mibs/MIBS/telco-systems/binos/PRVT-CES-MIB
2023-12-05 12:25:34 +01:00

1383 lines
33 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

-- *********************************************************************
-- *********************************************************************
-- ** Filename: PRVT-CES-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-CES-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
IpAddress,
Gauge32,
Integer32,
Unsigned32,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
TimeStamp
FROM SNMPv2-TC
dsx1ConfigEntry
FROM DS1-MIB
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
OBJECT-GROUP
FROM SNMPv2-CONF
switch
FROM PRVT-SWITCH-MIB;
prvtCESMib MODULE-IDENTITY
LAST-UPDATED "200905180000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"This module includes configuration parameters for DS1 modules not included in
DS1-MIB."
-- revision history
REVISION "200905180000Z"
DESCRIPTION
"OC3 Alarm Enhacements"
REVISION "200905140000Z"
DESCRIPTION
"Add prvtCESApsTable"
REVISION "200905050000Z"
DESCRIPTION
"Add prvtCESUpdateFirmwareTable"
REVISION "200903190000Z"
DESCRIPTION
"Add new objects prvtCESServiceClock, prvtCESModuleServiceClock"
REVISION "200902250000Z"
DESCRIPTION
"Add prvtCESCICTable, prvtCESCICMappTable,
prvtCESModulePolicyLopsEnter, prvtCESModulePolicyLopsExit "
REVISION "200902160000Z"
DESCRIPTION
"Modified values for objects
prvtCESModulePolicyLops, prvtCESModulePolicyRbit,
prvtCESModulePolicyRd"
REVISION "200806190000Z"
DESCRIPTION
"Added new objects
prvtCESClearPortStatistics, prvtCESModuleClearCircuitStatistics,
prvtCESModuleLbit, prvtCESModulePolicyLops,
prvtCESModulePolicyLbit, prvtCESModulePolicyRbit,
prvtCESModulePolicyRd, prvtCESModulePolicyIdlePattern,
prvtCESModulePolicyIdleSignalling"
REVISION "200603070000Z"
DESCRIPTION
"Added an additional port index to the alarm table."
REVISION "200602230000Z"
DESCRIPTION
"Added the TCA alarms table objects and the TCA alarm trap."
REVISION "200503110000Z"
DESCRIPTION
"Initial version."
::= { switch 111 }
--
-- Variable Type definitions
--
ConfigAction ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value is used to specify what is to be done with unapplied CES module configuration."
SYNTAX INTEGER {
noop(1),
applyConfiguration(2),
rejectConfiguration(3),
restart(4)
}
E1Impedance ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value is used to configure E1 line type termination impedance."
SYNTAX INTEGER {
notApplicable(0),
e1-75ohm(1),
e1-75hrl(2),
e1-120ohm(3),
e1-120hrl(4)
}
T1LongCableLength ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value is used to configure T1 long cable length."
SYNTAX INTEGER {
notApplicable (1),
neg75dB (2),
neg15dB (3),
neg225dB (4),
zerodB (5)
}
T1GainLimit ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value is used to configure T1 type Tx or Rx gain limit."
SYNTAX INTEGER {
notApplicable(0),
none(1),
gain30(2),
gain36(3)
}
CESLineType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value is used to configure the line mode common for all TDM ports of the module."
SYNTAX INTEGER {
e1(1),
t1(2),
e1-sdh(3),
t1-sdh(4),
t1-sonet(5)
}
ServiceClock ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This values are used to configure transmit clock as one of this modes."
SYNTAX INTEGER{
notAplicable(0),
loopTiming (1),
localTiming (2),
adaptive (3),
differntial (4)
}
prvtCESNotifications OBJECT IDENTIFIER ::= { prvtCESMib 0 }
prvtCESObjects OBJECT IDENTIFIER ::= { prvtCESMib 1 }
prvtCESConformance OBJECT IDENTIFIER ::= { prvtCESMib 2 }
--
-- ces objects
--
prvtCESDsx1ExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESDsx1ExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for configuring DS1 interfaces, not supported in dsx1ConfigTable."
