mibs/MIBS/transition/TN-ETHSOAM-PM-MIB
2023-12-05 12:25:34 +01:00

1485 lines
53 KiB
Plaintext

-- *****************************************************************
-- TN-ETHSOAM-PM-MIB.my : TN Ethernet OAM MIB
--
-- Author : Angela Xing & Tony Lei
--
-- Copyright (c) 2009 by Transition Networks, Inc.
-- All rights reserved.
--
-- *************************************************************************************************
--
TN-ETHSOAM-PM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Counter64, Unsigned32
FROM SNMPv2-SMI
DateAndTime, TimeInterval, RowStatus
FROM SNMPv2-TC
tnEthSoaminstance
FROM TN-ETHSOAM-MIB
tnEvcIndex, tnEvcEceId
FROM TN-EVC-MIB
ifIndex
FROM IF-MIB
tnProducts
FROM TRANSITION-SMI;
--
-- main body
--
tnEthSoamPmMIB MODULE-IDENTITY
LAST-UPDATED "201403281200Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com
"
DESCRIPTION
"This MIB module contains the Performance Monitoring objects for
the management of Ethernet Services Operations, Administration
and Maintenance in TN platform products."
REVISION "201403281200Z"
DESCRIPTION
"Initial version of this MIB module."
::= { tnProducts 143 }
-- 1.3.6.1.4.1.868.2.5.143.0
tnEthSoamPmNotifications OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 0 }
-- 1.3.6.1.4.1.868.2.5.143.1
tnEthSoamPmCfgMIBObjects OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 1 }
-- 1.3.6.1.4.1.868.2.5.143.2
tnEthSoamPmStatsMIBObjects OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 2 }
-- 1.3.6.1.4.1.868.2.5.143.3
tnEthSoamPmNotificationMIBObjects OBJECT IDENTIFIER ::= { tnEthSoamPmMIB 3 }
--
-- sub Objects list
--
tnEthSoamPmSessionCfgObjects OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 1 }
tnEthSoamPmTransferCfgObjects OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 2 }
-- tnEthSoamPmThresholdCfgObjects OBJECT IDENTIFIER ::= { tnEthSoamPmCfgMIBObjects 3 }
tnEthSoamPmLmStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 1 }
tnEthSoamPmDmStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 2 }
tnEthSoamPmEvcStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 3 }
tnEthSoamPmEceStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 4 }
-- tnEthSoamPmPortStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 5 }
-- tnEthSoamPmThresholdStatsObjects OBJECT IDENTIFIER ::= { tnEthSoamPmStatsMIBObjects 6 }
-- 1.3.6.1.4.1.868.2.5.143.3.1
-- tnEthSoamPmThresholdCrossingNotifObj OBJECT IDENTIFIER ::= { tnEthSoamPmNotificationMIBObjects 1 }
-- ******************************************************************
-- TN Ethernet Performance Measurement Session Configuration Table
-- ******************************************************************
tnEthSoamPmSessionCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmSessionCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table configure the Performance monitor session and storage settings.
"
::= { tnEthSoamPmSessionCfgObjects 1 }
tnEthSoamPmSessionCfgEntry OBJECT-TYPE
SYNTAX TnEthSoamPmSessionCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries in this table configure the Performance monitor session and storage settings.
"
INDEX { tnEthSoamPmSessionCfgId }
::= { tnEthSoamPmSessionCfgTable 1 }
TnEthSoamPmSessionCfgEntry ::=
SEQUENCE {
tnEthSoamPmSessionCfgId Integer32,
tnEthSoamPmSessionCfgType INTEGER,
tnEthSoamPmSessionCfgSessionMode INTEGER,
tnEthSoamPmSessionCfgStorageMode INTEGER,
tnEthSoamPmSessionCfgInterval Unsigned32
}
tnEthSoamPmSessionCfgId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index to the Performce Monitor Configuration table which indicates
the specific session to be configured.
"
::= { tnEthSoamPmSessionCfgEntry 1 }
tnEthSoamPmSessionCfgType OBJECT-TYPE
SYNTAX INTEGER {
lossMeasurement(1),
delayMeasurement(2),
evc(3),
ece(4),
dmBinning(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Perfmonce Monitor session type:
- lossMeasurement SOAM PM loss measurement collect and storage.
- delayMeasurement SOAM PM delay measurement collect and storage.
- evc EVC Port based counters collect and storage.
- ece ECE Port based counters collect and storage.
- port Port based counters collect and storage.
