--* SAGEM, IONOS *
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--
|
|
-- Filename: equip
|
|
--
|
|
-- File type: .mib
|
|
--
|
|
-- Description: SNMP source Mib file.
|
|
--
|
|
-- Contains general description and operation for
|
|
-- equipent level.
|
|
--
|
|
--
|
|
-- Version: 19 11 2002
|
|
--
|
|
-- Date(DD MM YYYY): 15 11 2002 last update for IONOS NMS
|
|
--
|
|
-- Contact: D. Mobuchon, F. Bonnevialle
|
|
--
|
|
-- History:
|
|
-- Version: Date: 04 08 98
|
|
-- Version: MIB-P0-301199 Date: 30 11 1999
|
|
-- Version: MIB-P0-05092000 Date: 05 09 2000
|
|
-- Modification de la table des managers
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 25 04 2001
|
|
-- Desc: * Add 7 equipment modification counters
|
|
--
|
|
-- Name: S.LAURENT
|
|
-- Date: 14 06 2002
|
|
-- Desc: * DisplayString is imported from SNMPv2-TC instead of RFC1213
|
|
--
|
|
-- Name: F.Bonnevialle
|
|
-- Date: 15 11 2002
|
|
-- Desc: Modification for SilverCreek Compiler
|
|
--*******************************************************************
|
|
--*******************************************************************
|
|
--* Copyright (c) 2002, SAGEM , All rights reserved. *
|
|
--*******************************************************************
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
-- MIB: EQUIPMENT-MIB
|
|
--*******************************************************************
|
|
EQUIPMENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
--*******************************************************************
|
|
-- IMPORTS
|
|
--*******************************************************************
|
|
|
|
IMPORTS
|
|
sagemDr FROM SAGEM-DR-MIB
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
IpAddress,Counter32 FROM SNMPv2-SMI
|
|
DisplayString FROM SNMPv2-TC;
|
|
-- TRAP-TYPE FROM RFC-1215;
|
|
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
-- OBJECTS
|
|
--*******************************************************************
|
|
|
|
--*******************************************************************
|
|
|
|
equip MODULE-IDENTITY
|
|
LAST-UPDATED "0211150000Z"
|
|
ORGANIZATION "SAGEM/DR Tolbiac Centre"
|
|
CONTACT-INFO " "
|
|
DESCRIPTION
|
|
"
|
|
Modification:
|
|
Date: 15 11 2002
|
|
Description:
|
|
sagemDr replace sagem-dr
|
|
NOTIFICATION-TYPE replace TRAP-TYPE
|
|
|
|
Modification:
|
|
Date: 14 06 2002
|
|
Description: Modification of Imports
|
|
DisplayString is imported from SNMPv2-TC instead of RFC1213
|
|
|
|
Modification:
|
|
Date: 20 12 1999
|
|
Description: Modification of comments
|
|
Modification of bugs
|
|
|
|
Modification:
|
|
Date: 19 11 1999
|
|
Name: sagem-dr, SagemBoolean
|
|
Description: Definition of OID sagem-dr instead of sat
|
|
Definition of data SagemBoolean instead of Boolean
|
|
|
|
Name: communityString
|
|
Description: SIZE(0..20) replaced by SIZE (0..50)
|
|
|
|
|
|
New Object:
|
|
Date: 19 11 1999
|
|
|
|
Name: All *Manager* are new objects
|
|
Description: Manager list that recieves the traps.
|
|
|
|
Name: equipCptModif
|
|
Description: Incremental counter used to manage
|
|
the modifications on the equipment.
|
|
|
|
Name: communityAcces
|
|
Description: new names used
|
|
iONNOS-ANM-Supervisor instead of Set ...
|
|
|
|
Name: trapCommunity
|
|
Description:SIZE(0..20) replaced by SIZE (0..50)
|
|
|
|
Name: equipLoad
|
|
Description: Object is simplified to an OID
|
|
|
|
Name: equipLoadDiagnostic
|
|
Description: A string to help in case of problem
|
|
|
|
Name: transferedItemTable,transferedItem,
|
|
TransferedItem,transferedItemIndex
|
|
transferedItemType,transferedItemVersion
|
|
transferedItemComments
|
|
Description:
|
|
These object are used to manage the download
|
|
and upload of some part of the data; the data
|
|
can be a part of a program, a complete program,
|
|
or a config.