::= { prvtCESObjects 1 }
prvtCESDsx1ExtEntry OBJECT-TYPE
SYNTAX PrvtCESDsx1ExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESDsx1ExtEntry"
AUGMENTS { dsx1ConfigEntry }
::= { prvtCESDsx1ExtTable 1 }
PrvtCESDsx1ExtEntry ::= SEQUENCE {
prvtCESE1Impedance E1Impedance,
prvtCEST1GainLimit T1GainLimit,
prvtCESPortShutdown INTEGER,
prvtCESPortLineType INTEGER,
prvtCEST1LongCableLength T1LongCableLength,
prvtCESPortOperStatus INTEGER,
prvtCESClearPortStatistics INTEGER,
prvtCESServiceClock ServiceClock
}
prvtCESE1Impedance OBJECT-TYPE
SYNTAX E1Impedance
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures temination impedance for TDM ports if the line type is E1."
::= { prvtCESDsx1ExtEntry 1 }
prvtCEST1GainLimit OBJECT-TYPE
SYNTAX T1GainLimit
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures Tx or Rx gain limit for TDM ports if the line type is T1."
::= { prvtCESDsx1ExtEntry 2 }
prvtCESPortShutdown OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shutdown TDM port."
::= { prvtCESDsx1ExtEntry 3 }
prvtCESPortLineType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
dsx1ESF(2),
dsx1D4(3),
dsx1E1(4),
dsx1E1CRC(5),
dsx1E1MF(6),
dsx1E1CRCMF(7),
dsx1Unframed(8),
dsx1E1Unframed(9),
dsx1DS2M12(10),
dsx1E2(11),
dsx1E1Q50(12),
dsx1E1Q50CRC(13),
dsx1SFCAS(14),
dsx1ESFCAS(15),
notApplicable(16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Additional line types. For reference see object dsx1LineType"
::= { prvtCESDsx1ExtEntry 4 }
prvtCEST1LongCableLength OBJECT-TYPE
SYNTAX T1LongCableLength
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Long cable length options for T1 mode."
::= { prvtCESDsx1ExtEntry 5 }
prvtCESPortOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
testing(3),
unknown(4),
dormant(5),
notPresent(6),
lowerlayerDown(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TDM link state."
::= { prvtCESDsx1ExtEntry 6 }
prvtCESClearPortStatistics OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
clear ( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clear port statistics."
::= { prvtCESDsx1ExtEntry 7 }
prvtCESServiceClock OBJECT-TYPE
SYNTAX ServiceClock
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Service Clock available only for DS1 interface."
::= { prvtCESDsx1ExtEntry 8 }
prvtCESUnappTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESUnappEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table displays CES module configuration which will take effect
after prvtCESModuleConf is set to applyConfiguration(2)."
::= { prvtCESObjects 3 }
prvtCESUnappEntry OBJECT-TYPE
SYNTAX PrvtCESUnappEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESUnappEntry"
AUGMENTS { dsx1ConfigEntry }
::= { prvtCESUnappTable 1 }
PrvtCESUnappEntry ::= SEQUENCE {
prvtCESUnappLineType INTEGER,
prvtCESUnappLineCoding INTEGER,
prvtCESUnappLoopbackConfig INTEGER,
prvtCESUnappSignalMode INTEGER,
prvtCESUnappTransmitClockSource INTEGER,
prvtCESUnappTransmitClockBackup INTEGER,
prvtCESUnappLineLength Integer32,
prvtCESUnappLineMode INTEGER,
prvtCESUnappLineBuildOut INTEGER,
prvtCESUnappE1Impedance E1Impedance,
prvtCESUnappT1GainLimit T1GainLimit,
prvtCESUnappIPAddress IpAddress,
prvtCESUnappIPAddressMask IpAddress,
prvtCESUnappGateway IpAddress
}
prvtCESUnappLineType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
dsx1ESF(2),
dsx1D4(3),
dsx1E1(4),
dsx1E1CRC(5),
dsx1E1MF(6),
dsx1E1CRCMF(7),
dsx1Unframed(8),
dsx1E1Unframed(9),
dsx1DS2M12(10),
dsx1E2(11),
dsx1E1Q50(12),
dsx1E1Q50CRC(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LineType before configuration is applied."
