-- ** Filename: PRVT-CES-MIB.mib
 | 
						||
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
 | 
						||
-- ** Purpose: Private MIB
 | 
						||
-- *********************************************************************
 | 
						||
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
 | 
						||
-- WARNING:
 | 
						||
--
 | 
						||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
 | 
						||
--
 | 
						||
-- This file is the property of BATM Advanced Communications.
 | 
						||
-- BATM Advanced Communications retains all title and
 | 
						||
-- ownership in the Specification, including any revisions.
 | 
						||
 | 
						||
-- BATM Advanced Communications grants all interested parties a non-exclusive
 | 
						||
-- license to use and distribute an unmodified copy of this
 | 
						||
-- Specification in connection with management of BATM Advanced Communications
 | 
						||
-- and Telco Systems products, and without fee, provided that the following
 | 
						||
-- conditions are met:
 | 
						||
-- 1. Redistributions of this specification must retain the above copyright
 | 
						||
-- notice, this list of conditions and the following disclaimer.
 | 
						||
-- 2. Redistributions in binary form must reproduce the above copyright
 | 
						||
-- notice, this list of conditions and the following disclaimer in the
 | 
						||
-- documentation and/or other materials provided with the distribution.
 | 
						||
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
 | 
						||
-- or promote products derived from this specification without specific prior written
 | 
						||
-- permission.
 | 
						||
--
 | 
						||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
 | 
						||
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
 | 
						||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
 | 
						||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
 | 
						||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
 | 
						||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
 | 
						||
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
 | 
						||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
 | 
						||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
 | 
						||
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
 | 
						||
PRVT-CES-MIB DEFINITIONS ::= BEGIN
 | 
						||
 | 
						||
IMPORTS
 | 
						||
MODULE-IDENTITY,
 | 
						||
OBJECT-TYPE,
 | 
						||
IpAddress,
 | 
						||
Gauge32,
 | 
						||
Integer32,
 | 
						||
Unsigned32,
 | 
						||
NOTIFICATION-TYPE
 | 
						||
FROM SNMPv2-SMI
 | 
						||
 | 
						||
TimeStamp
 | 
						||
FROM SNMPv2-TC
 | 
						||
 | 
						||
dsx1ConfigEntry
 | 
						||
FROM DS1-MIB
 | 
						||
 | 
						||
TEXTUAL-CONVENTION
 | 
						||
FROM SNMPv2-TC
 | 
						||
 | 
						||
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
 | 
						||
OBJECT-GROUP
 | 
						||
FROM SNMPv2-CONF
 | 
						||
 | 
						||
switch
 | 
						||
FROM PRVT-SWITCH-MIB;
 | 
						||
 | 
						||
prvtCESMib MODULE-IDENTITY
 | 
						||
LAST-UPDATED "200905180000Z"
 | 
						||
ORGANIZATION "BATM Advanced Communication"
 | 
						||
CONTACT-INFO
 | 
						||
"BATM/Telco Systems Support team
 | 
						||
Email:
 | 
						||
For North America: techsupport@telco.com
 | 
						||
For North Europe: support@batm.de, info@batm.de
 | 
						||
For the rest of the world: techsupport@telco.com"
 | 
						||
 | 
						||
DESCRIPTION
 | 
						||
"This module includes configuration parameters for DS1 modules not included in
 | 
						||
DS1-MIB."
 | 
						||
 | 
						||
-- revision history
 | 
						||
REVISION "200905180000Z"
 | 
						||
DESCRIPTION
 | 
						||
"OC3 Alarm Enhacements"
 | 
						||
 | 
						||
REVISION "200905140000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Add prvtCESApsTable"
 | 
						||
 | 
						||
REVISION "200905050000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Add prvtCESUpdateFirmwareTable"
 | 
						||
 | 
						||
REVISION "200903190000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Add new objects prvtCESServiceClock, prvtCESModuleServiceClock"
 | 
						||
 | 
						||
REVISION "200902250000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Add prvtCESCICTable, prvtCESCICMappTable,
 | 
						||
prvtCESModulePolicyLopsEnter, prvtCESModulePolicyLopsExit "
 | 
						||
REVISION "200902160000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Modified values for objects
 | 
						||
prvtCESModulePolicyLops, prvtCESModulePolicyRbit,
 | 
						||
prvtCESModulePolicyRd"
 | 
						||
REVISION "200806190000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Added new objects
 | 
						||
prvtCESClearPortStatistics, prvtCESModuleClearCircuitStatistics,
 | 
						||
prvtCESModuleLbit, prvtCESModulePolicyLops,
 | 
						||
prvtCESModulePolicyLbit, prvtCESModulePolicyRbit,
 | 
						||
prvtCESModulePolicyRd, prvtCESModulePolicyIdlePattern,
 | 
						||
prvtCESModulePolicyIdleSignalling"
 | 
						||
 | 
						||
REVISION "200603070000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Added an additional port index to the alarm table."
 | 
						||
 | 
						||
REVISION "200602230000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Added the TCA alarms table objects and the TCA alarm trap."
 | 
						||
 | 
						||
REVISION "200503110000Z"
 | 
						||
DESCRIPTION
 | 
						||
"Initial version."
 | 
						||
 | 
						||
::= { switch 111 }
 | 
						||
 | 
						||
--
 | 
						||
-- Variable Type definitions
 | 
						||
--
 | 
						||
 | 
						||
ConfigAction ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This value is used to specify what is to be done with unapplied CES module configuration."
 | 
						||
SYNTAX INTEGER {
 | 
						||
noop(1),
 | 
						||
applyConfiguration(2),
 | 
						||
rejectConfiguration(3),
 | 
						||
restart(4)
 | 
						||
}
 | 
						||
 | 
						||
E1Impedance ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This value is used to configure E1 line type termination impedance."
