1586 lines
51 KiB
Plaintext
1586 lines
51 KiB
Plaintext
SAF-INTEGRAW-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Definitions for include by other SAF Tehnika mib modules
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
|
|
TimeTicks
|
|
FROM SNMPv2-SMI -- [RFC2578]
|
|
pointToPoint
|
|
FROM SAF-ENTERPRISE
|
|
safIntegra
|
|
FROM SAF-INTEGRA-MIB
|
|
DisplayString, DateAndTime, PhysAddress
|
|
FROM SNMPv2-TC
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF -- [RFC2580]
|
|
IpAddress
|
|
FROM SNMPv2-SMI -- [RFC2578]
|
|
IANAifType
|
|
FROM IANAifType-MIB;
|
|
|
|
-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
|
|
-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
|
|
-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
|
|
-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
|
|
|
|
integraW MODULE-IDENTITY
|
|
LAST-UPDATED "201605110000Z" -- 11 may 2016
|
|
ORGANIZATION "SAF Tehnika"
|
|
CONTACT-INFO
|
|
"SAF Tehnika technical support
|
|
<techsupport>"
|
|
DESCRIPTION
|
|
"SAF IntegraW radio management base"
|
|
-- Revision history
|
|
REVISION "201605110000Z" -- 11 may 2016
|
|
DESCRIPTION
|
|
"Rx Level State added"
|
|
REVISION "201509170000Z" -- 17 sep 2015
|
|
DESCRIPTION
|
|
"Conformance updated"
|
|
REVISION "201509150000Z" -- 15 sep 2015
|
|
DESCRIPTION
|
|
"Local/remote IP address, mask, gateway OIDs added"
|
|
REVISION "201508120000Z" -- 12 aug 2015
|
|
DESCRIPTION
|
|
"Syntax error fixes"
|
|
REVISION "201507290000Z" -- 29 jul 2015
|
|
DESCRIPTION
|
|
"No modem distortion data is available on Integra-W"
|
|
REVISION "201505290000Z" -- 29 may 2015
|
|
DESCRIPTION
|
|
"No carrier offset and modem temp. data are available on Integra-W"
|
|
REVISION "201505200000Z" -- 20 may 2015
|
|
DESCRIPTION
|
|
"Public Release 1.04.
|
|
Radio PLL status, free physical memory, CPU idle objects added"
|
|
REVISION "201504210000Z" -- 21 apr 2015
|
|
DESCRIPTION
|
|
"Public Release 1.03.
|
|
Added OIDs for modem signal quality and distortion"
|
|
REVISION "201504140000Z" -- 14 apr 2015
|
|
DESCRIPTION
|
|
"Descriptions updated"
|
|
REVISION "201503240000Z" -- 24 mar 2015
|
|
DESCRIPTION
|
|
"Public Release 1.02.
|
|
Removed integraWifLinkUpDownTrapEnable OID"
|
|
REVISION "201502040000Z" -- 04 feb 2015
|
|
DESCRIPTION
|
|
"Syntax fix for integraWmodemRadialMse"
|
|
REVISION "201501200000Z" -- 20 jan 2015
|
|
DESCRIPTION
|
|
"Small typographic error fix"
|
|
REVISION "201501080000Z" -- 08 jan 2015
|
|
DESCRIPTION
|
|
"Public Release 1.01. Syntax & units fixed"
|
|
REVISION "201501060000Z" -- 06 jan 2015
|
|
DESCRIPTION
|
|
"Public Release 1.0"
|
|
::= { safIntegra 2 }
|
|
|
|
|
|
integraWtimestamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Last data update time"
|
|
::= { integraW 1 }
|
|
|
|
-- radio
|
|
|
|
integraWradio OBJECT IDENTIFIER ::= { integraW 2 }
|
|
integraWradioTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Output power of radio transmitter"
|
|
::= { integraWradio 1 }
|
|
|
|
integraWradioTxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Frequency of radio transmitter"
|
|
::= { integraWradio 2 }
|
|
|
|
integraWradioRxLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Level of the received signal"
|
|
::= { integraWradio 3 }
|
|
|
|
integraWradioSide OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
high(1),
|
|
low(2),
|
|
error(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Radio side: Low/High"
|
|
::= { integraWradio 4 }
|
|
|
|
integraWradioTxMute OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
error(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of 'Tx mute'
|
|
1 - Tx is muted,
|
|
2 - Tx is not muted.
