mibs/MIBS/telco-systems/binox/PRVT-EPS-MIB
2023-12-05 12:25:34 +01:00

537 lines
19 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-EPS-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-EPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
switch
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtEpsMIB MODULE-IDENTITY
LAST-UPDATED "201011110000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Private MIB supporting Linear Ethernet Protection Switching (ITU-T G.8031)"
REVISION "201011110000Z"
DESCRIPTION
"Initial"
::= { switch 132 }
PrvtEpsProtectionStateType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Possible protection states for an end device."
SYNTAX INTEGER { none(-1), noRequest(0), doNotRevert(1),
reverseRequest(2), exercise(4), waitToRestore(5),
clear(6), manualSwitch(7), signalDegrade(9),
signalFail(11), forcedSwitch(13),
signalFailForProtection(14), lockoutOfProtection(15) }
PrvtEpsActionType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Used to perform an action.
Setting to 'performAction' will cause the action to be performed.
Setting to 'idle' (or any other value except 'performAction') has
no effect (no action is performed).
Reads will always return 'idle'."
SYNTAX INTEGER { idle(1), performAction(2) }
prvtEpsMIBNotifications OBJECT IDENTIFIER
::= { prvtEpsMIB 0 }
prvtEpsMIBObjects OBJECT IDENTIFIER
::= { prvtEpsMIB 1 }
prvtEpsService OBJECT IDENTIFIER
::= { prvtEpsMIBObjects 1 }
prvtEpsServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtEpsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Ethernet Protection Switching services information."
::= { prvtEpsService 1 }
prvtEpsServiceEntry OBJECT-TYPE
SYNTAX PrvtEpsServiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet Protection Switching information about a specific service."
INDEX { prvtEpsSvcId }
::= { prvtEpsServiceTable 1 }
PrvtEpsServiceEntry ::= SEQUENCE {
prvtEpsSvcId Unsigned32,
prvtEpsServiceRowStatus RowStatus,
prvtEpsServiceCfmMdLevel Unsigned32,
prvtEpsServicePrimaryLocalCfmMep Unsigned32,
prvtEpsServicePrimaryRemoteCfmMep Unsigned32,
prvtEpsServiceSecondaryLocalCfmMep Unsigned32,
prvtEpsServiceSecondaryRemoteCfmMep Unsigned32,
prvtEpsServiceSignalDegradeCfmTestId Unsigned32,
prvtEpsServiceRevertive TruthValue,
prvtEpsServiceHoldOffTimer Unsigned32,
prvtEpsServiceWaitToRestoreTimer Unsigned32,
prvtEpsServiceAdminFreeze TruthValue,
prvtEpsServiceAdminStatus INTEGER,
prvtEpsServiceActivePath INTEGER,
prvtEpsServiceDefectsPresent BITS,
prvtEpsServiceLocalState PrvtEpsProtectionStateType,
prvtEpsServiceOperationalStatus TruthValue,
prvtEpsServiceLastEvent INTEGER,
prvtEpsServicePrimaryStatus INTEGER,
prvtEpsServiceSecondaryStatus INTEGER,
prvtEpsServiceRemoteState PrvtEpsProtectionStateType,
prvtEpsServiceRemoteApsChannel INTEGER,
prvtEpsServiceRemoteProtection INTEGER,
prvtEpsServiceRemoteDirection INTEGER,
prvtEpsServiceRemoteRevertive INTEGER,
prvtEpsServiceLocalApsChannel INTEGER,
prvtEpsServiceLocalProtection INTEGER,
prvtEpsServiceLocalDirection INTEGER,
prvtEpsServiceClear PrvtEpsActionType,
prvtEpsServiceManualSwitch PrvtEpsActionType,
prvtEpsServiceForcedSwitch PrvtEpsActionType,
prvtEpsServiceLockout PrvtEpsActionType,
prvtEpsServiceProtectionCounter Unsigned32
}
prvtEpsSvcId OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967294)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The service ID."
::= { prvtEpsServiceEntry 1 }
prvtEpsServiceRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns must have a valid value before a row
can be activated."
::= { prvtEpsServiceEntry 2 }
prvtEpsServiceCfmMdLevel OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of the CFM MD level where the protected domain is situated."
::= { prvtEpsServiceEntry 3 }
prvtEpsServicePrimaryLocalCfmMep OBJECT-TYPE
SYNTAX Unsigned32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Primary local CFM MEP Id."
::= { prvtEpsServiceEntry 4 }
prvtEpsServicePrimaryRemoteCfmMep OBJECT-TYPE
SYNTAX Unsigned32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Primary remote CFM MEP Id."