::= { prvtCESUnappEntry 1 }
prvtCESUnappLineCoding OBJECT-TYPE
SYNTAX INTEGER {
dsx1JBZS (1),
dsx1B8ZS (2),
dsx1HDB3 (3),
dsx1ZBTSI (4),
dsx1AMI (5),
other(6),
dsx1B6ZS(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LineCoding before configuration is applied."
::= { prvtCESUnappEntry 2 }
prvtCESUnappLoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
dsx1NoLoop(1),
dsx1PayloadLoop(2),
dsx1LineLoop(3),
dsx1OtherLoop(4),
dsx1InwardLoop(5),
dsx1DualLoop(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LoopbackConfig before configuration is applied."
::= { prvtCESUnappEntry 3 }
prvtCESUnappSignalMode OBJECT-TYPE
SYNTAX INTEGER {
none (1),
robbedBit (2),
bitOriented (3),
messageOriented (4),
other (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1SignalMode before configuration is applied."
::= { prvtCESUnappEntry 4 }
prvtCESUnappTransmitClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
adaptive (4),
external-port (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1TransmitClockSource before configuration is applied."
::= { prvtCESUnappEntry 5 }
prvtCESUnappTransmitClockBackup OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1TransmitClockBackup before configuration is applied."
::= { prvtCESUnappEntry 6 }
prvtCESUnappLineLength OBJECT-TYPE
SYNTAX Integer32 (0..64000)
UNITS "meters"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LineLength before configuration is applied."
::= { prvtCESUnappEntry 7 }
prvtCESUnappLineMode OBJECT-TYPE
SYNTAX INTEGER {
csu(1),
dsu(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LineMode before configuration is applied."
::= { prvtCESUnappEntry 8 }
prvtCESUnappLineBuildOut OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
neg75dB (2),
neg15dB (3),
neg225dB (4),
zerodB (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of dsx1LineBuildOut before configuration is applied."
::= { prvtCESUnappEntry 9 }
prvtCESUnappE1Impedance OBJECT-TYPE
SYNTAX E1Impedance
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prvtCESE1Impedance before configuration is applied."
::= { prvtCESUnappEntry 10 }
prvtCESUnappT1GainLimit OBJECT-TYPE
SYNTAX T1GainLimit
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of prvtCEST1GainLimit before configuration is applied."
::= { prvtCESUnappEntry 11 }
prvtCESUnappIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CES Module IP address before configuration is applied."
::= { prvtCESUnappEntry 12 }
prvtCESUnappIPAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CES Module IP address mask before configuration is applied."
::= { prvtCESUnappEntry 13 }
prvtCESUnappGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CES Module Gateway before configuration is applied."
::= { prvtCESUnappEntry 14 }
prvtCESModuleConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESModuleConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for configuring options that are applied to the entire module."
