TPLINK-SYSINFO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
tplinkMgmt
|
|
FROM TPLINK-MIB
|
|
ifIndex
|
|
FROM RFC1213-MIB;
|
|
|
|
tplinkSysInfoMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201211290000Z"
|
|
ORGANIZATION "TP-LINK"
|
|
CONTACT-INFO "www.tplink.com"
|
|
DESCRIPTION
|
|
"This MIB module contain a collection of managed objects
|
|
that get infomation of the system."
|
|
|
|
REVISION "201211290000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { tplinkMgmt 1 }
|
|
|
|
tplinkSysInfoMIBObjects OBJECT IDENTIFIER ::= {tplinkSysInfoMIB 1}
|
|
tplinkSysInfoNotifications OBJECT IDENTIFIER ::= {tplinkSysInfoMIB 2}
|
|
|
|
|
|
tpSysInfoDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual description of the entity. This value
|
|
should include the full name and version
|
|
identification of the system's hardware type,
|
|
software operating-system, and networking
|
|
software. It is current that this only contain
|
|
printable ASCII characters."
|
|
::= { tplinkSysInfoMIBObjects 1 }
|
|
|
|
tpSysInfoHostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An administratively-assigned name for this
|
|
managed node. By convention, this is the node's
|
|
fully-qualified domain name.range:17 byte."
|
|
::= { tplinkSysInfoMIBObjects 2 }
|
|
|
|
tpSysInfoLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical location of this node (e.g.,
|
|
`telephone closet, 3rd floor'),range:32 byte."
|
|
::= { tplinkSysInfoMIBObjects 3 }
|
|
|
|
tpSysInfoContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The textual identification of the contact person
|
|
for this managed node, together with information
|
|
on how to contact this person.range:32 byte."
|
|
::= { tplinkSysInfoMIBObjects 4 }
|
|
|
|
tpSysInfoHwVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardWare version of the product."
|
|
::= { tplinkSysInfoMIBObjects 5 }
|
|
|
|
tpSysInfoSwVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The softWare version of the product."
|
|
::= { tplinkSysInfoMIBObjects 6 }
|
|
|
|
tpSysInfoMacAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address of the product."
|
|
::= { tplinkSysInfoMIBObjects 7 }
|
|
|
|
tpSysInfoSerialNum OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Serial number of the product."
|
|
::= { tplinkSysInfoMIBObjects 8 }
|
|
|
|
tpSysInfoUpTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in hundredths of a second) since the
|
|
network management portion of the system was last
|
|
re-initialized."
|
|
::= { tplinkSysInfoMIBObjects 9 }
|
|
|
|
tpSysInfoSerialPort OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
9600(0), --config the baud rate as 9600
|
|
19200(1), --config the baud rate as 19200
|
|
38400(2), --config the baud rate as 38400
|
|
57600(3), --config the baud rate as 57600
|
|
115200(4) --config the baud rate as 115200
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"config the baud rate of the system"
|
|
::= { tplinkSysInfoMIBObjects 10}
|
|
|
|
tpSysInfoPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TPSYSINFOPORTENTRY
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Utilization."
|
|
::= { tplinkSysInfoMIBObjects 11 }
|
|
|
|
tpSysInfoPortEntry OBJECT-TYPE
|
|
SYNTAX TPSYSINFOPORTENTRY
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry contains of the information of port Utilization."
|
|
INDEX { ifIndex }
|
|
::= { tpSysInfoPortTable 1 }
|
|
|
|
TPSYSINFOPORTENTRY ::=
|
|
SEQUENCE {
|
|
tpSysInfoPortRxUtilization
|
|
OCTET STRING,
|
|
tpSysInfoPortTxUtilization
|
|
OCTET STRING
|
|
}
|
|
|
|
tpSysInfoPortRxUtilization OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the port Tx Utilization."
|
|
::= { tpSysInfoPortEntry 1 }
|
|
|
|
tpSysInfoPortTxUtilization OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the port Tx Utilization."
|
|
::= { tpSysInfoPortEntry 2 }
|
|
|
|
tpSysInfoLed OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
off(0), --LED off
|
|
on(1), --LED on
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config the switch LED status."
|
|
::= { tplinkSysInfoMIBObjects 12}
|
|
|
|
END |