 | 
						||
SYNTAX INTEGER {
 | 
						||
notApplicable(0),
 | 
						||
e1-75ohm(1),
 | 
						||
e1-75hrl(2),
 | 
						||
e1-120ohm(3),
 | 
						||
e1-120hrl(4)
 | 
						||
}
 | 
						||
 | 
						||
T1LongCableLength ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This value is used to configure T1 long cable length."
 | 
						||
SYNTAX INTEGER {
 | 
						||
notApplicable (1),
 | 
						||
neg75dB (2),
 | 
						||
neg15dB (3),
 | 
						||
neg225dB (4),
 | 
						||
zerodB (5)
 | 
						||
}
 | 
						||
 | 
						||
T1GainLimit ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This value is used to configure T1 type Tx or Rx gain limit."
 | 
						||
SYNTAX INTEGER {
 | 
						||
notApplicable(0),
 | 
						||
none(1),
 | 
						||
gain30(2),
 | 
						||
gain36(3)
 | 
						||
}
 | 
						||
 | 
						||
CESLineType ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This value is used to configure the line mode common for all TDM ports of the module."
 | 
						||
SYNTAX INTEGER {
 | 
						||
e1(1),
 | 
						||
t1(2),
 | 
						||
e1-sdh(3),
 | 
						||
t1-sdh(4),
 | 
						||
t1-sonet(5)
 | 
						||
}
 | 
						||
 | 
						||
ServiceClock ::= TEXTUAL-CONVENTION
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This values are used to configure transmit clock as one of this modes."
 | 
						||
SYNTAX INTEGER{
 | 
						||
notAplicable(0),
 | 
						||
loopTiming (1),
 | 
						||
localTiming (2),
 | 
						||
adaptive	(3),
 | 
						||
differntial (4)
 | 
						||
}
 | 
						||
 | 
						||
prvtCESNotifications OBJECT IDENTIFIER ::= { prvtCESMib 0 }
 | 
						||
prvtCESObjects OBJECT IDENTIFIER ::= { prvtCESMib 1 }
 | 
						||
prvtCESConformance OBJECT IDENTIFIER ::= { prvtCESMib 2 }
 | 
						||
 | 
						||
--
 | 
						||
-- ces objects
 | 
						||
--
 | 
						||
prvtCESDsx1ExtTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESDsx1ExtEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable."
 | 
						||
::= { prvtCESObjects 1 }
 | 
						||
 | 
						||
prvtCESDsx1ExtEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESDsx1ExtEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESDsx1ExtEntry"
 | 
						||
AUGMENTS { dsx1ConfigEntry }
 | 
						||
::= { prvtCESDsx1ExtTable 1 }
 | 
						||
 | 
						||
PrvtCESDsx1ExtEntry ::= SEQUENCE {
 | 
						||
prvtCESE1Impedance E1Impedance,
 | 
						||
prvtCEST1GainLimit T1GainLimit,
 | 
						||
prvtCESPortShutdown INTEGER,
 | 
						||
prvtCESPortLineType INTEGER,
 | 
						||
prvtCEST1LongCableLength T1LongCableLength,
 | 
						||
prvtCESPortOperStatus INTEGER,
 | 
						||
prvtCESClearPortStatistics INTEGER,
 | 
						||
prvtCESServiceClock ServiceClock
 | 
						||
}
 | 
						||
 | 
						||
prvtCESE1Impedance OBJECT-TYPE
 | 
						||
SYNTAX E1Impedance
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This object configures temination impedance for TDM ports if the line type is E1."
 | 
						||
::= { prvtCESDsx1ExtEntry 1 }
 | 
						||
 | 
						||
prvtCEST1GainLimit OBJECT-TYPE
 | 
						||
SYNTAX T1GainLimit
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This object configures Tx or Rx gain limit for TDM ports if the line type is T1."
 | 
						||
::= { prvtCESDsx1ExtEntry 2 }
 | 
						||
 | 
						||
prvtCESPortShutdown OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable(1),
 | 
						||
disable(2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Shutdown TDM port."
 | 
						||
::= { prvtCESDsx1ExtEntry 3 }
 | 
						||
 | 
						||
prvtCESPortLineType OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
other(1),
 | 
						||
dsx1ESF(2),
 | 
						||
dsx1D4(3),
 | 
						||
dsx1E1(4),
 | 
						||
dsx1E1CRC(5),
 | 
						||
dsx1E1MF(6),
 | 
						||
dsx1E1CRCMF(7),
 | 
						||
dsx1Unframed(8),
 | 
						||
dsx1E1Unframed(9),
 | 
						||
dsx1DS2M12(10),
 | 
						||
dsx1E2(11),
 | 
						||
dsx1E1Q50(12),
 | 
						||
dsx1E1Q50CRC(13),
 | 
						||
dsx1SFCAS(14),
 | 
						||
dsx1ESFCAS(15),
 | 
						||
notApplicable(16)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Additional line types. For reference see object dsx1LineType"
 | 
						||
::= { prvtCESDsx1ExtEntry 4 }
 | 
						||
 | 
						||
prvtCEST1LongCableLength OBJECT-TYPE
 | 
						||
SYNTAX T1LongCableLength
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Long cable length options for T1 mode."
 | 
						||
::= { prvtCESDsx1ExtEntry 5 }
 | 
						||
 | 
						||
prvtCESPortOperStatus OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
up(1),
 | 
						||
down(2),
 | 
						||
testing(3),
 | 
						||
unknown(4),
 | 
						||
dormant(5),
 | 
						||
notPresent(6),
 | 
						||
lowerlayerDown(7)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"TDM link state."
 | 
						||
::= { prvtCESDsx1ExtEntry 6 }
 | 
						||
 | 
						||
prvtCESClearPortStatistics OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none ( 0 ),
 | 
						||
clear ( 1 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Clear port statistics."
