From 98a672123c7872f6b9b75a9a2b6bb3aea504de6a Mon Sep 17 00:00:00 2001 From: David Leutgeb Date: Tue, 5 Dec 2023 12:25:34 +0100 Subject: Initial commit --- MIBS/allied/AT-QOS-MIB | 875 +++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 875 insertions(+) create mode 100644 MIBS/allied/AT-QOS-MIB (limited to 'MIBS/allied/AT-QOS-MIB') diff --git a/MIBS/allied/AT-QOS-MIB b/MIBS/allied/AT-QOS-MIB new file mode 100644 index 0000000..c64cd2c --- /dev/null +++ b/MIBS/allied/AT-QOS-MIB @@ -0,0 +1,875 @@ +-- ============================================================================ +-- AT-QOS.MIB, Allied Telesis enterprise MIB: Quality Of Service module +-- +-- Copied from ATR-QOS.MIB of pre 2.9.1 release +-- +-- Copyright (c) 2006 by Allied Telesis, Inc. +-- All rights reserved. +-- +-- ============================================================================ + +AT-QOS-MIB DEFINITIONS ::= BEGIN + +IMPORTS + MODULE-IDENTITY, + OBJECT-TYPE, + Counter32, + Counter64, + Integer32, + Gauge32 + FROM SNMPv2-SMI + + DisplayString + FROM SNMPv2-TC + + modules + FROM AT-SMI-MIB +; + +qos MODULE-IDENTITY + LAST-UPDATED "200412011525Z" + ORGANIZATION "Allied Telesis, Inc" + CONTACT-INFO + "http://www.alliedtelesis.com" + DESCRIPTION + "This MIB file contains definitions of managed objects for the + handling QoS on Allied Telesis switches. There are a + number of tables designed to be generic to + all ATR switches supporting QoS in silicon, and well as tables for + specific AT switches or switch familes." + + REVISION "200412011525Z" +DESCRIPTION + "Initial Revision" + +::= { modules 99 } + +-- ============================================================================ +-- ============================================================================ +-- QoS Switch group +-- ============================================================================ +-- ============================================================================ + +qosSwitch OBJECT IDENTIFIER ::= { qos 1 } + +-- ================================================= +-- QoS Switch Port table +-- ================================================= + +qosSwitchPortTable OBJECT-TYPE + SYNTAX SEQUENCE OF QosSwitchPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Generic port configuration for QoS, indexed by port index." + ::= { qosSwitch 1 } + +qosSwitchPortEntry OBJECT-TYPE + SYNTAX QosSwitchPortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A single switch port entry for QoS." + INDEX { qosSwitchPortIndex } + ::= { qosSwitchPortTable 1 } + +QosSwitchPortEntry ::= + SEQUENCE { + qosSwitchPortIndex + Integer32, + qosSwitchPortPolicyIndex + Integer32 + } + +qosSwitchPortIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Port index of the port entry. This index is the same port number + used in CLI commands, and the same index as appears in other MIB + tables related to switch ports." + ::= { qosSwitchPortEntry 1 } + +qosSwitchPortPolicyIndex OBJECT-TYPE + SYNTAX Integer32 (1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Policy index of the policy for this port. Policy index numbers for + CLI commands start at 0, while SNMP indexes must start at 1. This + means that the policy index in this MIB variable is 1 more than the + index for the same policy as entered for CLI commands." + ::= { qosSwitchPortEntry 2 } + +-- ============================================================================ +-- Policy table +-- ============================================================================ + +qosSwitchPolicyTable OBJECT-TYPE + SYNTAX SEQUENCE OF QosSwitchPolicyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "QoS policy configuration, indexed by policy index." + ::= { qosSwitch 2 } + +qosSwitchPolicyEntry OBJECT-TYPE + SYNTAX QosSwitchPolicyEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A policy entry containing configuration information for + a single policy." + INDEX { qosSwitchPolicyIndex } + ::= { qosSwitchPolicyTable 1 } + +QosSwitchPolicyEntry ::= + SEQUENCE { + qosSwitchPolicyIndex + Integer32, + qosSwitchPolicyDescription + OCTET STRING, + qosSwitchPolicyDefaultTCDropBWClass3 + INTEGER, + qosSwitchPolicyDefaultTCIgnoreBWClass + INTEGER, + qosSwitchPolicyDefaultTCMarkValue + Integer32, + qosSwitchPolicyDefaultTCMaxBandwidth + Integer32, + qosSwitchPolicyDefaultTCMaxBurstSize + Integer32, + qosSwitchPolicyDefaultTCMinBandwidth + Integer32, + qosSwitchPolicyDefaultTCMinBurstSize + Integer32, + qosSwitchPolicyDefaultTCPremarking + INTEGER, + qosSwitchPolicyDefaultTCRemarking + INTEGER + } + +qosSwitchPolicyIndex OBJECT-TYPE + SYNTAX Integer32 (1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of this policy entry. Policy index numbers for + CLI commands start at 0, while SNMP indexes must start at 1. This + means that the policy index in this MIB variable is 1 more than the + index for the same policy as entered for CLI commands." + ::= { qosSwitchPolicyEntry 1 } + +qosSwitchPolicyDescription OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An optional description for the policy, as entered via the CLI." + ::= { qosSwitchPolicyEntry 2 } + +qosSwitchPolicyDefaultTCDropBWClass3 OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether traffic that exceeds the bandwidth for the + default traffic class be dropped or not. The bandwidth limit is the + combined total of the variables qosSwitchPolicyDefaultTCMaxBandwidth + and qosSwitchPolicyDefaultTCMaxBurstSize. A value of yes(1) indicates + that traffic exceeding the bandwidth limit is dropped immediately. A + value of no(0) indicates that the excess traffic is marked as + bandwidth class 3 and is therefore eligible for dropping by the RED + curve settings." + ::= { qosSwitchPolicyEntry 3 } + +qosSwitchPolicyDefaultTCIgnoreBWClass OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether the traffic metering stage acknowledges any + bandwidth class assigned to flows processed by the default traffic + class. If set to yes(1), previously assigned bandwidth classes will + be ignored will be ignored and the bandwidth class of the traffic + will be set according to the meter conformance level of the flow." + ::= { qosSwitchPolicyEntry 4 } + +qosSwitchPolicyDefaultTCMarkValue OBJECT-TYPE + SYNTAX Integer32 (0..63 | 256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When the qosSwitchPolicyDefaultTCPremarking variable is set to + usemarkvalue(1), this variable specifies the index into the DSCP + MAP table to use for remarking. A value in the range 0 to 63 + indicates the DSCP to use, the value 256 indicates that no DSCP + value has been defined for the default traffic class for this policy." + ::= { qosSwitchPolicyEntry 5 } + +qosSwitchPolicyDefaultTCMaxBandwidth OBJECT-TYPE + SYNTAX Integer32 (0..16000000 | 2147483647) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum bandwidth available to the default traffic + class. Traffic under this bandwidth will be designated as bandwidth + class 2. The value 2147483647 indicates that there is no limit on + the maximum bandwidth for the default traffic class for this + policy." + ::= { qosSwitchPolicyEntry 6 } + +qosSwitchPolicyDefaultTCMaxBurstSize OBJECT-TYPE + SYNTAX Integer32 (0..16000000) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum bandwidth above the bandwidth specified by + qosSwitchPolicyDefaultTCMaxBandwidth before traffic is marked as + bandwidth class 3." + ::= { qosSwitchPolicyEntry 7 } + +qosSwitchPolicyDefaultTCMinBandwidth OBJECT-TYPE + SYNTAX Integer32 (0..16000000 | 2147483647) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the minimum bandwidth reserved for the default traffic + class. Traffic under this bandwidth will be marked as bandwidth + class 1. The value 2147483647 indicates that there is no limit on + the minimum bandwidth for the default traffic class for this + policy." + ::= { qosSwitchPolicyEntry 8 } + +qosSwitchPolicyDefaultTCMinBurstSize OBJECT-TYPE + SYNTAX Integer32 (0..16000000) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum amount of data above the bandwidth specified + in the variable qosSwitchPolicyDefaultTCMinBandwidth before traffic + is marked as bandwidth class 2." + ::= { qosSwitchPolicyEntry 9 } + +qosSwitchPolicyDefaultTCPremarking OBJECT-TYPE + SYNTAX INTEGER { + none(0), + usemarkvalue(1), + usedscp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the QoS action to take on traffic in the default traffic + class before metering actions are taken. If none(0) is specified, + the traffic is passed to the metering stage. If usemarkvalue(1) is + specified, the QoS settings are taken from the variable + qosSwitchPolicyDefaultTCMarkValue used as an index into the DCSP + MAP table. If usedscp(2) is specified, the DSCP value in the data + frames is used as an index into the DSCP MAP table." + ::= { qosSwitchPolicyEntry 10 } + +qosSwitchPolicyDefaultTCRemarking