mibs/MIBS/telco-systems/binos/PRVT-SWITCH-MIB
2023-12-05 12:25:34 +01:00

1907 lines
51 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-SWITCH-MIB.mib
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
--
--
PRVT-SWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Integer32,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString,
TruthValue
FROM SNMPv2-TC
NOTIFICATION-GROUP
FROM SNMPv2-CONF
privateVendorOID
FROM PRIV-VENDORDEF-MIB
ifIndex,
ifAdminStatus,
ifOperStatus
FROM IF-MIB;
prvtSwitchMib MODULE-IDENTITY
LAST-UPDATED "200906220000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
" BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The switch MIB module for managing switch
parameters"
-- revision history
REVISION "200906220000Z"
DESCRIPTION
"Add value unsupported(255) for object configL2IfaceAdminCrossOver."
REVISION "200904140000Z"
DESCRIPTION
"Add description for reportsHardwareFanStatus 0."
REVISION "200903080000Z"
DESCRIPTION
"Updated devices system OIDs."
REVISION "200902200000Z"
DESCRIPTION
"Add support for temperature high limit (reportsHardwareTemperatureScale,reportsHardwareTemperatureHighLimit)."
REVISION "200901120000Z"
DESCRIPTION
"Mark configL2IfaceDuplexSpeedSet. Add additional 10G value for
configL2IfaceDuplexSpeedSet and reportsL2IfaceDuplexSpeedGet"
REVISION "200809250000Z"
DESCRIPTION
"Add support for crossover and remote-fault-detect."
REVISION "200803280000Z"
DESCRIPTION
"Updated devices system OIDs."
REVISION "200802280000Z"
DESCRIPTION
"Added OIDs of various devices."
REVISION "200712280000Z"
DESCRIPTION
"Added sysAssemblyNumber, sysPartNumber, sysCLEI, sysHwRevision, sysManufacturingDate objects"
REVISION "200712120000Z"
DESCRIPTION
"Added configL2IfaceMtu."
REVISION "200709260000Z"
DESCRIPTION
"Added new objects in configL2IfaceTable"
REVISION "200704240000Z"
DESCRIPTION
"Updated OID definitions"
REVISION "200702060000Z"
DESCRIPTION
"Updated description of reportsHardwarePSStatus object"
REVISION "200610250000Z"
DESCRIPTION
"New OID group added"
REVISION "200607020000Z"
DESCRIPTION
"Added T-Metro-ES and Alcatel system OID."
REVISION "200606140000Z"
DESCRIPTION
"Changed mMiRIC-E1(89) to mMiRIC-E3(89)"
REVISION "200604200000Z"
DESCRIPTION
"Added new duplex and speed values"
REVISION "200602100000Z"
DESCRIPTION
"Added all missing port/module types"
REVISION "200602020000Z"
DESCRIPTION
"Defined the DUAL SFP module type"
REVISION "200512220000Z"
DESCRIPTION
"Added new object identifier for devices.
Added new notification sysIntfModuleChange.
Changed ModuleHwType modules that had '_' in them, should be with '-' instaead
m100BaseGBIC_not_installed to m100BaseGBIC-not-installed.
mCES_4TDM to mCES-4TDM,
m1250BaseSingleFiber_SFP to m1250BaseSingleFiber-SFP."
REVISION "200512080000Z"
DESCRIPTION
"Added the new sysIntfModuleChange notification for T-Metro devices."
REVISION "200510030000Z"
DESCRIPTION
"Returned the old duplex-speed mixed object for backward compatability"
REVISION "200509260000Z"
DESCRIPTION
"Separated the duplex mode and speed setting in the configL2Table"
REVISION "200509070000Z"
DESCRIPTION
"Added the m1250BaseSingleFiber_SFP(87) port type"
REVISION "200507200000Z"
DESCRIPTION
"Added the mCES_4TDM(86) port type"
REVISION "200507080000Z"
DESCRIPTION
"Removed the range values for reportsL2IfaceUnit, reportsL2IfaceSlot and
reportsL2IfacePort."
REVISION "200503070000Z"
DESCRIPTION
"Added the mCES and 31000BaseX-SFP module types for T-Metro devices."
REVISION "200502160000Z"
DESCRIPTION
"Fixed spelling errors and changed the contact info."
REVISION "200502010000Z"
DESCRIPTION
"Added TMetro to sysProductsOids, added new module types: tMetroCES,
tMetro2XSFPuplink, tMetro2F, tMetro1G"
REVISION "200406290000Z"
DESCRIPTION
"Added T6Pro to sysProductsOids, added a new module type CPM"
REVISION "200405030000Z"
DESCRIPTION
"Added support for exposing the switch series"
REVISION "200403030000Z"
DESCRIPTION
"L2 Interface name (configL2IfaceName) max size changed from 16 to 256."
REVISION "200402030000Z"
DESCRIPTION
"Addded m100BaseGBIC_not_installed to ModuleHwType."
REVISION "200311180000Z"
DESCRIPTION
"Added sysManufacturing group,sysSerialNumber."
REVISION "200310160000Z"
DESCRIPTION
"1. Added portRedundantLinkChange notification.
2. Added reportsIfJack. This table enables support of interfaces attached to
more then one physical interface.
3. Added reportsL2IfaceActiveJackIndex."
REVISION "200309090000Z"
DESCRIPTION
"Added SFP port types."
REVISION "200307020000Z"
DESCRIPTION
"Added support for reporting hardware port type"
REVISION "200305060000Z"
DESCRIPTION
"Move to SMI-V2."
REVISION "200212120000Z"
DESCRIPTION
"Added support for controlling STP topology change detection"
REVISION "200212010000Z"
DESCRIPTION
"Added support for Sniffer"
REVISION "200211210000Z"
DESCRIPTION
"Added support for RSTP"
REVISION "200211170000Z"
DESCRIPTION
"Added support for POS interface speed 155 & 622 M."
REVISION "200209090000Z"
DESCRIPTION
"Added new module for T5Pro including ATM/MLP and 5 ports SM/MM."
REVISION "200204100000Z"
DESCRIPTION
"Add traps."
REVISION "200108140000Z"
DESCRIPTION
"Distinction between set & get flow type to support flow auto-negotiation."
REVISION "200107220000Z"
DESCRIPTION
"Added Default VLAN to configL2IfaceTable"
REVISION "200107150000Z"
DESCRIPTION
"Added new sysIntfModule types m1000BaseGBIC_installed/not_installed"
REVISION "200105170000Z"
DESCRIPTION
"Added t5ProRouter."