"
::= { tnEthSoamPmSessionCfgEntry 2 }
tnEthSoamPmSessionCfgSessionMode OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable this performance monitor session.
"
::= { tnEthSoamPmSessionCfgEntry 3 }
tnEthSoamPmSessionCfgStorageMode OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable the performance monitor local storage.
"
::= { tnEthSoamPmSessionCfgEntry 4 }
tnEthSoamPmSessionCfgInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The measurement interval for the performance monitor.
The interval unit is minute, the valid range is system defined.
A typical range would be 1 - 60(mins)
"
::= { tnEthSoamPmSessionCfgEntry 5 }
-- ******************************************************************
-- TN Ethernet Performance Measurement Transfer Configuration Table
-- ******************************************************************
tnEthSoamPmTransferCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmTransferCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table configure the Performance Monitor data transfer related settings.
"
::= { tnEthSoamPmTransferCfgObjects 1 }
tnEthSoamPmTransferCfgEntry OBJECT-TYPE
SYNTAX TnEthSoamPmTransferCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in this table configure the Performance Monitor data transfer related settings.
"
INDEX { tnEthSoamPmTransferCfgId }
::= { tnEthSoamPmTransferCfgTable 1 }
TnEthSoamPmTransferCfgEntry ::=
SEQUENCE {
tnEthSoamPmTransferCfgId Integer32,
tnEthSoamPmTransferCfgMode INTEGER,
tnEthSoamPmTransferCfgSchedHrs BITS,
tnEthSoamPmTransferCfgSchedMins BITS,
tnEthSoamPmTransferCfgSchedOffset Integer32,
tnEthSoamPmTransferCfgRandomOffset Integer32,
tnEthSoamPmTransferCfgServerAddr OCTET STRING,
tnEthSoamPmTransferCfgIntervalMode INTEGER,
tnEthSoamPmTransferCfgIntervalNum Integer32,
tnEthSoamPmTransferCfgIncludeIncomplete INTEGER
}
tnEthSoamPmTransferCfgId OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicate the performance monitor data transfer table index.
"
::= { tnEthSoamPmTransferCfgEntry 1 }
tnEthSoamPmTransferCfgMode OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configure the performance monitor transfer mode per system. Possible modes are:
- Enabled: Transfer data is enabled.
- Disabled: Transfer data is disabled.
"
::= { tnEthSoamPmTransferCfgEntry 2 }
tnEthSoamPmTransferCfgSchedHrs OBJECT-TYPE
SYNTAX BITS {
hrs00(0),
hrs01(1),
hrs02(2),
hrs03(3),
hrs04(4),
hrs05(5),
hrs06(6),
hrs07(7),
hrs08(8),
hrs09(9),
hrs10(10),
hrs11(11),
hrs12(12),
hrs13(13),
hrs14(14),
hrs15(15),
hrs16(16),
hrs17(17),
hrs18(18),
hrs19(19),
hrs20(20),
hrs21(21),
hrs22(22),
hrs23(23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It must be possible to select one or more of the 24 hours in a day, when PM data transfer will happen.
00:00
01:00
02:00
03:00
04:00
05:00
06:00
07:00
08:00
09:00
10:00
11:00
12:00
13:00
14:00
15:00
16:00
17:00
18:00
19:00
20:00
21:00
22:00
23:00
Default is none selected.
"
::= { tnEthSoamPmTransferCfgEntry 3 }
tnEthSoamPmTransferCfgSchedMins OBJECT-TYPE
SYNTAX BITS {
mins00(0),
mins15(1),
mins30(2),
mins45(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It must be possible to select one or more of the four 15 min. in an hour, when PM data transfer will happen.
00:00
00:15
00:30
00:45
Default is none selected.
"
::= { tnEthSoamPmTransferCfgEntry 4 }
tnEthSoamPmTransferCfgSchedOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It must be possible to configure a fixed offset that is added to the scheduled transfer time.
The rage is 0-15 minutes. Default is 0 min.
The sum of Scheduled Fixed Offset and Scheduled Random Offset must not exceed 15 min.
"
::= { tnEthSoamPmTransferCfgEntry 5 }
tnEthSoamPmTransferCfgRandomOffset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It must be possible to configure a random offset that is added to the scheduled transfer time.
The offset added to the scheduled transfer time must be a random value in the range 0-Scheduled Offset.
The range is 0-900 seconds. Default is 0 sec.
The sum of Scheduled Offset and Random Offset must not exceed 15 min.