OBJECT-TYPE + SYNTAX INTEGER { + none(0), + usedscpmap(1), + bwclass(2), + priority(3), + bwclass_priority(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the action to take after the metering stage for traffic + in the default traffic class. The metering stage assigns a + temporary value of bandwidth class to the flow which is used to + determine its per-hop behaviour. If this variable is set to + bwclass(2) or bwclass_priority(4), the temporary bandwidth class + becomes the new bandwidth class for the flow. If priority(3) or + bwclass_priority(4) is specified, the currently + assigned queue for frames in this traffic class is used in + conjunction with the temporary bandwidth class to determine the new + value of the VLAN Tag User Priority field. If usedscpmap(1) is + specified, the temporary value is used (in conjunction with the + DSCP of the frame) as an index into the DSCP MAP table, which then + assigns the actual, new values for bandwidth class, DSCP, Egress + Queue and VLAN Tag User Priority. A value of none(0) for this + variable means that no remarking of the packet is done after the + metering stage." + ::= { qosSwitchPolicyEntry 11 } + +-- ============================================================================ +-- Traffic Class table +-- ============================================================================ + +qosSwitchTrafficClassTable OBJECT-TYPE + SYNTAX SEQUENCE OF QosSwitchTrafficClassEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Traffic class configuration, indexed by traffic class index." + ::= { qosSwitch 3 } + +qosSwitchTrafficClassEntry OBJECT-TYPE + SYNTAX QosSwitchTrafficClassEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A traffic class entry containing configuration information for + a single traffic class." + INDEX { qosSwitchTrafficClassIndex } + ::= { qosSwitchTrafficClassTable 1 } + +QosSwitchTrafficClassEntry ::= + SEQUENCE { + qosSwitchTrafficClassIndex + Integer32, + qosSwitchTrafficClassPolicyNumber + Integer32, + qosSwitchTrafficClassDescription + OCTET STRING, + qosSwitchTrafficClassDropBWClass3 + INTEGER, + qosSwitchTrafficClassIgnoreBWClass + INTEGER, + qosSwitchTrafficClassMarkValue + Integer32, + qosSwitchTrafficClassMaxBandwidth + Integer32, + qosSwitchTrafficClassMaxBurstSize + Integer32, + qosSwitchTrafficClassMinBandwidth + Integer32, + qosSwitchTrafficClassMinBurstSize + Integer32, + qosSwitchTrafficClassPremarking + INTEGER, + qosSwitchTrafficClassRemarking + INTEGER + } + +qosSwitchTrafficClassIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of this traffic class entry. Traffic class index numbers + for CLI commands start at 0, while SNMP indexes must start at 1. + This means that the traffic class index in this MIB variable is 1 + more than the index for the same traffic class as entered for CLI + commands." + ::= { qosSwitchTrafficClassEntry 1 } + +qosSwitchTrafficClassPolicyNumber OBJECT-TYPE + SYNTAX Integer32 (0..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Policy index of the policy to which this traffic class belongs. + Policy index numbers for CLI commands start at 0, while SNMP + indexes must start at 1. This means that the policy index in this + MIB variable is 1 more than the index for the same policy as + entered for CLI commands. A value of 0 for this variable means + that the traffic class has not been added to a policy yet." + ::= { qosSwitchTrafficClassEntry 2 } + +qosSwitchTrafficClassDescription OBJECT-TYPE + SYNTAX OCTET STRING (SIZE (0..15)) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "An optional description for this traffic class." + ::= { qosSwitchTrafficClassEntry 3 } + +qosSwitchTrafficClassDropBWClass3 OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether traffic that exceeds the bandwidth for + this traffic class be dropped or not. The bandwidth limit is the + combined total of the variables qosSwitchTrafficClassMaxBandwidth + and qosSwitchTrafficClassMaxBurstSize A value of yes(1) indicates + that traffic exceeding the bandwidth limit is dropped immediately. A + value of no(0) indicates that the excess traffic is marked as + bandwidth class 3 and is therefore eligible for dropping by the RED + curve settings." + ::= { qosSwitchTrafficClassEntry 4 } + +qosSwitchTrafficClassIgnoreBWClass OBJECT-TYPE + SYNTAX INTEGER { + no(0), + yes(1) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies whether the