|
|
3 - Status information unavailable"
|
|
::= { integraWradio 5 }
|
|
|
|
integraWradioDuplexShift OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilized duplex shift in kHz"
|
|
::= { integraWradio 6 }
|
|
|
|
integraWradioRxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Frequency of radio receiver"
|
|
::= { integraWradio 7 }
|
|
|
|
integraWradioTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Radio module temperature *10 Celsius"
|
|
::= { integraWradio 8 }
|
|
|
|
integraWradioTxMuteDuration OBJECT-TYPE
|
|
SYNTAX Integer32(0..214748364)
|
|
UNITS "s"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time remaning for Tx to be muted in seconds.
|
|
To turn mute on send number of seconds between 10 and MAX.
|
|
To turn mute off send 0.
|
|
GET will retrieve remaining duration for mute or
|
|
0 if Tx mute is turned off."
|
|
::= { integraWradio 9 }
|
|
|
|
--Settable radio parameter range values
|
|
|
|
integraWradioRangesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IntegraWradioRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network interface port status data."
|
|
::= { integraWradio 10 }
|
|
|
|
integraWradioRangeEntry OBJECT-TYPE
|
|
SYNTAX IntegraWradioRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing network physical port status info."
|
|
INDEX { integraWradioRangeEntryIndex }
|
|
::= { integraWradioRangesTable 1 }
|
|
|
|
IntegraWradioRangeEntry ::=
|
|
SEQUENCE {
|
|
integraWradioRangeEntryIndex
|
|
Integer32,
|
|
integraWradioRangeDescr
|
|
DisplayString,
|
|
integraWradioRangeTxPower
|
|
Integer32,
|
|
integraWradioRangeTxFrequency
|
|
Integer32
|
|
}
|
|
|
|
integraWradioRangeEntryIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each range
|
|
entry. Starts with 1 and is equal to a number of all range
|
|
parameters."
|
|
::= { integraWradioRangeEntry 1 }
|
|
|
|
integraWradioRangeDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'Minimal' and 'maximal' labels"
|
|
::= { integraWradioRangeEntry 2 }
|
|
|
|
integraWradioRangeTxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Output power ranges for integraWradio transmitter"
|
|
::= { integraWradioRangeEntry 3 }
|
|
|
|
integraWradioRangeTxFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Frequency ranges for integraWradio transmitter"
|
|
::= { integraWradioRangeEntry 4 }
|
|
|
|
integraWradioPLL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
error(1),
|
|
ok(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "PLL state of local-oscillator generator"
|
|
::= { integraWradio 11 }
|
|
|
|
integraWradioRxLevelState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
low(2),
|
|
high(3),
|
|
error(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Received signal level state"
|
|
::= { integraWradio 12 }
|
|
|
|
-- modem
|
|
|
|
integraWmodem OBJECT IDENTIFIER ::= { integraW 3 }
|
|
-- modem-status
|
|
-- modem-config
|
|
-- misc
|
|
integraWmodemAcquireStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
acquireInProgress(1),
|
|
acquireLocked(2),
|
|
acquireFailed(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This is the current status of modem data acquire
|
|
when queried modem status.
|
|
For detailed info use modemAcquireLastStatusDetails."
