mibs/MIBS/zyxel/ZYXEL-AESCOMMON-MIB
2023-12-05 12:25:34 +01:00

559 lines
15 KiB
Plaintext

-- ZyXEL Communications Corporation
-- Private Enterprise MIB definition
-- $Log: zyxel-AESCommon.mib $
-- Revision 1.1 2006/08/28 05:32:51 kenny
-- Initial revision
-- Revision 1.3 2006/04/06 14:50:30 niceguy
-- Revision 1.2 2006/03/10 06:07:54 niceguy
-- Revision 1.1 2005/11/23 12:47:53 niceguy
-- Initial revision
-- Revision 1.1 2005/08/18 13:30:37 Jeff
-- Initial revision
-- Revision 1.5 2005/06/08 08:04:08 jennyhsu
-- Changes for IES-2k/3k R3.02
-- Revision 1.4 2004/06/08 10:12:54 jenny
-- Add ADSL2 and ADSL2+ mode
-- Revision 1.3 2003/11/25 04:00:31 jennyhsu
-- add etsi mode
-- Revision 1.2 2002/11/12 07:48:38 jennyhsu
-- Revision 1.1 2002/11/12 07:40:54 jennyhsu
-- Initial revision
ZYXEL-AESCOMMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE FROM RFC-1212
DisplayString, ifIndex FROM RFC1213-MIB
Unsigned32 FROM SNMPv2-SMI
aesSeriesCommon FROM ZYXEL-MIB;
aesMaxNumOfProfiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of ADSL profiles which the system supports."
::= { aesSeriesCommon 1 }
aesLineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AesLineConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes common attributes describing the ADSL line."
::= { aesSeriesCommon 2 }
aesLineConfEntry OBJECT-TYPE
SYNTAX AesLineConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aesLineConfTable."
INDEX { ifIndex }
::= { aesLineConfTable 1 }
AesLineConfEntry ::=
SEQUENCE {
aesLineConfAdslMode INTEGER,
aesLineConfEncap INTEGER,
aesLineConfVpi INTEGER,
aesLineConfVci INTEGER,
aesLineConfAnnexL INTEGER,
aesLineConfPmMode INTEGER,
aesLineConfRateMode INTEGER,
aesLineConfAnnexM INTEGER
}
aesLineConfAdslMode OBJECT-TYPE
SYNTAX INTEGER {
gDotLite(1),
gDotDmt(2),
t1Dot413(3),
auto(4),
etsi(5),
adsl2(6),
adsl2Plus(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode of the ADSL line."
::= { aesLineConfEntry 1 }
aesLineConfEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The encapsulation of the ADSL line."
::= { aesLineConfEntry 2 }
aesLineConfVpi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VPI of the ADSL line."
::= { aesLineConfEntry 3 }
aesLineConfVci OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VCI of the ADSL line."
::= { aesLineConfEntry 4 }
aesLineConfAnnexL OBJECT-TYPE
SYNTAX INTEGER {
enableNarrowMode(1),
enableWideMode(2),
disable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The annex L setting of the ADSL line(Only in AnnexA)."
::= { aesLineConfEntry 5 }
aesLineConfPmMode OBJECT-TYPE
SYNTAX INTEGER {
enableL2Mode(1),
enableL3Mode(2),
disable(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The power management mode of the ADSL line."
::= { aesLineConfEntry 6 }
aesLineConfRateMode OBJECT-TYPE
SYNTAX INTEGER {
fixed(1), -- no rate adaptation
adaptAtStartup(2), -- perform rate adaptation
-- only at initialization
adaptAtRuntime(3) -- perform rate adaptation at
-- any time
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines what form of transmit rate adaptation is
configured on this modem. See ADSL Forum TR-005 [3]
for more information."
::= { aesLineConfEntry 7 }
aesLineConfAnnexM OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The annex M setting of the ADSL line."
::= { aesLineConfEntry 8 }
-- ADSL Line Diagnostic
aesLineDiagnostic OBJECT IDENTIFIER ::= { aesSeriesCommon 3 }
aesAtucLineDiagLATN OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Attenuation."
::= { aesLineDiagnostic 1 }
aesAtucLineDiagSATN OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Signal Attenuation."
::= { aesLineDiagnostic 2 }
aesAtucLineDiagSNRM OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Signal-to-Noise Ratio Margin."
::= { aesLineDiagnostic 3 }
aesAtucLineDiagACTATP OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { aesLineDiagnostic 4 }
aesAtucLineDiagATTNDR OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Attainable Net Data Rate, in bps."
::= { aesLineDiagnostic 5 }
aesAturLineDiagLATN OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Attenuation."
::= { aesLineDiagnostic 6 }
aesAturLineDiagSATN OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Signal Attenuation."
::= { aesLineDiagnostic 7 }
aesAturLineDiagSNRM OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Signal-to-Noise Ratio Margin."
::= { aesLineDiagnostic 8 }
aesAturLineDiagACTATP OBJECT-TYPE
SYNTAX INTEGER
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Actual Aggregate Transmit Power."
::= { aesLineDiagnostic 9 }
aesAturLineDiagATTNDR OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Attainable Net Data Rate, in bps."
::= { aesLineDiagnostic 10 }
aesLineDiagTarget OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ifindex of the ADSL port which will be diagnosed."
::= { aesLineDiagnostic 11 }
aesLineDiagOps OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The manager sets the object to one to start line diagnostics and the agent clears the
object to zero when diagnostics is successfully completed."
::= { aesLineDiagnostic 12 }
aesLineDiagFailReason OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reason of failed diagnostics."
::= { aesLineDiagnostic 13 }
-- ADSL Line Diagnostic Per Subcarrier
aesLineDiagPs OBJECT IDENTIFIER ::= { aesSeriesCommon 4 }
aesAtucNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of subcarriers per port for ATU-C."
