mibs/MIBS/vmware/VMWARE-NSX-MIB
2023-12-05 12:25:34 +01:00

13580 lines
510 KiB
Plaintext

-- **********************************************************
-- Copyright 2019-2022 VMware, Inc. All rights reserved.
-- **********************************************************
VMWARE-NSX-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION, DateAndTime
FROM SNMPv2-TC
vmwNSXsys
FROM VMWARE-ROOT-MIB;
vmwNSXsysMIB MODULE-IDENTITY
LAST-UPDATED "202202140000Z"
ORGANIZATION "VMware, Inc"
CONTACT-INFO
"VMware, Inc
3401 Hillview Ave
Palo Alto, CA 94304
Tel: 1-877-486-9273 or 650-427-5000
Fax: 650-427-5001
Web: http://kb.vmware.com/kb/1013445
"
DESCRIPTION
"In much the same way that server virtualization programmatically
creates, snapshots, deletes, and restores software-based virtual
machines (VMs), NSX-T Data Center network virtualization
programmatically creates, deletes, and restores software-based
virtual networks.
With network virtualization, the functional equivalent of a network
hypervisor reproduces the complete set of Layer 2 through Layer 7
networking services (for example, switching, routing, access control,
firewalling, QoS) in software. As a result, these services can be
programmatically assembled in any arbitrary combination, to produce
unique, isolated virtual networks in a matter of seconds.
For more information about NSX-T Data Center, please visit:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/
"
REVISION "202202140000Z"
DESCRIPTION
"This revision adds 174 new notifications for NSX-T Data Center 3.2.0"
REVISION "202108060000Z"
DESCRIPTION
"This revision adds 18 new notifications for NSX-T Data Center 3.1.3"
REVISION "202104220000Z"
DESCRIPTION
"This revision adds 12 new notifications for NSX-T Data Center 3.1.2"
REVISION "202103250000Z"
DESCRIPTION
"This revision adds 2 new notifications for NSX-T Data Center 3.0.3"
REVISION "202101300000Z"
DESCRIPTION
"This revision adds 2 new notifications for NSX-T Data Center 3.1.1"
REVISION "202010300000Z"
DESCRIPTION
"This revision adds 56 new notifications for NSX-T Data Center 3.1.0"
REVISION "202009220000Z"
DESCRIPTION
"This revision adds 10 new notifications for NSX-T Data Center 3.0.2"
REVISION "202006290000Z"
DESCRIPTION
"This revision adds 12 new notifications for NSX-T Data Center 3.0.1"
REVISION "202003240000Z"
DESCRIPTION
"Initial revision of NSX-T Data Center SNMP event notifications."
::= { vmwNSXsys 1 }
-- **********************************************************
-- Top-level MIB groups
-- **********************************************************
vmwNsxTDataCenterNotifications OBJECT-IDENTITY
STATUS current
DESCRIPTION
"All event notifications from NSX-T Data Center fall under this oid."
::= { vmwNSXsysMIB 0 }
vmwNsxTDataCenterData OBJECT-IDENTITY
STATUS current
DESCRIPTION
"All variables that are sent in NSX-T Data Center event notifications
fall under this oid."
::= { vmwNSXsysMIB 1 }
-- **********************************************************
-- Type definitions
-- **********************************************************
VmwNsxTDataCenterFeatureIdType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The NSX-T Data Center feature ID associated with the event.
For example, this value identifies the feature is managerHealth,
edgeHealth, loadBalancer, etc."
SYNTAX INTEGER {
managerHealth(1),
edgeHealth(2),
certificates(3),
passwordManagement(4),
licenses(5),
intelligenceHealth(6),
infrastructureCommunication(7),
intelligenceCommunication(9),
cniHealth(10),
ncpHealth(11),
nodeAgentsHealth(12),
endpointProtection(13),
vpn(15),
alarmManagement(16),
loadBalancer(17),
transportNodeHealth(18),
infrastructureService(19),
dhcp(20),
highAvailability(21),
capacity(22),
auditLogHealth(24),
routing(28),
dns(30),
distributedFirewall(31),
federation(32),
distributedIdsIps(33),
communication(35),
identityFirewall(36),
ipam(38),
gatewayFirewall(39),
clustering(40),
nsxApplicationPlatformCommunication(41),
mtuCheck(42),
nsxApplicationPlatformHealth(43),
edge(45),
nat(46)
}
VmwNsxTDataCenterEventTypeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the NSX-T Data Center event. The complete set of events
are reported by the NSX API GET /api/v1/events."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSeverityType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The severity of the NSX-T Data Center event. Currently only the
critical(2), error(3), warning(4) and informational(6) levels
are used, but the other levels may be used in future releases."
SYNTAX INTEGER {
emergency(0),
alert(1),
critical(2),
error(3),
warning(4),
notice(5),
informational(6),
debug(7)
}
VmwNsxTDataCenterNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The node ID from where a NSX-T Data Center event was emitted. A
node ID can be for a cluster node as reported by the NSX API
GET /api/v1/cluster. Or a node ID can be for a transport node
as reported by the NSX API GET /api/v1/transport-nodes."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNodeTypeType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The type of node from where a NSX-T Data Center event was emitted."
SYNTAX INTEGER {
manager(0),
edge(1),
esx(2),
kvm(3),
publiccloudgateway(4),
intelligence(5),
autonomousedge(6),
globalmanager(7)
}
VmwNsxTDataCenterEntityIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The ID of a NSX-T Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balancer rule as reported by
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
as reported by the NSX API GET /api/v1/trust-management/certificates."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSystemResourceUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The CPU, memory, or disk usage percentage of an NSX-T appliance. The
value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDiskPartitionNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of a disk partition in an NSX-T appliance. For example, the
name for the /tmp partition is '/tmp'."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLicenseEditionTypeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The edition type of an NSX-T license. For example, the type for an NSX-T
evaluation license is 'NSX Data Center Evaluation'."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterApplianceAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NSX appliance's IP address. The value is an IPv4 address."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCurrentGatewayStateType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The current gateway state. The value could be active/standby/admin down."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCurrentServiceStateType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The current service state. The value could be start/stop/restart/crashed."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDatapathResourceUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The CPU, memory, or disk usage percentage of the datapath on a NSX-T appliance.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDHCPPoolUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The usage of a DHCP pool. The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeServiceNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the service running on the Edge node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFailureReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The detailed reason of any module failure like BGP down, IKE down, etc."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterPreviousGatewayStateType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The previous gateway state. The value could be active/standby/admin down."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterPreviousServiceStateType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The previous service state. The value could be start/stop/restart/crashed."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSystemUsageThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The configured threshold value for the CPU, memory, or disk usage
percentage of an NSX-T appliance. The value is an integer between 0 and
100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterUsernameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of a user in an NSX-T appliance."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDHCPServerIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The UUID of a DHCP server."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterServiceNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the service running in an NSX-T appliance."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterIntelligenceNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The node ID of an NSX-T Intelligence node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterHostnameOrIPAddressWithPortType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Hostname or ip address with port of logging server."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEventIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The event identifier."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterActiveGlobalManagerType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The identifier for the active Global Manager node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterActiveGlobalManagersType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"A comma delimited list of identifiers for the active Global Manager nodes."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSessionDownReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Down reason of the IPsec VPN session."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterManagerNodeNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The display name of a NSX-T Manager node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTransportNodeAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The IP address of a NSX-T Transport node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTransportNodeNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The display name of a NSX-T Transport node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCentralControlPlaneIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The UUID of a NSX centrol control plane."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTunnelDownReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Down reason of the IPsec VPN tunnel."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterHeapTypeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterMempoolNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Name of a memory pool."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterPasswordExpirationDaysType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The number of days left before expiration of the password of an NSX-T
appliance user. The value is an integer greater than 0."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterBGPNeighborIPType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLDAPServerType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name or IP address of a LDAP server."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterPeerAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"IP address of BFD peer."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterMaxIDSEventsAllowedType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The maximum number of IDS events that are allowed in the system, anything beyond this
would be purged at regular intervals."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterStaticAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"A Static IP address."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDuplicateIPAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Duplicate IP address."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCapacityDisplayNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Display name of type on capacity dashboard."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCapacityUsageCountType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current usage count of capacity usage type."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeNICNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NIC's receive descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
to accomodate new incoming packets and there is a significant drop due to it.
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NIC's transmit descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
to accomodate new outgoing packets and there is a significant drop due to it.
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSrIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Service Router UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterIDSEventsCountType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Count of the IDS events in the system currently."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRemoteSiteNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Name of a remote site in federation. For more information on remote
sites and an overview of the federation feature, please refer to:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterBGPSourceIPType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Source IP address of BGP session. This could be either an IPv4 address
in dotted-decimal format or an IPv6 address in IPv6 address format."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRemoteSiteIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The identifier for a remote site."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSiteIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The identifier for a local site."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSiteNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Name of a local site in federation. For more information on local
sites and an overview of the federation feature, please refer to:
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLrIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Logical Router UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRxMissesType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The number of packets missed while receiving due to rx ring buffer being full."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRxProcessedType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The number of successful incoming packets while polling for rx buffer full event."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTxMissesType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The number of packets missed while transmitting due to tx ring buffer being full."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTxProcessedType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The number of successful outgoing packets while polling for tx buffer full event."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLrportIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Logical Router Port UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterServiceIPType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The IP configured for the service running in an NSX-T appliance in dotted-decimal format."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRemoteManagerNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The remote Manager node UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDirectoryDomainType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of a directory domain."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTimeoutInMinutesType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Timeout value in minutes."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterMaxCapacityThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Maximum threshold defined for capacity usage type."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterMinCapacityThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Minimum threshold defined for capacity usage type."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterMaxSupportedCapacityCountType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Maximum supported count for capacity usage type."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLatencySourceType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The source of reported latency."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLatencyThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Threshold value of reported IO latency."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterLatencyValueType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Value of reported IO latency."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterApplianceFQDNType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NSX appliance's fully qualified domain name."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterRemoteApplianceAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The remote NSX appliance's IP address. The value is an IPv4 address."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterManagerNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The Manager node UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDisplayedLicenseKeyType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The last 5 characters of the license key of an NSX-T license."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeThreadNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the Edge node thread."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterIntentPathType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The policy intent path."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFirewallHalfopenFlowUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current firewall TCP half-open connection usage percentage of max supported value.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFirewallICMPFlowUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current firewall ICMP connection usage percentage of max supported value.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterServiceDownReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Reason service is down."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFirewallUDPFlowUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current firewall UDP connection usage percentage of max supported value.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFirewallIPFlowUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current firewall IP connection usage percentage of max supported value.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDNSIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The DNS forwarder identifier."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterDNSUpstreamIPType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"IP address of one DNS forwarder upstream server."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterCABundleAgeThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The age threshold in days for the CA bundle."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterAPICollectionPathType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The API path of the collection containing entity_id."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"String containing Policy/MP intent of Edge transport node settings
that differs from corresponding Edge transport node settings on Edge NSX CLI."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"String containing Policy/MP intent of Edge transport node vSphere
deployment configuration that differs from corresponding Edge transport node
configuration on vSphere."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFirewallSNATPortsUsageType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Current firewall SNAT ports usage percentage of max supported value.
The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"String containing Policy/MP intent of vSphere deployment configuration that differs
from corresponding Edge transport node configuration on vSphere when vMotion happens
for Edge node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"String containing Policy/MP intent of Edge transport node settings and vSphere
deployment configuration that differs from corresponding Edge transport node
settings on Edge NSX CLI and Edge transport node configuration on vSphere."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSNATIPAddressType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The SNAT IP address which ran out of port threshold."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNappClusterIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The cluster ID of the NSX Application Platform cluster."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNappMessagingLAGThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The configured threshold value for the number of pending messages
in an NSX Application Platform messaging topic."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNappNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The node ID of an NSX Application Platform node."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNappServiceNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The service name of an NSX Application Platform service."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFlowIdentifierType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"A flow identifier indicating the direction of flow of data which is one of following.
- GM_2_LM
- LM_2_GM_NOTIFICATION
- LM_2_GM_ONBOARD_CONFIG"
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterSyncIssueReasonType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"A reason for data synchronization issue."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterQueueNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The name of the queue used to synchronize data between two sites."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterQueueSizeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The occupancy size of queue used to synchronize data between two sites."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterQueueSizeThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Maximum threshold value of reported queue size."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterGroupTypeType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The group type of a GMLE cluster."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterManagerNodeIDSType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"A comma delimited list of identifiers for the Manager nodes."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterServiceRouterIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The ID of a service-router that is part of a tier0 or tier1 gateway
spanning one or more edges"
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterTransportNodeIdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The Transport node UUID."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterFromGMPathType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Policy path of the Global Manager."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterToGMPathType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Policy path of the Global Manager."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNICThroughputType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NIC throughput, as a percentage. The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNICThroughputThresholdType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The NIC throughput threshold, as a percentage. The value is an integer between 0 and 100."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterEdgeCryptoDrvNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"Name of the edge crypto driver."
SYNTAX OCTET STRING (SIZE (0..256))
VmwNsxTDataCenterNappNodeNameType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "256a"
STATUS current
DESCRIPTION
"The node name of an NSX Application Platform node."
SYNTAX OCTET STRING (SIZE (0..256))
vmwNsxTDataCenterTimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The timestamp when the NSX-T Data Center event occurred."
::= { vmwNsxTDataCenterData 1 }
vmwNsxTDataCenterFeatureName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFeatureIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The NSX-T Data Center feature ID associated with the event."
::= { vmwNsxTDataCenterData 2 }
vmwNsxTDataCenterEventType OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEventTypeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the NSX-T Data Center event."
::= { vmwNsxTDataCenterData 3 }
vmwNsxTDataCenterEventSeverity OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSeverityType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The severity of the NSX-T Data Center event."
::= { vmwNsxTDataCenterData 4 }
vmwNsxTDataCenterNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The node ID from where a NSX-T Data Center event was emitted."
::= { vmwNsxTDataCenterData 5 }
vmwNsxTDataCenterNodeType OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNodeTypeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The type of node from where a NSX-T Data Center event was emitted."
::= { vmwNsxTDataCenterData 6 }
vmwNsxTDataCenterEntityId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEntityIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The ID of a NSX-T Data Center entity an event pertains to. The event
description field provides additional details of the entity. For
example the ID can be for a specific Load Balancer rule as reported by
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
as reported by the NSX API GET /api/v1/trust-management/certificates."
::= { vmwNsxTDataCenterData 21 }
vmwNsxTDataCenterSystemResourceUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSystemResourceUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The CPU, memory, or disk usage percentage of an NSX-T appliance. The
value is an integer between 0 and 100."
::= { vmwNsxTDataCenterData 22 }
vmwNsxTDataCenterDiskPartitionName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDiskPartitionNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of a disk partition in an NSX-T appliance. For example, the
name for the /tmp partition is '/tmp'."
::= { vmwNsxTDataCenterData 23 }
vmwNsxTDataCenterLicenseEditionType OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLicenseEditionTypeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The edition type of an NSX-T license. For example, the type for an NSX-T
evaluation license is 'NSX Data Center Evaluation'."
::= { vmwNsxTDataCenterData 24 }
vmwNsxTDataCenterApplianceAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterApplianceAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The NSX appliance's IP address. The value is an IPv4 address."
::= { vmwNsxTDataCenterData 25 }
vmwNsxTDataCenterCurrentGatewayState OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCurrentGatewayStateType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current gateway state. The value could be active/standby/admin down."
::= { vmwNsxTDataCenterData 26 }
vmwNsxTDataCenterCurrentServiceState OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCurrentServiceStateType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current service state. The value could be start/stop/restart/crashed."
::= { vmwNsxTDataCenterData 27 }
vmwNsxTDataCenterDatapathResourceUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDatapathResourceUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The CPU, memory, or disk usage percentage of the datapath on a NSX-T appliance.
The value is an integer between 0 and 100."
::= { vmwNsxTDataCenterData 28 }
vmwNsxTDataCenterDHCPPoolUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDHCPPoolUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The usage of a DHCP pool. The value is an integer between 0 and 100."
::= { vmwNsxTDataCenterData 29 }
vmwNsxTDataCenterEdgeServiceName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeServiceNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the service running on the Edge node."
::= { vmwNsxTDataCenterData 30 }
vmwNsxTDataCenterFailureReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFailureReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The detailed reason of any module failure like BGP down, IKE down, etc."
::= { vmwNsxTDataCenterData 31 }
vmwNsxTDataCenterPreviousGatewayState OBJECT-TYPE
SYNTAX VmwNsxTDataCenterPreviousGatewayStateType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The previous gateway state. The value could be active/standby/admin down."
::= { vmwNsxTDataCenterData 32 }
vmwNsxTDataCenterPreviousServiceState OBJECT-TYPE
SYNTAX VmwNsxTDataCenterPreviousServiceStateType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The previous service state. The value could be start/stop/restart/crashed."
::= { vmwNsxTDataCenterData 33 }
vmwNsxTDataCenterSystemUsageThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSystemUsageThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The configured threshold value for the CPU, memory, or disk usage
percentage of an NSX-T appliance. The value is an integer between 0 and
100."
::= { vmwNsxTDataCenterData 34 }
vmwNsxTDataCenterUsername OBJECT-TYPE
SYNTAX VmwNsxTDataCenterUsernameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of a user in an NSX-T appliance."
::= { vmwNsxTDataCenterData 35 }
vmwNsxTDataCenterDHCPServerId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDHCPServerIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The UUID of a DHCP server."
::= { vmwNsxTDataCenterData 36 }
vmwNsxTDataCenterServiceName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterServiceNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the service running in an NSX-T appliance."
::= { vmwNsxTDataCenterData 37 }
vmwNsxTDataCenterIntelligenceNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterIntelligenceNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The node ID of an NSX-T Intelligence node."
::= { vmwNsxTDataCenterData 38 }
vmwNsxTDataCenterHostnameOrIPAddressWithPort OBJECT-TYPE
SYNTAX VmwNsxTDataCenterHostnameOrIPAddressWithPortType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 39 }
vmwNsxTDataCenterEventId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEventIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The event identifier."
::= { vmwNsxTDataCenterData 40 }
vmwNsxTDataCenterActiveGlobalManager OBJECT-TYPE
SYNTAX VmwNsxTDataCenterActiveGlobalManagerType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 41 }
vmwNsxTDataCenterActiveGlobalManagers OBJECT-TYPE
SYNTAX VmwNsxTDataCenterActiveGlobalManagersType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 42 }
vmwNsxTDataCenterSessionDownReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSessionDownReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Down reason of the IPsec VPN session."
::= { vmwNsxTDataCenterData 43 }
vmwNsxTDataCenterManagerNodeName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterManagerNodeNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 44 }
vmwNsxTDataCenterTransportNodeAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTransportNodeAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 45 }
vmwNsxTDataCenterTransportNodeName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTransportNodeNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 46 }
vmwNsxTDataCenterCentralControlPlaneId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCentralControlPlaneIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 47 }
vmwNsxTDataCenterTunnelDownReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTunnelDownReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Down reason of the IPsec VPN tunnel."
::= { vmwNsxTDataCenterData 48 }
vmwNsxTDataCenterHeapType OBJECT-TYPE
SYNTAX VmwNsxTDataCenterHeapTypeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
::= { vmwNsxTDataCenterData 49 }
vmwNsxTDataCenterMempoolName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterMempoolNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Name of a memory pool."
::= { vmwNsxTDataCenterData 50 }
vmwNsxTDataCenterPasswordExpirationDays OBJECT-TYPE
SYNTAX VmwNsxTDataCenterPasswordExpirationDaysType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The number of days left before expiration of the password of an NSX-T
appliance user. The value is an integer greater than 0."
::= { vmwNsxTDataCenterData 51 }
vmwNsxTDataCenterBGPNeighborIP OBJECT-TYPE
SYNTAX VmwNsxTDataCenterBGPNeighborIPType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
::= { vmwNsxTDataCenterData 52 }
vmwNsxTDataCenterLDAPServer OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLDAPServerType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 53 }
vmwNsxTDataCenterPeerAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterPeerAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"IP address of BFD peer."
::= { vmwNsxTDataCenterData 54 }
vmwNsxTDataCenterMaxIDSEventsAllowed OBJECT-TYPE
SYNTAX VmwNsxTDataCenterMaxIDSEventsAllowedType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 55 }
vmwNsxTDataCenterStaticAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterStaticAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A Static IP address."
::= { vmwNsxTDataCenterData 56 }
vmwNsxTDataCenterDuplicateIPAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDuplicateIPAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Duplicate IP address."
::= { vmwNsxTDataCenterData 57 }
vmwNsxTDataCenterCapacityDisplayName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCapacityDisplayNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 58 }
vmwNsxTDataCenterCapacityUsageCount OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCapacityUsageCountType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 59 }
vmwNsxTDataCenterEdgeNICName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeNICNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
::= { vmwNsxTDataCenterData 60 }
vmwNsxTDataCenterRxRingBufferOverflowPercentage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRxRingBufferOverflowPercentageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The NIC's receive descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
to accomodate new incoming packets and there is a significant drop due to it.
