3354 lines
69 KiB
Plaintext
3354 lines
69 KiB
Plaintext
|
|
-- Radio Bridge MIB
|
|
|
|
|
|
RADIO-BRIDGE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises
|
|
FROM RFC1155-SMI
|
|
TruthValue, DisplayString, RowStatus
|
|
FROM SNMPv2-TC
|
|
OBJECT-TYPE, Integer32, Gauge32, Counter64, IpAddress, TimeTicks, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
ifIndex
|
|
FROM IF-MIB
|
|
InterfaceIndex
|
|
FROM IF-MIB
|
|
dot1agCfmMepEntry
|
|
FROM IEEE8021-CFM-MIB
|
|
ieee8021QBridgeTpFdbEntry
|
|
FROM IEEE8021-Q-BRIDGE-MIB
|
|
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
|
|
-- Siklu Root
|
|
radioBridgeRoot OBJECT IDENTIFIER ::= { enterprises 31926 }
|
|
|
|
|
|
radioBridgeSystem OBJECT IDENTIFIER ::= { radioBridgeRoot 1 }
|
|
radioBridgeRf OBJECT IDENTIFIER ::= { radioBridgeRoot 2 }
|
|
radioBridgeTraps OBJECT IDENTIFIER ::= { radioBridgeRoot 3 }
|
|
radioBridgeRefClock OBJECT IDENTIFIER ::= { radioBridgeRoot 4 }
|
|
radioBridgeEthernet OBJECT IDENTIFIER ::= { radioBridgeRoot 5 }
|
|
radioBridgeQosClassifier OBJECT IDENTIFIER ::= { radioBridgeRoot 6 }
|
|
radioBridgeQosIngressQueue OBJECT IDENTIFIER ::= { radioBridgeRoot 7 }
|
|
radioBridgeQosEgressQueue OBJECT IDENTIFIER ::= { radioBridgeRoot 8 }
|
|
radioBridgeIp OBJECT IDENTIFIER ::= { radioBridgeRoot 9 }
|
|
radioBridgeCfm OBJECT IDENTIFIER ::= { radioBridgeRoot 10 }
|
|
radioBridgeAlarms OBJECT IDENTIFIER ::= { radioBridgeRoot 11 }
|
|
radioBridgeScheduler OBJECT IDENTIFIER ::= { radioBridgeRoot 12 }
|
|
radioBridgeEncryption OBJECT IDENTIFIER ::= { radioBridgeRoot 13 }
|
|
radioBridgeMeter OBJECT IDENTIFIER ::= { radioBridgeRoot 14 }
|
|
radioBridgeEventConfig OBJECT IDENTIFIER ::= { radioBridgeRoot 15 }
|
|
radioBridgeSnmp OBJECT IDENTIFIER ::= { radioBridgeRoot 17 }
|
|
-- rbSysFileOperationTable ::= { radioBridgeRoot 18 } see below
|
|
radioBridgeLldp OBJECT IDENTIFIER ::= { radioBridgeRoot 19 }
|
|
radioBridgeWred OBJECT IDENTIFIER ::= { radioBridgeRoot 20 }
|
|
radioBridgeAuthentication OBJECT IDENTIFIER ::= { radioBridgeRoot 21 }
|
|
radioBridgeQuota OBJECT IDENTIFIER ::= { radioBridgeRoot 22 }
|
|
radioBridgePcpProfile OBJECT IDENTIFIER ::= { radioBridgeRoot 23 }
|
|
radioBridgeSyslog OBJECT IDENTIFIER ::= { radioBridgeRoot 24 }
|
|
radioBridgeNtp OBJECT IDENTIFIER ::= { radioBridgeRoot 25 }
|
|
radioBridgeLicense OBJECT IDENTIFIER ::= { radioBridgeRoot 26 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge system extension
|
|
-- ===========================================================
|
|
|
|
rbSysVoltage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 1 }
|
|
|
|
rbSysTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 2 }
|
|
|
|
rbSysSaveConfiguration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 3 }
|
|
|
|
rbSysReset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Read the variable value and then write this value for reset"
|
|
::= { radioBridgeSystem 4 }
|
|
|
|
rbSwBank1Version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 5 }
|
|
|
|
rbSwBank2Version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 6 }
|
|
|
|
rbSwBank1Running OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noRunning(1),
|
|
running(2),
|
|
running-wait-accept(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 7 }
|
|
|
|
rbSwBank2Running OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noRunning(1),
|
|
running(2),
|
|
running-wait-accept(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 8 }
|
|
|
|
rbSwBank1ScheduledToRunNextReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 9 }
|
|
|
|
rbSwBank2ScheduledToRunNextReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 10 }
|
|
|
|
rbSystemUpAbsoluteTime OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"since the Epoch (00:00:00 UTC, January 1, 1970), measured in seconds."