|
|
::= { integraWmodem 1 }
|
|
|
|
integraWmodemMse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "dB"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current MSE value (floating point value multiplied by 10)"
|
|
::= { integraWmodem 2 }
|
|
|
|
-- ldpcDecoderStress OBJECT-TYPE
|
|
integraWmodemFecLoad OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
|
|
::= { integraWmodem 3 }
|
|
|
|
integraWmodemSyncLoss OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
unlocked(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modem synchronization status"
|
|
::= { integraWmodem 4 }
|
|
|
|
-- integraWmodemTemperature OBJECT-TYPE
|
|
-- SYNTAX Integer32
|
|
-- UNITS "C"
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION "Modem DSP temperature *10 Celsius"
|
|
-- ::= { integraWmodem 5 }
|
|
|
|
integraWmodemBandwidth OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kHz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Signal bandwidth"
|
|
::= { integraWmodem 6 }
|
|
|
|
integraWmodemModulation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modulation (preferred)"
|
|
::= { integraWmodem 7 }
|
|
|
|
integraWmodemRxModulation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current (actual) Rx Modulation"
|
|
::= { integraWmodem 8 }
|
|
|
|
integraWmodemTxModulation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current (actual) Tx Modulation"
|
|
::= { integraWmodem 9 }
|
|
|
|
integraWmodemRxCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kb/s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Rx ethernet capacity in kilobits per second"
|
|
::= { integraWmodem 10 }
|
|
|
|
integraWmodemTxCapacity OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "kb/s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Tx ethernet capacity in kilobits per second"
|
|
::= { integraWmodem 11 }
|
|
|
|
integraWmodemAcmEngine OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
error(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "ACM engine status"
|
|
::= { integraWmodem 12 }
|
|
|
|
-- integraWmodemCarrierOffset OBJECT-TYPE
|
|
-- SYNTAX Integer32
|
|
-- UNITS "Hz"
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION "Modem carrier offset"
|
|
-- ::= { integraWmodem 13 }
|
|
|
|
integraWmodemSignalQuality OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modem signal quality in %"
|
|
::= { integraWmodem 14 }
|
|
|
|
-- integraWmodemDistortion OBJECT-TYPE
|
|
-- SYNTAX Integer32
|
|
-- UNITS "%"
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION "Modem distortion in %"
|
|
-- ::= { integraWmodem 15 }
|
|
|
|
|
|
-- system
|
|
|
|
integraWsystem OBJECT IDENTIFIER ::= { integraW 4 }
|
|
|
|
integraWsysCPUtemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System CPU temperature *10 Celsius"
|
|
::= { integraWsystem 2 }
|
|
|
|
integraWsysLicenseExpire OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "s"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "License expires after number of seconds.
|
|
In the case of -1, check licenseGenStatus status"
|
|
::= { integraWsystem 3 }
|
|
integraWsysLicenseGenStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(1),
|
|
expired(2),
|
|
unknown(3),
|
|
unlimitedTime(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "License General status."
|
|
::= { integraWsystem 4 }
|
|
|
|
integraWsysPSUvoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "mV"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power voltage in mV"
|
|
::= { integraWsystem 5 }
|
|
|
|
integraWsysPSUcurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "mA"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power current in mA"
|
|
::= { integraWsystem 6 }
|
|
integraWsysPSUpower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "mW"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Power consumption in mW"
|
|
::= { integraWsystem 7 }
|
|
integraWsysBoardTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System temperature *10 Celsius"
|
|
::= { integraWsystem 8 }
|
|
integraWsysFreeMemory OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System free memory *10 %"
|
|
::= { integraWsystem 9 }
|
|
integraWsysCPUidle OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "System CPU idle *10 %"
|
|
::= { integraWsystem 10 }
|
|
|
|
|
|
-- Ethernet
|
|
integraWethernet OBJECT IDENTIFIER ::= { integraW 5 }
|
|
-- Port status
|
|
integraWifStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IntegraWifPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network interface port status data."
|
|
::= { integraWethernet 1 }
|
|
|
|
integraWifPortEntry OBJECT-TYPE
|
|
SYNTAX IntegraWifPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing network physical port status info."
