mibs/MIBS/siae/SIAE-ACM-STATISTICS-MIB
2023-12-05 12:25:34 +01:00

617 lines
21 KiB
Plaintext

-- ----------------------------------------------------------------------------
--
-- SIAE MICROELETTRONICA s.p.a.
--
-- Via Michelangelo Buonarroti, 21
-- 20093 - Cologno Monzese
-- Milano
-- ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------
SIAE-ACM-STATISTICS-MIB
DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Integer32, Unsigned32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString, RowStatus
FROM SNMPv2-TC
siaeMib
FROM SIAE-TREE-MIB
AlarmStatus, AlarmSeverityCode
FROM SIAE-ALARM-MIB;
acmStats MODULE-IDENTITY
LAST-UPDATED "201411050000Z"
ORGANIZATION "SIAE MICROELETTRONICA spa"
CONTACT-INFO
"SIAE MICROELETTONICA s.p.a.
Via Michelangelo Buonarroti, 21
20093 - Cologno Monzese
Milano - ITALY
Phone : +39-02-27325-1
E-mail: tbd@siaemic.com
"
DESCRIPTION
"Adaptive Code Modulation (ACM) Statistics (Performance Monitoring)
"
REVISION "201411050000Z"
DESCRIPTION
"MIB version 01.00.01
- Added ACM profilea 4096 QAM and 4096QAM strong
(changed AcmProfile TEXTUAL-CONVENTION)
"
REVISION "201402110000Z"
DESCRIPTION
"Initial version 01.00.00
"
::= { siaeMib 75 }
----------------------------------------------------------------------------------
-- Textual Conventions
----------------------------------------------------------------------------------
AcmProfile ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"List of supported ACM profiles.
"
SYNTAX INTEGER {
unavailable (1), -- This is a virtual profile needed to
-- create a row in the table of counters
-- in order to count seconds with modem
-- not locked.
downshift (2), -- This is a virtual profile needed to
-- create a row in the table of counters
-- in order to count transitions towards
-- lower profiles.
upshift (3), -- This is a virtual profile needed to
-- create a row in the table of counters
-- in order to count transitions towards
-- upper profiles.
acmBPSKstrong (4),
acmBPSK (5),
acm4QAMstrong (6),
acm4QAM (7),
acm8PSKstrong (8),
acm8PSK (9),
acm16QAMstrong (10),
acm16QAM (11),
acm32QAMstrong (12),
acm32QAM (13),
acm64QAMstrong (14),
acm64QAM (15),
acm128QAMstrong (16),
acm128QAM (17),
acm256QAMstrong (18),
acm256QAM (19),
acm512QAMstrong (20),
acm512QAM (21),
acm1024QAMstrong (22),
acm1024QAM (23),
acm2048QAMstrong (24),
acm2048QAM (25),
acm4096QAMstrong (26),
acm4096QAM (27)
}
----------------------------------------------------------------------------------
-- object identifier inside the module
----------------------------------------------------------------------------------
----------------------------------------------------------------------------------
-- acmStats (PERFORMANCE MONITORING ACM) Group
----------------------------------------------------------------------------------
--
-- The following objects are used to manage the ACM counters.
-- The objects of this group are meaningful only if radioEquipAcmEngineEnable
-- is equal to "enable".
--
----------------------------------------------------------------------------------
------ Beginning --------------------------------------------------------------
acmsMibVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Numerical version of this module.
The string version of this MIB have the following format:
XX.YY.ZZ
so, for example, the value 1 should be interpreted as 00.00.01
and the value 10001 should be interpreted as 01.00.01."
::= {acmStats 1}
--
-- TERMINATION POINT LINK TABLE
--
--
------- The following table contains the records used to manage the P.M.
------- Begin of acmsTpLinkTable
--
acmsTpLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcmsTpLinkRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with ACM Termination Point of the radio links.
This table contains object to activate and deactivate the
buildup of counters.
"
::= {acmStats 2}
acmsTpLinkRecord OBJECT-TYPE
SYNTAX AcmsTpLinkRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of acmsTpLinkTable.
"
INDEX {acmsTpLinkId, acmsTpLinkPolId}
::= {acmsTpLinkTable 1}
AcmsTpLinkRecord ::=
SEQUENCE {
acmsTpLinkId Integer32,
acmsTpLinkPolId Integer32,
acmsTpLinkStartStop INTEGER,
acmsTpLinkLabel DisplayString,
acmsTpLinkRowStatus RowStatus
}
acmsTpLinkId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the Radio link.
"
::= {acmsTpLinkRecord 1}
acmsTpLinkPolId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the Radio link polarization for XPIC
configuration. In non XPIC link this object should be 1.
