mibs/MIBS/saf/SAF-INTEGRAW-MIB
2023-12-05 12:25:34 +01:00

1586 lines
51 KiB
Plaintext

SAF-INTEGRAW-MIB DEFINITIONS ::= BEGIN
-- Definitions for include by other SAF Tehnika mib modules
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32, Counter64,
TimeTicks
FROM SNMPv2-SMI -- [RFC2578]
pointToPoint
FROM SAF-ENTERPRISE
safIntegra
FROM SAF-INTEGRA-MIB
DisplayString, DateAndTime, PhysAddress
FROM SNMPv2-TC
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF -- [RFC2580]
IpAddress
FROM SNMPv2-SMI -- [RFC2578]
IANAifType
FROM IANAifType-MIB;
-- saf OBJECT IDENTIFIER ::= { enterprises 7571 }
-- microwaveRadio OBJECT IDENTIFIER ::= { tehnika 1 }
-- pointToPoint OBJECT IDENTIFIER ::= { microwaveRadio 1 }
-- safIntegra OBJECT IDENTIFIER ::= { pointToPoint 7 }
integraW MODULE-IDENTITY
LAST-UPDATED "201605110000Z" -- 11 may 2016
ORGANIZATION "SAF Tehnika"
CONTACT-INFO
"SAF Tehnika technical support
<techsupport>"
DESCRIPTION
"SAF IntegraW radio management base"
-- Revision history
REVISION "201605110000Z" -- 11 may 2016
DESCRIPTION
"Rx Level State added"
REVISION "201509170000Z" -- 17 sep 2015
DESCRIPTION
"Conformance updated"
REVISION "201509150000Z" -- 15 sep 2015
DESCRIPTION
"Local/remote IP address, mask, gateway OIDs added"
REVISION "201508120000Z" -- 12 aug 2015
DESCRIPTION
"Syntax error fixes"
REVISION "201507290000Z" -- 29 jul 2015
DESCRIPTION
"No modem distortion data is available on Integra-W"
REVISION "201505290000Z" -- 29 may 2015
DESCRIPTION
"No carrier offset and modem temp. data are available on Integra-W"
REVISION "201505200000Z" -- 20 may 2015
DESCRIPTION
"Public Release 1.04.
Radio PLL status, free physical memory, CPU idle objects added"
REVISION "201504210000Z" -- 21 apr 2015
DESCRIPTION
"Public Release 1.03.
Added OIDs for modem signal quality and distortion"
REVISION "201504140000Z" -- 14 apr 2015
DESCRIPTION
"Descriptions updated"
REVISION "201503240000Z" -- 24 mar 2015
DESCRIPTION
"Public Release 1.02.
Removed integraWifLinkUpDownTrapEnable OID"
REVISION "201502040000Z" -- 04 feb 2015
DESCRIPTION
"Syntax fix for integraWmodemRadialMse"
REVISION "201501200000Z" -- 20 jan 2015
DESCRIPTION
"Small typographic error fix"
REVISION "201501080000Z" -- 08 jan 2015
DESCRIPTION
"Public Release 1.01. Syntax & units fixed"
REVISION "201501060000Z" -- 06 jan 2015
DESCRIPTION
"Public Release 1.0"
::= { safIntegra 2 }
integraWtimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last data update time"
::= { integraW 1 }
-- radio
integraWradio OBJECT IDENTIFIER ::= { integraW 2 }
integraWradioTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Output power of radio transmitter"
::= { integraWradio 1 }
integraWradioTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Frequency of radio transmitter"
::= { integraWradio 2 }
integraWradioRxLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Level of the received signal"
::= { integraWradio 3 }
integraWradioSide OBJECT-TYPE
SYNTAX INTEGER {
high(1),
low(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio side: Low/High"
::= { integraWradio 4 }
integraWradioTxMute OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of 'Tx mute'
1 - Tx is muted,
2 - Tx is not muted.
3 - Status information unavailable"
::= { integraWradio 5 }
integraWradioDuplexShift OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Utilized duplex shift in kHz"
::= { integraWradio 6 }
integraWradioRxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency of radio receiver"
::= { integraWradio 7 }
integraWradioTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Radio module temperature *10 Celsius"
::= { integraWradio 8 }
integraWradioTxMuteDuration OBJECT-TYPE
SYNTAX Integer32(0..214748364)
UNITS "s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time remaning for Tx to be muted in seconds.
