13580 lines
510 KiB
Plaintext
13580 lines
510 KiB
Plaintext
-- **********************************************************
|
|
-- Copyright 2019-2022 VMware, Inc. All rights reserved.
|
|
-- **********************************************************
|
|
|
|
VMWARE-NSX-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC
|
|
vmwNSXsys
|
|
FROM VMWARE-ROOT-MIB;
|
|
|
|
vmwNSXsysMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202202140000Z"
|
|
ORGANIZATION "VMware, Inc"
|
|
CONTACT-INFO
|
|
"VMware, Inc
|
|
3401 Hillview Ave
|
|
Palo Alto, CA 94304
|
|
Tel: 1-877-486-9273 or 650-427-5000
|
|
Fax: 650-427-5001
|
|
Web: http://kb.vmware.com/kb/1013445
|
|
"
|
|
|
|
DESCRIPTION
|
|
"In much the same way that server virtualization programmatically
|
|
creates, snapshots, deletes, and restores software-based virtual
|
|
machines (VMs), NSX-T Data Center network virtualization
|
|
programmatically creates, deletes, and restores software-based
|
|
virtual networks.
|
|
|
|
With network virtualization, the functional equivalent of a network
|
|
hypervisor reproduces the complete set of Layer 2 through Layer 7
|
|
networking services (for example, switching, routing, access control,
|
|
firewalling, QoS) in software. As a result, these services can be
|
|
programmatically assembled in any arbitrary combination, to produce
|
|
unique, isolated virtual networks in a matter of seconds.
|
|
|
|
For more information about NSX-T Data Center, please visit:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/
|
|
"
|
|
|
|
REVISION "202202140000Z"
|
|
DESCRIPTION
|
|
"This revision adds 174 new notifications for NSX-T Data Center 3.2.0"
|
|
|
|
REVISION "202108060000Z"
|
|
DESCRIPTION
|
|
"This revision adds 18 new notifications for NSX-T Data Center 3.1.3"
|
|
|
|
REVISION "202104220000Z"
|
|
DESCRIPTION
|
|
"This revision adds 12 new notifications for NSX-T Data Center 3.1.2"
|
|
|
|
REVISION "202103250000Z"
|
|
DESCRIPTION
|
|
"This revision adds 2 new notifications for NSX-T Data Center 3.0.3"
|
|
|
|
REVISION "202101300000Z"
|
|
DESCRIPTION
|
|
"This revision adds 2 new notifications for NSX-T Data Center 3.1.1"
|
|
|
|
REVISION "202010300000Z"
|
|
DESCRIPTION
|
|
"This revision adds 56 new notifications for NSX-T Data Center 3.1.0"
|
|
|
|
REVISION "202009220000Z"
|
|
DESCRIPTION
|
|
"This revision adds 10 new notifications for NSX-T Data Center 3.0.2"
|
|
|
|
REVISION "202006290000Z"
|
|
DESCRIPTION
|
|
"This revision adds 12 new notifications for NSX-T Data Center 3.0.1"
|
|
|
|
REVISION "202003240000Z"
|
|
DESCRIPTION
|
|
"Initial revision of NSX-T Data Center SNMP event notifications."
|
|
|
|
::= { vmwNSXsys 1 }
|
|
|
|
-- **********************************************************
|
|
-- Top-level MIB groups
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterNotifications OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All event notifications from NSX-T Data Center fall under this oid."
|
|
::= { vmwNSXsysMIB 0 }
|
|
|
|
vmwNsxTDataCenterData OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All variables that are sent in NSX-T Data Center event notifications
|
|
fall under this oid."
|
|
::= { vmwNSXsysMIB 1 }
|
|
|
|
-- **********************************************************
|
|
-- Type definitions
|
|
-- **********************************************************
|
|
|
|
VmwNsxTDataCenterFeatureIdType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX-T Data Center feature ID associated with the event.
|
|
For example, this value identifies the feature is managerHealth,
|
|
edgeHealth, loadBalancer, etc."
|
|
SYNTAX INTEGER {
|
|
managerHealth(1),
|
|
edgeHealth(2),
|
|
certificates(3),
|
|
passwordManagement(4),
|
|
licenses(5),
|
|
intelligenceHealth(6),
|
|
infrastructureCommunication(7),
|
|
intelligenceCommunication(9),
|
|
cniHealth(10),
|
|
ncpHealth(11),
|
|
nodeAgentsHealth(12),
|
|
endpointProtection(13),
|
|
vpn(15),
|
|
alarmManagement(16),
|
|
loadBalancer(17),
|
|
transportNodeHealth(18),
|
|
infrastructureService(19),
|
|
dhcp(20),
|
|
highAvailability(21),
|
|
capacity(22),
|
|
auditLogHealth(24),
|
|
routing(28),
|
|
dns(30),
|
|
distributedFirewall(31),
|
|
federation(32),
|
|
distributedIdsIps(33),
|
|
communication(35),
|
|
identityFirewall(36),
|
|
ipam(38),
|
|
gatewayFirewall(39),
|
|
clustering(40),
|
|
nsxApplicationPlatformCommunication(41),
|
|
mtuCheck(42),
|
|
nsxApplicationPlatformHealth(43),
|
|
edge(45),
|
|
nat(46)
|
|
}
|
|
|
|
VmwNsxTDataCenterEventTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NSX-T Data Center event. The complete set of events
|
|
are reported by the NSX API GET /api/v1/events."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSeverityType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the NSX-T Data Center event. Currently only the
|
|
critical(2), error(3), warning(4) and informational(6) levels
|
|
are used, but the other levels may be used in future releases."
|
|
SYNTAX INTEGER {
|
|
emergency(0),
|
|
alert(1),
|
|
critical(2),
|
|
error(3),
|
|
warning(4),
|
|
notice(5),
|
|
informational(6),
|
|
debug(7)
|
|
}
|
|
|
|
VmwNsxTDataCenterNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID from where a NSX-T Data Center event was emitted. A
|
|
node ID can be for a cluster node as reported by the NSX API
|
|
GET /api/v1/cluster. Or a node ID can be for a transport node
|
|
as reported by the NSX API GET /api/v1/transport-nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNodeTypeType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of node from where a NSX-T Data Center event was emitted."
|
|
SYNTAX INTEGER {
|
|
manager(0),
|
|
edge(1),
|
|
esx(2),
|
|
kvm(3),
|
|
publiccloudgateway(4),
|
|
intelligence(5),
|
|
autonomousedge(6),
|
|
globalmanager(7)
|
|
}
|
|
|
|
VmwNsxTDataCenterEntityIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a NSX-T Data Center entity an event pertains to. The event
|
|
description field provides additional details of the entity. For
|
|
example the ID can be for a specific Load Balancer rule as reported by
|
|
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
|
|
as reported by the NSX API GET /api/v1/trust-management/certificates."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSystemResourceUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of an NSX-T appliance. The
|
|
value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDiskPartitionNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a disk partition in an NSX-T appliance. For example, the
|
|
name for the /tmp partition is '/tmp'."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLicenseEditionTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The edition type of an NSX-T license. For example, the type for an NSX-T
|
|
evaluation license is 'NSX Data Center Evaluation'."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterApplianceAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's IP address. The value is an IPv4 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCurrentGatewayStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current gateway state. The value could be active/standby/admin down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCurrentServiceStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current service state. The value could be start/stop/restart/crashed."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDatapathResourceUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of the datapath on a NSX-T appliance.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDHCPPoolUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of a DHCP pool. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running on the Edge node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFailureReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detailed reason of any module failure like BGP down, IKE down, etc."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPreviousGatewayStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous gateway state. The value could be active/standby/admin down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPreviousServiceStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous service state. The value could be start/stop/restart/crashed."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSystemUsageThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the CPU, memory, or disk usage
|
|
percentage of an NSX-T appliance. The value is an integer between 0 and
|
|
100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterUsernameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a user in an NSX-T appliance."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDHCPServerIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a DHCP server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running in an NSX-T appliance."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIntelligenceNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX-T Intelligence node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHostnameOrIPAddressWithPortType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hostname or ip address with port of logging server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEventIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event identifier."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterActiveGlobalManagerType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for the active Global Manager node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterActiveGlobalManagersType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A comma delimited list of identifiers for the active Global Manager nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSessionDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN session."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX-T Manager node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of a NSX-T Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX-T Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCentralControlPlaneIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a NSX centrol control plane."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTunnelDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN tunnel."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHeapTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMempoolNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a memory pool."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPasswordExpirationDaysType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of days left before expiration of the password of an NSX-T
|
|
appliance user. The value is an integer greater than 0."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterBGPNeighborIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLDAPServerType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name or IP address of a LDAP server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPeerAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BFD peer."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxIDSEventsAllowedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of IDS events that are allowed in the system, anything beyond this
|
|
would be purged at regular intervals."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterStaticAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Static IP address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDuplicateIPAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplicate IP address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCapacityDisplayNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display name of type on capacity dashboard."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCapacityUsageCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current usage count of capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNICNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's receive descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
|
|
to accomodate new incoming packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's transmit descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
|
|
to accomodate new outgoing packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSrIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Router UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIDSEventsCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of the IDS events in the system currently."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteSiteNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a remote site in federation. For more information on remote
|
|
sites and an overview of the federation feature, please refer to:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterBGPSourceIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source IP address of BGP session. This could be either an IPv4 address
|
|
in dotted-decimal format or an IPv6 address in IPv6 address format."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteSiteIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for a remote site."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSiteIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for a local site."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSiteNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a local site in federation. For more information on local
|
|
sites and an overview of the federation feature, please refer to:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLrIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxMissesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets missed while receiving due to rx ring buffer being full."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxProcessedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of successful incoming packets while polling for rx buffer full event."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxMissesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets missed while transmitting due to tx ring buffer being full."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxProcessedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of successful outgoing packets while polling for tx buffer full event."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLrportIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router Port UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP configured for the service running in an NSX-T appliance in dotted-decimal format."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteManagerNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote Manager node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDirectoryDomainType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a directory domain."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTimeoutInMinutesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout value in minutes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxCapacityThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum threshold defined for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMinCapacityThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum threshold defined for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxSupportedCapacityCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum supported count for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencySourceType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of reported latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencyThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold value of reported IO latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencyValueType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of reported IO latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterApplianceFQDNType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's fully qualified domain name."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteApplianceAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote NSX appliance's IP address. The value is an IPv4 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Manager node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDisplayedLicenseKeyType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last 5 characters of the license key of an NSX-T license."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeThreadNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the Edge node thread."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIntentPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy intent path."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallHalfopenFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall TCP half-open connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallICMPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall ICMP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reason service is down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallUDPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall UDP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallIPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall IP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDNSIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DNS forwarder identifier."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDNSUpstreamIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of one DNS forwarder upstream server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCABundleAgeThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The age threshold in days for the CA bundle."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterAPICollectionPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The API path of the collection containing entity_id."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node settings
|
|
that differs from corresponding Edge transport node settings on Edge NSX CLI."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node vSphere
|
|
deployment configuration that differs from corresponding Edge transport node
|
|
configuration on vSphere."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallSNATPortsUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall SNAT ports usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of vSphere deployment configuration that differs
|
|
from corresponding Edge transport node configuration on vSphere when vMotion happens
|
|
for Edge node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node settings and vSphere
|
|
deployment configuration that differs from corresponding Edge transport node
|
|
settings on Edge NSX CLI and Edge transport node configuration on vSphere."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSNATIPAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNAT IP address which ran out of port threshold."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappClusterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cluster ID of the NSX Application Platform cluster."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappMessagingLAGThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the number of pending messages
|
|
in an NSX Application Platform messaging topic."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX Application Platform node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service name of an NSX Application Platform service."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFlowIdentifierType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A flow identifier indicating the direction of flow of data which is one of following.
|
|
- GM_2_LM
|
|
- LM_2_GM_NOTIFICATION
|
|
- LM_2_GM_ONBOARD_CONFIG"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSyncIssueReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reason for data synchronization issue."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the queue used to synchronize data between two sites."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueSizeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The occupancy size of queue used to synchronize data between two sites."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueSizeThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum threshold value of reported queue size."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterGroupTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group type of a GMLE cluster."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeIDSType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A comma delimited list of identifiers for the Manager nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceRouterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a service-router that is part of a tier0 or tier1 gateway
|
|
spanning one or more edges"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFromGMPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policy path of the Global Manager."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterToGMPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policy path of the Global Manager."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNICThroughputType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC throughput, as a percentage. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNICThroughputThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC throughput threshold, as a percentage. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeCryptoDrvNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the edge crypto driver."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node name of an NSX Application Platform node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
vmwNsxTDataCenterTimestamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp when the NSX-T Data Center event occurred."
|
|
::= { vmwNsxTDataCenterData 1 }
|
|
|
|
vmwNsxTDataCenterFeatureName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFeatureIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX-T Data Center feature ID associated with the event."
|
|
::= { vmwNsxTDataCenterData 2 }
|
|
|
|
vmwNsxTDataCenterEventType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEventTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NSX-T Data Center event."
|
|
::= { vmwNsxTDataCenterData 3 }
|
|
|
|
vmwNsxTDataCenterEventSeverity OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSeverityType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the NSX-T Data Center event."
|
|
::= { vmwNsxTDataCenterData 4 }
|
|
|
|
vmwNsxTDataCenterNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID from where a NSX-T Data Center event was emitted."
|
|
::= { vmwNsxTDataCenterData 5 }
|
|
|
|
vmwNsxTDataCenterNodeType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNodeTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of node from where a NSX-T Data Center event was emitted."
|
|
::= { vmwNsxTDataCenterData 6 }
|
|
|
|
vmwNsxTDataCenterEntityId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEntityIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a NSX-T Data Center entity an event pertains to. The event
|
|
description field provides additional details of the entity. For
|
|
example the ID can be for a specific Load Balancer rule as reported by
|
|
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
|
|
as reported by the NSX API GET /api/v1/trust-management/certificates."
|
|
::= { vmwNsxTDataCenterData 21 }
|
|
|
|
vmwNsxTDataCenterSystemResourceUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSystemResourceUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of an NSX-T appliance. The
|
|
value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 22 }
|
|
|
|
vmwNsxTDataCenterDiskPartitionName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDiskPartitionNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a disk partition in an NSX-T appliance. For example, the
|
|
name for the /tmp partition is '/tmp'."
|
|
::= { vmwNsxTDataCenterData 23 }
|
|
|
|
vmwNsxTDataCenterLicenseEditionType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLicenseEditionTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The edition type of an NSX-T license. For example, the type for an NSX-T
|
|
evaluation license is 'NSX Data Center Evaluation'."
|
|
::= { vmwNsxTDataCenterData 24 }
|
|
|
|
vmwNsxTDataCenterApplianceAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterApplianceAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's IP address. The value is an IPv4 address."
|
|
::= { vmwNsxTDataCenterData 25 }
|
|
|
|
vmwNsxTDataCenterCurrentGatewayState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCurrentGatewayStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current gateway state. The value could be active/standby/admin down."
|
|
::= { vmwNsxTDataCenterData 26 }
|
|
|
|
vmwNsxTDataCenterCurrentServiceState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCurrentServiceStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current service state. The value could be start/stop/restart/crashed."
|
|
::= { vmwNsxTDataCenterData 27 }
|
|
|
|
vmwNsxTDataCenterDatapathResourceUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDatapathResourceUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of the datapath on a NSX-T appliance.
|
|
The value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 28 }
|
|
|
|
vmwNsxTDataCenterDHCPPoolUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDHCPPoolUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of a DHCP pool. The value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 29 }
|
|
|
|
vmwNsxTDataCenterEdgeServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running on the Edge node."
