
|
::= { cmcTcValuesEntry 2 }
|
|
|
|
valuesStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAvail(1),
|
|
lost(2),
|
|
changed(3),
|
|
ok(4),
|
|
tooLow(5),
|
|
tooHigh(6),
|
|
error(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the value of the extension card"
|
|
::= { cmcTcValuesEntry 3 }
|
|
|
|
valuesValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { cmcTcValuesEntry 4 }
|
|
|
|
valuesSetHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for high setpoint of sensor"
|
|
::= { cmcTcValuesEntry 5 }
|
|
|
|
valuesSetLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value for low setpoint of sensor"
|
|
::= { cmcTcValuesEntry 6 }
|
|
-- table END
|
|
|
|
|
|
--setupGeneral-group
|
|
cmcTcSetTempUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
celsius(1),
|
|
fahrenheit(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit of all temperature values and setpoints, Celsius or Fahrenheit"
|
|
::= { cmcTcSetupGeneral 1 }
|
|
|
|
cmcTcSetBeeper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Audible alarm in CMC-TC unit:
|
|
(2): beeper is on
|
|
(1): beeper is off (general)"
|
|
::= { cmcTcSetupGeneral 2 }
|
|
|
|
|
|
cmcTcQuitRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable acknowledging currently active alarm relay
|
|
(with 'C' on CMC-TC)."
|
|
::= { cmcTcSetupGeneral 3 }
|
|
|
|
|
|
cmcTcLogicRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closeAtAlarm(1),
|
|
openAtAlarm(2),
|
|
off(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Logic of alarm relay:
|
|
(1) Relay will pick up in case of an alarm
|
|
(2) Relay will release in case of an alarm
|
|
(3) Relay off (general)"
|
|
::= { cmcTcSetupGeneral 4 }
|
|
|
|
cmcTcWebAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
viewOnly(1),
|
|
fullAccess(2),
|
|
off(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Web access via HTTP:
|
|
(1) view only
|
|
(2) full Access, read and set
|
|
(3) Web disabled (general)"
|
|
::= { cmcTcSetupGeneral 5 }
|
|
|
|
|
|
-- SetupClock
|
|
cmcTcSetupDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..10))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"actual Date in format DD.MM.YYYY"
|
|
::= { cmcTcSetupGeneral 6 }
|
|
|
|
cmcTcSetupTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)"
|
|
::= { cmcTcSetupGeneral 7 }
|
|
|
|
-- table for timer function
|
|
|
|
cmcTcTimerNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of value-table entries=number of outlets available on this unit"
|
|
::= { cmcTcTimerTable1 1 }
|
|
|
|
cmcTcTimerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Headline of status-table"
|
|
::= { cmcTcTimerTable1 2 }
|
|
|
|
cmcTcTimerEntry OBJECT-TYPE
|
|
SYNTAX CmcTcTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of timer-table"
|
|
INDEX { cmcTcTimerIndex }
|
|
::= { cmcTcTimerTable 1 }
|
|
|
|
CmcTcTimerEntry ::=
|
|
SEQUENCE {
|
|
cmcTcTimerIndex
|
|
INTEGER,
|
|
cmcTcTimerStatus
|
|
INTEGER,
|
|
cmcTcTimerDayOfWeek
|
|
INTEGER,
|
|
cmcTcTimeOn
|
|
DisplayString,
|
|
cmcTcTimeOff
|
|
DisplayString,
|
|
cmcTcTimeControl
|
|
INTEGER,
|
|
cmcTcTimerFunction
|
|
INTEGER
|
|
}
|
|
|
|
cmcTcTimerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the list of timer entries. Its value ranges
|
|
between 1 and the value of cmcTcTimerNumber."