"
::= { tnEthSoamPmTransferCfgEntry 6 }
tnEthSoamPmTransferCfgServerAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..63))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It must be possible to configure the full URL of the server and the
corresponding directory (if any) for uploading.
The supported protocols are HTTP and TFTP.
To enable HTTP by entering http:// followed by the domain name or IP address.
To enable TFTP by entering tftp:// followed by the domain name or IP address.
The format is:
protocol://host_address:port_num/folder_name
while port_num and folder_name are optional.
For example, 'tftp://192.251.1.1:55/' will upload the counter files to
the tftp root directory in 192.251.1.1 at port 55 via tftp.
"
::= { tnEthSoamPmTransferCfgEntry 7 }
tnEthSoamPmTransferCfgIntervalMode OBJECT-TYPE
SYNTAX INTEGER {
allAvailableIntervals(1),
newIntervalsSinceLastTransfer(2),
fixedNumberOfIntervals(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"There are three supported interval modes.
All available intervals: To enable transfer of all completed Measurement Intervals.
New intervals since last transfer: To enable transfer of only completed Measurement Intervals since last transfer.
Fixed number of intervals: To enable transfer of all completed Measurement Intervals up to the configured number.
"
::= { tnEthSoamPmTransferCfgEntry 8 }
tnEthSoamPmTransferCfgIntervalNum OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" When Fixed number of interval selected, this value is used to determine the number of intervals to send.
The range is 1 to 96 Intervals.
"
::= { tnEthSoamPmTransferCfgEntry 9 }
tnEthSoamPmTransferCfgIncludeIncomplete OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this option is checked, PM data transfer will include the suspended (incomplete) transmission.
- Enabled: PM data transfer will include the suspended (incomplete) transmission.
- Disabled: PM data transfer will not include the suspended (incomplete) transmission.
"
::= { tnEthSoamPmTransferCfgEntry 10 }
-- ******************************************************************
-- TN Ethernet Loss Measurement History Statistic Table
-- ******************************************************************
tnEthSoamPmLmHistoryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmLmHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for availability history Measurement
Intervals in a SOAM Loss Measurement session.
Rows of this table object are created automatically
by the SNMP Agent when the Loss Measurement session is running and a
Measurement Interval is completed.
Each row in the table represents the history statistics for a Loss
Measurement session availability Measurement Interval for the defined
MEP.
32 completed Measurement Intervals are to be supported. If
there are at least 32 rows in the table and a new Measurement Interval
completes and a new row is to be added to the table, the oldest completed
Measurement Interval is deleted (row deletion).
The rows and objects in this table are to be persistent upon reboot
or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
for tnEthSoamPmSessionCfgType of 'lossMeasurement'.
"
::= { tnEthSoamPmLmStatsObjects 1 }
tnEthSoamPmLmHistoryStatsEntry OBJECT-TYPE
SYNTAX TnEthSoamPmLmHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of tnEthSoamPmLmHistoryStatsTable"
INDEX { tnEthSoamPmLmHistoryStatsIndex, tnEthSoaminstance }
::= { tnEthSoamPmLmHistoryStatsTable 1 }
TnEthSoamPmLmHistoryStatsEntry ::= SEQUENCE {
tnEthSoamPmLmHistoryStatsIndex Unsigned32,
tnEthSoamPmLmHistoryStatsEndTime DateAndTime,
tnEthSoamPmLmHistoryStatsElapsedTime TimeInterval,
tnEthSoamPmLmHistoryStatsTxCount Counter64,
tnEthSoamPmLmHistoryStatsRxCount Counter64,
tnEthSoamPmLmHistoryStatsNELossCount Counter64,
tnEthSoamPmLmHistoryStatsFELossCount Counter64,
tnEthSoamPmLmHistoryStatsNEAvgFlr Unsigned32,
tnEthSoamPmLmHistoryStatsFEAvgFlr Unsigned32
}
tnEthSoamPmLmHistoryStatsIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for the Measurement Interval within this PM session.
Measurement Interval indexes are assigned sequentially by
the device. The first Measurement Interval that occurs after
the session is started is assigned index 1.
Referential integrity is necessary, i.e., the index needs to be
persistent upon a reboot or restart of a device. The index
is never reused while this session is active until it wraps to zero.
The index value keeps increasing up to that time.
"
::= { tnEthSoamPmLmHistoryStatsEntry 1 }
tnEthSoamPmLmHistoryStatsEndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval ended.
"
::= { tnEthSoamPmLmHistoryStatsEntry 2 }
tnEthSoamPmLmHistoryStatsElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval has been running, in 0.01
seconds.