|
|
::= { vmwNsxTDataCenterData 30 }
|
|
|
|
vmwNsxTDataCenterFailureReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFailureReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detailed reason of any module failure like BGP down, IKE down, etc."
|
|
::= { vmwNsxTDataCenterData 31 }
|
|
|
|
vmwNsxTDataCenterPreviousGatewayState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPreviousGatewayStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous gateway state. The value could be active/standby/admin down."
|
|
::= { vmwNsxTDataCenterData 32 }
|
|
|
|
vmwNsxTDataCenterPreviousServiceState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPreviousServiceStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous service state. The value could be start/stop/restart/crashed."
|
|
::= { vmwNsxTDataCenterData 33 }
|
|
|
|
vmwNsxTDataCenterSystemUsageThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSystemUsageThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the CPU, memory, or disk usage
|
|
percentage of an NSX-T appliance. The value is an integer between 0 and
|
|
100."
|
|
::= { vmwNsxTDataCenterData 34 }
|
|
|
|
vmwNsxTDataCenterUsername OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterUsernameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a user in an NSX-T appliance."
|
|
::= { vmwNsxTDataCenterData 35 }
|
|
|
|
vmwNsxTDataCenterDHCPServerId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDHCPServerIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a DHCP server."
|
|
::= { vmwNsxTDataCenterData 36 }
|
|
|
|
vmwNsxTDataCenterServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running in an NSX-T appliance."
|
|
::= { vmwNsxTDataCenterData 37 }
|
|
|
|
vmwNsxTDataCenterIntelligenceNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIntelligenceNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX-T Intelligence node."
|
|
::= { vmwNsxTDataCenterData 38 }
|
|
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHostnameOrIPAddressWithPortType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 39 }
|
|
|
|
vmwNsxTDataCenterEventId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEventIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event identifier."
|
|
::= { vmwNsxTDataCenterData 40 }
|
|
|
|
vmwNsxTDataCenterActiveGlobalManager OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterActiveGlobalManagerType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 41 }
|
|
|
|
vmwNsxTDataCenterActiveGlobalManagers OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterActiveGlobalManagersType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 42 }
|
|
|
|
vmwNsxTDataCenterSessionDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSessionDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN session."
|
|
::= { vmwNsxTDataCenterData 43 }
|
|
|
|
vmwNsxTDataCenterManagerNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 44 }
|
|
|
|
vmwNsxTDataCenterTransportNodeAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 45 }
|
|
|
|
vmwNsxTDataCenterTransportNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 46 }
|
|
|
|
vmwNsxTDataCenterCentralControlPlaneId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCentralControlPlaneIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 47 }
|
|
|
|
vmwNsxTDataCenterTunnelDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTunnelDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN tunnel."
|
|
::= { vmwNsxTDataCenterData 48 }
|
|
|
|
vmwNsxTDataCenterHeapType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHeapTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
|
|
::= { vmwNsxTDataCenterData 49 }
|
|
|
|
vmwNsxTDataCenterMempoolName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMempoolNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a memory pool."
|
|
::= { vmwNsxTDataCenterData 50 }
|
|
|
|
vmwNsxTDataCenterPasswordExpirationDays OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPasswordExpirationDaysType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of days left before expiration of the password of an NSX-T
|
|
appliance user. The value is an integer greater than 0."
|
|
::= { vmwNsxTDataCenterData 51 }
|
|
|
|
vmwNsxTDataCenterBGPNeighborIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterBGPNeighborIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
|
|
::= { vmwNsxTDataCenterData 52 }
|
|
|
|
vmwNsxTDataCenterLDAPServer OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLDAPServerType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 53 }
|
|
|
|
vmwNsxTDataCenterPeerAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPeerAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BFD peer."
|
|
::= { vmwNsxTDataCenterData 54 }
|
|
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxIDSEventsAllowedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 55 }
|
|
|
|
vmwNsxTDataCenterStaticAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterStaticAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Static IP address."
|
|
::= { vmwNsxTDataCenterData 56 }
|
|
|
|
vmwNsxTDataCenterDuplicateIPAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDuplicateIPAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplicate IP address."
|
|
::= { vmwNsxTDataCenterData 57 }
|
|
|
|
vmwNsxTDataCenterCapacityDisplayName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCapacityDisplayNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 58 }
|
|
|
|
vmwNsxTDataCenterCapacityUsageCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCapacityUsageCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 59 }
|
|
|
|
vmwNsxTDataCenterEdgeNICName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNICNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
|
|
::= { vmwNsxTDataCenterData 60 }
|
|
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxRingBufferOverflowPercentageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's receive descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
|
|
to accomodate new incoming packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
::= { vmwNsxTDataCenterData 61 }
|
|
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxRingBufferOverflowPercentageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's transmit descriptor ring buffer on a NSX-T Edge or Gateway node has no space left
|
|
to accomodate new outgoing packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
::= { vmwNsxTDataCenterData 62 }
|
|
|
|
vmwNsxTDataCenterSrId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSrIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Router UUID."
|
|
::= { vmwNsxTDataCenterData 63 }
|
|
|
|
vmwNsxTDataCenterIDSEventsCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIDSEventsCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 64 }
|
|
|
|
vmwNsxTDataCenterRemoteSiteName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteSiteNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 65 }
|
|
|
|
vmwNsxTDataCenterBGPSourceIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterBGPSourceIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 66 }
|
|
|
|
vmwNsxTDataCenterRemoteSiteId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteSiteIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 67 }
|
|
|
|
vmwNsxTDataCenterSiteId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSiteIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 68 }
|
|
|
|
vmwNsxTDataCenterSiteName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSiteNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 69 }
|
|
|
|
vmwNsxTDataCenterLrId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLrIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 70 }
|
|
|
|
vmwNsxTDataCenterRxMisses OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxMissesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 71 }
|
|
|
|
vmwNsxTDataCenterRxProcessed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxProcessedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 72 }
|
|
|
|
vmwNsxTDataCenterTxMisses OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxMissesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 73 }
|
|
|
|
vmwNsxTDataCenterTxProcessed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxProcessedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 74 }
|
|
|
|
vmwNsxTDataCenterLrportId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLrportIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router Port UUID."
|
|
::= { vmwNsxTDataCenterData 75 }
|
|
|
|
vmwNsxTDataCenterServiceIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Ip configured for the service running in an NSX-T appliance."
|
|
::= { vmwNsxTDataCenterData 77 }
|
|
|
|
vmwNsxTDataCenterRemoteManagerNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteManagerNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 80 }
|
|
|
|
vmwNsxTDataCenterDirectoryDomain OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDirectoryDomainType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 81 }
|
|
|
|
vmwNsxTDataCenterTimeoutInMinutes OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTimeoutInMinutesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 82 }
|
|
|
|
vmwNsxTDataCenterMaxCapacityThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxCapacityThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 83 }
|
|
|
|
vmwNsxTDataCenterMinCapacityThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMinCapacityThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 84 }
|
|
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxSupportedCapacityCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 85 }
|
|
|
|
vmwNsxTDataCenterLatencySource OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencySourceType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 86 }
|
|
|
|
vmwNsxTDataCenterLatencyThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencyThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 87 }
|
|
|
|
vmwNsxTDataCenterLatencyValue OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencyValueType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 88 }
|
|
|
|
vmwNsxTDataCenterApplianceFQDN OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterApplianceFQDNType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 89 }
|
|
|
|
vmwNsxTDataCenterRemoteApplianceAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteApplianceAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 90 }
|
|
|
|
vmwNsxTDataCenterManagerNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 91 }
|
|
|
|
vmwNsxTDataCenterDisplayedLicenseKey OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDisplayedLicenseKeyType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 92 }
|
|
|
|
vmwNsxTDataCenterEdgeThreadName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeThreadNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 93 }
|
|
|
|
vmwNsxTDataCenterIntentPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIntentPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 94 }
|
|
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallHalfopenFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall TCP half-open connection usage."
|
|
::= { vmwNsxTDataCenterData 95 }
|
|
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallICMPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall ICMP connection usage."
|
|
::= { vmwNsxTDataCenterData 96 }
|
|
|
|
vmwNsxTDataCenterServiceDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 97 }
|
|
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallUDPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall UDP connection usage."
|
|
::= { vmwNsxTDataCenterData 98 }
|
|
|
|
vmwNsxTDataCenterFirewallIPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallIPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall IP connection usage."
|
|
::= { vmwNsxTDataCenterData 99 }
|
|
|
|
vmwNsxTDataCenterDNSId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDNSIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder identifier."
|
|
::= { vmwNsxTDataCenterData 100 }
|
|
|
|
vmwNsxTDataCenterDNSUpstreamIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDNSUpstreamIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder upstream server IP address."
|
|
::= { vmwNsxTDataCenterData 101 }
|
|
|
|
vmwNsxTDataCenterCABundleAgeThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCABundleAgeThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 121 }
|
|
|
|
vmwNsxTDataCenterAPICollectionPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterAPICollectionPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 122 }
|
|
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 123 }
|
|
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 124 }
|
|
|
|
vmwNsxTDataCenterFirewallSNATPortsUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallSNATPortsUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 125 }
|
|
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 126 }
|
|
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 127 }
|
|
|
|
vmwNsxTDataCenterSNATIPAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSNATIPAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 128 }
|
|
|
|
vmwNsxTDataCenterNappClusterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappClusterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 129 }
|
|
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappMessagingLAGThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 130 }
|
|
|
|
vmwNsxTDataCenterNappNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 131 }
|
|
|
|
vmwNsxTDataCenterNappServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 132 }
|
|
|
|
vmwNsxTDataCenterFlowIdentifier OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFlowIdentifierType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 133 }
|
|
|
|
vmwNsxTDataCenterSyncIssueReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSyncIssueReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 134 }
|
|
|
|
vmwNsxTDataCenterQueueName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 135 }
|
|
|
|
vmwNsxTDataCenterQueueSize OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueSizeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 136 }
|
|
|
|
vmwNsxTDataCenterQueueSizeThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueSizeThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 137 }
|
|
|
|
vmwNsxTDataCenterGroupType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterGroupTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 138 }
|
|
|
|
vmwNsxTDataCenterManagerNodeIDS OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeIDSType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 139 }
|
|
|
|
vmwNsxTDataCenterServiceRouterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceRouterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 140 }
|
|
|
|
vmwNsxTDataCenterTransportNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 141 }
|
|
|
|
vmwNsxTDataCenterFromGMPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFromGMPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 142 }
|
|
|
|
vmwNsxTDataCenterToGMPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterToGMPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 143 }
|
|
|
|
vmwNsxTDataCenterNICThroughput OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNICThroughputType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 144 }
|
|
|
|
vmwNsxTDataCenterNICThroughputThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNICThroughputThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 145 }
|
|
|
|
vmwNsxTDataCenterEdgeCryptoDrvName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeCryptoDrvNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 146 }
|
|
|
|
vmwNsxTDataCenterNappNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 147 }
|
|
|
|
-- **********************************************************
|
|
-- AlarmManagement feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTAlarmManagementFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the AlarmManagement feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 16 }
|
|
|
|
vmwNsxTAlarmManagementFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for AlarmManagement feature notifications.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeaturePrefix 0 }
|
|
|
|
vmwNsxTAlarmManagementAlarmServiceOverloaded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Due to heavy volume of alarms reported, the alarm service is temporarily
|
|
overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped
|
|
reporting new alarms; however, syslog entries and SNMP traps (if enabled)
|
|
are still being emitted reporting the underlying event details. When the
|
|
underlying issues causing the heavy volume of alarms are addressed, the
|
|
alarm service will start reporting new alarms again.
|
|
|
|
Action required:
|
|
Review all active alarms using the Alarms page in the NSX UI or using the
|
|
GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each
|
|
active alarm investigate the root cause by following the recommended action
|
|
for the alarm. When sufficient alarms are resolved, the alarm service will
|
|
start reporting new alarms again.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 1 }
|
|
|
|
vmwNsxTAlarmManagementAlarmServiceOverloadedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The heavy volume of alarms has subsided and new alarms are being reported
|
|
again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 2 }
|
|
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarms NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Due to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has
|
|
temporarily stopped reporting alarms of this type. The NSX UI and
|
|
GET /api/v1/alarms NSX API are not reporting new instances of these
|
|
alarms; however, syslog entries and SNMP traps (if enabled) are
|
|
still being emitted reporting the underlying event details. When the
|
|
underlying issues causing the heavy volume of vmwNsxTDataCenterEventId alarms are
|
|
addressed, the alarm service will start reporting new vmwNsxTDataCenterEventId
|
|
alarms when new issues are detected again.
|
|
|
|
Action required:
|
|
Review all active alarms of type vmwNsxTDataCenterEventId using the
|
|
Alarms page in the NSX UI or using the NSX API GET
|
|
/api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED. For each active
|
|
alarm investigate the root cause by following the recommended action
|
|
for the alarm. When sufficient alarms are resolved, the alarm service
|
|
will start reporting new vmwNsxTDataCenterEventId alarms again.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 3 }
|
|
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of
|
|
this type are being reported again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- AuditLogHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTAuditLogHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the AuditLogHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 24 }
|
|
|
|
vmwNsxTAuditLogHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for AuditLogHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At least one of the monitored log files has read-only permissions or has
|
|
incorrect user/group ownership or rsyslog.log is missing on Manager,
|
|
Global Manager, Edge or Public Cloud Gateway nodes.
|
|
|
|
Action required:
|
|
1. On all NSX appliances, for example Manager nodes, Edge nodes, etc.,
|
|
ensure the permissions for the /var/log directory is 775 and the ownership
|
|
is root:syslog.
|
|
2. On Manager and Global Manager nodes, ensure the file permissions
|
|
for auth.log, nsx-audit.log, nsx-audit-write.log, rsyslog.log and syslog
|
|
under /var/log is 640 and ownership is syslog:admin.
|
|
3. On Edge and Public Cloud Gateway nodes, ensure the file permissions
|
|
for rsyslog.log and syslog under /var/log is 640 and ownership is syslog:admin.
|
|
4. On ESXi host nodes, ensure the file permissions of auth.log, nsx-syslog.log
|
|
and syslog.log under /var/log is 755 and ownership is root:root.
|
|
5. On KVM host nodes, ensure the file permissions of auth.log and syslog
|
|
under /var/log is 775 and ownership is root:syslog.
|
|
6. If any of these files have incorrect permissions or ownership, invoke the
|
|
commands `chmod <mode> <path>` and `chown <user>:<group> <path>`.
|
|
7. If rsyslog.log is missing on Manager, Global Manager, Edge or Public
|
|
Cloud Gateway nodes, invoke the NSX CLI command `restart service syslog`
|
|
which restarts the logging service and regenerates /var/log/rsyslog.log.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 1 }
|
|
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All monitored log files have the correct file permissions and ownership
|
|
and rsyslog.log exists on Manager, Global Manager, Edge or Public
|
|
Cloud Gateway nodes.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 2 }
|
|
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Log messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
|
|
cannot be delivered possibly due to an unresolvable FQDN, an invalid TLS
|
|
certificate or missing NSX appliance iptables rule.
|
|
|
|
Action required:
|
|
1. Ensure that vmwNsxTDataCenterHostnameOrIPAddressWithPort is the correct hostname or
|
|
IP address and port.
|
|
2. If the logging server is specified using a FQDN, ensure the FQDN is resolvable
|
|
from the NSX appliance using the NSX CLI command `nslookup <fqdn>`. If not
|
|
resolvable, verify the correct FQDN is specified and the network DNS server has
|
|
the required entry for the FQDN.