|
|
::= { cmcTcTimerEntry 1 }
|
|
|
|
cmcTcTimerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
switchedOff(1),
|
|
switchedOn(2),
|
|
noTime(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Actual status of the timer"
|
|
::= { cmcTcTimerEntry 2 }
|
|
|
|
cmcTcTimerDayOfWeek OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sun(1),
|
|
mon(2),
|
|
tue(3) ,
|
|
wed(4),
|
|
thu(5),
|
|
fri(6),
|
|
sat(7),
|
|
sat-sun(8),
|
|
mon-fri(9),
|
|
mon-sun(10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of day of week for timer to switch"
|
|
::= { cmcTcTimerEntry 3 }
|
|
|
|
cmcTcTimeOn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to switch on current function,
|
|
Format: HH:MM"
|
|
::= { cmcTcTimerEntry 4 }
|
|
|
|
cmcTcTimeOff OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to switch off current function,
|
|
Format: HH:MM"
|
|
::= { cmcTcTimerEntry 5 }
|
|
|
|
cmcTcTimeControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control via RTC"
|
|
::= { cmcTcTimerEntry 6 }
|
|
|
|
cmcTcTimerFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disKeypad1-1 (1),
|
|
disKeypad2-1 (2),
|
|
disKeypad1-2 (3),
|
|
disKeypad2-2 (4),
|
|
disKeypad1-3 (5),
|
|
disKeypad2-3 (6),
|
|
disKeypad1-4 (7),
|
|
disKeypad2-4 (8),
|
|
unlDoor1-1 (9),
|
|
unlDoor2-1 (10),
|
|
unlDoor1-2 (11),
|
|
unlDoor2-2 (12),
|
|
unlDoor1-3 (13),
|
|
unlDoor2-3 (14),
|
|
unlDoor1-4 (15),
|
|
unlDoor2-5 (16),
|
|
disTrapRec1 (17),
|
|
disTrapRec2 (18),
|
|
disTrapRec3 (19),
|
|
disTrapRec4 (20),
|
|
disSMS (21),
|
|
schedule1 (22),
|
|
schedule2 (23),
|
|
schedule3 (24),
|
|
schedule4 (25),
|
|
disSMS1 (26),
|
|
disSMS2 (27),
|
|
disSMS3 (28),
|
|
disSMS4 (29)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Function which is controlled via timer
|
|
1: unlock via keypad 1 on unit 1 or remote input lock 1 is disabled
|
|
2: unlock via keypad 2 on unit 1 or remote input lock 2 is disabled
|
|
3 unlock via keypad 1 on unit 2 or remote input lock 1 is disabled
|
|
4: unlock via keypad 2 on unit 2 or remote input lock 2 is disabled
|
|
5: unlock via keypad 1 on unit 3 or remote input lock 1 is disabled
|
|
6: unlock via keypad 2 on unit 3 or remote input lock 2 is disabled
|
|
7: unlock via keypad 1 on unit 4 or remote input lock 1 is disabled
|
|
8: unlock via keypad 2 on unit 4 or remote input lock 2 is disabled
|
|
9: Lock of door 1 on unit 1 will be unlocked
|
|
10: Lock of door 2 on unit 1 will be unlocked
|
|
11: Lock of door 1 on unit 2 will be unlocked
|
|
12: Lock of door 2 on unit 2 will be unlocked
|
|
13: Lock of door 1 on unit 3 will be unlocked
|
|
14: Lock of door 2 on unit 3 will be unlocked
|
|
15: Lock of door 1 on unit 4 will be unlocked
|
|
16: Lock of door 2 on unit 4 will be unlocked
|
|
17-20: sending Traps to this Trap receiver will be disabled
|
|
21: sending SMS will be disabled generally
|
|
22-25: Scheduled alarm off
|
|
26-29: sending SMS to phone number 1..4 will be disabled"
|
|
::= { cmcTcTimerEntry 7 }
|
|
|
|
|
|
|
|
--cmcTcTrapTable-group
|
|
|
|
cmcTcTraptableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of trapTable entries. The number of trap-receiver"
|
|
::= { cmcTcTraps 1 }
|
|
|
|
cmcTcTrapTableTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmcTcTrapTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of trap-receiver entries"
|
|
::= { cmcTcTraps 2 }
|
|
|
|
cmcTcTrapTableEntry OBJECT-TYPE
|
|
SYNTAX CmcTcTrapTableEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of trapTable"
|
|
INDEX { trapIndex }
|
|
::= { cmcTcTrapTableTable 1 }
|
|
|
|
CmcTcTrapTableEntry ::=
|
|
SEQUENCE {
|
|
trapIndex
|
|
INTEGER,
|
|
trapStatus
|
|
INTEGER,
|
|
trapIPaddress
|
|
DisplayString
|
|
}
|
|
|
|
trapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index for the trap-receiver-table. Its value ranges between
|
|
1 and the value of traptableNumber "
|
|
::= { cmcTcTrapTableEntry 1 }
|
|
|
|
trapStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
enabled(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable trap receiver"
|
|
::= { cmcTcTrapTableEntry 2 }
|
|
|
|
trapIPaddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..15))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP-address of trap-receiver"
|
|
::= { cmcTcTrapTableEntry 3 }
|
|
|
|
|
|
--cmcTcControl-group (Added in Version 1.1)
|
|
cmcTcQuitUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noQuit(1),
|
|
quit(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Command to quit (acknowledge) alarms of CMC-TC unit.