|
|
INDEX { integraWifPortStatIndex }
|
|
::= { integraWifStatusTable 1 }
|
|
|
|
IntegraWifPortEntry ::=
|
|
SEQUENCE {
|
|
integraWifPortStatIndex
|
|
Integer32,
|
|
integraWifPortStatDescr
|
|
DisplayString,
|
|
integraWifPortType
|
|
IANAifType,
|
|
integraWifPortMtu
|
|
Integer32,
|
|
integraWifPortSpeed
|
|
Gauge32,
|
|
integraWifPortPhysAddress
|
|
PhysAddress,
|
|
integraWifPortAdminStatus
|
|
INTEGER,
|
|
integraWifPortOperStatus
|
|
INTEGER,
|
|
integraWifPortLastChange
|
|
TimeTicks,
|
|
integraWifPortAutoneg
|
|
INTEGER,
|
|
integraWifPortDuplex
|
|
INTEGER,
|
|
integraWifPortSyncEthActive
|
|
INTEGER,
|
|
integraWifPortSyncEthPrio
|
|
Integer32,
|
|
integraWifPortFlowControl
|
|
INTEGER
|
|
}
|
|
|
|
integraWifPortStatIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each physical
|
|
network interface. It is recommended that
|
|
values are assigned contiguously starting from 1."
|
|
::= { integraWifPortEntry 1 }
|
|
|
|
integraWifPortStatDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical network interface description.
|
|
LAN1 is electrical, LAN2 and LAN3 are SFP
|
|
and WAN is radio port."
|
|
::= { integraWifPortEntry 2 }
|
|
|
|
integraWifPortType OBJECT-TYPE
|
|
SYNTAX IANAifType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of interface, distinguished according to
|
|
the physical/link protocol(s) immediately `below'
|
|
the network layer in the protocol stack."
|
|
::= { integraWifPortEntry 3 }
|
|
|
|
integraWifPortMtu OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "B"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum transmission unit value in bytes."
|
|
::= { integraWifPortEntry 4 }
|
|
|
|
integraWifPortSpeed OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "bps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link speed in bits per second."
|
|
::= { integraWifPortEntry 5 }
|
|
|
|
integraWifPortPhysAddress OBJECT-TYPE
|
|
SYNTAX PhysAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface's address at the protocol layer
|
|
immediately `below' the network layer in the
|
|
protocol stack. For interfaces which do not have
|
|
such an address (e.g., a serial line), this object
|
|
should contain an octet string of zero length."
|
|
::= { integraWifPortEntry 6 }
|
|
|
|
integraWifPortAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Desired state of network interfaces. Interfaces
|
|
can be enabled(1), disabled(2), unknown(3) (no info received)."
|
|
::= { integraWifPortEntry 7 }
|
|
|
|
integraWifPortOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual state of interfaces. Link can be up(1),
|
|
down(2) or in unknown(3) state."
|
|
::= { integraWifPortEntry 8 }
|
|
|
|
integraWifPortLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter value is always 0 at the moment."
|
|
::= { integraWifPortEntry 9 }
|
|
|
|
integraWifPortAutoneg OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto-negotiation status. Unknown means no info was received."
|
|
::= { integraWifPortEntry 10 }
|
|
|
|
integraWifPortDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
full(1),
|
|
half(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplex status for the interface."
|
|
::= { integraWifPortEntry 11 }
|
|
|
|
integraWifPortSyncEthActive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronous Ethernet status.
|
|
Can be active(1) or inactive(0)."
|
|
::= { integraWifPortEntry 12 }
|
|
|
|
integraWifPortSyncEthPrio OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronous Ethernet priority."
|
|
::= { integraWifPortEntry 13 }
|
|
|
|
integraWifPortFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flow control status."
|
|
::= { integraWifPortEntry 14 }
|
|
|
|
|
|
-- Port statistics
|
|
integraWifStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IntegraWifPortStcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network interface port statistics data."
|
|
::= { integraWethernet 2 }
|
|
|
|
integraWifPortStcEntry OBJECT-TYPE
|
|
SYNTAX IntegraWifPortStcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing network physical port statistics counter data."