::= { prvtCESObjects 2 }
prvtCESModuleConfEntry OBJECT-TYPE
SYNTAX PrvtCESModuleConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESModuleConfEntry"
INDEX {prvtCESModuleIndex}
::= { prvtCESModuleConfTable 1 }
PrvtCESModuleConfEntry ::= SEQUENCE {
prvtCESModuleIndex Integer32,
prvtCESModuleLineType CESLineType,
prvtCESModuleTxClock INTEGER,
prvtCESModuleTxBackupClock INTEGER,
prvtCESModuleConfig ConfigAction,
prvtCESModuleIPAddress IpAddress,
prvtCESModuleIPAddressMask IpAddress,
prvtCESModuleGateway IpAddress,
prvtCESModuleUpTime TimeStamp,
prvtCESModuleMACAddress OCTET STRING,
prvtCESModuleHardwareRevision OCTET STRING,
prvtCESModuleFirmwareVersion OCTET STRING,
prvtCESModuleClearCircuitStatistics INTEGER,
prvtCESModuleLbit INTEGER,
prvtCESModulePolicyLops INTEGER,
prvtCESModulePolicyLbit INTEGER,
prvtCESModulePolicyRbit INTEGER,
prvtCESModulePolicyRd INTEGER,
prvtCESModulePolicyIdlePattern Unsigned32,
prvtCESModulePolicyIdleSignalling Unsigned32,
prvtCESModulePolicyLopsEnter Integer32,
prvtCESModulePolicyLopsExit Integer32,
prvtCESModulePolicyuUnstrLbit INTEGER,
prvtCESModulePolicyuStrReplace INTEGER,
prvtCESModulePolicyuUnstrReplace INTEGER,
prvtCESModulePolicyuUnstrLops INTEGER,
prvtCESModuleServiceClock ServiceClock,
prvtCESModulePolicyuUnstrReplacePattern Integer32
}
prvtCESModuleIndex OBJECT-TYPE
SYNTAX Integer32(1..65535)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Index of each CES module installed."
::= { prvtCESModuleConfEntry 1 }
prvtCESModuleLineType OBJECT-TYPE
SYNTAX CESLineType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Line mode for the module."
::= { prvtCESModuleConfEntry 2 }
prvtCESModuleTxClock OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
adaptive (4),
external-port (5),
line (6),
ptp(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures Transmit Source Clock for the module."
::= { prvtCESModuleConfEntry 3 }
prvtCESModuleTxBackupClock OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures Backup Clock for the module."
::= { prvtCESModuleConfEntry 4 }
prvtCESModuleConfig OBJECT-TYPE
SYNTAX ConfigAction
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this object is set to applyConfiguration(2), the module is restarted
and the changes in dsx1ConfigTable or prvtCESConfTable are applied. The object
must be set to rejectConfiguration(3) to remove unapplied changes. If the object
is set to restart(4), the module is restarted with applying the changes.
This object always returns a value of noop(1) when get."
::= { prvtCESModuleConfEntry 5 }
prvtCESModuleIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CES Module IP address after configuration is applied."
::= { prvtCESModuleConfEntry 6 }
prvtCESModuleIPAddressMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The CES Module IP address mask after configuration is applied."
::= { prvtCESModuleConfEntry 7 }
prvtCESModuleGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" CES Module Gateway after configuration is applied."
::= { prvtCESModuleConfEntry 8 }
prvtCESModuleUpTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CES Up Time"
::= { prvtCESModuleConfEntry 9 }
prvtCESModuleMACAddress OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CES MAC Address"
::= { prvtCESModuleConfEntry 10 }
prvtCESModuleHardwareRevision OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" CES Hardware revision"
::= { prvtCESModuleConfEntry 11 }
prvtCESModuleFirmwareVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" CES Firmware revision"
::= { prvtCESModuleConfEntry 12 }
prvtCESModuleClearCircuitStatistics OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
clear ( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Clear circuits statistics."
::= { prvtCESModuleConfEntry 13 }
prvtCESModuleLbit OBJECT-TYPE
SYNTAX INTEGER {
enable ( 1 ),
disable ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable L bit set upon AIS
defect detection, in structure agnostic mode."
