298 lines
8.6 KiB
Plaintext
298 lines
8.6 KiB
Plaintext
-- *********************************************************************
|
||
-- *********************************************************************
|
||
-- ** Filename: PRVT-NETWORK-LOOPBACK-TEST-MIB
|
||
-- ** Project: Network Loopback Tester
|
||
-- ** Purpose: Private MIB
|
||
-- *********************************************************************
|
||
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
||
-- WARNING:
|
||
--
|
||
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
||
--
|
||
-- This file is the property of BATM Advanced Communications.
|
||
-- BATM Advanced Communications retains all title and
|
||
-- ownership in the Specification, including any revisions.
|
||
|
||
-- BATM Advanced Communications grants all interested parties a non-exclusive
|
||
-- license to use and distribute an unmodified copy of this
|
||
-- Specification in connection with management of BATM Advanced Communications
|
||
-- and Telco Systems products, and without fee, provided that the following
|
||
-- conditions are met:
|
||
-- 1. Redistributions of this specification must retain the above copyright
|
||
-- notice, this list of conditions and the following disclaimer.
|
||
-- 2. Redistributions in binary form must reproduce the above copyright
|
||
-- notice, this list of conditions and the following disclaimer in the
|
||
-- documentation and/or other materials provided with the distribution.
|
||
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
|
||
-- or promote products derived from this specification without specific prior written
|
||
-- permission.
|
||
--
|
||
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
||
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
|
||
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
||
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
||
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
||
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
||
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
||
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
||
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
||
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
|
||
PRVT-MONITOR-SESSION-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
Integer32
|
||
FROM SNMPv2-SMI
|
||
|
||
|
||
|
||
MODULE-COMPLIANCE,
|
||
OBJECT-GROUP
|
||
FROM SNMPv2-CONF
|
||
|
||
|
||
-- [RFC2578]
|
||
|
||
DisplayString,
|
||
TEXTUAL-CONVENTION
|
||
FROM SNMPv2-TC
|
||
|
||
PortList
|
||
FROM Q-BRIDGE-MIB
|
||
|
||
switch
|
||
FROM PRVT-SWITCH-MIB;
|
||
|
||
-- The MONITOR SESSION MIB
|
||
prvtMonitorSessionMib MODULE-IDENTITY
|
||
|
||
LAST-UPDATED "201105230000Z"
|
||
ORGANIZATION "BATM Advanced Communication"
|
||
CONTACT-INFO
|
||
"BATM/Telco Systems Support team
|
||
Email:
|
||
For North America: techsupport@telco.com
|
||
For North Europe: support@batm.de, info@batm.de
|
||
For the rest of the world: techsupport@telco.com"
|
||
|
||
DESCRIPTION
|
||
"This MIB contains manageable objects for
|
||
encapsulating Switched Port Analyzer(SPAN) feature."
|
||
|
||
REVISION "201105230000Z"
|
||
DESCRIPTION
|
||
"Initial version."
|
||
|
||
::= { switch 1000 }
|
||
|
||
|
||
-- -------------------------------------------------------------
|
||
-- Textual Conventions
|
||
-- -------------------------------------------------------------
|
||
Direction ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Monitor direction:
|
||
tx- Transmit
|
||
rx- Receive"
|
||
SYNTAX INTEGER
|
||
{
|
||
rx(1),
|
||
tx(2)
|
||
}
|
||
-- -------------------------------------------------------------
|
||
-- groups in the PRVT-MONITOR-SESSION MIB
|
||
-- -------------------------------------------------------------
|
||
prvtMonitorSessionNotification OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 0 }
|
||
prvtMonitorSessionObjects OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 1 }
|
||
prvtMonitorSessionConformance OBJECT IDENTIFIER ::= { prvtMonitorSessionMib 2 }
|
||
|
||
-- -------------------------------------------------------------
|
||
-- prvtMonitorSessionObjects group
|
||
-- -------------------------------------------------------------
|
||
prvtMonitorSessionTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtMonitorSessionEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object for enable and configure Enable Switched Port Analyzer."
|
||
::= { prvtMonitorSessionObjects 1 }
|
||
|
||
prvtMonitorSessionEntry OBJECT-TYPE
|
||
SYNTAX PrvtMonitorSessionEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the table will describe all parameteres of Switched Port Analyzer per each direction Rx or Tx "
|
||
INDEX { prvtMonitorSessionDirection }
|
||
::= {prvtMonitorSessionTable 1}
|
||
|
||
PrvtMonitorSessionEntry ::= SEQUENCE{
|
||
prvtMonitorSessionDirection Direction,
|
||
prvtMonitorSessionSource PortList,
|
||
prvtMonitorSessionDestination Integer32
|
||
}
|
||
|
||
prvtMonitorSessionDirection OBJECT-TYPE
|
||
SYNTAX Direction
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Direction recived/trasmitted of the monitored traffic."
