-- ** BATM Advanced Communications.
|
|
-- **
|
|
-- *********************************************************************
|
|
-- ** Filename: PRVT-STORM-CTL-MIB.mib
|
|
-- ** Project: T-Metro Switches.
|
|
-- ** Purpose: Private MIB
|
|
-- *********************************************************************
|
|
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
|
|
-- WARNING:
|
|
--
|
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|
--
|
|
-- This file is the property of BATM Advanced Communications and contains
|
|
-- proprietary and confidential information. This file is made
|
|
-- available to authorized BATM customers on the express
|
|
-- condition that neither it, nor any of the information contained
|
|
-- therein, shall be disclosed to third parties or be used for any
|
|
-- purpose other than to replace, modify or upgrade firmware and/or
|
|
-- software components of BATM manufactured equipment within the
|
|
-- authorized customer's network, and that such transfer be
|
|
-- completed in accordance with the instructions provided by
|
|
-- BATM. Any other use is strictly prohibited.
|
|
--
|
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|
--
|
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
PRVT-STORM-CTL-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
ifIndex
|
|
FROM IF-MIB
|
|
switch
|
|
FROM PRVT-SWITCH-MIB
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
RowStatus, TEXTUAL-CONVENTION, TruthValue
|
|
FROM SNMPv2-TC;
|
|
|
|
prvtStormCtlMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201006210000Z"
|
|
ORGANIZATION
|
|
"BATM Advanced Communication"
|
|
CONTACT-INFO
|
|
"BATM/Telco Systems Support team
|
|
Email:
|
|
For North America: techsupport@telco.com
|
|
For North Europe: support@batm.de, info@batm.de
|
|
For the rest of the world: techsupport@telco.com"
|
|
DESCRIPTION
|
|
"The MIB module for managing storm control."
|
|
REVISION "201006210000Z"
|
|
DESCRIPTION
|
|
"Initial version."
|
|
::= { switch 171 }
|
|
|
|
|
|
RateThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A rate threshold in packets per seconds."
|
|
SYNTAX Unsigned32
|
|
|
|
prvtStormCtlMIBObjects OBJECT IDENTIFIER
|
|
::= { prvtStormCtlMIB 1 }
|
|
|
|
prvtStrmCtlPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtStrmCtlPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of interfaces that have storm control functionality configured."
|
|
::= { prvtStormCtlMIBObjects 1 }
|
|
|
|
prvtStrmCtlPortEntry OBJECT-TYPE
|
|
SYNTAX PrvtStrmCtlPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in prvtStrmCtlPortTable."
|
|
INDEX { ifIndex }
|
|
::= { prvtStrmCtlPortTable 1 }
|
|
|
|
PrvtStrmCtlPortEntry ::= SEQUENCE {
|
|
prvtStrmCtlPortRowStatus RowStatus,
|
|
prvtStrmCtlPortShutdown TruthValue
|
|
}
|
|
|
|
prvtStrmCtlPortRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RowStatus for this port."
|
|
::= { prvtStrmCtlPortEntry 1 }
|
|
|
|
prvtStrmCtlPortShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to 'false' to enable storm control functionality on this port."
|
|
::= { prvtStrmCtlPortEntry 3 }
|
|
|
|
prvtStrmCtlPortTrafficTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtStrmCtlPortTrafficEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of traffic-type specific configuration for each interface.
|
|
Currently, only one traffic type is supported per interface."
|
|
::= { prvtStormCtlMIBObjects 3 }
|
|
|
|
prvtStrmCtlPortTrafficEntry OBJECT-TYPE
|
|
SYNTAX PrvtStrmCtlPortTrafficEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in prvtStrmCtlPortTrafficTable."
|
|
INDEX { ifIndex, prvtStrmCtlPortTrafficType }
|
|
::= { prvtStrmCtlPortTrafficTable 1 }
|
|
|
|
PrvtStrmCtlPortTrafficEntry ::= SEQUENCE {
|
|
prvtStrmCtlPortTrafficType INTEGER,
|
|
prvtStrmCtlPortTrafficRowStatus RowStatus,
|
|
prvtStrmCtlPortTrafficThreshold RateThresholdType
|
|
}
|
|
|
|
prvtStrmCtlPortTrafficType OBJECT-TYPE
|
|
SYNTAX INTEGER { all(0), unknown(1), multicast(2), broadcast(4) }
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of traffic to which this row applies "
|
|
::= { prvtStrmCtlPortTrafficEntry 1 }
|
|
|
|
prvtStrmCtlPortTrafficRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RowStatus for this traffic type."
|
|
::= { prvtStrmCtlPortTrafficEntry 2 }
|
|
|
|
prvtStrmCtlPortTrafficThreshold OBJECT-TYPE
|
|
SYNTAX RateThresholdType
|
|
UNITS "packets-per-second"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The threshold at which, when exceeded, traffic will undergo
|
|
storm control action for this port and traffic type."
|
|
::= { prvtStrmCtlPortTrafficEntry 3 }
|
|
|
|
END -- end of module PRVT-STORM-CTL-MIB.
|