::= { prvtCESModuleConfEntry 14 }
prvtCESModulePolicyLops OBJECT-TYPE
SYNTAX INTEGER {
idle ( 0 ),
all-one ( 1 ),
channel-idle ( 2 ),
none ( 3 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy lops. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 15 }
prvtCESModulePolicyLbit OBJECT-TYPE
SYNTAX INTEGER {
idle ( 0 ),
all-one ( 1 ),
channel-idle ( 2 ),
none ( 3 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy lbit. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 16 }
prvtCESModulePolicyRbit OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
rai ( 1 ),
channel-idle ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy rbit. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 17 }
prvtCESModulePolicyRd OBJECT-TYPE
SYNTAX INTEGER {
none ( 0 ),
rai ( 1 ),
channel-idle ( 2 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy rd. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 18 }
prvtCESModulePolicyIdlePattern OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy idle pattern. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 19 }
prvtCESModulePolicyIdleSignalling OBJECT-TYPE
SYNTAX Unsigned32 (1..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Controls policy idle signalling. Object does not require module to be restarted."
::= { prvtCESModuleConfEntry 20 }
prvtCESModulePolicyLopsEnter OBJECT-TYPE
SYNTAX Integer32 (1..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the number of consecutive missed
packets required to enter LOPS state.
Object does not require module to be restarted."
::= {prvtCESModuleConfEntry 21}
prvtCESModulePolicyLopsExit OBJECT-TYPE
SYNTAX Integer32 (1..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the number of consecutive missed
packets required to exit LOPS state.
Object does not require module to be restarted."
::= {prvtCESModuleConfEntry 22}
prvtCESModulePolicyuUnstrLbit OBJECT-TYPE
SYNTAX INTEGER{
none(0),
all-one(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a packet is received with L bit set, and the payload is present (not suppressed),
one of the following is sent to the TDM line, according to a globally configurable unstructured L-flag policy:
The AIS pattern all-one
The received payload as-is none"
DEFVAL { all-one }
::= {prvtCESModuleConfEntry 23}
prvtCESModulePolicyuStrReplace OBJECT-TYPE
SYNTAX INTEGER{
all-one(1),
idle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a missing packet is detected, one of the following is sent to the TDM line,
according to a globally configurable structured missing packet replacement policy:
The AIS pattern all-one on the relevant timeslots
The configured IDLE pattern"
DEFVAL { all-one }
::= {prvtCESModuleConfEntry 24}
prvtCESModulePolicyuUnstrReplace OBJECT-TYPE
SYNTAX INTEGER{
all-one(1),
idle (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a missing packet is detected, one of the following is sent to the TDM line,
according to a globally configurable unstructured missing packet replacement policy:
The AIS pattern all-one
The configured IDLE pattern"
DEFVAL { all-one }
::= {prvtCESModuleConfEntry 25}
prvtCESModulePolicyuUnstrLops OBJECT-TYPE
SYNTAX INTEGER{
none(0),
all-one(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If a CES circuit enters the LOPS state, one of the following is sent to the TDM line,
according to a globally configurable unstructured missing packet replacement policy:
The AIS pattern all-one
The contents of the jitter buffer - none"
DEFVAL { all-one }
::= {prvtCESModuleConfEntry 26}
prvtCESModuleServiceClock OBJECT-TYPE
SYNTAX ServiceClock
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode for CES module"
::= {prvtCESModuleConfEntry 27}
prvtCESModulePolicyuUnstrReplacePattern OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Unstructured packet replace policy pattern number"
::= {prvtCESModuleConfEntry 28}
prvtCESDsx1AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESDsx1AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object for configuring and displaying TDM ports TCA thresholds."
::= { prvtCESObjects 4 }
prvtCESDsx1AlarmEntry OBJECT-TYPE
SYNTAX PrvtCESDsx1AlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESDsx1AlarmEntry"
INDEX {prvtCESDsx1AlarmPort,prvtCESDsx1AlarmIndex}
::= { prvtCESDsx1AlarmTable 1 }
PrvtCESDsx1AlarmEntry ::= SEQUENCE {
prvtCESDsx1AlarmPort Integer32,
prvtCESDsx1AlarmIndex Gauge32,
prvtCESDsx1AlarmVariable OBJECT IDENTIFIER,
prvtCESDsx1AlarmThreshold Integer32,
prvtCESDsx1AlarmValue Integer32
}
prvtCESDsx1AlarmPort OBJECT-TYPE
SYNTAX Integer32(1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The DS1 port for which this alarm is configured. "
::= { prvtCESDsx1AlarmEntry 1 }
prvtCESDsx1AlarmIndex OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An integer uniquely identifying an alarm entry."
