-- SIAE MICROELETTRONICA s.p.a.
|
|
--
|
|
-- Via Michelangelo Buonarroti, 21
|
|
-- 20093 - Cologno Monzese
|
|
-- Milano
|
|
-- ITALY
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
SIAE-PMG828-MIB
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
Counter32, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DisplayString, RowStatus
|
|
FROM SNMPv2-TC
|
|
siaeMib
|
|
FROM SIAE-TREE-MIB
|
|
AlarmStatus, AlarmSeverityCode
|
|
FROM SIAE-ALARM-MIB;
|
|
|
|
pmG828 MODULE-IDENTITY
|
|
LAST-UPDATED "201410070000Z"
|
|
ORGANIZATION "SIAE MICROELETTRONICA spa"
|
|
CONTACT-INFO
|
|
"SIAE MICROELETTONICA s.p.a.
|
|
Via Michelangelo Buonarroti, 21
|
|
20093 - Cologno Monzese
|
|
Milano - ITALY
|
|
Phone : +39-02-27325-1
|
|
E-mail: tbd@siaemic.com
|
|
"
|
|
DESCRIPTION
|
|
"Perforfamce Monitoring according to ITU-T G.829 for Radio Link
|
|
and E1 Tributaries
|
|
"
|
|
REVISION "201410070000Z"
|
|
DESCRIPTION
|
|
"Changed MAX-ACCESS caluse of some object of pmG828TpClassTable
|
|
from read-write to read-create
|
|
"
|
|
REVISION "201402030000Z"
|
|
DESCRIPTION
|
|
"Improved description of pmG828MibVersion
|
|
"
|
|
REVISION "201304160000Z"
|
|
DESCRIPTION
|
|
"Initial version 01.00.00
|
|
"
|
|
::= { siaeMib 11 }
|
|
|
|
----------------------------------------------------------------------------------
|
|
-- object identifier inside the module
|
|
----------------------------------------------------------------------------------
|
|
|
|
----------------------------------------------------------------------------------
|
|
-- pmG828 (PDH PERFORMANCE MONITORING G.828) GROUP
|
|
----------------------------------------------------------------------------------
|
|
--
|
|
-- The following objects are used to manage the Pdh G.828 Performance Monitoring
|
|
-- function.
|
|
--
|
|
----------------------------------------------------------------------------------
|
|
|
|
------ Beginning --------------------------------------------------------------
|
|
|
|
--
|
|
------- The following table contains the records with the counters used to evaluate
|
|
------- the Performance Monitoring of the radio according to G.828 specification.
|
|
------- Begin of pmG828CounterTable
|
|
--
|
|
pmG828MibVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numerical version of this module.
|
|
The string version of this MIB have the following format:
|
|
XX.YY.ZZ
|
|
so, for example, the value 1 should be interpreted as 00.00.01
|
|
and the value 10001 should be interpreted as 01.00.01."
|
|
DEFVAL {1}
|
|
::= {pmG828 1}
|
|
|
|
pmG828CounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmG828CounterRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with PmG828 records: one record for 1+0 configuration and two
|
|
record for 1+1 configuration."
|
|
::= {pmG828 2}
|
|
|
|
pmG828CounterRecord OBJECT-TYPE
|
|
SYNTAX PmG828CounterRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmG828Counter record."
|
|
INDEX {pmG828TPointId, pmG828CounterBlockId}
|
|
::= {pmG828CounterTable 1}
|
|
|
|
PmG828CounterRecord ::=
|
|
SEQUENCE {
|
|
pmG828TPointId Integer32,
|
|
pmG828CounterBlockId Integer32,
|
|
pmG828CounterBlockType INTEGER,
|
|
pmG828CounterBlockStatus INTEGER,
|
|
pmG828CounterTimeStamp Unsigned32,
|
|
pmG828BBECounter Counter32,
|
|
pmG828ESCounter Counter32,
|
|
pmG828SESCounter Counter32,
|
|
pmG828UASCounter Counter32,
|
|
pmG828SEPCounter Counter32
|
|
}
|
|
|
|
pmG828TPointId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the Termination Point."
|
|
::= {pmG828CounterRecord 1}
|
|
|
|
pmG828CounterBlockId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the counters block and the counter type
|
|
according to the following code:
|
|
1 Current Daily counters
|
|
2 Daily counters (Day before counters)
|
|
3 Current 15 minutes counters
|
|
4 15 minutes counters N. 1 (The most recent 15 minutes counters)
|
|
..............................................
|
|
n 15 minutes counters N. n
|
|
20 15 minutes counters N.16(The oldest 15 min.counters 4 hours before)."