To turn mute on send number of seconds between 10 and MAX.
To turn mute off send 0.
GET will retrieve remaining duration for mute or
0 if Tx mute is turned off."
::= { integraWradio 9 }
--Settable radio parameter range values
integraWradioRangesTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWradioRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraWradio 10 }
integraWradioRangeEntry OBJECT-TYPE
SYNTAX IntegraWradioRangeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraWradioRangeEntryIndex }
::= { integraWradioRangesTable 1 }
IntegraWradioRangeEntry ::=
SEQUENCE {
integraWradioRangeEntryIndex
Integer32,
integraWradioRangeDescr
DisplayString,
integraWradioRangeTxPower
Integer32,
integraWradioRangeTxFrequency
Integer32
}
integraWradioRangeEntryIndex OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each range
entry. Starts with 1 and is equal to a number of all range
parameters."
::= { integraWradioRangeEntry 1 }
integraWradioRangeDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"'Minimal' and 'maximal' labels"
::= { integraWradioRangeEntry 2 }
integraWradioRangeTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Output power ranges for integraWradio transmitter"
::= { integraWradioRangeEntry 3 }
integraWradioRangeTxFrequency OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Frequency ranges for integraWradio transmitter"
::= { integraWradioRangeEntry 4 }
integraWradioPLL OBJECT-TYPE
SYNTAX INTEGER {
error(1),
ok(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PLL state of local-oscillator generator"
::= { integraWradio 11 }
integraWradioRxLevelState OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
low(2),
high(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Received signal level state"
::= { integraWradio 12 }
-- modem
integraWmodem OBJECT IDENTIFIER ::= { integraW 3 }
-- modem-status
-- modem-config
-- misc
integraWmodemAcquireStatus OBJECT-TYPE
SYNTAX INTEGER {
acquireInProgress(1),
acquireLocked(2),
acquireFailed(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is the current status of modem data acquire
when queried modem status.
For detailed info use modemAcquireLastStatusDetails."
::= { integraWmodem 1 }
integraWmodemMse OBJECT-TYPE
SYNTAX Integer32
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current MSE value (floating point value multiplied by 10)"
::= { integraWmodem 2 }
-- ldpcDecoderStress OBJECT-TYPE
integraWmodemFecLoad OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Decoder stress or FEC load value (floating point in textual representation)"
::= { integraWmodem 3 }
integraWmodemSyncLoss OBJECT-TYPE
SYNTAX INTEGER {
locked(1),
unlocked(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem synchronization status"
::= { integraWmodem 4 }
-- integraWmodemTemperature OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "C"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem DSP temperature *10 Celsius"
-- ::= { integraWmodem 5 }
integraWmodemBandwidth OBJECT-TYPE
SYNTAX Integer32
UNITS "kHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Signal bandwidth"
::= { integraWmodem 6 }
integraWmodemModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modulation (preferred)"
::= { integraWmodem 7 }
integraWmodemRxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Rx Modulation"
::= { integraWmodem 8 }
integraWmodemTxModulation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current (actual) Tx Modulation"
::= { integraWmodem 9 }
integraWmodemRxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rx ethernet capacity in kilobits per second"
::= { integraWmodem 10 }
integraWmodemTxCapacity OBJECT-TYPE
SYNTAX Integer32
UNITS "kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Tx ethernet capacity in kilobits per second"
::= { integraWmodem 11 }
integraWmodemAcmEngine OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
error(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "ACM engine status"
::= { integraWmodem 12 }
-- integraWmodemCarrierOffset OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "Hz"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem carrier offset"
-- ::= { integraWmodem 13 }
integraWmodemSignalQuality OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Modem signal quality in %"
::= { integraWmodem 14 }
-- integraWmodemDistortion OBJECT-TYPE
-- SYNTAX Integer32
-- UNITS "%"
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION "Modem distortion in %"
-- ::= { integraWmodem 15 }
-- system
integraWsystem OBJECT IDENTIFIER ::= { integraW 4 }
integraWsysCPUtemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU temperature *10 Celsius"
::= { integraWsystem 2 }
integraWsysLicenseExpire OBJECT-TYPE
SYNTAX Gauge32
UNITS "s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License expires after number of seconds.
