-- This module defines enterprise MIBs for UACs
|
|
--
|
|
-- Copyright (c) 1999-2010, Juniper Networks, Inc.
|
|
-- All rights reserved.
|
|
|
|
NETSCREEN-UAC-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
netscreenUAC
|
|
FROM NETSCREEN-SMI
|
|
Integer32, MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
;
|
|
|
|
netscreenUACMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "201004140000Z" -- Apr 14, 2010
|
|
ORGANIZATION
|
|
"Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
"Customer Support
|
|
|
|
1194 North Mathilda Avenue
|
|
Sunnyvale, California 94089-1206
|
|
USA
|
|
|
|
Tel: 1-800-638-8296
|
|
E-mail: customerservice@juniper.net
|
|
HTTP://www.juniper.net"
|
|
DESCRIPTION
|
|
"This module defines the object that are used to monitor all
|
|
UAC"
|
|
REVISION "201004140000Z" -- Apr 14, 2010
|
|
DESCRIPTION
|
|
"Creation Date"
|
|
::= { netscreenUAC 0 }
|
|
|
|
|
|
nsUACActiveUsers OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active users on this box, base on auth entry from UAC controler"
|
|
::= { netscreenUAC 1 }
|
|
|
|
|
|
NsUACControlerStatusEntry ::= SEQUENCE
|
|
{
|
|
nsUACControlerId Integer32,
|
|
nsUACControlerName DisplayString,
|
|
nsUACControlerHost DisplayString,
|
|
nsUACConnectionStatus Integer32
|
|
}
|
|
|
|
nsUACControlerStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NsUACControlerStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NetScreen UAC controler status table"
|
|
::= { netscreenUAC 2}
|
|
|
|
nsUACControlerStatusEntry OBJECT-TYPE
|
|
SYNTAX NsUACControlerStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in the table holds a set of configuration
|
|
parameters associated with an instance of secure UAC."
|
|
INDEX
|
|
{ nsUACControlerID}
|
|
::= { nsUACControlerStatusTable 1 }
|
|
|
|
nsUACControlerId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for UAC table. Its value ranges between 1 and
|
|
65535 and may not be contiguous. the index has no other
|
|
meaning but a pure index"
|
|
::= { nsUACControlerStatusEntry 1 }
|
|
|
|
nsUACControlerName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secure UAC name."
|
|
::= { nsUACControlerStatusEntry 2 }
|
|
|
|
|
|
nsUACControlerHost OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secure UAC name."
|
|
::= { nsUACControlerStatusEntry 3 }
|
|
|
|
nsUACConnectionStatus OBJECT-TYPE
|
|
SYNTAX Integer32 {
|
|
disconnected(0),
|
|
connected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UAC controler status table"
|
|
::= { nsUACControlerStatusEntry 4 }
|
|
|
|
nsUACGlobalStatus OBJECT-TYPE
|
|
SYNTAX Integer32 {
|
|
disconnected(0),
|
|
connected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To indicate whether there is at least one heathy IC-IE connection"
|
|
::= { netscreenUAC 3 }
|
|
END
|