|
|
3. If the logging server is configured to use TLS, verify the specified certificate
|
|
is valid. For example, ensure the logging server is actually using the certificate
|
|
or verify the certificate has not expired using the openssl command
|
|
`openssl x509 -in <cert-file-path> -noout -dates`.
|
|
4. NSX appliances use iptables rules to explicitly allow outgoing traffic. Verify
|
|
the iptables rule for the logging server is configured properly by invoking the
|
|
NSX CLI command `verify logging-servers` which re-configures logging server
|
|
iptables rules as needed.
|
|
5. If for any reason the logging server is misconfigured, it should be deleted
|
|
using the NSX CLI `del logging-server <hostname-or-ip-address[:port]>
|
|
proto <proto> level <level>` command and re-added with the correct configuration.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 3 }
|
|
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
|
|
appear correct.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Capacity feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCapacityFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Capacity feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 22 }
|
|
|
|
vmwNsxTCapacityFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Capacity feature notifications.
|
|
"
|
|
::= { vmwNsxTCapacityFeaturePrefix 0 }
|
|
|
|
vmwNsxTCapacityMaximumCapacity NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum supported
|
|
count of vmwNsxTDataCenterMaxSupportedCapacityCount.
|
|
|
|
Action required:
|
|
Ensure that the number of NSX objects created is within the limits
|
|
supported by NSX. If there are any unused objects, delete them using the
|
|
respective NSX UI or API from the system.
|
|
Consider increasing the form factor of all Manager nodes and/or Edge
|
|
nodes. Note that the form factor of each node type should be the
|
|
same. If not the same, the capacity limits for the lowest form factor
|
|
deployed are used.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 1 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum supported count of
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 2 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum capacity
|
|
threshold of vmwNsxTDataCenterMaxCapacityThreshold%.
|
|
|
|
Action required:
|
|
Navigate to the capacity page in the NSX UI and review current usage versus
|
|
threshold limits. If the current usage is expected, consider increasing the
|
|
maximum threshold values. If the current usage is unexpected, review the
|
|
network policies configured to decrease usage at or below the maximum threshold.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 3 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityThresholdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum capacity threshold
|
|
of vmwNsxTDataCenterMaxCapacityThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 4 }
|
|
|
|
vmwNsxTCapacityMinimumCapacityThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum capacity
|
|
threshold of vmwNsxTDataCenterMinCapacityThreshold%.
|
|
|
|
Action required:
|
|
Navigate to the capacity page in the NSX UI and review current usage versus
|
|
threshold limits. If the current usage is expected, consider increasing the
|
|
minimum threshold values. If the current usage is unexpected, review the
|
|
network policies configured to decrease usage at or below the minimum threshold.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 5 }
|
|
|
|
vmwNsxTCapacityMinimumCapacityThresholdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the minimum capacity threshold
|
|
of vmwNsxTDataCenterMinCapacityThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Certificates feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCertificatesFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Certificates feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 3 }
|
|
|
|
vmwNsxTCertificatesFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Certificates feature notifications.
|
|
"
|
|
::= { vmwNsxTCertificatesFeaturePrefix 0 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateRecommended NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCABundleAgeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
|
|
vmwNsxTDataCenterCABundleAgeThreshold days ago.
|
|
Update for the trusted CA bundle is recommended.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the trusted CA bundle are updated
|
|
to use a recently-updated trusted CA bundle. Unless it is system-provided
|
|
bundle, the bundle can be updated using the
|
|
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
Once the expired bundle is no longer in use, it should be deleted (if not
|
|
system-provided) by invoking the
|
|
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 7 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateRecommendedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
|
|
in use.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 8 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateSuggested NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCABundleAgeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
|
|
vmwNsxTDataCenterCABundleAgeThreshold days ago.
|
|
Update for the trusted CA bundle is suggested.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the trusted CA bundle are updated
|
|
to use a recently-updated trusted CA bundle. Unless it is system-provided
|
|
bundle, the bundle can be updated using the
|
|
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
Once the expired bundle is no longer in use, it should be deleted (if not
|
|
system-provided) by invoking the
|
|
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 9 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateSuggestedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
|
|
in use.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 10 }
|
|
|
|
vmwNsxTCertificatesCertificateExpirationApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId is approaching expiration.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expiring certificate. Once the expiring
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 1 }
|
|
|
|
vmwNsxTCertificatesCertificateExpirationApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
approaching expiration.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 2 }
|
|
|
|
vmwNsxTCertificatesCertificateExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId has expired.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expired certificate. Once the expired
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
If the expired certificate is used by NAPP Platform,
|
|
the connection is broken between NSX and NAPP Platform.
|
|
Please check the NAPP Platform troubleshooting document
|
|
to use a self-signed NAPP CA certificate for recovering the connection.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 3 }
|
|
|
|
vmwNsxTCertificatesCertificateExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 4 }
|
|
|
|
vmwNsxTCertificatesCertificateIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId is about to expire.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expiring certificate. Once the expiring
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 5 }
|
|
|
|
vmwNsxTCertificatesCertificateIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Clustering feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTClusteringFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Clustering feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 40 }
|
|
|
|
vmwNsxTClusteringFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Clustering feature notifications.
|
|
"
|
|
::= { vmwNsxTClusteringFeaturePrefix 0 }
|
|
|
|
vmwNsxTClusteringClusterDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group member vmwNsxTDataCenterManagerNodeId of service vmwNsxTDataCenterGroupType is down.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command 'get cluster status' to view the status
|
|
of group members of the cluster.
|
|
2. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
|
|
/api/v1/node/services/<service_name>/status NSX API or the
|
|
`get service <service_name>` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
|
|
the `restart service <service_name>` NSX CLI to restart the service.
|
|
3. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 1 }
|
|
|
|
vmwNsxTClusteringClusterDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group member vmwNsxTDataCenterManagerNodeId of vmwNsxTDataCenterGroupType is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 2 }
|
|
|
|
vmwNsxTClusteringClusterUnavailable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are down.
|
|
|
|
Action required:
|
|
1. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
|
|
/api/v1/node/services/<service_name>/status NSX API or the
|
|
`get service <service_name>` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
|
|
the `restart service <service_name>` NSX CLI to restart the service.
|
|
2. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 3 }
|
|
|
|
vmwNsxTClusteringClusterUnavailableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- CniHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCniHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the CniHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 10 }
|
|
|
|
vmwNsxTCniHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for CniHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTCniHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus cannot communicate with the Manager node.
|
|
|
|
Action required:
|
|
The hyperbus vmkernel interface (vmk50) may be missing. Please refer to
|
|
Knowledge Base article https://kb.vmware.com/s/article/67432.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 3 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus can communicate with the Manager node.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Communication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Communication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 35 }
|
|
|
|
vmwNsxTCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Communication feature notifications.
|
|
"
|
|
::= { vmwNsxTCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
|
|
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
|
|
interface via ping. If they are not pingable, check for flakiness in network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
Note: Please note that this alarm is not critical and should be resolved. GSS need not be
|
|
contacted for the notification of this alarm unless the alarm remains unresolved over an
|
|
extended period of time.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 7 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
|
|
vmwNsxTDataCenterApplianceAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 8 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
|
|
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
|
|
interface via ping. If they are not pingable, check for flakiness in network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>.
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 9 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
|
|
vmwNsxTDataCenterApplianceAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 10 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service vmwNsxTDataCenterCentralControlPlaneId to Transport node vmwNsxTDataCenterEntityId down for at
|
|
least three minutes from Controller service's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
|
|
Transport node vmwNsxTDataCenterEntityId. interface via ping. If they are not pingable, check for flakiness in
|
|
network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service vmwNsxTDataCenterCentralControlPlaneId is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
Note: Please note that this alarm is not critical and should be resolved. GSS need not be
|
|
contacted for the notification of this alarm unless the alarm remains unresolved over an
|
|
extended period of time.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 11 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service vmwNsxTDataCenterCentralControlPlaneId restores connection to Transport node vmwNsxTDataCenterEntityId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 12 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service vmwNsxTDataCenterCentralControlPlaneId to Transport node vmwNsxTDataCenterEntityId down for at
|
|
least 15 minutes from Controller service's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
|
|
Transport node vmwNsxTDataCenterEntityId. interface via ping. If they are not pingable, check for flakiness in
|
|
network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service vmwNsxTDataCenterCentralControlPlaneId is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 19 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service vmwNsxTDataCenterCentralControlPlaneId restores connection to Transport node vmwNsxTDataCenterEntityId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 20 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is down for 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the
|
|
Transport node vmwNsxTDataCenterTransportNodeId
|
|
and master Manager node. Also ensure no firewalls are blocking traffic
|
|
between the nodes. Ensure the messaging manager service is running on
|
|
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
|
|
If the messaging manager is not running, restart it by
|
|
invoking the command `/etc/init.d/messaging-manager restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 13 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 14 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is down for 15 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the
|
|
Transport node vmwNsxTDataCenterTransportNodeId
|
|
and master Manager nodes. Also ensure no firewalls are blocking traffic
|
|
between the nodes. Ensure the messaging manager service is running on
|
|
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
|
|
If the messaging manager is not running, restart it by
|
|
invoking the command `/etc/init.d/messaging-manager restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 25 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 26 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is down for 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the Manager nodes
|
|
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
|
|
and no firewalls are blocking traffic between the nodes.
|
|
On Windows Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
|
|
in the Windows PowerShell. If it is not running, restart it by
|
|
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
|
|
On all other Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
|
|
If it is not running, restart it by invoking the command
|
|
`/etc/init.d/nsx-proxy restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 1 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 2 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is down for 15 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the Manager nodes
|
|
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
|
|
and no firewalls are blocking traffic between the nodes.
|
|
On Windows Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
|
|
in the Windows PowerShell. If it is not running, restart it by
|
|
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
|
|
On all other Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
|
|
If it is not running, restart it by invoking the command
|
|
`/etc/init.d/nsx-proxy restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 5 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 6 }
|
|
|
|
vmwNsxTCommunicationManagerClusterLatencyHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterRemoteApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
|
|
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is more than 10ms for the last 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there are no firewall rules blocking ping traffic between the Manager nodes.
|
|
If there are other high bandwidth servers and applications sharing the local network,
|
|
consider moving these to a different network.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 17 }
|
|
|
|
vmwNsxTCommunicationManagerClusterLatencyHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterRemoteApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
|
|
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is within 10ms.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 18 }
|
|
|
|
vmwNsxTCommunicationManagerControlChannelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The communication between the management function and the control
|
|
function has failed on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
|
|
|
|
Action required:
|
|
1. On Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress), please invoke the
|
|
following NSX CLI command: `get service applianceproxy` to check the status
|
|
of the service periodically for 60 minutes.
|
|
|
|
2. If the service is not running for more than 60 minutes, invoke
|
|
the following NSX CLI command: `restart service applianceproxy` and recheck the
|
|
status. If the service is still down, please contact VMware support.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 3 }
|
|
|
|
vmwNsxTCommunicationManagerControlChannelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The communication between the management function and the control function
|
|
has been restored on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 4 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNLookupFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceFQDN
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with FQDN
|
|
vmwNsxTDataCenterApplianceFQDN and the publish_fqdns flag was set.
|
|
|
|
Action required:
|
|
1. Assign correct FQDNs to all Manager nodes and verify the DNS
|
|
configuration is correct for successful lookup of all Manager
|
|
nodes' FQDNs.
|
|
2. Alternatively, disable the use of FQDNs by invoking the NSX API
|
|
PUT /api/v1/configs/management with publish_fqdns set to false in the
|
|
request body. After that calls from Transport nodes and from Federation
|
|
to Manager nodes in this cluster will use only IP addresses.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 21 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNLookupFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceFQDN
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FQDN lookup succeeded for Manager node vmwNsxTDataCenterEntityId with FQDN
|
|
vmwNsxTDataCenterApplianceFQDN or the publish_fqdns flag was cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 22 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with IP address
|
|
vmwNsxTDataCenterApplianceAddress and the publish_fqdns flag was set.
|
|
|
|
Action required:
|
|
1. Assign correct FQDNs to all Manager nodes and verify the DNS
|
|
configuration is correct for successful reverse lookup of the Manager
|
|
node's IP address.
|
|
2. Alternatively, disable the use of FQDNs by invoking the NSX API
|
|
PUT /api/v1/configs/management with publish_fqdns set to false in the
|
|
request body. After that calls from Transport nodes and from Federation
|
|
to Manager nodes in this cluster will use only IP addresses.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 23 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse DNS lookup succeeded for Manager node vmwNsxTDataCenterEntityId with IP address
|
|
vmwNsxTDataCenterApplianceAddress or the publish_fqdns flag was cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 24 }
|
|
|
|
-- **********************************************************
|
|
-- DHCP feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDHCPFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DHCP feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 20 }
|
|
|
|
vmwNsxTDHCPFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DHCP feature notifications.
|
|
"
|
|
::= { vmwNsxTDHCPFeaturePrefix 0 }
|
|
|
|
vmwNsxTDHCPPoolLeaseAllocationFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The addresses in IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId have
|
|
been exhausted. The last DHCP request has failed and future requests will
|
|
fail.
|
|
|
|
Action required:
|
|
Review the DHCP pool configuration in the NSX UI or on the Edge node where
|
|
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
|
|
Also review the current active leases on the Edge node by invoking the NSX
|
|
CLI command `get dhcp lease`. Compare the leases to the number of active
|
|
VMs. Consider reducing the lease time on the DHCP server configuration if
|
|
the number of VMs are low compared to the number of active leases. Also
|
|
consider expanding the pool range for the DHCP server by visiting the
|
|
Networking | Segments | Segment page in the NSX UI.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 1 }
|
|
|
|
vmwNsxTDHCPPoolLeaseAllocationFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId is no longer exhausted.
|
|
A lease is successfully allocated to the last DHCP request.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 2 }
|
|
|
|
vmwNsxTDHCPPoolOverloaded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId,
|
|
vmwNsxTDataCenterDHCPPoolUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId usage is approaching
|
|
exhaustion with vmwNsxTDataCenterDHCPPoolUsage% IPs allocated.
|
|
|
|
Action required:
|
|
Review the DHCP pool configuration in the NSX UI or on the Edge node where
|
|
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
|
|
Also review the current active leases on the Edge node by invoking the NSX
|
|
CLI command `get dhcp lease`. Compare the leases to the number of active
|
|
VMs. Consider reducing the lease time on the DHCP server configuration if
|
|
the number of VMs are low compared to the number of active leases. Also
|
|
consider expanding the pool range for the DHCP server by visiting the
|
|
Networking | Segments | Segment page in the NSX UI.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 3 }
|
|
|
|
vmwNsxTDHCPPoolOverloadedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId has fallen below the
|
|
high usage threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- DistributedFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDistributedFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DistributedFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 31 }
|
|
|
|
vmwNsxTDistributedFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DistributedFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts. Please
|
|
review the security design for optimization. For example, use the apply-to
|
|
configuration if the rules are not applicable to the entire datacenter.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 1 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 2 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
View the current DFW memory usage by invoking the NSX CLI command
|
|
`get firewall thresholds` on the host. Consider re-balancing the
|
|
workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 3 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 4 }
|
|
|
|
vmwNsxTDistributedFirewallDFWSessionCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has
|
|
reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the network traffic load level of the workloads on the host.
|
|
Consider re-balancing the workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 5 }
|
|
|
|
vmwNsxTDistributedFirewallDFWSessionCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 6 }
|
|
|
|
vmwNsxTDistributedFirewallDFWVmotionFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host
|
|
vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been
|
|
disconnected.