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
::= { vmwNsxTDataCenterData 61 }
vmwNsxTDataCenterTxRingBufferOverflowPercentage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTxRingBufferOverflowPercentageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The NIC's transmit descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
to accomodate new outgoing packets and there is a significant drop due to it.
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
::= { vmwNsxTDataCenterData 62 }
vmwNsxTDataCenterSrId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSrIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Service Router UUID."
::= { vmwNsxTDataCenterData 63 }
vmwNsxTDataCenterIDSEventsCount OBJECT-TYPE
SYNTAX VmwNsxTDataCenterIDSEventsCountType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 64 }
vmwNsxTDataCenterRemoteSiteName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRemoteSiteNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 65 }
vmwNsxTDataCenterBGPSourceIP OBJECT-TYPE
SYNTAX VmwNsxTDataCenterBGPSourceIPType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 66 }
vmwNsxTDataCenterRemoteSiteId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRemoteSiteIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 67 }
vmwNsxTDataCenterSiteId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSiteIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 68 }
vmwNsxTDataCenterSiteName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSiteNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 69 }
vmwNsxTDataCenterLrId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLrIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 70 }
vmwNsxTDataCenterRxMisses OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRxMissesType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 71 }
vmwNsxTDataCenterRxProcessed OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRxProcessedType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 72 }
vmwNsxTDataCenterTxMisses OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTxMissesType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 73 }
vmwNsxTDataCenterTxProcessed OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTxProcessedType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 74 }
vmwNsxTDataCenterLrportId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLrportIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Logical Router Port UUID."
::= { vmwNsxTDataCenterData 75 }
vmwNsxTDataCenterServiceIP OBJECT-TYPE
SYNTAX VmwNsxTDataCenterServiceIPType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The Ip configured for the service running in an NSX-T appliance."
::= { vmwNsxTDataCenterData 77 }
vmwNsxTDataCenterRemoteManagerNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRemoteManagerNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 80 }
vmwNsxTDataCenterDirectoryDomain OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDirectoryDomainType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 81 }
vmwNsxTDataCenterTimeoutInMinutes OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTimeoutInMinutesType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 82 }
vmwNsxTDataCenterMaxCapacityThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterMaxCapacityThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 83 }
vmwNsxTDataCenterMinCapacityThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterMinCapacityThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 84 }
vmwNsxTDataCenterMaxSupportedCapacityCount OBJECT-TYPE
SYNTAX VmwNsxTDataCenterMaxSupportedCapacityCountType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 85 }
vmwNsxTDataCenterLatencySource OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLatencySourceType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 86 }
vmwNsxTDataCenterLatencyThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLatencyThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 87 }
vmwNsxTDataCenterLatencyValue OBJECT-TYPE
SYNTAX VmwNsxTDataCenterLatencyValueType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 88 }
vmwNsxTDataCenterApplianceFQDN OBJECT-TYPE
SYNTAX VmwNsxTDataCenterApplianceFQDNType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 89 }
vmwNsxTDataCenterRemoteApplianceAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterRemoteApplianceAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 90 }
vmwNsxTDataCenterManagerNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterManagerNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 91 }
vmwNsxTDataCenterDisplayedLicenseKey OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDisplayedLicenseKeyType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 92 }
vmwNsxTDataCenterEdgeThreadName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeThreadNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 93 }
vmwNsxTDataCenterIntentPath OBJECT-TYPE
SYNTAX VmwNsxTDataCenterIntentPathType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 94 }
vmwNsxTDataCenterFirewallHalfopenFlowUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFirewallHalfopenFlowUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Firewall TCP half-open connection usage."
::= { vmwNsxTDataCenterData 95 }
vmwNsxTDataCenterFirewallICMPFlowUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFirewallICMPFlowUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Firewall ICMP connection usage."
::= { vmwNsxTDataCenterData 96 }
vmwNsxTDataCenterServiceDownReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterServiceDownReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 97 }
vmwNsxTDataCenterFirewallUDPFlowUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFirewallUDPFlowUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Firewall UDP connection usage."
::= { vmwNsxTDataCenterData 98 }
vmwNsxTDataCenterFirewallIPFlowUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFirewallIPFlowUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Firewall IP connection usage."
::= { vmwNsxTDataCenterData 99 }
vmwNsxTDataCenterDNSId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDNSIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"DNS forwarder identifier."
::= { vmwNsxTDataCenterData 100 }
vmwNsxTDataCenterDNSUpstreamIP OBJECT-TYPE
SYNTAX VmwNsxTDataCenterDNSUpstreamIPType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"DNS forwarder upstream server IP address."
::= { vmwNsxTDataCenterData 101 }
vmwNsxTDataCenterCABundleAgeThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterCABundleAgeThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 121 }
vmwNsxTDataCenterAPICollectionPath OBJECT-TYPE
SYNTAX VmwNsxTDataCenterAPICollectionPathType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 122 }
vmwNsxTDataCenterEdgeNodeSettingMismatchReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 123 }
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 124 }
vmwNsxTDataCenterFirewallSNATPortsUsage OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFirewallSNATPortsUsageType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 125 }
vmwNsxTDataCenterEdgevSphereLocationMismatchReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 126 }
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 127 }
vmwNsxTDataCenterSNATIPAddress OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSNATIPAddressType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 128 }
vmwNsxTDataCenterNappClusterId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNappClusterIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 129 }
vmwNsxTDataCenterNappMessagingLAGThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNappMessagingLAGThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 130 }
vmwNsxTDataCenterNappNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNappNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 131 }
vmwNsxTDataCenterNappServiceName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNappServiceNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 132 }
vmwNsxTDataCenterFlowIdentifier OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFlowIdentifierType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 133 }
vmwNsxTDataCenterSyncIssueReason OBJECT-TYPE
SYNTAX VmwNsxTDataCenterSyncIssueReasonType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 134 }
vmwNsxTDataCenterQueueName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterQueueNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 135 }
vmwNsxTDataCenterQueueSize OBJECT-TYPE
SYNTAX VmwNsxTDataCenterQueueSizeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 136 }
vmwNsxTDataCenterQueueSizeThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterQueueSizeThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 137 }
vmwNsxTDataCenterGroupType OBJECT-TYPE
SYNTAX VmwNsxTDataCenterGroupTypeType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 138 }
vmwNsxTDataCenterManagerNodeIDS OBJECT-TYPE
SYNTAX VmwNsxTDataCenterManagerNodeIDSType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 139 }
vmwNsxTDataCenterServiceRouterId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterServiceRouterIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 140 }
vmwNsxTDataCenterTransportNodeId OBJECT-TYPE
SYNTAX VmwNsxTDataCenterTransportNodeIdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 141 }
vmwNsxTDataCenterFromGMPath OBJECT-TYPE
SYNTAX VmwNsxTDataCenterFromGMPathType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 142 }
vmwNsxTDataCenterToGMPath OBJECT-TYPE
SYNTAX VmwNsxTDataCenterToGMPathType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 143 }
vmwNsxTDataCenterNICThroughput OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNICThroughputType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 144 }
vmwNsxTDataCenterNICThroughputThreshold OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNICThroughputThresholdType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 145 }
vmwNsxTDataCenterEdgeCryptoDrvName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterEdgeCryptoDrvNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 146 }
vmwNsxTDataCenterNappNodeName OBJECT-TYPE
SYNTAX VmwNsxTDataCenterNappNodeNameType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This value is not expected to be empty."
::= { vmwNsxTDataCenterData 147 }
-- **********************************************************
-- AlarmManagement feature event notifications
-- **********************************************************
vmwNsxTAlarmManagementFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the AlarmManagement feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 16 }
vmwNsxTAlarmManagementFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for AlarmManagement feature notifications.
"
::= { vmwNsxTAlarmManagementFeaturePrefix 0 }
vmwNsxTAlarmManagementAlarmServiceOverloaded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Due to heavy volume of alarms reported, the alarm service is temporarily
overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped
reporting new alarms; however, syslog entries and SNMP traps (if enabled)
are still being emitted reporting the underlying event details. When the
underlying issues causing the heavy volume of alarms are addressed, the
alarm service will start reporting new alarms again.
Action required:
Review all active alarms using the Alarms page in the NSX UI or using the
GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each
active alarm investigate the root cause by following the recommended action
for the alarm. When sufficient alarms are resolved, the alarm service will
start reporting new alarms again.
"
::= { vmwNsxTAlarmManagementFeature 1 }
vmwNsxTAlarmManagementAlarmServiceOverloadedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The heavy volume of alarms has subsided and new alarms are being reported
again.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTAlarmManagementFeature 2 }
vmwNsxTAlarmManagementHeavyVolumeOfAlarms NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEventId
}
STATUS current
DESCRIPTION
"Due to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has
temporarily stopped reporting alarms of this type. The NSX UI and
GET /api/v1/alarms NSX API are not reporting new instances of these
alarms; however, syslog entries and SNMP traps (if enabled) are
still being emitted reporting the underlying event details. When the
underlying issues causing the heavy volume of vmwNsxTDataCenterEventId alarms are
addressed, the alarm service will start reporting new vmwNsxTDataCenterEventId
alarms when new issues are detected again.
Action required:
Review all active alarms of type vmwNsxTDataCenterEventId using the
Alarms page in the NSX UI or using the NSX API GET
/api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED. For each active
alarm investigate the root cause by following the recommended action
for the alarm. When sufficient alarms are resolved, the alarm service
will start reporting new vmwNsxTDataCenterEventId alarms again.
"
::= { vmwNsxTAlarmManagementFeature 3 }
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEventId
}
STATUS current
DESCRIPTION
"The heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of
this type are being reported again.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTAlarmManagementFeature 4 }
-- **********************************************************
-- AuditLogHealth feature event notifications
-- **********************************************************
vmwNsxTAuditLogHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the AuditLogHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 24 }
vmwNsxTAuditLogHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for AuditLogHealth feature notifications.
"
::= { vmwNsxTAuditLogHealthFeaturePrefix 0 }
vmwNsxTAuditLogHealthAuditLogFileUpdateError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"At least one of the monitored log files has read-only permissions or has
incorrect user/group ownership or rsyslog.log is missing on Manager,
Global Manager, Edge or Public Cloud Gateway nodes.
Action required:
1. On all NSX appliances, for example Manager nodes, Edge nodes, etc.,
ensure the permissions for the /var/log directory is 775 and the ownership
is root:syslog.
2. On Manager and Global Manager nodes, ensure the file permissions
for auth.log, nsx-audit.log, nsx-audit-write.log, rsyslog.log and syslog
under /var/log is 640 and ownership is syslog:admin.
3. On Edge and Public Cloud Gateway nodes, ensure the file permissions
for rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin.
4. On ESXi host nodes, ensure the file permissions of auth.log, nsx-syslog.log
and syslog.log under /var/log is 755 and ownership is root:root.
5. On KVM host nodes, ensure the file permissions of auth.log and syslog
under /var/log is 775 and ownership is root:syslog.
6. If any of these files have incorrect permissions or ownership, invoke the
commands `chmod <mode> <path>` and `chown <user>:<group> <path>`.
7. If rsyslog.log is missing on Manager, Global Manager, Edge or Public
Cloud Gateway nodes, invoke the NSX CLI command `restart service syslog`
which restarts the logging service and regenerates /var/log/rsyslog.log.
"
::= { vmwNsxTAuditLogHealthFeature 1 }
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"All monitored log files have the correct file permissions and ownership
and rsyslog.log exists on Manager, Global Manager, Edge or Public
Cloud Gateway nodes.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTAuditLogHealthFeature 2 }
vmwNsxTAuditLogHealthRemoteLoggingServerError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterHostnameOrIPAddressWithPort
}
STATUS current
DESCRIPTION
"Log messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
cannot be delivered possibly due to an unresolvable FQDN, an invalid TLS
certificate or missing NSX appliance iptables rule.
Action required:
1. Ensure that vmwNsxTDataCenterHostnameOrIPAddressWithPort is the correct hostname or
IP address and port.
2. If the logging server is specified using a FQDN, ensure the FQDN is resolvable
from the NSX appliance using the NSX CLI command `nslookup <fqdn>`. If not
resolvable, verify the correct FQDN is specified and the network DNS server has
the required entry for the FQDN.
3. If the logging server is configured to use TLS, verify the specified certificate
is valid. For example, ensure the logging server is actually using the certificate
or verify the certificate has not expired using the openssl command
`openssl x509 -in <cert-file-path> -noout -dates`.
4. NSX appliances use iptables rules to explicitly allow outgoing traffic. Verify
the iptables rule for the logging server is configured properly by invoking the
NSX CLI command `verify logging-servers` which re-configures logging server
iptables rules as needed.
5. If for any reason the logging server is misconfigured, it should be deleted
using the NSX CLI `del logging-server <hostname-or-ip-address[:port]>
proto <proto> level <level>` command and re-added with the correct configuration.
"
::= { vmwNsxTAuditLogHealthFeature 3 }
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterHostnameOrIPAddressWithPort
}
STATUS current
DESCRIPTION
"Configuration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
appear correct.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTAuditLogHealthFeature 4 }
-- **********************************************************
-- Capacity feature event notifications
-- **********************************************************
vmwNsxTCapacityFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Capacity feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 22 }
vmwNsxTCapacityFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Capacity feature notifications.
"
::= { vmwNsxTCapacityFeaturePrefix 0 }
vmwNsxTCapacityMaximumCapacity NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMaxSupportedCapacityCount
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum supported
count of vmwNsxTDataCenterMaxSupportedCapacityCount.
Action required:
Ensure that the number of NSX objects created is within the limits
supported by NSX. If there are any unused objects, delete them using the
respective NSX UI or API from the system.
Consider increasing the form factor of all Manager nodes and/or Edge
nodes. Note that the form factor of each node type should be the
same. If not the same, the capacity limits for the lowest form factor
deployed are used.
"
::= { vmwNsxTCapacityFeature 1 }
vmwNsxTCapacityMaximumCapacityClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMaxSupportedCapacityCount
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum supported count of
vmwNsxTDataCenterMaxSupportedCapacityCount.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCapacityFeature 2 }
vmwNsxTCapacityMaximumCapacityThreshold NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMaxCapacityThreshold
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum capacity
threshold of vmwNsxTDataCenterMaxCapacityThreshold%.
Action required:
Navigate to the capacity page in the NSX UI and review current usage versus
threshold limits. If the current usage is expected, consider increasing the
maximum threshold values. If the current usage is unexpected, review the
network policies configured to decrease usage at or below the maximum threshold.
"
::= { vmwNsxTCapacityFeature 3 }
vmwNsxTCapacityMaximumCapacityThresholdClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMaxCapacityThreshold
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum capacity threshold
of vmwNsxTDataCenterMaxCapacityThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCapacityFeature 4 }
vmwNsxTCapacityMinimumCapacityThreshold NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMinCapacityThreshold
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum capacity
threshold of vmwNsxTDataCenterMinCapacityThreshold%.
Action required:
Navigate to the capacity page in the NSX UI and review current usage versus
threshold limits. If the current usage is expected, consider increasing the
minimum threshold values. If the current usage is unexpected, review the
network policies configured to decrease usage at or below the minimum threshold.
"
::= { vmwNsxTCapacityFeature 5 }
vmwNsxTCapacityMinimumCapacityThresholdClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterMinCapacityThreshold
}
STATUS current
DESCRIPTION
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the minimum capacity threshold
of vmwNsxTDataCenterMinCapacityThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCapacityFeature 6 }
-- **********************************************************
-- Certificates feature event notifications
-- **********************************************************
vmwNsxTCertificatesFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Certificates feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 3 }
vmwNsxTCertificatesFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Certificates feature notifications.
"
::= { vmwNsxTCertificatesFeaturePrefix 0 }
vmwNsxTCertificatesCABundleUpdateRecommended NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCABundleAgeThreshold
}
STATUS current
DESCRIPTION
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
vmwNsxTDataCenterCABundleAgeThreshold days ago.
Update for the trusted CA bundle is recommended.
Action required:
Ensure services that are currently using the trusted CA bundle are updated
to use a recently-updated trusted CA bundle. Unless it is system-provided
bundle, the bundle can be updated using the
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
Once the expired bundle is no longer in use, it should be deleted (if not
system-provided) by invoking the
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
"
::= { vmwNsxTCertificatesFeature 7 }
vmwNsxTCertificatesCABundleUpdateRecommendedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
in use.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCertificatesFeature 8 }
vmwNsxTCertificatesCABundleUpdateSuggested NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCABundleAgeThreshold
}
STATUS current
DESCRIPTION
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
vmwNsxTDataCenterCABundleAgeThreshold days ago.
Update for the trusted CA bundle is suggested.
Action required:
Ensure services that are currently using the trusted CA bundle are updated
to use a recently-updated trusted CA bundle. Unless it is system-provided
bundle, the bundle can be updated using the
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
Once the expired bundle is no longer in use, it should be deleted (if not
system-provided) by invoking the
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
"
::= { vmwNsxTCertificatesFeature 9 }
vmwNsxTCertificatesCABundleUpdateSuggestedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
in use.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCertificatesFeature 10 }
vmwNsxTCertificatesCertificateExpirationApproaching NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterAPICollectionPath
}
STATUS current
DESCRIPTION
"Certificate vmwNsxTDataCenterEntityId is approaching expiration.
Action required:
Ensure services that are currently using the certificate are updated
to use a new, non-expiring certificate. Once the expiring
certificate is no longer in use, it should be deleted by invoking the
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
"
::= { vmwNsxTCertificatesFeature 1 }
vmwNsxTCertificatesCertificateExpirationApproachingClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
approaching expiration.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCertificatesFeature 2 }
vmwNsxTCertificatesCertificateExpired NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterAPICollectionPath
}
STATUS current
DESCRIPTION
"Certificate vmwNsxTDataCenterEntityId has expired.
Action required:
Ensure services that are currently using the certificate are updated
to use a new, non-expired certificate. Once the expired
certificate is no longer in use, it should be deleted by invoking the
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
If the expired certificate is used by NAPP Platform,
the connection is broken between NSX and NAPP Platform.
Please check the NAPP Platform troubleshooting document
to use a self-signed NAPP CA certificate for recovering the connection.
"
::= { vmwNsxTCertificatesFeature 3 }
vmwNsxTCertificatesCertificateExpiredClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer
expired.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCertificatesFeature 4 }
vmwNsxTCertificatesCertificateIsAboutToExpire NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterAPICollectionPath
}
STATUS current
DESCRIPTION
"Certificate vmwNsxTDataCenterEntityId is about to expire.
Action required:
Ensure services that are currently using the certificate are updated
to use a new, non-expiring certificate. Once the expiring
certificate is no longer in use, it should be deleted by invoking the
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
"
::= { vmwNsxTCertificatesFeature 5 }
vmwNsxTCertificatesCertificateIsAboutToExpireClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
about to expire.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCertificatesFeature 6 }
-- **********************************************************
-- Clustering feature event notifications
-- **********************************************************
vmwNsxTClusteringFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Clustering feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 40 }
vmwNsxTClusteringFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Clustering feature notifications.
"
::= { vmwNsxTClusteringFeaturePrefix 0 }
vmwNsxTClusteringClusterDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterGroupType
}
STATUS current
DESCRIPTION
"Group member vmwNsxTDataCenterManagerNodeId of service vmwNsxTDataCenterGroupType is down.
Action required:
1. Invoke the NSX CLI command 'get cluster status' to view the status
of group members of the cluster.
2. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
/api/v1/node/services/<service_name>/status NSX API or the
`get service <service_name>` NSX CLI command to determine if the service is running.
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
the `restart service <service_name>` NSX CLI to restart the service.
3. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
"
::= { vmwNsxTClusteringFeature 1 }
vmwNsxTClusteringClusterDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterGroupType
}
STATUS current
DESCRIPTION
"Group member vmwNsxTDataCenterManagerNodeId of vmwNsxTDataCenterGroupType is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTClusteringFeature 2 }
vmwNsxTClusteringClusterUnavailable NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeIDS,
vmwNsxTDataCenterGroupType
}
STATUS current
DESCRIPTION
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are down.
Action required:
1. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
/api/v1/node/services/<service_name>/status NSX API or the
`get service <service_name>` NSX CLI command to determine if the service is running.
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
the `restart service <service_name>` NSX CLI to restart the service.
2. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
"
::= { vmwNsxTClusteringFeature 3 }
vmwNsxTClusteringClusterUnavailableClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeIDS,
vmwNsxTDataCenterGroupType
}
STATUS current
DESCRIPTION
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTClusteringFeature 4 }
-- **********************************************************
-- CniHealth feature event notifications
-- **********************************************************
vmwNsxTCniHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the CniHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 10 }
vmwNsxTCniHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for CniHealth feature notifications.
