-- ** Filename: PRVT-CONFIGCHANGE-MIB
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-CONFIGCHANGE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowPointer,
DisplayString
FROM SNMPv2-TC
switch
FROM PRVT-SWITCH-MIB;
prvtConfigChangeMIB MODULE-IDENTITY
LAST-UPDATED "200907130000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Initial version. This MIB will provied traps for change"
-- Revision history.
REVISION "200907130000Z"
DESCRIPTION
"Add object snmpServerStatus and notification snmpServerStatusChange"
REVISION "200611200000Z"
DESCRIPTION
"Initial release"
::= { switch 150 }
prvtConfigChangeAlarmOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The configChangeAlarmOID specifies the OID of an object whose value has been changed."
::= {prvtConfigChangeObjects 1}
prvtConfigChangeAlarmRow OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The configChangeAlarmRow specifies the OID of the row from table, whose entry has been changed."
::= {prvtConfigChangeObjects 2}
cliConfigChangeNodePrompt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows the CLI prompt."
::= {prvtConfigChangeObjects 3}
cliConfigChangeCommand OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows executed command."
::= {prvtConfigChangeObjects 4}
snmpServerStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows the enabled/disabled status of the SNMP server."
::= {prvtConfigChangeObjects 5}
prvtConfigChangeAlarm NOTIFICATION-TYPE
OBJECTS {prvtConfigChangeAlarmOID, prvtConfigChangeAlarmRow}
STATUS current
DESCRIPTION
"This notification is generated when the value of configurable
attribute has been changed. The notification can be used
to trigger maintenance polling of the running configuration
on the device. One of the varbinds will point either to entry
of the modified table (configChangeAlarmRow) or the
OID of the modified scalar object "
::= { prvtConfigChangeNotifications 1}
cliConfigurationChange NOTIFICATION-TYPE
OBJECTS {cliConfigChangeNodePrompt,cliConfigChangeCommand}
STATUS current
DESCRIPTION
"This notification is generated when command in configuration node is executed."
::= { prvtConfigChangeNotifications 2}
snmpServerStatusChange NOTIFICATION-TYPE
OBJECTS {
snmpServerStatus
}
STATUS current
DESCRIPTION
"The notification shall be sent whenever the enabled/disabled status
of the SNMP server changes. If the status is changed
from enabled to disabled, the notification shall be sent
prior to disabling the SNMP server."
::= {prvtConfigChangeNotifications 3}
prvtConfigChangeNotifications OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 0 }
prvtConfigChangeObjects OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 1 }
prvtConfigChangeConformance OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 3 }
END