|
|
::= {pmG828CounterRecord 2}
|
|
|
|
pmG828CounterBlockType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
daily (1),
|
|
fifteenMin (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the counter block."
|
|
::= {pmG828CounterRecord 3}
|
|
|
|
pmG828CounterBlockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
meaningless (1),
|
|
meaningfull (2),
|
|
incomplete (3),
|
|
dummy (4),
|
|
lost (5),
|
|
restarted (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the block counter."
|
|
::= {pmG828CounterRecord 4}
|
|
|
|
pmG828CounterTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object is the time when the performance record is closed reported
|
|
as the second number since 1-Gen-1970."
|
|
::= {pmG828CounterRecord 5}
|
|
|
|
pmG828BBECounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G828 BBE counter."
|
|
::= {pmG828CounterRecord 6}
|
|
|
|
pmG828ESCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G828 Es counter."
|
|
::= {pmG828CounterRecord 7}
|
|
|
|
pmG828SESCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G828 SES counter."
|
|
::= {pmG828CounterRecord 8}
|
|
|
|
pmG828UASCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G828 UAS counter."
|
|
::= {pmG828CounterRecord 9}
|
|
|
|
pmG828SEPCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G828 SEP counter."
|
|
::= {pmG828CounterRecord 10}
|
|
|
|
--
|
|
------- End of pmG828CounterTable
|
|
|
|
--
|
|
------- The following table contains the records used to manage the P.M. on both
|
|
------- radio branch and the threshold cross alarms
|
|
------- Begin of pmG828TpClassTable
|
|
--
|
|
pmG828TpClassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmG828TpClassRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with PmG828TpClass records: one record for 1+0 configuration and
|
|
two record for 1+1 configuration."
|
|
::= {pmG828 3}
|
|
|
|
pmG828TpClassRecord OBJECT-TYPE
|
|
SYNTAX PmG828TpClassRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmG828TpClass record."
|
|
INDEX {pmG828TpClassId}
|
|
::= {pmG828TpClassTable 1}
|
|
|
|
PmG828TpClassRecord ::=
|
|
SEQUENCE {
|
|
pmG828TpClassId Integer32,
|
|
pmG828TpClassStartStop INTEGER,
|
|
pmG828TpClassLabel DisplayString,
|
|
pmG828TpClassTimeStamp Unsigned32,
|
|
pmG828TpClass15MEsAlarm AlarmStatus,
|
|
pmG828TpClass15MSesAlarm AlarmStatus,
|
|
pmG828TpClass15MSepAlarm AlarmStatus,
|
|
pmG828TpClass24HEsAlarm AlarmStatus,
|
|
pmG828TpClass24HSesAlarm AlarmStatus,
|
|
pmG828TpClass24HSepAlarm AlarmStatus,
|
|
pmG828TpClassUasAlarm AlarmStatus,
|
|
pmG828TpClass15MEsThreshold Integer32,
|
|
pmG828TpClass15MSesThreshold Integer32,
|
|
pmG828TpClass15MSepThreshold Integer32,
|
|
pmG828TpClass24HEsThreshold Integer32,
|
|
pmG828TpClass24HSesThreshold Integer32,
|
|
pmG828TpClass24HSepThreshold Integer32,
|
|
pmG828TpClassRowStatus RowStatus
|
|
}
|
|
|
|
pmG828TpClassId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the Termination Point."
|
|
::= {pmG828TpClassRecord 1}
|
|
|
|
pmG828TpClassStartStop OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
start (1),
|
|
stop (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to start and to stop the Perfomance Monitoring
|
|
counter evaluation."
|
|
::= {pmG828TpClassRecord 2}
|
|
|
|
pmG828TpClassLabel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ASCII string used to identify the Tp class:
|
|
for example:
|
|
pmG828TpClassBranchId = 1 label = Radio 1
|
|
pmG828TpClassBranchId = 2 label = Radio 2
|
|
pmG828TpClassBranchId = 3 label = Radio(switched)
|
|
pmG828TpClassBranchId = 4 label = Trib E1 line side
|
|
pmG828TpClassBranchId = 5 label = Trib E1 radio side."
|
|
::= {pmG828TpClassRecord 3}
|
|
|
|
pmG828TpClassTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= {pmG828TpClassRecord 4}
|
|
|
|
pmG828TpClass15MEsAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes ES threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 5}
|
|
|
|
pmG828TpClass15MSesAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes SES threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 6}
|
|
|
|
pmG828TpClass15MSepAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 minutes SEP threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 7}
|
|
|
|
pmG828TpClass24HEsAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily ES threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 8}
|
|
|
|
pmG828TpClass24HSesAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily SES threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 9}
|
|
|
|
pmG828TpClass24HSepAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daily SEP threshold cross alarm with associated severity."