In the case of -1, check licenseGenStatus status"
::= { integraWsystem 3 }
integraWsysLicenseGenStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(1),
expired(2),
unknown(3),
unlimitedTime(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "License General status."
::= { integraWsystem 4 }
integraWsysPSUvoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "mV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power voltage in mV"
::= { integraWsystem 5 }
integraWsysPSUcurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "mA"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power current in mA"
::= { integraWsystem 6 }
integraWsysPSUpower OBJECT-TYPE
SYNTAX Integer32
UNITS "mW"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Power consumption in mW"
::= { integraWsystem 7 }
integraWsysBoardTemperature OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System temperature *10 Celsius"
::= { integraWsystem 8 }
integraWsysFreeMemory OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System free memory *10 %"
::= { integraWsystem 9 }
integraWsysCPUidle OBJECT-TYPE
SYNTAX Integer32
UNITS "%"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System CPU idle *10 %"
::= { integraWsystem 10 }
-- Ethernet
integraWethernet OBJECT IDENTIFIER ::= { integraW 5 }
-- Port status
integraWifStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port status data."
::= { integraWethernet 1 }
integraWifPortEntry OBJECT-TYPE
SYNTAX IntegraWifPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port status info."
INDEX { integraWifPortStatIndex }
::= { integraWifStatusTable 1 }
IntegraWifPortEntry ::=
SEQUENCE {
integraWifPortStatIndex
Integer32,
integraWifPortStatDescr
DisplayString,
integraWifPortType
IANAifType,
integraWifPortMtu
Integer32,
integraWifPortSpeed
Gauge32,
integraWifPortPhysAddress
PhysAddress,
integraWifPortAdminStatus
INTEGER,
integraWifPortOperStatus
INTEGER,
integraWifPortLastChange
TimeTicks,
integraWifPortAutoneg
INTEGER,
integraWifPortDuplex
INTEGER,
integraWifPortSyncEthActive
INTEGER,
integraWifPortSyncEthPrio
Integer32,
integraWifPortFlowControl
INTEGER
}
integraWifPortStatIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraWifPortEntry 1 }
integraWifPortStatDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP
and WAN is radio port."
::= { integraWifPortEntry 2 }
integraWifPortType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface, distinguished according to
the physical/link protocol(s) immediately `below'
the network layer in the protocol stack."
::= { integraWifPortEntry 3 }
integraWifPortMtu OBJECT-TYPE
SYNTAX Integer32
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum transmission unit value in bytes."
::= { integraWifPortEntry 4 }
integraWifPortSpeed OBJECT-TYPE
SYNTAX Gauge32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link speed in bits per second."
::= { integraWifPortEntry 5 }
integraWifPortPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface's address at the protocol layer
immediately `below' the network layer in the
protocol stack. For interfaces which do not have
such an address (e.g., a serial line), this object
should contain an octet string of zero length."
::= { integraWifPortEntry 6 }
integraWifPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Desired state of network interfaces. Interfaces
can be enabled(1), disabled(2), unknown(3) (no info received)."
::= { integraWifPortEntry 7 }
integraWifPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual state of interfaces. Link can be up(1),
down(2) or in unknown(3) state."
::= { integraWifPortEntry 8 }
integraWifPortLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter value is always 0 at the moment."
::= { integraWifPortEntry 9 }
integraWifPortAutoneg OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Auto-negotiation status. Unknown means no info was received."
::= { integraWifPortEntry 10 }
integraWifPortDuplex OBJECT-TYPE
SYNTAX INTEGER {
full(1),
half(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Duplex status for the interface."
::= { integraWifPortEntry 11 }
integraWifPortSyncEthActive OBJECT-TYPE
SYNTAX INTEGER {
off(0),
on(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet status.
Can be active(1) or inactive(0)."
::= { integraWifPortEntry 12 }
integraWifPortSyncEthPrio OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Synchronous Ethernet priority."
::= { integraWifPortEntry 13 }
integraWifPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Flow control status."
::= { integraWifPortEntry 14 }
-- Port statistics
integraWifStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntegraWifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Network interface port statistics data."
::= { integraWethernet 2 }
integraWifPortStcEntry OBJECT-TYPE
SYNTAX IntegraWifPortStcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing network physical port statistics counter data."
