From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/MEF-SOAM-PM-MIB | 7651 ++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 7651 insertions(+) create mode 100644 MIBS/MEF-SOAM-PM-MIB (limited to 'MIBS/MEF-SOAM-PM-MIB') diff --git a/MIBS/MEF-SOAM-PM-MIB b/MIBS/MEF-SOAM-PM-MIB new file mode 100644 index 0000000..50d62ee --- /dev/null +++ b/MIBS/MEF-SOAM-PM-MIB @@ -0,0 +1,7651 @@ +MEF-SOAM-PM-MIB DEFINITIONS ::= BEGIN + IMPORTS + NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, + Gauge32, enterprises + FROM SNMPv2-SMI -- RFC 2578 + RowStatus, TruthValue, MacAddress, DateAndTime, TimeInterval + FROM SNMPv2-TC -- RFC 2579 + OBJECT-GROUP, NOTIFICATION-GROUP, MODULE-COMPLIANCE + FROM SNMPv2-CONF -- RFC 2580 + dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, dot1agCfmMepEntry, + Dot1afCfmIndexIntegerNextFree, Dot1agCfmMepIdOrZero + FROM IEEE8021-CFM-MIB -- IEEE 802.1ag + IEEE8021PriorityValue + FROM IEEE8021-TC-MIB -- IEEE 802.1ap + MefSoamTcOperationTimeType, MefSoamTcDataPatternType, MefSoamTcTestPatternType, + MefSoamTcAvailabilityType, MefSoamTcDelayMeasurementBinType, + MefSoamTcMeasurementPeriodType, MefSoamTcSessionType, MefSoamTcStatusType + FROM MEF-SOAM-TC-MIB; + +mefSoamPmMib MODULE-IDENTITY + LAST-UPDATED "201201131200Z" -- January 13, 2012 + ORGANIZATION "Metro Ethernet Forum" + CONTACT-INFO + "Web URL: http://metroethernetforum.org/ + E-mail: mibs@metroethernetforum.org + Postal: Metro Ethernet Forum + 6033 W. Century Boulevard, Suite 830 + Los Angeles, CA 90045 + U.S.A. + Phone: +1 310-642-2800 + Fax: +1 310-642-2808" + DESCRIPTION + "This MIB module contains the management objects for the + management of Ethernet Services Operations, Administration + and Maintenance for Performance Monitoring. + + Copyright 2010, 2011, 2012 Metro Ethernet Forum + All rights reserved. + + **************************************************************************** + Reference Overview + + A number of base documents have been used to create the Textual Conventions + MIB, the SOAM-PM MIB and SOAM-FM extension MIB. The following are the + abbreviations for the baseline documents: + + [CFM] refers to 'Connectivity Fault Management', IEEE 802.1ag-2007, + December 2007 + [MEF7.1] refers to MEF 7.1 'Phase 2 EMS-NMS Information Model', + October 2009 + [MEF17] refers to MEF 17 'Service OAM Requirements & Framework - Phase 1', + April 2007 + [MEF10.2.1] refers to MEF 10.2.1 'Ethernet Services Attributes Phase 2', + January 2011 + [MEF SOAM-PM] refers to MEF 35 'Service OAM Performance Monitoring + Implementation Agreement', January 2012 + [MEF SOAM-FM] refers to MEF 30 'Service OAM Fault Management Implementation + Agreement', January 2011 + for NMS-EMS + management interface of Ethernet over Transport and Metro Ethernet + Network (EoT/MEN)', March 2007 + [Y.1731] refers to ITU-T Y.1731 'OAM functions and mechanisms for Ethernet + based networks', February 2011 + **************************************************************************** + + Abbreviations Used + + Term Definition + Availability Performance A measure of the percentage of time within a + specified time interval during which the frame loss is small + Backward OAM information sent from the Responder MEP to the Controller MEP. For + LM it indicates the frame counts/loss from the Responder MEP to the + Controller MEP. For DM is indicates the delay and delay variation + from the Responder MEP to the Controller MEP. + BSS Business Support System + CCM Continuity Check Message + CFM Connectivity Fault Management + CHLI Consecutive High Loss Interval, a sequence of small time intervals + contained in T, each with high frame loss ratio + Controller MEP The Controller MEP initiates SOAM PDUs, and receives responses + from the Responder MEP. + CoS Class of Service + DM Delay Measurement + Dual-Ended A type of process where a MEP sends measurement information to a peer + MEP that will perform the calculations. + EMS Element Management System + ETH-DM Ethernet Delay Measurement function + ETH-LM Ethernet Loss Measurement function + ETH-SLM Ethernet Synthetic Frame Loss Measurement function + EVC Ethernet Virtual Connection + FD Frame Delay + FDR Frame Delay Range + FLR Frame Loss Ratio + FM Fault Management + Forward OAM information sent from the Controller MEP to the Responder MEP. + For LM it indicates the frame counts/loss from the Controller MEP + to the Responder MEP. For DM is indicates the delay and delay + variation from the Controller MEP to the Responder MEP. + HLI High Loss Interval, a small time interval contained in T with a + high frame loss ratio + IEEE Institute of Electrical and Electronics Engineers + IETF Internet Engineering Task Force + IFDV Inter-Frame Delay Variation + ITU-T International Telecommunication Union - Telecommunication + Standardization Bureau + LAN Local Area Network + LM Loss Measurement + MAC Media Access Control + MA Maintenance Association (equivalent to a MEG) + MD Maintenance Domain (equivalent to a OAM Domain in MEF 17) + MD Level Maintenance Domain Level (equivalent to a MEG level) + ME Maintenance Entity + Measurement Bin A Measurement Bin is a counter that stores the number of + performance measurements falling within a specified range, during + a Measurement Interval + Measurement Interval A period of time during which measurements are taken. + Measurements initiated during one Measurement Interval are kept + separate from measurements taken during other Measurement Intervals. + It is important to note that this is different from T. + MEF Metro Ethernet Forum + MEG Maintenance Entity Group (equivalent to a MA) + MEG Level Maintenance Entity Group Level (equivalent to MD Level) + MEN Metro 963 Ethernet Network + MEP Maintenance Association End Point or MEG End Point + MFD Mean Frame Delay + MIB Management Information Base + MIP Maintenance Domain Intermediate Point or MEG Intermediate Point + MP Maintenance Point. One of either a MEP or a MIP + NE Network Element + NMS Network Management System + OAM Operations, Administration, and Maintenance + On-Demand OAM actions that are initiated via manual intervention for a limited + time to carry out diagnostics. On-Demand OAM can result in + singular or periodic OAM actions during the diagnostic time + interval + One-way A measurement performed in the forward or backward direction. For + example from MEP A to MEP B or from MEP B to MEP A. + OSS Operations Support System + PDU Protocol Data Unit + PM Performance Monitoring + PM Function A MEP capability specified for performance monitoring purposes + (e.g., Single-Ended Delay, Single-Ended Synthetic Loss) + PM Session A PM Session is the application of a given PM Function between a given + pair of MEPs and using a given CoS Frame Set over some (possibly + indefinite) period of time. + PM Solution A PM Solution is a set of related requirements that when implemented + allow a given set of performance metrics to be measured using a + given set of PM functions. + PM Tool A generic term used to discuss the application of a PM Function. + Proactive OAM actions that are carried on continuously to permit timely reporting + of fault and/or performance status. + Resiliency Performance The number of High Loss Intervals and Consecutive High + Loss Intervals in T + Responder MEP In a single-ended session, the Responder MEP receives SOAM PDUs, + from the Controller MEP, and transmits a response to the + Controller MEP. SOAM-PM + RFC Request for Comment + Service Frame An Ethernet frame transmitted across the UNI toward the Service + Provider or an Ethernet frame transmitted across the UNI toward + the Subscriber + Single-Ended A type of process where a MEP sends a measurement request and the + peer MEP replies with the requested information so the originating + MEP can calculate the measurement. + Sink MEP In a dual-ended session, the Sink MEP receives SOAM PDUs, from the + Controller MEP and performs the performance calculations. + SLM Synthetic Loss Measurement + SNMP Simple Network Management Protocol + SNMP Agent An SNMP entity containing one or more command responder and/or + notification originator applications (along with their associated + SNMP engine). Typically implemented in an NE. + SNMP Manager An SNMP entity containing one or more command generator and/or + notification receiver applications (along with their associated + SNMP engine). Typically implemented in an EMS or NMS. + SOAM Service OAM + SOAM PDU Service OAM frame, or Protocol Data Unit. Specifically, those PDUs + defined in [IEEE 802.1ag], [ITU-T Y.1731], or MEF specifications + Synthetic Traffic SOAM traffic that emulates service traffic in order to measure + the performance experience. Delay measurements must use synthetic + traffic, because user traffic does not contain standardized + timestamp fields. Other measurements, such as Frame Loss, may also + use synthetic frames for certain advantages (e.g., ability to + measure loss in multipoint services). + T Time Interval for SLS Metricss. The time over which a Performance + Metric is defined. T is at least as large as the Measurement + Interval, and generally consists of multiple Measurement + Intervals + TC Textual Conventions + TLV Type Length Value, a method of encoding Objects + Two-way A measurement of the performance of frames that flow from the + Controller MEP to Responder MEP and back again. + UML Unified Modeling Language + UTC Coordinated Universal Time + UNI User-to-Network Interface + VLAN Virtual LAN + + " + REVISION "201201131200Z" -- January 13, 2012 + DESCRIPTION + "Initial Version." + ::= { enterprises mef(15007) mefSoam(1) 3 } + +-- ***************************************************************************** +-- Object definitions in the SOAM PM MIB Module +-- ***************************************************************************** +mefSoamPmNotifications OBJECT IDENTIFIER ::= { mefSoamPmMib 0 } +mefSoamPmMibObjects OBJECT IDENTIFIER ::= { mefSoamPmMib 1 } +mefSoamPmMibConformance OBJECT IDENTIFIER ::= { mefSoamPmMib 2 } + +-- ***************************************************************************** +-- Groups in the SOAM PM MIB Module +-- ***************************************************************************** +mefSoamPmMep OBJECT IDENTIFIER ::= { mefSoamPmMibObjects 1 } +mefSoamPmLmObjects OBJECT IDENTIFIER ::= { mefSoamPmMibObjects 2 } +mefSoamPmDmObjects OBJECT IDENTIFIER ::= { mefSoamPmMibObjects 3 } +mefSoamPmNotificationCfg OBJECT IDENTIFIER ::= { mefSoamPmMibObjects 4 } +mefSoamPmNotificationObj OBJECT IDENTIFIER ::= { mefSoamPmMibObjects 5 } + + +-- ***************************************************************************** +-- Ethernet MEP Performance Monitoring Configuration +-- ***************************************************************************** + +mefSoamPmMepTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamPmMepEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table is an extension of the dot1agCfmMepTable and rows + are automatically added or deleted from this table based upon row + creation and destruction of the dot1agCfmMepTable. + + This table represents the local MEP PM configuration table. The + primary purpose of this table is provide local parameters for the + SOAM PM function found in [Y.1731] and [MEF SOAM-PM] and instantiated + at a MEP. + " + REFERENCE + "[Y.1731], [MEF SOAM-PM]" + ::= { mefSoamPmMep 1 } + +mefSoamPmMepEntry OBJECT-TYPE + SYNTAX MefSoamPmMepEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamPmMepTable." + AUGMENTS { + dot1agCfmMepEntry + } + ::= { mefSoamPmMepTable 1 } + +MefSoamPmMepEntry ::= SEQUENCE { + mefSoamPmMepOperNextIndex Dot1afCfmIndexIntegerNextFree, + mefSoamPmMepLmSingleEndedResponder TruthValue, + mefSoamPmMepSlmSingleEndedResponder TruthValue, + mefSoamPmMepDmSingleEndedResponder TruthValue + } + +mefSoamPmMepOperNextIndex OBJECT-TYPE + SYNTAX Dot1afCfmIndexIntegerNextFree + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains an unused value for a PM session number on a + MEP that can be used for either LM or DM sessions, or a zero to + indicate that none exist. This value needs to be read in order to + find an available index for row-creation of a PM session on a MEP and + then used when a row is created. This value is automatically updated + by the SNMP Agent after the row is created. + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never to be reused for other PM sessions on the same MEP while this + session is active, or until it wraps to zero. The index value keeps + increasing up to that time. This is to facilitate access control based + on a fixed index for an EMS, since the index is not reused. + + This object is an extension of the dot1agCfmMepTable and the object is + automatically added or deleted based upon row creation and destruction + of the dot1agCfmMepTable. + " + ::= { mefSoamPmMepEntry 1 } + +mefSoamPmMepLmSingleEndedResponder OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies whether the Loss Measurement (LMM) single-ended + Responder is enabled. + + The value 'true' indicates the single-ended Loss Measurement Responder + is enabled and if a LMM message is received a LMR will be sent in reply. + + The value 'false' indicates the single-ended Loss Measurement Responder + is disabled. If a LMM message is received no response will be sent and + the message will be discarded. + + This object needs to be persistent upon reboot or restart of a device. + + A MEP can be both a single-ended Responder and Controller simultaneously. + " + DEFVAL { true } + ::= { mefSoamPmMepEntry 2 } + +mefSoamPmMepSlmSingleEndedResponder OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies whether the Synthetic Loss Measurement (SLM) + single-ended Responder is enabled. + + The value 'true' indicates the single-ended SLM Responder is enabled and + if a SLM message is received a SLR will be sent in reply. + + The value 'false' indicates the single-ended SLM Responder is disabled. + If a SLM message is received no response will be sent and the message + will be discarded. + + This object needs to be persistent upon reboot or restart of a device. + + A MEP can be both a single-ended Responder and Controller simultaneously. + " + DEFVAL { true } + ::= { mefSoamPmMepEntry 3 } + +mefSoamPmMepDmSingleEndedResponder OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies whether the Delay Measurement (DMM) single + ended Responder is enabled. + + The value 'true' indicates the single-ended Delay Measurement Responder + is enabled and if a DMM message is received a DMR will be sent in reply. + + The value 'false' indicates the single-ended Delay Measurement Responder + is disabled. If a DMM message is received no response will be sent and + the message will be discarded. + + This object needs to be persistent upon reboot or restart of a device. + + A MEP can be both a single-ended Responder and Controller simultaneously. + " + DEFVAL { true } + ::= { mefSoamPmMepEntry 4 } + +-- ***************************************************************************** +-- Ethernet Loss Measurement Configuration Table +-- ***************************************************************************** + +mefSoamLmCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table includes configuration objects and operations for the + Frame Loss Measurement function defined in [Y.1731] and [MEF SOAM-PM]. + + Each row in the table represents a Loss Measurement session for + the defined MEP. This table uses four indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific LM session on the selected MEP. A + Loss Measurement session is created on an existing MEP by first + accessing the mefSoamPmMepOperNextIndex object and using this value as + the mefSoamLmCfgIndex in the row creation. + + Some writable objects in this table are only applicable in certain cases + (as described under each object), and attempts to write values for them + in other cases will be ignored. + + The writable objects in this table need to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R68; [Y.1731]" + ::= { mefSoamPmLmObjects 1 } + +mefSoamLmCfgEntry OBJECT-TYPE + SYNTAX MefSoamLmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmCfgTable." + INDEX { dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex + } + ::= { mefSoamLmCfgTable 1 } + +MefSoamLmCfgEntry ::= SEQUENCE { + mefSoamLmCfgIndex Unsigned32, + mefSoamLmCfgType INTEGER, + mefSoamLmCfgVersion Unsigned32, + mefSoamLmCfgEnabled TruthValue, + mefSoamLmCfgMeasurementEnable BITS, + mefSoamLmCfgMessagePeriod MefSoamTcMeasurementPeriodType, + + mefSoamLmCfgPriority IEEE8021PriorityValue, + mefSoamLmCfgFrameSize Unsigned32, + mefSoamLmCfgDataPattern MefSoamTcDataPatternType, + mefSoamLmCfgTestTlvIncluded TruthValue, + mefSoamLmCfgTestTlvPattern MefSoamTcTestPatternType, + mefSoamLmCfgMeasurementInterval Unsigned32, + mefSoamLmCfgNumIntervalsStored Unsigned32, + + mefSoamLmCfgDestMacAddress MacAddress, + mefSoamLmCfgDestMepId Dot1agCfmMepIdOrZero, + mefSoamLmCfgDestIsMepId TruthValue, + + mefSoamLmCfgStartTimeType MefSoamTcOperationTimeType, + mefSoamLmCfgFixedStartDateAndTime DateAndTime, + mefSoamLmCfgRelativeStartTime TimeInterval, + mefSoamLmCfgStopTimeType MefSoamTcOperationTimeType, + mefSoamLmCfgFixedStopDateAndTime DateAndTime, + mefSoamLmCfgRelativeStopTime TimeInterval, + mefSoamLmCfgRepetitionTime Unsigned32, + mefSoamLmCfgAlignMeasurementIntervals TruthValue, + mefSoamLmCfgAlignMeasurementOffset Unsigned32, + + mefSoamLmCfgAvailabilityMeasurementInterval Unsigned32, + mefSoamLmCfgAvailabilityNumConsecutiveMeasPdus Unsigned32, + mefSoamLmCfgAvailabilityFlrThreshold Unsigned32, + mefSoamLmCfgAvailabilityNumConsecutiveIntervals Unsigned32, + mefSoamLmCfgAvailabilityNumConsecutiveHighFlr Unsigned32, + + mefSoamLmCfgSessionType MefSoamTcSessionType, + mefSoamLmCfgSessionStatus MefSoamTcStatusType, + + mefSoamLmCfgHistoryClear TruthValue, + mefSoamLmCfgRowStatus RowStatus +} + +mefSoamLmCfgIndex +OBJECT-TYPE + SYNTAX Unsigned32(1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An index to the Loss Measurement Configuration table which indicates + the specific measurement session for the MEP. + + mefSoamPmMepOperNextIndex needs to be inspected to find an + available index for row-creation. + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never reused for other PM sessions on the same MEP while this + session is active. The index value keeps increasing until it + wraps to 0. This is to facilitate access control based + on a fixed index for an EMS, since the index is not reused. + " + ::= { mefSoamLmCfgEntry 1 } + +mefSoamLmCfgType OBJECT-TYPE + SYNTAX INTEGER { + lmLmm (1), + lmSlm (2), + lmCcm (3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies what type of Loss Measurement + will be performed. + + lmLmm(1) LMM SOAM PDU generated and received LMR responses tracked + lmSlm(2) SLM SOAM PDU generated and received SLR responses tracked + lmCcm(3) CCM SOAM PDU generated and received CCM PDUs tracked + + The lmSlm value is required. The lmLmm and lmCcm values are optional. + + The lmCcm loss measurement values are only valid for a point-to-point + MEG. Multipoint MEGs may give unreliable loss measurements. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[Y.1731] [MEF SOAM-PM] R51, R68, O7, R102" + DEFVAL { lmSlm } + ::= { mefSoamLmCfgEntry 2 } + +mefSoamLmCfgVersion OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates the version of the PDUs used to perform + Loss Measurement. + + The value is placed in the Version field of the PDU and indicates + that the PDU format used is the format defined in Y.1731 with + that version. + + The exact PDUs to use are specified by this object in combination with + mefSoamLmCfgType. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[Y.1731]" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 3 } + +mefSoamLmCfgEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies whether the Loss Measurement session + is enabled. + + The value 'true' indicates the Loss Measurement session is enabled and + SOAM PDUs are sent and/or measurements are collected when the session + is running according to the scheduling objects (start time, stop time, + etc.). + + The value 'false' indicates the Loss Measurement session is disabled + and SOAM PDUs are not sent and/or measurements collected. + + For a Loss Measurement session to be removed the row is + deleted in order to release internal resources. + + This object can written/modified after row creation time. + + If the LM session is enabled it resumes after shutdown/restart. + + If the LM session is disabled the current Measurement Interval is + stopped, if it in process at the time, and all the in process calculations + for the partially completed Measurement Interval are finalized. + + This object does not affect whether the single-ended Responder is + enabled or not, which is enabled or disabled by the + mefSoamPmMepLmSingleEndedResponder and + mefSoamPmMepSlmSingleEndedResponder objects. + " + REFERENCE + "[MEF SOAM-PM] R4, R5, R6, O1, R12, R14" + DEFVAL { true } + ::= { mefSoamLmCfgEntry 4 } + +mefSoamLmCfgMeasurementEnable OBJECT-TYPE + SYNTAX BITS { + bForwardTransmitedFrames(0), + bForwardReceivedFrames(1), + bForwardMinFlr(2), + bForwardMaxFlr(3), + bForwardAvgFlr(4), + bBackwardTransmitedFrames(5), + bBackwardReceivedFrames(6), + bBackwardMinFlr(7), + bBackwardMaxFlr(8), + bBackwardAvgFlr(9), + bSoamPdusSent(10), + bSoamPdusReceived (11), + + bAvailForwardHighLoss(12), + bAvailForwardConsecutiveHighLoss(13), + bAvailForwardAvailable(14), + bAvailForwardUnavailable(15), + bAvailForwardMinFlr(16), + bAvailForwardMaxFlr(17), + bAvailForwardAvgFlr(18), + + bAvailBackwardHighLoss(19), + bAvailBackwardConsecutiveHighLoss(20), + bAvailBackwardAvailable(21), + bAvailBackwardUnavailable(22), + bAvailBackwardMinFlr(23), + bAvailBackwardMaxFlr(24), + bAvailBackwardAvgFlr(25), + + bMeasuredStatsForwardMeasuredFlr(26), + bMeasuredStatsBackwardMeasuredFlr(27), + bMeasuredStatsAvailForwardStatus(28), + bMeasuredStatsAvailBackwardStatus(29) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A vector of bits that indicates the type of SOAM LM counters found + in the mefSoamLmMeasuredStatsTable, mefSoamLmCurrentStatsTable, + mefSoamLmHistoryStatsTable, mefSoamLmCurrentAvailStatsTable and + mefSoamLmHistoryAvailStatsTable that are enabled. + + A bit set to '1' enables the specific SOAM LM counter. A bit set to + '0' disables the SOAM LM counter. + + If a particular SOAM LM counter is not supported the BIT value is + set to '0'. + + Not all SOAM LM counters are supported for all SOAM LM types. + + This object can only be written at row creation time and cannot be + modified once it has been created. + + bForwardTransmitedFrames (0) + Enables/disables the mefSoamLmCurrentStatsForwardTransmittedFrames + and mefSoamLmHistoryStatsForwardTransmittedFrames counters. + bForwardReceivedFrames(1) + Enables/disables the mefSoamLmCurrentStatsForwardReceivedFrames + and mefSoamLmHistoryStatsForwardReceivedFrames counters. + bForwardMinFlr(2) + Enables/disables the mefSoamLmCurrentStatsForwardMinFlr + and mefSoamLmHistoryStatsForwardMinFlr counters. + bForwardMaxFlr(3) + Enables/disables the mefSoamLmCurrentStatsForwardMaxFlr + and mefSoamLmHistoryStatsForwardMaxFlr counters. + bForwardAvgFlr(4) + Enables/disables the mefSoamLmCurrentStatsForwardAvgFlr + and mefSoamLmHistoryStatsForwardAvgFlr counters. + bBackwardTransmitedFrames(5) + Enables/disables the mefSoamLmCurrentStatsBackwardTransmittedFrames + and mefSoamLmHistoryStatsBackwardTransmittedFrames counters. + bBackwardReceivedFrames(6) + Enables/disables the mefSoamLmCurrentStatsBackwardReceivedFrames + and mefSoamLmHistoryStatsBackwardReceivedFrames counters. + bBackwardMinFlr(7) + Enables/disables the mefSoamLmCurrentStatsBackwardMinFlr + and mefSoamLmHistoryStatsBackwardMinFlr counters. + bBackwardMaxFlr(8) + Enables/disables the mefSoamLmCurrentStatsBackwardMaxFlr + and mefSoamLmHistoryStatsBackwardMaxFlr counters. + bBackwardAvgFlr(9) + Enables/disables the mefSoamLmCurrentStatsBackwardAvgFlr + and mefSoamLmHistoryStatsBackwardAvgFlr counters. + bSoamPdusSent (10) + Enables/disables the mefSoamLmCurrentStatsSoamPdusSent + and mefSoamLmHistoryStatsSoamPdusSent counters. + bSoamPdusReceivedbReceivedMeasurements (11) + Enables/disables the mefSoamLmCurrentStatsSoamPdusReceived + and mefSoamLmHistoryStatsSoamPdusReceived counters. + + bAvailForwardHighLoss(12) + Enables/disables the mefSoamLmCurrentAvailStatsForwardHighLoss + and mefSoamLmHistoryAvailStatsForwardHighLoss counters. + bAvailForwardConsecutiveHighLoss(13) + Enables/disables the mefSoamLmCurrentAvailStatsForwardConsecutiveHighLoss + and mefSoamLmHistoryAvailStatsForwardConsecutiveHighLoss counters. + bAvailForwardAvailable(14) + Enables/disables the mefSoamLmCurrentAvailStatsForwardAvailable + and mefSoamLmHistoryAvailStatsForwardAvailable counters. + bAvailForwardUnavailable(15) + Enables/disables the mefSoamLmCurrentAvailStatsForwardUnavailable + and mefSoamLmHistoryAvailStatsForwardUnavailable counters. + bAvailForwardMinFlr(16) + Enables/disables the mefSoamLmCurrentAvailStatsForwardMinFlr + and mefSoamLmHistoryAvailStatsForwardMinFlr counters. + bAvailForwardMaxFlr(17) + Enables/disables the mefSoamLmCurrentAvailStatsForwardMaxFlr + and mefSoamLmHistoryAvailStatsForwardMaxFlr counters. + bAvailForwardAvgFlr(18) + Enables/disables the mefSoamLmCurrentAvailStatsForwardAvgFlr + and mefSoamLmHistoryAvailStatsForwardAvgFlr counters. + + bAvailBackwardHighLoss(19) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardHighLoss + and mefSoamLmHistoryAvailStatsBackwardHighLoss counters. + bAvailBackwardConsecutiveHighLoss(20) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardConsecutiveHighLoss + and mefSoamLmHistoryAvailStatsBackwardConsecutiveHighLoss counters. + bAvailBackwardAvailable(21) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardAvailable + and mefSoamLmHistoryAvailStatsBackwardAvailable counters. + bAvailBackwardUnavailable(22) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardUnavailable + and mefSoamLmHistoryAvailStatsBackwardUnavailable counters. + bAvailBackwardMinFlr(23) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardMinFlr + and mefSoamLmHistoryAvailStatsBackwardMinFlr counters. + bAvailBackwardMaxFlr(24) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardMaxFlr + and mefSoamLmHistoryAvailStatsBackwardMaxFlr counters. + bAvailBackwardAvgFlr(25) + Enables/disables the mefSoamLmCurrentAvailStatsBackwardAvgFlr + and mefSoamLmHistoryAvailStatsBackwardAvgFlr counters. + + bMeasuredStatsForwardMeasuredFlr(26) + Enables/disables the mefSoamLmMeasuredStatsForwardFlr counter. + bMeasuredStatsBackwardMeasuredFlr(27) + Enables/disables the mefSoamLmMeasuredStatsBackwardFlr counter. + bMeasuredStatsAvailForwardStatus(28) + Enables/disables the mefSoamLmMeasuredStatsAvailForwardStatus counter. + bMeasuredStatsAvailBackwardStatus(29) + Enables/disables the mefSoamLmMeasuredStatsAvailBackwardStatus counter. + " + REFERENCE + "[Y.1731]" + DEFVAL { { } } + ::= { mefSoamLmCfgEntry 5 } + +mefSoamLmCfgMessagePeriod OBJECT-TYPE + SYNTAX MefSoamTcMeasurementPeriodType + UNITS "ms" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the interval between Loss Measurement + OAM message transmission. For Loss Measurement monitoring + applications the default value is 1 sec. + + This object is not applicable if mefSoamLmCfgType is set to lmCcm + and is ignored for that Loss Measurement Type. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R76, R77, D29, D30" + DEFVAL { 1000 } + ::= { mefSoamLmCfgEntry 6 } + +mefSoamLmCfgPriority OBJECT-TYPE + SYNTAX IEEE8021PriorityValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the Loss Measurement OAM message priority + as well as the priority of the service/OAM traffic to be monitored. + Only frames of the same Class of Service are counted. + + The default value is to be the value which yields the lowest frame + loss. + + This object is not applicable if mefSoamLmCfgType is set to lmCcm. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R1, R2, R71, D28, R72, R73, R105-R109, D45; + [MEF 10.2.1] Section 6.8" + ::= { mefSoamLmCfgEntry 7 } + +mefSoamLmCfgFrameSize OBJECT-TYPE + SYNTAX Unsigned32 (64..9600) + UNITS "bytes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the Loss Measurement frame size between + 64 bytes and the maximum transmission unit of the EVC. + + The range of frame sizes from 64 through 2000 octets need to be + supported, and the range of frame sizes from 2001 through 9600 octets + is suggested be supported. + + The adjustment to the frame size of the standard frame size is + accomplished by the addition of a Data or Test TLV. A Data or Test TLV + is only added to the frame if the frame size is greater than 64 bytes. + + This object is only valid for the entity transmitting the Loss + Measurement frames, type 'lmSlm', and is ignored by the + entity receiving frames. It is not applicable for the 'lmCcm' or + 'lmLmm' types. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R78, R79, D31, D32 [Y.1731]" + DEFVAL { 64 } + ::= { mefSoamLmCfgEntry 8 } + +mefSoamLmCfgDataPattern OBJECT-TYPE + SYNTAX MefSoamTcDataPatternType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the LM data pattern included in a Data TLV + when the size of the LM frame is determined by the + mefSoamLmFrameSize object and mefSoamLmTestTlvIncluded is 'false'. + + If the frame size object does not define the LM frame size or + mefSoamLmTestTlvIncluded is 'true' the value of this object is + ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + DEFVAL { zeroPattern } + ::= { mefSoamLmCfgEntry 9 } + +mefSoamLmCfgTestTlvIncluded OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Indicates whether a Test TLV or Data TLV is included when the size + of the LM frame is determined by the mefSoamLmFrameSize object. + + A value of 'true' indicates that the Test TLV is to be included. A + value of 'false' indicates that the Data TLV is to be included. + + If the frame size object does not define the LM frame size + the value of this object is ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[Y.1731] 9.3" + DEFVAL { false } + ::= { mefSoamLmCfgEntry 10 } + +mefSoamLmCfgTestTlvPattern OBJECT-TYPE + SYNTAX MefSoamTcTestPatternType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of test pattern to be + sent in the LM frame Test TLV when the size of LM PDU is + determined by the mefSoamLmFrameSize object and + mefSoamLmTestTlvIncluded is 'true'. If the frame size object + does not define the LM frame size or mefSoamLmTestTlvIncluded + is 'false' the value of this object is ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + DEFVAL { null } + ::= { mefSoamLmCfgEntry 11 } + +mefSoamLmCfgMeasurementInterval OBJECT-TYPE + SYNTAX Unsigned32 (1..525600) + UNITS "minutes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the Measurement Interval for FLR statistics, in minutes. + + A Measurement Interval of 15 minutes needs to be supported, other intervals + may be supported. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R16, R17, R110, R111, D46" + DEFVAL { 15 } + ::= { mefSoamLmCfgEntry 12 } + +mefSoamLmCfgNumIntervalsStored OBJECT-TYPE + SYNTAX Unsigned32 (2..1000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the number of completed Measurement Intervals + to store in the history statistic table (mefSoamLmHistoryStatsTable) + and the history availability statistic table + (mefSoamLmHistoryAvailStatsTable). + + At least 32 completed Measurement Intervals need to be stored. 96 + Measurement Intervals are recommended to be stored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R21, D8, D9" + DEFVAL { 32 } + ::= { mefSoamLmCfgEntry 13 } + +mefSoamLmCfgDestMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Target or Destination MAC Address Field to be transmitted. + + If mefSoamLmCfgType is 'lmCcm', the destination MAC address is always a + multicast address indicating the level of the MEG: 01-80-c2-00-00-3y, + where y is the level of the MEG. An error is returned if this object + is set to any other value. + + If mefSoamLmCfgType is 'lmLmm' or 'lmSlm', the destination address is + the unicast address of the destination MEP. An error is returned if + this object is set to a multicast address. + + This address will be used if the value of the object + mefSoamLmDestIsMepId is 'false'. + + This object is only valid for the entity transmitting the + SOAM LM frames and is ignored by the entity receiving + SOAM LM frames. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R70, R104" + ::= { mefSoamLmCfgEntry 14 } + +mefSoamLmCfgDestMepId OBJECT-TYPE + SYNTAX Dot1agCfmMepIdOrZero + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Maintenance Association End Point Identifier of + another MEP in the same Maintenance Association to which + the SOAM LM frame is to be sent. + + This address will be used if the value of the column + mefSoamLmDestIsMepId is 'true'. A value of zero + means that the destination MEP ID has not been configured. + + This object is only valid for the entity transmitting the Loss + Measurement frames, types 'lmLmm' and 'lmSlm'. It is not applicable for + the 'lmCcm' type. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R70, R104" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 15 } + +mefSoamLmCfgDestIsMepId OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A value of 'true' indicates that MEPID of the target MEP is used for + SOAM LM frame transmission. + + A value of 'false' indicates that the MAC address of the + target MEP is used for SOAM LM frame transmission. + + This object is only valid for the entity transmitting the Loss + Measurement frames, types 'lmLmm' and 'lmSlm'. It is not applicable for + the 'lmCcm' type. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R70, R104" + DEFVAL { true } + ::= { mefSoamLmCfgEntry 16 } + +mefSoamLmCfgStartTimeType OBJECT-TYPE + SYNTAX MefSoamTcOperationTimeType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of start time of the SOAM LM + session. The start time can be disabled (none), immediate, relative, + or fixed. + + The value of 'none' is illegal and a write error will be returned + if this value is used. + + The value of 'immediate' starts the SOAM LM session when the + mefSoamLmCfgEnabled is true. + + The value of 'fixed' starts the SOAM LM session when the + mefSoamLmFixedStartDateAndTime is less than or equal to the current + system date and time and mefSoamLmCfgEnabled is true. This value is used + to implement an On-Demand fixed time PM session. + + The value of 'relative' starts the SOAM LM session when the current + system date and time minus the mefSoamLmRelativeStartTime is greater + than or equal to the system date and time when the mefSoamLmStartTimeType + object was written and mefSoamLmCfgEnabled is true. This value is used + to implement an On-Demand relative time PM session. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3, R7, R8, D1" + DEFVAL { immediate } + ::= { mefSoamLmCfgEntry 17 } + +mefSoamLmCfgFixedStartDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the fixed start date/time for the + SOAM Loss Measurement session. This object is used only used if + mefSoamLmStartTimeType is 'fixed' and is ignored otherwise. + + The default value is year 0000, month 01, day 01, time 00:00:00.00. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R9" + DEFVAL { '0000010100000000'H } + ::= { mefSoamLmCfgEntry 18 } + +mefSoamLmCfgRelativeStartTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the relative start time, from the + current system time, for the SOAM LM session. This + object is used only if mefSoamLmStartTimeType is 'relative' and is + ignored otherwise. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R9" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 19 } + +mefSoamLmCfgStopTimeType OBJECT-TYPE + SYNTAX MefSoamTcOperationTimeType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of stop time to terminate the + SOAM LM session. The stop time can be forever (none), relative, or + fixed. + + The value of 'none' indicates that the SOAM LM session never ends once it + has started unless it the session is disabled. + + The value of 'immediate' is illegal and a write error will be returned + if this value is used. + + The value of 'fixed' stops the SOAM LM session when the + mefSoamLmFixedStopDateAndTime is less than or equal + to the current system date and time. This + value is used to implement an On-Demand fixed time PM session. + + The value of 'relative' stops the SOAM LM session when the time + indicated by mefSoamLmRelativeStopTime has passed since the session + start time as determined by the mefSoamLmCfgStartTimeType, + mefSoamLmCfgFixedStartDateAndTime and mefSoamLmCfgRelativeStartTime + objects. This value is used to implement an On-Demand relative time + PM session. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3, R10, D2" + DEFVAL { none } + ::= { mefSoamLmCfgEntry 20 } + +mefSoamLmCfgFixedStopDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the fixed stop date/time for the + SOAM Loss Measurement session. This object is used only used + if mefSoamLmStopTimeType is 'fixed' and is ignored otherwise. + + The default value is year 0000, month 01, day 01, time 00:00:00.00. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R10, R13" + DEFVAL { '0000010100000000'H } + ::= { mefSoamLmCfgEntry 21 } + +mefSoamLmCfgRelativeStopTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the relative stop time, from the + session start time, to stop the SOAM LM session. This + object is used only if mefSoamLmStopTimeType is 'relative' and is + ignored otherwise. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R11" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 22 } + +mefSoamLmCfgRepetitionTime OBJECT-TYPE + SYNTAX Unsigned32 (0..31536000) + UNITS "seconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable repetition time between + Measurement Intervals in a Loss Measurement session, in seconds. + + If the value is 0 (none), there is no time gap between the end of one + Measurement Interval and the start of a new Measurement Interval. + This is the normal usage case. + + If the value is greater than 0 but less than or equal to the measurement + interval, an error is returned. + + If the value is greater than one Measurement Interval there is time gap + between the end of one Measurement Interval and the start of the next + Measurement Interval. The repetition time specifies the time between + the start of consecutive Measurement Intervals; hence the gap between + the end of one Measurement Interval and the start of the next is equal + to the difference between the repetition time and the measurement + interval. During this gap, no SOAM PDUs are sent for this session and + no measurements are made. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R18, D3, R19, R20" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 23 } + +mefSoamLmCfgAlignMeasurementIntervals OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies whether the Measurement Intervals for + the Loss Measurement session are aligned with a zero offset to + real time. + + The value 'true' indicates that each Measurement Interval starts + at a time which is aligned to NE time source hour, if the repetition + time (or the Measurement Interval, if the repetition time is 0) is + a factor of an hour, i.e. 60min/15min = 4. For instance, a + Measurement Interval/repetition time of 15 minutes would stop/start + the Measurement Interval at 0, 15, 30, and 45 minutes of an hour. A + Measurement Interval/Repetition Time of 7 minutes would not align + to the hour since 7 minutes is NOT a factor of an hour, i.e. + 60min/7min = 8.6. In this case the behavior is the same as if the + object is set to 'false'. + + The value 'false' indicates that the first Measurement Interval starts + at an arbitrary time and each subsequent Measurement Interval starts + at a time which is determined by mefSoamLmCfgRepetitionTime. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] D4, D5, D6" + DEFVAL { true } + ::= { mefSoamLmCfgEntry 24 } + +mefSoamLmCfgAlignMeasurementOffset OBJECT-TYPE + SYNTAX Unsigned32 (0..525600) + UNITS "minutes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the offset in minutes from the time of day value + if mefSoamLmCfgAlignMeasurementIntervals is 'true' and the repetition + time is a factor of 60 minutes. If not, the value of this object + is ignored. + + If the Measurement Interval is 15 minutes and + mefSoamLmCfgAlignMeasurementIntervals is true and if this object was + set to 5 minutes, the Measurement Intervals would start at 5, 20, 35, 50 + minutes past each hour. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] D7" + DEFVAL { 0 } + ::= { mefSoamLmCfgEntry 25 } + +mefSoamLmCfgAvailabilityMeasurementInterval OBJECT-TYPE + SYNTAX Unsigned32 (1..525600) + UNITS "minutes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the availability Measurement Interval in + minutes. + + A Measurement Interval of 15 minutes is to be supported, other intervals + can be supported. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R16, R17" + DEFVAL { 15 } + ::= { mefSoamLmCfgEntry 26 } + +mefSoamLmCfgAvailabilityNumConsecutiveMeasPdus OBJECT-TYPE + SYNTAX Unsigned32 (1..1000000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable number of consecutive + loss measurement PDUs to be used in evaluating the + availability/unavailability status of each availability + indicator per MEF 10.2.1. Loss Measurement PDUs (LMMs, CCMs or + SLMs) are sent regularly with a period defined by + mefSoamLmCfgMessagePeriod. Therefore, this object, when + multiplied by mefSoamLmCfgMessagePeriod, is equivalent to + the Availability parameter of 'delta_t' as specified by MEF 10.2.1. + + If the mefSoamLmCfgType is lmLMM or lmCCM, this object defines the + number of LMM or CCM PDUs transmitted during each 'delta_t' period. + The Availability flr for a given 'delta_t' can be calculated based + on the counters in the last LMM/R or CCM during this 'delta_t' and + the last LMM/R or CCM in the previous 'delta_t'. + + If the mefSoamLmCfgType is lmSLM, this object defines the number + of SLM PDUs transmitted during each 'delta_t' period. The + Availability flr for a given 'delta_t' is calculated based on the + number of those SLM PDUs that are lost. + + If the mefSoamLmCfgType is lmLMM or lmCCM, the number range of 1 + through 10 must be supported. The number range of 10 through 1000000 + may be supported, but is not mandatory. + + If the mefSoamLmCfgType is lmSLM, the number range of 10 through + 100 must be supported. The number range of 100 through 1000000 + may be supported, but is not mandatory. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF 10.2.1] Section 7.9.8; [MEF SOAM-PM] R80, D33, R81" + DEFVAL { 10 } + ::= { mefSoamLmCfgEntry 27 } + +mefSoamLmCfgAvailabilityFlrThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable availability threshold to be + used in evaluating the availability/unavailability status of an + availability indicator per MEF 10.2.1. The availability threshold range + of 0.00 (0) through 1.00 (100000) is supported. This parameter is + equivalent to the Availability parameter of 'C' as specified by + MEF 10.2.1. + + Units are in milli-percent, where 1 indicates 0.001 percent. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF 10.2.1] Section 7.9.8; [MEF SOAM-PM] R81, R82, D34" + DEFVAL { 50000 } + ::= { mefSoamLmCfgEntry 28 } + +mefSoamLmCfgAvailabilityNumConsecutiveIntervals OBJECT-TYPE + SYNTAX Unsigned32 (1..1000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable number of consecutive + availability indicators to be used to determine a change in the + availability status as indicated by MEF 10.2.1. This parameter is + equivalent to the Availability parameter of 'n' as specified + by MEF 10.2.1. + + The number range of 1 through 10 must be supported. The number range + of 1 through 1000 may be supported, but is not mandatory. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF 10.2.1] Section 7.9.8; [MEF SOAM-PM] R80, D33" + DEFVAL { 10 } + ::= { mefSoamLmCfgEntry 29 } + +mefSoamLmCfgAvailabilityNumConsecutiveHighFlr OBJECT-TYPE + SYNTAX Unsigned32 (1..1000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable number of consecutive + availability indicators to be used for assessing CHLI. This + parameter is equivalent to the Resilency parameter of 'p' as + specified by MEF 10.2.1. + + mefSoamLmCfgAvailabilityNumConsecutiveHighFlr must be strictly less than + mefSoamLmCfgAvailabilityNumConsecutiveIntervals. If not, the count of high + loss intervals over time, mefSoamLmAvailabilityHighLoss, and the count + of consecutive high loss levels, mefSoamLmAvailabilityConsecutiveHighLoss, + is disabled. + + The number range of 1 through 10 must be supported. The number range + of 1 through 1000 may be supported, but is not mandatory. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF 10.2.1] Section 7.9.8; [MEF SOAM-PM] R86, D35, D36" + DEFVAL { 5 } + ::= { mefSoamLmCfgEntry 30 } + +mefSoamLmCfgSessionType OBJECT-TYPE + SYNTAX MefSoamTcSessionType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates whether the current session is defined to + be 'Proactive' or 'On-Demand'. A value of 'proactive' + indicates the current session is 'Proactive'. A value of 'onDemand' + indicates the current session is 'On-Demand'. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3" + DEFVAL { proactive } + ::= { mefSoamLmCfgEntry 31 } + +mefSoamLmCfgSessionStatus OBJECT-TYPE + SYNTAX MefSoamTcStatusType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the current status of the LM session. A value + of 'active' indicates the current LM session is active, i.e. the current + time lies between the start time and the stop time, and + mefSoamLmCfgEnabled is true. A value of 'notActive' indicates the + current LM session is not active, i.e. it has not started yet, has + stopped upon reaching the stop time, or is disabled. + " + ::= { mefSoamLmCfgEntry 32 } + +mefSoamLmCfgHistoryClear OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object when written clears the Loss Measurement history + Table (mefSoamLmHistoryStatsTable) - all rows are deleted. + When read the value always returns 'false'. + + Writing this value does not change the current stat table, + nor any of the items in the configuration table. + Writing this value during row creation has no effect. + " + DEFVAL { false } + ::= { mefSoamLmCfgEntry 33 } + +mefSoamLmCfgRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of the row. + + The writable columns in a row cannot be changed if the row + is active, except for mefSoamLmCfgHistoryClear and mefSoamLmCfgEnabled + objects. All columns must have a valid value before a row + can be activated. + " + ::= { mefSoamLmCfgEntry 34 } + +-- ***************************************************************************** +-- Ethernet Loss Measurement Measured Statistic Table +-- ***************************************************************************** + +mefSoamLmMeasuredStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmMeasuredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object contains the last measured results for a SOAM Loss + Measurement session. + + Each row in the table represents a Loss Measurement session for + the defined MEP. This table uses four indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific LM session on the selected MEP. + + Instances of this managed object are created automatically + by the SNMP Agent when the Loss Measurement session is running. + + Each object in this table applies only if the corresponding bit is set in + mefSoamLmCfgMeasurementEnable. + + The objects in this table do not need to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, 8D18" + ::= { mefSoamPmLmObjects 2 } + +mefSoamLmMeasuredStatsEntry OBJECT-TYPE + SYNTAX MefSoamLmMeasuredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmMeasuredStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex + } + ::= { mefSoamLmMeasuredStatsTable 1 } + +MefSoamLmMeasuredStatsEntry ::= SEQUENCE { + mefSoamLmMeasuredStatsForwardFlr Unsigned32, + mefSoamLmMeasuredStatsBackwardFlr Unsigned32, + mefSoamLmMeasuredStatsAvailForwardStatus MefSoamTcAvailabilityType, + mefSoamLmMeasuredStatsAvailBackwardStatus MefSoamTcAvailabilityType, + mefSoamLmMeasuredStatsAvailForwardLastTransitionTime DateAndTime, + mefSoamLmMeasuredStatsAvailBackwardLastTransitionTime DateAndTime +} + +mefSoamLmMeasuredStatsForwardFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the last frame loss ratio in the forward direction + calculated by this MEP. The FLR value + is a ratio that is expressed as a percent with a value of 0 (ratio + 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmMeasuredStatsEntry 1 } + +mefSoamLmMeasuredStatsBackwardFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the last frame loss ratio in the backward direction + calculated by this MEP. The FLR value + is a ratio that is expressed as a percent with a value of 0 (ratio + 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmMeasuredStatsEntry 2 } + +mefSoamLmMeasuredStatsAvailForwardStatus OBJECT-TYPE + SYNTAX MefSoamTcAvailabilityType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the availability status (the outcome of the + last known availability indicator) in the forward direction. + Note that the status of an availability indicator is not known until + the loss for a number of subsequent availability indicators has been + calculated (as determined by + mefSoamLmCfgAvailabilityNumConsecutiveIntervals) + " + REFERENCE + "[MEF SOAM-PM] R83" + ::= { mefSoamLmMeasuredStatsEntry 3 } + +mefSoamLmMeasuredStatsAvailBackwardStatus OBJECT-TYPE + SYNTAX MefSoamTcAvailabilityType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the availability status (the outcome of the + last availability indicator) in the backward direction. + Note that the status of an availability indicator is not known until + the loss for a number of subsequent availability indicators has been + calculated (as determined by + mefSoamLmCfgAvailabilityNumConsecutiveIntervals) + " + REFERENCE + "[MEF SOAM-PM] R83" + ::= { mefSoamLmMeasuredStatsEntry 4 } + +mefSoamLmMeasuredStatsAvailForwardLastTransitionTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the time of the last transition + between available and unavailable in the forward direction. + + If there have been no transitions since the Loss Measurement + Session was started, this is set to 0. + " + REFERENCE + "[MEF SOAM-PM] R83" + ::= { mefSoamLmMeasuredStatsEntry 5 } + +mefSoamLmMeasuredStatsAvailBackwardLastTransitionTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the time of the last transition + between available and unavailable in the backward direction. + + If there have been no transitions since the Loss Measurement + Session was started, this is set to 0. + " + REFERENCE + "[MEF SOAM-PM] R83" + ::= { mefSoamLmMeasuredStatsEntry 6 } + + +-- ***************************************************************************** +-- Ethernet Loss Measurement Current Availability Statistic Table +-- ***************************************************************************** + +mefSoamLmCurrentAvailStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmCurrentAvailStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object contains the current results for a SOAM Loss Measurement + session for availability statistics gathered during the interval + indicated by mefSoamLmCfgAvailabilityMeasurementInterval. + + Each row in the table represents a Loss Measurement session for + the defined MEP. This table uses four indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific LM session on the selected MEP. + + Instances of this managed object are created automatically + by the SNMP Agent when the Loss Measurement session is running. + + The objects in this table apply regardless of the value of + mefSoamLmCfgType unless otherwise specified in the object description. + + Except for mefSoamLmCurrentAvailStatsIndex, + mefSoamLmCurrentAvailStatsStartTime, mefSoamLmCurrentAvailStatsElapsedTime + and mefSoamLmCurrentAvailStatsSuspect, each object in this table applies + only if the corresponding bit is set in mefSoamLmCfgMeasurementEnable. + + The objects in this table may be persistent upon reboot or restart + of a device. + " + REFERENCE + "[MEF SOAM-PM] D9, D18" + ::= { mefSoamPmLmObjects 3 } + +mefSoamLmCurrentAvailStatsEntry OBJECT-TYPE + SYNTAX MefSoamLmCurrentAvailStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmCurrentAvailStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex + } + ::= { mefSoamLmCurrentAvailStatsTable 1 } + +MefSoamLmCurrentAvailStatsEntry ::= SEQUENCE { + mefSoamLmCurrentAvailStatsIndex Unsigned32, + mefSoamLmCurrentAvailStatsStartTime DateAndTime, + mefSoamLmCurrentAvailStatsElapsedTime TimeInterval, + mefSoamLmCurrentAvailStatsSuspect TruthValue, + + mefSoamLmCurrentAvailStatsForwardHighLoss Unsigned32, + mefSoamLmCurrentAvailStatsBackwardHighLoss Unsigned32, + mefSoamLmCurrentAvailStatsForwardConsecutiveHighLoss Unsigned32, + mefSoamLmCurrentAvailStatsBackwardConsecutiveHighLoss Unsigned32, + + mefSoamLmCurrentAvailStatsForwardAvailable Gauge32, + mefSoamLmCurrentAvailStatsBackwardAvailable Gauge32, + mefSoamLmCurrentAvailStatsForwardUnavailable Gauge32, + mefSoamLmCurrentAvailStatsBackwardUnavailable Gauge32, + mefSoamLmCurrentAvailStatsForwardMinFlr Unsigned32, + mefSoamLmCurrentAvailStatsForwardMaxFlr Unsigned32, + mefSoamLmCurrentAvailStatsForwardAvgFlr Unsigned32, + mefSoamLmCurrentAvailStatsBackwardMinFlr Unsigned32, + mefSoamLmCurrentAvailStatsBackwardMaxFlr Unsigned32, + mefSoamLmCurrentAvailStatsBackwardAvgFlr Unsigned32 +} + +mefSoamLmCurrentAvailStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index for the current availability Measurement Interval for this + PM session. This value will become the value for + mefSoamLmHistoryAvailStatsIndex once the Measurement Interval + is completed. The duration of the Measurement Interval is specified + by mefSoamLmCfgAvailabilityMeasurementInterval. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. + " + ::= { mefSoamLmCurrentAvailStatsEntry 1 } + +mefSoamLmCurrentAvailStatsStartTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval started. + " + REFERENCE + "[MEF SOAM-PM] R87, R112" + ::= { mefSoamLmCurrentAvailStatsEntry 2 } + +mefSoamLmCurrentAvailStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval has been running, in 0.01 + seconds. + " + REFERENCE + "[MEF SOAM-PM] R24, R87, R112" + ::= { mefSoamLmCurrentAvailStatsEntry 3 } + +mefSoamLmCurrentAvailStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is set to false at the start of a measurement + interval. It is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service + " + REFERENCE + "[MEF SOAM-PM] R39, R40, R41" + ::= { mefSoamLmCurrentAvailStatsEntry 4 } + +mefSoamLmCurrentAvailStatsForwardHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of high loss intervals (HLI) over + time in the forward direction. + + The value starts at 0 and increments for every HLI that occurs. + This parameter is equivalent to 'L Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 5 } + +mefSoamLmCurrentAvailStatsBackwardHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of high loss intervals (HLI) over + time in the backwards direction. + + The value starts at 0 and increments for every HLI that occurs. + This parameter is equivalent to 'L Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 6 } + +mefSoamLmCurrentAvailStatsForwardConsecutiveHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of consecutive high loss intervals + (CHLI) over time in the forward direction. + + The value starts at 0 and increments for every HLI that occurs + that is determined to fall within a CHLI. + This parameter is equivalent to 'B Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 7 } + +mefSoamLmCurrentAvailStatsBackwardConsecutiveHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of consecutive high loss intervals + (CHLI) over time in the backward direction. + + The value starts at 0 and increments for every HLI that occurs + that is determined to fall within a CHLI. + This parameter is equivalent to 'B Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 8 } + +mefSoamLmCurrentAvailStatsForwardAvailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as available in the forward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87; [MEF 10.2.1]" + ::= { mefSoamLmCurrentAvailStatsEntry 9 } + +mefSoamLmCurrentAvailStatsBackwardAvailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as available in the backward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 10 } + +mefSoamLmCurrentAvailStatsForwardUnavailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as unavailable in the forward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 11 } + +mefSoamLmCurrentAvailStatsBackwardUnavailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as unavailable in the backward direction by this MEP + during this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmCurrentAvailStatsEntry 12 } + +mefSoamLmCurrentAvailStatsForwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 13 } + +mefSoamLmCurrentAvailStatsForwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 14 } + +mefSoamLmCurrentAvailStatsForwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 15 } + +mefSoamLmCurrentAvailStatsBackwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 16 } + +mefSoamLmCurrentAvailStatsBackwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed + as a percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 17 } + +mefSoamLmCurrentAvailStatsBackwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentAvailStatsEntry 18 } + +-- ***************************************************************************** +-- Ethernet Loss Measurement Current Statistic Table +-- ***************************************************************************** + +mefSoamLmCurrentStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmCurrentStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the results for the current Measurement + Interval in a SOAM Loss Measurement session gathered during the interval + indicated by mefSoamLmCfgMeasurementInterval. + + A row in this table is created automatically + by the SNMP Agent when the Loss Measurement session is configured. + + Each row in the table represents the current statistics for a Loss + Measurement session for the defined MEP. This table uses four indices. + The first three indices are the indices of the Maintenance Domain, MaNet, + and MEP tables. The fourth index is the specific LM session on the + selected MEP. There may be more than one LM session per MEP. The + main use case for this is to allow multiple CoS instances to be + operating simultaneously for a MEP. + + The objects in this table apply regardless of the value of + mefSoamLmCfgType unless otherwise specified in the object description. + + Except for mefSoamLmCurrentStatsIndex, mefSoamLmCurrentStatsStartTime, + mefSoamLmCurrentStatsElapsedTime and mefSoamLmCurrentStatsSuspect, + each object in this table applies only if the corresponding bit is set in + mefSoamLmCfgMeasurementEnable. + + The objects in this table do not need to be persistent upon reboot or + restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, D9, D18" + ::= { mefSoamPmLmObjects 4 } + +mefSoamLmCurrentStatsEntry OBJECT-TYPE + SYNTAX MefSoamLmCurrentStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmCurrentStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex + } + ::= { mefSoamLmCurrentStatsTable 1 } + +MefSoamLmCurrentStatsEntry ::= SEQUENCE { + mefSoamLmCurrentStatsIndex Unsigned32, + mefSoamLmCurrentStatsStartTime DateAndTime, + mefSoamLmCurrentStatsElapsedTime TimeInterval, + mefSoamLmCurrentStatsSuspect TruthValue, + mefSoamLmCurrentStatsForwardTransmittedFrames Gauge32, + mefSoamLmCurrentStatsForwardReceivedFrames Gauge32, + mefSoamLmCurrentStatsForwardMinFlr Unsigned32, + mefSoamLmCurrentStatsForwardMaxFlr Unsigned32, + mefSoamLmCurrentStatsForwardAvgFlr Unsigned32, + mefSoamLmCurrentStatsBackwardTransmittedFrames Gauge32, + mefSoamLmCurrentStatsBackwardReceivedFrames Gauge32, + mefSoamLmCurrentStatsBackwardMinFlr Unsigned32, + mefSoamLmCurrentStatsBackwardMaxFlr Unsigned32, + mefSoamLmCurrentStatsBackwardAvgFlr Unsigned32, + mefSoamLmCurrentStatsSoamPdusSent Gauge32, + mefSoamLmCurrentStatsSoamPdusReceived Gauge32 +} + +mefSoamLmCurrentStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index for the current Measurement Interval for this + PM session. This value will become the value for + mefSoamLmHistoryStatsIndex once the Measurement Interval + is completed. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. + " + ::= { mefSoamLmCurrentStatsEntry 1 } + +mefSoamLmCurrentStatsStartTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval started. + " + REFERENCE + "[MEF SOAM-PM] R22, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 2 } + +mefSoamLmCurrentStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval has been running, in 0.01 + seconds. + " + REFERENCE + "[MEF SOAM-PM] R24, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 3 } + +mefSoamLmCurrentStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is set to false at the start of a measurement + interval. It is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service +" + REFERENCE + "[MEF SOAM-PM] R39, R40, R41" + ::= { mefSoamLmCurrentStatsEntry 4 } + +mefSoamLmCurrentStatsForwardTransmittedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames transmitted in the + forward direction by this MEP. + + For a PM Session of types lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of type lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 5 } + +mefSoamLmCurrentStatsForwardReceivedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames received in the + forward direction by this MEP. + + For a PM Session of types lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of types lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 6 } + +mefSoamLmCurrentStatsForwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 7 } + +mefSoamLmCurrentStatsForwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 8 } + +mefSoamLmCurrentStatsForwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 9 } + +mefSoamLmCurrentStatsBackwardTransmittedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames transmitted in the + backward direction by this MEP. + + For a PM Session of type lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of type lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 10 } + +mefSoamLmCurrentStatsBackwardReceivedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames received in the + backward direction by this MEP. + + For a PM Session of type lmLmm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of type lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 11 } + +mefSoamLmCurrentStatsBackwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 12 } + +mefSoamLmCurrentStatsBackwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed + as a percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 13 } + +mefSoamLmCurrentStatsBackwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmCurrentStatsEntry 14 } + +mefSoamLmCurrentStatsSoamPdusSent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM PDUs sent + during this Measurement Interval. + + This object applies when mefSoamLmCfgType is lmLmm, lmSlm, or + lmCcm. It indicates the number of LMM, CCM, or SLM SOAM frames + transmitted. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 15 } + +mefSoamLmCurrentStatsSoamPdusReceived OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM PDUs + PDUs received in this Measurement Interval. + + This object applies when mefSoamLmCfgType is lmLmm, lmSlm, or + lmCcm. This object indicates the number of LMR, CCM, or SLR SOAM + frames received. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmCurrentStatsEntry 16 } + +-- ***************************************************************************** +-- Ethernet Loss Measurement Availability History Statistic Table +-- ***************************************************************************** + +mefSoamLmHistoryAvailStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmHistoryAvailStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the results for availability history Measurement + Intervals in a SOAM Loss Measurement session. + + Rows of this table object are created automatically + by the SNMP Agent when the Loss Measurement session is running and a + Measurement Interval is completed. + + Each row in the table represents the history statistics for a Loss + Measurement session availability Measurement Interval for the defined + MEP. This table uses five indices. The first three indices are the indices of + the Maintenance Domain, MaNet, and MEP tables. The fourth index is the + specific LM session on the selected MEP. The fifth index index the + specific Measurement Interval. + + At least 32 completed Measurement Intervals are to be supported. 96 + completed Measurement Intervals are recommended to be supported. If + there are at least 32 rows in the table and a new Measurement Interval + completes and a new row is to be added to the table, the oldest completed + Measurement Interval can be deleted (row deletion). If the availability + Measurement Interval is other than 15 minutes then a minimum of 8 hours of + completed Measurement Intervals are to be supported and 24 hours are + recommended to be supported. + + Except for mefSoamLmHistoryAvailStatsIndex, + mefSoamLmHistoryAvailStatsEndTime, mefSoamLmHistoryAvailStatsElapsedTime and + mefSoamLmHistoryAvailStatsSuspect, each object in this table applies only + if the corresponding bit is set in mefSoamLmCfgMeasurementEnable. + + The rows and objects in this table are to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, R21, D8, R25" + ::= { mefSoamPmLmObjects 5 } + +mefSoamLmHistoryAvailStatsEntry OBJECT-TYPE + SYNTAX MefSoamLmHistoryAvailStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmHistoryAvailStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex, + mefSoamLmHistoryAvailStatsIndex + } + ::= { mefSoamLmHistoryAvailStatsTable 1 } + +MefSoamLmHistoryAvailStatsEntry ::= SEQUENCE { + mefSoamLmHistoryAvailStatsIndex Unsigned32, + mefSoamLmHistoryAvailStatsEndTime DateAndTime, + mefSoamLmHistoryAvailStatsElapsedTime TimeInterval, + mefSoamLmHistoryAvailStatsSuspect TruthValue, + mefSoamLmHistoryAvailStatsForwardHighLoss Unsigned32, + mefSoamLmHistoryAvailStatsBackwardHighLoss Unsigned32, + mefSoamLmHistoryAvailStatsForwardConsecutiveHighLoss Unsigned32, + mefSoamLmHistoryAvailStatsBackwardConsecutiveHighLoss Unsigned32, + + mefSoamLmHistoryAvailStatsForwardAvailable Gauge32, + mefSoamLmHistoryAvailStatsBackwardAvailable Gauge32, + mefSoamLmHistoryAvailStatsForwardUnavailable Gauge32, + mefSoamLmHistoryAvailStatsBackwardUnavailable Gauge32, + mefSoamLmHistoryAvailStatsForwardMinFlr Unsigned32, + mefSoamLmHistoryAvailStatsForwardMaxFlr Unsigned32, + mefSoamLmHistoryAvailStatsForwardAvgFlr Unsigned32, + mefSoamLmHistoryAvailStatsBackwardMinFlr Unsigned32, + mefSoamLmHistoryAvailStatsBackwardMaxFlr Unsigned32, + mefSoamLmHistoryAvailStatsBackwardAvgFlr Unsigned32 +} + +mefSoamLmHistoryAvailStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for the availability Measurement Interval within this + PM session. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. Measurement Intervals + for availability (stored in this table) are based on + mefSoamLmCfgAvailabilityMeasurementInterval and are indexed independently + of Measurement Intervals for FLR (stored in mefSoamLmHistoryStatsTable). + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never reused while this session is active until it wraps to zero. + The index value keeps increasing up to that time. + " + ::= { mefSoamLmHistoryAvailStatsEntry 1 } + +mefSoamLmHistoryAvailStatsEndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the Measurement Interval ended. + " + REFERENCE + "[MEF SOAM-PM] R23, R87, R112" + ::= { mefSoamLmHistoryAvailStatsEntry 2 } + +mefSoamLmHistoryAvailStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The length of time that the Measurement Interval ran for, + in 0.01 seconds. + " + REFERENCE + "[MEF SOAM-PM] R24, R87, R112" + ::= { mefSoamLmHistoryAvailStatsEntry 3 } + +mefSoamLmHistoryAvailStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service +" + REFERENCE + "[MEF SOAM-PM] R39, R40, R41, R42" + ::= { mefSoamLmHistoryAvailStatsEntry 4 } + +mefSoamLmHistoryAvailStatsForwardHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of high loss intervals (HLI) over + time in the forward direction. + + The value starts at 0 and increments for every HLI that occurs. + This parameter is equivalent to 'L Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 5 } + +mefSoamLmHistoryAvailStatsBackwardHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of high loss intervals (HLI) over + time in the backward direction. + + The value starts at 0 and increments for every HLI that occurs. + This parameter is equivalent to 'L Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 6 } + +mefSoamLmHistoryAvailStatsForwardConsecutiveHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of consecutive high loss intervals + (CHLI) over time in the forward direction. + + The value starts at 0 and increments for every HLI that occurs + that is determined to fall within a CHLI. + This parameter is equivalent to 'B Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 7 } + +mefSoamLmHistoryAvailStatsBackwardConsecutiveHighLoss OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object is the number of consecutive high loss intervals + (CHLI) over time in the forward direction. + + The value starts at 0 and increments for every HLI that occurs + that is determined to fall within a CHLI. + This parameter is equivalent to 'B Sub T' found in MEF 10.2.1. + " + REFERENCE + "[MEF 10.2.1] 6.9.9; [MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 8 } + +mefSoamLmHistoryAvailStatsForwardAvailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as available in the forward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87; [MEF 10.2.1]" + ::= { mefSoamLmHistoryAvailStatsEntry 9 } + +mefSoamLmHistoryAvailStatsBackwardAvailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as available in the backward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 10 } + +mefSoamLmHistoryAvailStatsForwardUnavailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as unavailable in the forward direction by this MEP during + this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 11 } + +mefSoamLmHistoryAvailStatsBackwardUnavailable OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of availability indicators + evaluated as unavailable in the backward direction by this MEP + during this Measurement Interval. + " + REFERENCE + "[MEF SOAM-PM] R87" + ::= { mefSoamLmHistoryAvailStatsEntry 12 } + +mefSoamLmHistoryAvailStatsForwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 13 } + +mefSoamLmHistoryAvailStatsForwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 14 } + +mefSoamLmHistoryAvailStatsForwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way availability flr in the forward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 15 } + +mefSoamLmHistoryAvailStatsBackwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 16 } + +mefSoamLmHistoryAvailStatsBackwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed + as a percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 17 } + +mefSoamLmHistoryAvailStatsBackwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way availability flr in the backward + direction, from among the set of availability flr values calculated by + the MEP in this Measurement Interval. There is one availability flr + value for each 'delta_t' time period within the Measurement Interval, as + specified in MEF 10.2.1. + + The flr value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryAvailStatsEntry 18 } + +-- ***************************************************************************** +-- Ethernet Loss Measurement Loss History Statistic Table +-- ***************************************************************************** + +mefSoamLmHistoryStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmHistoryStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the results for history Measurement + Intervals in a SOAM Loss Measurement session. + + Rows of this table object are created automatically + by the SNMP Agent when the Loss Measurement session is running and a + Measurement Interval is completed. + + Each row in the table represents the history statistics for a Loss + Measurement session Measurement Interval for the defined MEP. This + table uses five indices. The first three indices are the indices of + the Maintenance Domain, MaNet, and MEP tables. The fourth index is the + specific LM session on the selected MEP. The fifth index index the + specific Measurement Interval. + + At least 32 completed Measurement Intervals are to be supported. 96 + completed Measurement Intervals are recommended to be supported. If + there are at least 32 rows in the table and a new Measurement Interval + completes and a new row is to be added to the table, the oldest completed + Measurement Interval may be deleted (row deletion). If the measurement + interval is other than 15 minutes then a minimum of 8 hours of + completed Measurement Intervals are to be supported and 24 hours are + recommended to be supported. + + Except for mefSoamLmHistoryStatsIndex, mefSoamLmHistoryStatsEndTime, + mefSoamLmHistoryStatsElapsedTime and mefSoamLmHistoryStatsSuspect, + each object in this table applies only if the corresponding bit is set in + mefSoamLmCfgMeasurementEnable. + + The rows and objects in this table are to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, R21, D8, R25" + ::= { mefSoamPmLmObjects 6 } + +mefSoamLmHistoryStatsEntry OBJECT-TYPE + SYNTAX MefSoamLmHistoryStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmHistoryStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex, + mefSoamLmHistoryStatsIndex + } + ::= { mefSoamLmHistoryStatsTable 1 } + +MefSoamLmHistoryStatsEntry ::= SEQUENCE { + mefSoamLmHistoryStatsIndex Unsigned32, + mefSoamLmHistoryStatsEndTime DateAndTime, + mefSoamLmHistoryStatsElapsedTime TimeInterval, + mefSoamLmHistoryStatsSuspect TruthValue, + mefSoamLmHistoryStatsForwardTransmittedFrames Gauge32, + mefSoamLmHistoryStatsForwardReceivedFrames Gauge32, + mefSoamLmHistoryStatsForwardMinFlr Unsigned32, + mefSoamLmHistoryStatsForwardMaxFlr Unsigned32, + mefSoamLmHistoryStatsForwardAvgFlr Unsigned32, + mefSoamLmHistoryStatsBackwardTransmittedFrames Gauge32, + mefSoamLmHistoryStatsBackwardReceivedFrames Gauge32, + mefSoamLmHistoryStatsBackwardMinFlr Unsigned32, + mefSoamLmHistoryStatsBackwardMaxFlr Unsigned32, + mefSoamLmHistoryStatsBackwardAvgFlr Unsigned32, + mefSoamLmHistoryStatsSoamPdusSent Gauge32, + mefSoamLmHistoryStatsSoamPdusReceived Gauge32 +} + +mefSoamLmHistoryStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for the Measurement Interval within this + PM session. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. Measurement Intervals + for FLR (stored in this table) are based on + mefSoamLmCfgMeasurementInterval and are indexed independently + of Measurement Intervals for availability (stored in + mefSoamLmHistoryAvailStatsTable). + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never reused while this session is active until it wraps to zero. + The index value keeps increasing up to that time. + " + ::= { mefSoamLmHistoryStatsEntry 1 } + +mefSoamLmHistoryStatsEndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the Measurement Interval ended. + " + REFERENCE + "[MEF SOAM-PM] R23, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 2 } + +mefSoamLmHistoryStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The length of time that the Measurement Interval ran for, + in 0.01 seconds. + " + REFERENCE + "[MEF SOAM-PM] R24, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 3 } + +mefSoamLmHistoryStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service +" + REFERENCE + "[MEF SOAM-PM] R39, R40, R41, R42" + ::= { mefSoamLmHistoryStatsEntry 4 } + +mefSoamLmHistoryStatsForwardTransmittedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames transmitted in the + forward direction by this MEP. + + For a PM Session of types lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of type lmSlm this includes the count of OAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 5 } + +mefSoamLmHistoryStatsForwardReceivedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames received in the + forward direction by this MEP. + + For a PM Session of types lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of type lmSlm this includes the count of OAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 6 } + +mefSoamLmHistoryStatsForwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 7 } + +mefSoamLmHistoryStatsForwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 8 } + +mefSoamLmHistoryStatsForwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame loss + ratio in the forward direction calculated by this MEP for this + Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 9 } + +mefSoamLmHistoryStatsBackwardTransmittedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames transmitted in the + backward direction by this MEP. + + For a PM Session of type lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of types lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 10 } + +mefSoamLmHistoryStatsBackwardReceivedFrames OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the number of frames received in the + backward direction by this MEP. + + For a PM Session of type lmLmm and lmCcm this includes Ethernet + Service Frames and SOAM PDUs that are in a higher MEG level only. + + For a PM Session of types lmSlm this includes the count of SOAM + ETH-SLM frames only. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 11 } + +mefSoamLmHistoryStatsBackwardMinFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] R69, R87, R112" + ::= { mefSoamLmHistoryStatsEntry 12 } + +mefSoamLmHistoryStatsBackwardMaxFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 13 } + +mefSoamLmHistoryStatsBackwardAvgFlr OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame loss + ratio in the backward direction calculated by this MEP for + this Measurement Interval. The FLR value is a ratio that is expressed as a + percent with a value of 0 (ratio 0.00) through 100000 (ratio 1.00). + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + REFERENCE + "[MEF SOAM-PM] D37" + ::= { mefSoamLmHistoryStatsEntry 14 } + +mefSoamLmHistoryStatsSoamPdusSent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM PDUs sent + during this Measurement Interval. + + This object applies when mefSoamLmCfgType is lmLmm, lmSlm, + or lmCcm. It indicates the number of LMM, CCM, or SLM SOAM frames + transmitted. + " + REFERENCE + "[MEF SOAM-PM] R69, R87" + ::= { mefSoamLmHistoryStatsEntry 15 } + +mefSoamLmHistoryStatsSoamPdusReceived OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM + PDUs received in this Measurement Interval. + + This object applies when mefSoamLmCfgType is lmLmm, lmSlm, + or lmCcm. This object indicates the number of LMR, CCM, or SLR + SOAM frames received. + " + REFERENCE + "[MEF SOAM-PM] R69, R87" + ::= { mefSoamLmHistoryStatsEntry 16 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Configuration Table +-- ***************************************************************************** + +mefSoamDmCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table includes configuration objects and operations for the + Delay Measurement function. + + Each row in the table represents a Delay Measurement session for + the defined MEP. This table uses four indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific DM session on the selected MEP. + + A Delay Measurement session is created on an existing MEP by first + accessing the mefSoamDmOperNextIndex object and using this value as + the mefSoamDmCfgIndex in the row creation. + + Some writable objects in this table are only applicable in certain cases + (as described under each object), and attempts to write values for them + in other cases will be ignored. + + The writable objects in this table need to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R50; [Y.1731]" + ::= { mefSoamPmDmObjects 1 } + +mefSoamDmCfgEntry OBJECT-TYPE + SYNTAX MefSoamDmCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmCfgTable." + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex + } + ::= { mefSoamDmCfgTable 1 } + +MefSoamDmCfgEntry ::= SEQUENCE { + mefSoamDmCfgIndex Unsigned32, + mefSoamDmCfgType INTEGER, + mefSoamDmCfgVersion Unsigned32, + mefSoamDmCfgEnabled TruthValue, + mefSoamDmCfgMeasurementEnable BITS, + mefSoamDmCfgMessagePeriod MefSoamTcMeasurementPeriodType, + + mefSoamDmCfgPriority IEEE8021PriorityValue, + mefSoamDmCfgFrameSize Unsigned32, + mefSoamDmCfgDataPattern MefSoamTcDataPatternType, + mefSoamDmCfgTestTlvIncluded TruthValue, + mefSoamDmCfgTestTlvPattern MefSoamTcTestPatternType, + mefSoamDmCfgMeasurementInterval Unsigned32, + mefSoamDmCfgNumIntervalsStored Unsigned32, + + mefSoamDmCfgDestMacAddress MacAddress, + mefSoamDmCfgDestMepId Dot1agCfmMepIdOrZero, + mefSoamDmCfgDestIsMepId TruthValue, + mefSoamDmCfgSourceMacAddress MacAddress, + + mefSoamDmCfgStartTimeType MefSoamTcOperationTimeType, + mefSoamDmCfgFixedStartDateAndTime DateAndTime, + mefSoamDmCfgRelativeStartTime TimeInterval, + mefSoamDmCfgStopTimeType MefSoamTcOperationTimeType, + mefSoamDmCfgFixedStopDateAndTime DateAndTime, + mefSoamDmCfgRelativeStopTime TimeInterval, + mefSoamDmCfgRepetitionTime Unsigned32, + + mefSoamDmCfgAlignMeasurementIntervals TruthValue, + mefSoamDmCfgAlignMeasurementOffset Unsigned32, + mefSoamDmCfgNumMeasBinsPerFrameDelayInterval Unsigned32, + mefSoamDmCfgNumMeasBinsPerInterFrameDelayVariationInterval + Unsigned32, + mefSoamDmCfgInterFrameDelayVariationSelectionOffset + Unsigned32, + mefSoamDmCfgNumMeasBinsPerFrameDelayRangeInterval Unsigned32, + + mefSoamDmCfgSessionType MefSoamTcSessionType, + mefSoamDmCfgSessionStatus MefSoamTcStatusType, + mefSoamDmCfgHistoryClear TruthValue, + mefSoamDmCfgRowStatus RowStatus +} + +mefSoamDmCfgIndex +OBJECT-TYPE + SYNTAX Unsigned32(1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An index to the Delay Measurement Configuration table which indicates + the specific measurement session for the MEP. + + mefSoamPmMepOperNextIndex needs to be inspected to find an + available index for row-creation. + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never reused for other PM sessions on the same MEP while this + session is active. The index value keeps increasing until it + wraps to zero. This is to facilitate access control based + on a fixed index for an EMS, since the index is not reused. + " + ::= { mefSoamDmCfgEntry 1 } + +mefSoamDmCfgType OBJECT-TYPE + SYNTAX INTEGER { + dmDmm (1), + dm1DmTx (2), + dm1DmRx (3) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates what type of Delay Measurement is to + be performed. + + dmDmm(1) DMM SOAM PDU generated, DMR responses received + (one-way or two-way measurements) + dm1DmTx(2) 1DM SOAM PDU generated (one-way measurements are made by + the receiver) + dm1DmRx(3) 1DM SOAM PDU received and tracked (one-way measurements) + + The exact PDUs to use are specified by this object in combination with + mefSoamDmCfgVersion. + + The value dmDMM is required. The values dm1DmTx and dm1DmRx are optional. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R52, R53, R54, O5, R88" + ::= { mefSoamDmCfgEntry 2 } + +mefSoamDmCfgVersion OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates the version of the PDUs used to perform + Delay Measurement. + + Version 0 indicates the PDU formats defined in Y.1731-2008. + Version 1 indicates the PDU formats defined in Y.1731-2011. + + The exact PDUs to use are specified by this object in combination with + mefSoamDmCfgType. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[Y.1731]" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 3 } + +mefSoamDmCfgEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies whether the Delay Measurement session is + enabled. + + The value 'true' indicates the Delay Measurement session is enabled AND + SOAM PDUs are sent and/or measurements are collected when the session + is running according to the scheduling objects (start time, stop time, + etc.). + + The value 'false' indicates the Delay Measurement session is disabled + AND SOAM PDUs are not sent and/or measurements collected. + + For a Delay Measurement session to be removed the row is deleted in + order to release internal resources. + + This object can written/modified after row creation time. + + If the DM session is enabled it resumes after shutdown/restart. + + If the DM session is disabled the current Measurement Interval is + stopped, if it in process at the time, and all the in process calculations + for the partially completed Measurement Interval are finalized. + + This object does not affect whether the single-ended Responder is + enabled or not, which is enabled or disabled by the + mefSoamPmMepDmSingleEndedResponder object. + " + REFERENCE + "[MEF SOAM-PM] R4, R5, R6, O1, R12, R14" + DEFVAL { true } + ::= { mefSoamDmCfgEntry 4 } + +mefSoamDmCfgMeasurementEnable OBJECT-TYPE + SYNTAX BITS { + bSoamPdusSent(0), + bSoamPdusReceived(1), + bFrameDelayTwoWayBins(2), + bFrameDelayTwoWayMin(3), + bFrameDelayTwoWayMax(4), + bFrameDelayTwoWayAvg(5), + bFrameDelayForwardBins(6), + bFrameDelayForwardMin(7), + bFrameDelayForwardMax(8), + bFrameDelayForwardAvg(9), + bFrameDelayBackwardBins(10), + bFrameDelayBackwardMin(11), + bFrameDelayBackwardMax(12), + bFrameDelayBackwardAvg(13), + bIfdvForwardBins(14), + bIfdvForwardMin(15), + bIfdvForwardMax(16), + bIfdvForwardAvg(17), + bIfdvBackwardBins(18), + bIfdvBackwardMin(19), + bIfdvBackwardMax(20), + bIfdvBackwardAvg(21), + bIfdvTwoWayBins(22), + bIfdvTwoWayMin(23), + bIfdvTwoWayMax(24), + bIfdvTwoWayAvg(25), + bFrameDelayRangeForwardBins(26), + bFrameDelayRangeForwardMax(27), + bFrameDelayRangeForwardAvg(28), + bFrameDelayRangeBackwardBins(29), + bFrameDelayRangeBackwardMax(30), + bFrameDelayRangeBackwardAvg(31), + bFrameDelayRangeTwoWayBins(32), + bFrameDelayRangeTwoWayMax(33), + bFrameDelayRangeTwoWayAvg(34), + bMeasuredStatsFrameDelayTwoWay(35), + bMeasuredStatsFrameDelayForward(36), + bMeasuredStatsFrameDelayBackward(37), + bMeasuredStatsIfdvTwoWay(38), + bMeasuredStatsIfdvForward(39), + bMeasuredStatsIfdvBackward(40) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A vector of bits that indicates the type of SOAM DM counters that + are enabled. + + A bit set to '1' enables the specific SOAM DM counter. + + A bit set to '0' disables the SOAM DM counter. + + If a particular SOAM DM counter is not supported the BIT value is + set to '0'. + + Not all SOAM DM counters are supported for all SOAM DM types. + + This object can only be written at row creation time and cannot be + modified once it has been created. + + bSoamPdusSent(0) + Enables/disables the mefSoamDmCurrentStatsSoamPdusSent + and mefSoamDmHistoryStatsSoamPdusSent counters. + bSoamPdusReceived(1) + Enables/disables the mefSoamDmCurrentStatsSoamPdusReceived + and mefSoamDmHistoryStatsSoamPdusReceived counters. + bFrameDelayTwoWayBins(2) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'twoWayFrameDelay'. + bFrameDelayTwoWayMin(3) + Enables/disables the mefSoamDmCurrentStatsFrameDelayTwoWayMin + and mefSoamDmHistoryStatsFrameDelayTwoWayMin counters. + bFrameDelayTwoWayMax(4) + Enables/disables the mefSoamDmCurrentStatsFrameDelayTwoWayMax + and mefSoamDmHistoryStatsFrameDelayTwoWayMax counters. + bFrameDelayTwoWayAvg(5) + Enables/disables the mefSoamDmCurrentStatsFrameDelayTwoWayAvg + and mefSoamDmHistoryStatsFrameDelayTwoWayAvg counters. + bFrameDelayForwardBins(6) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'forwardFrameDelay'. + bFrameDelayForwardMin(7) + Enables/disables the mefSoamDmCurrentStatsFrameDelayForwardMin + and mefSoamDmHistoryStatsFrameDelayForwardMin counters. + bFrameDelayForwardMax(8) + Enables/disables the mefSoamDmCurrentStatsFrameDelayForwardMax + and mefSoamDmHistoryStatsFrameDelayForwardMax counters. + bFrameDelayForwardAvg(9) + Enables/disables the mefSoamDmCurrentStatsFrameDelayForwardAvg + and mefSoamDmHistoryStatsFrameDelayForwardAvg counters. + bFrameDelayBackwardBins(10) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'backwardFrameDelay'. + bFrameDelayBackwardMin(11) + Enables/disables the mefSoamDmCurrentStatsFrameDelayBackwardMin + and mefSoamDmHistoryStatsFrameDelayBackwardMin counters. + bFrameDelayBackwardMax(12) + Enables/disables the mefSoamDmCurrentStatsFrameDelayBackwardMax + and mefSoamDmHistoryStatsFrameDelayBackwardMax counters. + bFrameDelayBackwardAvg(13) + Enables/disables the mefSoamDmCurrentStatsFrameDelayBackwardAvg + and mefSoamDmHistoryStatsFrameDelayBackwardAvg counters. + bIfdvForwardBins(14) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'forwardIfdv'. + bIfdvForwardMin(15) + Enables/disables the mefSoamDmCurrentStatsIfdvForwardMin + and mefSoamDmHistoryStatsIfdvForwardMin counters. + bIfdvForwardMax(16) + Enables/disables the mefSoamDmCurrentStatsIfdvForwardMax + and mefSoamDmHistoryStatsIfdvForwardMax counters. + bIfdvForwardAvg(17) + Enables/disables the mefSoamDmCurrentStatsIfdvForwardAvg + and mefSoamDmHistoryStatsIfdvForwardAvg counters. + bIfdvBackwardBins(18) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'backwardIfdv'. + bIfdvBackwardMin(19) + Enables/disables the mefSoamDmCurrentStatsIfdvBackwardMin + and mefSoamDmHistoryStatsIfdvBackwardMin counters. + bIfdvBackwardMax(20) + Enables/disables the mefSoamDmCurrentStatsIfdvBackwardMax + and mefSoamDmHistoryStatsIfdvBackwardMax counters. + bIfdvBackwardAvg(21) + Enables/disables the mefSoamDmCurrentStatsIfdvBackwardAvg + and mefSoamDmHistoryStatsIfdvBackwardAvg counters. + bIfdvTwoWayBins(22) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'twoWayIfdv'. + bIfdvTwoWayMin(23) + Enables/disables the mefSoamDmCurrentStatsIfdvTwoWayMin + and mefSoamDmHistoryStatsIfdvTwoWayMin counters. + bIfdvTwoWayMax(24) + Enables/disables the mefSoamDmCurrentStatsIfdvTwoWayMax + and mefSoamDmHistoryStatsIfdvTwoWayMax counters. + bIfdvTwoWayAvg(25) + Enables/disables the mefSoamDmCurrentStatsIfdvTwoWayAvg + and mefSoamDmHistoryStatsIfdvTwoWayAvg counters. + bFrameDelayRangeForwardBins(26) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'forwardFrameDelayRange'. + bFrameDelayRangeForwardMax(27) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeForwardMax + and mefSoamDmHistoryStatsFrameDelayRangeForwardMax counters. + bFrameDelayRangeForwardAvg(28) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeForwardAvg + and mefSoamDmHistoryStatsFrameDelayRangeForwardAvg counters. + bFrameDelayRangeBackwardBins(29) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'backwardFrameDelayRange'. + bFrameDelayRangeBackwardMax(30) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeBackwardMax + and mefSoamDmHistoryStatsFrameDelayRangeBackwardMax counters. + bFrameDelayRangeBackwardAvg(31) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg + and mefSoamDmHistoryStatsFrameDelayRangeBackwardAvg counters. + bFrameDelayRangeTwoWayBins(32) + Enables/disables the mefSoamDmCurrentStatsBinsEntry counter + and the mefSoamDmHistoryStatsBinsEntry counter + when the mefSoamDmCfgMeasBinType is 'twoWayFrameDelayRange'. + bFrameDelayRangeTwoWayMax(33) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax + and mefSoamDmHistoryStatsFrameDelayRangeTwoWayMax counters. + bFrameDelayRangeTwoWayAvg(34) + Enables/disables the mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg + and mefSoamDmHistoryStatsFrameDelayRangeTwoWayAvg counters. + bMeasuredStatsFrameDelayTwoWay(35) + Enables/disables the mefSoamDmMeasuredStatsFrameDelayTwoWay + counter. + bMeasuredStatsFrameDelayForward(36) + Enables/disables the mefSoamDmMeasuredStatsFrameDelayForward + counter. + bMeasuredStatsFrameDelayBackward(37) + Enables/disables the mefSoamDmMeasuredStatsFrameDelayBackward + counter. + bMeasuredStatsIfdvTwoWay(38) + Enables/disables the mefSoamDmMeasuredStatsIfdvTwoWay + counter. + bMeasuredStatsIfdvForward(39) + Enables/disables the mefSoamDmMeasuredStatsIfdvForward + counter. + bMeasuredStatsIfdvBackward(40) + Enables/disables the mefSoamDmMeasuredStatsIfdvBackward + counter. + " + REFERENCE + "[MEF SOAM-PM]" + DEFVAL { { } } + ::= { mefSoamDmCfgEntry 5 } + +mefSoamDmCfgMessagePeriod OBJECT-TYPE + SYNTAX MefSoamTcMeasurementPeriodType + UNITS "ms" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the interval between Delay Measurement + OAM message transmission. For Delay Measurement monitoring + applications, the default value is 100ms. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R61, R62, D22, R95, R96, D39" + DEFVAL { 100 } + ::= { mefSoamDmCfgEntry 6 } + +mefSoamDmCfgPriority OBJECT-TYPE + SYNTAX IEEE8021PriorityValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the priority of frames with + Delay Measurement OAM message information. + + The default value is to be the value which yields the lowest frame + loss. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R1, R2, R56, D21, R57, R58, R90-R94, D28; + [MEF 10.2.1] Section 6.8" + ::= { mefSoamDmCfgEntry 7 } + +mefSoamDmCfgFrameSize OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the Delay Measurement frame size between + 64 bytes and the maximum transmission unit of the EVC. + + The range of frame sizes from 64 through 2000 octets need to be + supported, and the range of frame sizes from 2001 through 9600 octets + is suggested to be supported. + + The adjustment to the frame size of the standard frame size is + accomplished by the addition of a Data or Test TLV. A Data or Test TLV + is only added to the frame if the frame size is greater than 64 bytes. + + This object is only valid for the entity transmitting the Delay + Measurement frames (dmDmm, dm1DmTx) and is ignored by the entity + receiving frames. + + In addition, this object is not valid when mefSoamDmCfgVersion is 0. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R63, R64, D23, D24, R97, R98, D40, D41" + DEFVAL { 64 } + ::= { mefSoamDmCfgEntry 8 } + +mefSoamDmCfgDataPattern OBJECT-TYPE + SYNTAX MefSoamTcDataPatternType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the DM data pattern included in a Data TLV + when the size of the DM frame is determined by the + mefSoamDmFrameSize object and mefSoamDmTestTlvIncluded is 'false'. + If the frame size object does not define the DM frame size or + mefSoamDmTestTlvIncluded is 'true' the value of this object is + ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + DEFVAL { zeroPattern } + ::= { mefSoamDmCfgEntry 9 } + +mefSoamDmCfgTestTlvIncluded OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "Indicates whether a Test TLV or Data TLV is included when the size + of the DM frame is determined by the mefSoamDmFrameSize object. + A value of 'true' indicates that the Test TLV is to be included. A + value of 'false' indicates that the Data TLV is to be included. + + If the frame size object does not define the DM frame size + the value of this object is ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[Y.1731] 9.3" + DEFVAL { false } + ::= { mefSoamDmCfgEntry 10 } + +mefSoamDmCfgTestTlvPattern OBJECT-TYPE + SYNTAX MefSoamTcTestPatternType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of test pattern to be + sent in the DM frame Test TLV when the size + of DM PDU is determined by the mefSoamDmFrameSize object and + mefSoamDmTestTlvIncluded is 'true'. If the frame size object + does not define the DM frame size or mefSoamDmTestTlvIncluded + is 'false' the value of this object is ignored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + DEFVAL { null } + ::= { mefSoamDmCfgEntry 11 } + +mefSoamDmCfgMeasurementInterval OBJECT-TYPE + SYNTAX Unsigned32 (1..1440) + UNITS "minutes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a Measurement Interval in minutes. + + A Measurement Interval 15 minutes needs to be supported, other intervals + may be supported. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R16, R17" + DEFVAL { 15 } + ::= { mefSoamDmCfgEntry 12 } + +mefSoamDmCfgNumIntervalsStored OBJECT-TYPE + SYNTAX Unsigned32 (2..1000) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the number of completed Measurement Intervals + to store in the history statistic table. + + At least 32 completed Measurement Intervals are to be stored. 96 + Measurement Intervals are recommended to be stored. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R21, D8, D9" + DEFVAL { 32 } + ::= { mefSoamDmCfgEntry 13 } + +mefSoamDmCfgDestMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Target or Destination MAC Address Field to be transmitted. + + If mefSoamDmCfgType is 'dmDmm', the destination address is to be the + unicast address of the destination MEP. An error is returned if this + object is set to a multicast address. + + If mefSoamDmCfgType is 'dm1DmTx', the destination address is normally the + unicast address of the destination MEP, but can be a multicast address + indicating the level of the MEG: 01-80-c2-00-00-3y, where y is the + level of the MEG. An error is returned if this object is set to any + other multicast address. + + If mefSoamDmCfgType is 'dm1DmRx', this object is ignored. + + This address will be used if the value of the object + mefSoamDmDestIsMepId is 'false'. + + This object is only valid for the entity transmitting the + SOAM DM frames and is ignored by the entity receiving + SOAM DM frames. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R55, R89" + ::= { mefSoamDmCfgEntry 14 } + +mefSoamDmCfgDestMepId OBJECT-TYPE + SYNTAX Dot1agCfmMepIdOrZero + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Maintenance Association End Point Identifier of + another MEP in the same Maintenance Association to which + the SOAM DM frame is to be sent. + + This address will be used if the value of the column + mefSoamDmDestIsMepId is 'true'. A value of zero + means that the destination MEP ID has not been configured. + + This object is only valid for the entity transmitting the Delay + Measurement frames, types 'dmDmm' and 'dm1DmTx'. It is not applicable + for the 'dm1DmRx' type. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R55, R89" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 15 } + +mefSoamDmCfgDestIsMepId OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A value of 'true' indicates that MEPID of the target MEP is used for + SOAM DM frame transmission. + + A value of 'false' indicates that the destination MAC address of the + target MEP is used for SOAM DM frame transmission. + + This object is only valid for the entity transmitting the Delay + Measurement frames, types 'dmDmm' and 'dm1DmTx'. It is not applicable + for the 'dm1DmRx type. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R55, R89" + DEFVAL { true } + ::= { mefSoamDmCfgEntry 16 } + +mefSoamDmCfgSourceMacAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The Source MAC Address Field of the received SOAM DM session PDUs. + + If mefSoamDmCfgType is dm1DmRx this object indicates the source + address of the dm1DmTx DM session. + + This object is only valid for mefSoamDmCfgType set to dm1DmRx. It is + ignored for mefSoamDmCfgType set to dmDmm or dm1DmTx. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R55, R89" + ::= { mefSoamDmCfgEntry 17 } + +mefSoamDmCfgStartTimeType OBJECT-TYPE + SYNTAX MefSoamTcOperationTimeType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of start time of the SOAM DM + session. The start time can be disabled (none), immediate, relative, + or fixed. + + The value of 'none' is illegal and a write error will be returned + if this value is used. + + The value of 'immediate' starts the SOAM DM session when the + mefSoamDmCfgEnabled is true. + + The value of 'fixed' starts the SOAM DM session when the + mefSoamDmFixedStartDateAndTime is less than or equal to the current + system date and time and mefSoamDmCfgEnabled is true. This value is used + to implement an On-Demand fixed time PM session. + + The value of 'relative' starts the SOAM DM session when the current + system date and time minus the mefSoamDmRelativeStartTime is greater than + or equal to the system date and time when the mefSoamDmStartTimeType + object was written and mefSoamDmCfgEnabled is true. This value is used + to implement an On-Demand relative time PM session. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3, R7, R8, D1" + DEFVAL { immediate } + ::= { mefSoamDmCfgEntry 18 } + +mefSoamDmCfgFixedStartDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the fixed start date/time for the + SOAM Delay Measurement session. This object is used only used if + mefSoamDmStartTimeType is 'fixed' and is ignored otherwise. + + The default value is year 0000, month 01, day 01, time 00:00:00.00. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R9" + DEFVAL { '0000010100000000'H } + ::= { mefSoamDmCfgEntry 19 } + +mefSoamDmCfgRelativeStartTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the relative start time, from + the current system time, for the SOAM DM session. This + object is used only if mefSoamDmStartTimeType is 'relative' + and is ignored otherwise. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R9" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 20 } + +mefSoamDmCfgStopTimeType OBJECT-TYPE + SYNTAX MefSoamTcOperationTimeType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the type of stop time to terminate the + SOAM DM session. The stop time can be forever (none), relative, or + fixed. + + The value of 'none' indicates that the SOAM DM session never ends once it + has started unless the session is disabled. + + The value of 'immediate' is illegal and a write error will be returned + if this value is used. + + The value of 'fixed' stops the SOAM DM session when the + mefSoamDmFixedStopDateAndTime is less than or equal + to the current system date. This + value is used to implement an On-Demand fixed time PM session. + + The value of 'relative' stops the SOAM DM session when the time + indicated by mefSoamDmRelativeStopTime has passed since the session + start time as determined by the mefSoamDmCfgStartTimeType, + mefSoamDmCfgFixedStartDateAndTime and mefSoamDmCfgRelativeStartTime + objects. + This value is used to implement an On-Demand relative time PM session. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3, R10, D2" + DEFVAL { none } + ::= { mefSoamDmCfgEntry 21 } + +mefSoamDmCfgFixedStopDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the fixed stop date/time for the + SOAM Delay Measurement session. This object is used only used + if mefSoamDmStopTimeType is 'fixed' and is ignored otherwise. + + The default value is year 0000, month 01, day 01, time 00:00:00.00. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R10, R13" + DEFVAL { '0000010100000000'H } + ::= { mefSoamDmCfgEntry 22 } + +mefSoamDmCfgRelativeStopTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the relative stop time, from the + session start time, to stop the SOAM DM session. This + object is used only if mefSoamDmStopTimeType is 'relative' and is + ignored otherwise. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R11" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 23 } + +mefSoamDmCfgRepetitionTime OBJECT-TYPE + SYNTAX Unsigned32 (0..31536000) + UNITS "seconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies a configurable repetition time between + Measurement Intervals in a Delay Measurement session in seconds. + + If the value is 0 (none), there is no time gap between the end of one + Measurement Interval and the start of a new Measurement Interval. + This is the normal usage case. + + If the value is greater than one Measurement Interval there is time gap + between the end of one Measurement Interval and the start of the next + Measurement Interval. The repetition time specifies the time between + the start of consecutive Measurement Intervals; hence the gap between + the end of one Measurement Interval and the start of the next is equal + to the difference between the repetition time and the measurement + interval. During this gap, no SOAM PDUs are sent for this session and + no measurements are made. + + If the value is greater 0 but less than or equal to the measurement + interval, an error is returned. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R18, D3, R19, R20" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 24 } + +mefSoamDmCfgAlignMeasurementIntervals OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies whether the Measurement Intervals for + the Delay Measurement session are aligned with a zero offset to + real time. + + The value 'true' indicates that each Measurement Interval starts + at a time which is aligned to NE time source hour, if the repetition + time (or the Measurement Interval, if the repetition time is 0) is + a factor of an hour, i.e. 60min/15min = 4. For instance, a + Measurement Interval/Repetition Time of 15 minutes would stop/start + the Measurement Interval at 0, 15, 30, and 45 minutes of an hour. A + Measurement Interval/Repetition Time of 7 minutes would not align + to the hour since 7 minutes is NOT a factor of an hour, i.e. + 60min/7min = 8.6. In this case the behavior is the same as if the + object is set to 'false'. + + The value 'false' indicates that the first Measurement Interval starts + at an arbitrary time and each subsequent Measurement Interval starts + at a time which is determined by mefSoamLmCfgRepetitionTime. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] D4, D5, D6" + DEFVAL { true } + ::= { mefSoamDmCfgEntry 25 } + +mefSoamDmCfgAlignMeasurementOffset OBJECT-TYPE + SYNTAX Unsigned32 (0..525600) + UNITS "minutes" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the offset in minutes from the time of day value + if mefSoamDmCfgAlignMeasurementIntervals is 'true' and the repetition + time is a factor of 60 minutes. If not, the value of this object + is ignored. + + If the Measurement Interval is 15 minutes and + mefSoamDmCfgAlignMeasurementIntervals is true and if this object was + set to 5 minutes, the Measurement Intervals would start at 5, 20, 35, 50 + minutes past each hour. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] D7" + DEFVAL { 0 } + ::= { mefSoamDmCfgEntry 26 } + +mefSoamDmCfgNumMeasBinsPerFrameDelayInterval OBJECT-TYPE + SYNTAX Unsigned32 (2..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the number of measurement bins + per Measurement Interval for Frame Delay measurements. + + At least 3 bins are to be supported; at least 10 bins are recommended + to be supported. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R27, D11, R28, D12" + DEFVAL { 3 } + ::= { mefSoamDmCfgEntry 27 } + +mefSoamDmCfgNumMeasBinsPerInterFrameDelayVariationInterval OBJECT-TYPE + SYNTAX Unsigned32 (2..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the number of measurement bins + per Measurement Interval for Inter-Frame Delay Variation + measurements. + + The minimum number of measurement bins to be supported is 2. The + desired number of measurements bins to be supported is 10. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R29, D13, R30, D14" + DEFVAL { 2 } + ::= { mefSoamDmCfgEntry 28 } + +mefSoamDmCfgInterFrameDelayVariationSelectionOffset OBJECT-TYPE + SYNTAX Unsigned32 (1..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the selection offset for + Inter-Frame Delay Variation measurements. If this value + is set to n, then the IFDV is calculated by taking the + difference in frame delay between frame F and frame (F+n). + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] O4, D25, O6, D42" + DEFVAL { 1 } + ::= { mefSoamDmCfgEntry 29 } + +mefSoamDmCfgNumMeasBinsPerFrameDelayRangeInterval OBJECT-TYPE + SYNTAX Unsigned32 (2..100) + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object specifies the number of measurement bins + per Measurement Interval for Frame Delay Range measurements. + + At least 2 bins are to be supported; at least 10 bins are recommended + to be supported. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R31, D15, R32, D16" + DEFVAL { 2 } + ::= { mefSoamDmCfgEntry 30 } + +mefSoamDmCfgSessionType OBJECT-TYPE + SYNTAX MefSoamTcSessionType + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object indicates whether the current session is defined to + be 'Proactive' or 'On-Demand'. A value of 'proactive' + indicates the current session is 'Proactive'. A value of 'onDemand' + indicates the current session is 'On-Demand'. + + This object can only be written at row creation time and cannot be + modified once it has been created. + " + REFERENCE + "[MEF SOAM-PM] R3" + DEFVAL { proactive } + ::= { mefSoamDmCfgEntry 31 } + +mefSoamDmCfgSessionStatus OBJECT-TYPE + SYNTAX MefSoamTcStatusType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object indicates the current status of the DM session. A value + of 'active' indicates the current DM session is active, i.e. the current + time lies between the start time and the stop time, and + mefSoamDmCfgEnabled is true. A value of 'notActive' indicates the + current DM session is not active, i.e. it has not started yet, has + stopped upon reaching the stop time, or is disabled. + " + ::= { mefSoamDmCfgEntry 32 } + +mefSoamDmCfgHistoryClear OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object when written clears the Delay Measurement history + tables (mefSoamDmHistoryStatsTable and mefSoamDmHistoryStatsBinsTable) + - all rows are deleted. When read the value always returns 'false'. + + Writing this value does not change the current stat table, + nor any of the items in the configuration table. + + Writing this object at row creation has no effect. + " + DEFVAL { false } + ::= { mefSoamDmCfgEntry 33 } + +mefSoamDmCfgRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of the row. + + The writable columns in a row cannot be changed if the row + is active, except for mefSoamDmCfgEnabled and mefSoamDmCfgHistoryClear + objects. All columns are to have a valid value before a row + can be activated. + " + ::= { mefSoamDmCfgEntry 34 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Bin Configuration Table +-- ***************************************************************************** + +mefSoamDmCfgMeasBinTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmCfgMeasBinEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table includes configuration objects for the Delay Measurement + bins to collect stats. + + Each row in the table is automatically created when the Delay + Measurement session is defined for the selected MEP. The number of rows + created is based upon three items: the DM type, the number of bins + defined for each type, and whether bins are enabled for each type. + + The first four indices are the same as used to create the DM session: + Maintenance Domain, MaNet, MEP identification, and mefSoamDmCfgIndex. The + fifth index is the type of bin, and the sixth index is the bin number. + + For a dmDmm session all nine types of bins can be created. For a dm1DmmTx + session no bins are created. For a dm1DmmRx session only types + forwardFrameDelay, forwardIfdv, and forwardFrameDelayRange can be created. + + The number of bins created for a bin type is based upon: the + mefSoamDmCfgNumMeasBinsPerFrameDelayInterval object, the + mefSoamDmCfgNumMeasBinsPerInterFrameDelayVariationInterval object, the + mefSoamDmCfgNumMeasBinsPerFrameDelayRangeInterval object, and + the mefSoamDmCfgMeasurementEnable object. + + For instance, if a dmDmm session with Bins per Frame Delay Interval + set to 5, Bins per Frame Delay Variation Interval set to 3, and Frame + Delay Range set to 2 (default), all of the appropriate bits set in + mefSoamDmMeasurementCfgEnable, the following number of rows would be + created: + + For bin types TwoWayFrameDelay(1), forwardFrameDelay(2), and + backwardFrameDelay(3) = 5 bins * 3 types = 15 rows + + For bin types TwoWayIfdv(4), forwardIfdv(5), backwardIfdv(6) = + 3 bins * 3 types = 9 rows. + + For bins types twoWayFrameDelayRange(7), forwardFrameDelayRange(8), + backwardFrameDelayRange(9) = + 2 bins * 3 types = 6 rows. + + This gives a total of 30 rows created for the DMM session example. + + Each value in the bin defaults to 5000us greater than the previous bin, + with the first bin default value set to 0. + + For the delay example above (5 bins), the following default values + would be written to the bins: + bin 1: 0 (range is 0us <= measurement < 5,000us) + bin 2: 5000 (range is 5,000us <= measurement < 10,000us) + bin 3: 10000 (range is 10,000us <= measurement < 15,000us) + bin 4: 15000 (range is 15,000us <= measurement < 20,000us) + bin 5: 20000 (range is 20,000us <= measurement < infinity) + + For the delay variation example above (3 bins), the following default + values would be written to the bins: + bin 1: 0 (range is 0us <= measurement < 5,000us) + bin 2: 5000 (range is 5,000us <= measurement < 10,000us) + bin 3: 10000 (range is 10,000us <= measurement < infinity) + + For the frame delay range example above (2 bins), the following default + values would be written to the bins: + bin 1: 0 (range is 0us <= measurement < 5,000us) + bin 2: 5000 (range is 5,000us <= measurement < infinity) + + The writable objects in this table need to be persistent upon reboot + or restart of a device. + + Rows are only created if the corresponding measurement type has been enabled + via the mefSoamDmCfgMeasurementEnable object. + " + REFERENCE + "[MEF SOAM-PM] R34, R36, R37, D17, R38, R65, D26, D27, R99, D43, D44" + ::= { mefSoamPmDmObjects 2 } + +mefSoamDmCfgMeasBinEntry OBJECT-TYPE + SYNTAX MefSoamDmCfgMeasBinEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmCfgMeasBinTable." + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex, + mefSoamDmCfgMeasBinType, + mefSoamDmCfgMeasBinNumber + } + ::= { mefSoamDmCfgMeasBinTable 1 } + +MefSoamDmCfgMeasBinEntry ::= SEQUENCE { + mefSoamDmCfgMeasBinType MefSoamTcDelayMeasurementBinType, + mefSoamDmCfgMeasBinNumber Unsigned32, + mefSoamDmCfgMeasBinLowerBound Unsigned32 +} + +mefSoamDmCfgMeasBinType OBJECT-TYPE + SYNTAX MefSoamTcDelayMeasurementBinType + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies whether the bin number is for + Frame Delay or Inter-Frame Delay Variation. + " + ::= { mefSoamDmCfgMeasBinEntry 1 } + +mefSoamDmCfgMeasBinNumber OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object specifies the bin number for the + configured boundary. The first bin has bin number 1. + " + ::= { mefSoamDmCfgMeasBinEntry 2 } + +mefSoamDmCfgMeasBinLowerBound OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds (us)" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "This object specifies the lower boundary for a + measurement bin. The upper boundary is defined by the next bin + value or infinite for the last bin defined. + The measurement boundary for each measurement bin is to + be larger than the measurement boundary of the preceding + measurement bin. By default, the next bin is set to 5000us larger + than the lower bin boundary. + + The values in a bin boundary object represents the time range + used to segregate delay data into the appropriate statistical + data bin. For five bins with default values, each bin has the + following time range: + + bin 1 = 0, range is 0us <= measurement < 5,000us + bin 2 = 5000, range is 5,000us <= measurement < 10,000us + bin 3 = 10000, range is 10,000us <= measurement < 15,000us + bin 4 = 15000, range is 15,000us <= measurement < 20,000us + bin 5 = 20000, range is 20,000us <= measurement < infinity + + The first bin boundary (mefSoamDmCfgBinNumber set to 1) always contains + the value of 0. Attempting to write a non-zero value to this bin will + result in an error. + " + REFERENCE + "[MEF SOAM-PM] R33, R35, D17" + ::= { mefSoamDmCfgMeasBinEntry 3 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Measured Statistic Table +-- ***************************************************************************** + +mefSoamDmMeasuredStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmMeasuredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This object contains the last measured results for a SOAM Delay + Measurement session. + + Each row in the table represents a Delay Measurement session for + the defined MEP. This table uses four indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific DM session on the selected MEP. + + Instances of this managed object are created automatically + by the SNMP Agent when the Delay Measurement session is running. + + Each object in this table applies only if the corresponding bit is set in + mefSoamDmCfgMeasurementEnable. + + The objects in this table do not need to be persistent upon reboot or restart + of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, D18" + ::= { mefSoamPmDmObjects 3 } + +mefSoamDmMeasuredStatsEntry OBJECT-TYPE + SYNTAX MefSoamDmMeasuredStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmMeasuredStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex + } + ::= { mefSoamDmMeasuredStatsTable 1 } + +MefSoamDmMeasuredStatsEntry ::= SEQUENCE { + mefSoamDmMeasuredStatsFrameDelayTwoWay Unsigned32, + mefSoamDmMeasuredStatsFrameDelayForward Unsigned32, + mefSoamDmMeasuredStatsFrameDelayBackward Unsigned32, + mefSoamDmMeasuredStatsIfdvTwoWay Unsigned32, + mefSoamDmMeasuredStatsIfdvForward Unsigned32, + mefSoamDmMeasuredStatsIfdvBackward Unsigned32 +} + +mefSoamDmMeasuredStatsFrameDelayTwoWay OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the two-way frame delay calculated by this + MEP from the last received SOAM PDU. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 1 } + +mefSoamDmMeasuredStatsFrameDelayForward OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the frame delay in the forward direction + calculated by this MEP from the last received SOAM PDU. The value of this + object may not be accurate in the absence of sufficiently precise clock + synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 2 } + +mefSoamDmMeasuredStatsFrameDelayBackward OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the frame delay in the backward direction + calculated by this MEP from the last received SOAM PDU. The value of this + object may not be accurate in the absence of sufficiently precise clock + synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 3 } + +mefSoamDmMeasuredStatsIfdvTwoWay OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the last two-way inter-frame delay + interval calculated by this MEP. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 4 } + +mefSoamDmMeasuredStatsIfdvForward OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the last one-way inter-frame delay + interval in the forward direction calculated by this MEP. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 5 } + +mefSoamDmMeasuredStatsIfdvBackward OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the last one-way inter-frame delay + interval in the backward direction calculated by this MEP. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmMeasuredStatsEntry 6 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Current Statistic Table +-- ***************************************************************************** + +mefSoamDmCurrentStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmCurrentStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the results for the current Measurement + Interval in a SOAM Delay Measurement session gathered during the interval + indicated by mefSoamLmCfgMeasurementInterval. + + A row in this table is created automatically + by the SNMP Agent when the Delay Measurement session is configured. + + Each row in the table represents the current statistics for a Delay + Measurement session for the defined MEP. This table uses four indices. + The first three indices are the indices of the Maintenance Domain, MaNet, + and MEP tables. The fourth index is the specific DM session on the + selected MEP. There can be more than one DM session per MEP. + + The objects in this table apply regardless of the value of + mefSoamDmCfgType unless otherwise specified in the object description. + Backward and two-way statistic objects are undefined if mefSoamDmCfgType + is dm1DmRx. + + Except for mefSoamDmCurrentStatsIndex, mefSoamDmCurrentStatsStartTime + mefSoamDmCurrentStatsElapsedTime and mefSoamDmCurrentStatsSuspect, + each object in this table applies only if the corresponding bit is set in + mefSoamDmCfgMeasurementEnable. + + The objects in this table do not need to be persistent upon reboot or + restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, D9, D18" + ::= { mefSoamPmDmObjects 4 } + +mefSoamDmCurrentStatsEntry OBJECT-TYPE + SYNTAX MefSoamDmCurrentStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmCurrentStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex + } + ::= { mefSoamDmCurrentStatsTable 1 } + +MefSoamDmCurrentStatsEntry ::= SEQUENCE { + mefSoamDmCurrentStatsIndex Unsigned32, + mefSoamDmCurrentStatsStartTime DateAndTime, + mefSoamDmCurrentStatsElapsedTime TimeInterval, + mefSoamDmCurrentStatsSuspect TruthValue, + mefSoamDmCurrentStatsFrameDelayTwoWayMin Unsigned32, + mefSoamDmCurrentStatsFrameDelayTwoWayMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayTwoWayAvg Unsigned32, + mefSoamDmCurrentStatsFrameDelayForwardMin Unsigned32, + mefSoamDmCurrentStatsFrameDelayForwardMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayForwardAvg Unsigned32, + mefSoamDmCurrentStatsFrameDelayBackwardMin Unsigned32, + mefSoamDmCurrentStatsFrameDelayBackwardMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayBackwardAvg Unsigned32, + mefSoamDmCurrentStatsIfdvForwardMin Unsigned32, + mefSoamDmCurrentStatsIfdvForwardMax Unsigned32, + mefSoamDmCurrentStatsIfdvForwardAvg Unsigned32, + mefSoamDmCurrentStatsIfdvBackwardMin Unsigned32, + mefSoamDmCurrentStatsIfdvBackwardMax Unsigned32, + mefSoamDmCurrentStatsIfdvBackwardAvg Unsigned32, + mefSoamDmCurrentStatsIfdvTwoWayMin Unsigned32, + mefSoamDmCurrentStatsIfdvTwoWayMax Unsigned32, + mefSoamDmCurrentStatsIfdvTwoWayAvg Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeForwardMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeForwardAvg Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeBackwardMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax Unsigned32, + mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg Unsigned32, + mefSoamDmCurrentStatsSoamPdusSent Gauge32, + mefSoamDmCurrentStatsSoamPdusReceived Gauge32 +} + +mefSoamDmCurrentStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index for the current Measurement Interval for this + PM session. This value will become the value for + mefSoamDmHistoryStatsIndex once the Measurement Interval + is completed. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. + " + ::= { mefSoamDmCurrentStatsEntry 1 } + +mefSoamDmCurrentStatsStartTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval started. + " + REFERENCE + "[MEF SOAM-PM] R22, R66, R100" + ::= { mefSoamDmCurrentStatsEntry 2 } + +mefSoamDmCurrentStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the current Measurement Interval has been running, in 0.01 + seconds. + " + REFERENCE + "[MEF SOAM-PM] R24, R66, R100" + ::= { mefSoamDmCurrentStatsEntry 3 } + +mefSoamDmCurrentStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is to be set to false at the start of a measurement + interval. It is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service +" + REFERENCE + "[MEF SOAM-PM] R39, R40, R41" + ::= { mefSoamDmCurrentStatsEntry 4 } + +mefSoamDmCurrentStatsFrameDelayTwoWayMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 5 } + +mefSoamDmCurrentStatsFrameDelayTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 6 } + +mefSoamDmCurrentStatsFrameDelayTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 7 } + +mefSoamDmCurrentStatsFrameDelayForwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R67, R101" + ::= { mefSoamDmCurrentStatsEntry 8 } + +mefSoamDmCurrentStatsFrameDelayForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R67, R101" + ::= { mefSoamDmCurrentStatsEntry 9 } + +mefSoamDmCurrentStatsFrameDelayForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R67, R101" + ::= { mefSoamDmCurrentStatsEntry 10 } + +mefSoamDmCurrentStatsFrameDelayBackwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R67" + ::= { mefSoamDmCurrentStatsEntry 11 } + +mefSoamDmCurrentStatsFrameDelayBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R67" + ::= { mefSoamDmCurrentStatsEntry 12 } + +mefSoamDmCurrentStatsFrameDelayBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R67" + ::= { mefSoamDmCurrentStatsEntry 13 } + +mefSoamDmCurrentStatsIfdvForwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 14 } + +mefSoamDmCurrentStatsIfdvForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 15 } + +mefSoamDmCurrentStatsIfdvForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 16 } + +mefSoamDmCurrentStatsIfdvBackwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 17 } + +mefSoamDmCurrentStatsIfdvBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 18 } + +mefSoamDmCurrentStatsIfdvBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 19 } + +mefSoamDmCurrentStatsIfdvTwoWayMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmCurrentStatsEntry 20 } + +mefSoamDmCurrentStatsIfdvTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmCurrentStatsEntry 21 } + +mefSoamDmCurrentStatsIfdvTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmCurrentStatsEntry 22 } + +mefSoamDmCurrentStatsFrameDelayRangeForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay range + in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 23 } + +mefSoamDmCurrentStatsFrameDelayRangeForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay range + in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 24 } + +mefSoamDmCurrentStatsFrameDelayRangeBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay range + in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 25 } + +mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay range + in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmCurrentStatsEntry 26 } + +mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way frame delay range + calculated by this MEP for this Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmCurrentStatsEntry 27 } + +mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way frame delay range + calculated by this MEP for this Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmCurrentStatsEntry 28 } + +mefSoamDmCurrentStatsSoamPdusSent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM PDUs sent + during this Measurement Interval. + + This object applies when mefSoamDmCfgType is dmDmm or dm1DmTx and + is undefined if mefSoamDmCfgType is dm1DmRx. It indicates the + number of DMM or 1DM SOAM frames transmitted. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 29 } + +mefSoamDmCurrentStatsSoamPdusReceived OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM + PDUs received in this Measurement Interval. + + This object indicates the number of DMR and 1DM SOAM frames + received. This object applies when mefSoamDmCfgType is dmDmm or + dm1DmRx and is undefined if mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmCurrentStatsEntry 30 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Current Bin Statistic Table +-- ***************************************************************************** + +mefSoamDmCurrentStatsBinsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmCurrentStatsBinsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the result bins for the current Measurement + Interval in a SOAM Delay Measurement session. + + Each row in the table represents the current bin statistics for a + Delay Measurement session for the defined MEP. This table uses six + indices. The first three indices are the indices of the Maintenance + Domain, MaNet, and MEP tables. The fourth index is the specific DM + session on the selected MEP. The fifth index indicates bin type and + the sixth indicates the specific bin number. + + A row in this table is created automatically by the SNMP Agent when + the Delay Measurement session is configured and the bin counter value + is set to 0. + + The objects in this table are ignored if mefSoamDmCfgType is 1DmTx. + + This table applies only if the corresponding bit is set in + mefSoamDmCfgMeasurementEnable. + + The objects in this table do not need to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, D9" + ::= { mefSoamPmDmObjects 5 } + +mefSoamDmCurrentStatsBinsEntry OBJECT-TYPE + SYNTAX MefSoamDmCurrentStatsBinsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmCurrentStatsBinsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex, + mefSoamDmCfgMeasBinType, + mefSoamDmCfgMeasBinNumber + } + ::= { mefSoamDmCurrentStatsBinsTable 1 } + +MefSoamDmCurrentStatsBinsEntry ::= SEQUENCE { + mefSoamDmCurrentStatsBinsCounter Gauge32 +} + +mefSoamDmCurrentStatsBinsCounter OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of completed + measurements initiated in this Measurement Interval whose value + falls within the range specified for this bin (that is, greater + than or equal to the measurement boundary for the bin, and + (unless the bin is the last bin) less than the measurement + boundary for the following bin. + " + REFERENCE + "[MEF SOAM-PM] R66, R67, R100, R101" + ::= { mefSoamDmCurrentStatsBinsEntry 1 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement History Statistic Table +-- ***************************************************************************** + +mefSoamDmHistoryStatsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmHistoryStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the results for history Measurement + Intervals in a SOAM Delay Measurement session. + + Rows of this table are created automatically + by the SNMP Agent when the Delay Measurement session is running and a + Measurement Interval is completed. + + Each row in the table represents the Measurement Interval history + statistics for a Delay Measurement session for the defined MEP. This + table uses five indices. The first three indices are the indices of + the Maintenance Domain, MaNet, and MEP tables. The fourth index is the + specific DM session on the selected MEP. The fifth index is the + Measurement Interval. + + At least 32 completed Measurement Intervals are to be supported. 96 + completed Measurement Intervals are recommended to be supported. If + there are at least 32 rows in the table and a new Measurement Interval + completes and a new row is to be added to the table, the oldest completed + Measurement Interval can be deleted (row deletion). If the measurement + interval is other than 15 minutes then a minimum of 8 hours of + completed Measurement Intervals are to be supported and 24 hours are + recommended to be supported. + + The objects in this table apply regardless of the value of + mefSoamDmCfgType unless otherwise specified in the object description. + Backward and two-way statistic objects are undefined if mefSoamDmCfgType + is dm1DmRx. + + Except for mefSoamDmHistoryStatsIndex, mefSoamDmHistoryStatsEndTime, + mefSoamDmHistoryStatsElapsedTime and mefSoamDmHistoryStatsSuspect, + each object in this table applies only if the corresponding bit is set in + mefSoamDmCfgMeasurementEnable. + + The rows and objects in this table are to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, R21, D8, R25" + ::= { mefSoamPmDmObjects 6 } + +mefSoamDmHistoryStatsEntry OBJECT-TYPE + SYNTAX MefSoamDmHistoryStatsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmHistoryStatsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex, + mefSoamDmHistoryStatsIndex + } + ::= { mefSoamDmHistoryStatsTable 1 } + +MefSoamDmHistoryStatsEntry ::= SEQUENCE { + mefSoamDmHistoryStatsIndex Unsigned32, + mefSoamDmHistoryStatsEndTime DateAndTime, + mefSoamDmHistoryStatsElapsedTime TimeInterval, + mefSoamDmHistoryStatsSuspect TruthValue, + mefSoamDmHistoryStatsFrameDelayTwoWayMin Unsigned32, + mefSoamDmHistoryStatsFrameDelayTwoWayMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayTwoWayAvg Unsigned32, + mefSoamDmHistoryStatsFrameDelayForwardMin Unsigned32, + mefSoamDmHistoryStatsFrameDelayForwardMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayForwardAvg Unsigned32, + mefSoamDmHistoryStatsFrameDelayBackwardMin Unsigned32, + mefSoamDmHistoryStatsFrameDelayBackwardMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayBackwardAvg Unsigned32, + mefSoamDmHistoryStatsIfdvForwardMin Unsigned32, + mefSoamDmHistoryStatsIfdvForwardMax Unsigned32, + mefSoamDmHistoryStatsIfdvForwardAvg Unsigned32, + mefSoamDmHistoryStatsIfdvBackwardMin Unsigned32, + mefSoamDmHistoryStatsIfdvBackwardMax Unsigned32, + mefSoamDmHistoryStatsIfdvBackwardAvg Unsigned32, + mefSoamDmHistoryStatsIfdvTwoWayMin Unsigned32, + mefSoamDmHistoryStatsIfdvTwoWayMax Unsigned32, + mefSoamDmHistoryStatsIfdvTwoWayAvg Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeForwardMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeForwardAvg Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeBackwardMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeBackwardAvg Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeTwoWayMax Unsigned32, + mefSoamDmHistoryStatsFrameDelayRangeTwoWayAvg Unsigned32, + mefSoamDmHistoryStatsSoamPdusSent Gauge32, + mefSoamDmHistoryStatsSoamPdusReceived Gauge32 +} + +mefSoamDmHistoryStatsIndex OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index for the Measurement Interval within this + PM session. + + Measurement Interval indexes are assigned sequentially by + the SNMP Agent. The first Measurement Interval that occurs after + the session is started is assigned index 1. + + Referential integrity is necessary, i.e., the index needs to be + persistent upon a reboot or restart of a device. The index + is never reused while this session is active until it wraps to zero. + The index value keeps increasing up to that time. + " + ::= { mefSoamDmHistoryStatsEntry 1 } + +mefSoamDmHistoryStatsEndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time that the Measurement Interval ended. + " + REFERENCE + "[MEF SOAM-PM] R23, R66, R100" + ::= { mefSoamDmHistoryStatsEntry 2 } + +mefSoamDmHistoryStatsElapsedTime OBJECT-TYPE + SYNTAX TimeInterval + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The length of time that the Measurement Interval ran for, + in 0.01 seconds. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 3 } + +mefSoamDmHistoryStatsSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Whether the Measurement Interval has been marked as suspect. + + The object is set to true when there is a discontinuity in the + performance measurements during the Measurement Interval. Conditions + for a discontinuity include, but are not limited to the following: + + 1 - The local time-of-day clock is adjusted by at least 10 seconds + 2 - The conducting of a performance measurement is halted before the + current Measurement Interval is completed + 3 - A local test, failure, or reconfiguration that disrupts service + " + REFERENCE + "[MEF SOAM-PM] R39, R40, R41, R42" + ::= { mefSoamDmHistoryStatsEntry 4 } + +mefSoamDmHistoryStatsFrameDelayTwoWayMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 5 } + +mefSoamDmHistoryStatsFrameDelayTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 6 } + +mefSoamDmHistoryStatsFrameDelayTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way frame delay + calculated by this MEP for this Measurement Interval. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 7 } + +mefSoamDmHistoryStatsFrameDelayForwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 8 } + +mefSoamDmHistoryStatsFrameDelayForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 9 } + +mefSoamDmHistoryStatsFrameDelayForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay + in the forward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 10 } + +mefSoamDmHistoryStatsFrameDelayBackwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 11 } + +mefSoamDmHistoryStatsFrameDelayBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 12 } + +mefSoamDmHistoryStatsFrameDelayBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way frame delay + in the backward direction calculated by this MEP for this + Measurement Interval. The value of this object may not be accurate + in the absence of sufficiently precise clock synchronization. + + This object is undefined is mefSoamDmCfgType is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 13 } + +mefSoamDmHistoryStatsIfdvForwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 14 } + +mefSoamDmHistoryStatsIfdvForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 15 } + +mefSoamDmHistoryStatsIfdvForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way inter-frame delay + interval in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 16 } + +mefSoamDmHistoryStatsIfdvBackwardMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 17 } + +mefSoamDmHistoryStatsIfdvBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 18 } + +mefSoamDmHistoryStatsIfdvBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way inter-frame delay + interval in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 19 } + +mefSoamDmHistoryStatsIfdvTwoWayMin OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the minimum two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmHistoryStatsEntry 20 } + +mefSoamDmHistoryStatsIfdvTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmHistoryStatsEntry 21 } + +mefSoamDmHistoryStatsIfdvTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way inter-frame delay + interval calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmHistoryStatsEntry 22 } + +mefSoamDmHistoryStatsFrameDelayRangeForwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way Frame Delay Range + in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 23 } + +mefSoamDmHistoryStatsFrameDelayRangeForwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way Frame Delay Range + in the forward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 24 } + +mefSoamDmHistoryStatsFrameDelayRangeBackwardMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum one-way Frame Delay Range + in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 25 } + +mefSoamDmHistoryStatsFrameDelayRangeBackwardAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average one-way Frame Delay Range + in the backward direction calculated by this MEP for this + Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + REFERENCE + "[MEF SOAM-PM] R66" + ::= { mefSoamDmHistoryStatsEntry 26 } + +mefSoamDmHistoryStatsFrameDelayRangeTwoWayMax OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the maximum two-way Frame Delay Range + calculated by this MEP for this Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmHistoryStatsEntry 27 } + +mefSoamDmHistoryStatsFrameDelayRangeTwoWayAvg OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the average two-way Frame Delay Range + calculated by this MEP for this Measurement Interval. + + The value of this object is undefined when mefSoamDmCfgType + is dm1DmTx or dm1DmRx. + " + ::= { mefSoamDmHistoryStatsEntry 28 } + +mefSoamDmHistoryStatsSoamPdusSent OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM PDUs sent + during this Measurement Interval. + + This object applies when mefSoamDmCfgType is dmDmm or dm1DmTx and + is undefined if mefSoamDmCfgType is dm1DmRx. It indicates the + number of DMM or 1DM SOAM frames transmitted. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 29 } + +mefSoamDmHistoryStatsSoamPdusReceived OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of SOAM + PDUs received in this Measurement Interval. + + This object indicates the number of DMR and 1DM SOAM frames + received. This object applies when mefSoamDmCfgType is dmDmm or + dm1DmRx and is undefined if mefSoamDmCfgType is dm1DmTx. + " + REFERENCE + "[MEF SOAM-PM] R66, R100" + ::= { mefSoamDmHistoryStatsEntry 30 } + +-- ***************************************************************************** +-- Ethernet Delay Measurement Bin History Statistic Table +-- ***************************************************************************** + +mefSoamDmHistoryStatsBinsTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmHistoryStatsBinsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the result bins for the history Measurement + Intervals in a SOAM Delay Measurement session. + + Rows of this table are created automatically + by the SNMP Agent when the Delay Measurement session is running and a + Measurement Interval is completed. + + Each row in the table represents the Measurement Interval history + statistics for a specific bin in a Delay Measurement session for the + defined MEP. This table uses seven indices. The first three indices + are the indices of the Maintenance Domain, MaNet, and MEP tables. The + fourth index is the specific DM session on the selected MEP. The + fifth index is the Measurement Interval. The sixth index is the + specific bin type. The seventh index is the specific bin number. + + Rows in this table pertaining to a given Measurement Interval are + deleted when (and only when) the corresponding row in the + mefSoamDmHistoryStatsTable is deleted. + + The objects in this table are ignored if mefSoamDmCfgType is 1DmTx. + + This table applies only if the corresponding bit is set in + mefSoamDmCfgMeasurementEnable. + + The objects in this table need to be persistent upon reboot + or restart of a device. + " + REFERENCE + "[MEF SOAM-PM] R7, R15, R21, D8, R66, R67" + ::= { mefSoamPmDmObjects 7 } + +mefSoamDmHistoryStatsBinsEntry OBJECT-TYPE + SYNTAX MefSoamDmHistoryStatsBinsEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmHistoryStatsBinsTable" + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex, + mefSoamDmHistoryStatsIndex, + mefSoamDmCfgMeasBinType, + mefSoamDmCfgMeasBinNumber + } + ::= { mefSoamDmHistoryStatsBinsTable 1 } + +MefSoamDmHistoryStatsBinsEntry ::= SEQUENCE { + mefSoamDmHistoryStatsBinsCounter Gauge32 +} + +mefSoamDmHistoryStatsBinsCounter OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object contains the count of the number of completed + measurements initiated in this Measurement Interval whose value + falls within the range specified for this bin (that is, greater + than or equal to the measurement boundary for the bin, and + (unless the bin is the last bin) less than the measurement + boundary for the following bin. + " + REFERENCE + "[MEF SOAM-PM] R66, R67, R100, R101" + ::= { mefSoamDmHistoryStatsBinsEntry 1 } + +-- ***************************************************************************** +-- Performance Measurement Loss Threshold Configuration Table +-- ***************************************************************************** + +mefSoamLmThresholdCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamLmThresholdCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the list of Loss Measurement configuration threshold + values for LM Performance Monitoring. + + The main purpose of the threshold configuration table is to configure + threshold alarm notifications indicating that a specific performance + metric is not being met. + + Each row in the table represents a Loss Measurement session threshold + set for the defined MEP. This table uses five indices. The first three + indices are the indices of the Maintenance Domain, MaNet, and MEP tables. + The fourth index is the specific LM session on the selected MEP. The + fifth index is the specific threshold set number. + + Rows in this table are not created automatically. A row is created in + this table to set up a threshold set on a configured MEP that has a + configured LM session. + + If two managers try to 'create' the same row at the same time, the first + creation would succeed, the second creation attempt would result in an + error. The second creation attempt would then need to select a new index + value to successfully create a new row. + + An NE needs to support at least one threshold set for NE SOAM PM compliance. A + second threshold set on the NE is desirable. More than two threshold + sets can be configured on the NE if supported on the NE. + + All the objects in the row have a default value that disables the + particular threshold measurement. In order to enable a threshold + measurement the particular bit in the mefSoamLmThresholdCfgEnable object + is to be set to '1' and the selected threshold measurement is to have + a threshold value configured. Non-configured threshold measurements + are disabled by default. + + The writable objects in this table need to be persistent upon reboot + or restart of a device. + " + ::= { mefSoamPmLmObjects 7 } + +mefSoamLmThresholdCfgEntry OBJECT-TYPE + SYNTAX MefSoamLmThresholdCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamLmThresholdCfgTable." + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamLmCfgIndex, + mefSoamLmThresholdCfgIndex + } + ::= {mefSoamLmThresholdCfgTable 1 } + +MefSoamLmThresholdCfgEntry ::= SEQUENCE { + mefSoamLmThresholdCfgIndex Unsigned32, + mefSoamLmThresholdCfgEnable BITS, + mefSoamLmThresholdCfgMeasuredFlrForwardThreshold Unsigned32, + mefSoamLmThresholdCfgMaxFlrForwardThreshold Unsigned32, + mefSoamLmThresholdCfgAvgFlrForwardThreshold Unsigned32, + mefSoamLmThresholdCfgMeasuredFlrBackwardThreshold Unsigned32, + mefSoamLmThresholdCfgMaxFlrBackwardThreshold Unsigned32, + mefSoamLmThresholdCfgAvgFlrBackwardThreshold Unsigned32, + mefSoamLmThresholdCfgForwardHighLossThreshold Unsigned32, + mefSoamLmThresholdCfgForwardConsecutiveHighLossThreshold Unsigned32, + mefSoamLmThresholdCfgBackwardHighLossThreshold Unsigned32, + mefSoamLmThresholdCfgBackwardConsecutiveHighLossThreshold Unsigned32, + mefSoamLmThresholdCfgForwardUnavailCountThreshold Unsigned32, + mefSoamLmThresholdCfgForwardAvailRatioThreshold Unsigned32, + mefSoamLmThresholdCfgBackwardUnavailCountThreshold Unsigned32, + mefSoamLmThresholdCfgBackwardAvailRatioThreshold Unsigned32, + mefSoamLmThresholdCfgRowStatus RowStatus +} + +mefSoamLmThresholdCfgIndex OBJECT-TYPE + SYNTAX Unsigned32(1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the threshold number for the specific LM + threshold entry. + + An index value of '1' needs to be supported. Other index values + can also be supported. + " + ::= { mefSoamLmThresholdCfgEntry 1 } + +mefSoamLmThresholdCfgEnable OBJECT-TYPE + SYNTAX BITS { + bMefSoamLmMeasuredFlrForwardThreshold(0), + bMefSoamLmMaxFlrForwardThreshold(1), + bMefSoamLmAvgFlrForwardThreshold(2), + bMefSoamLmMeasuredFlrBackwardThreshold(3), + bMefSoamLmMaxFlrBackwardThreshold(4), + bMefSoamLmAvgFlrBackwardThreshold(5), + bMefSoamLmForwardHighLossThreshold(6), + bMefSoamLmForwardConsecutiveHighLossThreshold(7), + bMefSoamLmBackwardHighLossThreshold(8), + bMefSoamLmBackwardConsecutiveHighLossThreshold(9), + bMefSoamLmUnavailForwardThreshold(10), + bMefSoamLmAvailRatioForwardThreshold(11), + bMefSoamLmUnavailBackwardThreshold(12), + bMefSoamLmAvailRatioBackwardThreshold(13) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A vector of bits that indicates the type of SOAM LM thresholds + notifications that are enabled. + + A bit set to '1' enables the specific SOAM LM threshold notification + and when the specific counter is enabled and the threshold is crossed a + notification is generated. + + A bit set to '0' disables the specific SOAM LM threshold notification. + + If a particular SOAM LM threshold is not supported the BIT value is + set to '0'. + + bMefSoamLmMeasuredFlrForwardThreshold(0) + Enables/disables measured frame loss forward ratio threshold + notification. The notification is sent immediately when the + mefSoamLmMeasuredStatsForwardFlr value is + greater than or equal to the threshold value. + bMefSoamLmMaxFlrForwardThreshold(1) + Enables/disables maximum frame loss forward ratio threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentStatsForwardMaxFlr value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamLmAvgFlrForwardThreshold(2) + Enables/disables average frame loss forward ratio threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamLmCurrentStatsForwardAvgFlr value is greater + than or equal to the threshold value. + bMefSoamLmMeasuredFlrBackwardThreshold(3) + Enables/disables measured frame loss backward ratio threshold + notification. The notification is sent immediately when the + mefSoamLmMeasuredStatsBackwardFlr value is + greater than or equal to the threshold value. + bMefSoamLmMaxFlrBackwardThreshold(4) + Enables/disables maximum frame loss backward ratio threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentStatsBackwardMaxFlr value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamLmAvgFlrBackwardThreshold(5) + Enables/disables average frame loss backward ratio threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamLmCurrentStatsBackwardAvgFlr value is + greater than or equal to the threshold value. + bMefSoamLmForwardHighLossThreshold(6) + Enables/disables forward high loss threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsForwardHighLoss value is + greater than or equal to the threshold value in a measurement + interval. + bMefSoamLmForwardConsecutiveHighLossThreshold(7) + Enables/disables forward consecutive high loss threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsForwardConsecutiveHighLoss value is + greater than or equal to the threshold value in a measurement + interval. + bMefSoamLmBackwardHighLossThreshold(8) + Enables/disables backward high loss threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsBackwardHighLoss value is + greater than or equal to the threshold value in a measurement + interval. + bMefSoamLmBackwardConsecutiveHighLossThreshold(9) + Enables/disables backward consecutive high loss threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsBackwardConsecutiveHighLoss value is + greater than or equal to the threshold value in a measurement + interval. + bMefSoamLmUnavailForwardThreshold(10) + Enables/disables unavailable forward threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsForwardUnavailable value is + greater than or equal to threshold value in a Measurement Interval. + bMefSoamLmAvailRatioForwardThreshold(11) + Enables/disables availability ratio forward threshold + notification. The notification is sent immediately when the + availability ratio is greater than or equal to threshold value + in a Measurement Interval. The availability ratio can be calculated + from the values of mefSoamLmCurrentAvailStatsForwardAvailable and + mefSoamLmCurrentAvailStatsForwardUnavailable. + bMefSoamLmUnavailBackwardThreshold(12) + Enables/disables unavailable backward threshold + notification. The notification is sent immediately when the + mefSoamLmCurrentAvailStatsBackwardUnavailable value is + greater than or equal to threshold value in a Measurement Interval. + bMefSoamLmAvailRatioBackwardThreshold(13) + Enables/disables availability ratio backward threshold + notification. The notification is sent immediately when the + availability ratio is greater than or equal to threshold value + in a Measurement Interval. The availability ratio can be calculated + from the values of mefSoamLmCurrentAvailStatsBackwardAvailable and + mefSoamLmCurrentAvailStatsBackwardUnavailable. + " + DEFVAL { { } } + ::= { mefSoamLmThresholdCfgEntry 2 } + +mefSoamLmThresholdCfgMeasuredFlrForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measured forward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 3 } + +mefSoamLmThresholdCfgMaxFlrForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum forward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 4 } + +mefSoamLmThresholdCfgAvgFlrForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average forward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 5 } + +mefSoamLmThresholdCfgMeasuredFlrBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measured backward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 6 } + +mefSoamLmThresholdCfgMaxFlrBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum backward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 7 } + +mefSoamLmThresholdCfgAvgFlrBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average backward frame loss ratio + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 100000 } + ::= { mefSoamLmThresholdCfgEntry 8 } + +mefSoamLmThresholdCfgForwardHighLossThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the forward high loss threshold value that + will be used to determine if a threshold notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 9 } + +mefSoamLmThresholdCfgForwardConsecutiveHighLossThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the consecutive forward high loss + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 10 } + +mefSoamLmThresholdCfgBackwardHighLossThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the backward high loss threshold value that + will be used to determine if a threshold notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 11 } + +mefSoamLmThresholdCfgBackwardConsecutiveHighLossThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the consecutive backward high loss + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 12 } + +mefSoamLmThresholdCfgForwardUnavailCountThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the forward unavailability + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 13 } + +mefSoamLmThresholdCfgForwardAvailRatioThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the forward availability/total time + ratio threshold value that will be used to determine if a threshold + notification is generated if the ratio drops below the configured + value. + + The ratio value is expressed as a percent with a value of 0 (ratio + 0.00) through 100000 (ratio 1.00) + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + DEFVAL { 0 } + ::= { mefSoamLmThresholdCfgEntry 14 } + +mefSoamLmThresholdCfgBackwardUnavailCountThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the backward unavailability + threshold value that will be used to determine if a threshold + notification is generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamLmThresholdCfgEntry 15 } + +mefSoamLmThresholdCfgBackwardAvailRatioThreshold OBJECT-TYPE + SYNTAX Unsigned32 (0..100000) + UNITS "milli-percent" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the backward availability/total time + ratio threshold value that will be used to determine if a threshold + notification is generated if the ratio drops below the configured + value. + + The ratio value is expressed as a percent with a value of 0 (ratio + 0.00) through 100000 (ratio 1.00) + + Units are in milli-percent, where 1 indicates 0.001 percent. + " + DEFVAL { 0 } + ::= { mefSoamLmThresholdCfgEntry 16 } + +mefSoamLmThresholdCfgRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of the row. + + The writable columns in a row cannot be changed if the row + is active. All columns are to have a valid value before a row + can be activated. + " + ::= { mefSoamLmThresholdCfgEntry 17 } + +-- ***************************************************************************** +-- Performance Measurement Delay Threshold Configuration Table +-- ***************************************************************************** + +mefSoamDmThresholdCfgTable OBJECT-TYPE + SYNTAX SEQUENCE OF MefSoamDmThresholdCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "This table contains the list of Delay Measurement threshold configuration + values for DM Performance Monitoring. + + The main purpose of the threshold configuration table is to configure + threshold alarm notifications indicating that a specific performance + metric is not being met. + + Each row in the table represents a Delay Measurement session threshold + set for the defined MEP. This table uses five indices. The first three + indices are the indices of the Maintenance Domain, MaNet, and MEP tables. + The fourth index is the specific DM session on the selected MEP. The + fifth index is the specific threshold set number. + + Rows in this table are not created automatically. A row is created in + this table to set up a threshold set on a configured MEP that has a + configured DM session. + + An NE needs to support at least one threshold set for NE SOAM PM compliance. A + second threshold set on the NE is desirable. More than two threshold + sets on the NE can be configured if supported on the NE. + + All the objects in the row have a default value that disables the + particular threshold measurement. In order to enable a threshold + measurement the particular bit in the mefSoamDmThresholdCfgEnable object + is to be set to '1' and the selected threshold measurement is to have + a threshold value configured. Non-configured threshold measurements + are disabled by default. + + The writable objects in this table need to be persistent upon reboot + or restart of a device. + " + ::= { mefSoamPmDmObjects 8 } + +mefSoamDmThresholdCfgEntry OBJECT-TYPE + SYNTAX MefSoamDmThresholdCfgEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The conceptual row of mefSoamDmThresholdCfgTable." + INDEX { + dot1agCfmMdIndex, + dot1agCfmMaIndex, + dot1agCfmMepIdentifier, + mefSoamDmCfgIndex, + mefSoamDmThresholdCfgIndex + } + ::= {mefSoamDmThresholdCfgTable 1 } + +MefSoamDmThresholdCfgEntry ::= SEQUENCE { + mefSoamDmThresholdCfgIndex Unsigned32, + mefSoamDmThresholdCfgEnable BITS, + mefSoamDmThresholdCfgMeasuredFrameDelayTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgMeasuredIfdvTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgMaxIfdvTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgAvgIfdvTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayRangeTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayRangeTwoWayThreshold Unsigned32, + mefSoamDmThresholdCfgMeasuredFrameDelayForwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayForwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayForwardThreshold Unsigned32, + mefSoamDmThresholdCfgMeasuredIfdvForwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxIfdvForwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgIfdvForwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayRangeForwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayRangeForwardThreshold Unsigned32, + mefSoamDmThresholdCfgMeasuredFrameDelayBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgMeasuredIfdvBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxIfdvBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgIfdvBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgMaxFrameDelayRangeBackwardThreshold Unsigned32, + mefSoamDmThresholdCfgAvgFrameDelayRangeBackwardThreshold Unsigned32, + + mefSoamDmThresholdCfgRowStatus RowStatus +} + +mefSoamDmThresholdCfgIndex OBJECT-TYPE + SYNTAX Unsigned32(1..4294967295) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the threshold number for the specific DM + threshold entry. + + An index value of '1' is to be supported. Other index values + can be supported. + " + ::= { mefSoamDmThresholdCfgEntry 1 } + +mefSoamDmThresholdCfgEnable OBJECT-TYPE + SYNTAX BITS { + bMefSoamDmMeasuredFrameDelayTwoWayThreshold(0), + bMefSoamDmMaxFrameDelayTwoWayThreshold(1), + bMefSoamDmAvgFrameDelayTwoWayThreshold(2), + bMefSoamDmMeasuredIfdvTwoWayThreshold(3), + bMefSoamDmMaxIfdvTwoWayThreshold(4), + bMefSoamDmAvgIfdvTwoWayThreshold(5), + bMefSoamDmMaxFrameDelayRangeTwoWayThreshold(6), + bMefSoamDmAvgFrameDelayRangeTwoWayThreshold(7), + bMefSoamDmMeasuredFrameDelayForwardThreshold(8), + bMefSoamDmMaxFrameDelayForwardThreshold(9), + bMefSoamDmAvgFrameDelayForwardThreshold(10), + bMefSoamDmMeasuredIfdvForwardThreshold(11), + bMefSoamDmMaxIfdvForwardThreshold(12), + bMefSoamDmAvgIfdvForwardThreshold(13), + bMefSoamDmMaxFrameDelayRangeForwardThreshold(14), + bMefSoamDmAvgFrameDelayRangeForwardThreshold(15), + bMefSoamDmMeasuredFrameDelayBackwardThreshold(16), + bMefSoamDmMaxFrameDelayBackwardThreshold(17), + bMefSoamDmAvgFrameDelayBackwardThreshold(18), + bMefSoamDmMeasuredIfdvBackwardThreshold(19), + bMefSoamDmMaxIfdvBackwardThreshold(20), + bMefSoamDmAvgIfdvBackwardThreshold(21), + bMefSoamDmMaxFrameDelayRangeBackwardThreshold(22), + bMefSoamDmAvgFrameDelayRangeBackwardThreshold(23) + } + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "A vector of bits that indicates the type of SOAM DM threshold + notifications that are enabled. + + A bit set to '1' enables the specific SOAM DM threshold notification + and when the specific counter is enabled and the threshold is crossed a + notification is generated. + + A bit set to '0' disables the specific SOAM DM threshold notification. + + If a particular SOAM DM threshold is not supported the BIT value is + set to '0'. + + bMefSoamDmMeasuredFrameDelayTwoWayThreshold(0) + Enables/disables measured frame two-way delay threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsFrameDelayTwoWay value is + greater than or equal to threshold value. + bMefSoamDmMaxFrameDelayTwoWayThreshold(1) + Enables/disables maximum frame two-way delay threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayTwoWayMax value is + greater than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgFrameDelayTwoWayThreshold(2) + Enables/disables average frame two-way delay threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayTwoWayAvg value is + greater than or equal to the threshold value. + bMefSoamDmMeasuredIfdvTwoWayThreshold(3) + Enables/disables measured frame IFDV two-way threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsIfdvTwoWay value is greater + than or equal to threshold value. + bMefSoamDmMaxIfdvTwoWayThreshold(4) + Enables/disables maximum frame IFDV two-way threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsIfdvTwoWayMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgIfdvTwoWayThreshold(5) + Enables/disables average frame IFDV two-way threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsIfdvTwoWayAvg value is + greater than or equal to the threshold value. + bMefSoamDmMaxFrameDelayRangeTwoWayThreshold(6) + Enables/disables maximum Frame Delay Range two-way threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgFrameDelayRangeTwoWayThreshold(7) + Enables/disables average Frame Delay Range two-way threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg value is + greater than or equal to the threshold value. + bMefSoamDmMeasuredFrameDelayForwardThreshold(8) + Enables/disables measured forward frame delay threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsFrameDelayForward value is + greater than or equal to threshold value. + bMefSoamDmMaxFrameDelayForwardThreshold(9) + Enables/disables maximum forward frame delay threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayForwardMax value is + greater than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgFrameDelayForwardThreshold(10) + Enables/disables average forward frame delay threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayForwardAvg value is + greater than or equal to the threshold value. + bMefSoamDmMeasuredIfdvForwardThreshold(11) + Enables/disables measured frame IFDV forward threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsIfdvForward value is greater + than or equal to threshold value. + bMefSoamDmMaxIfdvForwardThreshold(12) + Enables/disables maximum frame IFDV forward threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsIfdvForwardMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgIfdvForwardThreshold(13) + Enables/disables average frame IFDV forward threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsIfdvForwardAvg value is + greater than or equal to the threshold value. + bMefSoamDmMaxFrameDelayRangeForwardThreshold(14) + Enables/disables maximum Frame Delay Range forward threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayRangeForwardMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgFrameDelayRangeForwardThreshold(15) + Enables/disables average Frame Delay Range forward threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayRangeForwardAvg value is + greater than or equal to the threshold value. + bMefSoamDmMeasuredFrameDelayBackwardThreshold(16) + Enables/disables measured backward frame delay threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsFrameDelayBackward value is + greater than or equal to threshold value. + bMefSoamDmMaxFrameDelayBackwardThreshold(17) + Enables/disables maximum backward frame delay threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayBackwardMax value is + greater than or equal to threshold value in a + Measurement Interval. + bMefSoamDmAvgFrameDelayBackwardThreshold(18) + Enables/disables average backward frame delay threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayBackwardAvg value is + greater than or equal to the threshold value. + bMefSoamDmMeasuredIfdvBackwardThreshold(19) + Enables/disables measured frame IFDV backward threshold + notification. The notification is sent immediately when the + mefSoamDmMeasuredStatsIfdvBackward value is greater + than or equal to threshold value. + bMefSoamDmMaxIfdvBackwardThreshold(20) + Enables/disables maximum frame IFDV backward threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsIfdvBackwardMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgIfdvBackwardThreshold(21) + Enables/disables average frame IFDV backward threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsIfdvBackwardAvg value is greater + than or equal to the threshold value. + bMefSoamDmMaxFrameDelayRangeBackwardThreshold(22) + Enables/disables maximum Frame Delay Range backward threshold + notification. The notification is sent immediately when the + mefSoamDmCurrentStatsFrameDelayRangeBackwardMax value is greater + than or equal to threshold value in a Measurement Interval. + bMefSoamDmAvgFrameDelayRangeBackwardThreshold(23) + Enables/disables average Frame Delay Range backward threshold + notification. The notification is sent when at the end of a + Measurement Interval if the + mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg value is greater + than or equal to the threshold value. + " + DEFVAL { { } } + ::= { mefSoamDmThresholdCfgEntry 2 } + +mefSoamDmThresholdCfgMeasuredFrameDelayTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement two-way delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 3 } + +mefSoamDmThresholdCfgMaxFrameDelayTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum two-way delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 4 } + +mefSoamDmThresholdCfgAvgFrameDelayTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average two-way delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 5 } + +mefSoamDmThresholdCfgMeasuredIfdvTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement two-way IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 6 } + +mefSoamDmThresholdCfgMaxIfdvTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum two-way IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 7 } + +mefSoamDmThresholdCfgAvgIfdvTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average two-way IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 8 } + +mefSoamDmThresholdCfgMaxFrameDelayRangeTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum two-way Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 9 } + +mefSoamDmThresholdCfgAvgFrameDelayRangeTwoWayThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average two-way Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 10 } + +mefSoamDmThresholdCfgMeasuredFrameDelayForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement forward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 11 } + +mefSoamDmThresholdCfgMaxFrameDelayForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum forward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 12 } + +mefSoamDmThresholdCfgAvgFrameDelayForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average forward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 13 } + +mefSoamDmThresholdCfgMeasuredIfdvForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 14 } + +mefSoamDmThresholdCfgMaxIfdvForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 15 } + +mefSoamDmThresholdCfgAvgIfdvForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 16 } + +mefSoamDmThresholdCfgMaxFrameDelayRangeForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 17 } + +mefSoamDmThresholdCfgAvgFrameDelayRangeForwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 18 } + +mefSoamDmThresholdCfgMeasuredFrameDelayBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement backward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 19 } + +mefSoamDmThresholdCfgMaxFrameDelayBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum backward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 20 } + +mefSoamDmThresholdCfgAvgFrameDelayBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average backward delay threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 21 } + +mefSoamDmThresholdCfgMeasuredIfdvBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the measurement backward IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 22 } + +mefSoamDmThresholdCfgMaxIfdvBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum backward IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 23 } + +mefSoamDmThresholdCfgAvgIfdvBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average backward IFDV threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 24 } + +mefSoamDmThresholdCfgMaxFrameDelayRangeBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the maximum backward Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 25 } + +mefSoamDmThresholdCfgAvgFrameDelayRangeBackwardThreshold OBJECT-TYPE + SYNTAX Unsigned32 + UNITS "microseconds" + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "This object is used to set the average backward Frame Delay Range threshold + value that will be used to determine if a threshold notification is + generated. + " + DEFVAL { 4294967295 } + ::= { mefSoamDmThresholdCfgEntry 26 } + +mefSoamDmThresholdCfgRowStatus OBJECT-TYPE + SYNTAX RowStatus + MAX-ACCESS read-create + STATUS current + DESCRIPTION + "The status of the row. + + The writable columns in a row cannot be changed if the row + is active. All columns are to have a valid value before a row + can be activated. + " + ::= { mefSoamDmThresholdCfgEntry 27 } + +-- ***************************************************************************** +-- Notification Configuration Objects +-- ***************************************************************************** + +mefSoamPmNotificationCfgAlarmInterval OBJECT-TYPE + SYNTAX Unsigned32 (0..60) + UNITS "Seconds" + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A value indicating the shortest time interval in seconds between the + generation of the same notification type per PM session to the list of + notification destinations. An agent generates the first notification + of given type for a given PM session immediately. An agent is not to + generate a second specific notification of the same type for the same + MEP for the same session until the time interval has expired. A value of zero + indicates that all notifications are sent immediately upon detection + of the condition. + " + DEFVAL {5} + ::= { mefSoamPmNotificationCfg 1 } + +mefSoamPmNotificationCfgAlarmEnable OBJECT-TYPE + SYNTAX BITS { + bAvailabilityChangeAlarm(0), + bLmSessionStartStopAlarm(1), + bDmSessionStartStopAlarm(2), + bPmThresholdAboveAlarm(3), + bPmThresholdSetClearAlarm(4) + } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A vector of bits that indicates whether a specific notification is + enabled. + + A bit set to '1' enables the specific notification generation. + + A bit set to '0' disables the specific notification. + + If a particular alarm is not supported the BIT value of the enable/disable + is set to '0'. + + bAvailabilityChangeAlarm(0) enables/disables mefSoamAvailabilityChangeAlarm + bLmSessionStartStopAlarm(1) enables/disables mefSoamLmSessionStartStopAlarm + bDmSessionStartStopAlarm(2) enables/disables mefSoamDmSessionStartStopAlarm + bPmThresholdAboveAlarm(3) enables/disables mefSoamPmThresholdAboveAlarm + bPmThresholdSetClearAlarm(4) enables/disables mefSoamPmThresholdSetClearAlarm + " + DEFVAL { { } } + ::= { mefSoamPmNotificationCfg 2 } + +-- ***************************************************************************** +-- Notification Data Objects +-- ***************************************************************************** + +mefSoamPmNotificationObjDateAndTime OBJECT-TYPE + SYNTAX DateAndTime + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "This object contains the time and date at the time that + the notification event is detected, not the time of the notification + generation. + + This object is used only for notifications. The mechanism to set and keep + current the date and time is not specified. + " + ::= { mefSoamPmNotificationObj 1 } + +mefSoamPmNotificationObjThresholdId OBJECT-TYPE + SYNTAX OBJECT IDENTIFIER + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The Object Identifier of the object that caused the generation of the + notification from the mefSoamLmThresholdEntry or mefSoamDmThresholdEntry. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 2 } + +mefSoamPmNotificationObjThresholdConfig OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The configured threshold value of the object that caused the generation + of the notification. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 3 } + +mefSoamPmNotificationObjThresholdValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The measured value of the object at the time of the generation of the + Notification, from the mefSoamLmMeasuredStatsTable, + mefSoamLmCurrentStatsTable, mefSoamLmCurrentAvailStatsTable, + mefSoamDmMeasuredStatsTable or mefSoamDmCurrentStatsTable. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 4 } + +mefSoamPmNotificationObjSuspect OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The suspect flag for the current Measurement Interval in which the + notification was generated from the mefSoamLmCurrentStatsTable, + mefSoamLmCurrentAvailStatsTable, or mefSoamDmCurrentStatsTable. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 5 } + +mefSoamPmNotificationObjCrossingType OBJECT-TYPE + SYNTAX INTEGER { + aboveAlarm (1), + setAlarm (2), + clearAlarm (3) + } + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The Notification Crossing Type of the object that caused the generation + of the notification from the mefSoamLmThresholdEntry or + mefSoamDmThresholdEntry. + + aboveAlarm(1) indicates that the crossing type alarm was an above + threshold + + setAlarm(2) indicates that the crossing type alarm was a set + threshold + + clearAlarm(3) indicates that the crossing type alarm was a clear + threshold + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 6 } + +mefSoamPmNotificationObjDestinationMep OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The MAC address of the Destination MEP associated the notification found + in either the mefSoamDmCfgTable or mefSoamLmCfgTable. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 7 } + +mefSoamPmNotificationObjPriority OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The CoS priority of the associated notification found + in either the mefSoamDmCfgTable or mefSoamLmCfgTable. + + This object is only used for the notification. + " + ::= { mefSoamPmNotificationObj 8 } + +-- ***************************************************************************** +-- NOTIFICATIONS (TRAPS) +-- ***************************************************************************** + +mefSoamAvailabilityChangeAlarm NOTIFICATION-TYPE + OBJECTS { + mefSoamPmNotificationObjDateAndTime, + mefSoamLmMeasuredStatsAvailForwardStatus, + mefSoamLmMeasuredStatsAvailBackwardStatus, + mefSoamLmMeasuredStatsAvailForwardLastTransitionTime, + mefSoamLmMeasuredStatsAvailBackwardLastTransitionTime, + mefSoamLmCurrentAvailStatsForwardAvailable, + mefSoamLmCurrentAvailStatsForwardUnavailable, + mefSoamLmCurrentAvailStatsBackwardAvailable, + mefSoamLmCurrentAvailStatsBackwardUnavailable, + mefSoamPmNotificationObjDestinationMep, + mefSoamPmNotificationObjPriority + } + STATUS current + DESCRIPTION + "An mefSoamAvailabilityChangeAlarm notification is sent when the state of + mefSoamLmMeasuredStatsAvailForwardStatus or + mefSoamLmMeasuredStatsAvailBackwardStatus changes. + + The management entity that receives the notification can identify + the system from the network source address of the notification, + and can identify the PM session reporting the change + by the indices in the OID + mefSoamLmMeasuredStatsAvailForwardLastTransitionTime, including + dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, and + mefSoamLmCfgIndex. + + An agent is not to generate more than one mefSoamAvailabilityChangeAlarm + 'notification-event' in a given time interval per PM session as + specified by the mefSoamPmNotificationCfgAlarmInterval. A + 'notification-event' is the transmission of a single notification to + a list of notification destinations. + + If additional availability state changes occur within the + mefSoamPmNotificationCfgAlarmInterval period, then notification + generation for these changes are suppressed by the agent until + the current alarm interval expires. At the end of an alarm interval + period, one notification-event is generated if any availability + state changes occurred since the start of the alarm interval period. + In such a case, another alarm interval period is started right away. + " + REFERENCE + "[MEF SOAM-PM] R83, R84" + ::= { mefSoamPmNotifications 1 } + +mefSoamLmSessionStartStopAlarm NOTIFICATION-TYPE + OBJECTS { + mefSoamLmCfgSessionStatus, + mefSoamPmNotificationObjDateAndTime, + mefSoamPmNotificationObjDestinationMep + } + STATUS current + DESCRIPTION + "An mefSoamLmSessionStartStopAlarm notification is sent when the state of + mefSoamLmCfgSessionStatus changes. + + The management entity that receives the notification can identify + the system from the network source address of the notification, + and can identify the individual PM session reporting the start/stop + by the indices in the OID mefSoamLmCfgSessionStatus, including + dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, and + mefSoamLmCfgIndex. + + An agent is not to generate more than one mefSoamLmSessionStartStopAlarm + 'notification-event' in a given time interval per LM session as specified + by the mefSoamPmNotificationCfgAlarmInterval. A 'notification-event' is + the transmission of a single notification to a list of notification + destinations. + + If additional operational state changes occur within the + mefSoamPmNotificationCfgAlarmInterval period, then notification + generation for these changes are be suppressed by the agent until + the current alarm interval expires. At the end of an alarm interval + period, one notification-event is generated if any operational + state changes occurred since the start of the alarm interval period. In + such a case, another alarm interval period is started right away. + " + ::= { mefSoamPmNotifications 2 } + +mefSoamDmSessionStartStopAlarm NOTIFICATION-TYPE + OBJECTS { + mefSoamDmCfgSessionStatus, + mefSoamPmNotificationObjDateAndTime, + mefSoamPmNotificationObjDestinationMep + } + STATUS current + DESCRIPTION + "An mefSoamDmSessionStartStopAlarm notification is sent when the state of + mefSoamDmCfgSessionStatus changes. + + The management entity that receives the notification can identify + the system from the network source address of the notification, + and can identify the individual PM session reporting the start/stop + by the indices in the OID mefSoamDmCfgSessionStatus, including + dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, and + mefSoamDmCfgIndex. + + An agent is not to generate more than one