|
|
::= { radioBridgeSystem 11 }
|
|
|
|
rbSystemAuthenticationMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
local(1),
|
|
radius(2),
|
|
tacacs(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 12 }
|
|
|
|
rbSystemAuthenticationSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 13 }
|
|
|
|
|
|
rbSystemCapabilities OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
nmsFtp(0)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 14 }
|
|
|
|
rbDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 15 }
|
|
|
|
rbTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSystem 16 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge RF table
|
|
-- ===========================================================
|
|
|
|
rbRfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbRfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeRf 1 }
|
|
|
|
rbRfEntry OBJECT-TYPE
|
|
SYNTAX RbRfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rfIndex }
|
|
::= { rbRfTable 1 }
|
|
|
|
RbRfEntry ::= SEQUENCE {
|
|
rfIndex Integer32,
|
|
rfNumOfChannels Integer32,
|
|
rfChannelWidth INTEGER,
|
|
rfOperationalFrequency Integer32,
|
|
rfRole INTEGER,
|
|
rfModeSelector INTEGER,
|
|
rfModulationType INTEGER,
|
|
rfNumOfSubchannels Integer32,
|
|
rfNumOfRepetitions Integer32,
|
|
rfFecRate INTEGER,
|
|
rfOperationalState TruthValue,
|
|
rfAverageCinr Integer32,
|
|
rfAverageRssi Integer32,
|
|
rfTxSynthLock INTEGER,
|
|
rfRxSynthLock INTEGER,
|
|
rfRxLinkId Integer32,
|
|
rfTxLinkId Integer32,
|
|
rfTxState INTEGER,
|
|
rfRxState INTEGER,
|
|
rfTemperature Integer32,
|
|
rfAsymmetry INTEGER,
|
|
|
|
rfLowestModulationType INTEGER,
|
|
rfLowestNumOfSubchannels Integer32,
|
|
rfLowestNumOfRepetitions Integer32,
|
|
rfLowestFecRate INTEGER,
|
|
|
|
rfTxMute TruthValue,
|
|
rfRoleStatus INTEGER,
|
|
|
|
rfLoopModeSelector INTEGER,
|
|
rfLoopDirection INTEGER,
|
|
rfLoopModulationType INTEGER,
|
|
rfLoopNumOfSubchannels Integer32,
|
|
rfLoopNumOfRepetitions Integer32,
|
|
rfLoopFecRate INTEGER,
|
|
rfLoopTimeout Integer32,
|
|
|
|
rfTxPower Integer32,
|
|
rfTxMuteTimeout Integer32,
|
|
rfAlignmentStatus INTEGER
|
|
}
|
|
|
|
|
|
rfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 1 }
|
|
|
|
rfNumOfChannels OBJECT-TYPE
|
|
SYNTAX Integer32(1 | 2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 2 }
|
|
|
|
rfChannelWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfWidth250(1),
|
|
rfWidth500(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 3 }
|
|
|
|
rfOperationalFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 4 }
|
|
|
|
rfRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfMaster(1),
|
|
rfSlave(2),
|
|
rfAuto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 5 }
|
|
|
|
rfModeSelector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfModeAdaptive(1),
|
|
rfModeStatic(2),
|
|
rfModeAlign(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 6 }
|
|
|
|
rfModulationType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfModulationQPSK(1),
|
|
rfModulationQAM-16(2),
|
|
rfModulationQAM-64(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 7 }
|
|
|
|
rfNumOfSubchannels OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 8 }
|
|
|
|
rfNumOfRepetitions OBJECT-TYPE
|
|
SYNTAX Integer32 (1 | 2 | 4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 9 }
|
|
|
|
rfFecRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfFEC-05(1),
|
|
rfFEC-067(2),
|
|
rfFEC-08(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 10 }
|
|
|
|
rfOperationalState OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 17 }
|
|
|
|
rfAverageCinr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 18 }
|
|
|
|
rfAverageRssi OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 19 }
|
|
|
|
rfTxSynthLock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
txSynthUnlock(0),
|
|
txSynthLock(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 20 }
|
|
|
|
rfRxSynthLock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rxSynthUnlock(0),
|
|
rxSynthLock(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 21 }
|
|
|
|
rfRxLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..127)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 22 }
|
|
|
|
rfTxLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..127)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 23 }
|
|
|
|
rfTxState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rf-sync(1),
|
|
rf-searchCountdown(2),
|
|
rf-foundCountdown(3),
|
|
rf-normal(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 24 }
|
|
|
|
rfRxState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rf-sync(1),
|
|
rf-searchCountdown(2),
|
|
rf-foundCountdown(3),
|
|
rf-normal(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 25 }
|
|
|
|
rfTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 26 }
|
|
|
|
rfAsymmetry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rf-asymmetry-25tx-75rx(1),
|
|
rf-asymmetry-50tx-50rx(2),
|
|
rf-asymmetry-75tx-25rx(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 27 }
|
|
|
|
|
|
rfLowestModulationType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfModulationQPSK(1),
|
|
rfModulationQAM-16(2),
|
|
rfModulationQAM-64(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 30 }
|
|
|
|
rfLowestNumOfSubchannels OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 31}
|
|
|
|
rfLowestNumOfRepetitions OBJECT-TYPE
|
|
SYNTAX Integer32 (1 | 2 | 4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 32 }
|
|
|
|
rfLowestFecRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfFEC-05(1),
|
|
rfFEC-067(2),
|
|
rfFEC-08(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 33 }
|
|
|
|
rfTxMute OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 34 }
|
|
|
|
rfRoleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfMaster(1),
|
|
rfSlave(2),
|
|
rfAuto(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 35 }
|
|
|
|
rfLoopModeSelector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfLoopDisabled(1),
|
|
rfLoopInternalMacSwap(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 36 }
|
|
|
|
rfLoopModulationType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfModulationQPSK(1),
|
|
rfModulationQAM-16(2),
|
|
rfModulationQAM-64(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 37 }
|
|
|
|
rfLoopNumOfSubchannels OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 38 }
|
|
|
|
rfLoopNumOfRepetitions OBJECT-TYPE
|
|
SYNTAX Integer32 (1 | 2 | 4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 39 }
|
|
|
|
rfLoopFecRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfFEC-05(1),
|
|
rfFEC-067(2),
|
|
rfFEC-08(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 40 }
|
|
|
|
rfLoopTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 41 }
|
|
|
|
rfTxPower OBJECT-TYPE
|
|
SYNTAX Integer32 (-35 .. 8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 42 }
|
|
|
|
rfTxMuteTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0 .. 86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 43 }
|
|
|
|
rfAlignmentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfAlignmentInactive(0),
|
|
rfAlignmentActive(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 44 }
|
|
|
|
rfLoopDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfLoop-tx(1),
|
|
rfLoop-rx(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfEntry 45 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge RF statistics table