|
|
INDEX { integraWifPortStcIndex }
|
|
::= { integraWifStatisticsTable 1 }
|
|
|
|
IntegraWifPortStcEntry ::=
|
|
SEQUENCE {
|
|
integraWifPortStcIndex
|
|
Integer32,
|
|
integraWifPortStcDescr
|
|
DisplayString,
|
|
integraWifTimePassed
|
|
TimeTicks,
|
|
integraWrxDetected
|
|
Counter64,
|
|
integraWrxDropped
|
|
Counter64,
|
|
integraWtxDetected
|
|
Counter64,
|
|
integraWtxDropped
|
|
Counter64,
|
|
integraWrxBytes
|
|
Counter64,
|
|
integraWtxBytes
|
|
Counter64,
|
|
integraWrx64Frames
|
|
Counter64,
|
|
integraWrx65to127Frames
|
|
Counter64,
|
|
integraWrx128to255Frames
|
|
Counter64,
|
|
integraWrx256to511Frames
|
|
Counter64,
|
|
integraWrx512to1023Frames
|
|
Counter64,
|
|
integraWrx1024toMaxFrames
|
|
Counter64,
|
|
integraWrxUsizeFrames
|
|
Counter64,
|
|
integraWrxOsizeFrames
|
|
Counter64,
|
|
integraWtx64Frames
|
|
Counter64,
|
|
integraWtx65to127Frames
|
|
Counter64,
|
|
integraWtx128to255Frames
|
|
Counter64,
|
|
integraWtx256to511Frames
|
|
Counter64,
|
|
integraWtx512to1023Frames
|
|
Counter64,
|
|
integraWtx1024toMaxFrames
|
|
Counter64,
|
|
integraWtxUsizeFrames
|
|
Counter64,
|
|
integraWtxOsizeFrames
|
|
Counter64,
|
|
integraWrxGoodFrames
|
|
Counter64,
|
|
integraWrxErrors
|
|
Counter64,
|
|
integraWrxFifoErr
|
|
Counter64,
|
|
integraWrxCRCErrors
|
|
Counter64,
|
|
integraWrxBcastFrames
|
|
Counter64,
|
|
integraWrxMcastFrames
|
|
Counter64,
|
|
integraWrxCntrlFrames
|
|
Counter64,
|
|
integraWrxLenErrors
|
|
Counter64,
|
|
integraWrxVlanFrames
|
|
Counter64,
|
|
integraWrxPauseFrames
|
|
Counter64,
|
|
integraWrxOpErrors
|
|
Counter64,
|
|
integraWrxFrameErrors
|
|
Counter64,
|
|
integraWtxGoodFrames
|
|
Counter64,
|
|
integraWtxErrors
|
|
Counter64,
|
|
integraWtxFifoErr
|
|
Counter64,
|
|
integraWtxBcastFrames
|
|
Counter64,
|
|
integraWtxMcastFrames
|
|
Counter64,
|
|
integraWtxUrunErrors
|
|
Counter64,
|
|
integraWtxCntrlFrames
|
|
Counter64,
|
|
integraWtxVlanFrames
|
|
Counter64,
|
|
integraWtxPauseFrames
|
|
Counter64,
|
|
integraWtxSingleCollisions
|
|
Counter64,
|
|
integraWtxMultiCollisions
|
|
Counter64,
|
|
integraWtxDeferred
|
|
Counter64,
|
|
integraWtxLateCollisions
|
|
Counter64,
|
|
integraWtxExcessCollisions
|
|
Counter64,
|
|
integraWtxExcessDeferral
|
|
Counter64,
|
|
integraWtxAlignErrors
|
|
Counter64,
|
|
integraWtxCarrierErrors
|
|
Counter64,
|
|
integraWtxCollisions
|
|
Counter64
|
|
}
|
|
|
|
integraWifPortStcIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each physical
|
|
network interface. It is recommended that
|
|
values are assigned contiguously starting from 1."
|
|
::= { integraWifPortStcEntry 1 }
|
|
|
|
integraWifPortStcDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical network interface description.
|
|
LAN1 is electrical, LAN2 and LAN3 are SFP,
|
|
WAN is radio port and MNG is internal management interface."
|
|
::= { integraWifPortStcEntry 2 }
|
|
|
|
integraWifTimePassed OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
UNITS "s/100"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Statistics collection time."