"
::= { vmwNsxTCniHealthFeaturePrefix 0 }
vmwNsxTCniHealthHyperbusManagerConnectionDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Hyperbus cannot communicate with the Manager node.
Action required:
The hyperbus vmkernel interface (vmk50) may be missing. Please refer to
Knowledge Base article https://kb.vmware.com/s/article/67432.
"
::= { vmwNsxTCniHealthFeature 3 }
vmwNsxTCniHealthHyperbusManagerConnectionDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Hyperbus can communicate with the Manager node.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCniHealthFeature 4 }
-- **********************************************************
-- Communication feature event notifications
-- **********************************************************
vmwNsxTCommunicationFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Communication feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 35 }
vmwNsxTCommunicationFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Communication feature notifications.
"
::= { vmwNsxTCommunicationFeaturePrefix 0 }
vmwNsxTCommunicationControlChannelToManagerNodeDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterTimeoutInMinutes
}
STATUS current
DESCRIPTION
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
Action required:
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
interface via ping. If they are not pingable, check for flakiness in network connectivity.
2. Check to see if the TCP connections are established using the netstat output to see if the
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
You can check whether the Transport node is in maintenance mode via the following API:
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
When maintenance mode is set, the Transport node will not be connected to the Controller
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
check connectivity again.
Note: Please note that this alarm is not critical and should be resolved. GSS need not be
contacted for the notification of this alarm unless the alarm remains unresolved over an
extended period of time.
"
::= { vmwNsxTCommunicationFeature 7 }
vmwNsxTCommunicationControlChannelToManagerNodeDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
vmwNsxTDataCenterApplianceAddress.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 8 }
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterTimeoutInMinutes
}
STATUS current
DESCRIPTION
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
Action required:
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
interface via ping. If they are not pingable, check for flakiness in network connectivity.
2. Check to see if the TCP connections are established using the netstat output to see if the
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
You can check whether the Transport node is in maintenance mode via the following API:
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>.
When maintenance mode is set, the Transport node will not be connected to the Controller
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
check connectivity again.
"
::= { vmwNsxTCommunicationFeature 9 }
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
vmwNsxTDataCenterApplianceAddress.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 10 }
vmwNsxTCommunicationControlChannelToTransportNodeDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCentralControlPlaneId
}
STATUS current
DESCRIPTION
"Controller service vmwNsxTDataCenterCentralControlPlaneId to Transport node vmwNsxTDataCenterEntityId down for at
least three minutes from Controller service's point of view.
Action required:
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
Transport node vmwNsxTDataCenterEntityId. interface via ping. If they are not pingable, check for flakiness in
network connectivity.
2. Check to see if the TCP connections are established using the netstat output to see if the
Controller service vmwNsxTDataCenterCentralControlPlaneId is listening for connections on port
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
You can check whether the Transport node is in maintenance mode via the following API:
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
When maintenance mode is set, the Transport node will not be connected to the Controller
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
check connectivity again.
Note: Please note that this alarm is not critical and should be resolved. GSS need not be
contacted for the notification of this alarm unless the alarm remains unresolved over an
extended period of time.
"
::= { vmwNsxTCommunicationFeature 11 }
vmwNsxTCommunicationControlChannelToTransportNodeDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCentralControlPlaneId
}
STATUS current
DESCRIPTION
"Controller service vmwNsxTDataCenterCentralControlPlaneId restores connection to Transport node vmwNsxTDataCenterEntityId.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 12 }
vmwNsxTCommunicationControlChannelToTransportNodeDownLong NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCentralControlPlaneId
}
STATUS current
DESCRIPTION
"Controller service vmwNsxTDataCenterCentralControlPlaneId to Transport node vmwNsxTDataCenterEntityId down for at
least 15 minutes from Controller service's point of view.
Action required:
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
Transport node vmwNsxTDataCenterEntityId. interface via ping. If they are not pingable, check for flakiness in
network connectivity.
2. Check to see if the TCP connections are established using the netstat output to see if the
Controller service vmwNsxTDataCenterCentralControlPlaneId is listening for connections on port
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
You can check whether the Transport node is in maintenance mode via the following API:
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
When maintenance mode is set, the Transport node will not be connected to the Controller
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
check connectivity again.
"
::= { vmwNsxTCommunicationFeature 19 }
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterCentralControlPlaneId
}
STATUS current
DESCRIPTION
"Controller service vmwNsxTDataCenterCentralControlPlaneId restores connection to Transport node vmwNsxTDataCenterEntityId.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 20 }
vmwNsxTCommunicationManagementChannelToManagerNodeDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
(vmwNsxTDataCenterApplianceAddress) is down for 5 minutes.
Action required:
Ensure there is network connectivity between the
Transport node vmwNsxTDataCenterTransportNodeId
and master Manager node. Also ensure no firewalls are blocking traffic
between the nodes. Ensure the messaging manager service is running on
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
If the messaging manager is not running, restart it by
invoking the command `/etc/init.d/messaging-manager restart`.
"
::= { vmwNsxTCommunicationFeature 13 }
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
(vmwNsxTDataCenterApplianceAddress) is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 14 }
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
(vmwNsxTDataCenterApplianceAddress) is down for 15 minutes.
Action required:
Ensure there is network connectivity between the
Transport node vmwNsxTDataCenterTransportNodeId
and master Manager nodes. Also ensure no firewalls are blocking traffic
between the nodes. Ensure the messaging manager service is running on
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
If the messaging manager is not running, restart it by
invoking the command `/etc/init.d/messaging-manager restart`.
"
::= { vmwNsxTCommunicationFeature 25 }
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
(vmwNsxTDataCenterApplianceAddress) is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 26 }
vmwNsxTCommunicationManagementChannelToTransportNodeDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterTransportNodeAddress
}
STATUS current
DESCRIPTION
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
(vmwNsxTDataCenterTransportNodeAddress) is down for 5 minutes.
Action required:
Ensure there is network connectivity between the Manager nodes
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
and no firewalls are blocking traffic between the nodes.
On Windows Transport nodes, ensure the nsx-proxy service is running on the
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
in the Windows PowerShell. If it is not running, restart it by
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
On all other Transport nodes, ensure the nsx-proxy service is running on the
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
If it is not running, restart it by invoking the command
`/etc/init.d/nsx-proxy restart`.
"
::= { vmwNsxTCommunicationFeature 1 }
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterTransportNodeAddress
}
STATUS current
DESCRIPTION
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
(vmwNsxTDataCenterTransportNodeAddress) is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 2 }
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterTransportNodeAddress
}
STATUS current
DESCRIPTION
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
(vmwNsxTDataCenterTransportNodeAddress) is down for 15 minutes.
Action required:
Ensure there is network connectivity between the Manager nodes
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
and no firewalls are blocking traffic between the nodes.
On Windows Transport nodes, ensure the nsx-proxy service is running on the
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
in the Windows PowerShell. If it is not running, restart it by
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
On all other Transport nodes, ensure the nsx-proxy service is running on the
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
If it is not running, restart it by invoking the command
`/etc/init.d/nsx-proxy restart`.
"
::= { vmwNsxTCommunicationFeature 5 }
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterTransportNodeAddress
}
STATUS current
DESCRIPTION
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
(vmwNsxTDataCenterTransportNodeAddress) is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 6 }
vmwNsxTCommunicationManagerClusterLatencyHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterRemoteManagerNodeId,
vmwNsxTDataCenterRemoteApplianceAddress
}
STATUS current
DESCRIPTION
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is more than 10ms for the last 5 minutes.
Action required:
Ensure there are no firewall rules blocking ping traffic between the Manager nodes.
If there are other high bandwidth servers and applications sharing the local network,
consider moving these to a different network.
"
::= { vmwNsxTCommunicationFeature 17 }
vmwNsxTCommunicationManagerClusterLatencyHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterRemoteManagerNodeId,
vmwNsxTDataCenterRemoteApplianceAddress
}
STATUS current
DESCRIPTION
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is within 10ms.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 18 }
vmwNsxTCommunicationManagerControlChannelDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeName,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"The communication between the management function and the control
function has failed on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
Action required:
1. On Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress), please invoke the
following NSX CLI command: `get service applianceproxy` to check the status
of the service periodically for 60 minutes.
2. If the service is not running for more than 60 minutes, invoke
the following NSX CLI command: `restart service applianceproxy` and recheck the
status. If the service is still down, please contact VMware support.
"
::= { vmwNsxTCommunicationFeature 3 }
vmwNsxTCommunicationManagerControlChannelDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterManagerNodeName,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"The communication between the management function and the control function
has been restored on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 4 }
vmwNsxTCommunicationManagerFQDNLookupFailure NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceFQDN
}
STATUS current
DESCRIPTION
"DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with FQDN
vmwNsxTDataCenterApplianceFQDN and the publish_fqdns flag was set.
Action required:
1. Assign correct FQDNs to all Manager nodes and verify the DNS
configuration is correct for successful lookup of all Manager
nodes' FQDNs.
2. Alternatively, disable the use of FQDNs by invoking the NSX API
PUT /api/v1/configs/management with publish_fqdns set to false in the
request body. After that calls from Transport nodes and from Federation
to Manager nodes in this cluster will use only IP addresses.
"
::= { vmwNsxTCommunicationFeature 21 }
vmwNsxTCommunicationManagerFQDNLookupFailureClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceFQDN
}
STATUS current
DESCRIPTION
"FQDN lookup succeeded for Manager node vmwNsxTDataCenterEntityId with FQDN
vmwNsxTDataCenterApplianceFQDN or the publish_fqdns flag was cleared.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 22 }
vmwNsxTCommunicationManagerFQDNReverseLookupFailure NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"Reverse DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with IP address
vmwNsxTDataCenterApplianceAddress and the publish_fqdns flag was set.
Action required:
1. Assign correct FQDNs to all Manager nodes and verify the DNS
configuration is correct for successful reverse lookup of the Manager
node's IP address.
2. Alternatively, disable the use of FQDNs by invoking the NSX API
PUT /api/v1/configs/management with publish_fqdns set to false in the
request body. After that calls from Transport nodes and from Federation
to Manager nodes in this cluster will use only IP addresses.
"
::= { vmwNsxTCommunicationFeature 23 }
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterApplianceAddress
}
STATUS current
DESCRIPTION
"Reverse DNS lookup succeeded for Manager node vmwNsxTDataCenterEntityId with IP address
vmwNsxTDataCenterApplianceAddress or the publish_fqdns flag was cleared.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTCommunicationFeature 24 }
-- **********************************************************
-- DHCP feature event notifications
-- **********************************************************
vmwNsxTDHCPFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the DHCP feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 20 }
vmwNsxTDHCPFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for DHCP feature notifications.
"
::= { vmwNsxTDHCPFeaturePrefix 0 }
vmwNsxTDHCPPoolLeaseAllocationFailed NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDHCPServerId
}
STATUS current
DESCRIPTION
"The addresses in IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId have
been exhausted. The last DHCP request has failed and future requests will
fail.
Action required:
Review the DHCP pool configuration in the NSX UI or on the Edge node where
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
Also review the current active leases on the Edge node by invoking the NSX
CLI command `get dhcp lease`. Compare the leases to the number of active
VMs. Consider reducing the lease time on the DHCP server configuration if
the number of VMs are low compared to the number of active leases. Also
consider expanding the pool range for the DHCP server by visiting the
Networking | Segments | Segment page in the NSX UI.
"
::= { vmwNsxTDHCPFeature 1 }
vmwNsxTDHCPPoolLeaseAllocationFailedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDHCPServerId
}
STATUS current
DESCRIPTION
"IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId is no longer exhausted.
A lease is successfully allocated to the last DHCP request.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDHCPFeature 2 }
vmwNsxTDHCPPoolOverloaded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDHCPServerId,
vmwNsxTDataCenterDHCPPoolUsage
}
STATUS current
DESCRIPTION
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId usage is approaching
exhaustion with vmwNsxTDataCenterDHCPPoolUsage% IPs allocated.
Action required:
Review the DHCP pool configuration in the NSX UI or on the Edge node where
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
Also review the current active leases on the Edge node by invoking the NSX
CLI command `get dhcp lease`. Compare the leases to the number of active
VMs. Consider reducing the lease time on the DHCP server configuration if
the number of VMs are low compared to the number of active leases. Also
consider expanding the pool range for the DHCP server by visiting the
Networking | Segments | Segment page in the NSX UI.
"
::= { vmwNsxTDHCPFeature 3 }
vmwNsxTDHCPPoolOverloadedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDHCPServerId
}
STATUS current
DESCRIPTION
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId has fallen below the
high usage threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDHCPFeature 4 }
-- **********************************************************
-- DistributedFirewall feature event notifications
-- **********************************************************
vmwNsxTDistributedFirewallFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the DistributedFirewall feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 31 }
vmwNsxTDistributedFirewallFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for DistributedFirewall feature notifications.
"
::= { vmwNsxTDistributedFirewallFeaturePrefix 0 }
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts. Please
review the security design for optimization. For example, use the apply-to
configuration if the rules are not applicable to the entire datacenter.
"
::= { vmwNsxTDistributedFirewallFeature 1 }
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedFirewallFeature 2 }
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterHeapType,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
View the current DFW memory usage by invoking the NSX CLI command
`get firewall thresholds` on the host. Consider re-balancing the
workloads on this host to other hosts.
"
::= { vmwNsxTDistributedFirewallFeature 3 }
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterHeapType,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedFirewallFeature 4 }
vmwNsxTDistributedFirewallDFWSessionCountHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has
reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Review the network traffic load level of the workloads on the host.
Consider re-balancing the workloads on this host to other hosts.
"
::= { vmwNsxTDistributedFirewallFeature 5 }
vmwNsxTDistributedFirewallDFWSessionCountHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedFirewallFeature 6 }
vmwNsxTDistributedFirewallDFWVmotionFailure NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName
}
STATUS current
DESCRIPTION
"The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host
vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been
disconnected.
Action required:
Check VMs on the host in NSX Manager, manually repush the DFW configuration
through NSX Manager UI. The DFW policy to be repushed can be traced by the
DFW filter vmwNsxTDataCenterEntityId. Also consider finding the VM to which the DFW filter
is attached and restart it.
"
::= { vmwNsxTDistributedFirewallFeature 7 }
vmwNsxTDistributedFirewallDFWVmotionFailureClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName
}
STATUS current
DESCRIPTION
"The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host
vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure
cleared.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedFirewallFeature 8 }
-- **********************************************************
-- DistributedIDSIPS feature event notifications
-- **********************************************************
vmwNsxTDistributedIDSIPSFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the DistributedIDSIPS feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 33 }
vmwNsxTDistributedIDSIPSFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for DistributedIDSIPS feature notifications.
"
::= { vmwNsxTDistributedIDSIPSFeaturePrefix 0 }
vmwNsxTDistributedIDSIPSMaxEventsReached NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIDSEventsCount,
vmwNsxTDataCenterMaxIDSEventsAllowed
}
STATUS current
DESCRIPTION
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
which is higher than the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
Action required:
There is no manual intervention required. A purge job will kick in automatically
every 3 minutes and delete 10% of the older records to bring the total intrusion events
count in the system to below the threshold value of 1.5 million events.
"
::= { vmwNsxTDistributedIDSIPSFeature 3 }
vmwNsxTDistributedIDSIPSMaxEventsReachedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIDSEventsCount,
vmwNsxTDataCenterMaxIDSEventsAllowed
}
STATUS current
DESCRIPTION
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
which is below the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 4 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
threshold value of 75%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 7 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the high
threshold value of 75%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 8 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
high threshold value of 85%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 21 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high
threshold value of 85%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 22 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very
high threshold value of 95%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 9 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine CPU usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the very
high threshold value of 95%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 10 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"NSX IDPS is enabled via NSX policy and IDPS rules are configured, but
NSX-IDPS engine is down.
Action required:
1. Check /var/log/nsx-syslog.log to see if there are errors reported.
2. Invoke the NSX CLI command `get ids engine status` to check
if NSX Distributed IDPS is in disabled state. If so,
invoke `/etc/init.d/nsx-idps start` to start the service.
3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running.
If not, invoke `/etc/init.d/nsx-vdpi start` to start the service.
"
::= { vmwNsxTDistributedIDSIPSFeature 13 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"NSX IDPS is in one of the cases below.
1. NSX IDPS is disabled via NSX policy.
2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and
NSX IDPS has been enabled and IDPS rules are configured
via NSX Policy.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 14 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
threshold value of 75%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 15 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold
value of 75%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 16 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
high threshold value of 85%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 17 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium
high threshold value of 85%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 18 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the
very high threshold value of 95%.
Action required:
Consider re-balancing the VM workloads on this host to other hosts.
"
::= { vmwNsxTDistributedIDSIPSFeature 19 }
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage
}
STATUS current
DESCRIPTION
"NSX-IDPS engine memory usage has reached
vmwNsxTDataCenterSystemResourceUsage%, which is below the very high
threshold value of 95%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDistributedIDSIPSFeature 20 }
-- **********************************************************
-- DNS feature event notifications
-- **********************************************************
vmwNsxTDNSFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the DNS feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 30 }
vmwNsxTDNSFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for DNS feature notifications.
"
::= { vmwNsxTDNSFeaturePrefix 0 }
vmwNsxTDNSForwarderDisabled NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterEntityId is disabled.
Action required:
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
if the DNS forwarder is in the disabled state.
2. Use NSX Policy API or Manager API to enable the DNS forwarder it
should not be in the disabled state.
"
::= { vmwNsxTDNSFeature 1 }
vmwNsxTDNSForwarderDisabledClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterEntityId is enabled.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDNSFeature 2 }
vmwNsxTDNSForwarderDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the
identified DNS Forwarder that is currently enabled.
Action required:
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
if the DNS forwarder is in down state.
2. Check /var/log/syslog to see if there are errors reported.
3. Collect a support bundle and contact the NSX support team.
"
::= { vmwNsxTDNSFeature 3 }
vmwNsxTDNSForwarderDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterEntityId is running again.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDNSFeature 4 }
vmwNsxTDNSForwarderUpstreamServerTimeout NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath,
vmwNsxTDataCenterDNSId,
vmwNsxTDataCenterDNSUpstreamIP
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response
from upstream server vmwNsxTDataCenterDNSUpstreamIP. Compute instance connectivity to
timed out FQDNs may be impacted.
Action required:
1. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
address=<address>&server_ip=vmwNsxTDataCenterDNSUpstreamIP&source_ip=<source_ip>.
This API request triggers a DNS lookup to the upstream server in the
DNS forwarder's network namespace. <address> is the IP address or FQDN
in the same domain as the upstream server. <source_ip> is an IP address
in the upstream server's zone.
If the API returns a connection timed out response, there is likely a
network error or upstream server problem. Please check why DSN lookups
are not reaching the upstream server or why the upstream server is not
returning a response. If the API response indicates the upstream server
is answering, proceed to step 2.
2. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
address=<address>.
This API request triggers a DNS lookup to the DNS forwarder. If the API
returns a valid response, the upstream server may have recovered and this
alarm should get resolved within a few minutes. If the API returns a
connection timed out response, proceed to step 3.
3. Invoke the NSX CLI command `get dns-forwarder vmwNsxTDataCenterDNSId live-debug
server-ip vmwNsxTDataCenterDNSUpstreamIP`.
This command triggers live debugging on the upstream server and logs
details and statistics showing why the DNS forwarder is not getting a
response.
"
::= { vmwNsxTDNSFeature 5 }
vmwNsxTDNSForwarderUpstreamServerTimeoutClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath,
vmwNsxTDataCenterDNSId,
vmwNsxTDataCenterDNSUpstreamIP
}
STATUS current
DESCRIPTION
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTDNSFeature 6 }
-- **********************************************************
-- Edge feature event notifications
-- **********************************************************
vmwNsxTEdgeFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Edge feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 45 }
vmwNsxTEdgeFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Edge feature notifications.
"
::= { vmwNsxTEdgeFeaturePrefix 0 }
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
}
STATUS current
DESCRIPTION
"The Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not
match the policy intent configuration. The Edge node configuration visible to user
on UI or API is not same as what is realized. The realized Edge node changes made by
user outside of NSX Manager are shown in the details of this alarm and any edits in
UI or API will overwrite the realized configuration. Fields that differ for Edge node
settings and vSphere configuration are listed in runtime data vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
Action required:
Please review the node settings and vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
Please follow one of following actions to resolve alarm -
1. Manually update Edge Transport Node setting Policy intent using
API : PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
2. Accept intent or vSphere realized Edge node configuration or realized
Edge node settings for this Edge Transport Node through Edge Transport Node
resolver to resolve this alarm.
3. Resolve alarm by accepting the Edge node settings and vSphere realized configuration
using refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
"
::= { vmwNsxTEdgeFeature 1 }
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeFeature 2 }
vmwNsxTEdgeEdgeNodeSettingsMismatch NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
}
STATUS current
DESCRIPTION
"The Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy
intent configuration. The Edge node configuration visible to user on
UI or API is not same as what is realized. The realized Edge node changes
made by user outside of NSX Manager are shown in the details of this alarm
and any edits in UI or API will overwrite the realized configuration.