|
|
-- ===========================================================
|
|
|
|
|
|
rbRfStatisticsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbRfStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeRf 2 }
|
|
|
|
rbRfStatisticsEntry OBJECT-TYPE
|
|
SYNTAX RbRfStatisticsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rfIndex }
|
|
::= { rbRfStatisticsTable 1 }
|
|
|
|
RbRfStatisticsEntry ::= SEQUENCE {
|
|
rfInOctets Counter64,
|
|
rfInIdleOctets Counter64,
|
|
rfInGoodOctets Counter64,
|
|
rfInErroredOctets Counter64,
|
|
rfOutOctets Counter64,
|
|
rfOutIdleOctets Counter64,
|
|
rfInPkts Counter64,
|
|
rfInGoodPkts Counter64,
|
|
rfInErroredPkts Counter64,
|
|
rfInLostPkts Counter64,
|
|
rfOutPkts Counter64,
|
|
rfMinCinr Counter64,
|
|
rfMaxCinr Counter64,
|
|
rfMinRssi Counter64,
|
|
rfMaxRssi Counter64,
|
|
rfMinModulation Counter64,
|
|
rfMaxModulation Counter64,
|
|
|
|
rfValid TruthValue,
|
|
|
|
rfArqInLoss Counter64,
|
|
rfArqOutLoss Counter64
|
|
}
|
|
|
|
|
|
rfInOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 1 }
|
|
|
|
rfInIdleOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 2 }
|
|
|
|
rfInGoodOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 3 }
|
|
|
|
rfInErroredOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 4 }
|
|
|
|
rfOutOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 5 }
|
|
|
|
rfOutIdleOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 6 }
|
|
|
|
rfInPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 7 }
|
|
|
|
rfInGoodPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 8 }
|
|
|
|
rfInErroredPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 9 }
|
|
|
|
rfInLostPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 10 }
|
|
|
|
rfOutPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 11 }
|
|
|
|
rfMinCinr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 15 }
|
|
|
|
rfMaxCinr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 16 }
|
|
|
|
rfMinRssi OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 17 }
|
|
|
|
rfMaxRssi OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 18 }
|
|
|
|
rfMinModulation OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
byte # 3: see rfModulationType;
|
|
byte # 2: see rfNumOfSubchannels;
|
|
byte # 1: see rfNumOfRepetitions;
|
|
byte # 0: see rfFecRate;
|
|
"
|
|
::= { rbRfStatisticsEntry 19 }
|
|
|
|
rfMaxModulation OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
byte # 3: see rfModulationType;
|
|
byte # 2: see rfNumOfSubchannels;
|
|
byte # 1: see rfNumOfRepetitions;
|
|
byte # 0: see rfFecRate;
|
|
"
|
|
::= { rbRfStatisticsEntry 20 }
|
|
|
|
rfValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 21 }
|
|
|
|
rfArqInLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 22 }
|
|
|
|
|
|
rfArqOutLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsEntry 23 }
|
|
|
|
-- ===========================================================
|
|
|
|
rbRfStatisticsDaysTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbRfStatisticsDaysEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeRf 3 }
|
|
|
|
rbRfStatisticsDaysEntry OBJECT-TYPE
|
|
SYNTAX RbRfStatisticsDaysEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rfIndex, rfDayIndex }
|
|
::= { rbRfStatisticsDaysTable 1 }
|
|
|
|
RbRfStatisticsDaysEntry ::= SEQUENCE {
|
|
rfDayIndex Integer32,
|
|
rfDaysStart TimeTicks,
|
|
|
|
rfDaysInOctets Counter64,
|
|
rfDaysInIdleOctets Counter64,
|
|
rfDaysInGoodOctets Counter64,
|
|
rfDaysInErroredOctets Counter64,
|
|
rfDaysOutOctets Counter64,
|
|
rfDaysOutIdleOctets Counter64,
|
|
rfDaysInPkts Counter64,
|
|
rfDaysInGoodPkts Counter64,
|
|
rfDaysInErroredPkts Counter64,
|
|
rfDaysInLostPkts Counter64,
|
|
rfDaysOutPkts Counter64,
|
|
rfDaysMinCinr Counter64,
|
|
rfDaysMaxCinr Counter64,
|
|
rfDaysMinRssi Counter64,
|
|
rfDaysMaxRssi Counter64,
|
|
rfDaysMinModulation Counter64,
|
|
rfDaysMaxModulation Counter64,
|
|
|
|
rfDaysValid TruthValue,
|
|
|
|
rfDaysArqInLoss Counter64,
|
|
rfDaysArqOutLoss Counter64
|
|
}
|
|
|
|
rfDayIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 50 }
|
|
|
|
rfDaysStart OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 51 }
|
|
|
|
|
|
rfDaysInOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 1 }
|
|
|
|
rfDaysInIdleOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 2 }
|
|
|
|
rfDaysInGoodOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 3 }
|
|
|
|
rfDaysInErroredOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 4 }
|
|
|
|
rfDaysOutOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 5 }
|
|
|
|
rfDaysOutIdleOctets OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 6 }
|
|
|
|
rfDaysInPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 7 }
|
|
|
|
rfDaysInGoodPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 8 }
|
|
|
|
rfDaysInErroredPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 9 }
|
|
|
|
rfDaysInLostPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 10 }
|
|
|
|
rfDaysOutPkts OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 11 }
|
|
|
|
rfDaysMinCinr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 15 }
|
|
|
|
rfDaysMaxCinr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 16 }
|
|
|
|
rfDaysMinRssi OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 17 }
|
|
|
|
rfDaysMaxRssi OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 18 }
|
|
|
|
rfDaysMinModulation OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
byte # 3: see rfModulationType;
|
|
byte # 2: see rfNumOfSubchannels;
|
|
byte # 1: see rfNumOfRepetitions;
|
|
byte # 0: see rfFecRate;
|
|
"
|
|
::= { rbRfStatisticsDaysEntry 19 }
|
|
|
|
rfDaysMaxModulation OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
byte # 3: see rfModulationType;
|
|
byte # 2: see rfNumOfSubchannels;
|
|
byte # 1: see rfNumOfRepetitions;
|
|
byte # 0: see rfFecRate;
|
|
"
|
|
::= { rbRfStatisticsDaysEntry 20 }
|
|
|
|
rfDaysValid OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 21 }
|
|
|
|
rfDaysArqInLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 22 }
|
|
|
|
|
|
rfDaysArqOutLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRfStatisticsDaysEntry 23 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge reference clock table
|
|
-- ===========================================================
|
|
|
|
rbRefClockTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbRefClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeRefClock 1 }
|
|
|
|
|
|
rbRefClockEntry OBJECT-TYPE
|
|
SYNTAX RbRefClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ifIndex }
|
|
::= { rbRefClockTable 1 }
|
|
|
|
RbRefClockEntry ::= SEQUENCE {
|
|
refClockPrio Integer32,
|
|
refClockStatus INTEGER,
|
|
refClockQualityLevelActual Integer32,
|
|
refClockQualityLevelConfig Integer32,
|
|
refClockQualityLevelMode TruthValue,
|
|
refClockSsmCvid Integer32,
|
|
refClockRowStatus RowStatus
|
|
}
|
|
|
|
refClockPrio OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 1 }
|
|
|
|
refClockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
down(0),
|
|
active(1),
|
|
backup-1(2),
|
|
backup-2(3),
|
|
backup-3(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 2 }
|
|
|
|
refClockQualityLevelActual OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 3 }
|
|
|
|
refClockQualityLevelConfig OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 4 }
|
|
|
|
refClockQualityLevelMode OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 5 }
