122 lines
3.6 KiB
Plaintext
122 lines
3.6 KiB
Plaintext
-- *****************************************************************
|
|
-- TN-FRA-MIB.my : TN Fault Relay Alarm MIB
|
|
--
|
|
-- Copyright (c) 2012 by Transition Networks, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
TN-FRA-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP FROM SNMPv2-CONF
|
|
entPhysicalIndex FROM ENTITY-MIB
|
|
ifIndex FROM IF-MIB
|
|
tnProducts FROM TRANSITION-SMI;
|
|
|
|
tnFraMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201206251030Z"
|
|
ORGANIZATION "Transition Networks, Inc."
|
|
CONTACT-INFO
|
|
"Transition Networks
|
|
Technical Support
|
|
|
|
10900 Red Circle Drive
|
|
Minnetonka, MN 55343 USA
|
|
Tel: +1-800-526-9267
|
|
|
|
E-mail: techsupport@transition.com"
|
|
DESCRIPTION
|
|
"The mib module for managing all transition products with FRA(Fault relay alarm)"
|
|
REVISION "201206250000Z"
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { tnProducts 21 }
|
|
|
|
tnFraObjects OBJECT IDENTIFIER
|
|
::= { tnFraMIB 1 }
|
|
|
|
tnFraMgmt OBJECT IDENTIFIER ::= { tnFraObjects 1 }
|
|
|
|
tnFraRelayAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER {normal(1),negated(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Change the state of the relay when an alarm condition is active
|
|
Normal (1): Relay is activated on alarm
|
|
Negated(2): Relay is de-activated on alarm
|
|
"
|
|
::= { tnFraMgmt 1 }
|
|
|
|
tnFraPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnFraPowerSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is used for configuring fault relay status of the powersupply modules"
|
|
::= { tnFraMgmt 2 }
|
|
|
|
tnFraPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX TnFraPowerSupplyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry contains configuration element of tnFraPowerSupplyTable"
|
|
INDEX { entPhysicalIndex }
|
|
::= { tnFraPowerSupplyTable 1 }
|
|
|
|
TnFraPowerSupplyEntry ::= SEQUENCE {
|
|
tnFraPowerSupplyState INTEGER
|
|
}
|
|
|
|
tnFraPowerSupplyState OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trigger fault relay alarm while monitored power supply is not present
|
|
Enabled(1) : Enable fault relay alarm.
|
|
Disabled(2): Disable fault relay alarm.
|
|
"
|
|
::= { tnFraPowerSupplyEntry 1 }
|
|
|
|
tnFraLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnFraLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This table is used for configuring fault relay status of the each port
|
|
"
|
|
::= { tnFraMgmt 3 }
|
|
|
|
tnFraLinkEntry OBJECT-TYPE
|
|
SYNTAX TnFraLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The entry list the tnFraLinkState priority of each port
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { tnFraLinkTable 1 }
|
|
|
|
TnFraLinkEntry ::= SEQUENCE {
|
|
tnFraLinkState INTEGER
|
|
}
|
|
tnFraLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trigger fault relay alarm while monitored Port is down
|
|
Enabled(1) : Enable fault relay alarm of the link.
|
|
Disabled(2): Disable fault relay alarm of the link.
|
|
"
|
|
::= { tnFraLinkEntry 1}
|
|
END
|
|
|