Fields that differ for the Edge node are listed in runtime data
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
Action required:
Please review the node settings of this Edge transport node vmwNsxTDataCenterEntityId.
Please follow one of following actions to resolve alarm -
1. Manually update Edge transport node setting Policy intent
using API - PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
2. Accept intent or realized Edge node settings for this Edge transport node
through Edge transport node resolver to resolve this alarm.
3. Resolve alarm by accepting the Edge node settings configuration using
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
"
::= { vmwNsxTEdgeFeature 3 }
vmwNsxTEdgeEdgeNodeSettingsMismatchClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeFeature 4 }
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
}
STATUS current
DESCRIPTION
"The Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy
intent configuration. The Edge node configuration visible to user on UI or API
is not same as what is realized. The realized Edge node changes made by user
outside of NSX Manager are shown in the details of this alarm and any edits
in UI or API will overwrite the realized configuration. Fields that differ for
the Edge node are listed in runtime data vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
Action required:
Please review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
Please follow one of following actions to resolve alarm -
1. Accept intent or vSphere realized Edge node configuration for this Edge Transport Node
through Edge Transport Node resolver to resolve this alarm.
2. Resolve alarm by accepting the Edge node vSphere realized configuration using
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
"
::= { vmwNsxTEdgeFeature 5 }
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeFeature 6 }
vmwNsxTEdgeEdgevSphereLocationMismatch NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgevSphereLocationMismatchReason
}
STATUS current
DESCRIPTION
"The Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration
on vSphere does not match the policy intent configuration. The Edge node configuration visible to
user on UI or API is not same as what is realized. The realized Edge node changes made by user outside
of NSX Manager are shown in the details of this alarm. Fields that differ for the Edge node are listed
in runtime data vmwNsxTDataCenterEdgevSphereLocationMismatchReason
Action required:
Please review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
Please follow one of following actions to resolve alarm -
1. Resolve alarm by accepting the Edge node vSphere realized config using
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
2. If you want to return to the previous location please use
NSX Redeploy API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=redeploy.
vMotion back to the original host is not supported.
"
::= { vmwNsxTEdgeFeature 7 }
vmwNsxTEdgeEdgevSphereLocationMismatchClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeFeature 8 }
-- **********************************************************
-- EdgeHealth feature event notifications
-- **********************************************************
vmwNsxTEdgeHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the EdgeHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 2 }
vmwNsxTEdgeHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for EdgeHealth feature notifications.
"
::= { vmwNsxTEdgeHealthFeaturePrefix 0 }
vmwNsxTEdgeHealthDatapathThreadDeadlocked NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeThreadName
}
STATUS current
DESCRIPTION
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is deadlocked.
Action required:
Restart the dataplane service by invoking the NSX CLI command `restart service dataplane`.
"
::= { vmwNsxTEdgeHealthFeature 45 }
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeThreadName
}
STATUS current
DESCRIPTION
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is free from deadlock.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 46 }
vmwNsxTEdgeHealthEdgeCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this Edge
node. Consider adjusting the Edge appliance form factor size or rebalancing
services to other Edge nodes for the applicable workload.
"
::= { vmwNsxTEdgeHealthFeature 1 }
vmwNsxTEdgeHealthEdgeCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 2 }
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this Edge
node. Consider adjusting the Edge appliance form factor size or rebalancing
services to other Edge nodes for the applicable workload.
"
::= { vmwNsxTEdgeHealthFeature 3 }
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 4 }
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Failed to enable the datapath on the Edge node after three attempts.
Action required:
Ensure the Edge node's connectivity to the Manager node is healthy. From
the Edge node's NSX CLI, invoke the command `get services` to check the
health of services. If the dataplane service is stopped, invoke the
command `start service dataplane` to start it.
"
::= { vmwNsxTEdgeHealthFeature 21 }
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Datapath on the Edge node has been successfully enabled.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 22 }
vmwNsxTEdgeHealthEdgeDatapathCPUHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDatapathResourceUsage
}
STATUS current
DESCRIPTION
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the high
threshold for at least two minutes.
Action required:
Review the CPU statistics on the Edge node by invoking the NSX CLI command
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
usage is expected with higher packet rates. Consider increasing the Edge
appliance form factor size and rebalancing services on this Edge node to
other Edge nodes in the same cluster or other Edge clusters.
"
::= { vmwNsxTEdgeHealthFeature 17 }
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
high threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 18 }
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDatapathResourceUsage
}
STATUS current
DESCRIPTION
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the very high
threshold for at least two minutes.
Action required:
Review the CPU statistics on the Edge node by invoking the NSX CLI command
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
usage is expected with higher packet rates. Consider increasing the Edge
appliance form factor size and rebalancing services on this Edge node to
other Edge nodes in the same cluster or other Edge clusters.
"
::= { vmwNsxTEdgeHealthFeature 19 }
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
very high threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 20 }
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeCryptoDrvName
}
STATUS current
DESCRIPTION
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is down.
Action required:
Upgrade the Edge node as needed.
"
::= { vmwNsxTEdgeHealthFeature 23 }
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeCryptoDrvName
}
STATUS current
DESCRIPTION
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 24 }
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterMempoolName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Log in as the root user and invoke the command
`edge-appctl -t /var/run/vmware/edge/dpd.ctl mempool/show` and
`edge-appctl -t /var/run/vmware/edge/dpd.ctl memory/show malloc_heap` to
check DPDK memory usage.
"
::= { vmwNsxTEdgeHealthFeature 25 }
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterMempoolName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 26 }
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterNICThroughput,
vmwNsxTDataCenterNICThroughputThreshold
}
STATUS current
DESCRIPTION
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
Action required:
Examine the traffic thoughput levels on the NIC and determine whether
configuration changes are needed. The 'get dataplane thoughput <seconds>'
command can be used to monitor throughput.
"
::= { vmwNsxTEdgeHealthFeature 49 }
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterNICThroughput,
vmwNsxTDataCenterNICThroughputThreshold
}
STATUS current
DESCRIPTION
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
is below the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 50 }
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterNICThroughput,
vmwNsxTDataCenterNICThroughputThreshold
}
STATUS current
DESCRIPTION
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
Action required:
Examine the traffic thoughput levels on the NIC and determine whether
configuration changes are needed. The 'get dataplane thoughput <seconds>'
command can be used to monitor throughput.
"
::= { vmwNsxTEdgeHealthFeature 51 }
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterNICThroughput,
vmwNsxTDataCenterNICThroughputThreshold
}
STATUS current
DESCRIPTION
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
is below the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 52 }
vmwNsxTEdgeHealthEdgeDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine the partition with high usage and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTEdgeHealthFeature 9 }
vmwNsxTEdgeHealthEdgeDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 10 }
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine the partition with high usage and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTEdgeHealthFeature 11 }
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the
very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 12 }
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDatapathResourceUsage
}
STATUS current
DESCRIPTION
"Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterDatapathResourceUsage% which is above the high threshold
for over two minutes.
Action required:
Log in as the root user and invoke the command
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/show` and check
if neigh cache usage is normal. If it is normal, invoke the command
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/set_param max_entries`
to increase the ARP table size.
"
::= { vmwNsxTEdgeHealthFeature 27 }
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Global arp table usage on Edge node vmwNsxTDataCenterEntityId has reached
below the high threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 28 }
vmwNsxTEdgeHealthEdgeMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this Edge
node. Consider adjusting the Edge appliance form factor size or rebalancing
services to other Edge nodes for the applicable workload.
"
::= { vmwNsxTEdgeHealthFeature 5 }
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 6 }
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this Edge
node. Consider adjusting the Edge appliance form factor size or rebalancing
services to other Edge nodes for the applicable workload.
"
::= { vmwNsxTEdgeHealthFeature 7 }
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 8 }
vmwNsxTEdgeHealthEdgeNICLinkStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName
}
STATUS current
DESCRIPTION
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is down.
Action required:
On the Edge node confirm if the NIC link is physically down by invoking
the NSX CLI command `get interfaces`. If it is down, verify the cable
connection.
"
::= { vmwNsxTEdgeHealthFeature 29 }
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName
}
STATUS current
DESCRIPTION
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 30 }
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
vmwNsxTDataCenterRxMisses,
vmwNsxTDataCenterRxProcessed
}
STATUS current
DESCRIPTION
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer has overflowed by
vmwNsxTDataCenterRxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
The missed packet count is vmwNsxTDataCenterRxMisses and processed packet count
is vmwNsxTDataCenterRxProcessed.
Action required:
Invoke the NSX CLI command `get dataplane cpu stats`, and check
1. If cpu usage is high, i.e., > 90%, then take a packet capture on
the interface using the command `start capture interface
<interface-name> direction input` or `start capture interface
<interface-name> direction input core <core-id>` (to capture
packets ingressing on specific core whose usage is high).
Then analyze the capture to see if there are majority of
fragmented packets or ipsec packets. If yes, then it is expected
behavior. If not probably datapath is stuck processing other bookkeeping
operations and if alarm lasts or more than 2-3 min, contact VMware Support.
2. If cpu usage is not high, i.e., < 90%, then check if rx pps is high
using the command `get dataplane cpu stats` (just to make sure the
traffic rate is increasing). Then increase the ring size by 1024
using the command `set dataplane ring-size rx <ring-size>`.
NOTE - The continuous increase of ring size by 1024 factor can lead
to some performance issue due to cache line thrashing internally.
If even after increasing the ring size, the issue persists then
it is an indication that edge needs a larger form factor deployment
to accommodate the traffic.
3. If the alarm keeps on flapping i.e., triggers and resolves very soon,
then it is due to bursty traffic. In this case check if rx pps as
described above, if it is not high during the alarm active period
then contact VMware Support. If pps is high it confirms bursty traffic.
Consider suppressing the alarm.
NOTE - There is no specific benchmark to decide what is regarded as a
high pps value. It depends on infrastructure and type of traffic.
The comparison can be made by noting down when alarm is inactive and
when it is active.
"
::= { vmwNsxTEdgeHealthFeature 31 }
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName
}
STATUS current
DESCRIPTION
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer usage on Edge node
vmwNsxTDataCenterEntityId is no longer overflowing.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 32 }
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
vmwNsxTDataCenterTxMisses,
vmwNsxTDataCenterTxProcessed
}
STATUS current
DESCRIPTION
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer has overflowed by
vmwNsxTDataCenterTxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
The missed packet count is vmwNsxTDataCenterTxMisses and processed packet count
is vmwNsxTDataCenterTxProcessed.
Action required:
1. If a lot of VMs are accommodated along with edge by the hypervisor
then edge VM might not get time to run, hence the packets might
not be retrieved by hypervisor. Then probably migrating the edge VM
to a host with fewer VMs.
2. Increase the ring size by 1024 using the command `set dataplane
ring-size tx <ring-size>`. If even after increasing the ring size,
the issue persists then contact VMware Support as the ESX side
transmit ring buffer might be of lower value. If there is no
issue on ESX side, it indicates the edge needs to be scaled to
a larger form factor deployment to accommodate the traffic.
3. If the alarm keeps on flapping, i.e., triggers and resolves very soon,
then it is due to bursty traffic. In this case check if tx pps using
the command `get dataplane cpu stats`. If it is not high during the
alarm active period then contact VMware Support.
If pps is high it confirms bursty traffic. Consider suppressing the
alarm.
NOTE - There is no specific benchmark to decide what is regarded as a
high pps value. It depends on infrastructure and type of traffic.
The comparison can be made by noting down when alarm is inactive and
when it is active.
"
::= { vmwNsxTEdgeHealthFeature 33 }
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeNICName
}
STATUS current
DESCRIPTION
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer usage on Edge node
vmwNsxTDataCenterEntityId is no longer overflowing.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 34 }
vmwNsxTEdgeHealthFailureDomainDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"All members of failure domain vmwNsxTDataCenterTransportNodeId are down.
Action required:
1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, check the connectivity
to the management and control planes by invoking the NSX CLI command
`get managers` and `get controllers`.
2. Invoke the NSX CLI command `get interface eth0` to check the management
interface status.
3. Invoke the CLI `get services` to check the core services status like
dataplane/local-controller/nestdb/router, etc.
4. Inspect the /var/log/syslog to find the suspecting error.
5. Reboot the Edge node.
"
::= { vmwNsxTEdgeHealthFeature 53 }
vmwNsxTEdgeHealthFailureDomainDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"All members of failure domain vmwNsxTDataCenterTransportNodeId are reachable.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 54 }
vmwNsxTEdgeHealthStorageError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName
}
STATUS current
DESCRIPTION
"The following disk partitions on the Edge node are in
read-only mode: vmwNsxTDataCenterDiskPartitionName
Action required:
Examine the read-only partition to see if reboot resolves the issue
or the disk needs to be replaced. Contact GSS for more information.
"
::= { vmwNsxTEdgeHealthFeature 37 }
vmwNsxTEdgeHealthStorageErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName
}
STATUS current
DESCRIPTION
"The following disk partitions on the Edge node have recovered from
read-only mode: vmwNsxTDataCenterDiskPartitionName
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEdgeHealthFeature 38 }
-- **********************************************************
-- EndpointProtection feature event notifications
-- **********************************************************
vmwNsxTEndpointProtectionFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the EndpointProtection feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 13 }
vmwNsxTEndpointProtectionFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for EndpointProtection feature notifications.
"
::= { vmwNsxTEndpointProtectionFeaturePrefix 0 }
vmwNsxTEndpointProtectionEAMStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down.
Action required:
Start the ESX Agent Manager (EAM) service. SSH into vCenter and invoke
the command `service vmware-eam start`.
"
::= { vmwNsxTEndpointProtectionFeature 1 }
vmwNsxTEndpointProtectionEAMStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up
or compute manager vmwNsxTDataCenterEntityId has been removed.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEndpointProtectionFeature 2 }
vmwNsxTEndpointProtectionPartnerChannelDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
is down.
Action required:
Refer to https://kb.vmware.com/s/article/85844 and make sure
that Partner SVM vmwNsxTDataCenterEntityId is re-connected to the host module.
"
::= { vmwNsxTEndpointProtectionFeature 3 }
vmwNsxTEndpointProtectionPartnerChannelDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTEndpointProtectionFeature 4 }
-- **********************************************************
-- Federation feature event notifications
-- **********************************************************
vmwNsxTFederationFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Federation feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 32 }
vmwNsxTFederationFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Federation feature notifications.
"
::= { vmwNsxTFederationFeaturePrefix 0 }
vmwNsxTFederationGMToGMLatencyWarning NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"Latency is higher than expected between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
Action required:
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity.
"
::= { vmwNsxTFederationFeature 17 }
vmwNsxTFederationGMToGMLatencyWarningClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath
}
STATUS current
DESCRIPTION
"Latency is below expected levels between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 18 }
vmwNsxTFederationGMToGMSplitBrain NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterActiveGlobalManagers
}
STATUS current
DESCRIPTION
"Multiple Global Manager nodes are active: vmwNsxTDataCenterActiveGlobalManagers. Only one Global Manager node must be active
at any time.
Action required:
Configure only one Global Manager node as active and all other Global Manager nodes as standby.
"
::= { vmwNsxTFederationFeature 9 }
vmwNsxTFederationGMToGMSplitBrainClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterActiveGlobalManager
}
STATUS current
DESCRIPTION
"Global Manager node vmwNsxTDataCenterActiveGlobalManager is the only active Global Manager node now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 10 }
vmwNsxTFederationGMToGMSynchronizationError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath cannot
synchronize for more than 5 minutes.
Action required:
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
"
::= { vmwNsxTFederationFeature 19 }
vmwNsxTFederationGMToGMSynchronizationErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath
}
STATUS current
DESCRIPTION
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 20 }
vmwNsxTFederationGMToGMSynchronizationWarning NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath can not synchronize.
Action required:
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
"
::= { vmwNsxTFederationFeature 21 }
vmwNsxTFederationGMToGMSynchronizationWarningClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterToGMPath
}
STATUS current
DESCRIPTION
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 22 }
vmwNsxTFederationGMToLMLatencyWarning NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterLatencyValue,
vmwNsxTDataCenterLatencyThreshold
}
STATUS current
DESCRIPTION
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
vmwNsxTDataCenterLatencyValue which is above the threshold value of vmwNsxTDataCenterLatencyThreshold.
Action required:
1. Check the network connectivity between remote site and local site via ping.
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
3. Check /var/log/async-replicator/ar.log to see if there are errors reported.
"
::= { vmwNsxTFederationFeature 27 }
vmwNsxTFederationGMToLMLatencyWarningClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterLatencyValue,
vmwNsxTDataCenterLatencyThreshold
}
STATUS current
DESCRIPTION
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
vmwNsxTDataCenterLatencyValue which below the threshold value of vmwNsxTDataCenterLatencyThreshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 28 }
vmwNsxTFederationGMToLMSynchronizationError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterFlowIdentifier,
vmwNsxTDataCenterSyncIssueReason
}
STATUS current
DESCRIPTION
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
failed for the vmwNsxTDataCenterFlowIdentifier for an extended period. Reason: vmwNsxTDataCenterSyncIssueReason.
Action required:
1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported. 5. Collect a support bundle and contact the NSX support team.
"
::= { vmwNsxTFederationFeature 23 }
vmwNsxTFederationGMToLMSynchronizationErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterFlowIdentifier
}
STATUS current
DESCRIPTION
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 24 }
vmwNsxTFederationGMToLMSynchronizationWarning NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterFlowIdentifier,
vmwNsxTDataCenterSyncIssueReason
}
STATUS current
DESCRIPTION
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the
vmwNsxTDataCenterFlowIdentifier. Reason: vmwNsxTDataCenterSyncIssueReason
Action required:
1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported.
"
::= { vmwNsxTFederationFeature 25 }
vmwNsxTFederationGMToLMSynchronizationWarningClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterFlowIdentifier
}
STATUS current
DESCRIPTION
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 26 }
vmwNsxTFederationLMRestoreWhileConfigImportInProgress NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId
}
STATUS current
DESCRIPTION
"Config import from site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is in progress. However site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is restored
from backup by the administrator leaving it in an inconsistent state.
Action required:
1. Log in to NSX Global Manager appliance CLI.
2. Switch to root.
3. Invoke the NSX API DELETE http://localhost:64440/gm/api/v1/infra/sites/<site-name>/onboarding/status in local mode,
this will delete site on-boarding status for Global Manager.
4. Re-initiate config on-boarding again.
"
::= { vmwNsxTFederationFeature 31 }
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId
}
STATUS current
DESCRIPTION
"Config inconsistency at site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is resolved.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 32 }
vmwNsxTFederationLmToLmSynchronizationError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
failed for more than 5 minutes.
Action required:
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
state between the remote locations. If a remote location is connected but not synchronized,
it is possible that the location is still in the process of master resolution. In
this case, wait for around 10 seconds and try invoking the CLI again to
check for the state of the remote location. If a location is disconnected, try the next
step.
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
check for flakiness in WAN connectivity. If there are no physical network
connectivity issues, try the next step.
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
communication errors. In addition, also look for errors being logged by the
nsx-appl-proxy subcomponent within /var/log/syslog.
"
::= { vmwNsxTFederationFeature 3 }
vmwNsxTFederationLmToLmSynchronizationErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"Remote sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 4 }
vmwNsxTFederationLmToLmSynchronizationWarning NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed.
Action required:
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
state between the remote locations. If a remote location is connected but not synchronized,
it is possible that the location is still in the process of master resolution. In
this case, wait for around 10 seconds and try invoking the CLI again to
check for the state of the remote location. If a location is disconnected, try the next
step.
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
check for flakiness in WAN connectivity. If there are no physical network
connectivity issues, try the next step.
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
communication errors. In addition, also look for errors being logged by the
nsx-appl-proxy subcomponent within /var/log/syslog.
"
::= { vmwNsxTFederationFeature 5 }
vmwNsxTFederationLmToLmSynchronizationWarningClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId
}
STATUS current
DESCRIPTION
"Remote locations vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 6 }
vmwNsxTFederationQueueOccupancyThresholdExceeded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterQueueName,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterQueueSize,
vmwNsxTDataCenterQueueSizeThreshold
}
STATUS current
DESCRIPTION
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
has reached size vmwNsxTDataCenterQueueSize which is at or above the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
Action required:
Queue size can exceed threshold due to communication issue with remote site or an overloaded system.
Please check system performance and /var/log/async-replicator/ar.log to see if there are any errors reported.
"
::= { vmwNsxTFederationFeature 29 }
vmwNsxTFederationQueueOccupancyThresholdExceededClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterQueueName,
vmwNsxTDataCenterSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterQueueSize,
vmwNsxTDataCenterQueueSizeThreshold
}
STATUS current
DESCRIPTION
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
has reached size vmwNsxTDataCenterQueueSize which is below the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 30 }
vmwNsxTFederationRtepBGPDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterBGPSourceIP,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterBGPNeighborIP,
vmwNsxTDataCenterFailureReason
}
STATUS current
DESCRIPTION
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is down.