|
|
|
|
refClockSsmCvid OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 6 }
|
|
|
|
refClockRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbRefClockEntry 7 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge ethernet table
|
|
-- ===========================================================
|
|
|
|
rbEthernetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbEthernetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeEthernet 1 }
|
|
|
|
|
|
rbEthernetEntry OBJECT-TYPE
|
|
SYNTAX RbEthernetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ifIndex }
|
|
::= { rbEthernetTable 1 }
|
|
|
|
RbEthernetEntry ::= SEQUENCE {
|
|
ethernetAlarmPropagation INTEGER,
|
|
ethernetLoopMode INTEGER,
|
|
ethernetLoopTimeout INTEGER,
|
|
ethernetNetworkType INTEGER,
|
|
ethernetPcpWriteProfileId Integer32,
|
|
ethernetClassifierMode INTEGER
|
|
}
|
|
|
|
ethernetAlarmPropagation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
backward(1),
|
|
forward(2),
|
|
both-direct(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEthernetEntry 2 }
|
|
|
|
ethernetLoopMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(0),
|
|
external(1),
|
|
external-mac-swap(2),
|
|
internal(3),
|
|
internal-mac-swap(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEthernetEntry 3 }
|
|
|
|
ethernetLoopTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEthernetEntry 4 }
|
|
|
|
ethernetNetworkType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
provider-nni(1),
|
|
customer-uni(2),
|
|
customer-nni(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEthernetEntry 5 }
|
|
|
|
|
|
ethernetPcpWriteProfileId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"id of pcp write profile or none (0)"
|
|
::= { rbEthernetEntry 6 }
|
|
|
|
ethernetClassifierMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
classifier-mode-dscp(1),
|
|
classifier-mode-pcp-dscp(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEthernetEntry 7 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge classifier cos table
|
|
-- ===========================================================
|
|
|
|
rbClassifierCosTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbClassifierCosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQosClassifier 1 }
|
|
|
|
|
|
rbClassifierCosEntry OBJECT-TYPE
|
|
SYNTAX RbClassifierCosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { classifierCosId }
|
|
::= { rbClassifierCosTable 1 }
|
|
|
|
RbClassifierCosEntry ::= SEQUENCE {
|
|
classifierCosId Integer32,
|
|
classifierCosPortList OCTET STRING,
|
|
classifierCosPrecedence Integer32,
|
|
classifierCosVidList OCTET STRING,
|
|
classifierCosPcpList OCTET STRING,
|
|
classifierCosCos Integer32,
|
|
classifierCosIpCosType INTEGER,
|
|
classifierCosIpCosList OCTET STRING,
|
|
classifierCosPacketType INTEGER,
|
|
classifierCosRowStatus RowStatus
|
|
}
|
|
|
|
classifierCosId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..248)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 1 }
|
|
|
|
classifierCosPortList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 2 }
|
|
|
|
classifierCosPrecedence OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 3 }
|
|
|
|
classifierCosVidList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 4 }
|
|
|
|
classifierCosPcpList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 5 }
|
|
|
|
classifierCosCos OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 6 }
|
|
|
|
|
|
classifierCosIpCosType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ip-cos-dscp(1),
|
|
ip-cos-mpls(2),
|
|
ip-cos-dont-care(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 7 }
|
|
|
|
|
|
classifierCosIpCosList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 8 }
|
|
|
|
|
|
classifierCosRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 9 }
|
|
|
|
|
|
classifierCosPacketType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unicast(1),
|
|
non-unicast(2),
|
|
all(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierCosEntry 10 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge classifier evc table
|
|
-- ===========================================================
|
|
|
|
rbClassifierEvcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbClassifierEvcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQosClassifier 2 }
|
|
|
|
|
|
rbClassifierEvcEntry OBJECT-TYPE
|
|
SYNTAX RbClassifierEvcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { classifierEvcId }
|
|
::= { rbClassifierEvcTable 1 }
|
|
|
|
RbClassifierEvcEntry ::= SEQUENCE {
|
|
classifierEvcId Integer32,
|
|
classifierEvcPortList OCTET STRING,
|
|
classifierEvcPrecedence Integer32,
|
|
classifierEvcVidList OCTET STRING,
|
|
classifierEvcPcpList OCTET STRING,
|
|
classifierEvcEvc Integer32,
|
|
classifierEvcIpCosType INTEGER,
|
|
classifierEvcIpCosList OCTET STRING,
|
|
classifierEvcPacketType INTEGER,
|
|
classifierEvcRowStatus RowStatus
|
|
}
|
|
|
|
|
|
classifierEvcId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..248)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 1 }
|
|
|
|
classifierEvcPortList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 2 }
|
|
|
|
classifierEvcPrecedence OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 3 }
|
|
|
|
classifierEvcVidList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 4 }
|
|
|
|
classifierEvcPcpList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 5 }
|
|
|
|
classifierEvcEvc OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4095)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 6 }
|
|
|
|
classifierEvcIpCosType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ip-cos-dscp(1),
|
|
ip-cos-mpls(2),
|
|
ip-cos-dont-care(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 7 }
|
|
|
|
classifierEvcIpCosList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 8 }
|
|
|
|
|
|
classifierEvcRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 9 }
|
|
|
|
classifierEvcPacketType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unicast(1),
|
|
non-unicast(2),
|
|
all(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbClassifierEvcEntry 10 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge qos ingress queue table
|
|
-- ===========================================================
|
|
|
|
rbQosIngressQueueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbQosIngressQueueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQosIngressQueue 1 }
|
|
|
|
rbQosIngressQueueEntry OBJECT-TYPE
|
|
SYNTAX RbQosIngressQueueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { qosIngressQueueEvcId, qosIngressQueueCosId }
|
|
::= { rbQosIngressQueueTable 1 }
|
|
|
|
RbQosIngressQueueEntry ::= SEQUENCE {
|
|
qosIngressQueueEvcId Integer32,
|
|
qosIngressQueueCosId Integer32,
|
|
|
|
qosIngressQueueMeterId Integer32,
|
|
qosIngressQueueMarking TruthValue,
|
|
qosIngressQueueRowStatus RowStatus
|
|
}
|
|
|
|
qosIngressQueueEvcId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosIngressQueueEntry 1 }
|
|
|
|
qosIngressQueueCosId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosIngressQueueEntry 2 }
|
|
|
|
qosIngressQueueMeterId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosIngressQueueEntry 3 }
|
|
|
|
qosIngressQueueMarking OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosIngressQueueEntry 4 }
|
|
|
|
qosIngressQueueRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry."