::= { prvtCESDsx1AlarmEntry 2 }
prvtCESDsx1AlarmVariable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OID of the variable whose value is being monitored. Depending on the time interval,
the error condition and the ifIndex of the TDM interface, this points to an object from an entry in
dsx1CurrentTable or dsx1TotalTable."
::= { prvtCESDsx1AlarmEntry 3 }
prvtCESDsx1AlarmThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The alarm condition threshold for this alarm entry. The alarm is triggered if the value of the
object pointed by prvtCESDsx1AlarmVariable remains above this threshold for more than 3 seconds."
::= { prvtCESDsx1AlarmEntry 4 }
prvtCESDsx1AlarmValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The value of the object pointed to by prvtCESDsx1AlarmVariable, present for notification purposes."
::= { prvtCESDsx1AlarmEntry 5 }
prvtCESAlarmMonitor OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CES alarm monitor"
DEFVAL { enable }
::= { prvtCESObjects 5 }
prvtCESCICTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESCICEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects for configuring Clock Input Controller."
::= { prvtCESObjects 6 }
prvtCESCICEntry OBJECT-TYPE
SYNTAX PrvtCESCICEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESCICEntry"
INDEX {prvtCESCICModuleId,prvtCESCICNumber}
::= { prvtCESCICTable 1 }
PrvtCESCICEntry ::= SEQUENCE {
prvtCESCICModuleId Integer32,
prvtCESCICNumber Gauge32,
prvtCESCICClockNumber Integer32,
prvtCESCICMode INTEGER,
prvtCESCICTdmPort Integer32,
prvtCESCICCircuit Integer32,
prvtCESCICStatus INTEGER,
prvtCESCICState INTEGER
}
prvtCESCICModuleId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Slot of CES module installed."
::= {prvtCESCICEntry 1}
prvtCESCICNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An integer uniquely identifying a Clock Input Controller."
::= {prvtCESCICEntry 2}
prvtCESCICClockNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the index of the clock
the clock input controller belongs to"
::= {prvtCESCICEntry 3}
prvtCESCICMode OBJECT-TYPE
SYNTAX INTEGER {
freeRun (1),
acquisition (2),
normal (3),
holdover (4),
fastAcquisiton (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode of the clock input controller. Not
all clock input controllers support all modes.
The clock input controller status is 'locked'
only if the clock input controller is in
'normal' mode."
::= {prvtCESCICEntry 4}
prvtCESCICTdmPort OBJECT-TYPE
SYNTAX Integer32 (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the clock input controller recovers a clock
from a port , this variable indicates the
TDM Port. Otherwise, it must
be set to zero."
::= {prvtCESCICEntry 5}
prvtCESCICCircuit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the clock input controller recovers a clock
from a circuit, this variable indicates the
circuit ID. Otherwise, it
must be set to zero."
::= {prvtCESCICEntry 6}
prvtCESCICStatus OBJECT-TYPE
SYNTAX INTEGER {
locked (1),
notlocked (2),
sourceInputLost (3),
sourceInputDegraded (4),
sourceTraceLost (5),
sourceTraceDegraded (6),
sourceFreqOffsetFailure (7),
recoveredClockDegraded (8),
localReferenceFailure (9),
remoteReferenceFailure (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the input reference.Reference
is ok when the status is 'locked'. Otherwise,
the status is 'notLocked'. Alternatively, if an
error was detected at the input, the status
indicates this error."