|
|
|
|
Action required:
|
|
Check VMs on the host in NSX Manager, manually repush the DFW configuration
|
|
through NSX Manager UI. The DFW policy to be repushed can be traced by the
|
|
DFW filter vmwNsxTDataCenterEntityId. Also consider finding the VM to which the DFW filter
|
|
is attached and restart it.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 7 }
|
|
|
|
vmwNsxTDistributedFirewallDFWVmotionFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host
|
|
vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure
|
|
cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- DistributedIDSIPS feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDistributedIDSIPSFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DistributedIDSIPS feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 33 }
|
|
|
|
vmwNsxTDistributedIDSIPSFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DistributedIDSIPS feature notifications.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeaturePrefix 0 }
|
|
|
|
vmwNsxTDistributedIDSIPSMaxEventsReached NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
|
|
which is higher than the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
|
|
|
|
Action required:
|
|
There is no manual intervention required. A purge job will kick in automatically
|
|
every 3 minutes and delete 10% of the older records to bring the total intrusion events
|
|
count in the system to below the threshold value of 1.5 million events.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 3 }
|
|
|
|
vmwNsxTDistributedIDSIPSMaxEventsReachedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
|
|
which is below the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 4 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 7 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 8 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 21 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high
|
|
threshold value of 85%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 22 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very
|
|
high threshold value of 95%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 9 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the very
|
|
high threshold value of 95%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 10 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is enabled via NSX policy and IDPS rules are configured, but
|
|
NSX-IDPS engine is down.
|
|
|
|
Action required:
|
|
1. Check /var/log/nsx-syslog.log to see if there are errors reported.
|
|
2. Invoke the NSX CLI command `get ids engine status` to check
|
|
if NSX Distributed IDPS is in disabled state. If so,
|
|
invoke `/etc/init.d/nsx-idps start` to start the service.
|
|
3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running.
|
|
If not, invoke `/etc/init.d/nsx-vdpi start` to start the service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 13 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is in one of the cases below.
|
|
1. NSX IDPS is disabled via NSX policy.
|
|
2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and
|
|
NSX IDPS has been enabled and IDPS rules are configured
|
|
via NSX Policy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 14 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 15 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold
|
|
value of 75%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 16 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 17 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 18 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the
|
|
very high threshold value of 95%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 19 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the very high
|
|
threshold value of 95%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 20 }
|
|
|
|
-- **********************************************************
|
|
-- DNS feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDNSFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DNS feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 30 }
|
|
|
|
vmwNsxTDNSFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DNS feature notifications.
|
|
"
|
|
::= { vmwNsxTDNSFeaturePrefix 0 }
|
|
|
|
vmwNsxTDNSForwarderDisabled NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is disabled.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
|
|
if the DNS forwarder is in the disabled state.
|
|
2. Use NSX Policy API or Manager API to enable the DNS forwarder it
|
|
should not be in the disabled state.
|
|
"
|
|
::= { vmwNsxTDNSFeature 1 }
|
|
|
|
vmwNsxTDNSForwarderDisabledClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is enabled.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 2 }
|
|
|
|
vmwNsxTDNSForwarderDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the
|
|
identified DNS Forwarder that is currently enabled.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
|
|
if the DNS forwarder is in down state.
|
|
2. Check /var/log/syslog to see if there are errors reported.
|
|
3. Collect a support bundle and contact the NSX support team.
|
|
"
|
|
::= { vmwNsxTDNSFeature 3 }
|
|
|
|
vmwNsxTDNSForwarderDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is running again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 4 }
|
|
|
|
vmwNsxTDNSForwarderUpstreamServerTimeout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath,
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response
|
|
from upstream server vmwNsxTDataCenterDNSUpstreamIP. Compute instance connectivity to
|
|
timed out FQDNs may be impacted.
|
|
|
|
Action required:
|
|
1. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
|
|
address=<address>&server_ip=vmwNsxTDataCenterDNSUpstreamIP&source_ip=<source_ip>.
|
|
This API request triggers a DNS lookup to the upstream server in the
|
|
DNS forwarder's network namespace. <address> is the IP address or FQDN
|
|
in the same domain as the upstream server. <source_ip> is an IP address
|
|
in the upstream server's zone.
|
|
If the API returns a connection timed out response, there is likely a
|
|
network error or upstream server problem. Please check why DSN lookups
|
|
are not reaching the upstream server or why the upstream server is not
|
|
returning a response. If the API response indicates the upstream server
|
|
is answering, proceed to step 2.
|
|
2. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
|
|
address=<address>.
|
|
This API request triggers a DNS lookup to the DNS forwarder. If the API
|
|
returns a valid response, the upstream server may have recovered and this
|
|
alarm should get resolved within a few minutes. If the API returns a
|
|
connection timed out response, proceed to step 3.
|
|
3. Invoke the NSX CLI command `get dns-forwarder vmwNsxTDataCenterDNSId live-debug
|
|
server-ip vmwNsxTDataCenterDNSUpstreamIP`.
|
|
This command triggers live debugging on the upstream server and logs
|
|
details and statistics showing why the DNS forwarder is not getting a
|
|
response.
|
|
"
|
|
::= { vmwNsxTDNSFeature 5 }
|
|
|
|
vmwNsxTDNSForwarderUpstreamServerTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath,
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Edge feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEdgeFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Edge feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 45 }
|
|
|
|
vmwNsxTEdgeFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Edge feature notifications.
|
|
"
|
|
::= { vmwNsxTEdgeFeaturePrefix 0 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not
|
|
match the policy intent configuration. The Edge node configuration visible to user
|
|
on UI or API is not same as what is realized. The realized Edge node changes made by
|
|
user outside of NSX Manager are shown in the details of this alarm and any edits in
|
|
UI or API will overwrite the realized configuration. Fields that differ for Edge node
|
|
settings and vSphere configuration are listed in runtime data vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
|
|
|
|
Action required:
|
|
Please review the node settings and vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Please follow one of following actions to resolve alarm -
|
|
1. Manually update Edge Transport Node setting Policy intent using
|
|
API : PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
|
|
2. Accept intent or vSphere realized Edge node configuration or realized
|
|
Edge node settings for this Edge Transport Node through Edge Transport Node
|
|
resolver to resolve this alarm.
|
|
3. Resolve alarm by accepting the Edge node settings and vSphere realized configuration
|
|
using refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 1 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 2 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy
|
|
intent configuration. The Edge node configuration visible to user on
|
|
UI or API is not same as what is realized. The realized Edge node changes
|
|
made by user outside of NSX Manager are shown in the details of this alarm
|
|
and any edits in UI or API will overwrite the realized configuration.
|
|
Fields that differ for the Edge node are listed in runtime data
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
|
|
|
|
Action required:
|
|
Please review the node settings of this Edge transport node vmwNsxTDataCenterEntityId.
|
|
Please follow one of following actions to resolve alarm -
|
|
1. Manually update Edge transport node setting Policy intent
|
|
using API - PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
|
|
2. Accept intent or realized Edge node settings for this Edge transport node
|
|
through Edge transport node resolver to resolve this alarm.
|
|
3. Resolve alarm by accepting the Edge node settings configuration using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 3 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 4 }
|
|
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy
|
|
intent configuration. The Edge node configuration visible to user on UI or API
|
|
is not same as what is realized. The realized Edge node changes made by user
|
|
outside of NSX Manager are shown in the details of this alarm and any edits
|
|
in UI or API will overwrite the realized configuration. Fields that differ for
|
|
the Edge node are listed in runtime data vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
|
|
|
|
Action required:
|
|
Please review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Please follow one of following actions to resolve alarm -
|
|
1. Accept intent or vSphere realized Edge node configuration for this Edge Transport Node
|
|
through Edge Transport Node resolver to resolve this alarm.
|
|
2. Resolve alarm by accepting the Edge node vSphere realized configuration using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 5 }
|
|
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 6 }
|
|
|
|
vmwNsxTEdgeEdgevSphereLocationMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration
|
|
on vSphere does not match the policy intent configuration. The Edge node configuration visible to
|
|
user on UI or API is not same as what is realized. The realized Edge node changes made by user outside
|
|
of NSX Manager are shown in the details of this alarm. Fields that differ for the Edge node are listed
|
|
in runtime data vmwNsxTDataCenterEdgevSphereLocationMismatchReason
|
|
|
|
Action required:
|
|
Please review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Please follow one of following actions to resolve alarm -
|
|
1. Resolve alarm by accepting the Edge node vSphere realized config using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
2. If you want to return to the previous location please use
|
|
NSX Redeploy API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=redeploy.
|
|
vMotion back to the original host is not supported.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 7 }
|
|
|
|
vmwNsxTEdgeEdgevSphereLocationMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- EdgeHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEdgeHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the EdgeHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 2 }
|
|
|
|
vmwNsxTEdgeHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for EdgeHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlocked NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeThreadName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is deadlocked.
|
|
|
|
Action required:
|
|
Restart the dataplane service by invoking the NSX CLI command `restart service dataplane`.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 45 }
|
|
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeThreadName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is free from deadlock.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 46 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 1 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 2 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 3 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 4 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failed to enable the datapath on the Edge node after three attempts.
|
|
|
|
Action required:
|
|
Ensure the Edge node's connectivity to the Manager node is healthy. From
|
|
the Edge node's NSX CLI, invoke the command `get services` to check the
|
|
health of services. If the dataplane service is stopped, invoke the
|
|
command `start service dataplane` to start it.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 21 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Datapath on the Edge node has been successfully enabled.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 22 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the high
|
|
threshold for at least two minutes.
|
|
|
|
Action required:
|
|
Review the CPU statistics on the Edge node by invoking the NSX CLI command
|
|
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
|
|
usage is expected with higher packet rates. Consider increasing the Edge
|
|
appliance form factor size and rebalancing services on this Edge node to
|
|
other Edge nodes in the same cluster or other Edge clusters.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 17 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
|
|
high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 18 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the very high
|
|
threshold for at least two minutes.
|
|
|
|
Action required:
|
|
Review the CPU statistics on the Edge node by invoking the NSX CLI command
|
|
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
|
|
usage is expected with higher packet rates. Consider increasing the Edge
|
|
appliance form factor size and rebalancing services on this Edge node to
|
|
other Edge nodes in the same cluster or other Edge clusters.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 19 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
|
|
very high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 20 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is down.
|
|
|
|
Action required:
|
|
Upgrade the Edge node as needed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 23 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 24 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Log in as the root user and invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl mempool/show` and
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl memory/show malloc_heap` to
|
|
check DPDK memory usage.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 25 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 26 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
|
|
the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
Examine the traffic thoughput levels on the NIC and determine whether
|
|
configuration changes are needed. The 'get dataplane thoughput <seconds>'
|
|
command can be used to monitor throughput.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 49 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
|
|
is below the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 50 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
|
|
the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
Examine the traffic thoughput levels on the NIC and determine whether
|
|
configuration changes are needed. The 'get dataplane thoughput <seconds>'
|
|
command can be used to monitor throughput.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 51 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
|
|
is below the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 52 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 9 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 10 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 11 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the
|
|
very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 12 }
|
|
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is above the high threshold
|
|
for over two minutes.
|
|
|
|
Action required:
|
|
Log in as the root user and invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/show` and check
|
|
if neigh cache usage is normal. If it is normal, invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/set_param max_entries`
|
|
to increase the ARP table size.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 27 }
|
|
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global arp table usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 28 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 5 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 6 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 7 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 8 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is down.
|
|
|
|
Action required:
|
|
On the Edge node confirm if the NIC link is physically down by invoking
|
|
the NSX CLI command `get interfaces`. If it is down, verify the cable
|
|
connection.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 29 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 30 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterRxMisses,
|
|
vmwNsxTDataCenterRxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer has overflowed by
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
|
|
The missed packet count is vmwNsxTDataCenterRxMisses and processed packet count
|
|
is vmwNsxTDataCenterRxProcessed.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get dataplane cpu stats`, and check
|
|
1. If cpu usage is high, i.e., > 90%, then take a packet capture on
|
|
the interface using the command `start capture interface
|
|
<interface-name> direction input` or `start capture interface
|
|
<interface-name> direction input core <core-id>` (to capture
|
|
packets ingressing on specific core whose usage is high).
|
|
Then analyze the capture to see if there are majority of
|
|
fragmented packets or ipsec packets. If yes, then it is expected
|
|
behavior. If not probably datapath is stuck processing other bookkeeping
|
|
operations and if alarm lasts or more than 2-3 min, contact VMware Support.
|
|
2. If cpu usage is not high, i.e., < 90%, then check if rx pps is high
|
|
using the command `get dataplane cpu stats` (just to make sure the
|
|
traffic rate is increasing). Then increase the ring size by 1024
|
|
using the command `set dataplane ring-size rx <ring-size>`.
|
|
NOTE - The continuous increase of ring size by 1024 factor can lead
|
|
to some performance issue due to cache line thrashing internally.
|
|
If even after increasing the ring size, the issue persists then
|
|
it is an indication that edge needs a larger form factor deployment
|
|
to accommodate the traffic.
|
|
3. If the alarm keeps on flapping i.e., triggers and resolves very soon,
|
|
then it is due to bursty traffic. In this case check if rx pps as
|
|
described above, if it is not high during the alarm active period
|
|
then contact VMware Support. If pps is high it confirms bursty traffic.
|
|
Consider suppressing the alarm.
|
|
NOTE - There is no specific benchmark to decide what is regarded as a
|
|
high pps value. It depends on infrastructure and type of traffic.
|
|
The comparison can be made by noting down when alarm is inactive and
|
|
when it is active.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 31 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer usage on Edge node
|
|
vmwNsxTDataCenterEntityId is no longer overflowing.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 32 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterTxMisses,
|
|
vmwNsxTDataCenterTxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer has overflowed by
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
|
|
The missed packet count is vmwNsxTDataCenterTxMisses and processed packet count
|
|
is vmwNsxTDataCenterTxProcessed.
|
|
|
|
Action required:
|
|
1. If a lot of VMs are accommodated along with edge by the hypervisor
|
|
then edge VM might not get time to run, hence the packets might
|
|
not be retrieved by hypervisor. Then probably migrating the edge VM
|
|
to a host with fewer VMs.
|
|
2. Increase the ring size by 1024 using the command `set dataplane
|
|
ring-size tx <ring-size>`. If even after increasing the ring size,
|
|
the issue persists then contact VMware Support as the ESX side
|
|
transmit ring buffer might be of lower value. If there is no
|
|
issue on ESX side, it indicates the edge needs to be scaled to
|
|
a larger form factor deployment to accommodate the traffic.
|
|
3. If the alarm keeps on flapping, i.e., triggers and resolves very soon,
|
|
then it is due to bursty traffic. In this case check if tx pps using
|
|
the command `get dataplane cpu stats`. If it is not high during the
|
|
alarm active period then contact VMware Support.
|
|
If pps is high it confirms bursty traffic. Consider suppressing the
|
|
alarm.
|
|
NOTE - There is no specific benchmark to decide what is regarded as a
|
|
high pps value. It depends on infrastructure and type of traffic.
|
|
The comparison can be made by noting down when alarm is inactive and
|
|
when it is active.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 33 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer usage on Edge node
|
|
vmwNsxTDataCenterEntityId is no longer overflowing.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 34 }
|
|
|
|
vmwNsxTEdgeHealthFailureDomainDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All members of failure domain vmwNsxTDataCenterTransportNodeId are down.
|
|
|
|
Action required:
|
|
1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, check the connectivity
|
|
to the management and control planes by invoking the NSX CLI command
|
|
`get managers` and `get controllers`.
|
|
2. Invoke the NSX CLI command `get interface eth0` to check the management
|
|
interface status.
|
|
3. Invoke the CLI `get services` to check the core services status like
|
|
dataplane/local-controller/nestdb/router, etc.