 | 
						||
::= { prvtCESDsx1ExtEntry 7 }
 | 
						||
 | 
						||
prvtCESServiceClock OBJECT-TYPE
 | 
						||
SYNTAX ServiceClock
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Service Clock available only for DS1 interface."
 | 
						||
::= { prvtCESDsx1ExtEntry 8 }
 | 
						||
 | 
						||
prvtCESUnappTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESUnappEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table displays CES module configuration which will take effect
 | 
						||
after prvtCESModuleConf is set to applyConfiguration(2)."
 | 
						||
::= { prvtCESObjects 3 }
 | 
						||
 | 
						||
prvtCESUnappEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESUnappEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESUnappEntry"
 | 
						||
AUGMENTS { dsx1ConfigEntry }
 | 
						||
::= { prvtCESUnappTable 1 }
 | 
						||
 | 
						||
PrvtCESUnappEntry ::= SEQUENCE {
 | 
						||
prvtCESUnappLineType INTEGER,
 | 
						||
prvtCESUnappLineCoding INTEGER,
 | 
						||
prvtCESUnappLoopbackConfig INTEGER,
 | 
						||
prvtCESUnappSignalMode INTEGER,
 | 
						||
prvtCESUnappTransmitClockSource INTEGER,
 | 
						||
prvtCESUnappTransmitClockBackup INTEGER,
 | 
						||
prvtCESUnappLineLength Integer32,
 | 
						||
prvtCESUnappLineMode INTEGER,
 | 
						||
prvtCESUnappLineBuildOut INTEGER,
 | 
						||
prvtCESUnappE1Impedance E1Impedance,
 | 
						||
prvtCESUnappT1GainLimit T1GainLimit,
 | 
						||
prvtCESUnappIPAddress IpAddress,
 | 
						||
prvtCESUnappIPAddressMask IpAddress,
 | 
						||
prvtCESUnappGateway IpAddress
 | 
						||
}
 | 
						||
 | 
						||
prvtCESUnappLineType OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
other(1),
 | 
						||
dsx1ESF(2),
 | 
						||
dsx1D4(3),
 | 
						||
dsx1E1(4),
 | 
						||
dsx1E1CRC(5),
 | 
						||
dsx1E1MF(6),
 | 
						||
dsx1E1CRCMF(7),
 | 
						||
dsx1Unframed(8),
 | 
						||
dsx1E1Unframed(9),
 | 
						||
dsx1DS2M12(10),
 | 
						||
dsx1E2(11),
 | 
						||
dsx1E1Q50(12),
 | 
						||
dsx1E1Q50CRC(13)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LineType before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 1 }
 | 
						||
 | 
						||
prvtCESUnappLineCoding OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
dsx1JBZS (1),
 | 
						||
dsx1B8ZS (2),
 | 
						||
dsx1HDB3 (3),
 | 
						||
dsx1ZBTSI (4),
 | 
						||
dsx1AMI (5),
 | 
						||
other(6),
 | 
						||
dsx1B6ZS(7)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LineCoding before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 2 }
 | 
						||
 | 
						||
prvtCESUnappLoopbackConfig OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
dsx1NoLoop(1),
 | 
						||
dsx1PayloadLoop(2),
 | 
						||
dsx1LineLoop(3),
 | 
						||
dsx1OtherLoop(4),
 | 
						||
dsx1InwardLoop(5),
 | 
						||
dsx1DualLoop(6)
 | 
						||
}
 | 
						||
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LoopbackConfig before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 3 }
 | 
						||
 | 
						||
prvtCESUnappSignalMode OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none (1),
 | 
						||
robbedBit (2),
 | 
						||
bitOriented (3),
 | 
						||
messageOriented (4),
 | 
						||
other (5)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1SignalMode before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 4 }
 | 
						||
 | 
						||
prvtCESUnappTransmitClockSource OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
loopTiming(1),
 | 
						||
localTiming(2),
 | 
						||
throughTiming(3),
 | 
						||
adaptive (4),
 | 
						||
external-port (5)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1TransmitClockSource before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 5 }
 | 
						||
 | 
						||
prvtCESUnappTransmitClockBackup OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable (1),
 | 
						||
disable(2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1TransmitClockBackup before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 6 }
 | 
						||
 | 
						||
prvtCESUnappLineLength OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (0..64000)
 | 
						||
UNITS "meters"
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LineLength before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 7 }
 | 
						||
 | 
						||
prvtCESUnappLineMode OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
csu(1),
 | 
						||
dsu(2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LineMode before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 8 }
 | 
						||
 | 
						||
prvtCESUnappLineBuildOut OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
notApplicable (1),
 | 
						||
neg75dB (2),
 | 
						||
neg15dB (3),
 | 
						||
neg225dB (4),
 | 
						||
zerodB (5)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of dsx1LineBuildOut before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 9 }
 | 
						||
 | 
						||
prvtCESUnappE1Impedance OBJECT-TYPE
 | 
						||
SYNTAX E1Impedance
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of prvtCESE1Impedance before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 10 }
 | 
						||
 | 
						||
prvtCESUnappT1GainLimit OBJECT-TYPE
 | 
						||
SYNTAX T1GainLimit
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of prvtCEST1GainLimit before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 11 }
 | 
						||
 | 
						||
prvtCESUnappIPAddress OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The CES Module IP address before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 12 }
 | 
						||
 | 
						||
prvtCESUnappIPAddressMask OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The CES Module IP address mask before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 13 }
 | 
						||
 | 
						||
prvtCESUnappGateway OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The CES Module Gateway before configuration is applied."
 | 
						||
::= { prvtCESUnappEntry 14 }
 | 
						||
 | 
						||
prvtCESModuleConfTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESModuleConfEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains object for configuring options that are applied to the entire module."