::= {prvtCESCICEntry 7}
prvtCESCICState OBJECT-TYPE
SYNTAX INTEGER {
active (1),
backup (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state is set to 'active' if the input
controller was selected by the clock to drive
the clock output. At least one input out of
the clock-input-controllers attached to a
clock must be in an 'active' state at any given
time"
::= {prvtCESCICEntry 8}
--
--
--
prvtCESCICMappTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESCICMappEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains clock configuration and status monitoring information."
::= { prvtCESObjects 7 }
prvtCESCICMappEntry OBJECT-TYPE
SYNTAX PrvtCESCICMappEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESCICMappEntry"
INDEX {prvtCESCICMappModuleId,prvtCESCICMappClockNumber,prvtCESCICMappCICNumber}
::= { prvtCESCICMappTable 1 }
PrvtCESCICMappEntry ::= SEQUENCE {
prvtCESCICMappModuleId Integer32,
prvtCESCICMappClockNumber Gauge32,
prvtCESCICMappCICNumber Gauge32,
prvtCESCICMappState INTEGER
}
prvtCESCICMappModuleId OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot of CES module installed."
::= {prvtCESCICMappEntry 1}
prvtCESCICMappClockNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for the conceptual row
identifying a clock within this
mapping table"
::= {prvtCESCICMappEntry 2}
prvtCESCICMappCICNumber OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index for the conceptual row
identifying a clock input within
this mapping table"
::= {prvtCESCICMappEntry 3}
prvtCESCICMappState OBJECT-TYPE
SYNTAX INTEGER {
active (1),
backup (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state is set to 'active' if the input
controller was selected by the clock to drive
the clock output. At least one input out of
the clock-input-controllers attached to a
clock must be in an 'active' state at any given
time This value of this variable is
equal to the prvtCESCICState
variable in the CIC table"
::= {prvtCESCICMappEntry 4}
prvtCESApsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESApsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains objects needed APS configuration"
::= { prvtCESObjects 8 }
prvtCESApsEntry OBJECT-TYPE
SYNTAX PrvtCESApsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESApsEntry"
INDEX {prvtCESModuleId}
::= { prvtCESApsTable 1 }
PrvtCESApsEntry ::= SEQUENCE {
prvtCESApsModuleId Integer32,
prvtCESApsEnable INTEGER,
prvtCESApsActiveLine Integer32,
prvtSdBerThreshold Integer32,
prvtSfBerThreshold Integer32
}
prvtCESApsModuleId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer uniquely identifying slot of the CES module installed"
::= {prvtCESApsEntry 1}
prvtCESApsEnable OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Automatic Protection Switching"
DEFVAL { enable }
::= {prvtCESApsEntry 2}
prvtCESApsActiveLine OBJECT-TYPE
SYNTAX Integer32(1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"APS active line"
::= {prvtCESApsEntry 3}
prvtSdBerThreshold OBJECT-TYPE
SYNTAX Integer32(5..9)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signal Degrade Bit Error Rate.
The negated value of this number is used
as the exponent of 10 for computing the
threshold value for the Bit Error Rate
(BER). For example, a value of 5 indicates
a BER threshold of 10^-5."
::= {prvtCESApsEntry 4}
prvtSfBerThreshold OBJECT-TYPE
SYNTAX Integer32(3..5)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Signal Failure Bit Error Rate.
The negated value of this number is used
as the exponent of 10 for computing the
threshold value for the Bit Error Rate
(BER). For example, a value of 5 indicates
a BER threshold of 10^-5."
