mibs/MIBS/telco-systems/binos/PRVT-RESILIENT-LINK-MIB
2023-12-05 12:25:34 +01:00

252 lines
8.8 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
--
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE FROM SNMPv2-SMI
NOTIFICATION-GROUP FROM SNMPv2-CONF
switch FROM PRVT-SWITCH-MIB;
-------------------------------------------------------------------------------
-- PRIVATE BRANCH PRODUCTS
-------------------------------------------------------------------------------
prvtResilientLinkMib MODULE-IDENTITY
LAST-UPDATED "200502160000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The Resilient Link MIB module for managing switch or ipSwitch
resilient link"
-- revision history
REVISION "200502160000Z"
DESCRIPTION
"Fixed spelling errors and changed the contact info."
REVISION "200305060000Z"
DESCRIPTION
"Move to SMI-V2."
REVISION "200201280000Z"
DESCRIPTION
"Initial version."
::= { switch 102 }
-- -----------------------------------------------------------------------------
-- resilient link configuration parameters
-- -----------------------------------------------------------------------------
prvtResilientLinkNotifications OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
resilientLinkStatus OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
prvtResilientLinkConformance OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
resilientLinkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link configuration."
::= { resilientLinkConfig 1 }
resilientLinkConfigEntry OBJECT-TYPE
SYNTAX ResilientLinkConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkConfigTable 1 }
ResilientLinkConfigEntry ::= SEQUENCE {
resilientLinkIndex INTEGER,
resilientLinkEnable INTEGER,
resilientLinkPort1ifIndex INTEGER,
resilientLinkPort2ifIndex INTEGER,
resilientLinkPreferredPort INTEGER,
resilientLinkActivePort INTEGER
}
resilientLinkIndex OBJECT-TYPE
SYNTAX INTEGER(0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the resilient link"
::= { resilientLinkConfigEntry 1 }
resilientLinkEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables or disables the resilient link"
::= { resilientLinkConfigEntry 2 }
resilientLinkPort1ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the first port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 3 }
resilientLinkPort2ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the second port belonging to this
resilient link; zero means no port is selected"
::= { resilientLinkConfigEntry 4 }
resilientLinkPreferredPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the preferred port (1 or 2) in this
resilient link; zero means no port is preferred"
::= { resilientLinkConfigEntry 5 }
resilientLinkActivePort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkConfigEntry 6 }
-- -----------------------------------------------------------------------------
-- resilient link status
-- -----------------------------------------------------------------------------
resilientLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the resilient link status."
::= { resilientLinkStatus 2 }
resilientLinkStatusEntry OBJECT-TYPE
SYNTAX ResilientLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"resilientLinkIndex"
INDEX { resilientLinkIndex }
::= { resilientLinkStatusTable 1 }
ResilientLinkStatusEntry ::= SEQUENCE {
resilientLinkConnectedPort INTEGER,
resilientLinkCurrentActivePort INTEGER
}
resilientLinkConnectedPort OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
port1Connected(2),
port2Connected(3),
port1and2Connected(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object shows the connected ports in the resilient link"
::= { resilientLinkStatusEntry 1 }
resilientLinkCurrentActivePort OBJECT-TYPE
SYNTAX INTEGER {
noActivePort (1),
port1Active (2),
port2Active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the active port (1 or 2) in this
resilient link. Only ports with link up can be configured as active
ports."
::= { resilientLinkStatusEntry 2 }
-- Traps for use by prvtResilientLinkMib
resilientLinkStatusChange NOTIFICATION-TYPE
OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
resilientLinkCurrentActivePort}
STATUS current
DESCRIPTION
"The resilientLinkStatusChange trap indicates that
the sending agent monitor detected a change in the status of the
resilient link, identified by resilientLinkIndex."
::= {prvtResilientLinkNotifications 1}
-- *******************************************************************
-- Conformance Information
-- *******************************************************************
prvtResilientLinkMIBGroups OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
resilientLinkNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
resilientLinkStatusChange
}
STATUS current
DESCRIPTION
"Private Notification Group."
::= { prvtResilientLinkMIBGroups 3 }
END