mibs/MIBS/wti/WTI-POWER-MIB
2023-12-05 12:25:34 +01:00

951 lines
24 KiB
Plaintext

--
-- Copyright(C) 2016 Western Telematic, Inc.
--
WTI-POWER-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, NOTIFICATION-TYPE,
OBJECT-TYPE, enterprises FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC;
westernTelematic OBJECT IDENTIFIER ::= { enterprises 2634 }
power MODULE-IDENTITY
LAST-UPDATED "201604011600Z" -- 01 Apr 2016
ORGANIZATION "Western Telematic, Inc."
CONTACT-INFO
"Western Telematic, Inc.
5 Sterling
Irvine, Ca 92618
Email: anthonyb@wti.com"
DESCRIPTION
"This is the MIB module for power products"
REVISION "201604011600Z" -- 01 Apr 2016
DESCRIPTION
"V6.00 for power products "
::= { westernTelematic 3 }
--
-- System Tables
--
systemTables OBJECT IDENTIFIER ::= { power 100 }
--
-- Plug Table
--
plugTable OBJECT-TYPE
SYNTAX SEQUENCE OF PlugEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of plugs."
::= { systemTables 200 }
plugEntry OBJECT-TYPE
SYNTAX PlugEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the plug table."
INDEX { plugIndex }
::= { plugTable 1 }
PlugEntry ::= SEQUENCE {
plugIndex INTEGER,
plugID DisplayString,
plugStatus INTEGER,
plugAction INTEGER,
plugName DisplayString,
plugCurrent INTEGER,
plugPower INTEGER
}
plugIndex OBJECT-TYPE
SYNTAX INTEGER (0..80)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the plug table."
::= { plugEntry 1 }
plugID OBJECT-TYPE
SYNTAX DisplayString(SIZE(9..11))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the plug."
::= { plugEntry 2 }
plugStatus OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Plug status"
::= { plugEntry 3 }
plugAction OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Plug action"
::= { plugEntry 4 }
plugName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Name of the plug."
::= { plugEntry 5 }
plugCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Plug current (In tenths of amps, divide by 10 for value in amps)"
::= { plugEntry 7 }
plugPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Plug power (Watts)"
::= { plugEntry 8 }
--
-- Plug Group Table
--
plugGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF PlugGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of plug groups."
::= { systemTables 300 }
plugGroupEntry OBJECT-TYPE
SYNTAX PlugGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the plug group table."
INDEX { plugGroupIndex }
::= { plugGroupTable 1 }
PlugGroupEntry ::= SEQUENCE {
plugGroupIndex INTEGER,
plugGroupName DisplayString,
plugGroupAction INTEGER,
plugGroupCurrent INTEGER,
plugGroupPower INTEGER
}
plugGroupIndex OBJECT-TYPE
SYNTAX INTEGER (0..54)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the plug group table."
::= { plugGroupEntry 1 }
plugGroupName OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..24))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the plug group."
::= { plugGroupEntry 2 }
plugGroupAction OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Plug group action"
::= { plugGroupEntry 3 }
plugGroupCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Plug group current (In tenths of amps, divide by 10 for value in amps)"
::= { plugGroupEntry 4 }
plugGroupPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Plug group power (Watts)"
::= { plugGroupEntry 5 }
--
-- User Table
--
userTable OBJECT-TYPE
SYNTAX SEQUENCE OF UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of users."
::= { systemTables 400 }
userEntry OBJECT-TYPE
SYNTAX UserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the user table."
INDEX { userIndex }
::= { userTable 1 }
UserEntry ::= SEQUENCE {
userIndex INTEGER,
userName DisplayString,
userPasswd DisplayString,
userAccessLevel INTEGER,
userPortAccess DisplayString,
userLocalAccess DisplayString,
userGroupAccess DisplayString,
userSerialAccess INTEGER,
userTelnetSshAccess INTEGER,
userWebAccess INTEGER,
userCurrentPowerMetering INTEGER,
userCallbackNum DisplayString,
userSubmit INTEGER
}
userIndex OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the user table."
::= { userEntry 1 }
userName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the user."
::= { userEntry 2 }
userPasswd OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password of the user."
::= { userEntry 3 }
userAccessLevel OBJECT-TYPE
SYNTAX INTEGER (0..3)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Users access level"
::= { userEntry 4 }
userPortAccess OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to ports."