|
|
::= {pmG828TpClassRecord 10}
|
|
|
|
pmG828TpClassUasAlarm OBJECT-TYPE
|
|
SYNTAX AlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UAS alarm with associated severity."
|
|
::= {pmG828TpClassRecord 11}
|
|
|
|
pmG828TpClass15MEsThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of ES within 15 minutes to set pmG828TpClass15MEsAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 12}
|
|
|
|
pmG828TpClass15MSesThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SES within 15 minutes to set pmG828TpClass15MSesAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 13}
|
|
|
|
pmG828TpClass15MSepThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SEP within 15 minutes to set pmG828TpClass15MSepAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 14}
|
|
|
|
pmG828TpClass24HEsThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of ES within one day to set pmG828TpClass24HEsAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 15}
|
|
|
|
pmG828TpClass24HSesThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SES within one day to set pmG828TpClass24HSesAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 16}
|
|
|
|
pmG828TpClass24HSepThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SEP within one day to set pmG828TpClass24HSepAlarm
|
|
(zero value disables the alarm)."
|
|
DEFVAL {0}
|
|
::= {pmG828TpClassRecord 17}
|
|
|
|
pmG828TpClassRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of this row of pmRxPwrTpClass.
|
|
"
|
|
::= {pmG828TpClassRecord 18}
|
|
|
|
--
|
|
------- End of pmG828TpClassTable
|
|
|
|
--
|
|
-- MAINTENANCE TABLE
|
|
--
|
|
|
|
------- Begin of pmG828TpMaintTable
|
|
--
|
|
pmG828TpMaintTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmG828TpMaintRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table with Command for maintenance of Termination Point.
|
|
Objects in this table is not persistent. An Instance of this
|
|
table is created on creation of pmG828TpClassTable"
|
|
::= {pmG828 4}
|
|
|
|
pmG828TpMaintRecord OBJECT-TYPE
|
|
SYNTAX PmG828TpMaintRecord
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PmG828 Termination Point Maintenance record."
|
|
INDEX {pmG828TpClassId}
|
|
::= {pmG828TpMaintTable 1}
|
|
|
|
PmG828TpMaintRecord ::=
|
|
SEQUENCE {
|
|
pmG828TpMaintCounterClear INTEGER,
|
|
pmG828TpMaintAlarmClear INTEGER
|
|
}
|
|
|
|
pmG828TpMaintCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notActive (0),
|
|
clear (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the Perfomance Monitoring counters."
|
|
::= {pmG828TpMaintRecord 1}
|
|
|
|
pmG828TpMaintAlarmClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notActive (0),
|
|
clear (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to clear the Perfomance Monitoring threshold cross alarms."
|
|
::= {pmG828TpMaintRecord 2}
|
|
--
|
|
------- End of pmG828TpMaintTable
|
|
|
|
--
|
|
------- The following objects are common to all instances.
|
|
--
|
|
pmG828NSesSetUAS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of SES (according G.828) to set UAS."
|
|
DEFVAL {10}
|
|
::= {pmG828 5}
|
|
|
|
pmG828NSesResetUAS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds whitout errors (according G.828) to reset UAS."
|
|
DEFVAL {10}
|
|
::= {pmG828 6}
|
|
|
|
pmG828TpClass15MEsAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the severity associated to the pmG828TpClass15MEsAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 7}
|
|
|
|
pmG828TpClass15MSesAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClass15MSesAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 8}
|
|
|
|
pmG828TpClass24HEsAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClass15MEsAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 9}
|
|
|
|
pmG828TpClass24HSesAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClass15MSesAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 10}
|
|
|
|
pmG828TpClassUASAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClassUASAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 11}
|
|
|
|
pmG828TpClass15MSepAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClass15MSepAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 12}
|
|
|
|
pmG828TpClass24HSepAlarmSeverityCode OBJECT-TYPE
|
|
SYNTAX AlarmSeverityCode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Define the severity associated to the pmG828TpClass24HSepAlarm and
|
|
enables/disables the trap generation on status change event."
|
|
DEFVAL {majorTrapEnable}
|
|
::= {pmG828 13}
|
|
|
|
------ End group -----------------------------------------------------------------
|
|
|
|
END
|
|
|
|
|
|
|
|
|