INDEX { integraWifPortStcIndex }
::= { integraWifStatisticsTable 1 }
IntegraWifPortStcEntry ::=
SEQUENCE {
integraWifPortStcIndex
Integer32,
integraWifPortStcDescr
DisplayString,
integraWifTimePassed
TimeTicks,
integraWrxDetected
Counter64,
integraWrxDropped
Counter64,
integraWtxDetected
Counter64,
integraWtxDropped
Counter64,
integraWrxBytes
Counter64,
integraWtxBytes
Counter64,
integraWrx64Frames
Counter64,
integraWrx65to127Frames
Counter64,
integraWrx128to255Frames
Counter64,
integraWrx256to511Frames
Counter64,
integraWrx512to1023Frames
Counter64,
integraWrx1024toMaxFrames
Counter64,
integraWrxUsizeFrames
Counter64,
integraWrxOsizeFrames
Counter64,
integraWtx64Frames
Counter64,
integraWtx65to127Frames
Counter64,
integraWtx128to255Frames
Counter64,
integraWtx256to511Frames
Counter64,
integraWtx512to1023Frames
Counter64,
integraWtx1024toMaxFrames
Counter64,
integraWtxUsizeFrames
Counter64,
integraWtxOsizeFrames
Counter64,
integraWrxGoodFrames
Counter64,
integraWrxErrors
Counter64,
integraWrxFifoErr
Counter64,
integraWrxCRCErrors
Counter64,
integraWrxBcastFrames
Counter64,
integraWrxMcastFrames
Counter64,
integraWrxCntrlFrames
Counter64,
integraWrxLenErrors
Counter64,
integraWrxVlanFrames
Counter64,
integraWrxPauseFrames
Counter64,
integraWrxOpErrors
Counter64,
integraWrxFrameErrors
Counter64,
integraWtxGoodFrames
Counter64,
integraWtxErrors
Counter64,
integraWtxFifoErr
Counter64,
integraWtxBcastFrames
Counter64,
integraWtxMcastFrames
Counter64,
integraWtxUrunErrors
Counter64,
integraWtxCntrlFrames
Counter64,
integraWtxVlanFrames
Counter64,
integraWtxPauseFrames
Counter64,
integraWtxSingleCollisions
Counter64,
integraWtxMultiCollisions
Counter64,
integraWtxDeferred
Counter64,
integraWtxLateCollisions
Counter64,
integraWtxExcessCollisions
Counter64,
integraWtxExcessDeferral
Counter64,
integraWtxAlignErrors
Counter64,
integraWtxCarrierErrors
Counter64,
integraWtxCollisions
Counter64
}
integraWifPortStcIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each physical
network interface. It is recommended that
values are assigned contiguously starting from 1."
::= { integraWifPortStcEntry 1 }
integraWifPortStcDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical network interface description.
LAN1 is electrical, LAN2 and LAN3 are SFP,
WAN is radio port and MNG is internal management interface."
::= { integraWifPortStcEntry 2 }
integraWifTimePassed OBJECT-TYPE
SYNTAX TimeTicks
UNITS "s/100"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Statistics collection time."
::= { integraWifPortStcEntry 3 }
integraWrxDetected OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected ingoing packets counter."
::= { integraWifPortStcEntry 4 }
integraWrxDropped OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dropped ingoing packets counter."
::= { integraWifPortStcEntry 5 }
integraWtxDetected OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected outgoing packets counter."
::= { integraWifPortStcEntry 6 }
integraWtxDropped OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Dropped outgoing packets counter."
::= { integraWifPortStcEntry 7 }
integraWrxBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ingoing bytes counter."
::= { integraWifPortStcEntry 8 }
integraWtxBytes OBJECT-TYPE
SYNTAX Counter64
UNITS "B"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Outgoing bytes counter."