mefSoamDmSessionStartStopAlarm + 'notification-event' in a given time interval per DM session as specified + by mefSoamPmNotificationCfgAlarmInterval. A 'notification-event' is the + transmission of a single notification to a list of notification + destinations. + + If additional operational state changes occur within the + mefSoamPmNotificationCfgAlarmInterval period, then notification generation + for these changes are suppressed by the agent until the current alarm + interval expires. At the end of an alarm interval period, one + notification-event is generated if any operational state changes + occurred since the start of the alarm interval period. In such a case, + another alarm interval period is started right away. + " + ::= { mefSoamPmNotifications 3 } + +mefSoamPmThresholdCrossingAlarm NOTIFICATION-TYPE + OBJECTS { + mefSoamPmNotificationObjCrossingType, + mefSoamPmNotificationObjThresholdId, + mefSoamPmNotificationObjThresholdConfig, + mefSoamPmNotificationObjThresholdValue, + mefSoamPmNotificationObjSuspect, + mefSoamPmNotificationObjDateAndTime, + mefSoamPmNotificationObjDestinationMep + } + STATUS current + DESCRIPTION + "An mefSoamPmThresholdCrossingAlarm notification is sent if the + following conditions are met for a particular type. + + For an aboveAlarm five conditions need to be met: + + a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable + for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; + and + + b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable + or mefSoamDmThresholdCfgTable; and + + c) the threshold crossing type of bPmThresholdAboveAlarm is enabled; + and + + d) the measured value of the parameter exceeds the value configured in + the mefSoamLmThresholdCfgTable for a LM crossing entry or + mefSoamDmThresholdCfgTable for a DM crossing entry for a type of + bPmThresholdAboveAlarm; and + + e) no previous mefSoamPmThresholdCrossingAlarm notifications with type + aboveAlarm have been sent relating to the same threshold in the + mefSoamLmThresholdCfgTable or mefSoamDmThresholdCfgTable and the + same parameter, during this Measurement Interval. + + For a setAlarm five conditions need to be met: + + a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable + for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; + and + + b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable + or mefSoamDmThresholdCfgTable; and + + c) the threshold crossing type of bPmThresholdSetClearAlarm is enabled; + and + + d) the measured value of the parameter exceeds the value configured in + the mefSoamLmThresholdCfgTable for a LM crossing entry or + mefSoamDmThresholdCfgTable for a DM crossing entry for a type of + bPmThresholdSetClearAlarm for the Measurement Interval; and + + e) the previous measured value did not + exceed the value configured in the mefSoamLmThresholdCfgTable for + a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing + entry for a type of bPmThresholdSetClearAlarm. + + For a clearAlarm five conditions need to be met: + + a) measurement of the parameter is enabled via mefSoamLmCfgMeasurementEnable + for a LM crossing or mefSoamDmCfgMeasurementEnable for a DM crossing; + and + + b) the parameter threshold is configured in the mefSoamLmThresholdCfgTable + or mefSoamDmThresholdCfgTable; and + + c) the threshold crossing type of bPmThresholdSetClearAlarm is enabled; + and + + d) the measured value of the parameter did not exceed the value configured + in the mefSoamLmThresholdCfgTable for a LM crossing entry or + mefSoamDmThresholdCfgTable for a DM crossing entry for a type of + bPmThresholdSetClearAlarm for the Measurement Interval; and + + e) the previous measured value did + exceed the value configured in the mefSoamLmThresholdCfgTable for + a LM crossing entry or mefSoamDmThresholdCfgTable for a DM crossing + entry for a type of bPmThresholdSetClearAlarm. + + In the case of thresholds applied to a maximum or average measurement + counter, the previous measured value is the value of the counter at the + end of the preceding Measurement Interval. In the case of thresholds + applied to the last measured value, it is the previous measured value. + + The management entity that receives the notification can identify + the system from the network source address of the notification, + and can identify the LM or DM session reporting the threshold + crossing by the indices in the mefSoamPmNotificationCfgThresholdId object, + including dot1agCfmMdIndex, dot1agCfmMaIndex, dot1agCfmMepIdentifier, + and the mefSoamLmCfgIndex or mefSoamDmCfgIndex. + + An agent is not to generate more than one mefSoamLmThresholdCrossingAlarm + 'notification-event' of a given type per LM or DM session as specified + by mefSoamPmNotificationCfgAlarmInterval. A 'notification-event' is the + transmission of a single notification to a list of notification + destinations. + + If additional threshold crossing events occur within the + mefSoamPmNotificationCfgAlarmInterval period, then notification + generation for these changes are suppressed by the agent until + the current alarm interval expires. At the end of an alarm interval + period, one notification-event is generated if any threshold + crossing events occurred since the start of the alarm interval period. + In such a case, another alarm interval period is started right away. + " + ::= { mefSoamPmNotifications 4 } + +-- ***************************************************************************** +-- SOAM-PM MIB Module - Conformance Information +-- ***************************************************************************** + +mefSoamPmMibCompliances OBJECT IDENTIFIER ::= { mefSoamPmMibConformance 1 } +mefSoamPmMibGroups OBJECT IDENTIFIER ::= { mefSoamPmMibConformance 2 } + +-- ****************************************************************** +-- SOAM-PM MIB Units of conformance +-- ****************************************************************** + +mefSoamPmMepMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamPmMepOperNextIndex, + mefSoamPmMepSlmSingleEndedResponder, + mefSoamPmMepDmSingleEndedResponder + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM PM MEP group." + ::= { mefSoamPmMibGroups 1 } + +mefSoamPmMepOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamPmMepLmSingleEndedResponder + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM PM MEP group." + ::= { mefSoamPmMibGroups 2 } + +mefSoamLmCfgMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCfgType, + mefSoamLmCfgEnabled, + mefSoamLmCfgMeasurementEnable, + mefSoamLmCfgMessagePeriod, + mefSoamLmCfgPriority, + mefSoamLmCfgFrameSize, + mefSoamLmCfgDataPattern, + mefSoamLmCfgMeasurementInterval, + mefSoamLmCfgNumIntervalsStored, + + mefSoamLmCfgDestMacAddress, + mefSoamLmCfgDestMepId, + mefSoamLmCfgDestIsMepId, + + mefSoamLmCfgStartTimeType, + mefSoamLmCfgFixedStartDateAndTime, + mefSoamLmCfgRelativeStartTime, + mefSoamLmCfgStopTimeType, + mefSoamLmCfgFixedStopDateAndTime, + mefSoamLmCfgRelativeStopTime, + mefSoamLmCfgRepetitionTime, + + mefSoamLmCfgAvailabilityMeasurementInterval, + mefSoamLmCfgAvailabilityNumConsecutiveMeasPdus, + mefSoamLmCfgAvailabilityFlrThreshold, + mefSoamLmCfgAvailabilityNumConsecutiveIntervals, + mefSoamLmCfgSessionType, + mefSoamLmCfgSessionStatus, + mefSoamLmCfgHistoryClear, + mefSoamLmCfgRowStatus + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM Configuration group." + ::= { mefSoamPmMibGroups 3 } + +mefSoamLmCfgOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCfgVersion, + mefSoamLmCfgTestTlvIncluded, + mefSoamLmCfgTestTlvPattern, + mefSoamLmCfgAlignMeasurementIntervals, + mefSoamLmCfgAvailabilityNumConsecutiveHighFlr, + mefSoamLmCfgAlignMeasurementOffset + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM Configuration group." + ::= { mefSoamPmMibGroups 4 } + +mefSoamLmMeasuredStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmMeasuredStatsAvailForwardLastTransitionTime, + mefSoamLmMeasuredStatsAvailBackwardLastTransitionTime + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM Measured Stats group." + ::= { mefSoamPmMibGroups 5 } + +mefSoamLmMeasuredStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmMeasuredStatsForwardFlr, + mefSoamLmMeasuredStatsBackwardFlr, + mefSoamLmMeasuredStatsAvailForwardStatus, + mefSoamLmMeasuredStatsAvailBackwardStatus + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM Measured Stats group." + ::= { mefSoamPmMibGroups 6 } + +mefSoamLmCurrentAvailStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCurrentAvailStatsIndex, + mefSoamLmCurrentAvailStatsStartTime, + mefSoamLmCurrentAvailStatsElapsedTime, + mefSoamLmCurrentAvailStatsSuspect, + mefSoamLmCurrentAvailStatsForwardAvailable, + mefSoamLmCurrentAvailStatsBackwardAvailable, + mefSoamLmCurrentAvailStatsForwardUnavailable, + mefSoamLmCurrentAvailStatsBackwardUnavailable + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM Current Availability group." + ::= { mefSoamPmMibGroups 7 } + +mefSoamLmCurrentAvailStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCurrentAvailStatsForwardHighLoss, + mefSoamLmCurrentAvailStatsBackwardHighLoss, + mefSoamLmCurrentAvailStatsForwardConsecutiveHighLoss, + mefSoamLmCurrentAvailStatsBackwardConsecutiveHighLoss, + mefSoamLmCurrentAvailStatsForwardMinFlr, + mefSoamLmCurrentAvailStatsForwardMaxFlr, + mefSoamLmCurrentAvailStatsForwardAvgFlr, + mefSoamLmCurrentAvailStatsBackwardMinFlr, + mefSoamLmCurrentAvailStatsBackwardMaxFlr, + mefSoamLmCurrentAvailStatsBackwardAvgFlr + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM Current Availabilty Stats group." + ::= { mefSoamPmMibGroups 8 } + +mefSoamLmCurrentStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCurrentStatsIndex, + mefSoamLmCurrentStatsStartTime, + mefSoamLmCurrentStatsElapsedTime, + mefSoamLmCurrentStatsSuspect, + mefSoamLmCurrentStatsSoamPdusSent, + mefSoamLmCurrentStatsSoamPdusReceived + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM current statistics group." + ::= { mefSoamPmMibGroups 9 } + +mefSoamLmCurrentStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmCurrentStatsForwardTransmittedFrames, + mefSoamLmCurrentStatsForwardReceivedFrames, + mefSoamLmCurrentStatsBackwardTransmittedFrames, + mefSoamLmCurrentStatsBackwardReceivedFrames, + mefSoamLmCurrentStatsForwardMinFlr, + mefSoamLmCurrentStatsForwardMaxFlr, + mefSoamLmCurrentStatsForwardAvgFlr, + mefSoamLmCurrentStatsBackwardMinFlr, + mefSoamLmCurrentStatsBackwardMaxFlr, + mefSoamLmCurrentStatsBackwardAvgFlr + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM Current Stats group." + ::= { mefSoamPmMibGroups 10 } + +mefSoamLmHistoryAvailStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmHistoryAvailStatsEndTime, + mefSoamLmHistoryAvailStatsElapsedTime, + mefSoamLmHistoryAvailStatsSuspect, + mefSoamLmHistoryAvailStatsForwardAvailable, + mefSoamLmHistoryAvailStatsBackwardAvailable, + mefSoamLmHistoryAvailStatsForwardUnavailable, + mefSoamLmHistoryAvailStatsBackwardUnavailable + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM Availability LM history + statistics group. + " + ::= { mefSoamPmMibGroups 11 } + +mefSoamLmHistoryAvailStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmHistoryAvailStatsForwardHighLoss, + mefSoamLmHistoryAvailStatsBackwardHighLoss, + mefSoamLmHistoryAvailStatsForwardConsecutiveHighLoss, + mefSoamLmHistoryAvailStatsBackwardConsecutiveHighLoss, + mefSoamLmHistoryAvailStatsForwardMinFlr, + mefSoamLmHistoryAvailStatsForwardMaxFlr, + mefSoamLmHistoryAvailStatsForwardAvgFlr, + mefSoamLmHistoryAvailStatsBackwardMinFlr, + mefSoamLmHistoryAvailStatsBackwardMaxFlr, + mefSoamLmHistoryAvailStatsBackwardAvgFlr + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM Availability LM history + statistics group. + " + ::= { mefSoamPmMibGroups 12 } + +mefSoamLmHistoryStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmHistoryStatsEndTime, + mefSoamLmHistoryStatsElapsedTime, + mefSoamLmHistoryStatsSuspect, + mefSoamLmHistoryStatsSoamPdusSent, + mefSoamLmHistoryStatsSoamPdusReceived + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM history statistics group." + ::= { mefSoamPmMibGroups 13 } + +mefSoamLmHistoryStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmHistoryStatsForwardTransmittedFrames, + mefSoamLmHistoryStatsForwardReceivedFrames, + mefSoamLmHistoryStatsBackwardTransmittedFrames, + mefSoamLmHistoryStatsBackwardReceivedFrames, + mefSoamLmHistoryStatsForwardMinFlr, + mefSoamLmHistoryStatsForwardMaxFlr, + mefSoamLmHistoryStatsForwardAvgFlr, + mefSoamLmHistoryStatsBackwardMinFlr, + mefSoamLmHistoryStatsBackwardMaxFlr, + mefSoamLmHistoryStatsBackwardAvgFlr + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM History Stats group." + ::= { mefSoamPmMibGroups 14 } + +mefSoamDmCfgMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCfgType, + mefSoamDmCfgEnabled, + mefSoamDmCfgMeasurementEnable, + mefSoamDmCfgMessagePeriod, + + mefSoamDmCfgPriority, + mefSoamDmCfgFrameSize, + mefSoamDmCfgDataPattern, + mefSoamDmCfgMeasurementInterval, + mefSoamDmCfgNumIntervalsStored, + + mefSoamDmCfgDestMacAddress, + mefSoamDmCfgDestMepId, + mefSoamDmCfgDestIsMepId, + + mefSoamDmCfgStartTimeType, + mefSoamDmCfgFixedStartDateAndTime, + mefSoamDmCfgRelativeStartTime, + mefSoamDmCfgStopTimeType, + mefSoamDmCfgFixedStopDateAndTime, + mefSoamDmCfgRelativeStopTime, + mefSoamDmCfgRepetitionTime, + + mefSoamDmCfgAlignMeasurementIntervals, + mefSoamDmCfgNumMeasBinsPerFrameDelayInterval, + mefSoamDmCfgNumMeasBinsPerInterFrameDelayVariationInterval, + mefSoamDmCfgNumMeasBinsPerFrameDelayRangeInterval, + mefSoamDmCfgSessionType, + mefSoamDmCfgSessionStatus, + mefSoamDmCfgHistoryClear, + mefSoamDmCfgRowStatus + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM configuration group." + ::= { mefSoamPmMibGroups 15 } + +mefSoamDmCfgOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCfgVersion, + mefSoamDmCfgTestTlvIncluded, + mefSoamDmCfgTestTlvPattern, + mefSoamDmCfgSourceMacAddress, + mefSoamDmCfgAlignMeasurementOffset, + mefSoamDmCfgInterFrameDelayVariationSelectionOffset + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM DM Configuration group." + ::= { mefSoamPmMibGroups 16 } + +mefSoamDmCfgMeasBinMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCfgMeasBinLowerBound +} + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM measurement bin configuration + group." + ::= { mefSoamPmMibGroups 17 } + +mefSoamDmMeasuredStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamDmMeasuredStatsFrameDelayTwoWay, + mefSoamDmMeasuredStatsFrameDelayForward, + mefSoamDmMeasuredStatsFrameDelayBackward, + mefSoamDmMeasuredStatsIfdvTwoWay, + mefSoamDmMeasuredStatsIfdvForward, + mefSoamDmMeasuredStatsIfdvBackward + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM DM Measured Stats group." + ::= { mefSoamPmMibGroups 18 } + +mefSoamDmCurrentStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCurrentStatsIndex, + mefSoamDmCurrentStatsStartTime, + mefSoamDmCurrentStatsElapsedTime, + mefSoamDmCurrentStatsSuspect, + mefSoamDmCurrentStatsFrameDelayTwoWayMin, + mefSoamDmCurrentStatsFrameDelayTwoWayMax, + mefSoamDmCurrentStatsFrameDelayTwoWayAvg, + mefSoamDmCurrentStatsFrameDelayForwardMin, + mefSoamDmCurrentStatsFrameDelayForwardMax, + mefSoamDmCurrentStatsFrameDelayForwardAvg, + mefSoamDmCurrentStatsFrameDelayBackwardMin, + mefSoamDmCurrentStatsFrameDelayBackwardMax, + mefSoamDmCurrentStatsFrameDelayBackwardAvg, + mefSoamDmCurrentStatsIfdvForwardMin, + mefSoamDmCurrentStatsIfdvForwardMax, + mefSoamDmCurrentStatsIfdvForwardAvg, + mefSoamDmCurrentStatsIfdvBackwardMin, + mefSoamDmCurrentStatsIfdvBackwardMax, + mefSoamDmCurrentStatsIfdvBackwardAvg, + mefSoamDmCurrentStatsFrameDelayRangeForwardMax, + mefSoamDmCurrentStatsFrameDelayRangeForwardAvg, + mefSoamDmCurrentStatsFrameDelayRangeBackwardMax, + mefSoamDmCurrentStatsFrameDelayRangeBackwardAvg, + mefSoamDmCurrentStatsSoamPdusSent, + mefSoamDmCurrentStatsSoamPdusReceived + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM current statistics group." + ::= { mefSoamPmMibGroups 19 } + +mefSoamDmCurrentStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCurrentStatsIfdvTwoWayMin, + mefSoamDmCurrentStatsIfdvTwoWayMax, + mefSoamDmCurrentStatsIfdvTwoWayAvg, + mefSoamDmCurrentStatsFrameDelayRangeTwoWayMax, + mefSoamDmCurrentStatsFrameDelayRangeTwoWayAvg + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM DM current statistics group." + ::= { mefSoamPmMibGroups 20 } + +mefSoamDmCurrentStatsBinsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmCurrentStatsBinsCounter +} + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM current statistics bin + group." + ::= { mefSoamPmMibGroups 21 } + +mefSoamDmHistoryStatsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmHistoryStatsEndTime, + mefSoamDmHistoryStatsElapsedTime, + mefSoamDmHistoryStatsSuspect, + mefSoamDmHistoryStatsFrameDelayTwoWayMin, + mefSoamDmHistoryStatsFrameDelayTwoWayMax, + mefSoamDmHistoryStatsFrameDelayTwoWayAvg, + mefSoamDmHistoryStatsFrameDelayForwardMin, + mefSoamDmHistoryStatsFrameDelayForwardMax, + mefSoamDmHistoryStatsFrameDelayForwardAvg, + mefSoamDmHistoryStatsFrameDelayBackwardMin, + mefSoamDmHistoryStatsFrameDelayBackwardMax, + mefSoamDmHistoryStatsFrameDelayBackwardAvg, + mefSoamDmHistoryStatsIfdvForwardMin, + mefSoamDmHistoryStatsIfdvForwardMax, + mefSoamDmHistoryStatsIfdvForwardAvg, + mefSoamDmHistoryStatsIfdvBackwardMin, + mefSoamDmHistoryStatsIfdvBackwardMax, + mefSoamDmHistoryStatsIfdvBackwardAvg, + mefSoamDmHistoryStatsFrameDelayRangeForwardMax, + mefSoamDmHistoryStatsFrameDelayRangeForwardAvg, + mefSoamDmHistoryStatsFrameDelayRangeBackwardMax, + mefSoamDmHistoryStatsFrameDelayRangeBackwardAvg, + mefSoamDmHistoryStatsSoamPdusSent, + mefSoamDmHistoryStatsSoamPdusReceived + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM history statistics group." + ::= { mefSoamPmMibGroups 22 } + +mefSoamDmHistoryStatsOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamDmHistoryStatsIfdvTwoWayMin, + mefSoamDmHistoryStatsIfdvTwoWayMax, + mefSoamDmHistoryStatsIfdvTwoWayAvg, + mefSoamDmHistoryStatsFrameDelayRangeTwoWayMax, + mefSoamDmHistoryStatsFrameDelayRangeTwoWayAvg + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM DM history statistics group." + ::= { mefSoamPmMibGroups 23 } + +mefSoamDmHistoryStatsBinsMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmHistoryStatsBinsCounter +} + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM history statistics + bin group." + ::= { mefSoamPmMibGroups 24 } + +mefSoamLmThresholdMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamLmThresholdCfgEnable, + mefSoamLmThresholdCfgMaxFlrForwardThreshold, + mefSoamLmThresholdCfgAvgFlrForwardThreshold, + mefSoamLmThresholdCfgMaxFlrBackwardThreshold, + mefSoamLmThresholdCfgAvgFlrBackwardThreshold, + mefSoamLmThresholdCfgForwardUnavailCountThreshold, + mefSoamLmThresholdCfgForwardAvailRatioThreshold, + mefSoamLmThresholdCfgBackwardUnavailCountThreshold, + mefSoamLmThresholdCfgBackwardAvailRatioThreshold, + mefSoamLmThresholdCfgRowStatus + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM LM threshold group." + ::= { mefSoamPmMibGroups 25 } + +mefSoamLmThresholdOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamLmThresholdCfgForwardHighLossThreshold, + mefSoamLmThresholdCfgForwardConsecutiveHighLossThreshold, + mefSoamLmThresholdCfgBackwardHighLossThreshold, + mefSoamLmThresholdCfgBackwardConsecutiveHighLossThreshold, + mefSoamLmThresholdCfgMeasuredFlrForwardThreshold, + mefSoamLmThresholdCfgMeasuredFlrBackwardThreshold + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM LM Threshold group." + ::= { mefSoamPmMibGroups 26 } + +mefSoamDmThresholdMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamDmThresholdCfgEnable, + mefSoamDmThresholdCfgMaxFrameDelayTwoWayThreshold, + mefSoamDmThresholdCfgAvgFrameDelayTwoWayThreshold, + mefSoamDmThresholdCfgMaxFrameDelayForwardThreshold, + mefSoamDmThresholdCfgAvgFrameDelayForwardThreshold, + mefSoamDmThresholdCfgMaxIfdvForwardThreshold, + mefSoamDmThresholdCfgAvgIfdvForwardThreshold, + mefSoamDmThresholdCfgMaxFrameDelayRangeForwardThreshold, + mefSoamDmThresholdCfgAvgFrameDelayRangeForwardThreshold, + mefSoamDmThresholdCfgMaxFrameDelayBackwardThreshold, + mefSoamDmThresholdCfgAvgFrameDelayBackwardThreshold, + mefSoamDmThresholdCfgMaxIfdvBackwardThreshold, + mefSoamDmThresholdCfgAvgIfdvBackwardThreshold, + mefSoamDmThresholdCfgMaxFrameDelayRangeBackwardThreshold, + mefSoamDmThresholdCfgAvgFrameDelayRangeBackwardThreshold, + mefSoamDmThresholdCfgRowStatus + } + STATUS current + DESCRIPTION + "Mandatory objects for the Service OAM DM threshold group." + ::= { mefSoamPmMibGroups 27 } + +mefSoamDmThresholdOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamDmThresholdCfgMeasuredIfdvTwoWayThreshold, + mefSoamDmThresholdCfgMeasuredFrameDelayTwoWayThreshold, + mefSoamDmThresholdCfgMeasuredFrameDelayForwardThreshold, + mefSoamDmThresholdCfgMeasuredIfdvForwardThreshold, + mefSoamDmThresholdCfgMeasuredFrameDelayBackwardThreshold, + mefSoamDmThresholdCfgMeasuredIfdvBackwardThreshold, + mefSoamDmThresholdCfgMaxIfdvTwoWayThreshold, + mefSoamDmThresholdCfgAvgIfdvTwoWayThreshold, + mefSoamDmThresholdCfgMaxFrameDelayRangeTwoWayThreshold, + mefSoamDmThresholdCfgAvgFrameDelayRangeTwoWayThreshold + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM DM threshold group." + ::= { mefSoamPmMibGroups 28 } + +mefSoamPmNotificationsMandatoryGroup NOTIFICATION-GROUP + NOTIFICATIONS { + mefSoamAvailabilityChangeAlarm, + mefSoamLmSessionStartStopAlarm, + mefSoamDmSessionStartStopAlarm + } + STATUS current + DESCRIPTION + "Mandatory notifications for the SOAM PM Notifications group." + ::= { mefSoamPmMibGroups 29 } + +mefSoamPmNotificationsOptionalGroup NOTIFICATION-GROUP + NOTIFICATIONS { + mefSoamPmThresholdCrossingAlarm + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM PM Notifications group." + ::= { mefSoamPmMibGroups 30 } + +mefSoamPmNotificationCfgMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamPmNotificationCfgAlarmInterval, + mefSoamPmNotificationCfgAlarmEnable + } + STATUS current + DESCRIPTION + "Mandatory objects for the SOAM PM Notification Configuration group." + ::= { mefSoamPmMibGroups 31 } + +mefSoamPmNotificationObjMandatoryGroup OBJECT-GROUP + OBJECTS { + mefSoamPmNotificationObjDateAndTime, + mefSoamPmNotificationObjSuspect, + mefSoamPmNotificationObjDestinationMep, + mefSoamPmNotificationObjPriority + + } + STATUS current + DESCRIPTION + "Mandatory objects for the SOAM PM Notification Object group." + ::= { mefSoamPmMibGroups 32 } + +mefSoamPmNotificationObjOptionalGroup OBJECT-GROUP + OBJECTS { + mefSoamPmNotificationObjThresholdConfig, + mefSoamPmNotificationObjThresholdId, + mefSoamPmNotificationObjThresholdValue, + mefSoamPmNotificationObjCrossingType + } + STATUS current + DESCRIPTION + "Optional objects for the Service OAM PM Notifications group." + ::= { mefSoamPmMibGroups 33 } + +-- ****************************************************************** +-- SOAM-PM MIB Module Compliance statements +-- ****************************************************************** + +mefSoamPmMibCompliance MODULE-COMPLIANCE + STATUS current + DESCRIPTION "The compliance statement for the Ethernet Service OAM PM MIB." + MODULE + MANDATORY-GROUPS { + mefSoamPmMepMandatoryGroup, + mefSoamLmCfgMandatoryGroup, + mefSoamLmMeasuredStatsMandatoryGroup, + mefSoamLmCurrentAvailStatsMandatoryGroup, + mefSoamLmCurrentStatsMandatoryGroup, + mefSoamLmHistoryAvailStatsMandatoryGroup, + mefSoamLmHistoryStatsMandatoryGroup, + mefSoamDmCfgMandatoryGroup, + mefSoamDmCfgMeasBinMandatoryGroup, + mefSoamDmCurrentStatsMandatoryGroup, + mefSoamDmCurrentStatsBinsMandatoryGroup, + mefSoamDmHistoryStatsMandatoryGroup, + mefSoamDmHistoryStatsBinsMandatoryGroup, + mefSoamLmThresholdMandatoryGroup, + mefSoamDmThresholdMandatoryGroup, + mefSoamPmNotificationsMandatoryGroup, + mefSoamPmNotificationCfgMandatoryGroup, + mefSoamPmNotificationObjMandatoryGroup + } + + GROUP mefSoamPmMepOptionalGroup + DESCRIPTION "The mefSoamPmMepOptionalGroup is an optional requirement." + + GROUP mefSoamLmCfgOptionalGroup + DESCRIPTION "The mefSoamLmCfgOptionalGroup is an optional requirement." + + GROUP mefSoamLmMeasuredStatsOptionalGroup + DESCRIPTION "The mefSoamLmMeasuredStatsOptionalGroup is an optional requirement." + + GROUP mefSoamLmCurrentAvailStatsOptionalGroup + DESCRIPTION "The mefSoamLmCurrentAvailStatsOptionalGroup is an optional + requirement." + + GROUP mefSoamLmCurrentStatsOptionalGroup + DESCRIPTION "The mefSoamLmCurrentStatsOptionalGroup is an optional requirement." + + GROUP mefSoamLmHistoryAvailStatsOptionalGroup + DESCRIPTION "The mefSoamLmCurrentStatsOptionalGroup is an optional requirement." + + GROUP mefSoamLmHistoryStatsOptionalGroup + DESCRIPTION "The mefSoamLmHistoryStatsOptionalGroup is an optional requirement." + + GROUP mefSoamDmCfgOptionalGroup + DESCRIPTION "The mefSoamDmCfgOptionalGroup is an optional requirement." + + GROUP mefSoamDmMeasuredStatsOptionalGroup + DESCRIPTION "The mefSoamDmMeasuredStatsOptionalGroup is an optional requirement." + + GROUP mefSoamDmCurrentStatsOptionalGroup + DESCRIPTION "The mefSoamDmCurrentStatsOptionalGroup is an optional requirement." + + GROUP mefSoamDmHistoryStatsOptionalGroup + DESCRIPTION "The mefSoamDmHistoryStatsOptionalGroup is an optional requirement." + + GROUP mefSoamLmThresholdOptionalGroup + DESCRIPTION "The mefSoamLmThresholdOptionalGroup is an optional requirement." + + GROUP mefSoamDmThresholdOptionalGroup + DESCRIPTION "The mefSoamDmThresholdOptionalGroup is an optional requirement." + + GROUP mefSoamPmNotificationsOptionalGroup + DESCRIPTION "The mefSoamPmNotificationsOptionalGroup is an optional requirement." + + GROUP mefSoamPmNotificationObjOptionalGroup + DESCRIPTION "The mefSoamPmNotificationObjOptionalGroup is an optional + requirement." + ::= { mefSoamPmMibCompliances 1 } + +END -- cgit v1.2.3