|
||
::= {prvtMonitorSessionEntry 1}
|
||
|
||
prvtMonitorSessionSource OBJECT-TYPE
|
||
SYNTAX PortList
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Monitored source list representing the ports to be mirrored."
|
||
::= {prvtMonitorSessionEntry 2}
|
||
|
||
|
||
|
||
prvtMonitorSessionDestination OBJECT-TYPE
|
||
SYNTAX Integer32
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Analyzer port."
|
||
::= {prvtMonitorSessionEntry 3}
|
||
|
||
prvtAnalyzerVLANTagTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PrvtAnalyzerVLANTagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This table contains object for enable and configure Remote Analyzer VLAN Tag"
|
||
::= { prvtMonitorSessionObjects 2 }
|
||
|
||
prvtAnalyzerVLANTagEntry OBJECT-TYPE
|
||
SYNTAX PrvtAnalyzerVLANTagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the table will describe all parameteres of Remote Analyzer VLAN Tag per each direction Rx or Tx "
|
||
INDEX { prvtMonitorSessionDirection }
|
||
::= {prvtAnalyzerVLANTagTable 1}
|
||
|
||
PrvtAnalyzerVLANTagEntry ::= SEQUENCE{
|
||
prvtAnalyzerVLANTagEnable INTEGER,
|
||
prvtAnalyzerVLANTagVID Integer32,
|
||
prvtAnalyzerVLANTagEtherType DisplayString,
|
||
prvtAnalyzerVLANTagCFI INTEGER,
|
||
prvtAnalyzerVLANTagVPT INTEGER
|
||
}
|
||
|
||
prvtAnalyzerVLANTagEnable OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
enable(1),
|
||
disable(2)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable Remote Analyzer VLAN Tag."
|
||
::= {prvtAnalyzerVLANTagEntry 1}
|
||
|
||
prvtAnalyzerVLANTagVID OBJECT-TYPE
|
||
SYNTAX Integer32 (1..4095)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The VLAN ID of the VLAN tag added to packet forwarded to Analyzer."
|
||
::= {prvtAnalyzerVLANTagEntry 2}
|
||
|
||
|
||
prvtAnalyzerVLANTagEtherType OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Vlan ether type of the VLAN tag added to packet forwarded to Analyzer."
|
||
::= {prvtAnalyzerVLANTagEntry 3}
|
||
|
||
|
||
prvtAnalyzerVLANTagCFI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
clear(0),
|
||
set(1)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The CFI of the VLAN tag added to packet forwarded to Analyzer."
|
||
::= {prvtAnalyzerVLANTagEntry 4}
|
||
|
||
prvtAnalyzerVLANTagVPT OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
{
|
||
vpt-value0(0),
|
||
vpt-value1(1),
|
||
vpt-value2(2),
|
||
vpt-value3(3),
|
||
vpt-value4(4),
|
||
vpt-value5(5),
|
||
vpt-value6(6),
|
||
vpt-value7(7),
|
||
undefined(8)
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The VPT of the VLAN tag added to packet forwarded to Analyzer."
|
||
::= {prvtAnalyzerVLANTagEntry 5}
|
||
|
||
-- ----------------------------------------------------------------------------
|
||
-- Notifications
|
||
-- ----------------------------------------------------------------------------
|
||
|
||
-- ----------------------------------------------------------------------------
|
||
-- Conformance Information
|
||
-- ----------------------------------------------------------------------------
|
||
prvtMonitorSessionCompliances OBJECT IDENTIFIER ::= {prvtMonitorSessionConformance 1}
|
||
prvtMonitorSessionGroups OBJECT IDENTIFIER ::= {prvtMonitorSessionConformance 2}
|
||
|
||
-- compliance statements
|
||
prvtMonitorSessionCompliance MODULE-COMPLIANCE
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The compliance statement for Switched Port Analyzer."
|
||
MODULE -- this module
|
||
MANDATORY-GROUPS {
|
||
prvtMonitorSessionMirroredGroup,
|
||
prvtMonitorSessionAnalyzerGroup
|
||
}
|
||
::= {prvtMonitorSessionCompliances 1}
|
||
|
||
prvtMonitorSessionMirroredGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
prvtMonitorSessionSource
|
||
} STATUS current
|
||
DESCRIPTION
|
||
"The group of objects dedicated to mirrored source."
|
||
::= {prvtMonitorSessionGroups 1}
|
||
|
||
prvtMonitorSessionAnalyzerGroup OBJECT-GROUP
|
||
OBJECTS {
|
||
prvtMonitorSessionDestination,
|
||
prvtAnalyzerVLANTagEnable
|
||
} STATUS current
|
||
DESCRIPTION
|
||
"The group of objects dedicated to analyzer."
|
||
::= {prvtMonitorSessionGroups 2}
|
||
|
||
END
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|