|
|
::= { integraWifPortStcEntry 3 }
|
|
|
|
integraWrxDetected OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Detected ingoing packets counter."
|
|
::= { integraWifPortStcEntry 4 }
|
|
|
|
integraWrxDropped OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dropped ingoing packets counter."
|
|
::= { integraWifPortStcEntry 5 }
|
|
|
|
integraWtxDetected OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Detected outgoing packets counter."
|
|
::= { integraWifPortStcEntry 6 }
|
|
|
|
integraWtxDropped OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dropped outgoing packets counter."
|
|
::= { integraWifPortStcEntry 7 }
|
|
|
|
integraWrxBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "B"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ingoing bytes counter."
|
|
::= { integraWifPortStcEntry 8 }
|
|
|
|
integraWtxBytes OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "B"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outgoing bytes counter."
|
|
::= { integraWifPortStcEntry 9 }
|
|
|
|
integraWrx64Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 10 }
|
|
|
|
integraWrx65to127Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 11 }
|
|
|
|
integraWrx128to255Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 12 }
|
|
|
|
integraWrx256to511Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 13 }
|
|
|
|
integraWrx512to1023Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 14 }
|
|
|
|
integraWrx1024toMaxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 15 }
|
|
|
|
integraWrxUsizeFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 16 }
|
|
|
|
integraWrxOsizeFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 17 }
|
|
|
|
integraWtx64Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 18 }
|
|
|
|
integraWtx65to127Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 19 }
|
|
|
|
integraWtx128to255Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 20 }
|
|
|
|
integraWtx256to511Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 21 }
|
|
|
|
integraWtx512to1023Frames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 22 }
|
|
|
|
integraWtx1024toMaxFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 23 }
|
|
|
|
integraWtxUsizeFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 24 }
|
|
|
|
integraWtxOsizeFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 25 }
|
|
|
|
integraWrxGoodFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 26 }
|
|
|
|
integraWrxErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 27 }
|
|
|
|
integraWrxFifoErr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 28 }
|
|
|
|
integraWrxCRCErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 29 }
|
|
|
|
integraWrxBcastFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 30 }
|
|
|
|
integraWrxMcastFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 31 }
|
|
|
|
integraWrxCntrlFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 32 }
|
|
|
|
integraWrxLenErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 33 }
|
|
|
|
integraWrxVlanFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 34 }
|
|
|
|
integraWrxPauseFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 35 }
|
|
|
|
integraWrxOpErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 36 }
|
|
|
|
integraWrxFrameErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 37 }
|
|
|
|
integraWtxGoodFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 38 }
|
|
|
|
integraWtxErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 39 }
|
|
|
|
integraWtxFifoErr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 40 }
|
|
|
|
integraWtxBcastFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 41 }
|
|
|
|
integraWtxMcastFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 42 }
|
|
|
|
integraWtxUrunErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 43 }
|
|
|
|
integraWtxCntrlFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 44 }
|
|
|
|
integraWtxVlanFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 45 }
|
|
|
|
integraWtxPauseFrames OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frame"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 46 }
|
|
|
|
integraWtxSingleCollisions OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 47 }
|
|
|
|
integraWtxMultiCollisions OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 48 }
|
|
|
|
integraWtxDeferred OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 49 }
|
|
|
|
integraWtxLateCollisions OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 50 }
|
|
|
|
integraWtxExcessCollisions OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 51 }
|
|
|
|
integraWtxExcessDeferral OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 52 }
|
|
|
|
integraWtxAlignErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 53 }
|
|
|
|
integraWtxCarrierErrors OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 54 }
|
|
|
|
integraWtxCollisions OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packet"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { integraWifPortStcEntry 55 }
|
|
|
|
|
|
|
|
-- Configuration applying/saving objects
|
|
|
|
integraWexecuteConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
execute(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object can only be set to 1.
|
|
It initiates new running configuration
|
|
applying using values, that have been set before.
|
|
Setting it when no new changes are available
|
|
will do nothing and return an error.
|
|
GET will return 0 if there were no errors,
|
|
while executing configuration or will return
|
|
a bitmask, that shows which SET requests have failed.