REVISION "200105150000Z"
DESCRIPTION
"Added reportsHardware group."
REVISION "200104190000Z"
DESCRIPTION
"Added config & reports group."
REVISION "200104150000Z"
DESCRIPTION
"Added new modules to sysIntfModule."
REVISION "200006280000Z"
DESCRIPTION
"Initial version."
::= { switch 100 }
--
-- PRIVATE BRANCH PRODUCTS
--
prvt-products OBJECT IDENTIFIER ::= { privateVendorOID 1 }
prvt-mgmt OBJECT IDENTIFIER ::= { privateVendorOID 2 }
rptr OBJECT IDENTIFIER ::= { prvt-products 1 }
bridge OBJECT IDENTIFIER ::= { prvt-products 2 }
trclam OBJECT IDENTIFIER ::= { prvt-products 3 }
router OBJECT IDENTIFIER ::= { prvt-products 4 }
switch OBJECT IDENTIFIER ::= { prvt-products 5 }
ipSwitch OBJECT IDENTIFIER ::= { prvt-products 6 }
--
-- L2 SWITCHES
--
bsw OBJECT IDENTIFIER ::= { switch 1 }
tps OBJECT IDENTIFIER ::= { switch 2 }
tpf OBJECT IDENTIFIER ::= { switch 3 }
titan OBJECT IDENTIFIER ::= { switch 5 }
titant5 OBJECT IDENTIFIER ::= { switch 7 }
edgeLinkT4 OBJECT IDENTIFIER ::= { switch 15 }
edgeLinkT5 OBJECT IDENTIFIER ::= { switch 17 }
titanPro OBJECT IDENTIFIER ::= { switch 20}
acs25L4282 OBJECT IDENTIFIER ::= { switch 500 }
acs25L4282t5 OBJECT IDENTIFIER ::= { switch 502 }
vol0215 OBJECT IDENTIFIER ::= { switch 999 }
vol4000 OBJECT IDENTIFIER ::= { switch 998 }
vol5000 OBJECT IDENTIFIER ::= { switch 996 }
--
-- Variable Type definitions
--
UnitIndex ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value represents the physical position of the unit inside the
stack."
SYNTAX INTEGER
{
master(1),
slave1(2),
slave2(3),
slave3(4),
slave4(5)
}
ModuleHwType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value represents the physical type of the port or module."
SYNTAX INTEGER
{
uninstalled(1),
stacking(2),
m100BaseTx(3),
m100BaseFxVF45(4),
m1000BaseSxSCMM850(6),
m1000BaseLxSC1300(7), --Multi/Single Mode
m1000BaseSCSMLDA(8),
m1000BaseSCSMLDB(9),
m1000BaseSxVF45MM850(10),
m1000BaseLxVF451300(11), --Multi/Single Mode
m1000BaseSxMTRJMM(12),
m1000BaseLxMTRJ1300(13), --Multi/Single Mode
m10BaseFlVF45(14),
m10BaseFlVF45X4Ports(15),
m100BaseFxSCMM(16),
m100BaseFxSCSM(17),
m100BaseFxSCSM2Port(18),
m100BaseFxSCSMLD(19),
m100BaseFxSCSMLD2Port(20),
m100BaseFxMTRJMM(21),
m100BaseFxMTRJSM(22),
mDUAL-SFP(23),
mDUAL-SFP-installed(24),
m1000BaseTx(25),
m1000BaseCx(26),
mVDSLNT(30),
mVDSLLT(31),
mVDSLNTand100BaseTX(32),
mVDSLLTand100BaseTX(33),
mVDSLLT24Port(34),
mLayer31000BaseSXSCMM(35),
mLayer31000BaseLXSCSM(36),
mLayer31000BaseSXSFFMM(37),
mLayer31000BaseLXSFFSM(38),
mLayer3100BaseFXSCMM2Port(39),
mLayer3100BaseFXSCSM2Port(40),
mLayer3100BaseFXSCMM4Port(41),
mLayer3100BaseFXSCSM4Port(42),
mLayer3100BaseFXSFFMM(43),
mLayer3100BaseFXSFFSM(44),
mLayer3100BaseTX(45),
m1000BaseGBIC-installed(46),
m1000BaseGBIC-not-installed(47),
mLayer31000BaseSX-GIBIC(48),
mLayer31000BaseLX-GIBIC(49),
mLayer31000BaseCX-GIBIC(50),
mLayer31000BaseT-GIBIC(51),
mLayer3100BaseSMLCL-GIBIC(52),
mLayer3100BaseM5o6SNI-GIBIC(53),
mLayer31000BasePOSMM(54),
mLayer31000BasePOSSM(55),
mLayer3100BaseFXSFFMM20Port(56),
mLayer3100BaseFXSFFSM20Port(57),
mLayer3100BaseFXSFFMM5Port(58),
mLayer3100BaseFXSFFSM5Port(59),
mDS3ATM(60),
mDS1MLP(61),
mMLPmother(62),
m1000BaseSFP-installed(63),
mLayer31000BaseSX-SFP(65),
mLayer31000BaseLX-SFP(66),
mLayer31000BaseCX-SFP(67),
mLayer31000BaseT-SFP(68),
mLayer3100BaseSMLCL-SFP(69),
mLayer3100BaseM5o6SNI-SFP(70),
m100BaseGBIC-not-installed(71),
mLayer310GBaseSR-XFP(72),
mLayer310GBaseLR-XFP(73),
mLayer310GBaseER-XFP(74),
mLayer310GBaseSW-XFP(75),
mLayer310GBaseLW-XFP(76),
mLayer310GBaseEW-XFP(77),
mLayer310GBase-XFP(78),
m10000BaseMEDIA-not-installed(79),
mCpmCard(80),
mLayer310GBaseLRW-XFP(81),
mLayer310GBaseERW-XFP(82),
mLayer31000BaseX-SFP(83),
mCES (84),
mLayer3100BaseFX-SFP(85),
mCES-4TDM(86),
mLayer31000BaseLX-BD-SFP(87),
mMiRIC-E1(88),
mMiRIC-E3(89),
mMiRIC-T1(90),
mMiRIC-T3(91),
mLayer31000BaseSFP-Unknown (92),
m10000BaseXFP-Unknown (93),
xAUI-1G-10G (94),
mLayer3-10-1000BaseT (95),
mLayer310GBaseSMSR-XFP (96),
mLayer310GBaseSMLR-XFP (97),
mLayer310GBaseSMER-XFP (98),
mLayer310GBaseSMSW-XFP (99),
mLayer310GBaseSMLW-XFP (101),
mLayer310GBaseSMEW-XFP (102),
mLayer310GBaseSMSRW-XFP (103),
mLayer310GBaseSMLRW-XFP (104),
mLayer310GBaseSMERW-XFP (105),
mLayer310GBaseCpPgt-XFP (106),
mLayer310GBaseSMZR-XFP (107),
mLayer31000BaseZX-SFP (108),
mLayer310GBaseSMZX-XFP (109),
mLayer310GBaseSMEX-XFP (110),
mLayer31000BaseT-WithoutAN-SFP(111),
mLayer3100BaseLX-BD-SFP(112)
}
Series ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value represents the series of the switch."