Reason: vmwNsxTDataCenterFailureReason.
Action required:
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node.
2. Switch to REMOTE_TUNNEL_VRF context.
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
to get the BGP neighbor status.
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
to the interface with name remote-tunnel-endpoint.
6. Check if the ping is working successfully between assigned RTEP IP address (vmwNsxTDataCenterBGPSourceIP) and the
remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP.
7. Check /var/log/syslog for any errors related to BGP.
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
configuration on the edge node.
This will update the RTEP IP assigned to the affected edge node.
If the reason indicates `Edge is not ready`, check why edge is not in good state.
1. Invoke the NSX CLI command `get edge-cluster status` to check reason why edge might be down.
2. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
3. Check any edge health related alarms to get more information.
"
::= { vmwNsxTFederationFeature 1 }
vmwNsxTFederationRtepBGPDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterBGPSourceIP,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterBGPNeighborIP
}
STATUS current
DESCRIPTION
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is established.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 2 }
vmwNsxTFederationRtepConnectivityLost NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterRemoteSiteName
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterTransportNodeName lost RTEP (Remote Tunnel Endpoint) connectivity
with remote location vmwNsxTDataCenterRemoteSiteName.
Action required:
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node vmwNsxTDataCenterTransportNodeName.
2. Switch to REMOTE_TUNNEL_VRF context.
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
to get the BGP neighbor status.
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
to the interface with name remote-tunnel-endpoint.
6. Check if the ping is working successfully between assigned RTEP IP address and the RTEP IP addresses
on the remote location vmwNsxTDataCenterRemoteSiteName.
7. Check /var/log/syslog for any errors related to BGP.
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
configuration on the edge node.
This will update the RTEP IP assigned to the affected edge node vmwNsxTDataCenterTransportNodeName.
"
::= { vmwNsxTFederationFeature 7 }
vmwNsxTFederationRtepConnectivityLostClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterRemoteSiteName
}
STATUS current
DESCRIPTION
"Edge node vmwNsxTDataCenterTransportNodeName has restored RTEP (Remote Tunnel Endpoint) connectivity
with remote location vmwNsxTDataCenterRemoteSiteName.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTFederationFeature 8 }
-- **********************************************************
-- GatewayFirewall feature event notifications
-- **********************************************************
vmwNsxTGatewayFirewallFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the GatewayFirewall feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 39 }
vmwNsxTGatewayFirewallFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for GatewayFirewall feature notifications.
"
::= { vmwNsxTGatewayFirewallFeaturePrefix 0 }
vmwNsxTGatewayFirewallICMPFlowCountExceeded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallICMPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for ICMP traffic on logical
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usage for ICMP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 21 }
vmwNsxTGatewayFirewallICMPFlowCountExceededClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 22 }
vmwNsxTGatewayFirewallICMPFlowCountHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallICMPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usege for ICMP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 23 }
vmwNsxTGatewayFirewallICMPFlowCountHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for ICMP on logical router
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 24 }
vmwNsxTGatewayFirewallIPFlowCountExceeded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallIPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for IP traffic on logical router vmwNsxTDataCenterEntityId has
reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usage for IP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 25 }
vmwNsxTGatewayFirewallIPFlowCountExceededClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 26 }
vmwNsxTGatewayFirewallIPFlowCountHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallIPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for IP on logical router vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usege for IP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 27 }
vmwNsxTGatewayFirewallIPFlowCountHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for non IP flows on logical router
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 28 }
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for TCP half-open traffic on logical
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usage for TCP half-open flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 29 }
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 30 }
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for TCP on logical router vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usege for TCP half-open flow.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 31 }
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for TCP half-open on logical router
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 32 }
vmwNsxTGatewayFirewallUDPFlowCountExceeded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallUDPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for UDP traffic on logical
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usage for UDP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 33 }
vmwNsxTGatewayFirewallUDPFlowCountExceededClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
below the high threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 34 }
vmwNsxTGatewayFirewallUDPFlowCountHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterFirewallUDPFlowUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> interface stats | json` by using
right interface uuid and check flow table usege for UDP flows.
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
"
::= { vmwNsxTGatewayFirewallFeature 35 }
vmwNsxTGatewayFirewallUDPFlowCountHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Gateway firewall flow table usage for UDP on logical router
vmwNsxTDataCenterEntityId has reached below the high threshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTGatewayFirewallFeature 36 }
-- **********************************************************
-- HighAvailability feature event notifications
-- **********************************************************
vmwNsxTHighAvailabilityFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the HighAvailability feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 21 }
vmwNsxTHighAvailabilityFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for HighAvailability feature notifications.
"
::= { vmwNsxTHighAvailabilityFeaturePrefix 0 }
vmwNsxTHighAvailabilityTier0GatewayFailover NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterPreviousGatewayState,
vmwNsxTDataCenterCurrentGatewayState,
vmwNsxTDataCenterServiceRouterId
}
STATUS current
DESCRIPTION
"The tier0 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
Action required:
Invoke the NSX CLI command `get logical-router <service_router_id>` to
identify the tier0 service-router vrf ID. Switch to the vrf context by
invoking `vrf <vrf-id>` then invoke `get high-availability status`
to determine the service that is down.
"
::= { vmwNsxTHighAvailabilityFeature 9 }
vmwNsxTHighAvailabilityTier0GatewayFailoverClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The tier0 gateway vmwNsxTDataCenterEntityId is now up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTHighAvailabilityFeature 10 }
vmwNsxTHighAvailabilityTier1GatewayFailover NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterPreviousGatewayState,
vmwNsxTDataCenterCurrentGatewayState,
vmwNsxTDataCenterServiceRouterId
}
STATUS current
DESCRIPTION
"The tier1 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
Action required:
Invoke the NSX CLI command `get logical-router <service_router_id>` to
identify the tier1 service-router vrf ID. Switch to the vrf context by
invoking `vrf <vrf-id>` then invoke `get high-availability status`
to determine the service that is down.
"
::= { vmwNsxTHighAvailabilityFeature 11 }
vmwNsxTHighAvailabilityTier1GatewayFailoverClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The tier1 gateway vmwNsxTDataCenterEntityId is now up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTHighAvailabilityFeature 12 }
-- **********************************************************
-- IdentityFirewall feature event notifications
-- **********************************************************
vmwNsxTIdentityFirewallFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the IdentityFirewall feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 36 }
vmwNsxTIdentityFirewallFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for IdentityFirewall feature notifications.
"
::= { vmwNsxTIdentityFirewallFeaturePrefix 0 }
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLDAPServer
}
STATUS current
DESCRIPTION
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost.
Action required:
Please check
1. The LDAP server is reachable from NSX nodes.
2. The LDAP server details are configured correctly in NSX.
3. The LDAP server is running correctly.
4. There are no firewalls blocking access between the LDAP server
and NSX nodes.
Afer the issue is fixed, use TEST CONNECTION in NSX UI under
Identity Firewall AD to test the connection.
"
::= { vmwNsxTIdentityFirewallFeature 1 }
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLDAPServer
}
STATUS current
DESCRIPTION
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIdentityFirewallFeature 2 }
vmwNsxTIdentityFirewallErrorInDeltaSync NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDirectoryDomain
}
STATUS current
DESCRIPTION
"Errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
Action required:
1. Check if there are any connectivity to LDAP server lost alarms.
2. Find the error details in /var/log/syslog. Around the alarm trigger
time, search for text: Error happened when synchronize LDAP objects.
3. Check with AD administrator if there are any recent AD changes which
may cause the errors.
4. If the errors persist, collect the technical support bundle and
contact VMware technical support.
"
::= { vmwNsxTIdentityFirewallFeature 3 }
vmwNsxTIdentityFirewallErrorInDeltaSyncClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDirectoryDomain
}
STATUS current
DESCRIPTION
"No errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIdentityFirewallFeature 4 }
-- **********************************************************
-- InfrastructureCommunication feature event notifications
-- **********************************************************
vmwNsxTInfrastructureCommunicationFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the InfrastructureCommunication feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 7 }
vmwNsxTInfrastructureCommunicationFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for InfrastructureCommunication feature notifications.
"
::= { vmwNsxTInfrastructureCommunicationFeaturePrefix 0 }
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The overall tunnel status of Edge node vmwNsxTDataCenterEntityId is down.
Action required:
Invoke the NSX CLI command `get tunnel-ports` to get all tunnel ports,
then check each tunnel's stats by invoking NSX CLI command
`get tunnel-port <UUID> stats` to check if there are any drops. Also
check /var/log/syslog if there are tunnel related errors.
"
::= { vmwNsxTInfrastructureCommunicationFeature 17 }
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The tunnels of Edge node vmwNsxTDataCenterEntityId have been restored.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTInfrastructureCommunicationFeature 18 }
-- **********************************************************
-- InfrastructureService feature event notifications
-- **********************************************************
vmwNsxTInfrastructureServiceFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the InfrastructureService feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 19 }
vmwNsxTInfrastructureServiceFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for InfrastructureService feature notifications.
"
::= { vmwNsxTInfrastructureServiceFeaturePrefix 0 }
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeServiceName,
vmwNsxTDataCenterPreviousServiceState,
vmwNsxTDataCenterCurrentServiceState,
vmwNsxTDataCenterServiceDownReason
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
to vmwNsxTDataCenterCurrentServiceState.
vmwNsxTDataCenterServiceDownReason
Action required:
On the Edge node, verify the service hasn't exited due to an error by
looking for core files in the /var/log/core directory. In addition,
invoke the NSX CLI command `get services` to confirm whether the service
is stopped. If so, invoke `start service <service-name>` to restart the
service.
"
::= { vmwNsxTInfrastructureServiceFeature 1 }
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeServiceName,
vmwNsxTDataCenterPreviousServiceState,
vmwNsxTDataCenterCurrentServiceState
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
to vmwNsxTDataCenterCurrentServiceState.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTInfrastructureServiceFeature 2 }
vmwNsxTInfrastructureServiceEdgeServiceStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeServiceName,
vmwNsxTDataCenterServiceDownReason
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterEdgeServiceName is down for at least one minute.
vmwNsxTDataCenterServiceDownReason
Action required:
On the Edge node, verify the service hasn't exited due to an error by
looking for core files in the /var/log/core directory. In addition,
invoke the NSX CLI command `get services` to confirm whether the service
is stopped. If so, invoke `start service <service-name>` to restart the
service.
"
::= { vmwNsxTInfrastructureServiceFeature 3 }
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEdgeServiceName
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterEdgeServiceName is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTInfrastructureServiceFeature 4 }
vmwNsxTInfrastructureServiceServiceStatusUnknown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceName
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterServiceName has been unresponsive for 10 seconds.
Action required:
Verify vmwNsxTDataCenterServiceName service is still running by invoking `/etc/init.d/vmwNsxTDataCenterServiceName status`.
If the service is reported as running, it may need to get restarted which can be done by
`/etc/init.d/vmwNsxTDataCenterServiceName restart`. Rerun the status command to verify the service is now
running. If the script `/etc/init.d/vmwNsxTDataCenterServiceName` is unavailable, please try invoking
`systemctl vmwNsxTDataCenterServiceName status` and restart by `systemctl vmwNsxTDataCenterServiceName restart` with root
priviledges. If restarting the service does not resolve the issue or if the issue reoccurs after
a successful restart, please contact VMware Support.
"
::= { vmwNsxTInfrastructureServiceFeature 7 }
vmwNsxTInfrastructureServiceServiceStatusUnknownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceName
}
STATUS current
DESCRIPTION
"The service vmwNsxTDataCenterServiceName is responsive again.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTInfrastructureServiceFeature 8 }
-- **********************************************************
-- IntelligenceCommunication feature event notifications
-- **********************************************************
vmwNsxTIntelligenceCommunicationFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the IntelligenceCommunication feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 9 }
vmwNsxTIntelligenceCommunicationFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for IntelligenceCommunication feature notifications.
"
::= { vmwNsxTIntelligenceCommunicationFeaturePrefix 0 }
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
the Intelligence node's messaging broker. Data collection is affected.
Action required:
Restart the messaging service if it is not running in the Intelligence
node. Resolve the network connection failure between the Transport node
flow exporter and the Intelligence node.
"
::= { vmwNsxTIntelligenceCommunicationFeature 7 }
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
the Intelligence node's messaging broker.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceCommunicationFeature 8 }
-- **********************************************************
-- IntelligenceHealth feature event notifications
-- **********************************************************
vmwNsxTIntelligenceHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the IntelligenceHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 6 }
vmwNsxTIntelligenceHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for IntelligenceHealth feature notifications.
"
::= { vmwNsxTIntelligenceHealthFeaturePrefix 0 }
vmwNsxTIntelligenceHealthCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Use the top command to check which processes have the most CPU usages, and
then check /var/log/syslog and these processes' local logs to see if there
are any outstanding errors to be resolved.
"
::= { vmwNsxTIntelligenceHealthFeature 41 }
vmwNsxTIntelligenceHealthCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 42 }
vmwNsxTIntelligenceHealthCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Use the top command to check which processes have the most CPU usages, and
then check /var/log/syslog and these processes' local logs to see if there
are any outstanding errors to be resolved.
"
::= { vmwNsxTIntelligenceHealthFeature 43 }
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 44 }
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition /data on Intelligence node
vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Stop NSX intelligence data collection until the disk usage is below
the threshold. Examine disk partition /data and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTIntelligenceHealthFeature 45 }
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition /data on Intelligence node
vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 46 }
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition /data on Intelligence node
vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Stop NSX intelligence data collection until the disk usage is below
the threshold. In the NSX UI, navigate to System | Appliances | NSX
Intelligence Appliance. Then click ACTONS, Stop Collecting Data.
"
::= { vmwNsxTIntelligenceHealthFeature 47 }
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition /data on Intelligence node
vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 48 }
vmwNsxTIntelligenceHealthDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTIntelligenceHealthFeature 49 }
vmwNsxTIntelligenceHealthDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 50 }
vmwNsxTIntelligenceHealthDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTIntelligenceHealthFeature 51 }
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 52 }
vmwNsxTIntelligenceHealthMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Use the top command to check which processes have the most memory usages,
and then check /var/log/syslog and these processes' local logs to see if
there are any outstanding errors to be resolved.
"
::= { vmwNsxTIntelligenceHealthFeature 53 }
vmwNsxTIntelligenceHealthMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 54 }
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Use the top command to check which processes have the most memory usages,
and then check /var/log/syslog and these processes' local logs to see if
there are any outstanding errors to be resolved.
"
::= { vmwNsxTIntelligenceHealthFeature 55 }
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 56 }
vmwNsxTIntelligenceHealthNodeStatusDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceName,
vmwNsxTDataCenterIntelligenceNodeId
}
STATUS current
DESCRIPTION
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is degraded.
Action required:
Invoke the NSX API GET /napp/api/v1/platform/monitor/category/health to
check which specific pod is down and the reason behind it. Invoke the following
CLI command to restart the degraded service:
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
"
::= { vmwNsxTIntelligenceHealthFeature 57 }
vmwNsxTIntelligenceHealthNodeStatusDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceName,
vmwNsxTDataCenterIntelligenceNodeId
}
STATUS current
DESCRIPTION
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 58 }
vmwNsxTIntelligenceHealthStorageLatencyHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
Action required:
Transient high storage latency may happen due to spike of I/O requests.
If storage latency remains high for more than 30 minutes,
consider deploying NSX Intelligence appliance in a low latency disk,
or not sharing the same storage device with other VMs.
"
::= { vmwNsxTIntelligenceHealthFeature 63 }
vmwNsxTIntelligenceHealthStorageLatencyHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIntelligenceHealthFeature 64 }
-- **********************************************************
-- IPAM feature event notifications
-- **********************************************************
vmwNsxTIPAMFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the IPAM feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 38 }
vmwNsxTIPAMFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for IPAM feature notifications.
"
::= { vmwNsxTIPAMFeaturePrefix 0 }
vmwNsxTIPAMIPBlockUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath
}
STATUS current
DESCRIPTION
"IP block usage of vmwNsxTDataCenterIntentPath is very high.
IP block nearing its total capacity, creation of subnet using IP block might fail.
Action required:
Please review IP block usage. Use new IP block for resource creation or delete unused IP subnet from the IP block.
To check subnet being used for IP Block. From NSX UI, navigate to Networking | IP Address pools | IP Address pools tab.
Select IP pools where IP block being used, check Subnets and Allocated IPs column on UI. If no allocation has been used for the IP pool and it is not going to be used in future then delete subnet or IP pool.
Use following API to check if IP block being used by IP pool and also check if any IP allocation done:
To get configured subnets of an IP pool, invoke the NSX API
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-subnets
To get IP allocations, invoke the NSX API
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations
Please note: Deletion of IP pool/subnet should only be done if it does not have any allocated IPs and it is not going to be used in future.
"
::= { vmwNsxTIPAMFeature 1 }
vmwNsxTIPAMIPBlockUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath
}
STATUS current
DESCRIPTION
"IP block usage of vmwNsxTDataCenterIntentPath is below threshold level.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIPAMFeature 2 }
vmwNsxTIPAMIPPoolUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath
}
STATUS current
DESCRIPTION
"IP pool usage of vmwNsxTDataCenterIntentPath is very high.
IP pool nearing its total capacity. Creation of entity/service depends on IP being allocated from IP pool might fail.
Action required:
Please review IP pool usage.
Release unused ip allocations from IP pool or create new IP pool and use it.
From NSX UI navigate to Networking | IP Address pools | IP Address pools tab.
Select IP pools and check Allocated IPs column, this will show IPs allocated from the IP pool.
If user see any IPs are not being used then those IPs can be released.
To release unused IP allocations, invoke the NSX API
DELETE /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations/<ip-allocation>
"
::= { vmwNsxTIPAMFeature 3 }
vmwNsxTIPAMIPPoolUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterIntentPath
}
STATUS current
DESCRIPTION
"IP pool usage of vmwNsxTDataCenterIntentPath is normal now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTIPAMFeature 4 }
-- **********************************************************
-- Licenses feature event notifications
-- **********************************************************
vmwNsxTLicensesFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Licenses feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 5 }
vmwNsxTLicensesFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Licenses feature notifications.
"
::= { vmwNsxTLicensesFeaturePrefix 0 }
vmwNsxTLicensesLicenseExpired NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLicenseEditionType,
vmwNsxTDataCenterDisplayedLicenseKey
}
STATUS current
DESCRIPTION
"The vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has expired.
Action required:
Add a new, non-expired license using the NSX UI by navigating to
System | Licenses then click ADD and specify the key of the new
license. The expired license should be deleted by checking the
checkbox of the license, then click DELETE.
"
::= { vmwNsxTLicensesFeature 1 }
vmwNsxTLicensesLicenseExpiredClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLicenseEditionType,
vmwNsxTDataCenterDisplayedLicenseKey
}
STATUS current
DESCRIPTION
"The expired vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
longer about to expire.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLicensesFeature 2 }
vmwNsxTLicensesLicenseIsAboutToExpire NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLicenseEditionType,
vmwNsxTDataCenterDisplayedLicenseKey
}
STATUS current
DESCRIPTION
"The vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, is about to expire.
Action required:
The license is about to expire in several days. Please plan to add a
new, non-expiring license using the NSX UI by navigating to System |
Licenses then click ADD and specify the key of the new license. The
expired license should be deleted by checking the checkbox of the
license, then click DELETE.
"
::= { vmwNsxTLicensesFeature 3 }
vmwNsxTLicensesLicenseIsAboutToExpireClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLicenseEditionType,
vmwNsxTDataCenterDisplayedLicenseKey
}
STATUS current
DESCRIPTION
"The expiring vmwNsxTDataCenterLicenseEditionType license key ending with
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
longer about to expire.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLicensesFeature 4 }
-- **********************************************************
-- LoadBalancer feature event notifications
-- **********************************************************
vmwNsxTLoadBalancerFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the LoadBalancer feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 17 }
vmwNsxTLoadBalancerFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for LoadBalancer feature notifications.
"
::= { vmwNsxTLoadBalancerFeaturePrefix 0 }
vmwNsxTLoadBalancerDLBStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The distributed load balancer service vmwNsxTDataCenterEntityId is down.
This notification is sent once when the down state is first detected.
Action required:
On ESXi host node, invoke the NSX CLI command `get load-balancer
<lb-uuid> status`.
If 'Conflict LSP' is reported, please check whether this LSP is attached
to other load balancer service. Please check whether this conflict is
acceptable.
If 'Not Ready LSP' is reported, please check the status of this LSP by
invoking NSX CLI command `get logical-switch-port status`.