"
::= { tnEthSoamPmLmHistoryStatsEntry 3 }
tnEthSoamPmLmHistoryStatsTxCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames
in this MEP for this Measurement Interval.
"
::= { tnEthSoamPmLmHistoryStatsEntry 4 }
tnEthSoamPmLmHistoryStatsRxCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames
in this MEP for this Measurement Interval.
"
::= { tnEthSoamPmLmHistoryStatsEntry 5 }
tnEthSoamPmLmHistoryStatsNELossCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of frames lossed in the
near end of this MEP for this Measurement Interval.
"
::= { tnEthSoamPmLmHistoryStatsEntry 6 }
tnEthSoamPmLmHistoryStatsFELossCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of frames lossed in the
far end of this MEP for this Measurement Interval.
"
::= { tnEthSoamPmLmHistoryStatsEntry 7 }
tnEthSoamPmLmHistoryStatsNEAvgFlr OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average frame loss ratio in the
near end of this MEP calculated for this Measurement Interval.
The value is a ratio that is expressed as a
percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1 indicates 0.001 percent.
"
::= { tnEthSoamPmLmHistoryStatsEntry 8 }
tnEthSoamPmLmHistoryStatsFEAvgFlr OBJECT-TYPE
SYNTAX Unsigned32 (0..100000)
UNITS "milli-percent"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average frame loss ratio in the
far end of this MEP calculated for this Measurement Interval.
The value is a ratio that is expressed as a
percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00).
Units are in milli-percent, where 1 indicates 0.001 percent.
"
::= { tnEthSoamPmLmHistoryStatsEntry 9 }
-- ******************************************************************
-- TN Ethernet Delay Measurement History Statistic Table
-- ******************************************************************
tnEthSoamPmDmHistoryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmDmHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for history Measurement
Intervals in a SOAM Delay Measurement session.
Rows of this table are created automatically
by the SNMP Agent when the Delay Measurement session is running and a
Measurement Interval is completed.
Each row in the table represents the Measurement Interval history
statistics for a Delay Measurement session for the defined MEP.
Each row in the table represents the history statistics for a delay
Measurement session availability Measurement Interval for the defined
MEP.
32 completed Measurement Intervals are to be supported. If
there are at least 32 rows in the table and a new Measurement Interval
completes and a new row is to be added to the table, the oldest completed
Measurement Interval is deleted (row deletion).
The rows and objects in this table are to be persistent upon reboot
or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
for tnEthSoamPmSessionCfgType of 'delayMeasurement'.
"
::= { tnEthSoamPmDmStatsObjects 1 }
tnEthSoamPmDmHistoryStatsEntry OBJECT-TYPE
SYNTAX TnEthSoamPmDmHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of tnEthSoamPmDmHistoryStatsTable"
INDEX { tnEthSoamPmDmHistoryStatsIndex, tnEthSoaminstance }
::= { tnEthSoamPmDmHistoryStatsTable 1 }
TnEthSoamPmDmHistoryStatsEntry ::= SEQUENCE {
tnEthSoamPmDmHistoryStatsIndex Unsigned32,
tnEthSoamPmDmHistoryStatsEndTime DateAndTime,
tnEthSoamPmDmHistoryStatsElapsedTime TimeInterval,
tnEthSoamPmDmHistoryStatsTxCount Counter64,
tnEthSoamPmDmHistoryStatsRxCount Counter64,
tnEthSoamPmDmHistoryStatsFNAvgFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsFNAvgFrameDV Unsigned32,
tnEthSoamPmDmHistoryStatsFNMinFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsFNMaxFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsNFAvgFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsNFAvgFrameDV Unsigned32,
tnEthSoamPmDmHistoryStatsNFMinFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsNFMaxFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDV Unsigned32,
tnEthSoamPmDmHistoryStatsTwoWayMinFrameDelay Unsigned32,
tnEthSoamPmDmHistoryStatsTwoWayMaxFrameDelay Unsigned32
}
tnEthSoamPmDmHistoryStatsIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for the Measurement Interval within this PM session.
Measurement Interval indexes are assigned sequentially by
the device. The first Measurement Interval that occurs after
the session is started is assigned index 1.
Referential integrity is necessary, i.e., the index needs to be
persistent upon a reboot or restart of a device. The index
is never reused while this session is active until it wraps to zero.
The index value keeps increasing up to that time.
"
::= { tnEthSoamPmDmHistoryStatsEntry 1 }
tnEthSoamPmDmHistoryStatsEndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval ended.