::= {prvtCESApsEntry 5}
prvtCESUpdateFirmwareTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtCESUpdateFirmwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains object needed in update firmware of CES module"
::= { prvtCESObjects 9 }
prvtCESUpdateFirmwareEntry OBJECT-TYPE
SYNTAX PrvtCESUpdateFirmwareEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtCESUpdateFirmwareEntry"
INDEX {prvtCESModuleId}
::= { prvtCESUpdateFirmwareTable 1 }
PrvtCESUpdateFirmwareEntry ::= SEQUENCE {
prvtCESModuleId Integer32,
prvtCESFirmwareImageName OCTET STRING,
prvtCESUpdateAction INTEGER,
prvtCESUpdateStatus INTEGER,
prvtCESTFTPServer IpAddress
}
prvtCESModuleId OBJECT-TYPE
SYNTAX Integer32 (1..32000)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An integer uniquely identifying slot of the CES module installed"
::= {prvtCESUpdateFirmwareEntry 1}
prvtCESFirmwareImageName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name of the firmware image file "
::= {prvtCESUpdateFirmwareEntry 2}
prvtCESUpdateAction OBJECT-TYPE
SYNTAX INTEGER {
none (1),
update (2),
updateThroughUART (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Update CES firmware "
::= {prvtCESUpdateFirmwareEntry 3}
prvtCESUpdateStatus OBJECT-TYPE
SYNTAX INTEGER {
updateStatusUnknown (1),
updateSuccess (2),
updateInProgress (3),
updateFailed (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the last update procedure, if any. This
object will have a value of updateStatusUnknown(2) if no
update process has been performed."
::= {prvtCESUpdateFirmwareEntry 4}
prvtCESTFTPServer OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP Address of Tftp Server"
::= {prvtCESUpdateFirmwareEntry 5}
prvtCESDsx1Alarm NOTIFICATION-TYPE
OBJECTS {prvtCESDsx1AlarmVariable,prvtCESDsx1AlarmThreshold,prvtCESDsx1AlarmValue}
STATUS current
DESCRIPTION
"This notification is sent when the value of a TDM port error condition statistic has exceeded the
configured threshold."
::= {prvtCESNotifications 1}
prvtCESModuleAvailable NOTIFICATION-TYPE
OBJECTS {prvtCESModuleIndex}
STATUS current
DESCRIPTION
"prvtCESModuleAvailable trap"
::= {prvtCESNotifications 2}
prvtCESModuleUnAvailableDueExtract NOTIFICATION-TYPE
OBJECTS {prvtCESModuleIndex}
STATUS current
DESCRIPTION
"prvtCESModuleUnAvailableDueExtract trap."
::= {prvtCESNotifications 3}
prvtCESModuleUnAvailableDueReload NOTIFICATION-TYPE
OBJECTS {prvtCESModuleIndex}
STATUS current
DESCRIPTION
"prvtCESModuleUnAvailableDueReload trap"
::= {prvtCESNotifications 4}
--
-- Conformance Information
--
prvtCESDsx1Compliances OBJECT IDENTIFIER ::= { prvtCESConformance 1 }
prvtCESDsx1Groups OBJECT IDENTIFIER ::= { prvtCESConformance 2 }
-- compliance statements
prvtCESDsx1Compliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for management of TDM ports."
MODULE -- this module
MANDATORY-GROUPS {
prvtCESDsx1NotificationsGroup,
prvtCESDsx1ROGroup
}
::= { prvtCESDsx1Compliances 1 }
prvtCESDsx1NotificationsGroup NOTIFICATION-GROUP
NOTIFICATIONS { prvtCESDsx1Alarm }
STATUS current
DESCRIPTION
"The group of supported notifications."
::= { prvtCESDsx1Groups 1 }
prvtCESDsx1ROGroup OBJECT-GROUP
OBJECTS { prvtCESE1Impedance,
prvtCEST1GainLimit,
prvtCESModuleLineType,
prvtCESModuleTxClock,
prvtCESModuleConfig,
prvtCESModuleIPAddress,
prvtCESModuleIPAddressMask,
prvtCESModuleGateway,
prvtCESDsx1AlarmThreshold
}
STATUS current
DESCRIPTION
"The group of objects with MAX-ACCESS read-write supported with read-only access for the first release."
::= { prvtCESDsx1Groups 2 }
END