|
|
Those failed requests will be shown bit wise
|
|
from LSB as follows:
|
|
BIT0 radioTxMuteDuration
|
|
BIT1 radioTxFrequency
|
|
BIT2 radioTxPower"
|
|
::= { integraW 6 }
|
|
|
|
integraWneedStore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object shows if there is unsaved,
|
|
but executed (running) configuration.
|
|
Unsaved changes will be lost after
|
|
device reboot. Unsaved entities are shown
|
|
bit wise, starting from LSB as follows:
|
|
BIT0 Aggregation
|
|
BIT1 Event log
|
|
BIT2 Modem
|
|
BIT3 Network
|
|
BIT4 Performance
|
|
BIT5 Radio
|
|
BIT6 SNMP
|
|
BIT7 Synchronous Ethernet
|
|
BIT8 System"
|
|
::= { integraW 7 }
|
|
|
|
integraWstoreConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
store(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object can only be set to 1.
|
|
It initiates saving of running configuration.
|
|
It will only work if there are unsaved,
|
|
but executed (running) changes (configuration).
|
|
Setting it when no new running configuration
|
|
is available will do nothing and return an error."
|
|
::= { integraW 8 }
|
|
|
|
|
|
-- IP settings
|
|
|
|
integraWnetCfg OBJECT IDENTIFIER ::= { integraW 9 }
|
|
|
|
integraWnetCfgIPaddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Local IP address"
|
|
::= { integraWnetCfg 1 }
|
|
|
|
integraWnetCfgIPmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Local IP mask"
|
|
::= { integraWnetCfg 2 }
|
|
|
|
integraWnetCfgIPgateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "IP gateway
|
|
Send '0' or '255.255.255.255' to clear."
|
|
::= { integraWnetCfg 3 }
|
|
|
|
integraWnetCfgRemoteIPaddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Remote IP address"
|
|
::= { integraWnetCfg 4 }
|
|
|
|
|
|
-- Conformance
|
|
|
|
integraWConformance OBJECT IDENTIFIER ::= { integraW 10 }
|
|
integraWCompliances OBJECT IDENTIFIER ::= { integraWConformance 1 }
|
|
|
|
integraWCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "The compliance statement for SNMP engine which
|
|
implements the SAF Tehnika Integra-W device."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
integraWMiscGroup,
|
|
integraWRadioGroup,
|
|
integraWModemGroup,
|
|
integraWSystemGroup,
|
|
integraWEthernetGeneralGroup,
|
|
integraWEthernetMiiPortGroup }
|
|
::= { integraWCompliances 1 }
|
|
integraWGroups OBJECT IDENTIFIER ::= { integraWConformance 2 }
|
|
|
|
integraWMiscGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWtimestamp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "misc data"
|
|
::= { integraWGroups 1 }
|
|
|
|
integraWRadioGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWradioTxPower,
|
|
integraWradioTxFrequency,
|
|
integraWradioRxLevel,
|
|
integraWradioSide,
|
|
integraWradioTxMute,
|
|
integraWradioDuplexShift,
|
|
integraWradioRxFrequency,
|
|
integraWradioTemperature,
|
|
integraWradioTxMuteDuration,
|
|
integraWradioRangeEntryIndex,
|
|
integraWradioRangeDescr,
|
|
integraWradioRangeTxPower,
|
|
integraWradioRangeTxFrequency,
|
|
integraWradioPLL
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Radio group."
|
|
::= { integraWGroups 2 }
|
|
|
|
integraWModemGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWmodemAcquireStatus,
|
|
integraWmodemMse,
|
|
integraWmodemFecLoad,
|
|
integraWmodemSyncLoss,
|
|
integraWmodemBandwidth,
|
|
integraWmodemModulation,
|
|
integraWmodemRxModulation,
|
|
integraWmodemTxModulation,
|
|
integraWmodemRxCapacity,
|
|
integraWmodemTxCapacity,
|
|
integraWmodemAcmEngine,
|
|
integraWmodemSignalQuality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Modem group."
