mibs/MIBS/telco-systems/binox/PRVT-STORM-CTL-MIB
2023-12-05 12:25:34 +01:00

169 lines
5.7 KiB
Plaintext

-- *********************************************************************
-- **
-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-STORM-CTL-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-STORM-CTL-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex
FROM IF-MIB
switch
FROM PRVT-SWITCH-MIB
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION, TruthValue
FROM SNMPv2-TC;
prvtStormCtlMIB MODULE-IDENTITY
LAST-UPDATED "201006210000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The MIB module for managing storm control."
REVISION "201006210000Z"
DESCRIPTION
"Initial version."
::= { switch 171 }
RateThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A rate threshold in packets per seconds."
SYNTAX Unsigned32
prvtStormCtlMIBObjects OBJECT IDENTIFIER
::= { prvtStormCtlMIB 1 }
prvtStrmCtlPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStrmCtlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interfaces that have storm control functionality configured."
::= { prvtStormCtlMIBObjects 1 }
prvtStrmCtlPortEntry OBJECT-TYPE
SYNTAX PrvtStrmCtlPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtStrmCtlPortTable."
INDEX { ifIndex }
::= { prvtStrmCtlPortTable 1 }
PrvtStrmCtlPortEntry ::= SEQUENCE {
prvtStrmCtlPortRowStatus RowStatus,
prvtStrmCtlPortShutdown TruthValue
}
prvtStrmCtlPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus for this port."
::= { prvtStrmCtlPortEntry 1 }
prvtStrmCtlPortShutdown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Set to 'false' to enable storm control functionality on this port."
::= { prvtStrmCtlPortEntry 3 }
prvtStrmCtlPortTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtStrmCtlPortTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of traffic-type specific configuration for each interface.
Currently, only one traffic type is supported per interface."
::= { prvtStormCtlMIBObjects 3 }
prvtStrmCtlPortTrafficEntry OBJECT-TYPE
SYNTAX PrvtStrmCtlPortTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtStrmCtlPortTrafficTable."
INDEX { ifIndex, prvtStrmCtlPortTrafficType }
::= { prvtStrmCtlPortTrafficTable 1 }
PrvtStrmCtlPortTrafficEntry ::= SEQUENCE {
prvtStrmCtlPortTrafficType INTEGER,
prvtStrmCtlPortTrafficRowStatus RowStatus,
prvtStrmCtlPortTrafficThreshold RateThresholdType
}
prvtStrmCtlPortTrafficType OBJECT-TYPE
SYNTAX INTEGER { all(0), unknown(1), multicast(2), broadcast(4) }
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The type of traffic to which this row applies "
::= { prvtStrmCtlPortTrafficEntry 1 }
prvtStrmCtlPortTrafficRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus for this traffic type."
::= { prvtStrmCtlPortTrafficEntry 2 }
prvtStrmCtlPortTrafficThreshold OBJECT-TYPE
SYNTAX RateThresholdType
UNITS "packets-per-second"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The threshold at which, when exceeded, traffic will undergo
storm control action for this port and traffic type."
::= { prvtStrmCtlPortTrafficEntry 3 }
END -- end of module PRVT-STORM-CTL-MIB.