-- ** BATM Advanced Communications.
|
|
-- **
|
|
-- *********************************************************************
|
|
-- ** Filename: PRVT-RESILIENT-LINK-MIB.mib
|
|
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
|
|
-- ** Purpose: Private MIB
|
|
-- *********************************************************************
|
|
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
|
|
-- WARNING:
|
|
--
|
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|
--
|
|
-- This file is the property of BATM Advanced Communications and contains
|
|
-- proprietary and confidential information. This file is made
|
|
-- available to authorized BATM customers on the express
|
|
-- condition that neither it, nor any of the information contained
|
|
-- therein, shall be disclosed to third parties or be used for any
|
|
-- purpose other than to replace, modify or upgrade firmware and/or
|
|
-- software components of BATM manufactured equipment within the
|
|
-- authorized customer's network, and that such transfer be
|
|
-- completed in accordance with the instructions provided by
|
|
-- BATM. Any other use is strictly prohibited.
|
|
--
|
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|
--
|
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
--
|
|
PRVT-RESILIENT-LINK-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
switch FROM PRVT-SWITCH-MIB;
|
|
-------------------------------------------------------------------------------
|
|
-- PRIVATE BRANCH PRODUCTS
|
|
-------------------------------------------------------------------------------
|
|
|
|
|
|
prvtResilientLinkMib MODULE-IDENTITY
|
|
LAST-UPDATED "200502160000Z"
|
|
ORGANIZATION "BATM Advanced Communication"
|
|
CONTACT-INFO
|
|
|
|
"BATM/Telco Systems Support team
|
|
Email:
|
|
For North America: techsupport@telco.com
|
|
For North Europe: support@batm.de, info@batm.de
|
|
For the rest of the world: techsupport@telco.com"
|
|
|
|
DESCRIPTION
|
|
"The Resilient Link MIB module for managing switch or ipSwitch
|
|
resilient link"
|
|
|
|
-- revision history
|
|
REVISION "200502160000Z"
|
|
DESCRIPTION
|
|
"Fixed spelling errors and changed the contact info."
|
|
|
|
REVISION "200305060000Z"
|
|
DESCRIPTION
|
|
"Move to SMI-V2."
|
|
|
|
REVISION "200201280000Z"
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { switch 102 }
|
|
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- resilient link configuration parameters
|
|
-- -----------------------------------------------------------------------------
|
|
prvtResilientLinkNotifications OBJECT IDENTIFIER ::= { prvtResilientLinkMib 0 }
|
|
resilientLinkConfig OBJECT IDENTIFIER ::= { prvtResilientLinkMib 1 }
|
|
resilientLinkStatus OBJECT IDENTIFIER ::= { prvtResilientLinkMib 2 }
|
|
prvtResilientLinkConformance OBJECT IDENTIFIER ::= { prvtResilientLinkMib 3 }
|
|
|
|
resilientLinkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ResilientLinkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the resilient link configuration."
|
|
::= { resilientLinkConfig 1 }
|
|
|
|
resilientLinkConfigEntry OBJECT-TYPE
|
|
SYNTAX ResilientLinkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"resilientLinkIndex"
|
|
INDEX { resilientLinkIndex }
|
|
::= { resilientLinkConfigTable 1 }
|
|
|
|
ResilientLinkConfigEntry ::= SEQUENCE {
|
|
resilientLinkIndex INTEGER,
|
|
resilientLinkEnable INTEGER,
|
|
resilientLinkPort1ifIndex INTEGER,
|
|
resilientLinkPort2ifIndex INTEGER,
|
|
resilientLinkPreferredPort INTEGER,
|
|
resilientLinkActivePort INTEGER
|
|
}
|
|
|
|
resilientLinkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..256)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the resilient link"
|
|
::= { resilientLinkConfigEntry 1 }
|
|
|
|
resilientLinkEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables or disables the resilient link"
|
|
::= { resilientLinkConfigEntry 2 }
|
|
|
|
resilientLinkPort1ifIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the first port belonging to this
|
|
resilient link; zero means no port is selected"
|
|
::= { resilientLinkConfigEntry 3 }
|
|
|
|
resilientLinkPort2ifIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the second port belonging to this
|
|
resilient link; zero means no port is selected"
|
|
::= { resilientLinkConfigEntry 4 }
|
|
|
|
resilientLinkPreferredPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the preferred port (1 or 2) in this
|
|
resilient link; zero means no port is preferred"
|
|
::= { resilientLinkConfigEntry 5 }
|
|
|
|
resilientLinkActivePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the active port (1 or 2) in this
|
|
resilient link. Only ports with link up can be configured as active
|
|
ports."
|
|
::= { resilientLinkConfigEntry 6 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- resilient link status
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
resilientLinkStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ResilientLinkStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the resilient link status."
|
|
::= { resilientLinkStatus 2 }
|
|
|
|
resilientLinkStatusEntry OBJECT-TYPE
|
|
SYNTAX ResilientLinkStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"resilientLinkIndex"
|
|
INDEX { resilientLinkIndex }
|
|
::= { resilientLinkStatusTable 1 }
|
|
|
|
ResilientLinkStatusEntry ::= SEQUENCE {
|
|
resilientLinkConnectedPort INTEGER,
|
|
resilientLinkCurrentActivePort INTEGER
|
|
}
|
|
|
|
resilientLinkConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notConnected(1),
|
|
port1Connected(2),
|
|
port2Connected(3),
|
|
port1and2Connected(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows the connected ports in the resilient link"
|
|
::= { resilientLinkStatusEntry 1 }
|
|
|
|
resilientLinkCurrentActivePort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noActivePort (1),
|
|
port1Active (2),
|
|
port2Active (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the active port (1 or 2) in this
|
|
resilient link. Only ports with link up can be configured as active
|
|
ports."
|
|
::= { resilientLinkStatusEntry 2 }
|
|
|
|
-- Traps for use by prvtResilientLinkMib
|
|
|
|
resilientLinkStatusChange NOTIFICATION-TYPE
|
|
OBJECTS { resilientLinkIndex, resilientLinkConnectedPort,
|
|
resilientLinkCurrentActivePort}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resilientLinkStatusChange trap indicates that
|
|
the sending agent monitor detected a change in the status of the
|
|
resilient link, identified by resilientLinkIndex."
|
|
::= {prvtResilientLinkNotifications 1}
|
|
|
|
-- *******************************************************************
|
|
-- Conformance Information
|
|
-- *******************************************************************
|
|
|
|
prvtResilientLinkMIBGroups OBJECT IDENTIFIER ::= { prvtResilientLinkConformance 2 }
|
|
|
|
resilientLinkNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
resilientLinkStatusChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Private Notification Group."
|
|
::= { prvtResilientLinkMIBGroups 3 }
|
|
|
|
END
|