"
::= { vmwNsxTLoadBalancerFeature 17 }
vmwNsxTLoadBalancerDLBStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The distributed load balancer service vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 18 }
vmwNsxTLoadBalancerLBCPUVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of load balancer vmwNsxTDataCenterEntityId is vmwNsxTDataCenterSystemResourceUsage%
which is higher than the very high threshold of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
If the load balancer CPU utilization is higher than vmwNsxTDataCenterSystemUsageThreshold%,
the workload is too high for this load balancer. Rescale the load balancer
service by changing the load balancer size from small to medium or from
medium to large. If the CPU utilization of this load balancer is still high,
consider adjusting the Edge appliance form factor size or moving load
balancer services to other Edge nodes for the applicable workload.
"
::= { vmwNsxTLoadBalancerFeature 1 }
vmwNsxTLoadBalancerLBCPUVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU utilization of load balancer vmwNsxTDataCenterEntityId is vmwNsxTDataCenterSystemResourceUsage%
which is lower than the very high threshold of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 2 }
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
This notification is sent once when the high usage state is first detected.
Action required:
If multiple LB instances have been configurerd in this Edge node, deploy a
new Edge node and move some LB instances to that new Edge node. If only a
single LB instance (small/medium/etc) has been configured in an Edge node of
same size (small/medium/etc), deploy a new Edge of bigger size and move the
LB instance to that new Edge node.
"
::= { vmwNsxTLoadBalancerFeature 3 }
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is below
the threshold of vmwNsxTDataCenterSystemUsageThreshold% for a sufficient number
of samples over 2 minutes.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 4 }
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high.
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
This notification is sent once when the high usage state is first detected.
Action required:
Deploy a new Edge node and move the load balancer service from existing Edge
nodes to the newly deployed Edge node.
"
::= { vmwNsxTLoadBalancerFeature 5 }
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is below
the threshold of vmwNsxTDataCenterSystemUsageThreshold% for a sufficient number
of samples over 2 minutes.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 6 }
vmwNsxTLoadBalancerLBStatusDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer service vmwNsxTDataCenterEntityId is degraded.
This notification is sent once when the degraded state is first detected.
Action required:
For centralized load balancer:
On standby Edge node, check load balancer status by invoking the NSX CLI
command `get load-balancer <lb-uuid> status`. If the LB-State of load
balancer service is not_ready or there is no output, make the Edge node
enter maintenance mode, then exit maintenance mode.
For distributed load balancer:
1. Get detailed status by invoking NSX-T API GET
/policy/api/v1/infra/lb-services/<LBService>/detailed-status?source=realtime
2. From API output, find ESXi host reporting a non-zero instance_number
with status NOT_READY or CONFLICT.
3. On ESXi host node, invoke the NSX CLI command `get load-balancer
<lb-uuid> status`.
If 'Conflict LSP'is reported, please check whether this LSP is attached
to other load balancer service. Please check whether this conflict is
acceptable.
If 'Not Ready LSP' is reported, please check the status of this LSP by
invoking NSX CLI command `get logical-switch-port status`.
"
::= { vmwNsxTLoadBalancerFeature 15 }
vmwNsxTLoadBalancerLBStatusDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer service vmwNsxTDataCenterEntityId is not degraded.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 16 }
vmwNsxTLoadBalancerLBStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer service vmwNsxTDataCenterEntityId is down.
Action required:
Verify whether the load balancer service in the Edge node is running.
If the status of load balancer service is not ready, make the Edge
node enter maintenance mode, then exit maintenance mode. If the status
of load balancer is still not recovered, please check whether there
are any error log in /var/log/syslog.
"
::= { vmwNsxTLoadBalancerFeature 7 }
vmwNsxTLoadBalancerLBStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The noad balancer service vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 8 }
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"The load balancer configuration vmwNsxTDataCenterEntityId is not realized,
due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId.
Action required:
Prefer defining small and medium sized load balancers over large sized load balancers.
Spread out load balancer services among the available Edge nodes.
Reduce number of Virtual Servers defined.
"
::= { vmwNsxTLoadBalancerFeature 19 }
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"The load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 20 }
vmwNsxTLoadBalancerPoolStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer pool vmwNsxTDataCenterEntityId status is down.
Action required:
Consult the load balancer pool to determine which members are down by
invoking the NSX CLI command
`get load-balancer <lb-uuid> pool <pool-uuid> status`
or NSX API GET
/policy/api/v1/infra/lb-services/<lb-service-id>/lb-pools/<lb-pool-id>/detailed-status
If DOWN or UNKNOWN is reported, please verify the pool member.
Check network connectivity from the load balancer to the impacted pool members.
Validate application health of each pool member. Also validate the health
of each pool member using the configured monitor. When the health of the
member is established, the pool member status is updated to healthy based
on the 'Rise Count' configuration in the monitor.
Remediate the issue by rebooting the pool member or make the Edge node
enter maintenance mode, then exit maintenance mode.
"
::= { vmwNsxTLoadBalancerFeature 9 }
vmwNsxTLoadBalancerPoolStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer pool vmwNsxTDataCenterEntityId status is up
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 10 }
vmwNsxTLoadBalancerVirtualServerStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer virtual server vmwNsxTDataCenterEntityId is down.
Action required:
Consult the load balancer pool to determine its status and verify its
configuration. If incorrectly configured, reconfigure it and remove the
load balancer pool from the virtual server then re-add it to the
virtual server again.
"
::= { vmwNsxTLoadBalancerFeature 11 }
vmwNsxTLoadBalancerVirtualServerStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The load balancer virtual server vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTLoadBalancerFeature 12 }
-- **********************************************************
-- ManagerHealth feature event notifications
-- **********************************************************
vmwNsxTManagerHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the ManagerHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 1 }
vmwNsxTManagerHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for ManagerHealth feature notifications.
"
::= { vmwNsxTManagerHealthFeaturePrefix 0 }
vmwNsxTManagerHealthDuplicateIPAddress NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDuplicateIPAddress
}
STATUS current
DESCRIPTION
"Manager node vmwNsxTDataCenterEntityId IP address vmwNsxTDataCenterDuplicateIPAddress is
currently being used by another device in the network.
Action required:
1. Determine which device is using the Manager's IP address
and assign the device a new IP address. Note, reconfiguring
the Manager to use a new IP address is not supported.
2. Ensure the static IP address pool/DHCP server is configured correctly.
3. Correct the IP address of the device if it is manually assigned.
"
::= { vmwNsxTManagerHealthFeature 17 }
vmwNsxTManagerHealthDuplicateIPAddressClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDuplicateIPAddress
}
STATUS current
DESCRIPTION
"The device using the IP address assigned to Manager node
vmwNsxTDataCenterEntityId appears to no longer be using vmwNsxTDataCenterDuplicateIPAddress.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 18 }
vmwNsxTManagerHealthManagerConfigDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /config has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
usage by the NSX Datastore service under the /config/corfu directory.
Action required:
Please run the following tool and contact GSS if any issues are reported
/opt/vmware/tools/support/inspect_checkpoint_issues.py
"
::= { vmwNsxTManagerHealthFeature 13 }
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /config has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 14 }
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /config has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
by the NSX Datastore service under the /config/corfu directory.
Action required:
Please run the following tool and contact GSS if any issues are reported
/opt/vmware/tools/support/inspect_checkpoint_issues.py
"
::= { vmwNsxTManagerHealthFeature 15 }
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /config has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 16 }
vmwNsxTManagerHealthManagerCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this
Manager node. Consider adjusting the Manager appliance form factor size.
"
::= { vmwNsxTManagerHealthFeature 1 }
vmwNsxTManagerHealthManagerCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 2 }
vmwNsxTManagerHealthManagerCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this
Manager node. Consider adjusting the Manager appliance form factor size.
"
::= { vmwNsxTManagerHealthFeature 3 }
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 4 }
vmwNsxTManagerHealthManagerDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine the partition with high usage and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTManagerHealthFeature 9 }
vmwNsxTManagerHealthManagerDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 10 }
vmwNsxTManagerHealthManagerDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Examine the partition with high usage and see if there are any
unexpected large files that can be removed.
"
::= { vmwNsxTManagerHealthFeature 11 }
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 12 }
vmwNsxTManagerHealthManagerMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this
Manager node. Consider adjusting the Manager appliance form factor size.
"
::= { vmwNsxTManagerHealthFeature 5 }
vmwNsxTManagerHealthManagerMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 6 }
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Please review the configuration, running services and sizing of this
Manager node. Consider adjusting the Manager appliance form factor size.
"
::= { vmwNsxTManagerHealthFeature 7 }
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 8 }
vmwNsxTManagerHealthOperationsDbDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /nonconfig has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
usage by the NSX Datastore service under the /nonconfig/corfu directory.
Action required:
Please run the following tool and contact GSS if any issues are reported
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
"
::= { vmwNsxTManagerHealthFeature 19 }
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /nonconfig has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 20 }
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /nonconfig has reached
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
by the NSX Datastore service under the /nonconfig/corfu directory.
Action required:
Please run the following tool and contact GSS if any issues are reported
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
"
::= { vmwNsxTManagerHealthFeature 21 }
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage for the Manager node disk partition /nonconfig has reached
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 22 }
vmwNsxTManagerHealthStorageError NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName
}
STATUS current
DESCRIPTION
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId is in
read-only mode: vmwNsxTDataCenterDiskPartitionName
Action required:
Examine the read-only partition to see if reboot resolves the issue
or the disk needs to be replaced. Contact GSS for more information.
"
::= { vmwNsxTManagerHealthFeature 23 }
vmwNsxTManagerHealthStorageErrorClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterDiskPartitionName
}
STATUS current
DESCRIPTION
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId
has recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTManagerHealthFeature 24 }
-- **********************************************************
-- MTUCheck feature event notifications
-- **********************************************************
vmwNsxTMTUCheckFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the MTUCheck feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 42 }
vmwNsxTMTUCheckFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for MTUCheck feature notifications.
"
::= { vmwNsxTMTUCheckFeaturePrefix 0 }
vmwNsxTMTUCheckGlobalRouterMTUTooBig NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The global router MTU configuration is bigger than MTU of switches in overlay Transport Zone which connects
to Tier0 or Tier1. Global router MTU value should be less than all switches MTU value by at least
a 100 as we require 100 quota for Geneve encapsulation.
Action required:
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
more mismatch details.
2. Set the bigger MTU value on switches by invoking the NSX API
PUT /api/v1/host-switch-profiles/<host-switch-profile-id> with mtu in the
request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
with physical_uplink_mtu in request body.
3. Or set the smaller MTU value of global router configuration by invoking the NSX API PUT
/api/v1/global-configs/RoutingGlobalConfig with logical_uplink_mtu in the request body.
"
::= { vmwNsxTMTUCheckFeature 3 }
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The global router MTU is less than the MTU of overlay Transport Zone now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTMTUCheckFeature 4 }
vmwNsxTMTUCheckMTUMismatchWithinTransportZone NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"MTU configuration mismatch between Transport Nodes (ESXi, KVM and Edge) attached to the same Transport Zone.
MTU values on all switches attached to the same Transport Zone not being consistent will cause
connectivity issues.
Action required:
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
more mismatch details.
2. Set the same MTU value on all switches attached to the same Transport Zone
by invoking the NSX API PUT /api/v1/host-switch-profiles/<host-switch-profile-id>
with mtu in the request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
with physical_uplink_mtu in request body.
"
::= { vmwNsxTMTUCheckFeature 1 }
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"All MTU values between Transport Nodes attached to the same Transport Zone are consistent now.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTMTUCheckFeature 2 }
-- **********************************************************
-- NAT feature event notifications
-- **********************************************************
vmwNsxTNATFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the NAT feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 46 }
vmwNsxTNATFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for NAT feature notifications.
"
::= { vmwNsxTNATFeaturePrefix 0 }
vmwNsxTNATSNATPortUsageOnGatewayIsHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSNATIPAddress,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for
SNAT IP vmwNsxTDataCenterSNATIPAddress has reached
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will
not be SNATed when usage reaches the maximum limit.
Action required:
Log in as the admin user on Edge node and invoke the NSX CLI command
`get firewall <LR_INT_UUID> connection state` by using the right interface
uuid and check various SNAT mappings for the SNAT IP vmwNsxTDataCenterSNATIPAddress.
Check traffic flows going through the gateway is not a denial-of-service
attack or anomalous burst. If the traffic appears to be within
the normal load but the alarm threshold is hit, consider adding more
SNAT IP addresses to distribute the load or
route new traffic to another Edge node.
"
::= { vmwNsxTNATFeature 1 }
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSNATIPAddress,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress
has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNATFeature 2 }
-- **********************************************************
-- NCPHealth feature event notifications
-- **********************************************************
vmwNsxTNCPHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the NCPHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 11 }
vmwNsxTNCPHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for NCPHealth feature notifications.
"
::= { vmwNsxTNCPHealthFeaturePrefix 0 }
vmwNsxTNCPHealthNCPPluginDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Manager Node has detected the NCP is down or unhealthy.
Action required:
To find the clusters which are having issues, please use the
NSX UI and navigate to the Alarms page. The Entity name value for
this alarm instance identifies the cluster name. Or invoke the
NSX API GET /api/v1/systemhealth/container-cluster/ncp/status
to fetch all cluster statuses and determine the name of any clusters
that report DOWN or UNKNOWN. Then on the NSX UI
Inventory | Container | Clusters page find the cluster by name and
click the Nodes tab which lists all Kubernetes and PAS cluster members.
For Kubernetes cluster:
1. Check NCP Pod liveness by finding the K8s master node from all the
cluster members and log onto the master node. Then invoke the kubectl
command `kubectl get pods --all-namespaces`. If there is an issue with
the NCP Pod, please use kubectl logs command to check the issue and fix
the error.
2. Check the connection between NCP and Kubernetes API server. The
NSX CLI can be used inside the NCP Pod to check this connection status
by invoking the following commands from the master VM.
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
`nsxcli`
`get ncp-k8s-api-server status`
If there is an issue with the connection, please check both the network
and NCP configurations.
3. Check the connection between NCP and NSX Manager. The NSX CLI can be
used inside the NCP Pod to check this connection status by invoking the
following command from the master VM.
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
`nsxcli`
`get ncp-nsx status`
If there is an issue with the connection, please check both the network
and NCP configurations.
For PAS cluster:
1. Check the network connections between virtual machines and fix any
network issues.
2. Check the status of both nodes and services and fix crashed nodes
or services. Invoke the command `bosh vms` and `bosh instances -p` to
check the status of nodes and services.
"
::= { vmwNsxTNCPHealthFeature 3 }
vmwNsxTNCPHealthNCPPluginDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Manager Node has detected the NCP is up or healthy again.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNCPHealthFeature 4 }
-- **********************************************************
-- NodeAgentsHealth feature event notifications
-- **********************************************************
vmwNsxTNodeAgentsHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the NodeAgentsHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 12 }
vmwNsxTNodeAgentsHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for NodeAgentsHealth feature notifications.
"
::= { vmwNsxTNodeAgentsHealthFeaturePrefix 0 }
vmwNsxTNodeAgentsHealthNodeAgentsDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The agents running inside the Node VM appear to be down.
Action required:
For ESX:
1. If Vmk50 is missing, refer to this Knowledge Base article
https://kb.vmware.com/s/article/67432.
2. If Hyperbus 4094 is missing, restarting nsx-cfgagent or restarting the
container host VM may help.
3. If container host VIF is blocked, check the connection to the Controller
to make sure all configurations are sent down.
4. If nsx-cfg-agent has stopped, restart nsx-cfgagent.
For KVM:
1. If Hyperbus namespace is missing, restarting the nsx-opsagent may help
recreate the namespace.
2. If Hyperbus interface is missing inside the hyperbus namespace,
restarting the nsx-opsagent may help.
3. If nsx-agent has stopped, restart nsx-agent.
For Both ESX and KVM:
1. If the node-agent package is missing, check whether node-agent package
has been successfully installed in the container host vm.
2. If the interface for node-agent in container host vm is down, check the
eth1 interface status inside the container host vm.
"
::= { vmwNsxTNodeAgentsHealthFeature 3 }
vmwNsxTNodeAgentsHealthNodeAgentsDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The agents inside the Node VM are running.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNodeAgentsHealthFeature 4 }
-- **********************************************************
-- NSXApplicationPlatformCommunication feature event notifications
-- **********************************************************
vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the NSXApplicationPlatformCommunication feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 41 }
vmwNsxTNSXApplicationPlatformCommunicationFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for NSXApplicationPlatformCommunication feature notifications.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix 0 }
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappMessagingLAGThreshold
}
STATUS current
DESCRIPTION
"The number of pending messages in the messaging topic Over Flow is above the
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
Action required:
Add nodes and then scale up the NSX Application Platform cluster. If bottleneck can be attributed to a specific service,
for example, the analytics service, then scale up the specific service when the new nodes are added.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 7 }
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappMessagingLAGThreshold
}
STATUS current
DESCRIPTION
"The number of pending messages in the messaging topic Over Flow is below the pending
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 8 }
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappMessagingLAGThreshold
}
STATUS current
DESCRIPTION
"The number of pending messages in the messaging topic Raw Flow is above the
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
Action required:
Add nodes and then scale up the NSX Application Platform cluster. If the bottleneck can be attributed to a specific service,
for example, the analytics service, then scale up the specific service when the new nodes are added.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 11 }
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappMessagingLAGThreshold
}
STATUS current
DESCRIPTION
"The number of pending messages in the messaging topic Raw Flow is below the pending
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 12 }
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is disconnected
from the NSX management cluster.
Action required:
Check whether the manager cluster certificate, manager node certificates,
kafka certificate and ingress certificate match on both NSX Manager and the
NSX Application Platform cluster. Check expiration dates of the above mentioned
certificates to make sure they are valid. Check the network connection between
NSX Manager and NSX Application Platform cluster and resolve any network connection failures.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 1 }
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is reconnected
to the NSX management cluster.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 2 }
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
the NSX Application Platform cluster's messaging broker. Data collection is affected.
Action required:
Restart the messaging service if it is not running in the NSX Application
Platform cluster. Resolve the network connection failure between the Transport node
flow exporter and the NSX Application Platform cluster.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 13 }
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
the NSX Application Platform cluster's messaging broker.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 14 }
-- **********************************************************
-- NSXApplicationPlatformHealth feature event notifications
-- **********************************************************
vmwNsxTNSXApplicationPlatformHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the NSXApplicationPlatformHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 43 }
vmwNsxTNSXApplicationPlatformHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for NSXApplicationPlatformHealth feature notifications.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeaturePrefix 0 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Analytics service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 1 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Analytics service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 2 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Analytics service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 3 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Analytics service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 4 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Analytics service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 5 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Analytics service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 6 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Analytics service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 7 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Analytics service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 8 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Analytics service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 9 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Analytics service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 10 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Analytics service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Analytics service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 11 }
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Analytics service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 12 }
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the System Load field of individual services to see
which service is under pressure. See if the load can be reduced. If more
computing power is required, click on the Scale Out button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 13 }
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 14 }
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the System Load field of individual services to see
which service is under pressure. See if the load can be reduced. If more
computing power is required, click on the Scale Out button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 15 }
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 16 }
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Storage field of individual services to see
which service is under pressure. See if the load can be reduced. If more
disk storage is required, click on the Scale Out button to request more resources.
If data storage service is under strain, another way is to click on the Scale Up button
to increase disk size.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 17 }
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 18 }
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Storage field of individual services to see
which service is under pressure. See if the load can be reduced. If more
disk storage is required, click on the Scale Out button to request more resources.
If data storage service is under strain, another way is to click on the Scale Up button
to increase disk size.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 19 }
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 20 }
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Memory field of individual services to see
which service is under pressure. See if the load can be reduced. If more
memory is required, click on the Scale Out button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 21 }
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 22 }
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Memory field of individual services to see
which service is under pressure. See if the load can be reduced. If more
memory is required, click on the Scale Out button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 23 }
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 24 }
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Configuration Database service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 31 }
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Configuration Database service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 32 }
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Configuration Database service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 33 }
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Configuration Database service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 34 }
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Configuration Database service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 35 }
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Configuration Database service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 36 }
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Configuration Database service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 37 }
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Configuration Database service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 38 }
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Configuration Database service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 109 }
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Configuration Database service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 110 }
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Configuration Database service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 39 }
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Configuration Database service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 40 }
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Data Storage service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Data Storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 41 }
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Data Storage service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 42 }
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Data Storage service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Data Storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 43 }
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Data Storage service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 44 }
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Data Storage service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out or scale up the data storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 45 }
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Data Storage service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 46 }
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Data Storage service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out or scale up the data storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 47 }
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Data Storage service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 48 }
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Data Storage service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Data Storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 49 }
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Data Storage service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 50 }
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Data Storage service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Data Storage service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 51 }
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Data Storage service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 52 }
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Messaging service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 53 }
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Messaging service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 54 }
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Messaging service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 55 }
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Messaging service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 56 }
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Messaging service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 57 }
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Messaging service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 58 }
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Messaging service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 59 }
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Messaging service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 60 }
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Messaging service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 61 }
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Messaging service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 62 }
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Messaging service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services or the Messaging service.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 63 }
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Messaging service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 64 }
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Metrics service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 97 }
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Metrics service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 98 }
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Metrics service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 99 }
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Metrics service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 100 }
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Metrics service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 101 }
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Metrics service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 102 }
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Metrics service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 103 }
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Metrics service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 104 }
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Metrics service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 105 }
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Metrics service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 106 }
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Metrics service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 107 }
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Metrics service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 108 }
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is degraded.