|
|
4. Inspect the /var/log/syslog to find the suspecting error.
|
|
5. Reboot the Edge node.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 53 }
|
|
|
|
vmwNsxTEdgeHealthFailureDomainDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All members of failure domain vmwNsxTDataCenterTransportNodeId are reachable.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 54 }
|
|
|
|
vmwNsxTEdgeHealthStorageError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partitions on the Edge node are in
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
Examine the read-only partition to see if reboot resolves the issue
|
|
or the disk needs to be replaced. Contact GSS for more information.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 37 }
|
|
|
|
vmwNsxTEdgeHealthStorageErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partitions on the Edge node have recovered from
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 38 }
|
|
|
|
-- **********************************************************
|
|
-- EndpointProtection feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEndpointProtectionFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the EndpointProtection feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 13 }
|
|
|
|
vmwNsxTEndpointProtectionFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for EndpointProtection feature notifications.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeaturePrefix 0 }
|
|
|
|
vmwNsxTEndpointProtectionEAMStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Start the ESX Agent Manager (EAM) service. SSH into vCenter and invoke
|
|
the command `service vmware-eam start`.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 1 }
|
|
|
|
vmwNsxTEndpointProtectionEAMStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up
|
|
or compute manager vmwNsxTDataCenterEntityId has been removed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 2 }
|
|
|
|
vmwNsxTEndpointProtectionPartnerChannelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
|
|
is down.
|
|
|
|
Action required:
|
|
Refer to https://kb.vmware.com/s/article/85844 and make sure
|
|
that Partner SVM vmwNsxTDataCenterEntityId is re-connected to the host module.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 3 }
|
|
|
|
vmwNsxTEndpointProtectionPartnerChannelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
|
|
is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Federation feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTFederationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Federation feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 32 }
|
|
|
|
vmwNsxTFederationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Federation feature notifications.
|
|
"
|
|
::= { vmwNsxTFederationFeaturePrefix 0 }
|
|
|
|
vmwNsxTFederationGMToGMLatencyWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency is higher than expected between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity.
|
|
"
|
|
::= { vmwNsxTFederationFeature 17 }
|
|
|
|
vmwNsxTFederationGMToGMLatencyWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency is below expected levels between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 18 }
|
|
|
|
vmwNsxTFederationGMToGMSplitBrain NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterActiveGlobalManagers
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multiple Global Manager nodes are active: vmwNsxTDataCenterActiveGlobalManagers. Only one Global Manager node must be active
|
|
at any time.
|
|
|
|
Action required:
|
|
Configure only one Global Manager node as active and all other Global Manager nodes as standby.
|
|
"
|
|
::= { vmwNsxTFederationFeature 9 }
|
|
|
|
vmwNsxTFederationGMToGMSplitBrainClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterActiveGlobalManager
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global Manager node vmwNsxTDataCenterActiveGlobalManager is the only active Global Manager node now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 10 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath cannot
|
|
synchronize for more than 5 minutes.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
|
|
"
|
|
::= { vmwNsxTFederationFeature 19 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 20 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath can not synchronize.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
|
|
"
|
|
::= { vmwNsxTFederationFeature 21 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 22 }
|
|
|
|
vmwNsxTFederationGMToLMLatencyWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterLatencyThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
|
|
vmwNsxTDataCenterLatencyValue which is above the threshold value of vmwNsxTDataCenterLatencyThreshold.
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping.
|
|
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
|
|
3. Check /var/log/async-replicator/ar.log to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 27 }
|
|
|
|
vmwNsxTFederationGMToLMLatencyWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterLatencyThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
|
|
vmwNsxTDataCenterLatencyValue which below the threshold value of vmwNsxTDataCenterLatencyThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 28 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterSyncIssueReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
failed for the vmwNsxTDataCenterFlowIdentifier for an extended period. Reason: vmwNsxTDataCenterSyncIssueReason.
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported. 5. Collect a support bundle and contact the NSX support team.
|
|
"
|
|
::= { vmwNsxTFederationFeature 23 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 24 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterSyncIssueReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the
|
|
vmwNsxTDataCenterFlowIdentifier. Reason: vmwNsxTDataCenterSyncIssueReason
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping. 2. Ensure port TCP/1236 traffic is allowed between the local and remote sites. 3. Ensure the async-replicator service is running on both local and remote sites. Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the `get service async_replicator` NSX CLI command to determine if the service is running. If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or the `restart service async_replicator` NSX CLI to restart the service. 4. Check /var/log/async-replicator/ar.log to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 25 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 26 }
|
|
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgress NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config import from site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is in progress. However site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is restored
|
|
from backup by the administrator leaving it in an inconsistent state.
|
|
|
|
Action required:
|
|
1. Log in to NSX Global Manager appliance CLI.
|
|
2. Switch to root.
|
|
3. Invoke the NSX API DELETE http://localhost:64440/gm/api/v1/infra/sites/<site-name>/onboarding/status in local mode,
|
|
this will delete site on-boarding status for Global Manager.
|
|
4. Re-initiate config on-boarding again.
|
|
"
|
|
::= { vmwNsxTFederationFeature 31 }
|
|
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config inconsistency at site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 32 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
failed for more than 5 minutes.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
|
|
state between the remote locations. If a remote location is connected but not synchronized,
|
|
it is possible that the location is still in the process of master resolution. In
|
|
this case, wait for around 10 seconds and try invoking the CLI again to
|
|
check for the state of the remote location. If a location is disconnected, try the next
|
|
step.
|
|
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
|
|
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
|
|
check for flakiness in WAN connectivity. If there are no physical network
|
|
connectivity issues, try the next step.
|
|
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
|
|
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
|
|
communication errors. In addition, also look for errors being logged by the
|
|
nsx-appl-proxy subcomponent within /var/log/syslog.
|
|
"
|
|
::= { vmwNsxTFederationFeature 3 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 4 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
|
|
state between the remote locations. If a remote location is connected but not synchronized,
|
|
it is possible that the location is still in the process of master resolution. In
|
|
this case, wait for around 10 seconds and try invoking the CLI again to
|
|
check for the state of the remote location. If a location is disconnected, try the next
|
|
step.
|
|
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
|
|
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
|
|
check for flakiness in WAN connectivity. If there are no physical network
|
|
connectivity issues, try the next step.
|
|
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
|
|
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
|
|
communication errors. In addition, also look for errors being logged by the
|
|
nsx-appl-proxy subcomponent within /var/log/syslog.
|
|
"
|
|
::= { vmwNsxTFederationFeature 5 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote locations vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 6 }
|
|
|
|
vmwNsxTFederationQueueOccupancyThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
has reached size vmwNsxTDataCenterQueueSize which is at or above the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
|
|
|
|
Action required:
|
|
Queue size can exceed threshold due to communication issue with remote site or an overloaded system.
|
|
Please check system performance and /var/log/async-replicator/ar.log to see if there are any errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 29 }
|
|
|
|
vmwNsxTFederationQueueOccupancyThresholdExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
has reached size vmwNsxTDataCenterQueueSize which is below the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 30 }
|
|
|
|
vmwNsxTFederationRtepBGPDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
|
|
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is down.
|
|
Reason: vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node.
|
|
2. Switch to REMOTE_TUNNEL_VRF context.
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
|
|
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
|
|
to get the BGP neighbor status.
|
|
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
|
|
to the interface with name remote-tunnel-endpoint.
|
|
6. Check if the ping is working successfully between assigned RTEP IP address (vmwNsxTDataCenterBGPSourceIP) and the
|
|
remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP.
|
|
7. Check /var/log/syslog for any errors related to BGP.
|
|
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
|
|
configuration on the edge node.
|
|
This will update the RTEP IP assigned to the affected edge node.
|
|
|
|
If the reason indicates `Edge is not ready`, check why edge is not in good state.
|
|
1. Invoke the NSX CLI command `get edge-cluster status` to check reason why edge might be down.
|
|
2. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
3. Check any edge health related alarms to get more information.
|
|
"
|
|
::= { vmwNsxTFederationFeature 1 }
|
|
|
|
vmwNsxTFederationRtepBGPDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterBGPNeighborIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
|
|
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is established.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 2 }
|
|
|
|
vmwNsxTFederationRtepConnectivityLost NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterRemoteSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterTransportNodeName lost RTEP (Remote Tunnel Endpoint) connectivity
|
|
with remote location vmwNsxTDataCenterRemoteSiteName.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node vmwNsxTDataCenterTransportNodeName.
|
|
2. Switch to REMOTE_TUNNEL_VRF context.
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
|
|
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
|
|
to get the BGP neighbor status.
|
|
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
|
|
to the interface with name remote-tunnel-endpoint.
|
|
6. Check if the ping is working successfully between assigned RTEP IP address and the RTEP IP addresses
|
|
on the remote location vmwNsxTDataCenterRemoteSiteName.
|
|
7. Check /var/log/syslog for any errors related to BGP.
|
|
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
|
|
configuration on the edge node.
|
|
This will update the RTEP IP assigned to the affected edge node vmwNsxTDataCenterTransportNodeName.
|
|
"
|
|
::= { vmwNsxTFederationFeature 7 }
|
|
|
|
vmwNsxTFederationRtepConnectivityLostClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterRemoteSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterTransportNodeName has restored RTEP (Remote Tunnel Endpoint) connectivity
|
|
with remote location vmwNsxTDataCenterRemoteSiteName.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- GatewayFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTGatewayFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the GatewayFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 39 }
|
|
|
|
vmwNsxTGatewayFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for GatewayFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for ICMP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 21 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 22 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for ICMP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 23 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 24 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for IP traffic on logical router vmwNsxTDataCenterEntityId has
|
|
reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for IP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 25 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 26 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for IP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for IP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 27 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for non IP flows on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 28 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP half-open traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for TCP half-open flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 29 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 30 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for TCP half-open flow.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 31 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP half-open on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 32 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for UDP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 33 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 34 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for UDP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 35 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 36 }
|
|
|
|
-- **********************************************************
|
|
-- HighAvailability feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTHighAvailabilityFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the HighAvailability feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 21 }
|
|
|
|
vmwNsxTHighAvailabilityFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for HighAvailability feature notifications.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeaturePrefix 0 }
|
|
|
|
vmwNsxTHighAvailabilityTier0GatewayFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterServiceRouterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier0 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
|
|
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id>` to
|
|
identify the tier0 service-router vrf ID. Switch to the vrf context by
|
|
invoking `vrf <vrf-id>` then invoke `get high-availability status`
|
|
to determine the service that is down.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 9 }
|
|
|
|
vmwNsxTHighAvailabilityTier0GatewayFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier0 gateway vmwNsxTDataCenterEntityId is now up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 10 }
|
|
|
|
vmwNsxTHighAvailabilityTier1GatewayFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterServiceRouterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier1 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
|
|
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id>` to
|
|
identify the tier1 service-router vrf ID. Switch to the vrf context by
|
|
invoking `vrf <vrf-id>` then invoke `get high-availability status`
|
|
to determine the service that is down.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 11 }
|
|
|
|
vmwNsxTHighAvailabilityTier1GatewayFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier1 gateway vmwNsxTDataCenterEntityId is now up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 12 }
|
|
|
|
-- **********************************************************
|
|
-- IdentityFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIdentityFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IdentityFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 36 }
|
|
|
|
vmwNsxTIdentityFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IdentityFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLDAPServer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost.
|
|
|
|
Action required:
|
|
Please check
|
|
1. The LDAP server is reachable from NSX nodes.
|
|
2. The LDAP server details are configured correctly in NSX.
|
|
3. The LDAP server is running correctly.
|
|
4. There are no firewalls blocking access between the LDAP server
|
|
and NSX nodes.
|
|
Afer the issue is fixed, use TEST CONNECTION in NSX UI under
|
|
Identity Firewall AD to test the connection.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 1 }
|
|
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLDAPServer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 2 }
|
|
|
|
vmwNsxTIdentityFirewallErrorInDeltaSync NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDirectoryDomain
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
|
|
|
|
Action required:
|
|
1. Check if there are any connectivity to LDAP server lost alarms.
|
|
2. Find the error details in /var/log/syslog. Around the alarm trigger
|
|
time, search for text: Error happened when synchronize LDAP objects.
|
|
3. Check with AD administrator if there are any recent AD changes which
|
|
may cause the errors.
|
|
4. If the errors persist, collect the technical support bundle and
|
|
contact VMware technical support.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 3 }
|
|
|
|
vmwNsxTIdentityFirewallErrorInDeltaSyncClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDirectoryDomain
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- InfrastructureCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTInfrastructureCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the InfrastructureCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 7 }
|
|
|
|
vmwNsxTInfrastructureCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for InfrastructureCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The overall tunnel status of Edge node vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get tunnel-ports` to get all tunnel ports,
|
|
then check each tunnel's stats by invoking NSX CLI command
|
|
`get tunnel-port <UUID> stats` to check if there are any drops. Also
|
|
check /var/log/syslog if there are tunnel related errors.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeature 17 }
|
|
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tunnels of Edge node vmwNsxTDataCenterEntityId have been restored.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeature 18 }
|
|
|
|
-- **********************************************************
|
|
-- InfrastructureService feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTInfrastructureServiceFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the InfrastructureService feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 19 }
|
|
|
|
vmwNsxTInfrastructureServiceFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for InfrastructureService feature notifications.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeaturePrefix 0 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterCurrentServiceState,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
|
|
to vmwNsxTDataCenterCurrentServiceState.
|
|
vmwNsxTDataCenterServiceDownReason
|
|
|
|
Action required:
|
|
On the Edge node, verify the service hasn't exited due to an error by
|
|
looking for core files in the /var/log/core directory. In addition,
|
|
invoke the NSX CLI command `get services` to confirm whether the service
|
|
is stopped. If so, invoke `start service <service-name>` to restart the
|
|
service.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 1 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterCurrentServiceState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
|
|
to vmwNsxTDataCenterCurrentServiceState.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 2 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName is down for at least one minute.
|
|
vmwNsxTDataCenterServiceDownReason
|
|
|
|
Action required:
|
|
On the Edge node, verify the service hasn't exited due to an error by
|
|
looking for core files in the /var/log/core directory. In addition,
|
|
invoke the NSX CLI command `get services` to confirm whether the service
|
|
is stopped. If so, invoke `start service <service-name>` to restart the
|
|
service.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 3 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 4 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName has been unresponsive for 10 seconds.
|
|
|
|
Action required:
|
|
Verify vmwNsxTDataCenterServiceName service is still running by invoking `/etc/init.d/vmwNsxTDataCenterServiceName status`.
|
|
If the service is reported as running, it may need to get restarted which can be done by
|
|
`/etc/init.d/vmwNsxTDataCenterServiceName restart`. Rerun the status command to verify the service is now
|
|
running. If the script `/etc/init.d/vmwNsxTDataCenterServiceName` is unavailable, please try invoking
|
|
`systemctl vmwNsxTDataCenterServiceName status` and restart by `systemctl vmwNsxTDataCenterServiceName restart` with root
|
|
priviledges. If restarting the service does not resolve the issue or if the issue reoccurs after
|
|
a successful restart, please contact VMware Support.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 7 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName is responsive again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- IntelligenceCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIntelligenceCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IntelligenceCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 9 }
|
|
|
|
vmwNsxTIntelligenceCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IntelligenceCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
|
|
the Intelligence node's messaging broker. Data collection is affected.