|
|
::= { rbQosIngressQueueEntry 6 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge qos egress queue table
|
|
-- ===========================================================
|
|
|
|
rbQosEgressQueueTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbQosEgressQueueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQosEgressQueue 1 }
|
|
|
|
rbQosEgressQueueEntry OBJECT-TYPE
|
|
SYNTAX RbQosEgressQueueEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { qosEgressQueuePortNum, qosEgressQueueCosId }
|
|
::= { rbQosEgressQueueTable 1 }
|
|
|
|
RbQosEgressQueueEntry ::= SEQUENCE {
|
|
qosEgressQueuePortNum Integer32,
|
|
qosEgressQueueCosId Integer32,
|
|
qosEgressQueueWfqWeight Integer32,
|
|
qosEgressQueueCir Integer32,
|
|
qosEgressQueueMode INTEGER,
|
|
qosEgressQueueColorDrop INTEGER,
|
|
qosEgressDropMode Integer32
|
|
}
|
|
|
|
qosEgressQueuePortNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 1 }
|
|
|
|
qosEgressQueueCosId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 2 }
|
|
|
|
qosEgressQueueWfqWeight OBJECT-TYPE
|
|
SYNTAX Integer32 (0..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 4 }
|
|
|
|
qosEgressQueueCir OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 5 }
|
|
|
|
qosEgressQueueMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
strictPriority(1),
|
|
wfg(2),
|
|
priority-shaper(3),
|
|
wfq-shaper(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 6 }
|
|
|
|
qosEgressQueueColorDrop OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
color-aware(1),
|
|
color-drop(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbQosEgressQueueEntry 7 }
|
|
|
|
qosEgressDropMode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"if negative then wred id, else queue length in microseconds"
|
|
::= { rbQosEgressQueueEntry 8 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge IP
|
|
-- ===========================================================
|
|
|
|
rbIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeIp 1 }
|
|
|
|
rbIpEntry OBJECT-TYPE
|
|
SYNTAX RbIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbIpIndex }
|
|
::= { rbIpTable 1 }
|
|
|
|
RbIpEntry ::= SEQUENCE {
|
|
rbIpIndex Integer32,
|
|
rbIpType INTEGER,
|
|
rbIpAddress IpAddress,
|
|
rbIpPrefixLen Integer32,
|
|
rbIpVlanId Integer32,
|
|
rbIpGateway IpAddress,
|
|
rbIpRowStatus RowStatus
|
|
}
|
|
|
|
rbIpIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 1 }
|
|
|
|
rbIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 2 }
|
|
|
|
rbIpPrefixLen OBJECT-TYPE
|
|
SYNTAX Integer32 (0..32)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 3 }
|
|
|
|
|
|
rbIpVlanId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 4 }
|
|
|
|
rbIpRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of this entry."
|
|
::= { rbIpEntry 5 }
|
|
|
|
rbIpType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ip-static(1),
|
|
ip-dhcp(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 6 }
|
|
|
|
rbIpGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbIpEntry 7 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge CFM
|
|
-- ===========================================================
|
|
|
|
rbPeerMep OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbPeerMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeCfm 1 }
|
|
|
|
rbPeerMepEntry OBJECT-TYPE
|
|
SYNTAX RbPeerMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbMdIndex, rbMaIndex, rbMepId, rbPeerMepId }
|
|
::= { rbPeerMep 1 }
|
|
|
|
|
|
RbPeerMepEntry ::= SEQUENCE {
|
|
rbMdIndex Integer32,
|
|
rbMaIndex Integer32,
|
|
rbMepId Integer32,
|
|
rbPeerMepId Integer32,
|
|
|
|
rbPeerMepFarEndLoss Counter64,
|
|
rbPeerMepNearEndLoss Counter64,
|
|
rbPeerMepTotalTxFarEnd Counter64,
|
|
rbPeerMepTotalTxNearEnd Counter64,
|
|
rbPeerMepFrameDelay Counter64,
|
|
rbPeerMepFrameDelayVariation Counter64
|
|
}
|
|
|
|
rbMdIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 1 }
|
|
|
|
rbMaIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 2 }
|
|
|
|
rbMepId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 3 }
|
|
|
|
rbPeerMepId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 4 }
|
|
|
|
rbPeerMepFarEndLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 5 }
|
|
|
|
rbPeerMepNearEndLoss OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 6 }
|
|
|
|
rbPeerMepTotalTxFarEnd OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 7 }
|
|
|
|
rbPeerMepTotalTxNearEnd OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 8 }
|
|
|
|
rbPeerMepFrameDelay OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 9 }
|
|
|
|
rbPeerMepFrameDelayVariation OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPeerMepEntry 10 }
|
|
|
|
-- ===========================================================
|
|
|
|
rbMep OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeCfm 2 }
|
|
|
|
rbMepEntry OBJECT-TYPE
|
|
SYNTAX RbMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { rbMep 1 }
|
|
|
|
|
|
RbMepEntry ::= SEQUENCE {
|
|
rbMepAisEnable TruthValue,
|
|
rbMepAisPeriod INTEGER,
|
|
rbMepAisSuppress TruthValue,
|
|
rbMepAisLevel Integer32,
|
|
rbMepAisDefects TruthValue
|
|
}
|
|
|
|
rbMepAisEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMepEntry 1 }
|
|
|
|
rbMepAisPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
aisPeriod-1-sec(4),
|
|
aisPeriod-1-min(6)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMepEntry 2 }
|
|
|
|
rbMepAisSuppress OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMepEntry 3 }
|
|
|
|
rbMepAisLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMepEntry 4 }
|
|
|
|
rbMepAisDefects OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMepEntry 5 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge alarms
|
|
-- ===========================================================
|
|
|
|
AlarmSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
SYNTAX INTEGER
|
|
{
|
|
critical(1),
|
|
major(2),
|
|
minor(3),
|
|
warning(4),
|
|
no-alarm(5) -- used for scalar rbCurrentAlarmMostSevere only
|
|
}
|
|
|
|
AlarmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
SYNTAX INTEGER
|
|
{
|
|
link-down(1),
|
|
temperature-out-of-range(2),
|
|
synthesizer-unlock(3),
|
|
pow-low(4),
|
|
cfm-mep-defect(5),
|
|
loopback-active(6),
|
|
tx-mute(7),
|
|
ql-eec1-or-worse(8),
|
|
poe-incompatible(9),
|
|
rssi-out-of-range(10),
|
|
cinr-out-of-range(11),
|
|
lowest-modulation(12)
|
|
}
|
|
|
|
rbAlarmsCommon OBJECT IDENTIFIER ::= { radioBridgeAlarms 1 }
|
|
|
|
|
|
rbCurrentAlarmChangeCounter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter is initialized by random number on power-up and incremented on each change
|
|
in the current alarms table: alarm addition or deletion."
|
|
::= { rbAlarmsCommon 1 }
|
|
|
|
rbCurrentAlarmMostSevere OBJECT-TYPE
|
|
SYNTAX AlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the most severe alarm in the system"
|
|
::= { rbAlarmsCommon 2 }
|
|
|
|
rbCurrentAlarmLastIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter is initialized by random number on power-up and incremented when alarm is added to the alarms table.
|
|
It is used as alarm index in current alarms table."
|
|
::= { rbAlarmsCommon 3 }
|
|
|
|
rbCurrentAlarmLastTrapType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alarm-up(1),
|
|
alarm-down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of last alarm trap."
|
|
::= { rbAlarmsCommon 4 }
|
|
|
|
rbCurrentAlarmSourceAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm source IP Address."
|
|
::= { rbAlarmsCommon 10 }
|
|
|
|
rbCurrentAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbCurrentAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current alarms table."