::= { prvtEpsServiceEntry 5 }
prvtEpsServiceSecondaryLocalCfmMep OBJECT-TYPE
SYNTAX Unsigned32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Backup local CFM MEP Id."
::= { prvtEpsServiceEntry 6 }
prvtEpsServiceSecondaryRemoteCfmMep OBJECT-TYPE
SYNTAX Unsigned32 (1..8191)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Backup remote CFM MEP Id."
::= { prvtEpsServiceEntry 7 }
prvtEpsServiceSignalDegradeCfmTestId OBJECT-TYPE
SYNTAX Unsigned32 (0..256)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ID of the test used for monitoring (either CFM or SAA test).
The value 0 indicates no test."
::= { prvtEpsServiceEntry 8 }
prvtEpsServiceRevertive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Protection type (revertive or non-revertive)."
::= { prvtEpsServiceEntry 9 }
prvtEpsServiceHoldOffTimer OBJECT-TYPE
SYNTAX Unsigned32 (0..10000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of the Hold Off timer in milliseconds.
Valid values are in increments of 100ms."
REFERENCE
"G.8031 clause 11.12"
::= { prvtEpsServiceEntry 10 }
prvtEpsServiceWaitToRestoreTimer OBJECT-TYPE
SYNTAX Unsigned32 (0 | 5..12)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Value of the Wait To Restore timer in seconds (0 to disable it)."
REFERENCE
"G.8031 clause 11.13"
::= { prvtEpsServiceEntry 11 }
prvtEpsServiceAdminFreeze OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used to freeze the state of the protection service."
::= { prvtEpsServiceEntry 12 }
prvtEpsServiceAdminStatus OBJECT-TYPE
SYNTAX INTEGER { up(1), down(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Administrative status of the protection service."
::= { prvtEpsServiceEntry 13 }
prvtEpsServiceActivePath OBJECT-TYPE
SYNTAX INTEGER { working(0), protection(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protected service active path."
::= { prvtEpsServiceEntry 14 }
prvtEpsServiceDefectsPresent OBJECT-TYPE
SYNTAX BITS { fullyIncompatibleProvisioning(0),
protectionSwitchingIncomplete(1),
protectionConfigurationMismatch(2),
epsConfigurationMismatch(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defects registered by the APS protocol could be either none or a composition of bits 0-3:
fullyIncompatibleProvisioning(0) - occurs upon reception of three APS frames with the
incompatible 'B' bit value within the 22.5 second period;
protectionSwitchingIncomplete(1) - occurs if the transmitted 'Requested Signal' and the
received 'Bridged Signal' do not match for a period of 50ms or longer;
protectionConfigurationMismatch(2) - working/protection configuration mismatch, occurs at
the reception of three APS frames from the working transport entity within the 22.5 second period;
epsConfigurationMismatch(3) - provisioning mismatch - for example, the local device is
set to revertive mode and the remote device is set to non-revertive mode."
::= { prvtEpsServiceEntry 15 }
prvtEpsServiceLocalState OBJECT-TYPE
SYNTAX PrvtEpsProtectionStateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protection state of the local side."
::= { prvtEpsServiceEntry 19 }
prvtEpsServiceOperationalStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies whether this service is ready for running.
The operational status can be up(true) or down(false).
When creating the service the operational
status will be down. Receiving CCMs from both transport
entities and establishment of APS on the protection transport
entity will bring the operational status to up."
::= { prvtEpsServiceEntry 20 }
prvtEpsServiceLastEvent OBJECT-TYPE
SYNTAX INTEGER { unknown(0), switchoverAlarm(1),
lostCommunication(2), restoredCommunication(3),
signalFailDetected(4), signalDegradeDetected(5),
protctSignalFailDetected(6), signalFailRecovery(7),
signalDegradeRecovery(8),
protctSignalFailRecovery(9) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The most recent event about which the application has sent a notification."
::= { prvtEpsServiceEntry 21 }
prvtEpsServicePrimaryStatus OBJECT-TYPE
SYNTAX INTEGER { psFailed(0), psOk(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Primary path state."
::= { prvtEpsServiceEntry 22 }
prvtEpsServiceSecondaryStatus OBJECT-TYPE
SYNTAX INTEGER { psFailed(0), psOk(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Secondary path state."
::= { prvtEpsServiceEntry 23 }
prvtEpsServiceRemoteState OBJECT-TYPE
SYNTAX PrvtEpsProtectionStateType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protection state of the remote side."
::= { prvtEpsServiceEntry 24 }
prvtEpsServiceRemoteApsChannel OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active APS communication reported by the remote."
::= { prvtEpsServiceEntry 25 }
prvtEpsServiceRemoteProtection OBJECT-TYPE
SYNTAX INTEGER { pt1Plus1(0), pt1To1(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of protection (1+1 or 1:1) reported by the remote device."