::= { integraWifPortStcEntry 9 }
integraWrx64Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 10 }
integraWrx65to127Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 11 }
integraWrx128to255Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 12 }
integraWrx256to511Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 13 }
integraWrx512to1023Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 14 }
integraWrx1024toMaxFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 15 }
integraWrxUsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 16 }
integraWrxOsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 17 }
integraWtx64Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 18 }
integraWtx65to127Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 19 }
integraWtx128to255Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 20 }
integraWtx256to511Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 21 }
integraWtx512to1023Frames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 22 }
integraWtx1024toMaxFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 23 }
integraWtxUsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 24 }
integraWtxOsizeFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 25 }
integraWrxGoodFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 26 }
integraWrxErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 27 }
integraWrxFifoErr OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 28 }
integraWrxCRCErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 29 }
integraWrxBcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 30 }
integraWrxMcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 31 }
integraWrxCntrlFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 32 }
integraWrxLenErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 33 }
integraWrxVlanFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 34 }
integraWrxPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 35 }
integraWrxOpErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 36 }
integraWrxFrameErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 37 }
integraWtxGoodFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 38 }
integraWtxErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 39 }
integraWtxFifoErr OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 40 }
integraWtxBcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 41 }
integraWtxMcastFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 42 }
integraWtxUrunErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 43 }
integraWtxCntrlFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 44 }
integraWtxVlanFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 45 }
integraWtxPauseFrames OBJECT-TYPE
SYNTAX Counter64
UNITS "frame"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 46 }
integraWtxSingleCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 47 }
integraWtxMultiCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 48 }
integraWtxDeferred OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 49 }
integraWtxLateCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 50 }
integraWtxExcessCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 51 }
integraWtxExcessDeferral OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 52 }
integraWtxAlignErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 53 }
integraWtxCarrierErrors OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 54 }
integraWtxCollisions OBJECT-TYPE
SYNTAX Counter64
UNITS "packet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { integraWifPortStcEntry 55 }
-- Configuration applying/saving objects
integraWexecuteConfig OBJECT-TYPE
SYNTAX INTEGER {
execute(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates new running configuration
applying using values, that have been set before.
Setting it when no new changes are available
will do nothing and return an error.
GET will return 0 if there were no errors,
while executing configuration or will return
a bitmask, that shows which SET requests have failed.
Those failed requests will be shown bit wise
from LSB as follows:
BIT0 radioTxMuteDuration
BIT1 radioTxFrequency
BIT2 radioTxPower"
::= { integraW 6 }
integraWneedStore OBJECT-TYPE
SYNTAX INTEGER {
no(0)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object shows if there is unsaved,
but executed (running) configuration.
Unsaved changes will be lost after
device reboot. Unsaved entities are shown
bit wise, starting from LSB as follows:
BIT0 Aggregation
BIT1 Event log
BIT2 Modem
BIT3 Network
BIT4 Performance
BIT5 Radio
BIT6 SNMP
BIT7 Synchronous Ethernet
BIT8 System"
::= { integraW 7 }
integraWstoreConfig OBJECT-TYPE
SYNTAX INTEGER {
store(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object can only be set to 1.
It initiates saving of running configuration.
It will only work if there are unsaved,
but executed (running) changes (configuration).
Setting it when no new running configuration
is available will do nothing and return an error."
::= { integraW 8 }
-- IP settings
integraWnetCfg OBJECT IDENTIFIER ::= { integraW 9 }
integraWnetCfgIPaddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP address"
::= { integraWnetCfg 1 }
integraWnetCfgIPmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local IP mask"
::= { integraWnetCfg 2 }
integraWnetCfgIPgateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP gateway
Send '0' or '255.255.255.255' to clear."
::= { integraWnetCfg 3 }
integraWnetCfgRemoteIPaddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Remote IP address"
::= { integraWnetCfg 4 }
-- Conformance
integraWConformance OBJECT IDENTIFIER ::= { integraW 10 }
integraWCompliances OBJECT IDENTIFIER ::= { integraWConformance 1 }
integraWCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for SNMP engine which
implements the SAF Tehnika Integra-W device."
MODULE -- this module
MANDATORY-GROUPS {
integraWMiscGroup,
integraWRadioGroup,
integraWModemGroup,
integraWSystemGroup,
integraWEthernetGeneralGroup,
integraWEthernetMiiPortGroup }
::= { integraWCompliances 1 }
integraWGroups OBJECT IDENTIFIER ::= { integraWConformance 2 }
integraWMiscGroup OBJECT-GROUP
OBJECTS {
integraWtimestamp
}
STATUS current
DESCRIPTION "misc data"
::= { integraWGroups 1 }
integraWRadioGroup OBJECT-GROUP
OBJECTS {
integraWradioTxPower,
integraWradioTxFrequency,
integraWradioRxLevel,
integraWradioSide,
integraWradioTxMute,
integraWradioDuplexShift,
integraWradioRxFrequency,
integraWradioTemperature,
integraWradioTxMuteDuration,
integraWradioRangeEntryIndex,
integraWradioRangeDescr,
integraWradioRangeTxPower,
integraWradioRangeTxFrequency,
integraWradioPLL
}
STATUS current
DESCRIPTION "Radio group."