SYNTAX INTEGER
{
notExist(1),
e-series(2),
g-series(3),
t-series(4)
}
--
-- Groups
--
prvtSwitchNotifications OBJECT IDENTIFIER ::= { prvtSwitchMib 0 }
sys OBJECT IDENTIFIER ::= { prvtSwitchMib 1 }
config OBJECT IDENTIFIER ::= { prvtSwitchMib 2 }
reports OBJECT IDENTIFIER ::= { prvtSwitchMib 3 }
test OBJECT IDENTIFIER ::= { prvtSwitchMib 4 }
commands OBJECT IDENTIFIER ::= { prvtSwitchMib 5 }
prvtSwitchConformance OBJECT IDENTIFIER ::= { prvtSwitchMib 6 }
--
-- sys group
--
sysProductsOids OBJECT IDENTIFIER ::= { sys 1 }
sysIntf OBJECT IDENTIFIER ::= { sys 2 }
sysManufacturing OBJECT IDENTIFIER ::= { sys 3 }
sysSwitchingHW OBJECT IDENTIFIER ::= { sys 4 }
--
-- sysOids Parameters
--
t4Router OBJECT IDENTIFIER ::= { sysProductsOids 1 }
t5Router OBJECT IDENTIFIER ::= { sysProductsOids 2 }
t5ProRouter OBJECT IDENTIFIER ::= { sysProductsOids 3 }
t6Router OBJECT IDENTIFIER ::= { sysProductsOids 4 }
t5c-48TRouter OBJECT IDENTIFIER ::= { sysProductsOids 5 }
t5RNRouter OBJECT IDENTIFIER ::= { sysProductsOids 6 }
t5c-24TRouter OBJECT IDENTIFIER ::= { sysProductsOids 7 }
t5c-24MRouter OBJECT IDENTIFIER ::= { sysProductsOids 8 }
t5c-24FRouter OBJECT IDENTIFIER ::= { sysProductsOids 9 }
t5c-24GRouter OBJECT IDENTIFIER ::= { sysProductsOids 10 }
t5c-24GTRouter OBJECT IDENTIFIER ::= { sysProductsOids 11 }
t6pro-lc-20G OBJECT IDENTIFIER ::= { sysProductsOids 13 }
t6pro-cpm OBJECT IDENTIFIER ::= { sysProductsOids 14 }
tMetro OBJECT IDENTIFIER ::= { sysProductsOids 16 }
tMarc OBJECT IDENTIFIER ::= { sysProductsOids 17 }
aHUB1-A OBJECT IDENTIFIER ::= { sysProductsOids 18 }
tMetro-ES OBJECT IDENTIFIER ::= { sysProductsOids 19 }
tMarc-E OBJECT IDENTIFIER ::= { sysProductsOids 20 }
tMarc-EW OBJECT IDENTIFIER ::= { sysProductsOids 21 }
tMarc-WDB OBJECT IDENTIFIER ::= { sysProductsOids 22 }
tMarc-WD OBJECT IDENTIFIER ::= { sysProductsOids 23 }
tMarc-F OBJECT IDENTIFIER ::= { sysProductsOids 24 }
t5c-XG OBJECT IDENTIFIER ::= { sysProductsOids 27 }
compact OBJECT IDENTIFIER ::= { t6pro-cpm 1 }
classic OBJECT IDENTIFIER ::= { t6pro-cpm 2 }
as9205 OBJECT IDENTIFIER ::= { t5c-24TRouter 1 }
as9205-F OBJECT IDENTIFIER ::= { t5c-24FRouter 1 }
tMarc-250 OBJECT IDENTIFIER ::= { tMarc 1 }
tMarc-254 OBJECT IDENTIFIER ::= { tMarc 2 }
tMarc-254h OBJECT IDENTIFIER ::= { tMarc 3 }
tMarc-340 OBJECT IDENTIFIER ::= { tMarc 10 }
tMarc-380 OBJECT IDENTIFIER ::= { tMarc 11 }
tMarc-340-E OBJECT IDENTIFIER ::= { tMarc-E 1 }
tMarc-380-E OBJECT IDENTIFIER ::= { tMarc-E 2 }
tMarc-340-EW OBJECT IDENTIFIER ::= { tMarc-EW 1 }
tMarc-380-EW OBJECT IDENTIFIER ::= { tMarc-EW 2 }
tMarc-340WD-B OBJECT IDENTIFIER ::= { tMarc-WDB 1 }
tMarc-340WD OBJECT IDENTIFIER ::= { tMarc-WD 1 }
tMarc-340-F OBJECT IDENTIFIER ::= { tMarc-F 1 }
tMarc-280 OBJECT IDENTIFIER ::= { tMarc 20 }
dm9225 OBJECT IDENTIFIER ::= { tMarc-250 1 }
dm9225-E OBJECT IDENTIFIER ::= { tMarc-254 1 }
dm9234 OBJECT IDENTIFIER ::= { tMarc-340 1 }
alcatel-7250 OBJECT IDENTIFIER ::= { tMetro 1 }
alcatel-7250-ES OBJECT IDENTIFIER ::= { tMetro-ES 1 }
alcatel-7250-ESA OBJECT IDENTIFIER ::= { tMetro-ES 2 }
tMetro-ESA OBJECT IDENTIFIER ::= { tMetro-ES 3 }
as9220 OBJECT IDENTIFIER ::= { tMetro-ES 10 }
tMetro-200S OBJECT IDENTIFIER ::= { tMetro-ES 11 }
as9215 OBJECT IDENTIFIER ::= { t5c-XG 1 }
bI-Ethernet OBJECT IDENTIFIER ::= { aHUB1-A 1 }
fI-Ethernet OBJECT IDENTIFIER ::= { aHUB1-A 2 }
-- Start L2 products
t5c OBJECT IDENTIFIER ::= { sysProductsOids 100 }
t5cgt OBJECT IDENTIFIER ::= { sysProductsOids 222 }
t5g OBJECT IDENTIFIER ::= { sysProductsOids 333 }
v24s OBJECT IDENTIFIER ::= { sysProductsOids 444 }
-- Start VoIP products
edgeGate281 OBJECT IDENTIFIER ::= { sysProductsOids 1000 }
edgeGate281SYS OBJECT IDENTIFIER ::= { sysProductsOids 1001 }
edgeGate231 OBJECT IDENTIFIER ::= { sysProductsOids 1010 }
edgeGate282 OBJECT IDENTIFIER ::= { sysProductsOids 1020 }
edgeGate282S OBJECT IDENTIFIER ::= { sysProductsOids 1021 }
edgeGate482S OBJECT IDENTIFIER ::= { sysProductsOids 1022 }
edgeGate483S OBJECT IDENTIFIER ::= { sysProductsOids 1023 }
edgeGate483D OBJECT IDENTIFIER ::= { sysProductsOids 1024 }
edgeGate201 OBJECT IDENTIFIER ::= { sysProductsOids 1031 }
edgeGate232 OBJECT IDENTIFIER ::= { sysProductsOids 1041 }
ac500 OBJECT IDENTIFIER ::= { sysProductsOids 1050 }
ac505 OBJECT IDENTIFIER ::= { ac500 1 }
ac512 OBJECT IDENTIFIER ::= { ac500 2 }
ac524 OBJECT IDENTIFIER ::= { ac500 3 }
--
-- sys/Interfaces Parameters
--
sysIntfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysIntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the interfaces module type."