Action required:
Get more information from alarms of nodes and services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 117 }
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 118 }
vmwNsxTNSXApplicationPlatformHealthNappStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is down.
Action required:
Get more information from alarms of nodes and services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 119 }
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappClusterId
}
STATUS current
DESCRIPTION
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 120 }
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the System Load field of individual services to see
which service is under pressure. See if load can be reduced. If only a small minority
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 65 }
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 66 }
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the System Load field of individual services to see
which service is under pressure. See if load can be reduced. If only a small minority
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 67 }
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 68 }
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Storage field of individual services to see which service is
under pressure. Clean up unused data or log to free up disk resources
and see if the load can be reduced. If more disk storage is required, Scale Out the
service under pressure. If data storage service is under strain, another way is to
click on the Scale Up button to increase disk size.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 69 }
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 70 }
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Storage field of individual services to see
which service is under pressure. Clean up unused data or log to free up disk resources
and see if the load can be reduced. If more disk storage is required, Scale Out the
service under pressure. If data storage service is under strain, another way is to
click on the Scale Up button to increase disk size.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 71 }
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 72 }
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Memory field of individual services to see
which service is under pressure. See if load can be reduced. If only a small minority
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 73 }
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 74 }
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services
and check the Memory field of individual services to see
which service is under pressure. See if load can be reduced. If only a small minority
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
button to request more resources.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 75 }
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 76 }
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName
}
STATUS current
DESCRIPTION
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is degraded.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Resources to
check which node is degraded. Check network, memory and CPU usage of the node.
Reboot the node if it is a worker node.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 77 }
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName
}
STATUS current
DESCRIPTION
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 78 }
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName
}
STATUS current
DESCRIPTION
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is not running.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Resources to
check which node is down. Check network, memory and CPU usage of the node.
Reboot the node if it is a worker node.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 79 }
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappNodeName
}
STATUS current
DESCRIPTION
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 80 }
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Platform Services service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 81 }
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Platform Services service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 82 }
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Platform Services service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 83 }
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The CPU usage of Platform Services service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 84 }
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Platform Services service is above the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 85 }
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Platform Services service is below the high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 86 }
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Platform Services service is above the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Clean up files not needed.
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 87 }
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The disk usage of Platform Services service is below the very high
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 88 }
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Platform Services service is above the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 89 }
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Platform Services service is below the high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 90 }
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Platform Services service is above the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
Scale out all services.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 91 }
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSystemUsageThreshold
}
STATUS current
DESCRIPTION
"The memory usage of Platform Services service is below the very high threshold
value of vmwNsxTDataCenterSystemUsageThreshold%.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 92 }
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappServiceName
}
STATUS current
DESCRIPTION
"Service vmwNsxTDataCenterNappServiceName is degraded. The service may still be able to reach a quorum while
pods associated with vmwNsxTDataCenterNappServiceName are not all stable. Resources consumed by these
unstable pods may be released.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
specific service is degraded and the reason behind it. Invoke the following CLI command to restart
the degraded service if necessary:
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
Degraded services can function correctly but performance is sub-optimal.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 93 }
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappServiceName
}
STATUS current
DESCRIPTION
"Service vmwNsxTDataCenterNappServiceName is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 94 }
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappServiceName
}
STATUS current
DESCRIPTION
"Service vmwNsxTDataCenterNappServiceName is not running.
Action required:
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
specific service is down and the reason behind it. Invoke the following CLI command to restart
the degraded service:
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 95 }
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterNappServiceName
}
STATUS current
DESCRIPTION
"Service vmwNsxTDataCenterNappServiceName is running properly.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTNSXApplicationPlatformHealthFeature 96 }
-- **********************************************************
-- PasswordManagement feature event notifications
-- **********************************************************
vmwNsxTPasswordManagementFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the PasswordManagement feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 4 }
vmwNsxTPasswordManagementFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for PasswordManagement feature notifications.
"
::= { vmwNsxTPasswordManagementFeaturePrefix 0 }
vmwNsxTPasswordManagementPasswordExpirationApproaching NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername,
vmwNsxTDataCenterPasswordExpirationDays
}
STATUS current
DESCRIPTION
"The password for user vmwNsxTDataCenterUsername is approaching expiration in
vmwNsxTDataCenterPasswordExpirationDays days.
Action required:
The password for the user vmwNsxTDataCenterUsername needs to be changed soon. For example,
to apply a new password to a user, invoke the following NSX API with a valid
password in the request body: PUT /api/v1/node/users/<userid> where <userid>
is the ID of the user.
"
::= { vmwNsxTPasswordManagementFeature 1 }
vmwNsxTPasswordManagementPasswordExpirationApproachingClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername
}
STATUS current
DESCRIPTION
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
is no longer expired.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTPasswordManagementFeature 2 }
vmwNsxTPasswordManagementPasswordExpired NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername
}
STATUS current
DESCRIPTION
"The password for user vmwNsxTDataCenterUsername has expired.
Action required:
The password for user vmwNsxTDataCenterUsername must be changed now to access the
system. For example, to apply a new password to a user, invoke the
following NSX API with a valid password in the request body: PUT
/api/v1/node/users/<userid> where <userid> is the ID of the user. If the
admin user (with <userid> 10000) password has expired, admin must login to
the system via SSH (if enabled) or console in order to change the password.
Upon entering the current expired password, admin will be prompted to enter
a new password.
"
::= { vmwNsxTPasswordManagementFeature 3 }
vmwNsxTPasswordManagementPasswordExpiredClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername
}
STATUS current
DESCRIPTION
"The password for user vmwNsxTDataCenterUsername has been changed successfully or
is no longer expired.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTPasswordManagementFeature 4 }
vmwNsxTPasswordManagementPasswordIsAboutToExpire NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername,
vmwNsxTDataCenterPasswordExpirationDays
}
STATUS current
DESCRIPTION
"The password for user vmwNsxTDataCenterUsername is about to expire in
vmwNsxTDataCenterPasswordExpirationDays days.
Action required:
Ensure the password for the user vmwNsxTDataCenterUsername is changed immediately. For
example, to apply a new password to a user, invoke the following NSX API
with a valid password in the request body: PUT /api/v1/node/users/<userid>
where <userid> is the ID of the user.
"
::= { vmwNsxTPasswordManagementFeature 5 }
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterUsername
}
STATUS current
DESCRIPTION
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
is no longer expired.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTPasswordManagementFeature 6 }
-- **********************************************************
-- Routing feature event notifications
-- **********************************************************
vmwNsxTRoutingFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the Routing feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 28 }
vmwNsxTRoutingFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for Routing feature notifications.
"
::= { vmwNsxTRoutingFeaturePrefix 0 }
vmwNsxTRoutingBFDDownOnExternalInterface NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterPeerAddress,
vmwNsxTDataCenterSrId
}
STATUS current
DESCRIPTION
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is down.
Action required:
1. Invoke the NSX CLI command `get logical-routers`.
2. Switch to the service router vmwNsxTDataCenterSrId
3. Invoke the NSX CLI command `ping vmwNsxTDataCenterPeerAddress` to verify the
connectivity.
"
::= { vmwNsxTRoutingFeature 7 }
vmwNsxTRoutingBFDDownOnExternalInterfaceClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterPeerAddress
}
STATUS current
DESCRIPTION
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 8 }
vmwNsxTRoutingBGPDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterBGPNeighborIP,
vmwNsxTDataCenterFailureReason,
vmwNsxTDataCenterSrId
}
STATUS current
DESCRIPTION
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down.
Reason: vmwNsxTDataCenterFailureReason.
Action required:
1. Invoke the NSX CLI command `get logical-routers`.
2. Switch to service-router vmwNsxTDataCenterSrId.
If the reason indicates Network or config error -
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the
BGP neighbor status.
If the reason indicates `Edge is not ready`, check why edge is not in good state.
4. Invoke the NSX CLI command `get edge-cluster status` to check reason why edge might be down.
5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
6. Check any edge health related alarms to get more information.
Check /var/log/syslog to see if there are any errors related to BGP
connectivity.
"
::= { vmwNsxTRoutingFeature 1 }
vmwNsxTRoutingBGPDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterBGPNeighborIP
}
STATUS current
DESCRIPTION
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 2 }
vmwNsxTRoutingOSPFNeighborWentDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterPeerAddress
}
STATUS current
DESCRIPTION
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved from full to another state.
Action required:
1. Invoke the NSX CLI command `get logical-routers` to get the vrf id and
switch to TIER0 service router.
2. Run `get ospf neighbor` to check the current state of this neighbor. If the
neighbor is not listed in the output, the neighbor has gone down or out of
the network.
3. Invoke the NSX CLI command `ping <OSPF neighbor IP address>` to verify the
connectivity.
4. Also, verify the configuration for both NSX and peer router to ensure that
timers and area-id match.
5. Check /var/log/syslog to see if there are any errors related to connectivity.
"
::= { vmwNsxTRoutingFeature 11 }
vmwNsxTRoutingOSPFNeighborWentDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterPeerAddress
}
STATUS current
DESCRIPTION
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved to full state.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 12 }
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceIP,
vmwNsxTDataCenterLrportId,
vmwNsxTDataCenterLrId
}
STATUS current
DESCRIPTION
"Proxy arp for Service IP vmwNsxTDataCenterServiceIP and Service entity vmwNsxTDataCenterEntityId
is not configured as the number of arp proxy entries generated due to overlap of
the Service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId has exceeded
the allowed threshold limit of 16384.
This notification is sent once when the threshold limit is exceeded.
Action required:
Reconfigure the Service IP vmwNsxTDataCenterServiceIP for the Service entity vmwNsxTDataCenterEntityId
or change the subnet of the lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId so that the proxy arp entries
generated due to the overlap between the Service IP and the subnet of lrport is less than
the allowed threshold limit of 16384.
"
::= { vmwNsxTRoutingFeature 13 }
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrportId,
vmwNsxTDataCenterLrId
}
STATUS current
DESCRIPTION
"Proxy arp for Service entity vmwNsxTDataCenterEntityId is generated successfully as the
overlap of service Ip with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId is
within the allowed limit of 16384 entries.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 14 }
vmwNsxTRoutingRoutingDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"All BGP/BFD sessions are down.
Action required:
Invoke the NSX CLI command `get logical-routers` to get the tier0 service router
and switch to this vrf, then invoke the following NSX CLI commands.
1. `ping <BFD peer IP address>` to verify connectivity.
2. `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
3. `get bgp neighbor summary` to check if BGP is running well.
Also check /var/log/syslog to see if there are any errors related to BGP
connectivity.
"
::= { vmwNsxTRoutingFeature 9 }
vmwNsxTRoutingRoutingDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"At least one BGP/BFD session up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 10 }
vmwNsxTRoutingStaticRoutingRemoved NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterStaticAddress,
vmwNsxTDataCenterSrId
}
STATUS current
DESCRIPTION
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was removed because
BFD was down.
Action required:
The static routing entry was removed because the BFD session was down.
1. Invoke the NSX CLI command `get logical-routers`.
2. Switch to the service-router vmwNsxTDataCenterSrId.
3. Invoke the NSX CLI command `ping <BFD peer IP address>` to verify the
connectivity.
Also, verify the configuration in both NSX and the BFD peer to ensure that
timers have not been changed.
"
::= { vmwNsxTRoutingFeature 5 }
vmwNsxTRoutingStaticRoutingRemovedClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterStaticAddress
}
STATUS current
DESCRIPTION
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was re-added as BFD
recovered.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTRoutingFeature 6 }
-- **********************************************************
-- TransportNodeHealth feature event notifications
-- **********************************************************
vmwNsxTTransportNodeHealthFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the TransportNodeHealth feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 18 }
vmwNsxTTransportNodeHealthFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for TransportNodeHealth feature notifications.
"
::= { vmwNsxTTransportNodeHealthFeaturePrefix 0 }
vmwNsxTTransportNodeHealthLAGMemberDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"LACP reporting member down.
Action required:
Check the connection status of LAG members on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Find the bond(uplink) which is
reporting degraded or down.
4. Check the LACP member status details by logging into the failed host and
invoking `esxcli network vswitch dvs vmware lacp status get` on an ESXi
host or `ovs-appctl bond/show` and `ovs-appctl lacp/show` on a KVM host.
"
::= { vmwNsxTTransportNodeHealthFeature 5 }
vmwNsxTTransportNodeHealthLAGMemberDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"LACP reporting member up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTTransportNodeHealthFeature 6 }
vmwNsxTTransportNodeHealthNVDSUplinkDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.
"
::= { vmwNsxTTransportNodeHealthFeature 3 }
vmwNsxTTransportNodeHealthNVDSUplinkDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTTransportNodeHealthFeature 4 }
vmwNsxTTransportNodeHealthTransportNodeUplinkDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Uplink is going down.
Action required:
Check the physical NICs' status of uplinks on hosts.
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
Host Transport Nodes.
2. In the Host Transport Nodes list, check the Node Status column. Find the
Transport node with the degraded or down Node Status.
3. Select <transport node> | Monitor. Check the status details of the
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
ensure all uplink interfaces are connected and up regardless of whether they
are in use or not.
"
::= { vmwNsxTTransportNodeHealthFeature 7 }
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"Uplink is going up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTTransportNodeHealthFeature 8 }
-- **********************************************************
-- VPN feature event notifications
-- **********************************************************
vmwNsxTVPNFeaturePrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Notifications applicable to the VPN feature have this OID prefix."
::= { vmwNsxTDataCenterNotifications 15 }
vmwNsxTVPNFeature OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
for VPN feature notifications.
"
::= { vmwNsxTVPNFeaturePrefix 0 }
vmwNsxTVPNIPsecPolicyBasedSessionDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSessionDownReason
}
STATUS current
DESCRIPTION
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is down.
Reason: vmwNsxTDataCenterSessionDownReason.
Action required:
Check IPsec VPN session configuration and resolve errors based on the
session down reason.
"
::= { vmwNsxTVPNFeature 7 }
vmwNsxTVPNIPsecPolicyBasedSessionDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 8 }
vmwNsxTVPNIPsecPolicyBasedTunnelDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"One or more policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are down.
Action required:
Check IPsec VPN session configuration and resolve errors based on the
tunnel down reason.
"
::= { vmwNsxTVPNFeature 9 }
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"All policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 10 }
vmwNsxTVPNIPsecRouteBasedSessionDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterSessionDownReason
}
STATUS current
DESCRIPTION
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is down.
Reason: vmwNsxTDataCenterSessionDownReason.
Action required:
Check IPsec VPN session configuration and resolve errors based on the
session down reason.
"
::= { vmwNsxTVPNFeature 11 }
vmwNsxTVPNIPsecRouteBasedSessionDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 12 }
vmwNsxTVPNIPsecRouteBasedTunnelDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterTunnelDownReason
}
STATUS current
DESCRIPTION
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is down.
Reason: vmwNsxTDataCenterTunnelDownReason.
Action required:
Check IPsec VPN session configuration and resolve errors based on the
tunnel down reason.
"
::= { vmwNsxTVPNFeature 13 }
vmwNsxTVPNIPsecRouteBasedTunnelDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 14 }
vmwNsxTVPNIPsecServiceDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterServiceDownReason
}
STATUS current
DESCRIPTION
"The IPsec service vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterServiceDownReason.
Action required:
1. Disable and enable the IPsec service from NSX Manager UI.
2. If the issue still persists, check syslog for error logs and contact
VMware support.
"
::= { vmwNsxTVPNFeature 17 }
vmwNsxTVPNIPsecServiceDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The IPsec service vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 18 }
vmwNsxTVPNL2VpnSessionDown NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The L2VPN session vmwNsxTDataCenterEntityId is down.
Action required:
Check L2VPN session status for session down reason and resolve errors based
on the reason.
"
::= { vmwNsxTVPNFeature 15 }
vmwNsxTVPNL2VpnSessionDownClear NOTIFICATION-TYPE
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterEntityId
}
STATUS current
DESCRIPTION
"The L2VPN session vmwNsxTDataCenterEntityId is up.
Action required:
None, receipt of this notification indicates event cleared.