|
|
|
|
Action required:
|
|
Restart the messaging service if it is not running in the Intelligence
|
|
node. Resolve the network connection failure between the Transport node
|
|
flow exporter and the Intelligence node.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeature 7 }
|
|
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
|
|
the Intelligence node's messaging broker.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- IntelligenceHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIntelligenceHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IntelligenceHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 6 }
|
|
|
|
vmwNsxTIntelligenceHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IntelligenceHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most CPU usages, and
|
|
then check /var/log/syslog and these processes' local logs to see if there
|
|
are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 41 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 42 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most CPU usages, and
|
|
then check /var/log/syslog and these processes' local logs to see if there
|
|
are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 43 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 44 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Stop NSX intelligence data collection until the disk usage is below
|
|
the threshold. Examine disk partition /data and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 45 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 46 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Stop NSX intelligence data collection until the disk usage is below
|
|
the threshold. In the NSX UI, navigate to System | Appliances | NSX
|
|
Intelligence Appliance. Then click ACTONS, Stop Collecting Data.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 47 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 48 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 49 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 50 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 51 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 52 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most memory usages,
|
|
and then check /var/log/syslog and these processes' local logs to see if
|
|
there are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 53 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 54 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most memory usages,
|
|
and then check /var/log/syslog and these processes' local logs to see if
|
|
there are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 55 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 56 }
|
|
|
|
vmwNsxTIntelligenceHealthNodeStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterIntelligenceNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is degraded.
|
|
|
|
Action required:
|
|
Invoke the NSX API GET /napp/api/v1/platform/monitor/category/health to
|
|
check which specific pod is down and the reason behind it. Invoke the following
|
|
CLI command to restart the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 57 }
|
|
|
|
vmwNsxTIntelligenceHealthNodeStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterIntelligenceNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 58 }
|
|
|
|
vmwNsxTIntelligenceHealthStorageLatencyHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
|
|
|
|
Action required:
|
|
Transient high storage latency may happen due to spike of I/O requests.
|
|
If storage latency remains high for more than 30 minutes,
|
|
consider deploying NSX Intelligence appliance in a low latency disk,
|
|
or not sharing the same storage device with other VMs.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 63 }
|
|
|
|
vmwNsxTIntelligenceHealthStorageLatencyHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 64 }
|
|
|
|
-- **********************************************************
|
|
-- IPAM feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIPAMFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IPAM feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 38 }
|
|
|
|
vmwNsxTIPAMFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IPAM feature notifications.
|
|
"
|
|
::= { vmwNsxTIPAMFeaturePrefix 0 }
|
|
|
|
vmwNsxTIPAMIPBlockUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP block usage of vmwNsxTDataCenterIntentPath is very high.
|
|
IP block nearing its total capacity, creation of subnet using IP block might fail.
|
|
|
|
Action required:
|
|
Please review IP block usage. Use new IP block for resource creation or delete unused IP subnet from the IP block.
|
|
To check subnet being used for IP Block. From NSX UI, navigate to Networking | IP Address pools | IP Address pools tab.
|
|
Select IP pools where IP block being used, check Subnets and Allocated IPs column on UI. If no allocation has been used for the IP pool and it is not going to be used in future then delete subnet or IP pool.
|
|
Use following API to check if IP block being used by IP pool and also check if any IP allocation done:
|
|
To get configured subnets of an IP pool, invoke the NSX API
|
|
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-subnets
|
|
To get IP allocations, invoke the NSX API
|
|
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations
|
|
Please note: Deletion of IP pool/subnet should only be done if it does not have any allocated IPs and it is not going to be used in future.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 1 }
|
|
|
|
vmwNsxTIPAMIPBlockUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP block usage of vmwNsxTDataCenterIntentPath is below threshold level.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 2 }
|
|
|
|
vmwNsxTIPAMIPPoolUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP pool usage of vmwNsxTDataCenterIntentPath is very high.
|
|
IP pool nearing its total capacity. Creation of entity/service depends on IP being allocated from IP pool might fail.
|
|
|
|
Action required:
|
|
Please review IP pool usage.
|
|
Release unused ip allocations from IP pool or create new IP pool and use it.
|
|
From NSX UI navigate to Networking | IP Address pools | IP Address pools tab.
|
|
Select IP pools and check Allocated IPs column, this will show IPs allocated from the IP pool.
|
|
If user see any IPs are not being used then those IPs can be released.
|
|
To release unused IP allocations, invoke the NSX API
|
|
DELETE /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations/<ip-allocation>
|
|
"
|
|
::= { vmwNsxTIPAMFeature 3 }
|
|
|
|
vmwNsxTIPAMIPPoolUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP pool usage of vmwNsxTDataCenterIntentPath is normal now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Licenses feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTLicensesFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Licenses feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 5 }
|
|
|
|
vmwNsxTLicensesFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Licenses feature notifications.
|
|
"
|
|
::= { vmwNsxTLicensesFeaturePrefix 0 }
|
|
|
|
vmwNsxTLicensesLicenseExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has expired.
|
|
|
|
Action required:
|
|
Add a new, non-expired license using the NSX UI by navigating to
|
|
System | Licenses then click ADD and specify the key of the new
|
|
license. The expired license should be deleted by checking the
|
|
checkbox of the license, then click DELETE.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 1 }
|
|
|
|
vmwNsxTLicensesLicenseExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expired vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
|
|
longer about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 2 }
|
|
|
|
vmwNsxTLicensesLicenseIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, is about to expire.
|
|
|
|
Action required:
|
|
The license is about to expire in several days. Please plan to add a
|
|
new, non-expiring license using the NSX UI by navigating to System |
|
|
Licenses then click ADD and specify the key of the new license. The
|
|
expired license should be deleted by checking the checkbox of the
|
|
license, then click DELETE.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 3 }
|
|
|
|
vmwNsxTLicensesLicenseIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
|
|
longer about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- LoadBalancer feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTLoadBalancerFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the LoadBalancer feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 17 }
|
|
|
|
vmwNsxTLoadBalancerFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for LoadBalancer feature notifications.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeaturePrefix 0 }
|
|
|
|
vmwNsxTLoadBalancerDLBStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed load balancer service vmwNsxTDataCenterEntityId is down.
|
|
|
|
This notification is sent once when the down state is first detected.
|
|
|
|
Action required:
|
|
On ESXi host node, invoke the NSX CLI command `get load-balancer
|
|
<lb-uuid> status`.
|
|
If 'Conflict LSP' is reported, please check whether this LSP is attached
|
|
to other load balancer service. Please check whether this conflict is
|
|
acceptable.
|
|
If 'Not Ready LSP' is reported, please check the status of this LSP by
|
|
invoking NSX CLI command `get logical-switch-port status`.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 17 }
|
|
|
|
vmwNsxTLoadBalancerDLBStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed load balancer service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 18 }
|
|
|
|
vmwNsxTLoadBalancerLBCPUVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of load balancer vmwNsxTDataCenterEntityId is vmwNsxTDataCenterSystemResourceUsage%
|
|
which is higher than the very high threshold of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
If the load balancer CPU utilization is higher than vmwNsxTDataCenterSystemUsageThreshold%,
|
|
the workload is too high for this load balancer. Rescale the load balancer
|
|
service by changing the load balancer size from small to medium or from
|
|
medium to large. If the CPU utilization of this load balancer is still high,
|
|
consider adjusting the Edge appliance form factor size or moving load
|
|
balancer services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 1 }
|
|
|
|
vmwNsxTLoadBalancerLBCPUVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU utilization of load balancer vmwNsxTDataCenterEntityId is vmwNsxTDataCenterSystemResourceUsage%
|
|
which is lower than the very high threshold of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 2 }
|
|
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
This notification is sent once when the high usage state is first detected.
|
|
|
|
Action required:
|
|
If multiple LB instances have been configurerd in this Edge node, deploy a
|
|
new Edge node and move some LB instances to that new Edge node. If only a
|
|
single LB instance (small/medium/etc) has been configured in an Edge node of
|
|
same size (small/medium/etc), deploy a new Edge of bigger size and move the
|
|
LB instance to that new Edge node.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 3 }
|
|
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is below
|
|
the threshold of vmwNsxTDataCenterSystemUsageThreshold% for a sufficient number
|
|
of samples over 2 minutes.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 4 }
|
|
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
This notification is sent once when the high usage state is first detected.
|
|
|
|
Action required:
|
|
Deploy a new Edge node and move the load balancer service from existing Edge
|
|
nodes to the newly deployed Edge node.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 5 }
|
|
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is below
|
|
the threshold of vmwNsxTDataCenterSystemUsageThreshold% for a sufficient number
|
|
of samples over 2 minutes.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 6 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer service vmwNsxTDataCenterEntityId is degraded.
|
|
|
|
This notification is sent once when the degraded state is first detected.
|
|
|
|
Action required:
|
|
For centralized load balancer:
|
|
On standby Edge node, check load balancer status by invoking the NSX CLI
|
|
command `get load-balancer <lb-uuid> status`. If the LB-State of load
|
|
balancer service is not_ready or there is no output, make the Edge node
|
|
enter maintenance mode, then exit maintenance mode.
|
|
For distributed load balancer:
|
|
1. Get detailed status by invoking NSX-T API GET
|
|
/policy/api/v1/infra/lb-services/<LBService>/detailed-status?source=realtime
|
|
2. From API output, find ESXi host reporting a non-zero instance_number
|
|
with status NOT_READY or CONFLICT.
|
|
3. On ESXi host node, invoke the NSX CLI command `get load-balancer
|
|
<lb-uuid> status`.
|
|
If 'Conflict LSP'is reported, please check whether this LSP is attached
|
|
to other load balancer service. Please check whether this conflict is
|
|
acceptable.
|
|
If 'Not Ready LSP' is reported, please check the status of this LSP by
|
|
invoking NSX CLI command `get logical-switch-port status`.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 15 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer service vmwNsxTDataCenterEntityId is not degraded.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 16 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer service vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Verify whether the load balancer service in the Edge node is running.
|
|
If the status of load balancer service is not ready, make the Edge
|
|
node enter maintenance mode, then exit maintenance mode. If the status
|
|
of load balancer is still not recovered, please check whether there
|
|
are any error log in /var/log/syslog.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 7 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The noad balancer service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 8 }
|
|
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer configuration vmwNsxTDataCenterEntityId is not realized,
|
|
due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
Prefer defining small and medium sized load balancers over large sized load balancers.
|
|
Spread out load balancer services among the available Edge nodes.
|
|
Reduce number of Virtual Servers defined.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 19 }
|
|
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 20 }
|
|
|
|
vmwNsxTLoadBalancerPoolStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer pool vmwNsxTDataCenterEntityId status is down.
|
|
|
|
Action required:
|
|
Consult the load balancer pool to determine which members are down by
|
|
invoking the NSX CLI command
|
|
`get load-balancer <lb-uuid> pool <pool-uuid> status`
|
|
or NSX API GET
|
|
/policy/api/v1/infra/lb-services/<lb-service-id>/lb-pools/<lb-pool-id>/detailed-status
|
|
If DOWN or UNKNOWN is reported, please verify the pool member.
|
|
Check network connectivity from the load balancer to the impacted pool members.
|
|
Validate application health of each pool member. Also validate the health
|
|
of each pool member using the configured monitor. When the health of the
|
|
member is established, the pool member status is updated to healthy based
|
|
on the 'Rise Count' configuration in the monitor.
|
|
Remediate the issue by rebooting the pool member or make the Edge node
|
|
enter maintenance mode, then exit maintenance mode.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 9 }
|
|
|
|
vmwNsxTLoadBalancerPoolStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer pool vmwNsxTDataCenterEntityId status is up
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 10 }
|
|
|
|
vmwNsxTLoadBalancerVirtualServerStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer virtual server vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Consult the load balancer pool to determine its status and verify its
|
|
configuration. If incorrectly configured, reconfigure it and remove the
|
|
load balancer pool from the virtual server then re-add it to the
|
|
virtual server again.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 11 }
|
|
|
|
vmwNsxTLoadBalancerVirtualServerStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer virtual server vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 12 }
|
|
|
|
-- **********************************************************
|
|
-- ManagerHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTManagerHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the ManagerHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 1 }
|
|
|
|
vmwNsxTManagerHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for ManagerHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTManagerHealthDuplicateIPAddress NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDuplicateIPAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager node vmwNsxTDataCenterEntityId IP address vmwNsxTDataCenterDuplicateIPAddress is
|
|
currently being used by another device in the network.
|
|
|
|
Action required:
|
|
1. Determine which device is using the Manager's IP address
|
|
and assign the device a new IP address. Note, reconfiguring
|
|
the Manager to use a new IP address is not supported.
|
|
2. Ensure the static IP address pool/DHCP server is configured correctly.
|
|
3. Correct the IP address of the device if it is manually assigned.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 17 }
|
|
|
|
vmwNsxTManagerHealthDuplicateIPAddressClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDuplicateIPAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device using the IP address assigned to Manager node
|
|
vmwNsxTDataCenterEntityId appears to no longer be using vmwNsxTDataCenterDuplicateIPAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 18 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
|
|
usage by the NSX Datastore service under the /config/corfu directory.
|
|
|
|
Action required:
|
|
Please run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 13 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 14 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
|
|
by the NSX Datastore service under the /config/corfu directory.
|
|
|
|
Action required:
|
|
Please run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 15 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 16 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this
|
|
Manager node. Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 1 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 2 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this
|
|
Manager node. Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 3 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 4 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 9 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 10 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 11 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 12 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this
|
|
Manager node. Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 5 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 6 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Please review the configuration, running services and sizing of this
|
|
Manager node. Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 7 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 8 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
|
|
usage by the NSX Datastore service under the /nonconfig/corfu directory.
|
|
|
|
Action required:
|
|
Please run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 19 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 20 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
|
|
by the NSX Datastore service under the /nonconfig/corfu directory.
|
|
|
|
Action required:
|
|
Please run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 21 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 22 }
|
|
|
|
vmwNsxTManagerHealthStorageError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId is in
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
Examine the read-only partition to see if reboot resolves the issue
|
|
or the disk needs to be replaced. Contact GSS for more information.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 23 }
|
|
|
|
vmwNsxTManagerHealthStorageErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId
|
|
has recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 24 }
|
|
|
|
-- **********************************************************
|
|
-- MTUCheck feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTMTUCheckFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the MTUCheck feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 42 }
|
|
|
|
vmwNsxTMTUCheckFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for MTUCheck feature notifications.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeaturePrefix 0 }
|
|
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBig NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The global router MTU configuration is bigger than MTU of switches in overlay Transport Zone which connects
|
|
to Tier0 or Tier1. Global router MTU value should be less than all switches MTU value by at least
|
|
a 100 as we require 100 quota for Geneve encapsulation.
|
|
|
|
Action required:
|
|
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
|
|
more mismatch details.
|
|
2. Set the bigger MTU value on switches by invoking the NSX API
|
|
PUT /api/v1/host-switch-profiles/<host-switch-profile-id> with mtu in the
|
|
request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
|
|
with physical_uplink_mtu in request body.
|
|
3. Or set the smaller MTU value of global router configuration by invoking the NSX API PUT
|
|
/api/v1/global-configs/RoutingGlobalConfig with logical_uplink_mtu in the request body.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 3 }
|
|
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The global router MTU is less than the MTU of overlay Transport Zone now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 4 }
|
|
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZone NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTU configuration mismatch between Transport Nodes (ESXi, KVM and Edge) attached to the same Transport Zone.
|
|
MTU values on all switches attached to the same Transport Zone not being consistent will cause
|
|
connectivity issues.
|
|
|
|
Action required:
|
|
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
|
|
more mismatch details.
|
|
2. Set the same MTU value on all switches attached to the same Transport Zone
|
|
by invoking the NSX API PUT /api/v1/host-switch-profiles/<host-switch-profile-id>
|
|
with mtu in the request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
|
|
with physical_uplink_mtu in request body.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 1 }
|
|
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All MTU values between Transport Nodes attached to the same Transport Zone are consistent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- NAT feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNATFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NAT feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 46 }
|
|
|
|
vmwNsxTNATFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NAT feature notifications.