::= { integraWGroups 2 }
integraWModemGroup OBJECT-GROUP
OBJECTS {
integraWmodemAcquireStatus,
integraWmodemMse,
integraWmodemFecLoad,
integraWmodemSyncLoss,
integraWmodemBandwidth,
integraWmodemModulation,
integraWmodemRxModulation,
integraWmodemTxModulation,
integraWmodemRxCapacity,
integraWmodemTxCapacity,
integraWmodemAcmEngine,
integraWmodemSignalQuality
}
STATUS current
DESCRIPTION "Modem group."
::= { integraWGroups 3 }
integraWSystemGroup OBJECT-GROUP
OBJECTS {
integraWsysCPUtemperature,
integraWsysLicenseExpire,
integraWsysLicenseGenStatus,
integraWsysPSUvoltage,
integraWsysPSUcurrent,
integraWsysPSUpower,
integraWsysBoardTemperature,
integraWsysFreeMemory,
integraWsysCPUidle,
integraWexecuteConfig,
integraWneedStore,
integraWstoreConfig
}
STATUS current
DESCRIPTION "System group."
::= { integraWGroups 4 }
integraWEthernetGeneralGroup OBJECT-GROUP
OBJECTS {
integraWifPortStatIndex,
integraWifPortStatDescr,
integraWifPortType,
integraWifPortMtu,
integraWifPortSpeed,
integraWifPortPhysAddress,
integraWifPortAdminStatus,
integraWifPortOperStatus,
integraWifPortLastChange,
integraWifPortAutoneg,
integraWifPortDuplex,
integraWifPortSyncEthActive,
integraWifPortSyncEthPrio,
integraWifPortFlowControl,
integraWifPortStcIndex,
integraWifPortStcDescr,
integraWifTimePassed,
integraWnetCfgIPaddress,
integraWnetCfgIPmask,
integraWnetCfgIPgateway,
integraWnetCfgRemoteIPaddress
}
STATUS current
DESCRIPTION "A collection to objects, providing info applicable to
all network interfaces."
::= { integraWGroups 5 }
integraWEthernetMiiPortGroup OBJECT-GROUP
OBJECTS {
integraWrxDetected,
integraWrxDropped,
integraWtxDetected,
integraWtxDropped,
integraWrxBytes,
integraWtxBytes,
integraWrx64Frames,
integraWrx65to127Frames,
integraWrx128to255Frames,
integraWrx256to511Frames,
integraWrx512to1023Frames,
integraWrx1024toMaxFrames,
integraWrxUsizeFrames,
integraWrxOsizeFrames,
integraWtx64Frames,
integraWtx65to127Frames,
integraWtx128to255Frames,
integraWtx256to511Frames,
integraWtx512to1023Frames,
integraWtx1024toMaxFrames,
integraWtxUsizeFrames,
integraWtxOsizeFrames,
integraWrxGoodFrames,
integraWrxErrors,
integraWrxFifoErr,
integraWrxCRCErrors,
integraWrxBcastFrames,
integraWrxMcastFrames,
integraWrxCntrlFrames,
integraWrxLenErrors,
integraWrxVlanFrames,
integraWrxPauseFrames,
integraWrxOpErrors,
integraWrxFrameErrors,
integraWtxGoodFrames,
integraWtxErrors,
integraWtxFifoErr,
integraWtxBcastFrames,
integraWtxMcastFrames,
integraWtxUrunErrors,
integraWtxCntrlFrames,
integraWtxVlanFrames,
integraWtxPauseFrames,
integraWtxSingleCollisions,
integraWtxMultiCollisions,
integraWtxDeferred,
integraWtxLateCollisions,
integraWtxExcessCollisions,
integraWtxExcessDeferral,
integraWtxAlignErrors,
integraWtxCarrierErrors,
integraWtxCollisions
}
STATUS current
DESCRIPTION "A collection of objects, providing info applicable
only to MII group interfaces."
::= { integraWGroups 6 }