 | 
						||
::= { prvtCESObjects 2 }
 | 
						||
 | 
						||
prvtCESModuleConfEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESModuleConfEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESModuleConfEntry"
 | 
						||
INDEX {prvtCESModuleIndex}
 | 
						||
::= { prvtCESModuleConfTable 1 }
 | 
						||
 | 
						||
PrvtCESModuleConfEntry ::= SEQUENCE {
 | 
						||
prvtCESModuleIndex Integer32,
 | 
						||
prvtCESModuleLineType CESLineType,
 | 
						||
prvtCESModuleTxClock INTEGER,
 | 
						||
prvtCESModuleTxBackupClock INTEGER,
 | 
						||
prvtCESModuleConfig ConfigAction,
 | 
						||
prvtCESModuleIPAddress IpAddress,
 | 
						||
prvtCESModuleIPAddressMask IpAddress,
 | 
						||
prvtCESModuleGateway IpAddress,
 | 
						||
prvtCESModuleUpTime TimeStamp,
 | 
						||
prvtCESModuleMACAddress OCTET STRING,
 | 
						||
prvtCESModuleHardwareRevision OCTET STRING,
 | 
						||
prvtCESModuleFirmwareVersion OCTET STRING,
 | 
						||
prvtCESModuleClearCircuitStatistics INTEGER,
 | 
						||
prvtCESModuleLbit INTEGER,
 | 
						||
prvtCESModulePolicyLops INTEGER,
 | 
						||
prvtCESModulePolicyLbit INTEGER,
 | 
						||
prvtCESModulePolicyRbit INTEGER,
 | 
						||
prvtCESModulePolicyRd INTEGER,
 | 
						||
prvtCESModulePolicyIdlePattern Unsigned32,
 | 
						||
prvtCESModulePolicyIdleSignalling Unsigned32,
 | 
						||
prvtCESModulePolicyLopsEnter Integer32,
 | 
						||
prvtCESModulePolicyLopsExit Integer32,
 | 
						||
prvtCESModulePolicyuUnstrLbit INTEGER,
 | 
						||
prvtCESModulePolicyuStrReplace INTEGER,
 | 
						||
prvtCESModulePolicyuUnstrReplace INTEGER,
 | 
						||
prvtCESModulePolicyuUnstrLops INTEGER,
 | 
						||
prvtCESModuleServiceClock ServiceClock,
 | 
						||
prvtCESModulePolicyuUnstrReplacePattern Integer32
 | 
						||
}
 | 
						||
 | 
						||
prvtCESModuleIndex OBJECT-TYPE
 | 
						||
SYNTAX Integer32(1..65535)
 | 
						||
MAX-ACCESS accessible-for-notify
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Index of each CES module installed."
 | 
						||
::= { prvtCESModuleConfEntry 1 }
 | 
						||
 | 
						||
prvtCESModuleLineType OBJECT-TYPE
 | 
						||
SYNTAX CESLineType
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Line mode for the module."
 | 
						||
::= { prvtCESModuleConfEntry 2 }
 | 
						||
 | 
						||
prvtCESModuleTxClock OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
loopTiming(1),
 | 
						||
localTiming(2),
 | 
						||
throughTiming(3),
 | 
						||
adaptive (4),
 | 
						||
external-port (5),
 | 
						||
line (6),
 | 
						||
ptp(7)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Configures Transmit Source Clock for the module."
 | 
						||
::= { prvtCESModuleConfEntry 3 }
 | 
						||
 | 
						||
prvtCESModuleTxBackupClock OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable (1),
 | 
						||
disable (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Configures Backup Clock for the module."
 | 
						||
::= { prvtCESModuleConfEntry 4 }
 | 
						||
 | 
						||
prvtCESModuleConfig OBJECT-TYPE
 | 
						||
SYNTAX ConfigAction
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"When this object is set to applyConfiguration(2), the module is restarted
 | 
						||
and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object
 | 
						||
must be set to rejectConfiguration(3) to remove unapplied changes. If the object
 | 
						||
is set to restart(4), the module is restarted with applying the changes.
 | 
						||
This object always returns a value of noop(1) when get."
 | 
						||
::= { prvtCESModuleConfEntry 5 }
 | 
						||
 | 
						||
prvtCESModuleIPAddress OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The CES Module IP address after configuration is applied."
 | 
						||
::= { prvtCESModuleConfEntry 6 }
 | 
						||
 | 
						||
prvtCESModuleIPAddressMask OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The CES Module IP address mask after configuration is applied."
 | 
						||
::= { prvtCESModuleConfEntry 7 }
 | 
						||
 | 
						||
prvtCESModuleGateway OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" CES Module Gateway after configuration is applied."
 | 
						||
::= { prvtCESModuleConfEntry 8 }
 | 
						||
 | 
						||
prvtCESModuleUpTime OBJECT-TYPE
 | 
						||
SYNTAX TimeStamp
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"CES Up Time"
 | 
						||
::= { prvtCESModuleConfEntry 9 }
 | 
						||
 | 
						||
prvtCESModuleMACAddress OBJECT-TYPE
 | 
						||
SYNTAX OCTET STRING
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"CES MAC Address"
 | 
						||
::= { prvtCESModuleConfEntry 10 }
 | 
						||
 | 
						||
prvtCESModuleHardwareRevision OBJECT-TYPE
 | 
						||
SYNTAX OCTET STRING
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" CES Hardware revision"
 | 
						||
::= { prvtCESModuleConfEntry 11 }
 | 
						||
 | 
						||
prvtCESModuleFirmwareVersion OBJECT-TYPE
 | 
						||
SYNTAX OCTET STRING
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" CES Firmware revision"
 | 
						||
::= { prvtCESModuleConfEntry 12 }
 | 
						||
 | 
						||
prvtCESModuleClearCircuitStatistics OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none ( 0 ),
 | 
						||
clear ( 1 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Clear circuits statistics."
 | 
						||
::= { prvtCESModuleConfEntry 13 }
 | 
						||
 | 
						||
prvtCESModuleLbit OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable ( 1 ),
 | 
						||
disable ( 2 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Enable/disable L bit set upon AIS
 | 
						||
defect detection, in structure agnostic mode."