"
::= {acmsTpLinkRecord 2}
acmsTpLinkStartStop OBJECT-TYPE
SYNTAX INTEGER {
start (1),
stop (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to start and to stop the statistic
(Perfomance Monitoring) counter evaluation.
"
DEFVAL {stop}
::= {acmsTpLinkRecord 3}
acmsTpLinkLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string used to identify the ACM Termination Point.
"
::= {acmsTpLinkRecord 4}
acmsTpLinkRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of acmsTpLinkTable.
When set to notInService, associated acmsTpProfileTable
rows may be added, deleted and modified.
When an attempt is made to set acmsTpLinkRowStatus to
active, there is at least a row in acmsTpProfileTable with
first index equal to acmsTpLinkId. Otherwise, the error
inconsistentValue is returned to the set attempt.
The creation of a row in this table, creates a row with the
same index in of acmsTpMaintTable.
The deletion of a row in this table, deletes a row with the
same index in of acmsTpMaintTable.
If this object is set to destroy, must not be no rows in
acmsTpProfileTable associated by acmsTpLinkId to the row
that is being deleted, otherwise, the error inconsistentValue
is returned to the set attempt. Hence, profile instances must
be deleted before this link instance.
"
::= {acmsTpLinkRecord 5}
--
------- End of acmsTpLinkTable
--
-- PROFILE TABLE
--
------- Begin of acmsTpProfileTable
--
acmsTpProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcmsTpProfileRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM Termination Point Thresholds Class table.
Table with AcmsTpProfileRecord records.
This table contains alarms and related thresholds to notify them
within a specific time interval.
"
::= {acmStats 3}
acmsTpProfileRecord OBJECT-TYPE
SYNTAX AcmsTpProfileRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of acmsTpLinkTable.
Several instances (a instance for each ACM profile supported by
the radio system) of this record is created on creation of
acmsTpLinkTable.
"
INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId}
::= {acmsTpProfileTable 1}
AcmsTpProfileRecord ::=
SEQUENCE {
acmsTpProfileId AcmProfile,
acmsTpProfile15mAlarm AlarmStatus,
acmsTpProfile24hAlarm AlarmStatus,
acmsTpProfile15mThreshold Integer32,
acmsTpProfile24hThreshold Integer32,
acmsTpProfileRowStatus RowStatus
}
acmsTpProfileId OBJECT-TYPE
SYNTAX AcmProfile
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object identifies the ACM profile of the radio system.
"
::= {acmsTpProfileRecord 1}
acmsTpProfile15mAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If acmsCounteValue crosses the threshold acmsTpProfile15mThreshold,
this alarm is notified.
"
::= {acmsTpProfileRecord 2}
acmsTpProfile24hAlarm OBJECT-TYPE
SYNTAX AlarmStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If acmsCounteValue crosses the threshold acmsTpProfile24hThreshold,
this alarm is notified.
"
::= {acmsTpProfileRecord 3}
acmsTpProfile15mThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a 15 minutes interval to set
acmsTpProfile15mAlarm. The special value 0 turn off the alarm.
For downshift and upshift profiles, this threshold reports
the number of times a profile must be changed within a 15 minutes
interval to set acmsTpProfile15mAlarm.
"
::= {acmsTpProfileRecord 4}
acmsTpProfile24hThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Number of seconds within a 24 hours interval to set
acmsTpProfile24hAlarm. The special value 0 turn off the alarm.
For the profiles downshift and upshift, this threshold reports
the number of times a profile must be changed within a 24 hours
interval to set acmsTpProfile24hAlarm.
"
::= {acmsTpProfileRecord 5}
acmsTpProfileRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Status of this row of acmsTpProfileTable.
A row in the acmsTpProfileTable may not be created,
deleted, set to notInService or otherwise modified
if the there is no a row in acmsTpProfileTable with the
same acmsTpLinkId and the associated acmsTpLinkRowStatus
object is equal to active. However, if the acmsTpLinkRowStatus
object is equal to notInService, a row may be created, deleted
or modified. In other words, a profile may not be added,
deleted or modified if the ACM statistics of a radio link
is active.
The creation on a row in this table, creates a row with the same
index in of acmsProfileCounterTable.
If this object is set to destroy, the associated instance
of acmsProfileCounterTable will also be deleted by this action.
"
::= {acmsTpProfileRecord 6}
--
-- MAINTENANCE TABLE
--
------- Begin of acmsTpMaintTable
--
acmsTpMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcmsTpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with Command for maintenance of Termination Point.
Objects in this table is not persistent.
"
::= {acmStats 4}
acmsTpMaintRecord OBJECT-TYPE
SYNTAX AcmsTpMaintRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ACM Termination Point Maintenance record.