|
|
The transferedItemType is reused in equipLocalFile
|
|
|
|
Name: equipStatusV2
|
|
Description: used by IONOS ANM V2
|
|
|
|
"
|
|
REVISION "9808040000Z"
|
|
DESCRIPTION
|
|
"
|
|
Creation : this MIB module describes equipment level operation such as
|
|
date and time set, restart, reset, community and trap
|
|
management.
|
|
"
|
|
::= { sagemDr 107 }
|
|
|
|
--*******************************************************************
|
|
|
|
SagemBoolean ::= INTEGER { true(1), false(2) }
|
|
IntDateTime ::= INTEGER (0..2147483647)
|
|
Severity ::= INTEGER
|
|
{
|
|
nonAlarmed (1),
|
|
minor (2),
|
|
major (3),
|
|
critical (4),
|
|
warning (5),
|
|
invNonAlarmed (6),
|
|
invMinor(7),
|
|
invMajor(8),
|
|
invCritical(9),
|
|
invWarning(10)
|
|
}
|
|
|
|
|
|
--*******************************************************************
|
|
equipDateTime OBJECT-TYPE
|
|
SYNTAX IntDateTime
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this field is the date and time of the equipment.
|
|
It is the number of seconds since 1st January 1970."
|
|
::= { equip 1 }
|
|
|
|
equipLastModif OBJECT-TYPE
|
|
SYNTAX IntDateTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date and time when the equipment was last modified."
|
|
::= { equip 2 }
|
|
|
|
equipWarmStart OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The equipment make a hot start if this field is set to `true'.
|
|
This operation can only be done by the iONOSANMsupervisor
|
|
or dIRECTACCESSsupervisor.
|
|
The value returns to `false' after the restart."
|
|
::= { equip 3 }
|
|
|
|
equipClearConf OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The equipment resets all its parameters, including those
|
|
stored in non-volatile media storage, if this field is set
|
|
to `true'.
|
|
This command does not apply to mib-2 parameters, like @ip,
|
|
routing table, etc ...
|
|
This operation can only be done by the iONOSANMsupervisor
|
|
or dIRECTACCESSsupervisor.
|
|
The value returns to `false' after the reset.
|
|
This operation is optionnal."
|
|
::= { equip 4 }
|
|
|
|
|
|
--*******************************************************************
|
|
-- Description:
|
|
-- Community
|
|
-- The "communityTable" is used for the habilitation.
|
|
-- It contains a sequense of "CommunityEntry"
|
|
-- The size for the habilitation table is 10 elements for ADR equipement.
|
|
-- A "CommunityEntry" is a sequence:
|
|
-- (communityIndex,communityString,communityAccess)
|
|
-- The different kind of habilitation are:
|
|
-- iONOSANMobserver,
|
|
-- iONOSANMoperator,
|
|
-- iONOSANMsupervisor,
|
|
-- dIRECTACCESSobserver,
|
|
-- dIRECTACCESSoperator,
|
|
-- dIRECTACCESSsupervisor,
|
|
-- The 4 last one are used for the "Add Drop for IP" IPA.
|
|
-- iONOSANMclientobserver,
|
|
-- iONOSANMclientoperator,
|
|
-- dIRECTACCESSclientobserver,
|
|
-- dIRECTACCESSclientoperator.
|
|
|
|
communityNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of community in equipment."
|
|
::= { equip 5 }
|
|
|
|
communityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CommunityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of community in equipment."
|
|
::= { equip 6 }
|
|
|
|
communityEntry OBJECT-TYPE
|
|
SYNTAX CommunityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular community of the equipment."
|
|
INDEX { communityIndex }
|
|
::= { communityTable 1 }
|
|
|
|
CommunityEntry ::=
|
|
SEQUENCE {
|
|
communityIndex INTEGER,
|
|
communityString DisplayString,
|
|
communityAcces INTEGER
|
|
}
|
|
|
|
communityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
community."