 | 
						||
::= { prvtCESModuleConfEntry 14 }
 | 
						||
 | 
						||
prvtCESModulePolicyLops OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
idle ( 0 ),
 | 
						||
all-one ( 1 ),
 | 
						||
channel-idle ( 2 ),
 | 
						||
none ( 3 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy lops. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 15 }
 | 
						||
 | 
						||
prvtCESModulePolicyLbit OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
idle ( 0 ),
 | 
						||
all-one ( 1 ),
 | 
						||
channel-idle ( 2 ),
 | 
						||
none ( 3 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy lbit. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 16 }
 | 
						||
 | 
						||
prvtCESModulePolicyRbit OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none ( 0 ),
 | 
						||
rai ( 1 ),
 | 
						||
channel-idle ( 2 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy rbit. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 17 }
 | 
						||
 | 
						||
prvtCESModulePolicyRd OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none ( 0 ),
 | 
						||
rai ( 1 ),
 | 
						||
channel-idle ( 2 )
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy rd. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 18 }
 | 
						||
 | 
						||
prvtCESModulePolicyIdlePattern OBJECT-TYPE
 | 
						||
SYNTAX Unsigned32 (0..255)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy idle pattern. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 19 }
 | 
						||
 | 
						||
prvtCESModulePolicyIdleSignalling OBJECT-TYPE
 | 
						||
SYNTAX Unsigned32 (1..15)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION "Controls policy idle signalling. Object does not require module to be restarted."
 | 
						||
::= { prvtCESModuleConfEntry 20 }
 | 
						||
 | 
						||
prvtCESModulePolicyLopsEnter OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..1023)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Controls the number of consecutive missed
 | 
						||
packets required to enter LOPS state.
 | 
						||
Object does not require module to be restarted."
 | 
						||
::= {prvtCESModuleConfEntry 21}
 | 
						||
 | 
						||
prvtCESModulePolicyLopsExit OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..1023)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Controls the number of consecutive missed
 | 
						||
packets required to exit LOPS state.
 | 
						||
Object does not require module to be restarted."
 | 
						||
::= {prvtCESModuleConfEntry 22}
 | 
						||
 | 
						||
prvtCESModulePolicyuUnstrLbit OBJECT-TYPE
 | 
						||
SYNTAX INTEGER{
 | 
						||
none(0),
 | 
						||
all-one(1)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If a packet is received with L bit set, and the payload is present (not suppressed),
 | 
						||
one of the following is sent to the TDM line, according to a globally configurable unstructured L-flag policy:
 | 
						||
The AIS pattern all-one
 | 
						||
The received payload as-is none"
 | 
						||
DEFVAL { all-one }
 | 
						||
::= {prvtCESModuleConfEntry 23}
 | 
						||
 | 
						||
prvtCESModulePolicyuStrReplace OBJECT-TYPE
 | 
						||
SYNTAX INTEGER{
 | 
						||
all-one(1),
 | 
						||
idle (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If a missing packet is detected, one of the following is sent to the TDM line,
 | 
						||
according to a globally configurable structured missing packet replacement policy:
 | 
						||
The AIS pattern all-one on the relevant timeslots
 | 
						||
The configured IDLE pattern"
 | 
						||
DEFVAL { all-one }
 | 
						||
::= {prvtCESModuleConfEntry 24}
 | 
						||
 | 
						||
prvtCESModulePolicyuUnstrReplace OBJECT-TYPE
 | 
						||
SYNTAX INTEGER{
 | 
						||
all-one(1),
 | 
						||
idle (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If a missing packet is detected, one of the following is sent to the TDM line,
 | 
						||
according to a globally configurable unstructured missing packet replacement policy:
 | 
						||
The AIS pattern all-one
 | 
						||
The configured IDLE pattern"
 | 
						||
DEFVAL { all-one }
 | 
						||
::= {prvtCESModuleConfEntry 25}
 | 
						||
 | 
						||
 | 
						||
prvtCESModulePolicyuUnstrLops OBJECT-TYPE
 | 
						||
SYNTAX INTEGER{
 | 
						||
none(0),
 | 
						||
all-one(1)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If a CES circuit enters the LOPS state, one of the following is sent to the TDM line,
 | 
						||
according to a globally configurable unstructured missing packet replacement policy:
 | 
						||
The AIS pattern all-one
 | 
						||
The contents of the jitter buffer - none"
 | 
						||
DEFVAL { all-one }
 | 
						||
::= {prvtCESModuleConfEntry 26}
 | 
						||
 | 
						||
prvtCESModuleServiceClock OBJECT-TYPE
 | 
						||
SYNTAX ServiceClock
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Clock mode for CES module"
 | 
						||
::= {prvtCESModuleConfEntry 27}  
 | 
						||
 | 
						||
 | 
						||
prvtCESModulePolicyuUnstrReplacePattern OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..255)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Unstructured packet replace policy pattern number"
 | 
						||
::= {prvtCESModuleConfEntry 28}  
 | 
						||
prvtCESDsx1AlarmTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESDsx1AlarmEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains object for configuring and displaying TDM ports TCA thresholds."