"
::= { tnEthSoamPmDmHistoryStatsEntry 2 }
tnEthSoamPmDmHistoryStatsElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval has been running, in 0.01
seconds.
"
::= { tnEthSoamPmDmHistoryStatsEntry 3 }
tnEthSoamPmDmHistoryStatsTxCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of frames transmitted
in this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 4 }
tnEthSoamPmDmHistoryStatsRxCount OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of frames received
in this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 5 }
tnEthSoamPmDmHistoryStatsFNAvgFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average one-way frame delay
in the far end to near end direction calculated by this MEP
for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 6 }
tnEthSoamPmDmHistoryStatsFNAvgFrameDV OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average one-way inter-frame delay
interval in the far end to near end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 7 }
tnEthSoamPmDmHistoryStatsFNMinFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the minimum one-way inter-frame delay
interval in the far end to near end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 8 }
tnEthSoamPmDmHistoryStatsFNMaxFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the maximum one-way inter-frame delay
interval in the far end to near end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 9 }
tnEthSoamPmDmHistoryStatsNFAvgFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average one-way frame delay
in the near end to far end direction calculated by this MEP
for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 10 }
tnEthSoamPmDmHistoryStatsNFAvgFrameDV OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average one-way inter-frame delay
interval in the near end to far end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 11 }
tnEthSoamPmDmHistoryStatsNFMinFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the minimum one-way inter-frame delay
interval in the near end to far end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 12 }
tnEthSoamPmDmHistoryStatsNFMaxFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the maximum one-way inter-frame delay
interval in the near end to far end direction calculated by
this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 13 }
tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average two-way inter-frame delay
interval direction calculated by this MEP for this
Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 14 }
tnEthSoamPmDmHistoryStatsTwoWayAvgFrameDV OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the average two-way inter-frame delay
interval calculated by this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 15 }
tnEthSoamPmDmHistoryStatsTwoWayMinFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the minimum two-way inter-frame delay
interval calculated by this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 16 }
tnEthSoamPmDmHistoryStatsTwoWayMaxFrameDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the maximum two-way inter-frame delay
interval calculated by this MEP for this Measurement Interval.
"
::= { tnEthSoamPmDmHistoryStatsEntry 17 }
-- ******************************************************************
-- TN Ethernet EVC History Statistic Table
-- ******************************************************************
tnEthSoamPmEvcHistoryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmEvcHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for history Measurement
Intervals in a SOAM EVC Measurement session.
Rows of this table object are created automatically
by the SNMP Agent when the EVC Measurement session is running and a
Measurement Interval is completed.
Each row in the table represents the history statistics for a EVC
Measurement session availability Measurement Interval for the defined
EVC.
32 completed Measurement Intervals are to be supported. If
there are at least 32 rows in the table and a new Measurement Interval
completes and a new row is to be added to the table, the oldest completed
Measurement Interval is deleted (row deletion).
The rows and objects in this table are to be persistent upon reboot
or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
for tnEthSoamPmSessionCfgType of 'evc'.
"
::= { tnEthSoamPmEvcStatsObjects 1 }
tnEthSoamPmEvcHistoryStatsEntry OBJECT-TYPE
SYNTAX TnEthSoamPmEvcHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of tnEthSoamPmEvcHistoryStatsTable"
INDEX { tnEthSoamPmEvcHistoryStatsIndex, tnEvcIndex, ifIndex }
::= { tnEthSoamPmEvcHistoryStatsTable 1 }
TnEthSoamPmEvcHistoryStatsEntry ::= SEQUENCE {
tnEthSoamPmEvcHistoryStatsIndex Unsigned32,
tnEthSoamPmEvcHistoryStatsEndTime DateAndTime,
tnEthSoamPmEvcHistoryStatsElapsedTime TimeInterval,
tnEthSoamPmEvcHistoryStatsGreenFramesTx Counter64,
tnEthSoamPmEvcHistoryStatsGreenFramesRx Counter64,
tnEthSoamPmEvcHistoryStatsGreenBytesTx Counter64,
tnEthSoamPmEvcHistoryStatsGreenBytesRx Counter64,
tnEthSoamPmEvcHistoryStatsYellowFramesTx Counter64,
tnEthSoamPmEvcHistoryStatsYellowFramesRx Counter64,
tnEthSoamPmEvcHistoryStatsYellowBytesTx Counter64,
tnEthSoamPmEvcHistoryStatsYellowBytesRx Counter64,
tnEthSoamPmEvcHistoryStatsRedFramesRx Counter64,
tnEthSoamPmEvcHistoryStatsRedBytesRx Counter64,
tnEthSoamPmEvcHistoryStatsDiscardFramesTx Counter64,
tnEthSoamPmEvcHistoryStatsDiscardFramesRx Counter64,
tnEthSoamPmEvcHistoryStatsDiscardBytesTx Counter64,
tnEthSoamPmEvcHistoryStatsDiscardBytesRx Counter64
}
tnEthSoamPmEvcHistoryStatsIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for the Measurement Interval within this PM session.