|
|
::= { radioBridgeAlarms 2 }
|
|
|
|
rbCurrentAlarmEntry OBJECT-TYPE
|
|
SYNTAX RbCurrentAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbCurrentAlarmIndex }
|
|
::= { rbCurrentAlarmTable 1 }
|
|
|
|
RbCurrentAlarmEntry ::=
|
|
SEQUENCE
|
|
{
|
|
rbCurrentAlarmIndex INTEGER,
|
|
rbCurrentAlarmType AlarmType,
|
|
rbCurrentAlarmTypeName DisplayString,
|
|
rbCurrentAlarmSource DisplayString,
|
|
rbCurrentAlarmSeverity AlarmSeverity,
|
|
rbCurrentAlarmRaisedTime TimeTicks,
|
|
rbCurrentAlarmDesc DisplayString,
|
|
rbCurrentAlarmCause DisplayString,
|
|
rbCurrentAlarmAction DisplayString,
|
|
rbCurrentAlarmIfIndex INTEGER
|
|
}
|
|
|
|
rbCurrentAlarmIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of the rbCurrentAlarmLastIndex when alarm is inserted to the table."
|
|
::= { rbCurrentAlarmEntry 1 }
|
|
|
|
rbCurrentAlarmType OBJECT-TYPE
|
|
SYNTAX AlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"see AlarmType definition"
|
|
::= { rbCurrentAlarmEntry 2 }
|
|
|
|
rbCurrentAlarmTypeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"string presentation of the rbCurrentAlarmType"
|
|
::= { rbCurrentAlarmEntry 3 }
|
|
|
|
rbCurrentAlarmSource OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"name of the managed object originating the alarm: eth host, system, vlan s1 5 etc."
|
|
::= { rbCurrentAlarmEntry 4 }
|
|
|
|
rbCurrentAlarmSeverity OBJECT-TYPE
|
|
SYNTAX AlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"see AlarmSeverity definition"
|
|
::= { rbCurrentAlarmEntry 5 }
|
|
|
|
rbCurrentAlarmRaisedTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbCurrentAlarmEntry 6 }
|
|
|
|
rbCurrentAlarmDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"alarm description"
|
|
::= { rbCurrentAlarmEntry 7 }
|
|
|
|
rbCurrentAlarmCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"alarm probably cause"
|
|
::= { rbCurrentAlarmEntry 8 }
|
|
|
|
rbCurrentAlarmAction OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"alarm corrective actions"
|
|
::= { rbCurrentAlarmEntry 9 }
|
|
|
|
rbCurrentAlarmIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"port ifIndex if port is the alarm source, -1 otherwise"
|
|
::= { rbCurrentAlarmEntry 10 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge Traps
|
|
-- ===========================================================
|
|
|
|
trapModulationChange NOTIFICATION-TYPE
|
|
OBJECTS { rfModulationType, rfNumOfSubchannels, rfNumOfRepetitions, rfFecRate }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 1 }
|
|
|
|
trapTemperatureOutOfRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 2 }
|
|
|
|
trapTemperatureInRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 3 }
|
|
|
|
trapSfpIn NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 4 }
|
|
|
|
trapSfpOut NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 5 }
|
|
|
|
trapRefClockChanged NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex, refClockQualityLevelActual }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 6 }
|
|
|
|
trapCurrentAlarm NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
rbCurrentAlarmChangeCounter,
|
|
rbCurrentAlarmMostSevere,
|
|
rbCurrentAlarmType,
|
|
rbCurrentAlarmTypeName,
|
|
rbCurrentAlarmSourceAddr,
|
|
rbCurrentAlarmSource,
|
|
rbCurrentAlarmSeverity,
|
|
rbCurrentAlarmRaisedTime,
|
|
rbCurrentAlarmIfIndex,
|
|
rbCurrentAlarmLastTrapType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 11 }
|
|
|
|
trapLoopEnabled NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 12 }
|
|
|
|
trapLoopDisabled NOTIFICATION-TYPE
|
|
OBJECTS { ifIndex }
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 13 }
|
|
|
|
trapTxMuteEnabled NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 14 }
|
|
|
|
trapTxMuteDisabled NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 15 }
|
|
|
|
|
|
trapCinrOutOfRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 19 }
|
|
|
|
trapCinrInRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 20 }
|
|
|
|
trapRssiOutOfRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 21 }
|
|
|
|
trapRssiInRange NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 22 }
|
|
|
|
trapLowestModulation NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 23 }
|
|
|
|
trapNoLowestModulation NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeTraps 24 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge scheduler
|
|
-- ===========================================================
|
|
|
|
rbSchedulerMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
strictPriority(1),
|
|
wfg(2),
|
|
priority-shaper(3),
|
|
wfq-shaper(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeScheduler 1 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge meter
|
|
-- ===========================================================
|
|
|
|
rbMeterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbMeterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeMeter 1 }
|
|
|
|
rbMeterEntry OBJECT-TYPE
|
|
SYNTAX RbMeterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbMeterId }
|
|
::= { rbMeterTable 1 }
|
|
|
|
RbMeterEntry ::= SEQUENCE {
|
|
rbMeterId Integer32,
|
|
rbMeterCir Integer32,
|
|
rbMeterCbs Integer32,
|
|
rbMeterEir Integer32,
|
|
rbMeterEbs Integer32,
|
|
rbMeterColorMode INTEGER,
|
|
rbMeterRowStatus RowStatus
|
|
}
|
|
|
|
rbMeterId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..248)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 1 }
|
|
|
|
rbMeterCir OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 2 }
|
|
|
|
rbMeterCbs OBJECT-TYPE
|
|
SYNTAX Integer32 (9216..50000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 3 }
|
|
|
|
rbMeterEir OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 4 }
|
|
|
|
rbMeterEbs OBJECT-TYPE
|
|
SYNTAX Integer32 (9216..100000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 5 }
|
|
|
|
|
|
rbMeterColorMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
color-aware(1),
|
|
color-blind(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 6 }
|
|
|
|
rbMeterRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbMeterEntry 7 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge event config
|
|
-- ===========================================================
|
|
|
|
rbEventConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbEventConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeEventConfig 1 }
|
|
|
|
rbEventConfigEntry OBJECT-TYPE
|
|
SYNTAX RbEventConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbEventConfigIndex }
|
|
::= { rbEventConfigTable 1 }
|
|
|
|
RbEventConfigEntry ::= SEQUENCE {
|
|
rbEventConfigIndex Integer32,
|
|
rbEventConfigId OCTET STRING,
|
|
rbEventConfigMask TruthValue
|
|
}
|
|
|
|
rbEventConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEventConfigEntry 1 }
|
|
|
|
rbEventConfigId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEventConfigEntry 2 }
|
|
|
|
rbEventConfigMask OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbEventConfigEntry 3 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge system extension
|
|
-- ===========================================================
|
|
|
|
rbRfEncryption OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeEncryption 1 }
|
|
|
|
|
|
rbRfStaticKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeEncryption 2 }
|
|
|
|
|
|
rbRfAuthenticationString OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeEncryption 3 }
|
|
|
|
-- ===========================================================
|
|
-- ===========================================================
|
|
|
|
rbAgentReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSnmp 1 }
|
|
|
|
|
|
rbAgentWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSnmp 2 }
|
|
|
|
rbAgentSnmpVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
v2c(2),
|
|
v3(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSnmp 3 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- ===========================================================
|
|
|
|
rbSysFileOperationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbSysFileOperationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table has a permanent row with index 1. It is not creatable, the fileSessionRowStatus
|
|
is used to activate the file operation process if necessary variables are assigned."