::= { sysIntf 1 }
sysIntfEntry OBJECT-TYPE
SYNTAX SysIntfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"sysIntfEntry"
INDEX { sysStackNo, sysSlotNo }
::= { sysIntfTable 1 }
SysIntfEntry ::= SEQUENCE {
sysStackNo UnitIndex,
sysSlotNo Integer32,
sysIntfUnitExist INTEGER,
sysIntfModule ModuleHwType
}
sysStackNo OBJECT-TYPE
SYNTAX UnitIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object identifies the switch"
::= { sysIntfEntry 1 }
sysSlotNo OBJECT-TYPE
SYNTAX Integer32(0..256)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates a single instance of a slot"
::= { sysIntfEntry 2 }
sysIntfUnitExist OBJECT-TYPE
SYNTAX INTEGER {
uninstalled(1),
installed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates interface module type"
::= { sysIntfEntry 3 }
sysIntfModule OBJECT-TYPE
SYNTAX ModuleHwType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This indicates interface module type"
::= { sysIntfEntry 4 }
sysSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the device's serial number, which is entered during the manufacturing process.
"
::= { sysManufacturing 1 }
sysSwitchModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the equipment model"
::= { sysManufacturing 2 }
sysAssemblyNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the equipment assembly number"
::= { sysManufacturing 3 }
sysPartNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the equipment part number"
::= { sysManufacturing 4 }
sysCLEI OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the common language equipment identification"
::= { sysManufacturing 5 }
sysHwRevision OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the HW revision"
::= { sysManufacturing 6 }
sysManufacturingDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies the manufacturing date"
::= { sysManufacturing 7 }
sysSwitchSeries OBJECT-TYPE
SYNTAX Series
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object displays the switch series."
::= { sysSwitchingHW 1 }
--
-- config group
--
--
-- L2 Group
--
--
-- This group provides interface control and information not easily
-- available from other MIBs.
--
configL2 OBJECT IDENTIFIER ::= { config 2 }
configL2SpanOnOff OBJECT-TYPE
SYNTAX INTEGER {
enableSTP(1),
disable(2),
enableRSTP(3),
enablePVST(4),
enableMST(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables/disables Spanning Tree. When Spanning Tree is disabled, the switch's ports are placed in
forwarding mode, regardless of the current Spanning Tree state. When re-enabled, the normal state
transitions take place."
::= { configL2 1 }
configL2IfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigL2IfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Interfaces and their properties"
::= { configL2 2 }
configL2IfaceEntry OBJECT-TYPE
SYNTAX ConfigL2IfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index of interfaces."
INDEX { configL2IfaceUnit, configL2IfaceSlot,configL2IfacePort }
::= { configL2IfaceTable 1 }
ConfigL2IfaceEntry ::= SEQUENCE {
configL2IfaceUnit Integer32,
configL2IfaceSlot Integer32,
configL2IfacePort Integer32,
configL2IfaceName DisplayString,
configL2IfaceEnable INTEGER,
configL2IfaceSTPEnable INTEGER,
configL2IfaceDuplexSpeedSet INTEGER,
configL2IfaceFlow INTEGER,
configL2IfaceBackpressure INTEGER,
configL2IfaceResetCounters INTEGER,
configL2IfaceDefaultVID Integer32,
configL2IfaceSnifferIfIndex Integer32,
configL2TopologyChangeDetection TruthValue,
configL2IfaceDuplexModeSet INTEGER,
configL2IfaceSpeedSet INTEGER,
configL2IfaceBroadcastRateLimit Integer32,
configL2IfaceMulticastRateLimit Integer32,
configL2IfaceUnknownRateLimit Integer32,
configL2IfaceBroadcastBurstSize Integer32,
configL2IfaceMulticastBurstSize Integer32,
configL2IfaceUnknownBurstSize Integer32,
configL2IfaceMtu Integer32,
configL2IfaceAdminCrossOver INTEGER,
configL2IfaceRemoteFaultDetect INTEGER
}
configL2IfaceUnit OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a unit in the
Interface Table."
::= { configL2IfaceEntry 1 }
configL2IfaceSlot OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a slot within the unit
in the Interface Table."
::= { configL2IfaceEntry 2 }
configL2IfacePort OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a port within the slot
in the Interface Table."
::= { configL2IfaceEntry 3 }
configL2IfaceName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The textual name of this interface, e.g., 'John'."
::= { configL2IfaceEntry 4 }
configL2IfaceEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables (1)or disables (2) control for the interface.