 | 
						||
::= { prvtCESObjects 4 }
 | 
						||
 | 
						||
prvtCESDsx1AlarmEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESDsx1AlarmEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESDsx1AlarmEntry"
 | 
						||
INDEX {prvtCESDsx1AlarmPort,prvtCESDsx1AlarmIndex}
 | 
						||
::= { prvtCESDsx1AlarmTable 1 }
 | 
						||
 | 
						||
PrvtCESDsx1AlarmEntry ::= SEQUENCE {
 | 
						||
prvtCESDsx1AlarmPort Integer32,
 | 
						||
prvtCESDsx1AlarmIndex Gauge32,
 | 
						||
prvtCESDsx1AlarmVariable OBJECT IDENTIFIER,
 | 
						||
prvtCESDsx1AlarmThreshold Integer32,
 | 
						||
prvtCESDsx1AlarmValue Integer32
 | 
						||
}
 | 
						||
 | 
						||
prvtCESDsx1AlarmPort OBJECT-TYPE
 | 
						||
SYNTAX Integer32(1..65535)
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" The DS1 port for which this alarm is configured. "
 | 
						||
::= { prvtCESDsx1AlarmEntry 1 }
 | 
						||
 | 
						||
prvtCESDsx1AlarmIndex OBJECT-TYPE
 | 
						||
SYNTAX Gauge32
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" An integer uniquely identifying an alarm entry."
 | 
						||
::= { prvtCESDsx1AlarmEntry 2 }
 | 
						||
 | 
						||
prvtCESDsx1AlarmVariable OBJECT-TYPE
 | 
						||
SYNTAX OBJECT IDENTIFIER
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The OID of the variable whose value is being monitored. Depending on the time interval,
 | 
						||
the error condition and the ifIndex of the TDM interface, this points to an object from an entry in
 | 
						||
dsx1CurrentTable or dsx1TotalTable."
 | 
						||
::= { prvtCESDsx1AlarmEntry 3 }
 | 
						||
 | 
						||
prvtCESDsx1AlarmThreshold OBJECT-TYPE
 | 
						||
SYNTAX Integer32
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The alarm condition threshold for this alarm entry. The alarm is triggered if the value of the
 | 
						||
object pointed by prvtCESDsx1AlarmVariable remains above this threshold for more than 3 seconds."
 | 
						||
::= { prvtCESDsx1AlarmEntry 4 }
 | 
						||
 | 
						||
prvtCESDsx1AlarmValue OBJECT-TYPE
 | 
						||
SYNTAX Integer32
 | 
						||
MAX-ACCESS accessible-for-notify
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes."
 | 
						||
::= { prvtCESDsx1AlarmEntry 5 }
 | 
						||
 | 
						||
prvtCESAlarmMonitor OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable(1),
 | 
						||
disable(2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"CES alarm monitor"
 | 
						||
DEFVAL { enable }
 | 
						||
::= { prvtCESObjects 5 }
 | 
						||
 | 
						||
prvtCESCICTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESCICEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains objects for configuring Clock Input Controller."
 | 
						||
::= { prvtCESObjects 6 }
 | 
						||
 | 
						||
prvtCESCICEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESCICEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESCICEntry"
 | 
						||
INDEX {prvtCESCICModuleId,prvtCESCICNumber}
 | 
						||
::= { prvtCESCICTable 1 }
 | 
						||
 | 
						||
PrvtCESCICEntry ::= SEQUENCE {
 | 
						||
prvtCESCICModuleId Integer32,
 | 
						||
prvtCESCICNumber Gauge32,
 | 
						||
prvtCESCICClockNumber Integer32,
 | 
						||
prvtCESCICMode 	 INTEGER,
 | 
						||
prvtCESCICTdmPort Integer32,
 | 
						||
prvtCESCICCircuit Integer32,
 | 
						||
prvtCESCICStatus INTEGER,
 | 
						||
prvtCESCICState INTEGER
 | 
						||
}
 | 
						||
 | 
						||
prvtCESCICModuleId OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..255)
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Slot of CES module installed."
 | 
						||
::= {prvtCESCICEntry 1}
 | 
						||
 | 
						||
prvtCESCICNumber OBJECT-TYPE
 | 
						||
SYNTAX Gauge32
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
" An integer uniquely identifying a Clock Input Controller."
 | 
						||
::= {prvtCESCICEntry 2}
 | 
						||
 | 
						||
prvtCESCICClockNumber OBJECT-TYPE
 | 
						||
SYNTAX Integer32
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This variable indicates the index of the clock
 | 
						||
the clock input controller belongs to"
 | 
						||
::= {prvtCESCICEntry 3}
 | 
						||
 | 
						||
prvtCESCICMode OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
freeRun (1),
 | 
						||
acquisition (2),
 | 
						||
normal (3),
 | 
						||
holdover (4),
 | 
						||
fastAcquisiton (5)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The mode of the clock input controller. Not
 | 
						||
all clock input controllers support all modes.
 | 
						||
The clock input controller status is 'locked'
 | 
						||
only if the clock input controller is in
 | 
						||
'normal' mode."
 | 
						||
::= {prvtCESCICEntry 4}
 | 
						||
 | 
						||
prvtCESCICTdmPort OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (0..4)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If the clock input controller recovers a clock
 | 
						||
from a port , this variable indicates the
 | 
						||
TDM Port. Otherwise, it must
 | 
						||
be set to zero."
 | 
						||
::= {prvtCESCICEntry 5}
 | 
						||
 | 
						||
prvtCESCICCircuit OBJECT-TYPE
 | 
						||
SYNTAX Integer32
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"If the clock input controller recovers a clock
 | 
						||
from a circuit, this variable indicates the
 | 
						||
circuit ID. Otherwise, it
 | 
						||
must be set to zero."
 | 
						||
::= {prvtCESCICEntry 6}
 | 
						||
 | 
						||
prvtCESCICStatus OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
locked (1),
 | 
						||
notlocked (2),
 | 
						||
sourceInputLost (3),
 | 
						||
sourceInputDegraded (4),
 | 
						||
sourceTraceLost (5),
 | 
						||
sourceTraceDegraded (6),
 | 
						||
sourceFreqOffsetFailure (7),
 | 
						||
recoveredClockDegraded (8),
 | 
						||
localReferenceFailure (9),
 | 
						||
remoteReferenceFailure (10)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The status of the input reference.Reference
 | 
						||
is ok when the status is 'locked'. Otherwise,
 | 
						||
the status is 'notLocked'. Alternatively, if an
 | 
						||
error was detected at the input, the status
 | 
						||
indicates this error."
