-- ** BATM Advanced Communications.
-- **
-- *********************************************************************
-- ** Filename: PRVT-TE-PARAM-MIB.mib
-- ** Project: T-Metro Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications and contains
-- proprietary and confidential information. This file is made
-- available to authorized BATM customers on the express
-- condition that neither it, nor any of the information contained
-- therein, shall be disclosed to third parties or be used for any
-- purpose other than to replace, modify or upgrade firmware and/or
-- software components of BATM manufactured equipment within the
-- authorized customer's network, and that such transfer be
-- completed in accordance with the instructions provided by
-- BATM. Any other use is strictly prohibited.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
--
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
--
-- ----------------------------------------------------------------------------
PRVT-TE-PARAM-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex
FROM IF-MIB
mpls
FROM PRVT-SWITCH-MIB
Integer32, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
FROM SNMPv2-SMI
RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
prvtTeParamMIB MODULE-IDENTITY
LAST-UPDATED "201004280000Z"
ORGANIZATION
"BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"The MIB module for management of TE-params entities."
REVISION "201004280000Z"
DESCRIPTION
"initial version"
::= { mpls 9 }
PrvtTeLinkBandwidthSpeed ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Used in combination with PrvtTeLinkBandwidthUnits to specify a link's bandwidth."
SYNTAX Unsigned32
PrvtTeLinkBandwidthUnits ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Used in combination with PrvtTeLinkBandwidthSpeed to specify a link's bandwidth."
SYNTAX INTEGER { bps(0), kbps(1), mbps(2), gbps(3) }
prvtTeParamMIBObjects OBJECT IDENTIFIER
::= { prvtTeParamMIB 1 }
prvtTeParamLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtTeParamLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table specifying the parameters of TE links."
::= { prvtTeParamMIBObjects 2 }
prvtTeParamLinkEntry OBJECT-TYPE
SYNTAX PrvtTeParamLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtTeParamLinkTable."
INDEX { ifIndex }
::= { prvtTeParamLinkTable 1 }
PrvtTeParamLinkEntry ::= SEQUENCE {
prvtTeParamLinkRowStatus RowStatus,
prvtTeParamLinkMetric Unsigned32,
prvtTeParamLinkPhyBandwidthSpeed PrvtTeLinkBandwidthSpeed,
prvtTeParamLinkPhyBandwidthUnits PrvtTeLinkBandwidthUnits,
prvtTeParamLinkMaxRsvBwSpeed PrvtTeLinkBandwidthSpeed,
prvtTeParamLinkMaxRsvBwUnits PrvtTeLinkBandwidthUnits
}
prvtTeParamLinkRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus entry for theprvtTeParamLinkTable."
::= { prvtTeParamLinkEntry 1 }
prvtTeParamLinkMetric OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Traffic engineering metric (TEM) for the TE link.
The TEM is derived from its component links.
All component links within the TE link must have the same TEM."
REFERENCE
"Link Bundling in MPLS Traffic Engineering (TE), RFC 4201"
::= { prvtTeParamLinkEntry 2 }
prvtTeParamLinkPhyBandwidthSpeed OBJECT-TYPE
SYNTAX PrvtTeLinkBandwidthSpeed
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used together with the prvtTeParamLinkPhyBandwidthUnits
object to specify the physical bandwidth for the TE link."
::= { prvtTeParamLinkEntry 3 }
prvtTeParamLinkPhyBandwidthUnits OBJECT-TYPE
SYNTAX PrvtTeLinkBandwidthUnits
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used together with the prvtTeParamLinkPhyBandwidthSpeed
object to specify the physical bandwidth for the TE link."
::= { prvtTeParamLinkEntry 4 }
prvtTeParamLinkMaxRsvBwSpeed OBJECT-TYPE
SYNTAX PrvtTeLinkBandwidthSpeed
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used together with the prvtTeParamLinkMaxRsvBwUnits
object to specify the maximum bandwidth for the TE link."
::= { prvtTeParamLinkEntry 5 }
prvtTeParamLinkMaxRsvBwUnits OBJECT-TYPE
SYNTAX PrvtTeLinkBandwidthUnits
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Used together with the prvtTeParamLinkMaxRsvBwSpeed
object to specify the maximum bandwidth that can be reserved for the TE link."
::= { prvtTeParamLinkEntry 6 }
prvtTeParamLinkAdminGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtTeParamLinkAdminGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table specifying the administrative groups to which a TE link belongs."
::= { prvtTeParamMIBObjects 3 }
prvtTeParamLinkAdminGrpEntry OBJECT-TYPE
SYNTAX PrvtTeParamLinkAdminGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in prvtTeParamLinkAdminGrpTable."
INDEX { ifIndex, prvtTeParamLinkAdminGrpId }
::= { prvtTeParamLinkAdminGrpTable 1 }
PrvtTeParamLinkAdminGrpEntry ::= SEQUENCE {
prvtTeParamLinkAdminGrpId Integer32,
prvtTeParamLinkAdminGrpRowStatus RowStatus
}
prvtTeParamLinkAdminGrpId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ID of the administrative group to which the TE link belongs."
::= { prvtTeParamLinkAdminGrpEntry 1 }
prvtTeParamLinkAdminGrpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus entry for the prvtTeParamLinkAdminGrpTable."
::= { prvtTeParamLinkAdminGrpEntry 2 }
prvtTeParamAdminGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrvtTeParamAdminGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table storing the identifiers for an administrative group."
::= { prvtTeParamMIBObjects 5 }
prvtTeParamAdminGroupEntry OBJECT-TYPE
SYNTAX PrvtTeParamAdminGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"prvtTeParamAdminGroupTable allows the specifying of a group-name to
each administrative group. Each group is uniquely identified by its
prvtTeParamAdminGroupId."
INDEX { prvtTeParamAdminGroupId }
::= { prvtTeParamAdminGroupTable 1 }
PrvtTeParamAdminGroupEntry ::= SEQUENCE {
prvtTeParamAdminGroupId Integer32,
prvtTeParamAdminGroupRowStatus RowStatus,
prvtTeParamAdminGroupName OCTET STRING
}
prvtTeParamAdminGroupId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ID uniquely identifying an administrative group."
::= { prvtTeParamAdminGroupEntry 1 }
prvtTeParamAdminGroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The RowStatus entry for theprvtTeParamAdminGroupTable."
::= { prvtTeParamAdminGroupEntry 2 }
prvtTeParamAdminGroupName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..15))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of the administrative group."
::= { prvtTeParamAdminGroupEntry 3 }
END -- end of module PRVT-TE-PARAM-MIB.