::= { prvtEpsServiceEntry 26 }
prvtEpsServiceRemoteDirection OBJECT-TYPE
SYNTAX INTEGER { dtUnidirectional(0), dtBidirectional(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of protection (unidirectional or bidirectional) reported by the remote."
::= { prvtEpsServiceEntry 27 }
prvtEpsServiceRemoteRevertive OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Protection type (revertive or non-revertive) reported by the remote."
::= { prvtEpsServiceEntry 28 }
prvtEpsServiceLocalApsChannel OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active APS communication reported by the remote."
::= { prvtEpsServiceEntry 29 }
prvtEpsServiceLocalProtection OBJECT-TYPE
SYNTAX INTEGER { pt1Plus1(0), pt1To1(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of protection (1+1 or 1:1) reported by the remote device."
::= { prvtEpsServiceEntry 30 }
prvtEpsServiceLocalDirection OBJECT-TYPE
SYNTAX INTEGER { dtUnidirectional(0), dtBidirectional(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of protection (unidirectional or bidirectional) reported by the remote."
::= { prvtEpsServiceEntry 31 }
prvtEpsServiceClear OBJECT-TYPE
SYNTAX PrvtEpsActionType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sends the Clear command to this EPS service."
::= { prvtEpsServiceEntry 32 }
prvtEpsServiceManualSwitch OBJECT-TYPE
SYNTAX PrvtEpsActionType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sends the Manual Switch command to this EPS service."
::= { prvtEpsServiceEntry 33 }
prvtEpsServiceForcedSwitch OBJECT-TYPE
SYNTAX PrvtEpsActionType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sends the Forced Switch command to this EPS service."
::= { prvtEpsServiceEntry 34 }
prvtEpsServiceLockout OBJECT-TYPE
SYNTAX PrvtEpsActionType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Sends the LockOut command to this EPS service."
::= { prvtEpsServiceEntry 35 }
prvtEpsServiceProtectionCounter OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts how many times the service has gone to Protection."
::= { prvtEpsServiceEntry 36 }
prvtEpsDefectAlarm NOTIFICATION-TYPE
OBJECTS { prvtEpsServiceOperationalStatus,
prvtEpsServiceDefectsPresent }
STATUS current
DESCRIPTION
"1. EPS service is either operational or not operational;
2. Failure of protocol defects."
::= { prvtEpsMIBNotifications 1 }
prvtEpsSwitchoverAlarm NOTIFICATION-TYPE
OBJECTS { prvtEpsServiceActivePath }
STATUS current
DESCRIPTION
"The alarm is issued if the active link is changed,
pointing to the path where the switchover occured."
::= { prvtEpsMIBNotifications 2 }
prvtEpsLostCommunication NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of non reception of APS frames
in three consecutive intervals each representing 5 seconds."
::= { prvtEpsMIBNotifications 3 }
prvtEpsRestoredCommunication NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"APS frames are received normally after APS communication failure."
::= { prvtEpsMIBNotifications 4 }
prvtEpsSignalFailDetected NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of CCMs are not received
and (3.5 * CCMtime(CCMinterval)) has expired."
::= { prvtEpsMIBNotifications 5 }
prvtEpsSignalDegradeDetected NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of monitored error threshold is crossed:
1W Jitter error,
2W Jitter error,
Latency error,
Frame loss error."
::= { prvtEpsMIBNotifications 6 }
prvtEpsProtctSignalFailDetected NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of CCMs are not received on the protected link
and (3.5 * CCMtime(CCMinterval)) has expired or the protected link is down."
::= { prvtEpsMIBNotifications 7 }
prvtEpsSignalFailRecovery NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of CCMs start to be received
correctly again after a prvtEpsSignalFailDetected alarm occured
and (3.5 * CCMtime(CCMinterval)) timer no longer expires or the link is up ."
::= { prvtEpsMIBNotifications 8 }
prvtEpsSignalDegradeRecovery NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of monitored error threshold is crossed bellow limis:
1W Jitter error,
2W Jitter error,
Latency error,
Frame loss error."
::= { prvtEpsMIBNotifications 9 }
prvtEpsProtctSignalFailRecovery NOTIFICATION-TYPE
OBJECTS { prvtEpsSvcId }
STATUS current
DESCRIPTION
"The alarm is issued in case of CCMs start to be received correctly again
on the protected link after a prvtEpsProtctSignalFailDetected alarm occured
and (3.5 * CCMtime(CCMinterval)) timer no longer expires or the link is up ."
::= { prvtEpsMIBNotifications 10 }
END -- end of module PRVT-EPS-MIB.