|
|
Setting to 'quit' (2) will have same result as pressing 'C' on Units.
|
|
Variable is automatically set back to 'noQuit' (1)."
|
|
::= { cmcTcControl 1 }
|
|
|
|
|
|
--Traps
|
|
alarmSensorUnit1 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
unit1MsgIndex, unit1MsgText, unit1MsgStatus, unit1SensorValue }
|
|
DESCRIPTION
|
|
"Alarm of sensor unit 1"
|
|
--
|
|
--#TYPE "Sensor unit alarm"
|
|
--#SUMMARY "Location: %s, Alarm[%s]: %s, Status: %s, from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,6,5,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 1
|
|
|
|
alarmSensorUnit2 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
unit2MsgIndex, unit2MsgText, unit2MsgStatus, unit2SensorValue }
|
|
DESCRIPTION
|
|
"Alarm of sensor unit 2"
|
|
--
|
|
--#TYPE "Sensor unit alarm"
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 2
|
|
|
|
|
|
alarmSensorUnit3 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
unit3MsgIndex, unit3MsgText, unit3MsgStatus, unit3SensorValue }
|
|
DESCRIPTION
|
|
"Alarm of sensor unit 3"
|
|
--
|
|
--#TYPE "Sensor unit alarm"
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 3
|
|
|
|
alarmSensorUnit4 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
unit4MsgIndex, unit4MsgText, unit4MsgStatus, unit4SensorValue }
|
|
DESCRIPTION
|
|
"Alarm of sensor unit 4"
|
|
--
|
|
--#TYPE "Sensor unit alarm"
|
|
--#SUMMARY "Location: %s, Message: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 4
|
|
|
|
|
|
alarmUnit1 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
cmcTcUnit1Text, cmcTcUnit1Status }
|
|
DESCRIPTION
|
|
"Alarm of unit 1"
|
|
--
|
|
--#TYPE "Unit alarm"
|
|
--#SUMMARY "Location: %s, Status: %s, from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 5
|
|
|
|
alarmUnit2 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
cmcTcUnit2Text, cmcTcUnit2Status }
|
|
DESCRIPTION
|
|
"Alarm of unit 2"
|
|
--
|
|
--#TYPE "Unit alarm"
|
|
--#SUMMARY "Location: %s, Status: %s, from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 6
|
|
|
|
|
|
alarmUnit3 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
cmcTcUnit3Text, cmcTcUnit3Status }
|
|
DESCRIPTION
|
|
"Alarm of unit 3"
|
|
--
|
|
--#TYPE "Unit alarm"
|
|
--#SUMMARY "Location: %s, Status: %s, from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 7
|
|
|
|
|
|
alarmUnit4 TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
cmcTcUnit4Text, cmcTcUnit4Status }
|
|
DESCRIPTION
|
|
"Alarm of unit 4"
|
|
--
|
|
--#TYPE "Unit alarm"
|
|
--#SUMMARY "Location: %s, Status: %s, from: %s, contact %s"
|
|
--#ARGUMENTS {3,4,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 8
|
|
|
|
|
|
alarmValues TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysContact, sysName, sysLocation,
|
|
valuesIndex, valuesText, valuesStatus }
|
|
DESCRIPTION
|
|
"Alarm of values measured by external card"
|
|
--
|
|
--#TYPE "Values alarm"
|
|
--#SUMMARY "Location: %s, Message: %s, Status: %s from: %s, contact %s"
|
|
--#ARGUMENTS {3,5,6,2,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 9
|
|
|
|
configChanged TRAP-TYPE
|
|
ENTERPRISE cmcTc
|
|
VARIABLES { sysDescr, sysContact, sysName, sysLocation }
|
|
DESCRIPTION
|
|
"The configuration of the cmc has changed,
|
|
this trap is send if new setup is saved.
|
|
Configuration can be changed by Terminal, Telnet, Web or SNMP
|
|
*** NOT IMPLEMENTED *** "
|
|
--
|
|
--#TYPE "Configuration is changed"
|
|
--#SUMMARY "Location: %s, Configuration of %s, unit %s has changed, contact %s"
|
|
--#ARGUMENTS {3,2,0,1}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 6
|
|
--#STATE OPERATIONAL
|
|
--
|
|
::= 10
|
|
|
|
|
|
END
|
|
|