An Instance of this record is created on creation of
acmsTpLinkTable.
"
INDEX {acmsTpLinkId, acmsTpLinkPolId}
::= {acmsTpMaintTable 1}
AcmsTpMaintRecord ::=
SEQUENCE {
acmsTpMaintCounterClear INTEGER,
acmsTpMaintAlarmClear INTEGER
}
acmsTpMaintCounterClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the statistic (Perfomance Monitoring)
counters.
"
::= {acmsTpMaintRecord 1}
acmsTpMaintAlarmClear OBJECT-TYPE
SYNTAX INTEGER {
notActive (0),
clear (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to clear the threshold cross alarms.
"
::= {acmsTpMaintRecord 2}
--
------- End of acmsTpMaintTable
--
-- COUNTERS TABLE
--
------- Begin of acmsBlockTable
--
acmsIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcmsIntervalRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with records of block.
"
::= {acmStats 5}
acmsIntervalRecord OBJECT-TYPE
SYNTAX AcmsIntervalRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of acmsBlockTable.
There is an entry in acmsBlockTable for each radio link.
Several (up to 19) instances of this record are created since
the first time that acmsTpLinkStartStop becomes start.
"
INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsIntervalId}
::= {acmsIntervalTable 1}
AcmsIntervalRecord ::=
SEQUENCE {
acmsIntervalId INTEGER,
acmsIntervalType INTEGER,
acmsIntervalStatus INTEGER,
acmsIntervalTimeStamp Unsigned32
}
acmsIntervalId OBJECT-TYPE
SYNTAX INTEGER (1..19)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies time intervals according to the
following code:
(1) Current Daily counters
(2) Daily counters of the day before
(3) Current a day counters
(4) a day interval N. 1
(The most recently completed 15 minute interval)
...
(19) a day interval N. 16
(The oldest day counters - 4 hours ago).
The interval identified by 4 is the most recently completed 15
minute interval, and the interval identified by N is the interval
immediately preceding the one identified by N-1.
"
::= {acmsIntervalRecord 1}
acmsIntervalType OBJECT-TYPE
SYNTAX INTEGER {
daily (1),
fifteen-min (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the counter interval: it can describe a daily block
counter or a counter related to a 15 minutes interval.
"
::= {acmsIntervalRecord 2}
acmsIntervalStatus OBJECT-TYPE
SYNTAX INTEGER {
meaningless (1),
meaningfull (2),
incomplete (3),
dummy (4),
lost (5),
restarted (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Interval status.
"
::= {acmsIntervalRecord 3}
acmsIntervalTimeStamp OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object is the time when the performance record is closed.
The time is shown as the number of seconds since January 1, 1970
"
::= {acmsIntervalRecord 4}
--
------- End of acmsLinkBlockTable
------- The following table contains the records with the counters used to monitor
------- the ACM profile (modulation) active on the transmitted frame
------- Begin of acmsProfileCounterTable
--
acmsProfileCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcmsCounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table with records of ACM statistics counters.
"
::= {acmStats 6}
acmsProfileCounterRecord OBJECT-TYPE
SYNTAX AcmsCounterRecord
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry of acmsProfileCounterTable.
There is an entry in acmsProfileCounterTable for each profile
of each radio link.
Several (up to 19) instances of this record are created since
the first time that acmsTpLinkStartStop becomes start.
"
INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId, acmsIntervalId}
::= {acmsProfileCounterTable 1}
AcmsCounterRecord ::=
SEQUENCE {
acmsProfileCounterValue Counter32
}
acmsProfileCounterValue OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"When index acmsTpProfileId is downshift, this object counts the
number of times that the active profile is moved to a lower one.
When index acmsTpProfileId is upshift, this object counts the
number of times that the active profile is moved to an upper one.
When index acmsTpProfileId is unavailable, this object counts
the number of seconds in which the modem is not locked.
For all other values of acmsTpProfileId the object counts the
number of seconds for which the rx profile relative to this row
of the table has been active.
"
::= {acmsProfileCounterRecord 1}
--
------- End of acmsProfileCounterTable
--
------- The following objects are common to all radio branches.
--
acmsTpProfile15mAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the acmsTpProfile15mAlarm
and enables/disables the trap generation on status change event.
"
DEFVAL {majorTrapEnable}
::= {acmStats 7}
acmsTpProfile24hAlarmSeverityCode OBJECT-TYPE
SYNTAX AlarmSeverityCode
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define the severity associated to the acmsTpProfile24hAlarm
and enables/disables the trap generation on status change event.
"
DEFVAL {majorTrapEnable}
::= {acmStats 8}
------ End group -----------------------------------------------------------------
END