For this product, this is the ONLY way to enable or
disable the interface. 'ifAdminStatus' in RFC1213 and
'dot1dStpPortEnable' in RFC1493 are both implemented
as 'read-only'."
::= { configL2IfaceEntry 5 }
configL2IfaceSTPEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables (1) and disables (2) Spanning Tree operation for this
interface."
::= { configL2IfaceEntry 6 }
configL2IfaceDuplexSpeedSet OBJECT-TYPE
SYNTAX INTEGER {
autonegotiate(1),
half-10(2),
full-10(3),
half-100(4),
full-100(5),
half-1000(6),
full-1000(7),
pos-155(8),
pos-622(9),
full-10000(10),
half-auto(11),
full-auto(12),
auto-10(13),
auto-100(14),
auto-1000 (16),
illegal(99)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"The desired speed and duplex mode for the interface. If the selected
control is not available for the interface, a value of illegal (99)
is returned. If the port type does NOT support the
default of autonegotiate (1), then the application will
initialize the port to a valid value (e.g., 1000full (6)).
Note that not all controls are available for all interfaces.
For example, only full-1000 (6) is available for Gigabit
Ethernet interfaces.
As this object was marked as obsolete the following two
configurable parameters of an interface should be used:
configL2IfaceDuplexModeSet, configL2IfaceSpeedSet "
::= { configL2IfaceEntry 7 }
configL2IfaceFlow OBJECT-TYPE
SYNTAX INTEGER {
autonegotiate(1), -- only for giga
flowon(2),
flowoff(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired flow mode for the interface. If the selected control is not available
on the interface, a value of illegal (99) is returned. If the port type does NOT support
the default value of autonegotiate (1), then the application will initialize the port to a
valid value (e.g., 1000full (6)).Note that not all controls are available for all interfaces.
For example, only full-1000 (6) is available for Gigabit Ethernet interfaces."
::= { configL2IfaceEntry 8 }
configL2IfaceBackpressure OBJECT-TYPE
SYNTAX INTEGER {
backpressureon(1),
backpressureoff(2),
illegal(99)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired back-pressure mode for the interface.
If the selected control is not available on the interface,
a value of illegal (99) is returned."
::= { configL2IfaceEntry 9 }
configL2IfaceResetCounters OBJECT-TYPE
SYNTAX INTEGER {
noop(1),
reset(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables resetting the statistics counters selected for this
port."
::= { configL2IfaceEntry 10 }
configL2IfaceDefaultVID OBJECT-TYPE
SYNTAX Integer32(1..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object sets the default VLAN ID according to 802.1Q."
::= { configL2IfaceEntry 11 }
configL2IfaceSnifferIfIndex OBJECT-TYPE
SYNTAX Integer32(0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object connects this port to a sniffer port indexed by the specified ifIndex.
Setting this value to 0 disconnects this port from the sniffer."
::= { configL2IfaceEntry 12 }
configL2TopologyChangeDetection OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls the STP topology change detection for this interface."
::= { configL2IfaceEntry 13 }
configL2IfaceDuplexModeSet OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
full(2),
half(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The duplex mode for the interface. If the port type does NOT support
the default of autonegotiate (1), then the application will
initialize the port to a valid value (e.g., full (2))."
::= { configL2IfaceEntry 14 }
configL2IfaceSpeedSet OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
speed-10(2),
speed-100(3),
speed-1000(4),
speed-10000(5),
pos-155(6),
pos-622(7),
illegal(99)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired speed and duplex mode for the interface. If the selected
control is not available for the interface, a value of illegal (99)
is returned. If the port type does NOT support the
default of autonegotiate (1), then the application will
initialize the port to a valid value (e.g., 1000 (3)).
Note that not all controls are available for all interfaces.
For example, only 1000 (4) is available for Gigabit
Ethernet interfaces."
::= { configL2IfaceEntry 15 }
configL2IfaceBroadcastRateLimit OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate limit broadcast traffic. Must be a number between 64Kbps and 1Gbps,
specified in Kbps."
::= { configL2IfaceEntry 16 }
configL2IfaceMulticastRateLimit OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate limit multicast traffic. Must be a number between 64Kbps and 1Gbps,
specified in Kbps."
::= { configL2IfaceEntry 17 }
configL2IfaceUnknownRateLimit OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate limit unknown traffic. Must be a number between 64Kbps and 1Gbps,
specified in Kbps. For detail information see documentation."
::= { configL2IfaceEntry 18 }
configL2IfaceBroadcastBurstSize OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Burst size broadcast traffic. Must be a number between 12Kbps and 1Mbps,
specified in Kbps."
::= { configL2IfaceEntry 19 }
configL2IfaceMulticastBurstSize OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Burst size multicast traffic. Must be a number between 12Kbps and 1Mbps,
specified in Kbps."
::= { configL2IfaceEntry 20 }
configL2IfaceUnknownBurstSize OBJECT-TYPE
SYNTAX Integer32(-1..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Burst size unknown traffic. Must be a number between 12Kbps and 1Mbps,
specified in Kbps. For detail information see documentation."
::= { configL2IfaceEntry 21 }
configL2IfaceMtu OBJECT-TYPE
SYNTAX Integer32 (512..9216)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maximum Transmission Unit (in octets) of the interface."
DEFVAL { 1528 }
::= { configL2IfaceEntry 22 }
configL2IfaceAdminCrossOver OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
mdi(2),
mdi-x(3),
unsupported(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The administrative MDI/MDI-X cable connection status of ports, as specified in IEEE 803.2.
The mdi-x mode (crossover) is configured (3), the interface works in MDI-X mode.
The mdi mode (2) defines port to work in standard MDI mode.
The auto (1) defines automatic crossover detection, and any type of MDI/MDI-X cabling can be used on the port.
Note: This attribute can be configured only on interfaces that support that option."
::= { configL2IfaceEntry 23 }
configL2IfaceRemoteFaultDetect OBJECT-TYPE
SYNTAX INTEGER {
enableRemoteFaultDetect(1),
disableRemoteFaultDetect(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the remote fault detection on interfaces, connected to 100Base Fiber pair.
Once enabled (1), the switch will indicate link-down event on the interface, once remote
peer detects link down.
Note: Relevant only on 100Base Fiber interfaces."
::= { configL2IfaceEntry 24 }
--
-- reports group
--
reportsL2 OBJECT IDENTIFIER ::= { reports 1 }
--
-- L2 Group
--
--
-- This group provides interface information not easily
-- available from other MIBs.