Measurement Interval indexes are assigned sequentially by
the device. The first Measurement Interval that occurs after
the session is started is assigned index 1.
Referential integrity is necessary, i.e., the index needs to be
persistent upon a reboot or restart of a device. The index
is never reused while this session is active until it wraps to zero.
The index value keeps increasing up to that time.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 1 }
tnEthSoamPmEvcHistoryStatsEndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval ended.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 2 }
tnEthSoamPmEvcHistoryStatsElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval has been running, in 0.01
seconds.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 3 }
tnEthSoamPmEvcHistoryStatsGreenFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames within
the CIR / CBS compliance level in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 4 }
tnEthSoamPmEvcHistoryStatsGreenFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames within
the CIR / CBS compliance level in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 5 }
tnEthSoamPmEvcHistoryStatsGreenBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes, where
frames are within the CIR / CBS compliance level in this
EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 6 }
tnEthSoamPmEvcHistoryStatsGreenBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames are within the CIR / CBS compliance level in this
EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 7 }
tnEthSoamPmEvcHistoryStatsYellowFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames exceeding
the CIR/CBS but within the EIR/EBS in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 8 }
tnEthSoamPmEvcHistoryStatsYellowFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames exceeding
the CIR/CBS but within the EIR/EBS in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 9 }
tnEthSoamPmEvcHistoryStatsYellowBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes, where
frames exceed the CIR/CBS but are within the EIR/EBS
in this EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 10 }
tnEthSoamPmEvcHistoryStatsYellowBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames exceed the CIR/CBS but are within the EIR/EBS
in this EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 11 }
tnEthSoamPmEvcHistoryStatsRedFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames
not conforming to either the CIR/CBS or the EIR/EBS
in this EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 12 }
tnEthSoamPmEvcHistoryStatsRedBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames do not conform to either the CIR/CBS or the EIR/EBS
in this EVC for this Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 13 }
tnEthSoamPmEvcHistoryStatsDiscardFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames which
were chosen to be discarded in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 14 }
tnEthSoamPmEvcHistoryStatsDiscardFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames which
were chosen to be discarded in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 15 }
tnEthSoamPmEvcHistoryStatsDiscardBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes which
were chosen to be discarded in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 16 }
tnEthSoamPmEvcHistoryStatsDiscardBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes which
were chosen to be discarded in this EVC for this
Measurement Interval.
"
::= { tnEthSoamPmEvcHistoryStatsEntry 17 }
-- ******************************************************************
-- TN Ethernet ECE History Statistic Table
-- ******************************************************************
tnEthSoamPmEceHistoryStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnEthSoamPmEceHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the results for history Measurement
Intervals in a SOAM EVC Extention (ECE) Measurement session.
It provides port statistics for the UNI ports of EVC.
Rows of this table object are created automatically
by the SNMP Agent when the ECE Measurement session is running and a
Measurement Interval is completed.
Each row in the table represents the history statistics for a ECE
Measurement session availability Measurement Interval for the defined
ECE.
32 completed Measurement Intervals are to be supported. If
there are at least 32 rows in the table and a new Measurement Interval
completes and a new row is to be added to the table, the oldest completed
Measurement Interval is deleted (row deletion).