"
::= { vmwNsxTVPNFeature 16 }
-- **********************************************************
-- Conformance information
-- **********************************************************
vmwNsxTDataCenterConformance OBJECT IDENTIFIER ::= { vmwNSXsysMIB 2 }
vmwNsxTDataCenterCompliances OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 1 }
vmwNsxTDataCenterSMIBGroups OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 2 }
-- **********************************************************
-- Compliance statements
-- **********************************************************
vmwNsxTDataCenterBasicCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationGroup
}
::= { vmwNsxTDataCenterCompliances 1 }
vmwNsxTDataCenterNotificationInfoGroup OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterTimestamp,
vmwNsxTDataCenterFeatureName,
vmwNsxTDataCenterEventType,
vmwNsxTDataCenterEventSeverity,
vmwNsxTDataCenterNodeId,
vmwNsxTDataCenterNodeType,
vmwNsxTDataCenterApplianceAddress,
vmwNsxTDataCenterBGPNeighborIP,
vmwNsxTDataCenterCurrentGatewayState,
vmwNsxTDataCenterCurrentServiceState,
vmwNsxTDataCenterDHCPPoolUsage,
vmwNsxTDataCenterDHCPServerId,
vmwNsxTDataCenterDatapathResourceUsage,
vmwNsxTDataCenterDiskPartitionName,
vmwNsxTDataCenterDuplicateIPAddress,
vmwNsxTDataCenterEdgeNICName,
vmwNsxTDataCenterEdgeServiceName,
vmwNsxTDataCenterEntityId,
vmwNsxTDataCenterEventId,
vmwNsxTDataCenterFailureReason,
vmwNsxTDataCenterHeapType,
vmwNsxTDataCenterIntelligenceNodeId,
vmwNsxTDataCenterLicenseEditionType,
vmwNsxTDataCenterMempoolName,
vmwNsxTDataCenterPasswordExpirationDays,
vmwNsxTDataCenterPeerAddress,
vmwNsxTDataCenterPreviousGatewayState,
vmwNsxTDataCenterPreviousServiceState,
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
vmwNsxTDataCenterServiceName,
vmwNsxTDataCenterSessionDownReason,
vmwNsxTDataCenterSrId,
vmwNsxTDataCenterStaticAddress,
vmwNsxTDataCenterSystemResourceUsage,
vmwNsxTDataCenterSystemUsageThreshold,
vmwNsxTDataCenterTunnelDownReason,
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
vmwNsxTDataCenterUsername
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 1 }
vmwNsxTDataCenterNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTAlarmManagementAlarmServiceOverloaded,
vmwNsxTAlarmManagementAlarmServiceOverloadedClear,
vmwNsxTAlarmManagementHeavyVolumeOfAlarms,
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear,
vmwNsxTCertificatesCertificateExpirationApproaching,
vmwNsxTCertificatesCertificateExpirationApproachingClear,
vmwNsxTCertificatesCertificateExpired,
vmwNsxTCertificatesCertificateExpiredClear,
vmwNsxTCertificatesCertificateIsAboutToExpire,
vmwNsxTCertificatesCertificateIsAboutToExpireClear,
vmwNsxTCniHealthHyperbusManagerConnectionDown,
vmwNsxTCniHealthHyperbusManagerConnectionDownClear,
vmwNsxTDHCPPoolLeaseAllocationFailed,
vmwNsxTDHCPPoolLeaseAllocationFailedClear,
vmwNsxTDHCPPoolOverloaded,
vmwNsxTDHCPPoolOverloadedClear,
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh,
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear,
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh,
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear,
vmwNsxTDNSForwarderDisabled,
vmwNsxTDNSForwarderDisabledClear,
vmwNsxTDNSForwarderDown,
vmwNsxTDNSForwarderDownClear,
vmwNsxTEdgeHealthEdgeCPUUsageHigh,
vmwNsxTEdgeHealthEdgeCPUUsageHighClear,
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh,
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear,
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure,
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear,
vmwNsxTEdgeHealthEdgeDatapathCPUHigh,
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear,
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh,
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear,
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown,
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear,
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh,
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear,
vmwNsxTEdgeHealthEdgeDiskUsageHigh,
vmwNsxTEdgeHealthEdgeDiskUsageHighClear,
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh,
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear,
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh,
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear,
vmwNsxTEdgeHealthEdgeMemoryUsageHigh,
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear,
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh,
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear,
vmwNsxTEdgeHealthEdgeNICLinkStatusDown,
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear,
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer,
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear,
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer,
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear,
vmwNsxTEndpointProtectionEAMStatusDown,
vmwNsxTEndpointProtectionEAMStatusDownClear,
vmwNsxTEndpointProtectionPartnerChannelDown,
vmwNsxTEndpointProtectionPartnerChannelDownClear,
vmwNsxTHighAvailabilityTier0GatewayFailover,
vmwNsxTHighAvailabilityTier0GatewayFailoverClear,
vmwNsxTHighAvailabilityTier1GatewayFailover,
vmwNsxTHighAvailabilityTier1GatewayFailoverClear,
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown,
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear,
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged,
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear,
vmwNsxTInfrastructureServiceEdgeServiceStatusDown,
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear,
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected,
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear,
vmwNsxTIntelligenceHealthCPUUsageHigh,
vmwNsxTIntelligenceHealthCPUUsageHighClear,
vmwNsxTIntelligenceHealthCPUUsageVeryHigh,
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear,
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh,
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear,
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh,
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear,
vmwNsxTIntelligenceHealthDiskUsageHigh,
vmwNsxTIntelligenceHealthDiskUsageHighClear,
vmwNsxTIntelligenceHealthDiskUsageVeryHigh,
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear,
vmwNsxTIntelligenceHealthMemoryUsageHigh,
vmwNsxTIntelligenceHealthMemoryUsageHighClear,
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh,
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear,
vmwNsxTIntelligenceHealthNodeStatusDegraded,
vmwNsxTIntelligenceHealthNodeStatusDegradedClear,
vmwNsxTLicensesLicenseExpired,
vmwNsxTLicensesLicenseExpiredClear,
vmwNsxTLicensesLicenseIsAboutToExpire,
vmwNsxTLicensesLicenseIsAboutToExpireClear,
vmwNsxTLoadBalancerLBCPUVeryHigh,
vmwNsxTLoadBalancerLBCPUVeryHighClear,
vmwNsxTLoadBalancerLBStatusDown,
vmwNsxTLoadBalancerLBStatusDownClear,
vmwNsxTLoadBalancerPoolStatusDown,
vmwNsxTLoadBalancerPoolStatusDownClear,
vmwNsxTLoadBalancerVirtualServerStatusDown,
vmwNsxTLoadBalancerVirtualServerStatusDownClear,
vmwNsxTManagerHealthDuplicateIPAddress,
vmwNsxTManagerHealthDuplicateIPAddressClear,
vmwNsxTManagerHealthManagerConfigDiskUsageHigh,
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear,
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh,
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear,
vmwNsxTManagerHealthManagerCPUUsageHigh,
vmwNsxTManagerHealthManagerCPUUsageHighClear,
vmwNsxTManagerHealthManagerCPUUsageVeryHigh,
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear,
vmwNsxTManagerHealthManagerDiskUsageHigh,
vmwNsxTManagerHealthManagerDiskUsageHighClear,
vmwNsxTManagerHealthManagerDiskUsageVeryHigh,
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear,
vmwNsxTManagerHealthManagerMemoryUsageHigh,
vmwNsxTManagerHealthManagerMemoryUsageHighClear,
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh,
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear,
vmwNsxTNCPHealthNCPPluginDown,
vmwNsxTNCPHealthNCPPluginDownClear,
vmwNsxTNodeAgentsHealthNodeAgentsDown,
vmwNsxTNodeAgentsHealthNodeAgentsDownClear,
vmwNsxTPasswordManagementPasswordExpirationApproaching,
vmwNsxTPasswordManagementPasswordExpirationApproachingClear,
vmwNsxTPasswordManagementPasswordExpired,
vmwNsxTPasswordManagementPasswordExpiredClear,
vmwNsxTPasswordManagementPasswordIsAboutToExpire,
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear,
vmwNsxTRoutingBFDDownOnExternalInterface,
vmwNsxTRoutingBFDDownOnExternalInterfaceClear,
vmwNsxTRoutingBGPDown,
vmwNsxTRoutingBGPDownClear,
vmwNsxTRoutingRoutingDown,
vmwNsxTRoutingRoutingDownClear,
vmwNsxTRoutingStaticRoutingRemoved,
vmwNsxTRoutingStaticRoutingRemovedClear,
vmwNsxTTransportNodeHealthLAGMemberDown,
vmwNsxTTransportNodeHealthLAGMemberDownClear,
vmwNsxTTransportNodeHealthNVDSUplinkDown,
vmwNsxTTransportNodeHealthNVDSUplinkDownClear,
vmwNsxTVPNIPsecPolicyBasedSessionDown,
vmwNsxTVPNIPsecPolicyBasedSessionDownClear,
vmwNsxTVPNIPsecPolicyBasedTunnelDown,
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear,
vmwNsxTVPNIPsecRouteBasedSessionDown,
vmwNsxTVPNIPsecRouteBasedSessionDownClear,
vmwNsxTVPNIPsecRouteBasedTunnelDown,
vmwNsxTVPNIPsecRouteBasedTunnelDownClear,
vmwNsxTVPNL2VpnSessionDown,
vmwNsxTVPNL2VpnSessionDownClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 2 }
vmwNsxTDataCenterBasicCompliance2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2
}
::= { vmwNsxTDataCenterCompliances 2 }
vmwNsxTDataCenterNotificationInfoGroup2 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterBGPSourceIP,
vmwNsxTDataCenterRemoteSiteId,
vmwNsxTDataCenterRemoteSiteName,
vmwNsxTDataCenterSiteId,
vmwNsxTDataCenterSiteName
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 3 }
vmwNsxTDataCenterNotificationGroup2 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTEdgeHealthStorageError,
vmwNsxTEdgeHealthStorageErrorClear,
vmwNsxTFederationLmToLmSynchronizationError,
vmwNsxTFederationLmToLmSynchronizationErrorClear,
vmwNsxTFederationLmToLmSynchronizationWarning,
vmwNsxTFederationLmToLmSynchronizationWarningClear,
vmwNsxTFederationRtepBGPDown,
vmwNsxTFederationRtepBGPDownClear,
vmwNsxTManagerHealthOperationsDbDiskUsageHigh,
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear,
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh,
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 4 }
vmwNsxTDataCenterBasicCompliance3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3
}
::= { vmwNsxTDataCenterCompliances 3 }
vmwNsxTDataCenterNotificationInfoGroup3 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterLrId,
vmwNsxTDataCenterManagerNodeName,
vmwNsxTDataCenterRxMisses,
vmwNsxTDataCenterRxProcessed,
vmwNsxTDataCenterTransportNodeAddress,
vmwNsxTDataCenterTransportNodeName,
vmwNsxTDataCenterTxMisses,
vmwNsxTDataCenterTxProcessed
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 5 }
vmwNsxTDataCenterNotificationGroup3 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTCommunicationManagementChannelToTransportNodeDown,
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear,
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg,
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear,
vmwNsxTCommunicationManagerControlChannelDown,
vmwNsxTCommunicationManagerControlChannelDownClear,
vmwNsxTFederationRtepConnectivityLost,
vmwNsxTFederationRtepConnectivityLostClear,
vmwNsxTManagerHealthStorageError,
vmwNsxTManagerHealthStorageErrorClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 6 }
vmwNsxTDataCenterBasicCompliance4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4
}
::= { vmwNsxTDataCenterCompliances 4 }
vmwNsxTDataCenterNotificationInfoGroup4 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterActiveGlobalManager,
vmwNsxTDataCenterActiveGlobalManagers,
vmwNsxTDataCenterApplianceFQDN,
vmwNsxTDataCenterCapacityDisplayName,
vmwNsxTDataCenterCapacityUsageCount,
vmwNsxTDataCenterCentralControlPlaneId,
vmwNsxTDataCenterDirectoryDomain,
vmwNsxTDataCenterDisplayedLicenseKey,
vmwNsxTDataCenterEdgeThreadName,
vmwNsxTDataCenterHostnameOrIPAddressWithPort,
vmwNsxTDataCenterIDSEventsCount,
vmwNsxTDataCenterLDAPServer,
vmwNsxTDataCenterLatencySource,
vmwNsxTDataCenterLatencyThreshold,
vmwNsxTDataCenterLatencyValue,
vmwNsxTDataCenterManagerNodeId,
vmwNsxTDataCenterMaxCapacityThreshold,
vmwNsxTDataCenterMaxIDSEventsAllowed,
vmwNsxTDataCenterMaxSupportedCapacityCount,
vmwNsxTDataCenterMinCapacityThreshold,
vmwNsxTDataCenterRemoteApplianceAddress,
vmwNsxTDataCenterRemoteManagerNodeId,
vmwNsxTDataCenterTimeoutInMinutes
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 7 }
vmwNsxTDataCenterNotificationGroup4 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTAuditLogHealthAuditLogFileUpdateError,
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear,
vmwNsxTAuditLogHealthRemoteLoggingServerError,
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear,
vmwNsxTCapacityMaximumCapacity,
vmwNsxTCapacityMaximumCapacityClear,
vmwNsxTCapacityMaximumCapacityThreshold,
vmwNsxTCapacityMaximumCapacityThresholdClear,
vmwNsxTCapacityMinimumCapacityThreshold,
vmwNsxTCapacityMinimumCapacityThresholdClear,
vmwNsxTCommunicationControlChannelToManagerNodeDown,
vmwNsxTCommunicationControlChannelToManagerNodeDownClear,
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong,
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear,
vmwNsxTCommunicationControlChannelToTransportNodeDown,
vmwNsxTCommunicationControlChannelToTransportNodeDownClear,
vmwNsxTCommunicationControlChannelToTransportNodeDownLong,
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear,
vmwNsxTCommunicationManagerClusterLatencyHigh,
vmwNsxTCommunicationManagerClusterLatencyHighClear,
vmwNsxTCommunicationManagerFQDNLookupFailure,
vmwNsxTCommunicationManagerFQDNLookupFailureClear,
vmwNsxTCommunicationManagerFQDNReverseLookupFailure,
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear,
vmwNsxTDistributedIDSIPSMaxEventsReached,
vmwNsxTDistributedIDSIPSMaxEventsReachedClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown,
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh,
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear,
vmwNsxTEdgeHealthDatapathThreadDeadlocked,
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear,
vmwNsxTFederationGMToGMSplitBrain,
vmwNsxTFederationGMToGMSplitBrainClear,
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost,
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear,
vmwNsxTIdentityFirewallErrorInDeltaSync,
vmwNsxTIdentityFirewallErrorInDeltaSyncClear,
vmwNsxTInfrastructureServiceServiceStatusUnknown,
vmwNsxTInfrastructureServiceServiceStatusUnknownClear,
vmwNsxTIntelligenceHealthStorageLatencyHigh,
vmwNsxTIntelligenceHealthStorageLatencyHighClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 8 }
vmwNsxTDataCenterBasicCompliance5 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4,
vmwNsxTDataCenterNotificationGroup5
}
::= { vmwNsxTDataCenterCompliances 5 }
vmwNsxTDataCenterNotificationGroup5 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTRoutingOSPFNeighborWentDown,
vmwNsxTRoutingOSPFNeighborWentDownClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 10 }
vmwNsxTDataCenterBasicCompliance6 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationInfoGroup6,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4,
vmwNsxTDataCenterNotificationGroup5,
vmwNsxTDataCenterNotificationGroup6
}
::= { vmwNsxTDataCenterCompliances 6 }
vmwNsxTDataCenterNotificationInfoGroup6 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterLrportId,
vmwNsxTDataCenterServiceIP
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 11 }
vmwNsxTDataCenterNotificationGroup6 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP,
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 12 }
vmwNsxTDataCenterBasicCompliance7 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationInfoGroup6,
vmwNsxTDataCenterNotificationInfoGroup7,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4,
vmwNsxTDataCenterNotificationGroup5,
vmwNsxTDataCenterNotificationGroup6,
vmwNsxTDataCenterNotificationGroup7
}
::= { vmwNsxTDataCenterCompliances 7 }
vmwNsxTDataCenterNotificationInfoGroup7 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterIntentPath
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 13 }
vmwNsxTDataCenterNotificationGroup7 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTIPAMIPBlockUsageVeryHigh,
vmwNsxTIPAMIPBlockUsageVeryHighClear,
vmwNsxTIPAMIPPoolUsageVeryHigh,
vmwNsxTIPAMIPPoolUsageVeryHighClear,
vmwNsxTLoadBalancerDLBStatusDown,
vmwNsxTLoadBalancerDLBStatusDownClear,
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh,
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear,
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh,
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear,
vmwNsxTLoadBalancerLBStatusDegraded,
vmwNsxTLoadBalancerLBStatusDegradedClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 14 }
vmwNsxTDataCenterBasicCompliance8 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationInfoGroup7,
vmwNsxTDataCenterNotificationInfoGroup8,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4,
vmwNsxTDataCenterNotificationGroup5,
vmwNsxTDataCenterNotificationGroup6,
vmwNsxTDataCenterNotificationGroup7,
vmwNsxTDataCenterNotificationGroup8
}
::= { vmwNsxTDataCenterCompliances 8 }
vmwNsxTDataCenterNotificationInfoGroup8 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterDNSId,
vmwNsxTDataCenterDNSUpstreamIP,
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
vmwNsxTDataCenterFirewallICMPFlowUsage,
vmwNsxTDataCenterFirewallIPFlowUsage,
vmwNsxTDataCenterFirewallUDPFlowUsage
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 15 }
vmwNsxTDataCenterNotificationGroup8 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTDNSForwarderUpstreamServerTimeout,
vmwNsxTDNSForwarderUpstreamServerTimeoutClear,
vmwNsxTGatewayFirewallICMPFlowCountExceeded,
vmwNsxTGatewayFirewallICMPFlowCountExceededClear,
vmwNsxTGatewayFirewallICMPFlowCountHigh,
vmwNsxTGatewayFirewallICMPFlowCountHighClear,
vmwNsxTGatewayFirewallIPFlowCountExceeded,
vmwNsxTGatewayFirewallIPFlowCountExceededClear,
vmwNsxTGatewayFirewallIPFlowCountHigh,
vmwNsxTGatewayFirewallIPFlowCountHighClear,
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded,
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear,
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh,
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear,
vmwNsxTGatewayFirewallUDPFlowCountExceeded,
vmwNsxTGatewayFirewallUDPFlowCountExceededClear,
vmwNsxTGatewayFirewallUDPFlowCountHigh,
vmwNsxTGatewayFirewallUDPFlowCountHighClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 16 }
vmwNsxTDataCenterBasicCompliance9 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement VMWARE-NSX-MIB."
MODULE -- this module
MANDATORY-GROUPS {
vmwNsxTDataCenterNotificationInfoGroup,
vmwNsxTDataCenterNotificationInfoGroup2,
vmwNsxTDataCenterNotificationInfoGroup3,
vmwNsxTDataCenterNotificationInfoGroup4,
vmwNsxTDataCenterNotificationInfoGroup7,
vmwNsxTDataCenterNotificationInfoGroup8,
vmwNsxTDataCenterNotificationInfoGroup9,
vmwNsxTDataCenterNotificationGroup,
vmwNsxTDataCenterNotificationGroup2,
vmwNsxTDataCenterNotificationGroup3,
vmwNsxTDataCenterNotificationGroup4,
vmwNsxTDataCenterNotificationGroup5,
vmwNsxTDataCenterNotificationGroup6,
vmwNsxTDataCenterNotificationGroup7,
vmwNsxTDataCenterNotificationGroup8,
vmwNsxTDataCenterNotificationGroup9
}
::= { vmwNsxTDataCenterCompliances 9 }
vmwNsxTDataCenterNotificationInfoGroup9 OBJECT-GROUP
OBJECTS {
vmwNsxTDataCenterAPICollectionPath,
vmwNsxTDataCenterCABundleAgeThreshold,
vmwNsxTDataCenterEdgeCryptoDrvName,
vmwNsxTDataCenterEdgeNodeSettingMismatchReason,
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason,
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason,
vmwNsxTDataCenterEdgevSphereLocationMismatchReason,
vmwNsxTDataCenterFirewallSNATPortsUsage,
vmwNsxTDataCenterFlowIdentifier,
vmwNsxTDataCenterFromGMPath,
vmwNsxTDataCenterGroupType,
vmwNsxTDataCenterManagerNodeIDS,
vmwNsxTDataCenterNICThroughput,
vmwNsxTDataCenterNICThroughputThreshold,
vmwNsxTDataCenterNappClusterId,
vmwNsxTDataCenterNappMessagingLAGThreshold,
vmwNsxTDataCenterNappNodeId,
vmwNsxTDataCenterNappNodeName,
vmwNsxTDataCenterNappServiceName,
vmwNsxTDataCenterQueueName,
vmwNsxTDataCenterQueueSize,
vmwNsxTDataCenterQueueSizeThreshold,
vmwNsxTDataCenterSNATIPAddress,
vmwNsxTDataCenterServiceDownReason,
vmwNsxTDataCenterServiceRouterId,
vmwNsxTDataCenterSyncIssueReason,
vmwNsxTDataCenterToGMPath,
vmwNsxTDataCenterTransportNodeId
}
STATUS current
DESCRIPTION
"These objects provide details in NSX-T Data Center event notifications."
::= { vmwNsxTDataCenterSMIBGroups 17 }
vmwNsxTDataCenterNotificationGroup9 NOTIFICATION-GROUP
NOTIFICATIONS {
vmwNsxTCertificatesCABundleUpdateRecommended,
vmwNsxTCertificatesCABundleUpdateRecommendedClear,
vmwNsxTCertificatesCABundleUpdateSuggested,
vmwNsxTCertificatesCABundleUpdateSuggestedClear,
vmwNsxTClusteringClusterDegraded,
vmwNsxTClusteringClusterDegradedClear,
vmwNsxTClusteringClusterUnavailable,
vmwNsxTClusteringClusterUnavailableClear,
vmwNsxTCommunicationManagementChannelToManagerNodeDown,
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear,
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong,
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear,
vmwNsxTDistributedFirewallDFWSessionCountHigh,
vmwNsxTDistributedFirewallDFWSessionCountHighClear,
vmwNsxTDistributedFirewallDFWVmotionFailure,
vmwNsxTDistributedFirewallDFWVmotionFailureClear,
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged,
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear,
vmwNsxTEdgeEdgeNodeSettingsMismatch,
vmwNsxTEdgeEdgeNodeSettingsMismatchClear,
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch,
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear,
vmwNsxTEdgeEdgevSphereLocationMismatch,
vmwNsxTEdgeEdgevSphereLocationMismatchClear,
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh,
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear,
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh,
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear,
vmwNsxTEdgeHealthFailureDomainDown,
vmwNsxTEdgeHealthFailureDomainDownClear,
vmwNsxTFederationGMToGMLatencyWarning,
vmwNsxTFederationGMToGMLatencyWarningClear,
vmwNsxTFederationGMToGMSynchronizationError,
vmwNsxTFederationGMToGMSynchronizationErrorClear,
vmwNsxTFederationGMToGMSynchronizationWarning,
vmwNsxTFederationGMToGMSynchronizationWarningClear,
vmwNsxTFederationGMToLMLatencyWarning,
vmwNsxTFederationGMToLMLatencyWarningClear,
vmwNsxTFederationGMToLMSynchronizationError,
vmwNsxTFederationGMToLMSynchronizationErrorClear,
vmwNsxTFederationGMToLMSynchronizationWarning,
vmwNsxTFederationGMToLMSynchronizationWarningClear,
vmwNsxTFederationLMRestoreWhileConfigImportInProgress,
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear,
vmwNsxTFederationQueueOccupancyThresholdExceeded,
vmwNsxTFederationQueueOccupancyThresholdExceededClear,
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory,
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear,
vmwNsxTMTUCheckGlobalRouterMTUTooBig,
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear,
vmwNsxTMTUCheckMTUMismatchWithinTransportZone,
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear,
vmwNsxTNATSNATPortUsageOnGatewayIsHigh,
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear,
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow,
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear,
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow,
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear,
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected,
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear,
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected,
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi,
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh,
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi,
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear,
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi,
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear,
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded,
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear,
vmwNsxTNSXApplicationPlatformHealthNappStatusDown,
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear,
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded,
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear,
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown,
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear,
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh,
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh,
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear,
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh,
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh,
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear,
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi,
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear,
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded,
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear,
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown,
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear,
vmwNsxTTransportNodeHealthTransportNodeUplinkDown,
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear,
vmwNsxTVPNIPsecServiceDown,
vmwNsxTVPNIPsecServiceDownClear
}
STATUS current
DESCRIPTION
"Group of objects describing event notifications emitted by
NSX-T Data Center.
"
::= { vmwNsxTDataCenterSMIBGroups 18 }
END