--
reportsL2IfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF ReportsL2IfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Interfaces and their properties"
::= { reportsL2 1 }
reportsL2IfaceEntry OBJECT-TYPE
SYNTAX ReportsL2IfaceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index of interfaces."
INDEX { reportsL2IfaceUnit, reportsL2IfaceSlot,reportsL2IfacePort }
::= { reportsL2IfaceTable 1 }
ReportsL2IfaceEntry ::= SEQUENCE {
reportsL2IfaceUnit Integer32,
reportsL2IfaceSlot Integer32,
reportsL2IfacePort Integer32,
reportsL2IfaceBridgeIndex Integer32,
reportsL2IfaceType INTEGER,
reportsL2IfaceLink INTEGER,
reportsL2IfaceDuplexSpeedGet INTEGER,
reportsL2IfaceTXOctetsNoErr Counter32,
reportsL2IfaceTXPacketsNoErr Counter32,
reportsL2IfaceRXOctetsNoErr Counter32,
reportsL2IfaceRXPacketsNoErr Counter32,
reportsL2IfaceIfInOctets Counter32,
reportsL2IfaceIfInUcastPkts Counter32,
reportsL2IfaceIfInNUcastPkts Counter32,
reportsL2IfaceIfInDiscards Counter32,
reportsL2IfaceIfInErrors Counter32,
reportsL2IfaceIfInUnknownProtos Counter32,
reportsL2IfaceIfOutOctets Counter32,
reportsL2IfaceIfOutUcastPkts Counter32,
reportsL2IfaceIfOutNUcastPkts Counter32,
reportsL2IfaceIfOutDiscards Counter32,
reportsL2IfaceIfOutErrors Counter32,
reportsL2IfaceStatsDropEvents Counter32,
reportsL2IfaceStatsOctets Counter32,
reportsL2IfaceStatsPkts Counter32,
reportsL2IfaceStatsBroadcastPkts Counter32,
reportsL2IfaceStatsMulticastPkts Counter32,
reportsL2IfaceStatsCRCAlignErrors Counter32,
reportsL2IfaceStatsUndersizePkts Counter32,
reportsL2IfaceStatsOversizePkts Counter32,
reportsL2IfaceStatsFragments Counter32,
reportsL2IfaceStatsJabbers Counter32,
reportsL2IfaceStatsCollisions Counter32,
reportsL2IfaceStatsPkts64Octets Counter32,
reportsL2IfaceStatsPkts65to127Octets Counter32,
reportsL2IfaceStatsPkts128to255Octets Counter32,
reportsL2IfaceStatsPkts256to511Octets Counter32,
reportsL2IfaceStatsPkts512to1023Octets Counter32,
reportsL2IfaceStatsPkts1024to1518Octets Counter32,
reportsL2IfaceFlow INTEGER,
reportsL2IfaceHWType ModuleHwType,
reportsL2IfaceActiveJackIndex Integer32
}
reportsL2IfaceUnit OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a unit in the
Interface Table."
::= { reportsL2IfaceEntry 1 }
reportsL2IfaceSlot OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a slot within the unit
in the Interface Table."
::= { reportsL2IfaceEntry 2 }
reportsL2IfacePort OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index that uniquely identifies a port within the slot
in the Interface Table."
::= { reportsL2IfaceEntry 3 }
reportsL2IfaceBridgeIndex OBJECT-TYPE
SYNTAX Integer32(1..1000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the bridge index of this port."
::= { reportsL2IfaceEntry 4 }
reportsL2IfaceType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
regular1822(2),
hdh1822(3),
ddn-x25(4),
rfc877-x25(5),
ethernet-csmacd(6),
iso88023-csmacd(7),
iso88024-tokenBus(8),
iso88025-tokenRing(9),
iso88026-man(10),
starLan(11),
proteon-10Mbit(12),
proteon-80Mbit(13),
hyperchannel(14),
fddi(15),
lapb(16),
sdlc(17),
ds1(18), -- T-1
e1(19), -- European equivalent of T-1
basicISDN(20),
primaryISDN(21), -- proprietary serial
propPointToPointSerial(22),
ppp(23),
softwareLoopback(24),
eon(25), -- CLNP over IP [11]
ethernet-3Mbit(26),
nsip(27), -- XNS over IP
slip(28), -- generic SLIP
ultra(29), -- ULTRA technologies
ds3(30), -- T-3
sip(31), -- SMDS
frame-relay(32)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface, repeated here from the definitions
in RFC1213 as a matter of convenience."
::= { reportsL2IfaceEntry 5 }
reportsL2IfaceLink OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of Link Detect on the interface."
::= { reportsL2IfaceEntry 6 }
reportsL2IfaceDuplexSpeedGet OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
half-10(2),
full-10(3),
half-100(4),
full-100(5),
half-1000(6),
full-1000(7),
pos-155(8),
pos-622(9),
full-10000(10),
illegal(99)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual speed and duplex for the interface. If the
interface is not configured to one of the acceptable
values, a value of illegal (99) is returned."
::= { reportsL2IfaceEntry 7 }
reportsL2IfaceTXOctetsNoErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets transmitted from the interface. This
number does not include octets with errors."
::= { reportsL2IfaceEntry 8 }
reportsL2IfaceTXPacketsNoErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted from the interface. This
number does not include packets with errors."
::= { reportsL2IfaceEntry 9 }
reportsL2IfaceRXOctetsNoErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets received on the interface. This
number does not include octets with errors."
::= { reportsL2IfaceEntry 10 }
reportsL2IfaceRXPacketsNoErr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received on the interface. This
number does not include packets with errors."
::= { reportsL2IfaceEntry 11 }
reportsL2IfaceIfInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the
interface, including framing characters."
::= { reportsL2IfaceEntry 12 }
reportsL2IfaceIfInUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of subnetwork-unicast packets
delivered to a higher-layer protocol."
::= { reportsL2IfaceEntry 13 }
reportsL2IfaceIfInNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of non-unicast (i.e., subnetwork-
broadcast or subnetwork-multicast) packets
delivered to a higher-layer protocol."
::= { reportsL2IfaceEntry 14 }
reportsL2IfaceIfInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets that were chosen
to be discarded even if no errors that prevent their deliverability
to a higher-layer protocol had been detected. One possible reason for
discarding such a packet could be to free buffer space."
