STORMSHIELD-SERVICES-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI
DisplayString FROM RFC1213-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
stormshieldMIB FROM STORMSHIELD-SMI-MIB;
snsServices MODULE-IDENTITY
LAST-UPDATED "201702200000Z"
ORGANIZATION "Stormshield"
CONTACT-INFO
"Customer Support
22 rue du Gouverneur General Eboue
92130 Issy-les-Moulineaux
FRANCE
Tel: +33 (0)9 69 32 96 29
E-mail: support@stormshield.eu
http://www.stormshield.eu"
DESCRIPTION "stormshield services"
REVISION "201702200000Z"
DESCRIPTION "Initial"
::= { stormshieldMIB 7 }
snsServicesTable OBJECT-TYPE
SYNTAX SEQUENCE OF SnsServicesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of running services"
::= { snsServices 1 }
snsServicesEntry OBJECT-TYPE
SYNTAX SnsServicesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in the snsServicesTable holds a set of information
(Service name, status, and uptime)."
INDEX { snsServicesIndex }
::= { snsServicesTable 1 }
SnsServicesEntry ::= SEQUENCE {
snsServicesIndex INTEGER,
snsServicesName SnmpAdminString,
snsServicesState Integer32,
snsServicesUptime Integer32
}
snsServicesIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for the table. Its value
ranges between 1 and 65535 and may not be contigous.
the index has no other meaning but a pure index"
::= { snsServicesEntry 1 }
snsServicesName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Service name"
::= { snsServicesEntry 2 }
snsServicesState OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State value can be 0/1 according as the service is down/up"
::= { snsServicesEntry 3 }
snsServicesUptime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Uptime"
::= { snsServicesEntry 4 }
END