275 lines
7.4 KiB
Plaintext
275 lines
7.4 KiB
Plaintext
-- *****************************************************************
|
|
-- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information
|
|
--
|
|
-- October 26 2001, Software LAB
|
|
--
|
|
-- Copyright (c) 1993-2019 Super Micro Computer, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Gauge32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
smHealth
|
|
FROM SUPERMICRO-SMI;
|
|
|
|
smHealthMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200110260000Z"
|
|
ORGANIZATION "Super Micro Computer Inc."
|
|
CONTACT-INFO
|
|
" Software Lab
|
|
|
|
Postal: 980 Rock Avenue
|
|
San Jose, CA 95131
|
|
USA
|
|
|
|
Tel: +1 408 503 8000
|
|
|
|
E-mail: SoftLab@supermicro.com"
|
|
DESCRIPTION
|
|
"MIB module for monitoring health information"
|
|
::= { smHealth 1 }
|
|
|
|
SMHealthInfoTypes ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the different types of health information that
|
|
may be present in a managed device. The following health
|
|
information types are currently predefined:
|
|
0: fan speed
|
|
1: voltage
|
|
2: temperature
|
|
"
|
|
SYNTAX Integer32 (0..64)
|
|
|
|
smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 }
|
|
|
|
smHealthMonitorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SMHealthMonitorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of health monitoring entries."
|
|
::= { smHealthObjects 1 }
|
|
|
|
-- ================
|
|
smHealthMonitorEntry OBJECT-TYPE
|
|
SYNTAX SMHealthMonitorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the health monitoring table.
|
|
Entries cannot be created or deleted via SNMP operations."
|
|
INDEX { smHealthMonitorIndex }
|
|
::= { smHealthMonitorTable 1 }
|
|
|
|
SMHealthMonitorEntry ::=
|
|
SEQUENCE {
|
|
smHealthMonitorIndex Integer32,
|
|
smHealthMonitorName DisplayString,
|
|
smHealthMonitorType SMHealthInfoTypes,
|
|
smHealthMonitorReading Integer32,
|
|
smHealthMonitorHighLimit Integer32,
|
|
smHealthMonitorLowLimit Integer32,
|
|
smHealthMonitorMaxReading Integer32,
|
|
smHealthMonitorMinReading Integer32,
|
|
smHealthMonitorDivisor Integer32,
|
|
smHealthMonitorMonitor TruthValue,
|
|
smHealthMonitorReadingUnit DisplayString,
|
|
smHealthMonitorStatus Integer32
|
|
}
|
|
|
|
smHealthMonitorIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique value identifies this Monitor device."
|
|
::= { smHealthMonitorEntry 1 }
|
|
|
|
smHealthMonitorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual full name assigned to the Monitor device.
|
|
This object is suitable for output to a human operator."
|
|
::= { smHealthMonitorEntry 2 }
|
|
|
|
smHealthMonitorType OBJECT-TYPE
|
|
SYNTAX SMHealthInfoTypes
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies this Monitor device type."
|
|
::= { smHealthMonitorEntry 3 }
|
|
|
|
smHealthMonitorReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the reading value for the Monitor device that are currently in use on the managed device.
|
|
FAN readings are displayed in RPM.
|
|
Voltage readings are displayed in mV.
|
|
Temperture readings are displayed in Celsius."
|
|
::= { smHealthMonitorEntry 4 }
|
|
|
|
smHealthMonitorHighLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the the High limit for the Monitor device that are currently in use on the managed device.
|
|
This is applied to Temperature and Voltage devices only.
|
|
Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius."
|
|
::= { smHealthMonitorEntry 5 }
|
|
|
|
smHealthMonitorLowLimit OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the value for the Low limitation for the Monitor device that are currently in use on the managed device.
|
|
FAN limit is displayed in RPM, Voltage limit is displayed in mV, and Temperture limit is displayed in Celsius."
|
|
::= { smHealthMonitorEntry 6 }
|
|
|
|
smHealthMonitorMaxReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the value for the possible Maximum reading value for the Monitor device that are currently in use on the managed device.
|
|
FAN readings are displayed in RPM.
|
|
Voltage readings are displayed in mV.
|
|
Temperture readings are in Celsius."
|
|
::= { smHealthMonitorEntry 7 }
|
|
|
|
smHealthMonitorMinReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the value for the possible Minimum reading value for the Monitor device that are currently in use on the managed device.
|
|
FAN readings are displayed in RPM.
|
|
Voltage readings are displayed in mV.
|
|
Temperture readings are displayed in Celsius."
|
|
::= { smHealthMonitorEntry 8 }
|
|
|
|
smHealthMonitorDivisor OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the value for the Divisor for the Fan device that are currently in use on the managed device.
|
|
This is applied to Fan devices only."
|
|
::= { smHealthMonitorEntry 9 }
|
|
|
|
smHealthMonitorMonitor OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the monitoring status for the Fan device that are currently in use on the managed device.
|
|
0 = not monitored, 1 = monitored."
|
|
::= { smHealthMonitorEntry 10 }
|
|
|
|
smHealthMonitorReadingUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the reading unit of the monitor device."
|
|
::= { smHealthMonitorEntry 11 }
|
|
|
|
smHealthMonitorStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the status of the monitor device. Values:
|
|
0: OK
|
|
1: Warning
|
|
2: Critical
|
|
"
|
|
::= { smHealthMonitorEntry 12 }
|
|
|
|
-- notifications
|
|
|
|
smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 }
|
|
|
|
-- (no notifications are currently defined)
|
|
|
|
|
|
-- conformance information
|
|
|
|
smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 }
|
|
smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 }
|
|
smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 }
|
|
|
|
|
|
-- compliance statements
|
|
|
|
smHealthCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
the Supermicro Health Monitoring MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { smHealthMonitorGroup}
|
|
::= { smHealthCompliances 1 }
|
|
|
|
|
|
-- units of conformance
|
|
|
|
smHealthMonitorGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
smHealthMonitorType,
|
|
smHealthMonitorName,
|
|
smHealthMonitorReading,
|
|
smHealthMonitorHighLimit,
|
|
smHealthMonitorLowLimit,
|
|
smHealthMonitorMaxReading,
|
|
smHealthMonitorMinReading,
|
|
smHealthMonitorMonitor
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing Monitor devices."
|
|
::= { smHealthGroups 1 }
|
|
|
|
smHealthAllinoneStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the all-in-one status of the monitoring items. Values:
|
|
0: OK
|
|
1: Warning
|
|
2: Critical
|
|
"
|
|
::= { smHealth 2 }
|
|
|
|
smHealthAllinoneMsg OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The all-in-one status message of the monitoring items."
|
|
::= { smHealth 3 }
|
|
|
|
END
|