::= { userEntry 5 }
userLocalAccess OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to LOCAL plugs."
::= { userEntry 6 }
userGroupAccess OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..54))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to plug groups."
::= { userEntry 10 }
userSerialAccess OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to serial interface."
::= { userEntry 11 }
userTelnetSshAccess OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to Telnet/SSH interface."
::= { userEntry 12 }
userWebAccess OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to web interface."
::= { userEntry 13 }
userCurrentPowerMetering OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Access to Current/Power Metering."
::= { userEntry 15 }
userCallbackNum OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Callback number."
::= { userEntry 16 }
userSubmit OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Submit changes to user."
::= { userEntry 31 }
--
-- Environment Tables
--
environmentTables OBJECT IDENTIFIER ::= { power 200 }
environmentUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvironmentUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of environment status for units."
::= { environmentTables 10 }
environmentUnitEntry OBJECT-TYPE
SYNTAX EnvironmentUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Row definition for the environment unit table."
INDEX { environmentUnitIndex }
::= { environmentUnitTable 1 }
EnvironmentUnitEntry ::= SEQUENCE {
environmentUnitIndex INTEGER,
environmentUnitName DisplayString,
environmentUnitTemperature INTEGER,
environmentUnitCurrentA INTEGER,
environmentUnitVoltageA INTEGER,
environmentUnitPowerA INTEGER,
environmentUnitCurrentB INTEGER,
environmentUnitVoltageB INTEGER,
environmentUnitPowerB INTEGER,
environmentUnitCurrentC INTEGER,
environmentUnitVoltageC INTEGER,
environmentUnitPowerC INTEGER,
environmentUnitCurrentD INTEGER,
environmentUnitVoltageD INTEGER,
environmentUnitPowerD INTEGER,
environmentSysRAM INTEGER,
environmentSysFlash INTEGER,
environmentMacEth0 DisplayString,
environmentMacEth1 DisplayString,
environmentInputPower1 INTEGER,
environmentInputPower2 INTEGER,
environmentInputPower3 INTEGER,
environmentInputPower4 INTEGER
}
environmentUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the environment unit table."
::= { environmentUnitEntry 1 }
environmentUnitName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the unit."
::= { environmentUnitEntry 2 }
environmentUnitTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature of the unit."
::= { environmentUnitEntry 3 }
environmentUnitCurrentA OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of amps in branch A for unit (In tenths of amps, divide by 10 for value in amps)."
::= { environmentUnitEntry 4 }
environmentUnitVoltageA OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage of branch A for unit."
::= { environmentUnitEntry 5 }
environmentUnitPowerA OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of watts used by branch A for unit."
::= { environmentUnitEntry 6 }
environmentUnitCurrentB OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of amps in branch B for unit (In tenths of amps, divide by 10 for value in amps)."
::= { environmentUnitEntry 7 }
environmentUnitVoltageB OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage of branch B for unit."
::= { environmentUnitEntry 8 }
environmentUnitPowerB OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of watts used by branch b for unit."
::= { environmentUnitEntry 9 }
environmentUnitCurrentC OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of amps in branch C for unit (In tenths of amps, divide by 10 for value in amps)."
::= { environmentUnitEntry 10 }
environmentUnitVoltageC OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage of branch C for unit."
::= { environmentUnitEntry 11 }
environmentUnitPowerC OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of watts used by branch c for unit."
::= { environmentUnitEntry 12 }
environmentUnitCurrentD OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of amps in branch D for unit (In tenths of amps, divide by 10 for value in amps)."
::= { environmentUnitEntry 13 }
environmentUnitVoltageD OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage of branch D for unit."
::= { environmentUnitEntry 14 }
environmentUnitPowerD OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of watts used by branch d for unit."
::= { environmentUnitEntry 15 }
environmentSysRAM OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total system RAM."
::= { environmentUnitEntry 18 }
environmentSysFlash OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total system Flash."
::= { environmentUnitEntry 19 }
environmentMacEth0 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address Eth0"
::= { environmentUnitEntry 20 }
environmentMacEth1 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address Eth1"
::= { environmentUnitEntry 21 }
environmentInputPower1 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of first power input."
::= { environmentUnitEntry 22 }
environmentInputPower2 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of second power input."