traffic metering stage acknowledges any + bandwidth class assigned to flows processed by this traffic + class. If set to yes(1), previously assigned bandwidth classes will + be ignored will be ignored and the bandwidth class of the traffic + will be set according to the meter conformance level of the flow." + ::= { qosSwitchTrafficClassEntry 5 } + +qosSwitchTrafficClassMarkValue OBJECT-TYPE + SYNTAX Integer32 (0..63 | 256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "When the qosSwitchTrafficClassPremarking variable is set to + usemarkvalue(1), this variable specifies the index into the DSCP + MAP table to use for remarking. A value in the range 0 to 63 + indicates the DSCP to use, the value 256 indicates that no DSCP + value has been defined for this traffic class." + ::= { qosSwitchTrafficClassEntry 6 } + +qosSwitchTrafficClassMaxBandwidth OBJECT-TYPE + SYNTAX Integer32 (0..16000000 | 2147483647) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum bandwidth available to this traffic + class. Traffic under this bandwidth will be designated as bandwidth + class 2. The value 2147483647 indicates that there is no limit on + the maximum bandwidth for this traffic class." + ::= { qosSwitchTrafficClassEntry 7 } + +qosSwitchTrafficClassMaxBurstSize OBJECT-TYPE + SYNTAX Integer32 (0..16000000) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum bandwidth above the bandwidth specified by + qosSwitchTrafficClassMaxBandwidth before traffic is marked as + bandwidth class 3." + ::= { qosSwitchTrafficClassEntry 8 } + +qosSwitchTrafficClassMinBandwidth OBJECT-TYPE + SYNTAX Integer32 (0..16000000 | 2147483647) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the minimum bandwidth reserved for this traffic + class. Traffic under this bandwidth will be marked as bandwidth + class 1. The value 2147483647 indicates that there is no limit on + the minimum bandwidth for this traffic class." + ::= { qosSwitchTrafficClassEntry 9 } + +qosSwitchTrafficClassMinBurstSize OBJECT-TYPE + SYNTAX Integer32 (0..16000000) + UNITS "kbps" + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the maximum amount of data above the bandwidth specified + in the variable qosSwitchTrafficClassMinBandwidth before traffic + is marked as bandwidth class 2." + ::= { qosSwitchTrafficClassEntry 10 } + +qosSwitchTrafficClassPremarking OBJECT-TYPE + SYNTAX INTEGER { + none(0), + usemarkvalue(1), + usedscp(2) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the QoS action to take on traffic in this traffic + class before metering actions are taken. If none(0) is specified, + the traffic is passed to the metering stage. If usemarkvalue(1) is + specified, the QoS settings are taken from the variable + qosSwitchTrafficClassMarkValue used as an index into the DCSP + MAP table. If usedscp(2) is specified, the DSCP value in the data + frames is used as an index into the DSCP MAP table." + ::= { qosSwitchTrafficClassEntry 11 } + +qosSwitchTrafficClassRemarking OBJECT-TYPE + SYNTAX INTEGER { + none(0), + usedscpmap(1), + bwclass(2), + priority(3), + bwclass_priority(4) + } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Specifies the action to take after the metering stage for traffic + in this traffic class. The metering stage assigns a + temporary value of bandwidth class to the flow which is used to + determine its per-hop behaviour. If this variable is set to + bwclass(2) or bwclass_priority(3), the temporary bandwidth class + becomes the new bandwidth class for the flow. If priority(3) or + bwclass_priority(4) is specified, the currently + assigned queue for frames in this traffic class is used in + conjunction with the temporary bandwidth class to determine the new + value of the VLAN Tag User Priority field. If usedscpmap(1) is + specified, the temporary value is used (in conjunction with the + DSCP of the frame) as an index into the DSCP MAP table, which then + assigns the actual, new values for bandwidth class, DSCP, Egress + Queue and VLAN Tag User Priority. A value of none(0) for this + variable means that no remarking of the packet is done after the + metering stage." + ::= { qosSwitchTrafficClassEntry 12 } + +-- ============================================================================ +-- ============================================================================ +-- 8948 specific stuff. The tables in this section are specific to the 8948 +-- switch, because they