|
|
::= { radioBridgeRoot 18 }
|
|
|
|
rbSysFileOperationEntry OBJECT-TYPE
|
|
SYNTAX RbSysFileOperationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { fileSessionIndex }
|
|
::= { rbSysFileOperationTable 1 }
|
|
|
|
RbSysFileOperationEntry ::= SEQUENCE {
|
|
fileSessionIndex Integer32,
|
|
fileSessionCommand INTEGER,
|
|
fileSessionLocalParams DisplayString,
|
|
fileSessionRemotePath DisplayString,
|
|
|
|
fileSessionProtocol INTEGER,
|
|
fileSessionServer DisplayString,
|
|
fileSessionUser DisplayString,
|
|
fileSessionPassword DisplayString,
|
|
|
|
fileSessionResult DisplayString,
|
|
fileSessionState INTEGER,
|
|
fileSessionRowStatus RowStatus
|
|
}
|
|
|
|
fileSessionIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 1 }
|
|
|
|
fileSessionCommand OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
copySwFromRemote(1),
|
|
copyLicenseFromRemote(2),
|
|
copyFileFromRemoteToLocal(3),
|
|
copyFileFromLocalToRemote(4),
|
|
acceptSw(5),
|
|
runSw(6),
|
|
copyDirToRemote(7),
|
|
copyEventLog(9),
|
|
copyUserActivityLog(10),
|
|
runScript(11),
|
|
copyInventory(12),
|
|
copyStatsHistory(13)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 2 }
|
|
|
|
fileSessionLocalParams OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 3 }
|
|
|
|
fileSessionRemotePath OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 4 }
|
|
|
|
fileSessionServer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 5 }
|
|
|
|
fileSessionUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 6 }
|
|
|
|
fileSessionPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 7 }
|
|
|
|
fileSessionResult OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 8 }
|
|
|
|
fileSessionState OBJECT-TYPE
|
|
SYNTAX INTEGER { running(1), terminated-ok(2), terminated-error(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 9 }
|
|
|
|
fileSessionRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"see rbSysFileOperationTable description"
|
|
::= { rbSysFileOperationEntry 10 }
|
|
|
|
fileSessionProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER { ftp(1), sftp(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSysFileOperationEntry 13 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge files operation
|
|
-- ===========================================================
|
|
|
|
|
|
rbLldpPortExtensionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbLldpPortExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"extends lldpV2PortConfigTable"
|
|
::= { radioBridgeLldp 1 }
|
|
|
|
rbLldpPortExtensionEntry OBJECT-TYPE
|
|
SYNTAX RbLldpPortExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbLldpPortIfIndex, rbLldpPortDestAddressIndex }
|
|
::= { rbLldpPortExtensionTable 1 }
|
|
|
|
RbLldpPortExtensionEntry ::= SEQUENCE
|
|
{
|
|
rbLldpPortIfIndex InterfaceIndex,
|
|
rbLldpPortDestAddressIndex Unsigned32,
|
|
rbLldpPortVid Unsigned32
|
|
}
|
|
|
|
rbLldpPortIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"equal to lldpV2PortConfigIfIndex from RbLldpPortExtensionEntry"
|
|
::= { rbLldpPortExtensionEntry 1 }
|
|
|
|
rbLldpPortDestAddressIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"equal to lldpV2PortConfigDestAddressIndex from RbLldpPortExtensionEntry"
|
|
::= { rbLldpPortExtensionEntry 2 }
|
|
|
|
|
|
rbLldpPortVid OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbLldpPortExtensionEntry 3 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge WRED
|
|
-- ===========================================================
|
|
|
|
rbWredTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbWredEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeWred 1 }
|
|
|
|
rbWredEntry OBJECT-TYPE
|
|
SYNTAX RbWredEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbWredId }
|
|
::= { rbWredTable 1 }
|
|
|
|
RbWredEntry ::= SEQUENCE
|
|
{
|
|
rbWredId Integer32,
|
|
rbWredNfactor Integer32,
|
|
rbWredMinThreshold Integer32,
|
|
rbWredMaxThreshold Integer32,
|
|
rbWredProbability Integer32,
|
|
rbWredMinThresholdYellow Integer32,
|
|
rbWredMaxThresholdYellow Integer32,
|
|
rbWredProbabilityYellow Integer32,
|
|
|
|
rbWredRowStatus RowStatus
|
|
}
|
|
|
|
rbWredId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 1 }
|
|
|
|
rbWredNfactor OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 2 }
|
|
|
|
rbWredMinThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 3 }
|
|
|
|
rbWredMaxThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 4 }
|
|
|
|
rbWredProbability OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 5 }
|
|
|
|
rbWredMinThresholdYellow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 6 }
|
|
|
|
rbWredMaxThresholdYellow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 7 }
|
|
|
|
rbWredProbabilityYellow OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 8 }
|
|
|
|
rbWredRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbWredEntry 9 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge authentication
|
|
-- ===========================================================
|
|
|
|
rbAuthServersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbAuthServersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeAuthentication 1 }
|
|
|
|
rbAuthServersEntry OBJECT-TYPE
|
|
SYNTAX RbAuthServersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbAuthServerId }
|
|
::= { rbAuthServersTable 1 }
|
|
|
|
RbAuthServersEntry ::= SEQUENCE
|
|
{
|
|
rbAuthServerId Integer32,
|
|
rbAuthServerIpAddress IpAddress,
|
|
rbAuthServerPort Integer32,
|
|
rbAuthServerRowStatus RowStatus
|
|
}
|
|
|
|
rbAuthServerId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbAuthServersEntry 1 }
|
|
|
|
rbAuthServerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbAuthServersEntry 2 }
|
|
|
|
rbAuthServerPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbAuthServersEntry 3 }
|
|
|
|
rbAuthServerRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbAuthServersEntry 4 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge Quota
|
|
-- ===========================================================
|
|
|
|
rbFdbQuotaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbFdbQuotaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQuota 1 }
|
|
|
|
rbFdbQuotaEntry OBJECT-TYPE
|
|
SYNTAX RbFdbQuotaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbFdbQuotaId }
|
|
::= { rbFdbQuotaTable 1 }
|
|
|
|
RbFdbQuotaEntry ::= SEQUENCE
|
|
{
|
|
rbFdbQuotaId Integer32,
|
|
rbFdbQuotaSize Integer32,
|
|