|
|
"
|
|
::= { vmwNsxTNATFeaturePrefix 0 }
|
|
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for
|
|
SNAT IP vmwNsxTDataCenterSNATIPAddress has reached
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will
|
|
not be SNATed when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> connection state` by using the right interface
|
|
uuid and check various SNAT mappings for the SNAT IP vmwNsxTDataCenterSNATIPAddress.
|
|
Check traffic flows going through the gateway is not a denial-of-service
|
|
attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider adding more
|
|
SNAT IP addresses to distribute the load or
|
|
route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTNATFeature 1 }
|
|
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress
|
|
has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNATFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- NCPHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNCPHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NCPHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 11 }
|
|
|
|
vmwNsxTNCPHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NCPHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNCPHealthNCPPluginDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager Node has detected the NCP is down or unhealthy.
|
|
|
|
Action required:
|
|
To find the clusters which are having issues, please use the
|
|
NSX UI and navigate to the Alarms page. The Entity name value for
|
|
this alarm instance identifies the cluster name. Or invoke the
|
|
NSX API GET /api/v1/systemhealth/container-cluster/ncp/status
|
|
to fetch all cluster statuses and determine the name of any clusters
|
|
that report DOWN or UNKNOWN. Then on the NSX UI
|
|
Inventory | Container | Clusters page find the cluster by name and
|
|
click the Nodes tab which lists all Kubernetes and PAS cluster members.
|
|
For Kubernetes cluster:
|
|
1. Check NCP Pod liveness by finding the K8s master node from all the
|
|
cluster members and log onto the master node. Then invoke the kubectl
|
|
command `kubectl get pods --all-namespaces`. If there is an issue with
|
|
the NCP Pod, please use kubectl logs command to check the issue and fix
|
|
the error.
|
|
2. Check the connection between NCP and Kubernetes API server. The
|
|
NSX CLI can be used inside the NCP Pod to check this connection status
|
|
by invoking the following commands from the master VM.
|
|
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
|
|
`nsxcli`
|
|
`get ncp-k8s-api-server status`
|
|
If there is an issue with the connection, please check both the network
|
|
and NCP configurations.
|
|
3. Check the connection between NCP and NSX Manager. The NSX CLI can be
|
|
used inside the NCP Pod to check this connection status by invoking the
|
|
following command from the master VM.
|
|
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
|
|
`nsxcli`
|
|
`get ncp-nsx status`
|
|
If there is an issue with the connection, please check both the network
|
|
and NCP configurations.
|
|
For PAS cluster:
|
|
1. Check the network connections between virtual machines and fix any
|
|
network issues.
|
|
2. Check the status of both nodes and services and fix crashed nodes
|
|
or services. Invoke the command `bosh vms` and `bosh instances -p` to
|
|
check the status of nodes and services.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeature 3 }
|
|
|
|
vmwNsxTNCPHealthNCPPluginDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager Node has detected the NCP is up or healthy again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- NodeAgentsHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNodeAgentsHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NodeAgentsHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 12 }
|
|
|
|
vmwNsxTNodeAgentsHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NodeAgentsHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents running inside the Node VM appear to be down.
|
|
|
|
Action required:
|
|
For ESX:
|
|
1. If Vmk50 is missing, refer to this Knowledge Base article
|
|
https://kb.vmware.com/s/article/67432.
|
|
2. If Hyperbus 4094 is missing, restarting nsx-cfgagent or restarting the
|
|
container host VM may help.
|
|
3. If container host VIF is blocked, check the connection to the Controller
|
|
to make sure all configurations are sent down.
|
|
4. If nsx-cfg-agent has stopped, restart nsx-cfgagent.
|
|
For KVM:
|
|
1. If Hyperbus namespace is missing, restarting the nsx-opsagent may help
|
|
recreate the namespace.
|
|
2. If Hyperbus interface is missing inside the hyperbus namespace,
|
|
restarting the nsx-opsagent may help.
|
|
3. If nsx-agent has stopped, restart nsx-agent.
|
|
For Both ESX and KVM:
|
|
1. If the node-agent package is missing, check whether node-agent package
|
|
has been successfully installed in the container host vm.
|
|
2. If the interface for node-agent in container host vm is down, check the
|
|
eth1 interface status inside the container host vm.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 3 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents inside the Node VM are running.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- NSXApplicationPlatformCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NSXApplicationPlatformCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 41 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NSXApplicationPlatformCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Over Flow is above the
|
|
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
Add nodes and then scale up the NSX Application Platform cluster. If bottleneck can be attributed to a specific service,
|
|
for example, the analytics service, then scale up the specific service when the new nodes are added.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 7 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Over Flow is below the pending
|
|
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 8 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Raw Flow is above the
|
|
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
Add nodes and then scale up the NSX Application Platform cluster. If the bottleneck can be attributed to a specific service,
|
|
for example, the analytics service, then scale up the specific service when the new nodes are added.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 11 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Raw Flow is below the pending
|
|
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 12 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is disconnected
|
|
from the NSX management cluster.
|
|
|
|
Action required:
|
|
Check whether the manager cluster certificate, manager node certificates,
|
|
kafka certificate and ingress certificate match on both NSX Manager and the
|
|
NSX Application Platform cluster. Check expiration dates of the above mentioned
|
|
certificates to make sure they are valid. Check the network connection between
|
|
NSX Manager and NSX Application Platform cluster and resolve any network connection failures.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 1 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is reconnected
|
|
to the NSX management cluster.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 2 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
|
|
the NSX Application Platform cluster's messaging broker. Data collection is affected.
|
|
|
|
Action required:
|
|
Restart the messaging service if it is not running in the NSX Application
|
|
Platform cluster. Resolve the network connection failure between the Transport node
|
|
flow exporter and the NSX Application Platform cluster.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 13 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
|
|
the NSX Application Platform cluster's messaging broker.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 14 }
|
|
|
|
-- **********************************************************
|
|
-- NSXApplicationPlatformHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NSXApplicationPlatformHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 43 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NSXApplicationPlatformHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 1 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 2 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 3 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 4 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 5 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 6 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 7 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 8 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 9 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 10 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 11 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 12 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
computing power is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 13 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 14 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
computing power is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 15 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 16 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
disk storage is required, click on the Scale Out button to request more resources.
|
|
If data storage service is under strain, another way is to click on the Scale Up button
|
|
to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 17 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 18 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
disk storage is required, click on the Scale Out button to request more resources.
|
|
If data storage service is under strain, another way is to click on the Scale Up button
|
|
to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 19 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 20 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
memory is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 21 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 22 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
memory is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 23 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 24 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 31 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 32 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 33 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 34 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 35 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 36 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 37 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 38 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 109 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 110 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 39 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 40 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 41 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 42 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 43 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 44 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out or scale up the data storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 45 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 46 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out or scale up the data storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 47 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 48 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 49 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 50 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 51 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 52 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 53 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 54 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 55 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 56 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 57 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 58 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 59 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 60 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 61 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 62 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 63 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 64 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 97 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 98 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 99 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 100 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 101 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 102 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 103 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 104 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 105 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 106 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 107 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 108 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is degraded.
|
|
|
|
Action required:
|
|
Get more information from alarms of nodes and services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 117 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 118 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is down.
|
|
|
|
Action required:
|
|
Get more information from alarms of nodes and services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 119 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 120 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 65 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 66 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 67 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 68 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see which service is
|
|
under pressure. Clean up unused data or log to free up disk resources
|
|
and see if the load can be reduced. If more disk storage is required, Scale Out the
|
|
service under pressure. If data storage service is under strain, another way is to
|
|
click on the Scale Up button to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 69 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 70 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. Clean up unused data or log to free up disk resources
|
|
and see if the load can be reduced. If more disk storage is required, Scale Out the
|
|
service under pressure. If data storage service is under strain, another way is to
|
|
click on the Scale Up button to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 71 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 72 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 73 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 74 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 75 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 76 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is degraded.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Resources to
|
|
check which node is degraded. Check network, memory and CPU usage of the node.
|
|
Reboot the node if it is a worker node.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 77 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 78 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is not running.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Resources to
|
|
check which node is down. Check network, memory and CPU usage of the node.
|
|
Reboot the node if it is a worker node.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 79 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 80 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 81 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 82 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 83 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 84 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 85 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 86 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 87 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 88 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 89 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 90 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 91 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 92 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is degraded. The service may still be able to reach a quorum while
|
|
pods associated with vmwNsxTDataCenterNappServiceName are not all stable. Resources consumed by these
|
|
unstable pods may be released.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
|
|
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
|
|
specific service is degraded and the reason behind it. Invoke the following CLI command to restart
|
|
the degraded service if necessary:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
Degraded services can function correctly but performance is sub-optimal.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 93 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 94 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is not running.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
|
|
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
|
|
specific service is down and the reason behind it. Invoke the following CLI command to restart
|
|
the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 95 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 96 }
|
|
|
|
-- **********************************************************
|
|
-- PasswordManagement feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTPasswordManagementFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the PasswordManagement feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 4 }
|
|
|
|
vmwNsxTPasswordManagementFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for PasswordManagement feature notifications.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeaturePrefix 0 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpirationApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername,
|
|
vmwNsxTDataCenterPasswordExpirationDays
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername is approaching expiration in
|
|
vmwNsxTDataCenterPasswordExpirationDays days.
|
|
|
|
Action required:
|
|
The password for the user vmwNsxTDataCenterUsername needs to be changed soon. For example,
|
|
to apply a new password to a user, invoke the following NSX API with a valid
|
|
password in the request body: PUT /api/v1/node/users/<userid> where <userid>
|
|
is the ID of the user.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 1 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpirationApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 2 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername has expired.
|
|
|
|
Action required:
|
|
The password for user vmwNsxTDataCenterUsername must be changed now to access the
|
|
system. For example, to apply a new password to a user, invoke the
|
|
following NSX API with a valid password in the request body: PUT
|
|
/api/v1/node/users/<userid> where <userid> is the ID of the user. If the
|
|
admin user (with <userid> 10000) password has expired, admin must login to
|
|
the system via SSH (if enabled) or console in order to change the password.
|
|
Upon entering the current expired password, admin will be prompted to enter
|
|
a new password.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 3 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 4 }
|
|
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername,
|
|
vmwNsxTDataCenterPasswordExpirationDays
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername is about to expire in
|
|
vmwNsxTDataCenterPasswordExpirationDays days.
|
|
|
|
Action required:
|
|
Ensure the password for the user vmwNsxTDataCenterUsername is changed immediately. For
|
|
example, to apply a new password to a user, invoke the following NSX API
|
|
with a valid password in the request body: PUT /api/v1/node/users/<userid>
|
|
where <userid> is the ID of the user.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 5 }
|
|
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Routing feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTRoutingFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Routing feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 28 }
|
|
|
|
vmwNsxTRoutingFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Routing feature notifications.
|
|
"
|
|
::= { vmwNsxTRoutingFeaturePrefix 0 }
|
|
|
|
vmwNsxTRoutingBFDDownOnExternalInterface NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterPeerAddress,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is down.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to the service router vmwNsxTDataCenterSrId
|
|
3. Invoke the NSX CLI command `ping vmwNsxTDataCenterPeerAddress` to verify the
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 7 }
|
|
|
|
vmwNsxTRoutingBFDDownOnExternalInterfaceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 8 }
|
|
|
|
vmwNsxTRoutingBGPDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterFailureReason,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down.
|
|
Reason: vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to service-router vmwNsxTDataCenterSrId.
|
|
If the reason indicates Network or config error -
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the
|
|
BGP neighbor status.
|
|
If the reason indicates `Edge is not ready`, check why edge is not in good state.
|
|
4. Invoke the NSX CLI command `get edge-cluster status` to check reason why edge might be down.
|
|
5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
6. Check any edge health related alarms to get more information.
|
|
Check /var/log/syslog to see if there are any errors related to BGP
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 1 }
|
|
|
|
vmwNsxTRoutingBGPDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterBGPNeighborIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 2 }
|
|
|
|
vmwNsxTRoutingOSPFNeighborWentDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved from full to another state.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` to get the vrf id and
|
|
switch to TIER0 service router.
|
|
2. Run `get ospf neighbor` to check the current state of this neighbor. If the
|
|
neighbor is not listed in the output, the neighbor has gone down or out of
|
|
the network.
|
|
3. Invoke the NSX CLI command `ping <OSPF neighbor IP address>` to verify the
|
|
connectivity.
|
|
4. Also, verify the configuration for both NSX and peer router to ensure that
|
|
timers and area-id match.
|
|
5. Check /var/log/syslog to see if there are any errors related to connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 11 }
|
|
|
|
vmwNsxTRoutingOSPFNeighborWentDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved to full state.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 12 }
|
|
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceIP,
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterLrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Proxy arp for Service IP vmwNsxTDataCenterServiceIP and Service entity vmwNsxTDataCenterEntityId
|
|
is not configured as the number of arp proxy entries generated due to overlap of
|
|
the Service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId has exceeded
|
|
the allowed threshold limit of 16384.
|
|
|
|
This notification is sent once when the threshold limit is exceeded.
|
|
|
|
Action required:
|
|
Reconfigure the Service IP vmwNsxTDataCenterServiceIP for the Service entity vmwNsxTDataCenterEntityId
|
|
or change the subnet of the lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId so that the proxy arp entries
|
|
generated due to the overlap between the Service IP and the subnet of lrport is less than
|
|
the allowed threshold limit of 16384.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 13 }
|
|
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterLrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Proxy arp for Service entity vmwNsxTDataCenterEntityId is generated successfully as the
|
|
overlap of service Ip with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId is
|
|
within the allowed limit of 16384 entries.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 14 }
|
|
|
|
vmwNsxTRoutingRoutingDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All BGP/BFD sessions are down.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-routers` to get the tier0 service router
|
|
and switch to this vrf, then invoke the following NSX CLI commands.
|
|
1. `ping <BFD peer IP address>` to verify connectivity.
|
|
2. `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
3. `get bgp neighbor summary` to check if BGP is running well.
|
|
Also check /var/log/syslog to see if there are any errors related to BGP
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 9 }
|
|
|
|
vmwNsxTRoutingRoutingDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At least one BGP/BFD session up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 10 }
|
|
|
|
vmwNsxTRoutingStaticRoutingRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterStaticAddress,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was removed because
|
|
BFD was down.
|
|
|
|
Action required:
|
|
The static routing entry was removed because the BFD session was down.