relate directly to the hardware used in this switch. +-- Other switches that use the same hardware will also support this MIB table. +-- ============================================================================ +-- ============================================================================ + +qosSwitch8948 OBJECT IDENTIFIER ::= { qosSwitch 4 } + +-- ============================================================================ +-- 8948 port table - 8948 specific extensions to the qosSwitchPortTable +-- ============================================================================ + +qosSwitch8948PortTable OBJECT-TYPE + SYNTAX SEQUENCE OF QosSwitch8948PortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Port configuration, indexed by port index." + ::= { qosSwitch8948 1 } + +qosSwitch8948PortEntry OBJECT-TYPE + SYNTAX QosSwitch8948PortEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A single switch port entry." + AUGMENTS { qosSwitchPortEntry } + ::= { qosSwitch8948PortTable 1 } + +QosSwitch8948PortEntry ::= + SEQUENCE { + qosSwitch8948PortDefaultTCCountersAggregateBytes + Counter64, + qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes + Counter64, + qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes + Counter64, + qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes + Counter64, + qosSwitch8948PortDefaultTCCountersDroppedBytes + Counter64, + qosSwitch8948PortQueueLength + Gauge32, + qosSwitch8948PortQueue0Length + Gauge32, + qosSwitch8948PortQueue1Length + Gauge32, + qosSwitch8948PortQueue2Length + Gauge32, + qosSwitch8948PortQueue3Length + Gauge32, + qosSwitch8948PortQueue4Length + Gauge32, + qosSwitch8948PortQueue5Length + Gauge32, + qosSwitch8948PortQueue6Length + Gauge32, + qosSwitch8948PortQueue7Length + Gauge32 + } + +qosSwitch8948PortDefaultTCCountersAggregateBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of bytes classified by the default traffic class + on this port." + ::= { qosSwitch8948PortEntry 1 } + +qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by the default traffic class on + this port conforming to bandwidth class 1." + ::= { qosSwitch8948PortEntry 2 } + +qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by the default traffic class on + this port conforming to bandwidth class 2." + ::= { qosSwitch8948PortEntry 3 } + +qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by the default traffic class on + this port conforming to bandwidth class 3." + ::= { qosSwitch8948PortEntry 4 } + +qosSwitch8948PortDefaultTCCountersDroppedBytes OBJECT-TYPE + SYNTAX Counter64 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes dropped by the default traffic class on + this port." + ::= { qosSwitch8948PortEntry 5 } + +qosSwitch8948PortQueueLength OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of packets currently queued for transmission on + this port." + ::= { qosSwitch8948PortEntry 6 } + +qosSwitch8948PortQueue0Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 0. + The numbering of queues indicates the priority of handling the + traffic in that queue, with the higher queue number getting + higher priority. The priority values in packets are mapped to + queues via a priority to queue mapping. The default priority to + queue mapping is as follows: + Priority Queue + value number + 7 7 + 6 6 + 5 5 + 4 4 + 3 3 + 2 1 + 1 0 + 0 2 + This mapping allows the default priority value of 0 to map to a + queue which is not the lowest priority queue, allowing traffic + classes to be assigned a lower priority queue than the default." + ::= { qosSwitch8948PortEntry 7 } + +qosSwitch8948PortQueue1Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 1. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 8 } + +qosSwitch8948PortQueue2Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 2. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 9 } + +qosSwitch8948PortQueue3Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 3. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 10 } + +qosSwitch8948PortQueue4Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 4. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 11 } + +qosSwitch8948PortQueue5Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 5. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 12 } + +qosSwitch8948PortQueue6Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 6. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 13 } + +qosSwitch8948PortQueue7Length OBJECT-TYPE + SYNTAX Gauge32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of packets currently queued for transmission on this + port in queue 7. See the description for qosSwitch8948PortQueue0Length + to understand the meaning of queue numbers." + ::= { qosSwitch8948PortEntry 14 } + +-- ============================================================================ +-- Traffic Class counters table +-- ============================================================================ + +qosSwitch8948TrafficClassCountersTable OBJECT-TYPE + SYNTAX SEQUENCE OF QosSwitch8948TrafficClassCountersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Traffic class counters indexed by port, policy and traffic + class." + ::= { qosSwitch8948 2 } + +qosSwitch8948TrafficClassCountersEntry OBJECT-TYPE + SYNTAX QosSwitch8948TrafficClassCountersEntry + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A traffic class counters entry containing QOS counters for a + particular port, policy and traffic class." + INDEX { qosSwitch8948TCCountersPortIndex, + qosSwitch8948TCCountersPolicyIndex, + qosSwitch8948TCCountersTrafficClassIndex } + ::= { qosSwitch8948TrafficClassCountersTable 1 } + +QosSwitch8948TrafficClassCountersEntry ::= + SEQUENCE { + qosSwitch8948TCCountersPortIndex + Integer32, + qosSwitch8948TCCountersPolicyIndex + Integer32, + qosSwitch8948TCCountersTrafficClassIndex + Integer32, + qosSwitch8948TCCountersAggregateBytes + Counter32, + qosSwitch8948TCCountersBwConformanceClass1Bytes + Counter32, + qosSwitch8948TCCountersBwConformanceClass2Bytes + Counter32, + qosSwitch8948TCCountersBwConformanceClass3Bytes + Counter32, + qosSwitch8948TCCountersDroppedBytes + Counter32 + } + +qosSwitch8948TCCountersPortIndex OBJECT-TYPE + SYNTAX Integer32 (0..2147483647) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the port for this entry in the traffic class + counter table. This index is the same as the port index in the + port table and is the same as the port number of the port in + user commands." + ::= { qosSwitch8948TrafficClassCountersEntry 1 } + +qosSwitch8948TCCountersPolicyIndex OBJECT-TYPE + SYNTAX Integer32 (1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the policy for this entry in the traffic class + counter table. Each port can only have one policy assigned at a + time. Policy index numbers for CLI commands start at 0, while SNMP + indexes must start at 1. This means that the policy index in this + MIB variable is 1 more than the index for the same policy as + entered for CLI commands." + ::= { qosSwitch8948TrafficClassCountersEntry 2 } + +qosSwitch8948TCCountersTrafficClassIndex OBJECT-TYPE + SYNTAX Integer32 (1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The index of the traffic class for this entry in the traffic + class counter table. The index is one of the indices defined for + traffic classes for this port and policy. Traffic class indices + for CLI commands start at 0, while SNMP indices must start at 1. + This means that the traffic class index in this MIB variable is 1 + more than the index for the same traffic class as entered for CLI + commands." + ::= { qosSwitch8948TrafficClassCountersEntry 3 } + +qosSwitch8948TCCountersAggregateBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The total number of bytes classified by this traffic class for + this policy on this port." + ::= { qosSwitch8948TrafficClassCountersEntry 4 } + +qosSwitch8948TCCountersBwConformanceClass1Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by this traffic class for this + policy on this port conforming to bandwidth class 1." + ::= { qosSwitch8948TrafficClassCountersEntry 5 } + +qosSwitch8948TCCountersBwConformanceClass2Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by this traffic class for this + policy on this port conforming to bandwidth class 2." + ::= { qosSwitch8948TrafficClassCountersEntry 6 } + +qosSwitch8948TCCountersBwConformanceClass3Bytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes classified by this traffic class for this + policy on this port conforming to bandwidth class 3." + ::= { qosSwitch8948TrafficClassCountersEntry 7 } + +qosSwitch8948TCCountersDroppedBytes OBJECT-TYPE + SYNTAX Counter32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of bytes dropped by this traffic class for this + policy on this port." + ::= { qosSwitch8948TrafficClassCountersEntry 8 } + +END -- cgit v1.2.3