|
|
::= { communityEntry 1 }
|
|
|
|
|
|
communityString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique textual string that can be used by a SNMP manager as
|
|
community string. It can be also used as password for other
|
|
configuration like http, not only snmp.
|
|
The table must have at least two entries associated with
|
|
the iONOSANMsupervisor access right (this entry is created by
|
|
equipement at startup with value `secret') and
|
|
dIRECTACCESSsupervisor access right (this entry is
|
|
created by equipement at startup with value 'supervisor') .
|
|
According to equipment implementation, it is possible to
|
|
create other entries associed with lower rights that PDU
|
|
community string can afford (actualy equal if
|
|
IONOSANMsupervisor status is granted).
|
|
If the other access rights are created at startup by the equipment,
|
|
its must use the following values : 'private' for
|
|
'iONOSANMoperator, 'public' for 'iONOSANMobserver',
|
|
'operator' for dIRECTACCESSoperator, 'observer' for
|
|
dIRECTACCESSobserver, and 'client' for the others.
|
|
|
|
All community string can be modified only by
|
|
IONOSANMsupervisor.
|
|
A dIRECTACCESS community string can be modified by
|
|
dIRECTACCESSsupervisor.
|
|
|
|
The reading of a community string gives *** for all
|
|
access rights .
|
|
|
|
An entry may be discarded by setting its community string to
|
|
void string. This should not be used by the administrator or
|
|
he could discard himself "
|
|
|
|
::= { communityEntry 2 }
|
|
|
|
|
|
communityAcces OBJECT-TYPE
|
|
SYNTAX INTEGER {iONOSANMobserver (1),
|
|
iONOSANMoperator(2),
|
|
iONOSANMsupervisor(3),
|
|
dIRECTACCESSobserver (4),
|
|
dIRECTACCESSoperator(5),
|
|
dIRECTACCESSsupervisor(6),
|
|
iONOSANMclientobserver(7),
|
|
iONOSANMclientoperator(8),
|
|
dIRECTACCESSclientobserver(9),
|
|
dIRECTACCESSclientoperator(10)
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
iONOSANMsupervisor(3) access :
|
|
allows all operations including community string
|
|
(community string = password)
|
|
iONOSANMoperator(2) access :
|
|
allows all set operations except write community
|
|
string read or write and also some special operations.
|
|
iONOSANMobserver (1) access :
|
|
allows only get and get_next requests.
|
|
dIRECTACCESSsupervisor(6) access :
|
|
allows all operations EXcluding IONOS ANM community string
|
|
dIRECTACCESSoperator(5) access :
|
|
allows all set operations except write community
|
|
string read or write and also some special operations.
|
|
dIRECTACCESSobserver (4) access :
|
|
allows only get and get_next requests.
|
|
iONOSANMclientoperator(8) access :
|
|
allows only set some special operations
|
|
iONOSANMclientobserver(7) access :
|
|
allows only get and get_next requests for special operations
|
|
dIRECTACCESSclientoperator(10) access :
|
|
allows only set some special operations
|
|
dIRECTACCESSclientobserver(9) access :
|
|
allows only get and get_next requests for special operations
|
|
"
|
|
::= { communityEntry 3 }
|
|
|
|
|
|
--*******************************************************************
|
|
-- Description:
|
|
-- "trapTable": trap's receiver table
|
|
|
|
trapNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of trap receivers description in equipment."
|
|
::= { equip 7 }
|
|
|
|
trapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of trap receivers in equipment."
|
|
::= { equip 8 }
|
|
|
|
trapEntry OBJECT-TYPE
|
|
SYNTAX TrapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular trap of the equipment."
|
|
INDEX { trapIndex }
|
|
::= { trapTable 1 }
|
|
|
|
TrapEntry ::=
|
|
SEQUENCE {
|
|
trapIndex INTEGER,
|
|
trapDestination IpAddress,
|
|
trapCommunity DisplayString
|
|
}
|
|
|
|
trapIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value which identify a particular
|
|
trap receiver.