The rows and objects in this table are to be persistent upon reboot
or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
for tnEthSoamPmSessionCfgType of 'ece'
"
::= { tnEthSoamPmEceStatsObjects 1 }
tnEthSoamPmEceHistoryStatsEntry OBJECT-TYPE
SYNTAX TnEthSoamPmEceHistoryStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The conceptual row of tnEthSoamPmEceHistoryStatsTable"
INDEX { tnEthSoamPmEceHistoryStatsIndex, tnEvcEceId, ifIndex }
::= { tnEthSoamPmEceHistoryStatsTable 1 }
TnEthSoamPmEceHistoryStatsEntry ::= SEQUENCE {
tnEthSoamPmEceHistoryStatsIndex Unsigned32,
tnEthSoamPmEceHistoryStatsEndTime DateAndTime,
tnEthSoamPmEceHistoryStatsElapsedTime TimeInterval,
tnEthSoamPmEceHistoryStatsGreenFramesTx Counter64,
tnEthSoamPmEceHistoryStatsGreenFramesRx Counter64,
tnEthSoamPmEceHistoryStatsGreenBytesTx Counter64,
tnEthSoamPmEceHistoryStatsGreenBytesRx Counter64,
tnEthSoamPmEceHistoryStatsYellowFramesTx Counter64,
tnEthSoamPmEceHistoryStatsYellowFramesRx Counter64,
tnEthSoamPmEceHistoryStatsYellowBytesTx Counter64,
tnEthSoamPmEceHistoryStatsYellowBytesRx Counter64,
tnEthSoamPmEceHistoryStatsRedFramesRx Counter64,
tnEthSoamPmEceHistoryStatsRedBytesRx Counter64,
tnEthSoamPmEceHistoryStatsDiscardFramesTx Counter64,
tnEthSoamPmEceHistoryStatsDiscardFramesRx Counter64,
tnEthSoamPmEceHistoryStatsDiscardBytesTx Counter64,
tnEthSoamPmEceHistoryStatsDiscardBytesRx Counter64
}
tnEthSoamPmEceHistoryStatsIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index for the Measurement Interval within this PM session.
Measurement Interval indexes are assigned sequentially by
the device. The first Measurement Interval that occurs after
the session is started is assigned index 1.
Referential integrity is necessary, i.e., the index needs to be
persistent upon a reboot or restart of a device. The index
is never reused while this session is active until it wraps to zero.
The index value keeps increasing up to that time.
"
::= { tnEthSoamPmEceHistoryStatsEntry 1 }
tnEthSoamPmEceHistoryStatsEndTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval ended.
"
::= { tnEthSoamPmEceHistoryStatsEntry 2 }
tnEthSoamPmEceHistoryStatsElapsedTime OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time that this Measurement Interval has been running, in 0.01
seconds.
"
::= { tnEthSoamPmEceHistoryStatsEntry 3 }
tnEthSoamPmEceHistoryStatsGreenFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames within
the CIR / CBS compliance level in this ECE for this
Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 4 }
tnEthSoamPmEceHistoryStatsGreenFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames
within the CIR / CBS compliance level in this
ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 5 }
tnEthSoamPmEceHistoryStatsGreenBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes, where
frames are within the CIR / CBS compliance level in this
ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 6 }
tnEthSoamPmEceHistoryStatsGreenBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames are within the CIR / CBS compliance level in this
ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 7 }
tnEthSoamPmEceHistoryStatsYellowFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames
exceeding the CIR/CBS but within the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 8 }
tnEthSoamPmEceHistoryStatsYellowFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames
exceeding the CIR/CBS but within the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 9 }
tnEthSoamPmEceHistoryStatsYellowBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes, where
frames exceed the CIR/CBS but are within the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 10 }
tnEthSoamPmEceHistoryStatsYellowBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames exceed the CIR/CBS but are within the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 11 }
tnEthSoamPmEceHistoryStatsRedFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames
not conforming to either the CIR/CBS or the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 12 }
tnEthSoamPmEceHistoryStatsRedBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes, where
frames do not conform to either the CIR/CBS or the EIR/EBS
in this ECE for this Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 13 }
tnEthSoamPmEceHistoryStatsDiscardFramesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound frames which
were chosen to be discarded in this ECE for this
Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 14 }
tnEthSoamPmEceHistoryStatsDiscardFramesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound frames which
were chosen to be discarded in this ECE for this
Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 15 }
tnEthSoamPmEceHistoryStatsDiscardBytesTx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of outbound bytes which
were chosen to be discarded in this ECE for this
Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 16 }
tnEthSoamPmEceHistoryStatsDiscardBytesRx OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the number of inbound bytes which
were chosen to be discarded in this ECE for this
Measurement Interval.
"
::= { tnEthSoamPmEceHistoryStatsEntry 17 }
-- ******************************************************************
-- TN Ethernet Port History Statistic Table
-- ******************************************************************
-- tnEthSoamPmPortHistoryStatsTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF TnEthSoamPmPortHistoryStatsEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table contains the results for history Measurement
-- Intervals in a SOAM Port Measurement session.
--
-- Rows of this table object are created automatically by the
-- SNMP Agent when the Port Measurement session is running and a
-- Measurement Interval is completed.
--
-- Each row in the table represents the history statistics for a Port
-- Measurement session availability Measurement Interval for the defined
-- port.