::= { reportsL2IfaceEntry 15 }
reportsL2IfaceIfInErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets that contained
errors preventing them from being deliverable to a
higher-layer protocol."
::= { reportsL2IfaceEntry 16 }
reportsL2IfaceIfInUnknownProtos OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets received via the interface
that were discarded because of an unknown or
unsupported protocol."
::= { reportsL2IfaceEntry 17 }
reportsL2IfaceIfOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
interface, including framing characters."
::= { reportsL2IfaceEntry 18 }
reportsL2IfaceIfOutUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested to be transmitted to a
subnetwork-unicast address, including those that
were discarded or not sent."
::= { reportsL2IfaceEntry 19 }
reportsL2IfaceIfOutNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested to be transmitted to a non-
unicast (i.e., a subnetwork-broadcast or
subnetwork-multicast) address, including those
that were discarded or not sent."
::= { reportsL2IfaceEntry 20 }
reportsL2IfaceIfOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets that were chosen
to be discarded even if no errors that prevented their
transmission had been detected. One
possible reason for discarding such a packet could
be to free up buffer space."
::= { reportsL2IfaceEntry 21 }
reportsL2IfaceIfOutErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets that could not be
transmitted because of errors."
::= { reportsL2IfaceEntry 22 }
reportsL2IfaceStatsDropEvents OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which packets
were dropped by the probe due to lack of resources.
Note that this number is not necessarily the number of
packets dropped; it is just the number of times this
condition has been detected."
::= { reportsL2IfaceEntry 23 }
reportsL2IfaceStatsOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets of data (including
those in bad packets) received on the
network (excluding framing bits but including
FCS octets).
This object can be used as a reasonable estimate of
Ethernet utilization. If greater precision is
desired, the etherStatsPkts and etherStatsOctets
objects should be sampled before and after a common
interval. The differences in the sampled values are
Pkts and Octets, respectively, and the number of
seconds in the interval is Interval. These values
are used to calculate the Utilization as follows:
Pkts * (9.6 + 6.4) + (Octets * .8)
Utilization = -------------------------------------
Interval * 10,000
The result of this equation is the Ethernet segment utilization
which is the percent utilization of the ethernet
segment on a 0 to 100 percent scale."
::= { reportsL2IfaceEntry 24 }
reportsL2IfaceStatsPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad packets,
broadcast packets, and multicast packets) received."
::= { reportsL2IfaceEntry 25 }
reportsL2IfaceStatsBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to the broadcast address. Note that this
does not include multicast packets."
::= { reportsL2IfaceEntry 26 }
reportsL2IfaceStatsMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of good packets received that were
directed to a multicast address. Note that this
number does not include packets directed to the
broadcast address."
::= { reportsL2IfaceEntry 27 }
reportsL2IfaceStatsCRCAlignErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that
had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518
octets, inclusive, but had either a bad
Frame Check Sequence (FCS) with an integral
number of octets (FCS Error) or a bad FCS with
a non-integral number of octets (Alignment Error)."
::= { reportsL2IfaceEntry 28 }
reportsL2IfaceStatsUndersizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
less than 64 octets long (excluding framing bits,
but including FCS octets) and were otherwise well
formed."
::= { reportsL2IfaceEntry 29 }
reportsL2IfaceStatsOversizePkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets) and were otherwise
well formed."
::= { reportsL2IfaceEntry 30 }
reportsL2IfaceStatsFragments OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were less
than 64 octets in length (excluding framing bits but
including FCS octets) and had either a bad Frame
Check Sequence (FCS) with an integral number of
octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Note that it is entirely normal for
etherStatsFragments to increment. This is because
it counts both runts (which are normal occurrences
due to collisions) and noise hits."
::= { reportsL2IfaceEntry 31 }
reportsL2IfaceStatsJabbers OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received that were
longer than 1518 octets (excluding framing bits,
but including FCS octets), and had either a bad
Frame Check Sequence (FCS) with an integral number
of octets (FCS Error) or a bad FCS with a
non-integral number of octets (Alignment Error).
Note that this definition of jabber is different
from the definition in IEEE-802.3 section 8.2.1.5
(10BASE5) and section 10.3.1.4 (10BASE2). These
documents define jabber as the condition in which any
packet exceeds 20 ms. The allowed range to detect
jabber is between 20 ms and 150 ms."
::= { reportsL2IfaceEntry 32 }
reportsL2IfaceStatsCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimate of the total number of collisions
on this Ethernet segment.
The value returned will depend on the RMON probe's location.
Sections 8.2.1.3 (10BASE-5) and 10.3.1.3 (10BASE-2) of
IEEE standard 802.3 states that a station must detect a collision in
the receive mode if three or more stations are
transmitting simultaneously. A repeater port must
detect a collision when two or more stations are
transmitting simultaneously. Thus a probe placed on
a repeater port could record more collisions than a
probe connected to a station on the same segment
would.
Probe location plays a much smaller role when
considering 10BASE-T. Section 14.2.1.4 (10BASE-T) of IEEE
standard 802.3 defines a collision as the
simultaneous presence of signals on the DO and RD
circuits (transmitting and receiving at the same
time). A 10BASE-T station can only detect
collisions when it is transmitting. Thus probes
placed on a station and a repeater, should report
the same number of collisions.
Note also that an RMON probe inside a repeater
should ideally report collisions between the
repeater and one or more other hosts (transmit
collisions as defined by IEEE 802.3k) plus receiver
collisions observed on any coaxial segments to which
the repeater is connected."
::= { reportsL2IfaceEntry 33 }
reportsL2IfaceStatsPkts64Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were 64 octets in length
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 34 }
reportsL2IfaceStatsPkts65to127Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
65 and 127 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 35 }
reportsL2IfaceStatsPkts128to255Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
128 and 255 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 36 }
reportsL2IfaceStatsPkts256to511Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
256 and 511 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 37 }
reportsL2IfaceStatsPkts512to1023Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
512 and 1023 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 38 }
reportsL2IfaceStatsPkts1024to1518Octets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets (including bad
packets) received that were between
1024 and 1518 octets in length inclusive
(excluding framing bits but including FCS octets)."
::= { reportsL2IfaceEntry 39 }
reportsL2IfaceFlow OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
flowon(2),
flowoff(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flow control for the interface."
::= { reportsL2IfaceEntry 40 }
reportsL2IfaceHWType OBJECT-TYPE
SYNTAX ModuleHwType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The HW type of the interface."