::= { environmentUnitEntry 23 }
environmentInputPower3 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of third power input."
::= { environmentUnitEntry 24 }
environmentInputPower4 OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of fourth power input."
::= { environmentUnitEntry 25 }
environmentBranchATotalCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Current on BRANCH A (In tenths of amps, divide by 10 for value in amps)."
::= { environmentTables 20 }
environmentBranchATotalPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Power on BRANCH A."
::= { environmentTables 30 }
environmentBranchBTotalCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Current on BRANCH B (In tenths of amps, divide by 10 for value in amps)."
::= { environmentTables 40 }
environmentBranchBTotalPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Power on BRANCH B."
::= { environmentTables 50 }
environmentBranchCTotalCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Current on BRANCH C (In tenths of amps, divide by 10 for value in amps)."
::= { environmentTables 51 }
environmentBranchCTotalPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Power on BRANCH C."
::= { environmentTables 52 }
environmentBranchDTotalCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Current on BRANCH D (In tenths of amps, divide by 10 for value in amps)."
::= { environmentTables 53 }
environmentBranchDTotalPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Power on BRANCH D."
::= { environmentTables 54 }
environmentSystemTotalCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total current for system (In tenths of amps, divide by 10 for value in amps)."
::= { environmentTables 60 }
environmentSystemTotalPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total power on system."
::= { environmentTables 70 }
environmentMonthlyPowerLog OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The monthly power usage log"
::= { environmentTables 80 }
--
-- Alarm Tables
--
alarmTables OBJECT IDENTIFIER ::= { power 280 }
alarmOverCurrentInitial OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Over Current Initial Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 1 }
alarmOverCurrentCritical OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Over Current Critical Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 2 }
alarmOverTemperatureInitial OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Over Temperature Initial Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 3 }
alarmOverTemperatureCritical OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Over Temperature Critical Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 4 }
alarmCircuitBreakerOpen OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Circuit Breaker Open Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 5 }
alarmCommLoss OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Communication Loss Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 6 }
alarmLostVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 7 }
alarmPingNoAnswer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Ping No Answer Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 8 }
alarmInvalidAccessLockout OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Invalid Access Lockout Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 9 }
alarmPowerCycle OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Power Cycle Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 10 }
alarmAlarmInput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Alarm Input Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 12 }
alarmPlugCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Plug Current Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 13 }
alarmLostOptoVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Lost Voltage (Line Input) Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 14 }
alarmEmergencyShutoff OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the Emergency Shutoff Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 15 }
alarmNoDialtone OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the No Dialtone Alarm (0 = Inactive, 1 = Active)"
::= { alarmTables 16 }
--
-- Traps
--
wtiTraps OBJECT IDENTIFIER ::= { power 300 }
-- Trap Info
trapInfo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm information"
::= { wtiTraps 1 }
-- Test Traps
testTraps OBJECT IDENTIFIER ::= { wtiTraps 2}
testTrap TRAP-TYPE
ENTERPRISE testTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"A test trap"
::= 1
-- Alarm Traps
overCurrentInitialTraps OBJECT IDENTIFIER ::= { wtiTraps 4}
overCurrentInitialSetTrap TRAP-TYPE
ENTERPRISE overCurrentInitialTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Current Initial Alarm"