|
|
::= { integraWGroups 3 }
|
|
|
|
integraWSystemGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWsysCPUtemperature,
|
|
integraWsysLicenseExpire,
|
|
integraWsysLicenseGenStatus,
|
|
integraWsysPSUvoltage,
|
|
integraWsysPSUcurrent,
|
|
integraWsysPSUpower,
|
|
integraWsysBoardTemperature,
|
|
integraWsysFreeMemory,
|
|
integraWsysCPUidle,
|
|
integraWexecuteConfig,
|
|
integraWneedStore,
|
|
integraWstoreConfig
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "System group."
|
|
::= { integraWGroups 4 }
|
|
|
|
integraWEthernetGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWifPortStatIndex,
|
|
integraWifPortStatDescr,
|
|
integraWifPortType,
|
|
integraWifPortMtu,
|
|
integraWifPortSpeed,
|
|
integraWifPortPhysAddress,
|
|
integraWifPortAdminStatus,
|
|
integraWifPortOperStatus,
|
|
integraWifPortLastChange,
|
|
integraWifPortAutoneg,
|
|
integraWifPortDuplex,
|
|
integraWifPortSyncEthActive,
|
|
integraWifPortSyncEthPrio,
|
|
integraWifPortFlowControl,
|
|
integraWifPortStcIndex,
|
|
integraWifPortStcDescr,
|
|
integraWifTimePassed,
|
|
integraWnetCfgIPaddress,
|
|
integraWnetCfgIPmask,
|
|
integraWnetCfgIPgateway,
|
|
integraWnetCfgRemoteIPaddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection to objects, providing info applicable to
|
|
all network interfaces."
|
|
::= { integraWGroups 5 }
|
|
|
|
integraWEthernetMiiPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
integraWrxDetected,
|
|
integraWrxDropped,
|
|
integraWtxDetected,
|
|
integraWtxDropped,
|
|
integraWrxBytes,
|
|
integraWtxBytes,
|
|
integraWrx64Frames,
|
|
integraWrx65to127Frames,
|
|
integraWrx128to255Frames,
|
|
integraWrx256to511Frames,
|
|
integraWrx512to1023Frames,
|
|
integraWrx1024toMaxFrames,
|
|
integraWrxUsizeFrames,
|
|
integraWrxOsizeFrames,
|
|
integraWtx64Frames,
|
|
integraWtx65to127Frames,
|
|
integraWtx128to255Frames,
|
|
integraWtx256to511Frames,
|
|
integraWtx512to1023Frames,
|
|
integraWtx1024toMaxFrames,
|
|
integraWtxUsizeFrames,
|
|
integraWtxOsizeFrames,
|
|
integraWrxGoodFrames,
|
|
integraWrxErrors,
|
|
integraWrxFifoErr,
|
|
integraWrxCRCErrors,
|
|
integraWrxBcastFrames,
|
|
integraWrxMcastFrames,
|
|
integraWrxCntrlFrames,
|
|
integraWrxLenErrors,
|
|
integraWrxVlanFrames,
|
|
integraWrxPauseFrames,
|
|
integraWrxOpErrors,
|
|
integraWrxFrameErrors,
|
|
integraWtxGoodFrames,
|
|
integraWtxErrors,
|
|
integraWtxFifoErr,
|
|
integraWtxBcastFrames,
|
|
integraWtxMcastFrames,
|
|
integraWtxUrunErrors,
|
|
integraWtxCntrlFrames,
|
|
integraWtxVlanFrames,
|
|
integraWtxPauseFrames,
|
|
integraWtxSingleCollisions,
|
|
integraWtxMultiCollisions,
|
|
integraWtxDeferred,
|
|
integraWtxLateCollisions,
|
|
integraWtxExcessCollisions,
|
|
integraWtxExcessDeferral,
|
|
integraWtxAlignErrors,
|
|
integraWtxCarrierErrors,
|
|
integraWtxCollisions
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "A collection of objects, providing info applicable
|
|
only to MII group interfaces."
|
|
::= { integraWGroups 6 }
|
|
|
|
END
|