::= { aesLineDiagPs 1 }
aesAturNumOfSubcarriersPerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of subcarriers per port for ATU-R."
::= { aesLineDiagPs 2 }
aesLineDiagPsCCFLirl1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value is the real
part of a complex value in liner scale.
The first two octets specify the li.rl value for subcarrier 1, and the second
two octets specify the li.rl value for subcarrier 2, and so on. The object
provides li.rl values for subcarrier 1 to 256."
::= { aesLineDiagPs 3 }
aesLineDiagPsCCFLirl2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value is the real
part of a complex value in liner scale.
The first two octets specify the li.rl value for subcarrier 257, and the second
two octets specify the li.rl value for subcarrier 258, and so on. The object
provides li.rl values for subcarrier 257 to 512."
::= { aesLineDiagPs 4 }
aesLineDiagPsCCFLiim1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value is the image
part of a complex value in liner scale.
The first two octets specify the li.im value for subcarrier 1, and the second
two octets specify the li.im value for subcarrier 2, and so on. The object
provides li.im values for subcarrier 1 to 256."
::= { aesLineDiagPs 5 }
aesLineDiagPsCCFLiim2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value is the image
part of a complex value in liner scale.
The first two octets specify the li.im value for subcarrier 257, and the second
two octets specify the li.im value for subcarrier 258, and so on. The object
provides li.im values for subcarrier 257 to 512."
::= { aesLineDiagPs 6 }
aesLineDiagPsCCFLog1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value
provides magnitude value in a logarithmic scale.
The first two octets specify the log value for subcarrier 1, and the second
two octets specify the log value for subcarrier 2, and so on. The object
provides log values for subcarrier 1 to 256."
::= { aesLineDiagPs 7 }
aesLineDiagPsCCFLog2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel Characteristics Function H(f) per subcarrier. The value
provides magnitude value in a logarithmic scale.
The first two octets specify the log value for subcarrier 257, and the second
two octets specify the log value for subcarrier 258, and so on. The object
provides log values for subcarrier 257 to 512."
::= { aesLineDiagPs 8 }
aesLineDiagPsQLN OBJECT-TYPE
SYNTAX OCTET STRING
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Quiet Line Noise PSD QLN(f) per subcarrier. The first octet specify QLN
for subcarrier 1, and the second octet specify QLN for subcarrier 2, and so on.
The object provides QLN for subcarrier 1 to 512."
::= { aesLineDiagPs 9 }
aesLineDiagPsSNR OBJECT-TYPE
SYNTAX OCTET STRING
UNITS "tenth dB"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Signal-to-Noise Ratio SNR(f) per subcarrier. The first octet specify SNR
for subcarrier 1, and the second octet specify SNR for subcarrier 2, and so on.
The object provides SNR for subcarrier 1 to 512."
::= { aesLineDiagPs 10 }
-- Max # of Alarm Profiles
aesMaxNumOfAlarmProfiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of ADSL alarm profiles which the system supports."
::= { aesSeriesCommon 5 }
-- Bit Loading
aesBitLoadingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AesBitLoadingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table provides the number of bits per carrier for each ADSL port."
::= { aesSeriesCommon 6 }
aesBitLoadingEntry OBJECT-TYPE
SYNTAX AesBitLoadingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aesBitLoadingTable."
INDEX { ifIndex }
::= { aesBitLoadingTable 1 }
AesBitLoadingEntry ::=
SEQUENCE {
aesBitLoadingBits OCTET STRING,
aesBitLoadingAtucNumOfCarriers INTEGER,
aesBitLoadingAturNumOfCarriers INTEGER
}
aesBitLoadingBits OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object provides the number of bits for all carriers in the port.
The first octet specify the number of bits for carrier 1, and the second
octet specify the number of bits for carrier 2, and so on.
The object provides the number of bits for carrier 1 to 512."
::= { aesBitLoadingEntry 1 }
aesBitLoadingAtucNumOfCarriers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of carriers for ATU-C."
::= { aesBitLoadingEntry 2 }
aesBitLoadingAturNumOfCarriers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of carriers for ATU-R."
::= { aesBitLoadingEntry 3 }
-- Line Status
aesLineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AesLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes the ADSL line status."
::= { aesSeriesCommon 7 }
aesLineStatusEntry OBJECT-TYPE
SYNTAX AesLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in aesLineStatusTable."
INDEX { ifIndex }
::= { aesLineStatusTable 1 }
AesLineStatusEntry ::=
SEQUENCE {
aesLineStatusAdslMode INTEGER
}
aesLineStatusAdslMode OBJECT-TYPE
SYNTAX INTEGER {
gDotLite(1),
gDotDmt(2),
t1Dot413(3),
etsi(4),
adsl2(5),
adsl2Plus(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link up mode of the ADSL line."
::= { aesLineStatusEntry 1 }
--------------------
-- selt
--------------------
selt OBJECT IDENTIFIER ::= { aesSeriesCommon 8 }
seltTarget OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IfIndex of the port which would be performed single end loopback test."
::= { selt 1 }
seltOps OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The manager sets the object to 1 to start the selt
and the agent clears the object to zero when selt is successfully completed."
::= { selt 2 }
seltStatus OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status description of the selt result."
::= { selt 3 }
seltCableType OBJECT-TYPE
SYNTAX INTEGER {
awg24(1),
awg26(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The cable type that selt result indicates."
::= { selt 4 }
seltLoopEstimateLengthFt OBJECT-TYPE
SYNTAX INTEGER
UNITS "feet"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 5 }
seltLoopEstimateLengthMeter OBJECT-TYPE
SYNTAX INTEGER
UNITS "meter"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The estimated loop length that selt result indicates."
::= { selt 6 }