 | 
						||
::= {prvtCESCICEntry 7}
 | 
						||
 | 
						||
prvtCESCICState OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
active (1),
 | 
						||
backup (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The state is set to 'active' if the input
 | 
						||
controller was selected by the clock to drive
 | 
						||
the clock output. At least one input out of
 | 
						||
the clock-input-controllers attached to a
 | 
						||
clock must be in an 'active' state at any given
 | 
						||
time"
 | 
						||
::= {prvtCESCICEntry 8}
 | 
						||
 | 
						||
--
 | 
						||
--
 | 
						||
--
 | 
						||
prvtCESCICMappTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESCICMappEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains clock configuration and status monitoring information."
 | 
						||
::= { prvtCESObjects 7 }
 | 
						||
 | 
						||
prvtCESCICMappEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESCICMappEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESCICMappEntry"
 | 
						||
INDEX {prvtCESCICMappModuleId,prvtCESCICMappClockNumber,prvtCESCICMappCICNumber}
 | 
						||
::= { prvtCESCICMappTable 1 }
 | 
						||
 | 
						||
PrvtCESCICMappEntry ::= SEQUENCE {
 | 
						||
prvtCESCICMappModuleId Integer32,
 | 
						||
prvtCESCICMappClockNumber Gauge32,
 | 
						||
prvtCESCICMappCICNumber Gauge32,
 | 
						||
prvtCESCICMappState INTEGER
 | 
						||
}
 | 
						||
 | 
						||
prvtCESCICMappModuleId OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..255)
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Slot of CES module installed."
 | 
						||
::= {prvtCESCICMappEntry 1}
 | 
						||
 | 
						||
prvtCESCICMappClockNumber OBJECT-TYPE
 | 
						||
SYNTAX Gauge32
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Index for the conceptual row
 | 
						||
identifying a clock within this
 | 
						||
mapping table"
 | 
						||
::= {prvtCESCICMappEntry 2}
 | 
						||
 | 
						||
prvtCESCICMappCICNumber OBJECT-TYPE
 | 
						||
SYNTAX Gauge32
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Index for the conceptual row
 | 
						||
identifying a clock input within
 | 
						||
this mapping table"
 | 
						||
::= {prvtCESCICMappEntry 3}
 | 
						||
 | 
						||
prvtCESCICMappState OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
active (1),
 | 
						||
backup (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The state is set to 'active' if the input
 | 
						||
controller was selected by the clock to drive
 | 
						||
the clock output. At least one input out of
 | 
						||
the clock-input-controllers attached to a
 | 
						||
clock must be in an 'active' state at any given
 | 
						||
time This value of this variable is
 | 
						||
equal to the prvtCESCICState
 | 
						||
variable in the CIC table"
 | 
						||
::= {prvtCESCICMappEntry 4}
 | 
						||
 | 
						||
prvtCESApsTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESApsEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains objects needed APS configuration"
 | 
						||
::= { prvtCESObjects 8 }
 | 
						||
 | 
						||
prvtCESApsEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESApsEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESApsEntry"
 | 
						||
INDEX {prvtCESModuleId}
 | 
						||
::= { prvtCESApsTable 1 }
 | 
						||
 | 
						||
PrvtCESApsEntry ::= SEQUENCE {
 | 
						||
	prvtCESApsModuleId Integer32,
 | 
						||
	prvtCESApsEnable INTEGER,
 | 
						||
	prvtCESApsActiveLine Integer32,
 | 
						||
	prvtSdBerThreshold Integer32,
 | 
						||
	prvtSfBerThreshold Integer32
 | 
						||
}
 | 
						||
 | 
						||
prvtCESApsModuleId OBJECT-TYPE
 | 
						||
SYNTAX Integer32
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"An integer uniquely identifying slot of the CES module installed"
 | 
						||
::= {prvtCESApsEntry 1}
 | 
						||
 | 
						||
prvtCESApsEnable OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
enable (1),
 | 
						||
disable (2)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Enable/Disable Automatic Protection Switching"
 | 
						||
DEFVAL { enable }
 | 
						||
::= {prvtCESApsEntry 2}
 | 
						||
 | 
						||
prvtCESApsActiveLine OBJECT-TYPE
 | 
						||
SYNTAX Integer32(1..2)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"APS active line"
 | 
						||
::= {prvtCESApsEntry 3}
 | 
						||
 | 
						||
prvtSdBerThreshold OBJECT-TYPE
 | 
						||
SYNTAX Integer32(5..9)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The Signal Degrade Bit Error Rate.
 | 
						||
The negated value of this number is used
 | 
						||
as the exponent of 10 for computing the
 | 
						||
threshold value for the Bit Error Rate
 | 
						||
(BER). For example, a value of 5 indicates
 | 
						||
a BER threshold of 10^-5."
 | 
						||
::= {prvtCESApsEntry 4}
 | 
						||
 | 
						||
prvtSfBerThreshold OBJECT-TYPE
 | 
						||
SYNTAX Integer32(3..5)
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The Signal Failure Bit Error Rate.
 | 
						||
The negated value of this number is used
 | 
						||
as the exponent of 10 for computing the
 | 
						||
threshold value for the Bit Error Rate
 | 
						||
(BER). For example, a value of 5 indicates
 | 
						||
a BER threshold of 10^-5."