rbFdbQuotaRowStatus RowStatus,
|
|
|
|
rbFdbQuotaMaxSize Counter64,
|
|
rbFdbQuotaUsedEntries Counter64,
|
|
rbFdbQuotaStaticEntries Counter64,
|
|
rbFdbQuotaDynamicEntries Counter64,
|
|
rbFdbQuotaUnusedEntries Counter64
|
|
}
|
|
|
|
|
|
rbFdbQuotaId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 1 }
|
|
|
|
|
|
rbFdbQuotaSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4000)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 2 }
|
|
|
|
rbFdbQuotaRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 3 }
|
|
|
|
|
|
rbFdbQuotaMaxSize OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 11 }
|
|
|
|
rbFdbQuotaUsedEntries OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 12 }
|
|
|
|
rbFdbQuotaStaticEntries OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 13 }
|
|
|
|
rbFdbQuotaDynamicEntries OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 14 }
|
|
|
|
rbFdbQuotaUnusedEntries OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbQuotaEntry 15 }
|
|
|
|
|
|
|
|
rbFdbEvcQuotaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbFdbEvcQuotaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeQuota 2 }
|
|
|
|
rbFdbEvcQuotaEntry OBJECT-TYPE
|
|
SYNTAX RbFdbEvcQuotaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbFdbEvcQuotaId }
|
|
::= { rbFdbEvcQuotaTable 1 }
|
|
|
|
|
|
RbFdbEvcQuotaEntry ::= SEQUENCE
|
|
{
|
|
rbFdbEvcQuotaId Integer32,
|
|
rbRefEvcId Integer32,
|
|
rbRefFdbQuotaId Integer32,
|
|
rbFdbEvcQuotaRowStatus RowStatus
|
|
}
|
|
|
|
rbFdbEvcQuotaId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbEvcQuotaEntry 1 }
|
|
|
|
rbRefEvcId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbEvcQuotaEntry 2 }
|
|
|
|
rbRefFdbQuotaId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbEvcQuotaEntry 3 }
|
|
|
|
rbFdbEvcQuotaRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbEvcQuotaEntry 4 }
|
|
|
|
|
|
|
|
rbFdbExtensionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbFdbExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"extends the ieee8021QBridgeTpFdbTable"
|
|
::= { radioBridgeQuota 3 }
|
|
|
|
rbFdbExtensionEntry OBJECT-TYPE
|
|
SYNTAX RbFdbExtensionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing additional management information applicable to a fdb entry."
|
|
AUGMENTS { ieee8021QBridgeTpFdbEntry }
|
|
::= { rbFdbExtensionTable 1 }
|
|
|
|
RbFdbExtensionEntry ::= SEQUENCE
|
|
{
|
|
rbRefExtFdbQuotaId Integer32
|
|
}
|
|
|
|
rbRefExtFdbQuotaId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbFdbExtensionEntry 1 }
|
|
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge PCP profile
|
|
-- ===========================================================
|
|
|
|
rbPcpWriteProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbPcpWriteProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgePcpProfile 1 }
|
|
|
|
rbPcpWriteProfileEntry OBJECT-TYPE
|
|
SYNTAX RbPcpWriteProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbPcpWriteProfileId }
|
|
::= { rbPcpWriteProfileTable 1 }
|
|
|
|
|
|
RbPcpWriteProfileEntry ::= SEQUENCE
|
|
{
|
|
rbPcpWriteProfileId Integer32,
|
|
rbPcpWriteProfilePcp OCTET STRING,
|
|
rbPcpWriteProfileRowStatus RowStatus
|
|
}
|
|
|
|
|
|
rbPcpWriteProfileId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPcpWriteProfileEntry 1 }
|
|
|
|
|
|
rbPcpWriteProfilePcp OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPcpWriteProfileEntry 2 }
|
|
|
|
|
|
rbPcpWriteProfileRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbPcpWriteProfileEntry 3 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge SysLog
|
|
-- ===========================================================
|
|
|
|
rbSyslogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbSyslogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeSyslog 1 }
|
|
|
|
rbSyslogEntry OBJECT-TYPE
|
|
SYNTAX RbSyslogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbSyslogId }
|
|
::= { rbSyslogTable 1 }
|
|
|
|
|
|
RbSyslogEntry ::= SEQUENCE
|
|
{
|
|
rbSyslogId Integer32,
|
|
rbSyslogServerIp IpAddress,
|
|
rbSyslogRowStatus RowStatus
|
|
}
|
|
|
|
rbSyslogId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSyslogEntry 1 }
|
|
|
|
rbSyslogServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSyslogEntry 2 }
|
|
|
|
rbSyslogRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbSyslogEntry 3 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge NTP
|
|
-- ===========================================================
|
|
|
|
rbNtpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbNtpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeNtp 1 }
|
|
|
|
rbNtpEntry OBJECT-TYPE
|
|
SYNTAX RbNtpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { rbNtpId }
|
|
::= { rbNtpTable 1 }
|
|
|
|
|
|
RbNtpEntry ::= SEQUENCE
|
|
{
|
|
rbNtpId Integer32,
|
|
rbNtpServerIp IpAddress,
|
|
rbNtpSecondaryServerIp IpAddress,
|
|
rbNtpTmz Integer32,
|
|
rbNtpRowStatus RowStatus
|
|
}
|
|
|
|
rbNtpId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbNtpEntry 1 }
|
|
|
|
rbNtpServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbNtpEntry 2 }
|
|
|
|
rbNtpSecondaryServerIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbNtpEntry 3 }
|
|
|
|
rbNtpTmz OBJECT-TYPE
|
|
SYNTAX Integer32 (-12..14)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbNtpEntry 4 }
|
|
|
|
rbNtpRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbNtpEntry 5 }
|
|
|
|
-- ===========================================================
|
|
-- Radio Bridge license
|
|
-- ===========================================================
|
|
|
|
rbLicenseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RbLicenseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { radioBridgeLicense 1 }
|
|
|
|
rbLicenseEntry OBJECT-TYPE
|
|
SYNTAX RbLicenseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { IMPLIED rbLicenseId }
|
|
::= { rbLicenseTable 1 }
|
|
|
|
|
|
RbLicenseEntry ::= SEQUENCE
|
|
{
|
|
rbLicenseId DisplayString,
|
|
rbLicenseCurrentValue INTEGER,
|
|
rbLicenseMaxValue INTEGER
|
|
}
|
|
|
|
rbLicenseId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..32))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbLicenseEntry 1 }
|
|
|
|
rbLicenseCurrentValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"for data-rate means data rate value, for enable similar to TruthValue"
|
|
::= { rbLicenseEntry 2 }
|
|
|
|
rbLicenseMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { rbLicenseEntry 3 }
|
|
|
|
|
|
END
|
|
|