::= 1
overCurrentInitialClearTrap TRAP-TYPE
ENTERPRISE overCurrentInitialTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Current Initial Alarm (Clear)"
::= 2
overCurrentCriticalTraps OBJECT IDENTIFIER ::= { wtiTraps 5}
overCurrentCriticalSetTrap TRAP-TYPE
ENTERPRISE overCurrentCriticalTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Current Critical Alarm"
::= 1
overCurrentCriticalClearTrap TRAP-TYPE
ENTERPRISE overCurrentCriticalTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Current Critical Alarm (Clear)"
::= 2
overTemperatureInitialTraps OBJECT IDENTIFIER ::= { wtiTraps 6}
overTemperatureInitialSetTrap TRAP-TYPE
ENTERPRISE overTemperatureInitialTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Temperature Initial Alarm"
::= 1
overTemperatureInitialClearTrap TRAP-TYPE
ENTERPRISE overTemperatureInitialTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Temperature Initial Alarm (Clear)"
::= 2
overTemperatureCriticalTraps OBJECT IDENTIFIER ::= { wtiTraps 7}
overTemperatureCriticalSetTrap TRAP-TYPE
ENTERPRISE overTemperatureCriticalTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Temperature Critical Alarm"
::= 1
overTemperatureCriticalClearTrap TRAP-TYPE
ENTERPRISE overTemperatureCriticalTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Over Temperature Critical Alarm (Clear)"
::= 2
circuitBreakerOpenTraps OBJECT IDENTIFIER ::= { wtiTraps 8}
circuitBreakerOpenSetTrap TRAP-TYPE
ENTERPRISE circuitBreakerOpenTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Circuit Breaker Open Alarm"
::= 1
circuitBreakerOpenClearTrap TRAP-TYPE
ENTERPRISE circuitBreakerOpenTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Circuit Breaker Open Alarm (Clear)"
::= 2
lostCommTraps OBJECT IDENTIFIER ::= { wtiTraps 9}
lostCommSetTrap TRAP-TYPE
ENTERPRISE lostCommTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Communication with AUX Unit"
::= 1
lostCommClearTrap TRAP-TYPE
ENTERPRISE lostCommTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Communication with AUX Unit (Clear)"
::= 2
lostVoltageTraps OBJECT IDENTIFIER ::= { wtiTraps 10}
lostVoltageSetTrap TRAP-TYPE
ENTERPRISE lostVoltageTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Voltage (Line In)"
::= 1
lostVoltageClearTrap TRAP-TYPE
ENTERPRISE lostVoltageTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Voltage (Line In) (Clear)"
::= 2
pingNoAnswerTraps OBJECT IDENTIFIER ::= { wtiTraps 11}
pingNoAnswerSetTrap TRAP-TYPE
ENTERPRISE pingNoAnswerTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Ping No Answer"
::= 1
pingNoAnswerClearTrap TRAP-TYPE
ENTERPRISE pingNoAnswerTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Ping No Answer (Clear)"
::= 2
lockoutTraps OBJECT IDENTIFIER ::= { wtiTraps 12}
lockoutSetTrap TRAP-TYPE
ENTERPRISE lockoutTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Invalid Access Lockout"
::= 1
lockoutClearTrap TRAP-TYPE
ENTERPRISE lockoutTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Invalid Access Lockout (Clear)"
::= 2
powercycleTraps OBJECT IDENTIFIER ::= { wtiTraps 13}
powercycleSetTrap TRAP-TYPE
ENTERPRISE powercycleTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Power Cycle"
::= 1
alarmInputTraps OBJECT IDENTIFIER ::= { wtiTraps 14}
alarmInputSetTrap TRAP-TYPE
ENTERPRISE alarmInputTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Alarm Input"
::= 1
alarmInputClearTrap TRAP-TYPE
ENTERPRISE alarmInputTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Alarm Input (Clear)"
::= 2
plugCurrentTraps OBJECT IDENTIFIER ::= { wtiTraps 15}
plugCurrentSetTrap TRAP-TYPE
ENTERPRISE plugCurrentTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Plug Current"
::= 1
plugCurrentClearTrap TRAP-TYPE
ENTERPRISE plugCurrentTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Plug Current (Clear)"
::= 2
lostOptoVoltageTraps OBJECT IDENTIFIER ::= { wtiTraps 16}
lostOptoVoltageSetTrap TRAP-TYPE
ENTERPRISE lostOptoVoltageTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Voltage"
::= 1
lostOptoVoltageClearTrap TRAP-TYPE
ENTERPRISE lostOptoVoltageTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Lost Voltage (Clear)"
::= 2
emergencyShutoffTraps OBJECT IDENTIFIER ::= { wtiTraps 17}
emergencyShutoffSetTrap TRAP-TYPE
ENTERPRISE emergencyShutoffTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Emergency Shutoff"
::= 1
emergencyShutoffClearTrap TRAP-TYPE
ENTERPRISE emergencyShutoffTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"Emergency Shutoff (Clear)"
::= 2
noDialtoneTraps OBJECT IDENTIFIER ::= { wtiTraps 18}
noDialtoneSetTrap TRAP-TYPE
ENTERPRISE noDialtoneTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"No Dialtone"
::= 1
noDialtoneClearTrap TRAP-TYPE
ENTERPRISE noDialtoneTraps
VARIABLES {
trapInfo
}
DESCRIPTION
"No Dialtone (Clear)"
::= 2
END