::= { reportsL2IfaceEntry 41 }
reportsL2IfaceActiveJackIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current active jack index."
::= { reportsL2IfaceEntry 42 }
reportsHardware OBJECT IDENTIFIER ::= { reports 2 }
--
-- Hardware Group
--
--
-- This group provides general hardware information not from other MIBs.
--
reportsHardwarePSStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each OCTET holds the status of 1 power supply or if supported,
a status of its corresponding power supply fan. Every octet can
show one of the following states:
0 - power supply not installed;
1 - power supply is installed but does not function correctly;
2 - power supply is installed and working OK;
There are devices, which can also show status of the Fan,
attached to the power supply. All devices which support the Power
Supply fan, will display their status in series of octet pairs.
The fan status octet will be displayed right after the supply
status octet. "
::= { reportsHardware 1 }
reportsHardwareFanStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each OCTET holds the status of 1 fan
0 - Fan stopped
1 - Fan failed
2 - Fan OK"
::= { reportsHardware 2 }
reportsHardwareTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The internal temperature of the unit in degrees Celsius."
::= { reportsHardware 3 }
reportsHardwarePSVoltage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each OCTET holds the voltage of a corresponding power supply. Every octet can
show one of the following states:
0 - power supply not installed or voltage information is not supported;
1-C - power supply in V, hexadecimal;"
::= { reportsHardware 4 }
reportsHardwareTemperatureScale OBJECT-TYPE
SYNTAX INTEGER { celsius(1),
fahrenheit(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Displays the scale used - Celsius (Centigrade) or Fahrenheit when measuring CPU temperature. The value of this object determines the type of scale used for the values of reportsHardwareTemperature and reportsHardwareTemperatureHighLimit objects."
DEFVAL { celsius }
::= { reportsHardware 5 }
reportsHardwareTemperatureHighLimit OBJECT-TYPE
SYNTAX INTEGER (20..70)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Displays the highest allowed Celsius (Centigrade) or Fahrenheit temperature at the unit CPU area. When this limit is reached an SNMP notification is sent."
DEFVAL { 55 }
-- Default value in Celsius is 55, or 131 in Fahrenheit; Allowed range is <20-70> for Celsius, <68-158> in Fahrenheit
::= { reportsHardware 6 }
reportsHardwareDoorStatus OBJECT-TYPE
SYNTAX INTEGER (0..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of door
0 - Door not installed
1 - Door open
2 - Door closed"
::= { reportsHardware 7 }
reportsIfJack OBJECT IDENTIFIER ::= { reports 3 }
--
-- Hardware Group
--
--
-- This group provides general hardware information not from other MIBs.
--
reportsIfJackTable OBJECT-TYPE
SYNTAX SEQUENCE OF ReportsIfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about the external jacks attached to
MAUs attached to an interface."
::= { reportsIfJack 2 }
reportsIfJackEntry OBJECT-TYPE
SYNTAX ReportsIfJackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information
about a particular jack."
INDEX { reportsL2IfaceUnit,reportsL2IfaceSlot,
reportsL2IfacePort,reportsIfJackIndex }
::= { reportsIfJackTable 1 }
ReportsIfJackEntry ::=
SEQUENCE {
reportsIfJackIndex Integer32,
reportsIfJackType ModuleHwType
}
reportsIfJackIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This variable uniquely identifies the jack
described by this entry from among other jacks
attached to the same MAU."
::= { reportsIfJackEntry 1 }
reportsIfJackType OBJECT-TYPE
SYNTAX ModuleHwType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The jack connector type, as it appears on the
outer side of the system."
::= { reportsIfJackEntry 2 }
-- Notifications for use by prvtSwitchMib
cpuTemperatureExceeded NOTIFICATION-TYPE
OBJECTS { reportsHardwareTemperature }
STATUS current
DESCRIPTION
"The cpuTemperatuteExceeded trap indicates that the sending
agent senses that the internal temperature has passed the
program threshold."
::= {prvtSwitchNotifications 1}
powerSupplyStatusChange NOTIFICATION-TYPE
OBJECTS { reportsHardwarePSStatus }
STATUS current
DESCRIPTION
"The powerSupplyStatusChange trap indicates that the sending
agent senses a change in the status of one of the power supplies."
::= {prvtSwitchNotifications 2}
fanStatusChange NOTIFICATION-TYPE
OBJECTS { reportsHardwareFanStatus }
STATUS current
DESCRIPTION
"The fanStatusChange trap indicates that the sending
agent senses a change in the status of one of the fans."
::= {prvtSwitchNotifications 3}
portSecurityViolation NOTIFICATION-TYPE
OBJECTS { ifIndex }
STATUS current
DESCRIPTION
"The port security violation notification indicates that a port security violation has been detected, e.g more MAC adresses have been learned on that port than the number allowed."
::= { prvtSwitchNotifications 4}
portRedundantLinkChange NOTIFICATION-TYPE
OBJECTS { ifAdminStatus, ifOperStatus, reportsL2IfaceLink }
STATUS current
DESCRIPTION
"The port redundant link change notification indicates that the physical state of a redundant (i.e.
blocked or discarding) link has changed from link-up
to link down or vice versa."
::= { prvtSwitchNotifications 5}
sysIntfModuleChange NOTIFICATION-TYPE
OBJECTS { sysIntfModule}
STATUS current
DESCRIPTION
"The System Interface Module change notification indicates
that the physical status of a module in the
unit has changed."
::= { prvtSwitchNotifications 6}
prvtLogNotifyFull NOTIFICATION-TYPE
-- OBJECTS { }
STATUS current
DESCRIPTION
"Log buffer is almost full."
::= { prvtSwitchNotifications 7}
doorStatusChange NOTIFICATION-TYPE
OBJECTS { reportsHardwareDoorStatus }
STATUS current
DESCRIPTION
"The doorStatusChange trap indicates that the sending
agent senses a change in the status of the door."
::= {prvtSwitchNotifications 8}
-- *******************************************************************
-- Conformance Information
-- *******************************************************************
prvtSwitchMIBGroups OBJECT IDENTIFIER ::= { prvtSwitchConformance 2 }
prvtSwitchNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
cpuTemperatureExceeded,
powerSupplyStatusChange,
fanStatusChange,
portSecurityViolation,
portRedundantLinkChange,
sysIntfModuleChange,
doorStatusChange
}
STATUS current
DESCRIPTION
"Private Notification Group."
::= { prvtSwitchMIBGroups 3 }
END