 | 
						||
::= {prvtCESApsEntry 5}
 | 
						||
 | 
						||
prvtCESUpdateFirmwareTable OBJECT-TYPE
 | 
						||
SYNTAX SEQUENCE OF PrvtCESUpdateFirmwareEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This table contains object needed in update firmware of CES module"
 | 
						||
::= { prvtCESObjects 9 }
 | 
						||
 | 
						||
prvtCESUpdateFirmwareEntry OBJECT-TYPE
 | 
						||
SYNTAX PrvtCESUpdateFirmwareEntry
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESUpdateFirmwareEntry"
 | 
						||
INDEX {prvtCESModuleId}
 | 
						||
::= { prvtCESUpdateFirmwareTable 1 }
 | 
						||
 | 
						||
PrvtCESUpdateFirmwareEntry ::= SEQUENCE {
 | 
						||
prvtCESModuleId Integer32,
 | 
						||
prvtCESFirmwareImageName OCTET STRING,
 | 
						||
prvtCESUpdateAction INTEGER,
 | 
						||
prvtCESUpdateStatus INTEGER,
 | 
						||
prvtCESTFTPServer IpAddress
 | 
						||
}
 | 
						||
 | 
						||
prvtCESModuleId OBJECT-TYPE
 | 
						||
SYNTAX Integer32 (1..32000)
 | 
						||
MAX-ACCESS not-accessible
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"An integer uniquely identifying slot of the CES module installed"
 | 
						||
::= {prvtCESUpdateFirmwareEntry 1}
 | 
						||
 | 
						||
prvtCESFirmwareImageName OBJECT-TYPE
 | 
						||
SYNTAX OCTET STRING
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Name of the firmware image file "
 | 
						||
::= {prvtCESUpdateFirmwareEntry 2}
 | 
						||
 | 
						||
prvtCESUpdateAction OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
none	(1),
 | 
						||
update (2),
 | 
						||
updateThroughUART (3)
 | 
						||
}
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"Update CES firmware "
 | 
						||
::= {prvtCESUpdateFirmwareEntry 3}
 | 
						||
 | 
						||
prvtCESUpdateStatus OBJECT-TYPE
 | 
						||
SYNTAX INTEGER {
 | 
						||
updateStatusUnknown (1),
 | 
						||
updateSuccess (2),
 | 
						||
updateInProgress (3),
 | 
						||
updateFailed (4)
 | 
						||
 | 
						||
}
 | 
						||
MAX-ACCESS read-only
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The status of the last update procedure, if any. This
 | 
						||
	object will have a value of updateStatusUnknown(2) if no
 | 
						||
	update process has been performed."
 | 
						||
::= {prvtCESUpdateFirmwareEntry 4}
 | 
						||
 | 
						||
prvtCESTFTPServer OBJECT-TYPE
 | 
						||
SYNTAX IpAddress
 | 
						||
MAX-ACCESS read-write
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"IP Address of Tftp Server"
 | 
						||
::= {prvtCESUpdateFirmwareEntry 5}
 | 
						||
 | 
						||
prvtCESDsx1Alarm NOTIFICATION-TYPE
 | 
						||
OBJECTS {prvtCESDsx1AlarmVariable,prvtCESDsx1AlarmThreshold,prvtCESDsx1AlarmValue}
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"This notification is sent when the value of a TDM port error condition statistic has exceeded the
 | 
						||
configured threshold."
 | 
						||
::= {prvtCESNotifications 1}
 | 
						||
 | 
						||
prvtCESModuleAvailable NOTIFICATION-TYPE
 | 
						||
OBJECTS {prvtCESModuleIndex}
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESModuleAvailable trap"
 | 
						||
::= {prvtCESNotifications 2}
 | 
						||
 | 
						||
prvtCESModuleUnAvailableDueExtract NOTIFICATION-TYPE
 | 
						||
OBJECTS {prvtCESModuleIndex}
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESModuleUnAvailableDueExtract trap."
 | 
						||
::= {prvtCESNotifications 3}
 | 
						||
 | 
						||
prvtCESModuleUnAvailableDueReload NOTIFICATION-TYPE
 | 
						||
OBJECTS {prvtCESModuleIndex}
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"prvtCESModuleUnAvailableDueReload trap"
 | 
						||
::= {prvtCESNotifications 4}
 | 
						||
--
 | 
						||
-- Conformance Information
 | 
						||
--
 | 
						||
 | 
						||
prvtCESDsx1Compliances OBJECT IDENTIFIER ::= { prvtCESConformance 1 }
 | 
						||
prvtCESDsx1Groups OBJECT IDENTIFIER ::= { prvtCESConformance 2 }
 | 
						||
 | 
						||
-- compliance statements
 | 
						||
prvtCESDsx1Compliance MODULE-COMPLIANCE
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The compliance statement for management of TDM ports."
 | 
						||
MODULE -- this module
 | 
						||
MANDATORY-GROUPS {
 | 
						||
prvtCESDsx1NotificationsGroup,
 | 
						||
prvtCESDsx1ROGroup
 | 
						||
}
 | 
						||
::= { prvtCESDsx1Compliances 1 }
 | 
						||
 | 
						||
prvtCESDsx1NotificationsGroup NOTIFICATION-GROUP
 | 
						||
NOTIFICATIONS { prvtCESDsx1Alarm }
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The group of supported notifications."
 | 
						||
::= { prvtCESDsx1Groups 1 }
 | 
						||
prvtCESDsx1ROGroup OBJECT-GROUP
 | 
						||
OBJECTS { prvtCESE1Impedance,
 | 
						||
prvtCEST1GainLimit,
 | 
						||
prvtCESModuleLineType,
 | 
						||
prvtCESModuleTxClock,
 | 
						||
prvtCESModuleConfig,
 | 
						||
prvtCESModuleIPAddress,
 | 
						||
prvtCESModuleIPAddressMask,
 | 
						||
prvtCESModuleGateway,
 | 
						||
prvtCESDsx1AlarmThreshold
 | 
						||
}
 | 
						||
STATUS current
 | 
						||
DESCRIPTION
 | 
						||
"The group of objects with MAX-ACCESS read-write supported with read-only access for the first release."
 | 
						||
::= { prvtCESDsx1Groups 2 }
 | 
						||
 | 
						||
END
 |