|
|
The value of index is a constant assigned to an entry at
|
|
equipment design time. "
|
|
::= { trapEntry 1 }
|
|
|
|
trapDestination OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ip address to which the equipment will send the traps.
|
|
Note that the value must be unique along this table.
|
|
An entry may be discarded by setting the IP address to 0.0.0.0
|
|
"
|
|
::= { trapEntry 2 }
|
|
|
|
|
|
trapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
-- It is better to use a size value lower than 10.
|
|
-- The size value 50 is used for the BMX
|
|
"The community string to use when a trap is sent to
|
|
this address. "
|
|
::= { trapEntry 3 }
|
|
|
|
|
|
|
|
--*******************************************************************
|
|
|
|
-- Description:
|
|
-- Up and download for the software and configuration
|
|
--
|
|
equipLoad OBJECT IDENTIFIER ::= { equip 9 }
|
|
|
|
equipLocalFile OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file path suitable for the equipment."
|
|
::= { equipLoad 1 }
|
|
|
|
equipServerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ip adress of tftp serveur from which is read/write
|
|
the file `equipRemoteFile'."
|
|
::= { equipLoad 2 }
|
|
|
|
equipRemoteFile OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The file path to be loaded on/from the equipement."
|
|
::= { equipLoad 3 }
|
|
|
|
equipDirection OBJECT-TYPE
|
|
SYNTAX INTEGER { download (0), upload(1)
|
|
, backupDownload (2), switching (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field selects the direction of data stream.
|
|
When it is set to `backupDownload', only the transfert is done.
|
|
When it is set to `download' the transfert is done and then the
|
|
information transfert is switched in the operational state.
|
|
When it is set to `switching', there is no transfert;
|
|
there is only a switching. "
|
|
::= { equipLoad 4 }
|
|
|
|
equipLoadProceed OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This entry is use to start (set to `true') loading a file
|
|
on/from a equipment which has a tftp client.
|
|
The value of the field remains to `true' until load is
|
|
completed or has been aborted.
|
|
This operation can only be done by the iONOSANMsupervisor
|
|
or dIRECTACCESSsupervisor.
|
|
It may be possible to abort the loading by setting it
|
|
to false.
|
|
After the switching of a new configuration, the equipment
|
|
must increase the value of the variable 'equipCptModif'
|
|
"
|
|
::= { equipLoad 5 }
|
|
|
|
equipLoadDiagnostic OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string used to help in case of trouble."
|
|
::= { equipLoad 6 }
|
|
|
|
equipLoadProtocole OBJECT-TYPE
|
|
SYNTAX INTEGER { ftp (1), tftp (2),
|
|
http (3), telnet (4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protocole used by the equipment for the download"
|
|
::= { equipLoad 7 }
|
|
|
|
|
|
--*******************************************************************
|
|
-- Description:
|
|
-- Delayed up and download for the software and configuration
|
|
--
|
|
-- equipLoadState OBJECT-TYPE
|
|
-- SYNTAX INTEGER { delayedLoad (1), loadRunning (2),
|
|
-- delayedSwitching (3), switchingRunning (4),
|
|
-- loadOK (5), loadNOK (6) ,aborted (7)}
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This field indicates the status of the current load processes valided
|
|
-- by 'equipLoadProceed'.
|
|
-- Remark : a download includes a data transfer (load) from the
|
|
-- server to the equipment and a switching for using the data or the
|
|
-- software transfered . A upload includes only a data transfer from
|
|
-- the equipment to the server
|
|
-- It's optional for the equipment which doesn't realise delayed download "
|
|
-- ::= { equipLoad 8 }
|
|
--
|
|
-- equipLoadDateTime OBJECT-TYPE
|
|
-- SYNTAX IntDateTime
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The value of this field is the date and time of the equipment
|
|
-- at which the load processes valided by
|
|
-- 'equipLoadProceed' must begin .
|
|
-- If this value if equal at 0 or < at the current
|
|
-- time, the load starts immediately.
|
|
-- It is the number of seconds since 1st January 1970."