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to the service-router vmwNsxTDataCenterSrId.
|
|
3. Invoke the NSX CLI command `ping <BFD peer IP address>` to verify the
|
|
connectivity.
|
|
Also, verify the configuration in both NSX and the BFD peer to ensure that
|
|
timers have not been changed.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 5 }
|
|
|
|
vmwNsxTRoutingStaticRoutingRemovedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterStaticAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was re-added as BFD
|
|
recovered.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- TransportNodeHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTTransportNodeHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the TransportNodeHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 18 }
|
|
|
|
vmwNsxTTransportNodeHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for TransportNodeHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP reporting member down.
|
|
|
|
Action required:
|
|
Check the connection status of LAG members on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Find the bond(uplink) which is
|
|
reporting degraded or down.
|
|
4. Check the LACP member status details by logging into the failed host and
|
|
invoking `esxcli network vswitch dvs vmware lacp status get` on an ESXi
|
|
host or `ovs-appctl bond/show` and `ovs-appctl lacp/show` on a KVM host.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 5 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP reporting member up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 6 }
|
|
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going down.
|
|
|
|
Action required:
|
|
Check the physical NICs' status of uplinks on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Check the status details of the
|
|
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
|
|
ensure all uplink interfaces are connected and up regardless of whether they
|
|
are in use or not.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 3 }
|
|
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 4 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going down.
|
|
|
|
Action required:
|
|
Check the physical NICs' status of uplinks on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Check the status details of the
|
|
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
|
|
ensure all uplink interfaces are connected and up regardless of whether they
|
|
are in use or not.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 7 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- VPN feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTVPNFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the VPN feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 15 }
|
|
|
|
vmwNsxTVPNFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for VPN feature notifications.
|
|
"
|
|
::= { vmwNsxTVPNFeaturePrefix 0 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSessionDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterSessionDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
session down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 7 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 8 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are down.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
tunnel down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 9 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 10 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSessionDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterSessionDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
session down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 11 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 12 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTunnelDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterTunnelDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
tunnel down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 13 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 14 }
|
|
|
|
vmwNsxTVPNIPsecServiceDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPsec service vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterServiceDownReason.
|
|
|
|
Action required:
|
|
1. Disable and enable the IPsec service from NSX Manager UI.
|
|
2. If the issue still persists, check syslog for error logs and contact
|
|
VMware support.
|
|
"
|
|
::= { vmwNsxTVPNFeature 17 }
|
|
|
|
vmwNsxTVPNIPsecServiceDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPsec service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 18 }
|
|
|
|
vmwNsxTVPNL2VpnSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The L2VPN session vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Check L2VPN session status for session down reason and resolve errors based
|
|
on the reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 15 }
|
|
|
|
vmwNsxTVPNL2VpnSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The L2VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 16 }
|
|
|
|
-- **********************************************************
|
|
-- Conformance information
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterConformance OBJECT IDENTIFIER ::= { vmwNSXsysMIB 2 }
|
|
vmwNsxTDataCenterCompliances OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 1 }
|
|
vmwNsxTDataCenterSMIBGroups OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 2 }
|
|
|
|
-- **********************************************************
|
|
-- Compliance statements
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterBasicCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationGroup
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 1 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterCurrentServiceState,
|
|
vmwNsxTDataCenterDHCPPoolUsage,
|
|
vmwNsxTDataCenterDHCPServerId,
|
|
vmwNsxTDataCenterDatapathResourceUsage,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterDuplicateIPAddress,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId,
|
|
vmwNsxTDataCenterFailureReason,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterPasswordExpirationDays,
|
|
vmwNsxTDataCenterPeerAddress,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterSessionDownReason,
|
|
vmwNsxTDataCenterSrId,
|
|
vmwNsxTDataCenterStaticAddress,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold,
|
|
vmwNsxTDataCenterTunnelDownReason,
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 1 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTAlarmManagementAlarmServiceOverloaded,
|
|
vmwNsxTAlarmManagementAlarmServiceOverloadedClear,
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarms,
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear,
|
|
vmwNsxTCertificatesCertificateExpirationApproaching,
|
|
vmwNsxTCertificatesCertificateExpirationApproachingClear,
|
|
vmwNsxTCertificatesCertificateExpired,
|
|
vmwNsxTCertificatesCertificateExpiredClear,
|
|
vmwNsxTCertificatesCertificateIsAboutToExpire,
|
|
vmwNsxTCertificatesCertificateIsAboutToExpireClear,
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDown,
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownClear,
|
|
vmwNsxTDHCPPoolLeaseAllocationFailed,
|
|
vmwNsxTDHCPPoolLeaseAllocationFailedClear,
|
|
vmwNsxTDHCPPoolOverloaded,
|
|
vmwNsxTDHCPPoolOverloadedClear,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear,
|
|
vmwNsxTDNSForwarderDisabled,
|
|
vmwNsxTDNSForwarderDisabledClear,
|
|
vmwNsxTDNSForwarderDown,
|
|
vmwNsxTDNSForwarderDownClear,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure,
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown,
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDown,
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear,
|
|
vmwNsxTEndpointProtectionEAMStatusDown,
|
|
vmwNsxTEndpointProtectionEAMStatusDownClear,
|
|
vmwNsxTEndpointProtectionPartnerChannelDown,
|
|
vmwNsxTEndpointProtectionPartnerChannelDownClear,
|
|
vmwNsxTHighAvailabilityTier0GatewayFailover,
|
|
vmwNsxTHighAvailabilityTier0GatewayFailoverClear,
|
|
vmwNsxTHighAvailabilityTier1GatewayFailover,
|
|
vmwNsxTHighAvailabilityTier1GatewayFailoverClear,
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown,
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDown,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear,
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected,
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear,
|
|
vmwNsxTIntelligenceHealthCPUUsageHigh,
|
|
vmwNsxTIntelligenceHealthCPUUsageHighClear,
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthDiskUsageHigh,
|
|
vmwNsxTIntelligenceHealthDiskUsageHighClear,
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthMemoryUsageHigh,
|
|
vmwNsxTIntelligenceHealthMemoryUsageHighClear,
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthNodeStatusDegraded,
|
|
vmwNsxTIntelligenceHealthNodeStatusDegradedClear,
|
|
vmwNsxTLicensesLicenseExpired,
|
|
vmwNsxTLicensesLicenseExpiredClear,
|
|
vmwNsxTLicensesLicenseIsAboutToExpire,
|
|
vmwNsxTLicensesLicenseIsAboutToExpireClear,
|
|
vmwNsxTLoadBalancerLBCPUVeryHigh,
|
|
vmwNsxTLoadBalancerLBCPUVeryHighClear,
|
|
vmwNsxTLoadBalancerLBStatusDown,
|
|
vmwNsxTLoadBalancerLBStatusDownClear,
|
|
vmwNsxTLoadBalancerPoolStatusDown,
|
|
vmwNsxTLoadBalancerPoolStatusDownClear,
|
|
vmwNsxTLoadBalancerVirtualServerStatusDown,
|
|
vmwNsxTLoadBalancerVirtualServerStatusDownClear,
|
|
vmwNsxTManagerHealthDuplicateIPAddress,
|
|
vmwNsxTManagerHealthDuplicateIPAddressClear,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHigh,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerCPUUsageHigh,
|
|
vmwNsxTManagerHealthManagerCPUUsageHighClear,
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerDiskUsageHigh,
|
|
vmwNsxTManagerHealthManagerDiskUsageHighClear,
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerMemoryUsageHigh,
|
|
vmwNsxTManagerHealthManagerMemoryUsageHighClear,
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear,
|
|
vmwNsxTNCPHealthNCPPluginDown,
|
|
vmwNsxTNCPHealthNCPPluginDownClear,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDown,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownClear,
|
|
vmwNsxTPasswordManagementPasswordExpirationApproaching,
|
|
vmwNsxTPasswordManagementPasswordExpirationApproachingClear,
|
|
vmwNsxTPasswordManagementPasswordExpired,
|
|
vmwNsxTPasswordManagementPasswordExpiredClear,
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpire,
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear,
|
|
vmwNsxTRoutingBFDDownOnExternalInterface,
|
|
vmwNsxTRoutingBFDDownOnExternalInterfaceClear,
|
|
vmwNsxTRoutingBGPDown,
|
|
vmwNsxTRoutingBGPDownClear,
|
|
vmwNsxTRoutingRoutingDown,
|
|
vmwNsxTRoutingRoutingDownClear,
|
|
vmwNsxTRoutingStaticRoutingRemoved,
|
|
vmwNsxTRoutingStaticRoutingRemovedClear,
|
|
vmwNsxTTransportNodeHealthLAGMemberDown,
|
|
vmwNsxTTransportNodeHealthLAGMemberDownClear,
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDown,
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDownClear,
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDown,
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDownClear,
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDown,
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear,
|
|
vmwNsxTVPNIPsecRouteBasedSessionDown,
|
|
vmwNsxTVPNIPsecRouteBasedSessionDownClear,
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDown,
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDownClear,
|
|
vmwNsxTVPNL2VpnSessionDown,
|
|
vmwNsxTVPNL2VpnSessionDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 2 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 2 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 3 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup2 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTEdgeHealthStorageError,
|
|
vmwNsxTEdgeHealthStorageErrorClear,
|
|
vmwNsxTFederationLmToLmSynchronizationError,
|
|
vmwNsxTFederationLmToLmSynchronizationErrorClear,
|
|
vmwNsxTFederationLmToLmSynchronizationWarning,
|
|
vmwNsxTFederationLmToLmSynchronizationWarningClear,
|
|
vmwNsxTFederationRtepBGPDown,
|
|
vmwNsxTFederationRtepBGPDownClear,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHigh,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 4 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 3 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterRxMisses,
|
|
vmwNsxTDataCenterRxProcessed,
|
|
vmwNsxTDataCenterTransportNodeAddress,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTxMisses,
|
|
vmwNsxTDataCenterTxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 5 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup3 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDown,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear,
|
|
vmwNsxTCommunicationManagerControlChannelDown,
|
|
vmwNsxTCommunicationManagerControlChannelDownClear,
|
|
vmwNsxTFederationRtepConnectivityLost,
|
|
vmwNsxTFederationRtepConnectivityLostClear,
|
|
vmwNsxTManagerHealthStorageError,
|
|
vmwNsxTManagerHealthStorageErrorClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 6 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance4 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 4 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup4 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterActiveGlobalManager,
|
|
vmwNsxTDataCenterActiveGlobalManagers,
|
|
vmwNsxTDataCenterApplianceFQDN,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterCentralControlPlaneId,
|
|
vmwNsxTDataCenterDirectoryDomain,
|
|
vmwNsxTDataCenterDisplayedLicenseKey,
|
|
vmwNsxTDataCenterEdgeThreadName,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterLDAPServer,
|
|
vmwNsxTDataCenterLatencySource,
|
|
vmwNsxTDataCenterLatencyThreshold,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterMaxCapacityThreshold,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold,
|
|
vmwNsxTDataCenterRemoteApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 7 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup4 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateError,
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear,
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerError,
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear,
|
|
vmwNsxTCapacityMaximumCapacity,
|
|
vmwNsxTCapacityMaximumCapacityClear,
|
|
vmwNsxTCapacityMaximumCapacityThreshold,
|
|
vmwNsxTCapacityMaximumCapacityThresholdClear,
|
|
vmwNsxTCapacityMinimumCapacityThreshold,
|
|
vmwNsxTCapacityMinimumCapacityThresholdClear,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDown,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownClear,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDown,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownClear,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLong,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear,
|
|
vmwNsxTCommunicationManagerClusterLatencyHigh,
|
|
vmwNsxTCommunicationManagerClusterLatencyHighClear,
|
|
vmwNsxTCommunicationManagerFQDNLookupFailure,
|
|
vmwNsxTCommunicationManagerFQDNLookupFailureClear,
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailure,
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear,
|
|
vmwNsxTDistributedIDSIPSMaxEventsReached,
|
|
vmwNsxTDistributedIDSIPSMaxEventsReachedClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlocked,
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear,
|
|
vmwNsxTFederationGMToGMSplitBrain,
|
|
vmwNsxTFederationGMToGMSplitBrainClear,
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost,
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear,
|
|
vmwNsxTIdentityFirewallErrorInDeltaSync,
|
|
vmwNsxTIdentityFirewallErrorInDeltaSyncClear,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknown,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownClear,
|
|
vmwNsxTIntelligenceHealthStorageLatencyHigh,
|
|
vmwNsxTIntelligenceHealthStorageLatencyHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 8 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance5 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 5 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup5 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTRoutingOSPFNeighborWentDown,
|
|
vmwNsxTRoutingOSPFNeighborWentDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 10 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance6 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 6 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup6 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterServiceIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 11 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup6 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP,
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 12 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance7 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 7 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup7 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 13 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup7 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTIPAMIPBlockUsageVeryHigh,
|
|
vmwNsxTIPAMIPBlockUsageVeryHighClear,
|
|
vmwNsxTIPAMIPPoolUsageVeryHigh,
|
|
vmwNsxTIPAMIPPoolUsageVeryHighClear,
|
|
vmwNsxTLoadBalancerDLBStatusDown,
|
|
vmwNsxTLoadBalancerDLBStatusDownClear,
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh,
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear,
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh,
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear,
|
|
vmwNsxTLoadBalancerLBStatusDegraded,
|
|
vmwNsxTLoadBalancerLBStatusDegradedClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 14 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance8 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 8 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup8 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 15 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup8 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTDNSForwarderUpstreamServerTimeout,
|
|
vmwNsxTDNSForwarderUpstreamServerTimeoutClear,
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallICMPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallICMPFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallIPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallIPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallIPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallIPFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallUDPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallUDPFlowCountHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 16 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance9 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 9 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup9 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterAPICollectionPath,
|
|
vmwNsxTDataCenterCABundleAgeThreshold,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName,
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason,
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason,
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason,
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason,
|
|
vmwNsxTDataCenterFirewallSNATPortsUsage,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterGroupType,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold,
|
|
vmwNsxTDataCenterNappNodeId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterNappServiceName,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterServiceDownReason,
|
|
vmwNsxTDataCenterServiceRouterId,
|
|
vmwNsxTDataCenterSyncIssueReason,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 17 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup9 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCertificatesCABundleUpdateRecommended,
|
|
vmwNsxTCertificatesCABundleUpdateRecommendedClear,
|
|
vmwNsxTCertificatesCABundleUpdateSuggested,
|
|
vmwNsxTCertificatesCABundleUpdateSuggestedClear,
|
|
vmwNsxTClusteringClusterDegraded,
|
|
vmwNsxTClusteringClusterDegradedClear,
|
|
vmwNsxTClusteringClusterUnavailable,
|
|
vmwNsxTClusteringClusterUnavailableClear,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDown,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear,
|
|
vmwNsxTDistributedFirewallDFWSessionCountHigh,
|
|
vmwNsxTDistributedFirewallDFWSessionCountHighClear,
|
|
vmwNsxTDistributedFirewallDFWVmotionFailure,
|
|
vmwNsxTDistributedFirewallDFWVmotionFailureClear,
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged,
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear,
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatch,
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatchClear,
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch,
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear,
|
|
vmwNsxTEdgeEdgevSphereLocationMismatch,
|
|
vmwNsxTEdgeEdgevSphereLocationMismatchClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear,
|
|
vmwNsxTEdgeHealthFailureDomainDown,
|
|
vmwNsxTEdgeHealthFailureDomainDownClear,
|
|
vmwNsxTFederationGMToGMLatencyWarning,
|
|
vmwNsxTFederationGMToGMLatencyWarningClear,
|
|
vmwNsxTFederationGMToGMSynchronizationError,
|
|
vmwNsxTFederationGMToGMSynchronizationErrorClear,
|
|
vmwNsxTFederationGMToGMSynchronizationWarning,
|
|
vmwNsxTFederationGMToGMSynchronizationWarningClear,
|
|
vmwNsxTFederationGMToLMLatencyWarning,
|
|
vmwNsxTFederationGMToLMLatencyWarningClear,
|
|
vmwNsxTFederationGMToLMSynchronizationError,
|
|
vmwNsxTFederationGMToLMSynchronizationErrorClear,
|
|
vmwNsxTFederationGMToLMSynchronizationWarning,
|
|
vmwNsxTFederationGMToLMSynchronizationWarningClear,
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgress,
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear,
|
|
vmwNsxTFederationQueueOccupancyThresholdExceeded,
|
|
vmwNsxTFederationQueueOccupancyThresholdExceededClear,
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory,
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear,
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBig,
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear,
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZone,
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear,
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHigh,
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected,
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDown,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear,
|
|
vmwNsxTVPNIPsecServiceDown,
|
|
vmwNsxTVPNIPsecServiceDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 18 }
|
|
|
|
END
|