--
-- 32 completed Measurement Intervals are to be supported. If
-- there are at least 32 rows in the table and a new Measurement Interval
-- completes and a new row is to be added to the table, the oldest completed
-- Measurement Interval is deleted (row deletion).
--
-- The rows and objects in this table are to be persistent upon reboot
-- or restart of a device if tnEthSoamPmSessionCfgStorageMode is enabled
-- for tnEthSoamPmSessionCfgType of 'port'.
-- "
-- ::= { tnEthSoamPmPortStatsObjects 1 }
--
-- tnEthSoamPmPortHistoryStatsEntry OBJECT-TYPE
-- SYNTAX TnEthSoamPmPortHistoryStatsEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The conceptual row of tnEthSoamPmPortHistoryStatsTable"
-- INDEX { tnEthSoamPmPortHistoryStatsIndex, ifIndex }
-- ::= { tnEthSoamPmPortHistoryStatsTable 1 }
--
-- TnEthSoamPmPortHistoryStatsEntry ::= SEQUENCE {
-- tnEthSoamPmPortHistoryStatsIndex Unsigned32,
-- tnEthSoamPmPortHistoryStatsEndTime DateAndTime,
-- tnEthSoamPmPortHistoryStatsElapsedTime TimeInterval,
-- tnEthSoamPmPortHistoryStatsTxOctets Counter64,
-- tnEthSoamPmPortHistoryStatsRxOctets Counter64,
-- tnEthSoamPmPortHistoryStatsTxPkts Counter64,
-- tnEthSoamPmPortHistoryStatsRxPkts Counter64,
-- tnEthSoamPmPortHistoryStatsTxBroadcastPkts Counter64,
-- tnEthSoamPmPortHistoryStatsRxBroadcastPkts Counter64,
-- tnEthSoamPmPortHistoryStatsTxMulticastPkts Counter64,
-- tnEthSoamPmPortHistoryStatsRxMulticastPkts Counter64
-- }
--
-- tnEthSoamPmPortHistoryStatsIndex OBJECT-TYPE
-- SYNTAX Unsigned32 (1..4294967295)
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "The index for the Measurement Interval within this PM session.
--
-- Measurement Interval indexes are assigned sequentially by
-- the device. The first Measurement Interval that occurs after
-- the session is started is assigned index 1.
--
-- Referential integrity is necessary, i.e., the index needs to be
-- persistent upon a reboot or restart of a device. The index
-- is never reused while this session is active until it wraps to zero.
-- The index value keeps increasing up to that time.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 1 }
--
-- tnEthSoamPmPortHistoryStatsEndTime OBJECT-TYPE
-- SYNTAX DateAndTime
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The time that this Measurement Interval ended.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 2 }
--
-- tnEthSoamPmPortHistoryStatsElapsedTime OBJECT-TYPE
-- SYNTAX TimeInterval
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The time that this Measurement Interval has been running, in 0.01
-- seconds.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 3 }
--
-- tnEthSoamPmPortHistoryStatsTxOctets OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of octets transmitted out of the interface
-- for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 4 }
--
-- tnEthSoamPmPortHistoryStatsRxOctets OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of octets received on the interface
-- for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 5 }
--
-- tnEthSoamPmPortHistoryStatsTxPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of packets transmitted out of the interface
-- for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 6 }
--
-- tnEthSoamPmPortHistoryStatsRxPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of packets received on the interface
-- for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 7 }
--
-- tnEthSoamPmPortHistoryStatsTxBroadcastPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of packets that higher-level protocols
-- requested be transmitted, and which were addressed to a
-- broadcast address at this sub-layer for this Measurement
-- Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 8 }
--
-- tnEthSoamPmPortHistoryStatsRxBroadcastPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The number of packets, delivered by this sub-layer to a
-- higher (sub-)layer, which were addressed to a broadcast
-- address at this sub-layer for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 9 }
--
-- tnEthSoamPmPortHistoryStatsTxMulticastPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The total number of packets that higher-level protocols
-- requested be transmitted, and which were addressed to a
-- multicast address at this sub-layer for this Measurement
-- Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 10 }
--
-- tnEthSoamPmPortHistoryStatsRxMulticastPkts OBJECT-TYPE
-- SYNTAX Counter64
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "The number of packets, delivered by this sub-layer to a
-- higher (sub-)layer, which were addressed to a multicast
-- address at this sub-layer for this Measurement Interval.
-- "
-- ::= { tnEthSoamPmPortHistoryStatsEntry 11 }
END