|
|
-- ::= { equipLoad 9 }
|
|
--
|
|
-- equipSwitchingDateTime OBJECT-TYPE
|
|
-- SYNTAX IntDateTime
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "
|
|
-- The value of this field is the date and time of the equipment
|
|
-- at which the switching processes valided by
|
|
-- 'equipLoadProceed' must begin .If this value if equal at
|
|
-- 0 or < at the current time, the switching starts immediately
|
|
-- (if there isn't load)or immediately after the load (if there is a load).
|
|
-- It is the number of seconds since 1st January 1970.
|
|
-- After the switching of a new configuration, the equipment
|
|
-- must increase the value of the variable 'equipCptModif'
|
|
-- "
|
|
-- ::= { equipLoad 10 }
|
|
--
|
|
|
|
|
|
--*******************************************************************
|
|
-- Description:
|
|
-- These object are used to manage the download
|
|
-- and upload of some part of the data; the data
|
|
-- can be a part of a program, a complete program,
|
|
-- or a config.
|
|
--
|
|
-- The transferedItemType can be:
|
|
-- inactive programName
|
|
-- active programName
|
|
-- inactive"Config"
|
|
-- active"Config"
|
|
-- ALL Program
|
|
-- ALL
|
|
--
|
|
-- The transferedItemType is reused in equipLocalFile
|
|
|
|
|
|
transferedItemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferedItemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of uploaded or downloaded Item from the
|
|
equipment."
|
|
::= { equip 30 }
|
|
|
|
transferedItemEntry OBJECT-TYPE
|
|
SYNTAX TransferedItemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A particular Item transferd from/to the equipment."
|
|
INDEX { transferedItemIndex }
|
|
::= { transferedItemTable 1 }
|
|
|
|
TransferedItemEntry ::=
|
|
SEQUENCE {
|
|
transferedItemIndex INTEGER,
|
|
transferedItemType DisplayString,
|
|
transferedItemVersion DisplayString,
|
|
transferedItemComment DisplayString
|
|
}
|
|
|
|
transferedItemIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { transferedItemEntry 1 }
|
|
|
|
transferedItemType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"used to know what kind of data to transferate,
|
|
mainly programName or config"
|
|
::= { transferedItemEntry 2 }
|
|
|
|
transferedItemVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"for a program, return the software version;
|
|
for a config return the associated software version"
|
|
::= { transferedItemEntry 3 }
|
|
|
|
transferedItemComment OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"give additional information about the tranfered data"
|
|
::= { transferedItemEntry 4 }
|
|
|
|
--*******************************************************************
|
|
-- Description:
|
|
|
|
equipStatus OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field summerizes the status of all equipment objects
|
|
(port, card, ...)
|
|
This variable is polled by IONOS ANM V1
|
|
The 'equipmentStatusTrap' is sent after a GET on this variable.
|
|
equipStatus and equipStatusTrap are only used with V1.
|
|
"
|
|
::= { equip 10 }
|
|
|
|
equipStatusV2 OBJECT-TYPE
|
|
SYNTAX Severity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Replace equipStatus for the v2. For the v1, equipStatus
|
|
in EQUIPMENT-MIB send a trap after been polled;
|
|
For the v2, equipStatus is polled."
|
|
::= { equip 11 }
|
|
|
|
--*******************************************************************
|
|
--* modification counters
|
|
--*******************************************************************
|
|
-- Description:
|
|
-- "equipCptModif":
|
|
-- Incremental counter used to manage the modifications
|
|
-- on the equipment.
|
|
-- Warning:
|
|
-- Replace equipLastModif for the new equipment ADR155c and
|
|
-- the next generation of equipment.
|
|
|
|
equipCptModif OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter for all equipments modifications. It represents
|
|
the sum of the 7 other counters"
|
|
::= { equip 12 }
|
|
|
|
-- Modification counters
|
|
cptModif OBJECT IDENTIFIER ::= { equip 14 }
|
|
|
|
cptSNC OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the SNC modifications."
|
|
::= { cptModif 1 }
|
|
|
|
|
|
cptCnx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the Connexion modifications."
|
|
::= { cptModif 2 }
|
|
|
|
cptMSP OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the MSP modifications."
