mibs/MIBS/watchguard/WATCHGUARD-SYSTEM-CONFIG-MIB
2023-12-05 12:25:34 +01:00

168 lines
4.1 KiB
Plaintext

WATCHGUARD-SYSTEM-CONFIG-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32,
Integer32, Unsigned32, IpAddress, Gauge32,
enterprises, NOTIFICATION-TYPE FROM SNMPv2-SMI
watchguard FROM WATCHGUARD-SMI;
wgSystemConfigMIB MODULE-IDENTITY
LAST-UPDATED "200811100000Z"
ORGANIZATION "WatchGuard Technologies, Inc."
CONTACT-INFO
" WatchGuard Technologies, Inc.
505 Fifth Avenue South
Suite 500
Seattle, WA 98104
United States
+1.206.613.6600 "
DESCRIPTION
"This MIB module defines WatchGuard Firebox system
configuration."
REVISION "200701251200Z"
DESCRIPTION
"Initial revision."
REVISION "200811100000Z"
DESCRIPTION
"Updated CONTACT-INFO."
::= { watchguard 2 }
-- significant branches
wgSysTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the base object for system wide traps
in this entity."
::= { wgSystemConfigMIB 3 }
wgSysTrapObjects OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the base object for objects which are used
as part of traps."
::= { wgSystemConfigMIB 4 }
wgSysTrapControl OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This is the base object identifier for all objects
which are trap control for the entity."
::= { wgSystemConfigMIB 5 }
--
-- wgSysTraps
--
-- object used in trap reporting
wgAlarmId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The id of the alarm that generates a trap."
::= { wgSysTrapObjects 1 }
wgAlarmLabel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the alarm that generates a trap."
::= { wgSysTrapObjects 2 }
wgAlarmTime OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time of the alarm that generates a trap."
::= { wgSysTrapObjects 3 }
wgAlarmLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(4),
warning(3),
error(2),
critical(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of an alarm generated."
::= { wgSysTrapObjects 4 }
wgAlarmHostname OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host name of the system where alarm occurred"
::= { wgSysTrapObjects 5 }
wgAlarmMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The message describing the nature of this alarm."
::= { wgSysTrapObjects 6 }
--
-- trap control
--
wgAlarmTrapEnable OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether wgAlarmTrap trap should be generated."
DEFVAL { true }
::= { wgSysTrapControl 1 }
--
-- traps themselves
--
wgSysTrapsPrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION ""
::= { wgSysTraps 0 }
wgAlarmTrap NOTIFICATION-TYPE
OBJECTS {
wgAlarmId,
wgAlarmLabel,
wgAlarmTime,
wgAlarmLevel,
wgAlarmHostname,
wgAlarmMsg
}
STATUS current
DESCRIPTION
"An alarm was raised by Monitoring Agent of this
WatchGuard entity."
::= { wgSysTrapsPrefix 1 }
wgSnmpShutdown NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent when the snmp terminates."
::= { wgSysTrapsPrefix 2 }
wgSnmpStart NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent when the snmp starts."
::= { wgSysTrapsPrefix 3 }
END