|
|
::= { cptModif 3 }
|
|
|
|
cptMsSpring OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the MS-SPRING modifications."
|
|
::= { cptModif 4 }
|
|
|
|
cptSynchro OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the Synchro modifications."
|
|
::= { cptModif 5 }
|
|
|
|
cptMngt OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the MNGT modifications (mngt list, password, trap, ...)."
|
|
::= { cptModif 6 }
|
|
|
|
cptNet OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter version for the Network modifications."
|
|
::= { cptModif 7 }
|
|
|
|
|
|
-- equipConfSaveStatus OBJECT-TYPE
|
|
-- SYNTAX SagemBoolean
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "If 'true', this variable indicates that all configuration
|
|
-- modifications are saved in flash memory.
|
|
-- If false, this variable indicates that configuration
|
|
-- modifications are not saved in flash memory. "
|
|
-- ::= { equip 13 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Description:
|
|
-- ACCESS TABLE FILTER
|
|
-- The table is a access filter table that ckeck the IP address of
|
|
-- the SNMP managers.
|
|
|
|
|
|
equipManagerNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of manager = number of IP addresses in the table"
|
|
::= { equip 20 }
|
|
|
|
equipManagerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EquipManagerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table containing Ip Addresses and maximum authorized level"
|
|
::= { equip 21 }
|
|
|
|
equipManagerEntry OBJECT-TYPE
|
|
SYNTAX EquipManagerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry containing IP addresses of managers allowed in R/W."
|
|
INDEX {equipManagerIndex}
|
|
::= {equipManagerTable 1}
|
|
|
|
EquipManagerEntry ::=
|
|
SEQUENCE
|
|
{
|
|
equipManagerIndex INTEGER,
|
|
equipManagerAddress IpAddress,
|
|
equipManagerADM SagemBoolean,
|
|
equipManagerOPR SagemBoolean,
|
|
equipManagerOBS SagemBoolean
|
|
}
|
|
|
|
equipManagerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of equipManagerTable
|
|
There's only 10 values in this table"
|
|
::= {equipManagerEntry 1}
|
|
|
|
equipManagerAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of one of the allowed managers.
|
|
If the table contains only address values which are equal
|
|
to 0.0.0.0, no access filter are done.
|
|
Write the IP address 0.0.0.0 to remove a manager.
|
|
This operation can only be done by the iONOSANMsupervisor.
|
|
"
|
|
::= {equipManagerEntry 2}
|
|
|
|
equipManagerADM OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If 'true', this variable indicates that the manager defined by
|
|
its address can have the Supervisor rigth as maximum level
|
|
The value 'false' is set by the equipment when another level
|
|
is choosen"
|
|
::= {equipManagerEntry 3}
|
|
|
|
equipManagerOPR OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If 'true', this variable indicates that the manager defined by
|
|
its address can have the Operator rigth as maximum level
|
|
The value 'false' is set by the equipment when another level
|
|
is choosen"
|
|
::= {equipManagerEntry 4}
|
|
|
|
equipManagerOBS OBJECT-TYPE
|
|
SYNTAX SagemBoolean
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If 'true', this variable indicates that the manager defined by
|
|
its address can have the Observer rigth as maximum level
|
|
The value 'false' is set by the equipment when another level
|
|
is choosen"
|
|
::= {equipManagerEntry 5}
|
|
|
|
--*******************************************************************
|
|
-- Warning: This Trap is only used for V1
|
|
-- equipStatusTrap TRAP-TYPE
|
|
-- ENTERPRISE equip
|
|
-- VARIABLES { equipStatus }
|
|
-- DESCRIPTION
|
|
-- "This trap indicates the alarm status of the equipment.
|
|
-- Only sent with IONOS ANM V1"
|
|
-- ::= 1
|
|
|
|
equipTraps OBJECT IDENTIFIER ::= { equip 0 }
|
|
|
|
equipStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { equipStatus }
|
|
STATUS current
|
|
DESCRIPTION "This trap indicates the alarm status of the equipment.
|
|
Only sent with IONOS ANM V1"
|
|
REFERENCE ""
|
|
::= { equipTraps 1 }
|
|
END
|